Refrigerator Features

Door Open Alarm

Door open alarm sounds and indicator light blinks if either door is open for more than 3 minutes.

• Deactivate door open alarm by pressing

Alarm Off pad or by closing either door.

• Activate door open alarm by pressing

Display On pad then holding

Alarm Off pad for 3 to 5 seconds. Three short beeps indicate instructions were accepted.

High Temperature Alarm

High temperature alarm sounds and indicator light glows if refrigerator or freezer temperature is high for 2 hours. A blinking light signals affected compartment. Alarm ends when proper temperature is reached.

• Deactivate high temperature alarm by pressing Alarm

Off pad.

Thermistor Alarm

Thermistor electronically senses refrigerator and freezer temperatures. Thermistor alarm sounds and indicator lights scroll if refrigerator or freezer thermistor is not operating properly.

• Deactivate display by pressing Alarm Off pad.

If thermistor alarm sounds, contact an authorized

Amana technician immediately. If

Alarm Off pad is pressed, thermistor control retests to confirm situation has been corrected. Alarm sounds again if thermistor is still not operating properly. Alarm can be reset by turning power disconnect switch to off position and turning back to on position.

Display Lights

• Deactivate temperature display lights by pressing

Display On pad then pressing Display Off pad.

• Activate temperature display lights by pressing

Display On pad.

Setting Controls

Set controls precisely with a household thermometer that includes temperatures between -5° to 50°F

(-21° to 10°C).

Put thermometer snugly between frozen packages in freezer section. Wait 5-8 hours. If freezer temperature is not 0° to 2°F (-17° to -16°C), adjust control, 1 number at a time. Check again after 5-8 hours.

Put thermometer in a glass of water in middle of refrigerator section. Wait 5-8 hours. If refrigerator temperature is not 38° to 40°F (3° to 4°C), adjust control,

1 number at a time. Check again after 5-8 hours.

Water Filtration System

The Amana

®

Clean ‘n Clear

water filtration system provides water treatment with a revolutionary 2-stage design. Refer to Clean ‘n Clear

water filtration system installation and operating instructions.

Spillsaver

Shelves

!

CAUTION

To avoid personal injury and property damage, confirm shelf is secure before placing items on shelf.

Spillsaver ™ shelves are constructed of polypropylene molded around the glass and metal rail. Therefore,

Spillsaver ™ shelves are completely encapsulated and liquids cannot seep under the glass. This localizes spills and provides easier cleaning. Spillsaver ™ shelves also adjust to meet individual storage needs.

!

CAUTION

To avoid personal injury or property damage, handle tempered glass shelves carefully. Shelves may break suddenly if nicked, scratched, or exposed to sudden temperature change.

• Remove shelves by lifting front, releasing hooks from metal track then pulling out.

• Replace shelves by inserting hooks into metal track and lowering front.