The pin configuration of the optional D-Sub 25-pin female connector is given below.
Parameter [012] is set to
“0” or “1” is set to “2”
Pin no. for desk and panel types
(D-Sub, 25-pin, female)
Pin no. for stainless steel housing
J10 connector
(Option 1)
JR1 / JR2 connector
(Option 2 or 3)
TxD1; Par. [01-]
RxD1; Par. [01-]
TxD2; Par. [02-] RTS1; Par. [01-]
RxD2; Par. [02-] CTS1; Par. [01-]
2
3
4
5
8
7
3
2
15
14
10
9
GND (RS 232C)
R-; Par. [02-]
R+; Par. [02-]
T+; Par. [02-]
+V; Par. [02-]
Termination (RS 485)
Termination (RS 485)
7
8
9
10
11
19
20
6-9
Not used
Not used
Not used
Not used
Not used
Not used
13
A; Par. [02-]
B; Par. [02-]
T-; Par. [02-]
+24V; 20 mA CL
21
22
24
25
5
4
Not used
Not used
12
11
Shield D25 body 1 1
The RS485 interface termination can be done by short circuiting pin no. 19 and 20 at the desk and panel type enclosures or by jumper JP4 on the interface board within the stainless steel housing . These short circuits terminate the line with an internal termination resistor of 100
Ω.
The 20mA CL ASCII output is disabled by default. The connections should be made as given in figure 9.1 for enabling this output. (Enabled output is not available for 12 V DC instruments ).
25
11
10
24
9
FT-1x
8
Figure 9.1 20 mA CL ASCII interface connection
9.2.3 Continuous Output Mode
The continuous output mode allows for a fast and continuous data export to connected peripheral devices. The output data structure is described in Appendix 2.
9.2.4 Host Mode
The indicator can communicate with a PC in host mode. You can upload or download data to the indicator by adjusting the related interface parameters within the FLINTEC IndFace software or using the command sets described in Appendix 3. This mode is convenient for process control applications which need not only the weight data, but also require some uploads / downloads and status control.
9.2.5 Print Mode
In the print mode you can select the print formats (parameter group [04-], see chapter 9.2.6). This format
– preferably the single line
– is convenient to use as weight data interface in legal for trade applications which require recording to the Alibi memory. The print mode is not available for more than one interface (see also overview in chapter 9.1).
FT-12 Technical Manual, Rev. 1.35 November 2010
Page 23 of 44
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 4 Safety Instructions
- 5 Declaration of Conformity
- 6 Overview
- 6 Key Features
- 6 Available Options and Accessoires
- 7 Technical Specifications
- 8 Housing Dimensions
- 8 Desk Type Housing
- 8 Stainless Steel Housing
- 9 Panel Type Housing
- 10 Installation and Commissioning
- 10 Mechanical Installation
- 10 Jumpers
- 10 Electrical Connections
- 10 Power Supply and Grounding
- 11 Standard Load Cell Connection
- 11 Commissioning
- 12 Front Panel and Keypad
- 12 Weight Display and Status LEDs
- 13 Keypad
- 13 Key lock
- 14 Setup and Calibration
- 14 Basics
- 14 Basic Setup Keys on the Frontplate
- 14 Entering the Setup and Calibration Menu
- 14 Exiting the Setup and Calibration Menu
- 15 Application Programmes
- 15 Basic Weighing
- 15 Check Weighing
- 15 Peak Hold
- 16 Dynamic Weighing
- 16 Filling
- 16 Setup
- 17 Configuration Parameters
- 17 Scale Parameters
- 19 Scale Calibration
- 20 Memory Operations
- 20 ID Memory
- 20 Preset Tare Memory
- 20 Setpoint Memory
- 21 Alibi Memory and Legal Metrological Records
- 22 Communication
- 22 Overview about Communication
- 22 Serial Interface and Printer
- 22 Standard Serial Interface Connector (RS232C)
- 22 Optional Serial Interface Connector (RS232C, RS485, 20 mA TTY)
- 23 Continuous Output Mode
- 23 Host Mode
- 23 Print Mode
- 24 Setup
- 27 Ethernet Option
- 27 Electrical Connections
- 27 Setup
- 29 Data Structure
- 30 Other I/O Options
- 30 Analogue Output Option
- 30 Electrical Connections
- 30 Setup
- 31 Digital I/O Option
- 31 Electrical Connections
- 31 Setup
- 32 Entering Setpoints
- 32 Binary Output Option
- 33 Diagnostics
- 34 Appendix 1: Setup and Calibration Menus
- 35 Appendix 2: Continues Output Mode Data Structure
- 36 Appendix 3: Host Mode Data Structure
- 39 Appendix 4: Modbus RTU Data Structure
- 42 Appendix 5: Error Table
- 43 Appendix 6: Parameter’s Default Table
- 44 Appendix 7: Calibration Table