7�4 Installation of the unit with single probe. IFM LR2050

Add to My manuals
45 Pages

advertisement

7�4  Installation of the unit with single probe. IFM LR2050 | Manualzz

► Remove fastening bracket and centring piece (A, B)�

► Shorten the coaxial pipe to the requested length: L

K

= L + 9 mm�

► After shortening, at least one hole

(C) for insertion of the fixing bracket has to be left�

► Remove all burrs and sharp edges�

► Insert centring piece (A) at the lower end of the pipe and attach it using the fixing bracket (B) at the lower hole (C)�

A

B

C

L

K

= length of the coaxial pipe

L = length of the rod from the lower edge of the process connection

7.4 Installation of the unit with single probe

Before installing and removing the unit: Make sure that no pressure is applied to the system and that there is no medium in the tank that could leak� Also always note the potential dangers related to extreme machine and medium temperatures�

For installation in closed metal tanks, the tank lid serves as a launching plate) (→

5�1)�

Options are as follows:

• Screw into a G¾ process connection directly in the tank lid (for tanks with thick walls)�

• Installation in the tank lid using a flange plate (for tanks with thin walls)�

During installation of the process connection on the tank side observe the subsequent orientation of the housing (display orientation, cable outlet)�

The sensor housing cannot be rotated with respect to the internal thread�

Subsequent alignment of the sensor housing is therefore not possible�

Furthermore, installation in open tanks (→ 7.4.1) and plastic tanks is

possible (→ 7.4.2).

22

advertisement

Key Features

  • Guided wave radar
  • Tank adjustment
  • 2 Outputs: switching & analog
  • IO-Link function
  • High temp range
  • Adjustable damping

Related manuals

Frequently Answers and Questions

What type of media can be detected?
The LR2050 can detect aqueous media, oils, and oil-based media (for operations with coaxial probe).
What are the minimum installation distances?
For single probe operations, the minimum distances to tank walls, objects, and the tank bottom must be adhered to. Refer to the manual for specific distances.
How does tank adjustment work?
Tank adjustment helps suppress interfering reflections by entering an adjustment distance. This helps improve signal quality in challenging conditions.
How can I configure the analogue output?
You can configure the output function, start and end point for the analogue signal via the unit’s menu.
What are the switching functions available?
The device supports hysteresis and window functions for switching output, both in normally open and normally closed configurations.