METaL
ScREW 1/4
IncH LOnG
DRILL 1/8 IncH DIaMETER
HOLE. DO NOT pEnETRaTE
InnER LInER
Figure 19
Figure 20
used to support each elbow (Figure 10). Do not allow the elbows to support the weight of the vent pipe.
3. 90° Elbows. Figure 20. The installer should apply pressure to the section at the points indicated by the arrows. This will prevent the adjacent sections of the elbow from turning, as the next pipe or fitting is twistlocked on. This is important, because once these sections start rotating, the elbow does no longer have a 90° angle.
4. 45° Offsets with 90° Elbows. Figure 21 shows a 90° adjustable Elbow being utilized to accomplish a 45° offset. This Elbow is completely adjustable from 0° to 90°. please note that the centers of the upper sections tend to displace by a slight amount, as they are rotated. again, screws (not longer than
1/4”) may be used to secure the joint. Wall
Straps should also be utilized to enhance the stability of the vent system.
MALE AND FEMALE ADAPTERS
1. Description. The male and female adaptors enable an installer to connect
DuraVent B-vent components to an existing
Type B gas vent system manufactured by the following companies: american Metals products, Household Mfg, Hart & cooley Mfg,
Metal Fab, Inc, White Metal products, air Jet,
Mitchell Metal products.
2. Connecting into Existing Competitors
System. To connect into an existing competitors gas venting system from below, or from the appliance side, connect a Female adaptor as shown in Figure 22, insuring that the inner liner of the adaptor is outside the inner liner of the existing pipe. push the adaptor as far up as it will go, and tighten the locking bolt until the connection is snug.
3. Extending an Existing Competitors
System. To continue an existing competitors
12
NorthlineExpress.com
Figure 21
www.NorthlineExpress.com
Toll-Free 1-866-667-8454
advertisement
Related manuals
advertisement
Table of contents
- 4 Round B Vent, General Information, Planning
- 7 Steps for Typical Installations
- 11 Bucket Support
- 11 Combination Cap
- 12 Adjustable Elbows, Male and Female Adapters
- 13 Relining Masonry Chimneys for use with Gas Appliances
- 17 Troubleshooting
- 18 Maintenance
- 19 Oval B Vent, Installation Notes
- 22 4-Inch Oval Installation in 2x4 Inch Stud Walls
- 24 5-Inch Oval Installation in 2x4 Inch Stud Walls
- 26 6-Inch Oval Installation in 2x6 Inch Stud Walls