Option Description and Action
Other Known Device Manager
Servers
Access Gateways with Corrupt
Protected Resource Data
Access Gateways with Duplicate
Protected Resource Data
If a secondary Administration Console is in a non-reporting state, perhaps caused by hardware failure, its configuration needs to be removed from the primary Administration Console. As long as it is part of the configuration, other Access Manager devices try to contact it. If you cannot remove it by running the uninstall script on the secondary Administration Console, you can remove it by using this troubleshooting page. Click
Remove
next to the console that is in the non-reporting state. All references to the secondary Administration Console are removed from the configuration database.
If you modify the configuration for a protected resource, update the Access Gateway with the changes, then review the configuration for the protected resource and the changes have not been applied, the configuration for the protected resource is corrupted. Click
Repair
next to the protected resource that has a corrupted configuration. You should then be able to modify its configuration, and when you update the Access Gateway, the changes should be applied and saved.
After an upgrade, if you get errors related to invalid content for policy enforcement lists, you need to correct them. The invalid elements that do not have an associated resource data element are listed in this section. Click
Repair
.
Access Gateways with Protected
Resources Referencing
Nonexistent Policies
Protected resources have problems when policies are deleted before their references to the protected resources are removed. If you have protected resources in this condition, they are listed in this section. Click the
Repair
button to remove these references.
Then verify that your protected resources have the correct policies enabled. Click
Access Gateways
>
Edit
>
[Name of
Reverse Proxy]
>
[Name of Proxy Service]
>
Protected
Resources
, then change to the
Policy View
.
Access Gateways with Invalid Alert
Profile References
You can create XML validation errors on your Access Gateway
Appliance if you start to create an alert profile (click
Access
Gateways
>
Edit
>
Alerts
>
New
), but you do not finish the process. The incomplete alert profile does not appear in the configuration for the Access Gateway, so you cannot delete it. If such a profile exists, it appears in the
Access Gateways with
Invalid Alert Profile References
list. Click
Remove
. You should then be able to modify its configuration, and when you update the
Access Gateway, the changes should be applied and saved.
Devices with Corrupt Data Store
Entries
If an empty value is written to an XML attribute, the device with this invalid configuration appears in this list.
Click
Repair
to rewrite the invalid attribute values.
3
When you have finished repairing or deleting invalid Access Gateway configurations, click the
Access Gateways
link, then click
Update
>
OK
.
4
(Optional) Verify that all members of an Access Gateway cluster have the same configuration in cache:
4a
Click
Troubleshooting
>
Configuration
.
4b
Scroll to the
Cached Access Gateway Configuration
option.
4c
Click
View
next to the cluster configuration or next to an individual Access Gateway.