12. APPENDIX C - SAFETY AND CHARGING INSTRUCTIONS. Powerhouse PH2700PRi

Add to My manuals
46 Pages

advertisement

12. APPENDIX C - SAFETY AND CHARGING INSTRUCTIONS. Powerhouse PH2700PRi | Manualzz

12. APPENDIX C - SAFETY AND CHARGING INSTRUCTIONS

(a) SAVE THESE INSTRUCTIONS. THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING

INSTRUCTIONS.

(b) WORKING IN THE VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES GENERATE

EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS REASON IT IS OF THE

UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER, YOU READ AND

FOLLOW THE INSTRUCTIONS PROVIDED EXACTLY.

(c) TO REDUCE RISK OF BATTERY EXPLOSION, FOLLOW THESE INSTRUCTIONS AND THOSE

MARKED ON THE BATTERY.

(d) NEVER SMOKE OR ALLOW AN OPEN SPARK OR FLAME IN THE VICINITY OF THE BATTERY OR

ENGINE.

(e) USE CHARGER FOR CHARGING A LEAD-ACID BATTERY ONLY. IT IS NOT INTENDED TO SUPPLY

POWER TO AN EXTRA-LOW-VOLTAGE ELECTRICAL SYSTEM OR TO CHARGE DRY-CELL

BATTERIES. CHARGING DRY-CELL BATTERIES MAY CAUSE THEM TO BURST AND CAUSE

INJURY TO PERSONS AND DAMAGE TO PROPERTY.

(f) NEVER CHARGE A FROZEN BATTERY.

(g) IF IT IS NECESSARY TO REMOVE BATTERY FROM VEHICLE TO CHARGE IT, ALWAYS REMOVE

GROUNDED TERMINAL FROM BATTERY FIRST. MAKE SURE ALL ACCESSORIES IN THE VEHICLE

ARE OFF IN ORDER TO PREVENT AN ARC.

(h)

STUDY ALL BATTERY MANUFACTURER’S SPECIFIC PRECAUTIONS SUCH AS REMOVING OR

NOT REMOVING CELL CAPS WHILE CHARGING AND RECOMMENDED RATES OF CHARGE.

(i) FOR A CHARGER HAVING AN OUTPUT VOLTAGE SELECTOR SWITCH, REFER TO THE CAR

OWNER’S MANUAL IN ORDER TO DETERMINE THE VOLTAGE OF THE BATTERY AND TO MAKE

SURE THE OUTPUT VOLTAGE IS SET AT THE CORRECT VOLTAGE. IF AN OUTPUT VOLTAGE

SELECTOR SWITCH IS NOT PROVIDED, DO NOT USE THE BATTERY CHARGER UNLESS THE

BATTERY VOLTAGE MATCHES THE OUTPUT VOLTAGE RATING OF THE CHARGER.

(j) NEVER PLACE THE CHARGER DIRECTLY ABOVE OR BELOW THE BATTERY BEING CHARGED;

GASES OR FLUIDS FROM THE BATTERY WILL CORRODE AND DAMAGE THE CHARGER. LOCATE

THE CHARGER AS FAR AWAY FROM THE BATTERY AS DC CABLES PERMIT.

(k) DO NOT OPERATE CHARGER IN A CLOSED-IN AREA OR RESTRICT VENTILATION IN ANY WAY.

(l) CONNECT AND DISCONNECT DC OUTPUT CLIPS ONLY AFTER SETTING ANY CHARGER

SWITCHES TO THE OFF POSITION AND REMOVING AC CORD FROM THE ELECTRIC OUTLET.

NEVER ALLOW CLIPS TO TOUCH EACH OTHER.

(m) FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE. A SPARK NEAR BATTERY

MAY CAUSE A BATTERY EXPLOSION. TO REDUCE RISK OF A SPARK NEAR BATTERY:

i. POSITION AC AND DC CORDS TO REDUCE RISK OF DAMAGE BY HOOD, DOOR, OR

MOVING ENGINE PARTS;

ii. STAY CLEAR OF FAN BLADES, BELTS, PULLEYS, AND OTHER PARTS THAT CAN CAUSE

INJURY TO PERSONS;

iii. CHECK POLARITY OF BATTERY POSTS. A POSITIVE (POS, P, +) BATTERY POST USUALLY

HAS A LARGER DIAMETER THAN A NEGATIVE (NEG, N,

–) POST;

iv. DETERMINE WHICH POST OF BATTERY IS GROUNDED (CONNECTED) TO THE CHASSIS. IF

NEGATIVE POST IS GROUNDED TO CHASSIS (AS IN MOST VEHICLES), SEE ITEM (v). IF

POSITIVE POST IS GROUNDED TO THE CHASSIS, SEE ITEM (vi);

45 PH2700PRi OM

v. FOR A NEGATIVE-GROUNDED VEHICLE, CONNECT THE POSITIVE (RED) CLIP FROM

BATTERY CHARGER TO POSITIVE (POS, P, +) UNGROUNDED POST OF BATTERY.

CONNECT THE NEGATIVE (BLACK) CLIP TO VEHICLE CHASSIS OR ENGINE BLOCK AWAY

FROM BATTERY. DO NOT CONNECT CLIP TO CARBURETOR, FUEL LINES, OR

SHEET-METAL BODY PARTS. CONNECT TO A HEAVY GAUGE METAL PART OF THE FRAME

OR ENGINE BLOCK;

vi. FOR A POSITIVE-GROUNDED VEHICLE, CONNECT THE NEGATIVE (BLACK) CLIP FROM

BATTERY CHARGER TO NEGATIVE (NEG, N,

–) UNGROUNDED POST OF BATTERY.

CONNECT THE POSITIVE (RED) CLIP TO VEHICLE CHASSIS OR ENGINE BLOCK AWAY

FROM BATTERY. DO NOT CONNECT CLIP TO CARBURETOR, FUEL LINES, OR

SHEET-METAL BODY PARTS. CONNECT TO A HEAVY GAUGE METAL PART OF THE FRAME

OR ENGINE BLOCK;

vii. CONNECT CHARGER AC SUPPLY CORD TO ELECTRIC OUTLET; AND

viii. WHEN DISCONNECTING CHARGER, TURN SWITCHES TO OFF, DISCONNECT AC CORD,

REMOVE CLIP FROM VEHICLE CHASSIS, AND THEN REMOVE CLIP FROM BATTERY

TERMINAL.

(n) FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE. A SPARK NEAR THE BATTERY

MAY CAUSE A BATTERY EXPLOSION. TO REDUCE RISK OF A SPARK NEAR BATTERY:

i. CHECK POLARITY OF BATTERY POSTS. A POSITIVE (POS, P, +) BATTERY POST USUALLY

HAS A LARGER DIAMETER THAN A NEGATIVE (NEG, N,

–) POST;

ii. ATTACH AT LEAST A 60 CM 6-GAUGE (AWG) INSULATED BATTERY CABLE TO A NEGATIVE

(NEG, N,

–) BATTERY POST;

iii. CONNECT THE POSITIVE (RED) CHARGER CLIP TO THE POSITIVE (POS, P, +) POST OF

BATTERY;

iv. POSITION YOURSELF AND THE FREE END OF CABLE AS FAR AWAY FROM BATTERY AS

POSSIBLE, THEN CONNECT THE NEGATIVE (BLACK) CHARGER CLIP TO FREE END OF

CABLE;

v. DO NOT FACE BATTERY WHEN MAKING FINAL CONNECTION;

vi. CONNECT CHARGER AC SUPPLY CORD TO ELECTRICAL OUTLET; AND

vii. WHEN DISCONNECTING CHARGER, ALWAYS DO SO IN REVERSE SEQUENCE OF

CONNECTING PROCEDURE AND BREAK FIRST CONNECTION WHILE STANDING AS FAR

AWAY FROM BATTERY AS PRACTICAL.

(o) USE OF AN ADAPTER IS NOT ALLOWED IN CANADA. IF A GROUNDING TYPE RECEPTACLE IS

NOT AVAILABLE, DO NOT USE THIS APPLIANCE UNTIL THE PROPER OUTLET IS INSTALLED BY A

QUALIFIED ELECTRICIAN.

(p) THE GENERATOR (STATOR WINDING) IS ISOLATED FROM THE FRAME AND

FROM THE AC RECEPTACLE GROUND PIN.

(q) ELECTRICAL DEVICES THAT REQUIRE A GROUNDED RECEPTACLE PIN

CONNECTION WILL NOT FUNCTION IF THE RECEPTACLE GROUND PIN IS NOT

FUNCTIONAL.