INSTALLATION
STEP 11
FINISH INSTALL
1. Turn the release lever clockwise 180° back to the engaged position.
This engages the motor. The illustration shows the release lever in the engaged position.
2. Turn the key clockwise 180°. This locks the release lever. The operator is now engaged.
3. Fasten warning signs to the gate with cable ties. Warning signs
MUST be installed on both sides of the gate and in plain view.
Release Lever
Key
LIMIT AND FORCE ADJUSTMENT
ADJUSTMENT
To reduce the risk of SEVERE INJURY or DEATH:
• Without a properly installed safety reversal system, persons
(particularly small children) could be SERIOUSLY INJURED or
KILLED by a moving gate.
• Too much force on gate will interfere with proper operation of safety reversal system.
• NEVER increase force beyond minimum amount required to move gate.
• NEVER use force adjustments to compensate for a binding or sticking gate.
• If one control (force or travel limits) is adjusted, the other control may also need adjustment.
• After ANY adjustments are made, the safety reversal system MUST be tested. Gate MUST reverse on contact with a rigid object.
INTRODUCTION
Your operator is designed with electronic controls to make travel limit and force adjustments easy. The adjustments allow you to program where the gate will stop in the open and close position. The electronic controls sense the amount of force required to open and close the gate. The force is adjusted automatically when you program the limits but should be fine tuned using the REVERSAL FORCE dial on the control board (refer to Fine Tune the Force section) to compensate for environmental changes.
The limits can be set using the control board (following page) or a remote control (refer to Limit Setup with a Remote Control in the Appendix).
Setting the limits with a remote control requires a 3-button remote control programmed to OPEN, CLOSE, and STOP.
NOTE: The Test Buttons on the control board will not work until the limits have been set.
23
ADJUSTMENT
LIMIT AND FORCE ADJUSTMENT continued...
For dual gate applications the limits will have to be set for each operator. The gate MUST be attached to the operator before setting the limits and force.
INITIAL LIMITS AND FORCE ADJUSTMENT
If a mistake is made while programming the limits press the reset button to start over.
1. Set the GATE switch to the 1 position.
2. Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode.
3. Press and hold the MOVE GATE buttons to move the gate to the open or close limit.
4. Press and release the SET CLOSE or SET OPEN button depending on which limit is being set.
5. Press and hold the MOVE GATE button to move the gate to the other limit.
6. Press and release the SET CLOSE or SET OPEN button depending on which limit is being set. The operator will exit limit setting mode.*
7. Cycle the gate open and close using the TEST BUTTONS. This automatically sets the force.
8. For dual gates set the Gate switch to the 2 position and repeat steps
2-7.
When limits are set properly the operator will automatically exit limit setting mode.
*
Dual Gates ONLY: When the limits are set on the secondary gate first the control board will not exit the limit setting mode until the limits are set on the primary gate.
1
AGNOSTICS
CLOSE limit
SET OPEN
LED
LIMIT SETUP LEDS
SET CLOSE
LED
OPERATOR MODE EXPLANATION
OFF OFF NORMAL MODE Limits are set.
BLINKING BLINKING LIMIT SETTING MODE Limits are not set.
BLINKING ON LIMIT SETTING MODE Open limit is not set.
ON
ON
BLINKING LIMIT SETTING MODE Close limit is not set.
ON LIMIT SETTING MODE Limits are set.
DIAGNOSTICS
OPEN limit
2
7
3
DIAGNOSTICS
4
DIAGNOSTICS
6
5
24