YASKAWA Drive Software
Manuals and User Guides for YASKAWA Drive Software. We found 52 manuals for free downloads installation Guide, Manual, Technical manual, User manual
Below you will find brief information for YAI_Assy_70_71_20_21_EIP_Hz, YAI_Assy_70_71_22_23_EIP_Hz, YAI_Assy_70_71_101_EIP_Hz, YAI_Assy_70_71_116_EIP_Hz, YAI_Assy_72_73_20_21_EIP_Hz, YAI_Assy_72_73_22_23_EIP_Hz. This user guide assists in the configuration and application of Yaskawa Logix Add-On Instructions (AOI) for Logix Designer/RSLogix 5000. It facilitates the integration of Yaskawa drives into Rockwell Automation Logix environments by providing automatic tag generation for drive data, a single location to view controller-drive information, and features for test runs and troubleshooting.
Key Features
Automatic tag generation for drive data
Single location to view controller-drive information
Facilitates integration of Yaskawa drives into Logix environments
Supports Logix Designer/RSLogix 5000 v16 or later
Test run functionality for motor verification
Troubleshooting assistance for communication issues
Definable input and output assembly data
Comprehensive data tags for drive status and control
Pages: 22 YASKAWA Drive Software installation Guide
Brand: YASKAWA Category: Electrical equipment & supplies Size: 3 MB
Languages: English
Table of contents
Open manualOther manuals and documents
Frequently Answers and Questions
What software versions are required for Yaskawa AOI?
Yaskawa AOI requires Logix Designer or RSLogix 5000 version 16 or later.
How do I create a new tag for the AOI?
Right-click on the assigned tag name within the program, then select 'New [Tag Name]' to bring up the 'New Tag' window, confirm the information, and click create.
How do I assign input assembly data to the AOI?
Click the '?' next to 'Node_Input_Assy' on the AOI block to assign the input assembly data (from drive to PLC). Ensure the Yaskawa drive is added to the I/O configuration first.
Where can I find the correct AOI for my application?
Refer to the 'AOI Selection Table' in the user guide to choose the proper AOI based on your Input and Output Assemblies.
Can the AOI help with troubleshooting communication between the PLC and drive?
Yes, the AOI block displays the status of the AOI tags, showing commands issued to the drive and drive status information received, aiding in troubleshooting communications.
Questions & Answers
B B D
What configuration is required to run the drive forward and control speed via the network?
To run the drive forward, set the RunFwd bit high. For network speed control, ensure that network control is enabled (Net_Control bit activated when b1-02 ≠ 3) and network speed reference is enabled (Net_Ref bit activated when b1-03 ≠ 3).
A A O
What are the data tags automatically created or used by the Add-On Instruction (AOI)?
The term "subclass variables" is not explicitly defined. However, the AOI automatically generates tags for PLC logic, including: Control Commands (RunFwd, RunRev, FaultReset, Freq_Ref), Status and Feedback (Drive_State, Faulted, Ready, Running, RunningFwd, RunningRev, At_Speed, DC_Bus_Volt, Output_Current, Output_Freq), Assembly Inputs/Outputs (Node_Input_Assy, Node_Output_Assy), Custom Data Tags (Custom_In_1 to Custom_In_10, Custom_Out_1 to Custom_Out_10), and I/O Status. Users should strictly refer to the tag structures defined under the AOI Data Tag Description section.
advertisement