Yaskawa Drive Software Manual
YASKAWA V7 Drive: a versatile and high-performance solution for precise speed control in various industrial applications. With advanced features like classical precision winding, random winding, and pattern jump, it ensures high-quality package winding with minimal ribbons at high speeds. Its synchronous motors and identical accel/decel times for spindle and traverse drives maintain accurate speed ratios. The PLC-based control via Memobus broadcast commands offers flexibility and real-time adjustments.
Advertisement
Advertisement
A World of Automation Solutions
TM
CUSTOM SOFTWARE DESCRIPTION
TEXTILE FIBER WINDER
SOFTWARE
V7 Low HP (0.4 – 3.7 kW)
Software Number: VSP018070
Product: V7
Base Version: VSP0010024
Part Number: CIMR-V7AMXXXX-032
Release Date: 1/31/01 Author: Ty Phillips Beta Version
Overview: Frequency reference selection is added for winder ratio reference. Reference is written via a Memobus broadcast command, multiplied by a four digit numerator and divided by a four digit denominator. Support for Memobus function code 06H is added.
Revision History:
Date: 07/01/04, Rev: 04-07 Page 1 of 4 TM.V7SW.032L
Background and Application Information:
Traditional fiber winding uses one of several methods to control traverse motor speed: Classical precision winding, random winding, or pattern jump (also referred to as ribbon breaking).
In classical precision winding, the spindle and traverse motors are kept at a constant ratio, usually by mechanical gearing. This ratio is typically on the order of about three decimal places because more common ratios (integer or sub-integer) cause multiple wraps of thread to lay on top of each other, forming what is known as a “ribbon” defect. Classical precision winding produces the highest quality package, but has several drawbacks. Winders employing this technique cannot operate at high speeds due to mechanical limitations of the traverse guide. Also, these systems require several different stages of belting to achieve the unusual gear ratios, resulting in increased mechanical complexity.
Random winding permits much higher speeds because the traverse motor speed is held constant. Since the spindle motor speed is constantly changing the laying of the fibers appears random. However, the resulting package is not as dense as a precision wound package and tends to form ribbons.
Pattern jump, or ribbon breaking, has the high-speed benefits of random winding but produces a higher quality package. This method oscillates the traverse motor speed in a sawtooth fashion such that the motor speed will only briefly pass through “bad” ratio areas as the package diameter builds, reducing the number of ribbons. This is the method used in Yaskawa “P-jump” or “traverse” software.
This software is designed to electronically control the spindle and traverse drive output frequencies to run at a precise ratio. A PLC writes the frequency reference to both drives simultaneously via a Memobus broadcast command. Two parameters (changeable during run) are provided to ratio this speed reference. The PLC changes the traverse drive ratio parameters during operation via Memobus.
Synchronous motors are used so the commanded speeds are accurate. The spindle and traverse drives accel/decel times are programmed identically such that their output frequencies change at the same rate.
By periodically changing the speed ratio between the spindle and traverse drives, the “bad” ratios can be avoided. This method permits high-speed winding and creates a package that is close in quality to the classical precision wound package.
Fig. 1 – Diagram of Application
PLC
Traverse motor
M
M
Spindle motor
V7
Slave
V7
Master
Date: 07/01/04, Rev: 04-07 Page 2 of 4 TM.V7SW.032L
Additional Parameters:
No.
Memobus
No. Parameter Description Unit Setting Range Default
Access
Level n045 n046
012DH
012EH
Ratio Numerator
Ratio Denominator
-
-
1 ~ 9999
1 ~ 9999
1
1
1st function
1st function
Parameters n045 and n046 apply a ratio to the winder frequency reference.
Additional Reference Selection Setting:
Change
During
Run
Y
Y
Setting Description
10 Winder ratio reference
When n004 = 10, the inverter frequency reference will be given by the winder ratio reference.
Additional Memobus Register:
Memobus
No.
0004H
Parameter Description
Winder frequency reference
Unit
1 = 0.01Hz
This register is only accessible using a Memobus broadcast command (slave address 0), so no response message will be sent to the master. Any word length data is considered valid data; if the post-ratio reference is greater than n011 (max frequency), the commanded reference will be n011 (See Fig. 2).
Detailed Description of Functionality:
Ratio Function
When n004 = 10, the frequency reference is given by the Memobus broadcast register 0004H multiplied by the ratio of n045 / n046.
Frequency reference
=
Memobus register 0004H
× n045 n046
The calculation is updated each time a write to the register is made.
Fig. 2 – Block Diagram of Winder Ratio Frequency Reference n040
Ratio Numerator n011
Max Frequency
Memobus broadcast register 0004H x ÷
Upper/lower limit (n033/n034)
Jump frequencies (n083 - n085)
Minimum frequency (n016)
Frequency reference n041
Ratio Denominator
New write to 0004H
Date: 07/01/04, Rev: 04-07 Page 3 of 4 TM.V7SW.032L
If the Communication/control circuit multi-function input (n050 ~ n056 = 18) is closed and n004 = 10, the winder ratio reference will become active. For other n004 settings the normal Memobus reference will be active.
Memobus Function Code 06H
Support for function code 06H (single register write) is added. The format for the message is shown below.
(Example)
Query Message
Slave address
Function code
01H
06H
Register Upper 00H
Address Lower 01H
Setting
Data
CRC-16
Upper 00H
Lower 03H
Upper 98H
Lower 0BH
Response Message (Normal)
Slave address
Function code
01H
06H
Register Upper 00H
Address Lower 01H
Setting
Data
Upper 00H
Lower 03H
CRC-16
Upper 98H
Lower 0BH
Response Message (Error)
Slave address 01H
80H + Function Code 86H
Error code 21H
Upper 82H
CRC-16
Lower 78H
Date: 07/01/04, Rev: 04-07 Page 4 of 4 TM.V7SW.032L