Chapter 6

Symbologies

The scanner supports the following symbologies (bar code types). Options for each symbology are included in this chapter.

• UPC-A

• UPC-E

• EAN-13

• EAN-8

• GS1 DataBar Omnidirectional /

Stacked Omnidirectional

• GS1 DataBar Expanded /

Expanded Stacked

• GS1 DataBar Limited

• Code 39

• Code 32 Italian

Pharmacode

• Code 128

• Interleaved 2 of 5

• Codabar

• Code 93

• MSI

Factory Defaults— for the standard RS-232 interface are indicated in bold text throughout this

section. Reference Appendix D, Factory Default Settings

for default exceptions for your interface.

UPC-A

Disable/Enable UPC-A

When disabled, the scanner will not read UPC-A bar codes.

START / END

PROGRAMMING bar codes

Disable UPC-A

Enable UPC-A

DEFAULT

85

Product Reference Guide

Symbologies

UPC-A — continued

Check Digit Transmission

Enable this option to transmit the check digit along with UPC-A bar code data.

START / END

PROGRAMMING bar codes

Don’t Send Check Digit

³ 0 0 0 0

Send Check Digit

DEFAULT

Number System Transmission

This feature enables/disables transmission of UPC-A System Number.

START / END

PROGRAMMING bar codes

Disable Number System Transmission

Enable Number System Transmission

DEFAULT

86

Magellan TM 3300HSi

UPC-A

UPC-A — continued

Expand UPC-A to EAN-13

Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.

START / END

PROGRAMMING bar codes

Don’t Expand to EAN-13

DEFAULT

Expand to EAN-13

Product Reference Guide 87

Symbologies

UPC-E

The following options apply to the UPC-E symbology.

Disable/Enable UPC-E

When disabled, the scanner will not read UPC-E bar codes.

START / END

PROGRAMMING bar codes

Disable UPC-E

Enable UPC-E

DEFAULT

Check Digit Transmission

Enable this option to transmit the check digit along with UPC-E bar code data.

START / END

PROGRAMMING bar codes

Don’t Send Check Digit

Send Check Digit

DEFAULT

88

Magellan TM 3300HSi

UPC-E — continued

Number System Digit

The Number System Digit (NSD) which is always a zero (0) in the leading position can be optionally included (or not) with scanned bar code data.

UPC-E

START / END

PROGRAMMING bar codes

Exclude Number System Digit

DEFAULT

Include Number System Digit

³ 0 2 8 0 1

Expand to UPC-E to UPC-A

Enables/disables expansion of UPC-E labels to UPC-A.

Selecting this feature also changes the symbology ID to match those required for UPC-A.

START / END

PROGRAMMING bar codes

Don’t Expand UPC-E to UPC-A

DEFAULT

Expand UPC-E to UPC-A

Product Reference Guide 89

Symbologies

UPC-E — continued

Expand UPC-E to EAN13

Enables/disables expansion of UPC-E labels to EAN-13. Selecting this feature also changes the symbology ID to match those required for EAN-13.

START / END

PROGRAMMING bar codes

Don’t Expand UPC-E to EAN-13

DEFAULT

Expand UPC-E to EAN-13

90

Magellan TM 3300HSi

UPC-E

GTIN

The following options apply to the GTIN label data format.

Expand UPC/EAN to GTIN

When this feature is enabled, the scanner will translate UPC/EAN labels to the 14 digit GTIN format.

START / END

PROGRAMMING bar codes

Don’t Expand to GTIN

DEFAULT

Expand to GTIN

Product Reference Guide 91

Symbologies

EAN-13

The following options apply to the EAN-13 symbology.

Disable/Enable EAN-13

When disabled, the scanner will not read EAN-13 bar codes.

START / END

PROGRAMMING bar codes

Disable EAN-13

Enable EAN-13

DEFAULT

Check Digit Transmission

Enable this option to transmit the check digit along with EAN-13 bar code data.

START / END

PROGRAMMING bar codes

Don’t Send Check Digit

Send Check Digit

DEFAULT

92

Magellan TM 3300HSi

EAN-13

EAN-13 — continued

EAN-13 Flag 1 Character

Enables/disables transmission of an EAN/JAN13 Flag1 character.

START / END

PROGRAMMING bar codes

Don’t Transmit EAN-13 Flag 1 Char

Transmit EAN-13 Flag 1 Char

DEFAULT

ISBN

When enabled, this feature truncates the leading three digits from labels that contain ISBN

(International Standard Book Number) and appends an ISBN check character to the end of the label. These codes are used for books and magazines. Labels with ISBN codes start with "978".

Example:

Bar Code data:

Output:

“9789572222720”

“9572222724”

START / END

PROGRAMMING bar codes

Disable ISBN

DEFAULT

Enable ISBN

Product Reference Guide 93

Symbologies

EAN-8

The following options apply to the EAN-8 symbology.

Disable/Enable EAN-8

When disabled, the scanner will not read EAN-8 bar codes.

START / END

PROGRAMMING bar codes

Disable EAN-8

Enable EAN-8

DEFAULT

Check Digit Transmission

Enable this option to transmit the check Digit along with EAN-8 bar code data.

START / END

PROGRAMMING bar codes

Don’t Send Check Digit

Send Check Digit

DEFAULT

94

Magellan TM 3300HSi

EAN-8

EAN-8 — continued

Expand EAN-8 to EAN-13— Expands EAN-8 data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.

START / END

PROGRAMMING bar codes

Don’t Expand to EAN-13

DEFAULT

Expand to EAN-13

Product Reference Guide 95

Symbologies

EAN Two-Label

Enables/disables the ability of the scanner to decode EAN two-label pairs.

START / END

PROGRAMMING bar codes

Disable EAN Two-Label

Enable EAN Two-Label

EAN Two-Label Combined Transmission

Enables/disables the transmitting of an EAN two label pair as one label.

START / END

PROGRAMMING bar codes

EAN Two-Label Combined Transmission = Disable

DEFAULT

EAN Two-Label Combined Transmission = Enable

96

Magellan TM 3300HSi

Price Weight Check Digit

Price Weight Check Digit

Enables/disables calculation and verification of price/weight check digits.

Applies to all UPC-A labels with a number-system character of

2 and EAN/JAN 13 labels with a

1 digit of 2

NOTE

Here are the available options for this feature:

• Disable

• Enable 4-digit price/wt check-digit calculation

• Enable 5-digit price/wt check-digit calculation

• Enable European 4-digit price-weight check-digit calculation

• Enable European 5-digit price-weight check-digit calculation

START / END

PROGRAMMING bar codes

Price Weight Check Digit = Disable

DEFAULT

Price Weight Check Digit = Enable 4-digit price/wt

Price Weight Check Digit = Enable 5-digit price/wt

Price Weight Check Digit = Enable European 4-digit price/wt

Price Weight Check Digit = Enable European 5-digit price/wt

Product Reference Guide 97

Symbologies

Add-ons

Add-ons (or supplemental characters) are commonly added to the end of UPC/EAN bar codes.

The scanner will read the add-ons if they are enabled and in the field of view. Three add-on types are supported: 2-digit, 5-digit and Code 128 add-ons. Supported options are:

None— This option directs the scanner to ignore add-on portion of a UPC/EAN bar code but still read the main portion of the bar code.

2 Digits— The scanner will optionally read 2-digit add-ons with the UPC/EAN label.

5 Digits— The scanner will optionally read 5-digit add-ons with the UPC/EAN label.

Code 128 Add-on— The scanner will optionally read Code 128 add-ons with the UPC/EAN label.

Contact Customer Support for advanced programming of optional and conditional add-ons.

NOTE

98

Magellan TM 3300HSi

Add-ons — continued

START / END

PROGRAMMING bar codes

Disable Optional 2-Digit Add-ons

DEFAULT

Enable Optional 2-Digit Add-ons

Disable Optional 5-Digit Add-ons

DEFAULT

Enable Optional 5-Digit Add-ons

³ 0 1 1 0 1

Disable Optional Code 128 Add-ons

DEFAULT

Enable Optional Code 128 Add-ons

Add-ons

Product Reference Guide 99

Symbologies

GS1 DataBar Omnidirectional / Stacked Omnidirectional

The following options apply to the GS1 DataBar Omnidirectional symbology.

Disable/Enable GS1 DataBar Omnidirectional

When this feature is disabled, the scanner will not read GS1 DataBar Omnidirectional bar codes.

START / END

PROGRAMMING bar codes

Disable GS1 DataBar Omnidirectional

DEFAULT

Enable GS1 DataBar Omnidirectional

UCC/EAN 128 Emulation

When enabled, GS1 DataBar Omnidirectional bar codes will be translated to the UCC/EAN

128 label data format.

START / END

PROGRAMMING bar codes

Disable UCC/EAN 128 Emulation

DEFAULT

Enable UCC/EAN 128 Emulation

100

Magellan TM 3300HSi

GS1 DataBar Expanded / Expanded Stacked

GS1 DataBar Expanded / Expanded Stacked

The following options apply to the GS1 DataBar Expanded symbology.

Disable/Enable GS1 DataBar Expanded

When this feature is disabled, the scanner will not read GS1 DataBar Expanded bar codes.

START / END

PROGRAMMING bar codes

Disable GS1 DataBar Expanded

DEFAULT

Enable GS1 DataBar Expanded

GS1-128 Emulation

When enabled, GS1 DataBar Expanded bar codes will be translated to the GS1-128 label data format.

START / END

PROGRAMMING bar codes

Disable GS1-128 Emulation

DEFAULT

Enable GS1-128 Emulation

Product Reference Guide 101

Symbologies

GS1 DataBar Expanded / Expanded Stacked — continued

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2 values.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

GS1 DataBar Expanded Length 1, Length 2 Programming Instructions

See

Length 1, Length 2 Programming Instructions on page 154 for

detailed instructions on setting this feature.

For GS1 DataBar Expanded bar codes, only the data characters are included in the length calculations.

NOTE

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 01

Set Length 2

102

Magellan TM 3300HSi

GS1 DataBar Expanded / Expanded Stacked

GS1 DataBar Expanded / Expanded Stacked — continued

Coupon Read Control

This feature controls coupon reading.

START / END

PROGRAMMING bar codes

Disable coupon filtering

Enable UPCA coupon decoding

Disable GS1 DataBar coupon decoding

DEFAULT

Enable GS1 DataBar coupon decoding

Disable UPCA coupon decoding

Product Reference Guide 103

Symbologies

GS1 DataBar Limited

The following options apply to the GS1 DataBar Limited symbology.

Disable/Enable GS1 DataBar Limited

When this feature is disabled, the scanner will not read GS1 DataBar Limited bar codes.

START / END

Enable GS1 DataBar Limited

PROGRAMMING bar codes

Disable GS1 DataBar Limited

DEFAULT

GS1-128 Emulation

When enabled, GS1 DataBar Limited bar codes will be translated to the GS1-128 label data format.

START / END

PROGRAMMING bar codes

Disable GS1-128 Emulation

DEFAULT

Enable GS1-128 Emulation

104

Magellan TM 3300HSi

Code 39

Code 39

The following options apply to the Code 39 symbology.

Disable/Enable Code 39

When this feature is disabled, the scanner will not read Code 39 bar codes.

START / END

PROGRAMMING bar codes

Disable Code 39

Enable Code 39

DEFAULT

Check Character Calculation

When enabled, the scanner will calculate the check character of the labels. Turn this option on only when a checksum is present in the Code 39 labels.

START / END

PROGRAMMING bar codes

Disable Check Char Calculation

DEFAULT

Enable Check Char Calculation

Product Reference Guide 105

Symbologies

Check Character Transmit

Enable this option to transmit the check character with scanned bar code data.

START / END

PROGRAMMING bar codes

Disable Check Char Transmission

Enable Check Char Transmission

DEFAULT

Start/Stop Characters

Enables/disables transmission of Code39 start and stop characters.

START / END

PROGRAMMING bar codes

Don’t Transmit Start/Stop Characters

DEFAULT

Transmit Start/Stop Characters

106

Magellan TM 3300HSi

Code 39 Full ASCII

Enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters .

Code 39

START / END

PROGRAMMING bar codes

Disable Code 39 Full ASCII

DEFAULT

Enable Code 39 Full ASCII

Product Reference Guide 107

Symbologies

Code 39 — continued

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2 values.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

Code 39 Length 1, Length 2 Programming Instructions

See

Length 1, Length 2 Programming Instructions on page 154 for

detailed instructions on setting this feature.

For Code 39 bar codes, all check, data and full

ASCII shift characters are included in the length calculations. Start/Stop characters are not included.

NOTE

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 02

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 50

108

Magellan TM 3300HSi

Code 32 Italian Pharmacode

Code 32 Italian Pharmacode

The following options apply to the Code 32 Italian Pharmacode symbology.

Disable/Enable Code 32 Italian Pharmacode

When this feature is disabled, the scanner will not read Code 32 Italian Pharmacode bar codes.

START / END

PROGRAMMING bar codes

Disable Code 32 Italian Pharmacode

DEFAULT

Enable Code 32 Italian Pharmacode

Start/Stop Characters

Enables or disables transmission of Code 32 Italian Pharmacode start/stop characters.

START / END

PROGRAMMING bar codes

Don’t Transmit Start/Stop Characters

DEFAULT

Transmit Start/Stop Characters

³ 0 0 6 0 1

Product Reference Guide 109

Symbologies

Code 32 Italian Pharmacode — continued

Check Character Transmit

Enable this option to transmit the check character with scanned bar code data.

START / END

PROGRAMMING bar codes

Disable Check Char Transmission

Enable Check Char Transmission

DEFAULT

110

Magellan TM 3300HSi

Code 128

The following options apply to the Code 128 symbology.

Disable/Enable Code 128

When this feature is disabled, the scanner will not read Code 128 bar codes.

START / END

PROGRAMMING bar codes

Disable Code 128

Enable Code 128

DEFAULT

Code 128

Disable/Enable EAN 128

When this feature is disabled, the scanner will not read EAN 128 bar codes.

START / END

PROGRAMMING bar codes

Disable EAN 128

Enable EAN 128

DEFAULT

Product Reference Guide 111

Symbologies

Code 128 — continued

Transmit Function Characters

Enables/disables transmission of Code 128 function characters 1, 2, 3, and 4.

Function codes are transmitted as follows:

• FNC1 = 80 hex

• FNC2 = 81 hex

• FNC3 = 82 hex

• FNC4 = 83 hex

START / END

PROGRAMMING bar codes

Don’t Transmit Function Characters

DEFAULT

Transmit Function Characters

112

Magellan TM 3300HSi

Code 128

Code 128 — continued

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2 values.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

Code 128 Length 1, Length 2 Programming Instructions

See

Length 1, Length 2 Programming Instructions on page 154 for

detailed instructions on setting this feature.

For Code 128 bar codes, only the data characters are included in the length calculations.

NOTE

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 01

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 80

Product Reference Guide 113

Symbologies

Code 128 Conversion to Code 39

Enables/disables expansion of Code 128 labels to Code 39.

START / END

PROGRAMMING bar codes

Disable

DEFAULT

Enable

Interleaved 2 of 5

The following options apply to the Interleaved 2 of 5 (I 2 of 5) symbology.

Disable/Enable Interleaved 2 of 5

When this feature is disabled, the scanner will not read Interleaved 2 of 5 bar codes.

START / END

PROGRAMMING bar codes

Disable Interleaved 2 of 5

DEFAULT

Enable Interleaved 2 of 5

114

Magellan TM 3300HSi

Interleaved 2 of 5

Check Digit Calculation

When enabled, the scanner will calculate the check digit of the labels.

START / END

PROGRAMMING bar codes

Disable Check Digit Calculation

DEFAULT

Enable Check Digit Calculation

Check Digit Transmit

Enable this option to transmit the check digit with scanned bar code data.

START / END

PROGRAMMING bar codes

Disable Check Digit Calculation

DEFAULT

Enable Check Digit Calculation

Product Reference Guide 115

Symbologies

Interleaved 2 of 5 — continued

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2 values.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

Interleaved 2 of 5 Length 1, Length 2 Programming Instructions

See

Length 1, Length 2 Programming Instructions on page 154 for

detailed instructions on setting this feature.

For Interleaved 2 of 5 bar codes, lengths must be an even number. Additionally, all check and data characters are included in the length calculations.

NOTE

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 06

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 50

116

Magellan TM 3300HSi

Codabar

The following options apply to the Codabar symbology.

Disable/Enable Codabar

When this feature is disabled, the scanner will not read Codabar bar codes.

START / END

PROGRAMMING bar codes

Disable Codabar

DEFAULT

Enable Codabar

Check Character Verification

When enabled, the scanner will verify the check character of the labels.

START / END

PROGRAMMING bar codes

Disable Check Char Verification

DEFAULT

Enable Check Char Verification

Codabar

Product Reference Guide 117

Symbologies

Check Character Transmit

Enable this option to transmit the check character with scanned bar code data.

START / END

PROGRAMMING bar codes

Disable Check Char Transmission

Enable Check Char Transmission

DEFAULT

118

Magellan TM 3300HSi

Codabar

Codabar — continued

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2 values.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

Codabar Length 1, Length 2 Programming Instructions

See

Length 1, Length 2 Programming Instructions on page 154 for

detailed instructions on setting this feature.

For Codabar bar codes, all start, stop, check and data characters are included in the length calculations.

NOTE

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 03

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 50

Product Reference Guide 119

Symbologies

Codabar — continued

Start/Stop Character Type

Codabar has four pairs of Start/Stop patterns. Select one pair to match your application.

START / END

PROGRAMMING bar codes

Start/Stop Type: ABCD/TN*E

Start/Stop Type: ABCD/ABCD

Start/Stop Type: abcd/tn*e

Start/Stop Type: abcd/abcd

DEFAULT

Start/Stop Character Transmission

The transmission of start and end characters of Codabar is selected below.

START / END

PROGRAMMING bar codes

Disable Start/Stop Char Transmission

Enable Start/Stop Char Transmission

DEFAULT

120

Magellan TM 3300HSi

Start/Stop Character Match

This feature enables/disables the requirement that start and stop characters match .

START / END

PROGRAMMING bar codes

Disable Start/Stop Char Match

DEFAULT

Enable Start/Stop Char Match

Code 93

The following options apply to the Code 93 symbology.

Disable/Enable Code 93

When this feature is disabled, the scanner will not read Code 93 bar codes.

START / END

PROGRAMMING bar codes

Disable Code 93

DEFAULT

Enable Code 93

Code 93

Product Reference Guide 121

Symbologies

Code 93 — continued

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2 values.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

Code 93 Length 1, Length 2 Programming Instructions

See

Length 1, Length 2 Programming Instructions on page 154 for

detailed instructions on setting this feature.

For Code 93 bar codes, only the data characters are included in the length calculations.

NOTE

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 01

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 50

122

Magellan TM 3300HSi

MSI

The following options apply to the MSI symbology.

Disable/Enable MSI

When this feature is disabled, the scanner will not read MSI bar codes.

START / END

PROGRAMMING bar codes

Disable Code 93

DEFAULT

Enable Code 93

MSI Check Character Transmit

Enable this option to transmit the check character with scanned bar code data.

Applies when

MSI Check Character Calculation is enabled.

START / END

PROGRAMMING bar codes

Disable Check Char Transmission

Enable Check Char Transmission

DEFAULT

MSI

Product Reference Guide 123

Symbologies

MSI — continued

MSI Check Character Calculation

Enables/disables calculation and verification of optional MSI check characters. When disabled, any check characters in an MSI label are treated as data characters.

START / END

PROGRAMMING bar codes

Disable Check Character Calculation

Enable Check Character Calculation

DEFAULT

MSI Number of Check Characters

Specifies number of MSI check characters to be calculated and verified.

START / END

PROGRAMMING bar codes

One Check Character

DEFAULT

Two Check Characters

124

Magellan TM 3300HSi

MSI

MSI — continued

MSI Length Control

Specifies either variable-length decoding or fixed-length decoding for MSI.

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2 values.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

MSI Length 1, Length 2 Programming Instructions

1. See Length 1, Length 2 Programming Instructions on page 154 for detailed instructions on setting this feature .

For MSI bar codes, length includes the barcode's check and data characters.

NOTE

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 04

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 10

Product Reference Guide 125

Symbologies

NOTES

126

Magellan TM 3300HSi

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement

Table of contents