2D Symbologies. Datalogic Magellan 3300HSi


Add to my manuals
208 Pages

advertisement

2D Symbologies. Datalogic Magellan 3300HSi | Manualzz

2D Symbologies

The features in this section are available ONLY for models with 2D features activated.

NOTE

2D Symbologies

The scanner supports the 2D symbologies (bar code types) listed below. Available options for each 2D symbology are included in this chapter.

• PDF 417

• Micro PDF 417

• Datamatrix

• QR Code

• Maxicode

• Aztec

• Composite Labels

Factory Defaults— for the standard RS-232 interface are indicated in bold text throughout.

Product Reference Guide

127

2D Symbologies

PDF 417

Disable/Enable PDF 417

When disabled, the scanner will not read PDF 417 bar codes.

START / END

PROGRAMMING bar codes

Disable PDF 417

Enable PDF 417

DEFAULT

Allow Zero Length PDF 417 Reading

This enables/disables the scanner’s ability to read PDF417 bar codes containing a zero length codeword.

START / END

PROGRAMMING bar codes

Disable Zero Length PDF 417 Reading

DEFAULT

Enable Zero Length PDF 417 Reading

128

Magellan TM 3300HSi

2D Symbologies

PDF 417 — continued

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length.

Configuring Fixed Length Decoding:

1. Scan the START bar code.

2. Scan the Fixed Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the first fixed length by following the Length 1, Length 2 Programming

Instructions below.

5. Set Length 2 to the second fixed length (or to ‘0000’ if there is only one fixed length) by following the

PDF 417 Length 1, Length 2 Programming Instructions

below.

Configuring Variable Length Decoding:

1. Scan the START bar code.

2. Scan the Variable Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the minimum length by following the PDF 417 Length 1, Length 2 Programming Instructions below.

5. Set Length 2 to the maximum length by following the PDF 417 Length 1, Length 2 Programming Instructions below.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

Product Reference Guide 129

2D Symbologies

PDF 417 — continued

PDF 417 Length 1, Length 2 Programming Instructions

1. Scan the START bar code.

2. Scan either the Set Length 1 or Set Length 2 bar code.

3. Turn to Appendix C, Alpha-Numeric Pad

and scan the four digits (zero-padded) representing the length.

For PDF 417 bar codes, only the data characters are included in the length calculations.

Any value set higher than 2710 will be considered to be 2710.

NOTE

Scan the END bar code.

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 0001

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 2710

130

Magellan TM 3300HSi

Micro PDF 417

Disable/Enable Micro PDF 417

When disabled, the scanner will not read Micro PDF 417 bar codes.

START / END

PROGRAMMING bar codes

Disable Micro PDF 417

DEFAULT

2D Symbologies

Enable Micro PDF 417

Product Reference Guide 131

2D Symbologies

Micro PDF 417 — continued

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length.

Configuring Fixed Length Decoding:

1. Scan the START bar code.

2. Scan the Fixed Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the first fixed length by following the Length 1, Length 2 Programming

Instructions below.

5. Set Length 2 to the second fixed length (or to ‘0000’ if there is only one fixed length) by following the

Micro PDF 417 Length 1, Length 2 Programming Instructions below.

Configuring Variable Length Decoding:

1. Scan the START bar code.

2. Scan the Variable Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the minimum length by following the Micro PDF 417 Length 1, Length 2

Programming Instructions below.

5. Set Length 2 to the maximum length by following the Micro PDF 417 Length 1, Length 2

Programming Instructions below.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

132

Magellan TM 3300HSi

2D Symbologies

Micro PDF 417 — continued

Micro PDF 417 Length 1, Length 2 Programming Instructions

1. Scan the START bar code.

2. Scan either the Set Length 1 or Set Length 2 bar code.

3. Turn to Appendix C, Alpha-Numeric Pad

and scan the four digits (zero-padded) representing the length.

For Micro PDF 417 bar codes, only the data characters are included in the length calculations.

Any value set higher than 366 will be considered to be 366.

NOTE

Scan the END bar code.

START / END

PROGRAMMING bar codes

Set Length 1

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 0366

Product Reference Guide 133

2D Symbologies

Datamatrix

Disable/Enable Datamatrix

When disabled, the scanner will not read Datamatrix bar codes.

START / END

PROGRAMMING bar codes

Disable Datamatrix

Enable Datamatrix

DEFAULT

134

Magellan TM 3300HSi

2D Symbologies

Datamatrix — continued

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length.

Configuring Fixed Length Decoding:

1. Scan the START bar code.

2. Scan the Fixed Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the first fixed length by following the Length 1, Length 2 Programming

Instructions below.

5. Set Length 2 to the second fixed length (or to ‘0000’ if there is only one fixed length) by following the

Datamatrix Length 1, Length 2 Programming Instructions below.

Configuring Variable Length Decoding:

1. Scan the START bar code.

2. Scan the Variable Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the minimum length by following the Datamatrix Length 1, Length 2 Programming Instructions below.

5. Set Length 2 to the maximum length by following the Datamatrix Length 1, Length 2 Programming Instructions below.

START / END

Fixed Length Decoding

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Product Reference Guide 135

2D Symbologies

Datamatrix — continued

Datamatrix Length 1, Length 2 Programming Instructions

1. Scan the START bar code.

2. Scan either the Set Length 1 or Set Length 2 bar code.

3. Turn to Appendix C, Alpha-Numeric Pad

and scan the four digits (zero-padded) representing the length.

For Datamatrix bar codes, only the data characters are included in the length calculations.

Any value set higher than 800 will be considered to be 800.

NOTE

Scan the END bar code.

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 0001

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 0800

136

Magellan TM 3300HSi

QR Code

Disable/Enable QR Code

When disabled, the scanner will not read QR Code labels.

START / END

PROGRAMMING bar codes

Disable QR Code

DEFAULT

Enable QR Code

2D Symbologies

Product Reference Guide 137

2D Symbologies

QR Code — continued

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length.

Configuring Fixed Length Decoding:

1. Scan the START bar code.

2. Scan the Fixed Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the first fixed length by following the Length 1, Length 2 Programming

Instructions below.

5. Set Length 2 to the second fixed length (or to ‘0000’ if there is only one fixed length) by following the

QR Code Length 1, Length 2 Programming Instructions

below.

Configuring Variable Length Decoding:

1. Scan the START bar code.

2. Scan the Variable Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the minimum length by following the QR Code Length 1, Length 2 Programming Instructions below.

5. Set Length 2 to the maximum length by following the QR Code Length 1, Length 2 Programming Instructions below.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

138

Magellan TM 3300HSi

2D Symbologies

QR Code — continued

QR Code Length 1, Length 2 Programming Instructions

1. Scan the START bar code.

2. Scan either the Set Length 1 or Set Length 2 bar code.

3. Turn to Appendix C, Alpha-Numeric Pad

and scan the four digits (zero-padded) representing the length.

For 2d Code labels, only the data characters are included in the length calculations.

Any value set higher than 2710 will be considered to be 2710.

NOTE

Scan the END bar code.

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 0001

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 2710

Product Reference Guide 139

2D Symbologies

Maxicode

Disable/Enable Maxicode

When disabled, the scanner will not read Maxicode labels.

START / END

PROGRAMMING bar codes

Disable Maxicode

DEFAULT

Enable Maxicode

140

Magellan TM 3300HSi

2D Symbologies

Maxicode — continued

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length.

Configuring Fixed Length Decoding:

1. Scan the START bar code.

2. Scan the Fixed Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the first fixed length by following the Length 1, Length 2 Programming

Instructions below.

5. Set Length 2 to the second fixed length (or to ‘0000’ if there is only one fixed length) by following the

Maxicode Length 1, Length 2 Programming Instructions below.

Configuring Variable Length Decoding:

1. Scan the START bar code.

2. Scan the Variable Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the minimum length by following the Maxicode Length 1, Length 2 Programming Instructions below.

5. Set Length 2 to the maximum length by following the Maxicode Length 1, Length 2 Programming Instructions below.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

Product Reference Guide 141

2D Symbologies

Maxicode — continued

Maxicode Length 1, Length 2 Programming Instructions

1. Scan the START bar code.

2. Scan either the Set Length 1 or Set Length 2 bar code.

3. Turn to Appendix C, Alpha-Numeric Pad

and scan the four digits (zero-padded) representing the length.

For Maxicode labels, only the data characters are included in the length calculations.

Any value set higher than 138 will be considered to be 138.

NOTE

Scan the END bar code.

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 0001

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 0138

142

Magellan TM 3300HSi

Aztec

Disable/Enable Aztec

When disabled, the scanner will not read Aztec labels.

START / END

PROGRAMMING bar codes

Disable Aztec

DEFAULT

Enable Aztec

2D Symbologies

Product Reference Guide 143

2D Symbologies

Aztec — continued

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length.

Configuring Fixed Length Decoding:

1. Scan the START bar code.

2. Scan the Fixed Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the first fixed length by following the Length 1, Length 2 Programming

Instructions below.

5. Set Length 2 to the second fixed length (or to ‘0000’ if there is only one fixed length) by following the

Aztec Length 1, Length 2 Programming Instructions below.

Configuring Variable Length Decoding:

1. Scan the START bar code.

2. Scan the Variable Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the minimum length by following the Aztec Length 1, Length 2 Programming Instructions

below.

5. Set Length 2 to the maximum length by following the Aztec Length 1, Length 2 Programming Instructions

below.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

144

Magellan TM 3300HSi

2D Symbologies

Aztec — continued

Aztec Length 1, Length 2 Programming Instructions

1. Scan the START bar code.

2. Scan either the Set Length 1 or Set Length 2 bar code.

3. Turn to Appendix C, Alpha-Numeric Pad

and scan the four digits (zero-padded) representing the length.

For Aztec labels, only the data characters are included in the length calculations.

Any value set higher than 3700 will be considered to be 2710.

NOTE

Scan the END bar code.

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 0001

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 2710

Product Reference Guide 145

2D Symbologies

Composite Labels

Disable/Enable GS1 DataBar Omnidirectional 2D Component

When enabled, if a GS1 DataBar Omnidirectional label is decoded which has the 2D linkage flag set, the 2D component must also be decoded or the base label will be discarded.

When disabled, only the GS1 DataBar Omnidirectional base label will be decoded and transmitted regardless of the state of the linkage flag.

START / END

PROGRAMMING bar codes

Disable GS1 DataBar Omnidirectional 2D Component

DEFAULT

Enable GS1 DataBar Omnidirectional 2D Component

Disable/Enable GS1 DataBar Expanded 2D Component

When enabled, if a GS1 DataBar Expanded label is decoded which has the 2D linkage flag set, the 2D component must also be decoded or the base label will be discarded.

When disabled, only the GS1 DataBar Expanded base label will be decoded and transmitted regardless of the state of the linkage flag.

START / END

PROGRAMMING bar codes

Disable GS1 DataBar Expanded 2D Component

DEFAULT

Enable GS1 DataBar Expanded 2D Component

146

Magellan TM 3300HSi

2D Symbologies

Disable/Enable GS1 DataBar Limited 2D Component

When enabled, if a GS1 DataBar Limited label is decoded which has the 2D linkage flag set, the

2D component must also be decoded or the base label will be discarded.

When disabled, only the GS1 DataBar Limited base label will be decoded and transmitted regardless of the state of the linkage flag.

START / END

PROGRAMMING bar codes

Disable GS1 DataBar Limited 2D Component

DEFAULT

Enable GS1 DataBar Limited 2D Component

Product Reference Guide 147

2D Symbologies

NOTES

148

Magellan TM 3300HSi

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement

Table of contents