Communication protocol: RS232 Communication Protocol

Baud rate: 9600 Data bit: 8 Stop bit: 1 Parity bit: none

Command

Types

Command

Codes

/*Type;

Functions

Inquire the models information.

/%Lock;

/%Unlock;

Lock the keyboard of the control panel on the

Matrix.

Unlock the keyboard of the control panel on the

Matrix.

System

Command

/^Version;

/:MessageOff;

/:MessageOn;

Demo.

Undo.

[x]All.

Inquire the version of firmware

Turn off the feedback command from the com port. It will only show the “SWITCH OK”.

Turn on the feedback command from the com port.

Switch to the “demo” mode, 1->1, 2->2, 3->3 … and so on .The switching interval is 2 seconds.

To cancel the previous operation.

Transfer signals from the input channel [x] to all output channels

Operation

Command

(PTN2.0

Command

System)

All#.

All$.

[x]#.

[x]$.

[x1] V[x2].

[x1] B[x2].

Status.

Save[X].

Recall[Y].

Clear[Y].

PWON.

PWOFF.

Transfer all input signals to the corresponding output channels respectively.

Switch off all the output channels.

Transfer signals from the input channel [xq] to the output channel [x].

Switch off the output channel [x].

Transfer the AV signal from the input channel

[x1] to the output channel [x2].

Transfer the AV and IR signal from the input channel [x1] to the output channel [x2].

Inquire the input channel to the output channels one by one.

Save the present operation to the preset command [X], ranges from 0 to 9.

Recall the preset command [Y].

Clear the preset command [Y].

Work in normal mode.

Enter into standby mode.

PTN Electronics Limited 10 www.PTN-electronics.com

HDBaseT Matrix Switchers 4x4

/%[Y]/[X]:[Z].

HDCP management command. [Y] is for input

(value: I) or output (value: O). [X] is the number of one port, if the value of X is ALL, it means all ports. [Z] is for working status (Value: 1 or 0).

 Y=I & Z=1, means the input port is compliant with HDCP.

 Y=O & Z=1, means output with HDCP.

 Y=I & Z=0, means the input port is not compliant with HDCP.

 Y=O & Z=0, means output without HDCP.

%0801.

%0800.

[x1] R[x2].

/+[Y]/[X]:******.

%9971.

%9972.

%9973.

%9974.

%9975.

%9976.

EDIDG[x].

EDIDMInit.

Automatically HDCP management.

Manually HDCP management.

Transfer the IR signal from the input channel

[x1] to the output channel [x2].

Set communication between PC and

TPHD402R.

 [Y] is for port number

 [X] is for bound rate (Value ranges from 1 to 7, 1 is for 2400, 2 for 4800, 3 for 9600, 4 for 19200, 5 for 38400, 6 for 57600 and 7 for 115200)

 ***** is for data (max 48 Byte, the symbol

“.” Is unavailable)

 Note: when the value of Y is 5, it means that to send data to all 4 ports synchronously.

Check the connection status of the inputs.

Check the connection status of the outputs.

Check the HDCP status of the inputs.

Check the HDCP status of the outputs.

Check the switching status.

Check the output resolution.

Get EDID data from the output and display the output port number of X.

Recover the factory default EDID data.