Run the interconnection cable (NS003105/NS003106) to the radar processor. North Star 10 kW, 25 kW
Add to my manuals
53 Pages
advertisement
You can connect the radar processor to either the Northstar 6100i OR to the Northstar 8000i, but not to both simultaneously.
25 kW radar processor interface connectors
Connector name Connector function Connects to...
Network
Power (+Ve and -Ve)
NMEA / Comms
Scanner
Chassis Earth
Ethernet communications for the 8000i
Power input
8000i network, using the 8000i network cable (NS00481X)
Ship's power 24 V DC ONLY (using the power cable)
Data communications (for the
6000i and 6100i systems only)
Remote power control, relay and ignition (for the 6000i,
6100i, and 8000i)
6000i or 6100i display unit, using radar communications cable
(NS003107/NS003108)
6000i, 6100i, or 8000i remote power signals, relay or ignition; cable not supplied
NMEA communications for compass (for the 8000i only).
Scanner communications
Grounding point
8000i NMEA compliant compass; cable not supplied
Scanner, using the interconnection cable (NS003105 or NS003106)
Vessel's Ground using ground wire
12.4 Run the interconnection cable (NS003105/NS003106) to the radar processor
Run the interconnection cable (NS003105/NS003106) from the scanner unit to the radar processor.
Push the round connector (A) of the interconnection cable into the scanner connection on the radar processor and tighten the locking nut.
Northstar 25 kW Radar Installation Manual 27
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 17 How to find the optimum height for the scanner
- 18 How to find the maximum detection range
- 19 How to reduce false echoes and shadow zones
- 19 Install an open array scanner on a trestle
- 20 25 kW radar dimensions
- 21 Install the 25 kW scanner unit
- 21 When to install the open array
- 22 Install the radar processor
- 23 Wiring guidelines
- 23 Connect the interconnection cable (NS003105/NS003106) to the 25 kW scanner
- 26 25 kW radar processor connectors
- 27 Run the interconnection cable (NS003105/NS003106) to the radar processor
- 28 Earth the 25 kW scanner
- 29 Install the 25 kW open array
- 30 Connect the 25 kW radar processor to a 6000i or 6100i display
- 31 Connect the radar communications cable (NS003107) to the junction box
- 33 Configure the remote power control for a 6000i or 6100i (common power source)
- 34 Configure the remote power control for a 6000i or 6100i (different power sources)
- 35 Connect the 25 kW radar processor to an 8000i display
- 36 Configure the remote power control for an 8000i
- 36 Connect an 8000i network cable (NS00481X)
- 36 Connect the optional NMEA compass for an 8000i
- 36 Configure the optional NMEA compass
- 37 Connect the power cable
- 37 Connect the ground wire
- 38 Radar system checklist
- 39 Turn the radar on and off
- 39 Before you turn on the radar for the first time
- 39 Turn the radar on
- 39 Turn the radar off
- 40 Configure the navigator communications
- 40 Heading sensor requirements
- 40 Disable the heading sensor input
- 41 Calibrating the radar
- 41 Prepare for calibration
- 41 Tune the radar
- 41 Set the STC Curve
- 42 Set the trigger delay
- 42 Set the heading calibration (heading sensor installed)
- 43 Set the heading calibration (heading sensor not installed)
- 43 Adjust the appearance settings
- 44 Restore all the factory settings
- 44 Restore the factory appearance settings
- 45 General maintenance
- 45 Scanner maintenance
- 45 Other maintenance items
- 46 Technical support, service and repairs
- 46 Radar is not operating correctly
- 47 If the scanner fails to turn
- 47 How to reduce noise and interference
- 48 Make sure the power is present and correctly wired
- 48 Confirm the equipment installed
- 48 Are Range Rings displayed?