Connect the radar communications cable (NS003107) to the junction box. North Star 10 kW, 25 kW
Add to my manuals
53 Pages
advertisement
B
C
F
G
I
To NMEA Device 1
To NMEA Device 2
Circuit breaker/fuse box
Optional radar communications extension cable (NS003108)
NTSC Video Input
L Power
M NMEA
N Ethernet
0 AUX
12.7.1 Connect the radar communications cable (NS003107) to the junction box
The free ends of the radar communications cable (NS003107) must be terminated in a junction box
(see the figure in the previous section). The junction box is not supplied.
The communications cable has a 0.41" (10.5 mm) diameter. The junction box must be waterproof and large enough to contain a 20 way strip connector.
All cable entry points should use suitable grommets or glands to ensure that waterproofing is maintained.
The table shows the wiring and pin details of the radar communications cable. The naming convention for the bi-colored wires is primary color/stripe; for example, White/Orange refers to a white colored wire with an orange stripe.
If the radar processor is connected through the 12-pin NMEA/Comms connector on the radar communications cable (NS003107), then all of the NMEA 2 free end signals and grounds must be NO CONNECT in the junction box.
If a SmartCraft device is connected through the 8 pin SmartCraft connector on the radar communications cable
(NS003107), then all the RS-232 free end signals and grounds should be NO CONNECT in the junction box.
NMEA devices must be connected to an unused NMEA port on the connector strip.
The remote power signal configuration is explained in "Configure the remote power control for a
6000i or 6100i (common power source)" and "Configure the remote power control for a 6000i or 6100i
(different power sources)".
Wire function
NMEA 1 IN A
NMEA 1 IN B
NMEA 1 IN GROUND
NMEA 1 OUT A
NMEA 1 OUT B
Free end
Brown
Blue
White/Blue
Violet
Gray
Connector 1
6000i/6100i NMEA
4
12
7
Pin
3
1
Color
Brown
Blue
White/Blue
Violet
Gray
Connector 2
NMEA/Comms
Pin Color
Connector 3
Smartcraft
Pin Color
Northstar 25 kW Radar Installation Manual 31
NMEA 1 OUT GROUND
NMEA 2 IN A
NMEA 2 IN B
NMEA 2 IN GROUND
NMEA 2 OUT A
NMEA 2 OUT B
Blue/White
White/Brown
Brown/White
White
Yellow
Orange
8
6*
2*
5*
15*
11*
Blue/White
White/Brown
Brown/White
White
Yellow
Orange
2
7
8
1 Green
Red
Orange
Blue
NMEA 2 OUT GROUND
RS-232 GROUND
RS-232 RX
RS-232 TX
REMOTE SAVE
Black 10 Black
Tan
Green
Red
17*
16*
18*
Tan
Green
Red
Orange/White 13 Orange/White
Pink 14
12 Yellow
6000i or 6100i REMOTE
POWER OUT
SHIELD
RADAR REMOTE POWER
IN
White/Orange
* See cautions on previous page.
10 Brown
1 White
3 Green
8 Red
The end view of the three connectors is shown:
Connector 1 - 6100i NMEA pin assignments
Connector 2 - Radar NMEA/Communications pin assignments
32 Northstar 25 kW Radar Installation Manual
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 17 How to find the optimum height for the scanner
- 18 How to find the maximum detection range
- 19 How to reduce false echoes and shadow zones
- 19 Install an open array scanner on a trestle
- 20 25 kW radar dimensions
- 21 Install the 25 kW scanner unit
- 21 When to install the open array
- 22 Install the radar processor
- 23 Wiring guidelines
- 23 Connect the interconnection cable (NS003105/NS003106) to the 25 kW scanner
- 26 25 kW radar processor connectors
- 27 Run the interconnection cable (NS003105/NS003106) to the radar processor
- 28 Earth the 25 kW scanner
- 29 Install the 25 kW open array
- 30 Connect the 25 kW radar processor to a 6000i or 6100i display
- 31 Connect the radar communications cable (NS003107) to the junction box
- 33 Configure the remote power control for a 6000i or 6100i (common power source)
- 34 Configure the remote power control for a 6000i or 6100i (different power sources)
- 35 Connect the 25 kW radar processor to an 8000i display
- 36 Configure the remote power control for an 8000i
- 36 Connect an 8000i network cable (NS00481X)
- 36 Connect the optional NMEA compass for an 8000i
- 36 Configure the optional NMEA compass
- 37 Connect the power cable
- 37 Connect the ground wire
- 38 Radar system checklist
- 39 Turn the radar on and off
- 39 Before you turn on the radar for the first time
- 39 Turn the radar on
- 39 Turn the radar off
- 40 Configure the navigator communications
- 40 Heading sensor requirements
- 40 Disable the heading sensor input
- 41 Calibrating the radar
- 41 Prepare for calibration
- 41 Tune the radar
- 41 Set the STC Curve
- 42 Set the trigger delay
- 42 Set the heading calibration (heading sensor installed)
- 43 Set the heading calibration (heading sensor not installed)
- 43 Adjust the appearance settings
- 44 Restore all the factory settings
- 44 Restore the factory appearance settings
- 45 General maintenance
- 45 Scanner maintenance
- 45 Other maintenance items
- 46 Technical support, service and repairs
- 46 Radar is not operating correctly
- 47 If the scanner fails to turn
- 47 How to reduce noise and interference
- 48 Make sure the power is present and correctly wired
- 48 Confirm the equipment installed
- 48 Are Range Rings displayed?