Connect the radar communications cable (NS003107) to the junction box. North Star 10 kW, 25 kW


Add to my manuals
53 Pages

advertisement

Connect the radar communications cable (NS003107) to the junction box. North Star 10 kW, 25 kW | Manualzz

B

C

F

G

I

To NMEA Device 1

To NMEA Device 2

Circuit breaker/fuse box

Optional radar communications extension cable (NS003108)

NTSC Video Input

L Power

M NMEA

N Ethernet

0 AUX

12.7.1 Connect the radar communications cable (NS003107) to the junction box

The free ends of the radar communications cable (NS003107) must be terminated in a junction box

(see the figure in the previous section). The junction box is not supplied.

The communications cable has a 0.41" (10.5 mm) diameter. The junction box must be waterproof and large enough to contain a 20 way strip connector.

All cable entry points should use suitable grommets or glands to ensure that waterproofing is maintained.

The table shows the wiring and pin details of the radar communications cable. The naming convention for the bi-colored wires is primary color/stripe; for example, White/Orange refers to a white colored wire with an orange stripe.

If the radar processor is connected through the 12-pin NMEA/Comms connector on the radar communications cable (NS003107), then all of the NMEA 2 free end signals and grounds must be NO CONNECT in the junction box.

If a SmartCraft device is connected through the 8 pin SmartCraft connector on the radar communications cable

(NS003107), then all the RS-232 free end signals and grounds should be NO CONNECT in the junction box.

NMEA devices must be connected to an unused NMEA port on the connector strip.

The remote power signal configuration is explained in "Configure the remote power control for a

6000i or 6100i (common power source)" and "Configure the remote power control for a 6000i or 6100i

(different power sources)".

Wire function

NMEA 1 IN A

NMEA 1 IN B

NMEA 1 IN GROUND

NMEA 1 OUT A

NMEA 1 OUT B

Free end

Brown

Blue

White/Blue

Violet

Gray

Connector 1

6000i/6100i NMEA

4

12

7

Pin

3

1

Color

Brown

Blue

White/Blue

Violet

Gray

Connector 2

NMEA/Comms

Pin Color

Connector 3

Smartcraft

Pin Color

Northstar 25 kW Radar Installation Manual 31

NMEA 1 OUT GROUND

NMEA 2 IN A

NMEA 2 IN B

NMEA 2 IN GROUND

NMEA 2 OUT A

NMEA 2 OUT B

Blue/White

White/Brown

Brown/White

White

Yellow

Orange

8

6*

2*

5*

15*

11*

Blue/White

White/Brown

Brown/White

White

Yellow

Orange

2

7

8

1 Green

Red

Orange

Blue

NMEA 2 OUT GROUND

RS-232 GROUND

RS-232 RX

RS-232 TX

REMOTE SAVE

Black 10 Black

Tan

Green

Red

17*

16*

18*

Tan

Green

Red

Orange/White 13 Orange/White

Pink 14

12 Yellow

6000i or 6100i REMOTE

POWER OUT

SHIELD

RADAR REMOTE POWER

IN

White/Orange

* See cautions on previous page.

10 Brown

1 White

3 Green

8 Red

The end view of the three connectors is shown:

Connector 1 - 6100i NMEA pin assignments

Connector 2 - Radar NMEA/Communications pin assignments

32 Northstar 25 kW Radar Installation Manual