advertisement
Ideally, the compass should draw less than 100 mA. (If this is not possible, power the compass using a separate 12 V source.)
12.12 Connect the power cable
The power cable to the radar processor is NOT supplied for either the 6000i or 6100i system or the
8000i system. Power must be supplied through a fuse/breaker element located at the power source end of the power cable.
Check the system specifications section for the recommended DC input voltage.
The power cable and fuse requirements are shown in the table.
Scanner
2 kW
4 kW
6 kW
10 kW
25 kW
Fuse/Circuit breaker rating
Maximum length of power cable
5 A
10 A
10 A
15 A
15 A
33 ft (10 m)
26 ft (8 m)
26 ft (8 m)
26 ft (8 m)
26 ft (8 m)
Power cable size
14 AWG
14 AWG
14 AWG
12 AWG
12 AWG
Typically the fuse /breaker would be located in a fuse/breaker box with the fuses/breakers for other devices.
The radar processor must have it's own exclusive fuse/circuit breaker. The fuse/circuit breaker should be labeled appropriately.
To connect the power cable to the radar processor, you must:
1. Strip away approximately 0.4" (10 mm) of the shielding at the end of the power cable, and then identify the positive wire and the negative wire.
2. Unscrew the small holding screw from the positive power cable input connector (identified by the + sign) on the radar processor.
3. Insert the bare ends of the positive wire into the positive power cable input connector to make a connection.
4. Tighten the small holding screw to hold the positive wire in place. Gently pull on the positive wire to ensure that it is secured.
5. Repeat this process to connect the negative wire to the negative power cable input connector (identified by the – sign).
12.13 Connect the ground wire
The radar processor has a Chassis Earth connection stud located on the far right hand side of the unit.
The Chassis Earth is DC isolated from power (–ve) to eliminate the risk of galvanic corrosion.
If you are installing the radar processor on a vessel with a metal hull, connect the radar processor
Chassis Earth to the hull at the closest possible location, using 12 AWG wire (or thicker):
Northstar 25 kW Radar Installation Manual 37
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 17 How to find the optimum height for the scanner
- 18 How to find the maximum detection range
- 19 How to reduce false echoes and shadow zones
- 19 Install an open array scanner on a trestle
- 20 25 kW radar dimensions
- 21 Install the 25 kW scanner unit
- 21 When to install the open array
- 22 Install the radar processor
- 23 Wiring guidelines
- 23 Connect the interconnection cable (NS003105/NS003106) to the 25 kW scanner
- 26 25 kW radar processor connectors
- 27 Run the interconnection cable (NS003105/NS003106) to the radar processor
- 28 Earth the 25 kW scanner
- 29 Install the 25 kW open array
- 30 Connect the 25 kW radar processor to a 6000i or 6100i display
- 31 Connect the radar communications cable (NS003107) to the junction box
- 33 Configure the remote power control for a 6000i or 6100i (common power source)
- 34 Configure the remote power control for a 6000i or 6100i (different power sources)
- 35 Connect the 25 kW radar processor to an 8000i display
- 36 Configure the remote power control for an 8000i
- 36 Connect an 8000i network cable (NS00481X)
- 36 Connect the optional NMEA compass for an 8000i
- 36 Configure the optional NMEA compass
- 37 Connect the power cable
- 37 Connect the ground wire
- 38 Radar system checklist
- 39 Turn the radar on and off
- 39 Before you turn on the radar for the first time
- 39 Turn the radar on
- 39 Turn the radar off
- 40 Configure the navigator communications
- 40 Heading sensor requirements
- 40 Disable the heading sensor input
- 41 Calibrating the radar
- 41 Prepare for calibration
- 41 Tune the radar
- 41 Set the STC Curve
- 42 Set the trigger delay
- 42 Set the heading calibration (heading sensor installed)
- 43 Set the heading calibration (heading sensor not installed)
- 43 Adjust the appearance settings
- 44 Restore all the factory settings
- 44 Restore the factory appearance settings
- 45 General maintenance
- 45 Scanner maintenance
- 45 Other maintenance items
- 46 Technical support, service and repairs
- 46 Radar is not operating correctly
- 47 If the scanner fails to turn
- 47 How to reduce noise and interference
- 48 Make sure the power is present and correctly wired
- 48 Confirm the equipment installed
- 48 Are Range Rings displayed?