Specifications (continued)

Fan Location & Speed Information

The B064-Series KVM switch contains 6 fans, whose location is shown in the image below.

Fan Speed

Fan speed is automatically adjusted according to temperature. When the temperature reaches the levels mentioned below, the KVM switches temperature sensors adjust the fan speed accordingly.

• If any of the four sensors sense a temperature greater than 32° C, all of the fans will be set to spin at half speed

• When all four sensors sense the temperature is below 30° C, all of the fans will be turned off

• If any of the four sensors sense a temperature greater than 45° C, all of the fans will be set to spin at full speed

• When all four sensors sense the temperature is below 40° C, all of the fans will be set to spin at half speed

Temperature Sensor Location

The location of the KVM switches for temperature sensors is shown in the image below.

Note: The temperature inside the case can be higher than the ambient operating temperature of the KVM switch (0° to 50° C). However, if the temperature reading shown in the Device Information section surpasses 85° C, you should either cool down the room or shut down the switch until it cools.