Electric Wiring Diagram. Pleasant Hearth L-24


Add to my manuals
33 Pages

advertisement

Electric Wiring Diagram. Pleasant Hearth L-24 | Manualzz

ELECTRIC WIRING DIAGRAM

Any electrical repairs or rewiring of this unit should be carried out by a licensed electrician in accordance with national and local codes.

CIRCUIT DIAGRAM

1 white 2 white

3 black 4 black

DANGER

Disconnect power before servicing.

Any electrical re-wiring of this appliance must be done by a qualified electrician.

This wiring must be done in accordance with local codes and/or in Canada with the current CSA Standard C22.2 No 12-1982 (R2004), and for US installations, the ANSI/UL Standard 153 12 th Ed.

If repairing or replacing any electrical component or wiring, the original wire routing, color coding and securing locations must be followed.

TROUBLESHOOTING

PROBLEM

Log set does not operate; the

ON/OFF power light on the control panel is not lit.

POSSIBLE CAUSE

1. The log set is not plugged in.

2. A circuit breaker is tripped or a fuse blown.

3. Defective ON/OFF switch.

4. Defective adaptor.

CORRECTIVE ACTION

1. Make sure the log set is plugged in to a standard 120-volt outlet and into

the base of the unit.

2. Check additional appliances on the circuit; ideally the appliance should be on a dedicated 15-amp circuit.

3. Call customer service.

4. Call customer service.