Design. Brant Radiant Heaters LR-LB1 Series

Add to my manuals
12 Pages

advertisement

  Design. Brant Radiant Heaters LR-LB1 Series | Manualzz

2.0

Specifications • Design Sample Lighting Layout

2.0

Specifications

LR-LB1 Series

Chart 2.1 • LED Bay Lighting Specifications

MODELS

LR-LB1_6PG-3W

LR-LB1_10PT-3W

LR-LB1_10PT-4W

Limited Warranty: 5-Years

DESCRIPTION

LR-LB1 Fixture with 6 ft. Plug 18/3

LR-LB1 Fixture with 10 ft. Pigtail 18/3

LR-LB1 Fixture with 10 ft. Pigtail 18/4

Watts

(w)

97

97

97

Colour

(k)

5,000

5,000

5,000

Lumens

(l)

8,600

8,600

8,600

1 Recommended mounting height allowance will depend on proper building evaluation.

Amps

(A)

Typical

Mount

0.80

8-24 ft.

1

0.80

8-24 ft.

0.80

8-24 ft.

Weight

(lbs.)

5

5

5

Product can dim from 10% to 100%

Operating temperature range: -40°C to +45°C (-40°F to 113°F).

CSA/DLC certified for indoor and outdoor applications, IP65 certified, and NEMA 4X certified.

IP Code Definition and Explanation of IP65 Rating

The IP Code, International Protection Marking, IEC standard 60529, also interpreted as Ingress Protection

Marking, classifies and rates the degree of protection provided against intrusion (body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures.

Solid Particle Protection: The first digit indicates the level of protection that the enclosure provides against access to hazardous parts (e.g., electrical conductors, moving parts) and the ingress of solid foreign objects. 6: Totally protected against dust ingress.

Liquid Ingress Protection: The second digit indicates the level of protection that the enclosure provides against harmful ingress of water. 5: Protected against low pressure jets of water from all directions - limited ingress

Design

When designing a layout for a particular application, there are several factors that should be taken into consideration.

The typical mounting height for model LR-LB1 is 8 - 24 ft. from the ground. This mounting height is a recommendation only. The facility usage purpose, colour scheme, desired brightness levels, and overall facility size will all factor into the layout of the lighting fixtures.

These LED Lighting Fixtures are NEC Class 1 compliant. Check applicable province, local, and national codes before designing and installing lighting fixtures.

A common misconception with LED lighting is the belief that they do not generate heat. While it is true that LED fixtures produce much less heat than other forms of lighting due to the increased efficiency and lower power consumption, thermal management is still a crucial component of a well-designed LED fixture. The LR-LB1 fixtures have been designed to not only enclose the LEDs and circuitry, but to act as a heat sink as well. These fixtures utilize state of the art thermal interface materials to conduct the heat from the LED module to the housing. The housing has been geometrically designed with a large surface area for excellent convection of heat away from the housing. As a result, the LR-LB1 series fixture is warranted for 50,000 hours of use within an ambient temperature of up to 45°C (113°F). For maximum long-term reliability, this light should be installed in free air.

4 5

4

LR-LB1 Series 2.0

Specifications • Design • Sample Lighting Layout

Figure 2.1 • Sample Lighting Layout - Maintenance Hangar

90.0’ Notes:

- Airplane Repair

Hanger

- 19 ft Ceiling

- Dark Walls

and Floor

- High Light Output

Desired

65.0’

Chart 2.2 • Sample Lighting Layout Statistics

Description

Airplane Hanger

Symbol

+

Avg

49.6 fc

Max

61.5 fc

Min

29.6 fc

Max/Min

2.1:1

Avg/Min

1.7:1

Chart 2.3 • Sample Lighting Layout Schedule

Symbol Label Qty.

Catalog

Number Lamp

Number

Lamps

Lumens

/Lamp Description Wattage Polar Plot

A 39

LR-LB1

(100%

Output)

144 White LEDs.

Lumen Output=

8,599 LMS.

1 8,599

Brant Radiant

Heaters

LED Bay

Luminaire

97.07

Max: 3476cd

5

advertisement