BASIC DESCRIPTION. Brave Smyle - LC, Smyle - C


Add to my manuals
58 Pages

advertisement

BASIC DESCRIPTION. Brave Smyle - LC, Smyle - C | Manualzz

6

1 BASIC DESCRIPTION

1.1 Features

 Voice communication is powered from telephone line only

 Tone (DTMF) and pulse dial

 Two 24digit numbers with each button (including *, #, Flash and Pause)

 DAY/NIGHT switching by DTMF code or automatically by integrated real time clocks - RTC, weekly schedule (C model)

 Possibility of the call extension by * or # choice

 Possibility to connect 1 or 2 (only C) independent locks for door opening

 8 different relays modes (for example: additional ring, progressive opening)

 Two codes for hanging up the unit by telephone

 Two codes for door opening by telephone for 1 pulse and two codes for

2 pulses

 3 x 6 codes for each relay (code by buttons at doors)

 Can be connected electrically secure lock on the first switch (serial activation code)

 Possible switched on hang up by press the same push button

 Possible switched on mode "Baby Call"

 Possible switched on suppress receive DTMF by microphone

 Possible switched on accoustic tick to the conversation for speech recognition

 Possible switched on accoustic signalization of close the relay

 Adjustable number of rings before pick up an incoming call

 Adjustable parameters of tone dial, length of Flash and Pause

 Adjustable parametres of acoustical signalization

 Adjustable parametres of tones detector

 Elektronical loudness settings ( without neccessity open the unit)

 Integrated analog colour camera with permanent or automatical operation /C

 Automatical camera lighting infra LED /C

 Possibility of powering by external PSU 12V (Siemens) /C (C)

 Easy settings of HW by DIP switch

 Factory settings (default) in different levels

 Programming by phone DTMF or by USB cable from PC

 Integrated heating for PCB

 Permanent cards lighting, switchable

 Ground output for better protection against static electricity

(C)

– comfort model only (Comfort)

/C - model with camera only

BRAVE

– user guide

1.2 Terminology

Telephone line analog (2 wires) is way of connection to public network

(PSTN line) or connection to PABX – telephone exchange at place of installation ( extension line)

Line picking up begin of call – same like OFF HOOK by handset

Line hanging up end of call – same like ON HOOK by handset

Dial

Incoming call

DTMF - tone dial. It is dial by 2 tones combination (dial also special character * and #. Use Flash loop interruption)

Pulse – dial by loop interruption (dial numbers only) connection between intercom and phone has been done by

Outgoing call dial from phone.The intercom picks up the call after preprogrammed number of rings. After picking up and password inserting you can programm the unit by phone. connection between intercom and phone has been done by dial from intercom, for example : by button pressing

Call establishing it is stage when call is picked up by called party. This stage is not signalled at analog line. It just stop ringing tone and

El.lock code

Code relay call starts. It is difficult identify just this moment. function for relay closing by dial digits combination from intercom buttons between Doorphone Brave and the electric lock can be connected code relay (COSW - CodeSwitch), which is code on the board relay (COSW).

External code Digits combination dial from intercom buttons for relay activation. External = dial by intercom buttons – out of building ( at place of door intercom installation)

Internal code located at the lock and lock activates only when is the same the specified serial combination of the Brave and set the

Digits combination dial from phone for relay activation

(DTMF). Internal = dial by phone – inside building ( phone connected to other PBX extension)

The manufacturer continuously improves the product firmware. The technology used allows you to upload to Brave the latest version of the firmware any time using a standard computer with BraveSet and USB cable. The latest version of the firmware is available at http://www.alphatech.cz

BRAVE

– user guide

7

1.3 Different Models of Smyle Brave door intercom

Brave door intercoms is designed as new generation of door intercom units reflects all experiences collected during last 10 years of succesfull sales of door enry solutions. Features and parametres are different for different models of intercom to provide best balance between price and usage value.

In this manual you will meet features and parametres marked by (C) which are specific for Brave Smyle (Comfort) model only and features and parametres marked (M) which are planned for modular model (in Smyle solution are not provided due mechanical solution)

Labelling of availability function :

Model LC (low cost) has all features except particularly marked

Model /C is version equiped by full colour analog camera

Model C (comfort) has special features marked by (C)

Model M (modular) has marked (M) – in mechanical Smyle solution is not produced! And it is mentioned in programming tables only which are same for all models.

1.4 Models of Brave door intercom

SMYLE models of Brave LC/C includes appropriate mother board with all connectable elements.

Brave Smyle - 01C Brave Smyle - 01C/C Brave Smyle

– 02C Brave Smyle – 2C/C

Brave Smyle - 01LC Brave Smyle

– 02LC

Models LC and C are different up mother board components. In model (LC) is missing:

Second relay

RTC real time clocks for automatic DAY/NIGHT switching

Models with camera /C have added:

Possibility of external powering (usable for relay modes 7 and 8)

 automatical / permanent lighting for camera (infra)

 switch off cards lighting

 disconnectable internal impedance for camera cable ending 75ohm

8 BRAVE

– user guide

1.5 PCB Schematics

All functional and connectional elements are marked by red rounded number at bellow picture. Explanation follow on next page.

Pict. 1 Brave Smyle mother board

(1) + (3) + (7) + (11) - version /C only relay 2 version (C) only

BRAVE

– user guide

9

1. Camera lighting - infra LED. It lights up space before camera when is active.

It is possible switch off (via. item 7) – version for camera only /C

2. Connector to PC connection via USB cable

3. Analog colour camera – version with camera /C only

4. Speaker connection

5. Microphone connection (caution on polarity)

6. DIP switch in all models:

1 = Service, usage – when programming password is forgotton. Incoming call is going directly to programming mode where you can set new password.

2 = Heating

– switch ON integrated heating of mother board to increase resistance against condensation water during changes of temperature

7. DIP switch position in versions (C) and /C:

3 = external power supply

4 = external power supply – switching 3 and 4 simultaneously. The powering is used from screw 12V (11) due following reasons:

- using relay mode 7 or 8 – tpermanent switching ON/OFF is possible only with external power supply. Dont forget setup parametr 64.

- Connection of door intercom to certain type of PBX which has problems with current consumption on its extensions during start (Siemens).

5 = Camera lighting up (switch ON/OFF lighting of space before camera via infra

LED)

6 = Cards lighting (switch ON/OFF Leds backlighting for cards beside button)

7 = Activate permanent camera operation. In default camera is active only when door intercom is active.

8 = Allows connect 75ohm to camera output - impedance

8. Analog telephone line (not depends on polarity)

9. Grounding – connection to ground of static electricity protection – protects electronic of door intercom as same as PBX

10. Relays are galvanically isolated - max. 48V, max. 1,5A model (C) has 2 relays model (LC) has 1 relay only on switch 1 is available relay function code (COSW - CodeSwitch) (see

page16)

11. Camera output - PAL video 1V / 75ohm. For distance longer than 25m we recommend coax cable. For other installation UTP cable is also available.

/C

model only

12. 12V power supply: - relays control

- mother board heating

- cards backlighting

- camera powering and infra LED camera lighting up

- external powering of unit (DIP 3 and 4)

The power supply might be AC as same as DC, not depends on polarity, max consumption 250mA from 12V.

The power supply might be used also for electrical lock powering. Then we recommend power supply 12V/1A.

10 BRAVE

– user guide

You can also use 24V DC power supply. It is useful mainly at installations where power supply is already installed and it is used for sliding doors,

RFID, etc.. The heating has control element to restrict power.

The remaining components are designed for voltage up 24V DC!!!

It not depends on polarity.