3 Door intercom service

Functionality of Brave Smyle door inercom is adjustable by parametres

settings (via. Programming parametres capture page 26).

3.1 Signalling overview

The Brave Smyle door intercom signalling acoustically stages which are happening during operation. Samples of acoustical sounds you can play in

BraveSet ( PC programm).

Stage Tones Tone frequency

Line pick up ( OFF HOOK) type 1

Line hang up ( ON HOOK) type1

Line pick up ( OFF HOOK) type 2

Line hang up ( ON HOOK) type2

Command confirmation by phone

Alerting (knocking) into call

Call ending alert

Relay activation signal

Programming enter by phone

Programming by phone

Parametr confirmation

Programming enter by PC

Line connection (Reset)

Error (generally all incorrects)

–▄■▄■▀–

–▀■▄■▄–

–▄■▀–

–▀■▄–

––█––

─┴─┴─

–■–■–■–

─▒▒▒▒▒▒─

–▄■▀–

––▓–▓–––––

––█––

–▄■▀–

–■–▄–■–

–■–■–■–■–■–■–

980-1333-1650

1650-1333-980

800-1067-1200-1333

1333-1200-1067-800

800

1333

Modulovaný

980-1067-1180

Modulov aný

800

980-1067-1180

1850-1067-1850

800

Memory empty (no number programmed) –▄■▄■▄■▄■– 1300-2100

During problems identification is very good when you know the tones. It helps you monitor how door intercom works and where from comes the problem.

The signalling might be switch of in a few levels (parametres 61,62,63 and 65).

BRAVE

– user guide

21

3.2 Visitor at the door

Door intercom buttons have signs (cards) like usual ring buttons. Visitor find desired name ( for example“Scott") and push it. The Brave intercom pick up the line and "play" tone line pick up (when is not switch off by par.62) and dial phone number saved under the button (parametr 1 or 2 up door intercom mode).

From Brave intercom speaker you hear ringing tone and phone of Mr. Scott is ringing. As soon as Mr. Scott pick up ringing phone he can talk to visitor at the door. When is electrical lock connected to Brave intercom then Mr. Scott can open the door for visitor by dial DTMF code on his phone. When Mr. Scott hang up the phone then Brave intercom hangs up as well after busy tone detection.

When call duration is longer then setup limit (parametr 52) the 10sec before hang up Brave intercom sends alerting tone of call ending. Mr. Scott can dial * or # up setting (parametr 42) to prolong the call about the time setup by

parametr 52.

Dialled number from Brave intercom is different up dial mode setup in the unit by (parametr 47):

- Day/Night mode = when intercom is in DAY mode then number setup by

parametru 1 is dialled. When intercom is in NIGHT mode then always dial number setup by parametr 2. Manual intercom modes switching is setup by parametres 45,46. In version (C) you can switch DAY/NIGHT mode automatically. Selection of dialled number saved under the button is control by time up table (parametry 00-06).

- 2 groups numbers mode = first button push – always dial number setup by parametr 1. When the same button is pushed or 10seconds after dial busy tone is detected, or setup number of rings is out (parametr 56) the door intercom dial number from second group setup by (parametr 2). When you push the same button again you will dial again number from first group etc.

……(when after dial number from second group busy tone is detected the repeating is finished)

When visitor push the button after line is picked up the door intercom hangs up for time setup by parametr 54 and then picks up the line and dial new number ( second push number). The number dialling is either by tone dial

(DTMF) or pulse dial up setting by parametr 41. There is one more option and it is line hangs up by again pushing of same button (parametr 4*).

You can control relay(s) by door intercom buttons (code lock). When visitor push buttons in order which match to setup code (parametr 32-34) and time between each button press is not longer than setup by (parametr 53) then door intercom picks up and activate appropriate relay (when relay setup is mode m=1 or m=5) for time setup by parametr 37 eventually.39,30. Then hangs up.

The relay (up control code) can activate one pulse or two pulses with time

between each pulse setup by parametr 30 via. Tab. 1.

22 BRAVE

– user guide

mode m = 1 (parametr 3111 and 3121)

Action Note Parametr Relay

Evaluation of correct external code from buttons

According settings

DAY/NIGHT

According settings

DAY/NIGHT

According settings

DAY/NIGHT

According settins

DAY/NIGHT

3211-3215

3311-3315

3411-3415

3221-3225

3321-3325

3421-3425

321*

331*

341*

322*

332*

342*

Internal code from phone

351

You can dial 1 or 2 numbers of code

2digits code is default

You can shorter it by using * on first digit of code during programming

352

361

362

Mode m = 5 (parametr 3125)

Action Note

Evaluation of correct external code from buttons

According settings

DAY/NIGHT

According settings

DAY/NIGHT

According settings

DAY/NIGHT

According settings

DAY/NIGHT

Internal code from phone You can dial 1 or 2 numbers of code

2digits code is default

You can shorter it by using * on first digit of code during programming

Parametr Relay

3211-3215

3311-3315

3411-3415

3221-3225

3321-3325

3421-3425

321*

331*

341*

322*

332*

342*

351

352

361

362

BRAVE

– user guide

23

mode m = 4

Action

Button push

Note

Any button different from

311* or 312*

Parametr

3114

3124

Relay

3114

Button setup by 311* or

312*

3124

Mode m = 6

Action

Button push

Note

Any button different from

311* or 312*

Parametr

3116

3126

Relay

-

-

3116

Button setup by 311* or

312*

3126

Poznámka: t1 – time activation 1 of relay (parametr 371) t2 – time between pulses 1 of relay (parametr 301) t3 – time between activation 1 and 2 relay (parametr 39) t4

– time activation 2 of relay (parametr 372) t5 – time between pulses 1 of relay (parametr 302)

Tab. 1 Table of relay(s) control

3.3 Person inside building

By person inside building we mean person in telephone connection with

Brave intercom , for example Mr. Scott.

3.3.1 Outgoing call

Outgoing call is a call from door intercom (generated by visitor). After door intercom dial is ringing a phone inside the building. When you pick up the phone you can talk to visitor. By code dialling you can activate the relay (parametr 35) when relay is setup in mode m=1 or m=5. You also can switch operation mode

DAY/NIGHT (parametr 45,46) and hang up (parametr 43). Door intercom sends

10sec before call ending (parametr 52) alerting tone and you can prolong the call by dialling special character from phone (parametr 42). By phone hanging up the call is ended (PBX generates busy tone into the line which is detected and door intercom hangs up). There is one more option which is hang up the line by again push of the same button (parametr 4*).

24 BRAVE

– user guide

3.3.2 Incoming call

Incoming call is a call into door intercom (generated by person inside the building). After dialling extension number where is connected door intercom the door interocm line is ringing. After setup number of rings the door intercom picks up (parametr 51) and you can talk. Other

possibilities are the same like in case of outgoing call (capture 3.3.1).

First exception is first 10sec where you can dial "# and service password"

(parametr 44). By this you enter programming mode of door intercom.

Second exception is when DIP1 is switch to position ( "SERVIS" ). Then you enter programming mode directly without dialling service password.

Last exception is relay(s) control (parametr 381 and 382). You can by programming prohibit to control relay(s) from incoming call .

3.4 Acoustic path setting

The principle of setting acoustic paths:

Here we have three parameters 71.72 and 73 Using the interaction of these parameters can be set to sound in different conditions.

1. quiet environment parameters 71,72,73 are set to 7

2. environment where is a strong ambient noise at the communicator and quiet environment at the phone. Here is both necessary to reduce the microphone gain (parameter 72 = 1-3) and also change the ratio of the parameters 71/73 way 73 enlarge the the parameter (parameter 73 = 11-15) and 71 parameter smaller value (71 = 2-4)

3. environment where is a strong ambient noise at the phone and quiet environment at the communicator. Here we leave the parameter value of 72

= 7 and 73 and 71 parameters set as follows - parameter71 = 11 to 14 and

73 = 2 to 4

The principle of settin parameters is - signal from the microphone is amplified by the sum of parameters 72+71 = volume of microphone and signal to the speaker is amplified by the sum of parameters 71+73 = volume of speaker. To switch the direction of the ratio is evaluated parameters (threshold) 73/72.

- If parameter 72 is greater than the parameter 73, thus favoring the direction from the microphone. We choose when the direction to the phone is interrupted.

- If parameter 73 greater than parameter 72, thus favored direction to the speaker. We choose this if the interrupted sound in the speaker of communicator.