Common specifications
6.2 Common specifications
tion Control method
Power supply frequency range
PWM control
50Hz to 60Hz
Current limit level Current limit value selectable (0 to 220% variable)
Input signal (Five terminal)
Output signal
Open collector output (Five terminals)
Relay output (One terminal)
Operating status
The following signals can be assigned to Pr. 3 to Pr. 7 (input terminal function selection) : converter stop, monitor switching, converter reset, external thermal relay, and inrush resistance overheat detection.
The following signals can be assigned to Pr. 11 to Pr. 16 (output terminal function selection) : inverter run enable signal, converter reset, converter running, overload alarm, power supply phase detection, output voltage match, instantaneous power failure detection, regenerative drive recognition, electronic thermal relay pre-alarm, fan alarm, heatsink overheat pre-alarm, during retry, input current detection, zero current detection, life alarm, maintenance timer, instantaneous power failure detection hold, alarm, and fault output.
For meter
Pulse train output
(Max. 2.4kHz: one terminal)
Analog output
(Max. 10VDC: one terminal)
The following signals can be assigned to Pr. 54 FM terminal function selection (pulse train output) and Pr. 50 AM terminal function selection (analog output) : power supply frequency, input current, input voltage, converter output voltage, electronic thermal relay load factor, input power, reference voltage output.
Operation panel
(FR-DU07-CNV)
Operating status
Power supply frequency, input current, input voltage, fault or alarm indication, converter output voltage, electronic thermal relay load factor, cumulative energization time, cumulative power, input power, input power (with regenerative display), I/O terminal status
, power/regenerative drive indication
Fault definition is displayed when a fault occurs. Past eight fault records and the data right before the fault (input voltage/current/bus voltage/cumulative energization) are stored.
Parameter unit
(FR-PU07)
Fault record
Interactive guidance
Function (help) for operation guide
Protective/warning function
Protective function
Warning functions
Surrounding air temperature
Ambient humidity
Atmosphere
Overcurrent, overvoltage, converter protection thermal, fin overheat, instantaneous power failure, undervoltage, input phase loss, HC2 dedicated board disconnection, input power
supply fault, external thermal relay operation
, parameter error, PU disconnection
, retry count excess
converter CPU fault, operation panel power supply short circuit,
24VDC power output short circuit, input current detection value exceeded
, inrush current limit circuit fault, internal circuit fault, option fault
, communication option fault
.
Fan alarm, overload signal detection, electronic thermal relay pre-alarm, PU stop,
, parameter write error, copy operation error, operation panel
lock, parameter copy alarm, no-phase detection
-10 C to +50 C (non-freezing)
90%RH or less (non-condensing)
-20 C to +65 C
Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt etc.)
Altitude/ vibration
Maximum 1,000m above sea level, 5.9m/s
2
or less
at 10 to 55Hz (directions of X, Y, Z axes)
Can be displayed only on the operation panel (FR-DU07-CNV).
Can be displayed only on the option parameter unit (FR-PU07).
Temperature applicable for a short time, e.g. in transit.
This protective function is not available in the initial status.
This protective function is enabled when FR-A7NC is mounted.
2.9m/s
2
or less for the 160K or higher.
149
6
advertisement
Related manuals
advertisement
Table of contents
- 9 1.1 Pre-operation instructions
- 9 Features of FR-HC2 (high power factor converter)
- 9 Japanese harmonic suppression guideline
- 12 Product checking and parts identification
- 14 1.2 Converter and peripheral devices
- 15 1.3 Precautions for selecting peripheral devices
- 15 Measures against noises (EMI)
- 18 Peripheral device list
- 21 Selecting the rated sensitivity current for the earth leakage circuit breaker
- 23 2.1 Removal and installation of the converter (FR-HC2) front cover
- 25 cover
- 26 2.3 Installation
- 26 Converter placement
- 28 2.4 Protruding the heatsink
- 28 When using a heatsink protrusion attachment (FR-A7CN)
- 28 Heatsink protrusion for 160K or higher
- 30 2.5 Installation of peripheral devices
- 30 Installation of reactor 1 and reactor
- 31 Installation of the outside box (FR-HCB2-7.5K to 75K, FR-HCB2-H7.5K to H220K)
- 32 Installation of filter capacitor (FR-HCC2-H280K to H560K)
- 32 Installation of inrush current limit resistor (FR-HCR2-H280K to H560K)
- 33 Installation of MC power supply stepdown transformer (FR-HCM2-H280K to H560K)
- 34 2.6 Main circuit terminal specifications
- 34 Description of main circuit terminal
- 35 Terminal arrangement of the main circuit terminal
- 38 Cable sizes of the main control circuit terminals and earth (ground) terminals
- 41 (FR-HC2-7.5K to 75K, FR-HC2-H7.5K to H220K)
- 41 Connection diagram (when using with the FR-A700 series)
- 42 Wiring of main circuit
- 48 2.8 Wiring of main circuit (FR-HC2-H280K)
- 48 Connection diagram (when using with the FR-A700 series)
- 50 Wiring of main circuit
- 54 2.9 Wiring of main circuit (FR-HC2-H400K, H560K)
- 54 Connection diagram (when using with the FR-A700 series)
- 55 Wiring of main circuit
- 60 2.10 Notes on earthing (grounding)
- 61 2.11 Compatible inverter for the high power factor converter
- 61 2.11.1 Applicable inverter capacity
- 62 2.11.2 Inverter parameter settings
- 63 2.12 Wiring of several inverters to one converter
- 65 2.13 Wiring of control circuit
- 65 2.13.1 Description of control circuit terminal
- 67 2.13.2 Changing the control logic
- 69 2.13.3 Control circuit terminal layout
- 70 2.13.4 Wiring instructions
- 71 2.13.5 When connecting the operation panel or parameter unit using a connection cable
- 71 2.13.6 Communication operation (computer link operation)
- 73 3.1 Operation panel (FR-DU07-CNV)
- 73 Names and functions of the operation panel (FR-DU07-CNV)
- 74 Basic operation (factory setting)
- 75 Changing the parameter setting value
- 76 parameter unit with battery pack (FR-PU07BB(-L))
- 76 Parts identification of the parameter unit
- 76 Explanation of keys
- 77 Monitoring function
- 78 Function menu
- 80 3.3 Parameter list
- 82 3.4 Description of parameters
- 82 Displaying and hiding extended parameters (Pr. 0)
- 82 Input frequency to converter (Pr. 1, Pr. 2)
- 83 Input terminal function selection (Pr. 3 to Pr. 7)
- 84 Operation selection of SOF signal and OH signal (Pr. 8, Pr. 9)
- 85 Output terminal function selection (Pr. 10 to Pr. 16)
- 86 DC voltage control (Pr. 22 to Pr. 24, Pr. 80, Pr. 81)
- 87 Input current detection function (Y12 signal, Y13 signal, Pr. 25 to Pr. 30)
- 88 Displaying the life of the converter parts (Pr. 31 to Pr. 33)
- 89 Maintenance timer alarm (Pr. 34, Pr. 35)
- 90 3.4.10 Cooling fan operation selection (Pr. 36)
- 90 3.4.11 Instantaneous power failure detection hold (Pr. 44)
- 91 Pr. 51, Pr. 53, Pr. 55, Pr. 56)
- 93 3.4.13 DU/PU, terminal FM/AM monitor display selection (Pr. 46 to Pr. 48, Pr. 50, Pr. 52, Pr. 54)
- 96 3.4.14 Operation selection at instantaneous power failure (Pr. 57)
- 97 3.4.15 Free parameter (Pr. 58, Pr. 59)
- 97 3.4.16 Key lock selection of operation panel(Pr. 61)
- 98 3.4.17 Retry function (Pr. 65, Pr. 67 to Pr. 69)
- 99 3.4.18 Reset selection/disconnected PU detection/PU stop selection (Pr. 75)
- 101 3.4.19 Parameter write disable selection (Pr. 77)
- 102 3.4.20 Current control (Pr. 82, Pr. 83)
- 102 3.4.21 Wiring and configuration of PU connector
- 104 3.4.22 Initial settings and specifications of RS-485 communication (Pr. 117 to Pr. 124)
- 105 3.4.23 Mitsubishi inverter protocol (computer link communication)
- 116 3.4.24 Initial setting and specification for the CC-Link communication function (Pr. 542 to Pr. 544)
- 122 3.4.25 Operation at a communication error (Pr. 500 to Pr. 502)
- 123 3.4.26 Communication EEPROM write selection (Pr. 342)
- 124 3.4.27 Setting of the parameter unit and operation panel (Pr. 145, Pr. 990, Pr. 991)
- 125 3.4.28 Terminal FM and AM calibration (calibration parameter C0 (Pr. 900), C1 (Pr. 901))
- 127 3.5 Parameter clear / All parameter clear
- 128 3.6 Parameter copy and parameter verification
- 131 4.1 Troubleshooting
- 131 4.2 Reset method of protective function
- 132 4.3 List of fault and alarm indications
- 133 4.4 Causes and corrective actions
- 140 4.5 Correspondences between digital and actual characters
- 141 4.6 Check and clear of the faults history
- 143 4.7 Check first when you have a trouble
- 145 5.1 Inspection items
- 145 Daily inspection
- 145 Periodic inspection
- 146 Daily and periodic inspection list
- 147 Checking the converter module
- 147 Cleaning
- 148 Replacement of parts
- 152 5.2 Measurement of main circuit voltages, currents and powers
- 153 Insulation resistance test using megger
- 153 Pressure test
- 155 6.1 Rated specifications
- 156 6.2 Common specifications
- 157 6.3 Outline dimensions
- 157 Converter (FR-HC2)
- 164 Reactor 1 (FR-HCL21)
- 172 Reactor 2 (FR-HCL22)
- 179 Difference between the reactor 1 (FR-HCL21) and the reactor 2 (FR-HCL22)
- 179 Outside box (FR-HCB2)
- 186 Filter capacitor (FR-HCC2)
- 188 FR-HCM
- 192 Inrush current limit resistor (FR-HCR2)
- 193 Parameter unit
- 195 Appendix 1 Instruction code list
- 196 Appendix 2 Instructions for compliance with the EU Directives
- 198 Appendix 3 Instructions for UL and cUL