Features

1

Greatly suppressed power supply harmonics

 The HC2 converters, being the self-excitation three-phase bridge circuit under "the Harmonic Suppression Guidelines for Specific

Consumers", take the conversion coefficient of the equivalent capacity (K5 = 0).

Harmonic Conversion Coefficient of the Equivalent Capacity

(Excerpt from the Guidelines Appendix)

Classification

1

3

4

5

Three-phase bridge

Three-phase bridge

(smoothing capacitor)

Circuit type

6-pulse converter

12-pulse converter

24-pulse converter

Without a reactor

With a reactor (on AC side)

With a reactor (on DC side)

With reactors (on AC/DC sides)

Single-phase bridge

(smoothing capacitor, double voltage rectification)

Single-phase bridge

(smoothing capacitor, full-wave rectification)

Self-excitation three-phase bridge

Without a reactor

With a reactor (on AC side)

Without a reactor

With a reactor (on AC side)

Conversion coefficient

K11 = 1

K12 = 0.5

K13 = 0.25

K31 = 3.4

K32 = 1.8

K33 = 1.8

K34 = 1.4

K41 = 2.3

K42 = 0.35

K43 = 2.9

K44 = 1.3

K5 = 0

Application examples

Railway substation

Electro-chemistry

Others

General-purpose inverter

Lift

Refrigerator and air conditioner

Others

General-purpose inverter

Refrigerator and air conditioner

Others

General-purpose inverter

Others

PWM converter (high power factor converter)

 The waveform with high peaks, which is typical of inverter's input current, is reshaped to be a sine wave with lower input current effective values.

 The lowered effective value enables adoption of smaller power-supply-side devices, such as a power supply transformer, MCCB, and cables. Such smaller equipment saves the cost of equipment.

Power supply voltage

Input current

Power supply voltage

Input current

4

2

Power regeneration function for energy saving

The power regeneration function, which comes as a standard feature, eliminates the need for brake units. The power regeneration function gives a great breaking capability.

(Regeneration is available continuously with 100% torque, and for 60s with the maximum of 150% torque.)

The regenerative power from the motor is returned to the power source, and such a system significantly saves energy.

7.5K

15K 30K 55K

500

300

200

100

50

30

10

10 20 30 40 50 60 70 80

Short-time permissible regenerative power (kW)

[55K or lower]

3

Connectable to multiple inverters

Inverter The common converter method enables the connection to up to

10 inverters.

* 1

The power returned during regenerative driving can be supplied to another inverter, saving the overall energy.

FR-HC2

Inverter

Max.10 units connectable

*1 : Be sure to use a high power factor converter with the capacity higher than the total capacity of the inverters or the total capacity of the motors.

(Refer to page 12.)

Inverter

[Without FR-HC2] [With FR-HC2]

4

Compact design for space saving

The high power factor converters (excluding 15K) and input reactors (75K or higher) have become much smaller than their conventional models (FR-HC, MT-HC).

5

Long life parts and life diagnosis function

(1) Longer life parts

 The service life of the cooling fans is now 10 years * 1 and that can be even longer with the ON/OFF control of the cooling fan.

 Capacitors with a design life of 10 years * 1 * 2 are adapted.

(Using a surrounding air temperature of 105˚C for 5000 hours). With these capacitors, the service life of the converter is further extended.

*1 : Surrounding air temperature: Annual average of 40ºC (free from corrosive gas, flammable gas, oil mist, dust and dirt).

The design life is a calculated value and is not a guaranteed product life.

*2 : Input current: 80% of the high power factor converter rating

 Estimated service lifespan of the consumable parts

Part name

Cooling Fan

Estimated lifespan

10 years

Reference value by JEMA * 3

2 to 3 years

Main circuit smoothing capacitor 10 years 5 years

Smoothing capacitors on the printed board 10 years 5 years

*3 : Excerpt from "The Periodic Inspection Recommendations on General-purpose

Inverters" by the Japan Electrical Manufactures Association (JEMA).

(2) The leading-edge life diagnosis function

 The degree of deterioration of the main circuit capacitor, cooling fan, and inrush current limit circuit can be diagnosed on the monitor.

 Using the self-diagnosis function, the part life warning can be output and the deterioration degree can be monitored.

Thus, the self-diagnosis function prevents troubles from occurring.

*4 : A warning is output when any of the control circuit capacitor, inrush current limit circuit, and cooling fan reaches its output level.

Features

6

Operation panel equipped with the setting dial

(FR-DU07-CNV)

 Parameters can be copied using the operation panel

(FR-DU07-CNV).

The setting values of the parameters can be stored to the operation panel and the option parameter unit (FR-PU07).

 Items such as input current, input voltage, input power (with the regenerative display), bus voltage, etc. can be monitored.

 Operation can be easily performed with the setting dial.

Parameter change example

7

Supporting more network protocols

 HC2 supports RS-485 as a standard. With the option

FR-A7NC, HC2 also supports CC-Link.

•The power can be monitored during driving/regenerative driving, and this monitoring tells you the energy saving effect.

•Alarm functions and voltage monitors of each phase help you to spot the cause of the alarm.

FR-HC2 Inverter Inverter

Programmable controller

Terminating resistor

FR-A7NC FR-A8NC

CC-Link dedicated cable

CC-Link network

FR-A8NC

Terminating resistor

Applications

[Ceiling crane]

G

Trolley line

Trolley line

IM

Hoisting motor

IM

Crane

IM G

W

Rail

Power supply

Standard accessories

High power factor converter

(FR-HC2)

Inverter

Traveling motor

Inverter

Inverter

B

B

Traveling motor

Hosting motor

B

• The power regeneration function is installed. A brake

unit is not required.

•The mechanical brake is powered from the power

supply side of the standard accessories.

[Water treatment plant (pump)]

Power supply

Standard accessories

High power factor converter

(FR-HC2)

Inverter

Inverter

• Power supply harmonics of inverters can be

suppressed.

• The power regeneration function is installed.

A brake unit is not required.

Motor

Motor

Protective functions dimension drawings

Option and peripheral

Extensive lineup

Model

F R - H C 2 - 7.5K

High power factor converter basic model name

Capacity (kW)

Three-phase 200V class

Three-phase 400V class

7.5

15

30

Symbol

No sign

H

55

Voltage

200V class

400V class

75

Symbol

7.5K to 560K

Applicable capacity

Represents the capacity kW.

110

160

220

280

400

560

    

 : Available model −: Not available

Compliant with UL, cUL, EC Directives (CE marking), and Radio Waves Act (South Korea, KC marking).

Also, certified as compliant with the Eurasian Conformity (EAC).

The high power factor converters are compliant with the EU RoHS Directive (Restriction of the Use of Certain Hazardous Substances in

Electrical and Electronic Equipment), friendly to people and to the environment.

To obtain higher environmental resistance, the FR-HC2 has coated printed circuit boards and copper plated conductors. Magnetic contactors also have anti-corrosive coatings on.

The coated printed circuit board model (FR-HC K-60) of the conventional series is replaceable with the standard model of this series.

[Note]

• These coating treatments do not guarantee an operation environment beyond the range indicated in the product specification.

• Coating is applied to the printed circuit board areas excluding its LEDs, connectors, terminal blocks and their peripherals, where coating cannot be applied.

• As for the anti-corrosive treatment of the magnetic contactor, plating is applied to the copper areas where no surface treatment is applied.

Standard accessories

Refer to page 9

Precaution on selection and

High power factor converter * 1

(FR-HC2)

Reactor 1

(FR-HCL21)

Reactor 2

(FR-HCL22)

Outside box * 2

(FR-HCB2)

*1 : Use in combination with standard accessories. Cables for connecting standard accessories are not provided.

*2 : Peripheral devices are separately provided for 280K or higher (not provided as the outside box).

5

Features

1

Greatly suppressed power supply harmonics

 The HC2 converters, being the self-excitation three-phase bridge circuit under "the Harmonic Suppression Guidelines for Specific

Consumers", take the conversion coefficient of the equivalent capacity (K5 = 0).

Harmonic Conversion Coefficient of the Equivalent Capacity

(Excerpt from the Guidelines Appendix)

Classification

1

3

4

5

Three-phase bridge

Three-phase bridge

(smoothing capacitor)

Circuit type

6-pulse converter

12-pulse converter

24-pulse converter

Without a reactor

With a reactor (on AC side)

With a reactor (on DC side)

With reactors (on AC/DC sides)

Single-phase bridge

(smoothing capacitor, double voltage rectification)

Single-phase bridge

(smoothing capacitor, full-wave rectification)

Self-excitation three-phase bridge

Without a reactor

With a reactor (on AC side)

Without a reactor

With a reactor (on AC side)

Conversion coefficient

K11 = 1

K12 = 0.5

K13 = 0.25

K31 = 3.4

K32 = 1.8

K33 = 1.8

K34 = 1.4

K41 = 2.3

K42 = 0.35

K43 = 2.9

K44 = 1.3

K5 = 0

Application examples

Railway substation

Electro-chemistry

Others

General-purpose inverter

Lift

Refrigerator and air conditioner

Others

General-purpose inverter

Refrigerator and air conditioner

Others

General-purpose inverter

Others

PWM converter (high power factor converter)

 The waveform with high peaks, which is typical of inverter's input current, is reshaped to be a sine wave with lower input current effective values.

 The lowered effective value enables adoption of smaller power-supply-side devices, such as a power supply transformer, MCCB, and cables. Such smaller equipment saves the cost of equipment.

Power supply voltage

Input current

Power supply voltage

Input current

4

2

Power regeneration function for energy saving

The power regeneration function, which comes as a standard feature, eliminates the need for brake units. The power regeneration function gives a great breaking capability.

(Regeneration is available continuously with 100% torque, and for 60s with the maximum of 150% torque.)

The regenerative power from the motor is returned to the power source, and such a system significantly saves energy.

7.5K

15K 30K 55K

500

300

200

100

50

30

10

10 20 30 40 50 60 70 80

Short-time permissible regenerative power (kW)

[55K or lower]

3

Connectable to multiple inverters

Inverter The common converter method enables the connection to up to

10 inverters.

* 1

The power returned during regenerative driving can be supplied to another inverter, saving the overall energy.

FR-HC2

Inverter

Max.10 units connectable

*1 : Be sure to use a high power factor converter with the capacity higher than the total capacity of the inverters or the total capacity of the motors.

(Refer to page 12.)

Inverter

[Without FR-HC2] [With FR-HC2]

4

Compact design for space saving

The high power factor converters (excluding 15K) and input reactors (75K or higher) have become much smaller than their conventional models (FR-HC, MT-HC).

5

Long life parts and life diagnosis function

(1) Longer life parts

 The service life of the cooling fans is now 10 years * 1 and that can be even longer with the ON/OFF control of the cooling fan.

 Capacitors with a design life of 10 years * 1 * 2 are adapted.

(Using a surrounding air temperature of 105˚C for 5000 hours). With these capacitors, the service life of the converter is further extended.

*1 : Surrounding air temperature: Annual average of 40ºC (free from corrosive gas, flammable gas, oil mist, dust and dirt).

The design life is a calculated value and is not a guaranteed product life.

*2 : Input current: 80% of the high power factor converter rating

 Estimated service lifespan of the consumable parts

Part name

Cooling Fan

Estimated lifespan

10 years

Reference value by JEMA * 3

2 to 3 years

Main circuit smoothing capacitor 10 years 5 years

Smoothing capacitors on the printed board 10 years 5 years

*3 : Excerpt from "The Periodic Inspection Recommendations on General-purpose

Inverters" by the Japan Electrical Manufactures Association (JEMA).

(2) The leading-edge life diagnosis function

 The degree of deterioration of the main circuit capacitor, cooling fan, and inrush current limit circuit can be diagnosed on the monitor.

 Using the self-diagnosis function, the part life warning can be output and the deterioration degree can be monitored.

Thus, the self-diagnosis function prevents troubles from occurring.

*4 : A warning is output when any of the control circuit capacitor, inrush current limit circuit, and cooling fan reaches its output level.

Features

6

Operation panel equipped with the setting dial

(FR-DU07-CNV)

 Parameters can be copied using the operation panel

(FR-DU07-CNV).

The setting values of the parameters can be stored to the operation panel and the option parameter unit (FR-PU07).

 Items such as input current, input voltage, input power (with the regenerative display), bus voltage, etc. can be monitored.

 Operation can be easily performed with the setting dial.

Parameter change example

7

Supporting more network protocols

 HC2 supports RS-485 as a standard. With the option

FR-A7NC, HC2 also supports CC-Link.

•The power can be monitored during driving/regenerative driving, and this monitoring tells you the energy saving effect.

•Alarm functions and voltage monitors of each phase help you to spot the cause of the alarm.

FR-HC2 Inverter Inverter

Programmable controller

Terminating resistor

FR-A7NC FR-A8NC

CC-Link dedicated cable

CC-Link network

FR-A8NC

Terminating resistor

Applications

[Ceiling crane]

G

Trolley line

Trolley line

IM

Hoisting motor

IM

Crane

IM G

W

Rail

Power supply

Standard accessories

High power factor converter

(FR-HC2)

Inverter

Traveling motor

Inverter

Inverter

B

B

Traveling motor

Hosting motor

B

• The power regeneration function is installed. A brake

unit is not required.

•The mechanical brake is powered from the power

supply side of the standard accessories.

[Water treatment plant (pump)]

Power supply

Standard accessories

High power factor converter

(FR-HC2)

Inverter

Inverter

• Power supply harmonics of inverters can be

suppressed.

• The power regeneration function is installed.

A brake unit is not required.

Motor

Motor

Protective functions dimension drawings

Option and peripheral

Extensive lineup

Model

F R - H C 2 - 7.5K

High power factor converter basic model name

Capacity (kW)

Three-phase 200V class

Three-phase 400V class

7.5

15

30

Symbol

No sign

H

55

Voltage

200V class

400V class

75

Symbol

7.5K to 560K

Applicable capacity

Represents the capacity kW.

110

160

220

280

400

560

    

 : Available model −: Not available

Compliant with UL, cUL, EC Directives (CE marking), and Radio Waves Act (South Korea, KC marking).

Also, certified as compliant with the Eurasian Conformity (EAC).

The high power factor converters are compliant with the EU RoHS Directive (Restriction of the Use of Certain Hazardous Substances in

Electrical and Electronic Equipment), friendly to people and to the environment.

To obtain higher environmental resistance, the FR-HC2 has coated printed circuit boards and copper plated conductors. Magnetic contactors also have anti-corrosive coatings on.

The coated printed circuit board model (FR-HC K-60) of the conventional series is replaceable with the standard model of this series.

[Note]

• These coating treatments do not guarantee an operation environment beyond the range indicated in the product specification.

• Coating is applied to the printed circuit board areas excluding its LEDs, connectors, terminal blocks and their peripherals, where coating cannot be applied.

• As for the anti-corrosive treatment of the magnetic contactor, plating is applied to the copper areas where no surface treatment is applied.

Standard accessories

Refer to page 9

Precaution on selection and

High power factor converter * 1

(FR-HC2)

Reactor 1

(FR-HCL21)

Reactor 2

(FR-HCL22)

Outside box * 2

(FR-HCB2)

*1 : Use in combination with standard accessories. Cables for connecting standard accessories are not provided.

*2 : Peripheral devices are separately provided for 280K or higher (not provided as the outside box).

5