Parameter list. Mitsubishi Electric FR-HC2-7.5K


Add to my manuals
40 Pages

advertisement

Parameter list. Mitsubishi Electric FR-HC2-7.5K | Manualzz

Parameter list

REMARKS

 indicates simple mode parameters.

The parameters shaded in allow their settings to be changed during operation even if "1" (write disabled) is set to Pr. 77

Parameter write selection .

Parameter

44

45

46

47

48

49

31

32

33

34

27

28

29

30

35

36

23

24

25

26

 14

 15

16

 22

9

10

7

8

11

12

 13

4

5

6

 0

 1

 2

3

 50

 51

 52

 53

 54

 55

 56

 57

Name Range

Simple mode selection

Maximum power supply frequency

Minimum power supply frequency

ROH terminal function selection

SOF terminal function selection

X1 terminal function selection

X2 terminal function selection

RES terminal function selection

SOF input selection

OH input selection

RDY signal logic selection

RSO terminal function selection

CVO terminal function selection

Y1 terminal function selection

0, 9999

60Hz (Read only)

50Hz (Read only)

0 to 5, 9999

0, 1, 2

0, 1

0, 100

Y2 terminal function selection

Y3 terminal function selection

ABC terminal function selection

Current limit level

Current limit level (regenerative)

OL signal output timer

Input current detection level

Input current detection signal delay time

0 to 16, 98, 99, 100 to 116,

198, 199, 9999

0 to 220%

0 to 220%, 9999

0 to 25s, 9999

0 to 220%

0 to 10s

Input current detection signal retention time 0 to 10s, 9999

Input current detection operation selection 0, 1

Zero current detection level

Zero current detection time

0 to 220%

0 to 1s

Life alarm status display

Inrush current limit circuit life display

Control circuit capacitor life display

Maintenance timer

0 to 15 (Read only)

0 to 100% (Read only)

0 to 100% (Read only)

0 (1 to 9998)

Maintenance timer alarm output set time

Cooling fan operation selection

Instantaneous power failure detection signal clear

Power supply frequency monitoring reference

0 to 9998, 9999

0, 1

0, 9999

AM output filter

Watt-hour meter clear

0 to 5s

0, 10, 9999

Energization time carrying-over times Read only

Cumulative power monitor digit shifted times 0 to 4, 9999

45Hz to 65Hz

AM terminal function selection

1 to 3, 5, 6, 7, 21,

1111 to 4444

Input power monitoring reference

DU/PU main display data selection

Input voltage monitoring reference

FM terminal function selection

Bus voltage monitoring reference

Current monitoring reference

Restart selection

0 to 100kW/0 to 3600kW

* 

0, 5 to 10, 25,

1111 to 4444

0 to 500V

1 to 3, 5, 6, 7, 21,

1111 to 4444

0 to 1000V

0 to 500A/0 to 3600A

0, 9999

Increments

1

0.01s

1

1

1

0.01Hz

1

1

1

0.1%

0.1%

0.1s

0.1%

0.1s

0.1s

1

0.1%

0.01s

1

1%

1%

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

Initial value

9999

0.01s

9999

0

9999

60Hz

4

5

99

150%

9999

0s

150%

0s

0.1s

0

5%

0.5s

0

100%

100%

0

9999

1

1

2

3

3

0

0

100

0

60Hz

50Hz

5

0

1

2

Customer setting

1

0.01kW/

0.1kW



1

0.1V

1

0.1V

0.01A/0.1A



1

1234

Rated power

1234

220V/440V



1234

340V/680V



Rated current

9999

23

24

Parameter Name Range Increments Initial value

58

59

61

65

67

68

69

75

120

121

123

124

 145

168

169

269

342

500



 77

80

81

82

83

117

118

119

Free parameter 1

Free parameter 2

Key lock operation selection

Retry selection

Number of retries at fault occurrence

Retry waiting time

Retry count display erase

Reset selection/disconnected PU detection/

PU stop selection

Parameter write selection

Voltage control proportional gain

Voltage control integral gain

Current control proportional gain

Current control integral gain

PU communication station number

PU communication speed

PU communication stop bit length

PU communication parity check

Number of PU communication retries

PU communication waiting time setting

PU communication CR/LF selection

PU display language selection

0 to 9999

0 to 9999

0, 10

0, 1, 2, 3, 4

0 to 10, 101 to 110

0.1 to 360s

0

0 to 3, 14 to 17

1, 2

0 to 1000%

0 to 1000%

0 to 200%

0 to 200%

0 to 31

48, 96, 192, 384

0, 1, 10, 11

0, 1, 2

0 to 10, 9999

0 to 150ms, 9999

0, 1, 2

0 to 7

Parameter for manufacturer setting. Do not set.

501



Communication EEPROM write selection 0, 1

Communication error execution waiting time 0 to 999.8s

Communication error occurrence count display

0

Stop mode selection at communication error 0, 3 502



542

 , 

543

 ,  , 

544



Communication station number (CC-Link)

Baud rate (CC-Link)

CC-Link extended setting

C0(900)



FM terminal calibration

C1(901)



AM terminal calibration

989

990

Parameter copy alarm release

PU buzzer control

991

Pr.CL

ALLC

Er.CL

PCPY

PU contrast adjustment

Parameter clear

All parameter clear

Fault history clear

Parameter copy

1 to 64

0 to 4

0, 1, 12

10, 100

0, 1

0 to 63

0, 1

0, 1

0, 1

0, 1, 2, 3

1

1

1

1

1

1

1

0.1s

1

1

1%

1

1

1

1

1%

1%

1%

1

1

1ms

1

1

1

0.1s

1

1

1

1

1

1

1

1

1

1

 Differ according to capacities. (55K or lower/75K or higher)

 Differs according to the voltage class. (200V class/400V class)

 Parameters which can be set when the plug-in option (FR-A7NC) is mounted.

 The setting is reflected after converter reset or at the next power-ON.

 "L.ERR" LED on FR-A7NC flickers when a setting is changed. If the converter is reset, the setting is reflected and LED turns off.

 The parameter number in parentheses is the one for use with the parameter unit (FR-PU07).

0

0s

0

0

1

0

0

10/100



1

58

0

0

0

0

9999

9999

0

0

0

1s

0

14

2

100%

100%

100%

100%

0

192

1

2

1

9999

1

0

Customer setting