Parameter list
REMARKS
indicates simple mode parameters.
The parameters shaded in allow their settings to be changed during operation even if "1" (write disabled) is set to Pr. 77
Parameter write selection .
Parameter
44
45
46
47
48
49
31
32
33
34
27
28
29
30
35
36
23
24
25
26
14
15
16
22
9
10
7
8
11
12
13
4
5
6
0
1
2
3
50
51
52
53
54
55
56
57
Name Range
Simple mode selection
Maximum power supply frequency
Minimum power supply frequency
ROH terminal function selection
SOF terminal function selection
X1 terminal function selection
X2 terminal function selection
RES terminal function selection
SOF input selection
OH input selection
RDY signal logic selection
RSO terminal function selection
CVO terminal function selection
Y1 terminal function selection
0, 9999
60Hz (Read only)
50Hz (Read only)
0 to 5, 9999
0, 1, 2
0, 1
0, 100
Y2 terminal function selection
Y3 terminal function selection
ABC terminal function selection
Current limit level
Current limit level (regenerative)
OL signal output timer
Input current detection level
Input current detection signal delay time
0 to 16, 98, 99, 100 to 116,
198, 199, 9999
0 to 220%
0 to 220%, 9999
0 to 25s, 9999
0 to 220%
0 to 10s
Input current detection signal retention time 0 to 10s, 9999
Input current detection operation selection 0, 1
Zero current detection level
Zero current detection time
0 to 220%
0 to 1s
Life alarm status display
Inrush current limit circuit life display
Control circuit capacitor life display
Maintenance timer
0 to 15 (Read only)
0 to 100% (Read only)
0 to 100% (Read only)
0 (1 to 9998)
Maintenance timer alarm output set time
Cooling fan operation selection
Instantaneous power failure detection signal clear
Power supply frequency monitoring reference
0 to 9998, 9999
0, 1
0, 9999
AM output filter
Watt-hour meter clear
0 to 5s
0, 10, 9999
Energization time carrying-over times Read only
Cumulative power monitor digit shifted times 0 to 4, 9999
45Hz to 65Hz
AM terminal function selection
1 to 3, 5, 6, 7, 21,
1111 to 4444
Input power monitoring reference
DU/PU main display data selection
Input voltage monitoring reference
FM terminal function selection
Bus voltage monitoring reference
Current monitoring reference
Restart selection
0 to 100kW/0 to 3600kW
0, 5 to 10, 25,
1111 to 4444
0 to 500V
1 to 3, 5, 6, 7, 21,
1111 to 4444
0 to 1000V
0 to 500A/0 to 3600A
*
0, 9999
Increments
1
0.01s
1
1
1
0.01Hz
1
1
1
0.1%
0.1%
0.1s
0.1%
0.1s
0.1s
1
0.1%
0.01s
1
1%
1%
1
1
1
1
1
1
1
1
1
1
1
1
1
1
—
—
1
Initial value
9999
0.01s
9999
0
9999
60Hz
4
5
99
150%
9999
0s
150%
0s
0.1s
0
5%
0.5s
0
100%
100%
0
9999
1
1
2
3
3
0
0
100
0
60Hz
50Hz
5
0
1
2
Customer setting
1
0.01kW/
0.1kW
1
0.1V
1
0.1V
0.01A/0.1A
1
1234
Rated power
1234
220V/440V
1234
340V/680V
Rated current
9999
23
24
Parameter Name Range Increments Initial value
58
59
61
65
67
68
69
75
120
121
123
124
145
168
169
269
342
500
77
80
81
82
83
117
118
119
Free parameter 1
Free parameter 2
Key lock operation selection
Retry selection
Number of retries at fault occurrence
Retry waiting time
Retry count display erase
Reset selection/disconnected PU detection/
PU stop selection
Parameter write selection
Voltage control proportional gain
Voltage control integral gain
Current control proportional gain
Current control integral gain
PU communication station number
PU communication speed
PU communication stop bit length
PU communication parity check
Number of PU communication retries
PU communication waiting time setting
PU communication CR/LF selection
PU display language selection
0 to 9999
0 to 9999
0, 10
0, 1, 2, 3, 4
0 to 10, 101 to 110
0.1 to 360s
0
0 to 3, 14 to 17
1, 2
0 to 1000%
0 to 1000%
0 to 200%
0 to 200%
0 to 31
48, 96, 192, 384
0, 1, 10, 11
0, 1, 2
0 to 10, 9999
0 to 150ms, 9999
0, 1, 2
0 to 7
Parameter for manufacturer setting. Do not set.
501
Communication EEPROM write selection 0, 1
Communication error execution waiting time 0 to 999.8s
Communication error occurrence count display
0
Stop mode selection at communication error 0, 3 502
542
543
544
Communication station number (CC-Link)
Baud rate (CC-Link)
CC-Link extended setting
C0(900)
FM terminal calibration
C1(901)
AM terminal calibration
989
990
Parameter copy alarm release
PU buzzer control
991
Pr.CL
ALLC
Er.CL
PCPY
PU contrast adjustment
Parameter clear
All parameter clear
Fault history clear
Parameter copy
1 to 64
0 to 4
0, 1, 12
—
—
10, 100
0, 1
0 to 63
0, 1
0, 1
0, 1
0, 1, 2, 3
—
—
1
1
1
1
1
1
1
0.1s
1
1
1%
1
1
1
1
1%
1%
1%
1
1
1ms
1
1
1
0.1s
1
1
1
1
1
1
1
1
1
1
Differ according to capacities. (55K or lower/75K or higher)
Differs according to the voltage class. (200V class/400V class)
Parameters which can be set when the plug-in option (FR-A7NC) is mounted.
The setting is reflected after converter reset or at the next power-ON.
"L.ERR" LED on FR-A7NC flickers when a setting is changed. If the converter is reset, the setting is reflected and LED turns off.
The parameter number in parentheses is the one for use with the parameter unit (FR-PU07).
0
0s
0
0
1
0
0
—
—
10/100
1
58
0
0
0
0
9999
9999
0
0
0
1s
0
14
2
100%
100%
100%
100%
0
192
1
2
1
9999
1
0
Customer setting
advertisement
Related manuals
advertisement
Table of contents
- 1 FR-HC2 catalog
- 4 Features
- 6 Connection example
- 7 Standard specifications
- 7 Standard specification rating
- 8 Common specifications
- 9 Checking peripheral devices
- 10 Selection of the high power factor converter and the inverter
- 11 Inverter parameter settings
- 12 Wiring of several inverters to one converter
- 13 Outline dimension drawings
- 17 Protruding the heatsink
- 19 Terminal connection diagram (when using with the FR-A800 series)
- 21 Terminal specification explanation
- 23 Parameter list
- 25 Protective functions
- 26 Option and peripheral devices
- 26 Option List
- 26 Peripheral devices/cable size list
- 30 Precaution on selection and operation
- 30 Installation Precautions
- 30 Wiring distance
- 30 Reactor installation at power supply side
- 30 Operating Precautions
- 30 Selection Precautions
- 30 Connectable inverter
- 30 Sine wave filter selection precautions
- 31 Peripheral Device Selection Precautions
- 31 Selection and installation of the moulded case circuit breaker
- 31 Electromagnetic interference
- 33 Warranty