GENERATOR START-UP PROCEDURE (AUTO MODE)
STARTING (AUTO MODE)
DANGER
Before connecting this generator to any building’s electrical system, a licensed
electrician must install an isolation
(transfer) switch. Serious damage to the building’s electrical system may occur without this transfer switch.
When starting generator in AUTO mode use the “Manual
Start-up” procedure except where noted (see below).
1. Perform steps 1 through 5 in the Before Starting section as outlined in the Manual Starting Procedure.
2. Place the engine speed switch (Figure 51) in the
HIGH position
CAUTION
When connecting the generator to a isolation (transfer) switch, ALWAYS have power applied to the generator’s internal battery charger. This will ensure that the engine will not fail due to a dead battery.
NOTICE
When the generator is set in the AUTO mode, the generator will automatically start in the event of commercial power falling below a prescribed level by means of a contact closure that is generated automatically by a transfer switch.
Figure 51. Engine Speed Switch (High)
3. Place the MPEC Control Switch (Figure 52) in the
AUTO position.
Figure 52. MPEC Control Switch (AUTO)
4. Continue operating the generator as outlined in the
Manual Start-up procedure (start at step 5).
WARNING
When running the generator in the AUTO mode, remember the generator can start up at any time without warning. NEVER attempt to perform any maintenance when the generator is in the auto mode.
CAUTION
The engine speed switch must be set to the “High” position when running in the auto-start mode. Failing to set the switch in the proper position can result in damage to your generator when it turns on.
NOTICE
When the MPEC control switch is placed in the AUTO position, the engine glow plugs will be warmed and the engine will start automatically.
PAGE 36 — DCA400SSI GENERATOR • OPERATION AND PARTS MANUAL — REV. #2 (11/03/08)
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 Proposition 65 Warning
- 3 Reporting Safety Defects
- 4 Table Of Contents
- 5 Parts Ordering Procedures
- 6 Safety Information
- 12 Specifi cations
- 13 Dimensions
- 14 Installation
- 16 General Information
- 17 Major Components
- 18 Generator Control Panel
- 20 Engine Operating Panel
- 22 Output Terminal Panel Familiarization
- 25 Load Application
- 26 Generator Outputs
- 27 Gauge Reading
- 28 Output Terminal Panel Connections
- 30 Inspection/Setup
- 34 Generator Start-Up Procedure (Manual)
- 36 Generator Start-Up Procedure (Auto Mode)
- 37 Generator Shut-Down Procedures
- 38 Maintenance
- 42 Trailer Maintenance
- 46 Trailer Wiring Diagram
- 47 Generator Wiring Diagram
- 48 Engine Wiring Diagram
- 49 Controller Wiring Diagram
- 50 Troubleshooting (Generator)
- 51 Troubleshooting (Engine Controller)
- 52 Troubleshooting (Diagnostic Lamp)
- 54 Explanation Of Code In Remarks Column
- 55 Suggested Spare Parts
- 56 Generator Assembly
- 60 Engine Operating Panel Assembly
- 62 Control Box Assembly
- 68 Engine And Radiator Assembly
- 72 Output Terminal Assembly
- 74 Battery Assembly
- 78 Fuel Tank Assembly (S/N 3813334 & Below)
- 80 Fuel Tank Assembly (S/N 3813335 & Above)
- 82 Enclosure #1 Assembly
- 84 Enclosure #2 Assembly
- 86 Enclosure #3 Assembly
- 90 Rubber Seals Assembly
- 92 Nameplate And Decals Assembly
- 96 Terms And Conditions Of Sale — Parts