Function of indicators

Figure 3

Power Button

This button is used to Switch ON & OFF the water purifier.

• When there is a leak in the water purifier, the power button starts to blink with continuous beep till it is fixed.

• When the water pressure is lower than required water pressure limits, the power button starts to blink continuously with the beep sound for 10 seconds till the water pressure becomes normal.

Note: Call A. O. Smith Customer care centre, if you notice continuous blinking of Power light.

Tank full indicator

This indicates that the water purifier tank is full.

• When there is an overflow the indicator starts to blink with continuous beep till it is fixed.

Note: Call A. O. Smith Customer care centre, if you notice continuous blinking of Tank full indicator.

07

Auto flush indicator

This indicates flushing is in progress. Everytime the water purifier is switched ON the auto flushing cleans the RO membrane. It enhances the life of RO membrane.

Note: Call A. O. Smith Customer care centre, if you notice continuous blinking of Auto flush indicator.

RO change indicator

This indicates that the RO membrane and/or PAC filter needs to be replaced.

• RO change indicator glows when 10% life is remaining, indicating that it is time to replace RO membrane and/or PAC filter.

• When RO membrane and/or PAC life reaches its end, this indicator will start to blink continuously. The unit will not function until RO membrane and/or PAC filter is replaced.

• When the system is switched ON every time, the buzzer beeps for 10 times and the unit will not function until RO membrane and/or PAC filter is replaced.

Note: Call A. O. Smith Customer care centre, to replace the RO membrane and/or PAC filter.

Sediment & Carbon (SC) change indicator

This indicates that the Sediment filter and/or Carbon Block filter needs to be replaced.

• SC change indicator glows when 10% life is remaining, indicating that it is time to change Sediment filter and/or Carbon Block filter.

• When Sediment filter and/or Carbon Block filter life reaches its end, this indicator will start to blink continuously and the unit will not function until Sediment filter and/or

Carbon Block filter is replaced.

• When the system is switched ON every time, the buzzer beeps for 10 times and the unit will not function until Sediment filter and/or Carbon Block filter is replaced.

Note: Call A. O. Smith Customer care centre, to replace the Sediment filter and/or Carbon Block filter.