7. Installation of Decorative Panel
The decorative panel has its installation direction.
Before installing the decorative panel, always remove the paper template.
1. Temporarily fix two decorative panel fixing screws (hexagon M5 screw) on the unit body. (Tighten by amount
10mm in length.)
The fixing screws (hexagon M5 screw) are included the indoor unit box.
2. Remove the air inlet grille from the decorative panel. (Remove the hook for the air inlet grille cord.)
3. Hook the decorative panel key hole ( ) on the screws fixed in step above, and slide the panel so that the screws reach the key hole edge.
4. Retighten completely two temporarily fixed screws and other two screws. (Total 4 screws)
5. Connect the louver motor connector and display connector.
6. After tightening these screws, install the air inlet grille (including the air filter).
Air conditioner unit
Piping side
Decorative panel fixing screws
(hexagon M5 screws)
Temporally fitting at 2 places
(Tightening about 10mm)
Decorative panel
Key holes
Decorative panel fixing screws
(Hexagon M5 screw)
Control box cover
Display
Lead wire for louver motor and display
12
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 3 1.The following should be always observed for safety
- 4 2.Installation of Indoor, Outdoor Unit
- 4 1) Selection of the best location
- 5 bolt location(unit: mm)
- 6 3) The Indoor Unit Installation
- 6 4) Remote Controller Installation
- 8 5) Wiring Connection
- 9 ELECTRICAL WIRING
- 9 CONNECTING THE CABLE TO OUTDOOR UNIT
- 10 6) Connecting Pipes to the Indoor Unit
- 11 PIPING CONNECTION
- 12 7) Installation of Decorative Panel
- 13 8) Indoor Unit Drain Piping
- 14 HEAT INSULATION
- 14 FORM THE PIPINGS
- 15 3. Test running
- 15 1) PRECAUTIONS IN TEST RUN
- 15 INSTALLATION IS COMPLETE
- 16 2) Connection of power supply
- 16 3) Evaluation of the performance
- 17 4. Auxiliary operation
- 17 1) Two thermistor system
- 18 2) Ajusting to the height of ceiling
- 19 3) Group control (optional wiring)
- 20 4) Central control (optional)