advertisement
A check valve is included with the SDM-E2. It is intended for use on the exhaust fitting when manifolding multiple docking stations together. See “Assembling a
Manifold for Multiple SDM-E2 Units” on page 12 for manifolding instructions.
Figure 5: Check Valve
Instrument Panel
The instrument panel is located on the top of the SDM-E2 and includes the instrument cradle, the exhaust bellow, the IR port, the charging cord, and a recess for the fitting at the end of the gas out to EAGLE 2 line. The instrument cradle is a recessed area on the top of the SDM-E2 that is designed to accept the EAGLE 2.
Insert the EAGLE 2 in the instrument cradle before you perform a bump test, calibrate, or charge an EAGLE 2. The exhaust bellow is at the back of the instrument panel and must line up with the exhaust port on the EAGLE 2 when it is in the cradle.
The instrument panel also has a protective metal loop to protect the exhaust bellow and to prevent the EAGLE 2 from being accidentally dislodged from the cradle.
Follow the instructions in this manual and at the center of the instrument cradle for installing the EAGLE 2 in the cradle to avoid damaging the exhaust bellow. An infrared (IR) port at the rear of the panel lines up with the EAGLE 2’s IR port when it is inserted in the cradle and is used to communicate with the EAGLE 2. The charging cord and the fitting at the end of the gas out to EAGLE 2 line are stored in the instrument panel.
7 • Description
Figure 6: Instrument Panel
advertisement
Related manuals
advertisement
Table of contents
- 6 Introduction
- 7 System Requirements
- 8 Specifications
- 9 About This Manual
- 9 Cautions & Safety Information
- 10 Description
- 10 AC Adapter
- 10 Single-Port AC Adapter
- 10 3-Port AC Adapter
- 11 USB Cable
- 11 Air Filter, Sample Tubing, and Check Valve
- 12 Instrument Panel
- 13 Back Panel
- 13 Power Jack
- 13 Sample Fittings
- 13 PC Connection
- 14 Control Panel
- 15 Front Panel
- 16 Hardware Setup
- 16 Hardware Assembly
- 17 Assembling a Manifold for Multiple SDM-E2 Units
- 18 Exhaust Tubing
- 20 GAS 1 Tubing
- 20 GAS 2 Tubing
- 24 Connecting Calibration Gas
- 26 EAGLE 2 and GX Type Instrument Connection
- 26 Installing the SDM-E2 Docking Station PC Controller Program
- 32 Launching the SDM-E2 Docking Station PC Controller Program
- 33 Overview of the SDM-E2 Docking Station PC Controller Program
- 33 PC Controller Program Functions
- 34 Main Program Window
- 34 Control Buttons
- 34 SDM-E2/EAGLE 2 Display Area
- 35 Program Status
- 35 Fitting Indicators
- 35 Setting Up the PC Controller Program
- 35 Setting Up the Configuration
- 40 Setting Up the SDM-E2 Display Order
- 42 Cylinders Window
- 43 Selecting a Cylinder from the Pre-Defined List
- 44 Defining New Cylinders
- 45 Connecting Instruments to the PC Controller Program
- 49 Icon View vs. Details View
- 51 Exporting an Instrument List from the Main Program Window
- 52 Instrument Placement for Bump Testing and Calibration
- 54 Automatic Bump Testing and Calibration
- 55 Bump Testing a Standard 4-Gas Instrument
- 66 Calibrating a Standard 4-Gas Instrument
- 76 Bump Testing an Instrument with Special Sensors
- 92 Calibrating and Instrument with Special Sensors
- 107 Troubleshooting
- 108 Charging an Instrument in an SDM-E
- 108 Recharging a Battery Pack After Performing a Bump Test or Calibration
- 109 Recharging a Battery Pack Without Performing any Operations
- 110 Batteries Too Drained for PC Controller Operation
- 111 Logs Button
- 115 Alarm Trend Data
- 123 Calibration Data
- 125 Event Data
- 127 Interval Trend Data
- 137 Memo Data
- 139 Bump Test Data
- 143 Deleting Data in the Logs Window
- 144 Instrument Function Menu
- 144 Open Function
- 145 Edit Function
- 145 Parameter Tab
- 152 Sensor Tab
- 153 Station & User Tab
- 159 Conversion Table Tab
- 163 PID Sensor Tab
- 169 Channel Gas Tab
- 170 Gas Name Tab
- 170 Download Function
- 170 Clear Logs Function
- 171 Power Off Function
- 171 Obtaining a Relative Response Factor
- 182 Config Window
- 182 Parameter Tab
- 183 Database Tab
- 185 Password Tab
- 186 Spare Parts List
- 190 Appendix A: Multiple Instrument Configurations
- 190 Bump Testing Multiple EAGLE 2s with Different Sensor Configurations
- 207 Calibrating Multiple EAGLE 2s with Different Sensor Configurations
- 223 Appendix B: Bump Testing and Calibrating EAGLE 2s with IR Sensors