INSTALLATION INSTRUCTIONS. Blaze King APEX CBT


Add to my manuals
40 Pages

advertisement

INSTALLATION INSTRUCTIONS. Blaze King APEX CBT | Manualzz

APEX CBT

INSTALLATION INSTRUCTIONS

GENERAL

INSTALLATION IS TO BE PERFORMED BY A QUALIFIED INSTALLER

Please take time to read these instructions thoroughly. Not following the instructions could result in a faulty installation causing serious problems. Along with these general instructions you must follow the specifi c instructions which pertain to your particular installation i.e.: add-on to electric, gas, oil or independent installations.

FREIGHT DAMAGE

its arrival. If damage is found report it to the carrier and then immediately fi le a freight damage claim. Blaze King will not be held responsible for damage incurred once the product leaves our factories.

PARTS INCLUDED WITH THE APEX CBT

1. 2 Fan limit controls and bracket

3. Rake

5. Insulation strips (3 pieces)

6. Digital Combustor thermometer

OPTIONAL EQUIPMENT

1. Blower and cabinet for independent use (900 cfm. to 1200 cfm.), see “VB1000 BLOWER” on page 24.

2. 24 volt control transformer

USAGE

1. An add-on to any of the following furnaces:

A. An electric forced air furnace rated at 15 KW to 27 KW with a minimum size fan of 900

cfm. (see “INSTALLATION INSTRUCTIONS - Combination APEX-Electric” on page 19)

B. A forced air gas furnace with a maximum output of 120,000 btu. and a minimum size fan

of 900 cfm. (see “INSTALLATION INSTRUCTIONS - Combination APEX-Gas/Oil” on page

21)

C. An oil furnace having an oil input as shown on the nameplate of not more than 1.2 usgph.

and a fan capacity of not less than 900 cfm. (see “INSTALLATION INSTRUCTIONS -

Combination APEX-Gas/Oil” on page 21)

2. As an independent forced air wood furnace equipped with a blower of not less than 900

cfm. Capacity (see “INSTALLATION INSTRUCTIONS - Wood only” on page 23).

Page 9

OM-APEX E V1.06

November 19, 2012

Page 10

APEX CBT

INSTALLATION INSTRUCTIONS cont.

CAUTIONS

properly sized and fi tted according to the installation codes. Upstream of the supply connection, the fi tter shall provide a manual shut-off valve.

1. All installations must comply with local building safety codes.

2. Installation shall be by a licensed, qualifi ed installer experienced in heating equipment installations.

3. THE WOOD SECTION MUST BE VENTED INTO A CHIMNEY APPROVED FOR SOLID FUEL

USE IN GOOD CONDITION. MOST GAS FURNACES ARE VENTED INTO “B” VENTS, THIS

IS UNACCEPTABLE FOR SOLID FUEL APPLIANCES. THE APEX CBT MUST NOT BE

VENTED INTO ANY TYPE OF CHIMNEY THAT ALSO SERVES ANOTHER APPLIANCE.

4. DO NOT CONNECT THE DUCT WORK SO REVERSE OR PARALLEL FLOW IS POSSIBLE.

5. DO NOT RELOCATE ANY OF THE CONTROLS ON THE ORIGINAL OR ALTERNATE

FURNACE.

6. Ensure that all existing or alternate furnace systems are in good operating condition before installing the add-on. Always maintain required clearances from the existing or alternate furnace.

Blaze King supports the WETT ( Wood Energy Technology Transfer Inc, Canada) & NFI (National Fireplace and maintenance of wood heating systems.

CLEARANCES TO COMBUSTIBLES

WOOD CHARGING END (DOOR) 48 in. (1220 mm)

ONE SIDE (A) 6 in. (150 mm)

OTHER SIDE

BACK (B)

18 in. (460 mm)

3.5 in. (90 mm)

PLENUM & FIRST 2 FT (0.6 M) OF DUCT

FLUE (D*)

FLUE (C)

1 in. (25 mm)

10* in. (250 mm)

18 in. (460 mm) IN CANADA

*check with local codes, 18” may be required for single wall pipe*

Fig. 1a

If the furnace sits on a combustible fl oor, a non-combustible shield must be used underneath the furnace and extending 18 in. out from the charging end and 8 in. on either side of the fuel-loading door. A non-combustible shield is also required underneath the chimney connector and extending at least 2 in. on either side of the chimney connector. (minimum size fl oor protector= 65” x 31.5”)

It is not required to be a heat protective covering.

This furnace must be installed in compliance with all local codes and regulations.

OM-APEX E V1.06

November 19, 2012

APEX CBT

INSTALLATION INSTRUCTIONS cont.

Page 11

Fig. 1b

Can be as little as 6” but 8” is recommended for easier access to the bypass handle

FURNACE LOCATION

installation. Ceiling height of the furnace room needs to be a minimum of

6’ 6”(1.98 M). Hot air Plenum and Duct work can only run Horizontally or Up, NEVER down.

12 in. x 17 in. typical installations see fi g. 3.

alternate furnace is located. Cut the opening max. 1 1/2 inches from the fl oor and locate close to the front, about

Note the bypass handle is located on the left side of the Apex, but can be moved to the right side, this might be required in some installations to clear return air plenum or counter fl ow on existing or alternate furnace. See

“INSTALLATION INSTRUCTIONS cont.” on page 14 for instructions.

OM-APEX E V1.06

November 19, 2012

Page 12

HOT AIR TO HOUSE

ALTERNATE

HOT AIR

PLENUM

GAS, OIL

ELECTIRC

UP FLOW

FURNACE

CBT

HOT AIR TO HOUSE

RETURN

AIR

PLENUM

COUNTER/

FLOW GAS

ELECTRIC

OR OIL

CBT

35 KIT

WARNING:

Hot air Plenum and

Duct work can only

LAYOUT

NEVER down.

Fig. 3 Typical installation illustration

INSTALLATION INSTRUCTIONS cont.

APEX CBT

HOT AIR TO HOUSE

ALTERNATE

HOT AIR

PLENUM

GAS, OIL

ELECTRIC

UP FLOW

FURNACE

EXISTING

CBT

HOT AIR SUPPLY

PLENUM

RETURN

AIR

COUNTER/

FLOW GAS

ELECTRIC

IT

PLENUM

ED

OR OIL

PR

WOOD COUNTERFLOW

INSTALLATION REQUIRES

CF6 KIT OPTION

NOTE

IN THIS CONFIGURATION

SPECIAL CLEARANCES APPLY

SEE CF6KIT INSTRUCTIONS.

DO NOT INSTALL IN THIS

CONFIGURATION WITHOUT

OM-APEX E V1.06

November 19, 2012

APEX CBT

Page 13

INSTALLATION INSTRUCTIONS cont.

Apex CBT as independent furnace:

When the blower is installed on the left side of the Apex CBT, the bypass handle needs to be moved to the right

side (see “INSTALLATION INSTRUCTIONS cont.” on page 14), so if possible, install the blower on the right

side.

Install the blower more to the front of the unit as that is where most of the heat is. When using the VB1000 blower cut an opening 13 1/4” W x 11 13/16” H in the side panel about 9” from the front (Distance A, see fi g. opening that way. Use the pre-punched cutouts if applicable.

W

H

Casing

A

Fig. 4

Metal strip

Fig. 5

Insulation

DO NOT USE INTERCONNECT DUCT ELBOWS THAT HAVE AN INSIDE RADIUS OF LESS THAN

6” (150mm.). THE WARM-AIR SUPPLY OF THE APEX FURNACE SHALL NOT BE CONNECTED

TO THE COLD-AIR RETURN INLET OF THE EXISTING OR ALTERNATE FURNACE. THE

POSSIBILITY EXISTS THAT THE COMPONENTS OF THE EXISTING OR ALTERNATE FURNACE

MAY OVERHEAT, CAUSING THE CENTRAL FURNACE TO OPERATE OTHER THAN INTENDED.

COMBUSTION AIR

Insure adequate combustion air allowing for all other exhausting type appliances in the dwelling (range hoods, dryers, etc). In airtight houses it is recommended to install a fresh air inlet into the basement room where the furnace is located. Recommended intake size is 1.5 sq in

2 per 1000 BTU’s.

OM-APEX E V1.06

November 19, 2012

Page 14

APEX CBT

INSTALLATION INSTRUCTIONS cont.

MOVE BYPASS HANDLE SYSTEM FROM LEFT TO RIGHT SIDE FURNACE

In some installations it is necessary to move the bypass handle system from the left (default) to the right side of the right makes place for the bypass handle but need to be installed on the left aft er the change-over). Make sure to adjust the handle position and latch so proper seal is achieved on bypass door. Reroute wiring. Fig. 7 shows the correct mounting of the handle latches when moved to right side.

Fig. 6

Fig. 7

PRESSURE LOSS

Before any changes are made to the existing furnace system you must establish the working parameters of that system. You can then insure that addition of the add-on has not degraded the operation of the original system, and correct air fl ow will be maintained. Change all fi lters in the system to insure maximum free air fl ow. Using an accurate manometer check the static pressure at the end of a typical duct near the exit to the house. Check the static pressure in the plenum above the existing furnace also.

Pressure drop = Static pressure at furnace -(minus) static pressure at duct exit

Record the pressure drop of the original system.

Addition of the add-on furnace will add airfl ow resistance in the system. Aft er installation is complete measure the pressure drop in the same run measured before add-on installation. If the air fl ow has diminished the blower speed should be adjusted to compensate. When using a belted blower the pulley size should be changed or adjusted to speed up the blower. If the pulley size is adjusted measure the blower motor current to insure that it is still within the motor plate specifi cation. It may be necessary to replace the motor with a more powerful motor. If a direct drive blower is used change to a higher motor speed. Do not change the blower size.

OM-APEX E V1.06

November 19, 2012