APEX CBT

Page 19

INSTALLATION INSTRUCTIONS - Combination APEX-Electric

ADD-ON TO ELECTRIC FURNACE

Minimum blower capacity must be at least 900 cfm. Electric furnaces approved for installation in any position can be inverted and used in a down fl ow position using an adapter duct between the furnace and the addto combustibles must be maintained. Refer to general and pressure loss portions of this manual also (see

“INSTALLATION INSTRUCTIONS cont.” on page 14) .

If changes are made to the installation of the electric furnace they must comply with CSA Standard C22.1.

AN INTERLOCK LIMIT SWITCH MUST BE INCLUDED IN THE CONTROL CIRCUITRY

PREVENTING THE GAS FURNACE FROM OPERATING WHEN THE SYSTEM OUTPUT PLENUM

TEMPERATURE IS ABOVE 150°F. TYPICAL WIRING DIAGRAM FOLLOWS: SEE FIG 21. IF

YOUR ELECTRIC FURNACE DOES NOT HAVE AN R AND G CONNECTION SEE FIG. 22.

OM-APEX E V1.06

November 19, 2012

Page 20

APEX CBT

INSTALLATION INSTRUCTIONS - Combination APEX-Electric

Fig. 21 ELECTRICAL CONNECTIONS WOOD/ELECTRIC WITH R AND G CONNECTIONS

OM-APEX E V1.06

November 19, 2012