TC1200 REFERENCE MANUAL

Keyboard Intercode Delay

This parameter specifies the intercode delay between the end of one code and the beginning of the next. The delay can be set within a range of zero (0) to 99 seconds in 1 second increments. A setting of zero specifies no delay.

To set the delay:

1. Determine the desired setting in seconds. (0-99).

2. Use the Chart in

Appendix C

to find the hex equivalent for the desired numeric value.

3. Go to and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter

Programming Mode.

4. Scan the barcode: SELECT INTERCODE DELAY.

5. Scan the two hex equivalent characters from the keypad in

Appendix B

that represent the numeric value determined in step 1 above.

NOTE

If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit.

This completes the procedure.

5.2 READING PARAMETERS

Illumination Mode

Selects the illumination mode for the reader. The illumination mode can be used to:

 to increase the overall diode life

 to reduce power consumption;

 to turn off the illuminator for safety purposes.

Selections:

Disabled: the illuminator is always off.

Enabled: the illuminator is always on.

Triggered: the illuminator is turned on when the reading phase starts. The illuminator is turned off as soon as the code(s) are read or when the reading phase ends.

The Triggered selection is ignored for Automatic and Test Operating

Modes.

118