advertisement
B
B KEYPAD
0
ÌÄ0:Î
2
ÌÄ2>Î
4
ÌÄ4BÎ
6
ÌÄ6FÎ
8
ÌÄ8JÎ
A
ÌÄA\Î
142
TC1200 REFERENCE MANUAL
1
ÌÄ1<Î
3
ÌÄ3@Î
5
ÌÄ5DÎ
7
ÌÄ7HÎ
9
ÌÄ9LÎ
B
ÌÄB^Î
KEYPAD
C
ÌÄC`Î
E
ÌÄEdÎ
CANCEL
ÌÄ~oÎ
D
ÌÄDbÎ
F
ÌÄFfÎ
B
143
C
TC1200 REFERENCE MANUAL
Char Hex Dec
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
SUB
ESC
FS
GS
RS
US
SPACE
!
&
'
(
)
"
#
$
%
BS
HT
LF
VT
FF
CR
SO
SI
DLE
DC1
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
00 0
01 1
02 2
03 3
04 4
05 5
06 6
07 7
08 8
09 9
0A 10
0B 11
0C 12
0D 13
0E 14
0F 15
10 16
11 17
12 18
13 19
14 20
15 21
16 22
17 23
18 24
19 25
1A 26
1B 27
1C 28
1D 29
1E 30
1F 31
20 32
21 33
22 34
23 35
24 36
25 37
26 38
27 39
28 40
29 41
Char Hex Dec Char Hex Dec
H
I
J
K
D
E
F
G
@
A
B
C
<
=
>
?
P
Q
R
S
T
L
M
N
O
6
7
8
9
:
;
2
3
4
5
0
1
.
/
*
+
,
- s t u v o p q r k l m n i j g h w x y z
{
|
}
~
DEL a b c d e f
]
^
_
`
Y
Z
[
\
U
V
W
X
2A 42
2B 43
2C 44
2D 45
2E 46
2F 47
30 48
31 49
32 50
33 51
34 52
35 53
36 54
37 55
38 56
39 57
3A 58
3B 59
3C 60
3D 61
3E 62
3F 63
40 64
41 65
42 66
43 67
44 68
45 69
46 70
47 71
48 72
49 73
4A 74
4B 75
4C 76
4D 77
4E 78
4F 79
50 80
51 81
52 82
53 83
54 84
55 85
56 86
57 87
58 88
59 89
5A 90
5B 91
5C 92
5D 93
5E 94
5F 95
60 96
61 97
62 98
63 99
64 100
65 101
66 102
67 103
68 104
69 105
6A 106
6B 107
6C 108
6D 109
6E 110
6F 111
70 112
71 113
72 114
73 115
74 116
75 117
76 118
77 119
78 120
79 121
7A 122
7B 123
7C 124
7D 125
7E 126
7F 127
144
ASCII CHART
Char Hex Dec
80 128
81 129
82 130
83 131
84 132
85 133
86 134
87 135
88 136
89 137
8A 138
8B 139
8C 140
8D 141
8E 142
8F 143
90 144
91 145
92 146
93 147
94 148
95 149
96 150
97 151
98 152
99 153
9A 154
9B 155
9C 156
9D 157
9E 158
9F 159
A0 160
A1 161
A2 162
A3 163
A4 164
A5 165
A6 166
A7 167
A8 168
A9 169
C
Char Hex Dec Char Hex Dec
AA 170
AB 171
AC 172
AD 173
AE 174
AF 175
B0 176
B1 177
B2 178
B3 179
B4 180
B5 181
B6 182
B7 183
B8 184
B9 185
BA 186
BB 187
BC 188
BD 189
BE 190
BF 191
C0 192
C1 193
C2 194
C3 195
C4 196
C5 197
C6 198
C7 199
C8 200
C9 201
CA 202
CB 203
CC 204
CD 205
CE 206
CF 207
D0 208
D1 209
D2 210
D3 211
D4 212
D5 213
D6 214
D7 215
D8 216
D9 217
DA 218
DB 219
DC 220
DD 221
DE 222
DF 223
E0 224
E1 225
E2 226
E3 227
E4 228
E5 229
E6 230
E7 231
E8 232
E9 233
EA 234
EB 235
EC 236
ED 237
EE 238
EF 239
F0 240
F1 241
F2 242
F3 243
F4 244
F5 245
F6 246
F7 247
F8 248
F9 249
FA 250
FB 251
FC 252
FD 253
FE 254
FF 255
145
D
TC1200 REFERENCE MANUAL
Reserved Characters
[SOH]
[BEL]
#
$
0
3
B
D
E
F
R
S h i s t
[FF]
Reserved Strings
C<up to 36 chars>[CR]
01[CR]
34[CR]
Hex Value Notes
0x01
0x07
0x23
0x24
0x30
0x33
0X42
0X44
0X45
0X46
0X52
0X53
0x68
0x69
0x73
0x74
0xFF
0x43 <xxx> 0x0D C can be used without [CR] or inside a string (not the first character)
0x30 0x31 0x0D
0x33 0x34 0x0D
146
DECLARATION OF CONFORMITY
EC-126
Rev.: 1
Pag.: 1 di 1
Datalogic Automation S.r.l.
Via Lavino 265
40050 Monte San Pietro
Bologna - Italy www.automation.datalogic.com
declares that the and all its models
TC1200; Compact CCD Reader
are in conformity with the requirements of the European Council Directives listed below:
2004 / 108 / EC EMC Directive
______________________________________________
This Declaration is based upon compliance of the products to the following standards:
EN 55022 ( C
LASS
A ITE ), S
EPTEMBER
1998:
INFORMATION TECHNOLOGY EQUIPMENT
RADIO DISTURBANCE CHARACTERISTICS
L
IMITS AND METHODS OF MEASUREMENTS
EN 61000-6-2, S
EPTEMBER
2005:
E
LECTROMAGNETIC COMPATIBILITY
(EMC)
P
ART
6-2: G
ENERIC STANDARDS
I
MMUNITY FOR INDUSTRIAL
ENVIRONMENTS
Monte San Pietro, July 20th, 2010
Lorenzo Girotti
Product & Process Quality Manager
UNI EN ISO 14001
www.automation.datalogic.com
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 13 INTRODUCTION
- 13 Configuration Methods
- 13 Configuration Using Datalogic Aladdin
- 13 Configuration Using Serial Programming Strings
- 13 Configuration Using Programming Barcode Labels
- 14 BUTTON AND LED Indicators
- 14 Available Models
- 15 INSTALLATION
- 15 TC1200 CCD Scanner
- 15 Mechanical Installation
- 16 Electrical Connections
- 20 TC1200 CCD Scan Engine
- 20 Mechanical Installation
- 21 Electrical Connections
- 25 Positioning
- 26 SOFTWARE CONFIGURATION STRINGS
- 26 TC1200 Configuration
- 43 BARCODE CONFIGURATION
- 43 Initial Setup
- 43 Restore Default
- 43 Interface Selection
- 45 Changing Default Settings
- 46 Global Interface Features
- 48 Baud Rate
- 48 Parity
- 49 Data Bits
- 49 Stop Bits
- 50 RS232/USB-COM
- 51 Intercharacter Delay
- 51 Disable Character
- 51 Enable Character
- 51 ACK/NAK Options
- 51 ACK Character
- 52 NAK Character
- 52 ACK/NAK Timeout
- 52 ACK/NAK Retry Count
- 52 ACK/NAK Error Handling
- 53 USB-KBD
- 54 Keyboard Country
- 55 Keyboard Country (continued)
- 55 Keyboard Intercode Delay
- 56 Send Control Characters
- 56 USB Keyboard Speed
- 57 USB Keyboard Speed (continued)
- 58 READING PARAMETERS
- 59 Illumination Mode
- 59 Operating Mode
- 59 Automatic Threshold
- 60 Phase Off Event
- 60 Timeout
- 60 Serial Start
- 60 Serial Stop
- 60 LED Indication
- 61 Label Programming Mode
- 62 DATA FORMAT
- 63 Data Transmission
- 63 Code Verifier Mode
- 63 Match String
- 63 Wrong Code String
- 64 Case Conversion
- 64 Global Prefix
- 64 Global Suffix
- 64 No Read String
- 65 Transmit AIM IDs
- 65 Transmit Custom Label IDs
- 65 Custom Label Identifiers
- 66 Custom Label Identifiers (continued)
- 68 Custom Code Identifiers (continued)
- 69 DIGITAL OUTPUTS
- 70 Output 1 Activation Event
- 70 Output 1 Deactivation Event
- 70 Output 1 Deactivation Timeout
- 70 Output 1 Activation Event
- 71 Output 2 Activation Event
- 71 Output 2 Deactivation Event
- 71 Output 2 Deactivation Timeout
- 71 Output 2 Activation Event
- 72 POWER SAVE
- 73 Sleep Mode Timeout
- 74 CODE SELECTION
- 75 UPC-A
- 75 Check Character Tx
- 75 Expand to EAN
- 75 Number System Tx
- 76 UPC-A Minimum Reads
- 76 Coupon Control
- 77 UPC-E
- 77 Check Character Tx
- 77 Expand to UPC-A
- 77 Expand to EAN
- 78 Number System Tx
- 78 UPC-E Minimum Reads
- 79 Check Character Tx
- 79 ISBN Conversion
- 79 ISSN Conversion
- 80 Flag 1 Character
- 80 EAN-13 Minimum Reads
- 80 Coupon Control
- 81 Check Character Tx
- 81 Expand to EAN
- 81 EAN-8 Minimum Reads
- 82 Enable Optional P2 Add-On
- 82 Enable Optional P5 Add-On
- 82 P2 Minimum Reads
- 83 P5 Minimum Reads
- 83 Optional Add-On Timer
- 84 GTIN Format
- 84 Decoding Level
- 84 Character Correlation
- 85 In-Store Minimum Reads
- 85 Code 39 Full ASCII
- 85 Code Length Control
- 86 Set Length
- 86 Code 39 Check Tx
- 86 Code 39 Start/Stop Tx
- 87 Code 32 (Italian Pharmaceutical)
- 87 Code 32 Check Tx
- 87 Code 32 Start/Stop Tx
- 88 Check Calculation
- 88 Minimum Reads
- 89 Decoding Level
- 89 Character Correlation
- 89 Interdigit Ratio
- 90 Quiet Zones
- 90 Stitching
- 91 GS1-128 Enable
- 91 Code Length Control
- 91 Set Length
- 92 Expand to Code
- 92 Check Tx
- 92 Function Character Tx
- 92 Sub-Code Change Tx
- 93 Minimum Reads
- 93 Decoding Level
- 94 Character Correlation
- 94 Quiet Zones
- 94 Stitching
- 95 ISBT 128 Concatenation
- 95 Concatenation Mode
- 95 Dynamic Concatenation Timeout
- 96 Interleaved 2 of
- 96 Code Length Control
- 96 Set Length
- 97 Check Calculation
- 97 Check Tx
- 98 Minimum Reads
- 98 Decoding Level
- 99 Character Correlation
- 99 Stitching
- 99 Zero Pattern
- 100 Standard 2 of
- 100 Code Length Control
- 100 Set Length
- 100 Check Calculation
- 101 Check Tx
- 101 Minimum Reads
- 102 Decoding Level
- 102 Character Correlation
- 102 Stitching
- 103 Codabar
- 103 Code Length Control
- 103 Set Length
- 104 Codabar ABC
- 104 Concatenation Mode
- 104 Dynamic Concatenation Timeout
- 105 Check Calculation
- 105 Check Tx
- 105 Start/Stop Set
- 106 Start/Stop Tx
- 106 Start/Stop Match
- 106 Minimum Reads
- 107 Decoding Level
- 107 Character Correlation
- 107 Interdigit Ratio
- 108 Quiet Zones
- 108 Stitching
- 109 Code Length Control
- 109 Set Length
- 110 Check Calculation
- 110 Check Tx
- 111 Minimum Reads
- 111 Decoding Level
- 112 Character Correlation
- 112 Interdigit Ratio
- 112 Stitching
- 113 GS1 DataBar Omnidirectional
- 113 GS1 DataBar Omnidirectional GS1-128 Emulation
- 113 Minimum Reads
- 114 GS1 DataBar Expanded
- 114 GS1 DataBar Expanded GS1-128 Emulation
- 114 Code Length Control
- 114 Set Length
- 115 Minimum Reads
- 115 Coupon Control
- 116 GS1 DataBar Limited
- 116 GS1 DataBar Limited GS1-128 Emulation
- 116 Minimum Reads
- 117 Code Length Control
- 117 Set Length
- 118 Check Calculation
- 118 Check Tx
- 119 Minimum Reads
- 119 Decoding Level
- 120 Character Correlation
- 120 Quiet Zones
- 120 Stitching
- 121 Code Length Control
- 121 Set Length
- 122 Check Calculation
- 122 Check Tx
- 123 Minimum Reads
- 123 Decoding Level
- 124 Stitching
- 125 PARAMETER REFERENCES
- 125 RS232 Parameters
- 125 RS232 Only
- 126 RS232/USB COM Parameters
- 130 Reading Parameters
- 130 Illumination Mode
- 131 Operating Mode
- 134 Good Read LED
- 135 Data Formatting
- 136 Global Prefix/Suffix
- 138 Code Identifiers
- 141 Code Verifier
- 142 Digital Outputs
- 143 Power Save
- 143 Code Selection
- 145 Concatenation
- 146 Set Length
- 148 TECHNICAL FEATURES
- 149 Reading Diagrams
- 150 DEFAULT PARAMETERS TABLE
- 154 KEYPAD