5.5 POWER SAVE
Sleep Mode Timeout
Specifies the timeout value for the reader to enter low power Sleep Mode.
This is available only in On Line operating mode.
The reader wakes up when receiving an input signal or trigger button press. The reader cannot connect to Aladdin when in power save mode. It must first receive a wake up from the input signal or trigger button press.
5.6 CODE SELECTION
EAN-UPC Optional Add-On Timer
This option sets the time the reader will look for an add-on when an add-on fragment has been seen and optional add-ons are enabled.
To set this value:
1. Determine the desired setting in milliseconds (x 10 ms). (1-30).
2. Use the Chart in
to find the hex equivalent for the desired numeric value.
3. Go to and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter
Programming Mode.
4. Scan the barcode: SET ADD-ON TIMER VALUE.
5. Scan the two hex equivalent characters from the keypad in
that represent the numeric value determined in step 1 above.
NOTE
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure.
Decoding Level
Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs.
Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
Level 5 results in a very aggressive decoder. This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors.
Level 3, which is the default setting, allows the majority of product labels to be decoded.
131
5
TC1200 REFERENCE MANUAL
There are many factors that determine when to change the decoding level for a particular symbology. These factors include spots, voids, non-uniform bar/space widths, damaged labels, etc. that may be experienced in some barcode labels. If there are many hard to read or damaged labels that cannot be decoded using a conservative setting, increase the decoding level to be more aggressive. If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level.
Minimum Reads
This feature specifies the minimum number of consecutive times a label must be decoded before it is accepted as good read.
Interdigit Ratio
This feature specifies the ratio between an intercharacter space and module for given symbology labels.
To set this value:
1. Determine the desired ratio setting. (1-10).
2. Use the Chart in
to find the hex equivalent for the desired numeric value.
3. Go to relative Code Symbology page and scan the ENTER/EXIT PROGRAMMING
MODE barcode to enter Programming Mode.
4. Scan the barcode: SET INTERDIGIT RATIO.
5. Scan the two hex equivalent characters from the keypad in
that represent the numeric value determined in step 1 above.
NOTE
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure.
Character Correlation
When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
132
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 13 INTRODUCTION
- 13 Configuration Methods
- 13 Configuration Using Datalogic Aladdin
- 13 Configuration Using Serial Programming Strings
- 13 Configuration Using Programming Barcode Labels
- 14 BUTTON AND LED Indicators
- 14 Available Models
- 15 INSTALLATION
- 15 TC1200 CCD Scanner
- 15 Mechanical Installation
- 16 Electrical Connections
- 20 TC1200 CCD Scan Engine
- 20 Mechanical Installation
- 21 Electrical Connections
- 25 Positioning
- 26 SOFTWARE CONFIGURATION STRINGS
- 26 TC1200 Configuration
- 43 BARCODE CONFIGURATION
- 43 Initial Setup
- 43 Restore Default
- 43 Interface Selection
- 45 Changing Default Settings
- 46 Global Interface Features
- 48 Baud Rate
- 48 Parity
- 49 Data Bits
- 49 Stop Bits
- 50 RS232/USB-COM
- 51 Intercharacter Delay
- 51 Disable Character
- 51 Enable Character
- 51 ACK/NAK Options
- 51 ACK Character
- 52 NAK Character
- 52 ACK/NAK Timeout
- 52 ACK/NAK Retry Count
- 52 ACK/NAK Error Handling
- 53 USB-KBD
- 54 Keyboard Country
- 55 Keyboard Country (continued)
- 55 Keyboard Intercode Delay
- 56 Send Control Characters
- 56 USB Keyboard Speed
- 57 USB Keyboard Speed (continued)
- 58 READING PARAMETERS
- 59 Illumination Mode
- 59 Operating Mode
- 59 Automatic Threshold
- 60 Phase Off Event
- 60 Timeout
- 60 Serial Start
- 60 Serial Stop
- 60 LED Indication
- 61 Label Programming Mode
- 62 DATA FORMAT
- 63 Data Transmission
- 63 Code Verifier Mode
- 63 Match String
- 63 Wrong Code String
- 64 Case Conversion
- 64 Global Prefix
- 64 Global Suffix
- 64 No Read String
- 65 Transmit AIM IDs
- 65 Transmit Custom Label IDs
- 65 Custom Label Identifiers
- 66 Custom Label Identifiers (continued)
- 68 Custom Code Identifiers (continued)
- 69 DIGITAL OUTPUTS
- 70 Output 1 Activation Event
- 70 Output 1 Deactivation Event
- 70 Output 1 Deactivation Timeout
- 70 Output 1 Activation Event
- 71 Output 2 Activation Event
- 71 Output 2 Deactivation Event
- 71 Output 2 Deactivation Timeout
- 71 Output 2 Activation Event
- 72 POWER SAVE
- 73 Sleep Mode Timeout
- 74 CODE SELECTION
- 75 UPC-A
- 75 Check Character Tx
- 75 Expand to EAN
- 75 Number System Tx
- 76 UPC-A Minimum Reads
- 76 Coupon Control
- 77 UPC-E
- 77 Check Character Tx
- 77 Expand to UPC-A
- 77 Expand to EAN
- 78 Number System Tx
- 78 UPC-E Minimum Reads
- 79 Check Character Tx
- 79 ISBN Conversion
- 79 ISSN Conversion
- 80 Flag 1 Character
- 80 EAN-13 Minimum Reads
- 80 Coupon Control
- 81 Check Character Tx
- 81 Expand to EAN
- 81 EAN-8 Minimum Reads
- 82 Enable Optional P2 Add-On
- 82 Enable Optional P5 Add-On
- 82 P2 Minimum Reads
- 83 P5 Minimum Reads
- 83 Optional Add-On Timer
- 84 GTIN Format
- 84 Decoding Level
- 84 Character Correlation
- 85 In-Store Minimum Reads
- 85 Code 39 Full ASCII
- 85 Code Length Control
- 86 Set Length
- 86 Code 39 Check Tx
- 86 Code 39 Start/Stop Tx
- 87 Code 32 (Italian Pharmaceutical)
- 87 Code 32 Check Tx
- 87 Code 32 Start/Stop Tx
- 88 Check Calculation
- 88 Minimum Reads
- 89 Decoding Level
- 89 Character Correlation
- 89 Interdigit Ratio
- 90 Quiet Zones
- 90 Stitching
- 91 GS1-128 Enable
- 91 Code Length Control
- 91 Set Length
- 92 Expand to Code
- 92 Check Tx
- 92 Function Character Tx
- 92 Sub-Code Change Tx
- 93 Minimum Reads
- 93 Decoding Level
- 94 Character Correlation
- 94 Quiet Zones
- 94 Stitching
- 95 ISBT 128 Concatenation
- 95 Concatenation Mode
- 95 Dynamic Concatenation Timeout
- 96 Interleaved 2 of
- 96 Code Length Control
- 96 Set Length
- 97 Check Calculation
- 97 Check Tx
- 98 Minimum Reads
- 98 Decoding Level
- 99 Character Correlation
- 99 Stitching
- 99 Zero Pattern
- 100 Standard 2 of
- 100 Code Length Control
- 100 Set Length
- 100 Check Calculation
- 101 Check Tx
- 101 Minimum Reads
- 102 Decoding Level
- 102 Character Correlation
- 102 Stitching
- 103 Codabar
- 103 Code Length Control
- 103 Set Length
- 104 Codabar ABC
- 104 Concatenation Mode
- 104 Dynamic Concatenation Timeout
- 105 Check Calculation
- 105 Check Tx
- 105 Start/Stop Set
- 106 Start/Stop Tx
- 106 Start/Stop Match
- 106 Minimum Reads
- 107 Decoding Level
- 107 Character Correlation
- 107 Interdigit Ratio
- 108 Quiet Zones
- 108 Stitching
- 109 Code Length Control
- 109 Set Length
- 110 Check Calculation
- 110 Check Tx
- 111 Minimum Reads
- 111 Decoding Level
- 112 Character Correlation
- 112 Interdigit Ratio
- 112 Stitching
- 113 GS1 DataBar Omnidirectional
- 113 GS1 DataBar Omnidirectional GS1-128 Emulation
- 113 Minimum Reads
- 114 GS1 DataBar Expanded
- 114 GS1 DataBar Expanded GS1-128 Emulation
- 114 Code Length Control
- 114 Set Length
- 115 Minimum Reads
- 115 Coupon Control
- 116 GS1 DataBar Limited
- 116 GS1 DataBar Limited GS1-128 Emulation
- 116 Minimum Reads
- 117 Code Length Control
- 117 Set Length
- 118 Check Calculation
- 118 Check Tx
- 119 Minimum Reads
- 119 Decoding Level
- 120 Character Correlation
- 120 Quiet Zones
- 120 Stitching
- 121 Code Length Control
- 121 Set Length
- 122 Check Calculation
- 122 Check Tx
- 123 Minimum Reads
- 123 Decoding Level
- 124 Stitching
- 125 PARAMETER REFERENCES
- 125 RS232 Parameters
- 125 RS232 Only
- 126 RS232/USB COM Parameters
- 130 Reading Parameters
- 130 Illumination Mode
- 131 Operating Mode
- 134 Good Read LED
- 135 Data Formatting
- 136 Global Prefix/Suffix
- 138 Code Identifiers
- 141 Code Verifier
- 142 Digital Outputs
- 143 Power Save
- 143 Code Selection
- 145 Concatenation
- 146 Set Length
- 148 TECHNICAL FEATURES
- 149 Reading Diagrams
- 150 DEFAULT PARAMETERS TABLE
- 154 KEYPAD