Trane XB80 Furnace Performance Data
Add to My manuals16 Pages
The XB 80 Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace is a single-stage fan assisted combustion system that features an integrated system control for ease of service, a hot surface igniter for quiet and efficient operation, and a 4-speed, direct drive blower motor for sufficient airflow.
advertisement
TDD-D-1
Upflow/Horizontal Right or
Upflow/Horizontal Left
Induced Draft Gas Furnace
XB 80
TUE1A040A9241A, TUE1A060A9241A, TUE1A060A9361A
TUE1B060A9361A, TUE1B080A9361A, TUE1B080A9481A
TUE1B100A9361A, TUE1C100A9481A, TUE1C100A9601A
TUE1D120A9601A, TUE1D140A9601A
Single-Stage Fan Assisted
Combustion System
PUB. NO. 22-1666-07
General
Features
NATURAL GAS MODELS
Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National
Standards Institute standards.
SAFE OPERATION
The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety.
QUICK HEATING
Durable, cycle tested, heavy gauge
aluminized steel heat exchanger
quickly transfers heat to provide warm conditioned air to the structure.
BURNERS
Multiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas.
INTEGRATED SYSTEM CONTROL
Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connection points for E.A.C./humidifier.
AIR DELIVERY
The 4-speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed.
STYLING
Heavy gauge steel and “wrap-around”
cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass.
Alternate bottom, left or right side return air connection provision capability.
FEATURES AND
GENERAL OPERATION
The XB 80 High Efficiency Gas Furnaces employs an Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat.
Complete front service access.
a. Low energy power venter b. Vent proving pressure switch.
© Trane 2009
2
Pub. No. 22-1666-07
Pub. No. 22-1666-07
Contents
Feature Summary
Features and Benefits
Standard Equipment
Optional Equipment
General Data
TUE1A040A9241A
TUE1A060A9241A
TUE1A060A9361A
TUE1B060A9361A
TUE1B080A9361A
TUE1B080A9481A
TUE1B100A9361A
TUE1C100A9481A
TUE1C100A9601A
TUE1D120A9601A
TUE1D140A9601A
Performance Data
Electrical Data
Field Wiring
Dimensions
2
4
6
9
11
14
17
3
Features and Benefits
XB 80 STANDARD EQUIPMENT
• Convertible to horizontal left or right
• Power supply 115/1/60
• Single speed venter
• Hot surface igniter
• Integrated system control
• Attractive color accents
• Heavy gauge aluminized steel heat exchanger
• Direct drive 4-speed motor
• Blower door safety switch
• Multiport In-shot burners
• Complete front service access
• Alternate bottom/left/right return air in vertical position
• Slide out blower assembly
• Common vent capability
• Heavy gauge reinforced wrap-around steel cabinet
• Super quiet performance
• Optional L.P. conversion kit
• Left/right gas connection
4
Pub. No. 22-1666-07
Features and Benefits
ACCESSORIES FOR XB 80
OPTIONAL EQUIPMENT (Check mark [
✓
For Comfort Controls, See price book pages ............................................................................................................................... [ ]
CleanEffects
TM
Whole House Air Cleaner (14-1/2" Wide, Upflow / Side Return Furnace) ............................. TFD145ALFR000A [ ]
CleanEffects
TM
Whole House Air Cleaner (17-1/2" Wide, Upflow / Side Return Furnace) ............................. TFD175ALFR000A [ ]
CleanEffects
TM
Whole House Air Cleaner (21" Wide, Upflow / Side Return Furnace) ................................... TFD210ALFR000A [ ]
CleanEffects
TM
Whole House Air Cleaner (24-1/2" Wide, Upflow / Side Return Furnace) ............................. TFD245ALFR000A [ ]
CleanEffects
TM
Whole House Air Cleaner (14-1/2" Wide, Downflow Furnace) ............................................. TFD14DALFR000A [ ]
CleanEffects
TM
Whole House Air Cleaner (17-1/2" Wide, Downflow Furnace) ............................................. TFD17DALFR000A [ ]
CleanEffects
TM
Whole House Air Cleaner (21" Wide, Downflow Furnace) ................................................... TFD21DALFR000A [ ]
CleanEffects
TM
Whole House Air Cleaner (24-1/2" Wide, Downflow Furnace) ............................................. TFD24DALFR000A [ ]
Electronic Air Filter, “Perfect Fit” Super Efficiency (14-1/2" Wide Gas Furnace) ..................................................... TFE145A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Super Efficiency (17-1/2" Wide Gas Furnace) ..................................................... TFE175A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Super Efficiency (21" Wide Gas Furnace) ........................................................... TFE210A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Super Efficiency (24-1/2" Wide Gas Furnace) ..................................................... TFE245A9FR0 [ ]
Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) ....................................................................... TFM145A9FR0 [ ]
Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) ....................................................................... TFM175A9FR0 [ ]
Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) .............................................................................. TFM210A9FR0 [ ]
Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) ....................................................................... TFM245A9FR0 [ ]
Air Filter, “Perfect Fit” Standard Efficiency (14-1/2" Wide Gas Furnace) ................................................................ TFP145A9FR0 [ ]
Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ................................................................ TFP175A9FR0 [ ]
Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) ...................................................................... TFP210A9FR0 [ ]
Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) ................................................................ TFP245A9FR0 [ ]
Coil Enclosure (14-1/2" Wide Cabinets) ........................................................................................................ BAYCLE14A1422A [ ]
Coil Enclosure (17-1/2" Wide Cabinets) ........................................................................................................ BAYCLE17A1722A [ ]
Coil Enclosure (21" Wide Cabinets) .............................................................................................................. BAYCLE21A2130A [ ]
Coil Enclosure (24-1/2" Wide Cabinets) ........................................................................................................ BAYCLE24A2430A [ ]
High Altitude Switch ............................................................................................................................................... BAYHALT248 [ ]
Downflow Subbase ................................................................................................................................................ BAYBASE205 [ ]
Propane Conversion Kit ....................................................................................................................................... BAYLPKT210B [ ]
Propane Conversion Kit (With Stainless Steel burners) ....................................................................................... BAYLPSS210B [ ]
Masonry Chimney Vent Kit ................................................................................................................................... BAYVENT800B [ ]
Filter Accessory Kit Upflow (14.5" & 17.5" Wide Cabiniets) ..................................................................................... BAYFLTR317 [ ]
Filter Accessory Kit Upflow (21" Wide Cabiniets) .................................................................................................... BAYFLTR321 [ ]
Filter Accessory Kit Upflow (24.5" Wide Cabiniets) .................................................................................................. BAYFLTR324 [ ]
5
Pub. No. 22-1666-07
General
Data
PRODUCT SPECIFICATIONS 1
MODEL
TYPE
RATINGS 2
Input BTUH
Capacity BTUH (ICS) 3
AFUE (ICS)
Temp. rise (Min.-Max.) °F.
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGER
Type-Fired
-Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz 4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs)
TUE1A040A9241A
Upflow / Horizontal
40,000
31,000
80.0
30 - 60
Direct
10 x 6
1
4
See Fan Performance Table
1/5
1080
115/1/60
Centrifugal
Direct - 1
1/50 - 3180
115/1/60
1.09
No
High Velocity
1 - 16x25 - 1in.
4 Round
Alum. Steel
-
20
2 — 45
2 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
2
115/1/60
5.4
15
1/2
H x W x D
41-3/4 x 16-1/2 x 30-1/2
119 / 110
TUE1A060A9241A
Upflow / Horizontal
60,000
47,000
80.0
35 - 65
Direct
10 x 6
1
4
See Fan Performance Table
1/5
1080
115/1/60
Centrifugal
Direct - 1
1/50 - 3180
115/1/60
1.09
No
High Velocity
1 - 17x25 - 1in.
4 Round
Alum. Steel
20
3 — 45
3 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
3
115/1/60
5.4
15
1/2
H x W x D
41-3/4 x 16-1/2 x 30-1/2
124 / 115
TUE1A060A9361A
Upflow / Horizontal
60,000
47,000
80.0
30 - 60
Direct
10 x 6
1
4
See Fan Performance Table
1/3
1075
115/1/60
Centrifugal
Direct - 1
1/50 - 3180
115/1/60
1.09
No
High Velocity
1 - 16x25 - 1in.
4 Round
Alum. Steel
20
3 — 45
3 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
3
115/1/60
9.0
15
1/2
H x W x D
41-3/4 x 16-1/2 x 30-1/2
127 / 118
TUE1B060A9361A
Upflow / Horizontal
60,000
47,000
80.0
30 - 60
Direct
10 x 7
1
4
See Fan Performance Table
1/3
1075
115/1/60
Centrifugal
Direct - 1
1/50 - 3180
115/1/60
1.09
No
High Velocity
1 - 16x25 - 1in.
4 Round
Alum. Steel
20
3 — 45
3 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
3
115/1/60
9.0
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
137 / 127
1 Central Furnace heating designs are certified by AGA and CSA.
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
6
Pub. No. 22-1666-07
General
Data
PRODUCT SPECIFICATIONS 1
MODEL
TYPE
RATINGS 2
Input BTUH
Capacity BTUH (ICS) 3
AFUE (ICS)
Temp. rise (Min.-Max.) °F.
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGER
Type-Fired
-Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz 4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs)
TUE1B080A9361A
Upflow / Horizontal
80,000
63,000
80.0
30 - 60
Direct
10 x 7
1
4
See Fan Performance Table
1/3
1075
115/1/60
Centrifugal
Direct - 1
1/50 - 3180
115/1/60
1.09
No
High Velocity
1 - 17x25 - 1in.
4 Round
Alum. Steel
20
4 — 45
4 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
4
115/1/60
9.0
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
142 / 132
TUE1B080A9481A
Upflow / Horizontal
80,000
64,000
80.0
30 - 60
Direct
10 x 8
1
4
See Fan Performance Table
1/3
1075
115/1/60
Centrifugal
Direct - 1
1/50 - 3180
115/1/60
1.09
No
High Velocity
1 - 17x25 - 1in.
4 Round
Alum. Steel
20
4 — 45
4 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
4
115/1/60
9.8
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
142 / 132
TUE1B100A9361A
Upflow / Horizontal
100,000
79,000
80.0
40 - 70
Direct
10 x 7
1
4
See Fan Performance Table
1/3
1075
115/1/60
Centrifugal
Direct - 1
1/50 - 3180
115/1/60
1.09
No
High Velocity
1 - 17x25 - 1in.
4 Round
Alum. Steel
20
5 — 45
5 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
5
115/1/60
9.0
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
151 / 141
TUE1C100A9481A
Upflow / Horizontal
100,000
79,000
80.0
35 - 65
Direct
10 x 8
1
4
See Fan Performance Table
1/2
1075
115/1/60
Centrifugal
Direct - 1
1/50 - 3180
115/1/60
1.09
No
High Velocity
1 - 20x25 - 1in.
4 Round
Alum. Steel
20
5 — 45
5 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
5
115/1/60
11.6
15
1/2
H x W x D
41-3/4 x 23 x 30-1/2
162 / 151
1 Central Furnace heating designs are certified by AGA and CSA.
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
7
Pub. No. 22-1666-07
General
Data
MODEL
TYPE
RATINGS 2
Input BTUH
Capacity BTUH (ICS) 3
AFUE (ICS)
Temp. rise (Min.-Max.) °F.
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGER
Type-Fired
-Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz 4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs)
PRODUCT SPECIFICATIONS 1
TUE1C100A9601A
Upflow / Horizontal
100,000
79,000
80.0
30 - 60
Direct
11 x 10
1
4
See Fan Performance Table
1/2
1075
115/1/60
Centrifugal
Direct - 1
1/50 - 3180
115/1/60
1.09
No
High Velocity
1 - 20x25 - 1in.
4 Round
Alum. Steel
20
5 — 45
5 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
5
115/1/60
13.4
15
1/2
H x W x D
41-3/4 x 23 x 30-1/2
162 / 151
TUE1D120A9601A
Upflow / Horizontal
120,000
96,000
80.0
30 - 60
Direct
11 x 10
1
4
See Fan Performance Table
1/2
1075
115/1/60
Centrifugal
Direct - 1
1/50 - 3180
115/1/60
1.09
No
High Velocity
1 - 24x25 - 1in.
4 Round
Alum. Steel
20
6 — 45
6 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
6
115/1/60
13.4
20
1/2
H x W x D
41-3/4 x 26-1/2 x 30-1/2
186 / 174
TUE1D140A9601A
Upflow / Horizontal
140,000
111,000
80.0
40 - 70
DIRECT
11 x 10
1
4
See Fan Performance Table
3/4
1075
115/1/60
Centrifugal
Direct - 1
1/50 - 3180
115/1/60
1.09
No
High Velocity
1 - 24x25 - 1in.
4 Round
Alum. Steel
20
7 — 45
7 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
7
115/1/60
13.8
20
1/2
H x W x D
41-3/4 x 26-1/2 x 30-1/2
193 / 181
1 Central Furnace heating designs are certified by AGA and CSA.
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
8
Pub. No. 22-1666-07
Performance
Data
MODEL
FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (IN. W.C.)
TUE1A040A9241A
TUE1A060A9241A
TUE1A060A9361A
TUE1B060A9361A
TUE1B080A9361A
TUE1B100A9361A
TUE1B080A9481A
TUE1C100A9481A
TUE1C100A9601A
TUE1D120A9601A
TUE1D140A9601A
1796
1329
1091
780
1799
1598
1402
1210
2104
1868
1597
1395
1517
1299
1093
904
1364
1198
1047
895
1441
1252
1058
890
2066
1856
1617
1407
2351
2096
1736
1442
982
809
678
575
973
800
683
573
1345
1197
1027
895
1821
1325
1090
783
1846
1635
1421
1215
2143
1888
1609
1419
1554
1318
1090
901
1384
1209
1052
903
1464
1257
1046
887
2101
1881
1632
1415
2407
2112
1746
1446
1004
832
701
599
997
821
702
596
1389
1225
1039
903
1839
1323
1092
788
1880
1662
1428
1208
2181
1908
1621
1443
1588
1329
1090
894
1393
1210
1046
900
1476
1249
1020
873
2135
1906
1646
1423
2462
2128
1755
1450
1018
847
716
617
1013
835
712
611
1426
1243
1042
900
SPEED TAP
SPEED TAP
4 HIGH - Black
3 -
2 -
MED.-HIGH - Blue
MED.-LOW - Yellow
1 LOW - Red
4 -
3 -
HIGH - Black
MED.-HIGH - Blue
2 -
1 -
MED.-LOW - Yellow
LOW - Red
4 -
3 -
2 -
1 -
HIGH - Black
MED.-HIGH - Blue
MED.-LOW - Yellow
LOW - Red
4 -
3 -
HIGH - Black
MED.-HIGH - Blue
2 -
1 -
MED.-LOW - Yellow
LOW - Red
4 HIGH - Black
3 -
2 -
MED.-HIGH - Blue
MED.-LOW - Yellow
1 LOW - Red
4 -
3 -
HIGH - Black
MED.-HIGH - Blue
2 -
1 -
MED.-LOW - Yellow
LOW - Red
4 -
3 -
HIGH - Black
MED.-HIGH - Blue
2 -
1 -
MED.-LOW - Yellow
LOW - Red
4 HIGH - Black
3 -
2 -
MED.-HIGH - Blue
MED.-LOW - Yellow
1 LOW - Red
4 -
3 -
HIGH - Black
MED.-HIGH - Blue
2 -
1 -
MED.-LOW - Yellow
LOW - Red
4 -
3 -
2 -
1 -
HIGH - Black
MED.-HIGH - Blue
MED.-LOW - Yellow
LOW - Red
4 -
3 -
HIGH - Black
MED.-HIGH - Blue
2 -
1 -
MED.-LOW - Yellow
LOW - Red
0.10
0.20
0.30
0.40
0.50
0.60
0.70
1756
1319
1083
768
1740
1551
1370
1193
2053
1834
1582
1381
1468
1268
1076
894
1335
1177
1033
888
1408
1234
1050
883
2036
1817
1596
1391
2284
2054
1719
1427
950
779
648
544
941
771
655
543
1298
1160
1005
877
1710
1308
1076
758
1669
1493
1326
1164
2001
1800
1567
1367
1412
1228
1052
881
1296
1147
1008
869
1363
1203
1028
864
2005
1777
1575
1375
2216
2011
1702
1411
910
742
610
507
901
734
617
505
1236
1113
973
848
1641
1275
1059
737
1595
1424
1269
1124
1929
1745
1533
1335
1351
1186
1028
860
1247
1107
973
842
1307
1158
990
834
1923
1724
1535
1338
2143
1949
1656
1383
860
697
585
463
852
689
571
459
1171
1057
931
809
0.80
0.90
1573
1246
1040
719
1489
1345
1199
1073
1856
1690
1498
1302
1278
1135
978
828
1189
1058
928
808
1241
1101
936
794
802
644
512
413
796
636
516
406
1099
991
879
760
763
585
452
357
731
575
452
345
1020
916
817
700
1840
1671
1494
1300
1750
1602
1427
1246
1659
1533
1360
1192
2069
1887
1609
1354
1989
1797
1564
1298
1908
1706
1518
1241
From D330672 Rev. 16
1480
1201
1005
674
1381
1256
1117
1009
1766
1631
1438
1256
1200
1072
917
777
1120
999
873
766
1163
1030
866
742
660
517
384
294
659
506
379
277
934
831
745
629
1392
1165
970
630
1260
1157
1022
935
1676
1572
1377
1209
1102
988
836
638
1042
930
808
717
1074
946
780
680
Pub. No. 22-1666-07
9
Performance
Data
CFM VS. TEMPERATURE RISE
MODEL
CFM (CUBIC FEET PER MINUTE)
500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400
*UE1A040*924** 54 49 42 37 33 30
*UE1A060*924** 63 56 49 44
*UE1A060*936**
*UE1B060*936**
*UE1B080*936**
*UE1B100*936**
56
56
49
49
44
44
59
58
40
40
54
52
37
37
49
49
34
34
46
46
32
32
42
42 40 37 35 33
*UE1B080*948**
*UE1C100*948**
*UE1C100*960**
*UE1D120*960**
*UE1D140*960**
67 62 57 53 49
67 62 57 53 49 46 44 41 39 37
62 57 53 49 46 44 41 39 37 35 34 32 31
59 56 52 49 47 44 42 40
69 65 61 58 55 52 49 47 45
From C340782 Sh.1 Rev.7
10
Pub. No. 22-1666-07
Field
Wiring
WIRING DIAGRAM FOR TUE1 GAS FURNACES
Pub. No. 22-1666-07
11
From Dwg. D342777P01 Rev 01
Field
Wiring
SCHEMATIC DIAGRAMS FOR GAS FURNACES
12
From Dwg. D342777P01 Rev 01
Pub. No. 22-1666-07
Field
Wiring
FIELD WIRING DIAGRAM FOR HEATING ONLY
FIELD WIRING DIAGRAM FOR 1 STAGE FURNACE
1 STAGE HEATING
USING A 1 STAGE HEATING THERMOSTAT
NO COOLING
FURNACE
SEE
NOTE 6
B/C
SEE
NOTE 5
B/C
TO 115 V 1 PH.,
60 HZ., POWER
SUPPLY PER
LOCAL CODES
From drawing B342026 Rv 0
FIELD WIRING DIAGRAM FOR HEATING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER)
FIELD WIRING DIAGRAM FOR 1 STAGE FURNACE
1 STAGE HEATING, 1 STAGE COOLING
USING A 1 STAGE HEATING, 1 STAGE COOLING THERMOSTAT
(OUTDOOR SECTION WITHOUT TRANSFORMER)
FURNACE
OUTDOOR UNIT
(NO TRANSFORMER)
B/C
SEE
NOTE 5
B/C
TO 115 V 1 PH.,
60 HZ., POWER
SUPPLY PER
LOCAL CODES
13
Pub. No. 22-1666-07
From drawing B342023 Rv 0
Dimensions
TUE1 OUTLINE DRAWING
(ALL DIMENSIONS ARE IN INCHES)
MODEL
TUE1A040A9241A
TUE1A060A9241A
TUE1A060A9361A
TUE1B060A9361A
TUE1B080A9361A
TUE1B080A9481A
TUE1B100A9361A
TUE1C100A9481A
TUE1C100A9601A
TUE1D120A9601A
TUE1D140A9601A
A B C
14-1/2" 9-5/8" 13-1/4"
17-1/2" 9-5/8" 16-1/4"
21" 13-1/16" 19-3/4"
24-1/2" 15-5/16" 23-1/4"
D
13"
16"
19-1/2"
23"
From Dwg. 21C340781 Rev. 13
14
Pub. No. 22-1666-07
Notes
Pub. No. 22-1666-07
15
Trane
6200 Troup Highway
Tyler, TX 75707
File No.
Supersedes
PL-UN-FURN-TDD-D-1
TDD-D-1 8/95
3/98 04/09
Since Trane has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice.
advertisement
Key Features
- Single-Stage Fan Assisted Combustion System
- Hot Surface Ignition
- Integrated System Control
- 4-speed blower motor
- Aluminized steel heat exchanger
- Multiport Inshot Burners
Related manuals
Frequently Answers and Questions
What is the type of combustion system used in the XB 80 furnace?
What type of ignition system does the XB 80 furnace use?
What type of blower motor is used in the XB 80 furnace?
What is the purpose of the integrated system control in the XB 80 furnace?
What type of heat exchanger is used in the XB 80 furnace?
What type of burners are used in the XB 80 furnace?
Is the XB 80 furnace convertible to L.P. gas?
advertisement