DETEWE opencom 100 Mounting And Commissioning Manual
જાહેરાત
જાહેરાત
OpenCom
100
OpenCom 105, 107, 110, 120:
Mounting and Commissioning
User Guide
Welcome to DeTeWe
Thank you for choosing this DeTeWe product. Our product meets the strictest requirements with regard to quality and design.
The following instructions will guide you in the operation of your
OpenCom 100 software and answer most of the questions that may arise.
If you require further technical support or information about other De-
TeWe products, please refer to our website at www.detewe.de.
It provides additional notes and tips on the product.
We hope you enjoy using
OpenCom 100.
OpenCom 100 Product
Family
This manual applies to the
OpenCom 100 product family, to which the OpenCom 105,
OpenCom 107, OpenCom 110 and
OpenCom 120 systems belong. If a reference is made in the text to the
OpenCom 100, the description applies to all systems; if the individual characteristics are different, a special note is given.
Besides that, the OpenCom 130/150 and the OpenCom 510 systems also belong to the product family. For these systems separate manuals exist.
We wish you lots of pleasure using your OpenCom 100.
Contents
Features 5
Factory Settings on Delivery 10
OpenCom 107/105 . . . . . . . . . . . . . 10
OpenCom 110 . . . . . . . . . . . . . . . . . 10
OpenCom 120 . . . . . . . . . . . . . . . . . 10
Systems . . . . . . . . . . . . . . . . . . . 11
Installation
15
OpenCom 107 . . . . . . . . . . . . . . . . . 18
OpenCom 105 . . . . . . . . . . . . . . . . . 19
OpenCom 110 . . . . . . . . . . . . . . . . . 20
OpenCom 120 . . . . . . . . . . . . . . . . . 20
Positions of the Ports . . . . . . . . . . . 22
Ports . . . . . . . . . . . . . . . . . . . . . . . 23
Ports . . . . . . . . . . . . . . . . . . . . . . 24
a/b Ports . . . . . . . . . . . . . . . . . . . . . . 24
Actor/Sensor . . . . . . . . . . . . . . . . . . 25
LAN Port . . . . . . . . . . . . . . . . . . . . . . 25
DSL Port. . . . . . . . . . . . . . . . . . . . . . . 25
PCM Port . . . . . . . . . . . . . . . . . . . . . . 26
Sync Port . . . . . . . . . . . . . . . . . . . . . . 26
Basic Setting Switch . . . . . . . . . . . . 26
0
Ports . . . . . . . 28
Ports . . . . . . . . . . . . . . . . . . . . . . 28
a/b Ports . . . . . . . . . . . . . . . . . . . . . . 29
Actor/Sensor Ports . . . . . . . . . . . . . 31
COM Port . . . . . . . . . . . . . . . . . . . . . . 32
LAN Port . . . . . . . . . . . . . . . . . . . . . . 32
Adapter . . . . . . . . . . . . . . . . . . . 33
a/b Adapter . . . . . . . . . . . . . . . . . . . 33
Audio Adapter . . . . . . . . . . . . . . . . . 34
Approved Accessories . . . . . . . 36
Device Combinations . . . . . . . . . . . 37
Connector Module 40
Installation . . . . . . . . . . . . . . . . . . . . 40
Configuration . . . . . . . . . . . . . . . . . . 42
Safety Precautions . . . . . . . . . . . . . 43
Technical Data . . . . . . . . . . . . . . . . . 43
Pinning of RJ 45 Jacks . . . . . . . . . . 44
Switches on Front Panel. . . . . . . . . 44
Scope of Delivery. . . . . . . . . . . . . . . 44
Configuration 45
First Configuration via Serial Port 46
1
2
Configuration under Windows 48
Connection on Serial Port (V.24) . . 49
Serial Port . . . . . . . . . . . . . . . . . . 50
(LAN) . . . . . . . . . . . . . . . . . . . . . . 51
Port . . . . . . . 52
Testing the Setup . . . . . . . . . . . . . . . 52
Starting the Browser . . . . . . . . . . . . 52
Configuration for Linux and MacOS 53
Linux . . . . . . . . . . . . . . . . . . . . . . . . . . 53
MacOS. . . . . . . . . . . . . . . . . . . . . . . . . 53
Configuring the OpenCom 100 54
Preparing the Configuration . . . . . 54
Starting the Web Console. . . . . . . . 54
Loading the Online Help . . . . . . . . . 56
Finishing the Configuration . . . . . . 57
Preconfiguration. . . . . . . . . . . . . . . . 57
Remote Configuration. . . . . . . . . . . 57
Codes for IP Configuration . . . . . . . 58
Configuration. . . . . . . . . . . . . . . 59
Loading SW Updates . . . . . . . . . . . . 59
Resetting the System Data . . . . . . . 60
Hardware Basic Settings Switch . . 60
Generating Your Own MoH Files . . 61
Configuration Examples
62
DNS Name Resolution . . . . . . . . . . . 65
Internet Access . . . . . . . . . . . . . . . . . 65
RAS Access . . . . . . . . . . . . . . . . . . . . . 66
OpenCom 100 in a LAN with an IP-enabled Server 66
DNS Name Resolution . . . . . . . . . . .67
Internet Access . . . . . . . . . . . . . . . . .67
RAS Access . . . . . . . . . . . . . . . . . . . . .68
Costs . . . . . . . . . . . . . . . . . . . . . . . . . .70
Using the Web. . . . . . . . . . . . . . . . . .70
E-mail . . . . . . . . . . . . . . . . . . . . . . . . . 71
NAT . . . . . . . . . . . . . . . . . . . . . . . . . . .71
PBX Networking 73
Functionality of PBX Cascading . . .73
Operation . . . . . . . . . . . . . . . . . . 74
Notes. . . . . . . . . . . . . . . . . . . . . . . . . .75
Connections. . . . . . . . . . . . . . . . . . . . 76
Connection . . . . . . . . . . . . . . . . .78
Configuration . . . . . . . . . . . . . . . . . . 79
Technical Details . . . . . . . . . . . . . . . . 81
Team Functions 84
Explanation of Keys . . . . . . . . . . . . .84
Team Configuration . . . . . . . . . . . . .86
Executive/Secretary Team . . . . . . . 86
Three-member Team . . . . . . . . . . . . 87
Unified Team . . . . . . . . . . . . . . . . . . . 88
Toggle Team . . . . . . . . . . . . . . . . . . .89
Call Queue 91
Activation of Queues . . . . . . . . . . . 92
Call Forwarding . . . . . . . . . . . . . . . . 92
Pickup . . . . . . . . . . . . . . . . . . . . . . . . 92
Hunt Groups . . . . . . . . . . . . . . . . . . . 92
System Telephones . . . . . . . . . 93
Terminals . . . . . . . . . . . . . . . . . . 94
Multi-Company Variant
96
Variant . . . . . . . . . . . . . . . . . . . . 97
Companies . . . . . . . . . . . . . . . . 98
Assigning Users . . . . . . . . . . . . . . . . 98
Assigning Trunk Groups . . . . . . . . . 99
Allocating Routing Codes . . . . . . . 99
Exchange . . . . . . . . . . . . . . . . . . 99
Company Telephone Book. . . . . . 100
Companies . . . . . . . . . . . . . . . 101
Billing Charges per Company . . . 101
Configuring the PC
Software 102
Synchronising the PC Clock 107
Address Queries using LDAP 108
General Information . . . . . . . . . . . 109
Installation and Configuration . . 109
Technical Data for Operation on the OpenCom 100 . . . . . . . . . 110
Configuration Guide 111
Frequently Asked Questions 120
Technical
Specifications 127
Index 129
3
4
Features
The OpenCom 100 communications system is designed to be connected to an ISDN basic access using the
DSS1 protocol. System access (pointto-point) and multi-terminal access
(point-to-multipoint) are both supported. The two forms of access can be configured in parallel.
For this purpose
■ the OpenCom 107/105 has a total of four S
0
ports (one external, one internal and two that are switchable between internal/external),
■ the OpenCom 110 has a total of five S
0
ports (two external, one internal and two switchable between internal/external),
■ the OpenCom 120 has a total of six S
0
ports, all switchable between internal/external.
The firmware of the OpenCom 100 is designed for configuring up to 150 users (300 users on the
OpenCom 120).
You can connect the following devices to the OpenCom 100:
■
Euro-ISDN terminals,
■
DeTeWe system telephones,
■
ISDN telephones (on the U pn port), e.g. the OpenPhone 52,
■
DeTeWe RFP 21 base stations,
■
DECT handsets (in an RFP 21 base station),
■ analogue terminals.
An S
0
port can be used by Euro-ISDN terminals working in accordance with DSS1. A U pn
port is suitable for the OpenPhone range of DeTeWe system telephones and for the De-
TeWe RFP 21 base stations. An analogue port is used by standard analogue devices.
If the CNIP (calling name identification presentation) feature is supported by your network provider, the latter will show you the name of callers in addition to their number for each incoming trunk call. The
OpenCom 100 supports the display of the name on system telephones.
However, if you have created an entry in the telephone book of the
OpenCom 100 under the number of the caller, this will be displayed instead.
The OpenCom 100 can be integrated into an existing network
(LAN) and be used by all workstations as an Internet access router and mail client.
Features
5
6
Configuration and programming of the OpenCom 100 is performed by means of a special Web browser
(known as the “Web console”), which can be run on a connected PC.
The OpenCom 100 can also be configured at the customer service centre and maintained by means of remote configuration.
A PC can be connected via a COM port for the purpose of configuring the system or transferring connection data.
To connect the OpenCom 100 with the existing company hardware, there are two actor ports (output) and one sensor port (input) available. These can be used to operate a door opener and a doorbell via the system, for example (this requires additional equipment).
The OpenCom 100 allows you to use
CTI (computer telephony integration) applications made by other manufacturers. This requires installation of a TAPI driver (supplied on the system CD-ROM) on a Windows
PC. The OpenCom 100 also has an integrated dialling wizard, the
OpenCTI 50, with which users can call up and use telephone functions on PCs without first having to install a special TAPI driver.
The OpenCom 100 complies with the regulations for telecommunications equipment. The DSS1 protocol is implemented.
Packet data in the D channel
Some business applications, for instance POS terminals, cash registers or creditcard terminals, require a permanent data connection over the
X.25 packet data network. Packet data transfer through the ISDN D channel (according to X.31 via SAPI
16) can also be established between several S
0
interfaces of the
OpenCom 100. Simultaneous connections are distinguished by means of a TEI (Terminal Endpoint Identifier).
X.31 packet data can be forwarded between two S
0
interfaces (for instance an internal and external S
0
interface). Equally, data can be forwarded (“routed”) over permanent
QSIG lines. Data can also be routed over an S
2M
interface.
The routing table for X.31 packet data is set in the Configurator under
PBX Configuration: X.31. Additional information can be found in the Configurator online help files.
Internet Access
It is possible to connect individual
PCs to the OpenCom 100 via the internal S
0
ports, or to connect an entire LAN to the OpenCom 100 via the
Ethernet port. These PCs can access the Internet via the OpenCom 100.
For this purpose, several call-by-call providers are preset on the
Features
OpenCom 100 (only national setting
“Germany”). If Internet access is already available from an Internet service provider, this can be configured in the OpenCom 100. If the client network is not IP-capable, the
OpenCom 100 can administer the IP configuration necessary for Internet access. The OpenCom 100 has an integrated DHCP server and a DNS server, which in this case take over IP address administration and name resolution for the client PCs.
The OpenCom 100 enables Internet access for all connected PCs by means of a common IP address. Only this is externally visible. The local IP addresses of the client PCs are translated to the IP address of the
OpenCom 100 by network address translation (NAT). In this way the client PCs in the LAN cannot be reached directly from the Internet.
This protects them from direct external attack. The LAN is additionally protected by the OpenCom 100 filter lists, which can be customised individually (firewall function).
Note: We recommend you to read
through the explanations under Useful Information on Internet Access starting on page 70.
DECT Data Communication
A USB DECT Box or the
OpenPhone 25 DECT terminals enable PCs that are not connected to the
OpenCom 100 via the internal S
0 ports or the Ethernet interface to access the Internet. These PCs can make full use of all the Internet and e-mail features of the OpenCom 100.
Data is transmitted via the internal data interface of the OpenPhone 25, which must be connected to the serial port of the PC by means of the supplied adapter. The Internet can then be accessed directly via the remote data transfer (i.e. dial-up) network. The OpenPhone 25 sets up a data connection with the
OpenCom 100 via the DECT air interface. The remainder of the connection set-up is either direct - through an ISDN B-channel - or indirect - through the internal RAS access of the OpenCom 100. Indirect RAS access is preferable. This uses the routing function of the OpenCom 100 and thus also the security features of the shared Internet access.
Using the USB DECT Box obtainable as an add-on, it is possible for a PC to establish a wireless (DECT) ISDN data connection. This USB DECT Box is connected to the PC via the USB port.
For detailed information on the installation of the required driver software and the various types of con-
figuration, refer to USB DECT Box on
the OpenCom 100 starting on page 109 and to the user guide for
the OpenPhone 25.
For information on configuration of the OpenPhone 25 with a data interface, please refer to the online help
Features
7
8
documentation of the
OpenCom 100.
The OpenCom 100 has an integrated e-mail function that is able to use the POP3, APOP or IMAP4 protocols to check the Internet service provider for incoming mail. A mail account query can be configured for every member of staff
(OpenCom 100 user). The
OpenCom 100 then fetches the incoming e-mail headers (subjects) and senders from the mail server at set intervals, and forwards them to users’ system telephones.
Further Network Features
You can offer staff the possibility of dialling into the LAN by means of
RAS access.
A LAN-to-LAN link can also be implemented by ISDN. In this way two
OpenCom 100s can connect their
LANs by dial-in on demand.
A NET-CAPI program (driver software on the system CD-ROM) allows you to use ISDN functions on those
PCs that do not possess a built-in
ISDN card.
Further Telephony Features
Installing an extra memory card allows you to operate a digital voice memory and voice information system. For more information, refer to the user guides called “OpenVoice” and “OpenAttendant”.
You can optimise your telephone communication by using the team
Features
functions and the call-queuing function.
You can also connect two
OpenCom 100s. This cascading of telecom systems is a simple way to increase the number of terminals that can be connected.
As your company’s requirements grow, the OpenCom 100 can be networked with other telecom systems.
The OpenCom 100 can then operate as a sub-system or DECT server. It is also possible to create a telecom system with several networked telecom installations.
Tip: Refer to the explanations in the glossary (supplied as a PDF file on the system CD-ROM).
Features
9
Factory Settings on Delivery
The following basic settings and features are active on delivery. We recommend that you configure the
OpenCom 100 to your individual requirements before putting it into
operation (see Configuration starting on page 45).
Telephony Functions
OpenCom 107/105
■
The S
0
1 port is configured for multi-terminal access, the S
0
2 port for system access.
■
The S
0
3 and S
0
4 ports are configured as internal S
0
buses with the call numbers 20 and 21.
■
The four U pn
ports are configured for OpenPhone 63 system telephones with the call numbers 30 to 33.
■
The four a/b ports are configured for analogue devices with the call numbers 10 to 13.
OpenCom 110
■
The S
0
1 port is configured for multi-terminal access, the S
0
2 port for system access.
■
The S
0
3, S
0
4 and S
0
5 ports are configured as internal S
0
buses with the call numbers 20 to 22.
■
The eight U pn
ports are configured for OpenPhone 63 system telephones with the call numbers 30 to 37.
■
The four a/b ports are configured for analogue devices with the call numbers 10 to 13.
OpenCom 120
■
The S
0
1 port is configured for multi-terminal access, the S
0
2 port for system access.
■
The S
0
3 to S
0
6 ports are configured as internal S
0
buses with the call numbers 20 to 23.
■
The 18 U pn
ports are configured for OpenPhone 63 system telephones with the call numbers 30 to 47.
10
Telephony Functions Factory Settings on Delivery
■
The four a/b ports are configured for analogue devices with the call numbers 10 to 13.
All OpenCom 100
Communication Systems
■
The OpenCom 100 is configured ready for operation in Germany.
■
Analogue devices: The dialling mode (pulse dialling or DTMF) is automatically detected.
■
All cord-bound terminals connected ring when there are incoming external calls.
■
The system PIN, for example for remote-programmable call diversion, is set at “0000”.
Authorisations
The use of functions by a terminal on the OpenCom 100 is regulated by means of authorisations. These authorisations are configured for user groups to which the users with their terminals are then assigned.
Two user groups are preset: “Administrators” and “Guests”. “Administrators” have access to all functions of the OpenCom 100 and unrestricted configuration rights. Users in the
“Guests” group cannot configure the
OpenCom 100, are not able to make external calls, and have only restricted use of the terminal functions of the OpenCom 100.
Note: When the OpenCom 100 is
commissioned, all connected terminals are initially in the “Administrators” group until a user logs on to the
Web console. Subsequently, all terminals are automatically in the “Guests” group (see also the chapter entitled
Configuring the OpenCom 100 starting on page 54). For more details on
the configuration of user groups, refer to the online help in the chapter entitled “User Manager”.
The following terminal functions are factory preset to the “Administrators” group:
■
External line access: international numbers can be dialled from all configured telephones.
External lines must be seized by entering a prefixed code.
■
Least cost routing is not active.
As soon as LCR is configured, users can make calls via individually selected call-by-call providers.
■
“VIP call” is activated.
Factory Settings on Delivery Authorisations
11
■
Announcements to system telephones are possible.
■
Baby calls can be set up.
■
If a call key is configured for a user on more than one terminal, he can program this key for more than one outgoing call, i.e. he can use his various terminals to make parallel calls from this telephone number.
■
“Pick-up” and “selective pickup” of calls from other telephones are activated. Pick-up protection is deactivated.
■
“Call seizure” is deactivated.
■
The “completion-of-calls to busy subscribers” feature can be activated.
■
If more than one terminal is configured for a user under the same number, he can suppress the signalling of calls on the parallel terminals.
■
The “call queue” function is deactivated.
■
“Reaction: Connection will be disconnected” is deactivated as callers trying to reach a terminal that cannot be reached or is busy will hear a busy signal.
■
Call forwarding to internal or external numbers can be activated.
Call forwarding on no reply is executed after 20 seconds. Doorway calls can be forwarded.
■
It is possible to transfer an external call to an external subscriber.
■
Three-party conferences can be set up.
■
Call protection, call-waiting protection and intercom protection are deactivated.
■
The transmission of one’s own phone number (MSN or system access number) to the display of the external party’s terminal is activated, but can be hidden.
■
The telephone lock can be activated. The terminal PIN is
“0000”.
■
Interception of malicious callers is possible if this feature has been ordered from the network operator.
■
Speed dialling is possible if this has been configured in the
OpenCom 100 central telephone book.
■
The black- and whitelists are not preconfigured and thus not active. If these lists are configured, they can be activated for the user groups. A special list with emergency telephone numbers is preset and activated.
12
Authorisations Factory Settings on Delivery
■
The door opener can be activated from all terminals. Doorway calls can be forwarded.
■
Keypad dialling can be used.
■
Call diversion for SMS calls in the wired network is not activated.
■
The evaluation of connection data by external cost-recording programs is deactivated.
■
The cost multiplier is set to
100%, i.e. the costs are not multiplied by any factor.
■
Every user can change the configuration of the OpenCom 100.
■
Every user can create a personal telephone book and edit entries in the central telephone book.
■
Every user can read out the charges.
■
Every user who has a workplace
PC can use the OpenCTI 50 to make calls, manage calls and messages, dial numbers from both the central and personal telephone books, and use the busy display of the OpenCTI 50.
■
The multi-company variant is not activated.
Internet Functions
Note: Settings for mail and ISP and
RAS access are only possible by acti-
vating the OpenCom 100 IP package
in the Web console’s Configurator in
the SYS Configuration: Licences
■
RAS access (with or without callback) can be set up for every
OpenCom 100 user. RAS access requires activation of the RAS authorisation.
■
More than one mail account query can be set up for every user.
■
Every user with a system terminal can be informed automatically of the receipt of e-mails.
■
Users can disconnect existing Internet connections (via the
OpenCom 100 Web console and from a system terminal if the function has been configured on that terminal).
Factory Settings on Delivery Internet Functions
13
The following IP addresses are preset for the network configuration:
■
Host name: host
■
IP address: 192.168.99.254
■
Network mask: 255.255.255.0
The following addresses are transmitted to the client PCs in the LAN via DHCP or PPP:
■
Gateway address:
192.168.99.254
■
Domain name: domain
■
Domain name server:
192.168.99.254
■
PPP addresses: 192.168.100.0 to
192.168.100.10
■
DHCP addresses: 192.168.99.129 to 192.168.99.148
You can change the IP settings in the
Configurator. Check with the network administrator responsible for the LAN if you wish to do this.
Information Regarding the
Licensing of the IP Package for the OpenCom 100
In order to be able to use the IP package in your communications system, you need an activation key.
You can generate the activation key on the DeTeWe licence server
(http://lizenz.detewe.de).
The activation key is generated on the basis of the serial number of your OpenCom 100 and the transaction record (TAD). The licensing confirmation you received together with your IP package contains all the information you need to carry out this procedure plus your personal TAD.
To generate the activation key for the IP package of the
OpenCom 105, no TAD is required.
The serial number is all you need.
You have therefore not received a separate licence confirmation. Enter the serial number of your
OpenCom 105 in the corresponding field at http://lizenz.detewe.de.
You can read out the serial number on the Web console of the
OpenCom 100 in the Configurator
in the System info: Versions menu.
Please note that the serial number is case sensitive. Leave the field for the
TAD blank.
Note or print out the generated activation key.
Then release the IP package on the
Web console in the Configurator in
the SYS Configuration: Add-ons menu. Additional information can be found in the online help.
14
Internet Functions Factory Settings on Delivery
Installation
Scope of Delivery
The delivery consists of:
■
One OpenCom 100 communications system (OpenCom 107,
OpenCom 105, OpenCom 110 or
OpenCom 120)
■
Two connection cable for the
ISDN S
0
port
■
One V.24 connection cable
■
One adapter cable for connection of RS-232 to RJ45 (for the
COM port of the OpenCom 107/
105)
■
One set of mounting screws and wall plugs
■
A 1.5 m power cable (OpenCom
105, OpenCom 110 or
OpenCom 120 only)
■
One plug-in power supply
(OpenCom 107 only)
■
One OpenPhone 52 quick user guide
■
One OpenPhone 61,63,65 quick user guide
■
One OpenPhone 21, 25 quick user guide
■
One CD
Installation Scope of Delivery
15
Safety Precautions
The CE symbol on the product confirms that it meets the technical guidelines on user safety and electromagnetic compatibility valid at the time of approval.
Please note: Installation and
maintenance should only be performed by specially trained personnel. Always remove the power plug from the mains socket before connecting devices to the OpenCom 100 ports.
CAUTION!
Static charges can damage the
OpenCom 100. Make sure you discharge yourself and your tools before and while installing electrical and electronic components of the OpenCom 100.
DANGER! This device contains hazardous voltages. To make the system dead, remove the power plug from the socket.
The OpenCom 100 may only be plugged into mains sockets with a protective earth conductor. Mount the OpenCom 100 only close to easily accessible sockets.
Only open the housing cover. Unauthorised opening of the module cover and improper repair may damage the OpenCom 100 and could invalidate your warrantee.
Only devices that deliver safety extra-low voltage (SELV) may be connected to the OpenCom 100. Proper use of authorised devices meets this requirement.
Only devices meeting the technical requirements may be connected to the analogue ports. For details, refer
to the section entitled a/b Ports starting on page 24.
Use a shielded Ethernet cable (STP cable, Shielded Twisted Pair cable) to connect the OpenCom 100 to a Local
Area Network (LAN).
Do not allow any fluid to penetrate the OpenCom 100, because this may cause electric shocks or short circuits.
Do not install the OpenCom 100 during a storm. Do not connect or disconnect lines during a storm.
16
Safety Precautions Installation
The OpenCom 100 is designed for indoor use only. Lay the cables so that they cannot be walked on or tripped over.
The connection of external devices to the sensor/actor should be performed by a qualified electrician.
Declarations of Conformity
The OpenCom 107, OpenCom 105,
OpenCom 110 and OpenCom 120 systems conform to the requirements set down in the EU directive
99/5/EC.
The Declaration of Conformity can be viewed at the DeTeWe Web site at http://www.detewe.de.
Mounting Location
The ambient temperature for operating the OpenCom 100 must be between +5 and +40°C. The power supply must be 230 V/50 Hz AC. A separate fuse for the power supply is recommended.
To maintain the prescribed ambient temperature, mount the
OpenCom 100 in a well-ventilated location, away from direct sources of heat.
Do not position the OpenCom 100
■ in front of or above heat sources such as radiators,
■ in direct sunlight,
■ behind curtains,
■ in small, unventilated, damp rooms,
■ on or near inflammable materials,
■ or near high-frequency devices such as transmitters, X-ray or similar apparatus.
Use a separate 230 V power circuit and install overvoltage protection.
Installation Declarations of Conformity
17
Wall Mounting
The OpenCom 100 is mounted on the wall with three screws as shown in this diagram:
A
To fasten the screws at points B and
C, remove the cover of the
OpenCom 100 and insert the screws in the holes provided for this purpose. The OpenCom 100 is suspended from the screw at point A, so there must be a space of 3 mm between the screw and the wall.
B
184
Mounting plan
D
332
134
C
Available Ports
The OpenCom 100 has the following
ports (see also Positions of the Ports starting on page 22):
OpenCom 107
■
Four analogue a/b ports, designed as pressure terminals (a/ b1 to a/b4)
■
One actor ports for connection to a door opener, designed as pressure terminals (Actor)
■
One S
0
port for connection to an external S
0
bus (usually the
NTBA), designed as an RJ45 socket (S
0
1)
■
Two switchable S
0
ports (S
0
2 and S
0
3), which can be connected to either an internal or an external S
0
bus. The internal port is designed as a pressure terminal, the external port as an
RJ45 socket
■
One S
0
port for an internal S
0 bus, designed as a pressure terminal (S
0
4). S
0
4 can also be wired externally (as a master) when networking two
OpenCom 100 communications systems in a Q.SIG trunk (also re-
fer to PBX Networking starting on page 73).
18
Wall Mounting Installation
■
Four U pn
ports, designed as pressure terminals (U pn
1 to
U pn
4)
■
One LAN port (10BaseT), designed as an RJ45 socket
■
One COM port for connection to a PC for configuration or transfer of call data, designed as an RJ45 socket
■
One port jack to connect the plug-in power supply. Only use the original OpenCom 107 plugin power supply.
CAUTION! It is not allowed to operate the plug-in power supply inside the housing of the
OpenCom 107.
OpenCom 105
■
Four analogue a/b ports, designed as pressure terminals (a/ b1 to a/b4)
■
Two actor ports for connection to a door opener and entrance intercom system, designed as pressure terminals (Actor1 for activating a door opener and
Actor2 for activating an entrance intercom)
■
One sensor port for connection to the bell of an entrance intercom system, designed as a pressure terminal (sensor)
■
One PCM port for the connection of two systems, designed as an
RJ45 socket (PCM)
■
One S
0
port for connection to an external S
0
bus (usually the
NTBA), designed as an RJ45 socket (S
0
1)
■
Two switchable S
0
ports (S
0
2 and S
0
3), which can be connected to either an internal or an external S
0
bus. The internal port is designed as a pressure terminal, the external port as an
RJ45 socket
■
One S
0
port for an internal S
0 bus, designed as a pressure terminal (S
0
4). S
0
4 can also be wired externally (as a master) when networking two
OpenCom 100 communications systems in a Q.SIG trunk (also re-
fer to PBX Networking starting on page 73).
■
Four U pn
ports, designed as pressure terminals (U pn
1 to
U pn
4)
■
One LAN port (10BaseT), designed as an RJ45 socket
■
One COM port for connection to a PC for configuration or transfer of call data, designed as an RJ45 socket
Installation Available Ports
19
OpenCom 110
■
Four analogue a/b ports, designed as pressure terminals (a/ b1 to a/b4)
■
Two actor ports for connection to a door opener and entrance intercom system, designed as pressure terminals (Actor1 for activating a door opener and
Actor2 for activating an entrance intercom)
■
One sensor port for connection to the bell of an entrance intercom system, designed as a pressure terminal (sensor)
■
One PCM port for the connection of two systems, designed as an
RJ45 socket (PCM)
■
Two S
0
ports for connection to an external S
0
bus (usually the
NTBA), designed as RJ45 sockets
(S
0
1 and S
0
2)
■
Two switchable S
0
ports (S
0
2 and S
0
3), which can be connected to either an internal or an external S
0
bus. The internal port is designed as a pressure terminal, the external one as an
RJ45 socket
■
One S
0
port for an internal S
0 bus, designed as a pressure terminal (S
0
5). S
0
5 can also be wired externally (as a master) when networking two
OpenCom 100 communications systems in a Q.SIG trunk (also re-
fer to PBX Networking starting on page 73).
■
Eight U pn
ports, designed as pressure terminals (U pn
1 to
U pn
8)
■
One LAN port (10BaseT), designed as an RJ45 socket
■
One sync port for synchronisation with another telecom system, designed as a pressure terminal (Sync)
■
One COM port for connection to a PC for configuration or transfer of call data, designed as a 9-pin submin D port (V.24)
OpenCom 120
■
Four analogue a/b ports, designed as pressure terminals (a/ b1 to a/b4)
■
Two actor ports for connection to a door opener and entrance intercom system, designed as pressure terminals (Actor1 for activating a door opener and
Actor2 for activating an entrance intercom)
■
One sensor port for connection to the bell of an entrance intercom system, designed as a pressure terminal (sensor)
20
Available Ports Installation
■
One PCM port for the connection of two systems, designed as an
RJ45 socket (PCM)
■
Six switchable S
0
ports, which can be connected to either an internal or an external S
0
bus.
The internal port is designed as a pressure terminal, the external one as an RJ45 socket
■
18 U pn
ports, designed as pressure terminals (U pn
1 to U pn
18)
■
Two LAN ports (10BaseT), designed as RJ45 sockets. The second LAN port of the
OpenCom 120 is intended only for networking two
OpenCom 120/120 or 110/120 systems
■
One sync port for synchronisation with another telecom system, designed as a pressure terminal (Sync)
■
One COM port for connection to a PC for configuration or transfer of call data, designed as a 9-pin submin D plug (V.24)
Installation Available Ports
21
Positions of the Ports
The following diagrams show the positions of the ports on the
OpenCom 100 variants:
Default setting
LAN
COM S
0 ext
1 S
0 ext
2 S
0 ext
3
Position of ports on the OpenCom 107
S
0
2 int
S
0
3 int
S
0
4 int
U pn
1/2
U pn
3/4 a/b
1/2 a/b
3/4
Actuator
Default setting
Intercom/Relay
Intercom/Door opener
E
PCM LAN COM S
0
1 ext
S
0
2 ext
S
0
3 ext
Position of ports on the OpenCom 105
S
0 int
2 S
0 int
3 S
0 int
4 U pn
1/2
U pn
3/4 a/b
1/2 a/b
3/4
Actuator
1 + 2
Sensor
PCM LAN
Sync Sensor Default setting
Intercom/Door opener Intercom/Relay
E
S
0
1 ext
R
S
0
2 ext
R
S
0
3 ext
R
S
0
4 ext
R
S
0 int
3 S
0 int
4
Position of ports on the OpenCom 110
COM
R
S
0 int
5 Actuator
1 + 2
U pn
1/2
U pn
3/4
U pn
5/6
U pn
7/8 a/b
1/2 a/b
3/4
22
Available Ports Installation
PCM LAN 1 LAN 2
Sync Sensor Default setting
Intercom/Door opener Intercom/
Relay
U pn
9/10
U pn
11/12
U pn
13/14
U pn
15/16
U pn
17/18
S
0
1 ext
R
S
0 ext
2
R
S
0 ext
3
R
S
0 ext
4
R
S
2M
S
0
1 int
S
0
2 int
S
0
3 int
S
0
4 int
Position of ports on the OpenCom 120
COM
S
0 ext
5
R
S
0 ext
6
R
E
S
0
5 int
S
0
6 int
Actuator
1 + 2
U pn
1/2
U pn
3/4
U pn
5/6
U pn
7/8 a/b
1/2 a/b
3/4
Port Assignment, Termination,
Cable Lengths
S
0
Ports
Whether you use the switchable
S
0 ports for internal or external communication depends on your communications requirements and the existing basic accesses.
Note that the S
0
bus requires a terminating resistor of 100 ohms at each end. Resistors in the
OpenCom 110 and OpenCom 120 are marked with an “R” in the diagrams
Positions of the Ports on page 22 and
are implemented as switch hooks.
Open the switch if you do not wish to terminate the bus with the
OpenCom 100.
In the case of the OpenCom 107/
105, the S
0
buses are terminated by software. You make this setting in the S
0 port configuration in the Con-
figurator on the Web console.
You can connect up to eight terminals on every internal S
0
bus; up to three of the terminals can operate without an external power supply.
The length of the four-wire cable of an internal S
0
bus must not exceed
150 m. The power consumption of each internal S
0
bus is approx. 3 W.
Installation Port Assignment, Termination, Cable Lengths
23
OpenCom 120
R
TR
IAE IAE
The S
0
bus is terminated at one end by
the OpenCom 100; the hook switch is
closed.
IAE = ISDN socket (German: “ISDN Anschluß Einheit”) or an ISDN terminal.
TR = terminating resistor, the S
0
termination. The TR must be at the termination of the line. This can also be done by an appropriately wired IAE.
OpenCom 110
OpenCom 120
R
TR TR
IAE
IAE
The S
0
bus is terminated by the TR at the ends; the hook switch is open.
2a
2b
1a
1b
TR
TR
Termination on an ISDN socket
U
pn
Ports
Each of the U pn
ports enable the connection of an RFP 21/23 DECT base station or an OpenPhone 61, 63 or 65 telephone using a twin-wire cable.
The maximum permissible length of the twin-wire cable on a U pn
port of an interface card is 1,000 m when
0.6 mm cable (with twisted pairs) is used. The power consumption of each U pn
port is approx. 3 W.
U pn
/RFP with 1 U pn
S
0 int
2a 2b 1a 1b
1 2 3 4 5 6 7 8
RFP with 2 U pn
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Pin assignment of the S
0
and
U pn ports
a/b Ports
The a/b ports are for operating analogue devices (a fax machine, modem or telephone). The maximum permissible length of the cable is
1,000 m when twin-wire 0.6 mm cable (with twisted pairs) is used.
If an entrance intercom system is connected to a/b1, the switch
marked “E” on the diagram Positions
24
Port Assignment, Termination, Cable Lengths Installation
of the Ports starting on page 22 must
be open in order to isolate the low frequency voltage from the supply
(see also the following section enti-
tled Actor/Sensor on page 25).
Note: With the newer structure of
the communications system, the switch is electronic. For this reason, there is no “E” switch with this structure.
Actor/Sensor
In order to operate an entrance intercom and door opener, you need four twin-wire cables:
■ one cable between the entrance intercom and the a/b1 port,
■ one cable between the door opener and the Actor1 port
(marked Intercom/Door opener
in the diagram Positions of the
■ one cable between the intercom input and the Actor2 port
(marked Intercom/Relay in the
diagram Positions of the Ports starting on page 22) to activate
the amplifier as well as
■ one cable between the doorbell and the sensor port.
Only use entrance intercoms and door openers complying with the
German FTZ Guideline no. 123D12.
LAN Port
The LAN port (OpenCom 120: LAN 1 port) enables integration of the
OpenCom 100 into an existing inhouse LAN by means of a 10 Mbit hub.
A LAN line (twisted-pair line in accordance with 10BaseTcan be up to
100 m long. Use a shielded Ethernet cable (STP cable, Shielded Twisted
Pair cable).
The second LAN port of the
OpenCom 120 is intended only for networking two OpenCom 120/105,
120/110 or 120/120 systems.
DSL Port
External DSL modems can be connected via the LAN port. In the case of the OpenCom 100, the output of the DSL modem (NTBBA) is led to the
LAN port of the OpenCom 100
(LAN 1 in the case of the
OpenCom 120) via an external switch or hub. The router subse-
quently converts the PPPoE protocol
to the TCP/IP protocol of the LAN.
Installation Port Assignment, Termination, Cable Lengths
25
OpenCom
TAE
DSL & Uk
0
S
0
Net
DSL
Splitter
TCP/IP &
PPPoE
DSL
Uk
0
NTBA S
0
PC
Crosslinked twisted pair cable
PPPoE
TCP/IP
DSL
Modem
Hub
Connecting the OpenCom 100 to the network via ISDN and DSL
Net
Basic Setting Switch
Connection of the DSL modem is via a crossover twisted-pair line. You can also use a switchable port on the hub, which is usually indicated by an
“X”.
Using the basic setting switch, it is possible to reset the OpenCom 100 system to the factory configuration
(see Factory Settings on Delivery starting on page 10).
PCM Port
The position of the switch can be
seen in the diagram Positions of the
The PCM port is used to connect two
OpenCom 120 systems, or an Open-
Com 110 with an OpenCom 120 system by a special transmission procedure called pulse code modulation.
The RJ45 cable used must not exceed 4 m in length.
Sync Port
The twin-wire Sync port is used when the OpenCom 100 serves as a subsidiary system for a main system that is a DECT system.
Please note: The current configu-
ration data is lost, the system is reset to the default configuration. For this reason you should back up your configuration regularly, the best time being after every change. For details, re-
fer to the chapter entitled Saving and
Loading the Configuration starting on page 59 and to the Web console on-
line help documentation.
26
Port Assignment, Termination, Cable Lengths Installation
Power Failure
In the event of a power failure, all the contents in the memory (program and user data) are saved without change. The internal clock continues to run for 24 hours. If the power failure lasts longer than
24 hours, the time and date are reset to the factory setting when power is switched on again. When the first external outgoing call is made, the time and date are set to the current value as given by the exchange.
On the multi-terminal access, the
OpenCom 105, the OpenCom 110 and the OpenCom 120 include an emergency service. In the event of a power failure, the external S
0
1 port is switched over to the internal S
0
5 port (in the OpenCom 105to the S
0
4 port) so that you can still use a connected telephone to make a call.
Emergency operation on a system access is not possible.
Connectible Devices
The OpenCom 100 ports offer a large number of possibilities for connecting devices. One of the many possible configurations is shown in the following diagram:
Hub
Intercom/Relay
Intercom/Door opener
LAN
Sensor
S
0
1 ext S
0
2 ext S
0
3 ext S
0
4 ext
R R R R
NTBA NTBA NTBA NTBA
COM
E
R
S
0
5 int
Actuator
1 + 2
U pn
1/2
U pn
3/4
U pn
5/6
U pn
7/8 a/b
1/2 a/b
3/4
Example of port assignment of the OpenCom 110 with terminals
Installation Power Failure
27
Internal/External
S
0
Ports
The S
0 ports
■
S
0
2 and S
0
3 (OpenCom 107/105)
■
S
0
3 and S
0
4 (OpenCom 110)
■
S
0
1 to S
0
6 (OpenCom 120) can either be connected externally
(i.e. to ISDN network terminators) or internally; simultaneous use of both is not possible.
The S
0
4 internal (OpenCom 107/105) or the S
0
5 internal (OpenCom 110) can also be wired externally (as a master) when networking two
OpenCom 100 communications systems in a Q.SIG trunk (also refer to
PBX Networking starting on page 73).
Up to eight devices per bus (ISDN telephones, ISDN fax machines, ISDN base stations, ISDN cordless telephones, ISDN adapters for the PC) can be connected to the internal S
0 ports by twin-pair cables. The power for three of these devices can be supplied by the bus; if more devices are used, they then require their own power supplies. The internal S
0 buses enable point-to-multi-point calls as per the DSS1 protocol (Euro-
ISDN).
U
pn
Ports
A system terminal can be connected to every U pn
port by a twin-wire cable. The OpenPhone 61, OpenPhone
63 and OpenPhone 65 are cordbound system terminals. The Open-
Phones 63 and 65 can be cascaded on a U pn
adapter so that you can operate two OpenPhones on one U pn port. For further details, refer to the
“OpenPhone 61, 63, 65” user guide.
The RFP 21 base station is required for the use of cordless system telephones (e.g. OpenPhone 21 or
OpenPhone 25). The OpenPhone 25 features a V.24 port on which you can transfer data and surf on the Internet.
If this base station is connected to a
U pn
port, four simultaneous calls are possible with the mobile parts. If the base station is connected to two U pn ports, eight simultaneous calls are possible. However, note that only as many external connections are possible as there are connected B-channels available.
If you use a cordless handset such as the OpenPhone 21, this can also be contacted by other base stations using the GAP/CAP standard.
You can also operate the
OpenPhone 52 ISDN terminal on a
U pn
port.
28
Connectible Devices Installation
a/b Ports
The a/b ports a/b1 to a/b4 can be used for connecting analogue terminals. These can be for voice or data communication, and use DTMF or pulse dialling, e.g.
■ analogue telephones
■ class 3 fax machines
■ analogue modems (external or internal)
■ external devices for music on hold
■ external voice mail systems.
Please note: Adhere to the fol-
lowing notes and recommendations regarding the connection of analogue devices. Devices not meeting the technical requirements of the
OpenCom 100 can cause damage to it.
Analogue Telephones
If analogue telephones are to be used, we recommend the use of devices featuring voice-frequency (VF) signalling, as the additional features of the OpenCom 100 cannot be used with pulse dialling.
Modems
The maximum transmission rate for analogue modems is 33.6 kbit/s
(V.34+).
Music on Hold
A suitable external device for music on hold is the Genius 2000, manufactured by Speech Design. If you do not operate an external MoH device, the Access 5000 offers an internal
MoH, which you can load in the Web console Configurator, SYS Configu-
ration: Components menu. For details, refer to the online Help.
Please note: Use only devices
with an input impedance of
600 ohms, floating connection, for external music on hold. Incorrect input impedance can cause irreparable damage to the OpenCom 100.
Voice Mail
If you are using an external voice mail system, it must be capable of handling the number of digits used for internal telephone numbers, e.g. five digits if you have configured five-digit internal numbers. We recommend the following Speech Design products: Memo 200/300/400 or Memo 200-A/300-A/400-A.
The external voice mail system can be connected to internal a/b ports as well as to internal S
0
ports. For both port types the voice mail system can activate the notification for system terminals with the code procedures
* 6 8 resp. # 6 8 .
Installation Connectible Devices
29
Intercom System (for a/b)
The intercom systems “DoorLine
T01/02” and “DoorLine T03/04” of the german Telekom’s division
T-Com can be connected via the
“DoorLine M06” to any a/b port. The
“Doorline” module provides the actor for the door opener contact.
Observe the following for connection and use of the intercom system:
■
The intercom system and the
“Doorline” module should be set to their factory settings.
■
In the PBX Configuration:
Ports: a/b: Change menu in the
Configurator, select Doorline under Type. Activate the Actua-
tor option, if you want to use the actor port of the OpenCom 100 instead of the “DoorLine” relay.
The “DoorLine” actor can be operated only when the speech channel is open at the same time. The internal actor can be operated at any time.
■
The “Doorline” intercom system has a number of bell keys to which you can assign different call numbers in the
PBX Configuration: Ports:
Doorline menu in the Configurator.
■
You can call the “Doorline” intercom system by entering the code procedure * 1 0 2 .
■
The “Doorline” intercom system can be connected to any a/b port. However, you can use only one “Doorline” with the
OpenCom 100.
For details on installing and configuring the “Doorline” intercom system, refer to the product user guide.
The intercom system should be installed by qualified personnel only as sensor/actor contacts will need to be connected for this procedure.
30
Connectible Devices Installation
Actor/Sensor Ports
For the assignment of the ports, re-
fer to the section Available Ports starting on page 18. The
OpenCom 100 also functions together with a Freehand Entry-Phone manufactured by Siedle or Behnke.
a/b1
Relay
Actor2
Actor1
Door opener
To
Ts
-T
+T
To
Ts* b a
PVG 402-0
Amplifier
LW
1
12 c1
7
11
9
+
Sensor
230 V ~
NG 402-02
Ac adapter b c
+
9
-
12 V ~
Connection of doorway equipment produced by Siedle
Note: The above diagram shows
the usage of the “PVG 402-0” module
(which merely serves as an example).
Other modules can also be operated, such as its successor, “PVG 602-01”.
9
+
11
12
Siedle
Door bell
Installation Connectible Devices
31
COM Port
Please note: The connection line
for the COM port can be up to three metres long.
A PC for configuring the
OpenCom 100 or transmitting call data can be connected to the COM port. This call data can be evaluated in detail with the call charge registration program OpenCount.
LAN Port
Using the LAN port (Ethernet) you can integrate an OpenCom 100 into your corporate network (local area network), and thus use it, among other things, as an IP router for accessing the Internet.
The OpenCom 120 has a second LAN port for cascading your telecom system with another OpenCom 105,
OpenCom 110 or OpenCom 120 (see
PBX Cascading starting on page 73).
32
Connectible Devices Installation
Accessories and Adapters
The OpenPhone 63 and
OpenPhone 65 system telephones have one or two slots on the rear for various adapters and other accessories. Further information on installing and operating these add-ons can be found in the “OpenPhone 61, 63,
65” user guide under “Add-ons (with
& without an Adapter)”.
Note: An extra plug-in power sup-
ply is required to operate combinations of equipment with a power consumption that exceeds the power output of the U pn
ports.
a/b Adapter
In the following you will find technical details on the add-ons and a list of compatible accessories.
You can use an a/b adapter to connect analogue terminals to the
OpenPhone 63 and OpenPhone 65 system telephones.
U
pn
Adapter
The U pn
adapter is an adapter with a
U pn
port for connecting another
OpenPhone 61, 63, 65 system telephone and a socket for an extra plug-in power supply.
Weight: 70 g
Dimensions: 73 x 60 x 30 mm
Power consumption: max. 195 mW
Cable length: max. 30 m
Please note: The U
pn
adapter may be used only for connecting the system terminals listed above. The
U pn
extension cable must not exceed
30 m in length and must not be used outdoors.
Connecting an a/b adapter will result in exceeding the feed performance of the U pn
port, regardless of the range. Therefore a plug-in power supply must be additionally connected to the a/b adapter.
Note: Please use the plug-in power
supply with the product code
4505759. The plug-in power supply for use in the UK has the product code
4510694.
Weight: 70g
Dimensions: 73 x 60 x 30 mm
Power consumption: max. 160 mW
Cable length: max. 3 m
Accessories and Adapters
33
Audio Adapter
The audio adapter is an adapter extension with four different ports for external audio and signalling devices.
Audio Adapter Pin Assignment
Port
1
2
3
4
Weight: 70g
Dimensions: 73 x 60 x 30 mm
Power consumption: max. 260 mW
(with relay active).
Used for
Ear cap, second handset, headset, active speaker or microphone
Socket
RJ-10
(4-pin
Western socket)
Assignment
1: microphone -
2: speaker +
3: speaker -
Recording device; relay contact generates signal for starting and stopping recording.
Not used on
OpenCom 100
Door display
Stereo jack,
3.5 mm
4: microphone +
1 (GND): recording signal, relay contact 1
2 (peak): recording signal +
-
3 (ring): relay contact 1
Round power socket
(4 mm)
RJ-11 or
RJ-12
(6-pin
Western socket)
4, 5: relay contact 2
1, 2, 3, 6: NC
34
Accessories and Adapters
Electrical Data of Ports
Port
Microphone, microphone of second handset, headset microphone
Ear cap, loudspeaker of second handset, headset, headset loudspeaker
Active speaker
Recording device audio input
Recording device start/stop
(relay contact 1)
Door display
(relay contact 2)
Connection Values
Electret microphone
Typical sensitivity: 10 mV/Pa
Power feed: I < 300 µA at 1.5 V
Typical impedance: 150 ± 30 ohms
Typical sensitivity: 94 dB/1 mW
(0 dB = 20 µPa)
Max. output voltage: 1 V rms at input impedance > 10 kohms
Typical input sensitivity: 0.24 mV
(microphone level)
Max. switching voltage: 50 VDC/29 V AC
Max. switching current: 1 ADC/0.7 A AC
Max. switching voltage: 50 VDC/29 V
A
C
Max. switching current: 1 ADC/0.7 A AC
Accessories and Adapters
35
Approved Devices /
Approved Accessories
Please note: Only the following,
recommended accessories may be connected to the audio adapter. The cable to the door display must not be run outdoors.
The following devices are recommended:
Type
Headset:
Headset adapter cable:
Second handset
Handset
Microphone:
Loudspeaker:
Recording device:
Manufacturer, Product Designation
GN-Netcom, Profile binaural (1869-00-03)
GN-Netcom, Profile 3-in-1 (1866-00-04)
GN Netcom, QD cable (quick coupling), smooth,
Mod 4 (8800-00-01)
Siemens, L30351-F600-A366
DeTeWe, OpenPhone 60
Winfinity, 4511326 / H 282-18
Siemens, L30460-X1278-X
No recommendation
36
Accessories and Adapters
Device Combinations
These symbols are used in the following tables:
You can use the following power values to calculate the power consumption of combined equipment:
■
U pn
adapter: 195 mW
■
Audio adapter: 260 mW
■ a/b adapter: 160 mW
(must be combined with a plugin power supply!)
●
This combination is possible.
❍
Reduced tone ringing, open listening and hands-free talking volume possible.
Configurations without
Plug-in Power Supply
(Range up to 500 m)
■
OpenPhone 61: 1,000 mW
■
OpenPhone 63: 1,025 mW
The following table shows examples of equipment combinations for which the maximum power consumption of 2.4 W is not exceeded.
■
OpenPhone 65: 1,140 mW
■
Up to three add-on keypads:
330 mW
Basic Unit: OpenPhone 63
–
●
Add-ons
Audio adapter U pn adapter Up to 3 keypad modules
– –
–
–
–
●
●
–
–
–
Second Terminal Power
–
–
OpenPhone 61
OpenPhone 63 without adapter
1025 mW
1285 mW
2220 mW
2245 mW
–
●
– 2360 mW OpenPhone 65 without adapter or keypad module
Accessories and Adapters
37
Basic Unit: OpenPhone 65
–
–
–
●
Add-ons
Audio adapter U pn
adapter Up to 3 keypad modules
– –
–
–
●
●
–
●
●
–
–
Second Terminal Power
–
–
–
OpenPhone 61
OpenPhone 63 without adapter
1140 mW
1470 mW
1730 mW
2335 mW
2360 mW
–
❍
– 2475 mW OpenPhone 65 without adapter or keypad module
Configurations without
Plug-in Power Supply
(Range 500 to 1000 m)
The following table shows examples of equipment combinations for which the maximum power consumption of 2.2 W is not exceeded.
Basic Unit
OpenPhone 63
OpenPhone 65
Add-ons
–
●
Audio adapter U pn
adapter Up to 3 keypad modules
●
– –
–
–
●
●
Power
1285 mW
1470 mW
1730 mW
38
Accessories and Adapters
Configurations with
Plug-in Power Supplies
The following table shows examples of equipment combinations operating with additional power from a plug-in power supply.
Basic Unit: OpenPhone 63
Add-ons:
Up to 3 keypad modules
Audio adapter
Second terminal
●
●
●
U pn
adapter and plug-in power supply
OpenPhone 61 OpenPhone 63 without adapter
OpenPhone 65 without adapter and with 1 keypad module
●
●
●
●
●
●
●
●
●
Basic Unit: OpenPhone 65
Add-ons:
Up to 3 keypad modules
Audio adapter
●
●
●
Second terminal
●
●
●
●
●
●
U pn
adapter and plug-in power supply
OpenPhone 61 OpenPhone 63 without adapter
OpenPhone 65 without adapter and with 1 keypad module
●
●
●
●
●
●
Accessories and Adapters
39
S
2M
Connector Module
The S
2M
connector module allows you to operate an OpenCom 120 on a primary rate access. This access provides up to 30 voice channels.
You can also use the S
2M
port to network two systems, e.g. in order to use the OpenCom 120 as a subsidiary system or DECT server.
Note: The maximum cable attenu-
ation between the OpenCom 120 and the other system (NT or telephone exchange) must not exceed 6 dB. This corresponds to a length of approx.
150 to 200 m, depending on the type of cable used.
PCM LAN 1 LAN 2
Sync Sensor Default setting
Intercom/Door opener Intercom/
Relay
U pn
9/10
U pn
11/12
U pn
13/14
U pn
15/16
U pn
17/18
S
0 ext
1
R
S
0 ext
2
R
S
0 ext
3
R
S
0 ext
4
R
S
0 ext
5
R
S
0 ext
6
R
E
COM
S
2M
S
0
1 int
S
0
2 int
S
0
3 int
S
0
4 int
S
0
5 int
S
0
6 int
Actuator
1 + 2
U pn
1/2
U pn
3/4
U pn
5/6
Location of the S
2M
port on the connector module of the OpenCom 120
U pn
7/8 a/b
1/2 a/b
3/4
Installation
Please note: The module should
only be installed by trained personnel.
DANGER! The device contains hazardous voltages.
2. Open the housing of the
OpenCom 120.
3. For some models of the
OpenCom 120 a separate module cover exists. Remove the cover of the module. To do this, push back the two locking levers, (1) and (2), and lift off the cover.
1. Pull out the mains plug of the
OpenCom 120.
40
S
2M
Connector Module
1 2
1 2
3
4
S
2M
LEDs
S
2M
slot
(Underside of the module board)
Removing the module cover
4. On the module board, remove the protective covers of the two
S
2M
slots (3) and (4).
S
2M
slots
4
3
Activity LED
PCM LAN 1 LAN 2
Position of the S
2M
slots on the module board
5. Insert the S
2M
module into the slots, making sure you insert the
LED side of the module into the upper slot (4).
Position of the LEDs on the
S
2M
module
6. Replace the module cover. To do this, insert the locking hooks at the lower end of the cover into the recesses on the connection module. Press the module cover until the upper locking levers engage.
7. Wire the S
2M
port of the connector module to the NT or the other PBX according to the following drawing. Make sure the
RX and TX lines are crossed over
(connect the RX lines of the
OpenCom 120 to the TX lines of the other PBX).
S
2M
Connector Module
41
PBX 1, S
2M
Rx+ Rx- Tx+ Tx-
Rx+ Rx- Tx+ Tx-
PBX 2, S
2M
(Pressure clamps)
Example of the wiring of the S2M port
for two OpenCom 120s
8. If necessary, check to make sure that the NT is fed by its own power supply.
9. Reconnect the OpenCom 120 to the power supply.
10. Configure the S
2M
module in the Configurator of the
OpenCom 120 (refer to Configu-
Check the level 1 status with reference to the LEDs on the module. None of the LEDs are illuminated before the S
2M
module has been configured.
LED Displays
LED Meaning
1 (green) Synchronous (= ok)
2 (green) Blue alarm
3 (yellow) Remote alarm or out of sync
(yellow alarm)
4 (red) Loss of signal (red alarm)
11. Pull out the mains plug of the
OpenCom 120 again and close the housing.
12. Reconnect the OpenCom 120 to the power supply.
Configuration
The menu item S
2M
appears in the
Configurator, menu PBX Configura-
tion: Ports after installation of the
S
2M
module. Configure the port in the input mask of this menu item.
Further information on this can be found in the online help.
If the menu item S
2M
is not displayed,
check whether or not the firmware has to be updated. You need software release 3.0 or higher. The current firmware version is given in the menu
System Info: Versions.
42
S
2M
Connector Module
Mounting the OpenCom 110/
120 Rack InfoCom System
Safety Precautions
The system needs to be mounted in earthed cabinets or cases. Lines and cables connected to the system must only be laid inside buildings.
Use a shielded Ethernet cable (STP cable, Shielded Twisted Pair cable) to connect the OpenCom 100 to a Local
Area Network (LAN).
The ambient temperature of the
OpenCom 110/120 Rack infocom system should not exceed 55°C. If the device is installed together with other active components, it may be necessary to mount additional ventilation fans in the installation cabinet.
Patch cables have to be connected before connecting the system to the power supply. Installation of the system, and in particular connection to the power supply and protective earthing, should only be performed by skilled, qualified personnel. EN,
IEC regulations, along with other recognised technical rules regarding safety, must be observed.
Please note: Before opening the
device, pull out the plug.
Technical Data
(only if different from the
OpenCom 110/120)
Dimensions:
– Width: 19-inch panel with flange for mounting in installation cabinet
–Height: 3U
– Depth: approx. 340 mm
Weight:
approx. 5.2 kg
Connection of 230 VAC power supply on rear side via inlet connector for non-heating apparatus
Connection of all ports via RJ 45 jacks on front panel
Note: The ISDN S
0
ports on the front panel may only be switched in one direction (internal or external).
Use of the external port with a crossover (Rx-Tx) patch cable in parallel to the S
0
internal port (for two S
0
terminals on the same bus) may severely limit the range of the S
0
bus.
Mounting the OpenCom 110/120 Rack InfoCom System
43
Pinning of RJ 45 Jacks
U pn
, a/b, Sensor,
Actor
S
0
S
2M
10Base-T
PIN 4-5
PIN 4-5, 3-6
PIN 4-5, 1-2
PIN 1-2, 3-6
Switches on Front Panel
■
The bus termination resistors for all the S
0
internal ports are switchable.
Please note: In the factory set-
ting on delivery, the switches are open, i.e. the termination resistors are not switched on.
■
The internal S
0
bus is terminated at one end (NT) by the
OpenCom 110/120 Rack with
100
Ω termination resistors; the
DIP switches below the respective RJ jacks are “on” (i.e. closed) in the upper position.
Please note: Both S
0
bus switches must be in the same position.
■
The S
0
bus is terminated at both ends with 100
Ω termination resistors; the DIP switches below the respective RJ jacks are “off”
(i.e. open) in the lower position.
■
The DIP switches on a/b port 1 are normally “on” (i.e. closed) in the upper position. If the device is set for the entrance intercom port, the switches must be in the lower position (“off”).
Scope of Delivery
■
Adapter cable RJ 45 - RS 232 for
V.24/COM interface
■
Screws for rack mounting
■
For complete installation the country-specific installation package is necessary. It contains the power cord, a complete set of manuals and a CD-ROM.
Note: Note for the DeTeWe in-
staller: Please download and install the latest released software from our
Web site/partnership area.
44
Mounting the OpenCom 110/120 Rack InfoCom System
Configuration
Configuration and programming of the OpenCom 100 is performed by the Configurator, a special software application integrated into the system. The Configurator is operated via the Web console, which can be run on any PC connected to the
OpenCom 100.
The OpenCom 105 Web console
Using the Web console, you can:
■ perform the initial configuration of the OpenCom 100,
■ configure users of the
OpenCom 100 and authorise them to use certain system services,
■ carry out further system maintenance,
■ use PC-supported telephony functions,
■ read out call charge information,
■ access the OpenCom 100 telephone book.
The Web console has an integrated online help function that offers comprehensive information on configuration and maintenance of the
OpenCom 100 (see Loading the On-
line Help starting on page 56).
Note: In order to use all the new
system software functions, we recommend that you download the latest software from our Web site at http://www.detewe.com.
For the initial configuration you can connect the PC to the OpenCom 100
Configuration
45
via the Ethernet port. A COM port can also be used. The TCP/IP network protocol is used to set up a connection via one of these ports. You can then open the Web console of the
OpenCom 100 and call up the Con-
figurator from there.
Note: This chapter describes initial
configuration of the OpenCom 100.
For day-to-day operation you can integrate the OpenCom 100 into a LAN
and start the Configurator from any
PC. For information on how to do this,
refer to the Configuration Examples starting on page 62.
Brief Guide to Initial Configuration
Setting up a first connection is quite simple with a standard Windows PC:
1. Turn off the PC. Remove all connected network cables.
2. Connect the PC network card to the LAN port. Use a cross-wired
Ethernet cable to do this.
3. Restart the PC. If you manually deactivated the automatic configuration of the network card via DHCP, you must reactivate this and again restart the computer.
4. Start the Web browser. In the address field, enter
“http://192.168.99.254/”.
The login page of the Web console will then open. For further details,
please refer to Configuring the
OpenCom 100 starting on page 54.
First Configuration via
Serial Port
1. The serial port can also be used as alternative access for the first configuration.Additionally, you require a crossed serial line
(“null modem”).Install the “occonfig” program from the system CD. To do this, you must log on as an administrator under
Windows NT or Windows 2000/
XP.
2. Shut down the PC. Remove all connected network leads. Connect the serial port of the PC to the COM port of the
OpenCom 100. Use the connecting cable that is supplied.
3. Restart the PC. Set up an RAS link with the icon configured on the desktop under step 1. Enter
“Administrator” without a password as your user name.
46
Brief Guide to Initial Configuration Configuration
4. Start the Web browser. Enter
“http://192.168.99.254/” in the address box.
You will see the log-on page of the
Web console. Continue reading un-
der Configuring the OpenCom 100 starting on page 54.
System Requirements
Note: If no connection can be es-
tablished by following the instruc-
tions in the Brief Guide to Initial Configuration starting on page 46, refer
to the more detailed explanations below.
A normal TCP/IP-capable PC with a
Web browser is required for the initial configuration. The PC should at least meet the following requirements:
■
IBM-compatible 200 MHz PC
■
32 MB RAM and 50 MB of free hard disk space
■
Microsoft Windows 95/98,
Microsoft Windows 2000/XP or
Microsoft Windows NT 4.0 operating system
■
Microsoft Internet Explorer version 4.0 or higher, or Netscape
Communicator version 4.5 or higher
Note: Microsoft Internet Explorer is
already installed in current versions of the Microsoft Windows operating system. If required, a Web browser can be installed from the system CD delivered with the OpenCom 100.
In addition, the selected type of connection requires further system components that you may have to install on your PC. The driver software is normally supplied with the hardware, and the appropriate version should be available for your operating system. You will find the system software on the installation CD of your operating system.
For connection on the V.24 port
(COM port) you need:
■
Hardware: one free serial port
(RS-232, V.24) and a serial cable
(SUBD9). For configuration of the OpenCom 105, use the adapter cable supplied for connecting RS-232 to RJ-45.
■
System software: serial port driver and TCP/IP protocol software
■
Driver software: RAS adapter software for installation on the
Configuration System Requirements
47
service PC (is included on the
CD)
For connection by network card you need:
■
Hardware: network card with
10BaseT port and RJ-45 network cable (crossover twisted pairs or connection via a hub)
■
Software: network card driver and TCP/IP protocol software
For connection on an S
0
port you need:
■
Hardware: (passive) ISDN card
■
Software: ISDN card driver, RAS adapter software and TCP/IP protocol software.
Configuration under Windows
Before beginning initial configuration, install the necessary hardware and matching driver software on the
PC. Follow the installation instructions supplied with the hardware. In many cases, the TCP/IP system software is installed together with the driver software for the hardware.
When you have installed the driver software, proceed as follows:
Note: The following steps are not
necessary under Windows 2000/XP. If possible, use a network card connection as network cards are easier to configure and feature higher data transfer rates. For more information
please read Connection by Network
Card (LAN) starting on page 51
1. Open “Network Settings” in the
Control Panel of your PC. To do this, you select the item “Settings > Control Panel” from the
Start menu and double-click on the “Network” icon. Under Windows NT, select the “Protocols” tab.
2. Check the list of installed components to see whether the TCP/
IP protocol is present. If necessary, install TCP/IP by clicking on the “Add” button.
3. Select “TCP/IP” from the “Protocol/Microsoft” folder and confirm your entry with “OK”.
4. Then follow the installation instructions displayed.
Depending on the type of connection (network card, S
0
port or V.24) you select, note the following when installing the driver and system software.
48
Configuration under Windows Configuration
Connection on Serial Port
(V.24)
The required components are normally ready installed together with the operating system. In this case, you can easily configure the connection to the OpenCom 100 by using the program “occonfig”:
Note: Under Windows NT or Win-
dows 2000/XP you must log on as an administrator.
1. Insert the system CD supplied along with the OpenCom 100.
The CD starts automatically if your PC is configured accordingly. Otherwise select “Run” in the Start menu. Use the
“Browse” button to find the
“cd_start.exe” program on the
CD. Confirm your entry with
“Open” and “OK”.
2. Select the “Software, installation program for RAS network link” option from the start mask. Click on “OK” to install the modem driver.
3. In the dialogue that follows, select a serial port and confirm this with “OK”.
After restarting your computer, you will find an icon for the connection to the OpenCom 100 on your desktop.
Note: If this procedure cannot be
completed properly, refer to the sec-
tion entitled Notes on Configuring the
Establishing a Remote Data
Transfer Connection
1. Connect the serial port of the PC to the OpenCom 100 COM port.
Use the V.24 serial connector cable supplied with the
OpenCom 100 (for the
OpenCom 105 use the adapter cable for connecting RS-232 to
RJ-45).
2. Double-click on the OpenCom desktop icon created with the
“occonfig” program.
3. In the dialogue which follows, enter the user name and password valid for the OpenCom 100 user account being used. For the initial configuration, log on under the user name “Administrator” without giving a password.
Clear any entries in the “Domain” box and confirm this with
“OK”.
When the connection is established, all necessary IP address parameters will be transmitted by the OpenCom 100 using the
PPP protocol and automatically set for the direct PC link.
4. Once set-up of the connection is confirmed, you can continue
Configuration Configuration under Windows
49
with Testing the Setup starting on page 52.
Note: It is not possible to operate a
network card and a remote data transfer connection for the same network address range simultaneously.
For this reason you must temporarily deactivate the network card when you want to establish a remote data transfer connection. To do this, open the “System” icon in the Control Panel and deactivate the network card in the “Devices” tab. If the PC is configured via DHCP, you can instead also disconnect the PC from the LAN and reboot it.
Notes on Configuring the
Serial Port
A serial port is automatically detected when the PC boots and the corresponding system software is installed. The TCP/IP connection to the
OpenCom 100 is established by means of additional system software: the RAS adapter software and the serial port driver.
Tip: The serial port that you use is operated with the parameters
57,600 baud, 8 data bits, 1 stop bit, no parity and no hardware data flow control.
Note: The RAS network is always
installed under Windows 2000/XP and cannot be uninstalled. The following section is only relevant for users of old Windows versions.
Installing the RAS Network under
Windows 95 or Windows 98
1. Open the Control Panel and double-click on the “Software” icon.
2. Click on the “Windows Setup” tab and double-click on the item
“Communications”.
3. Tick the check box next to the component “RAS Network” and confirm your entry with “OK”.
Installing the RAS under
Windows NT 4.0
1. Open the Control Panel and double-click on the “Network” icon.
2. Select the “Services” tab and click on the “Add” button.
3. Select “Remote Access Service” from the list and confirm with
“OK”.
4. To conclude installation of the
RAS, the RAS “Properties” dialogue is displayed. Select the driver “OpenCom Modem” that was created on the first start of the program “occonfig” and confirm this with “OK”.
5. Confirm the configuration with the “Continue” button and close the network settings.
50
Configuration under Windows Configuration
Note: If you have installed an oper-
ating system update earlier (Service
Pack), install this again after installation of the RAS.
Connection by Network
Card (LAN)
First-time configuration of the
OpenCom 100 is also possible by a network card, providing this is already installed on the PC, of course.
When the driver software for a network card is installed, the necessary system software for the TCP/IP protocol is installed at the same time.
During this process you should activate the automatic assignment of IP addresses by the DHCP protocol.
If the PC has been operating in a network to date, you should activate the automatic assignment of an IP address.
1. To do this, you select “Settings >
Control Panel” in the Start menu. Double-click on the “Network” icon. Under Windows NT select the “Protocols” tab. Under Windows 2000/XP right click on the “LAN Link” icon. Select
“Properties”.
2. Double-click on the item “TCP/IP
Protocol > Network card”. Activate the option “Obtain an IP address from a DHCP server” in the
“Properties” dialogue. Gateway or DNS entries must be deactivated.
Note: Changes to the Gateway and
the DNS configuration are made by
DHCP.
Establishing a Network
Connection
1. Connect the PC network card to the OpenCom 100 network port.
To do this, use either a crossover twisted-pair network cable or connect the OpenCom 100 via a hub.
Note: For initial configuration, it
may be wise not to connect the
OpenCom 100 to an existing LAN in order to eliminate conflicts with an existing DHCP server.
2. Restart your PC. During the system start, all necessary IP address parameters will be transmitted by OpenCom 100 via
DHCP and automatically set for the network card.
Note: If the PC has been operating
under Windows NT in a network with a Windows NT domain, you will not be able to log on to the domain. So log on to the PC domain as the local user “Administrator”.
3. Continue reading under Testing
the Setup starting on page 52.
Configuration Configuration under Windows
51
Connection via the
S
0
Port
First-time configuration of the
OpenCom 100 is also possible by way of an internal S
0
port. To do this, remote configuration must first have been enabled by a connected termi-
nal (see the section called Remote
Configuration starting on page 57).
1. Use the ISDN cable to connect a
PC, fitted with an ISDN card, to the internal S
0
port.
On delivery, the S
0
ports of the
OpenCom 100 are assigned as follows:
– OpenCom 105: S
0
3 and S
0
4
– OpenCom 110: S
0
3 to S
0
5
– OpenCom 120: S
0
3 to S
0
6
2. Set up an RAS connection to the
OpenCom 100 through the call number “398504”.Enter the user name “Administrator” and the arranged session key as the password.
Testing the Setup
Subsequent to establishment, test the TCP/IP connection between the
OpenCom 100 and the PC.
1. Select the item “Run” in the
Start menu. Enter the command
“ping host.domain” or
“ping 192.168.99.254” in the
“Open” box.
2. Confirm this with “OK”.
Tip: To find the IP address of the
Web console, enter * 1 8 2 on a connected system telephone.
* 1 8 3 will also show you the network mask.
You can test the correct IP configuration under Windows 95 and Windows 98. Select the item “Run” in the Start menu. Enter the command
“winipcfg” in the “Open” box. Confirm this with “OK”. Select the network adapter used for connection to the OpenCom 100. The IP addresses assigned by the OpenCom 100 on establishment of the connection will be displayed.
Under Windows NT4, 2000 and XP you can check the IP configuration by entering the commands “ipconfig
-all” or “route print” in the command prompt. The command “arp -a” produces a list of assigned IP addresses for LAN links.
Starting the Browser
Start the installed Web browser.
When you start the Microsoft Internet Explorer for the first time, the Internet access wizard will automatically appear. Select the option “Use existing account” and confirm this with “OK”.
52
Configuration under Windows Configuration
If the PC has been operating in a network or used for Internet access, it is possible that access may be configured indirect via a proxy server. Deactivate access via a proxy server
(“Direct connection”). To do this in the Internet Explorer, open the Internet options in the menu “Tools > Internet Options”, then select the
“Connections” tab. In Netscape Communicator, you select the command
“Edit > Settings” and then select the section “Extended > Proxies” under
“Category”.
Note: Reset your browser’s options
for the call-up of pages to their default settings specified on initial installation of the browser.
Configuration for Linux and MacOS
All modern operating systems support the TCP/IP protocol. You can find detailed information on setting up hardware and software for the
Windows operating systems under
Configuration under Windows starting on page 48. In this section there
are tips on integrating Linux and
MacOS operating systems.
“dhclient” package and activate configuration via DHCP in the Linux network configuration. To access the
OpenCom 100 Configurator, you should also install Netscape Communicator 4.5 (or higher).
Linux
The Linux network configuration is usually performed by the set-up program with which you install a Linux distribution. After installation, you will see a series of “How To's”. In
“Linux NET-3-HowTo” and “DHCP
Mini-HowTo” you will find instructions on TCP/IP configuration.
For the OpenCom 100 to configure the TCP/IP settings of a Linux system via DHCP, you must also install the
MacOS
The TCP/IP protocol is already integrated in the new MacOS starting with version 7.6. For the
OpenCom 100 to configure the TCP/
IP settings of a MacOS system via
DHCP, you must set the configuration method to “DHCP Server” in the menu “Control Panels TCP/IP”.
To access the OpenCom 100 Config-
urator, you should also install Netscape Communicator 4.5 (or higher) or Microsoft Internet Explorer 4.5 (or higher).
Configuration Configuration for Linux and MacOS
53
Configuring the OpenCom 100
Preparing the
Configuration
Before starting with the configuration, make sure you have the following documents at hand:
■
An overview of the ports
■
A list of the terminals to be connected
■
A list of the IPEIs, if you wish to log on DECT terminals in the secure procedure
■
A list of the users to be set up
(staff entitled to use the services of the OpenCom 100) with their names, departments, and the internal call numbers you want to allocate to them
■
For Internet access: the Internet service provider access data.
Data not available for first-time configuration can be updated or corrected at a later date.
Note: Use the Configuration Guide
starting on page 111. This will assist
you in making the settings in the correct sequence.
Starting the Web Console
1. Start your Web browser. Enter the OpenCom 100 IP address in the “Address” box: http://192.168.99.254/.
If the configuration PC gets its IP address automatically from the
OpenCom 100 or if the
OpenCom 100 is entered as the domain name server, you can also start the Web console by entering the DNS name. The
DNS name in the factory setting is host.domain. You can change this in the Configurator (NET
Configuration: Easy Access
menu).
2. The OpenCom 100 Web console is started. First set the country in which you are operating the
OpenCom 100, and in which language the Web console is to be displayed.
54
Configuring the OpenCom 100 Configuration
OpenCom 105: log-on dialogue box
3. To commence configuration, you must first log on. For the initial configuration, enter your:
- user name: “Administrator”
- password: for the initial configuration, leave this box blank.
4. Confirm this by clicking on OK.
This puts all connected terminals into the “Guest” user group with restricted user rights. In this way you prevent international external calls from the terminals, for example, while you are configuring the OpenCom and the users.
Configuration Configuring the OpenCom 100
55
OpenCom 105: dialogue box for initial access
5. The software opens a dialogue for initial access. Determine an administrator password and enter it in this dialogue.
6. Confirm your input with Apply.
7. Click on the Configurator button on the home page.
You will find notes on using the Con-
figurator and in the online help.
Click on Help in the menu bar or click on TOC to activate an overview of help topics.
Loading the Online Help
The online help can now be loaded in the Configurator:
1. Go to the SYS Configuration:
Components menu. Select the entry Online Help and click on
Browse.
2. Look for one of the languagespecific ZIP files in the OLH directory of the set-up CD. Confirm your choice by clicking on Open.
3. Then click on Load to transfer the online help to the system.
56
Configuring the OpenCom 100 Configuration
Please note: After completion of
the loading operation, the system will take a few minutes to analyse the transferred file.
Note: You can downed the latest
version of the online help from http://www.detewe.de/.
Finishing the
Configuration
1. When you have completed all the settings in the Configurator, you must save the configuration
(see also Saving and Loading the
2. Then select the Log-off command in the upper menu bar.
Preconfiguration
Configuration of the OpenCom 100 can be prepared at your DeTeWe
Customer Service Centre or by an authorised DeTeWe dealer. For this purpose, a OpenCom 100 installed here is programmed with the customer data (e.g. user data, call distribution schemes, cord-bound terminals).
This data is stored and then loaded into the OpenCom 100 at the customer’s site by a service technician.
This prepared configuration must be completed at the customer’s site
(LAN configuration and DECT terminals).
For configuration of the
OpenCom 100 Internet functions, first ask the responsible system administrator for details of the customer’s LAN prerequisites.
Remote Configuration
The OpenCom 100 configuration can also be altered or updated remotely by a customer service centre or authorised dealer. This requires activation of internal RAS access in the
OpenCom 100 for the customer service centre/authorised dealer.
Note: If one or more MSNs are en-
tered on the PBX Configuration: Sys-
tem: Remote service menu page in
the Configurator and the Status op-
tion is activated, remote configuration access is then activated when a data call from one of the entered
MSNs is registered.
The customer service centre/authorised dealer can then log into the
OpenCom 100 as an administrator:
■
User name: “Administrator”
■
Password: administrator password
Note: If you do not wish to let the
customer service centre/authorised dealer know the administrator password, you can define a temporary password for remote configuration with at least five digits.
Configuration Configuring the OpenCom 100
57
Use the following code digit procedure on a standard terminal or a system telephone to activate internal remote maintenance access for the service centre/authorised dealer:
Remote configuration on (log-on with administrator password)
H * 1 9 *
Z (system PIN) #
Remote configuration on (log-on with temporary password)
H * 1 9 * Z (system PIN)
* Z (temporary password) #
Remote configuration off
H # 1 9 #
Activation is automatically cancelled 30 minutes after the last configuration activity.
Note: During remote configura-
tion, the OpenCom 100 is blocked for
RAS access by any further users.
Please note: The system PIN is
preset to “0000” and it is absolutely imperative that the system administrator changes it to prevent undesirable remote maintenance.
Using remote configuration, all
OpenCom 100 settings with the exception of the system PIN can be edited or updated. New software versions of the OpenCom 100 and the software for the connected system terminals and base stations can also be installed (see the SYS Configura-
tion: Firmware menu in the Config-
urator).
For security reasons, settings in the
Configurator, Net Configuration should only be edited on site to avoid malfunctions or failures in the customer’s LAN (e.g. due to IP address conflicts). Refer to the chapter
entitled Configuration Examples starting on page 62, where interac-
tion between the OpenCom 100 and a LAN is explained.
Codes for IP
Configuration
The IP configuration of the
OpenCom 100 is performed on the
Web console in the Configurator, in the NET Configuration: Easy Access menu.
In the event that the IP configuration of the OpenCom 100 has to be changed and access via the Web console is not possible, you can also use a code digit procedure to change these basic settings. Entry can be made from an analogue telephone, an ISDN telephone and from system telephones.
Ask your system administrator for the OpenCom 100 system PIN. The factory setting is “0000”.
58
Configuring the OpenCom 100 Configuration
Set IP address
H * 1 8 2 Z (system PIN)
* Z (www) * Z (xxx) *
Z (yyy) * Z (zzz) #
Set NET mask
H * 1 8 3 Z (system PIN)
* Z (www) * Z (xxx) *
Z (yyy) * Z (zzz) #
Restart
H * 1 8 5
Z (system PIN) #
Saving and Loading the
Configuration
Configurations are saved in a file archive and can be loaded to the
OpenCom 100 either locally from a connected configuration PC, or by remote configuration.
The following configuration and customer data can be saved and loaded again:
■
Telephony and network parameters
■
User data
■
Telephone book entries
■
LCR tables
For further information, refer to the online help documentation under the topic SYS Configuration: Data
backup.
Loading SW Updates
New versions of the system and terminal software can be loaded to the system.
New software versions of the
OpenCom 100 are loaded from the configuration PC, which accesses the
Configurator (see the SYS Configu-
ration: Firmware menu). For information on connecting a configura-
tion PC, see Brief Guide to Initial
The terminal software is part of the
OpenCom 100 software and is automatically loaded into the terminals via the OpenCom 100 if the software version in the terminal is different from the terminal software stored in the OpenCom 100.
Note: If you are operating an PBX
cascade, new system software is automatically transferred to the slave system from the master system.
For further information, refer to the online help documentation under the item SYS Configuration:
Firmware.
Configuration Configuring the OpenCom 100
59
Resetting the System
Data
You can restore the factory settings of the OpenCom 100 in the Configurator. Should this not be possible, re-
fer to the next section entitled Hard-
Please note: If this is done, all in-
dividual settings and the user data are then lost. For this reason, you should back up your configuration regularly, the best time being after every change. For details, refer to the
chapter entitled Saving and Loading the Configuration starting on page 59
and to the Web console online help.
Proceed as follows:
1. In the Configurator, call up the
SYS Configuration: Restart menu.
2. Click on Restart with Defaults.
3. Confirm this by pressing “OK” when the query dialogue box opens.
Hardware Basic Settings
Switch
The OpenCom 100 configuration can also be reset to the factory setting by means of the hardware basic settings switch.
Please note: If this is done, all
customer settings and user data will then be lost.
To reset the OpenCom 100 to its basic settings, proceed as follows:
1. Switch off the OpenCom 100 by removing the power plug.
2. Remove the cover.
3. Press the basic settings switch.
– OpenCom 105: The basic settings switch is a key switch. You press the basic settings switch by inserting a pointed object in the opening on the cover. Hold the switch down.
– OpenCom 110/120: The basic settings switch is a hook switch.
Close the switch.
You can see the positions of the respective switches in the dia-
gram entitled Positions of the
4. Replace the power plug in the mains socket. Wait about 30 seconds until the lamp on the front of the OpenCom 100 starts to flash steadily.
5. Remove the power plug from the mains socket again.
6. Open the key switch.
60
Configuring the OpenCom 100 Configuration
– OpenCom 105: Release the basic settings switch.
– OpenCom 110/120: Open the hook switch.
The system data is now reset.
7. Replace the power plug in the mains socket.
The OpenCom 100 now reboots in the default configuration. The procedure is completed when all connected system terminals show the time on their displays.
8. Log on to the Web console (see
Starting the Web Console on page 54). Configure the
OpenCom 100 (possibly by loading a saved configuration; see
Saving and Loading the Configu-
Generating Your Own
MoH Files
The OpenCom 100 comes with an internal MoH file for Music on Hold.
The OpenCom 100 product CD contains a number of MoH files with different volume levels, which you can load at a later time as necessary.
The file format for non-resident Music on Hold is *.wav. You can also save your own MoH in a *.wav file and load it into the OpenCom 100.
If you have a Windows operating system, you can use the “Sound Recorder” program to generate your own MoH file. This program is usually located in the Windows directory called “Multimedia”.
The MoH file must be coded with
8000 Hz, 8 bit mono in accordance with CCITT, A-Law. This coding is required for the OpenCom 100 and can be set in the “Sound Recorder” when you save the file under Format
(CCITT, A-Law) and Attributes (8000
Hz, 8 bit mono).
Note: If you don't have the Sound
Recorder program or the appropriate codec on your Windows operating system, you should install these components from your Windows CD.
Load your MoH file in the Web console's Configurator, in the SYS Con-
figuration: Components menu.
Note: When generating your own
MoH file, you may incur a fee for the use of non-resident melodies (e.g. a
GEMA fee in Germany or MCPS fee in the UK). The MoH files that come with your OpenCom 100 can be used free of charge.
Configuration Configuring the OpenCom 100
61
Configuration Examples
OpenCom 100 in Computer Networks
One of the outstanding features of the OpenCom 100 is the integration of telephony and computer networks. Connect the OpenCom 100 via a computer network (LAN) with suitably configured workstations, and you can use its network features from these workstations. Using a
Web browser you can access: company telephone book (if the multi-company variant is activated).
In addition, the OpenCom 100 can be used as an Internet access server.
RAS access can also be implemented using the OpenCom 100, which enables the integration of external staff in the LAN.
■ the OpenCom 100 Configurator
■ call charge administration
■ the OpenCTI 50, with which telephone functions can be used on a PC
In this chapter you will find several examples of configurations showing integration of the OpenCom 100 in a
LAN. Which example applies to your situation depends on the size and properties of the existing or planned
LAN infrastructure.
■ the OpenCom 100 central telephone book and your personal telephone book as well as to the
The following LAN prerequisites are possible:
Server configuration in the LAN OpenCom 100 Functions
No IP server present OpenCom 100 functions automatically as DHCP and
DNS server
IP server present
DHCP server present
OpenCom 100 functions automatically as DHCP client
System Administrator must assign IP address and
DNS name for OpenCom 100
IP server present
No DHCP server present
Special case when integrating the OpenCom 100 in a LAN; settings in the
“NET Configuration: Easy
Access” menu
must be coordinated with the responsible system administrator
62
OpenCom 100 in Computer Networks Configuration Examples
Introduction to TCP/IP
In a single LAN it is possible to use various protocols for the transmission of data. The connection between a workstation computer and the OpenCom 100 runs via the TCP/
IP protocol used on the Internet.
TCP/IP can be used together with other protocols (e.g. NetBEUI, Apple-
Talk or IPX/SPX) on the same network.
Every device participating in data transmission using TCP/IP requires a unique IP address. An IP address consists of four groups of digits from
0 to 255, each separated by a full stop. The supplementary protocols
DHCP and PPP automatically assign
IP addresses to devices. Class C networks normally use IP addresses in which the first three numbers are the same and the last number is uniquely assigned to a specific device in the LAN. On the Internet, unique addresses assigned by a special organisation created for this purpose are used. Within a LAN, you can use addresses which are not unique world-wide.
network mask, the connection is established via the default gateway. If a device knows several data routes to different intermediate stations, one speaks of a router.
The domain name system (DNS) resolves a plain text DNS name into an
IP address. The DNS is a hierarchically structured database, distributed worldwide. A DNS server can supply information on the names and IP addresses for which it is responsible. For all other information, a DNS server contacts other DNS servers. For the establishment of every connection from the workstation, it is possible to give either an IP address, or a name that a DNS server resolves into an IP address.
Note: For further explanations of
technical terms, refer to the Glossary on the CD-ROM supplied.
TCP/IP enables the establishment of connections via one or more intermediate stations. The decision whether to connect directly or indirectly to the partner device depends on the network mask. The network mask for a class C network is
255.255.255.0. If the IP address of the partner device does not fit the
Configuration Examples Introduction to TCP/IP
63
OpenCom 100 in a Serverless LAN
In a peer-to-peer network, the workstations are connected to one another via network cables. In many networks, the cables run in the form of a star from a central hub. Such networks do not require special servers. This configuration example is also valid for a LAN with a server using a protocol other than TCP/IP
(e.g. AppleTalk or IPX/SPX).
ISP
(DNS)
S
0
Ext.
PC
OpenCom
(DHCP, RAS, int. DNS, Internet)
S
0
Net
PC 1 PC 2
S
0
Net Hub Net
The OpenCom 100 in a serverless LAN
192.168.99.254
192.168.99.129 to 192.168.99.148
192.168.100.0 to 192.168.100.10
255.255.255.0
192.168.99.254
192.168.99.254
In a serverless LAN, the
OpenCom 100 takes over the IP configuration of the connected workstations. All TCP/IP settings necessary for the workstations are assigned by the OpenCom 100 via DHCP (dynamic host configuration protocol).
In this operating mode, an IP address space reserved for such networks is used:
OpenCom 100 IP address
DHCP addresses: IP address space for workstations
PPP addresses: IP address space for RAS dialling
Network mask (class C network)
DNS server IP address
Default gateway IP address
64
OpenCom 100 in a Serverless LAN Configuration Examples
Install the TCP/IP network protocol and a Web browser for every workstation which is to have access to the
OpenCom 100 network features.
For notes on installing network
cards, refer to Connection by Network
DNS Name Resolution
In a serverless LAN, the internal DNS name resolution is performed by the
OpenCom 100. If you type the string
“host.domain” into your browser, a
DNS request is sent to the
OpenCom 100 IP address. The
OpenCom 100 responds with the correct IP address, so that the Con-
figurator home page can be called up.
In a peer-to-peer network (Windows network), the workstations each have a name which is displayed in the network environment. These
NetBIOS names can differ from the
DNS names assigned to the workstations by the OpenCom 100. The
OpenCom 100 is not visible in the network environment.
Internet Access
If access to an ISP has been configured on the OpenCom 100, the
OpenCom 100 can be operated as an
Internet access server without any additional configuration of the workstations. When you want to see a Web page, you simply type the URL
(uniform resource locator; Internet address; “http://...”) in your browser.
In a serverless LAN, the
OpenCom 100 is configured as a DNS server and default gateway. The workstation therefore sends its Internet connection request to the
OpenCom 100.
In almost all cases, the request will contain a DNS name which is unknown in the internal network.
When you type a URL into your browser, the OpenCom 100 receives the request to find the corresponding IP address. If the name is unknown in the LAN, the request is forwarded to an ISP’s external DNS server.
Note: Workstation PCs automati-
cally add a domain name to URLs without a dot. You specify this do-
main name in the Configurator. For
example, if you have configured
“firm.co.uk” as the domain name, an access request for “www.firm.co.uk” will be interpreted as a local DNS request which does not lead to the establishment of an Internet connection. For this reason, you should choose a name which is not used in the Internet as the domain name
(“firm-opencom.co.uk” for example).
Configuration Examples OpenCom 100 in a Serverless LAN
65
RAS Access
You can establish a connection from an external computer with an ISDN card to the OpenCom 100. The necessary TCP/IP settings are transmitted by the OpenCom 100 on establishment of the connection. The computer that has dialled in now has access to all services in the LAN capable of being used via TCP/IP. The authorisation for RAS access is set up in the Configurator via the User
Manager: User Groups menu.
In a serverless LAN, Windows uses the NetBIOS protocol for accessing files and printers via the network environment. NetBIOS can use Net-
BEUI, IPX/SPX or TCP/IP as the transport protocol. In the network environment, you can only access files and printers on workstations using TCP/IP for NetBIOS.
Note: In a serverless LAN, the work-
stations running decide independently which one is to keep the list of names visible in the network environment. This process is triggered by broadcasts, which can take some time on a RAS connection. You can shorten this period by activating the “Find >
Computer” function in the Start menu and selecting the client computer.
OpenCom 100 in a LAN with an IP-enabled Server
In a LAN with an IP-enabled server, you should coordinate integration of the OpenCom 100 with the responsible network administrator. You must decide on the IP address space to be used and which network services
(DHCP, DNS, RAS, Internet access) the OpenCom 100 is to handle in the
LAN.
ISP
(DNS)
S
0
Ext.
PC
OpenCom
S
0
Net S
0
int
Server
(DHCP, RAS, int. DNS,
Internet)
S
0
Net
PC 1 PC 2
S
0
Net Hub Net
The OpenCom 100 in a LAN with an
IP-enabled server
In many cases, an IP-enabled server configures the TCP/IP settings via
66
OpenCom 100 in a LAN with an IP-enabled Server Configuration Examples
DHCP for all workstations. On starting, the OpenCom 100 requests TCP/
IP settings via DHCP. If this request is responded to, the OpenCom 100 uses the TCP/IP settings received.
You can then use a workstation to access the OpenCom 100 Configura-
tor under the IP address assigned by the server.
In networks in which the TCP/IP settings are made manually, you have to enter the corresponding TCP/IP settings in the OpenCom 100 Con-
figurator (NET Configuration: Easy
Access menu). Here the
OpenCom 100 acts as the DHCP server. A workstation requesting the
TCP/IP settings via DHCP then receives the settings you made in the
Configurator.
DNS Name Resolution
In a LAN with an IP-enabled server, the latter is also responsible for DNS name resolution. If you want to start the Configurator by entering a DNS name, you must link this name on the server with the IP address used by the OpenCom 100. For further information, refer to the server documentation.
Note: To access the OpenCom 100
under the same IP address after a restart, you must specify this IP address permanently on a DHCP server. On a
DHCP server it is possible to link the
MAC address of a network card with a specific IP address. You will find details in the server documentation.
Internet Access
You can also use the OpenCom 100 as an Internet access server in a LAN with an IP-enabled server. To do this, you must enter the OpenCom 100 IP address on the server as the default gateway. In addition, you must edit the internal DNS server configuration so that the resolution of external DNS names is forwarded to the
OpenCom 100.
In this example, the Internet connection is established from a workstation via the server, which in turn requests Internet access from the
OpenCom 100.
There are two different ways of suitably configuring the internal DNS server. You can enter the
OpenCom 100 IP address as a DNS forwarder. If you require access to extended DNS information, you can also configure the DNS server for a recursive DNS request without the
DNS forwarder. For further explanation, refer to the DNS server documentation.
Configuration Examples OpenCom 100 in a LAN with an IP-enabled Server
67
ISP
(DNS)
S
0
OpenCom
(Internet)
S
0
Net S
0
int
Server
(DHCP, RAS, int. DNS)
S
0
Net
Ext.
PC
PC 1 PC 2
S
0
Net Hub Net
The OpenCom 100 as a DNS server in a
LAN with an IP server
RAS Access
In a LAN with an IP-enabled server you can also enable external computers to dial in via the
OpenCom 100. To do this, you should coordinate with the network administrator the IP address space which can be assigned to an external computer dialling in, and enter it in the
Configurator, NET Configuration:
Easy Access menu, under PPP Ad-
dresses.
The user account administered by the OpenCom 100, with which dialling in is permitted, only allows the establishment of direct and anonymous TCP/IP connections such as
HTTP, FTP or SMTP connections. If you additionally want to allow file or printer access in the network, you must set up a suitable user account on the addressed server for network log-in. If you use the same log-in name for the OpenCom 100 user account and the same password for the network log-in, you have to enter this combination only once when dialling in.
ISP
(DNS)
S
0
OpenCom
(RAS, Internet)
S
0
Net
Server
(DHCP, int. DNS)
Net
Ext.
PC
PC 1 PC 2
S
0
Net Hub Net
RAS access by the OpenCom 100 in a
LAN with an IP server
Note: In a larger Windows network
with several segments, the lists of computer names visible in the network environment can no longer be established by broadcasts. In this case you use a special WINS server whose address the OpenCom 100 does not make known to the workstation when dialling in. For this reason, you enter the address of a WINS server manually in the network settings of the workstation.
68
OpenCom 100 in a LAN with an IP-enabled Server Configuration Examples
LAN-to-LAN Link
You can use the OpenCom 100 to interlink two LANs via ISDN. To do this, you configure two OpenCom 100 systems so that they can dial in to each other. In order for this to work, the two LANs must be configured for
OpenCom
(IP=192.168.99.254,
Net=192.168.99.0)
Net S
0 different IP address ranges (subnetworks). For at least one of the
OpenCom 100 systems, change the prescribed address range for the
LAN.
OpenCom
(IP=192.168.11.254,
Net=192.168.11.0)
S
0
Net
PC 1 PC 2 PC 1 PC 2
Net Hub Net
The OpenCom 100 in a LAN-to-LAN link
In the Configurator, NET Configura-
tion: LAN-LAN menu you can configure the dial-in settings. The
OpenCom 100 will set up a connection whenever a TCP/IP data transfer to the other LAN is requested.
Note that such a connection is only set up when specific requests are made. These can be for FTP file transfers, e-mails or downloading
Web pages. Name resolution via broadcasts is not possible. If you wish to use the LAN-to-LAN link to access files and printers in the Windows network, you need an IP-enabled server that administers the name resolution for the Windows network.
Net Hub Net
As the IP address range, you can select one of the 256 class C subnetworks designed for local LANs.
Select a class C sub-network in the range from 192.168.0.0 to
192.168.255.0.
Configuration Examples LAN-to-LAN Link
69
Useful Information on Internet Access
Costs
The OpenCom 100 uses a router function to access the Internet, which means that it automatically establishes an Internet connection when required and terminates the connection after a certain period of time if no data are being transmitted.
Unfortunately, programs other than those typically intended to access the Internet (such as your browser or your e-mail software) may send out data packets which cause an Internet connection to be established, even if these programs are not strictly Internet-associated applications.
Examples of such programs are the
Microsoft
TM
XP
TM
operating system, various multimedia programs such as Realplayer
TM
and anti-virus applications that may establish an Internet connection for automatic updates (the so-called “phone home function”).
It is therefore highly advisable to limit ISP access by specifying the maximum monthly connection time under Connection time per month
(maximal) in the NET Configura-
tion: Connections: ISP menu on the web console.
Using the Web
A Web browser not only enables you to use the OpenCom 100 Configura-
tor from every workstation but also to obtain a wealth of information from the Internet. Simply enter the desired URL in the address field of the browser. Access from a standalone PC via an online service differs from Internet access via the
OpenCom 100 in the following respects:
■
When you request a Web page, dialling in results automatically.
There is no display of dialogues with manual confirmation of dialling in or hanging up.
■
Requesting Web pages is not a connection-orientated service.
When the Web page has been loaded completely, the TCP/IP connection is cleared. If you do not request further Web pages, the OpenCom 100 automatically releases the connection to the
Internet after a certain, specifiable duration.
■
It is possible to call up Web pages simultaneously from several workstations.
■
The OpenCom 100 can block access to certain Web pages by means of filter lists.
70
Useful Information on Internet Access Configuration Examples
One of the most important services in the Internet is e-mail. E-mails are buffered in individual e-mail accounts on a mail server. Mail servers are operated by ISPs for example.
With the OpenCom 100 you can set up one or more e-mail accounts for every user account configured on the OpenCom 100. These e-mail accounts are then checked at regular intervals.
If there are new e-mails in an e-mail account, and the OpenCom 100 has been configured for this function, the user specified in the
OpenCom 100 user account is notified of the new e-mail on his system terminal. System telephones from the OpenPhone 6x and 2x product range can also display information such as the sender or the subject of the e-mail.
NAT
Network address translation (NAT) is activated on accessing the Internet
(ISP). You require this feature in order to translate internal IP addresses to valid external IP addresses. This has three important consequences for Internet access:
■
Several workstations can share a single Internet access. You do not require a LAN access, only a single account with the Internet service provider.
■
The IP addresses used in the LAN are translated into IP addresses valid worldwide. So you require no such addresses for your LAN.
■
Only TCP/IP connections triggered from a workstation can be established. Consequently, while you can call up Web pages from a workstation, you cannot install a Web server visible in the Internet on a workstation.
Certain protocols cannot be used when NAT is being used. This affects protocols with the following properties:
■
TCP/IP addresses are transported in the useful load, e.g.
NetBIOS over TCP/IP.
■
The protocol requires an active, inward-directed connection establishment, e.g. ICQ.
Configuration Examples Useful Information on Internet Access
71
■
The protocol will function without TCP/UDP port numbers, e.g.
ICMP or IGMP.
The OpenCom 100 NAT has suitable processes for ensuring the functions of many important protocols affected by these rules. These are the protocols FTP (in “active” mode), Cu-
SeeMe (“videoconferencing”), IRC
(“chat”), ICMP errors (“traceroute”) and ICMP echo (“ping”).
Protocols which require inward-directed connection establishment can be configured in the Net Config-
uration: Port Access menu. For further information, refer to the online help of this menu.
72
Useful Information on Internet Access Configuration Examples
PBX Networking
As requirements grow, the
OpenCom 100 can be operated together with other PBX installations.
If you merely need a larger number of connections, it is easy to link a
second PBX (“PBX Cascading”). If you
want to operate the OpenCom 100 at several locations with different
PBXs, this is possible by PBX Net-
PBX Cascading
You can combine two PBXs in order to increase the number of terminals that can be connected. A master PBX and a slave PBX are connected to one another by means of two cables.
The two PBXs essentially function
Master PBX
OpenCom 120 like a single PBX with a higher number of ports. The master PBX controls the slave PBX. The following
PBXs from the product family can be used for cascading:
Slave PBX
OpenCom 105, OpenCom 110,
OpenCom 120
Note: The OpenCom 107 is not
equipped with a PCM port. For this reason, PBX cascading is not possible with this PBX.
For the PBX Cascading you will need a license. The license agreement provides you with the necessary steps to activate this function
Functionality of PBX
Cascading
PBX cascading requires two twistedpair leads with RJ45 plugs between the PBXs:
■
Voice data: one lead with all eight pins wired 1 to 1. Connect this to the PCM ports of the
PBXs. The shielded CAT-5 lead may be up to three meters long.
■
Administration data: one CAT-5
Ethernet lead. You connect this
PBX Networking PBX Cascading
73
to the LAN2 port of the master system (host system) and to the
LAN1 port of the slave system
(add-on system).
PBX 1
(Master)
PBX 2
(Slave)
PCM LAN 2 LAN 1 PCM
CAT-5 Ethernet lead
Voice data lead (eight pins assigned, joined 1 to 1)
Cascaded PBX system
Putting a Cascaded PBX into Operation
Proceed as follows to put a cascaded
PBX system into operation:
1. Take the additional slave system out of its packaging and place it in immediate proximity to the master system. Connect a system telephone to the slave system for a later performance check. Use the U pn
1 press-fit terminal.
Please note: If you wish to use
an older PBX as the slave system, you must first load system software for it
(version 3.0 or higher).
2. Back up the master system data.
For further information, refer to the online help topic SYS Con-
figuration: Data Backup.
3. Switch off the master system if it is operating. Disconnect the module from the power supply by pulling out the mains plug.
4. Connect the two modules by means of two suitable cables as described above.
5. Power on the two PBXs. The order in which you do this does not matter.
6. Select the Type of slave system with the Configurator of the master system in the
SYS Configuration: System:
Slave dialogue box. Enter the
Ethernet card address of the slave system in the MAC address input field.
If a possible slave system was detected when the system was started, there is an additional entry in the Type field (“Online:
PBX type”). If you select this entry, the settings for Type and
MAC address are applied automatically.
Note: There are two versions of the
OpenCom 105. If you select the ap-
propriate entry under Type, the corre-
sponding module version will be dis-
played under PBX Configuration:
Ports.
Please note: If you change the
type of slave system later on, the port settings that have been made will be deleted.
74
PBX Cascading PBX Networking
The master system then initialises the slave system. This may involve transfer of firmware (operating software) from the master system to the slave system.
This can take a few minutes.
7. Configure the system telephone connected to the slave system for testing purposes in the Con-
figurator. In the
PBX Configuration: Ports: Upn dialogue, click on one of the additionally displayed entries of the type Upn 1/n (1: slave system, n: U pn
port number).
Note: Changes to the configura-
tion while initialising the slave system may trigger error reports referring to the ongoing initialisation.
You can see that the initialisation has been completed from the display on the system telephone connected to the slave system.
Notes
Observe the following when operating a cascaded PBX system:
■
All U pn
, S
0
and a/b ports of the slave system can be used with appropriate telephones. All features of system telephones on
U pn
ports are available without restriction.
■
The S
0
ports of the slave system can also be used for trunk lines
or for PBX networking (see PBX
Networking starting on page 76).
■
It is not possible to operate a
DECT base station on one of the
U pn
ports of the slave system.
■
The COM, actor/sensor and –if present– LAN2 ports of the slave system cannot be used.
■
The two communications systems must have a direct Ethernet connection or be connected via a hub in order to exchange data. They cannot be connected through a router.
■
The slave system cannot be addressed directly through a LAN.
For configuration, always use the Web console of the master system.
■
A memory card installed in the slave system (OpenVoice, Open-
Attendant) cannot be used.
■
To operate the slave system again normally, you must reset it to its factory settings (refer to
Resetting the System Data starting on page 60).
PBX Networking PBX Cascading
75
PBX Networking
In Release 3 of the system software,
OpenCom 100 provides all the features necessary for PBX networking.
You need PBX networking in the following cases:
■
To operate the OpenCom 100 as a subsidiary system on another
PBX. This will also allow you to use the OpenCom 100 as a DECT server, for example.
■
To network the OpenCom 100 with an OpenCom 1000. In this way you can use the
OpenCom 100 as a PBX for a branch office, for instance.
■
To network several
OpenCom 100s into a PBX system.
■
To use flexible configuration possibilities of trunk lines for a
OpenCom 100.
All settings that affect the configuration of PBX networking can be found in the Configurator menu
PBX Configuration: Trunks and in the PBX Configuration: System:
Settings dialogue under System
linking. Refer also refer to the corresponding help topics in the
OpenCom 100 online help.
Note: If you do not need the fea-
tures of PBX networking, the simplified configuration is sufficient in most cases. For this purpose, assign the
preconfigured trunk groups Multi-
terminal access or System access to
the ports. The preconfigured route
called External trunk now makes it
possible to seize an external line immediately or by first dialling the prefix “0”. You can rename the preconfigured bundle and the preconfigured route if required, but you cannot delete them.
Connections
Networking two or more PBXs means interconnecting them. The
OpenCom 100 allows you to use both trunk lines and point-to-point connections on external S
0
ports or on the S
2M
port.
PBX PBX PBX PBX
PBX
Example of a PBX network
Trunk line
Point-to-point connection
Various line types and transmission protocols can be used for point-topoint connections. The required network topology (distance, connection capacity) determines which type of point-to-point connection is most suitable.
76
PBX Networking PBX Networking
Protocol: Q.SIG or DSS1
The Q.SIG protocol, designed for
ISDN point-to-point connections, is the preferable choice as the transmission protocol; alternatively, the
DSS1 protocol, designed for ISDN dial-up connections in the Euro-
ISDN, can be used. Certain PBX networking features can only be used with the Q.SIG protocol, however. In particular, the identifier indicating whether a call is internal or external cannot be transmitted using DSS1.
Both protocols implement communication on several protocol layers:
■
L1: Layer 1 defines the physical line properties and the electrical coding of signals.
■
L2: Layer 2 enables communication via individual error-protected channels that are independent of each other.
■
L3: Layer 3 defines the administration of the individual channels and implements the features designed for ISDN.
Master/Slave
For an ISDN connection, it is possible to determine which PBX is the protocol master and which the protocol slave. This relationship can be determined for all three protocol layers independently of one another.
For each protocol layer, the PBX at the other end always has to be suitably configured. If one PBX is the protocol master for a layer, the other
PBX must be the protocol slave for this same layer. Normally all three protocol layers are configured identically. In the case of a trunk line, the network operator is the protocol master for all three layers.
Note: In the case of an S
2M
line, it is also possible to determine for each useful channel which end can administer a channel (master = internally seized or slave = externally seized).
On S
0
lines this setting is determined by “L3 master” for both B-channels.
L1 Clock
To enable PBXs in the ISDN network to communicate with each other, they must be “clock-aligned”. The L1 protocol master sets the clock for layer 1, and the L1 protocol slave adopts (synchronises to) this clock.
When planning a PBX networking scheme, you must make sure that the L1 clock propagates from a master via a number of PBXs.
Network operator
M S
PBX1
M
M
S
PBX 3
S
S
PBX 2
M
Trunk line
Point-to-point connection
Example: propagation of the L1 clock
If more than one port with the setting L1 Type = “Slave” is configured on an OpenCom 100 and the setting
PBX Networking PBX Networking
77
L1 sync possible has been activated, then one of the ports is automatically defined as the L1 clock source.
The OpenCom 100 will automatically switch the clock source to another port configured as an L1 clock source
(if a line fails, for example).
Please note: Reciprocal or circu-
lar application of the L1 clock is not allowed.
Example: In the above case you could reverse the L1 slave/master setting for the connection between
PBX 1 and PBX 3. However, if you then activate the setting
L1 sync possible for the port of PBX
1, this may cause parts of the PBX network to stop functioning temporarily.
When applying the L1 clock of trunk lines, you can assume that the public network is “clock-aligned”. So, in the above example, you can connect additional trunk lines to one of the
PBXs.
Types of Point-to-Point
Connection
There are different types of connection available for an ISDN point-topoint connection between two PBXs, depending on the distance between them.
Direct Connection
This type of point-to-point connection joins the two systems directly to each other using a crossover twisted-pair cable. An S
0
connection can be used for distances up to 1,000 metres, while an S
2M
connection can span up to 250 meters. Normally one
PBX is the protocol master for all three layers, and the other PBX is the protocol slave for all three layers.
PBX 1
L1 master
L2 master
L3 master
Direct connection
PBX 2
L1 slave
L2 slave
L3 slave
■
Use the RJ45 jacks on one of the external S
0
ports for an S
0
connection between two
OpenCom 100s.
■
Use the pressure terminal of the
S
2M
port for an S
2M
connection between two OpenCom 120 systems.
PBX 1, S
0
ext
1 2 3 4 5 6 7 8
PBX 1, S
2M
Rx+ Rx- Tx+ Tx-
8 7 6 5 4 3 2 1
PBX 2, S
0
ext
(RJ-45 socket)
Rx+ Rx- Tx+ Tx-
PBX 2, S
2M
(Pressure clamps)
Wiring of a direct connection
78
PBX Networking PBX Networking
Connection via an Active
Transmission System
For distances exceeding the range of a direct connection, an active transmission system can increase the range to up to 50 km. Normally the
L1 master is the transmission system for the two connected PBXs. For the protocol layers L2 and L3, one PBX is normally the protocol master and the other PBX is the protocol slave.
PBX 1
L1 slave
L2 master
L3 master
Transmission
System
L1 master
PBX 2
L1 slave
L2 slave
L3 slave
Connection by an active transmission system
Note: The active transmission sys-
tem itself gets its L1 clock either from the network operator or from a clock generator connected by wire.
Connection via the Public
Network
Point-to-point connections via the public network of a network operator can be used for bridging distances beyond 50 km. Due to the long distance involved, for technical reasons it is not possible to synchronise the L2 protocol. Consequently, the public network is normally the protocol master for protocol layers
L1 and L2. One PBX is therefore the
L3 master and the other PBX the L3 slave.
PBX 1
L1 slave
L2 slave
L3 master
Public network
L1 master
L2 master
PBX 2
L1 slave
L2 slave
L3 slave
Point-to-point connection via a public network
Configuration
The possible configurations described below can be set up in the
Web console using the PBX Configu-
ration: Trunks menu.
Trunk groups
This is a group of lines of the same type and direction. A line can only be assigned to one trunk group.
Network operator
PBX 1 PBX 3
A E
B
C
D
PBX 2
Bundle
Trunk line
Point-to-point connection
Example of a PBX network with trunk groups
In the above example, the following trunk groups are configured for
PBX 1:
■
Two S
0
lines in a multi-terminal configuration to the network operator which are assigned to the “A” trunk group.
■
Two S
0
point-to-point connections to PBX 2 which are assigned to the “C” trunk group.
PBX Networking PBX Networking
79
■
One S
0
point-to-point connection to PBX 3 which is assigned to the “E” trunk group.
Note: A line or a trunk group can-
not be seized directly. It is always performed indirectly via a route.
Routes
A route is a group of trunk groups enabling a connection in one direction. If the first trunk group of a route is fully utilized, the next trunk group is seized (“trunk group overflow”). One trunk group can also be used for different routes.
In the above example, a route set up for PBX 1 allows a connection to
PBX 2. Trunk groups “C,” “E” and “A” are assigned to this route. If a user connected to PBX 1 wants to reach a party in PBX 2, lines will be seized in the following order:
■
PBX 1 first searches for a free channel in the “C” trunk group.
■
If all the lines in trunk group “C” are busy, the system tries to set up a connection via trunk group
“E”. PBX 3 switches the connection through, provided it is appropriately configured (refer to
Numbering starting on page 80).
■
If it was not possible to set up an indirect connection via PBX 3, the system tries again via trunk group “A”. The “prefix” necessary for this can be configured with the route.
■
The user does not get a busy signal until the attempt to set up an indirect connection via the network operator has also failed.
Note: If an internal connection is
switched via a network operator, the call is signalled using the external number of the calling PBX.
For each route you can define a randomly selectable code digit for seizing the route. You can also configure whether a user is authorised to seize a particular route, whether LCR is to be used for one of the trunk groups and the criteria (business or private call, booking numbers) for evaluating call data.
Numbering
A user can seize a particular route by pre-dialling a specific code digit.
With this “open numbering”, a user must always dial this code digit and then the telephone number in order to reach a party in another PBX.
If none of the telephone numbers in your PBX network occur twice, you can also configure “closed numbering”, allowing the same telephone number to be used for reaching each user within the PBX network.
With closed numbering, the
OpenCom 100 determines which route to seize from the telephone
80
PBX Networking PBX Networking
number dialled. The information needed for routing a call can be configured in a numbering table containing up to 100 entries. You use this table to assign telephone numbers and/or ranges of telephone numbers to a particular route.
A default entry in the numbering table makes it possible to seize a “default route” for all remaining unassigned numbers. In particular, this simplifies configuration of the
OpenCom 100 as a subsidiary system: the only entry you assign to the
default entry is the route to the host system
PBX
100-199 c d a b
PBX
400-499
4: b
D: c
D: a
PBX
200-299 e g h
3: e
5: h
D: d f
PBX
500-599 i
PBX
300-399 k
3: i
D: g
5: k
D: f
D:Default
Route
Example of closed numbering tables
The automatic switching of call requests (i.e. routing) by means of trunk group overflow or default numbering can lead to “circular switching”.
To avoid this, a “transit” counter is incremented whenever a connection is switched through on Q.SIG lines.
When the configured maximum value is reached, further switching stops.
Technical Details
A different PBX number must be set for each OpenCom 100 in a PBX network. This setting can be found in the Web console, in the menu
PBX Configuration: System under the heading System linking. You can also set the maximum value for the transit counter there. This value depends on the topology of the PBX network and should allow the system to have the maximum number of further connections possible.
You can display the connection status of the lines at any time in the
Configurator menu System info:
PBX: Trunks. You should check this in particular after making changes to a configuration to see whether all the lines used for system networking are operable.
Some of the features possible in
Q.SIG are not supported by
OpenCom 100 with all their options, for example callback on busy within the Q.SIG network. The call categories defined in Q.SIG (e.g. Emergency
Call, Operator, Normal) and the Q.SIG name transmission feature (“user names”) are fully supported.
The code digits to be used for seizing a route with open numbering are not transmitted to the destination
PBX and thus cannot be evaluated by it. To reseize a route (for example for a callback), you must set the appropriate digit prefixes in the trunk
PBX Networking PBX Networking
81
group configuration for the routes to be reseized.
Tip: If, for example, you are configuring a route which can be seized using routing code “5” and have selected one or more bundles for this route, change the Prefix for dest.
call number at incoming internal setting to “5” for this bundle in order to enable the route to be reseized.
OpenCom 105
OpenCom 110
OpenCom 120
S
0
1
S
S
M/S
S
0
2
M/S
S
M/S
S
0
3
M/S
M/S
M/S
Owing to their hardware properties, not all S
0
ports of the OpenCom 100 can be used for PBX networking without restrictions. Depending on the type of system, some ports can only operate in the L1 master mode or L1 slave mode. The external S
0 and S
2M
ports can be set according to the following table.
S
0
4
M
M/S
M/S
S
0
5
–
M
M/S
S
0
6
–
–
M/S
S
2M
–
–
M/S
Legend
S = Slave
M/S = Master/Slave
M = Master
82
PBX Networking PBX Networking
Licensing Information
A licence is required for certain additional OpenCom 100 program packages, for example for the internal voice-mail system called OpenVoice.
The following information is for customers who have already obtained licences for an OpenCom 100 and would like to cascade or network their existing system with another
OpenCom 100.
In this case, new activation keys for the use of additional program packages must be generated on the
DeTeWe licence server
(http://lizenz.detewe.de).
The licensing confirmation for the cascading contains all the information you need to carry out this procedure.
PBX Networking
If you network two OpenCom 100 systems with each other, you needn't generate any new activation keys but can continue to use the corresponding functions on the existing
OpenCom 100. The “disadvantage” of this alternative is that you have to administer a separate configuration on each OpenCom 100.
Note: You will need the serial num-
bers of both infocom systems for
porting the activation keys. The se-
rial numbers can be found in the
Web console's Configurator, in the
System Info: Versions menu.
PBX Cascading
In the case of PBX cascading, the master system administers the overall configuration. For PBX cascading you need at least one OpenCom 120 as a master system, to which another OpenCom 100 can be connected as an interface expansion.
If you have already installed activation keys on an existing
OpenCom 100, they have to be ported to the master system
(OpenCom 120).
PBX Networking Licensing Information
83
Team Functions
Introduction
With the team functions you can manage your telephone communication tasks by assigning lines with separate call numbers to the keys of different terminals. The terminal users, or team members, can thus pick up one another’s calls or telephone each other using the configured keys.
Team functions can only be configured on the corded system telephones of the OpenPhone 6x product line because only these have the required features.
Explanation of Keys
The team functions are programmed on the call keys of the OpenPhone 6x telephones. Depending on the terminal, different numbers of call keys are available:
Number of available call-keys
Telephone Number of keys
OpenPhone 61 One key with a display, five keys without a display
OpenPhone 63 Three keys with a display, five keys without a display
OpenPhone 65 19 keys with a display: nine on the telephone itself and 10 on an add-on
Note: Only one function or call
number can be programmed for each call key.
The following keys can be used:
■
Trunk key: Calls (for the programmed call number, e.g. 11) are signalled to this key, and you can make internal and external calls via this number. A trunk key can be programmed with a substitute function (with another team member acting as the substitute). Calls for you are then signalled to the terminal of another team member. A trunk key also provides functions for man-
84
Introduction Team Functions
aging calls. For example, you can configure call protection if you do not want to be disturbed, or call diversion to another telephone.
■
Team key: As with a trunk key, a team key can be used to receive or make calls. However, this key cannot be used to change the settings for managing calls; it is not possible, for example, to configure call diversion to another telephone. Calls made via a team key are signalled to all terminals with a trunk key that has been programmed with the same number. For example, the team key with the number 11 calls all trunk keys with the number 11.
■
Busy key: The purpose of a busy key is to make the busy status of other team members visible. An incoming call for a busy team member is signalled on the other team member's busy key.
That team member can take this call by pressing the busy key, which seizes his own terminal's trunk key. Calls taken via the busy key are not entered in the call list of the team member who was originally called. In addition, it is possible to call the respective team member via his busy key when his terminal is idle. You set up a call to this team member by pressing your own trunk key.
■
Direct call key: Only outgoing calls can be made with a direct call key; they are signalled to all terminals with the same number programmed to a trunk key.
Calls via a direct call key are signalled to the destination terminal even if that terminal has been programmed with a substitution function or call protection. If the destination terminal has been configured for call diversion, the direct call is not diverted.
Which key is suitable for which purpose?
■
Trunk keys can be assigned call numbers for managing central communication tasks, for example, customer support. If the call numbers of the support department are assigned to trunk keys on all of its terminals, then all members of the support department can receive and manage calls and use the substitute function.
■
Team keys, for example, can be used to create a project group within a department. Calls from customers of this group can then be answered by any team member who is not busy. The team members can call each other by the team keys.
■
A busy key can be used to configure an attendant terminal
Team Functions Introduction
85
showing the status of the individual users. The attendant terminal sees the status of the users and can put calls through by simply pressing the key.
■
Direct call keys, for example, can be configured at a terminal in a conference room in order to call the secretary.
Team Configuration
You can create teams and program call keys in the Configurator of the
OpenCom 100 (PBX Configuration:
Groups and Ports: Upn menu).
Call key 1 is preset as a trunk key on all system telephones. This setting can be changed by the system administrator.
Examples of Use
The following examples illustrate the various uses of teams and team functions.
For information on the display texts and how to use the individual functions, refer to the chapter “Managing Calls in a Team” in the “Open-
Phone 61, 63, 65” user guide.
Executive/Secretary
Team
In this example, the executive/secretary team comprises two members: the executive and the secretary. The secretary has one OpenPhone 63 system telephone, and the executive has two, one of which is used as a parallel telephone in a sofa suite.
11
10
Secretary
TrK 11: Secretary
TrK 10: Executive
DK 10: Executive
Executive
TrK 10: Executive
TrK 11: Secretary
TrK 12: Private
12
Executive´s Parallel
TrK 10: Executive
TrK 12: Private
Example: executive/secretary team
Line Seizure
The secretary can be reached on the call number 11 (trunk key TrK 11: secretary’s office).
The executive can be reached on the call number 10 (trunk key TrK 10: executive’s office). He can also answer calls from his parallel telephone. In
86
Examples of Use Team Functions
addition, a private line is configured for both of the executive’s telephones (trunk key TrK 12: private).
Call numbers 11 and 10 are both configured as a trunk key on the executive’s and the secretary’s terminal respectively. Thus the executive and the secretary can use either call number (for answering as well as making calls). Each can act as a substitute for the other.
The secretary’s terminal also has the executive’s call number configured as a direct call number (DK 10: executive’s office). The secretary can therefore reach the executive and put through calls even if the executive has programmed a substitute.
Line Busy Indication
If a line is busy, e.g. TrK 11 secretary’s office, the other terminal will indicate this. The executive’s private calls via TrK 12 are not indicated on the secretary’s terminal since no appropriate trunk key is configured on the latter’s telephone.
Call Signalling
In this configuration example, calls to one’s own call number are signalled acoustically on the following telephones:
■
Call number 11 on the secretary’s telephone
■
Call numbers 10 and 12 on the executive’s telephone.
Calls for the other team member’s call number are indicated by an optical signal on one’s own telephone
(flashing trunk key LED).
The parallel telephone will indicate calls only by an optical signal.
Time-delayed acoustic signalling can be configured for TrK 10 on the secretary’s telephone. If the executive, for example, does not answer a call within 10 seconds, the secretary’s telephone will start to ring.
If the executive activates a substitute function with the secretary as the substitute, calls for call number
10 will be indicated on the executive’s telephone by an optical signal only, but signalled acoustically on the secretary’s telephone. The secretary can also activate a substitute function. Calls for call number 11 are then signalled acoustically on the executive’s telephone, and indicated by an optical signal on the parallel telephone and the secretary’s telephone.
Three-member Team
The three-member team described here is an example of a team configuration within a project group, e.g. export sales.
Each team member has one Open-
Phone 63 system telephone with all
Team Functions Examples of Use
87
call keys programmed as trunk and team keys.
10
11
Miller
TrK 10: Miller
TK 11: Johnson
TK 12: Smith
Johnson
Trk 11: Johnson
TK 10: Miller
TK 12: Smith
12
Smith
TrK 12: Smith
TK 10: Miller
TK 11: Johnson
Example: three-member team
Line Seizure
Each team member’s call number, e.g. call number 10 for Miller, is programmed as a trunk key on his telephone.
On the other telephones in the team, this call number is programmed as a team key (e.g. TK 10 on Johnson’s and Smith’s telephones). The team members can thus see which number a call is for and can answer it by pressing the appropriate team key.
The team members can call each other via the team keys. For example, Miller can call number 12 by pressing TK 12; the call is then signalled to Smith’s telephone on
TrK 12.
Line Busy Indication
If a line is busy, e.g. TrK 11 Johnson, the team keys 11 on Miller’s and
Smith’s telephones will indicate this.
Call Signalling
In this example, calls via the trunk keys are signalled acoustically. Calls via the team keys are indicated by a visual signal (the team key LED flashes).
Unified Team
The unified team described here is an example of a team configuration within a department in which calls are to be managed quickly (e.g. support department).
Each team member has one Open-
Phone 63 system telephone with all call keys programmed as trunk keys.
Miller
TrK 10: Support 1
TrK 11: Support 2
TrK 12: Support 3
10
11
Johnson
TrK 10: Support 1
TrK 11: Support 2
TrK 12: Support 3
12
Smith
TrK 10: Support 1
TrK 11: Support 2
TrK 12: Support 3
Example: unified team
88
Examples of Use Team Functions
Line Seizure
Call numbers 10, 11 and 12 are programmed as trunk keys on each team member’s telephone (TrK 10 to TrK 12.
All team members can use these numbers for answering as well as making calls.
Tip: In this team configuration it is useful to program one of the function keys on each telephone with the
“Hold” function. A call, e.g. for
TrK 11, can then be put on hold by pressing the function key. If another team member then presses trunk key TrK 11 on his telephone, he can accept the call. For further information on function keys, refer to the
“OpenPhone 61, 63, 65” user guide.
Line Busy Indication
If a line is busy, e.g. TrK 11 Johnson, the trunk keys on the other team telephones will indicate this.
Call Signalling
In this example, calls via all trunk keys are signalled acoustically.
Toggle Team
The toggle team described here illustrates how a large number of call numbers can be managed efficiently with the help of team functions.
10
11
12
13
14
15
16
Each team member has one
OpenPhone 65 with all call keys programmed as trunk and team keys.
Miller 14:22
Mi .
14.Feb
.
01
TrK 10: Support 1
TrK 11: Support 2
TrK 12: Support 3
TrK 13: Support 4
TrK 14: Support 5
TrK 15: Hotline 1
TrK 16: Hotline 2
TK 20: Support 6
TK 25: Hotline 3
23
24
25
26
20
21
22
Johnson 14:22
Mi .
14.Feb
.
01
TrK 20: Support 6
TrK 21: Support 7
TrK 22: Support 8
TrK 23: Support 9
TrK 24: Support 10
TrK 25: Hotline 3
TrK 26: Hotline 4
TK 10: Support 1
TK 15: Hotline 1
Example: toggle team
Line Seizure
Each team member is assigned seven call numbers, each programmed as a trunk key (TrK 10 to
TrK 16 and TrK 20 to TrK 26). For each member, these trunk keys are programmed either as support numbers or hotline numbers.
The first support number and the first hotline number of each team member is programmed as a team key on the other member’s tele-
Team Functions Examples of Use
89
phone, e.g. TrK 10 and TrK 15 on
Miller’s telephone as TK 10 and TK 15 on Johnson’s telephone. The assumption here is that most calls will go to the respective first call numbers, and team members can thus help each other out by answering one another’s calls.
On each telephone it is possible to toggle between the calls on individual lines, e.g. TrK 10 and TrK 11, by pressing the appropriate key (toggling).
Every call on a trunk key can be transferred to any other party by means of the R key. For more information, refer to the chapter entitled
“Consultation, Toggling, Transfer and Conference” in the “OpenPhone
61, 63, 65” user guide.
Line Busy Indication
If a line is busy, e.g. TrK 10 on Miller’s telephone, the appropriate team key will indicate this, e.g. TK 10 on Johnson’s telephone.
Call Signalling
In this example, calls via trunk keys are signalled acoustically. Calls via team keys are indicated by a visual signal (the team key LED flashes).
90
Examples of Use Team Functions
Call Queue
Introduction
A queue can be activated for the telephone numbers of any type of telephone, i.e. for system, analogue,
ISDN and DECT telephones.
If a call number with a queue is busy, calls to this number enter the queue.
A caller in the queue hears an idle tone.
Calls which remain in the queue for too long are cleared from the queue.
The caller then gets a busy tone. The time until an external call is cleared from a queue is defined by the network operator. In Germany this is usually two minutes and in other European countries usually three minutes.
If more than one telephone number
(e.g. trunk or team keys) has been configured for a telephone, separate queues are used for each number.
On the OpenPhone 65 system telephone, additional calls are signalled by a brief tone in the loudspeaker and in the display. If calls are in the queue, a number at the beginning of the second line of the display on the
OpenPhone 65 indicates how full the queue is. If more than one telephone number with a queue is configured on the telephone, the total number of entries are displayed.
Calls in a queue are handled by the
OpenCom 100 in the following order of priority: instant connection, sensor calls, automatic recalls, VIP calls, then other internal and external calls. Sensor calls thus have priority over other calls, for example. Calls of the same priority level are switched in the order of their arrival.
The system administrator sets the number of calls that can be placed in a queue individually for each user group. The value can lie between “0” and “99”. The “0” value deactivates the ”Call queue” function for a user group. When the maximum number of calls in the queue is reached, further callers hear a busy tone.
Only calls which have a “voice” service indicator are administered in a queue.
Note: As calling fax machines of-
ten operate with the “voice” service indicator (e.g. on analogue ports), you should assign ports for fax machines on the OpenCom 100 to a user
group without a queue.
Call Queue Introduction
91
Queues can be combined with the
“forwarding,” “pickup” and “hunt group” functions, for example, in order to configure an attendant terminal for an operator.
Activation of Queues
Queues can be activated per user group. The default factory setting of queues for the preset groups “Administrators” and “Guests” is off.
When using queues, it often makes sense to activate call waiting protection. For this purpose, “Call waiting protection” authorisation must be allocated to the user group, and call waiting protection must be activated on the terminal.
You should configure a new user group (e.g. “Operators”) and activate the authorisations “Call queue”, “Call waiting protection” and, if necessary, “Call forwarding”. If users belong to this group, a queue will be activated automatically for all telephone numbers assigned to them.
Call Forwarding
Forwarded calls of the forwarding type “Immediately” and “On busy” have priority over queues. The queue of the forwarding telephone is not used for forwarding calls in this manner.
During the configuration of this type of call forwarding, the contents of the queue are not transferred to the target terminal. If there are still calls in the queue when the call forwarding function is activated, these calls can only be accepted on the source terminal.
If a call is to be forwarded “After delay”, it enters the queue. If the call has not been answered before the delay period expires, it will be forwarded to the target terminal and can then be answered there.
Pickup
The functions “Pickup” (from a pickup group) and “Pickup selective” can be used together with queues.
A user who accepts a call using
“Pickup” or “Pickup selective” picks up the next call from the queue.
Hunt Groups
Hunt groups of the “parallel” type are usually used together with queues, with the queues of each telephone in the group being synchronised to each other. When a call to the number of the hunt group arrives, the call enters all parallel queues. If a call from one of the queues is answered, it is removed from all other parallel queues.
92
Introduction Call Queue
Examples of Use
Attendant Terminal for an
Operator with Two
System Telephones
The operator switches all incoming calls and can either work on the
OpenPhone 65 or the mobile terminal, the OpenPhone 25/27.
Configuration
■
Configure the system access or access for multiple terminals under PBX Configuration: Ports:
S
0
.
■
Configure the OpenPhone 65 and the RFP 21/23 under PBX
Configuration: Ports: U pn
.
■
Configure a trunk key for the
OpenPhone 65 under PBX Con-
figuration: System telephones.
■
Configure the OpenPhone 25/27 under PBX Configuration:
Ports: DECT-PP and assign the
OpenPhone 25/27 its own telephone number. Check in the
OpenPhone 25/27.
■
Under PBX Configuration: Call
Distribution: Incoming route all incoming calls to the number of the OpenPhone 65 trunk key.
■
In the Configurator, create a new group called “Operators” under User Manager: User
groups. Activate “Call queue”,
“Call waiting protection” and
“Call forwarding” for this group and set the Dial out: External option appropriately.
■
Create a user called “Operator 1” under User Manager: User. Assign this user to the “Operators” user group. Assign the telephone numbers of the
OpenPhone 65 trunk key and the number of the mobile
OpenPhone 25/27 to this user.
■
Activate Call wait. prot.
(call waiting protection) on both terminals in the Protection menu.
■
Configure a function key on the
OpenPhone 65 which activates/ deactivates a “call forwarding immediately” to the telephone number of the mobile
OpenPhone 25/27 (in the menu
Call forwarding: Divert
phone: Immediately).
Use
Incoming calls are routed to the
OpenPhone 65 manned by the operator, who then puts the calls through. A queue is used so that callers do not get a busy signal. The display on the OpenPhone 65 indicates
Call Queue Examples of Use
93
how many calls there are in the queue.
If the operator wants to leave the workstation and take along the attendant terminal, call forwarding to the OpenPhone 25/27 is activated by pressing a function key. Calls which are in the OpenPhone 65 queue must still be answered on this telephone. New calls are signalled on the mobile OpenPhone 25/27 or enter its queue, allowing the
OpenPhone 25/27 to be used as a mobile attendant terminal.
On returning to the workstation, the operator deactivates call forwarding by pressing a function key. Calls which are already in the queue are switched on the mobile
OpenPhone 25/27. New calls are signalled on the OpenPhone 65 or enter its queue.
Group of Three Attendant
Terminals
The attendant terminals switch all incoming calls. Incoming calls are administered in queues. Depending on the number of arriving calls, one to three attendant terminals in this group are manned. The attendant terminals are each equipped with an
OpenPhone 65.
Configuration
■
Configure the system access or access for multiple terminals under PBX Configuration: Ports:
S
0
.
■
Configure the three
OpenPhone 65 telephones under PBX Configuration: Ports:
U pn
.
■
Configure a trunk key with its own telephone number for each of the OpenPhone 65 telephones under PBX Configura-
tion: System telephones.
■
Configure a hunt group of the
“parallel” type under PBX Con-
figuration: Groups: Hunt
Group, and include the three telephone numbers of the trunk keys in this hunt group.
■
Under PBX Configuration: Call
Distribution: Incoming route all incoming calls to the number of the hunt group.
■
In the Configurator, create a new group called “Operators” under User Manager: User
groups. Activate “Call queue” and “Call waiting protection” for this group.
■
In the User Manager, configure a user for each of the three operators and assign these settings to the user group called “Opera-
94
Examples of Use Call Queue
tors”. Allocate each user the telephone number of the trunk key of their system telephone.
■
Activate Call wait. prot.
(call waiting protection) on all three terminals in the
Protection menu.
■
Program a function key with the function “Sign on/sign off from hunt group” on the three system telephones (in the menu
Calls: Hunt group).
Use
Incoming calls are signalled in parallel to all signed-on attendant terminals. If the attendant terminals are busy, the incoming call joins the queue on each of the terminals in the hunt group. If one of the attendant terminals accepts a call from the queue, the call is removed from the queues of all the other attendant terminals. The display on each attendant terminal (OpenPhone 65) indicates how full the queue is.
If attendants leave the terminal, they sign off from the hunt group by means of a function key. In contrast to Example 1, further calls do not have to be processed after the signoff, as the calls are also registered in the queues of the other signed-on attendant terminals.
Note: The last attendant terminal
remaining in the hunt group should not sign off, so that incoming calls can always be signalled to at least one terminal.
Call Queue Examples of Use
95
96
Multi-Company Variant
Communications systems are frequently shared by several companies. These companies want to jointly use the existing infrastructure
(e.g. the existing lines and features of the system), while at the same time they wish to organise and pay for their communication completely independently of one another.
This “multi-company variant” can be implemented using the
OpenCom 100 within a shared office, for example.
In the multi-company variant, the companies are essentially completely independent of one another.
This allows them to have their own trunk lines, which is useful for billing purposes. The OpenCom 100 hardware and software are used equally by all the companies, however. It is possible to configure the
OpenCom 100 for each company and define the extent to which the features of the system may be used.
In brief, the features of the multicompany variant are as follows:
■
Up to five companies can be configured at the same time.
■
Every user of the OpenCom 100 is assigned to a company.
■
Each available trunk group is uniquely assigned to a company so that incoming external calls can be transferred to the correct internal subscriber.
■
For each company, every route can have its own code. For example, it is possible to activate different routes with the code
“0” for different companies. This enables separate charging for outgoing external calls, for example.
■
An individual exchange (“operator”) can be set up for each company.
■
Each company can maintain the communication data of its business partners in its own company telephone book.
■
The charges can be billed individually for each company.
Multi-Company Variant
Configuring the Multi-Company Variant
The multi-company variant can be commissioned and configured by the system administrator of the
OpenCom 100 without any major effort. In the multi-company variant, the communications system behaves in exactly the same way as the single-company variant. This is particularly of interest to users who want to expand their own system and at the same time operate it in a group.
The process in brief:
5. In the case of outgoing external calls, the lines via which the members of a company can make a call must be defined (see
Allocating Routing Codes starting on page 99).
6. An exchange must be set up for each company so that the
OpenCom 100 can correctly process statuses in which a call should be routed to the ex-
Company Exchange starting on page 99).
1. The feature must be activated
(see Activating the Multi-Com-
pany Variant starting on page 97).
Activating the Multi-
Company Variant
2. The required companies must be
set up (see Configuring and Man-
aging Companies starting on page 98).
3. The users of the OpenCom 100 are assigned to the individual
companies (see Assigning Users starting on page 98).
4. In order that the OpenCom 100 can transfer incoming calls to the corresponding company (or its staff) correctly, the existing trunk groups must be uniquely assigned to the companies (see
Assigning Trunk Groups starting on page 99).
To be able to configure several companies in the OpenCom 100, the
“Multi-company variant”
(OpenCompany 45) program package must first be activated. This is done in the Configurator on the
Web console in the
SYS Configuration: Licences menu.
The licence confirmation you received with the program package contains all the information you require about how to proceed.
Only when this package has been activated are the fields required to configure the multi-company variant available in the other menus of the Web console, for example in the
User Manager: User groups menu
Multi-Company Variant Configuring the Multi-Company Variant
97
or in the PBX Configuration:
Trunks menu.
Configuring and Managing
Companies
Up to five companies can be configured in the OpenCom 100. By default, one company with the name
“Company 1” is predefined. All configuration settings, e.g. in the user groups or in the trunk group configuration, apply to this predefined default company if not other company has been selected.
Companies are set up and managed in the PBX Configuration: Compa-
nies menu:
■
A new company is created in this menu using the command New.
Each company can be given a name up to 20 characters long.
This name is then displayed in all configuration dialogue boxes in which company-specific settings can be defined.
■
In this menu a company can be deleted again using the command Delete. If a company is deleted which is still used at other places (in the user groups, for example), the respective configuration is changed to the default company.
■
The name of the default company can be changed, but the default company itself cannot be deleted.
Assigning Users
For each user you must define the company to which they belong. This assignment determines, for example, which company telephone book the user has access to and which company-specific configuration data apply to them.
As the OpenCom 100 manages users in groups, the assignment “user > company” is also established this way. The company to which each user group belongs must be defined for each group. A user group can only belong to one company, i.e. not to several. However, a company can have several user groups. It is therefore possible, in the same way as in the entire system, to allocate a range of authorisation rights for the use and configuration of features for each company.
When setting up a new user group
(in the User Manager menu), you will find that the default company is predefined; another company can be assigned as long as no other companies have been set up.
98
Configuring the Multi-Company Variant Multi-Company Variant
Assigning Trunk Groups
Connections of the same type and in the same direction are arranged in a trunk group (e.g. S
0 multi-terminal connections). To be able to correctly transfer incoming calls to the members of the configured companies
(the users) via the lines of a certain trunk group of the OpenCom 100, each of the available trunk groups must be assigned to one of the companies. This is necessary to be able to transfer incoming external calls to the correct company exchange in cases where the called internal subscriber cannot be reached (“Connection to Operator”), for example.
The assignment of trunk groups to companies is done in the
PBX Configuration: Trunks: Bundle
menu.
For outgoing external calls which users set up via the lines of their company’s trunk group, the assignment of the trunk group to the company is irrelevant: the charges are assigned according to the “source” principle.
Charges are billed to the company to which the user belongs who set up the connection. The OpenCom 100 recognises this on the basis of the assignment between user groups and companies and on the basis of the routing code with which a line of the trunk group was seized. For more information, please see the following section.
Allocating Routing Codes
Routes are used for automatic and selective seizure of trunk groups or connections for external calls. It is possible to seize a route by predialling a code.
In the PBX Configuration: Trunks:
Route menu, you can define which company can seize each route. An individual code for the seizure is allocated per route for each company.
The OpenCom 100 ensures that during configuration no seizure code is allocated twice (for two different routes) for each company. If during configuration of a route no code is allocated for one of the configured companies, the route concerned cannot be seized by the members
(user groups) of this company.
Configuring the Company
Exchange
An internal telephone number must be set up for each company which represents the exchange, i.e. “the operator”. The calls to specific extensions arriving at the exchange are routed to this number, for example, as are all external calls where the called subscriber (a user who belongs to this company) cannot be reached, as in the case of a timeout.
Multi-Company Variant Configuring the Multi-Company Variant
99
A company exchange is set up in the
PBX Configuration: System: Opera-
tor menu. In this menu, you can specify an internal telephone number for each company and time group which then represents the exchange for this company.
Working with the Multi-Company
Variant
All the features of the OpenCom 100 which the users may already be familiar with from the single-company variant are available in the multicompany variant. These features can be used to the same extent and can be used in exactly the same way.
The following section describes the features additionally available to the users in the multi-company variant.
Company Telephone Book
An individual company telephone book can be created for each company. In addition to this, “personal” and “central” telephone books exist:
■
A personal telephone book is available for each user.
■
The central telephone book can be used across the companies by all users of the OpenCom 100.
The company telephone book is a central telephone book for the whole company. It is only available to the users/user groups who are assigned to this company. You can also define whether the members of each user group may edit the company telephone book or not.
The company telephone book is treated exactly the same way on the system terminals as the other types of telephone books. This means that the entries listed in the personal, central and company telephone books are displayed on the system phones at the same time.
Users can also use the telephone book of their company with the
OpenCTI 50 Web applications and
phone book, assuming they are authorised to use these applications.
In addition, it is also possible to assign a user group with the authorisation to edit foreign company tele-
100
Working with the Multi-Company Variant Multi-Company Variant
phone books. This authorisation is useful if members of this group - e.g. the “Administrators” - service the entire system. Foreign telephone books can only be edited in the Con-
figurator in the Phone Book menu.
The number of entries in a company telephone book is unrestricted. The
OpenCom 100 can manage up to
2,000 entries in all telephone books
(in the central, personal and company telephone books).
Making Calls Between
Companies
All users of the OpenCom 100 can make internal calls to one another, irrespective of which company they belong to. Calls between users from the different companies are therefore not subject to any restrictions.
Billing Charges per
Company
In the Costs Web application you can output the charges for each company.
Users who are authorised to use this application can view the charges for each company.
Multi-Company Variant Working with the Multi-Company Variant
101
Configuring the PC Software
Further possibilities of use can be implemented on a workstation PC with the Windows operating system by installing drivers and programs.
You can find the installation programs required for this on the system CD that comes with the
OpenCom 100.
Proceed as follows to install extra software:
1. Log on under Windows NT or
Windows 2000/XP as the administrator.
2. Insert the system CD.
If your PC is suitably configured, the CD will start automatically.
Otherwise select “Run” from the
Start menu. Click on the
“Browse” button to look for the program “cd_start.exe” on the
CD. Then confirm this with
“Open” and “OK”.
3. Choose the required option from the start mask and follow the program instructions.
Further instructions for various options that are available are given below.
Setting up TAPI
With a TAPI (Telephony Application
Programming Interface) you can operate a CTI application (computer telephony integration). Here, the CTI application uses the services of the
OpenCom 100 with the help of the
TAPI driver installed on a Windows
PC.
Requirements
You require an active IP network connection between the PC and the telephone system. Refer to the chap-
ter entitled Configuration under Win-
dows starting on page 48 if you have
not yet established an IP network connection. CTI functions can be used only in conjunction with system telephones.
You must therefore have configured at least one user for a system telephone. In addition, you require a
TAPI 2.1-compatible CTI application, for example the Phone Dialer included in the Windows operating system.
102
Setting up TAPI Configuring the PC Software
Installing the TAPI Driver
1. Call up the start mask from the
system CD (see Configuring the
2. Select “Software, TAPI Service
Provider” from the start mask and follow the program instructions.
Configuring the TAPI Connection
Note: Under Windows NT or Win-
dows 2000/XP you should log on as the user for whom you want to configure the TAPI connection.
1. In the Start menu, select “Settings > Control Panel”. Doubleclick on the “Telephony” icon
(“Phone and Modem Options” icon under Windows 2000/XP).
2. Change to the “Telephony Drivers” tab (“Advanced Options” tab under Windows 2000/XP).
3. From the list of installed driver software, select “OpenCom 100
Service Provider” and click on
“Configure”.
4. In the following dialogue you will find a list with the configured connections for the user who is currently logged on. Click on “New”.
5. In the following dialogue you provide information for the new connection. In the “Connection name” box you can enter a descriptive name for the connection. In the “CTI server” box you must enter the DNS name or the
IP address of the OpenCom 100.
Using the “…” button you can search for this in the LAN. In the boxes “Username” and “Password” you enter the user data of one of the users configured on the OpenCom 100. This user must be allocated a system telephone. Confirm your entry with
“OK”.
6. The new connection is now configured. Close the opened dialogues with “OK” and “Close”.
Testing the TAPI Function
1. In the Start menu, select “Programs > Accessories > Communication” and then start the program called “Phone Dialer”.
Under Windows XP the “Phone
Dialer” is started indirect by using the dialling function of the
“Address book” (can be found in the start menu under
“Programs >Accessories”). A manual start of the program file
“Dialer.exe” in the “C:\Program files\Windows NT” folder is possible also.
2. In the “Tools” menu, select the item “Connect using...” to select the system telephone that is to
Configuring the PC Software Setting up TAPI
103
use the CTI application. Under
Windows 2000/XP you select the item “Options” from the “Edit” menu. In the “Lines” tab you then select the system telephone from the “Phone calls” list.
3. Enter a telephone number in the
“Number” box and confirm with
“Dial.” Under Windows 2000/XP you first click on the “Dial” icon and in the subsequent dialogue activate “Phone call”.
4. The number you entered is displayed on the selected system telephone. Lift the receiver to start dialling.
Note: If the “Phone Dialer” pro-
gram is not installed, you will have to install it. To do this, you open the
“Control Panel” and click on “Software”. In the “Windows Setup” tab you activate the “Connections” component.
Setting up NET CAPI
With a CAPI driver (common application programming interface) Windows programs are able to access services and functions of an ISDN card. With a network-based CAPI, the OpenCom 100 allows the use of
ISDN functions also by PCs in which no ISDN card is integrated.
Requirements
You require an active IP network connection between the PC and the telephone system. Refer to the chap-
ter Configuration under Windows starting on page 48 if you have not
yet established an IP network connection.
Please note: Before installing the
CAPI driver for the OpenCom 100, any existent ISDN card must be removed and any CAPI drivers on your PC must be de-installed.
Installing the NET CAPI driver
1. Call up the start mask from the
system CD (see Configuring the
2. Select “Software, NET CAPI
Driver” from the start mask and follow the program instructions.
Configuring the NET CAPI Driver
The NET CAPI driver requires an extra internal number so that the “virtual
ISDN card” on the OpenCom 100 can be addressed:
104
Setting up NET CAPI Configuring the PC Software
1. Go to the Configurator, NET
Configuration: Connections:
CAPI menu. Click on Change.
2. Activate the Status check box.
Enter at least one unassigned, internal number in the boxes under Parameters. Confirm your entry with Assign.
3. Go to the Configurator, User
Manager: User menu. Select one of the users shown. Enter the number just assigned in one of the boxes No. 1 to No. 10.
Confirm your entry with Apply.
4. If it is to be possible to call the
“virtual ISDN card” externally, or if external calls are to be possible, the number must be included in call distribution (Con-
figurator, PBX Configuration:
Call Distribution menu).
5. After installing the NET CAPI driver, you will find an extra icon on the right side of the Windows
Start bar. Click on this icon with the right mouse key. Select the
Log-on command from the menu.
Note: In the subsequent dialogue
you must log on NET CAPI first with
the user (user name and password)
for which you configured the CAPI tel-
ephone number in the User Man-
ager (see Step 3).
You will find further information on the working of the NET CAPI driver and CAPI application programs on the system CD.
Using the Systray Display
You can configure a systray display for the OpenCom 100 to appear in the information area of the Start bar of a workstation. This systray display constantly shows you whether an
ISP, an RAS or a LAN-to-LAN connection is active. It is also possible to display the current occupancy of the trunk lines.
Requirements
To use the systray display, you must
first install TAPI; see Setting up TAPI starting on page 102.
Please note: The systray display
requires a current version of TAPI. If you are using TAPI from an earlier version of the OpenCom 100, you must first install the newer version from the system CD.
Configuring the PC Software Using the Systray Display
105
Installing the systray display
1. Call up the start mask of the sys-
tem CD (see Configuring the PC
2. From the start mask, select
“Software, install systray”. Follow the program instructions.
3. Start the copied program by
“Start > Run” and the configuration dialogue is displayed. Select one of the entries displayed under Existing PBXs. Enter your user name and password in the boxes under Log-on.
4. If you activate the Autostart check box, you will see the systray display even after restarting your PC.
5. Confirm the entries in the configuration dialogue with OK and the systray display logs on for the OpenCom 100.
6. Right-click on the systray display in the Start bar. Select
Configuration to call up the configuration dialogue. Select
Network Connections or Trunk
Lines to produce a status dialogue.
Browser for OpenCTI
You can simplify the daily use of the
OpenCTI using the Web browser especially adapted for the
OpenCom 100. Each time the workstation is restarted, this browser program can automatically start and log you in. This means the OpenCTI is always operational and can be accessed using the icon in the information area of the task bar.
Installing the browser for
OpenCTI
1. Call up the start mask from the
system CD (see Configuring the
2. From the start mask, select
“Software, Install browser for
OpenCTI”. Follow the program instructions.
3. Follow the program instructions.
106
Browser for OpenCTI Configuring the PC Software
After installing the browser, there is a new menu entry in the Windows start menu under Programs:
OpenCTI Browser.
Further information can be found in the online help of the browser program. To view this, click the top left corner of the program window on the system menu icon or on the icon in the information area of the task bar. Select the Readme command.
Synchronising the PC Clock
With the network service SNTP (simple network time protocol) it is possible to synchronise the internal clock of a PC with the time of the
OpenCom 100.
Requirements
You must enter the time zone so that the OpenCom 100 can calculate the time of the internal clock back to the
GMT (Greenwich Mean Time) required for SNTP:
1. Go to the Configurator, SYS
Configuration: System menu.
Click on Change.
2. Under Internet time (SNTP), enter the Time zone for which the time of the OpenCom 100 applies and whether summer time is allowed for. Confirm this with
Assign.
Configuring SNTP
For various operating systems, you can use one of the numerous SNTP programs offered for downloading on the Internet. Configure the
OpenCom 100 as an SNTP server for such programs.
SNTP with Windows 2000
Here you configure the SNTP server as follows:
1. Log on as the administrator.
Start the “Command Prompt” under “Start > Programs > Accessories”.
2. Enter the command line “net time /setsntp:192.168.99.254”.
Confirm with the enter key. This command changes the setting for the SNTP server address in the system registry. Close the command line.
3. Open the “Services” dialogue under “Start > Settings > Control Panel > Administration”. Set the autostart type of the “Windows Timer” service to “Automatic”. Start the service with
“Process > Start”. Every time the
Configuring the PC Software Synchronising the PC Clock
107
service starts, the PC clock is synchronised with the time of the OpenCom 100.
Please note: In a Windows do-
main network, the PDC server (primary domain controller) should automatically assume the function of the timer.
SNTP with Windows XP
Here you configure the SNTP server by double-clicking on the time in the
Start bar. Enter the OpenCom 100 as the “server” in the “Internet time” tab.
Address Queries using LDAP
You can search the data of the central telephone book of the
OpenCom 100 from a workstation in the LAN using LDAP (Lightweight Directory Access Protocol”). When configuring an LDAP-enabled program, specify the IP address of the
OpenCom 100 as the address of the
LDAP server.
LDAP with Outlook Express
You can configure and operate the
LDAP directory service with Outlook
Express
TM
, a Microsoft
TM
e-mail program, as follows:
1. Call up the Accounts command in the Tools menu.
The Internet Accounts dialogue
box will then open.
2. Click on Add. Select the Direc-
tory Service command from the pop-up menu.
The Internet Connection Wiz-
ard dialogue box for Internet access will then open.
3. Under Internet directory
(LDAP) server, enter the ad-
dress of the OpenCom 100. It is not necessary to log in to the
LDAP server. Click twice on
Next. Then click on Finish.
4. Check the function. In the Edit menu, call up the Find: People command.
The Find: People dialogue box will then open.
5. In the Look in list, select the entry with the OpenCom 100 address. Enter a user in the Name input field, Administrator for example. Then click on Find now.
108
Address Queries using LDAP Configuring the PC Software
The list of entries found should now display the address from the central telephone book.
Note: Only users can be found for
whom an internal telephone number has been configured.
USB DECT Box on the OpenCom 100
General Information
The USB DECT Box provides a PC with a wireless ISDN data connection
(DECT). The Box is connected to the
PC via the USB interface and uses the
RFP 21/23 to create a connection to the OpenCom 100 and its network, to the telephone network and to the
Internet.
Note: Up-to-date information on
the USB DECT Box can be found at http://www.detewe.de/.
Installation and
Configuration
1. Connect the RFP 21/23 to a free
U pn
interface on the
OpenCom 100. Instructions on how to do this can be found in
the section Upn Ports starting on page 24.
2. Configure the RFP 21/23 in the
Configurator, using the PBX
Configuration: Ports: U pn
menu.
3. Install the software of the USB
DECT Box and then connect the
USB DECT Box to your PC. Further information on this can be found in the corresponding chapter of the “USB DECT Box” manual (which is included with the USB DECT Box).
4. Create a new DECT device of the type USB DECT Box in the Con-
figurator (menu PBX Configu-
ration: Ports: DECT-PP) and assign a telephone number for the data port.
5. Check the USB DECT Box in. Further information on how to do this can be found in the corresponding chapter of the “USB
DECT Box” manual and in the online help provided in the
OpenCom 100.
6. Assign a user to the telephone numbers of the USB DECT Box in the Configurator (menu User
Manager: User).
Configuring the PC Software USB DECT Box on the OpenCom 100
109
Tip: We recommend that you create the Internet access indirectly via the RAS access of the OpenCom 100.
If you wish to use the USB Box to dial up an Internet provider directly, follow the instructions in the corresponding chapter of the “USB DECT
Box” manual. If you do this, you can omit the remaining steps.
Please note: The direct dial-up
of an Internet provider offers no
safety mechanisms, whereas accessing the Internet via the OpenCom 100 protects your network/PC by means of filter lists.
7. In the Configurator (menu User
Manager: User), assign the user of the USB DECT Box to a user
group which is allowed to use
RAS access.
8. Configure the Internet access in the OpenCom 100 Configurator
(menu NET Configuration: Con-
nections: ISP). You can edit/create suitable filter lists for the Internet access in the NET
Configuration: Safe Access menu.
9. Configure the RAS access in the
NET Configuration: Connec-
tions: RAS menu.
10. Configure the communication network. To do this, follow the instructions in the corresponding chapter of the “USB DECT
Box” manual. Do not enter the provider data, though. Instead, use the internal number of the
RAS access and the user name and password of the
OpenCom 100 user.
Detailed information can be found in
the Internet starting on page 125
section of the Frequently Asked Ques-
tions chapter. The information con-
cerning the Internet functionality of the OpenPhone 25/27 also applies to the USB DECT Box.
Technical Data for
Operation on the
OpenCom 100
■
Data transmission with RAS access / Internet access via the
OpenCom 100: Up to 64 kbit/s gross
■
Data transmission with direct dial-up of a provider: Up to 128 kbit/s gross
110
USB DECT Box on the OpenCom 100 Configuring the PC Software
Configuration Guide
The Configuration Guide contains a series of flowcharts that will help you to plan the configuration of the
OpenCom 100 and guide you through the necessary settings step by step, focusing on the network settings. The individual charts are summarised below:
Note: Settings for mail and ISP and
RAS access are only possible by re-
leasing the OpenCom 100 IP pack-
age on the Web console Configurator
in the SYS Configuration: Licences
menu.
■
Overview: This chart gives you an overview of the initial configuration of the OpenCom 100.
■
Configuring PBX Ports: This chart shows you the necessary steps for configuring ports and terminals.
■
Configuring Easy Access: This chart guides you through TCP/IP settings for the OpenCom 100.
■
Configuring ISP Settings: These instructions support you in configuring the Internet access.
■
Configuring RAS Settings: This chart guides you through the configuration of the RAS settings.
■
Configuring LAN-to-LAN Set-
tings: This chart guides you through the configuration of the
LAN-to-LAN settings.
■
Configuring E-Mail: This diagram tells you how to create the requirements needed for configuring the OpenCom 100 e-mail access function.
■
Configuring E-Mail Access: This overview provides instructions on configuring the
OpenCom 100 e-mail access server.
Configuration Guide
111
Overview
Yes
Ethernet network
Connect the OpenCom 100 and the configuration PC to the network
(LAN) exists?
Yes
No
Cross-connected ethernet cable available?
Connect the configuration PC to the OpenCom 100 LAN port.
Enable DHCP.
No
Connect the configuration PC to the OpenCom 100 COM port.
Generate the Dialup Networking entry with “occonfig”.
Start the OpenCom 100 configuration service via your Web browser.
Enter the OpenCom 100 address, for example “http://192.168.99.254”.
User Manager
PBX Configuration
Yes
Create the user groups and users.
Set the system data. Select the access type. Connect the S
0
, U pn
and analogue devices and configure them.
Configure the call distribution scheme.
Configure the Least Cost Routing function: zones, network providers and holidays.
LCR Configuration
Configure OpenCom 100
Least Cost Routing function?
No
Configure OpenCom 100 network functions?
Yes
Enter the licence code for releasing the IP package in the “System
Configuration: Licences” menu.
Easy Access Configuration
No
Dial in (RAS)?
No
Connection (LAN)?
No
Internet?
No
E-mail?
No
Yes
Yes
Yes
Yes
RAS Configuration
LAN-LAN Configuration
ISP Configuration
E-Mail Configuration
Save data
Flowchart: Overview
Finished
112
Overview Configuration Guide
PBX Ports
Do you have ISDN terminals that you wish to operate on an S
0
interface?
Define the access type
Define the external
S
0
interfaces
Set the access type (multiterminal access and/or system access).
Set the external S
0
interfaces and enter the telephone numbers assigned by your network provider.
S
0
terminals Yes
Define the internal S
0 interfaces
Set the internal S
0
interfaces and enter the internal telephone numbers.
No
Do you want to operate system telephones or
DECT terminals?
U pn
terminals Yes
Configure the
U pn
interfaces
Enter the U pn
interfaces and enter the internal telephone numbers.
No No
DECT terminals
Yes
Configure the DECT terminals
Do you want to operate
DECT terminals on the
OpenCom 100?
Check in the DECT terminals and enter the internal telephone numbers.
Do you want to operate analogue terminals
(e.g. a fax machine)?
Analogue terminals Yes
Configure the a/b interfaces
Set the analogue interfaces and enter the internal telephone numbers.
No
Do you want to use a sensor contact on the
OpenCom 100 (e.g. for a door opener)?
Sensor Yes Configure the sensor
Enter the internal telephone numbers for the time groups of the sensor.
No
Do you want to run the
OpenCount program?
COM
No
Finished
Flowchart: Configuring the PBX Ports
Yes
Configure the COM interface
Select the “connection data” option.
Configuration Guide PBX Ports
113
Easy Access
Do you have a computer network?
LAN
Yes
Host name
No
Assign a name to the OpenCom 100.
Finished
Do you have a DHCP server in your network?
Activate the OpenCom 100
DHCP server.
Enter the Ethernet-IP configuration for the OpenCom 100.
Enter the address range of the client computers in your network.
Do you have a DNS server in your network?
Specify the IP address of the OpenCom 100 under “Domain Name Server”. This is transferred as the DNS server to the client computers via DHCP.
DHCP
No
OpenCom 100
DHCP server
Yes
The OpenCom 100 takes the settings from your DHCP server
Ask your network administrator for the address range for the RAS accesses. For this purpose, your administrator must reserve an IP address range for the RAS accesses.
IP address
Network mask
Gateway address
DHCP adresses
Domain name
Client computers are informed of this gateway address via DHCP as a gateway.
Enter the domain name. This name is transferred to the client computers as the domain via DHCP.
DNS
No
OpenCom 100 as
DNS server
Yes
Specify the IP address of your internal DNS server under “Domain Name
Server”. This is transferred as the DNS server to the client computers via DHCP.
Register internal DNS
Enter the address range for the RAS accesses.
PPP addresses
Flowchart: Configuring Easy Access
Finished
114
Easy Access Configuration Guide
ISP Settings
Do you want to configure a new Internet provider?
Enter your provider's dial-in data.
“SYS Configuration: System:
Country” = “German”?
No
Your own ISP
Yes
T-Online
Provider-New: Provider,
Telephone Number,
User Name and Password
Specify the IP address of the DNS in the Internet.
Specify a standard POP server and a standard SMTP server.
Specify the maximum time of inactivity after which the connection to the ISP is cleared down.
Yes
No
Select a provider from the list
Select one of the default providers in
“NET Configuration:
Connections: ISP”.
Domain Name Server
Mail input server and mail output server
Maximum idle time
T-Online: Telephone number,
Access identification, T-Online number, Co-user number and Password
Configure T-Online in “NET:
Configuration: Connections: ISP:
Provider”. You will obtain the access data when you register.
Activate the status and select the provider
Configure the ISP in “NET:
Configuration: Connections: ISP”.
DSL
(PPPoE)
Yes
No
Is your IP address allocated by your provider?
PPP
Yes
Dynamic
Yes
Enter the IP address and network mask you wish to obtain from your provider.
Your own telephone number
Max. connection time per month
Specify the maximum connection time for one month.
No
No
HDLC
Yes
No LAN
Yes
IP address
Network mask
Specify the gateway for the Internet connection.
Gateway
No
Maximum idle time
Specify the maximum time of inactivity after which the connection to the ISP is cleared down.
Select the filter lists. Filter lists are created in “NET Configuration: Safe Access”.
Filter list IN
Filter list OUT
Finished
Flowchart: Configuring the ISP Settings
ISP cannot be configured.
Configuration Guide ISP Settings
115
RAS Settings
Have you made the network settings for the OpenCom 100?
LAN No
NET Configuration:
Easy Access
Configure the network settings for the OpenCom 100.
Configure the RAS access of the
OpenCom 100. “NET Configuration:
Connections: RAS”
Yes
Select from PAP,
CHAP and CLID.
Status
Telephone number
Activate the RAS access.
Specify the telephone number for which the RAS access should be configured.
Authorisation
Number of connections
Specify how many simultaneous connections are possible via this access.
Select the filter lists. Filter lists are created in “NET
Configuration: Safe Access”
Filter list IN
Filter list OUT
Have you created users with RAS access rights?
Users No
Yes
User Manager: Users and
User Groups
Configure users that have RAS access rights.
Add internal telephone number to the incoming call distribution scheme.
Finished
Flowchart: Configuring the RAS Settings
116
RAS Settings Configuration Guide
LAN-to-LAN Settings
Have you made the network settings for the OpenCom 100?
LAN
Yes
Configure the LAN-LAN connection. “NET Configuration:
Connections: LAN-LAN”
Protocol
Telephone number local
IP address local
Network mask local
No
NET Configuration:
Easy Access
Configure the network settings for the OpenCom 100.
Select between PPP and HDLC transparent.
Enter the internal telephone number.
Enter the local IP address.
Enter the local network mask.
Yes CLID
No
User name local
Password local
Authorisation method of the local
LAN: CLID, PAP or CHAP?
Specify the user name with which the remote LAN can access a destination.
Specify the password with which the remote LAN can access a destination.
Telephone number remote
IP address remote
Network mask remote
Specify the telephone number of the remote LAN access.
Specify the IP address of the remote LAN.
Specify the network mask of the remote LAN.
Yes CLID
Authorisation method of the remote
LAN: CLID, PAP or CHAP?
No
User name remote
Password remote
Direction of connection
Maximum connection time per month
Maximum idle time
Add internal telephone number to the incoming call distribution scheme.
Specify the user name with which the remote LAN can be accessed.
Specify the password with which the remote LAN can be accessed.
Select the direction of the connection.
Specify the maximum number of minutes per month the connection to the remote LAN can be set up for.
Set the maximum idle time after which a connection to the remote LAN is cleared down.
Finished
Flowchart: Configuring the LAN-to-LAN Settings
Configuration Guide LAN-to-LAN Settings
117
E-mail Function
Have you made the network settings for the OpenCom 100?
LAN No
Configure the network settings for the OpenCom 100.
NET Configuration:
Easy Access
Yes
Do you want to use e-mail from the Internet?
Internet
No
Yes
Configure your Internet access.
NET Configuration:
Connection: ISP
Has an internal e-mail server been configured in your LAN?
Have you stored the users to be notified?
LAN
Yes
Do you want to be notified of e-mails on your system telephones?
Notification
Yes
Users
Yes
No
No
No e-mail use
Finished
No
Create the users and activate e-mail notification. Also enter the users' e-mail addresses.
User Manager:
Users, User Groups and User Accounts
Set the polling time periods.
NET Configuration:
E-Mail Access
Finished
Flowchart: Configuring the E-mail Function
118
E-mail Function Configuration Guide
E-mail Access
Do you have access to a mail server in your network or in the Internet?
Mail server No
Configure your network/
Internet access.
NET Configuration: Easy Access or Configure ISP
Yes
Do you have created mail account polls in the “User Manager: User accounts”?
User accounts No
Set up user accounts in the User Manager.
User Manager: User Accounts
Yes
Configuration of e-mail access settings
Specify the time intervals in which the OpenCom 100 is to poll all mail accounts from the standard POP server.
Maximum number of e-mails per user account
Enquiry interval
Start and end times:
Monday to Friday 1st starting time
Monday to Friday 1st ending time
Monday to Friday 2nd starting time
Monday to Friday 2nd ending time
Saturday 1st starting time
Saturday 1st ending time
Saturday 2nd starting time
Saturday 2nd ending time
Sunday 1st starting time
Sunday 1st ending time
Sunday 2nd starting time
Sunday 2nd ending time
Specify the maximum no. of e-mails per user account that should be temporarily stored by the OpenCom 100.
Define the time windows in which the
OpenCom 100 should check the mail accounts for new messages in the time intervals that have been set. You can define two time windows for each working day (Monday to
Friday), and two each for Saturday and Sunday.
Flowchart: Configuring E-mail Access
Finished
Configuration Guide E-mail Access
119
Frequently Asked Questions
This chapter provides tips and information on how to deal with any malfunctions or faults you may experience with the OpenCom 100.
Please note: Repairs to the
OpenCom 100 should only be carried out by qualified personnel.
The following LEDs indicate that the
OpenCom 100 is ready for operation:
Power Good LED
Activity LED
LAN LEDs
Interface module
AC adapter
Position of LEDs on the OpenCom 100
The LAN LEDs are only visible on the
OpenCom 110/120when the labelling strip is removed.
120
General/Hardware
Question: The OpenCom 100 is not functioning.
Make sure the mains plug is properly connected.
Plug another device into the mains socket to check whether there is any voltage.
Question: The mains plug is connected, the mains socket is supplying output, but the OpenCom 100 still does not function.
General/Hardware
DANGER! High voltage inside the device. To make the system dead, remove the power plug from the socket!
Take the housing cover off. Is the
“Power Fine” LED at the top left lit up? If not, contact your service centre or an authorised dealer. The AC adapter plug of the OpenCom 100 may be defective.
Question: After restarting the
OpenCom 100, nothing is indicated on the displays of any connected terminals.
Frequently Asked Questions
It takes a short while for the
OpenCom 100 to start up. After the restart, check whether the activity
LED flashes at a rate of 10s / 1s. This flash cycle indicates that the
OpenCom 100 has started up correctly and is ready for operation. If the OpenCom 100 has not restarted properly, reset the OpenCom 100 to its original factory setting (refer to
the chapter entitled Resetting the
System Data starting on page 60).
Telephony
Question: It is not possible to make external calls.
Check the connection between the
NTBA and the OpenCom 100.
In the Configurator, check whether the external S
0
ports are configured correctly (PBX Configuration: S0 menu).
Question: The OpenCom 100 is connected to an NTBA with a multi-terminal configuration. Why is it not possible to establish external connections?
With the original factory setting, an additional external S
0
port is set for an NTBA in system configuration; this additional port will be used first to seize a trunk line.
Deactivate the second S
0
port in the
Configurator (PBX Configuration:
S0 menu).
Question: One of the telephones is not functioning at all.
Make sure the telephone has been properly connected.
Check also whether the appropriate port has been configured correctly in the Configurator (PBX Configura-
tion: Ports menu).
Question: It is not possible to make external calls with one of the telephones.
Check whether a user is configured for the telephone. Otherwise the settings of the Guests user group are valid for the telephone. To standard, this user group has no external call authorisation.
Make sure the user configured for this telephone belongs to a user group with external line access
(Configurator, User Manager: User
groups menu).
Check also whether the internal call number of this telephone has been configured for outgoing call distri-
Frequently Asked Questions Telephony
121
bution (Configurator, PBX Configu-
ration: Call Distribution menu).
Question: One of the features
(e.g. call diversion) on one of the telephones cannot be used even though the feature has been configured in the Configurator of the
OpenCom 100.
Make sure the user configured for this telephone belongs to a user group that has access to this feature
(Configurator, User Manager: User and User groups menus). Some features cannot be used until the system PIN is changed.
Question: Nothing is indicated on the display of one of the connected
ISDN telephones.
You have connected the ISDN telephone to an external S
0
port (RJ-45 socket). These ports are intended for connection to the NTBA only. Connect the telephone to an internal S
0 port (pressure terminal).
Question: Calls can be made but not received with one of the ISDN telephones.
The internal call number that has been configured for this ISDN telephone in the Configurator (PBX
Configuration: Ports: S0 menu) must also be configured as an MSN on the ISDN telephone itself. For further information, refer to the User
Guide of your ISDN telephone.
Question: It is not possible to configure Call Distribution: Outgoing for multi-terminal access.
You have configured multi-terminal access and system access in parallel.
All outgoing calls are therefore established via system access, and outgoing call distribution can be configured for system access only
(Configurator, Call Distribution:
Outgoing menu).
A specific MSN can be seized for individual calls by means of a code number procedure. For further information, refer to the “OpenCom 100,
Operation on Standard Terminals”user guide.
Question: Which reason may have problems with receiving faxes resp. sending faxes?
In frequent cases, the reason may be found in a problem with the ISDN-L1 reference clock distribution. The L1 clock is delivered from the network provider. An unclean L1 clock distribution and the introduced signalling jitter is overheard by the human ear.
Nevertheless, data and fax transmissions may be disturbed by the jitter.
Please check, which ISDN lines will deliver the L1 clock. Details can be
found under L1 Clock starting on page 77.
122
Telephony Frequently Asked Questions
DECT
Question: The LED of the RFP 21/
23is flashing, but none of the DECT devices is functioning.
Make sure the terminal setting for the corresponding U pn
port is set to
RFP 21/23 (Configurator, PBX Con-
figuration: Ports: U pn
menu).
Question: The LED of the RFP 21/
23 is continuously lit up, but one of the cordless DECT devices is indicating “No connection”.
You have not configured a port for this DECT device. Configure a port in the Configurator and start the enrolment procedure (PBX Configura-
tion: Ports: DECT-PP menu).
Question: Is it possible to increase the time for the enrolment procedure?
You must manually enter the IPEI of the DECT device in the Configurator.
The enrolment time is then increased to one hour (PBX Configura-
tion: Ports: DECT-PP menu).
Question: Another manufacturer’s DECT device is not functioning.
Check whether the DECT device supports the DECT GAP standard. In the
Configurator, also make sure GAP is set for this DECT device (PBX Config-
uration: Ports: DECT-PP menu).
Question: The startup procedure of the RFP 21/23 take a long time?
What is the reason?
This behaviour may indicate a problem with the reference clock. Refer
also to Which reason may have prob-
lems with receiving faxes resp. send-
ing faxes? starting on page 122.
Frequently Asked Questions DECT
123
LAN
Question: It is not possible to establish a network connection with the OpenCom 100.
Check whether the LEDs for the hub and the PC’s network card are indicating a connection.
Remove the labelling strip. Check the LEDs for the LAN functions of the
OpenCom 100. The upper green LAN
LED at the top indicates whether the network cable has been properly connected. The lower red LAN LED at the bottom indicates whether there is any network traffic on the line.
To check whether there is a network connection with your OpenCom 100, enter the “ping IP address” command in “Run” in the Windows Start menu (e.g. ping 192.168.99.254).
Question: How can I determine the IP address of the
OpenCom 100?
To find out what the IP address is, enter the code number
* 1 8 2 on one of the connected system telephones.
The code-number procedure
* 1 8 3 also displays the network mask.
Question: The network connection is functioning, but nothing is displayed in the browser.
Enter the complete IP address of the
OpenCom 100 along with the protocol identifier, for example http://
192.168.99.254/.
Check whether the browser has been configured for connection through a proxy server. If so, deactivate the “Connect through proxy server” setting.
Question: You have just configured the OpenCom 100 via the network. Why is it not possible now to establish a remote data transfer network connection?
The network card and the communication (remote data transfer) adapter cannot be run with the same routing setting. Deactivate the network card before connecting via the dial-up network.
Question: Our network has grown over time, with several segments connected by one central router.
How can PCs from all segments be connected with the OpenCom 100?
In the Configurator, use the LAN setting in ISP to specify the central router as the default gateway. If necessary, deactivate any filter rules de-
124
LAN Frequently Asked Questions
fined for the ISP (NET Configura-
tion: Connections: ISP menu). If several routers are configured for your network in different segments, you can enter extra static routes in the NET Configuration: Easy Access:
Routes menu.
Question: In our network the
OpenCom 100 dynamically issues the IP addresses by DHCP. Can I firmly assign the IP address for our internal server PCs (mail, Web)?
You need a static address assignment for these PCs. Make the appropriate assignment entries in the
Configurator (NET Configuration:
DHCP menu). Activate “Dynamic and static address”. If you fix a name for these IP addresses in the NET Con-
figuration: Easy Access: Hosts menu, you can address the server
PCs quite easily by the DNS names.
Internet
Question: I cannot access our company Web site.
Outside your system, your company
Web site is accessed at
“www.firm.com”, but in the Config-
urator you have entered “firm.com” as the domain. Your company’s site
URL thus counts as an internal URL and can only be accessed by entering the direct IP address. If required, change the domain setting in the
NET Configuration: Easy Access
menu.
Question: Why do some Internet services not work even though they can be used when dialling in directly via a modem?
Some Internet services require an active connection coming from the
Internet. But the configured filter rules prevent this. Plus, it is not possible to establish incoming Internet connections with the PCs directly owing to the network address translation process.
Question: It is not possible to access the Internet with the
OpenPhone 25/27.
The requirement for this is that the set should be configured as Hand-
set+data. The telephone number used by the OpenPhone 25/27 to establish an Internet connection must also be specified in the respective user profile (Configurator, User
Manager: User menu).
With the OpenPhone 25/27, the Internet can be accessed either di-
Frequently Asked Questions Internet
125
rectly via the remote data transfer network or indirectly via RAS access on the OpenCom 100. For direct access you can directly dial any provider. Indirect access uses the routing function of the OpenCom 100, accompanied by the configured security features, for example.
Directly via remote data transfer network
If the Internet is accessed directly via the remote data transfer network, make sure that
■ the remote data transfer network is properly installed on your PC and that the correct ISP access data is configured,
■ the internal number used by the
OpenPhone 25/27 to establish the data connection is configured for outgoing call distribution (Configurator, PBX Config-
uration: Call Distribution:
Outgoing menu).
Indirectly via RAS access
If the Internet is accessed indirectly via RAS, the system administrator should make sure that:
■ permission has been given for
Internet access via RAS (Config-
urator, Net Configuration: Safe
Access menu),
■ an internal number is configured for RAS access (Configurator,
Net Configuration: Connec-
tions: RAS menu),
■ your user group has been granted RAS access rights (Con-
figurator, User Manager: User
Groups menu).
For information on the installation of software and on configuring Internet access, refer to the
“OpenPhone 25” user guide or to the
“OpenPhone 27” user guide.
126
Internet Frequently Asked Questions
Technical Specifications
Mains power supply
Rated power
Safety class
Euro ISDN external for basic access, DSS1 protocol
230 V ~ 50 Hz
OpenCom 105:
80 VA
2
OpenCom 105:
1x
OpenCom 110:
80 VA
OpenCom 110:
2x
Euro ISDN internal for ISDN terminals, DSS1 protocol
OpenCom 105:
1x
OpenCom 110:
1x
– Supply voltage
– Supply power
– Range
Euro ISDN switchable for basic access, DSS1 protocol or for ISDN terminals, DSS1 protocol
– Supply voltage
– Supply power
40 V ± 10%
3 W
150 m
OpenCom 105:
2x
OpenCom 110:
2x
– Supply voltage
– Supply power
– Range
40 V ± 10%
3 W for internal
– Range 150 m internal
U pn
for system terminals and DECT base stations
OpenCom 105:
4x
OpenCom 110:
8x
40 V ± 10%
3 W per U pn
bus
1000 m a/b for analogue terminals with pulse or DTMF dialling, flash duration of 60 to 310 ms
OpenCom 105:
4x
– Supply voltage 40 V ± 10%
OpenCom 110:
4x
– Supply power
– Range
V.24 port (COM)
– Range
25 mA
1,000 m for connection of a PC
5 m
OpenCom 120:
130 VA
OpenCom 120:
—
OpenCom 120:
—
OpenCom 120:
6x
OpenCom 120:
18x
OpenCom 120:
4x
Technical Specifications
127
Permissible temperatures stationary, weatherproofed
Dimensions (B x H x D)
Weight (only system)
Contact load actor 1
Contact load actor 2
– Voltage range
Sensor, switched by low AC voltage
– Voltage range
+5°C to +40°C
396 x 390 x 100 mm
OpenCom 105: about 2.8 kg
OpenCom 110: about 2.8 kg
10 A / 125 V
2 A / 125 V
U
≈
= 5 V … 30 V
OpenCom 120: about 3.2 kg
U
~
= 6 V … 24 V
Note: The online help provides an
overview of the limits that should be observed when configuring the
OpenCom 100.
128
Technical Specifications
Index
A
Actor
Adapter
B
C
Establishing a network connection 51
Installing the remote data transfer network under Windows 9x 50
Saving and loading the configuration 59
OpenCom 100 in a LAN with an IPenabled server 66
Configuration guide
Configuring
Connection scheme
Index
129
130
D
E
F
H
Hardware basic setting switch 60
I
Interfaces
L
M
N
O
P
Index
Pin assignment
Port assignment
Ports
Q
R
S
Index
Safety
Saving and loading the configuration 59
Sensor
T
Team functions
U
V
131
Notes
132
Index
Configuration Example
OpenCom 110
RFP 21
OpenPhone 63
Upn
Upn
RFP 21
Upn
Analogue fax a/b
S0
ISDN telephone
Configuration example: OpenCom 110 with connected terminals
OpenPhone 21
In the UK:
DeTeWe Ltd
1 Frogmore Road, Hemel Hempstead,
Herts, HP3 9TG
WWW: http://www.detewe.co.uk/
Other countries:
DeTeWe AG & Co.
Zeughofstrasse 1, D-10997 Berlin,
Germany
WWW: http://www.detewe.de/
Subject to changes
As of 06.2004