Notes. DETEWE opencom 100, opencom 105, opencom 120, opencom 107, opencom 110
Tangazo
Tangazo
The master system then initialises the slave system. This may involve transfer of firmware (operating software) from the master system to the slave system.
This can take a few minutes.
7. Configure the system telephone connected to the slave system for testing purposes in the Con-
figurator. In the
PBX Configuration: Ports: Upn dialogue, click on one of the additionally displayed entries of the type Upn 1/n (1: slave system, n: U pn
port number).
Note: Changes to the configura-
tion while initialising the slave system may trigger error reports referring to the ongoing initialisation.
You can see that the initialisation has been completed from the display on the system telephone connected to the slave system.
Notes
Observe the following when operating a cascaded PBX system:
■
All U pn
, S
0
and a/b ports of the slave system can be used with appropriate telephones. All features of system telephones on
U pn
ports are available without restriction.
■
The S
0
ports of the slave system can also be used for trunk lines
or for PBX networking (see PBX
Networking starting on page 76).
■
It is not possible to operate a
DECT base station on one of the
U pn
ports of the slave system.
■
The COM, actor/sensor and –if present– LAN2 ports of the slave system cannot be used.
■
The two communications systems must have a direct Ethernet connection or be connected via a hub in order to exchange data. They cannot be connected through a router.
■
The slave system cannot be addressed directly through a LAN.
For configuration, always use the Web console of the master system.
■
A memory card installed in the slave system (OpenVoice, Open-
Attendant) cannot be used.
■
To operate the slave system again normally, you must reset it to its factory settings (refer to
Resetting the System Data starting on page 60).
PBX Networking PBX Cascading
75
Pakua
Tangazo