x900 Series Switch and SwitchBlade
®
x908
Hardware Reference
AT-8948 x900-48FE x900-48FE-N x900-48FS
AT-9924T
AT-9924SP
AT-9924Ts x900-12XT/S x900-24XT x900-24XT-N x900-24XS
SwitchBlade ® x908
x900 Series Switch and SwitchBlade
®
x908
Hardware Reference
AT-8948 x900-48FE x900-48FE-N x900-48FS
AT-9924T
AT-9924SP
AT-9924Ts x900-12XT/S x900-24XT x900-24XT-N x900-24XS
SwitchBlade
®
x908
Download the complete document set from www.alliedtelesis.com/support/software
x900 Series Switch and SwitchBlade
®
x908 Hardware Reference
Document Number C613-03092-00 REV J
© 2009 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc.
Allied Telesis, Inc. reserves the right to change specifications and other information in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesis, Inc. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesis, Inc. has been advised of, known, or should have known, the possibility of such damages.
Allied Telesis, AlliedWare, AlliedWare Plus, and SwitchBlade are trademarks or registered trademarks in the United States and elsewhere of Allied Telesis, Inc. Adobe,
Acrobat, and Reader are either registered trademarks or trademarks of Adobe Systems
Incorporated in the United States and/or other countries. Microsoft and Visio are either registered trademarks or trademarks of Microsoft Corporation in the United States and/ or other countries. Additional brands, names and products mentioned herein may be trademarks of their respective companies.
Hardware Reference
Contents
Fast Ethernet RJ-45 port LEDs ................................................................... 15
Out-of-Band Ethernet Management Port .................................................. 19
Dual In-line Memory Module (DIMM) ....................................................... 29
3
C613-03092-00 REV J
4 x900 Series Switch and SwitchBlade
®
x908
RS-232 Terminal and Modem Cables ........................................................ 30
Cables for RJ-45 Ethernet LAN Interfaces .................................................. 31
PWR01 AC and DC PSUs .......................................................................... 36
PWR05 AC and DC PSUs .......................................................................... 37
x900-12XT/S fixed AC PSU ....................................................................... 38
Displaying information about the card ...................................................... 41
Using Windows Terminal and HyperTerminal ................................................... 44
AlliedWare Plus Operating System Startup ................................................ 48
Operating System Startup on AT-9924Ts, x900-24XT, and x900-24XS Switches ................................................................... 48
Enabling diagnostics mode ....................................................................... 58
Running a diagnostic program .................................................................. 59
Obtaining Documentation and Resources ........................................................ 62
C613-03092-00 REV J
Hardware Reference
Devices Covered by this Document
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
This Hardware Reference contains information on the following devices:
AT-8948 switch x900-48FE switch x900-48FE-N switch x900-48FS switch
AT-9924T switch
AT-9924SP switch
■
AT-9924Ts switch x900-12XT/S switch x900-24XT switch x900-24XT-N switch x900-24XS switch
SwitchBlade
®
x908 switch
AT-PWR01 AC and DC power supply units
AT-PWR02 AC power supply unit
AT-PWR05 AC and DC power supply unit
AT-FAN01 fan-only module
AT-FAN03 chassis fan
You can download the complete document set for x900 Series switches and
SwitchBlade x908 from www.alliedtelesis.com/support/software . For more
information about the document set and other resources, see “Obtaining
Documentation and Resources” on page 62 .
5
C613-03092-00 REV J
6 x900 Series Switch and SwitchBlade
®
x908
48-Port Fast Ethernet Switches
■
■
■
■
These Fast Ethernet switches meet the exceptionally high performance demands of high-end applications:
AT-8948 x900-48FE x900-48FE-N (NEBS compliant model) x900-48FS
Dimensions
■ Height: 44.5 mm, plus 5.1 mm if the rubber feet are used
■
■
■
Width: 440 mm, excluding rack-mounting brackets
Depth: 440 mm, excluding PSU handles
Weight: Not more than 7.3 kg (16.1 lbs) unpackaged, which includes one power supply unit (PSU) and one fan-only module (FOM)
Mounting system
■ 1U rack
■ 19-inch rack-mount kit
Asynchronous serial port
■
■
■
■
Up to 115 kbps
Universal Asynchronous Receiver Transmitter (UART)
Standard RJ-45 connector
Hardware flow control
Environmental conditions
■
■
■
■
■
Operating temperature range: 0º C to 50º C (32 to 122º F)
Storage temperature range: -25º C to 70º C (-13 to 158ºF)
Relative humidity range for operation: 5 to 80% non-condensing
Relative humidity range for storage: 5 to 95% non-condensing
Operational altitude: 3,050 metres maximum (10,000 feet)
Regulatory standards
■
■
■
■
EMC: EN55022 class A, FCC class A, and VCCI class A
Immunity: EN55024, EN61000-3 levels 2 (Harmonics), and 3 (Flicker)—
AC models only
Safety: UL60950-1, CAN/CSA-C22.2 No. 60950-1-03, EN60950-1,
AS/NZS60950.1, and EN60825-1
Certification: UL, cUL, and TUV
Switching core
■ Application-Specific Integrated Circuit (ASIC) switch chip
■ Non-blocking Layer 2 and Layer 3 IP switching
■
■
■
■
■
■
256 kBytes IPv4 address table x900-48FE and x900-48FS switches are IPv6-ready in hardware to provide accelerated unicast and multicast routing
4096 Layer 2 multicast entries
1024 Layer 3 IPv4 multicast entries
4 096 logical IPv6 interfaces
Separate packet buffer memory
C613-03092-00 REV J
Hardware Reference 7
Processing core
■ 350 MHz RISC Processor
■
■
■
■
■
■
32 MBytes of on-board flash
256 MBytes of Synchronous DRAM, expandable to 512 MBytes with DIMM
CompactFlash slot for hot-swappable expansion of flash memory
512 kBytes of SRAM
32/66 PCI bus for 32-bit/33 MHz
Silicon ID chip stores serial number, board ID, and MAC address
IPv6 accelerator card
AT-8948 switches have a slot for an optional AT-ACC01 network processor accelerator card to provide accelerated unicast and multicast routing in hardware:
■ 4096 Layer 3 IPv6 multicast entries
■
■
1000 accelerator hardware filters
128 MBytes Synchronous DRAM giving 64 K IPv6 routes
AT-8948 and x900-48FE switches
■
■
Key features are:
■ Autonegotiating, multi-layer Fast Ethernet switch
■
■
48 x 10BASE-T/100BASE-TX ports (RJ-45 connectors), auto MDI/MDI-X, full or half duplex
4 x 1000BASE-X SFP uplink port, 1000 Mbps, full duplex
■
Hot-swappable, load sharing PSUs
NEBS compliant model x900-48FE-N available
Optional AT-ACC01 network processor accelerator card for the AT-8948 switch x900-48FE front panel
1 2 3 4 5 6 7 8
Advanced L3 Switch
PSU 1 PSU 2 FAULT CF
RESET
ASYN0/CONS
19 20 21 22 23 24 25 26 27 28 29 30 31 32 35 36 37 38 39 40 41 42 43 44 45 46 47 48
L/A 49 50 51 52 SFP
PORTS 49-52 LINK ACT SFP ENABLED FAULT L/A D/C PORTS 1-48 LINK 100M ACT LINK 10M ACT D/C FULL DUP HALF DUP COL
x900-48FS switch
Key features are:
■
■
■
■
■
Multi-layer Fast Ethernet switch
48 x 100BASE-X SFP ports, 100 Mbps, full or half duplex
4 x 1000BASE-X SFP uplink ports, 1000 Mbps, full duplex
Support for hot-swappable SFP modules
Hot-swappable, load sharing PSUs x900-48FS front panel
ASYN0/CONS
C613-03092-00 REV J
8 x900 Series Switch and SwitchBlade
®
x908
Gigabit Switches
■
■
The AT-9900 series switch provides advanced Gigabit Ethernet multi-layer switches that are perfect for the high-density rack environment where space is at a premium:
AT-9924T
AT-9924SP
Dimensions
■ Height: 44.5 mm, plus 5.1 mm if the rubber feet are used
■
■
■
Width: 440 mm, excluding rack-mounting brackets
Depth: 440 mm, excluding PSU handles
Weight: Not more than 7.3 kg (16.1 lbs) unpackaged, which includes one power supply unit (PSU) and one fan-only module (FOM)
Mounting system
■ 1U rack
■ 19-inch rack-mount kit
Asynchronous serial port
■
■
■
■
Up to 115 kbps
Universal Asynchronous Receiver Transmitter (UART)
Standard RJ-45 connector
Hardware flow control
Environmental conditions
■
■
■
■
■
Operating temperature range: 0ºC to 50ºC (32ºF to 122ºF)
Storage temperature range: -25º C to 70º C (-13ºF to 158ºF)
Relative humidity range for operation: 5% to 80% non-condensing
Relative humidity range for storage: 5% to 95% non-condensing
Operational altitude: 3,050 metres maximum (10,000 feet)
Regulatory standards
■
■
■
■
EMC: EN55022 class A, FCC class A, and VCCI class A.
Immunity: EN55024, EN61000-3, levels 2 (Harmonics), and 3 (Flicker)—
AC models only
Safety: UL60950-1, CAN/CSA-C22.2 No. 60950-1-03, EN60950-1,
AS/NZS60950.1, and EN60825-1
Certification: UL, cUL, and TUV
Switching core
■ Application-Specific Integrated Circuit (ASIC) switch chip
■ High performance IPv4 switching with separate packet buffer memory
Processing core
■ 350 MHz RISC Processor
■ 16 MBytes of on-board flash with provision for an additional 16 MBytes
■
■
■
■
CompactFlash card slot on the front panel for hot-swappable expansion of flash memory
256 MBytes of Synchronous DRAM, expandable to 512 MBytes with DIMM
512 kBytes of NVSRAM
Silicon ID chip storing serial number, board ID, MAC address, and hardware revision level
C613-03092-00 REV J
Hardware Reference
AT-9924T switch
Key features are:
■
■
■
■
Autonegotiating, multi-layer gigabit switch
24 x 10BASE-T/100BASE-TX/1000BASE-T ports (RJ-45 connectors)
4 x SFP ports (see “Network Ports” on page 20
for speeds)
Hot-swappable, load sharing PSUs
AT-9924T front panel
9
There can be 24 ports operational at one time. The RJ-45 ports 1 to 4 use the same physical interface as the SFP ports 1 to 4. When an SFP is inserted into an
SFP port, the corresponding RJ-45 port is disabled. For example, if an SFP is inserted in SFP port 1, then RJ-45 port 1 is disabled. When the SFP is removed from port 1, the RJ-45 port 1 is again operational. All other RJ-45 ports function normally.
AT-9924SP switch
Key features are:
■
■
■
Autonegotiating, multi-layer gigabit switch
24 x SFP ports (see “Network Ports” on page 20 for speeds)
Hot-swappable, load sharing PSUs
AT-9924SP front panel
C613-03092-00 REV J
10 x900 Series Switch and SwitchBlade
®
x908
Expandable Gigabit Switches
■
■
■
■
■
■
These gigabit link aggregation switches operate with other switches that have
10 Mb/100 Mb/1 Gb/10 Gb Ethernet ports. These switches can act as a gigabit server backbone or pass aggregated traffic over their gigabit ports. They can also aggregate gigabit desktop user connections and pass traffic to other
10 Gigabit Ethernet equipment. These switches are:
AT-9924Ts x900-12XT/S x900-24XT x900-24XT-N (NEBS compliant model) x900-24XS
SwitchBlade x908
Dimensions
AT-9924Ts, x900-24XT, x900-24XT-N, and x900-24XS
■
■
■
■
Height: 44.5 mm, plus 5.1 mm if the rubber feet are used
Width: 440 mm, excluding rack-mounting brackets
Depth: 440 mm, excluding PSU handles
Weight: Not more than 7.3 kg (16.1 lbs) unpackaged, which includes one power supply unit (PSU) and one fan-only module (FOM)
■
■
■
■ x900-12XT/S
Height: 44.5 mm, plus 5.1 mm with rubber feet attached
Width: 440 mm, excluding rack-mounting brackets
Depth: 350 mm
Weight: Not more than 6 kg (13.2 lbs) unpackaged, which does not include a XEM
■
■
■
■
SwitchBlade x908
Height: 133.5 mm
Width: 440 mm, excluding rack-mounting brackets
Depth: 455 mm
Weight: Not more than 25 kg (55 lbs) unpackaged, which includes dual power supply units, dual chassis fans, and eight XEMs
Mounting system
AT-9924Ts, x900-12XT/S, x900-24XT, x900-24XT-N, and x900-24XS
■ 1U rack
■ 19-inch rack-mount kit
SwitchBlade x908
■ 3U rack
■ 19-inch rack-mount kit
C613-03092-00 REV J
Hardware Reference 11
Asynchronous serial port
■
■
■
■
Up to 115 kbps
Universal Asynchronous Receiver Transmitter (UART)
Standard RJ-45 connector
Hardware flow control on switches running the AlliedWare operating system
Environmental conditions
■
■
■
■
■
Operating temperature range: 0º C to 40º C (32º F to 104º F) derated by 1° C per 305 Meters (1000 ft)
Storage temperature range: -25º C to 70º C (-13º F to 158º F)
Relative humidity range for operation: 5% to 80% non-condensing
Relative humidity range for storage: 5% to 95% non-condensing
Operational altitude: 3,050 metres maximum (10,000 feet)
Regulatory standards
■
■
■
■
■
EMC: EN55022 class A, FCC class A, and VCCI class A.
EN61000-3 levels 2 (Harmonics), and 3 (Flicker)—AC models only
Immunity: EN55024
Safety: UL60950-1, CAN/CSA-C22.2 NO. 60950-1-03, EN60950-1,
AS/NZS60950.1, and EN60825-1
Certification: UL, cUL, and TUV
Switching core
■ Application-Specific Integrated Circuit (ASIC) switch chip
■
■
High performance IPv4 switching
Separate packet buffer memory
Processing core
■ 667 MHz RISC Processor
■ Secure Digital card slot on the front panel for hot-swappable expansion of flash memory
■ 512 kBytes of NVSRAM
AT-9924Ts, x900-24XT, x900-24XT-N, and x900-24XS running the AlliedWare operating system:
■ 32 MBytes of on-board flash
■ 512 MBytes DDR SDRAM x900-12XT/S, x900-24XT, x900-24XT-N, and x900-24XS running the
AlliedWare Plus operating system:
■ 64 MBytes of on-board flash
■ 512 MBytes DDR SDRAM
SwitchBlade x908
■ 64 MBytes of on-board flash
■ 512 MBytes DDR SDRAM SODIMM
Important SODIMM memory is not interchangable with the DIMM memory used on other switches.
C613-03092-00 REV J
12 x900 Series Switch and SwitchBlade
®
x908
AT-9924Ts switch
Key features are:
■
■
■
■
■
■
Autonegotiating, multi-layer gigabit switch
24 x 10/100/1000BASE-TX ports (RJ-45 connectors)
Out-of-band 10/100/1000BASE-T Ethernet management port
Optional Secure Digital memory card
Supports dual, hot-swappable, load sharing PSUs—a second PSU is optional
Two high-speed bays to support a combination of expansion modules:
• AT-A60, 1 x 10 GbE XFP port
• AT-A61, 12 x SFP ports
• AT-A62, 12 x RJ-45 ports
AT-9924Ts front panel
x900-12XT/S switch
Key features are:
■
■
■
■
■
■
Autonegotiating, multi-layer gigabit switch
12 x combo ports that can be either 10/100/1000BASE-TX (RJ-45 connectors) or 100/1000BASE-X SFP ports
Out-of-band 10/100/1000BASE-T Ethernet management port
Optional Secure Digital memory card
Support for hot-swappable SFP modules
One high-speed bay to support the following expansion modules:
• XEM-1XP, 1 x 10 GbE XFP port
• XEM-2XP, 2 x 10GbE XFP ports
• XEM-12S, 12 x SFP ports
• XEM-12T, 12 x RJ-45 ports
• XEM-STK, 2 stacking ports x900-12XT/S front panel x900-12XT/S Advanced L3 Switch
SD POWER FAULT
RESET
ETH0 CONSOLE
MANAGEMENT
LINK 1000M ACT LINK 10/100M ACT FULL DUP HALF DUP COL LINK ACT INSTALLED FAULT
C613-03092-00 REV J
Hardware Reference
x900-24XT switch
Key features are:
■
■
■
■
■
■
■
Autonegotiating, multi-layer gigabit switch
24 x 10/100/1000BASE-TX ports (RJ-45 connectors)
Out-of-band 10/100/1000BASE-T Ethernet management port
Optional Secure Digital memory card
Supports dual, hot-swappable, load sharing PSUs—a second PSU is optional
NEBS compliant model available, x900-24XT-N
Two high-speed bays to support a combination of expansion modules:
• XEM-1XP, 1 x 10 GbE XFP port
• XEM-2XP, 2 x 10GbE XFP ports (when running the AlliedWare Plus operating system)
• XEM-12S, 12 x SFP ports
• XEM-12T, 12 x RJ-45 ports
• XEM-STK, 2 stacking ports (when running the AlliedWare Plus operating system) x900-24XT front panel x900-24XT
Advanced L3 Switch
13
ASYN0/CONS
x900-24XS switch
Key features are:
■ Autonegotiating, multi-layer gigabit switch
■
■
■
■
■
24 1000BASE-X SFP ports
Out-of-band 10/100/1000BASE-T Ethernet management port
Optional Secure Digital memory card
Supports dual, hot-swappable, load sharing PSUs—a second PSU is optional
Two high-speed bays to support a combination of expansion modules:
• XEM-1XP, 1 x 10 GbE XFP port
• XEM-2XP, 2 x 10GbE XFP ports (when running the AlliedWare Plus operating system)
• XEM-12S, 12 x SFP ports
• XEM-12T, 12 x RJ-45 ports
• XEM-STK, 2 stacking ports (when running the AlliedWare Plus operating system) x900-24XS front panel
Advanced L3 Switch
ASYN0/CONS
C613-03092-00 REV J
14 x900 Series Switch and SwitchBlade
®
x908
SwitchBlade x908
Key features are:
■
■
■
■
■
■
■
■
Autonegotiating, multi-layer gigabit switch
Out-of-band 10/100/1000BASE-T Ethernet management port
Optional Secure Digital memory card
Supports dual, hot-swappable, load sharing PSUs
Dual, hot-swappable chassis fans
Two fixed stacking connectors on the rear of the chassis
RoHS compliant
Eight high-speed bays to support a combination of expansion modules:
• XEM-1XP, 1 x 10 GbE XFP port
• XEM-2XP, 2 x 10 GbE XFP port
• XEM-12S, 12 x SFP ports
• XEM-12T, 12 x RJ-45 ports
• XEM-STK, 2 stacking ports
SwitchBlade x908 front panel with 8 XEMs
AT-SBx908
Enhanced L3+ Modular Switch
SD FAULT
STACKING
STAT
PORT
MASTER MEMBER
NEGOTIATING
LINK FAULT
STATUS PORT 1 PORT 2
3
SYSTEM
PSU 1 PSU 2
1
RESET
ETH0
2
CONSOLE
PORT 1
SELECT
ID
STACK
STATUS
PORT 2
STAT MASTER MEMBER NEGOTIATING PORT LINK FAULT
6 7 8
4
SwitchBlade
x908
L/A
XFP
L/A LINK ACT XFP ENABLED DISABLED FAULT
L/A
XFP
L/A LINK ACT XFP ENABLED DISABLED FAULT
C613-03092-00 REV J
Hardware Reference 15
Switch LEDs
■
■
■
■
■
■
The following LEDs report operations and faults on the x900 series switch and
SwitchBlade x908:
Fast Ethernet
RJ-45 port LEDs
The following LEDs report operations and faults on Fast Ethernet RJ-45 ports.
LED
L/A
(Link Activity)
D/C
(Duplex/Collision)
State
Green
Green flashing
Amber
Amber flashing
Green
Amber
Amber flashing
Description
A 100 Mbps link has been established.
100 Mbps activity is occurring.
A 10 Mbps link has been established.
10 Mbps activity is occurring.
The port is operating in full duplex mode.
The port is operating in half duplex mode.
Collisions are occurring.
Gigabit RJ-45 port LEDs
The following LEDs report operations and faults on Gigabit RJ-45 ports.
LED
L/A
(Link Activity)
D/C
(Duplex/Collision)
State
Green
Green flashing
Amber
Amber flashing
Green
Amber
Amber flashing
Description
A 1000 Mbps link has been established.
1000 Mbps activity is occurring.
A 10/100 Mbps link has been established.
10/100 Mbps activity is occurring.
The port is operating in full duplex mode.
The port is operating in half duplex mode.
Collisions are occurring.
XFP port LEDs
The following LEDs report operations and faults on XFP ports.
LED
L/A
(Link Activity)
XFP
State
Green
Green flashing
Green
Amber
Amber flashing
Description
An XFP transceiver is installed and a 10 Gb link has been established.
An XFP transceiver is installed and link activity is occurring.
An XFP transceiver is installed and enabled. No XFP is installed if this light is off.
An XFP transceiver is installed but not operating.
The installed XFP transceiver has a transmission fault.
C613-03092-00 REV J
16 x900 Series Switch and SwitchBlade
®
x908
SFP port LEDs
The following LEDs report operations and faults on SFP ports.
LED
L/A
(Link Activity)
SFP
State
Green
Green flashing
Off
Green
Green flashing
Amber
Amber flashing
Description
A 1000 Mbps link has been established on uplink ports on these switches:
• AT-8948
• x900-48FE
• x900-48FS
Full duplex activity is occurring at 1000 Mbps on uplink ports on these switches:
• AT-8948
• x900-48FE
• x900-48FS
An SFP is installed but a link has not been established on Uplink ports on these switches:
• AT-8948
• x900-48FE
• x900-48FS
An SFP transceiver is installed and a link has been established on:
• AT-9900 series
• x900-12XT/S
• x900-24XT
• x900-24XT-N
• x900-24XS
• x900-48FS switch ports
Not valid for uplink ports on AT-8948, x900-48FE or x900-48FS switches.
An SFP transceiver is installed and a link activity is occurring on the following:
• AT-9900 series
• x900-12XT/S
• x900-24XT
• x900-24XT-N
• x900-24XS
• x900-48FS switch ports
Not valid for uplink ports on AT-8948, x900-48FE or x900-48FS switches.
An SFP transceiver is installed but a link has not been established.
An SFP transceiver is installed but there is a transmission fault.
C613-03092-00 REV J
Hardware Reference 17
System LEDs
The following LEDs report operations and faults on the switch.
LED
PSU 1 and
PSU 2
State
Green
POWER Green
Fault
CF
Red
Off
Red
Red flashing
1 Flash
Description
The PSU is installed and supplying power to the switch. The voltage output is within specification.
One of the following:
• The PSU is installed in the switch, and a fan has failed or the PSU has exceeded its recommended temperature threshold.
• A FOM is installed in the switch and a fan has failed. Note that the SwitchBlade x908 switch does not support FOMs.
• The bay is empty. Applies to AT-8948, AT-9924Ts, x900-24XT, x900-24XT-N, and x900-24XS switches since they require a
FOM when only one PSU is installed.
• Dual PSUs are installed, but the PSU is not receiving power.
• The standby switch has been turned off.
A FOM is installed and operating at an acceptable speed.
For the AT-9924T, x900-48FE, x900-48FS, and SwitchBlade x908 switches, a blanking plate is installed.
The PSU is operating and supplying power to the switch. The voltage output is within specification. Valid for the x900-12XT/S.
The switch or management software is malfunctioning. This LED lights and then turns off after hardware initialises.
The following flash sequences indicate a hardware-related fault.
After sequences of two or more flashes, the LED stops briefly, then repeats the sequence. If multiple faults occur, the LED flashes each sequence in turn, stops briefly, then repeats the sequences.
One or more heatsink fans has failed or is operating below the recommended speed.
2 Flashes For SwitchBlade x908 switches, one or both of the chassis fans are not installed, or the fans are operating below the recommended speed.
3 Flashes For switches running the AlliedWare operating system only, models
AT-9924T, AT-9924SP, AT-9924Ts, x900-24XT, x900-24XT-N, and x900-24XS, the ability to monitor temperature and fans has failed, and it cannot report whether they are in the supported ranges.
4 Flashes For switches running the AlliedWare Plus operating system, an XEM failed to initialise or is incompatible.
6 Flashes The switch’s temperature has exceeded the recommended threshold.
Slow flashing at startup
The SDRAM (DIMM) has not been detected. Does not apply to
AT-9924Ts, x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, and SwitchBlade x908 switches.
Rapid flashing at startup
Green flashing
The SDRAM (DIMM) is not compatible with the switch. Does not apply to AT-9924Ts, x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, or SwitchBlade x908 switches.
The CompactFlash memory card is active and should not be ejected.
The card can be safely ejected when the LED remains off. Valid for
AT-8948, x900-48FE, x900-48FS, AT-9924T, and AT-9924SP switches.
C613-03092-00 REV J
18 x900 Series Switch and SwitchBlade
®
x908
LED
SD
State
Green flashing
Description (cont)
The Secure Digital memory card is active and should not be ejected.
The card can be safely ejected when the LED remains off. Valid for the AT-9924Ts, x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, and SwitchBlade x908 switches.
Stacking LEDs
The following LEDs report stacking operations and faults on the
SwitchBlade x908 switch and the XEM-STK expansion module.
LED
Port 1 and
Port 2
State
Green
Amber slow flashing
Description
A link has been established.
The link has a transmission fault.
Status numeric ID
(XEM-STK only)
Green
Amber
Green flashing
Off
1 to 8
Off
The switch is the stack master.
The switch is a stack member.
The switch is in the process of learning the stack topology and selecting the stack master.
The switch is not a stack member.
Numeric ID of the stack member.
The switch is not a stack member.
C613-03092-00 REV J
Hardware Reference 19
Management Ports
■
■
The following management ports let you configure, monitor, and upgrade the switch:
Out-of-Band Ethernet Management Port
5
6
3
4
7
8
Pin
1
2
RS-232 Terminal Port
The RS-232 ASYN0/CONSOLE port is standard for the x900 series switches and SwitchBlade x908, and connects them to a management device for initial configuration. This port allows the software on the switch to be accessed from a terminal or a PC running terminal emulation software.
The ASYN0/CONSOLE port has an RJ-45 socket with an industry recognised pinout. This requires using a straight-through RJ-45 cable with an RJ-45 DB9 connector when the switch is connected to a terminal or PC. The socket is wired as a DTE and the pin layout is shown in the following table. Pins a re numbered from right to left
Role
RTS
DTR (DSR and DTR are connected but have no other internal connection)
TXD
GND
GND
RXD
DSR (DTR and DSR are connected but have no other internal connection)
CTS
Out-of-Band Ethernet Management Port
■
■
The out-of-band 10/100/1000 Mbps Ethernet port (Eth0) is dedicated to management traffic on the following switches:
■ AT-9924Ts
■ x900-12XT/S x900-24X series
SwitchBlade x908
Use the management port for initial configuration and on-going management tasks. For remote access, use the default IP address, 192.168.242.242. This port is reserved for management only; the switch does not transmit frames between this port and switch ports.
On the SwitchBlade x908, the management port can also be used to create a stack resiliency link when the switch is part of a virtual chassis stack. For more information about resiliency links, see the Stacking Introduction chapter of the
AlliedWare Plus™ Operating System Software Reference.
C613-03092-00 REV J
20 x900 Series Switch and SwitchBlade
®
x908
Network Ports
■
■
■
■
The following ports are on the switches and XEMs:
SFP Ports
SFP transceivers are compact, hot-swappable, and high speed. Different fibre and copper SFP transceivers are supported so that you can interchange port types to meet changing network requirements. SFP transceivers must be purchased separately. For the latest list of approved SFP transceivers, contact your authorised Allied Telesis distributor or reseller.
Speed and duplex modes
Speed and duplex settings differ depending on the type of SFP transceiver installed in the port.
The following table shows supported speeds for copper and fibre SFPs.
Port Type
AT-8948 uplink ports x900-48FE uplink ports x900-48FE-N uplink ports x900-48FS uplink ports x900-48FS switch ports
AT-9924T switch ports
AT-9924SP switch ports x900-12XT/S combo ports x900-24XS switch ports
XEM-12S switch ports
1000
9
9
9
9
9
9
9
9
9
Copper (Mbps)
100
9
9
9
9
10
9
9
9
9
Fibre (Mbps)
1000
9
9
9
9
9
9
9
9
9
100
9
9
9
9
9
1
1. Requires M4 revision of hardware. Use the show system command to check the hardware revision level.
The following table shows supported duplex and autonegotiation options for copper and fibre SFPs.
Port Type
AT-8948 uplink ports x900-48FE uplink ports x900-48FE-N uplink ports x900-48FS uplink ports
Copper autonegotiate
1000 Mbps half/full duplex autonegotiate
1000 Mbps half/full duplex autonegotiate
1000 Mbps half/full duplex autonegotiate
1000 Mbps half/full duplex
Fibre autonegotiate
1000 Mbps full duplex autonegotiate
1000 Mbps full duplex autonegotiate
1000 Mbps full duplex autonegotiate
1000 Mbps full duplex
C613-03092-00 REV J
Hardware Reference 21
Port Type (cont) x900-48FS switch ports
AT-9924T switch ports
AT-9924SP switch ports x900-12XT/S combo ports x900-24XS switch ports
XEM-12S switch ports
Copper (cont) n/a autonegotiate
10 Mbps half/full duplex
100 Mbps half/full duplex
1000 Mbps half/full duplex autonegotiate
10 Mbps half/full duplex
100 Mbps half/full duplex
1000 Mbps half/full duplex autonegotiate
1000 Mbps half/full duplex autonegotiate
10 Mbps half/full duplex
100 Mbps half/full duplex
1000 Mbps half/full duplex autonegotiate
1000 Mbps half/full duplex
Fibre (cont) no autonegotiation
100 Mbps half/full duplex autonegotiate
1000 Mbps full duplex no autonegotiation
100 Mbps half/full duplex autonegotiate
1000 Mbps full duplex autonegotiate
100 Mbps half/full duplex
1000 Mbps half/full duplex no autonegotiation
100 Mbps half/full duplex autonegotiate
1000 Mbps full duplex autonegotiate
100 Mbps half/full duplex
1000 Mbps half/full duplex
An error message is displayed when an SFP port cannot operate at the specified speed or duplex mode.
When using SFP ports 1 to 4 on AT-9924T switches, the corresponding RJ-45 ports (1 to 4) are disabled. However, when the SFP transceiver is removed, the
RJ-45 port becomes operational again.
Inserting and removing an
SFP transceiver
The SFP transceiver must be inserted the correct way in the socket, which varies depending on whether the switch has a single or dual row of sockets.
For example, x900-48FE switches have single-row sockets, but AT-9900 series switches have a dual row. See the example of dual-row sockets for a copper SFP transceiver in the figure below. Notice the varying position of the release lever.
Warning Do not look into SFP cables or transceivers. Even disconnected fibres and connectors can emit invisible laser radiation.
C613-03092-00 REV J
22 x900 Series Switch and SwitchBlade
®
x908
SFP Transceiver
Release Lever
Slide the transceiver into the SFP socket, and firmly press it until it engages. To remove it, first release it by gently pulling the release lever, and then pull the transceiver out of the socket. Never force a transceiver into or out of a socket.
Note that the above illustration does not show the correct orientation for an
SFP transceiver for insertion into an SFP socket in the top row of SFP sockets shown. The illustration shows the correct orientation for an SFP transceiver for insertion into an SFP socket in the lower row of SFP sockets shown.
C613-03092-00 REV J
Hardware Reference 23
XFP Ports
XFPs are approved for use with the AT-A60 and XEM-1XP and XEM-2XP expansion modules. XEM-2XP is only supported on Allied Telesis switches running the AlliedWare Plus operating system. XFPs must be purchased separately. For the latest list of approved XFPs, contact your authorised Allied
Telesis distributor or reseller. The AT-A60 is supported on the AT-9924Ts switch. The XEM-1 XP and XEM-2XP are supported on the x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, and SwitchBlade x908 switches.
■
■
■
■
RJ-45 Ports
The following devices have RJ-45 ports:
AT-8948 and x900-48FE switches
AT-9924T, AT-9924T, and x900-24XT switches
AT-A62 expansion module for the AT-9924Ts switch
XEM-12T expansion module for the x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, and SwitchBlade x908 switches
■
■
These ports feature the following:
■ gigabit ports that support speeds of 10/100/1000 Mbps
■ status LEDs
Separate packet buffer memory cable fault detection and distance-to-fault diagnostics are available on switches running the AlliedWare operating system (see the Test Facility chapter in the AlliedWare
®
Operating System Software Reference for the switch)
Stacking Ports
■
■
The x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, and SwitchBlade x908 switches support the XEM-STK virtual chassis stacking module which features:
■ two high-speed stacking connections
■
LEDs showing port and stack member status numeric display identifying status of stack members
Select button to reset the stack ID of the switch to 1
The SwitchBlade x908 switch also has two fixed stacking ports on its rear panel, which feature:
■ two high-speed stacking connections
■ LEDs showing port and stack member status
C613-03092-00 REV J
24 x900 Series Switch and SwitchBlade
®
x908
Expansion Options
Optional expansion modules make the AT-9924Ts, x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, and SwitchBlade x908 switches some of the most flexible units available. They provide economical combinations of speed and port density.
■
■
The AT-9924Ts supports the following expansion modules:
■
AT-A60, 1 x 10 GbE XFP port
AT-A61, 12 x SFP ports
AT-A62, 12 x RJ-45 ports
■
■
The x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, and SwitchBlade x908 switches support:
■ XEM-1XP, 1 x 10 GbE XFP port
■
■
XEM-2XP, 2 x 10GbE XFP ports (when running the AlliedWare Plus operating system)
XEM-12S, 12 x SFP ports
XEM-12T, 12 x RJ-45 ports
XEM-STK, 2 stacking ports (when running the AlliedWare Plus operating system)
For more information about AT-A6x expansion modules, see the AT-9900s
Series Switch Expansion Module Installation Guide.
For more information about XEM expansion modules, see the x900 Series
Switch and SwitchBlade
®
x908 Expansion Module Installation Guide.
For the latest list of approved transceiver modules, contact your authorised
Allied Telesis distributor or reseller.
C613-03092-00 REV J
Hardware Reference 25
Memory Options
■
■
The following memory expansion options are available:
■
Dual In-line Memory Module (DIMM)
CompactFlash Card
■
■
■
■
CompactFlash (CFlash) cards are a memory expansion option for the following switches running the AlliedWare operating system:
■ AT-8948 x900-48FE x900-48FS
AT-9924T
AT-9924SP
Data such as releases, patches, and configurations can be stored on these cards, and files can be manipulated with the command line interface (CLI). However, release and patch files cannot be run directly from the card, but must be loaded into either NVS or on-board flash.
Important Anyone with a compliant reader can read CFlash cards so do not keep sensitive data on them.
Approved
CFlash card
The CompactFlash card approved for the x900-48FE, x900-48FS, and AT-9900 series switches is AT-CF128A-00 128 MBytes. Other cards are unlikely to work with the switch.
Inserting and removing a
CFlash card
You can insert the card into the CompactFlash slot at any time; it takes about two seconds to initialise. The following CLI message confirms that the card has been inserted:
Info (1106257): Compact flash card inserted.
The following message confirms that the card is ready to use:
Info (1106268): Compact flash card initialisation successful.
The following message means that the CFlash card is not compatible with the switch:
Info (3106300): Compact flash card initialisation unsuccessful.
Important When data is being written to or read from the card, the CF LED on the front panel of the switch is green. Do not remove the card when it is active or you will corrupt the data. Wait until the LED is off before ejecting the card.
Displaying data about a CFlash card
To display information about a CompactFlash card, including card size, file count, and serial number, insert the card and enter the command: show cflash
To display cluster ranges on a card, insert the card and enter the command: show cflash test
C613-03092-00 REV J
26 x900 Series Switch and SwitchBlade
®
x908
The following figure is an example of output from the show cflash test command when no test is running.
Clusters available for testing
Ranges:
[42645--61944]
Number of free clusters = 19300
Number of ranges = 1
Number of used clusters = 42645
Testing a CFlash card
It is important to fully test the hardware interface of the switch to the CFlash card. This test consists of reading vendor information and reading and writing to every part of the card.
To test the card, insert it in the CF slot and enter the command: enable cflash test start=startnumber end=endnumber where startnumber and endnumber are positive integers within a cluster range.
The end number must be higher than the start number. Cluster ranges are displayed in the output of the show cflash test command.
The test software reads the file allocation table and displays a list of free sectors. Sectors can be tested as single sectors or as a range. The test consists of a write/read/verify cycle.
To stop the test, use the disable cflash test command. To display test results while a test is in process, enter the show cflash test command. Also, use this command when testing is not active to display the blank clusters range on the card.
The following is example output from the show cflash test command when a test is running.
Test Progress
Starting cluster = 700
Ending cluster = 1700
Current cluster = 1185
Passed clusters number = 485
Passed sectors number = 1940
Failed clusters number = 0
Failed sectors number = 0
Used Clusters encountered = 0
Duration................ 4417 ms
Error messages are displayed when a file write fails. Failure could be because of the card being removed or an error in the card itself. For more information about these test commands and others for CFlash, see the Managing the File
System chapter in the AlliedWare
®
Operating System Software Reference.
C613-03092-00 REV J
Hardware Reference 27
Secure Digital (SD) Card
■
■
■
■
Secure Digital cards are a memory expansion option for the following switches:
■ AT-9924Ts x900-12XT/S x900-24XT
■ x900-24XT-N x900-24XS
SwitchBlade x908
Data such as releases and configurations can be stored on SD cards, and files can be manipulated with the command line interface (CLI). On switches running the AlliedWare Plus operating system, you can boot from an SD card using the Bootloader menu. However, under normal operating conditions you cannot run release or package files directly from the SD card; they must be loaded into NVS or on-board flash.
SD cards are smaller than CompactFlash cards and have a large storage capacity. Switches accept most SD cards with various capacities up to 2 GBytes.
Be sure to verify operation before attempting to store data.
Important Do not keep sensitive data on SD cards because anyone with a compliant reader can read them.
Inserting and removing an SD card
You can insert a card into the SD slot at any time. Just push the card into the slot until you feel it latch.
When data is being written to or read from the card, the SD LED on the front panel of the switch flashes green. Do not remove the card when it is active or you will corrupt the data being read or written, and may corrupt other data on the card. Wait until the LED remains off before releasing the card. To remove the card, use a press-and-release action. Avoid touching the metal contacts.
To safeguard the data, store the card immediately in its case or somewhere away from heat, humidity, or dust. Do not store it near electrostatic, electromagnetic, magnetic or radioactive fields. If necessary, clean with a soft dry cloth.
Displaying data about an SD card
To display information about an SD card, such as card size, file count, and volume label, insert the card.
On switches running the AlliedWare operating system, use the command: show card
The following figure is an example of output from the show card command.
Volume label ......... SD_512
Files total size ..... 13367336 bytes (30 files)
Used space ........... 13434880 bytes
Free space ........... 497754112 bytes
Total space .......... 511188992 bytes
You can also use the show card command to verify whether the switch recognises the card. For more information about this command, see the
C613-03092-00 REV J
28 x900 Series Switch and SwitchBlade
®
x908
Managing the File System chapter in the AlliedWare
®
Operating System Software
Reference.
On switches running the AlliedWare Plus operating system, use the commands: awplus#show file systems awplus#dir card:/
Testing the slot
On switches running the AlliedWare operating system, you can test the SD card slot on front of the switch to verify that the hardware does the following:
■ detects the presence of a card
■
■
■ detects whether a card has been exchanged detects write-protection on a card transfers data to and from a card
The test does not write data to the card or harm existing data. To test the slot, use the command: enable test device=card type=slot
Output is sent to the management asynchronous port. For more information about testing the card slot, see the Test Facility chapter in the AlliedWare
®
Operating System Software Reference.
C613-03092-00 REV J
Hardware Reference 29
Dual In-line Memory Module (DIMM)
Synchronous DRAM (SDRAM) is provided by a single DIMM. Only DIMMs supplied by Allied Telesis have been tested and approved for use. Using unapproved DIMMs may cause unreliable operation and will invalidate the warranty for the switch .
The following SDRAM options are supported:
■ AT-8948, x900-48FE, x900-48FS, AT-9924T, and AT-9924SP switches ship with 256 MBytes of SDRAM, expandable to 512 MBytes with a DIMM.
■
■
AT-9924Ts, x900-12XT/S, x900-24XT, x900-24XT-N, and x900-24XS switches are shipped with a 512 MBytes of DDR SDRAM, no upgrades are available.
SwitchBlade x908 switches are shipped with a 512 MBytes DDR SDRAM
SODIMM. The SODIMM memory is not interchangable with the DIMM memory in other switches.
Warning Only authorised service personnel should install DIMMs. Opening the switch’s lid may cause personal injury from electric shock and could damage the switch.
Verifying DIMM installation
The switch is unlikely to boot unless the DIMM is correctly installed. You will not be able to issue any diagnostic commands, and will have to rely solely on
LED fault codes.
If the switch boots up but you suspect the DIMM is malfunctioning, display
system information by using the show system command. See “Verifying installation” on page 40
for output.
The size of SDRAM is in the memory section of the output. If the SDRAM size is less than the size of DIMM that has been installed, then the switch has not detected the DIMM. The most likely cause is that the DIMM connector is not correctly plugged into the slot.
Record the switch’s serial number and revision details for later reference. If you have questions or problems with the DIMM at any time, contact your authorised Allied Telesis distributor or reseller and supply these serial numbers.
C613-03092-00 REV J
30 x900 Series Switch and SwitchBlade
®
x908
Cables
■
■
■
■
This section describes the following:
RS-232 Terminal and Modem Cables
Cables for RJ-45 Ethernet LAN Interfaces
■
RJ-45 to DB9 female terminal cable
RS-232 Terminal and Modem Cables
The terminal and modem cables described in this section are:
■ RS-232 RJ-45 to DB9 female terminal cable
■ DCE RS-232 terminal port RJ-45 to DB9 male modem cable
Figures in this section show pin wiring diagrams to connect a standard VT100 compatible terminal or modem to ASYN0.
RJ-45
(to switch)
5
2
8
1
6
7
4
3
DB9 Female
(to terminal)
1
2
3
4
5
6
7
8
9 not connected
Note
This cable supplied as part number C855-84903-00.
Now at version B.
RJ45DB9F_x900
C613-03092-00 REV J
Hardware Reference
RJ-45 to DB9 male modem cable
31
RJ-45
(to switch)
1
8
7
6
3
2
5
4 not connected
Note
Cable version 1.0
DB9 Male
(to modem)
1
2
3
4
5
6 not connected
7
8
9 not connected
RJ45DB9M_x900
For more information on pin assignments for the RS-232 port, see “RS-232
Cables for RJ-45 Ethernet LAN Interfaces
A twisted pair cable with four pairs and RJ-45 connectors must be used for
10BASE-T/100BASE-TX/1000BASE-T connections.
Caution Do not plug a phone jack into an RJ-45 switch port because you could damage the switch. Use only twisted pair cables with RJ-45 connectors.
Pin assignments
Each pair of twisted pair cables is identified by related colours. For example, one wire might be red and the related wire would be red-and-white stripe. An
RJ-45 connector must be fitted to both ends of the cable. The following diagram shows RJ-45 connectors and the pin layout.
1
1
8
1 rjpin
C613-03092-00 REV J
32 x900 Series Switch and SwitchBlade
®
x908
1000BASE straight-through cable
For 1000BASE network connections, all four pairs are used and the cable is wired in a straight-through configuration. You can use this cable with the software test facility to test 1000BASE network ports. The following table lists pin assignments for a 10/100/1000BASE-T RJ-45 four pair straight-through cable.
5
7
8
6
4
2
3
End 1
Pin
1
Pair
Pair 1+
Pair 1-
Pair 2+
Pair 2-
Pair 3+
Pair 3-
Pair 4+
Pair 4-
5
7
8
6
4
2
3
End 2
Pin
1
Pair
Pair 1+
Pair 1-
Pair 2+
Pair 2-
Pair 3+
Pair 3-
Pair 4+
Pair 4-
1000BASE crossover cable
For 1000BASE test cables, all four pairs are used and the cable is wired in either a crossover or straight-through configuration. The following table lists pin assignments for a 10/100/1000BASE-T RJ-45 four pair crossover cable.
3
6
4
5
7
8
1
2
End 1
Pin Pair
Pair 1+
Pair 1-
Pair 2+
Pair 2-
Pair 3+
Pair 3-
Pair 4+
Pair 4-
3
6
4
5
7
8
1
2
End 2
Pin Pair
Pair 2+
Pair 2-
Pair 1+
Pair 1-
Pair 4+
Pair 4-
Pair 3+
Pair 3-
Cables for Stacking
Cables for virtual chassis stacking using the XEM-STK expansion module or the rear panel stacking connectors on the SwitchBlade x908 must be purchased separately from your authorised Allied Telesis distributor or reseller. See
for a list of part numbers.
C613-03092-00 REV J
Hardware Reference 33
Cable Guidelines
The following table lists port, connector, and cable combinations for switches and expansion modules.
Switch / Expansion module Port Type
AT-8948 x900-48FE x900-48FE-N
10BASE-T /
100BASE-TX
AT-9924T
AT-9924Ts x900-12XT/S x900-24XT x900-24XT-N
AT-A62
XEM-12 T
10BASE-T /
100BASE-TX /
1000BASE-T x900-48FS 100BASE-X
Connector Type
RJ-45
RJ-45
Varies with SFP
Cable Type
1
CAT5
CAT5
CAT5
CAT5E
Max Cable Length
100 m Max
120 m Max
100 m Max
120 m Max
100 m Max
Refer to documentation with
SFP
Refer to documentation with
SFP
Refer to documentation with
SFP
Refer to documentation with
SFP
AT-8948 x900-48FE x900-48FE-N x900-48FS
AT-9924T
AT-9924SP
AT-A61 x900-12XT/S x900-24XS
XEM-12 S
AT-A60
XEM-1 XP
XEM-2XP
1000BASE-X
10GBASE
Varies with SFP
XEM-STK
SwitchBlade x908
Stacking
Stacking
PCIe x8
PCIe x16
1. Refer to the IEEE Standard 802.3 for additional cable information
Refer to documentation with
XFP
Refer to documentation with
XFP
AT-XEM-STK-CBL0.5
AT-XEM-STK-CBL2.0
0.5 m
2.0 m
AT-HS-STK-CBL1.0
1.0 m
C613-03092-00 REV J
34 x900 Series Switch and SwitchBlade
®
x908
Troubleshooting Cables
Cable test
The virtual cable test facility diagnoses cable faults and the approximate distance to them on Gigabit Ethernet RJ-45 ports for the following switches running the AlliedWare operating system:
■
■
■
■
AT-9924T x900-24XT x900-24XT-N x900-24XS
See “Test Facility” on page 57
for more information or the Test Facility chapter in the AlliedWare
®
Operating System Software Reference. Not all copper SFPs support this feature; however, those listed in
do support it.
The virtual cable test facility is not supported in the AlliedWare Plus operating system.
Cable lengths
Approximate cable lengths are reported for gigabit Ethernet RJ-45 ports on the following switches running the AlliedWare operating system:
■ AT-9924T
■
■
■ x900-24XT x900-24XT-N x900-24XS
■
■
■
■
Cable length is reported after the link is established. To check the length, use the show switch port command described in the Switching chapter in the
AlliedWare
®
Operating System Software Reference. The Cable Length parameter in the output of this command can be one of the following values:
■ <50m
■
50–80m
80–110m
110–140m
>140m
- (either the port link is down, or the port is operating at 10 Mbps or
100 Mbps)
Cable length reporting is not supported in the AlliedWare Plus operating system.
C613-03092-00 REV J
Hardware Reference 35
Power Supply Units (PSUs) and Fans
Depending on the model, single or dual PSUs can be fitted on the rear of the switch, as either AC or DC. Some models also have fan-only modules (FOM) and chassis fans.
Model
AT-8948 x900-48FE x900-48FS
AT-9924T
AT-9924SP
Description
Supports 1 PSU and 1 FOM, or 2 PSUs.
A second PSU is available for optional redundancy. When two are fitted, they must be the same type of current, either AC or DC.
When there is just one PSU in an AT-9900 series switch, it must be in
Bay 2 for optimised cooling.
x900-12XT/S
AT-9924Ts x900-24XT x900-24XS
Supports 1 fixed PSU.
Supports 1 PSU and 1 FOM, or 2 PSUs.
A second PSU is available for optional redundancy.
SwitchBlade x908 Supports 2 System PSUs and 2 chassis fan modules.
AT-PWR01
AT-PWR02
AT-PWR05
AT-FAN01
AT-FAN03
AC or DC power supply unit.
AC power supply unit.
AC or DC power supply unit.
Fan-only module (FOM).
Chassis fan module.
Each PSU and FOM contains an EPROM chip that contains information, such as the type of module, serial number, and revision of the PSU. This information is available through the command line interface (CLI).
How to install a PSU or fan in the switch is described in the Removable Power
Supply and Fan Installation Guide.
PSU and FOM installed in an x900-24XT switch
PSUs and chassis fans installed in a SwitchBlade x908
SYSTEM PSU 1:
AC 100-240V 50/60Hz 9A MAX
DC 40-60V 20A MAX
AT-FAN03
FAULT
FAN 1
SYSTEM PSU 2:
AC 100-240V 50/60Hz 9A MAX
DC 40-60V 20A MAX
CAUTION: DISCONNECT
POWER CORD PRIOR
TO REMOVAL OF PSU
CAUTION: DISCONNECT ALL
POWER CORDS TO DISABLE
SYSTEM POWER
STACKING PORT 1
FOR CENTRALISED
DC POWER
CONNECTION,
INSTALL ONLY IN A
RESTRICTED ACCESS
LOCATION
STACKING PORT 2
C613-03092-00 REV J
AT-FAN03
FAULT
FAN 2
36 x900 Series Switch and SwitchBlade
®
x908
Approved PSUs and fans
The following table shows which models of PSUs and fans are appropriate for individual switches.
Switch
AT-8948 x900-48FE x900-48FS
AT-9924T
AT-9924SP
AT-9924Ts x900-24XT x900-24XS
PWR01
9
9
9
9
9
9
9
PWR02
9
PWR05 FAN01
9
9
9
9
9
9
9
9
FAN03
SwitchBlade x908
9 9
PWR01 AC and
DC PSUs
■
■
■
■
Key features are:
Hot-swappable and load sharing
Physical dimensions
• Height: 40.9 mm
• Width: 193 mm
• Depth: 130 mm
Do not combine AC and DC PSUs in the same switch.
Do not combine PWR01 and PWR02 PSUs in the same switch.
■
■
AC model:
Universal 100–240 V AC 47/63 Hz input
Maximum continuous current draw: 3.0 A at 230 V at full-rated load
■
■
Maximum inrush surge current (cold start at 25º C/77º F): 70 A at 240 V, 32 A at 115 V
Fuse rating for FH101 and FH102: 250 V, 5 A
Warning Double pole/neutral fusing. Electric shock is possible since there are dual primary fuses, one on the phase circuit and one on the neutral circuit. If the neutral opens, the phase may still be live.
■
■
■
■
DC model:
40 V to 60 V, 48 V nominal
Supports either positive grounded or negative grounded operation
■
Maximum continuous current draw: 3.9 A at 40 V
Maximum standby current: 100 mA
Run/Standby switch
The following LEDs report operations and faults on the PWR01 PSU.
LED
PWR
State
Green
Description
A PSU is installed in the switch and is delivering power.
C613-03092-00 REV J
Hardware Reference 37
LED
Fault
State
Red
Description
There is either a fan failure, or the temperature has exceeded its limit of 70º C (158º F).
PWR02 AC PSU
Key features are:
■ Hot-swappable and load sharing
■ Physical dimensions
■
■
■
■
• Height: 40.9 mm
• Width: 193 mm
• Depth: 130 mm
Do not combine PWR01 and PWR02 PSUs in the same switch.
Universal 100–240 V AC 47/63 Hz input
Maximum continuous current draw: 2.2 A at 100 V, 1.1 A at 230 V at fullrated load
Maximum inrush surge current (cold start at 25º C/77º F): 33 A at 115 V
The following LEDs report operations and faults on the PWR02 PSU.
LED
PWR
Fault
State
Green
Red
Description
A PSU is installed in the switch and is delivering power.
There is either a fan failure, or the temperature has exceeded its limit of 70º C (158º F).
PWR05 AC and DC
PSUs
Key features are:
■ Hot-swappable and load sharing
■ Physical dimensions
• Height: 40.6 mm
• Width: 83.8 mm
• Depth: 298.2 mm
AC model
■ Universal 100–240 V AC 50/60 Hz input
■
■
Maximum continuous current draw: 9 A at 85 V, 3.3 A at 230 V at full-rated load
Maximum inrush surge current (cold start at 25º C/77º F): 34 A peak at
230 V
■
■
■
■
DC model
40V to 60V DC, 48V nominal
Supports either positive grounded or negative grounded operation
■
Maximum continuous current draw: 20A max at 40V DC
Maximum standby current: 300 mA
Run/Standby switch
C613-03092-00 REV J
38 x900 Series Switch and SwitchBlade
®
x908
The following LEDs report operations and faults on the PWR05 PSU
The following table describes LEDs on the PWR05 AC power supply unit.
IN
LED
~
OUT
FAULT
State
Green
Off
Green
Off
Red
Off
Description
AC input voltage is within 90-264 VAC, 47-63Hz.
AC input voltage is outside the acceptable range.
DC output voltage is within 12V +/- 10%.
DC output voltage is outside the acceptable range, or the Standby switch is Off. If a fault occurs then the FAULT LED will display and the OUT LED will be Off.
A fault has occurred. There is either a fan failure, or the temperature has exceeded its limit of 70º C (158º F).
No fault conditions detected.
The following table describes LEDs on the PWR05 DC power supply units.
LED
IN
OUT
FAULT
State
Green
Off
Green
Off
Red
Off
Description
DC input voltage is within 40 VDC to 60 VDC.
DC input voltage is outside the acceptable range.
DC output voltage is within 12V +/- 10%.
DC output voltage is outside the acceptable range, or the Standby switch is Off. If a fault occurs then the FAULT LED will display and the OUT LED will be Off.
A fault has occurred. There is either a fan failure, or the temperature has exceeded its limit of 70º C (158º F).
No fault conditions detected.
x900-12XT/S fixed AC PSU
Key features are:
■ Universal 100–240 V AC 50/60 Hz input
■
■
Maximum continuous current draw: 2 A at 90 V, 0.8 A at 230 V at full-rated load
Maximum inrush surge current (cold start at 25º C/77º F): 33 A peak at
115 VAC
A single LED on the front panel of the switch reports operations and faults on the PSU. See
“System LEDs” on page 17 for more information.
IPv6 Accelerator Card
An optional AT-ACC01 network processor accelerator card accelerates IPv6 unicast and multicast routing in hardware on AT-8948 switches. For full functionality, 512 MBytes SDRAM must be installed in the switch.
How the card works
When the switch receives an IPv6 packet to route, the packet is sent to the network processor accelerator card. The card processes the packet and sends it out the correct port with appropriate alterations to the packet. Other IPv6 functions are passed to software, such as routing protocol control packets, encryption, authentication, and hop-by-hop headers.
C613-03092-00 REV J
Hardware Reference 39
No configuration is necessary for the accelerator card to function; the card is enabled at installation. If you disable the card (using software), the switch handles IPv6 routing in the software.
Use the hardware filter and QoS commands to enable Quality of Service (QoS) functionality on the accelerator card. For information about QoS functionality and hardware filters, see the Quality of Service and Switching chapters in the
Software Reference.
Warning Only authorised service personnel should install a network processor accelerator card. Opening the switch’s lid may cause personal injury from electric shock, could damage the switch, and will invalidate the product warranty.
C613-03092-00 REV J
40 x900 Series Switch and SwitchBlade
®
x908
Verifying installation
To confirm that the network processor accelerator card is installed and operating correctly, check that the switch has recognised it. Turn on the switch and enter the show system command to display system information. The following figure is an example of output from the show system command for the AT-8948 model.
Switch System Status Time 14:50:14 Date 18-Apr-2007
Board ID Bay Board Name Host Id Rev Serial number
------------------------------------------------------------
Base 201 AT-8948 0 P4-3 58823566
Accel 214 AT-ACC01 0 M1-1 61101175
PSU 212 1 AT-PWR01-AC 0 P3-0 58494001
------------------------------------------------------------
Memory - DRAM :131072 kB FLASH : 32768 kB
------------------------------------------------------------
SysDescription
Allied Telesis AT-8948 version 2.8.1-06 30-Jan-2007
SysContact
SysLocation
SysName
SysDistName
SysUpTime
26588 ( 00:04:25 )
Boot Image : 89_120.fbr size 1038496 30-May-2006
Software Version: 2.8.1-06 30-Jan-2007
Release Version : 2.8.1-00 23-Jun-2006
Patch Installed : NONE
Territory : europe
Country : none
Help File : help.hlp
PSU1: (AC) Fan: Normal Temp: Normal Power: Normal
Current temperature : Normal
Current accelerator card temperature: Normal
FAN
-----------------
Main fan Normal
Accelerator fan 1 Normal
Accelerator fan 2 Normal
-----------------
Configuration
Boot configuration file: flash:boot.cfg (exists)
Current configuration: flash:boot.cfg
Security Mode : Disabled
The first section of the output shows information about boards installed in the switch. There are details about the switch base card, the accelerator card if installed, and the type of power supply unit or fan-only module. Both the part names and serial numbers of the base card and accelerator card are displayed.
Record the details of the base card and the network processor accelerator card for later reference. If you have questions or problems with the network
C613-03092-00 REV J
Hardware Reference 41 processor accelerator card at any time, contact your authorised Allied Telesis distributor or reseller and supply the serial numbers for them.
If there is no entry for the accelerator card, then the switch’s boot process has not detected the card. The most likely cause is that the card is incorrectly plugged into the slot on the switch’s base board.
Displaying information about the card
To display information about the status and memory of a network processor accelerator card on AT-8948 switch, use the show switch accelerator command.
The following figure is an example of output from the show switch accelerator command.
Switch Accelerator Configuration
--------------------------------------------------
Hardware Type .............. AT-ACC01
Mode ....................... IPv6 Acceleration
Status ..................... IPv6 active
Search memory size ......... 128 Mb
Counter memory size ........ 2 Mb
--------------------------------------------------
C613-03092-00 REV J
42 x900 Series Switch and SwitchBlade
®
x908
Using AT-TFTP Server
This section explains how to access and use the AT-TFTP Server. You can transfer configuration files as well as download software upgrades with
AT-TFTP Server.
1.
If AT-TFTP Server has not been installed, install it now. You can download it from www.alliedtelesis.com/support/software/ .
Select AT-TFTP Server from the Start > Programs > Allied Telesis >
AT-TFTP Server menu.
2.
To set preferences for the AT-TFTP Server, select Options from the File menu to display the Set Options dialog box.
• Default file transfer directories: one or more directories that AT-TFTP
Server will read from or write to, for requests that do not include a directory specification. Separate multiple directories with semi-colons
(“;”).
• Restrict to directories: To prevent unauthorised access to private directories, AT-TFTP Server will only use these directories, even if requests explicitly reference other directories. Separate multiple directories with semi-colons (“;”).
• Read Only/Read Write: For added security, select “Read only” to prevent AT-TFTP Server writing files to the PC. If you wish to use the
PC to archive scripts created using the create config command, you must enable the “Read Write” option.
C613-03092-00 REV J
Hardware Reference 43
• Diagnostic Messages: Check “Diagnostics Messages” to display additional diagnostic messages in the AT-TFTP Server window when debugging file transfers.
• IPv4 and IPv6: Choose whether AT-TFTP Server should respond to
TFTP requests received via IPv4 only, IPv6 only, or both IPv4 and IPv6.
• Firewall mode: select “RFC Compliant Mode” to allow multiple files to be transferred simultaneously, or “Firewall Friendly” to force all TFTP traffic to use port 69 as either the source or destination port. This will only allow one file to be transferred at a time.
• Click the OK button when you finish.
3.
To download a file from AT-TFTP Server:
On switches running the AlliedWare
®
operating system, at the command line interface type the following command: load method=tftp file=filename server=ipadd dest=flash
On switches running the AlliedWare Plus™ operating system, enter
Privileged Exec mode and enter the command: awplus#copy tftp://ipadd/filename flash
filename is the name of the file to download and ipadd is the IP address of the
PC running AT-TFTP Server.
4.
TFTP requests are logged to the AT-TFTP Server main window. To save a
TFTP Server log, select Save As from the File menu.
C613-03092-00 REV J
44 x900 Series Switch and SwitchBlade
®
x908
Using Windows Terminal and
HyperTerminal
You can use a PC running terminal emulation software as the manager console, instead of a terminal. There are many terminal emulation applications available for PCs, but the most readily available are the Terminal and
HyperTerminal applications included in Microsoft Windows 98, 2000, and
XP Professional. In standard Windows installations, HyperTerminal is available from the Communications submenu.
The key to successful use of terminal emulation software with the switch is to configure the software and switch with matching communications parameters.
The following procedure can be applied to most terminal emulation programs.
Dialog boxes in the procedure are from Windows 2000 and XP Professional.
To configure Windows HyperTerminal for 2000 and XP Professional
1.
Start the program in Windows by doing one of the following:
• Select Programs > Accessories > Communications > HyperTerminal.
• Double-click the Hypertrm.exe icon.
2.
In the Connection Description dialog box:
• Enter a name for the connection, such as Admin.
• Select an icon from the scrollable list and click the OK button.
C613-03092-00 REV J
Hardware Reference 45
3.
In the “Connect using” field on the Connect To dialog box, select the COM port on the PC used to connect to the switch. and click the OK button.
4.
In the COMn Properties dialog box, set the port to 9600 bits per second, 8 data bits, no parity, and 1 stop bit.
• For switches running the AlliedWare
®
operating system, set the flow control to Hardware.
• For switches running the AlliedWare Plus™ operating system, set the flow control to None.
Click the OK button.
C613-03092-00 REV J
46 x900 Series Switch and SwitchBlade
®
x908
5.
From the main HyperTerminal window, select Properties from the File menu. Click the Settings tab, and set the Properties dialog box as follows.
6.
Click ASCII Setup to display the ASCII Setup dialog box, and ensure the following options are not selected:
• Echo typed characters locally
• Append line feeds to incoming line ends
Set other parameters as necessary and click the OK buttons on both dialog boxes to close them.
C613-03092-00 REV J
Hardware Reference 47
7.
Save the current session by selecting Save from the File menu on the main
HyperTerminal window. This creates a connection icon with the name you assigned in the HyperTerminal group.
To use the configuration, double-click the connection icon. When the
HyperTerminal window appears, press the Enter key several times; the switch’s login prompt is then displayed.
C613-03092-00 REV J
48 x900 Series Switch and SwitchBlade
®
x908
How the Switch Starts Up
When the switch starts up following a power cycle or an operator-initiated reboot (using the reset button or restart command), it performs a series of tests and sends messages to the terminal or PC connected to the ASYN0/CONSOLE port. After the switch successfully starts, a prompt is displayed for you to log in. Refer to the x900 Series Switch and SwitchBlade
®
x908 Installation and Safety
Guide for basic login instructions.
■
■
The startup sequence, messages, and options varies depending on the switch and the operating system:
■
“AlliedWare Plus Operating System Startup” on page 48
“AlliedWare Operating System Startup on AT-9924Ts, x900-24XT, and x900-24XS Switches” on page 48
AlliedWare Plus Operating System Startup
The startup sequence for x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, and SwitchBlade x908 switches running the AlliedWare Plus operating system is described in detail in the Startup Sequence chapter of the AlliedWare Plus™
Operating System Software Reference.
AlliedWare Operating System Startup on
AT-9924Ts, x900-24XT, and x900-24XS Switches
This section explains how AT-9924Ts, x900-24XT, x900-24XT-N, and x900-24XS switches start initially, including error messages. The following types of software play key roles during startup.
Software
Base
Fallback
Description
Product software that is typically the “preferred” base package installed. It constitutes a feature set—similar to a “release”—and runs the switch. A software licence must be enabled for specific base packages.
A small subset of the base package that runs when the base package is unavailable. It can download and install a base package, modify configuration scripts, and monitor the system.
Bootloader Software that runs the switch when it first powers up. It performs basic initialisation, provides a basic interface for hardware diagnostics, and executes either the base or fallback software.
Process flow
When the switch starts, it performs the following operations.
Stage This happens...
1 Self-tests run that check basic operations.
2
3
A prompt is displayed briefly to allow a user-override. Users can change the startup process by pressing special keys (see
Overrides ). If they enter nothing, the process continues.
Product software or fallback software is executed, depending on what the user installed.
Done by...
Bootloader
Bootloader
Bootloader
C613-03092-00 REV J
Hardware Reference
Stage This happens...
4
5
Hardware boards and software components are initialised.
The startup configuration script that the user specified is executed.
6 Startup is complete and the switch starts switching traffic if devices connected to it are sending traffic.
Done by...
Base or Fallback
Base or Fallback
Base
49
Overrides
The switch pauses briefly during startup messages to display the following prompt:
Boot fallback software (Y)?
If you do nothing, the installed base package is loaded along with a preconfigured startup script. For troubleshooting, change the process by using the following keys.
Pressing this key... Forces the switch to...
Y Load the fallback software instead of the base package.
S (skip)
Ctrl+B
Load the base package and skip the startup configuration script.
Display a bootloader prompt. To upgrade a bootloader file, load the new .bin file into the file system, and enter the command:
Ctrl+D copy filename.bin bootloader
For information about the load command, see the Managing
Configuration Files and Software Versions chapter in the Software
Reference.
Enter diagnostics mode. For more information, see
Regular output
AlliedWare operating system bootloader and product software display a series of messages similar to those in the following figure during routine startup.
------------------------------------------------------------
Bootloader v3-00, built 6 Mar 2006
------------------------------------------------------------
Identifying RAM .................................. 512 MB
Initial RAM test ................................. passed
Relocating the bootloader to execute from RAM .... done
Boot fallback software (Y) ?
Initialising file system access .................. done
Booting preferred base package: AT9924s_311-00.pkg
Installing system.img (1775093 bytes) ............ done
Initiating system software ....................... done
------------------------------------------------------------
AlliedWare v3.1.1-00, built 23 Jun 2006
------------------------------------------------------------
Initialising file system access .................. done
Validating package licence ....................... done
Installing product_apps.img (9705444 bytes) ...... done
Executing configuration script <startup.cfg>
Switch startup complete
C613-03092-00 REV J
50 x900 Series Switch and SwitchBlade
®
x908
Fallback output
Fallback software is a subset of the base package and runs when the base package is unavailable. When the switch runs fallback software, a series of messages similar to those in the following figure are displayed.
. .
. (bootloader messages) .
. .
Booting fallback software
Installing system.img (1219098 bytes) ............ done
Initiating system software ...................... done
------------------------------------------------------------
AlliedWare Fallback v3.1.1-00, built 7 Jun 2006
------------------------------------------------------------
WARNING: Fallback software will not allow normal
network operation
Initialising file system access .................. done
Installing product_apps.img (1646897 bytes) ...... done
Executing configuration script <startup.cfg>
Switch startup complete
Bootloader messages
The following table explains messages that bootloader software displays at initial startup.
Message
Bootloader <version>, built
<date>
Identifying RAM...512 MB or
Identifying RAM...failed
Initial RAM test...passed
or
Initial RAM test...failed
Relocating the bootloader to execute from
RAM...done
or
Relocating the bootloader to execute from
RAM...failed
Description
Banner that identifies the bootloader software.
The switch contains the amount of memory indicated. If memory identification fails, the switch displays a brief description of the failure and pauses indefinitely. Contact your authorised distributor or reseller.
Whether initial RAM tests are successful. If tests detect a problem with DRAM, the switch cannot be used. Contact your authorised distributor or reseller.
Whether bootloader software is successfully running from
RAM instead of flash memory. If not successful, the system pauses indefinitely; contact your authorised distributor or reseller.
Boot fallback software (Y) ?
Prompt that lets you override the standard startup sequence, typically when troubleshooting.
If you press Y, the switch boots from fallback software, and a confirmation message is displayed. For more information, see fallback output.
Initialising file system access...done
or
Initialising file system access...failed
Whether bootloader software has initialised access to the file system.
Failure means a problem with the file system or memory device. The switch reformats memory and processing continues but data will have been lost. Contact your authorised distributor or reseller.
C613-03092-00 REV J
Hardware Reference 51
Message
Booting install-type
filename.pkg.
Installing system.img
<bytes>...done
or
Installing system.img
<bytes>...failed
Initiating system software...done
or
Initiating system software...failed
Description (cont)
Name of the software package to be installed: preferred base package, temporary base package, or fallback. For information about types of install, see “Install Process” in the Managing Configuration Files and Software Versions chapter in the Software Reference.
Whether the system software image of the given size is successfully installed in RAM and able to execute.This image is extracted from the installed package.
If this fails when booting from a base package, the switch goes to the fallback software.
If this file cannot be extracted from the fallback package, there may be a problem with fallback; contact your authorised distributor or reseller.
Whether bootloader software has initiated execution of product software or fallback software, whichever the user selected, and is shifting control to it. If not successful, the system pauses indefinitely; contact your authorised distributor or reseller.
Bootloader Error Messages
The base package has a problem that prevents it from starting up. The switch starts up the fallback software.
WARNING: Base package start-up failed too many times
WARNING: Fallback start-up failed too many times
ERROR: Fallback area is corrupt - launching the bootloader CLI
ERROR: No main board personality - launching the bootloader CLI
No valid installed package - booting fallback software
ERROR: No valid software available - launching the bootloader CLI
ERROR: Package
filename.pkg is not valid
ERROR: ELF header has problem
The fallback software has a problem that prevents it from starting up. The switch shifts to bootloader software and displays a bootloader prompt. Contact your authorised distributor or reseller before proceeding.
The switch is shifting to bootloader software because the fallback area in flash is unformatted or corrupt. It displays a bootloader prompt. Contact your authorised distributor or reseller before proceeding.
Unique information about the main PCB has not been programmed and the switch cannot start without it. Contact your authorised distributor or reseller.
The switch cannot find valid installed software, or files with install information are corrupt and the fallback area does not contain a valid file. The switch starts from fallback software.
See the Managing Configuration Files and Software Versions chapter in the Software Reference for information about installation procedures, including the set install command.
The switch is shifting to bootloader software because it cannot find a valid package. It displays a bootloader prompt.
Contact your authorised distributor or reseller before proceeding.
The switch could not extract the system image file because of a problem with the given package. Install a different package from fallback. Contact your authorised distributor or reseller if the problem continues.
The system image file is corrupt or invalid for the reason given.The switch tries to start from fallback software. If this fails, contact your authorised distributor or reseller.
C613-03092-00 REV J
52 x900 Series Switch and SwitchBlade
®
x908
Message
ERROR: System image has no section headers
ERROR: No memory available for storing ELF element
Description (cont)
The system image file is corrupt or invalid because it has no section header information. Contact your authorised distributor or reseller.
A serious problem exists with memory allocation software or memory on the switch. Contact your authorised distributor or reseller.
AlliedWare operating system messages
The following table explains messages that the base and fallback software display at startup.
Message
Alliedware <version>, built
<date>
Description
Banner that identifies the product software the switch is executing—base or fallback.
WARNING: Fallback software will not allow normal network operation
Initialising file system access...done
or
Initialising file system access...failed
Validating package licence...done
or
Validating package licence...failed
Installing product_apps.img
<bytes>...done
or
Installing product_apps.img
< bytes>...failed
When starting from fallback software, a reminder that fallback is a subset of the product software and does not have its full functionality.
Product software has initialised access to the file system.
Failure means a problem with the file system or flash.
Processing will continue but data will be lost. Contact your authorised distributor or reseller.
Whether a valid licence has been found for the base package.
Verify licence, version, and switch model and contact your authorised distributor or reseller if necessary. Not displayed for fallback.
IGMP packet trapping has been activated for IGMP snooping
Executing configuration script <startup.cfg>
Whether the product application image of the given size is installed in RAM and able to execute. This file is part of the installed package.
Failure could mean not enough RAM or the package is corrupt. Contact your authorised distributor or reseller.
IGMP packet trapping is enabled to allow IGMP snooping to function. A warning is displayed if this function could not be activated. Not displayed for fallback.
Configuration commands in the given script file begin executing if selected by the user. If the script has an error, appropriate error messages are displayed.
Switch startup complete The startup process is complete and the switch is ready. If devices connected to it are sending traffic, then the switch begins switching operations.
AlliedWare Operating System Error Messages
ERROR: Phase 1 of Software
Manager startup failed - rebooting
Software Manager is part of the system software that controls startup of the product software. It failed to complete the first phase of its initialisation and cannot boot the fallback software. Manually restart the switch with fallback
software (for details, see “Overrides” on page 49 ).
If this error occurs while rebooting from fallback, contact your authorised distributor or reseller.
C613-03092-00 REV J
Hardware Reference 53
Message
WARNING: Bad board of type <number> in
Expansion Bay <number>
WARNING: Unsupported board of type <number> in
Expansion Bay <number>
Unit was rebooted because of a system exception
Creating core file system_release-
number.core...done
or
Creating core file system_release-
number.core...failed
ERROR: Unable to read fallback package information
ERROR: Unable to read preferred or temporary install information
ERROR: Failed to extract product_apps.img from package to RAM
Description (cont)
Board personality of the given type in the given bay could not be read. Possible causes include:
• unprogrammed personality PROM on the board
• faulty hardware on expansion or host board
For information about boards, see the show system boards command in the Configuring and Monitoring the System chapter in the Software Reference.
Software does not support the board of the given type in the given bay.
The switch is restarting after a system exception. Depending on the exception, you may need to contact your authorised distributor or reseller.
Displayed after the switch restarts itself, and indicates whether system core information has been written to the specified file. Each image file creates its own core file and coredump. This information is loaded into RAM after a system exception and before the switch restarts. Contact your authorised distributor or reseller.
Information about fallback software is not available. Contact your authorised distributor or reseller.
ERROR: Failed to run product_apps.img
ERROR: Phase 2 of Software
Manager startup failed - rebooting to fallback software
Information is not available about the type of install indicated. The switch tries to start from fallback software. If this fails, contact your authorised distributor or reseller.
The product application image could not be extracted from the package file because the package file is corrupt or there is not enough RAM.
Manually restart the switch with fallback software (for details, see
), and install another base package.
If this error occurs while rebooting from fallback, contact your authorised distributor or reseller.
The operating system could not execute the product application image file.
Manually restart the switch with fallback software (for details, see
), and install another base package.
If this error occurs while rebooting from fallback, contact your authorised distributor or reseller.
Software Manager is part of the system software that controls startup of the product software.The install information for it is invalid or the installed software is not licenced. Therefore, the switch boots up from the fallback software.
C613-03092-00 REV J
54 x900 Series Switch and SwitchBlade
®
x908
AlliedWare Operating System Startup on
AT-8948, x900-48FE, x900-48FS, and AT-9900
Switches
Process flow
When the AT-8948, x900-48FE, x900-48FS, or AT-9900 switches start, they perform the following operations.
3
4
Stage This happens...
1 Self-tests run that check basic operations.
2 A prompt is displayed briefly to allow a user-override. Users can change the startup process by pressing special keys (see
). If they enter nothing, the process continues.
5
6
The flash boot release is loaded as the install software.
Install information is checked and the switch boots up from either the preferred or default install.
The startup configuration script that the user specified is executed.
Startup is complete and the switch starts switching traffic if devices connected to it are sending traffic.
Done by...
Boot ROM
Boot ROM
Boot ROM
Boot ROM
Preferred or default software
Release software
Overrides
The switch pauses briefly during routine startup messages to display the following prompt:
Force EPROM download (Y)?
If you do nothing, switch software is loaded along with a preconfigured startup script. For troubleshooting, change the process by using the following keys.
Pressing this key... Forces the switch to...
Y Load the flash boot release with no patch.
S
Ctrl+D
Start with the default configuration so that any boot script is ignored.
Enter diagnostics mode. For more information, see “Diagnostics” on page 58 .
Regular output
The following messages are an example of output from the AT-8948, x900-48FE, x900-48FS, and AT-9900 series switches.
INFO: Self tests beginning.
INFO: RAM test beginning.
PASS: RAM test, 131072k bytes found.
INFO: BBR tests beginning.
PASS: BBR test, 512k bytes found.
INFO: Self tests complete
INFO: Downloading switch software.
Force EPROM download (Y) ?
INFO: Initial download succeeded
INFO: Executing configuration script <boot.cfg>
INFO: Switch startup complete
C613-03092-00 REV J
Hardware Reference 55
Types of messages
The following table explains the types of messages that the AT-8948, x900-48FE, x900-48FS, and AT-9900 series switches generate during initial startup.
Type
INFO
PASS
ERROR
FAIL
Description
An action has been taken by the system.
A test has been completed successfully.
An error message that a test has failed but the system continues to operate.
An error message that a fatal error condition has caused the system to halt in an unrecoverable fashion.
AlliedWare operating system messages
The following table explains messages in the output of the AT-8948, x900-48FE, x900-48FS, and AT-9900 series switches.
Message
INFO: Self tests beginning.
INFO: RAM tests beginning
PASS: RAM test, 131072k bytes found
Description
Code loader tests are about to begin.
RAM tests are about to begin.
RAM test passed and the switch is using the indicated amount of memory.
ERROR: RAM test test-number.
Error address = address
For example:
ERROR: RAM test 5. Error address = 00345678
The given RAM test failed at the given address, which means the memory system is faulty. The test repeats until it passes. If the error continues, contact your authorised distributor or reseller.
INFO: BBR tests beginning
PASS: BBR test. Battery OK
ERROR: BBR Battery low
BBR battery tests are about to begin.
BBR battery tests passed.
PASS: BBR test, 512k bytes found
FAIL: BBR test. Error address = location
BBR battery test failed, indicating that the battery is running low. The BBR battery must be replaced. Contact your authorised Allied Telesis distributor or reseller.
BBR size/location test passed with the indicated amount of
BBR found.
FAIL: BBR test, only 16k bytes found
BBR size/location test failed at the given location. The test at this location failed, indicating the end of memory, but a valid location was discovered in the 255 long words following this location. The BBR system must be replaced.
Contact your authorised distributor or reseller.
The BBR size/location test completed, but only the displayed amount of memory was found. This amount is less than the minimum required to run the switch software.
INFO: Self tests complete
INFO: Downloading switch software
Startup tests have finished.
The process of downloading the switch software and vector table from ROM is about to begin.
ERROR: Code load retried
FAIL: Code load failed
Loading code from ROM to RAM failed. The load is retried a number of times, and the error message is displayed each time it fails. The fail message is displayed if the switch reaches the maximum number of attempts.
Force EPROM download (Y) ?
Prompt that lets you override the standard startup sequence, typically when troubleshooting.
C613-03092-00 REV J
56 x900 Series Switch and SwitchBlade
®
x908
Message
INFO: Initial download succeeded
INFO: Downloading compressed release. This may take up to 1 minute...
INFO: Loading software into memory. This may take up to 1 minute...
Description (cont)
Startup tests and download are complete, and the switch software is about to be started.The release is now decompressed. This may take a few seconds.
The main switch software is decompressed before being loaded into RAM.
INFO: Executing configuration script <script-name>
Configuration commands in the given script file begin executing if selected by the user. If the script has an error, appropriate error messages are displayed.
INFO: Switch startup complete The startup process is complete and the switch is ready. If devices connected to it are sending traffic, then the switch begins switching operations.
C613-03092-00 REV J
Hardware Reference
Test Facility
The test facility is a hardware test tool in the AlliedWare operating system. Its primary function is to validate that there are no hardware problems after installation of the switch or expansion options. You can also use it as a troubleshooting tool, but it is just one of many such tools. You could consider the test facility to be a specialised interface module, such as PPP or Frame
Relay, where the interfaces under test are dedicated to the test facility.
Before you use the test facility, disable configurations by using the set configuration=none command, and restart or reboot the switch. For more information about the test facility, see the Test Facility chapter in the
AlliedWare
®
Operating System Software Reference.
57
Testing Ethernet LAN Ports
A crossover cable is required to run an Ethernet LAN test. How to make a
between two RJ-45 ports and enter the enable test interface=all command.
Interfaces connected by crossover cables are tested. If a test fails, contact your authorised Allied Telesis distributor or reseller.
To display test results, use the show test command. To display detailed output with frame counts, use the show test count command. For example output from these commands, see the Test Facility chapter in the AlliedWare
®
Operating
System Software Reference. This chapter also contains information on how to test other interfaces.
C613-03092-00 REV J
58 x900 Series Switch and SwitchBlade
®
x908
Diagnostics
The AlliedWare and AlliedWare Plus operating systems include a set of diagnostic programs that perform basic checks of all system components.
These diagnostics do not run with normal operating code and require that the system be totally dedicated to their use. The switch does not perform switching operations when diagnostics are running.
This section describes the diagnostics available in the AlliedWare operating system. For information about diagnostics available in the AlliedWare Plus operating system, see the Startup Sequence chapter of the AlliedWare Plus™
Operating System Software Reference.
Caution Diagnostics are designed to be run by service personnel only. This section is not intended as a guide to diagnostics software. Detailed knowledge of how the switch hardware functions is necessary in order to effectively use diagnostic programs. For more information, contact your authorised Allied
Telesis distributor or reseller.
Enabling diagnostics mode
1.
Connect a terminal to the RS-232 terminal port.
Use a terminal cable to connect a terminal to the RS-232 port (ASYN0/
CONSOLE) on the switch. For more information on terminal cables, see
“RS-232 Terminal and Modem Cables” on page 30 .
Set the terminal communication parameters as follows:
• Baud rate: 9600
• Data bits: 8
• Parity: None
• Stop bits: 1
• Flow control: Hardware
For more information, see
“Using Windows Terminal and HyperTerminal” on page 44 .
2.
Restart the switch.
To restart the switch, use a small diameter pin to press the recessed Reset button on the front panel of the switch. You can also log in at the terminal and enter the command: restart reboot
How to log in is described in the Installation and Safety Guide.
3.
Enable diagnostics mode during self-tests at startup.
The switch pauses briefly during its self-tests to allow an override.
For the AT-8948, x900-48FE, x900-48FS, and AT-9900 series switches, the following prompt is displayed:
Force EPROM download (Y)?
For AT-9924Ts, x900-24XT, x900-24XT-N, and x900-24XS switches, the following prompt is displayed:
Boot fallback software (Y)?
Press Ctrl+D to enable diagnostics mode. Press Ctrl+D just once to ensure you send no other characters to the switch.
C613-03092-00 REV J
Hardware Reference 59
One of the following menus is displayed depending on the switch model.
When you see the menu, you know that the terminal is connected.
Menu for AT-8948, x900-48FE, x900-48FS, and AT-9900 series switches.
* * * Diagnostic Mode * * *
version: Nov 10 2005 11:08:34
Main Menu:
0. Restart
1. Full RAM test
2. ROM checksum test
5. Battery backed RAM test
7. Display PCI devices (not shown for x900-48FE switches)
8. Watchdog test (not shown for x900-48FE switches)
Enter selection ==>
Caution If you have an EPROM chip and you perform a full flash test or erase flash, you will delete all configuration and release files. We recommend that you know how to reload these files before you erase flash or perform a flash test.
Menu for AT-9924Ts, x900-24XT, x900-24XT-N, and x900-24XS switches.
Diagnostics Menu:
0. Restart
1. Full RAM test
2. Bootloader ROM checksum test
3. Full FLASH test
4. Erase FLASH file system
5. Battery backed RAM (NVS) test
6. Quick RAM test
7. PCI bus search
8. Quit and continue booting
Enter selection ==>
Caution If you perform a full flash test or erase flash, you will delete all configuration files and the product software that runs the switch. We recommend that you know how to reload these files before you erase flash or perform a flash test.
Running a diagnostic program
There are several sub-menus that cover the available options. Control keys for diagnostic operations are in the following table.
Key
Q
S
Function
Quits tests that are running. Displays a banner page or restarts, depending on the switch.
Prints a summary of test results thus far for AT-9900 series switches only.
To restore the switch to normal operation, use a small diameter pin to press the recessed reset button on the front panel of the switch, or press 0 to restart.
C613-03092-00 REV J
60 x900 Series Switch and SwitchBlade
®
x908
Troubleshooting
■
■
This section provides information on how to troubleshoot the x900 series switch and SwitchBlade x908 to resolve the following basic problems:
■
What to check first
■ Check power cord connections.
■
■
■
■
■
Check that the power supply voltage is stable.
Check that the correct data cables are used and that their connections are secure.
Make sure that other network devices work properly.
Check that the latest software release is loaded. The Software Reference describes how to obtain the latest software release.
• On switches running the AlliedWare operating system, use the show install command.
• On switches running the AlliedWare Plus operating system, use the show version command.
If the switch malfunctions, reboot it using one of the following methods:
• use a small diameter pin to operate the recessed Reset button on the switch’s front panel
• shut down and restart the switch at the main power source (AC models) or use the Run/Standby switch on the PSU (DC models).
• On switches running the AlliedWare operating system, use the restart reboot command.
• On switches running the AlliedWare Plus operating system, use the reload command.
L/A LED on a port is off
■
■
■
■
If the Link/Activity LED is off, it may indicate the following: a loose data cable the device at the other end of the connection does not work properly or is turned off
■ the data cable is not wired correctly the network administrator has manually disabled the port through the software the port’s selected transmission mode does not match that of the attached device
Follow these suggestions to resolve the problem:
1.
Make sure the data cable connections are secure.
2.
Make sure the device at the other end of the connection is powered on and works properly.
3.
Check that the data cable is wired correctly.
4.
If you can, log in and check the port status. How to log in is described in the x900 Series Switch and SwitchBlade
®
x908 Installation and Safety Guide.
C613-03092-00 REV J
Hardware Reference 61
5.
If the port is enabled, make sure the transmission speed matches that of the connected device (autonegotiating, full or half-duplex).
6.
If the port is disabled, someone disabled it with the software. Find out why before you enable it.
Power LED is off
If the power LED is off, it may indicate the following:
■
■
■ a loose power cord a power supply failure a FOM is installed in that bay
Follow these suggestions to resolve the problem:
1.
Check that the power cord connections are secure.
2.
Check that all switches and circuit protection devices are in the “on” position.
3.
Ensure that the supply voltage is within the operational range. See “Power
Supply Units (PSUs) and Fans” on page 35 .
Fault LED is on
If the fault LED is on, it may indicate the following:
■ there is a problem with the switch
■
■ the switch or management software is malfunctioning a hardware fault is preventing switch startup
Follow these suggestions to resolve the problem:
1.
Read the descriptions of LED flashing sequences for explanations of what to do (see
2.
Reset the switch. Use a small diameter pin to press the recessed reset button on the front panel of the switch.
3.
If you were attempting to download software or manage the switch over the
RS-232 terminal port, check that connections between the terminal port and local terminal or PC are secure.
If you cannot access the switch software because of a faulty RS-232 terminal port connection, you can still manage the switch by using Telnet or SNMP until the problem is resolved.
4.
Download the most current software. The Software Reference describes how to obtain the latest software product.
Additional resources
■ www.alliedtelesis.com/support/software
■ the Test Facility chapter in the AlliedWare
®
Operating System Software
Reference
■ How To notes from www.alliedtelesis.co.uk/en-gb/solutions/ techdocs.asp
C613-03092-00 REV J
62 x900 Series Switch and SwitchBlade
®
x908
Obtaining Documentation and Resources
The complete document set for x900 Series switches and SwitchBlade x908 includes:
■
■ this Hardware Reference, which contains detailed information on the switch and its hardware features the x900 Series Switch and SwitchBlade
®
x908 Installation and Safety Guide, which describes how to install the switch and includes important safety and statutory information
■
■
■
■
■ the Removable Power Supply and Fan Installation Guide, which describes how to install power supply units and fan-only modules in the switch the x900 Series Switch and SwitchBlade
®
x908 Expansion Module Installation
Guide, which describes how to install expansion modules in x900 Series and SwitchBlade x908 switches the AT-9900s Series Switch Expansion Module Installation Guide, which describes how to install expansion modules in AT-9900s Series switches the x900 Series Switch AlliedWare
®
Operating System Software Reference, which contains detailed information on configuring switches running the
AlliedWare operating system the AlliedWare Plus™ Operating System Software Reference, which contains detailed information on configuring switches running the AlliedWare Plus operating system
You can download these documents and updates from www.alliedtelesis.com/support/software .
You need Adobe
®
Acrobat
®
Reader
®
software to view, search, or print these documents. You can download it from www.adobe.com
.
Other resources
How-To Notes describe a range of standard Allied Telesis solutions, and include technical tips and guides to configuring specific hardware and software features. You can download the latest How-To Notes from www.alliedtelesis.com/resources/literature/howto.aspx
.
MIBs supported by Allied Telesis products can be downloaded from www.alliedtelesis.com/support/software .
Microsoft
®
Visio
®
stencils for Allied Telesis products can be downloaded from www.alliedtelesis.com/resources/images/visio.aspx
.
AT-TFTP Server for Windows is a TFTP (Trivial File Transfer Protocol) server for transferring software versions, configuration scripts and other files between a
PC and the switch. You download AT-TFTP Server from www.alliedtelesis.com/support/software .
CD-ROM
Some products ship with a Documentation and Tools CD-ROM, which includes:
■
■
■ the complete document set
Adobe
®
Acrobat
®
Reader
®
AT-TFTP Server
■
■
Supported MIBs
How-To Notes, white papers, Microsoft
®
Visio
®
stencils and other resources
C613-03092-00 REV J
Hardware Reference 63
■ Tryouts of networking software
Contacting us
With locations covering all of the established markets in North America, Latin
America, Europe, Asia, and the Pacific, Allied Telesis provides localized sales and technical support worldwide. To find the representative nearest you, visit us on the Web at www.alliedtelesis.com
.
C613-03092-00 REV J
64 x900 Series Switch and SwitchBlade
®
x908
C613-03092-00 REV J
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Key Features
- Managed L3+ Web-based management
- Quality of Service (QoS) support
- Basic switching RJ-45 Ethernet ports quantity: 24
- 1U
Related manuals
advertisement
Table of contents
- 6 Devices Covered by this Document
- 7 48-Port Fast Ethernet Switches
- 7 Dimensions
- 7 Mounting system
- 7 Asynchronous serial port
- 7 Environmental conditions
- 7 Regulatory standards
- 7 Switching core
- 8 Processing core
- 8 IPv6 accelerator card
- 8 AT-8948 and x900-48FE switches
- 8 x900-48FS switch
- 9 Gigabit Switches
- 9 Dimensions
- 9 Mounting system
- 9 Asynchronous serial port
- 9 Environmental conditions
- 9 Regulatory standards
- 9 Switching core
- 9 Processing core
- 10 AT-9924T switch
- 10 AT-9924SP switch
- 11 Expandable Gigabit Switches
- 11 Dimensions
- 11 Mounting system
- 12 Asynchronous serial port
- 12 Environmental conditions
- 12 Regulatory standards
- 12 Switching core
- 12 Processing core
- 13 AT-9924Ts switch
- 13 x900-12XT/S switch
- 14 x900-24XT switch
- 14 x900-24XS switch
- 15 SwitchBlade x
- 16 Switch LEDs
- 16 Fast Ethernet RJ-45 port LEDs
- 16 Gigabit RJ-45 port LEDs
- 16 XFP port LEDs
- 17 SFP port LEDs
- 18 System LEDs
- 19 Stacking LEDs
- 20 Management Ports
- 20 RS-232 Terminal Port
- 20 Out-of-Band Ethernet Management Port
- 21 Network Ports
- 21 SFP Ports
- 24 XFP Ports
- 24 RJ-45 Ports
- 24 Stacking Ports
- 25 Expansion Options
- 26 Memory Options
- 26 CompactFlash Card
- 28 Secure Digital (SD) Card
- 30 Dual In-line Memory Module (DIMM)
- 31 Cables
- 31 RS-232 Terminal and Modem Cables
- 32 Cables for RJ-45 Ethernet LAN Interfaces
- 33 Cables for Stacking
- 34 Cable Guidelines
- 35 Troubleshooting Cables
- 35 Cable test
- 35 Cable lengths
- 36 Power Supply Units (PSUs) and Fans
- 37 PWR01 AC and DC PSUs
- 38 PWR02 AC PSU
- 38 PWR05 AC and DC PSUs
- 39 x900-12XT/S fixed AC PSU
- 39 IPv6 Accelerator Card
- 39 How the card works
- 41 Verifying installation
- 42 Displaying information about the card
- 43 Using AT-TFTP Server
- 45 Using Windows Terminal and HyperTerminal
- 49 How the Switch Starts Up
- 49 AlliedWare Plus Operating System Startup
- 49 and x900-24XS Switches
- 55 x900-48FS, and AT-9900 Switches
- 58 Test Facility
- 58 Testing Ethernet LAN Ports
- 59 Diagnostics
- 59 Enabling diagnostics mode
- 60 Running a diagnostic program
- 61 Troubleshooting
- 61 What to check first
- 61 L/A LED on a port is off
- 62 Power LED is off
- 62 Fault LED is on
- 62 Additional resources
- 63 Obtaining Documentation and Resources
- 63 Other resources
- 63 CD-ROM
- 64 Contacting us