Juniper Networks M40e, M160 Internet Routers Installation Instructions
Below you will find brief information for M40e and M160. This document provides detailed instructions for removing and replacing the Connector Interface Panel (CIP) on Juniper Networks M40e and M160 Internet routers. It covers the CIP's description, including Routing Engine interface ports, BITS input ports, and alarm relay contacts, along with necessary tools and procedures for installation, removal, and cable replacement.
Advertisement
Advertisement
M40e and M160 CIP Installation Instructions Part No. 530-005365-01 Revision 2 23 January 2002 This document describes how to remove and replace the Connector Interface Panel (CIP) on a Juniper Networks M40e Internet router or M160 Internet router. For additional installation and configuration information, see the following documentation: M40e Internet Router Hardware Guide M160 Internet Router Hardware Installation Guide JUNOS Internet Software Operational Mode Command Reference JUNOS Internet software configuration guides Contents CIP Description .....................................................................................................................1 Routing Engine Interface Ports.......................................................................................3 BITS Input Ports .............................................................................................................4 Alarm Relay Contacts.....................................................................................................5 Tools and Parts Required ......................................................................................................5 Replace the CIP .....................................................................................................................5 Remove the CIP .............................................................................................................5 Install the CIP.................................................................................................................7 Replace Cables and Wire Connecting to the CIP....................................................................8 Replace the Management Ethernet Cable.......................................................................9 Replace the Console or Auxiliary Cable ........................................................................10 Replace Alarm Relay Wire............................................................................................11 Contact Juniper Networks....................................................................................................11 CIP Description The Connector Interface Panel (CIP) is located at the left side of the FPC card cage. Figure 1 shows an M40e router, and the location of the CIP and other components is the same on teh M160 router. The CIP houses interface connectors and alarm relay contacts, shown in Figure 2 and described in the following sections: Routing Engine Interface Ports on page 3 BITS Input Ports on page 4 Alarm Relay Contacts on page 5 M40e and M160 CIP Installation Instructions • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 1 CIP Description • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Figure 1: Front of Chassis 2 M40e and M160 CIP Installation Instructions Center rack-mounting ear Front support posts Craft interface R FPCs CIP ESD point Air filter 1900 Cable management system CIP Description Figure 2: Connector Interface Panel HOST 0 ETHERNET ACT 0 YEL = 10M GRN = 100M CONSOLE AUXILLARY Routing Engine ports HOST 1 ETHERNET ACT 1 YEL = 10M GRN = 100M CONSOLE AUXILLARY BITS A LINK BITS B BITS input ports LINK RED ALARM NC C Alarm relay contacts NO NC C NO 1204 YELLOW ALARM Routing Engine Interface Ports On the upper half of the CIP are two sets of ports for connecting the Routing Engines to one or more external devices on which system operators can issue JUNOS command-line interface (CLI) commands to manage the router. The set of ports labeled HOST0 connects to the Routing Engine in the slot labeled RE0, and the set labeled HOST1 connects to the Routing Engine in the slot labeled RE1. The ports in each set are labeled as follows: ETHERNET—Connects the Routing Engine through an Ethernet connection to a management LAN (or any other device that plugs into an Ethernet connection) for out-of-band management. The port uses an autosensing RJ-45 connector to support both 10- and 100-Mbps connections. Two small LEDs on the left edge of the port indicate the connection in use: the amber LED lights for a 10-Mbps connection and the green LED lights for a 100-Mbps connection. CONSOLE—Connects the Routing Engine to a system console through an RS-232 (EIA-232) serial cable. AUXILIARY—Connects the Routing Engine to a laptop, modem, or other auxiliary device through an RS-232 (EIA-232) serial cable. M40e and M160 CIP Installation Instructions • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 3 CIP Description 4 Figure 3 shows the ports that connect to the Routing Engine installed in slot RE0. The arrangement of ports for the Routing Engine installed in slot RE1 is the same. Figure 3: Interface Ports for Routing Engine 0 HOST 0 ETHERNET ACT Ethernet port Ethernet LEDs YEL=10Mb GRN=100Mb Console port CONSOLE Auxiliary port 1236 AUXILIARY BITS Input Ports In the center of the CIP are two ports labeled BITS A and BITS B (see Figure 4). The router does not support BITS input, so these ports do not function. Figure 4: Alarm Relay Contacts and BITS Input Ports BITS A LINK BITS input ports BITS B LINK RED ALARM NC C NO Alarm relay contacts NC C NO YELLOW ALARM 1173 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • M40e and M160 CIP Installation Instructions Tools and Parts Required Alarm Relay Contacts At the bottom of the CIP are two relay contacts for connecting the router to external alarm-reporting devices, the upper labeled RED ALARM and the lower YELLOW ALARM (see Figure 4). A system condition that causes either the red or yellow alarm LED to light on the craft interface also activates the corresponding alarm relay contact. For instructions for attaching a device to the alarm relay contacts, see “Replace Alarm Relay Wire” on page 11. Tools and Parts Required To replace the CIP, you need the following tools and parts: Phillips (+) screwdriver, numbers 1 and 2 ESD grounding wrist strap Electrostatic bag or antistatic mat 2.5 mm flat-blade (–) screwdriver, for alarm relay terminal block Wire cutters, if attaching to an external alarm-reporting device Replace the CIP The CIP is located to the left side of the FPC card cage, as shown in Figure 1. It weighs about 6.5 lb (3 kg). The CIP is field-replaceable, but you must power down the router before removing or installing it. To replace the CIP, perform the following procedures: Remove the CIP on page 5 Install the CIP on page 7 Remove the CIP To remove the CIP, follow this procedure: 1. Place an electrostatic bag or antistatic mat on a flat, stable surface to receive the CIP. 2. Attach an ESD strap to your bare wrist and connect the strap to one of the ESD points on the chassis. 3. On the console or other management device connected to each Routing Engine, enter CLI operational mode and issue the following command to shut down the router software. For more information, see the JUNOS Internet Software Operational Mode Command Reference. user@host> request system halt Wait to continue until a message appears on the console confirming that the operating system has halted. M40e and M160 CIP Installation Instructions • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 5 Replace the CIP 6 4. Power down the router: On an M160 router or a DC-powered M40e router, flip both circuit breaker switches on the circuit breaker box to the OFF (O) position. On an AC-powered M40e router, flip the circuit breaker switch on both power supply faceplates to the OFF (O) position. 5. Disconnect any external devices connected to the CIP. For more information, see “Replace Cables and Wire Connecting to the CIP” on page 8. 6. Using a Phillips screwdriver, loosen and remove the screws at the top and bottom of the CIP faceplate. 7. Grasp the CIP and slide it out of the chassis (see Figure 5, which shows an M40e router). Place it in the electrostatic bag or on the antistatic mat prepared in Step 1. Be sure to slide the CIP straight out of the slot to avoid damaging the connecting pins on the front of the midplane. Figure 5: Remove the CIP R 1924 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • M40e and M160 CIP Installation Instructions Replace the CIP Install the CIP To install the CIP, follow this procedure: 1. Verify that the router is powered down. 2. Carefully insert the rear of the CIP into the guides at the top and bottom of the CIP slot located to the left of the FPC card cage (see Figure 6, which shows an M40e router). The components on the CIP are on the left side of the board, unlike the components of an FPC, which are on the right side. Verify that the components are on the left before inserting the CIP. 3. Slide the CIP into the chassis until it contacts the midplane. Be sure to slide the CIP straight into the slot to avoid damaging the connecting pins on the front of the midplane. 4. Using a Phillips screwdriver, tighten the screws on the top and bottom of the CIP faceplate. 5. Reattach any external devices connected to the CIP. For instructions, see “Replace Cables and Wire Connecting to the CIP” on page 8. 6. Turn on the power to the management device that is connected to the Routing Engine through the CIP port labeled CONSOLE, AUXILIARY, or ETHERNET. 7. Flip one circuit breaker switch to the ON ( | ) position (on the faceplate of one power supply on an AC-powered M40e router or on the circuit breaker box of an M160 router or DC-powered M40e router). Observe the LEDs on the power supply faceplate: On a properly functioning AC power supply, the green OUTPUT OK LED blinks rapidly for a short time, then lights steadily. On a properly functioning DC power supply, the green CB ON LED lights steadily, the blue OUTPUT OK LED blinks for a short time, then lights steadily, and the amber CB OFF LED does not light. 8. Flip the second circuit breaker switch and observe the LEDs on the second power supply faceplate. They should light as described in Step 7. 9. On the management device that was attached in Step 5, observe the trace of the startup sequence to confirm correct startup. If you can issue CLI commands over the connection when the startup is complete, the CIP is installed correctly. If you have connected to a Routing Engine through the port labeled ETHERNET, the flashing of the activity indicator LEDs (either the amber 10 Mbps or the green 100 Mbps LED) indicates that the CIP is connected properly and the Routing Engine is active. M40e and M160 CIP Installation Instructions • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 7 Replace Cables and Wire Connecting to the CIP 8 Figure 6: Install the CIP R 1923 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Replace Cables and Wire Connecting to the CIP Table 1 lists the specifications for the cables that connect to management ports and the wires that connect to the alarm relay contacts. Table 1: Routing Engine Interface Cable and Wire Specifications Cable Type Cable Specification Cable Supplied Maximum Length Router Receptacle Routing Engine console or auxiliary interface RS-232 (EIA-232) serial One 6-ft (1.83-m) length with DB-9/DB-9 connectors 6 ft (1.83 m) DB-9 male Routing Engine Ethernet interface Category 5 cable or equivalent suitable for 100BaseT operation One 15-ft (4.92-m) length with RJ-45/RJ-45 connectors 328 ft (100 m) RJ-45 autosensing Alarm relay contacts 24-AWG to 12-AWG No (0.20 to 3.33 mm2) wire None — M40e and M160 CIP Installation Instructions Replace Cables and Wire Connecting to the CIP To replace the cables that connect external management devices to the CIP, perform the procedures described in the following sections: Replace the Management Ethernet Cable on page 9 Replace the Console or Auxiliary Cable on page 10 Replace Alarm Relay Wire on page 11 Replace the Management Ethernet Cable The cable that plugs into the port labeled ETHERNET on the CIP connects the Routing Engine to a network for out-of-band management. The port accepts a cable with RJ-45/RJ-45 connectors, which is provided with the router as described in Table 1. To replace the cable connecting to a management network, follow this procedure: 1. If a cable is already installed in the ETHERNET port, perform the following steps: a. Depress the tab on the connector (which is shown in Figure 7) and pull the connector straight out of the port. Figure 3 shows the ports that connect to the Routing Engine installed in slot RE0. The arrangement of ports for the Routing Engine in slot RE1 is the same. b. Repeat to disconnect the cable from the network device. 2. Plug one end of the replacement Ethernet cable into the ETHERNET port for the appropriate host module. See Figure 3. 3. Plug the other end of the cable into the network device. 1063 Figure 7: Routing Engine Ethernet Cable Connector M40e and M160 CIP Installation Instructions • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 9 Replace Cables and Wire Connecting to the CIP 10 Replace the Console or Auxiliary Cable The cable that plugs into the port labeled CONSOLE on the CIP connects the Routing Engine to a system console, whereas the cable that plugs into the port labeled AUXILIARY connects the Routing Engine to a laptop, modem, or other auxiliary device. Both ports accept an RS-232 (EIA-232) serial cable with DB-9/DB-9 connectors. One such cable is provided with the router, as detailed in Table 1. If you want to connect a device to both ports, you must supply another cable. To replace the cable connecting to a management console or auxiliary device, follow this procedure: 1. If a cable is already installed in the CONSOLE or AUXILIARY port, perform the following steps: a. Turn off the power to the console or auxiliary device. b. Unscrew the screws securing the cable connector to the port, using a 2.5-mm flat-blade screwdriver if necessary. Figure 8 shows the cable connector. c. Pull the cable connector straight out of the port. d. Disconnect the cable from the console or auxiliary device. 2. Plug the female end of the replacement serial cable into the appropriate CONSOLE or AUXILIARY port. Figure 3 shows the ports that connect to the Routing Engine installed in slot RE0. The arrangement of ports for the Routing Engine in slot RE1 is the same. 3. Tighten the screws on the connector. 4. Power on the auxiliary or console device. Figure 8: Console and Auxiliary Serial Port Connector 1027 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • M40e and M160 CIP Installation Instructions Contact Juniper Networks Replace Alarm Relay Wire The relay contacts on the CIP labeled RED ALARM and YELLOW ALARM connect to external alarm devices that report conditions that trigger a red or yellow alarm (see Figure 4). The terminal blocks that plug into the alarm relay contacts are supplied with the router. They accept wire of any gauge between 24-AWG and 12-AWG (0.20 and 3.33 mm2 ), which is not provided. Use the gauge of wire appropriate for the external device that you are connecting to the terminal block. To replace the wires connecting to an alarm-reporting device, follow this procedure: 1. Prepare the required length of replacement wire with gauge between 24-AWG and 12-AWG (0.20 and 3.33 mm2 ). 2. Select the appropriate relay contact—the upper contact for a device that reports high priority (red) alarms, or the lower contact for the device that reports lower priority (yellow) alarms. 3. Disconnect the existing wire at the external device. 4. Using a 2.5 mm flat-blade screwdriver, loosen the small screws on the face of the terminal block and remove the block from the relay contact. 5. Using a 2.5 mm flat-blade screwdriver, loosen the small screws on the side of the terminal block. Remove existing wires from the slots in the front of the block and insert replacement wires. Tighten the screws to secure the wire. 6. Orient the terminal block according to the labels to the left of the chosen relay contact (NC means “normally closed,” C means “common,” and NO means “normally open”). See Figure 4. 7. Plug the terminal block into the relay contact and use a 2.5 mm flat-blade screwdriver to tighten the screws on the face of the block. 8. Attach the other end of the replacement wire to the external device. Contact Juniper Networks For technical support, contact Juniper Networks at [email protected]. If you are reporting a software problem, please issue the following command from the CLI before contacting support: user@host> request support information | save filename For documentation issues, contact Juniper Networks at [email protected]. To provide a core file to Juniper Networks for analysis, gzip the file, rename the file to include your company name, copy it to ftp.juniper.net:pub/incoming, and then send the filename, along with software version information (the output of the show version command) and the configuration, to [email protected]. M40e and M160 CIP Installation Instructions • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 11 Contact Juniper Networks • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 12 Juniper Networks is a registered trademark of Juniper Networks, Inc. Internet Processor, Internet Processor II, JUNOS, JUNOScript, M5, M10, M20, M40, M40e, and M160 are trademarks of Juniper Networks, Inc. All other trademarks, service marks, registered trademarks, or registered service marks may be the property of their respective owners. All specifications are subject to change without notice. Copyright © 2002, Juniper Networks, Inc. All rights reserved. Printed in USA. M40e and M160 CIP Installation Instructions ">
Download
Advertisement
Key features
Detailed instructions for CIP removal and replacement
Covers Routing Engine interface ports (Ethernet, Console, Auxiliary)
Includes information on alarm relay contacts for external reporting
Specifies required tools for the installation process
Provides guidelines for reconnecting management cables and alarm wires
Supports 10- and 100-Mbps Ethernet connections on Routing Engine ports
Field-replaceable unit (CIP) requires router power down for service
Frequently asked questions
The Connector Interface Panel (CIP) houses interface connectors and alarm relay contacts for the router.
The CIP is located at the left side of the FPC card cage on both M40e and M160 routers.
The CIP provides ETHERNET, CONSOLE, and AUXILIARY ports for connecting Routing Engines to external management devices.
No, the router does not support BITS input, so the BITS A and BITS B ports on the CIP do not function.
The RED ALARM and YELLOW ALARM relay contacts are used for connecting the router to external alarm-reporting devices, activating when corresponding alarm LEDs light on the craft interface.
To replace the CIP, you need Phillips (+) screwdrivers (numbers 1 and 2), an ESD grounding wrist strap, an electrostatic bag or antistatic mat, a 2.5 mm flat-blade (–) screwdriver, and wire cutters if attaching to an external alarm-reporting device.