T4000 Core Router Hardware Guide
Modified: 2018-07-08
Copyright © 2018, Juniper Networks, Inc.
Juniper Networks, Inc.
1133 Innovation Way
Sunnyvale, California 94089
USA
408-745-2000 www.juniper.net
Juniper Networks, the Juniper Networks logo, Juniper, and Junos are registered trademarks of Juniper Networks, Inc. and/or its affiliates in the United States and other countries. All other trademarks may be property of their respective owners.
Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify, transfer, or otherwise revise this publication without notice.
T4000 Core Router Hardware Guide
Copyright © 2018 Juniper Networks, Inc. All rights reserved.
The information in this document is current as of the date on the title page.
YEAR 2000 NOTICE
Juniper Networks hardware and software products are Year 2000 compliant. Junos OS has no known time-related limitations through the year 2038. However, the NTP application is known to have some difficulty in the year 2036.
END USER LICENSE AGREEMENT
The Juniper Networks product that is the subject of this technical documentation consists of (or is intended for use with) Juniper Networks software. Use of such software is subject to the terms and conditions of the End User License Agreement (“EULA”) posted at https://www.juniper.net/support/eula/ . By downloading, installing or using such software, you agree to the terms and conditions of that
EULA.
ii Copyright © 2018, Juniper Networks, Inc.
Table of Contents
Documentation and Release Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxv
Self-Help Online Tools and Resources . . . . . . . . . . . . . . . . . . . . . . . . . xxviii
Errata with the T4000 Router Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
T4000 Connector Interface Panel (CIP) Description . . . . . . . . . . . . . . . . . . . . . . . 14
T4000 Connector Interface Panel (CIP) Components . . . . . . . . . . . . . . . . . . 14
T4000 SONET Clock Generators (SCGs) Description . . . . . . . . . . . . . . . . . . . . . . 20
T4000 SONET Clock Generators (SCGs) LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Cooling System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . 25
Copyright © 2018, Juniper Networks, Inc.
iii
T4000 Core Router Hardware Guide iv
Host Subsystem Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . 29
T4000 RE-C1800 Routing Engine Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
RE-C1800 Routing Engine Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
MX5, MX10, MX40, and MX80 Routing Engine . . . . . . . . . . . . . . . . . . . . . . . . 43
MX2020 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
PTX10008 and PTX10016 Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
TX Matrix Plus (with 3D SIBs) Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . 54
Line Card Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Copyright © 2018, Juniper Networks, Inc.
Table of Contents
Power System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 75
Switch Fabric Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . 79
T4000 Switch Interface Board (SIB) Description . . . . . . . . . . . . . . . . . . . . . . . . . 79
Site Planning, Preparation, and Specifications
Overview of Preparing the Site for the T4000 Router . . . . . . . . . . . . . . . . . . . . . . 87
T4000 Router Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
T4000 Chassis Grounding Cable and Lug Specifications . . . . . . . . . . . . . . . . . . . 90
T4000 Clearance Requirements for Airflow and Hardware Maintenance . . . . . . . 91
Calculating System Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Copyright © 2018, Juniper Networks, Inc.
v
T4000 Core Router Hardware Guide vi
T4000 DC Power System Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . 101
T4000 Power Management (Four 60-A Cables on a Six-Input DC Power
T4000 Power Management (Three 80-A Cables on a Six-Input DC Power
T4000 DC Power Cable and Lugs Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 105
Network Cable and Transceiver Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Understanding Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion . . . 109
Signal Loss in Multimode and Single-Mode Fiber-Optic Cable . . . . . . . . . . 109
Attenuation and Dispersion in Fiber-Optic Cable . . . . . . . . . . . . . . . . . . . . . 109
Calculating Power Budget and Power Margin for Fiber-Optic Cables . . . . . . . . . . 110
Calculating Power Budget for Fiber-Optic Cable . . . . . . . . . . . . . . . . . . . . . . 110
Calculating Power Margin for Fiber-Optic Cable . . . . . . . . . . . . . . . . . . . . . . . 111
Management Cable and Transceiver Specifications and Pinouts . . . . . . . . 113
T4000 Routing Engine Interface Cable Specifications . . . . . . . . . . . . . . . . . . . . . 113
T4000 Alarm Relay Contact Wire Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 114
DB-9 Connector Pinouts for the Routing Engine AUXILIARY and CONSOLE
RJ-45 Connector Pinouts for the T4000 Management ETHERNET Port . . . . . . . 115
Initial Installation and Configuration
Tools and Parts Required to Unpack the T4000 Router . . . . . . . . . . . . . . . . . . . . 123
Installing the T4000 Mounting Hardware for a Four-Post Rack or Cabinet . . . . 129
Installing the T4000 Mounting Hardware for an Open-Frame Rack . . . . . . . . . . 133
Copyright © 2018, Juniper Networks, Inc.
Table of Contents
Removing the Center-Mounting Brackets from the Chassis . . . . . . . . . . . . . 134
Overview of Installing the Router into a Rack . . . . . . . . . . . . . . . . . . . . . . . . . 137
Overview of Installing the T4000 Router into a Rack . . . . . . . . . . . . . . . . . . . . . . 137
Installing the Router into a Rack With a Mechanical Lift . . . . . . . . . . . . . . . 139
Overview of Installing a T4000 Router Using a Mechanical Lift . . . . . . . . . . . . . 139
Tools Required to Install the T4000 Router Using a Mechanical Lift . . . . . . . . . . 139
Installing the T4000 Router Using a Mechanical Lift . . . . . . . . . . . . . . . . . . . . . . 140
Removing the T4000 Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
Attaching the T4000 Installation Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
Installing the T4000 Chassis in a Rack or Cabinet Using a Mechanical
Removing the T4000 Installation Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
Reinstalling the T4000 Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Installing the Router into a Rack Without a Mechanical Lift . . . . . . . . . . . . 147
Overview of Installing a T4000 Router Without a Mechanical Lift . . . . . . . . . . . 147
Tools Required to Install the T4000 Router Without a Mechanical Lift . . . . . . . 148
Removing T4000 Components from the Chassis . . . . . . . . . . . . . . . . . . . . . . . . 148
Removing the T4000 DC Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
Removing the T4000 Control Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
Removing the T4000 Rear Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
Removing the T4000 Front Cable Management System . . . . . . . . . . . . . . . 156
Removing the T4000 Front Fan Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
Installing the T4000 Chassis in a Rack or Cabinet Manually . . . . . . . . . . . . . . . . 160
Reinstalling the T4000 Components in the Chassis . . . . . . . . . . . . . . . . . . . . . . 163
Reinstalling the T4000 Control Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166
Reinstalling the T4000 Front Cable Management System . . . . . . . . . . . . . . 171
Tools and Parts Required to Ground the T4000 Router . . . . . . . . . . . . . . . . . . . . 173
Connecting the Router to External Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
Overview of Connecting the T4000 Router to External Devices . . . . . . . . . . . . . . 177
Tools and Parts Required to Connect the T4000 Router to External Devices . . . 178
Connecting the T4000 Router to a Management Console or Auxiliary Device . . 178
Connecting the T4000 Router to a Management Ethernet Device . . . . . . . . . . . 180
Connecting the T4000 Router to an External Alarm-Reporting Device . . . . . . . . 182
Copyright © 2018, Juniper Networks, Inc.
vii
T4000 Core Router Hardware Guide
Tools and Parts Required to Provide Power to the T4000 Router . . . . . . . . . . . . 185
Connecting DC Power to the T4000 Router (Six 60-A Inputs) . . . . . . . . . . . . . . 186
Connecting DC Power to the T4000 Router (Five 60-A Inputs) . . . . . . . . . . . . . 190
Connecting DC Power to the T4000 Router (Four 60-A Inputs) . . . . . . . . . . . . . 194
Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to
Configuring User Accounts and Passwords . . . . . . . . . . . . . . . . . . . . . . . . . . 210
Configuring DC Power on a T4000 Router (Five 60-A Cables on a Six-Input
Configuring DC Power on a T4000 (Four 60-A Cables on a Six-Input DC
Configuring DC Power on a T4000 (Three 80-A Cables on a Six-Input DC
Upgrading to a T4000 Router From a T640 or T1600 Router . . . . . . . . . . . 217
Overview of Preparing to Upgrade to a T4000 Router . . . . . . . . . . . . . . . . . . . . . 217
Checking the Hardware Version of T640 or T1600 Components . . . . . . . . . . . . 218
Checking the Hardware Version of the Control Boards . . . . . . . . . . . . . . . . . 219
Checking the Hardware Version of the Routing Engines . . . . . . . . . . . . . . . . 221
Checking the Hardware Version of the Rear Fan Tray . . . . . . . . . . . . . . . . . . 223
Checking the Hardware Version of the FPCs . . . . . . . . . . . . . . . . . . . . . . . . . 224
Upgrading Hardware Components on the T640 or T1600 Router . . . . . . . . . . . 228
Preparing to Upgrade the T640 or T1600 Components . . . . . . . . . . . . . . . . 228
Upgrade to the Six-Input DC Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . 229
Removing Unsupported FPCs and PICs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230
Verify That Components Supported by the T4000 Router Are Installed . . . 231
Upgrading to T4000 SIBs with Junos OS Release 12.1 . . . . . . . . . . . . . . . . . . . . . 232
Upgrading to T4000 SIBs Online with Junos OS Release 12.2 and Later . . . . . . . 233
Installing the T4000 FPCs After an Upgrade from a T640 or T1600 Router . . . 235
viii Copyright © 2018, Juniper Networks, Inc.
Table of Contents
Installing and Replacing Components
Overview of Installing and Replacing Components . . . . . . . . . . . . . . . . . . . 239
Tools and Parts Required for Replacing T4000 Hardware Components . . . . . . . 241
Removing the T4000 Craft Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249
Replacing a T4000 Console or Auxiliary Cable . . . . . . . . . . . . . . . . . . . . . . . . . . 250
Removing a T4000 Console or Auxiliary Cable . . . . . . . . . . . . . . . . . . . . . . . 251
Installing a T4000 Console or Auxiliary Cable . . . . . . . . . . . . . . . . . . . . . . . 253
Replacing a T4000 Management Ethernet Cable . . . . . . . . . . . . . . . . . . . . . . . . 253
Removing a T4000 Management Ethernet Cable . . . . . . . . . . . . . . . . . . . . 253
Installing a T4000 Management Ethernet Cable . . . . . . . . . . . . . . . . . . . . . 255
Removing the T4000 Alarm Relay Wires . . . . . . . . . . . . . . . . . . . . . . . . . . . 255
Installing the T4000 Alarm Relay Wires . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
Replacing Cooling System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
Removing the T4000 Lower Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . 265
Installing the T4000 Lower Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . 266
Removing the T4000 Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . 267
Installing the T4000 Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . 269
Removing the T4000 Rear Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270
Replacing Host Subsystem Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273
Replacing T4000 Host Subsystem Components . . . . . . . . . . . . . . . . . . . . . . . . . 273
Taking the T4000 Host Subsystem Offline . . . . . . . . . . . . . . . . . . . . . . . . . . 273
Replacing a Control Board or Routing Engine Component . . . . . . . . . . . . . . 275
Copyright © 2018, Juniper Networks, Inc.
ix
T4000 Core Router Hardware Guide
Removing a T4000 Routing Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282
Replacing a CompactFlash Card in a T4000 RE-C1800 Routing Engine . . . . . . 286
Preparing to Replace a CompactFlash Card in a T4000 RE-C1800 Routing
Removing a CompactFlash Card from a T4000 RE-C1800 Routing
Installing a CompactFlash Card into a T4000 RE-C1800 Routing Engine . . 287
Copying Junos OS to the CompactFlash Card in a T1600 RE-C1800 Routing
Replacing a DIMM Module in a T4000 RE-C1800 Routing Engine . . . . . . . . . . . 289
Removing a DIMM Module from a T4000 RE-C1800 Routing Engine . . . . . 289
Installing a DIMM Module into a T4000 RE-C1800 Routing Engine . . . . . . 289
Replacing a Solid-State Disk in a T4000 RE-C1800 Routing Engine . . . . . . . . . 290
Preparing to Replace a Solid-State Disk from a T4000 RE-C1800 Routing
Removing a Solid-State Disk from a T4000 RE-C1800 Routing Engine . . . 291
Installing a Solid-State Disk From a T4000 RE-C1800 Routing Engine . . . 292
Copying Junos OS to the Solid-State Disk in a T4000 RE-C1800 Routing
Replacing Power System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307
Replacing a T4000 Six-Input DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . 307
Removing a T4000 Six-Input DC Power Supply . . . . . . . . . . . . . . . . . . . . . . 307
Installing a T4000 Six-Input DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . 310
Replacing a T4000 Six-Input DC Power Supply Front Air Filter . . . . . . . . . . . . . . 312
Removing a T4000 Six-Input DC Power Supply Front Air Filter . . . . . . . . . . 313
Installing a T4000 Six-Input DC Power Supply Front Air Filter . . . . . . . . . . . 313
Replacing a T4000 Six-Input DC Power Supply Side Air Filter . . . . . . . . . . . . . . . 313
Removing a T4000 Six-Input DC Power Supply Side Air Filter . . . . . . . . . . . 313
Installing a T4000 Six-Input DC Power Supply Side Air Filter . . . . . . . . . . . . 314
Removing a T4000 DC Power Supply Cable . . . . . . . . . . . . . . . . . . . . . . . . . 315
Installing a T4000 DC Power Supply Cable . . . . . . . . . . . . . . . . . . . . . . . . . . 316
x Copyright © 2018, Juniper Networks, Inc.
Table of Contents
Replacing Switch Fabric Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 319
Removing a T4000 TXP-LCC-3D SIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322
Installing a T4000 TXP-LCC-3D SIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325
Maintaining the Chassis and Components
Routine Maintenance Procedures for the T4000 Router . . . . . . . . . . . . . . . . . . . 331
Tools and Parts Required to Maintain the T4000 Hardware Components . . . . . 333
T4000 Troubleshooting Resources Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 345
Troubleshooting the T4000 Cooling System . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351
Troubleshooting the T4000 Host Subsystems . . . . . . . . . . . . . . . . . . . . . . . . . . 354
Troubleshooting the T4000 Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . 355
Troubleshooting the T4000 Control Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . 356
Troubleshooting the T4000 Power System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363
Copyright © 2018, Juniper Networks, Inc.
xi
T4000 Core Router Hardware Guide xii
Contacting Customer Support and Returning the Chassis or
Locating Component Serial Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377
Displaying T4000 Component Serial Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . 377
T4000 Component Serial Number Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . 379
Power Supply Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383
Routing Engine Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383
Packing and Returning Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 387
Returning a Hardware Component to Juniper Networks, Inc. . . . . . . . . . . . . . . . . 387
Tools and Parts Required to Remove Components from a T4000 Router . . . . . 388
Packing the T4000 Router Components for Shipment . . . . . . . . . . . . . . . . . . . . 389
Safety and Compliance Information
General Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 393
Warning Statement for Norway and Sweden . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397
Installation Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . 401
Rack-Mounting and Cabinet-Mounting Warnings . . . . . . . . . . . . . . . . . . . . . . . . 404
Radiation and Laser Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . 411
Laser and LED Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . 412
Copyright © 2018, Juniper Networks, Inc.
Table of Contents
Maintenance and Operational Safety Warnings . . . . . . . . . . . . . . . . . . . . . . 415
Maintenance and Operational Safety Guidelines and Warnings . . . . . . . . . . . . . 415
Electrical Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . 421
General Electrical Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . 421
Prevention of Electrostatic Discharge Damage . . . . . . . . . . . . . . . . . . . . . . . . . . 423
DC Power Grounding Requirements and Warning . . . . . . . . . . . . . . . . . . . . . . . . 427
Multiple Power Supplies Disconnection Warning . . . . . . . . . . . . . . . . . . . . . . . . . 432
Agency Approvals and Compliance Statements . . . . . . . . . . . . . . . . . . . . . 435
Compliance Statements for EMC Requirements . . . . . . . . . . . . . . . . . . . . . . . . . 436
Compliance Statements for Environmental Requirements . . . . . . . . . . . . . . . . . 437
T4000 Compliance Statements for NEBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 437
T4000 Compliance Statements for Acoustic Noise . . . . . . . . . . . . . . . . . . . . . . 438
Copyright © 2018, Juniper Networks, Inc.
xiii
T4000 Core Router Hardware Guide xiv Copyright © 2018, Juniper Networks, Inc.
List of Figures
Cooling System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . 25
Host Subsystem Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . 29
Line Card Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Power System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 75
Switch Fabric Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . 79
Site Planning, Preparation, and Specifications
Copyright © 2018, Juniper Networks, Inc.
xv
T4000 Core Router Hardware Guide xvi
Figure 27: Chassis Dimensions and Clearance Requirements . . . . . . . . . . . . . . . . . 91
Figure 29: Typical DC Source Cabling to the Router . . . . . . . . . . . . . . . . . . . . . . . 105
Initial Installation and Configuration
Figure 32: Installing the Mounting Hardware for a Four-Post Rack or Cabinet . . . 131
Figure 34: Installing the Mounting Hardware for an Open-Frame Rack . . . . . . . . 134
Figure 35: Removing the Center-Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . . 135
Installing the Router into a Rack With a Mechanical Lift . . . . . . . . . . . . . . . 139
Installing the Router into a Rack Without a Mechanical Lift . . . . . . . . . . . . 147
Figure 41: Components to Remove from the Rear of the T4000 Router . . . . . . . 149
Figure 42: Components to Remove from the Front of the T4000 Router . . . . . . 150
Figure 43: Removing a Six-Input DC Power Supply Before Installing the
Figure 57: Reinstalling a Six-Input DC Power Supply . . . . . . . . . . . . . . . . . . . . . . 169
Copyright © 2018, Juniper Networks, Inc.
List of Figures
Connecting the Router to External Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
Figure 63: Console and Auxiliary Serial Port Connector . . . . . . . . . . . . . . . . . . . . 179
Figure 65: Routing Engine Ethernet Cable Connector . . . . . . . . . . . . . . . . . . . . . . 181
Figure 69: Connecting Negative (–) DC Power Cables to INPUT 0, INPUT 1,
Figure 70: Connecting Negative (–) DC Power Cables to INPUT 2 and
Figure 71: Connecting Positive (+) DC Power Cables to RTN 2, RTN 5, RTN 0,
Figure 73: Connecting Negative (–) DC Power Cables to INPUT 0, INPUT 1,
Figure 74: Connecting Negative (–) DC Power Cable to INPUT 2 . . . . . . . . . . . . . 193
Figure 75: Connecting Positive (+) DC Power Cable to RTN 2, RTN 0, RTN 1,
Figure 77: Connecting Negative (–) DC Power Cables to INPUT 0, INPUT 1. INPUT
Figure 82: Negative (–) DC Power Cables Connected to INPUT 1 and INPUT 3 . . 202
Figure 83: Connecting Negative (–) DC Power Cable to INPUT 5 . . . . . . . . . . . . 203
Figure 84: Positive (+) DC Power Cables Connected to RTN 1, RTN 3, and RTN
Installing and Replacing Components
Copyright © 2018, Juniper Networks, Inc.
xvii
T4000 Core Router Hardware Guide xviii
Replacing Cooling System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
Figure 102: Removing the T4000 Lower Front Fan Tray . . . . . . . . . . . . . . . . . . . 266
Figure 103: Installing the T4000 Lower Front Fan Tray . . . . . . . . . . . . . . . . . . . . 267
Figure 104: Removing an Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . 268
Figure 106: Removing the FAN-R-TXP-3D-LCC Rear Fan Tray . . . . . . . . . . . . . . . 271
Replacing Host Subsystem Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273
Figure 111: Removing a T4000 C1800 Routing Engine . . . . . . . . . . . . . . . . . . . . . 283
Replacing Power System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307
Figure 123: Disconnecting Power Cables from the DC Power Supply . . . . . . . . . 308
Figure 125: Rear of the Power Supply Showing Midplane Connectors . . . . . . . . . 310
Figure 126: Inserting the DC Power Supply into the Chassis . . . . . . . . . . . . . . . . . 310
Figure 128: Removing the Power Supply Side Air Filter . . . . . . . . . . . . . . . . . . . . . 314
Replacing Switch Fabric Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 319
Copyright © 2018, Juniper Networks, Inc.
List of Figures
Figure 139: Connecting a CXP Cable to a CXP Transceiver . . . . . . . . . . . . . . . . . . 327
Maintaining the Chassis and Components
Contacting Customer Support and Returning the Chassis or
Locating Component Serial Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377
Figure 146: Serial Number Label on a T1600 Type 4 FPC . . . . . . . . . . . . . . . . . . . 381
Figure 149: DC Power Supply Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . 383
Safety and Compliance Information
Electrical Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . 421
Figure 153: Placing a Component into an Antistatic Bag . . . . . . . . . . . . . . . . . . . 424
Copyright © 2018, Juniper Networks, Inc.
xix
T4000 Core Router Hardware Guide xx Copyright © 2018, Juniper Networks, Inc.
List of Tables
Cooling System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . 25
Host Subsystem Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . 29
Table 12: End-of-Life Routing Engine Specifications . . . . . . . . . . . . . . . . . . . . . . . 39
Table 18: MX5, MX10, MX40, and MX80 Routing Engine . . . . . . . . . . . . . . . . . . . . 44
Table 20: MX240 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Table 22: MX960 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Table 23: MX2008 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Table 24: MX2010 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Table 25: MX2020 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Table 26: MX10003 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Table 30: PTX10008 and PTX10016 Routing Engines . . . . . . . . . . . . . . . . . . . . . . 51
Copyright © 2018, Juniper Networks, Inc.
xxi
T4000 Core Router Hardware Guide xxii
Table 37: Routing Engines on TX Matrix Plus with 3D SIBs . . . . . . . . . . . . . . . . . . . 55
Line Card Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Table 38: Identifying the FPCs Supported by the Router . . . . . . . . . . . . . . . . . . . . 58
Table 39: FPCs Supported by the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Table 40: Number of PICs Supported in Each FPC . . . . . . . . . . . . . . . . . . . . . . . . . 62
Table 41: ATM IQ PICs Supported in the T4000 Router . . . . . . . . . . . . . . . . . . . . . 63
Table 42: Channelized PICs Supported in the T4000 Router . . . . . . . . . . . . . . . . 64
Table 43: Gigabit Ethernet PICs Supported in the T4000 Router . . . . . . . . . . . . . 64
Table 44: 10-Gigabit Ethernet PICs Supported in the T4000 Router . . . . . . . . . . 65
Table 45: 40-Gigabit Ethernet PICs Supported in the T4000 Router . . . . . . . . . . 65
Table 46: 100-Gigabit Ethernet PICs Supported in the T4000 Router . . . . . . . . . 66
Table 47: Services PICs Supported in the T4000 Router . . . . . . . . . . . . . . . . . . . . 66
Table 48: SONET/SDH PICs Supported in the T4000 Router . . . . . . . . . . . . . . . . 66
Table 49: End-of-Life PICs Supported in the T4000 Router . . . . . . . . . . . . . . . . . 67
Table 50: T4000 PIC/FPC Compatibility Type 1 . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Power System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 75
Table 56: Components Powered by Each Six-Input DC Power Supply Input . . . . 76
Switch Fabric Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . 79
Table 59: T4000 and TXP-LCC-3D SIB LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Site Planning, Preparation, and Specifications
Calculating System Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Table 65: Typical DC Power Requirements for T4000 Components . . . . . . . . . . . 97
Table 66: DC Power System Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . 101
Copyright © 2018, Juniper Networks, Inc.
List of Tables
Network Cable and Transceiver Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Table 69: Estimated Values for Factors Causing Link Loss . . . . . . . . . . . . . . . . . . . 111
Management Cable and Transceiver Specifications and Pinouts . . . . . . . . 113
Table 70: Cable Specifications for Routing Engine Management . . . . . . . . . . . . . 113
Initial Installation and Configuration
Table 75: Four-Post or Cabinet Rack Mounting Hole Locations . . . . . . . . . . . . . . 129
Table 76: Open-Frame Rack Mounting Hole Locations . . . . . . . . . . . . . . . . . . . . . 133
Installing and Replacing Components
Overview of Installing and Replacing Components . . . . . . . . . . . . . . . . . . . 239
Table 78: Tools and Parts Required for Component Replacement . . . . . . . . . . . . 241
Replacing Host Subsystem Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273
Table 79: Effect of Taking the Host Subsystem Offline . . . . . . . . . . . . . . . . . . . . 274
Table 80: SONET/SDH Interface Alarm Messages . . . . . . . . . . . . . . . . . . . . . . . 348
Table 81: Chassis Alarm Messages for the Craft Interface . . . . . . . . . . . . . . . . . . 349
Table 82: Chassis Alarm Messages for the SCGs . . . . . . . . . . . . . . . . . . . . . . . . . 350
Table 83: T4000 Cooling System Fan Tray Alarms . . . . . . . . . . . . . . . . . . . . . . . . 351
Table 85: Chassis Alarm Messages for Host Subsystems . . . . . . . . . . . . . . . . . . 354
Table 86: T4000 Chassis Alarm Messages and Solutions for the Control
Table 87: Chassis Alarm Messages for the FPCs . . . . . . . . . . . . . . . . . . . . . . . . . 358
Table 90: T4000 Chassis Alarm Messages for SIBs . . . . . . . . . . . . . . . . . . . . . . 368
Copyright © 2018, Juniper Networks, Inc.
xxiii
T4000 Core Router Hardware Guide xxiv Copyright © 2018, Juniper Networks, Inc.
About the Documentation
•
Documentation and Release Notes on page xxv
•
Documentation Conventions on page xxv
•
Documentation Feedback on page xxvii
•
Requesting Technical Support on page xxviii
Documentation and Release Notes
To obtain the most current version of all Juniper Networks
® technical documentation, see the product documentation page on the Juniper Networks website at https://www.juniper.net/documentation/ .
If the information in the latest release notes differs from the information in the documentation, follow the product Release Notes.
Juniper Networks Books publishes books by Juniper Networks engineers and subject matter experts. These books go beyond the technical documentation to explore the nuances of network architecture, deployment, and administration. The current list can be viewed at https://www.juniper.net/books .
Documentation Conventions
defines notice icons used in this guide.
Copyright © 2018, Juniper Networks, Inc.
xxv
T4000 Core Router Hardware Guide
Table 1: Notice Icons
Icon Meaning
Informational note
Caution
Warning
Laser warning
Tip
Best practice
Description
Indicates important features or instructions.
Indicates a situation that might result in loss of data or hardware damage.
Alerts you to the risk of personal injury or death.
Alerts you to the risk of personal injury from a laser.
Indicates helpful information.
Alerts you to a recommended use or implementation.
defines the text and syntax conventions used in this guide.
Table 2: Text and Syntax Conventions
Convention Description Examples
Bold text like this
Fixed-width text like this
Represents text that you type.
Represents output that appears on the terminal screen.
To enter configuration mode, type the configure command: user@host> configure user@host> show chassis alarms
No alarms currently active
Italic text like this
Italic text like this
•
•
•
Introduces or emphasizes important new terms.
Identifies guide names.
Identifies RFC and Internet draft titles.
•
•
•
A policy term is a named structure that defines match conditions and actions.
Junos OS CLI User Guide
RFC 1997, BGP Communities Attribute
Represents variables (options for which you substitute a value) in commands or configuration statements.
Configure the machine’s domain name:
[edit] root@# set system domain-name domain-name xxvi Copyright © 2018, Juniper Networks, Inc.
About the Documentation
Table 2: Text and Syntax Conventions (continued)
Convention Description
Text like this
< > (angle brackets)
| (pipe symbol)
Examples
Represents names of configuration statements, commands, files, and directories; configuration hierarchy levels; or labels on routing platform components.
•
•
To configure a stub area, include the stub statement at the [edit protocols ospf area area-id] hierarchy level.
The console port is labeled CONSOLE .
Encloses optional keywords or variables.
stub <default-metric metric >;
Indicates a choice between the mutually exclusive keywords or variables on either side of the symbol. The set of choices is often enclosed in parentheses for clarity.
broadcast | multicast
( string1 | string2 | string3 )
# (pound sign)
[ ] (square brackets)
Indention and braces ( { } )
; (semicolon)
Indicates a comment specified on the same line as the configuration statement to which it applies.
rsvp { # Required for dynamic MPLS only
Encloses a variable for which you can substitute one or more values.
Identifies a level in the configuration hierarchy.
Identifies a leaf statement at a configuration hierarchy level.
community name members [ community-ids ]
[edit] routing-options { static { route default { nexthop address; retain;
}
}
}
GUI Conventions
Bold text like this
> (bold right angle bracket)
Represents graphical user interface (GUI) items you click or select.
•
•
In the Logical Interfaces box, select
All Interfaces .
To cancel the configuration, click
Cancel .
Separates levels in a hierarchy of menu selections.
In the configuration editor hierarchy, select Protocols>Ospf .
Documentation Feedback
We encourage you to provide feedback, comments, and suggestions so that we can improve the documentation. You can provide feedback by using either of the following methods:
• Online feedback rating system—On any page of the Juniper Networks TechLibrary site at https://www.juniper.net/documentation/index.html
, simply click the stars to rate the content, and use the pop-up form to provide us with information about your experience.
Alternately, you can use the online feedback form at https://www.juniper.net/documentation/feedback/ .
Copyright © 2018, Juniper Networks, Inc.
xxvii
T4000 Core Router Hardware Guide
• E-mail—Send your comments to [email protected]
. Include the document or topic name, URL or page number, and software version (if applicable).
Requesting Technical Support
Technical product support is available through the Juniper Networks Technical Assistance
Center (JTAC). If you are a customer with an active J-Care or Partner Support Service support contract, or are covered under warranty, and need post-sales technical support, you can access our tools and resources online or open a case with JTAC.
• JTAC policies—For a complete understanding of our JTAC procedures and policies, review the JTAC User Guide located at https://www.juniper.net/us/en/local/pdf/resource-guides/7100059-en.pdf
.
• Product warranties—For product warranty information, visit https://www.juniper.net/support/warranty/ .
• JTAC hours of operation—The JTAC centers have resources available 24 hours a day,
7 days a week, 365 days a year.
Self-Help Online Tools and Resources
For quick and easy problem resolution, Juniper Networks has designed an online self-service portal called the Customer Support Center (CSC) that provides you with the following features:
• Find CSC offerings: https://www.juniper.net/customers/support/
• Search for known bugs: https://prsearch.juniper.net/
• Find product documentation: https://www.juniper.net/documentation/
• Find solutions and answer questions using our Knowledge Base: https://kb.juniper.net/
• Download the latest versions of software and review release notes: https://www.juniper.net/customers/csc/software/
• Search technical bulletins for relevant hardware and software notifications: https://kb.juniper.net/InfoCenter/
• Join and participate in the Juniper Networks Community Forum: https://www.juniper.net/company/communities/
• Open a case online in the CSC Case Management tool: https://www.juniper.net/cm/
To verify service entitlement by product serial number, use our Serial Number Entitlement
(SNE) Tool: https://entitlementsearch.juniper.net/entitlementsearch/
Opening a Case with JTAC
You can open a case with JTAC on the Web or by telephone.
• Use the Case Management tool in the CSC at https://www.juniper.net/cm/ .
• Call 1-888-314-JTAC (1-888-314-5822 toll-free in the USA, Canada, and Mexico).
xxviii Copyright © 2018, Juniper Networks, Inc.
About the Documentation
For international or direct-dial options in countries without toll-free numbers, see https://www.juniper.net/support/requesting-support.html
.
Copyright © 2018, Juniper Networks, Inc.
xxix
T4000 Core Router Hardware Guide xxx Copyright © 2018, Juniper Networks, Inc.
PART 1
Overview
•
•
T4000 Router Release Notes on page 9
•
Chassis Components and Description on page 11
•
Cooling System Components and Descriptions on page 25
•
Host Subsystem Components and Descriptions on page 29
•
Line Card Components and Descriptions on page 57
•
Power System Components and Descriptions on page 75
•
Switch Fabric Components and Descriptions on page 79
Copyright © 2018, Juniper Networks, Inc.
1
T4000 Core Router Hardware Guide
2 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 1
System Overview
•
T4000 Router Description on page 3
•
T4000 Hardware Component Overview on page 5
•
T4000 Component Redundancy on page 7
T4000 Router Description
The Juniper Networks T4000 Core Router is a complete routing system that provides
Gigabit Ethernet, SONET/SDH, and other high-speed interfaces for large networks and network applications, such as those supported by Internet service providers (ISPs). The
T4000 router accommodates up to eight Flexible PIC Concentrators (FPCs), each of which can be configured with a variety of network media types. The router provides up to 2.0 terabits per second (Tbps), full duplex (4.0 Tbps of any-to-any, nonblocking, half-duplex) switching.
The router architecture cleanly separates control operations from packet forwarding operations. This design eliminates processing and traffic bottlenecks, permitting the router to achieve high performance.
• Control operations in the router are performed by the host subsystem, which runs the
Junos operating system (Junos OS) to handle routing protocols, traffic engineering, policy, policing, monitoring, and configuration management.
• Forwarding operations in the router are performed by the Packet Forwarding Engines, which consist of hardware, including ASICs, designed by Juniper Networks.
Application-specific integrated circuits (ASICs) are a definitive part of the router design; they enable the router to achieve data forwarding rates that match current fiber-optic capacity. The T4000 router provides up to a total of 2.4 billion packets per second
(Mpps) of forwarding.
and
illustrate the front and rear of a T4000 router.
Copyright © 2018, Juniper Networks, Inc.
3
T4000 Core Router Hardware Guide
Figure 1: Front View of the T4000 Router
Front-mounting flange
Center-mounting bracket
Craft interface
Fan tray
FPCs
CIP
T Series
FANTRAY-T4000
ESD point
Air filter
Fan tray
Air intake
FANTRA
Y-T4000
4 Copyright © 2018, Juniper Networks, Inc.
Chapter 1: System Overview
Figure 2: Rear View of the T4000 Router
Fan tray
Air exhaust
SCGs
Control board 0
RE 0
RE 1
Control board 1
SIBs
Air filter
Power supply 0
Power supply 1
ESD point
Grounding points
Related
Documentation
•
T4000 Chassis Description on page 11
•
Overview of Installing the T4000 Router on page 119
T4000 Hardware Component Overview
The T4000 Core Router supports the components in
alphabetic order.
Table 3: T4000 Hardware Components
Component Hardware Model Number CLI Name Description
Cable management system N/A N/A
Copyright © 2018, Juniper Networks, Inc.
5
T4000 Core Router Hardware Guide
Table 3: T4000 Hardware Components (continued)
Component Hardware Model Number CLI Name
Chassis N/A N/A
Description
“T4000 Chassis Description” on page 11
Cooling system, including fan trays and air filters
Front fan trays FANTRAY-T4000
Rear fan tray
Air filter kit
Control board
Craft interface
FPC
Host subsystem
Midplane
PIC
Power system
Routing Engine
8G C1800 Routing Engine
16G C1800 Routing Engine
FAN-REAR-TXP-LCC
FAN-R-TXP-3D-LCC
FLTR-KIT-T640
CB-LCC
CRAFT-T-SERIES
Front Top Fan Tray
Front Bottom Fan Tray
Rear Fan Tray
N/A
LCC Control Board
T4000 FPM Display
See
“T4000 FPCs Supported” on page 61
See control board and Routing Engine.
“T4000 FPC Description” on page 57
N/A
PWR-T-6-60-DC
T-series Backplane
See the T4000 Core Router
Interface Module Reference .
See show chassis hardware
“T4000 PIC Description” on page 62
Power Entry Module 6x60
“T4000 Midplane Description” on page 18
“T4000 Power System Description” on page 75
RE-DUO-C1800-8G
RE-DUO-C1800-16G
SONET Clock Generator (SCG)
SCG with RJ-48 ports SCG-T-EC
SCG with DB-9 ports SCG-T
RE-DUO-1800
RE-DUO-1800-16G
T640 Sonet Clock Gen.
T640 Sonet Clock Gen.
“T4000 Control Board Description” on page 30
“T4000 Craft Interface Description” on page 16
“T4000 RE-C1800 Routing Engine
(SCGs) Description” on page 20
6 Copyright © 2018, Juniper Networks, Inc.
Chapter 1: System Overview
Table 3: T4000 Hardware Components (continued)
Component Hardware Model Number CLI Name
Switch Interface Board
(SIB)
SIB-I-T4000
SIB-TXP-3D-LCC
SIB-HC-3D
Description
Related
Documentation
•
T4000 Router Description on page 3
•
T4000 Component Redundancy on page 7
T4000 Component Redundancy
The T4000 Core Router is designed so that no single point of failure can cause the entire system to fail. The following major hardware components are redundant:
• Switch Interface Boards (SIBs)—The router has five SIBs. For more information, see
“T4000 Switch Interface Board (SIB) Description” on page 79
.
• Host subsystem—The host subsystem consists of a Routing Engine functioning together with a control board. The router can have one or two host subsystems. If two host subsystems are installed, one functions as the master and the other functions as the backup. If the master host subsystem (or either of its components) fails, the backup can take over as the master. To operate, each host subsystem requires a Routing Engine installed in an adjacent slot to a control board. For more information, see
RE-C1800 Routing Engine Description” on page 34
,
, and
“T4000 Host Subsystem Description” on page 29 .
If the Routing Engines are configured for nonstop active routing, the backup Routing
Engine automatically synchronizes its configuration and state with the master Routing
Engine. Any update to the master Routing Engine state is replicated on the backup
Routing Engine. If the backup Routing Engine assumes mastership, packet forwarding continues through the router without interruption. For more information about nonstop active routing, see the Junos OS High Availability Library for Routing Devices .
• SONET Clock Generators (SCGs)—The router has a standard configuration of one
SCG. A second can be purchased to function as backup. If one SCG fails, the other becomes the master SCG. Mastership of the SCGs is independent of the host subsystem, so routing functions are not affected. For more information, see
Generators (SCGs) Description” on page 20
.
• Power supplies—The router has two power supplies, which share the load evenly. If one power supply fails, the other power supply can provide full power to the router indefinitely. For more information, see
“T4000 Power System Description” on page 75 .
• Cooling system—The cooling system has redundant components, which are controlled by the host subsystem. If one of the fans fails, the host subsystem increases the speed of the remaining fans to provide sufficient cooling for the router indefinitely. For more information, see
“T4000 Cooling System Description” on page 25 .
Copyright © 2018, Juniper Networks, Inc.
7
T4000 Core Router Hardware Guide
Related
Documentation
•
T4000 Router Description on page 3
8 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 2
T4000 Router Release Notes
•
Outstanding Issues with the T4000 Router on page 9
•
Errata with the T4000 Router Documentation on page 9
Outstanding Issues with the T4000 Router
This topic lists outstanding hardware issues with the T4000 Core Router.
• To support the 10-Gigabit Ethernet LAN/WAN PIC with Oversubscription and SFP+
(model number PD-5-10XGE-SFPP) in the T1600-FPC4-ES (part number 710-013037),
REV 13 and later is required.
T1600-FPC4-ES (part number 710-013037), REV 12 and earlier does not support the
10-Gigabit Ethernet LAN/WAN PIC with Oversubscription and SFP+ (model number
PD-5-10XGE-SFPP).
For information about software issues, see the Junos OS Release Notes .
Related
Documentation
•
Errata with the T4000 Router Documentation on page 9
Errata with the T4000 Router Documentation
The name of the T1600 Core Router PIC Guide has changed to T1600 Core Router Interface
Module Reference . Some documentation references still refer to the T1600 Core Router
PIC Guide .
Related
Documentation
•
Outstanding Issues with the T4000 Router on page 9
Copyright © 2018, Juniper Networks, Inc.
9
T4000 Core Router Hardware Guide
10 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 3
Chassis Components and Description
•
T4000 Chassis Description on page 11
•
T4000 Cable Management System on page 13
•
T4000 Connector Interface Panel (CIP) Description on page 14
•
T4000 Craft Interface Description on page 16
•
T4000 Midplane Description on page 18
•
T4000 SONET Clock Generators (SCGs) Description on page 20
•
T4000 SONET Clock Generators (SCGs) LEDs on page 22
T4000 Chassis Description
The T4000 Core Router chassis is a rigid sheet metal structure that houses all the other router components (see
and
Figure 4 on page 13 ). The chassis
measures 37.45 in. (95.1 cm) high, 31 in. (78.7 cm) deep, and 17.43 in. (44.3 cm) wide. The chassis can be installed into many types of racks or cabinets.
The chassis includes the following features (see
and
• Front-mounting flanges for mounting in a four-post rack or cabinet or front-mounting in an open-frame rack.
• Center-mounting metal brackets for center-mounting in an open-frame rack.
• Handles on each side to facilitate positioning the router in the rack. Do not use the handles to lift the router.
• Two electrostatic discharge (ESD) points (banana plug receptacles), one front and one rear.
CAUTION: Before removing or installing components of a router, attach an ESD strap to an ESD point, and place the other end of the strap around your bare wrist. Failure to use an ESD strap could result in damage to the router.
Copyright © 2018, Juniper Networks, Inc.
11
T4000 Core Router Hardware Guide
WARNING: The router must be connected to earth ground during normal operation.
Figure 3: Front View of Router Chassis
Front-mounting flange
Center-mounting bracket
Craft interface
Fan tray
FPCs
CIP
T Series
FANTRAY-T4000
ESD point
Air filter
Fan tray
Air intake
FANTRA
Y-T4000
12 Copyright © 2018, Juniper Networks, Inc.
Chapter 3: Chassis Components and Description
Figure 4: Rear View of Router Chassis
Fan tray
Air exhaust
SCGs
Control board 0
RE 0
RE 1
Control board 1
SIBs
Air filter
Power supply 0
Power supply 1
ESD point
Grounding points
Related
Documentation
•
T4000 Router Description on page 3
•
T4000 Router Physical Specifications on page 91
•
T4000 Component Serial Number Locations on page 379
T4000 Cable Management System
The front cable management system (see
) consists of a row of nine semicircular plastic bobbins mounted on the front of the router below the FPC card cage.
The PIC cables pass between the bobbins and into the tray, keeping the cables organized and securely in place. The curvature of the bobbins also helps maintain the proper bend radius for optical PIC cables.
Copyright © 2018, Juniper Networks, Inc.
13
T4000 Core Router Hardware Guide
You can pull the front cable management system up and outward to lock it into the maintenance position. This allows you to access the lower fan tray and the front air filter.
Figure 5: Front Cable Management System
For T4000 routers connected to a TX Matrix Plus router, you can use the optional rear cable management system (model number CBL-MGR-TXP-3D-LCC) to organize, support, and provide strain relief for the cables connected to the TXP-LCC-3D SIBs and the cables connected to the LCC-CBs. The rear cable management system consists of one cable management arm. The cables are routed to the left side of the T4000 router, and then toward the top of the chassis, where you can route the cables to the TX Matrix Plus router.
The cable management system adds 9.5 in. (24.1 cm) to the depth of the T4000 chassis, and 2.4 in. (6.2 cm) to the left side of the chassis.
The LCC rear cable management system can be used for any configuration including,
TXP-T1600 configuration, TXP-T1600-3D configuration, TXP-T4000-3D configuration, and TXP-Mixed-LCC-3D configuration.
See the TX Matrix Plus Router Hardware Guide for instructions on installing and using the
T4000 rear cable management system.
Related
Documentation
•
T4000 Chassis Description on page 11
•
T4000 FPC Description on page 57
•
T4000 PIC Description on page 62
T4000 Connector Interface Panel (CIP) Description
•
T4000 Connector Interface Panel (CIP) Components on page 14
•
•
T4000 Alarm Relay Contacts on page 16
T4000 Connector Interface Panel (CIP) Components
The Connector Interface Panel (CIP) consists of Ethernet, console, and auxiliary ports for the Routing Engines and alarm relay contacts (see
Figure 6 on page 15 ). The CIP is
14 Copyright © 2018, Juniper Networks, Inc.
Chapter 3: Chassis Components and Description located at the left side of the FPC card cage, above the front electrostatic discharge point.
The CIP is hot-pluggable.
Figure 6: CIP
HOST
0
ETHERNET
ACT 0
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
HOST
1
ETHERNET
ACT 1
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
RED ALARM
NC
C
NO
NC
C
NO
YELLOW
ALARM
Management Ports
The CIP has two sets of management ports (see
Figure 6 on page 15 ) that you use to
connect the Routing Engines to external management devices. The upper set of ports, labeled HOST 0 , connects to the Routing Engine in slot RE0 ; and the lower set, labeled
Copyright © 2018, Juniper Networks, Inc.
15
T4000 Core Router Hardware Guide
HOST 1 , connects to the Routing Engine in slot RE1 . From these management devices, you can use the CLI to configure the router.
Each set includes the following ports:
• ETHERNET —Connects the Routing Engine through an Ethernet connection to a management LAN (or any other device that plugs into an Ethernet connection) for out-of-band management. The port uses an autosensing RJ-45 connector to support both 10- and 100-Mbps connections. Two small LEDs on the left edge of the port indicate the connection in use: the yellow LED lights for a 10-Mbps connection, and the green LED lights for a 100-Mbps connection.
• CONSOLE —Connects the Routing Engine to a system console through an RS-232
(EIA-232) serial cable.
• AUXILIARY — Connects the Routing Engine to a laptop, modem, or other auxiliary device through an RS-232 (EIA-232) serial cable.
T4000 Alarm Relay Contacts
The CIP has two alarm relay contacts for connecting the router to external alarm devices
(see
). Whenever a system condition triggers either the red or yellow alarm on the craft interface, the alarm relay contacts are also activated. The alarm relay contacts are located below the Routing Engine ports. The terminal blocks that plug into the alarm relay contacts are supplied with the router. They accept wire of any gauge between 28-AWG and 14-AWG (0.08 and 2.08 mm
2
), which is not provided. Use the gauge of wire appropriate for the external device you are connecting.
Related
Documentation
•
Overview of Connecting the T4000 Router to External Devices on page 177
•
Tools and Parts Required to Connect the T4000 Router to External Devices on page 178
•
Connecting the T4000 Router to a Management Console or Auxiliary Device on page 178
•
Connecting the T4000 Router to an External Alarm-Reporting Device on page 182
•
Connecting the T4000 Router to a Management Ethernet Device on page 180
T4000 Craft Interface Description
The craft interface allows you to view status and troubleshooting information at a glance and to perform many system control functions. It is hot-insertable and hot-removable.
The craft interface is located on the front of the T4000 Core Router above the FPCs (see
).
16 Copyright © 2018, Juniper Networks, Inc.
Chapter 3: Chassis Components and Description
Figure 7: Front Panel of the Craft Interface
Red alarm
LED
Yellow alarm
LED
LCD display
Host subsystem
LEDs
SIB
LEDs
FAIL
FPC 0
OK
ACO/LT
FAIL
FPC 1
OK
MENU
ENTER
FAIL
FPC 2
OK FAIL
FPC 3
OK FAIL
FPC 4
OK FAIL
FPC 5
OK
FAIL
FAIL
OK MASTER
HOST0
OK MASTER
HOST1
FAIL
FPC 6
OK
SP0
SP1
SP2
SP3
SP4
FAIL OK
FAIL
FPC 7
OK
FPC LEDs and online/offline buttons
•
Craft Interface Front Panel on page 17
•
Craft Interface LCD on page 17
Craft Interface Front Panel
The front panel of the craft interface contains:
• A four-line LCD display, along with six navigation buttons. The LCD display operates in Idle mode or alarm mode.
• ONLINE/OFFLINE button for each FPC that you use to take the FPC offline and bring it online. The button is located next to the FPC LEDs on the bottom of the craft interface.
• LEDs
• Yellow Minor Alarm LED, Red Major Critical Alarm LED, and alarm cutoff/lamp test
ACO/LT button
• Host subsystem Master , OK , and FAIL LEDs
• SIB OK and FAIL LEDs
• FPC OK and FAIL LEDs for the fans
Craft Interface LCD
A four-line LCD is located in the craft interface, along with six navigation buttons. The
LCD operates in two modes:
• LED idle mode
• LED alarm mode
During normal operation, the LCD operates in idle mode and reports current status information, as shown in
.
Copyright © 2018, Juniper Networks, Inc.
17
T4000 Core Router Hardware Guide
Figure 8: LCD in Idle Mode
The lines in the display report the following information:
• First line—Router name.
• Second line—Length of time the router has been running, reported in the following form:
Up days + hours:minutes
• Third and fourth lines—Status messages, which rotate at 2-second intervals. Some conditions, such as removal or insertion of a system component, can interrupt the messages.
To add a message that alternates every 2 seconds with the default status messages, use the set chassis display message command.
When a red or yellow alarm occurs, the LCD switches to alarm mode and reports the alarm condition, as shown in
Figure 9: LCD in Alarm Mode
The lines in the display report the following information:
• First line—Router name.
• Second line—Number of active alarms.
• Third and fourth lines—Individual alarm messages, with the most severe condition shown first. The prefix on each line indicates whether the alarm is a red ( R ) or yellow ( Y ) alarm.
Related
Documentation
• T4000 Craft Interface LEDs
•
T4000 Alarm Messages Overview on page 347
T4000 Midplane Description
The midplane is located in the center of the chassis and forms the rear of the FPC card cage (see
Figure 10 on page 19 ). The FPCs install into the midplane from the front of the
18 Copyright © 2018, Juniper Networks, Inc.
Chapter 3: Chassis Components and Description chassis, and the SIBs, Routing Engines, and control boards and SCGs install into the midplane from the rear of the chassis. The power supplies and cooling system components also connect to the midplane.
The midplane performs the following major functions:
• Data path—Data packets are transferred across the midplane from the Packet
Forwarding Engine on the originating FPC to the SIBs, and from the SIBs across the midplane to the Packet Forwarding Engine on the destination FPC.
• Power distribution—The router power supplies are connected to the midplane, which distributes power to all the router components.
• Signal path—The midplane provides the signal path to the FPCs, SIBs, Routing Engines,
CB, and other system components for monitoring and control of the system.
Figure 10: Midplane
Midplane
FPC card cage
Copyright © 2018, Juniper Networks, Inc.
19
T4000 Core Router Hardware Guide
Related
Documentation
•
T4000 Router Description on page 3
•
T4000 Chassis Description on page 11
•
T4000 Component Redundancy on page 7
T4000 SONET Clock Generators (SCGs) Description
•
•
•
•
•
SCG Slots
The SCGs are installed into the upper rear of the chassis in the slots labeled SCG0 and
SCG1 .
SCG Function
SCGs provide 19.44-MHz Stratum 3 clock signal for the SONET/SDH interfaces on the router.
SCG Redundancy
One SCG is shipped as part of the standard router configuration, but up to two SCGs can be installed to provide redundancy. A nonredundant SCG is hot-pluggable. For redundant
SCGs, the master SCG is hot-pluggable. If the master SCG is functioning, the backup
SCG is hot-removable and hot-insertable. Removing the backup SCG does not affect the functioning of the router. Taking the master SCG offline might result in a brief loss of
SONET clock lock while the backup SCG becomes the master.
Supported SCGs
The T4000 router supports the SCG in
.
NOTE: Redundant SCGs must be the same model number, except during upgrade.
Table 4: Supported SCG
Name
SCG with RJ-48 ports
SCG with DB-9 ports
Model Number
SCG-T-EC
SCG-T
First Supported Junos OS
Release
12.1
12.1
20 Copyright © 2018, Juniper Networks, Inc.
Chapter 3: Chassis Components and Description
SCG Components
The SCG with DB-9 ports is shown in
.
Figure 11: SCG with DB-9 Ports
The SCG with RJ-48 ports is shown in
Figure 12: SCG with RJ-48 ports
Online/Offline button
EXTERNAL CLOCK INPUTS
OK Fail Master
Each SCG consists of the following components:
• 19.44-MHz Stratum 3 clock.
• Field-programmable gate array (FPGA) that performs multiplexing of clock sources.
• SCG online/offline button, located on the SCG faceplate.
• Two external clock inputs.
NOTE: The external clock ports are not supported on the SCG with DB-9 ports.
For information about configuring external clock synchronization for T Series routers, see the Junos OS Administration Library .
For information about configuring an interface transmit clock, see the Junos OS Network
Interfaces Library for Routing Devices .
• Three LEDs— OK , FAIL , and MASTER , located on the SCG faceplate, that display the status of the SCG.
Copyright © 2018, Juniper Networks, Inc.
21
T4000 Core Router Hardware Guide
Related
Documentation
•
T4000 SONET Clock Generators (SCGs) LEDs on page 22
• Connecting the T4000 Router to an External Clocking Device
•
Maintaining the T4000 SCGs on page 333
•
Troubleshooting the T4000 SCGs on page 349
T4000 SONET Clock Generators (SCGs) LEDs
Three LEDs, located on the SCG faceplate, display the status of the SCG.
describes the functions of the SCG LEDs. Two LINK LEDs, located on the left of each RJ-48 port, display the status of the external clock inputs links. The other
LEDs on the right of each port are not used.
NOTE: The external clock inputs on the SCG with DB-9 ports are not functional.
shows the LEDs on the SCG with RJ-48 ports.
Figure 13: SCG with RJ-48 ports
Online/Offline button
EXTERNAL CLOCK INPUTS
OK Fail Master
describes the functions of the SCG LEDs. The LINK LED is not applicable to the SCG with DB-9 ports.
Table 5: SCG LEDs
Label Color State Description
OK Green On steadily
FAIL Yellow
Off
On steadily
Off
SCG is online and is functioning normally.
SCG is not online or not functioning normally.
SCG has failed.
SCG is offline or functioning normally.
22 Copyright © 2018, Juniper Networks, Inc.
Chapter 3: Chassis Components and Description
Table 5: SCG LEDs (continued)
Label Color
MASTER
LINK
Blue
Green
State
On steadily
Off
On Steadily
Off
Description
SCG is functioning as master.
SCG is not functioning as the master.
Link is online and active.
No link.
Related
Documentation
•
T4000 SONET Clock Generators (SCGs) Description on page 20
• Connecting the T4000 Router to an External Clocking Device
•
Maintaining the T4000 SCGs on page 333
•
Troubleshooting the T4000 SCGs on page 349
Copyright © 2018, Juniper Networks, Inc.
23
T4000 Core Router Hardware Guide
24 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 4
Cooling System Components and
Descriptions
•
T4000 Cooling System Description on page 25
T4000 Cooling System Description
The cooling system components work together to keep all router components within the acceptable temperature range. The host subsystem monitors the temperature of the router components. When the router is operating normally, the fans function at normal speed. If a fan fails or the ambient temperature rises above a threshold, the speed of the remaining fans is set to full speed. If the ambient maximum temperature specification is exceeded and the system cannot be adequately cooled, the Routing Engine shuts down some or all of the hardware components.
In additions to the fans, the front fan trays are equipped with a fan tray controller (FTC) board. The FTC board is a transition board that distributes the fan-related signals between the Routing Engine and the fans, and controls the speed as required.
•
•
•
•
Power Supply Cooling System on page 27
Airflow
shows the airflow through the router.
Copyright © 2018, Juniper Networks, Inc.
25
T4000 Core Router Hardware Guide
Figure 14: Airflow Through the Chassis
Fan Trays
The cooling system contains the following fan trays:
• One upper front fan tray and one lower front fan tray that cool the components installed in the front card cage (the FPCs, PICs, CIP, and the midplane).
• Rear fan tray containing eight fans.
NOTE: FAN-R-TXP-3D-LCC contains sixteen fans.
The upper and lower front fan trays contain six fans. Both fan trays are interchangeable with each other.
One rear fan tray cools the components installed in the rear card cage (the Routing
Engines, control boards, SCGs, and the SIBs). The rear fan tray is not interchangeable with the front fan trays.
All fan trays are hot-insertable and hot-removable.
CAUTION: To maintain proper cooling, do not operate the routing node with the rear fan tray removed for more than one minute.
The T4000 router supports the fan trays listed in
.
Table 6: T4000 Supported Fan Trays
Name Model Number
First Supported Junos OS
Release
Front Upper Fan Tray
Front Lower Fan Tray
FANTRAY-T4000
FANTRAY-T4000
12.1
12.1
26 Copyright © 2018, Juniper Networks, Inc.
Chapter 4: Cooling System Components and Descriptions
Table 6: T4000 Supported Fan Trays (continued)
Name
Rear Fan Tray
Rear Fan Tray
Model Number
FAN-REAR-TXP-LCC
FAN-R-TXP-3D-LCC
First Supported Junos OS
Release
12.1
13.1
Air Filters
The cooling system contains a front air filter and a rear air filter. All air filters are hot-insertable and hot-removable.
Power Supply Cooling System
Each DC power supply contains two blowers that cool that power supply.
Related
Documentation
•
T4000 Router Description on page 3
•
Maintaining the T4000 Fan Trays on page 335
•
Troubleshooting the T4000 Cooling System on page 351
•
T4000 Router Environmental Specifications on page 88
Copyright © 2018, Juniper Networks, Inc.
27
T4000 Core Router Hardware Guide
28 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 5
Host Subsystem Components and
Descriptions
•
T4000 Host Subsystem Description on page 29
•
T4000 Control Board Description on page 30
•
•
T4000 LCC-CB Control Board LEDs on page 31
•
T4000 Routing Engine Description on page 33
•
T4000 RE-C1800 Routing Engine Description on page 34
•
T4000 RE-C1800 LEDs on page 35
•
Routing Engine Specifications on page 36
•
Supported Routing Engines by Router on page 40
T4000 Host Subsystem Description
The host subsystem provides the routing and system management functions of the router. The host subsystem consists of a Routing Engine and an adjacent control board.
To operate, each host subsystem functions as a unit; the Routing Engine requires the corresponding control board, and vice versa.
NOTE: You can install one or two host subsystems on the router. We recommend that you install two host subsystems for redundant protection.
If you install only one host subsystem, we recommend that you install it in slots RE0 and CB0 .
Each host subsystem has three LEDs, located on the upper right of the craft interface, that display its status. In addition, there are LEDs on each Routing Engine and control board.
Related
Documentation
•
T4000 Routing Engine Description on page 33
•
T4000 RE-C1800 Routing Engine Description on page 34
•
Copyright © 2018, Juniper Networks, Inc.
29
T4000 Core Router Hardware Guide
• T4000 Craft Interface LEDs
•
T4000 RE-C1800 LEDs on page 35
•
T4000 LCC-CB Control Board LEDs on page 31
T4000 Control Board Description
The T4000 chassis supports up to two control boards. The Routing Engine requires an adjacent control board to provide control and monitoring functions for the router. These functions include determining Routing Engine mastership, controlling power and reset for the other router components, monitoring and controlling fan speed, and monitoring system status.
You can install up to two control boards in the chassis. Control boards install into the upper rear of the chassis in the slots labeled CB0 and CB1 (referred to as CB-0 and CB-1 , top to bottom). If two control boards are installed, one functions as the master and the other as its backup. If the master fails or is removed, the backup restarts and becomes the master.
Each control board requires a Routing Engine to be installed in the adjacent slot.
CB0 installs above RE0 , and CB1 installs below RE1 . Control boards cannot function if a Routing
Engine is not present in the adjacent slot.
If the host system is redundant, the backup control board is hot-removable and hot-insertable, but the master control board is hot-pluggable. A control board that is not redundant is hot-pluggable.
The T4000 router supports the control board listed in
Table 7: T4000 Supported Control Board
Name Model Number
First Supported Junos OS
Release
Line-card chassis control board
(LCC-CB)
CB-LCC 12.1
Related
Documentation
•
• T4000 Craft Interface LEDs
•
T4000 LCC-CB Control Board LEDs on page 31
T4000 LCC-CB
Each LCC-CB consists of the following components:
• 100-MB Ethernet switch for intermodule communication.
• PCI bus to the Routing Engines.
30 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
• Switch processor mezzanine board (SPMB).
Figure 15: LCC-CB
The following components are located on the LCC-CB faceplate:
• Two configuration switches:
• The M/S configuration switch must be set to S .
• The CHASSIS ID configuration switch must be set to 0 .
CAUTION: If the configuration switches are set incorrectly, a kernel error occurs during the boot process. Use the show log messages operational-mode CLI command to confirm the error: hostname> show log messages | match error
...
May 21 00:00:00 hostname /kernel: ERROR: CB Chassis number number is invalid
To resolve the error, ensure the switches are set properly, and reboot the router.
• Three LEDs labeled MASTER , FAIL , and OK , which indicate the control board status.
• The online/offline button.
• Six RJ-45 ports labeled SFC0 through SFC5 , which is currently not supported. The two
LEDs for each port labeled LINK and ACT are also not currently supported.
• One JCS port, which is not currently supported. The LINK LED for this port is also not currently supported.
Related
Documentation
•
T4000 Control Board Description on page 30
• T4000 Craft Interface LEDs
•
T4000 LCC-CB Control Board LEDs on page 31
T4000 LCC-CB Control Board LEDs
Status LEDs and port LEDs are located on the faceplate of the LCC-CB (see
Copyright © 2018, Juniper Networks, Inc.
31
T4000 Core Router Hardware Guide
Figure 16: LCC-CB LEDs
Link
LED
Activity
LED
•
•
LCC-CB LEDs
The LEDs located in the middle of the LCC-CB indicate its status.
describes the functions of the LCC-CB LEDs.
Table 8: LCC-CB LEDs
Label Color State Description
MASTER Blue
–
On steadily LCC-CB is functioning as the master.
Off LCC-CB is functioning as the backup.
FAIL
OK
Yellow
–
Green
–
On steadily LCC-CB has failed.
Off No faults have been detected on the LCC-CB.
On steadily LCC-CB is online and is functioning normally.
Blinking
Off
LCC-CB is powering up, but not online.
LCC-CB is offline.
LCC-CB Port LEDs
The six RJ-45 ports labeled SFC0 through SFC4 , the port labeled JCS , and the LEDs for each port labeled LINK or ACT are not currently supported.
Related
Documentation
•
T4000 Host Subsystem Description on page 29
•
T4000 Control Board Description on page 30
• T4000 Craft Interface LEDs
32 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
T4000 Routing Engine Description
The Routing Engine runs Junos OS. The software processes that run on the Routing Engine maintain the routing tables, manage the routing protocols used on the router, control the router interfaces and some chassis components, and provide the interface for system management and user access to the router.
You can install one or two Routing Engines in the router. The Routing Engines install into the upper rear of the chassis in the slots labeled RE0 and RE1 . Each Routing Engine requires a control board to be installed in the adjacent slot.
RE0 installs below CB0 , and RE1 installs above CB1 . A Routing Engine does not power up without a control board present in the adjacent slot.
If two Routing Engines are installed, one functions as the master and the other acts as the backup. If the master Routing Engine fails or is removed and the backup is configured appropriately, the backup takes over as the master. If the host system is redundant, the backup Routing Engine is hot-removable and hot-insertable, but the master Routing
Engine is hot-pluggable. A Routing Engine that is not redundant requires that you power down the router before replacement.
NOTE: For specific information about Routing Engine components (for example, the amount of DRAM), issue the show chassis routing-engine command.
The ports for connecting the Routing Engine to external management devices are located on the Connector Interface Panel (CIP).
The T4000 router supports the Routing Engine in
.
Table 9: T4000 Supported Routing Engines
Name Model Number
First Supported
Junos OS Release
RE-C1800 RE-DUO-C1800-8G
RE-C1800
“T4000 RE-C1800 Routing Engine Description” on page 34
RE-DUO-C1800-16G
NOTE: These Routing Engines require the
LCC-CB when a T4000 router is connected to a TX Matrix Plus router.
12.1
12.1R2
Related
Documentation
•
T4000 Host Subsystem Description on page 29
•
T4000 Control Board Description on page 30
• T4000 Craft Interface LEDs
Copyright © 2018, Juniper Networks, Inc.
33
T4000 Core Router Hardware Guide
•
T4000 Connector Interface Panel (CIP) Description on page 14
T4000 RE-C1800 Routing Engine Description
•
RE-C1800 Routing Engine Components on page 34
•
RE-C1800 Boot Order on page 35
RE-C1800 Routing Engine Components
Each RE-C1800 Routing Engine (
) consists of the following components:
• CPU—Runs Junos OS to maintain the routing tables and routing protocols.
• DRAM—Provides storage for the routing and forwarding tables and for other Routing
Engine processes.
• EEPROM—Stores the serial number of the Routing Engine.
• Interfaces for management access—Provide information about Routing Engine status to devices (console, laptop, or terminal server) connected to the management ports located on the CIP.
Figure 17: RE-C1800
The faceplate of the RE-C1800 contains the following:
• USB port—Provides a removable media interface through which you can install Junos
OS manually. Junos OS supports USB version 1.1 and version 2.0 devices.
• CompactFlash card slot—Provides primary storage for software images, configuration files, and microcode.
• Two solid-state disk (SSD) slots—Provides secondary storage for log files, memory dumps, and rebooting the system if the CompactFlash card fails.
NOTE: DISK2 is not currently supported.
• Reset button—Reboots the Routing Engine when pressed.
• Offline button—Takes the Routing Engine offline when pressed.
• Four LEDs— CF , DISK1 , DISK2 , and ONLINE .
• Extractor clips—Control the locking system that secures the Routing Engine.
34 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
RE-C1800 Boot Order
The RE-C1800 Routing Engine boots from the storage media in this order: the USB device, then the CompactFlash card (if present), then DISK1 , then the LAN.
Related
Documentation
•
T4000 Host Subsystem Description on page 29
•
T4000 Routing Engine Description on page 33
•
T4000 Control Board Description on page 30
• T4000 Craft Interface LEDs
T4000 RE-C1800 LEDs
shows the RE-C1800 LEDs.
describes the functions of the LEDs on the faceplate of the Routing Engine.
Figure 18: RE-C1800 LEDs
CF
D
I
S
K
1
D
I
S
K
2
USB
Online
CF
S
K
D
I
1
D
K
2
I
S
USB
Offline
Online
Reset
Reset
NOTE: The LEDs on the Routing Engine do not necessarily indicate routing-related activity.
Table 10: Routing Engine C1800 LEDs
Label Color State
CF Green On steadily
DISK1
—
Green
—
Off
On steadily
Off
Description
Indicates disk activity on the CompactFlash card.
There is no disk activity on the CompactFlash card.
Indicates activity for the disk.
There is no activity for the disk.
Copyright © 2018, Juniper Networks, Inc.
35
T4000 Core Router Hardware Guide
Table 10: Routing Engine C1800 LEDs (continued)
Label Color State Description
DISK2
ONLINE
Green
—
Green
On steadily
Off
On steadily
Not applicable.
NOTE: The DISK2 LEDis not currently supported.
Routing Engine is functioning normally.
USB
Red
—
Green
—
On steadily
Off
On steadily
Off
Routing Engine is not functioning normally.
Routing Engine is not online or not functioning normally.
Indicates activity on the USB port.
There is no activity on the USB port.
Related
Documentation
•
T4000 Host Subsystem Description on page 29
•
T4000 Routing Engine Description on page 33
•
T4000 RE-C1800 Routing Engine Description on page 34
• T4000 Craft Interface LEDs
Routing Engine Specifications
lists the current specifications for Routing Engines supported on
M Series, MX Series, and T Series routers.
lists the specifications for end-of-life Routing Engines.
NOTE: For a list of the routing engines that are supported on the M Series,
MX Series, T Series, and PTX routers, see
NOTE: For information about PTX Series Routing Engine specifications, see
Routing Engines Supported on PTX Series Routers. For information about
36 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 11: Routing Engine Specifications
Routing
Engine Processor Memory
Connection to PFEs Disk
RE-400-768 400-MHz
Celeron
768 MB Fast
Ethernet
RE-A-1000-2048 1.0-GHz
Pentium
RE-A-2000-4096 2.0-GHz
Pentium
RE-S-1300-2048 1.3-GHz
Pentium
RE-S-2000-4096 2.0-GHz
Pentium
2048 MB
4096 MB
2048 MB
4096 MB
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Media
First Junos OS
Support
40 GB hard disk
1 GB
CompactFlash card
9.0
40 GB hard disk
1 GB
CompactFlash card
8.1
40 GB hard disk
1 GB
CompactFlash card
8.1
40 GB hard disk
1 GB
CompactFlash card
8.2
40 GB hard disk
1 GB
CompactFlash card
8.2
Switch Control
Board
–
–
–
SCB, SCBE
SCB, SCBE
RE-C1800
RE-C2600
1.8-GHz
1.8 Ghz
2.6-GHz
8 GB
16 GB
16 GB
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
SSD
SSD
SSD
4 GB
CompactFlash card
T1600 router in a routing matrix:
9.6R2
Standalone
T640 or T1600 router:11.2
CB-T for a standalone router.
CB-LCC for a router in a routing matrix.
4 GB
CompactFlash card
32-bit Junos OS on a standalone
T1600 router:
11.4R2 32-bit
Junos OS on a
T1600 router in a routing matrix:
11.4R2
CB-T for a standalone router.
CB-LCC for a router in a routing matrix.
64-bit Junos OS on a standalone
T1600 router:
11.4R2 64-bit
Junos OS on a
T1600 router in a routing matrix:
11.4R2
4 GB
CompactFlash card
TX Matrix Plus router: 9.6R2
–
Copyright © 2018, Juniper Networks, Inc.
37
T4000 Core Router Hardware Guide
Table 11: Routing Engine Specifications (continued)
Routing
Engine Processor Memory
Connection to PFEs Disk
RE-A-1800x2 1800-MHz 8 GB or 16
GB
Gigabit
Ethernet
RE-S-1800x2 1800-MHz 8 GB or 16
GB
Gigabit
Ethernet
RE-S-1800x4 1800-MHz 8GB or 16
GB
RE-S-MX104 1.8-GHz
RE-B-1800x1-4G 1.73-GHz
4 GB
4 GB
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Media
First Junos OS
Support
32 GB SSD 4 GB
CompactFlash card
10.4
32 GB SSD 4 GB
CompactFlash card
10.4
32 GB SSD 4 GB
CompactFlash card
10.4
– 8 GB NAND
Flash
13.2
64 GB SSD 4 GB
CompactFlash card
12.1R2, 11.4R4, and 12.2R1
Switch Control
Board
–
SCB, SCBE
SCB, SCBE,
SCBE2
–
–
RE-MX2000-1800x4 1.8- GHz 16 GB Gigabit
Ethernet
RE-S-1800X4-32G-S 1.8- Ghz
REMX2K-1800-32G-S 1.8- Ghz
RE-S-X6-64G 2 Ghz
REMX2K-X8-64G 2.3 Ghz
REMX2008-X8-64G 2.3 Ghz
REMX2008-X8-64G 2.3 Ghz
RE-S-1600x8 1.6 Ghz
32 GB
32 GB
64 GB
64 GB
64 GB
64 GB
64 GB
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
32 GB SSD 4 GB Fixed
Internal
CompactFlash card
12.3R2
32 GB SSD 4 GB Fixed
Internal
CompactFlash card
•
•
12.3R4
13.2R1
SCB, SCBE
SCB, SCBE
SCBE2
32 GB SSD 4GB Fixed
Internal
CompactFlash card
•
•
12.3R4
13.2R1
15.1F4, 16.1
Two 50-GB
SSDs
-
Two
100-GB
SSDs
15.1F5-S1, 16.1R2, and 16.2R1
–
SCBE2
–
Two 50-GB
SSDs
–
Two 50-GB
SSDs
-
Two 50-GB
SSDs
–
15.1F7
15.1F7
17.3R1
–
–
–
38 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 11: Routing Engine Specifications (continued)
Routing
Engine Processor Memory
Connection to PFEs Disk
RE-S-1600x8 1.6 Ghz 64 GB
REMX2008-X8-64G-LT 2.1 Ghz
RE-S-X6-128G 2.1 Ghz
REMX2K-X8-128G 2.1 Ghz
64 GB
128 GB
128 GB
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Media
Two 50-GB
SSDs
–
Two
100-GB
SSDs
Two
100-GB
SSDs
-
Two
100-GB
SSDs
-
18.1R1
18.1R1
First Junos OS
Support
Switch Control
Board
17.3R1
–
17.2R1
-
-
-
NOTE: Use shielded CAT5e cable for connecting the AUX , CONSOLE , and
MGMT ports in RE-S-X6-64G, REMX2K-X8-64G, and REMX2008-X8-64G
Routing Engines.
Table 12: End-of-Life Routing Engine Specifications
Routing
Engine Processor Memory
Connection to PFEs Disk
RE-333-256 333-MHz
Pentium II
256 MB Fast
Ethernet
RE-333-768 333-MHz
Pentium II
768 MB
RE-600-512 600-MHz
Pentium III
512 MB
Fast
Ethernet
Fast
Ethernet
Media
First Junos OS
Support
6.4 GB hard disk
80 MB
CompactFlash card
3.4
6.4 GB hard disk
80 MB
CompactFlash card
3.4
30 GB hard disk
256 MB
CompactFlash card
5.4
EOL Details
PSN-2003-01-063
PSN-2003-01-063
PSN-2004-07-019
RE-600-2048 600-MHz
Pentium III
2048 MB
RE-850-1536 850-MHz
Pentium III
1536 MB
RE-M40 200-MHz
Pentium
256 MB
Fast
Ethernet
Fast
Ethernet
Fast
Ethernet
40 GB hard disk
1 GB
CompactFlash card
5.3
40 GB hard disk
1 GB
CompactFlash card
7.2
6.4 GB hard disk
80 MB
CompactFlash card
3.2
PSN-2008-02-018
PSN-2011-04-226
FA-HW-0101-001
Copyright © 2018, Juniper Networks, Inc.
39
T4000 Core Router Hardware Guide
Table 12: End-of-Life Routing Engine Specifications (continued)
Routing
Engine Processor Memory
Connection to PFEs Disk Media
RE-M40-333-768 333-MHz
Pentium II
768 MB Fast
Ethernet
RE-M40-600-2048 600-MHz
Pentium III
2048 MB
RE-1600-2048 1.6-GHz
Pentium M
2048 MB
Fast
Ethernet
Gigabit
Ethernet
First Junos OS
Support
10 GB hard disk
80 MB
CompactFlash card
4.2
30 GB hard disk
128 MB
CompactFlash card
5.4
40 GB hard disk
1 GB
CompactFlash card
6.2
EOL Details
PSN-2003-01-063
PSN-2004-11-020
PSN-2008-02-019
NOTE: The memory in
indicates the amount of total memory. To determine the amount of available memory, issue the show chassis routing-engine CLI command.
On routers that accept two Routing Engines, you cannot mix Routing Engine types except for a brief period (one minute or so) during an upgrade or downgrade to two Routing
Engines of the same type.
Related
Documentation
•
Supported Routing Engines by Router on page 40
Supported Routing Engines by Router
The following tables list the Routing Engines that each router supports, the first supported release for the Routing Engine in the specified router, the management Ethernet interface, and the internal Ethernet interfaces for each Routing Engine.
•
M7i Routing Engines on page 41
•
M10i Routing Engines on page 41
•
M40e Routing Engines on page 42
•
M120 Routing Engines on page 42
•
M320 Routing Engines on page 43
•
MX5, MX10, MX40, and MX80 Routing Engine on page 43
•
MX104 Routing Engines on page 44
•
MX240 Routing Engines on page 44
•
MX480 Routing Engines on page 45
•
MX960 Routing Engines on page 46
•
MX2008 Routing Engines on page 47
•
MX2010 Routing Engines on page 47
40 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
•
MX2020 Supported Routing Engines on page 48
•
MX10003 Routing Engines on page 49
•
PTX1000 Routing Engines on page 49
•
PTX3000 Routing Engines on page 49
•
PTX5000 Routing Engines on page 50
•
PTX10008 and PTX10016 Routing Engines on page 51
•
T320 Routing Engines on page 51
•
T640 Routing Engines on page 51
•
T1600 Routing Engines on page 52
•
T4000 Routing Engines on page 53
•
TX Matrix Routing Engines on page 54
•
TX Matrix Plus Routing Engines on page 54
•
TX Matrix Plus (with 3D SIBs) Routing Engines on page 54
M7i Routing Engines
lists the Routing Engines supported by the M7i router. The M7i router supports 32-bit Junos OS only.
Table 13: M7i Routing Engines
Model Number
Name in CLI
Output
First Supported 32-bit
Junos OS Release
Management
Ethernet Interface
Internal Ethernet
Interface
RE-5.0
9.0
fxp0 fxp1 RE-400-768 (EOL details:
TSB16445 )
RE-850-1536 (EOL details:
TSB15553 )
RE-B-1800X1-4G
RE-850
RE-B-1800x1
7.2
fxp0 fxp0 fxp1 em0 11.4R4
12.1R2
M10i Routing Engines
lists the Routing Engines supported by the M10i router. The M10i router supports 32-bit Junos OS only.
Table 14: M10i Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
Management
Ethernet Interface
Internal Ethernet
Interface
RE-400-768 (EOL details:
TSB16445 )
RE-5.0
9.0
fxp0 fxp1 fxp2
Copyright © 2018, Juniper Networks, Inc.
41
T4000 Core Router Hardware Guide
Table 14: M10i Routing Engines (continued)
Model Number
RE-850-1536 (EOL details:
TSB15553 )
Name in CLI
Output
RE-850
First Supported
32-bit Junos OS
Release
7.2
Management
Ethernet Interface
Internal Ethernet
Interface fxp0 fxp0 fxp1 fxp2 em0 RE-B-1800X1-4G RE-B-1800x1 11.4R4
12.1R2
M40e Routing Engines
lists the Routing Engines supported by the M40e router.
Table 15: M40e Routing Engines
Model Number Name in CLI Output
First Supported
Junos OS Release
Management
Ethernet Interface
Internal Ethernet
Interface
RE-600-2048 (EOL details:
TSB14373 )
RE-3.0
or RE-3.0
(RE-600)
5.3
fxp0
RE-A-1000-2048 RE-A-1000 8.1
fxp0 fxp1 fxp2 fxp1 fxp2
M120 Routing Engines
lists the Routing Engines supported by the M120 router.
Table 16: M120 Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First
Supported
64-bit Junos
OS Release
Management
Ethernet
Interface
Internal Ethernet
Interface
RE-A-1000-2048 RE-A-1000 8.0R2
– fxp0
RE-A-2000-4096
RE-A-1800X2-8G
RE-A-2000
RE-A-1800x2
8.0R2
•
•
11.4R5
12.1R3
–
10.4
fxp0 fxp0 fxp1 fxp2 em0 bcm0 fxp1 fxp2
42 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 16: M120 Routing Engines (continued)
Model Number
RE-A-1800X2-16G
Name in CLI
Output
RE-A-1800x2
RE-A-1800X4-16G RE-A-1800x4
First Supported
32-bit Junos OS
Release
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
First
Supported
64-bit Junos
OS Release
10.4
10.4
Management
Ethernet
Interface
Internal Ethernet
Interface fxp0 fxp0 fxp1 fxp2 em0 em1
M320 Routing Engines
lists the Routing Engines supported by the M320 router.
Table 17: M320 Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First
Supported
64-bit Junos
OS Release
Management
Ethernet
Interface
Internal Ethernet
Interface
RE-1600-2048 (EOL details: TSB14374 )
RE-4.0
6.2
– fxp0
RE-A-2000-4096
RE-A-1800X2-8G
RE-A-2000
RE-A-1800x2
8.1
•
•
11.4R5
12.1R3
–
10.4
fxp0 fxp0 fxp1 fxp2 em0 bcm0 em0 bcm0
RE-A-1800X2-16G RE-A-1800x2 •
•
11.4R5
12.1R3
10.4
fxp0
RE-A-1800X4-8G RE-A-1800X4 •
•
•
11.4R5
12.1R3
12.2
10.4
fxp0 em0 bcm0 em0 em1
MX5, MX10, MX40, and MX80 Routing Engine
lists the Routing Engines supported by the MX5, MX10, MX40, and
MX80 routers.
Copyright © 2018, Juniper Networks, Inc.
43
T4000 Core Router Hardware Guide
Table 18: MX5, MX10, MX40, and MX80 Routing Engine
Model
Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface Internal Ethernet Interface
Built-in Routing
Engine
Routing Engine
RE-MX80
12.3
fxp0 em0 em1
NOTE: em1 is used to communicate with the
MS-MIC when it is inserted.
MX104 Routing Engines
lists the Routing Engines supported by MX104 routers.
Table 19: MX104 Routing Engines
Model
Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
Internal Ethernet
Interface
RE-S-MX104 Routing Engine 13.2
– fxp0 fxp1 fxp2
MX240 Routing Engines
lists the Routing Engines supported by MX240 routers.
Table 20: MX240 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
Internal Ethernet
Interface
9.0
– fxp0 fxp1 fxp2
RE-S-1300-2048
(EOL details:
TSB16556
RE-S-1300
RE-S-2000-4096
(EOL details:
TSB16735
RE-S-2000
RE-S-1800X2-8G
(EOL details:
TSB16556
RE-S-1800x2
RE-S-1800x2-16G
(EOL details:
TSB16556
RE-S-1800x2
9.0
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
–
10.4
10.4
fxp0 fxp0 fxp0 fxp1 fxp2 em0 em1 em0 em1
44 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 20: MX240 Supported Routing Engines (continued)
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
RE-S-1800X4-8G RE-S-1800X4 •
•
11.4R5
12.1R3
10.4
fxp0
RE-S-1800X4-16G RE-S-1800x4 •
•
11.4R5
12.1R3
10.4
fxp0
•
•
12.3R4
13.2R1
–
Internal Ethernet
Interface em0 em1 em0 em1 em0, em1 ixlv0, igb0
RE-S-1800X4-32G-S RE-S-1800X4
RE-S-X6-64G RE-S-2X00x6
•
•
12.3R4
13.2R1
15.1F4
16.1R1
18.1R1
fxp0 fxp0
RE-S-X6-64G-LT RE-S-2X00x6 -LT – fxp0 ixlv0, igb0 em0
RE-S-X6-128G RE-S-2X00x6-128 – 18.1R1
fxp0 ixlv0, igb0 em0
MX480 Routing Engines
lists the Routing Engines supported by MX480 routers.
Table 21: MX480 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
Internal Ethernet
Interface
8.4
– fxp0 fxp1 fxp2
RE-S-1300-2048
(EOL details:
TSB16556
RE-S-1300
RE-S-2000-4096
(EOL details:
TSB16735
RE-S-2000
RE-S-1800X2-8G
(EOL details:
TSB16556
RE-S-1800x2
RE-S-1800X2-16G
(EOL details:
TSB16556
RE-S-1800x2
8.4
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
–
10.4
10.4
fxp0 fxp0 fxp0 fxp1 fxp2 em0 em1 em0 em1
Copyright © 2018, Juniper Networks, Inc.
45
T4000 Core Router Hardware Guide
Table 21: MX480 Supported Routing Engines (continued)
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
RE-S-1800X4-8G RE-S-1800X4 •
•
11.4R5
12.1R3
10.4
fxp0
RE-S-1800X4-16G RE-S-1800x4 •
•
11.4R5
12.1R3
10.4
fxp0
RE-S-1800X4-32G-S RE-S-1800X4
RE-S-X6-64G RE-S-2X00x6
•
•
12.3R4
13.2R1
–
•
•
12.3R4
13.2R1
15.1F4
16.1R1
18.1R1
fxp0 fxp0
RE-S-X6-64G-LT RE-S-2X00x6 -LT –
RE-S-X6-128G RE-S-2X00x6-128 – 18.1R1
fxp0 fxp0 ixlv0, igb0 em0 ixlv0, igb0 em0
MX960 Routing Engines
lists the Routing Engines supported by MX960 routers.
Table 22: MX960 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First
Supported
64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-S-1300-2048 (EOL details: TSB16556
RE-S-1300 8.2
– fxp0
RE-S-2000-4096 (EOL details: TSB16735
RE-S-1800X2-8G (EOL details: TSB16556
RE-S-2000
RE-S-1800x2
8.2
•
•
11.4R5
12.1R3
–
10.4
fxp0 fxp0 fxp1 fxp2 fxp1 fxp2 em0 em1
RE-S-1800X2-16G (EOL details: TSB16556
RE-S-1800x2 •
•
11.4R5
12.1R3
10.4
fxp0 em0 em1
Internal Ethernet
Interface em0 em1 em0 em1 em0 em1 ixlv0, igb0
46 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 22: MX960 Supported Routing Engines (continued)
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First
Supported
64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-S-1800X4-8G RE-S-1800x4 •
•
11.4R5
12.1R3
10.4
fxp0
RE-S-1800X4-16G RE-S-1800x4 •
•
11.4R5
12.1R3
10.4
fxp0 em0 em1 em0 em1
RE-S-1800X4-32G-S
RE-S-X6-64G
RE-S-1800x4
RE-S-2X00x6
•
•
12.3R4
13.2R1
–
•
•
12.3R4
13.2R1
fxp0 fxp0 em0 em1 ixlv0, igb0
RE-S-2X00x6 –
15.1F4
16.1R1
17.1R1
fxp0 ixlv0, igb0 RE-S-X6-64G (For
MX960-VC)
RE-S-X6-128G RE-S-2X00x6-128 – 18.1R1
fxp0 ixlv0, igb0 em0
MX2008 Routing Engines
lists the Routing Engines supported by MX2008 routers.
Table 23: MX2008 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported 64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
REMX2008-X8-64G RE-MX2008-X8-64G 15.1F7
fxp0
REMX2008-X8-64G-LT REMX2008-X8-64G-LT 17.2R1
fxp0 ixlv0 ixlv1 ixlv0 ixlv1
MX2010 Routing Engines
lists the Routing Engines supported by MX2010 routers.
Copyright © 2018, Juniper Networks, Inc.
47
T4000 Core Router Hardware Guide
Table 24: MX2010 Supported Routing Engines
Model Number
RE-MX2000-1800X4
REMX2K-1800-32G-S
REMX2K-X8-64G
REMX2K-X8-128G
Name in CLI
Output
RE-S-1800x4
RE-S-1800x4
RE-S-2X00x8
First Supported 64-bit Junos
OS Release
Management
Ethernet
Interface
12.3R2
fxp0
•
•
12.3R4
13.2R1
•
•
•
15.1F5-S1
16.1R2
16.2R1
RE-MX200X8-128G 18.1R1
fxp0 fxp0 fxp0
Internal Ethernet
Interface ixlv0 ixlv1 em0 ixlv0 ixlv1 em0 em1 em0 em1
MX2020 Supported Routing Engines
lists the Routing Engines supported by MX2020 routers.
Table 25: MX2020 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported 64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-MX2000-1800X4 RE-S-1800x4 12.3R2
fxp0 em0 em1
REMX2K-1800-32G-S RE-S-1800x4 •
•
12.3R4
13.2R1
fxp0
REMX2K-X8-64G
REMX2K-X8-128G
RE-S-2X00x8 •
•
•
15.1F5-S1
16.1R2
16.2R1
RE-MX200X8-128G 18.1R1
fxp0 fxp0 em0 em1 ixlv0 ixlv1 em0 ixlv0 ixlv1 em0
48 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
MX10003 Routing Engines
lists the Routing Engines supported by MX10003 routers.
Table 26: MX10003 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported 64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
JNP10003-RE1 RE-S-2X00x6 17.3R1
fxp0 em3 em4
PTX1000 Routing Engines
lists the Routing Engine supported on the PTX1000.
NOTE: The PTX1000 supports 64-bit Junos OS only.
Table 27: PTX1000 Routing Engines
Model Number
Name in CLI
Output
Built-in Routing
Engine
RE-PTX1000
First Supported Junos OS
Release
Management
Ethernet Interface
•
•
16.1X65-D30
17.2R1
em0
Internal Ethernet
Interface bme0 em1
PTX3000 Routing Engines
lists the Routing Engines supported on the PTX3000.
Table 28: PTX3000 Routing Engines
Model Number
Name in CLI
Output
RE-DUO-C2600-16G RE-DUO-2600
NOTE: The PTX3000 supports 64-bit Junos OS only.
First Supported Junos OS
Release
13.2R2
Management
Ethernet Interface em0
Internal Ethernet
Interface ixgbe0 ixgbe1
Copyright © 2018, Juniper Networks, Inc.
49
T4000 Core Router Hardware Guide
Table 28: PTX3000 Routing Engines (continued)
Model Number
RCB-PTX-X6-32G
Name in CLI
Output
RE-PTX-2X00x6
First Supported Junos OS
Release
Management
Ethernet Interface
Internal Ethernet
Interface
16.1R4
17.1R1
This Routing Engine does not support Junos OS Release 16.2.
em0 ixlv0 ixlv1
PTX5000 Routing Engines
lists the Routing Engines supported on the PTX5000.
NOTE:
• PTX5000 supports 64-bit Junos OS only.
• The PTX5000 router supports two midplanes. The midplane identified as
Midplane-8S in the CLI output is supported in Junos OS releases, 12.1X48,
12.3, and 13.2. The enhanced midplane, identified as Midplane-8SeP is supported from Junos OS release 14.1 onwards.
The RE-DUO-2600 routing engine with Junos OS 13.2 or earlier is not supported on the PTX5000BASE2 midplane.
Table 29: PTX5000 Routing Engines
Model Number Name in CLI Output
RE-DUO-C2600-16G RE-DUO-2600
First Supported Junos OS
Release
RE-PTX-X8-64G RE-PTX-2X00x8
Management
Ethernet
Interface
12.1X48
12.3
13.2
NOTE: The PTX5000 does not support Junos OS Releases 12.1,
12.2, or 13.1.
em0
15.1F4
16.1R1
em0
RE-PTX-X8-128G RE-PTX-2X00x8-128G 18.1R1
em0 ixlv0 ixlv1 em1 ixlv0 ixlv1 em1
Internal Ethernet
Interface ixgbe0 ixgbe1
50 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
PTX10008 and PTX10016 Routing Engines
lists the Routing Engines supported on the PTX10008 and PTX10016 routers.
Table 30: PTX10008 and PTX10016 Routing Engines
Model Number Name in CLI Output
First Supported
Junos OS Release
Management Ethernet
Interface
Internal Ethernet
Interface
JNP10K-RE0 RE-PTX-2X00x4 17.2R1
em0, em1 bme0 bme1
T320 Routing Engines
lists the Routing Engines supported by the T320 router.
Table 31: T320 Routing Engines
Model Number Name in CLI Output
First Supported
32-bit Junos OS
Release
Management
Ethernet Interface
Internal Ethernet
Interface
RE-600-2048 (EOL details:
TSB14373 )
RE-3.0
or RE-3.0
(RE-600)
5.3
fxp0
RE-1600-2048 (EOL details:
TSB14374
RE-4.0
6.2
fxp0 fxp1 fxp2 fxp1 fxp2
RE-A-2000-4096 RE-A-2000 8.1
fxp0 fxp1 fxp2
The T320 router supports the CB-T control board.
T640 Routing Engines
lists the Routing Engines supported by the T640 router.
Table 32: T640 Routing Engines
Model Number
Name in CLI
Output
First Supported 32-bit
Junos OS Release
First Supported 64-bit
Junos OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-600-2048 (EOL details: TSB14373 )
RE-3.0
or
RE-3.0
(RE-600)
5.3
– fxp0 fxp1 fxp2
Copyright © 2018, Juniper Networks, Inc.
51
T4000 Core Router Hardware Guide
Table 32: T640 Routing Engines (continued)
Model Number
Name in CLI
Output
First Supported 32-bit
Junos OS Release
First Supported 64-bit
Junos OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-1600-2048 (EOL details: TSB14374
RE-4.0
6.2
– fxp0
RE-A-2000-4096 RE-A-2000 8.1
– fxp0 fxp1 fxp2 em0 bcm0 bcm0 em1
RE-DUO-C1800-8G RE-DUO-1800 32-bit Junos OS on a standalone T640 router:
11.2
32-bit Junos OS on a
T640 router in a routing matrix: 11.4R9
64-bit Junos OS on a standalone T640 router:
11.3
em0
64-bit Junos OS on a
T640 router in a routing matrix: 11.4R9
RE-DUO-C1800-16G RE-DUO-1800 32-bit Junos OS on a standalone T640 router:
11.4R2
64-bit Junos OS on a standalone T640 router:
11.4R2
em0
32-bit Junos OS on a
T640 router in a routing matrix: 11.4R9
64-bit Junos OS on a
T640 router in a routing matrix: 11.4R9
bcm0 em1
The T640 standalone router supports CB-T control board and CB-LCC in a T640 routing matrix.
T1600 Routing Engines
lists the Routing Engines supported by the T1600 router.
NOTE: (Two RE-DUO-C1800-8G or two RE-DUO-C1800-16G are required to connect to a Routing Matrix)
Table 33: T1600 Routing Engines
Model Number
Name in CLI
Output
RE-600-2048 (EOL details: TSB14373 )
RE-3.0
or
RE-3.0
(RE-600)
RE-1600-2048 (EOL details: TSB14374
RE-4.0
(RE-1600)
First Supported 32-bit
Junos OS Release
8.5
8.5
First Supported
64-bit Junos OS
Release
–
–
Management
Ethernet
Interface
Internal
Ethernet
Interface fxp0 fxp0 fxp1 fxp2 fxp1 fxp2
52 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 33: T1600 Routing Engines (continued)
Model Number
RE-A-2000-4096
Name in CLI
Output
RE-A-2000
First Supported 32-bit
Junos OS Release
8.5
First Supported
64-bit Junos OS
Release
–
RE-DUO-C1800-8G RE-TXP-LCC or
RE-DUO-1800
32-bit Junos OS on a T1600 router in a routing matrix: 9.6
NOTE: Junos OS Releases
9.6 through 10.4 support
RE-DUO-C1800-8G only during upgrade to a line-card chassis (LCC) in a routing matrix.
32-bit Junos OS on a standalone T1600 router: 11.1
64-bit Junos OS on a
T1600 router in a routing matrix: 9.6
64-bit Junos OS on a standalone T1600 router: 11.1
em0
RE-DUO-C1800-16G RE-DUO-1800 32-bit Junos OS on a standalone T1600 router:
11.4R2
32-bit Junos OS on a T1600 router in a routing matrix:
11.4R2
64-bit Junos OS on a standalone T1600 router: 11.4R2
64-bit Junos OS on a
T1600 router in a routing matrix: 11.4R2
em0
Management
Ethernet
Interface
Internal
Ethernet
Interface fxp0 em0 bcm0 bcm0 em1 bcm0 em1
T4000 Routing Engines
lists the Routing Engines supported by the T4000 router.
NOTE: The T4000 router supports 64-bit Junos OS only.
Table 34: T4000 Routing Engines
Model Number
Name in CLI
Output
RE-DUO-C1800-8G RE-DUO-1800
RE-DUO-C1800-16G RE-DUO-1800
First Supported 64-bit Junos OS
Release
Management
Ethernet
Interface
Standalone T4000 router: 12.1
T4000 router in a routing matrix: 13.1
em0
Standalone T4000 router: 12.1R2
T4000 router in a routing matrix: 13.1
em0
The T4000 router supports the CB-LCC control board.
Internal Ethernet
Interface bcm0 em1 bcm0 em1
Copyright © 2018, Juniper Networks, Inc.
53
T4000 Core Router Hardware Guide
TX Matrix Routing Engines
lists the Routing Engines supported by the TX Matrix router.
Table 35: TX Matrix Routing Engines
Model Number
Name in CLI
Output
First
Supported
32-bit Junos
OS Release
First
Supported
64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-600-2048 (EOL details: TSB14373 )
RE-3.0
or RE-3.0
(RE-600)
7.0
– fxp0
RE-1600-2048 (EOL details: TSB14374
RE-A-2000-4096
RE-DUO-C1800-8G
RE-DUO-C1800-16G
RE-4.0 (RE-1600)
RE-A-2000
RE-DUO-1800
RE-DUO-1800
7.0
8.5
11.4R9
11.4R9
–
–
11.4R9
11.4R9
fxp0 fxp0 em0 em0 fxp1 fxp2 fxp1 fxp2 em0 bcm0 bcm0 em1 bcm0 em1
The TXP router supports two control boards, CB-TX and CB-LCC. The CB-LCC is required for both RE-DUO-C1800-8G and RE-DUO-C1800-16G Routing Engines.
TX Matrix Plus Routing Engines
lists the Routing Engines supported by the TX Matrix Plus router.
Table 36: TX Matrix Plus Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-DUO-C2600-16G RE-TXP-SFC or
RE-DUO-2600
32-bit Junos OS: 9.6
64-bit Junos OS: 11.4
em0 ixgbe0 ixgbe1
The TX Matrix Plus router supports the CB-TXP control board.
TX Matrix Plus (with 3D SIBs) Routing Engines
lists the Routing Engines supported by the TX Matrix Plus router with 3D SIBs.
54 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 37: Routing Engines on TX Matrix Plus with 3D SIBs
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
RE-DUO-C2600-16G RE-TXP-SFC or
RE-DUO-2600
-
Management
Ethernet
Interface
64-bit Junos OS: 11.4
em0
Internal
Ethernet
Interface ixgbe0 ixgbe1
Related
Documentation
•
Routing Engine Specifications on page 36
• Understanding Internal Ethernet Interfaces
• Understanding Management Ethernet Interfaces
Copyright © 2018, Juniper Networks, Inc.
55
T4000 Core Router Hardware Guide
56 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 6
Line Card Components and Descriptions
•
T4000 FPC Description on page 57
•
T4000 FPCs Supported on page 61
•
T4000 PIC Description on page 62
•
T4000 PICs Supported on page 63
•
T4000 End-of-Life PICs Supported on page 67
•
T4000 PIC/FPC Compatibility on page 68
T4000 FPC Description
FPCs are hot-removable and hot-insertable.
•
•
•
T4000 FPC Components on page 58
•
Identifying the FPCs on page 58
•
T4000 FPC Slots
Up to eight FPCs install vertically in the front of the router. The FPC slots are numbered
FPC0 through FPC7 , left to right. If a slot is not occupied by an FPC, an FPC blank panel must be installed to shield the empty slot and to allow cooling air to circulate properly through the router.
T4000 FPC Function
FPCs house the PICs that connect the T4000 Core Router to network media. The main function of an FPC is to connect the PICs installed in it to the other T4000 router components. The Packet Forwarding Engine receives incoming packets from the PICs installed on the FPC and forwards them through the switch planes to the appropriate destination port. In a maximum configuration with eight Type 5 FPCs installed, the Packet
Forwarding Engines can forward up to 4000 million packets per second (Mpps) for all packet sizes. The T4000 Core Router provides up to 2000 gigabits per second (Gbps), full duplex switching (4000 Gbps of any-to-any, nonblocking, half-duplex switching).
Copyright © 2018, Juniper Networks, Inc.
57
T4000 Core Router Hardware Guide
When you install an FPC into a functioning router, the Routing Engine downloads the
FPC software, the FPC runs its diagnostics, and the PICs housed on the FPC are enabled.
Forwarding on other FPCs continues uninterrupted during this process.
T4000 FPC Components
Each FPC consists of the following components:
• FPC card carrier
• One or two Packet Forwarding Engines
• Each T1600-FPC4-ES has two Packet Forwarding Engines. Each Packet Forwarding
Engine consists of Layer 2/Layer 3 Packet Processing ASICs, Switch Interface ASICs,
T Series Internet Processor ASICs, and a Memory Mezzanine Board (MMB) which includes the Queuing and Memory Interface ASICs.
• Each T4000-FPC5-3D or T4000-FPC5-LSR has two Packet Forwarding Engines.
Each Packet Forwarding Engine consists of a Packet Processing ASIC, Interface ASIC, and Switch Interface ASIC.
• Processor Mezzanine Board (PMB), which includes a 1.2-GHz CPU, system controller,
4 GB of DDR3 RAM, and two 10/100/1000Mbps three-speed Ethernet interfaces
• Two LEDs— OK and FAIL —located on the craft interface above the FPC, that display the status of the FPC
• FPC online/offline button, located on the craft interface above the FPC
Identifying the FPCs
Check the label on the faceplate to identify the FPC. See
Table 38: Identifying the FPCs Supported by the Router
FPC Label on the FPC Faceplate
T1600 Enhanced Scaling FPC4
T4000 FPC5
T1600-FPC4
•
•
T4000-FPC5-3D
T4000-FPC5-LSR
58 Copyright © 2018, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
The enhanced scaling T1600-FPC4 is shown in
Figure 19: Enhanced Scaling T1600-FPC4
Copyright © 2018, Juniper Networks, Inc.
59
T4000 Core Router Hardware Guide
The T4000 FPC5 (T4000-FPC5-3D and T4000-FPC5-LSR) is shown in
Figure 20: FPC5 Supported by the Router
12V
300W
FPC Terminology
Regardless of whether you are holding an FPC vertically or horizontally, this document uses the same terms for all four edges of the FPC (see
• Faceplate—Edge of the FPC that has slots into which you insert the PICs
• Connector edge—Edge opposite the faceplate; this edge has the connectors that attach to the midplane
• Top edge—Edge at the top of the FPC when it is vertical
• Bottom edge—Edge at the bottom of the FPC when it is vertical
60 Copyright © 2018, Juniper Networks, Inc.
Figure 21: FPC Edges
Chapter 6: Line Card Components and Descriptions
Related
Documentation
•
T4000 FPCs Supported on page 61
• T4000 Craft Interface LEDs
•
Maintaining T4000 FPCs on page 337
•
Troubleshooting the T4000 FPCs on page 358
T4000 FPCs Supported
T4000 Core Routers support the FPCs listed in
Table 39 on page 61 . You can install any
combination of the following FPCs. The First Junos OS Release Supported column indicates the first release that the FPC is supported in the T4000 router.
Table 39: FPCs Supported by the T4000 Router
FPC
Type FPC Name
FPC Model
Number CLI Name
Maximum
Number of PICs
Maximum
Throughput per
FPC
First Junos OS
Release
Supported
1 Enhanced
Scaling FPC1
T640-FPC1-ES FPC Type 1-ES 4 4 Gbps 12.1R2
2
3
4
Enhanced
Scaling FPC2
Enhanced
Scaling FPC3
T640-FPC2-ES
T640-FPC3-ES
T1600
Enhanced
Scaling FPC4
T1600-FPC4-ES
FPC Type 2-ES
FPC Type 3-ES
FPC Type 4-ES
4
4
2
16 Gbps
40 Gbps
100 Gbps
12.2
12.1R2
12.1
Copyright © 2018, Juniper Networks, Inc.
61
T4000 Core Router Hardware Guide
Table 39: FPCs Supported by the T4000 Router (continued)
FPC
Type
5
FPC Name
Enhanced
Scaling
FPC4-1P
T4000 FPC5
FPC Model
Number CLI Name
T640-FPC4-1P-ES FPC Type 4.1-ES
NOTE: T640-FPC4-ES is not supported.
1
T4000-FPC5-3D FPC Type 5-3D 2
T4000-FPC5-LSR FPC Type 5 -LSR 2
Maximum
Number of PICs
Maximum
Throughput per
FPC
First Junos OS
Release
Supported
100 Gbps 12.1R2
240 Gbps
240 Gbps
12.1
12.3R2
13.1
Related
Documentation
•
T4000 FPC Description on page 57
•
T4000 PIC/FPC Compatibility on page 68
T4000 PIC Description
PICs provide the physical connection to various network media types, receiving incoming packets from the network and transmitting outgoing packets to the network. During this process, each PIC performs framing and line-speed signaling for its media type. Before transmitting outgoing data packets, the PICs encapsulate the packets received from the
FPCs. Each PIC is equipped with an ASIC that performs control functions specific to the media type of that PIC.
The router supports various PICs, including ATM, Ethernet, and SONET/SDH interfaces.
Blank PICs resemble other PICs but do not provide any physical connection or activity.
When a slot is not occupied by a PIC, you must insert a blank PIC to fill the empty slot and ensure proper cooling of the system.
PICs are hot-removable and hot-insertable. Type 1 and Type 2 PICs have captive screws at their upper and lower corners. Type 3 PICs have an upper ejector handle and a lower captive screw. Type 4 and Type 5 PICs have an upper ejector handle and a lower ejector handle.
indicates the number of PICs supported by each FPC.
Table 40: Number of PICs Supported in Each FPC
FPC Name FPC Model Number Maximum Number of PICs
Enhanced Scaling FPC1
Enhanced Scaling FPC2
Enhanced Scaling FPC3
T1600 Enhanced Scaling FPC4
T640-FPC1-ES
T640-FPC2-ES
T640-FPC3-ES
T1600-FPC4-ES
4
2
4
4
62 Copyright © 2018, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 40: Number of PICs Supported in Each FPC (continued)
FPC Name FPC Model Number
Enhanced Scaling FPC4-1P T640-FPC4-1P-ES
NOTE: T640-FPC4-ES is not supported.
1
Maximum Number of PICs
T4000 FPC5
T4000 FPC5
T4000-FPC5-3D
T4000-FPC5-LSR
2
2
Related
Documentation
• T4000 PICs Supported
• Maintaining T4000 PICs
• Troubleshooting T4000 PICs
T4000 PICs Supported
through
list the PICs supported by the T4000 router by PIC family. The First Junos OS Release Support column indicates the first release the PIC was supported on the T4000 router.
•
•
•
Gigabit Ethernet PICs on page 64
•
10-Gigabit Ethernet PICs on page 64
•
40-Gigabit Ethernet PICs on page 65
•
100-Gigabit Ethernet PICs on page 65
•
•
ATM IQ PICs
lists the ATM IQ PICs supported by the T4000 router.
Table 41: ATM IQ PICs Supported in the T4000 Router
PIC Family and Type Ports Model Number Connectors
First Junos OS
Release
Support
ATM2 OC12/STM4 IQ PIC
(T4000 Router)
2 PB-2OC12-ATM2-SMIR Optical: SC 12.2R2
Channelized PICs
lists the Channelized PICs supported by the T4000 router.
Copyright © 2018, Juniper Networks, Inc.
63
T4000 Core Router Hardware Guide
Table 42: Channelized PICs Supported in the T4000 Router
PIC Family and Type
Channelized DS3 IQ PIC
(T4000 Router)
Channelized DS3/E3 Enhanced
IQ (IQE) PIC (T4000 Router)
4
Channelized OC12/STM4
Enhanced IQ (IQE) PICs with
SFP (T4000 Router)
4
4
Channelized OC48/STM16
Enhanced IQ (IQE) PIC with
SFP (T4000 Router)
1
Ports
4
Model Number
PB-4CHDS3-QPP
PB-4CHDS3-E3-IQE-BNC
PB-4CHOC12-STM4-IQE-SFP
PC-4CHOC12-STM4-IQE-SFP
PB-1CHOC48-STM16-IQE-SFP
Connectors
Coaxial
Coaxial
Optical: LC
Optical: LC
Optical: LC
First Junos OS
Release
Support
12.1R2
12.1.R2
12.2R1
13.2
12.2R1
Gigabit Ethernet PICs
lists the Gigabit Ethernet PICs supported by the T4000 router.
Table 43: Gigabit Ethernet PICs Supported in the T4000 Router
PIC Family and Type Ports Model Number Connectors
First Junos OS
Release
Support
Gigabit Ethernet PICs with SFP
(T4000 Router)
2
4
Gigabit Ethernet IQ PIC with
SFP (T4000 Router)
Gigabit Ethernet IQ2 PICs with
SFP (T4000 Router)
8
8
Gigabit Ethernet Enhanced IQ2
(IQ2E) PIC with SFP (T4000
Router)
8
10
2
PB-2GE-SFP
PB-4GE-SFP
PC-10GE-SFP
PB-2GE-SFP-QPP
PC-8GE-TYPE3-SFP-IQ2
PB-8GE-TYPE2-SFP-IQ2
PC-8GE-TYPE3-SFP-IQ2E
Optical: LC
Optical: LC
Optical: LC
Optical: LC
Optical: LC
Optical: LC
Optical: LC
12.2R2
12.2R2
12.1R2
12.2R2
12.1R2
12.2R2
12.1R2
10-Gigabit Ethernet PICs
lists the 10-Gigabit Ethernet PICs supported by the T4000 router.
64 Copyright © 2018, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 44: 10-Gigabit Ethernet PICs Supported in the T4000 Router
PIC Family and Type
10-Gigabit Ethernet PIC with
XENPAK (T4000 Router)
1
Ports
10-Gigabit Ethernet IQ2 PIC with XFP (T4000 Router)
1
10-Gigabit Ethernet IQ2E PIC with XFP (T4000 Router)
1
10-Gigabit Ethernet LAN/WAN
PIC with SFP+ (T4000 Router)
12
10-Gigabit Ethernet LAN/WAN
PIC with Oversubscription and
SFP+ (T4000 Router)
10
24
10-Gigabit Ethernet LAN/WAN
PIC with XFP (T4000 Router)
4
Model Number
PC-1XGE-XENPAK
PC-1XGE-TYPE3-XFP-IQ2
PC-1XGE-TYPE3-XFP-IQ2E
PF-12XGE-SFPP
PD-5-10XGE-SFPP
PF-24XGE-SFPP
PD-4XGE-XFP
Connectors
Optical: SC
Optical: LC
Optical: LC
Optical: LC
Optical: LC
Optical: LC
Optical: LC
First Junos OS
Release
Support
12.2R2
12.1R2
12.1R2
12.1
12.1R2
12.2
12.1R2
40-Gigabit Ethernet PICs
lists the 40-Gigabit Ethernet PICs supported by the T4000 router.
Table 45: 40-Gigabit Ethernet PICs Supported in the T4000 Router
PIC Family and Type Ports Model Number Connectors
First Junos OS
Release
Support
40-Gigabit Ethernet PIC with
CFP (T4000 Router)
4 PD-1XLE-CFP Optical: SC 13.2
100-Gigabit Ethernet PICs
lists the 100-Gigabit Ethernet PICs supported by the T4000 router.
Copyright © 2018, Juniper Networks, Inc.
65
T4000 Core Router Hardware Guide
Table 46: 100-Gigabit Ethernet PICs Supported in the T4000 Router
PIC Family and Type
100-Gigabit Ethernet PIC with
CFP (T4000 Router)
1
1
Ports Model Number
PF-1CGE-CFP
Connectors
First Junos OS
Release
Support
Optical: SC, LC, or
24-fiber MPO depending on the transceiver. See the
PIC description for more information.
12.1
PD-1CE-CFP-FPC4 (PIC and FPC)
NOTE: This PIC is available only packaged in an assembly with the
T1600-FPC4-ES FPC.
Optical: SC, LC, or
24-fiber MPO depending on the transceiver. See the
PIC description for more information.
12.1R2
Services PICs
lists the services PICs supported by the T4000 router.
Table 47: Services PICs Supported in the T4000 Router
PIC Family and Type Ports Model Number Connectors
First Junos OS
Release
Support
MultiServices PICs (T4000
Router)
Tunnel Services PICs (T4000
Router)
0
0
0
0
PB-MS-400-2
PB-MS-500-3
PC-TUNNEL
PB-TUNNEL
None
None
None
None
12.2
12.1R2
12.1R2
12.2R2
SONET/SDH PICs
lists the SONET/SDH PICs supported by the T4000 router.
Table 48: SONET/SDH PICs Supported in the T4000 Router
PIC Family and Type Ports Model Number Connectors
First Junos OS
Release
Support
4 PB-4OC3-1OC12-SON2-SFP Optical: LC 12.2R2
SONET/SDH OC3/STM1
(Multi-Rate) PICs with SFP
(T4000 Router)
SONET/SDH OC12/STM4
(Multi-Rate) PICs with SFP
(T4000 Router)
4 PB-4OC3-4OC12-SON-SFP Optical: LC 12.2R2
66 Copyright © 2018, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 48: SONET/SDH PICs Supported in the T4000 Router (continued)
PIC Family and Type Ports
SONET/SDH OC48c/STM16
PIC with SFP (T4000 Router)
4
SONET/SDH OC48/STM16
Enhanced IQ (IQE) PIC with
SFP (T4000 Router)
SONET/SDH OC48/STM16
(Multi-Rate) PIC with SFP
(T4000 Router)
1
SONET/SDH OC192/STM64
PICs with XFP (T4000 Router)
1
4
1
4
SONET/SDH OC768c/STM256
PIC (T4000 Router)
1
Model Number
PC-4OC48-SON-SFP
PB-1OC48-SON-SMSR
PC-4OC48-STM16-IQE-SFP
PB-1OC48-SON-B-SFP
PC-1OC192-SON-XFP
PD-4OC192-SON-XFP
PD-1OC768-SON-SR
Connectors
Optical: LC
Optical: SC
Opticl: LC
Optical: LC
Optical: LC
Optical: LC
Optical: SC
First Junos OS
Release
Support
12.1R2
12.2R2
13.2
12.2R2
12.1R2
12.1
12.1
Related
Documentation
•
T4000 PIC Description on page 62
•
T4000 End-of-Life PICs Supported on page 67
•
T4000 PIC/FPC Compatibility on page 68
T4000 End-of-Life PICs Supported
lists the end-of-life PICs supported by the T4000 router. The PICs are listed alphabetically by PIC family.
NOTE: End-of-life (EOL) indicates that the product has been removed from the price list and is no longer available for purchase. End-of-support (EOS) indicates that no new support contracts are available on these products and the last contract will expire on the EOS date associated with each product.
Table 49: End-of-Life PICs Supported in the T4000 Router
PIC Family and Type
10-Gigabit Ethernet DWDM OTN EOL PIC
(T4000 Router)
1
Ports Model Number
PC-1XGE-DWDM-OTN
Connectors
Optical: SC
First Junos OS
Release Support
12.1R2
Copyright © 2018, Juniper Networks, Inc.
67
T4000 Core Router Hardware Guide
Table 49: End-of-Life PICs Supported in the T4000 Router (continued)
PIC Family and Type
SONET/SDH OC12c/STM4 EOL PIC
(T4000 Router)
SONET/SDH OC48c/STM16 EOL PICs
(T4000 Router)
SONET/SDH OC48c/STM16 EOL PIC with SFP (T4000 Router)
SONET/SDH OC192/STM64 EOL PIC
(T4000 Router)
1
1
1
Ports Model Number
4
4
PB-4OC12-SON-MM
PB-4OC12-SON-SMIR
PC-4OC48-SON-SMSR
PB-1OC48-SON-SMSR
PB-1OC48-SON-SFP
PC-1OC192-SON-SR2
Connectors
Optical: SC
Optical: SC
Optical: SC
Optical: LC
Optical: SC
First Junos OS
Release Support
12.2R2
12.1R2
12.2R2
12.2R2
12.1R2
Related
Documentation
•
T4000 PIC Description on page 62
•
T4000 PICs Supported on page 63
•
T4000 PIC/FPC Compatibility on page 68
T4000 PIC/FPC Compatibility
The PIC/FPC compatibility matrixes list the current PICs for the T4000 router. For example, Junos OS Release 12.1 is the first release in which the T1600-FPC4-ES supports the OC192/STM64, 4-port PIC in the T4000 router.
•
PIC/FPC Compatibility (Type 1) on page 68
•
PIC/FPC Compatibility (Type 2) on page 70
•
PIC/FPC Compatibility (Type 3) on page 71
•
PIC/FPC Compatibility (Type 4) on page 73
•
PIC/FPC Compatibility (Type 5) on page 73
PIC/FPC Compatibility (Type 1)
provides a PIC/FPC compatibility matrix for the current Type 2 PICs for the T4000 router and Type 2 FPCs.
Table 50: T4000 PIC/FPC Compatibility Type 1
Type 1 PIC PIC Model Number T640-FPC1-ES
Channelized IQ PICs
Channelized DS3 IQ PIC (T4000
Router)
PB-4CHDS3-QPP 12.1R2
68 Copyright © 2018, Juniper Networks, Inc.
Table 50: T4000 PIC/FPC Compatibility Type 1 (continued)
Type 1 PIC PIC Model Number
Channelized OC3 IQ PIC (T4000
Router)
PB-1CHOC3-SMIR-QPP
Channelized STM1 IQ PIC (T4000
Router)
PB-1CHSTM1-SMIR-QPP
Channelized IQE PICs
Channelized DS3/E3 Enhanced IQ
(IQE) PIC (T4000 Router)
PB-4CHDS3-E3-IQE-BNC
Channelized E1/T1 Enhanced IQ
(IQE) PIC (T4000 Router)
PB-1OCHE1-T1-IQE-RJ48
Channelized OC3/STM1 Enhanced
IQ (IQE) PIC with SFP (T4000
Router)
PB-2CHOC3-STM1-IQE-SFP
Channelized OC12/STM4 Enhanced
IQ (IQE) PICs with SFP (T4000
Router)
PB-1CHOC12-STM4-IQE-SFP
DS3 and E3 PICs
DS3/E3 Enhanced IQ (IQE) PIC
(T4000 Router)
PB-4DS3-E3-IQE-BNC
Fast Ethernet and Gigabit Ethernet PICs
Fast Ethernet PIC (T4000 Router) PB-4FE-TX
Gigabit Ethernet PICs with SFP
(T4000 Router)
PB-1GE-SFP
Gigabit Ethernet IQ2 PICs
Gigabit Ethernet IQ2 PICs with SFP
(T4000 Router)
PB-4GE-TYPE1-SFP-IQ2
Gigabit Ethernet IQ2E PICs
Gigabit Ethernet Enhanced IQ2
(IQ2E) PIC with SFP (T4000
Router)
PB-4GE-TYPE1-SFP-IQ2E
Services PICs
Tunnel Services PICs (T4000
Router)
SONET/SDH PICs
PB-TUNNEL1
Copyright © 2018, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
12.1.R2
12.1.R2
12.1.R2
12.1.R2
12.1.R2
12.1.R2
T640-FPC1-ES
12.1.R2
12.1.R2
12.1.R2
12.1.R2
12.1.R2
12.1.R2
69
T4000 Core Router Hardware Guide
Table 50: T4000 PIC/FPC Compatibility Type 1 (continued)
Type 1 PIC PIC Model Number
SONET/SDH OC3/STM1
(Multi-Rate) PICs with SFP (T4000
Router)
PB-4OC3-1OC12-SON-SFP
SONET/SDH OC12/STM4
(Multi-Rate) PICs with SFP (T4000
Router)
PB-1OC12-SON-SFP
T640-FPC1-ES
12.1.R2
12.1.R2
PIC/FPC Compatibility (Type 2)
provides a PIC/FPC compatibility matrix for the current Type 2 PICs for the T4000 router and Type 2 FPCs.
Table 51: T4000 PIC/FPC Compatibility Type 2
Type 2 PIC PIC Model Number T640-FPC2-ES
ATM PICs
ATM2 OC12/STM4 IQ PIC (T4000
Router)
PB-2OC12-ATM2-SMIR
Channelized IQ PICs
Channelized OC12/STM4 Enhanced
IQ (IQE) PICs with SFP (T4000
Router)
PB-4CHOC12-STM4-IQE-SFP
Channelized OC48/STM16
Enhanced IQ (IQE) PIC with SFP
(T4000 Router)
PB-1CHOC48-STM16-IQE-SFP
Gigabit Ethernet PICs
Gigabit Ethernet PICs with SFP
(T4000 Router)
PB-2GE-SFP
PB-4GE-SFP
PB-2GE-SFP-QPP Gigabit Ethernet IQ PIC with SFP
(T4000 Router)
Gigabit Ethernet IQ2 PICs with SFP
(T4000 Router)
PB-8GE-TYPE2-SFP-IQ2
Services PICs
MultiServices PICs (T4000 Router) PB-MS-400-2
Tunnel Services PICs (T4000
Router)
PB-TUNNEL
SONET/SDH PICs
12.2.R1
12.2R2
12.2R2
12.2R2
12.2R2
12.2R2
12.2R2
12.2
12.2R2
70 Copyright © 2018, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 51: T4000 PIC/FPC Compatibility Type 2 (continued)
Type 2 PIC PIC Model Number
SONET/SDH OC3/STM1
(Multi-Rate) PICs with SFP (T4000
Router)
PB-4OC3-1OC12-SON2-SFP
SONET/SDH OC12c/STM4 EOL PIC
(T4000 Router)
PB-4OC12-SON-MM
PB-4OC12-SON-SMIR
SONET/SDH OC12/STM4
(Multi-Rate) PICs with SFP (T4000
Router)
PB-4OC3-4OC12-SON-SFP
SONET/SDH OC48c/STM16 EOL
PICs (T4000 Router)
PC-4OC48-SON-SMSR
PB-1OC48-SON-SMSR
SONET/SDH OC48c/STM16 EOL
PIC with SFP (T4000 Router)
PB-1OC48-SON-SFP
SONET/SDH OC48/STM16
(Multi-Rate) PIC with SFP (T4000
Router)
PB-1OC48-SON-B-SFP
T640-FPC2-ES
12.2R2
12.2R2
12.2R2
12.1R2
12.2R2
12.2R2
12.2R2
PIC/FPC Compatibility (Type 3)
provides a PIC/FPC compatibility matrix for the current Type 3 PICs for the T4000 router and Type 3 FPCs.
Table 52: T4000 PIC/FPC Compatibility Type 3
Type 3 PIC PIC Model Number T640-FPC3-ES
Channelized IQE
Channelized OC12/STM4 Enhanced
IQ (IQE) PICs with SFP (T4000
Router)
PC-4CHOC12-STM4-IQE-SFP
Gigabit Ethernet PICs
Gigabit Ethernet PICs with SFP
(T4000 Router)
PC-10GE-SFP
Gigabit Ethernet IQ2 PICs with SFP
(T4000 Router)
PC-8GE-TYPE3-SFP-IQ2
Gigabit Ethernet Enhanced IQ2
(IQ2E) PIC with SFP (T4000
Router)
PC-8GE-TYPE3-SFP-IQ2
13.2
12.1R2
12.1R2
12.1R2
Copyright © 2018, Juniper Networks, Inc.
71
T4000 Core Router Hardware Guide
Table 52: T4000 PIC/FPC Compatibility Type 3 (continued)
Type 3 PIC PIC Model Number
10-Gigabit Ethernet PICs
10-Gigabit Ethernet PIC with
XENPAK (T4000 Router)
10-Gigabit Ethernet DWDM OTN
EOL PIC (T4000 Router)
PC-1XGE-XENPAK
PC-1XGE-DWDM-OTN
10-Gigabit Ethernet IQ2 PIC with
XFP (T4000 Router)
PC-1XGE-TYPE3-XFP-IQ2
10-Gigabit Ethernet IQ2E PIC with
XFP (T4000 Router)
PC-1XGE-TYPE3-XFP-IQ2E
Services PICs
MultiServices PICs (T4000 Router) PC-MS-500-3
Tunnel Services PICs (T4000
Router)
PC-TUNNEL
SONET/SDH PICs
SONET/SDH OC48c/STM16 EOL
PICs (T4000 Router)
SONET/SDH OC48c/STM16 PIC with SFP (T4000 Router)
PC-4OC48-SON-SMSR
PC-4OC48-SON-SFP
SONET/SDH OC48/STM16
Enhanced IQ (IQE) PIC with SFP
(T4000 Router)
PC-4OC48-STM16-IQE-SFP
SONET/SDH OC192/STM64 PICs with XFP (T4000 Router)
PC-1OC192-SON-XFP
12.1R2
12.1R2
12.1R2
12.1R2
13.2
13.2
T640-FPC3-ES
12.2R2
12.1R2
12.1R2
12.1R2
72 Copyright © 2018, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
PIC/FPC Compatibility (Type 4)
provides a PIC/FPC compatibility matrix for the current Type 4 PICs for the T4000 router and Type 4 FPCs.
Table 53: T4000 PIC/FPC Compatibility Type 4
Type 4 PIC PIC Model Number T640-FPC4-1P-ES T1600-FPC4-ES
10-Gigabit Ethernet PICs
10-Gigabit Ethernet LAN/WAN PIC with Oversubscription and SFP+
(T4000 Router)
PD-5-10XGE-SFPP 12.1R2
12.1R2
12.1
NOTE: To support
PD-5-10XGE-SFPP, the hardware version of the
T1600-FPC4-ES
(part number
710-013037) REV 13 or later is required.
12.1
10-Gigabit Ethernet LAN/WAN PIC with XFP (T4000 Router)
PD-4XGE-XFP
40-Gigabit Ethernet PICs
40-Gigabit Ethernet PIC with CFP
(T4000 Router)
PD-1XLE-CFP
100-Gigabit Ethernet PICs
100-Gigabit Ethernet PIC with CFP
(T4000 Router)
PD-1CE-CFP-FPC4 (PIC and FPC)
NOTE: This PIC is available only packaged in an assembly with the
T1600-FPC4-ES FPC.
SONET/SDH PICs
SONET/SDH OC192/STM64 PICs with XFP (T4000 Router)
PD-4OC192-SON-XFP
SONET/SDH OC768c/STM256 PIC
(T4000 Router)
PD-1OC768-SON-SR
—
—
12.1R2
12.1R2
13.2
12.1R2
12.1
12.1
PIC/FPC Compatibility (Type 5)
provides a PIC/FPC compatibility matrix for the current Type 5 PICs for the T4000 router and Type 5 FPCs.
Table 54: T4000 PIC/FPC Compatibility Type 5
Type 5 PIC PIC Model Number T4000-FPC5-3D T4000-FPC5-LSR
10-Gigabit Ethernet PICs
Copyright © 2018, Juniper Networks, Inc.
73
T4000 Core Router Hardware Guide
Table 54: T4000 PIC/FPC Compatibility Type 5 (continued)
Type 5 PIC PIC Model Number
10-Gigabit Ethernet LAN/WAN PIC with SFP+ (T4000 Router)
PF-12XGE-SFPP
10-Gigabit Ethernet LAN/WAN PIC with Oversubscription and SFP+
(T4000 Router)
PF-24XGE-SFPP
100-Gigabit Ethernet PICs
100-Gigabit Ethernet PIC with CFP
(T4000 Router)
PF-1CGE-CFP
Related
Documentation
•
T4000 PIC Description on page 62
•
T4000 PICs Supported on page 63
•
T4000 FPCs Supported on page 61
T4000-FPC5-3D T4000-FPC5-LSR
12.1
12.3R2
12.2
12.3R2
12.1
12.3R2
74 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 7
Power System Components and
Descriptions
•
T4000 Power System Description on page 75
•
T4000 Six-Input DC Power Supply LEDs on page 77
T4000 Power System Description
•
•
Power Supply Function on page 75
•
Supported Power Supplies on page 75
•
Power Supply Components on page 76
•
Power Supply Slots
The T4000 router has two redundant, load-sharing power supplies, located at the lower rear of the chassis in slots PEM0 and PEM1 (top to bottom). Power supplies are hot-removable and hot-insertable.
Power Supply Function
The power supplies connect to the midplane, which distributes the different output voltages produced by the power supplies to the T4000 router components, depending on their voltage requirements.
Supported Power Supplies
The T4000 router supports the power supply in
Table 55: Supported Power Supplies
Name Model Number
First Supported Junos OS
Release
Six-input DC power supply PWR-T-6-60-DC 12.1
Copyright © 2018, Juniper Networks, Inc.
75
T4000 Core Router Hardware Guide
Power Supply Components
Each six-input DC power supply weighs approximately 39.7 lb (18.0 kg) and consists of six inputs, two blowers, a front and side air filter, and LEDs to monitor the status of the power supply. Each power supply is cooled by its own internal cooling system.
shows the six-input DC power supply.
The six-input DC power supply inputs are labeled INPUT 0 , INPUT 1 , INPUT 2 , INPUT 3 ,
INPUT 4 , and INPUT 5 , from top to bottom. Each 60 A input consists of –48 VDC and return.
NOTE: There are no circuit breakers or passive fuses in the router.
Figure 22: DC Power Supply
Redundancy
describes which components are powered by each input.
Table 56: Components Powered by Each Six-Input DC Power Supply Input
Input Components
Fan trays INPUT 0
INPUT 1 through INPUT 5 FPCs, Routing Engines, control boards, SIBs, craft interface, SCGs, and other components in the router.
When the T4000 router is operating normally and both power supplies are switched on, load sharing between them occurs automatically. When one power supply fails or is turned off, the other power supply immediately assumes the entire electrical load for the system. A single power supply can provide full power for as long as the router is operational. For power management of the T4000 router, see
Management (Three 80-A Cables on a Six-Input DC Power Supply)” on page 103
and
“T4000 Power Management (Four 60-A Cables on a Six-Input DC Power Supply)” on page 103 .
76 Copyright © 2018, Juniper Networks, Inc.
Chapter 7: Power System Components and Descriptions
Related
Documentation
•
T4000 Six-Input DC Power Supply LEDs on page 77
•
Maintaining the T4000 Power System on page 338
•
Troubleshooting the T4000 Power System on page 363
T4000 Six-Input DC Power Supply LEDs
The LEDs on the faceplate of each power supply (see
) indicate the status of the power supply. The DC OK , OVERTEMP , and INPUT PRESENT LEDs are located on the faceplate of the power supply. A power supply failure also triggers the red alarm
LED on the craft interface.
describes the six-input DC power supply LEDs on the faceplate.
Table 57: Power Supply LEDs
LED Color State Description
INPUT
PRESENT —One per input
Green
–
On steadily
Off
Input is receiving voltage within the required range of –40 V through
–72 V.
Input voltage is not present, or the voltage is not within the required range of –40 V through –72 V.
DC OK —One per power supply
Blue
–
OVERTEMP —One per power supply
Yellow
–
On steadily
Off
On steadily
Off
When input 0 and at least one other input is properly energized and the power switch is ON, this input indicates that the power supply is functioning normally.
Power supply is starting up or is not receiving any input voltage.
The power switch on the power supply faceplate or the customer site external circuit breakers might be off. A fault might have occurred.
Power supply has exceeded the recommended temperature and has been powered off.
The power supply is within the recommended temperature, or the power supply is not receiving any input voltage.
Related
Documentation
•
T4000 Power System Description on page 75
•
Maintaining the T4000 Power System on page 338
•
Troubleshooting the T4000 Power System on page 363
Copyright © 2018, Juniper Networks, Inc.
77
T4000 Core Router Hardware Guide
78 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 8
Switch Fabric Components and
Descriptions
•
T4000 Switch Interface Board (SIB) Description on page 79
•
T4000-SIB Description on page 80
•
T4000 TXP-LCC-3D SIB Description on page 80
•
T4000 Switch Interface Board (SIB) Description
SIBs create the switch fabric for the T4000 Core Router. Each T4000 router contains five SIBs, located at the center rear of the chassis in the slots labeled SIB0 through SIB4
(top to bottom). One of the five SIBs acts as a backup to the remaining four SIBs. If a SIB fails, the backup SIB becomes active, and traffic forwarding continues without any degradation. When the failed SIB is replaced, it becomes the new backup. SIBs are hot-insertable and hot-removable.
The T4000 router supports the SIB listed in
.
Table 58: T4000 Supported SIB
Name Model Number First Supported Junos OS Release
12.1
T4000-SIB
NOTE: This SIB is required for a standalone T4000 router.
SIB-I-T4000
TXP-LCC-3D SIB
NOTE: This SIB is required for a
T4000 line-card chassis connected to a TX Matrix Plus Router.
SIB-TXP-3D-LCC 13.1
Related
Documentation
•
T4000-SIB Description on page 80
•
T4000 TXP-LCC-3D SIB Description on page 80
•
T4000 Router Description on page 3
Copyright © 2018, Juniper Networks, Inc.
79
T4000 Core Router Hardware Guide
T4000-SIB Description
shows a T4000-SIB that is required for a standalone T4000 router.
Figure 23: T4000-SIB
Each T4000-SIB consists of the following components:
• Switch fabric ASICs.
• High-speed links to each FPC.
• SIB online/offline button, located on the SIB faceplate. The button is to signal a removal request by a user.
• Three LEDs— ACTIVE , OK , and FAIL —located on the SIB faceplate that display the status of the T4000-SIB. The OK and FAIL LEDs are replicated on the craft interface.
Related
Documentation
•
T4000 Switch Interface Board (SIB) Description on page 79
•
•
Maintaining the T4000 SIBs on page 339
•
Replacing a T4000-SIB on page 319
T4000 TXP-LCC-3D SIB Description
shows a TXP-LCC-3D SIB (model number SIB-TXP-3D-LCC) that is required to connect a T4000 line card chassis (LCC) to TXP-F13-3D SIBs in a TX Matrix
Plus router. See TX Matrix Plus Router Hardware Guide .
Figure 24: TXP-LCC-3D SIB
SIB status
LEDs
ONLINE/
OFFLINE button
ONLINE/
OFFLINE
OK
FAIL
ACTIVE
Ports: 0 1 2 3 4 5 6 7 Port LEDs
80 Copyright © 2018, Juniper Networks, Inc.
Chapter 8: Switch Fabric Components and Descriptions
Each TXP-LCC-3D SIB consists of the following components:
• Eight ports labeled 0 through 7 . Each port has a CBL and LINK LED.
• Switch fabric ASICs.
• High-speed links to each FPC.
• SIB online/offline button, located on the SIB faceplate. The button is to signal a removal request by a user.
• Three LEDs— OK , FAIL , and ACTIVE —located on the SIB faceplate that display the status of the TXP-LCC-3D SIB. The OK and FAIL LEDs are replicated on the craft interface.
Related
Documentation
•
T4000 Switch Interface Board (SIB) Description on page 79
•
•
Maintaining the T4000 SIBs on page 339
•
Replacing a T4000-SIB on page 319
T4000 SIB LEDs
describes the functions of the T4000-SIB LEDs and TXP-LCC-3D
SIB LEDs. If all three LEDs are off, the SIB is not receiving power. The craft interface has three additional LEDs that show the status of each SIB.
Table 59: T4000 and TXP-LCC-3D SIB LEDs
Label Color State Description
ACTIVE Green
OK Green
On steadily
Off
On steadily
Blinking
Off
SIB is in active mode.
SIB is in standby mode.
NOTE: This LED has significance only if the ONLINE LED is lit.
SIB is functioning normally.
SIB is starting up.
SIB has been inserted or is ready for removal.
FAIL Red On steadily
Off
SIB has failed.
SIB is functioning normally.
The TXP-LCC-3D SIB port LEDs are located beneath each port (see
Each port has a Link and CBL LED.
describes the functions of these
LEDs.
Copyright © 2018, Juniper Networks, Inc.
81
T4000 Core Router Hardware Guide
Figure 25: TXP-3D-LCC SIB LEDs
OK
FAIL
ACTIVE
OK
FAIL
ACTIVE
ONLINE/
OFFLINE
Table 60: TXP-LCC-3D SIB Port LEDs
Label Color State
LINK Green On steadily
Yellow
Red
–
CBL Green
Yellow
Red
Off
Blinking
On steadily
Blinking
On steadily
Off
On steadily
On steadily
Off
–
Description
The link between the TXP-F13-3D SIB port and the TXP-LCC-3D SIB port has been established successfully.
The link between the TXP-LCC-3D SIB port and the loopback connector has been established successfully.
The link is being established.
The switching plane cable might be connected to either the wrong TXP-LCC-3D
SIB port or the wrong TXP-FI3-3D port.
The link between the TXP-F13-3D SIB port and the TXP-LCC-3D SIB port failed.
There might be a hardware problem, or the fiber-optic port or cable might need to be cleaned.
The cable is not connected on both sides, or either the TXP-F13-3D SIB or the
TXP-LCC-3D SIB is powered off.
Full optical power is being received.
Diminished optical power is being received. The switching plane cable or the switching plane port might need cleaning, or the cable might be damaged.
Optical power has crossed operating thresholds. The switching plane cable is not connected to the TXP-FI3-3D SIB port, or is not connected to the TXP-LCC-3D
SIB port. If the cable is connected on both sides, the cable might be cut.
No optical power is detected. Cable is damaged or absent.
82 Copyright © 2018, Juniper Networks, Inc.
Chapter 8: Switch Fabric Components and Descriptions
Related
Documentation
•
T4000 Switch Interface Board (SIB) Description on page 79
•
T4000 TXP-LCC-3D SIB Description on page 80
Copyright © 2018, Juniper Networks, Inc.
83
T4000 Core Router Hardware Guide
84 Copyright © 2018, Juniper Networks, Inc.
PART 2
Site Planning, Preparation, and
Specifications
•
Planning and Preparing the Site on page 87
•
Calculating System Power Requirements on page 97
•
DC Power Specifications A on page 101
•
Network Cable and Transceiver Planning on page 109
•
Management Cable and Transceiver Specifications and Pinouts on page 113
Copyright © 2018, Juniper Networks, Inc.
85
T4000 Core Router Hardware Guide
86 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 9
Planning and Preparing the Site
•
Overview of Preparing the Site for the T4000 Router on page 87
•
T4000 Router Environmental Specifications on page 88
•
General Site Guidelines on page 89
•
T4000 Chassis Grounding Cable and Lug Specifications on page 90
•
T4000 Clearance Requirements for Airflow and Hardware Maintenance on page 91
•
T4000 Router Physical Specifications on page 91
•
Site Electrical Wiring Guidelines on page 93
•
Rack Requirements for the T4000 Router on page 93
Overview of Preparing the Site for the T4000 Router
To prepare a site for router installation:
1.
Verify that environmental factors such as temperature and humidity do not exceed router tolerances.
See
“T4000 Router Environmental Specifications” on page 88 .
2.
Verify that the site and installation plan meets all safety guidelines and requirements.
See
“General Safety Guidelines and Warnings” on page 393 .
3.
Measure distance between external power sources and the router installation site.
See:
•
T4000 DC Power Distribution on page 104
•
T4000 DC Power Cable and Lugs Specifications on page 105
•
T4000 DC Power Requirements on page 97
•
T4000 DC Power Supply Specifications on page 102
•
T4000 DC Power System Electrical Specifications on page 101
4.
Locate sites for connection of system grounding.
See
“T4000 Chassis Grounding Cable and Lug Specifications” on page 90 .
Copyright © 2018, Juniper Networks, Inc.
87
T4000 Core Router Hardware Guide
5.
Calculate the power consumption and requirements.
See
“T4000 DC Power Requirements” on page 97
.
6.
Verify that the plan for power installation meets all electrical safety guidelines. See:
•
General Electrical Safety Guidelines and Warnings on page 421
•
T4000 DC Power Electrical Safety Guidelines on page 424
7.
Verify that your rack meets the minimum requirements for the installation of the router.
See
“Rack Requirements for the T4000 Router” on page 93 .
8.
Plan the location of the rack, including required space for airflow and maintenance.
See
“T4000 Clearance Requirements for Airflow and Hardware Maintenance” on page 91
.
9.
Plan to secure the rack to the floor and building structure.
See
“Rack Requirements for the T4000 Router” on page 93 .
10.
Acquire cables and connectors:
• Determine the number of cables needed based on your planned configuration.
• Review the maximum distance allowed for each cable. Choose the length of cable based on the distance between the hardware components being connected.
See the T4000 Core Router Interface Module Reference .
11.
Plan the cable routing and management.
See
“Maintaining T4000 PICs” on page 338 .
Related
Documentation
•
Overview of Installing the T4000 Router on page 119
T4000 Router Environmental Specifications
specifies the environmental specifications required for normal router operation. In addition, the site should be as dust-free as possible.
Table 61: Router Environmental Specifications
Description Value
Altitude No performance degradation to 10,000 ft (3048 m)
Relative humidity Normal operation ensured in relative humidity range of 5% to 90%, noncondensing
88 Copyright © 2018, Juniper Networks, Inc.
Chapter 9: Planning and Preparing the Site
Table 61: Router Environmental Specifications (continued)
Description Value
Temperature Normal operation ensured in temperature range of 32°F (0°C) to
104°F (40°C)
Nonoperating storage temperature in shipping : –40°F (–40°C) to
158°F (70°C)
Seismic Designed to meet Telcordia Technologies Zone 4 earthquake requirements
Maximum thermal output DC power: 33583.6 BTU/hour (9840 W W)
NOTE: Install the router only in restricted areas, such as dedicated equipment rooms and equipment closets, in accordance with Articles 110-16, 110-17, and
110-18 of the National Electrical Code, ANSI/NFPA 70.
Related
Documentation
•
Routine Maintenance Procedures for the T4000 Router on page 331
•
General Safety Guidelines and Warnings on page 393
•
Qualified Personnel Warning on page 396
•
Restricted Access Warning on page 402
General Site Guidelines
Efficient device operation requires proper site planning and maintenance and proper layout of the equipment, rack or cabinet (if used), and wiring closet.
To plan and create an acceptable operating environment for your device and prevent environmentally caused equipment failures:
• Keep the area around the chassis free from dust and conductive material, such as metal flakes.
• Follow prescribed airflow guidelines to ensure that the cooling system functions properly and that exhaust from other equipment does not blow into the intake vents of the device.
• Follow the prescribed electrostatic discharge (ESD) prevention procedures to prevent damaging the equipment. Static discharge can cause components to fail completely or intermittently over time.
• Install the device in a secure area, so that only authorized personnel can access the device.
Copyright © 2018, Juniper Networks, Inc.
89
T4000 Core Router Hardware Guide
Related
Documentation
•
Prevention of Electrostatic Discharge Damage on page 423
T4000 Chassis Grounding Cable and Lug Specifications
To meet safety and electromagnetic interference (EMI) requirements and to ensure proper operation, the router must be adequately grounded before power is connected.
Two pairs of threaded inserts (PEM nuts) are provided on the right rear of the chassis for connecting the router to earth ground. The left pair of grounding points fits M6 screws
(European), and the right pair fits UNC 1/4–20 screws (American). The grounding points are spaced at 0.625-in. (15.86-mm) centers.
You must supply a grounding cable.
summarizes the specifications for the grounding cable and lug.
Table 62: Grounding Cable Specifications
Cable specification 8-AWG (8.35 mm
2
), minimum 90°C wire, or as required by the local code.
Connector specification Cable lug; at 0.625-in. (15.86-mm) center line.
CAUTION: Before router installation begins, a licensed electrician must attach a cable lug to the grounding cable that you supply. A cable with an incorrectly attached lug can damage the router.
The accessory box shipped with the router includes one 4-AWG (21.2 mm
2 cable lug that attaches to the grounding cable and is used to secure the grounding cable to the grounding points (see
Figure 26 on page 90 ). (The cable lug shown in Figure 26 on page 90
is also used for the DC power cables.)
Figure 26: Grounding Cable Lug
Related
Documentation
•
Tools and Parts Required to Ground the T4000 Router on page 173
•
Connecting the T4000 Grounding Cable on page 174
90 Copyright © 2018, Juniper Networks, Inc.
Chapter 9: Planning and Preparing the Site
T4000 Clearance Requirements for Airflow and Hardware Maintenance
When planning the installation site, you need to allow sufficient clearance around the rack (see
):
• For the cooling system to function properly, the airflow around the chassis must be unrestricted.
NOTE: If you mount the router in a cabinet, be sure that ventilation is sufficient to prevent overheating.
• For service personnel to remove and install hardware components, there must be adequate space at the front and back of the router. At least 24 in. (61 cm) are required both in front of and behind the router. NEBS GR-63 recommends that you allow at least 30 in. (72.6 cm) behind the rack.
Figure 27: Chassis Dimensions and Clearance Requirements
30" (76.2 cm) clearance recommended for maintenance
31 "
(78.7 cm)
30" (76.2 cm) clearance recommended for maintenance
(without rear cable management system)
Front of chassis
19.2"
(48.7 cm)
17.4"
(44.2 cm)
Rear of chassis
Front-mounting flange
Center-mounting bracket
2.4"
(6.1 cm)
19.8" (50.3 cm) width with rear cable managment system
30" (76.2 cm) clearance recommended for maintenance
(with rear cable management system)
9.5"
(24.1 cm) depth for optional rear cable managment system
Related
Documentation
•
T4000 Cooling System Description on page 25
•
Rack Requirements for the T4000 Router on page 93
•
T4000 Router Physical Specifications on page 91
T4000 Router Physical Specifications
lists the router's physical specifications.
Copyright © 2018, Juniper Networks, Inc.
91
T4000 Core Router Hardware Guide
Table 63: Physical Specifications
Description Value
Chassis dimensions 37.45 in. (95.1 cm) high
17.43 in. (44.3 cm) wide
31 in. (78.7 cm) deep
Total depth (including front cable management system)
35.5 in. (90.2 cm)
11.5 in. (29.2 cm) from front of chassis to center-mounting brackets
Router weight
Control board weight
Routing Engine weight
Craft interface weight
FPC weight
CIP weight
Air filter weight
Power supply weight
SCG weight
SIB weight
SIB weight for SIB-TXP-3D-LCC
Front fan tray weight
Rear fan tray weight
Rear fan tray weight for
FAN-R-TXP-3D-LCC
Chassis with midplane: 205 lb (93 kg)
Minimum configuration: 392 lb (177.8 kg)
Maximum configuration: 663.6 lb (301.0 kg)
5 lb each (2 kg)
2.4 lb (1 kg)
3.3 lb (1.5 kg)
FPC4 with PICs installed: Up to 33 lb (15.0 kg)
FPC4 without PICs installed: up to 29 lb (11.3 kg)
FPC5 with PICs installed: Up to 33.5 lb (15.2 kg)
FPC5 without PICs installed: 31.6 lb (14.4 kg)
Blank panel in FPC slot: 9 lb (4.0 kg)
8.8 lb (4 kg)
1 lb (0.45 kg)
39.7 lb (18.0 kg)
1.9 lb each (1 kg)
7.1 lb (3.2 kg)
9.4 lb (4.2 kg)
20.4 lb (9.3 kg)
10 lb (4.5 kg)
13 lb (5.9 kg)
92 Copyright © 2018, Juniper Networks, Inc.
Chapter 9: Planning and Preparing the Site
Related
Documentation
•
T4000 Router Description on page 3
•
T4000 Chassis Description on page 11
•
T4000 Installation Safety Guidelines on page 120
Site Electrical Wiring Guidelines
describes the factors you must consider while planning the electrical wiring at your site.
WARNING: It is particularly important to provide a properly grounded and shielded environment and to use electrical surge-suppression devices.
Table 64: Site Electrical Wiring Guidelines
Site Wiring Factor Guidelines
Signaling limitations
Radio frequency interference
Electromagnetic compatibility
If your site experiences any of the following problems, consult experts in electrical surge suppression and shielding:
•
•
•
Improperly installed wires cause radio frequency interference (RFI).
Damage from lightning strikes occurs when wires exceed recommended distances or pass between buildings.
Electromagnetic pulses (EMPs) caused by lightning damage unshielded conductors and electronic devices.
To reduce or eliminate RFI from your site wiring, do the following:
•
•
Use a twisted-pair cable with a good distribution of grounding conductors.
If you must exceed the recommended distances, use a high-quality twisted-pair cable with one ground conductor for each data signal when applicable.
If your site is susceptible to problems with electromagnetic compatibility (EMC), particularly from lightning or radio transmitters, seek expert advice.
Some of the problems caused by strong sources of electromagnetic interference (EMI) are:
•
•
Destruction of the signal drivers and receivers in the device
Electrical hazards as a result of power surges conducted over the lines into the equipment
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
•
General Electrical Safety Guidelines and Warnings on page 421
Rack Requirements for the T4000 Router
The router can be installed in many types of racks, including four-post (telco) racks and open-frame racks. An example of an open-frame rack is shown in
.
Copyright © 2018, Juniper Networks, Inc.
93
T4000 Core Router Hardware Guide
For open-frame racks, center-mounting is preferable to front-mounting because the more even distribution of weight provides greater stability.
The router is designed for installation in a 19-in. rack as defined in Cabinets, Racks, Panels, and Associated Equipment (document number EIA-310-D) published by the Electronics
Components Industry Association ( http://www.ecianow.org/ ).
With the use of adapters, the router can fit into a 600-mm-wide rack, as defined in the four-part Equipment Engineering (EE); European Telecommunications Standard for
Equipment Practice (document numbers ETS 300 119-1 through 119-4) published by the
European Telecommunications Standards Institute ( http://www.etsi.org
). Use approved wing devices to narrow the opening between the rails.
The rack rails must be spaced widely enough to accommodate the router chassis's external dimensions: 37.45 in. (95.1 cm) high, 31 in. (78.7 cm) deep, and 17.43 in. (44.3 cm) wide, excluding the front and rear cable management systems. The outer edges of the mounting brackets extend the width to 19 in. (48.3 cm). The spacing of rails and adjacent racks must also allow for the clearances around the router and rack.
The mounting holes for connecting the mounting brackets to the chassis are spaced
0.984 in. (25 mm) apart.
The chassis height of 37.45 in. (95.1 cm) is approximately 21.4 U. A U is the standard rack unit defined in Cabinets, Racks, Panels, and Associated Equipment (document number
EIA-310-D) published by the Electronics Industry Association. You can stack two routers in a rack that has at least 42.8 U (74.9 in. or 1.90 m) of usable vertical space.
The rack must be strong enough to support the weight of the fully configured router, up to 606 lb (275 kg). If you stack two fully configured routers in one rack, it must be capable of supporting about 1212 lb (550 kg).
94 Copyright © 2018, Juniper Networks, Inc.
Figure 28: Typical Open-Frame Rack
Chapter 9: Planning and Preparing the Site
Always secure the rack to the structure of the building. If your geographical area is subject to earthquakes, bolt the rack to the floor. For maximum stability, also secure the rack to ceiling brackets.
Related
Documentation
•
T4000 Router Physical Specifications on page 91
•
T4000 Clearance Requirements for Airflow and Hardware Maintenance on page 91
Copyright © 2018, Juniper Networks, Inc.
95
T4000 Core Router Hardware Guide
96 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 10
Calculating System Power Requirements
•
T4000 DC Power Requirements on page 97
T4000 DC Power Requirements
To allow for future growth so that you can operate the router in any hardware configuration without upgrading the power infrastructure, we recommend that you provision 56 A @
–48 VDC per input for the 60-A DC power cables connected to each power supply.
lists the power requirements for various hardware components when the router is operating under typical voltage conditions.
You can use the information in
and the PIC requirements in T4000
Core Router Interface Module Reference to calculate power consumption for various hardware configurations, input current from a different source voltage, and thermal output, as shown in the following examples for a DC-powered router.
Table 65: Typical DC Power Requirements for T4000 Components
Component
Current
Requirement
(Amps @
–48 VDC)
Base system, not including FPCs and PICs (includes five SIB-I-T4000 SIBs, one host subsystem, one SCG, cooling system at normal speed, and craft interface) and two power supplies
30.8 A
Base system, not including FPCs and PICs (includes five TXP-LCC-3D SIBs, one host subsystem, one SCG, cooling system with FAN-R-TXP-3D-LCC rear fan tray at normal speed, and craft interface) and two power supplies
31.0 A
SIB-I-T4000 SIB 4.7 A
TXP-LCC-3D SIB
T1600 Enhanced Scaling FPC4
T4000 FPC5
Line-card chassis control board (LCC-CB)
4.2 A
11.3 A
13.6 A
1.0 A
Copyright © 2018, Juniper Networks, Inc.
97
T4000 Core Router Hardware Guide
98
Table 65: Typical DC Power Requirements for T4000 Components (continued)
Component
Current
Requirement
(Amps @
–48 VDC)
C1800 Routing Engine
SCG
1.7 A
0.2 A
Redundant backup six-input DC power supply
Cooling system with FAN-REAR-TXP-LCC (normal speed)
Cooling system with FAN-REAR-TXP-LCC (full speed)
Cooling system with FAN-R-TXP-3D-LCC rear fan tray (normal speed)
Cooling system with FAN-R-TXP-3D-LCC rear fan tray (full speed)
Craft interface
PIC—Generalized typical value
PIC—Generalized maximum value
5.2 A
8.2 A
23.6 A
9.5 A
26.7 A
0.2 A
0.625 A
3.3 A
• Example of calculating power consumption for a minimum configuration:
Base System + 1 Type 4 FPC + 1 PIC
30.8 A + 11.3 A + 0.625 A = 42.7 A @ –48 VDC = 2050 W
• Example of calculating power consumption for a maximum configuration with eight
FPCs:
Base System + 1 LCC-CB + 1 RE-C1800 + 1 SCG + 8 T1600-Type 4 FPCs + 16 PICs +
(cooling system full speed - normal speed)
30.8 A + 1.0 A + 1.7 A + 0.2 A + 8 (11.3 A) + 16 (3.3 A) + (23.6 A - 8.2 A)
30.8 A + 1.0 A + 1.7 A + 0.2 A + A + 90.4 A + 52.8 A + 15.4 A = 192.3 A @ –48 VDC = 9230
W
• Current requirement adjustment for fans running at full speed (high temperature environment or cooling component failure):
Calculated system current (X) – Cooling (normal) + Cooling (full speed) =
X A – 6.7 A + 22 A = X A + 15.3 A
• Input current from a DC source other than –48 VDC (based on maximum configuration):
(–54 VDC input) x (input current X) = (–48 VDC) x (input current Y)
54 x X = 48 x 94.1 A
X = 48 x 94.1 A/54 = 83.6 A
• Example of calculating typical system thermal output for a configuration:
Watts DC/0.293 = BTU/hr
Copyright © 2018, Juniper Networks, Inc.
Chapter 10: Calculating System Power Requirements
9230 W/0.293 = 31,501 BTU/hr
Related
Documentation
•
T4000 DC Power System Electrical Specifications on page 101
•
Overview of Preparing the Site for the T4000 Router on page 87
•
T4000 DC Power Distribution on page 104
•
T4000 Power System Description on page 75
Copyright © 2018, Juniper Networks, Inc.
99
T4000 Core Router Hardware Guide
100 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 11
DC Power Specifications A
•
T4000 DC Power System Electrical Specifications on page 101
•
T4000 DC Power Supply Specifications on page 102
•
T4000 Power Management (Four 60-A Cables on a Six-Input DC Power
•
T4000 Power Management (Three 80-A Cables on a Six-Input DC Power
•
T4000 DC Power Distribution on page 104
•
T4000 DC Power Cable and Lugs Specifications on page 105
T4000 DC Power System Electrical Specifications
lists the DC power system electrical specifications.
Table 66: DC Power System Electrical Specifications
Item Specification
DC input voltage
DC system current rating
Operating range: –40.0 to –72.0 VDC
205 A @ –48 VDC (nominal) (9840 W)
Input 0: 25 A @ –48 VDC (nominal) (1200 W)
Input 1 through 5: 180 A @ -–48 VDC (nominal)
(8640 W)
For each power supply, we recommend that you provision at least 56 A @ –48 VDC per input. Doing so enables you to operate the router in any configuration without upgrading the power infrastructure. Although Input 0 in the DC power supply requires less power, we recommend provisioning the same amount of power for each input to avoid the possibility of connecting the lower-powered DC cable to Input 1 through Input 5.
Circuit breaker current rating of 100 A per feed maximum shall be incorporated external to the equipment. The voltage rating of this breaker shall be 80 V minimum. For each power supply input, use a facility circuit breaker rated for 100 A (–48 VDC) maximum or as required by local code. You must provision a circuit breaker for each DC power supply input rated for at least 125% of the continuous current that the system draws at –48 VDC.
Copyright © 2018, Juniper Networks, Inc.
101
T4000 Core Router Hardware Guide
Related
Documentation
•
T4000 Power System Description on page 75
•
T4000 DC Power Supply Specifications on page 102
•
T4000 DC Power Requirements on page 97
•
T4000 DC Power Cable and Lugs Specifications on page 105
•
T4000 DC Power Distribution on page 104
T4000 DC Power Supply Specifications
lists the DC power supply electrical specifications.
Table 67: Power Supply Electrical Specifications
Item Specification
DC input voltage
Input DC current rating (per input)
Nominal –48 VDC, –60 VDC
Operating range: –40.0 to –72.0 VDC
NOTE: If the input voltage from the DC power source drops below -37.5 to -39.5 VDC, the router automatically shuts down. During automatic shutdown, the circuit remains active.
When the input voltage returns to –43.0 to
–44.00 VDC, the router automatically starts up again and the system returns to normal operation within 30 minutes. No operator intervention is required.
Input 0: 45 A @ –48 VDC (nominal) (2160 W)
(54 A @ –40 VDC)
Input 1: 56 A @ –48 VDC (nominal) (2688 W)
(67.2 A @ –40 VDC)
Input 2: 56 A @ –48 VDC (nominal) (2688 W)
(67.2 A @ –40 VDC)
Input 3: 56 A @ –48 VDC (nominal) (2688 W)
(67.2 A @ –40 VDC)
Input 4: 56 A @ –48 VDC (nominal) (2688 W)
(67.2 A @ –40 VDC)
Input 5: 56 A @ –48 VDC (nominal) (2688 W)
(67.2 A @ –40 VDC)
Related
Documentation
•
T4000 Power System Description on page 75
•
T4000 DC Power Requirements on page 97
•
T4000 DC Power Cable and Lugs Specifications on page 105
•
T4000 DC Power Distribution on page 104
102 Copyright © 2018, Juniper Networks, Inc.
Chapter 11: DC Power Specifications A
T4000 Power Management (Four 60-A Cables on a Six-Input DC Power Supply)
For Junos OS Release 12.3 and later, the power management feature ensures that the router has enough power to support an FPC before the FPC is brought online. To configure the power management feature, see
loaded chassis when you connect four 60-A DC power cables to a six 60-A input power supply.
If the power is underprovisioned for your hardware configuration, power management limits the number of FPCs brought online based on the following rules:
• When a T1600 Enhanced Scaling FPC4 (Model: T1600-FPC4-ES) is installed, the maximum number of FPCs that can be online is six.
• When there are no T1600-FPC4-ES installed, the maximum number of FPCs that can be online is seven.
For example, if there are six online FPCs and you insert a T1600-FPC4-ES, the power management feature will not power on the FPC.
NOTE: In the event of a chassis restart, master switchover, or router reboot, the power management feature powers on the FPCs based on the setting of the set chassis fru-poweron-sequence command.
CAUTION: If you do not configure the power management feature and you are connecting four 60-A DC power cables to the six-input power supply and the maximum power draw is exceeded, FRU states might change from Online to Offline or Present, or the interfaces might flap, or some traffic might drop.
Related
Documentation
•
Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 194
•
Configuring DC Power on a T4000 Router on page 213
• T4000 Power Management Overview
T4000 Power Management (Three 80-A Cables on a Six-Input DC Power Supply)
For Junos OS Release 12.3 and later, the power management feature ensures that the router has enough power to support an FPC before the FPC is brought online. To configure the power management feature, see
loaded chassis when you connect three 80-A DC power cables to a six 60-A input power supply using terminal jumpers.
Copyright © 2018, Juniper Networks, Inc.
103
T4000 Core Router Hardware Guide
If the power is underprovisioned for your hardware configuration, power management limits the number of FPCs brought online based on the following rules:
• A maximum of six T1600 Enhanced Scaling FPC4 (Model: T1600-FPC4-ES) can be online.
• When one T1600-FPC4-ES is installed, a maximum of seven FPCs can be online.
• When there are no T1600-FPC4-ES installed, a maximum of eight FPCs (a fully loaded chassis) can be online.
For example, if there are seven online FPCs and you insert an T1600-FPC4-ES, the power management feature will not power on the FPC.
NOTE: In the event of a chassis restart, master switchover, or router reboot, the power management feature powers on the FPCs based on the setting of the set chassis fru-poweron-sequence command.
CAUTION: If you do not configure the power management feature and you are connecting three 80-A DC power cables to the six-input power supply and the maximum power draw is exceeded, FRU states might change from
Online to Offline or Present, or the interfaces might flap, or some traffic might drop.
Related
Documentation
•
Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A
•
Configuring DC Power on a T4000 Router on page 213
• T4000 Power Management Overview
T4000 DC Power Distribution
Most sites distribute DC power through a main conduit that leads to frame-mounted DC power distribution panels, one of which might be located at the top of the rack that houses the router. A pair of cables (one input and one return) connects each set of terminal studs to the power distribution panel.
NOTE: All inputs on the DC power supply in slot 0 must be powered by dedicated power feeds derived from feed A, and all inputs on the DC power supply in slot 1 must be powered by dedicated power feeds derived from feed
B. This configuration provides the commonly deployed A/B feed redundancy for the system.
shows a typical DC source cabling arrangement.
104 Copyright © 2018, Juniper Networks, Inc.
Chapter 11: DC Power Specifications A
Figure 29: Typical DC Source Cabling to the Router
PEM 0
Feed A
PEM 1
Central office
Primary & secondary
DC power distribution
Ground window
Central office ground
Rectifiers
Plant controls
Batteries
Battery plant
Feed B
AC
Central office
Primary & secondary
DC power distribution
Rectifiers
AC
Ground window
CO ground
Central office ground
Plant controls
Batteries
Battery plant Return (+)
Input (–)
Central office ground
Chassis grounding points
Related
Documentation
•
T4000 Power System Description on page 75
•
Connecting DC Power to the T4000 Router (Six 60-A Inputs) on page 186
•
Connecting DC Power to the T4000 Router (Five 60-A Inputs) on page 190
•
Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 194
•
Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A
•
Replacing a T4000 Six-Input DC Power Supply on page 307
•
T4000 DC Power Electrical Safety Guidelines on page 424
T4000 DC Power Cable and Lugs Specifications
•
•
DC Power Cables
You must supply DC power cables that meet the following specifications: 4-AWG
(21.2 mm
2
), minimum 90°C wire, or as required by the local code.
summarizes the number of DC power cables required, which you must supply.
Copyright © 2018, Juniper Networks, Inc.
105
T4000 Core Router Hardware Guide
Table 68: DC Power Cables Required
Number of Inputs Connected Power Cables Required
5
6
10
12
WARNING: For field-wiring connections, use copper conductors only.
WARNING: DC Power cables must not block access to router components or drape where people could trip on them.
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
DC Power Lugs
The accessory box shipped with the router includes cable lugs for 4-AWG (21.2 mm
2
) cable lugs. The cable lugs are dual hole, and sized to fit 1/4-20 UNC terminal studs at
15.86-mm (0.625-in.) center line.
Figure 30: DC Power Cable Lug
106
The cable lug shown in
is also used for the grounding the chassis.
CAUTION: Before router installation begins, a licensed electrician must attach a cable lug to the power cables that you supply. A cable with an incorrectly attached lug can damage the router.
Related
Documentation
•
T4000 Power System Description on page 75
Copyright © 2018, Juniper Networks, Inc.
Chapter 11: DC Power Specifications A
•
Connecting DC Power to the T4000 Router (Six 60-A Inputs) on page 186
•
Connecting DC Power to the T4000 Router (Five 60-A Inputs) on page 190
•
Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 194
•
Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A
•
Replacing a T4000 Six-Input DC Power Supply on page 307
•
T4000 DC Power Electrical Safety Guidelines on page 424
Copyright © 2018, Juniper Networks, Inc.
107
T4000 Core Router Hardware Guide
108 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 12
Network Cable and Transceiver Planning
•
Understanding Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion on page 109
•
Calculating Power Budget and Power Margin for Fiber-Optic Cables on page 110
Understanding Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion
This topic describes signal loss, attenuation, and dispersion in fiber-optic cable.
•
Signal Loss in Multimode and Single-Mode Fiber-Optic Cable on page 109
•
Attenuation and Dispersion in Fiber-Optic Cable on page 109
Signal Loss in Multimode and Single-Mode Fiber-Optic Cable
Multimode fiber is large enough in diameter to allow rays of light to reflect internally
(bounce off the walls of the fiber). Interfaces with multimode optics typically use LEDs as light sources. However, LEDs are not coherent sources. They spray varying wavelengths of light into the multimode fiber, which reflects the light at different angles. Light rays travel in jagged lines through a multimode fiber, causing signal dispersion. When light traveling in the fiber core radiates into the fiber cladding, higher-order mode loss results.
Together these factors limit the transmission distance of multimode fiber compared with single-mode fiber.
Single-mode fiber is so small in diameter that rays of light can reflect internally through one layer only. Interfaces with single-mode optics use lasers as light sources. Lasers generate a single wavelength of light, which travels in a straight line through the single-mode fiber. Compared with multimode fiber, single-mode fiber has higher bandwidth and can carry signals for longer distances.
Exceeding the maximum transmission distances can result in significant signal loss, which causes unreliable transmission.
Attenuation and Dispersion in Fiber-Optic Cable
Correct functioning of an optical data link depends on modulated light reaching the receiver with enough power to be demodulated correctly.
Attenuation is the reduction in power of the light signal as it is transmitted. Attenuation is caused by passive media components, such as cables, cable splices, and connectors. Although attenuation is significantly lower for optical fiber than for other media, it still occurs in both multimode
Copyright © 2018, Juniper Networks, Inc.
109
T4000 Core Router Hardware Guide and single-mode transmission. An efficient optical data link must have enough light available to overcome attenuation.
Dispersion is the spreading of the signal over time. The following two types of dispersion can affect an optical data link:
• Chromatic dispersion—Spreading of the signal over time resulting from the different speeds of light rays.
• Modal dispersion—Spreading of the signal over time resulting from the different propagation modes in the fiber.
For multimode transmission, modal dispersion, rather than chromatic dispersion or attenuation, usually limits the maximum bit rate and link length. For single-mode transmission, modal dispersion is not a factor. However, at higher bit rates and over longer distances, chromatic dispersion rather than modal dispersion limits maximum link length.
An efficient optical data link must have enough light to exceed the minimum power that the receiver requires to operate within its specifications. In addition, the total dispersion must be less than the limits specified for the type of link in Telcordia Technologies document GR-253-CORE (Section 4.3) and International Telecommunications Union
(ITU) document G.957.
When chromatic dispersion is at the maximum allowed, its effect can be considered as a power penalty in the power budget. The optical power budget must allow for the sum of component attenuation, power penalties (including those from dispersion), and a safety margin for unexpected losses.
Calculating Power Budget and Power Margin for Fiber-Optic Cables
Use the information in this topic and the specifications for your optical interface to calculate the power budget and power margin for fiber-optic cables.
TIP: You can use the Hardware Compatibility Tool to find information about the pluggable transceivers supported on your Juniper Networks device.
To calculate the power budget and power margin, perform the following tasks:
1.
Calculating Power Budget for Fiber-Optic Cable on page 110
2.
Calculating Power Margin for Fiber-Optic Cable on page 111
Calculating Power Budget for Fiber-Optic Cable
To ensure that fiber-optic connections have sufficient power for correct operation, you need to calculate the link's power budget, which is the maximum amount of power it can transmit. When you calculate the power budget, you use a worst-case analysis to provide a margin of error, even though all the parts of an actual system do not operate at the worst-case levels. To calculate the worst-case estimate of power budget (P
B you assume minimum transmitter power (P
T
) and minimum receiver sensitivity (P
R
),
):
110 Copyright © 2018, Juniper Networks, Inc.
Chapter 12: Network Cable and Transceiver Planning
P
B
= P
T
– P
R
The following hypothetical power budget equation uses values measured in decibels
(dB) and decibels referred to one milliwatt (dBm):
P
B
= P
T
– P
R
P
B
= –15 dBm – (–28 dBm)
P
B
= 13 dB
Calculating Power Margin for Fiber-Optic Cable
After calculating a link's power budget, you can calculate the power margin (P
M
), which represents the amount of power available after subtracting attenuation or link loss (LL) from the power budget (P
B
). A worst-case estimate of P
M assumes maximum LL:
P
M
= P
B
– LL
P
M greater than zero indicates that the power budget is sufficient to operate the receiver.
Factors that can cause link loss include higher-order mode losses, modal and chromatic dispersion, connectors, splices, and fiber attenuation.
lists an estimated amount of loss for the factors used in the following sample calculations. For information about the actual amount of signal loss caused by equipment and other factors, refer to vendor documentation.
Table 69: Estimated Values for Factors Causing Link Loss
Link-Loss Factor Estimated Link-Loss Value
Higher-order mode losses Single-mode—None
Multimode—0.5 dB
Modal and chromatic dispersion
Connector
Splice
Fiber attenuation
Single-mode—None
Multimode—None, if product of bandwidth and distance is less than 500
MHz-km
0.5 dB
0.5 dB
Single-mode—0.5 dB/km
Multimode—1 dB/km
The following sample calculation for a 2-km-long multimode link with a power budget
(P
B
) of 13 dB uses the estimated values from
to calculate link loss
(LL) as the sum of fiber attenuation (2 km @ 1 dB/km, or 2 dB) and loss for five connectors
(0.5 dB per connector, or 2.5 dB) and two splices (0.5 dB per splice, or 1 dB) as well as higher-order mode losses (0.5 dB). The power margin (P
M
) is calculated as follows:
Copyright © 2018, Juniper Networks, Inc.
111
T4000 Core Router Hardware Guide
P
M
= P
B
– LL
P
M
= 13 dB – 2 km (1 dB/km) – 5 (0.5 dB) – 2 (0.5 dB) – 0.5 dB
P
M
= 13 dB – 2 dB – 2.5 dB – 1 dB – 0.5 dB
P
M
= 7 dB
The following sample calculation for an 8-km-long single-mode link with a power budget
(P
B
) of 13 dB uses the estimated values from
to calculate link loss
(LL) as the sum of fiber attenuation (8 km @ 0.5 dB/km, or 4 dB) and loss for seven connectors (0.5 dB per connector, or 3.5 dB). The power margin (P
M follows:
) is calculated as
P
M
= P
B
– LL
P
M
= 13 dB – 8 km (0.5 dB/km) – 7(0.5 dB)
P
M
= 13 dB – 4 dB – 3.5 dB
P
M
= 5.5 dB
In both examples, the calculated power margin is greater than zero, indicating that the link has sufficient power for transmission and does not exceed the maximum receiver input power.
112 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 13
Management Cable and Transceiver
Specifications and Pinouts
•
T4000 Routing Engine Interface Cable Specifications on page 113
•
T4000 Alarm Relay Contact Wire Specifications on page 114
•
DB-9 Connector Pinouts for the Routing Engine AUXILIARY and CONSOLE
•
RJ-45 Connector Pinouts for the T4000 Management ETHERNET Port on page 115
T4000 Routing Engine Interface Cable Specifications
lists the specifications for the cables that connect to the management ports on the connector interface panel (CIP).
Table 70: Cable Specifications for Routing Engine Management
Port Cable Specification Cable/Wire Supplied
Maximum
Length
Router
Receptacle
6 ft (1.83 m) DB-9 male Routing Engine console or auxiliary interface
Routing Engine
Ethernet interface
RS-232 (EIA-232) serial cable
One 6-ft (1.83-m) length with
DB-9/DB-9 connectors
Category 5 cable or equivalent suitable for 100Base-T operation
One 15-ft (4.57-m) length with
RJ-45/RJ-45 connectors
328 ft
(100 m)
RJ-45 autosensing
Related
Documentation
•
T4000 Connector Interface Panel (CIP) Description on page 14
•
Connecting the T4000 Router to a Management Ethernet Device on page 180
•
Connecting the T4000 Router to a Management Console or Auxiliary Device on page 178
•
DB-9 Connector Pinouts for the Routing Engine AUXILIARY and CONSOLE Ports on page 114
•
RJ-45 Connector Pinouts for the T4000 Management ETHERNET Port on page 115
Copyright © 2018, Juniper Networks, Inc.
113
T4000 Core Router Hardware Guide
T4000 Alarm Relay Contact Wire Specifications
For management and service operations, you can connect the router to external alarm-reporting devices through the alarm relay contacts on the CIP. You must provide a wire with gauge between 28-AWG and 14-AWG (0.08 and 2.08 mm
2
).
Related
Documentation
•
T4000 Connector Interface Panel (CIP) Description on page 14
•
Connecting the T4000 Router to an External Alarm-Reporting Device on page 182
DB-9 Connector Pinouts for the Routing Engine AUXILIARY and CONSOLE Ports
3
4
1
2
5
The ports on the CIP labeled AUXILIARY and CONSOLE are DB-9 receptacles that accept
RS-232 (EIA-232) cable. The AUXILIARY port connects the Routing Engine to a laptop, modem, or other auxiliary unit, and the CONSOLE port connects it to a management console. The ports are configured as data terminal equipment (DTE).
describes the DB-9 connector pinouts.
Table 71: DB-9 Connector Pinouts
Pin Signal Direction Description
DCD
RxD
TxD
DTR
Ground
<–
<–
–>
–>
—
Carrier Detect
Receive Data
Transmit Data
Data Terminal Ready
Signal Ground
8
9
6
7
DSR
RTS
CTS
RING
<–
–>
<–
<–
Data Set Ready
Request To Send
Clear To Send
Ring Indicator
Related
Documentation
•
T4000 Connector Interface Panel (CIP) Description on page 14
•
T4000 Routing Engine Interface Cable Specifications on page 113
•
Connecting the T4000 Router to a Management Console or Auxiliary Device on page 178
114 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: Management Cable and Transceiver Specifications and Pinouts
RJ-45 Connector Pinouts for the T4000 Management ETHERNET Port
3
4
1
2
5
The port on the CIP labeled ETHERNET is an autosensing 10/100-Mbps Ethernet Ethernet
RJ-45 receptacle that accepts an Ethernet cable for connecting the Routing Engine to a management LAN (or other device that supports out-of-band management).
describes the RJ-45 connector pinouts.
Table 72: RJ-45 Connector Pinouts
Pin Signal
TX+
TX –
RX+
Termination network
Termination network
6
7
8
RX–
Termination network
Termination network
Related
Documentation
•
T4000 Connector Interface Panel (CIP) Description on page 14
•
Connecting the T4000 Router to a Management Ethernet Device on page 180
•
T4000 Routing Engine Interface Cable Specifications on page 113
Copyright © 2018, Juniper Networks, Inc.
115
T4000 Core Router Hardware Guide
116 Copyright © 2018, Juniper Networks, Inc.
PART 3
Initial Installation and Configuration
•
Installation Overview on page 119
•
Unpacking the Router on page 123
•
Installing the Mounting Hardware on page 129
•
Overview of Installing the Router into a Rack on page 137
•
Installing the Router into a Rack With a Mechanical Lift on page 139
•
Installing the Router into a Rack Without a Mechanical Lift on page 147
•
Connecting the Router to Ground on page 173
•
Connecting the Router to External Devices on page 177
•
Connecting the Router to Power on page 185
•
Powering On the Router on page 207
•
Configuring the JUNOS Software on page 209
•
Upgrading to a T4000 Router From a T640 or T1600 Router on page 217
Copyright © 2018, Juniper Networks, Inc.
117
T4000 Core Router Hardware Guide
118 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 14
Installation Overview
•
Overview of Installing the T4000 Router on page 119
•
T4000 Installation Safety Guidelines on page 120
Overview of Installing the T4000 Router
You must proceed through the installation process in the following order:
1.
Review all safety guidelines and warnings for the router.
WARNING: To avoid harm to yourself or the router as you install and maintain it, you must follow the safety procedures for working with Internet routers, as well as the guidelines and warnings for working with and near electrical equipment. However, providing an exhaustive set of guidelines for working with electrical equipment is beyond the scope of this documentation.
See
“General Safety Guidelines and Warnings” on page 393 .
2.
Prepare the installation site for the router.
See
“Overview of Preparing the Site for the T4000 Router” on page 87 .
3.
Unpack the router and verify the parts received.
See
“Overview of Unpacking the T4000 Router” on page 123
.
4.
Install the mounting hardware. See:
•
“Installing the T4000 Mounting Hardware for a Four-Post Rack or Cabinet” on page 129
.
•
“Installing the T4000 Mounting Hardware for an Open-Frame Rack” on page 133
.
5.
Install the router into the rack. See:
•
Overview of Installing the T4000 Router into a Rack on page 137
•
Overview of Installing a T4000 Router Using a Mechanical Lift on page 139
Copyright © 2018, Juniper Networks, Inc.
119
T4000 Core Router Hardware Guide
•
Overview of Installing a T4000 Router Without a Mechanical Lift on page 147
6.
Ground the router.
See
“Connecting the T4000 Grounding Cable” on page 174
.
7.
Connect the router to external devices. See:
•
Overview of Connecting the T4000 Router to External Devices on page 177
•
Connecting the T4000 Router to a Management Console or Auxiliary Device on page 178
•
Connecting the T4000 Router to an External Alarm-Reporting Device on page 182
• Connecting the T4000 Router to an External Clocking Device
•
Connecting PIC Cables to the T4000 Router on page 183
•
Connecting the T4000 Router to a Management Ethernet Device on page 180
8.
Connect the power. See:
•
Connecting DC Power to the T4000 Router (Six 60-A Inputs) on page 186
•
Connecting DC Power to the T4000 Router (Five 60-A Inputs) on page 190
•
Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 194
•
Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six
9.
Power on the router.
See
“Powering On the T4000 Router” on page 207
.
Related
Documentation
•
T4000 Router Description on page 3
T4000 Installation Safety Guidelines
Observe the following guidelines before and during router installation:
•
General Installation Safety Guidelines on page 120
•
Chassis Lifting Guidelines on page 121
General Installation Safety Guidelines
Before installing or moving the router, verify that the intended site meets the specified power, environmental, and clearance requirements. See the following documentation:
•
T4000 Clearance Requirements for Airflow and Hardware Maintenance on page 91
•
Rack Requirements for the T4000 Router on page 93
•
T4000 Router Environmental Specifications on page 88
•
T4000 DC Power Requirements on page 97
120 Copyright © 2018, Juniper Networks, Inc.
Chapter 14: Installation Overview
Chassis Lifting Guidelines
The weight of a fully configured router is about 663.6 lb (301.0 kg). Observe the following guidelines for lifting and moving the router:
• Do not attempt to lift a fully configured router by yourself. Using a mechanical lift to maneuver the router into a rack is recommended. If a lift cannot be used, a minimum of 4 people are required to lift the router, and you must remove components from the chassis before lifting.
• Before lifting or moving the router, disconnect all external cables.
• As when lifting any heavy object, lift most of the weight with your legs rather than your back. Keep your knees bent and your back relatively straight and avoid twisting your body as you lift. Balance the load evenly and be sure that your footing is solid.
Related
Documentation
•
Overview of Preparing the Site for the T4000 Router on page 87
Copyright © 2018, Juniper Networks, Inc.
121
T4000 Core Router Hardware Guide
122 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 15
Unpacking the Router
•
Overview of Unpacking the T4000 Router on page 123
•
Tools and Parts Required to Unpack the T4000 Router on page 123
•
Unpacking the T4000 Router on page 124
•
Verifying the T4000 Router Parts Received on page 125
Overview of Unpacking the T4000 Router
To unpack the router:
1.
Gather the tools required to unpack the router.
See
“Tools and Parts Required to Unpack the T4000 Router” on page 123 .
2.
Remove the router, accessory box, tool kit, and all parts from the shipping crate.
See
“Unpacking the T4000 Router” on page 124
3.
Verify that all parts have been received.
See
“Verifying the T4000 Router Parts Received” on page 125 .
Related
Documentation
•
Overview of Installing the T4000 Router on page 119
Tools and Parts Required to Unpack the T4000 Router
To unpack the router and prepare for installation, you need the following tools:
• Phillips (+) screwdriver, number 2
• 1/2-in. or 13-mm open-end or socket wrench to remove bracket bolts from the shipping pallet
• Blank panels to cover any slots not occupied by a component
Related
Documentation
•
Overview of Unpacking the T4000 Router on page 123
Copyright © 2018, Juniper Networks, Inc.
123
T4000 Core Router Hardware Guide
•
Unpacking the T4000 Router on page 124
•
Verifying the T4000 Router Parts Received on page 125
Unpacking the T4000 Router
The router is shipped in a wooden crate. A wooden pallet forms the base of the crate.
The router chassis is bolted to this pallet. Quick Start installation instructions and a cardboard accessory box are also included in the shipping crate.
The shipping crate measures:
• 51 in. (129 cm) high
• 35 in. (89 cm) wide
• 43 in. (110 cm) deep
The total weight of the crate containing the router and accessories can range up to 392 lb
(178 kg).
NOTE: The router is maximally protected inside the shipping crate. Do not unpack it until you are ready to begin installation.
To unpack the router (see
):
1.
Move the shipping crate to a staging area as close to the installation site as possible, where you have enough room to remove the components from the chassis. While the chassis is bolted to the pallet, you can use a forklift or pallet jack to move it.
2.
Position the shipping crate with the arrows pointing up.
3.
Open all the latches on the shipping crate.
4.
Remove the front door of the shipping crate cover and set it aside.
5.
Slide the remainder of the shipping crate cover off the pallet.
6.
Remove the foam covering the top of the router.
7.
Remove the accessory box and the Quick Start documentation.
8.
Verify the parts received against the lists in
“Verifying the T4000 Router Parts
124 Copyright © 2018, Juniper Networks, Inc.
Chapter 15: Unpacking the Router
9.
Remove the vapor corrosion inhibitor (VCI) packs attached to the pallet, being careful not to break the VCI packs open.
10.
To remove the brackets holding the chassis on the pallet, use a 1/2-in. socket wrench and a number 2 Phillips screwdriver to remove the bolts and screws from the brackets.
11.
Store the brackets and bolts inside the accessory box.
12.
Save the shipping crate cover, pallet, and packing materials in case you need to move or ship the router at a later time.
Figure 31: Contents of the Shipping Crate
Related
Documentation
•
Overview of Unpacking the T4000 Router on page 123
•
Tools and Parts Required to Unpack the T4000 Router on page 123
•
Verifying the T4000 Router Parts Received on page 125
Verifying the T4000 Router Parts Received
A packing list is included in each shipment. Check the parts in the shipment against the items on the packing list. The packing list specifies the part numbers and descriptions of each part in your order.
If any part is missing, contact a customer service representative.
Copyright © 2018, Juniper Networks, Inc.
125
T4000 Core Router Hardware Guide
The main shipment contains the router chassis with installed components, listed in
Table 73 on page 126 , and an accessory box, which contains the parts listed in
Table 73: Router Parts List
Component Quantity
Chassis, including midplane, craft interface
FPCs
PICs
SIBs
Routing Engines
1
Up to 8
Up to 4 per FPC
5
1 or 2
Control boards
SCGs
Power supplies
CIP
Front fan trays
Rear fan tray
Quick Start installation
Large mounting shelf—Required for all mounting options.
Small mounting shelf—Required only for four-post rack or cabinet
Spacer bars (attached to the back of the front-mounting flanges on the chassis—Required only for four-post rack or cabinet
Blank panels for slots without components installed
1
1
1
2
1
1 or 2 (one for each Routing Engine)
1 or 2
2
1
2
One blank panel for each slot not occupied by a component
126 Copyright © 2018, Juniper Networks, Inc.
Chapter 15: Unpacking the Router
Table 74: Accessory Box Parts List
Part Quantity
Affidavit for T1 connection
Connectors for alarm relay cables
DB-9 (male) to DB-25
(female) adapter
ESD wrist strap with cable
1
2
1
1
Ethernet cable, 15-ft length, to connect Routing Engine to management device
1
PCMCIA Card holder and hook-and-loop fasteners
(male and female)
1 of each
DC power and grounding cable lugs
36 lugs are included.
One lug is for the grounding cable. The remaining cable lugs are for the DC power cables. The number of cable lugs varies depending on the power supply and how many cables are being connected.
Screws to fasten grounding cable to chassis
2
Washers for grounding cable lug
2
Optional cable management restraints
2
Product warranty
Read me first document
1
1
Screws to mount chassis
Serial cable, 6-ft length, to connect Routing Engine to management console
End User License Agreement 1
Bag of 14
1
Related
Documentation
•
Overview of Unpacking the T4000 Router on page 123
•
Unpacking the T4000 Router on page 124
Copyright © 2018, Juniper Networks, Inc.
127
T4000 Core Router Hardware Guide
128 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 16
Installing the Mounting Hardware
•
Installing the T4000 Mounting Hardware for a Four-Post Rack or Cabinet on page 129
•
Installing the T4000 Mounting Hardware for an Open-Frame Rack on page 133
Installing the T4000 Mounting Hardware for a Four-Post Rack or Cabinet
1.
Installing Cage Nuts, if Needed on page 129
2.
Installing the Large Mounting Shelf on page 130
3.
Installing the Small Shelf on page 131
4.
Installing the Spacer Bars on page 132
Installing Cage Nuts, if Needed
To install the cage nuts, if needed, in the mounting holes specified in
1.
On the front rack rails, install cage nuts in the holes specified for the large shelf and the spacer bars.
2.
On the rear rack rails, install cage nuts in the holes specified for the small shelf.
42
33
60
51
The front-mounting flanges have holes for rack-mounting screws, spaced at 5.25 in.
(13.34 cm).
specifies the holes in which you insert mounting screws
(an X indicates a mounting hole location), and cage nuts if needed. The hole distances are relative to one of the standard U divisions on the rack. The bottom of all mounting shelves is at 0.04 in. (0.02 U) above a U division.
Table 75: Four-Post or Cabinet Rack Mounting Hole Locations
Hole Distance Above U Division
Large
Shelf
Spacer
Bars
Small
Shelf
34.75 in. (88.3 cm)
29.51 in. (74.9 cm)
24.26 in. (61.6 cm)
19.01 in. (48.3 cm)
19.86 U
16.86 U
13.86 U
10.86 U
X
X
X
X
Copyright © 2018, Juniper Networks, Inc.
129
T4000 Core Router Hardware Guide
12
9
24
15
6
Table 75: Four-Post or Cabinet Rack Mounting Hole Locations (continued)
Hole Distance Above U Division
Large
Shelf
Spacer
Bars
Small
Shelf
13.76 in. (34.9 cm)
8.51 in. (21.6 cm)
6.76 in. (17.1 cm)
5.01 in. (12.7 cm)
3.26 in. (8.3 cm)
7.86 U
4.86 U
3.86 U
2.86 U
1.86 U
X
X
X
X
X
X
X
3
2
1.51 in. (3.8 cm)
0.88 in. (2.2 cm)
0.86 U
0.50 U X
X
Installing the Large Mounting Shelf
To install the large mounting shelf:
1.
On the front of each front rack rail, partially insert a mounting screw into the lowest hole specified in
for the large shelf and the spacer bars.
2.
Install the large shelf on the front rack rails. Rest the bottom slot of each flange on a mounting screw.
3.
Partially insert a mounting screw into the top hole in each flange of the large shelf.
4.
Tighten all the screws completely.
130 Copyright © 2018, Juniper Networks, Inc.
Chapter 16: Installing the Mounting Hardware
Figure 32: Installing the Mounting Hardware for a Four-Post Rack or Cabinet
Installing the Small Shelf
To install the small shelf:
1.
On the back of each rear rack rail, partially insert a mounting screw into the lowest hole specified in
for the small shelf.
2.
Install the small shelf on the back rack rails. Rest the bottom slot of each flange on a mounting screw. The small shelf installs on the back of the rear rails, extending toward the center of the rack. The bottom of the small shelf on the rear rack rails must align with the bottom of the large shelf on the front rack rails.
3.
Partially insert screws into the open holes in the flanges of the small shelf.
4.
Tighten all the screws completely.
Copyright © 2018, Juniper Networks, Inc.
131
T4000 Core Router Hardware Guide
Installing the Spacer Bars
The router is shipped with each spacer bar attached to the rear of each front-mounting flange.
To install the spacer bars:
1.
Remove each spacer bar by removing the screws that fasten the spacer bar to the front-mounting flange.
2.
Place one of the spacer bars over a flange of the large shelf. Position the notch in the rear of the spacer bar so the upper part of the bar is flush with the rack rail and the lower part is flush with the flange of the shelf (see
3.
Insert a mounting screw into each of the nonthreaded holes in the recesses of the spacer bar to secure the spacer bar. Each hole should have a cage nut behind it.
4.
Repeat Steps
and
for the other spacer bar.
5.
Tighten all the screws completely.
Figure 33: Positioning the Spacer Bar on the Rack
132
Related
Documentation
•
Rack Requirements for the T4000 Router on page 93
•
Installing the T4000 Mounting Hardware for an Open-Frame Rack on page 133
Copyright © 2018, Juniper Networks, Inc.
Chapter 16: Installing the Mounting Hardware
Installing the T4000 Mounting Hardware for an Open-Frame Rack
In an open-frame rack, center-mounting is generally preferable to front-mounting because the more even distribution of weight provides greater stability. If you center-mount the chassis, you use the center-mounting brackets attached to the chassis. If you front-mount the chassis, you use the front-mounting flanges, and must remove the center-mounting brackets.
1.
Installing the Cage Nuts, if Needed on page 133
2.
Installing the Large Mounting Shelf on page 133
3.
Removing the Center-Mounting Brackets from the Chassis on page 134
4.
Removing the Spacer Bars on page 135
Installing the Cage Nuts, if Needed
1.
Check that cage nuts are installed in the mounting holes specified in
2.
Install cage nuts, if needed.
35
32
44
41
31
59
53
50
specifies the mounting holes in which you insert the mounting screws
(an X indicates a mounting hole location), and cage nuts if needed. The hole distances are relative to one of the standard U divisions on the rack. For reference, the bottom of all mounting shelves is at 0.04 in. (0.02 U) above a U division.
Table 76: Open-Frame Rack Mounting Hole Locations
Hole Distance Above U Division Large Shelf
34.13 in. (86.7 cm)
30.63 in. (77.8 cm)
28.88 in. (73.3 cm)
19.50 U
17.50 U
16.50 U
X
X
X
25.38 in. (64.5 cm)
23.63 in. (60.0 cm)
20.13 in. (51.1 cm)
18.38 in. (46.7 cm)
17.75 in. (45.1 cm)
14.50 U
13.50 U
11.50 U
10.50 U
10.14 U
X
X
X
X
X
Installing the Large Mounting Shelf
To install the large mounting shelf (see
Figure 34 on page 134 ) in an open-frame rack:
Copyright © 2018, Juniper Networks, Inc.
133
T4000 Core Router Hardware Guide
1.
On the rear of each rack rail, partially insert a mounting screw into the lowest hole specified in
for the large shelf.
2.
Install the large shelf on the rack. Rest the bottom slot of each flange on a mounting screw.
3.
Partially insert screws into the open holes in the flanges of the large shelf.
4.
Tighten all the screws completely.
Figure 34: Installing the Mounting Hardware for an Open-Frame Rack
Removing the Center-Mounting Brackets from the Chassis
Before front-mounting the router in an open-frame rack, you must remove the center-mounting brackets from the chassis.
To remove the center-mounting brackets (see
):
1.
Loosen the screws at the top and bottom of each bracket.
134 Copyright © 2018, Juniper Networks, Inc.
2.
Remove each bracket.
Figure 35: Removing the Center-Mounting Bracket
Front-mounting flange
Center-mounting bracket
Craft interface
Fan tray
FPCs
CIP
Chapter 16: Installing the Mounting Hardware
ESD point
Air filter
Fan tray
Air intake
Removing the Spacer Bars
The router is shipped with each spacer bar attached to the rear of each front-mounting flange. If you are installing the chassis in an open-frame rack, removing the spacer bars is optional.
To remove the spacer bars:
1.
Remove the screws that fasten the spacer bar to the front-mounting flange
2.
Remove the spacer bars.
Copyright © 2018, Juniper Networks, Inc.
135
T4000 Core Router Hardware Guide
Related
Documentation
•
Rack Requirements for the T4000 Router on page 93
•
Installing the T4000 Mounting Hardware for a Four-Post Rack or Cabinet on page 129
136 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 17
Overview of Installing the Router into a
Rack
•
Overview of Installing the T4000 Router into a Rack on page 137
Overview of Installing the T4000 Router into a Rack
1.
Read the safety information. To avoid harm to yourself or the router as you lift it into the rack, follow the guidelines and safety procedures for working with routers.
See
“T4000 Installation Safety Guidelines” on page 120
and
“General Safety Guidelines and Warnings” on page 393 .
2.
Verify that the site has been prepared for the router installation.
See
“Overview of Preparing the Site for the T4000 Router” on page 87 .
3.
Because of the T4000 router's size and weight—up to 663.6 lb (301.0 kg) fully configured—we strongly recommend that you lift the router into the rack using a mechanical lift. See
“Overview of Installing a T4000 Router Using a Mechanical Lift” on page 139
However, if a mechanical lift is not available, you can remove components from the chassis to make it easier to install into the rack. With components removed, the chassis weighs approximately 240 lb (109 kg), and four people can lift the chassis into the rack manually. See
“Overview of Installing a T4000 Router Without a Mechanical Lift” on page 147 .
Related
Documentation
•
Overview of Installing the T4000 Router on page 119
Copyright © 2018, Juniper Networks, Inc.
137
T4000 Core Router Hardware Guide
138 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 18
Installing the Router into a Rack With a
Mechanical Lift
•
Overview of Installing a T4000 Router Using a Mechanical Lift on page 139
•
Tools Required to Install the T4000 Router Using a Mechanical Lift on page 139
•
Installing the T4000 Router Using a Mechanical Lift on page 140
Overview of Installing a T4000 Router Using a Mechanical Lift
Before installing the router, make sure that you have prepared your site, unpacked the router from the shipping crate, and installed the mounting hardware.
Because of the router's size and weight—up to 663.6 lb (301.0 kg), depending on the configuration—we strongly recommend that you install the router using a mechanical lift.
To install the router:
1.
Gather the tools required to install the router.
See
“Tools Required to Install the T4000 Router Using a Mechanical Lift” on page 139 .
2.
Install the router into the rack using a mechanical lift.
See
“Installing the T4000 Router Using a Mechanical Lift” on page 140
.
Related
Documentation
•
Overview of Installing the T4000 Router into a Rack on page 137
Tools Required to Install the T4000 Router Using a Mechanical Lift
To install the T320 chassis using a mechanical lift, you need the following tools:
• Mechanical lift
• Phillips (+) screwdrivers, number 2
Copyright © 2018, Juniper Networks, Inc.
139
T4000 Core Router Hardware Guide
Related
Documentation
•
Overview of Installing a T4000 Router Using a Mechanical Lift on page 139
•
Installing the T4000 Router Using a Mechanical Lift on page 140
Installing the T4000 Router Using a Mechanical Lift
1.
Removing the T4000 Power Supplies on page 140
2.
Attaching the T4000 Installation Handle on page 141
3.
Installing the T4000 Chassis in a Rack or Cabinet Using a Mechanical Lift on page 141
4.
Removing the T4000 Installation Handle on page 144
5.
Reinstalling the T4000 Power Supplies on page 145
Removing the T4000 Power Supplies
To remove the power supplies, start with the upper power supply:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Loosen the captive screws on the lower corners of the power supply faceplate completely.
3.
Twist the ejector handles on the upper corners of the faceplate counterclockwise to unseat the power supply.
4.
Grasp the handle on the power supply faceplate, and pull firmly to start removing the power supply. Slide it halfway out of the chassis (see
CAUTION: Be prepared to support the full weight of the power supply as you remove it from the router.
5.
Place one hand underneath the power supply to support it, and slide it completely out of the chassis.
6.
Repeat the procedure for the other power supply.
140 Copyright © 2018, Juniper Networks, Inc.
Chapter 18: Installing the Router into a Rack With a Mechanical Lift
Figure 36: Removing a DC Power Supply
Attaching the T4000 Installation Handle
To assist you with the installation of the router, attach the installation handle over the power supply slots of the chassis. To attach the installation handle:
1.
Place the installation handle over the location of the lower power supply.
2.
Tighten the captive screws of the handle into the holes previously occupied by the captive screws of the power supply (see
).
Figure 37: Attaching the Installation Handle
Installing the T4000 Chassis in a Rack or Cabinet Using a Mechanical Lift
Because of the router's size and weight—up to 663.6 lb (301.0 kg) depending on configuration—we strongly recommend that you install the router using a lift.
Copyright © 2018, Juniper Networks, Inc.
141
T4000 Core Router Hardware Guide
To mount the chassis in the rack or cabinet using a lift (see
):
1.
If you are installing the router in an open-frame rack, ensure that the rack is in its permanent location and is secured to the building. Ensure that the installation site allows adequate clearance for both airflow and maintenance. For details, see
Clearance Requirements for Airflow and Hardware Maintenance” on page 91 .
2.
Load the router onto the lift, making sure it rests securely on the lift platform.
CAUTION: Do not lift the router using the installation handle or the handles on the sides of the chassis. Use these handles only to help position the router.
3.
Using the lift, position the chassis in front of the rack or cabinet, centering it in front of the mounting shelves.
4.
Lift the chassis approximately 0.75 in. above the surface of the mounting shelves, and position it as close as possible to the shelves.
5.
Carefully slide the chassis onto the mounting shelves so that the bottom of the chassis and the mounting shelves overlap by approximately 2 inches.
6.
With one person pulling on the installation handle from the rear of the rack or cabinet while two people push on the front-mounting flanges, slide the chassis onto the mounting shelves until the mounting brackets or front-mounting flanges contact the rack rails or spacer bars (depending on your type of installation). The shelves ensure that the holes in the mounting brackets and the front-mounting flanges of the chassis align with the holes in the rack rails.
7.
Move the lift away from the rack.
8.
If you are installing the router in a four-post rack or cabinet, install a mounting screw and a cage nut into each of the holes aligned with the threaded holes in the spacer bars. If you are installing the router in an open-frame rack, install a mounting screw into each of the open mounting holes aligned with the rack, starting from the bottom.
9.
Visually inspect the alignment of the router. If the router is installed properly in the rack, all the mounting screws on one side of the rack should be aligned with the mounting screws on the opposite side and the router should be level.
142 Copyright © 2018, Juniper Networks, Inc.
Figure 38: Lifting the Router
Chapter 18: Installing the Router into a Rack With a Mechanical Lift
Copyright © 2018, Juniper Networks, Inc.
143
T4000 Core Router Hardware Guide
Figure 39: Installing the Router in a Four-Post Rack
NOTE: For an illustration of the mounting hardware required for an open-frame rack, see
“Installing the T4000 Mounting Hardware for an
.
Removing the T4000 Installation Handle
After you have installed the router, remove the installation handle:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Loosen the captive screws on the installation handle completely.
3.
Remove the handle from the chassis.
144 Copyright © 2018, Juniper Networks, Inc.
Chapter 18: Installing the Router into a Rack With a Mechanical Lift
Reinstalling the T4000 Power Supplies
After you have removed the installation handle, reinstall the two power supplies in the chassis, starting with the lower power supply (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Using both hands, slide the power supply into the chassis until you feel resistance.
3.
Twist the ejector handles at the upper corners of the power supply faceplate clockwise until they stop.
4.
Tighten the captive screws at the lower corners of the power supply faceplate to secure the power supply in the chassis.
5.
Repeat the procedure for the upper power supply.
Figure 40: Reinstalling the Power Supplies
Related
Documentation
•
Overview of Installing a T4000 Router Using a Mechanical Lift on page 139
•
Tools Required to Install the T4000 Router Using a Mechanical Lift on page 139
Copyright © 2018, Juniper Networks, Inc.
145
T4000 Core Router Hardware Guide
146 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 19
Installing the Router into a Rack Without a Mechanical Lift
•
Overview of Installing a T4000 Router Without a Mechanical Lift on page 147
•
Tools Required to Install the T4000 Router Without a Mechanical Lift on page 148
•
Removing T4000 Components from the Chassis on page 148
•
Installing the T4000 Chassis in a Rack or Cabinet Manually on page 160
•
Reinstalling the T4000 Components in the Chassis on page 163
Overview of Installing a T4000 Router Without a Mechanical Lift
If you cannot use a mechanical lift to install the T1600 router (the preferred method), you can install it manually. Before installing the router, make sure that you have prepared your site, unpacked the router from the shipping crate, and installed the mounting hardware.
To install the router:
1.
Gather the tools required to install the router.
See
“Tools Required to Install the T4000 Router Without a Mechanical Lift” on page 148 .
2.
Remove components from the chassis to make it easier to install into the rack.
See
“Removing T4000 Components from the Chassis” on page 148 .
3.
Install the router into the rack.
See
“Installing the T4000 Chassis in a Rack or Cabinet Manually” on page 160 .
4.
Reinstall the components removed from the chassis.
See
“Reinstalling the T4000 Components in the Chassis” on page 163
.
Related
Documentation
•
Overview of Installing the T4000 Router into a Rack on page 137
Copyright © 2018, Juniper Networks, Inc.
147
T4000 Core Router Hardware Guide
Tools Required to Install the T4000 Router Without a Mechanical Lift
To install the router, you need the following tools and parts:
• Phillips (+) screwdrivers, numbers 1 and 2
• Flat-blade (–) screwdriver, number 1
• 7/16-in. (11 mm) socket wrench
• 3/8-in. nut driver
• ESD grounding wrist strap
Related
Documentation
•
Overview of Installing a T4000 Router Without a Mechanical Lift on page 147
•
Removing T4000 Components from the Chassis on page 148
•
Installing the T4000 Chassis in a Rack or Cabinet Manually on page 160
•
Reinstalling the T4000 Components in the Chassis on page 163
Removing T4000 Components from the Chassis
To make the router light enough to install manually, you must first remove most components from the chassis. These removal procedures are for the initial installation only, and assume that you have not connected any cables or power to the router.
148 Copyright © 2018, Juniper Networks, Inc.
Chapter 19: Installing the Router into a Rack Without a Mechanical Lift
Figure 41: Components to Remove from the Rear of the T4000 Router
Fan tray
SCGs
Control board 0
Control board 1
SIBs
Power supply 0
Power supply 1
Copyright © 2018, Juniper Networks, Inc.
149
T4000 Core Router Hardware Guide
Figure 42: Components to Remove from the Front of the T4000 Router
Fan tray
FPCs
T Series
FANTRAY-T4000
150
Fan tray
FANTRA
Y-T4000
Remove the components first from the rear of the chassis (
then from the front (
):
1.
Removing the T4000 DC Power Supplies on page 151
2.
Removing the T4000 SIBs on page 152
3.
Removing the T4000 Control Boards on page 153
4.
Removing the T4000 SCGs on page 154
5.
Removing the T4000 Rear Fan Tray on page 155
6.
Removing the T4000 Front Cable Management System on page 156
7.
Removing the T4000 Front Fan Trays on page 157
8.
Removing the T4000 FPCs on page 159
Copyright © 2018, Juniper Networks, Inc.
Chapter 19: Installing the Router into a Rack Without a Mechanical Lift
Removing the T4000 DC Power Supplies
The power supplies are located at the rear of the chassis below the SIBs. Each six-input
DC power supply weighs approximately 39.7 lb (18.0 kg).
To remove the power supplies, starting with the upper power supply:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Loosen the captive screws on the lower corners of the power supply faceplate completely.
3.
Twist the ejector handles on the upper corners of the faceplate counterclockwise to unseat the power supply.
4.
Grasp the handle on the power supply faceplate, and pull firmly to start removing the power supply. Slide it halfway out of the chassis (see
).
5.
Place one hand underneath the power supply to support it, and slide it completely out of the chassis.
CAUTION: Be prepared to support the full weight of the power supply as you remove it from the router.
6.
Repeat the procedure for the other power supply.
Figure 43: Removing a Six-Input DC Power Supply Before Installing the Router
Copyright © 2018, Juniper Networks, Inc.
151
T4000 Core Router Hardware Guide
Removing the T4000 SIBs
Five SIBs are installed in the router. The SIBs are located in the rear of the chassis in the slots marked SIB0 through SIB4 . Each SIB weighs approximately 7.1 lb (3.2 kg).
To remove the SIBs (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
3.
Loosen the captive screws (using a Phillips (+) screwdriver, number 2) on the ejector handles on each side of the SIB faceplate.
4.
Flip the ejector handles outward to unseat the SIB.
5.
Grasp both ejector handles, pull firmly, and slide the SIB about three-quarters of the way out of the chassis.
6.
Place one hand underneath the SIB to support it, and slide it completely out of the chassis. Place it on the antistatic mat.
CAUTION: Do not stack hardware components on one another after you remove them. Place each component on an antistatic mat resting on a stable, flat surface.
7.
Repeat the procedure for each of the remaining SIBs.
152 Copyright © 2018, Juniper Networks, Inc.
Figure 44: Removing a SIB
Chapter 19: Installing the Router into a Rack Without a Mechanical Lift
Removing the T4000 Control Boards
The router has one or two control boards, located in the upper rear of the chassis in the slots marked CB0 and CB1 . Each LCC-CB weighs approximately 5 lb (2.3 kg).
To remove the control boards (see
):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
3.
Loosen the captive screws on the ejector handles on both sides of the control board faceplate.
4.
Flip the ejector handles outward to unseat the control board.
5.
Grasp the ejector handles, and slide the control board about halfway out of the chassis.
6.
Place one hand underneath the control board to support it, and slide it completely out of the chassis. Place it on the antistatic mat.
Copyright © 2018, Juniper Networks, Inc.
153
T4000 Core Router Hardware Guide
CAUTION: Do not stack hardware components on one another after you remove them. Place each component on an antistatic mat resting on a stable, flat surface.
7.
Repeat the procedure for the second control board.
Figure 45: Removing a Control Board
Removing the T4000 SCGs
The router has one or two SCGs, located in the upper rear of the chassis, above the control boards and Routing Engines. Each SCG weighs approximately 1.9 lb (0.9 kg).
To remove the SCGs (see
):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site..
3.
Loosen the captive screws on the edges of the SCG faceplate.
4.
Grasp the SCG by the handle on the faceplate, and slide it out of the chassis.
154 Copyright © 2018, Juniper Networks, Inc.
Chapter 19: Installing the Router into a Rack Without a Mechanical Lift
5.
Place the SCG on the antistatic mat.
6.
Repeat the procedure for the second SCG.
Figure 46: Removing the SCGs
Removing the T4000 Rear Fan Tray
The rear fan tray is mounted vertically on the right side of the rear of the chassis. The rear fan tray weighs about 10 lb (4.5 kg).
To remove the rear fan tray (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Loosen the captive screws on the top and bottom of the fan tray faceplate.
3.
Grasp the handles, and pull the fan tray halfway out of the chassis.
4.
Place one hand under the fan tray to support it, and pull the fan tray completely out of the chassis.
Copyright © 2018, Juniper Networks, Inc.
155
T4000 Core Router Hardware Guide
Figure 47: Removing the Rear Fan Tray
Removing the T4000 Front Cable Management System
The front cable management system is located below the FPC card cage. The cable management system weighs approximately 5 lb (2.3 kg).
To remove the front cable management system:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Using a 3/8-in. nut driver, unscrew the nuts on the corners of the cable management system.
3.
Grasp the bottom of the cable management system, and pull it straight out from the studs on the front of the chassis.
156 Copyright © 2018, Juniper Networks, Inc.
Chapter 19: Installing the Router into a Rack Without a Mechanical Lift
Removing the T4000 Front Fan Trays
The upper front fan tray is located above the FPC card cage, and the lower front fan tray is located below the air filter. Each front fan tray weighs about 20.4 lb (9.3 kg)
To remove the front fan trays (see
and
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Loosen the captive screws on the corners of the faceplate of one of the fan trays.
3.
Grasp the handles, and pull the fan tray halfway out of the chassis.
4.
Place one hand under the fan tray to support it, and pull the fan tray completely out of the chassis.
5.
Repeat the procedure to remove the remaining front fan tray.
Copyright © 2018, Juniper Networks, Inc.
157
T4000 Core Router Hardware Guide
Figure 48: Removing an Upper Front Fan Tray
FANTRAY-T4000
T Series
FANTRAY-T4000
158
FANTRA
Y-T4000
Figure 49: Removing a Lower Front Fan Tray
FANTRAY-T4000
Copyright © 2018, Juniper Networks, Inc.
Chapter 19: Installing the Router into a Rack Without a Mechanical Lift
Removing the T4000 FPCs
The router holds up to eight FPCs, which are installed vertically in the front of the router.
An FPC with PICs installed can weigh up to 33.5 lb (15.1 kg).
Each FPC slot not occupied by an FPC must be covered by an FPC blank panel. An FPC blank panel weighs 9 lb (4.2 kg).
To remove an FPC (see
):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
3.
Before removing the FPCs, record their location in the chassis so that you can reinstall each FPC in the correct slot.
4.
Simultaneously turn both the ejector handles counterclockwise to unseat the FPC.
5.
Grasp the handles, and slide the FPC straight out of the card cage halfway.
6.
Place one hand around the front of the FPC (the PIC housing) and the other hand under it to support it. Slide the FPC completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.
CAUTION: The weight of the FPC is concentrated in the back end. Be prepared to accept the full weight—up to 33.5 lb (15.1 kg)—as you slide the FPC out of the chassis.
When the FPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
Do not stack FPCs on top of one another after removal. Place each one individually in an electrostatic bag or on its own antistatic mat on a flat, stable surface.
7.
Repeat the procedure for each remaining FPC.
Copyright © 2018, Juniper Networks, Inc.
159
T4000 Core Router Hardware Guide
Figure 50: Removing an FPC
T-1600 FPC4
Related
Documentation
•
Overview of Installing a T4000 Router Without a Mechanical Lift on page 147
•
Installing the T4000 Chassis in a Rack or Cabinet Manually on page 160
•
Reinstalling the T4000 Components in the Chassis on page 163
•
Prevention of Electrostatic Discharge Damage on page 423
Installing the T4000 Chassis in a Rack or Cabinet Manually
To install the router in the rack (see
):
CAUTION: If you are installing two routers in one rack, install the lower one first. Installing a router in the upper position in a rack or cabinet requires a lift.
160 Copyright © 2018, Juniper Networks, Inc.
Chapter 19: Installing the Router into a Rack Without a Mechanical Lift
CAUTION: Before front-mounting the router in a rack, have a qualified technician verify that the rack is strong enough to support the router's weight and is adequately supported at the installation site.
CAUTION: Lifting the chassis and mounting it in a rack requires four people.
1.
For open-frame racks, ensure that the rack is in its permanent location and is secured to the building.
2.
Ensure that the installation site allows adequate clearance for both airflow and maintenance.
3.
Attach the installation handle by tightening the captive screws of the handle into the holes previously occupied by the captive screws of the power supplies (see
Figure 51 on page 161 ). Tighten the screws, using a Phillips (+) screwdriver, number 2.
Figure 51: Attaching the Installation Handle
CAUTION: Do not lift the router using the installation handle or the handles on the sides of the chassis. Use these handles only to help position the router.
4.
Position the router in front of the rack or cabinet, centering it in front of the mounting shelves. Use a pallet jack if one is available.
5.
With two people in the front and two people in the back, hold onto the bottom of the chassis, and carefully lift it onto the mounting shelves.
Copyright © 2018, Juniper Networks, Inc.
161
T4000 Core Router Hardware Guide
WARNING: To prevent injury, keep your back straight and lift with your legs, not your back. Avoid twisting your body as you lift. Balance the load evenly, and be sure that your footing is solid.
6.
With one person pulling on the installation handle from the rear of the rack or cabinet while two people push on the front-mounting flanges, slide the router onto the mounting shelves until the mounting brackets or front-mounting flanges contact the rack rails or spacer bars (depending on your type of installation). The shelves ensure that the holes in the mounting brackets and the front-mounting flanges of the chassis align with the holes in the rack rails.
7.
If you are installing the router in a four-post rack or cabinet, install a mounting screw and a cage nut into each of the holes aligned with the threaded holes in the spacer bars. If you are installing the router in an open-frame rack, install a mounting screw into each of the open mounting holes aligned with the rack, starting from the bottom.
8.
Loosen the captive screws on the installation handle completely, and remove the handle from the chassis.
9.
Visually inspect the alignment of the router. If the router is installed properly in the rack, all the mounting screws on one side of the rack should be aligned with the mounting screws on the opposite side and the router should be level.
162 Copyright © 2018, Juniper Networks, Inc.
Chapter 19: Installing the Router into a Rack Without a Mechanical Lift
Figure 52: Installing the Router in the Rack
NOTE: For an illustration of the mounting hardware required for an open-frame rack, see
“Installing the T4000 Mounting Hardware for an
.
Related
Documentation
•
T4000 Clearance Requirements for Airflow and Hardware Maintenance on page 91
•
Overview of Installing a T4000 Router Without a Mechanical Lift on page 147
•
Removing T4000 Components from the Chassis on page 148
•
Reinstalling the T4000 Components in the Chassis on page 163
•
Prevention of Electrostatic Discharge Damage on page 423
Reinstalling the T4000 Components in the Chassis
After the router is installed in the rack, you reinstall the removed components before cabling, booting, and configuring the router.
Copyright © 2018, Juniper Networks, Inc.
163
T4000 Core Router Hardware Guide
The procedures describe how to reinstall components in the chassis, first in the rear and then in the front:
1.
Reinstalling the Rear Fan Tray on page 164
2.
Reinstalling the T4000 SCGs on page 165
3.
Reinstalling the T4000 Control Boards on page 166
4.
Reinstalling the T4000 SIBs on page 167
5.
Reinstalling the Power Supplies on page 168
6.
Reinstalling the FPCs on page 169
7.
Reinstalling T4000 Front Fan Trays on page 170
8.
Reinstalling the T4000 Front Cable Management System on page 171
Reinstalling the Rear Fan Tray
To install a replacement rear fan tray (see
1.
Grasp the fan tray by its handles, and insert it straight into the chassis.
2.
Tighten the captive screws on the fan tray faceplate to secure it in the chassis, using a Phillips (+) screwdriver, number 2.
164 Copyright © 2018, Juniper Networks, Inc.
Chapter 19: Installing the Router into a Rack Without a Mechanical Lift
Figure 53: Reinstalling the Rear Fan Tray
Reinstalling the T4000 SCGs
To reinstall the SCGs (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Carefully align the sides of the SCG with the guides in the SCG slot.
3.
Grasp the SCG by its handle, and slide it straight into the chassis until it contacts the midplane.
Copyright © 2018, Juniper Networks, Inc.
165
T4000 Core Router Hardware Guide
4.
Tighten the captive screws on the corners of the SCG faceplate.
5.
Repeat the procedure to reinstall the remaining SCG.
Figure 54: Reinstalling an SCG
Reinstalling the T4000 Control Boards
To reinstall the control boards (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Carefully align the sides of the control boards with the guides inside the chassis.
3.
Slide the control boards into the chassis, carefully ensuring that it is correctly aligned.
4.
Grasp both ejector handles and press them inward to seat the control board.
5.
Tighten the captive screws on the ejector handles, using a Phillips (+) screwdriver, number 2.
6.
Repeat the procedure to reinstall the remaining control board.
166 Copyright © 2018, Juniper Networks, Inc.
Chapter 19: Installing the Router into a Rack Without a Mechanical Lift
Figure 55: Reinstalling an LCC-CB
Reinstalling the T4000 SIBs
To reinstall the SIBs (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Place one hand underneath the SIB to support it. With the other hand, hold one of the ejector handles on the SIB faceplate.
3.
Carefully align the sides of the SIB with the guides inside the chassis.
4.
Slide the SIB into the chassis, carefully ensuring that it is correctly aligned.
5.
Grasp both ejector handles and press them inward to seat the SIB.
6.
Tighten the captive screws on the ejector handles.
7.
Repeat the procedure for each of the remaining SIBs.
Copyright © 2018, Juniper Networks, Inc.
167
T4000 Core Router Hardware Guide
Figure 56: Reinstalling a T4000 SIB
Reinstalling the Power Supplies
Reinstall the lower power supply first, then the upper power supply. To reinstall the DC power supplies (see
):
1.
Using both hands, slide the power supply into the chassis until you feel resistance.
2.
Twist the ejector handles at the upper corners of the power supply faceplate clockwise until they stop.
3.
Tighten the captive screws at the lower corners of the power supply faceplate to secure the power supply in the chassis.
4.
Repeat the procedure for the upper power supply.
168 Copyright © 2018, Juniper Networks, Inc.
Chapter 19: Installing the Router into a Rack Without a Mechanical Lift
Figure 57: Reinstalling a Six-Input DC Power Supply
Reinstalling the FPCs
To reinstall FPCs (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Using the list you created when you removed the FPCs, locate the slot in the FPC card cage in which you plan to install the FPC.
3.
Lift the FPC into place and carefully align first the bottom, then the top of the FPC with the guides inside the card cage. Be sure the FPC is right-side up, with the components on the right of the FPC.
CAUTION: When the FPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
4.
Slide the FPC all the way into the card cage until you feel resistance.
5.
Starting with the ejector handles on the FPC faceplate nearly horizontal, simultaneously turn both ejector handles clockwise to seat the FPC.
6.
Repeat the procedure to reinstall each remaining FPC.
Copyright © 2018, Juniper Networks, Inc.
169
T4000 Core Router Hardware Guide
Figure 58: Reinstalling an FPC
T-1600 FPC4
Reinstalling T4000 Front Fan Trays
To reinstall the front fan trays (see
and
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Grasp one of the fan trays by its handles, and insert it straight into the chassis.
3.
Tighten the captive screw on each side of the fan tray faceplate to secure it in the chassis.
4.
Repeat the procedure to reinstall the remaining fan tray.
170 Copyright © 2018, Juniper Networks, Inc.
Chapter 19: Installing the Router into a Rack Without a Mechanical Lift
Figure 59: Reinstalling an Upper Front Fan Tray
T Series
FANTRAY-T4000
FANTRAY-T4000
Figure 60: Reinstalling a Lower Front Fan Tray
FANTRAY-T4000
Reinstalling the T4000 Front Cable Management System
To reinstall the front cable management system:
1.
Position the front cable management system on the studs on the lower front of the chassis.
2.
Insert the nuts through the holes in the cable management system onto the studs on the chassis.
3.
Using a 3/8-in. nut driver, tighten the nuts securely.
Related
Documentation
•
Overview of Installing a T4000 Router Without a Mechanical Lift on page 147
•
Removing T4000 Components from the Chassis on page 148
•
Prevention of Electrostatic Discharge Damage on page 423
Copyright © 2018, Juniper Networks, Inc.
171
T4000 Core Router Hardware Guide
172 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 20
Connecting the Router to Ground
•
Tools and Parts Required to Ground the T4000 Router on page 173
•
Connecting the T4000 Grounding Cable on page 174
Tools and Parts Required to Ground the T4000 Router
• Grounding cable (which you must provide)
• Grounding lug (provided with the router)
Figure 61: Grounding Lug
• M6 screws or UNC 1/4-20 screws
• Electrostatic discharge (ESD) grounding wrist strap
Related
Documentation
• Overview of Grounding the T4000 Router
•
Connecting the T4000 Grounding Cable on page 174
Copyright © 2018, Juniper Networks, Inc.
173
T4000 Core Router Hardware Guide
Connecting the T4000 Grounding Cable
You ground the router by connecting a grounding cable to earth ground and then attaching it to the chassis grounding points with two screws. You must provide the grounding cable
(a cable lug is supplied with the router). To connect the grounding cable (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Make sure that grounding surfaces are clean and brought to a bright finish before grounding connections are made.
3.
Connect the grounding cable to a proper earth ground.
4.
Verify that a licensed electrician has attached the cable lug provided with the router to the grounding cable.
5.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
6.
Place the grounding cable lug over the grounding points. The left pair is sized for M6 screws, and the right pair is sized for UNC 1/4-20 screws.
7.
Secure the grounding cable lug to the grounding points, first with the washers, then with the screws.
8.
Verify that the grounding cabling is correct, that the grounding cable does not touch or block access to router components, and that it does not drape where people could trip on it.
174 Copyright © 2018, Juniper Networks, Inc.
Figure 62: Connecting the Grounding Cable
Chapter 20: Connecting the Router to Ground
Grounding points
(on chassis)
Related
Documentation
• Overview of Grounding the T4000 Router
•
Tools and Parts Required to Ground the T4000 Router on page 173
•
T4000 Chassis Grounding Cable and Lug Specifications on page 90
Copyright © 2018, Juniper Networks, Inc.
175
T4000 Core Router Hardware Guide
176 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 21
Connecting the Router to External Devices
•
Overview of Connecting the T4000 Router to External Devices on page 177
•
Tools and Parts Required to Connect the T4000 Router to External Devices on page 178
•
Connecting the T4000 Router to a Management Console or Auxiliary Device on page 178
•
Connecting the T4000 Router to a Management Ethernet Device on page 180
•
Connecting the T4000 Router to an External Alarm-Reporting Device on page 182
•
Connecting PIC Cables to the T4000 Router on page 183
Overview of Connecting the T4000 Router to External Devices
After you have grounded the T4000 Core Router, you can connect the following external devices:
• An external console or auxiliary device to the CONSOLE ports on the Connector Interface
Panel (CIP).
See
“Connecting the T4000 Router to a Management Console or Auxiliary Device” on page 178 .
• A laptop, modem, or other auxiliary device to the AUXILIARY ports on the CIP.
See
“Connecting the T4000 Router to a Management Console or Auxiliary Device” on page 178 .
• A management network to the ETHERNET ports on the CIP.
See
“Connecting the T4000 Router to a Management Ethernet Device” on page 180 .
• An external alarm-reporting device to the alarm relay contacts on the CIP.
See
“Connecting the T4000 Router to an External Alarm-Reporting Device” on page 182 .
• An external clocking device to the EXTERNAL CLOCK INPUTS on the SONET Clock
Generator with RJ-48 ports.
See Connecting the T4000 Router to an External Clocking Device .
Copyright © 2018, Juniper Networks, Inc.
177
T4000 Core Router Hardware Guide
NOTE: The external clock inputs on the SCG with DB-9 ports are not supported.
• A network connection to the ports on the PICs.
See
“Connecting PIC Cables to the T4000 Router” on page 183
.
Related
Documentation
•
Overview of Installing the T4000 Router on page 119
Tools and Parts Required to Connect the T4000 Router to External Devices
To connect the router to external devices, you need the following tools:
• Phillips (+) screwdrivers, numbers 1 and 2
• 2.5-mm flat-blade (-) screwdriver
• Electrostatic discharge (ESD) grounding wrist strap
Related
Documentation
•
Overview of Connecting the T4000 Router to External Devices on page 177
•
Connecting the T4000 Router to a Management Console or Auxiliary Device on page 178
•
Connecting the T4000 Router to an External Alarm-Reporting Device on page 182
• Connecting the T4000 Router to an External Clocking Device
•
Connecting PIC Cables to the T4000 Router on page 183
Connecting the T4000 Router to a Management Console or Auxiliary Device
To use a system console to configure and manage the Routing Engine, connect it to the appropriate CONSOLE port on the CIP. To use a laptop, modem, or other auxiliary device, connect it to the appropriate AUXILIARY port on the CIP. Both ports accept an RS-232
(EIA-232) serial cable with a DB-9 female connector. One DB-9/DB-9 cable is provided with the router. To connect a device to the CONSOLE port, and another device to the
AUXILIARY port, you must supply another cable.
To connect a management console or auxiliary device:
1.
Turn off the power to the console or auxiliary device.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Connect one end (shown in
) of a serial cable with a DB-9 female connector to the appropriate CONSOLE or AUXILIARY port (see
The ports labeled HOST 0 connect to the Routing Engine in the upper Routing Engine
178 Copyright © 2018, Juniper Networks, Inc.
Chapter 21: Connecting the Router to External Devices slot ( RE0 ), and the ports labeled HOST 1 connect to the Routing Engine in the lower
Routing Engine slot ( RE1 ).
NOTE:
For console devices, configure the serial port to the following values:
• Baud rate—9600
• Parity—N
• Data bits—8
• Stop bits—1
• Flow control—none
4.
Using a 2.5-mm flat-blade screwdriver, tighten the screws on the connector.
5.
Attach the other end of the cable to the console or auxiliary device.
Figure 63: Console and Auxiliary Serial Port Connector
Copyright © 2018, Juniper Networks, Inc.
179
T4000 Core Router Hardware Guide
Figure 64: Console and Auxiliary Ports on the CIP
Related
Documentation
•
T4000 Connector Interface Panel (CIP) Description on page 14
•
Overview of Connecting the T4000 Router to External Devices on page 177
Connecting the T4000 Router to a Management Ethernet Device
To connect the Routing Engine to a network for out-of-band management, connect an
Ethernet with RJ-45 connectors to the ETHERNET port on the CIP. One cable is provided with the router.
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Turn off the power to the management device.
3.
Plug one end of the Ethernet cable ( Figure 65 on page 181
shows the connector) into the appropriate ETHERNET port on the CIP (see
Figure 66 on page 181 ). The ports
180 Copyright © 2018, Juniper Networks, Inc.
Chapter 21: Connecting the Router to External Devices labeled HOST 0 connect to the Routing Engine in the upper Routing Engine slot ( RE0 ), and the ports labeled HOST 1 connect to the Routing Engine in the lower Routing
Engine slot ( RE1 ).
4.
Plug the other end of the cable into the network device.
Figure 65: Routing Engine Ethernet Cable Connector
Figure 66: ETHERNET Port on the CIP
Related
Documentation
•
T4000 Connector Interface Panel (CIP) Description on page 14
•
Overview of Connecting the T4000 Router to External Devices on page 177
Copyright © 2018, Juniper Networks, Inc.
181
T4000 Core Router Hardware Guide
Connecting the T4000 Router to an External Alarm-Reporting Device
To connect the router to external alarm-reporting devices, attach wires to the RED ALARM and YELLOW ALARM relay contacts on the CIP. A system condition that triggers the red or yellow alarm LED on the craft interface also activates the corresponding alarm relay contact.
The terminal blocks that plug into the alarm relay contacts are supplied with the router.
They accept wire of any gauge between 28-AWG and 14-AWG (0.08 and 2.08 mm
2
), which is not provided. Use the gauge of wire appropriate for the external device you are connecting.
To connect an external device to an alarm relay contact:
1.
Prepare the required length of wire with gauge between 28-AWG and 14-AWG (0.08
and 2.08 mm
2
).
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
While the terminal block is not plugged into the relay contact, use a 2.5-mm flat-blade screwdriver to loosen the small screws on its side. With the small screws on its side facing left, insert wires into the slots in the front of the block based on the wiring for the external device. Tighten the screws to secure the wire.
4.
Orient the terminal block according to the labels to the left of the appropriate relay contact ( NC means “normally closed, C means “common,” and ( NO means “normally open”).
5.
Plug the terminal block into the relay contact and use a 2.5-mm flat-blade screwdriver to tighten the screws on the face of the block.
6.
Attach the other end of the wires to the external device.
If attaching a reporting device for the other kind of alarm, repeat the procedure.
Related
Documentation
•
T4000 Connector Interface Panel (CIP) Description on page 14
•
Overview of Connecting the T4000 Router to External Devices on page 177
182 Copyright © 2018, Juniper Networks, Inc.
Chapter 21: Connecting the Router to External Devices
Connecting PIC Cables to the T4000 Router
The router supports PICs that use various kinds of network cable, including multimode and single-mode fiber-optic cable.
You connect PICs to the network by plugging in network cable. To connect cable to the
PICs (see
Figure 67 on page 184 , which shows a fiber-optic PIC):
1.
Have ready a length of the type of cable used by the PIC. For cable specifications, see
Determining Transceiver Support and Specifications for M Series and T Series Routers in the T4000 Core Router Interface Module Reference .
2.
If the PIC cable connector port is covered by a rubber safety plug, remove the plug.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
3.
Insert the cable connector into the cable connector port on the PIC faceplate.
4.
Arrange the cable in the cable management system to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop.
Placing fasteners on the loop helps to maintain its shape.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
Copyright © 2018, Juniper Networks, Inc.
183
T4000 Core Router Hardware Guide
Figure 67: Attaching a Cable to a PIC
PIC
Fiber-optic cable
Related
Documentation
•
T4000 PIC Description on page 62
•
Overview of Connecting the T4000 Router to External Devices on page 177
184 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 22
Connecting the Router to Power
•
Tools and Parts Required to Provide Power to the T4000 Router on page 185
•
Connecting DC Power to the T4000 Router (Six 60-A Inputs) on page 186
•
Connecting DC Power to the T4000 Router (Five 60-A Inputs) on page 190
•
Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 194
•
Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A
Tools and Parts Required to Provide Power to the T4000 Router
To connect the router to power, you need the following tools and parts:
• DC-powered routers: 7/16-in. (11 mm) hexagonal-head external drive nut driver, with a torque range between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm), for tightening nuts to terminal studs on each power supply on a DC-powered router.
• Torque-controlled tool.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 in-lb (5.0 Nm).
• DC power cables and lugs. See
“T4000 DC Power Cable and Lugs Specifications” on page 105 .
Related
Documentation
•
Connecting DC Power to the T4000 Router (Six 60-A Inputs) on page 186
•
Connecting DC Power to the T4000 Router (Five 60-A Inputs) on page 190
•
Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 194
•
Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A
Copyright © 2018, Juniper Networks, Inc.
185
T4000 Core Router Hardware Guide
Connecting DC Power to the T4000 Router (Six 60-A Inputs)
You connect DC power to the router by attaching power cables from the DC power sources to the terminal studs on the power supply faceplates. You must provide power cables
(the cable lugs are supplied with the router).
CAUTION: All connected inputs on the DC power supply in slot PEM0 must be powered by dedicated power feeds derived from feed A, and all connected inputs on the DC power supply in slot PEM1 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed A/B feed redundancy for the system.
NOTE: We recommend that the positive (+) DC source power cables for the
RTN (return) terminals be 2.6 in. (6.6 cm) longer than the negative (–) DC source power cables for the –48 V (input) terminals.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
To connect DC source power cables to the router, follow this procedure for each DC power supply:
1.
Verify that a properly rated customer site circuit breaker for each DC power cable has been installed. See the DC power electrical safety guidelines for your router for more information.
2.
Switch off the customer site circuit breakers. Ensure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cable leads might become active during installation.
186 Copyright © 2018, Juniper Networks, Inc.
Chapter 22: Connecting the Router to Power
3.
Verify that a licensed electrician has attached appropriate cable lugs to the DC power cables. See the DC power cable and lug specifications for your router for more information.
4.
Switch the power switch on the power supply faceplate to the standby position.
5.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
6.
Remove the nut and washer from each power terminal stud to be connected. If no washers and nuts are already installed, they should be in the accessory box.
7.
Remove the captive screws on all three cable restraints on the right edge of the power supply faceplate (using a Phillips (+) screwdriver, number 2).
8.
Route the negative (–) DC source power cables for INPUT 0 , INPUT 1 , INPUT 3 , and
INPUT 4 over the smallest cable restraint on the far right. The cable restraint is marked as follows top to bottom: INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 .
NOTE: You must route the cables in the locations as marked to be able to replace the clear plastic cover over the terminal studs.
Figure 68: Connecting DC Power Cables
Cable lug
Terminal studs
Locking washer
Nut
Attach the negative (–) DC source power cable lugs INPUT 0 , INPUT 1 , INPUT 3 , and
INPUT 4 to the –48 V (input) terminals on the right. Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
Copyright © 2018, Juniper Networks, Inc.
187
T4000 Core Router Hardware Guide
Figure 69: Connecting Negative (–) DC Power Cables to INPUT 0, INPUT 1, INPUT 3, and
INPUT 4
9.
Replace the smallest cable restraint on the far right, and tighten the captive screw to hold the power cables for INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 in place.
10.
Route the negative (–) DC source power cables for INPUT 2 and INPUT 5 through the middle cable restraint. The middle cable restraint is marked as follows from top to bottom: INPUT 2 , RTN 2 , RTN 5 , and INPUT 5 .
NOTE: You must route the cables in the locations as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the negative (–) DC source power cable lugs to the –48 V (input) terminals on the right. Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
Figure 70: Connecting Negative (–) DC Power Cables to INPUT 2 and INPUT 5
188
11.
Route the positive (+) DC source power cables for RTN 2 and RTN 5 over the middle cable restraint. The middle cable restraint is marked as follows from top to bottom:
INPUT 2 , RTN 2 , RTN 5 , and INPUT 5 .
Copyright © 2018, Juniper Networks, Inc.
Chapter 22: Connecting the Router to Power
NOTE: You must route the cables as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the positive (+) DC source power cable lugs RTN 2 and RTN 5 to the RTN
(return) terminals on the left. Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts.
Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
12.
Replace the middle cable restraint, and tighten the captive screw to hold the power cables for INPUT 2 , INPUT 5 , RTN 2 , and RTN 5 in place.
13.
Route the positive (+) DC source power cables for RTN 0 , RTN 1 , RTN 3 , and RTN 4 over the largest cable restraint on the left. The left cable restraint is marked as follows from top to bottom: RTN 0 , RTN 1 , RTN 3 , and RTN 4 .
NOTE: You must route the cables as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the positive (+) DC source power cable lugs to the RTN 0 , RTN 1 , RTN 3 , and
RTN 4 terminals on the left. Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
14.
Replace the left cable restraint, and tighten the captive screw to hold the power cables for RTN 0 , RTN 1 , RTN 3 , and RTN 4 in place.
Figure 71: Connecting Positive (+) DC Power Cables to RTN 2, RTN 5, RTN 0, RTN 1, RTN 3, and RTN 4
15.
Verify that the power cabling is correct, that the power cables are not touching or blocking access to router components, and that they do not drape where people could trip on them.
16.
Replace the clear plastic cover over the terminal studs on the faceplate.
Copyright © 2018, Juniper Networks, Inc.
189
T4000 Core Router Hardware Guide
Related
Documentation
•
Tools and Parts Required to Provide Power to the T4000 Router on page 185
•
Connecting DC Power to the T4000 Router (Five 60-A Inputs) on page 190
•
Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 194
•
Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A
•
Powering On the T4000 Router on page 207
•
Configuring DC Power on a T4000 Router on page 213
•
Troubleshooting the T4000 Power System on page 363
•
T4000 DC Power Electrical Safety Guidelines on page 424
•
T4000 DC Power Cable and Lugs Specifications on page 105
Connecting DC Power to the T4000 Router (Five 60-A Inputs)
You connect DC power to the router by attaching power cables from the DC power sources to the terminal studs on the power supply faceplates. You must provide power cables
(the cable lugs are supplied with the router).
CAUTION: Do not use a terminal jumper for 60-A DC power cables. Using a terminal jumper is not supported for this procedure. Doing so will cause a short across the inputs and trip your external circuit breaker.
CAUTION: All connected inputs on the DC power supply in slot PEM0 must be powered by dedicated power feeds derived from feed A, and all connected inputs on the DC power supply in slot PEM1 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed A/B feed redundancy for the system.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
190 Copyright © 2018, Juniper Networks, Inc.
Chapter 22: Connecting the Router to Power
NOTE: We recommend that the positive (+) DC source power cables to be connected to the RTN (return) terminals be 2.6 in. (6.6 cm) longer than the negative (–) DC source power cables to be connected to the –48 V (input) terminals.
To connect five 60-A DC source power cables to the router, follow this procedure for each DC power supply:
1.
Verify that a properly rated customer site circuit breaker for each DC power cable has been installed. See the DC power electrical safety guidelines for your router for more information.
2.
Switch off the customer site circuit breakers. Ensure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cable leads might become active during installation.
3.
Verify that a licensed electrician has attached appropriate cable lugs to the DC power cables. See the DC power cable and lug specifications for your router for more information.
4.
Switch the power switch on the power supply faceplate to the standby position.
5.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
6.
Remove the nut and washer from each power terminal stud to be connected. If no washers and nuts are already installed, they should be in the accessory box.
7.
Remove the captive screws on all three cable restraints on the right edge of the power supply faceplate (using a Phillips (+) screwdriver, number 2).
8.
Route the negative (–) DC source power cables for INPUT 0 , INPUT 1 , INPUT 3 , and
INPUT 4 , over the smallest cable restraint on the far right. The cable restraint is marked as follows top to bottom: INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 ,
NOTE: You must route the cables in the locations as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the negative (–) DC source power cable lugs to the –48V (input) terminals on the right: INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 . Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
Copyright © 2018, Juniper Networks, Inc.
191
T4000 Core Router Hardware Guide
Figure 72: Connecting DC Power Cables
Cable lug
Terminal studs
Locking washer
Nut
Figure 73: Connecting Negative (–) DC Power Cables to INPUT 0, INPUT 1, INPUT 3, and
INPUT 4
9.
Replace the smallest cable restraint on the far right, and tighten the captive screw to hold the power cables for INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 in place.
10.
Route the negative (–) DC source power cables for INPUT 2 , through the middle cable restraint. The middle cable restraint is marked as follows from top to bottom: INPUT
2 , RTN 2 , RTN 5 , and INPUT 5 .
NOTE: You must route the cable in the location as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the negative (–) DC source power cable lugs to the INPUT 2 –48 V (input) terminal on the right. Secure the cable lug to the terminal studs, first with the washer, then with the nut. Using a 7/16-in. (11 mm) nut driver, tighten the nut. Apply between
23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
192 Copyright © 2018, Juniper Networks, Inc.
Chapter 22: Connecting the Router to Power
Figure 74: Connecting Negative (–) DC Power Cable to INPUT 2
11.
Route the positive (+) DC source power cables for RTN 2 over the middle cable restraint. The middle cable restraint is marked as follows from top to bottom: INPUT
2 , RTN 2 , RTN 5 , and INPUT 5 ,
NOTE: You must route the cables as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the positive (+) DC source power cable lug to the RTN 2 (return) terminal on the left. Secure the cable lug to the terminal stud, first with the washer, then with the nut. Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6
Nm) and 25 lb-in. (2.8 Nm) of torque to the nut.
12.
Replace the middle cable restraint, and tighten the captive screw to hold the power cables for INPUT 2 and RTN 2 in place.
13.
Route the positive (+) DC source power cables for RTN 0 , RTN 1 , RTN 3 , and RTN 4 over the largest cable restraint on the left. The left cable restraint is marked as follows from top to bottom RTN 0 , RTN 1 , RTN 3 , and RTN 4 ,
NOTE: You must route the cables as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the positive (+) DC source power cable lugs to the RTN terminals on the left:
RTN 0 , RTN 1 , RTN 3 , and RTN 4 . Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts.
Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
14.
Replace the left cable restraint, and tighten the captive screw to hold the power cables for RTN 0 , RTN 1 , RTN 3 , and RTN 4 in place.
Copyright © 2018, Juniper Networks, Inc.
193
T4000 Core Router Hardware Guide
Figure 75: Connecting Positive (+) DC Power Cable to RTN 2, RTN 0, RTN 1, RTN 3, RTN 4
15.
Verify that the power cabling is correct, that the power cables are not touching or blocking access to router components, and that they do not drape where people could trip on them.
16.
Replace the clear plastic cover over the terminal studs on the faceplate.
Related
Documentation
•
Tools and Parts Required to Provide Power to the T4000 Router on page 185
•
Connecting DC Power to the T4000 Router (Six 60-A Inputs) on page 186
•
Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 194
•
Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A
•
Powering On the T4000 Router on page 207
•
Configuring DC Power on a T4000 Router on page 213
•
T4000 DC Power Electrical Safety Guidelines on page 424
•
T4000 DC Power Cable and Lugs Specifications on page 105
Connecting DC Power to the T4000 Router (Four 60-A Inputs)
You connect DC power to the router by attaching power cables from the DC power sources to the terminal studs on the power supply faceplates. You must provide power cables
(the cable lugs are supplied with the router).
CAUTION: Do not use a terminal jumper for 60-A DC power cables. Using a terminal jumper is not supported for this procedure. Doing so will cause a short across the inputs and trip your external circuit breaker.
CAUTION: All connected inputs on the DC power supply in slot PEM0 must be powered by dedicated power feeds derived from feed A, and all connected
194 Copyright © 2018, Juniper Networks, Inc.
Chapter 22: Connecting the Router to Power inputs on the DC power supply in slot PEM1 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed A/B feed redundancy for the system.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
NOTE: We recommend that the positive (+) DC source power cables to be connected to the RTN (return) terminals be 2.6 in. (6.6 cm) longer than the negative (–) DC source power cables to be connected to the –48 V (input) terminals.
To connect four 60-A DC source power cables to the router, follow this procedure for each DC power supply:
1.
Check your planned hardware configuration and verify that four 60-A DC source power cables will provide sufficient power. See the DC power requirements for your router for more information.
2.
Verify that a properly rated customer site circuit breaker for each DC power cable has been installed. See the DC power electrical safety guidelines for your router for more information.
3.
Switch off the customer site circuit breakers. Ensure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cable leads might become active during installation.
4.
Verify that a licensed electrician has attached appropriate cable lugs to the DC power cables. See the DC power cable and lug specifications for your router for more information.
5.
Switch the power switch on the power supply faceplate to the standby position.
Copyright © 2018, Juniper Networks, Inc.
195
T4000 Core Router Hardware Guide
6.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
7.
Remove the nut and washer from each power terminal stud to be connected ( INPUT
0 , INPUT 1 , INPUT 3 , INPUT 4 , and RTN 0 , RTN 1 , RTN 3 , and RTN 4 ). If no washers and nuts are already installed, they should be in the accessory box.
8.
Remove the captive screws on the smallest cable restraint on the right edge of the power supply faceplate, and the largest cable restraint to the left (using a Phillips (+) screwdriver, number 2).
9.
Route the negative (–) DC source power cables for INPUT 0 , INPUT 1 , INPUT 3 , and
INPUT 4 , over the smallest cable restraint on the far right. The cable restraint is marked as follows top to bottom: INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 .
NOTE: You must route the cables in the locations as marked to be able to replace the clear plastic cover over the terminal studs.
Figure 76: Connecting DC Power Cables
Cable lug
Terminal studs
Locking washer
Nut
Attach the negative (–) DC source power cable lugs to the –48V (input) terminals on the right: INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 . Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
Figure 77: Connecting Negative (–) DC Power Cables to INPUT 0, INPUT 1. INPUT 3, and
INPUT 4
196 Copyright © 2018, Juniper Networks, Inc.
Chapter 22: Connecting the Router to Power
10.
Replace the smallest cable restraint on the far right, and tighten the captive screw to hold the power cables for INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 in place.
11.
Route the positive (+) DC source power cables for RTN 0 , RTN 1 , RTN 3 , and RTN 4 over the largest cable restraint on the left. The left cable restraint is marked as follows from top to bottom: RTN 0 , RTN 1 , RTN 3 , and RTN 4 ,
NOTE: You must route the cables as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the negative (–) DC source power cable lugs to the RTN terminals on the left:
RTN 0 , RTN 1 , RTN 3 , and RTN 4 . Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts.
Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
12.
Replace the left cable restraint, and tighten the captive screw to hold the power cables for RTN 0 , RTN 1 , RTN 3 , and RTN 4 in place.
Figure 78: Connecting Positive (+) DC Power Cables to RTN 0, RTN 1, RTN 3, and RTN 4
13.
Verify that the power cabling is correct, that the power cables are not touching or blocking access to router components, and that they do not drape where people could trip on them.
14.
Replace the clear plastic cover over the terminal studs on the faceplate.
Related
Documentation
•
Tools and Parts Required to Provide Power to the T4000 Router on page 185
•
Connecting DC Power to the T4000 Router (Six 60-A Inputs) on page 186
•
Connecting DC Power to the T4000 Router (Five 60-A Inputs) on page 190
•
Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A
•
Powering On the T4000 Router on page 207
•
Configuring DC Power on a T4000 Router on page 213
Copyright © 2018, Juniper Networks, Inc.
197
T4000 Core Router Hardware Guide
•
T4000 DC Power Requirements on page 97
•
T4000 Power Management (Four 60-A Cables on a Six-Input DC Power Supply) on page 103
•
T4000 Power Management (Three 80-A Cables on a Six-Input DC Power Supply) on page 103
•
Troubleshooting the T4000 Power System on page 363
•
T4000 DC Power Electrical Safety Guidelines on page 424
•
T4000 DC Power Cable and Lugs Specifications on page 105
Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A
Inputs)
You connect DC power to the router by using a terminal jumper to attach one DC power cable from the DC power source to two terminal studs on the power supply faceplate.
Use the terminal jumper kit (model number PWR-T-BUS-BAR-S) to perform this procedure (terminal jumpers might also be referred to as bus bars). The terminal jumper kit contains the terminal jumpers and the new clear plastic cover required to accommodate the terminal jumpers. Six terminal jumpers are required for each power supply. You must provide power cables (the cable lugs are supplied with the router).
CAUTION: When using a terminal jumper for this procedure, terminate only a single DC power cable to the two input terminals using the terminal jumper as shown in
and
Figure 83 on page 203 . Do not connect
two DC power cables using a terminal jumper to two inputs as shown in
Figure 79 on page 198 . Connecting two DC power cables using a terminal
jumper to two inputs will cause a short across the inputs and trip your external circuit breaker.
Figure 79: Incorrect Cable Connection to INPUT 1
198
CAUTION: All connected inputs on the DC power supply in slot PEM0 must be powered by dedicated power feeds derived from feed A, and all connected
Copyright © 2018, Juniper Networks, Inc.
Chapter 22: Connecting the Router to Power inputs on the DC power supply in slot PEM1 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed A/B feed redundancy for the system.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
NOTE: We recommend that the positive (+) DC source power cables to be connected to the RTN (return) terminals be 2.6 in. (6.6 cm) longer than the negative (–) DC source power cables to be connected to the –48 V (input) terminals.
To connect 80-A DC source power cables to six inputs using a terminal jumper, follow this procedure for each DC power supply:
1.
Check your planned hardware configuration, and verify that three 80-A DC source power cables will provide sufficient power. See the DC power requirements for your router for more information.
2.
Verify that a properly rated customer site circuit breaker for each DC power cable has been installed. See the DC power electrical safety guidelines for your router for more information.
3.
Switch off the customer site circuit breakers. Ensure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cable leads might become active during installation.
4.
Verify that a licensed electrician has attached appropriate cable lugs to the DC power cables. See the DC power cable and lug specifications for your router for more information.
5.
Switch the power switch on the power supply faceplate to the standby position.
Copyright © 2018, Juniper Networks, Inc.
199
T4000 Core Router Hardware Guide
6.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
NOTE: You will replace this cover with the new cover provided in the terminal jumper kit (model number PWR-T-BUS-BAR-S). The new cover is labeled 2 in
.
7.
Remove the nut and washer from each power terminal stud to be connected. If no washers and nuts are already installed, they should be in the accessory box.
8.
Remove the captive screws on all three cable restraints on the right edge of the power supply faceplate (using a Phillips (+) screwdriver, number 2).
9.
Place one terminal jumper over the negative (–) DC INPUT 0 and INPUT 1 terminals on the right.
NOTE: The terminal jumpers are located in the terminal jumper kit (model number PWR-T-BUS-BAR-S).
Figure 80: Terminal Jumper
10.
Place a washer, and then a nut on the negative (–) DC INPUT 0 terminal.
Using a 7/16-in. (11 mm) nut driver, tighten the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
200 Copyright © 2018, Juniper Networks, Inc.
Chapter 22: Connecting the Router to Power
Figure 81: Connecting DC Power Cables
Jumper
Nut
Locking washer
Cable lug
Terminal studs
Grounding points
(on chassis)
11.
Route the negative (–) DC source power cable for INPUT 1 over the smallest cable restraint on the far right.
NOTE: The smallest cable restraint is marked as follows from top to bottom: INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 . You must route the cables in the locations as marked to be able to install the new clear plastic cover over the terminal studs.
Attach the negative (–) DC source power cable lug to the –48 V (input) INPUT 1 terminal on the right. Secure the cable lug to the terminal stud, first with the washer, then with the nut.
12.
Place one terminal jumper over the negative (–) DC INPUT 2 and INPUT 3 input terminals on the right.
13.
Place a washer, and then a nut on the negative (–) DC INPUT 2 terminal.
Using a 7/16-in. (11 mm) nut driver, tighten the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to the nut.
Copyright © 2018, Juniper Networks, Inc.
201
T4000 Core Router Hardware Guide
14.
Route the negative (–) DC source power cable for INPUT 3 over the smallest cable restraint on the far right.
Attach the negative (–) DC source power cable lug to the –48 V (input) INPUT 3 terminal on the right. Secure the cable lug to the terminal stud, first with the washer, then with the nut.
Using a 7/16-in. (11 mm) nut driver, tighten the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to the nut.
Figure 82: Negative (–) DC Power Cables Connected to INPUT 1 and INPUT 3
202
15.
Replace the smallest cable restraint on the far right, and tighten the captive screw to hold the power cables for INPUT 1 and INPUT 3 in place.
16.
Place one terminal jumper over the negative (–) DC INPUT 4 and INPUT 5 input terminals on the right.
17.
Place a washer, and then a nut on the negative (–) DC INPUT 4 terminal.
Using a 7/16-in. (11 mm) nut driver, tighten the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to the nut.
18.
Route the negative (–) DC source power cable for INPUT 5 through the middle cable restraint.
NOTE: The middle cable restraint is marked as follows from top to bottom:
INPUT 2 , RTN 2 , RTN 5 , and INPUT 5 . You must route the cable in the location as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the negative (–) DC source power cable lug to the –48 V (input) INPUT 5 terminal on the right. Secure the cable lug to the terminal studs, first with the washers, then with the nuts.
Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
Copyright © 2018, Juniper Networks, Inc.
Chapter 22: Connecting the Router to Power
Figure 83: Connecting Negative (–) DC Power Cable to INPUT 5
19.
Place one terminal jumper over the positive (+) DC RTN 4 and RTN 5 input terminals on the left
20.
Place a washer, and then a nut on RTN 4 .
Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
21.
Route the positive (+) DC source power cable for the RTN 5 input terminal through the middle cable restraint.
NOTE: The middle cable restraint is marked as follows from top to bottom:
INPUT 2 , RTN 2 , RTN 5 , and INPUT 5 . You must route the cables as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the positive (+) DC source power cable lug to the RTN 5 RTN (return) terminal on the left. Secure the cable lug to the terminal stud, first with the washer, then with the nut.
Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
22.
Replace the middle cable restraint, and tighten the captive screw to hold the power cables for INPUT 5 and RTN 5 in place.
23.
Place one terminal jumper over RTN 0 and RTN 1 .
24.
Place a washer, and then a nut on RTN 0 .
Using a 7/16-in. (11 mm) nut driver, tighten the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
25.
Route the positive (+) DC source power cable for RTN 1 over the largest cable restraint on the left.
Copyright © 2018, Juniper Networks, Inc.
203
T4000 Core Router Hardware Guide
NOTE: The large left cable restraint is marked as follows from top to bottom: RTN 0 , RTN 1 , RTN 3 , and RTN 4 . You must route the cables as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the positive (+) DC source power cable lugs to the RTN 1 terminal on the left.
Secure the cable lugs to the terminal stud, first with the washer, then with the nut.
Using a 7/16-in. (11 mm) nut driver, tighten the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
26.
Place terminal jumper over RTN 2 and RTN 3 .
27.
Place a washer, and then a nut on RTN 2 .
Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
28.
Route the positive (+) DC source power cable for RTN 3 over the largest cable restraint on the left.
NOTE: The large left cable restraint is marked as follows from top to bottom: RTN 0 , RTN 1 , RTN 3 , and RTN 4 . You must route the cables as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the positive (+) DC source power cable lug to the RTN 3 terminal on the left.
Secure the cable lug to the terminal stud, first with the washer, then with the nut.
Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
29.
Replace the large left cable restraint, and tighten the captive screw to hold the power cables for RTN 1 and RTN 3 in place.
Figure 84: Positive (+) DC Power Cables Connected to RTN 1, RTN 3, and RTN 5
204 Copyright © 2018, Juniper Networks, Inc.
Chapter 22: Connecting the Router to Power
30.
Verify that the power cabling is correct, that the power cables are not touching or blocking access to router components, and that they do not drape where people could trip on them.
31.
Install the clear plastic terminal jumper cover (labeled 2 in
located in the terminal jumper kit (model number PWR-T-BUS-BAR-S) to protect the terminal studs on the faceplate.
NOTE: You must use the terminal jumper cover provided in the terminal jumper kit (model number PWR-T-BUS-BAR-S) to ensure there is no access to the terminal jumpers and for proper cable alignment. The terminal jumper cover (labeled 2 in
) has three cable openings and is longer than the original clear plastic cover (labeled 1 in
) that has six cable openings.
Figure 85: Power Supply Covers
1 2
Related
Documentation
•
Tools and Parts Required to Provide Power to the T4000 Router on page 185
•
Connecting DC Power to the T4000 Router (Six 60-A Inputs) on page 186
•
Connecting DC Power to the T4000 Router (Five 60-A Inputs) on page 190
•
Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 194
•
Powering On the T4000 Router on page 207
•
Configuring DC Power on a T4000 Router on page 213
•
Troubleshooting the T4000 Power System on page 363
•
T4000 DC Power Requirements on page 97
•
T4000 Power Management (Four 60-A Cables on a Six-Input DC Power Supply) on page 103
Copyright © 2018, Juniper Networks, Inc.
205
T4000 Core Router Hardware Guide
•
T4000 Power Management (Three 80-A Cables on a Six-Input DC Power Supply) on page 103
•
T4000 DC Power Electrical Safety Guidelines on page 424
•
T4000 DC Power Cable and Lugs Specifications on page 105
206 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 23
Powering On the Router
•
Powering On the T4000 Router on page 207
Powering On the T4000 Router
To power on the DC-powered T4000 router:
1.
Verify that the power supplies are fully inserted in the chassis and that the captive screws on their faceplates are tightened.
2.
Verify that the source power cables are connected to the appropriate terminal: the positive (+) source cable to the return terminal (labeled RTN ) and the negative (–) source cable to the input terminal (labeled –48V ).
3.
Verify that an external management device is connected to one of the Routing Engine ports on the CIP ( AUXILIARY , CONSOLE , or ETHERNET ).
NOTE: If you are powering on the router for the first time, the AUXILIARY and ETHERNET ports do not function until after the initial configuration procedure.
4.
Turn on the power to the external management device.
5.
Switch on the dedicated customer site circuit breakers to provide power to the DC power cables. Follow your site’s procedures.
6.
Verify that the INPUT PRESENT LED for each input on the DC power supply faceplate is lit steadily green, indicating that the inputs are receiving power.
7.
Switch the power switch on the power supply to the ON position ( — ). The DC OK LED blinks momentarily, then lights steadily.
Copyright © 2018, Juniper Networks, Inc.
207
T4000 Core Router Hardware Guide
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the LEDs on the power supply, the command output displays, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
8.
Verify that the DC OK LED on the DC power supply faceplate is lit steadily, indicating that power supply is correctly installed and functioning properly.
9.
On the external management device connected to the Routing Engine, monitor the startup process to verify that the router has booted properly.
10.
Repeat the procedure for the other power supply.
Figure 86: Six-Input DC Power Supply
208
Related
Documentation
•
Connecting DC Power to the T4000 Router (Six 60-A Inputs) on page 186
•
Connecting DC Power to the T4000 Router (Five 60-A Inputs) on page 190
•
Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 194
•
Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A
•
Powering Off the T4000 Router on page 341
Copyright © 2018, Juniper Networks, Inc.
CHAPTER 24
Configuring the JUNOS Software
•
Initially Configuring the T4000 Router on page 209
•
Configuring DC Power on a T4000 Router on page 213
Initially Configuring the T4000 Router
These procedures connect a router to the network but do not enable it to forward traffic.
For complete information about enabling the router to forward traffic, including examples, see the Junos OS configuration guides.
You configure the router by issuing Junos OS command-line interface (CLI) commands, either on a console device attached to the CONSOLE port, or over a telnet connection to a network connected to the ETHERNET port.
NOTE: These procedures enable you to use the ETHERNET management port. For the initial configuration, use a device attached to the CONSOLE port.
1.
Preparing to Configure the Router on page 209
2.
Entering Configuration Mode on page 210
3.
Configuring User Accounts and Passwords on page 210
4.
Configuring System Attributes on page 210
5.
Committing the Configuration on page 212
Preparing to Configure the Router
Gather the following information before configuring the router:
• Name the router will use on the network
• Domain name the router will use
• IP address and prefix length information for the Ethernet interface
• IP address of a default router
• IP address of a DNS server
• Password for the root user
Copyright © 2018, Juniper Networks, Inc.
209
T4000 Core Router Hardware Guide
Entering Configuration Mode
1.
Verify that the network device is powered on.
2.
Log in as the root user. There is no password.
Amnesiac <ttyd0> login: root
3.
Start the CLI.
root@% cli root>
4.
Enter configuration mode.
root> configure
Entering configuration mode.
[edit] root#
Configuring User Accounts and Passwords
For information about using an encrypted password or an SSH public key string (DSA or
RSA), see Configuring the Root Password and authentication (Login) .
1.
Add a password to the root administration user account. Enter a cleartext password.
[edit] root@host# set system root-authentication plain-text-password
New password: password
Retype new password: password
2.
Create a management console user account.
[edit] root@host# set system login user user-name authentication plain-text-password
New Password: password
Retype new password: password
3.
Set the user account class to super-user .
[edit] root@host# set system login user user-name class super-user
Configuring System Attributes
For more information on configuring the backup routing and static routes, see the Junos
OS Administration Library .
1.
Configure the name of the router. If the name includes spaces, enclose the name in quotation marks (“ ”).
210 Copyright © 2018, Juniper Networks, Inc.
Chapter 24: Configuring the JUNOS Software
[edit] root@host# set system host-name host-name
NOTE: The DNS server does not use the hostname to resolve to the correct
IP address. This hostname is used only to display the name of the routing engine in the CLI. For example, this hostname shows on the command-line prompt when the user is logged on to the CLI:
[edit]
user-name@host-name>
2.
Configure the IP address of the DNS server.
[edit] root# set system name-server address
3.
Configure the router’s domain name.
[edit] root# set system domain-name domain-name
4.
Configure the IP address and prefix length for the router’s management Ethernet interface.
NOTE: The RE-C1800 Routing Engine ( RE-DUO-1800 ) does not support the fxp0 management Ethernet interface or the fxp1 and fxp2 internal
Ethernet interfaces. Use the em0 interface for the RE-C1800 Routing
Engine.
[edit] root# set interfaces em0 unit 0 family inet address address/prefix-length
5.
Configure the IP address of a backup routing engine. The backup routing engine is used while the local router is booting and if the routing process fails to start. After the routing process starts, the backup routing engine address is removed from the local routing and forwarding tables.
[edit] root# set system backup-router address
6.
(Optional) Configure the static routes to remote subnets with access to the management port. Access to the management port is limited to the local subnet. To access the management port from a remote subnet, you must add a static route to that subnet within the routing table.
[edit] root# set routing-options static route remote-subnet next-hop destination-IP retain no-readvertise
Copyright © 2018, Juniper Networks, Inc.
211
T4000 Core Router Hardware Guide
7.
Configure the telnet service at the [edit system services] hierarchy level.
[edit] set system services telnet
Committing the Configuration
1.
Display the configuration to verify that it is correct.
[edit] root# show system { host-name host-name; domain-name domain-name; backup-router address; root-authentication {
authentication-method (password | public-key);
} name-server {
address;
}
} interfaces { fxp0 { unit 0 { family inet { address address/prefix-length;
}
}
}
}
2.
Commit the configuration to activate it on the router.
[edit] root# commit
3.
Optionally, configure additional properties by adding the necessary configuration statements. Then commit the changes to activate them on the router.
[edit] root# commit
4.
When you have finished configuring the router, exit configuration mode.
[edit] root# exit
Related
Documentation
•
Powering On the T4000 Router on page 207
•
T4000 Router Description on page 3
212 Copyright © 2018, Juniper Networks, Inc.
Chapter 24: Configuring the JUNOS Software
Configuring DC Power on a T4000 Router
After you have connected the DC power and initially configured the router, you must configure the number of input feeds if you connected fewer than six cables to the six-input
DC power supply. You must also configure the input current for the DC power supply if you connected three 80-A cables to the six-input DC power supply.
For more information about configuring the DC power supply and the commands used in the procedures, see the T4000 Power Management Overview in the Junos OS
Administration Library .
•
Configuring DC Power on a T4000 Router (Five 60-A Cables on a Six-Input DC Power
•
Configuring DC Power on a T4000 (Four 60-A Cables on a Six-Input DC Power
•
Configuring DC Power on a T4000 (Three 80-A Cables on a Six-Input DC Power
Configuring DC Power on a T4000 Router (Five 60-A Cables on a Six-Input DC Power Supply)
When you connect five cables on a six-input DC power supply, you must specify the number of input feeds connected in the software. If the number of physical input feeds receiving power does not match the number of configured input feeds, the router displays an alarm message.
1.
Configure the number of input feeds to indicate that five DC power cables are connected.
[edit] user@host# set chassis pem feeds 5
NOTE: The default number of input feeds is 6.
2.
(Optional) Use the show statement to display the configuration to verify that it is correct.
[edit] user@host# show pem { feeds 5;
}
3.
Commit the configuration to activate it on the router, and exit configuration mode.
[edit] user@host# commit user@host# exit user@host>
Copyright © 2018, Juniper Networks, Inc.
213
T4000 Core Router Hardware Guide
See Also
Configuring DC Power on a T4000 (Four 60-A Cables on a Six-Input DC Power Supply)
When you connect four cables on a six-input DC power supply, you must specify the number of input feeds connected in the software. If the number of physical input feeds receiving power does not match the number of configured input feeds, the router displays an alarm message.
1.
Configure the number of input feeds to indicate that four DC power cables are connected.
[edit] user@host# set chassis pem feeds 4
NOTE: The default number of input feeds is 6.
2.
(Optional) If the power has been underprovisioned for your configuration, some FPCs might not be brought online if the available power capacity is exceeded. When you reboot the router, FPCs are brought online based on the default setting of the fru-poweron-sequence command. You can use the fru-poweron-sequence command to change the default order in which FPCs are brought online when the router is rebooted. The default sequence is the numerical order of the FPC slots (0 through 7).
[edit] user@host# set chassis fru-poweron-sequence fru-poweron-sequence
3.
(Optional) Use the show statement to display the configuration to verify that it is correct.
[edit] user@host# show pem { feeds 4;
}
4.
Commit the configuration to activate it on the router, and exit configuration mode.
[edit] user@host# commit user@host# exit user@host>
214 Copyright © 2018, Juniper Networks, Inc.
Chapter 24: Configuring the JUNOS Software
Configuring DC Power on a T4000 (Three 80-A Cables on a Six-Input DC Power Supply)
When you connect three 80-A DC power cables to six inputs using terminal jumpers to each power supply, you must specify the input current in the software. In addition, you must also indicate that six input feeds are used. If the number of physical input feeds receiving power does not match the number of configured inputs, the router displays an alarm message.
1.
Configure the number of input feeds to indicate that six feeds are used to connect the three 80-A DC power cables by means of terminal jumpers.
[edit] user@host# set chassis pem feeds 6
NOTE: The default number of input feeds is 6.
2.
Configure the input current to indicate that 40-A is used to provide input current. Each
80-A DC power cable connects to two inputs by means of a terminal jumper, with each input receiving approximately 40 amps.
[edit] user@host# set chassis pem input-current 40
NOTE: The default input current is 60-A.
3.
(Optional) If the power has been underprovisioned for your configuration, some FPCs might not be brought online if the available power capacity is exceeded. When you reboot the router, FPCs are brought online based on the default setting of the fru-poweron-sequence command. You can use the fru-poweron-sequence command to change the default order in which FPCs are brought online when the router is rebooted.
[edit] user@host# set chassis fru-poweron-sequence fru-poweron-sequence
NOTE: The default is the numerical order of the FPC slots (0 through 7).
4.
(Optional) Use the show statement to display the configuration to verify that it is correct.
[edit] user@host# show pem { feeds 6; input-current 40;
}
Copyright © 2018, Juniper Networks, Inc.
215
T4000 Core Router Hardware Guide
5.
Commit the configuration to activate it on the router and exit configuration mode.
[edit] user@host# commit user@host# exit user@host>
Related
Documentation
•
T4000 Power System Description on page 75
•
Connecting DC Power to the T4000 Router (Five 60-A Inputs) on page 190
•
Connecting DC Power to the T4000 Router (Four 60-A Inputs) on page 194
•
Connecting DC Power to the T4000 Router (Three 80-A DC Power Cables to Six 60-A
•
Troubleshooting the T4000 Power System on page 363
•
T4000 DC Power Requirements on page 97
•
T4000 Power Management (Four 60-A Cables on a Six-Input DC Power Supply) on page 103
•
T4000 Power Management (Three 80-A Cables on a Six-Input DC Power Supply) on page 103
• T4000 Power Management Overview
216 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 25
Upgrading to a T4000 Router From a
T640 or T1600 Router
•
Overview of Preparing to Upgrade to a T4000 Router on page 217
•
Checking the Hardware Version of T640 or T1600 Components on page 218
•
•
Overview of Upgrading to a T4000 Router on page 227
•
Upgrading Hardware Components on the T640 or T1600 Router on page 228
•
Upgrading to T4000 SIBs with Junos OS Release 12.1 on page 232
•
Upgrading to T4000 SIBs Online with Junos OS Release 12.2 and Later on page 233
•
Installing the T4000 FPCs After an Upgrade from a T640 or T1600 Router on page 235
•
Registering Your T4000 Upgrade on page 236
Overview of Preparing to Upgrade to a T4000 Router
To prepare to upgrade to a T4000 router:
1.
Prepare the installation site for the T4000 router.
See
“Overview of Preparing the Site for the T4000 Router” on page 87 .
2.
Determine which model numbers of the following components are already installed.
See
“Checking the Hardware Version of T640 or T1600 Components” on page 218
.
• Routing Engines: RE-DUO-C1800-8G or RE-DUO-C1800-16G (supported on T640 or T1600 router)
• Control boards: CB-LCC (supported on T640 or T1600 router)
• Rear fan tray: FAN-REAR-TXP-LCC (supported on T1600 router only)
• Power supplies: PWR-T-6-60-DC (supported on T640 or T1600 router)
3.
Order the required hardware.
The hardware upgrade kit includes two LCC-CBs, two RE-DUO-CI800-8G Routing
Engines, five SIB-I-T4000 SIBs, one FAN-REAR-TXP-LCC rear fan trays, two
FANTRAY-T4000 front fan trays, and two PWR-T-6-60-DC power supplies. If the
Copyright © 2018, Juniper Networks, Inc.
217
T4000 Core Router Hardware Guide required control boards, Routing Engines, rear fan tray, or power supplies are already installed in the T640 or T1600 router, you can also order the other hardware components separately.
See the
“T4000 Upgrade Kit” on page 227 .
4.
Review all safety guidelines and warnings for both the T4000 router and T1600 router or T640 Router.
WARNING: To avoid harm to yourself or the router as you install and maintain it, you must follow the safety procedures for working with Internet routers, as well as the guidelines and warnings for working with and near electrical equipment. However, providing an exhaustive set of guidelines for working with electrical equipment is beyond the scope of this documentation.
See
“General Safety Guidelines and Warnings” on page 393
and General Safety Warnings for Juniper Networks Devices .
5.
Upgrade the software on the T1600 router or T640 router to Junos OS Release 12.1
or later. Support of some hardware or software features require Junos OS Release
12.1R2 or later. For information about upgrading the software, see the Installation and
Upgrade Guide .
6.
Delete unsupported configurations from the T640 or T1600 router.
For example, the following CoS configuration is not supported for T4000 routers:
Hierarchy Level [edit class-of-service schedulers scheduler-name] drop-profile-map loss-priority (any | low | medium-low | medium-high | high) protocol (any| non-tcp | tcp) drop-profile profile-name.
For the T4000 router, any is the only protocol option supported for the following statement. The non-tcp and tcp options are not supported,
Hierarchy Level [edit class-of-service schedulers scheduler-name] drop-profile-map loss-priority (any | low | medium-low | medium-high | high) protocol any drop-profileprofile-name.
Related
Documentation
•
T4000 Router Description on page 3
•
T4000 Hardware Component Overview on page 5
Checking the Hardware Version of T640 or T1600 Components
1.
Checking the Hardware Version of the Control Boards on page 219
2.
Checking the Hardware Version of the Routing Engines on page 221
218 Copyright © 2018, Juniper Networks, Inc.
Chapter 25: Upgrading to a T4000 Router From a T640 or T1600 Router
3.
Checking the Hardware Version of the Rear Fan Tray on page 223
4.
Checking the Hardware Version of the FPCs on page 224
Checking the Hardware Version of the Control Boards
The control board model number LCC-CB is required for the T4000 router.
The following control boards are not supported for the T4000 router:
• CB-L-T
• CB-T
To determine which model numbers of control boards are installed:
1.
Issue the show chassis hardware models command:
In this example, the output shows that two CB-L-T control boards are installed.
user@host> show chassis hardware models
Hardware inventory:
Item Version Part number FRU model number
Midplane REV 04 710-002726 CHAS-BP-T640-S
FPM Display REV 02 710-002897 CRAFT-T640-S
CIP REV 05 710-002895 CIP-L-T640-S
PEM 0 Rev 01 740-002595 PWR-T-DC-S
SCG 0 REV 04 710-003423 SCG-T-S
SCG 1 REV 04 710-003423 SCG-T-S
Routing Engine 0 REV 01 740-005022 RE-600-2048-S
Routing Engine 1 REV 07 740-005022 RE-600-2048-S
CB 0 REV 06 710-002726 CB-L-T-S
CB 1 REV 06 710-002728 CB-L-T-S
FPC 5 REV 05 710-007527 T640-FPC2
PIC 0 REV 05 750-002510 PB-2GE-SX
PIC 1 REV 05 750-001901 PB-4OC12-SON-SMIR
FPC 6 REV 03 710-001721 T640-FPC3
PIC 1 REV 01 750-009553 PC-4OC48-SON-SFP
SIB 4 REV 02 750-005486 SIB-I-T640-S
Fan Tray 0 FANTRAY-T-S
Fan Tray 1 FANTRAY-T-S
Fan Tray 2 FAN-REAR-TX-T640-S
In this example, the output shows that two CB-T control boards are installed.
user@host> show chassis hardware models
Hardware inventory:
Item Version Part number FRU model number
Midplane REV 03 710-005608 CHAS-BP-T640-S
FPM Display REV 05 710-002897 CRAFT-T640-S
CIP REV 06 710-002895 CIP-L-T640-S
PEM 0 Rev 07 740-017906 PWR-T1600-3-80-DC-S
PEM 1 Rev 18 740-002595 PWR-T-DC-S
SCG 0 REV 15 710-003423 SCG-T-S
Routing Engine 0 REV 08 740-014082 RE-A-2000-4096-S
Routing Engine 1 REV 07 740-014082 RE-A-2000-4096-S
CB 0 REV 05 710-007655 CB-T-S
CB 1 REV 03 710-017707 CB-T-S
Copyright © 2018, Juniper Networks, Inc.
219
T4000 Core Router Hardware Guide
220
FPC 0 REV 07 710-013558 T640-FPC2-E2
PIC 0 REV 01 750-010618 PB-4GE-SFP
PIC 1 REV 06 750-001900 PB-1OC48-SON-SMSR
PIC 2 REV 14 750-001901 PB-4OC12-SON-SMIR
PIC 3 REV 07 750-001900 PB-1OC48-SON-SMSR
FPC 1 REV 06 710-013553 T640-FPC1-E2
PIC 0 REV 08 750-001072 P-1GE-SX
PIC 1 REV 10 750-012266 PB-4GE-TYPE1-SFP-IQ2
PIC 2 REV 22 750-005634 PB-1CHOC12SMIR-QPP
FPC 2
PIC 0 REV 16 750-007141 PC-10GE-SFP
PIC 1 REV 06 750-015217 PC-8GE-TYPE3-SFP-IQ2
PIC 2 REV 05 750-004695 PC-TUNNEL
PIC 3 REV 17 750-009553 PC-4OC48-SON-SFP
FPC 3 REV 01 710-010154 T640-FPC3-E
PIC 0 REV 07 750-012793 PC-1XGE-TYPE3-XFP-IQ2
PIC 1 REV 25 750-007141 PC-10GE-SFP
PIC 2 REV 17 750-009553 PC-4OC48-SON-SFP
PIC 3 REV 32 750-003700 PC-1OC192-SON-VSR
FPC 4 REV 16 710-013037 T1600-FPC4-ES
PIC 1 REV 06 750-034781 PD-1CE-CFP
FPC 5 REV 02 710-013037 T1600-FPC4-ES
PIC 0 REV 16 750-012518 PD-4OC192-SON-XFP
PIC 1 REV 01 750-010850 PD-1OC768-SON-SR
FPC 6 REV 14 710-013037 T1600-FPC4-ES
PIC 0 REV 11 750-017405 PD-4XGE-XFP
PIC 1 REV 13 750-017405 PD-4XGE-XFP
FPC 7 REV 09 710-007529 T640-FPC3
PIC 0 REV 10 750-012793 PC-1XGE-TYPE3-XFP-IQ2
PIC 1 REV 01 750-015217 PC-8GE-TYPE3-SFP-IQ2
PIC 2 REV 01 750-015217 PC-8GE-TYPE3-SFP-IQ2
PIC 3 REV 15 750-009450 PC-1OC192-SON-SR2
SIB 0 REV 07 710-013074 SIB-I-T1600-S
SIB 1 REV 07 710-013074 SIB-I-T1600-S
SIB 2 REV 07 710-013074 SIB-I-T1600-S
SIB 3 REV 07 710-013074 SIB-I-T1600-S
SIB 4 REV 07 710-013074 SIB-I-T1600-S
Fan Tray 0 FANTRAY-T-S
Fan Tray 1 FANTRAY-T-S
Fan Tray 2 FAN-REAR-TX-T640-S
In this example, the output shows that LCC-CB control boards are installed.
Fans Top Left Front fan OK Spinning at normal speed
Top Left Middle fan OK Spinning at normal speed
Top Left Rear fan OK Spinning at normal speed
Top Right Front fan OK Spinning at normal speed
Top Right Middle fan OK Spinning at normal speed
Top Right Rear fan OK Spinning at normal speed
Bottom Left Front fan OK Spinning at normal speed
Bottom Left Middle fan OK Spinning at normal speed
Bottom Left Rear fan OK Spinning at normal speed
Bottom Right Front fan OK Spinning at normal speed
Bottom Right Middle fan OK Spinning at normal speed
Copyright © 2018, Juniper Networks, Inc.
Chapter 25: Upgrading to a T4000 Router From a T640 or T1600 Router
Bottom Right Rear fan OK Spinning at normal speed
Rear Tray Top fan OK Spinning at normal speed
Rear Tray Second fan OK Spinning at normal speed
Rear Tray Third fan OK Spinning at normal speed
Rear Tray Fourth fan OK Spinning at normal speed
Rear Tray Fifth fan OK Spinning at normal speed
Rear Tray Sixth fan OK Spinning at normal speed
Rear Tray Seventh fan OK Spinning at normal speed
Rear Tray Bottom fan OK Spinning at normal speed
2.
If two LCC-CB control boards are not installed, order and install LCC-CB control boards.
Checking the Hardware Version of the Routing Engines
The Routing Engine model number RE-DUO-C1800-8G or RE-DUO-C1800-16G is required for the T4000 router. The following Routing Engines are not supported on the T4000 router:
• RE-600-2048
• RE-1600-2048
• RE-A-2000-4096
To determine which model numbers of Routing Engines are installed:
1.
Issue the show chassis hardware models command:
In this example, the output shows that two RE-600-2048 Routing Engines are installed.
user@host> show chassis hardware models user@host> show chassis hardware models
Hardware inventory:
Item Version Part number FRU model number
Midplane REV 04 710-002726 CHAS-BP-T640-S
FPM Display REV 02 710-002897 CRAFT-T640-S
CIP REV 05 710-002895 CIP-L-T640-S
PEM 0 Rev 01 740-002595 PWR-T-DC-S
SCG 0 REV 04 710-003423 SCG-T-S
SCG 1 REV 04 710-003423 SCG-T-S
Routing Engine 0 REV 01 740-005022 RE-600-2048-S
Routing Engine 1 REV 07 740-005022 RE-600-2048-S
CB 0 REV 06 710-002726 CB-L-T-S
CB 1 REV 06 710-002728 CB-L-T-S
FPC 5 REV 05 710-007527 T640-FPC2
PIC 0 REV 05 750-002510 PB-2GE-SX
PIC 1 REV 05 750-001901 PB-4OC12-SON-SMIR
FPC 6 REV 03 710-001721 T640-FPC3
PIC 1 REV 01 750-009553 PC-4OC48-SON-SFP
SIB 4 REV 02 750-005486 SIB-I-T640-S
Fan Tray 0 FANTRAY-T-S
Fan Tray 1 FANTRAY-T-S
Fan Tray 2 FAN-REAR-TX-T640-S
In this example, the output shows that two RE-A-2000-4096 Routing Engines are installed.
Copyright © 2018, Juniper Networks, Inc.
221
T4000 Core Router Hardware Guide user@host> show chassis hardware models
Hardware inventory:
Item Version Part number FRU model number
Midplane REV 03 710-005608 CHAS-BP-T640-S
FPM Display REV 05 710-002897 CRAFT-T640-S
CIP REV 06 710-002895 CIP-L-T640-S
PEM 0 Rev 07 740-017906 PWR-T1600-3-80-DC-S
PEM 1 Rev 18 740-002595 PWR-T-DC-S
SCG 0 REV 15 710-003423 SCG-T-S
Routing Engine 0 REV 08 740-014082 RE-A-2000-4096-S
Routing Engine 1 REV 07 740-014082 RE-A-2000-4096-S
CB 0 REV 05 710-007655 CB-T-S
CB 1 REV 03 710-017707 CB-T-S
FPC 0 REV 07 710-013558 T640-FPC2-E2
PIC 0 REV 01 750-010618 PB-4GE-SFP
PIC 1 REV 06 750-001900 PB-1OC48-SON-SMSR
PIC 2 REV 14 750-001901 PB-4OC12-SON-SMIR
PIC 3 REV 07 750-001900 PB-1OC48-SON-SMSR
FPC 1 REV 06 710-013553 T640-FPC1-E2
PIC 0 REV 08 750-001072 P-1GE-SX
PIC 1 REV 10 750-012266 PB-4GE-TYPE1-SFP-IQ2
PIC 2 REV 22 750-005634 PB-1CHOC12SMIR-QPP
FPC 2
PIC 0 REV 16 750-007141 PC-10GE-SFP
PIC 1 REV 06 750-015217 PC-8GE-TYPE3-SFP-IQ2
PIC 2 REV 05 750-004695 PC-TUNNEL
PIC 3 REV 17 750-009553 PC-4OC48-SON-SFP
FPC 3 REV 01 710-010154 T640-FPC3-E
PIC 0 REV 07 750-012793 PC-1XGE-TYPE3-XFP-IQ2
PIC 1 REV 25 750-007141 PC-10GE-SFP
PIC 2 REV 17 750-009553 PC-4OC48-SON-SFP
PIC 3 REV 32 750-003700 PC-1OC192-SON-VSR
FPC 4 REV 16 710-013037 T1600-FPC4-ES
PIC 1 REV 06 750-034781 PD-1CE-CFP
FPC 5 REV 02 710-013037 T1600-FPC4-ES
PIC 0 REV 16 750-012518 PD-4OC192-SON-XFP
PIC 1 REV 01 750-010850 PD-1OC768-SON-SR
FPC 6 REV 14 710-013037 T1600-FPC4-ES
PIC 0 REV 11 750-017405 PD-4XGE-XFP
PIC 1 REV 13 750-017405 PD-4XGE-XFP
FPC 7 REV 09 710-007529 T640-FPC3
PIC 0 REV 10 750-012793 PC-1XGE-TYPE3-XFP-IQ2
PIC 1 REV 01 750-015217 PC-8GE-TYPE3-SFP-IQ2
PIC 2 REV 01 750-015217 PC-8GE-TYPE3-SFP-IQ2
PIC 3 REV 15 750-009450 PC-1OC192-SON-SR2
SIB 0 REV 07 710-013074 SIB-I-T1600-S
SIB 1 REV 07 710-013074 SIB-I-T1600-S
SIB 2 REV 07 710-013074 SIB-I-T1600-S
SIB 3 REV 07 710-013074 SIB-I-T1600-S
SIB 4 REV 07 710-013074 SIB-I-T1600-S
Fan Tray 0 FANTRAY-T-S
Fan Tray 1 FANTRAY-T-S
Fan Tray 2 FAN-REAR-TX-T640-S
222 Copyright © 2018, Juniper Networks, Inc.
Chapter 25: Upgrading to a T4000 Router From a T640 or T1600 Router
2.
If two RE-DUO-C1800-8G Routing Engines are not installed, order and install
RE-DUO-C1800-8G Routing Engines.
Checking the Hardware Version of the Rear Fan Tray
The rear fan tray model number FAN-REAR-TXP-LCC has eight fans and is required to support the additional thermal power generation of the T4000 router.
The following fan trays do not provide sufficient cooling for the T4000 router:
• RHTREARTRAY-T
• FAN-REAR-TX-T640
• FAN-R
• FAN-REAR-T
To determine which version of the rear fan tray is installed:
1.
Issue the show chassis environment command:
In this example, the output shows that the rear fan tray has five blowers, indicating that the RHTREARTRAY-T rear fan tray is installed. The last five lines of the output for the fans each include Blower in the description.
user@host> show chassis environment
Fans Top Left Front fan OK Spinning at normal speed
Top Left Middle fan OK Spinning at normal speed
Top Left Rear fan OK Spinning at normal speed
Top Right Front fan OK Spinning at normal speed
Top Right Middle fan OK Spinning at normal speed
Top Right Rear fan OK Spinning at normal speed
Bottom Left Front fan OK Spinning at normal speed
Bottom Left Middle fan OK Spinning at normal speed
Bottom Left Rear fan OK Spinning at normal speed
Bottom Right Front fan OK Spinning at normal speed
Bottom Right Middle fan OK Spinning at normal speed
Bottom Right Rear fan OK Spinning at normal speed
Fourth Blower from top OK Spinning at normal speed
Bottom Blower OK Spinning at normal speed
Middle Blower OK Spinning at normal speed
Top Blower OK Spinning at normal speed
Second Blower from top OK Spinning at normal speed
In this example, the output shows that the rear fan tray has eight fans, indicating that
FAN-REAR-TX-T640-S rear fan tray is installed. The last eight lines of the output for the fans each begin with Rear Tray and include fan in the description.
Fans Top Left Front fan OK Spinning at normal speed
Top Left Middle fan OK Spinning at normal speed
Top Left Rear fan OK Spinning at normal speed
Top Right Front fan OK Spinning at normal speed
Top Right Middle fan OK Spinning at normal speed
Top Right Rear fan OK Spinning at normal speed
Bottom Left Front fan OK Spinning at normal speed
Bottom Left Middle fan OK Spinning at normal speed
Bottom Left Rear fan OK Spinning at normal speed
Copyright © 2018, Juniper Networks, Inc.
223
T4000 Core Router Hardware Guide
Bottom Right Front fan OK Spinning at normal speed
Bottom Right Middle fan OK Spinning at normal speed
Bottom Right Rear fan OK Spinning at normal speed
Rear Tray Top fan OK Spinning at normal speed
Rear Tray Second fan OK Spinning at normal speed
Rear Tray Third fan OK Spinning at normal speed
Rear Tray Fourth fan OK Spinning at normal speed
Rear Tray Fifth fan OK Spinning at normal speed
Rear Tray Sixth fan OK Spinning at normal speed
Rear Tray Seventh fan OK Spinning at normal speed
Rear Tray Bottom fan OK Spinning at normal speed
2.
Issue the show chassis hardware models command.
In this example, the output shows that FAN-REAR-TX-T640 is installed.
user@host> show chassis hardware models user@host> show chassis hardware models
Hardware inventory:
Item Version Part number FRU model number
Midplane REV 04 710-002726 CHAS-BP-T640-S
FPM Display REV 02 710-002897 CRAFT-T640-S
CIP REV 05 710-002895 CIP-L-T640-S
PEM 0 Rev 01 740-002595 PWR-T-DC-S
SCG 0 REV 04 710-003423 SCG-T-S
SCG 1 REV 04 710-003423 SCG-T-S
Routing Engine 0 REV 01 740-005022 RE-600-2048-S
Routing Engine 1 REV 07 740-005022 RE-600-2048-S
CB 0 REV 06 710-002726 CB-L-T-S
CB 1 REV 06 710-002728 CB-L-T-S
FPC 5 REV 05 710-007527 T640-FPC2
PIC 0 REV 05 750-002510 PB-2GE-SX
PIC 1 REV 05 750-001901 PB-4OC12-SON-SMIR
FPC 6 REV 03 710-001721 T640-FPC3
PIC 1 REV 01 750-009553 PC-4OC48-SON-SFP
SIB 4 REV 02 750-005486 SIB-I-T640-S
Fan Tray 0 FANTRAY-T-S
Fan Tray 1 FANTRAY-T-S
Fan Tray 2 FAN-REAR-TX-T640-S
3.
If the FAN-REAR-TXP-LCC rear fan tray is not installed, order and install the
FAN-REAR-TXP-LCC rear fan tray.
Checking the Hardware Version of the FPCs
The FPCs supported for the T4000 router are listed in
SIBs.
To determine which model numbers of FPCs are installed:
1.
Issue the show chassis hardware models command:
In this example, the output shows that the T640-FPC2 and T640-FPC3 FPCs are installed.
user@host> show chassis hardware models
224 Copyright © 2018, Juniper Networks, Inc.
Chapter 25: Upgrading to a T4000 Router From a T640 or T1600 Router user@host> show chassis hardware models
Hardware inventory:
Item Version Part number FRU model number
Midplane REV 04 710-002726 CHAS-BP-T640-S
FPM Display REV 02 710-002897 CRAFT-T640-S
CIP REV 05 710-002895 CIP-L-T640-S
PEM 0 Rev 01 740-002595 PWR-T-DC-S
SCG 0 REV 04 710-003423 SCG-T-S
SCG 1 REV 04 710-003423 SCG-T-S
Routing Engine 0 REV 01 740-005022 RE-600-2048-S
Routing Engine 1 REV 07 740-005022 RE-600-2048-S
CB 0 REV 06 710-002726 CB-L-T-S
CB 1 REV 06 710-002728 CB-L-T-S
FPC 5 REV 05 710-007527 T640-FPC2
PIC 0 REV 05 750-002510 PB-2GE-SX
PIC 1 REV 05 750-001901 PB-4OC12-SON-SMIR
FPC 6 REV 03 710-001721 T640-FPC3
PIC 1 REV 01 750-009553 PC-4OC48-SON-SFP
SIB 4 REV 02 750-005486 SIB-I-T640-S
Fan Tray 0 FANTRAY-T-S
Fan Tray 1 FANTRAY-T-S
Fan Tray 2 FAN-REAR-TX-T640-S
In this example, the output shows that T640-FPC2-E2 , T640-FPC1-E2 , T640-FPC3-E , and T1600-FPC4-ES FPCs are installed. The T1600-FPC4-ES FPCs are supported for the T4000 router. All other FPCs in the this example are currently unsupported for the T4000 router.
user@host> show chassis hardware models
Hardware inventory:
Item Version Part number FRU model number
Midplane REV 03 710-005608 CHAS-BP-T640-S
FPM Display REV 05 710-002897 CRAFT-T640-S
CIP REV 06 710-002895 CIP-L-T640-S
PEM 0 Rev 07 740-017906 PWR-T1600-3-80-DC-S
PEM 1 Rev 18 740-002595 PWR-T-DC-S
SCG 0 REV 15 710-003423 SCG-T-S
Routing Engine 0 REV 08 740-014082 RE-A-2000-4096-S
Routing Engine 1 REV 07 740-014082 RE-A-2000-4096-S
CB 0 REV 05 710-007655 CB-T-S
CB 1 REV 03 710-017707 CB-T-S
FPC 0 REV 07 710-013558 T640-FPC2-E2
PIC 0 REV 01 750-010618 PB-4GE-SFP
PIC 1 REV 06 750-001900 PB-1OC48-SON-SMSR
PIC 2 REV 14 750-001901 PB-4OC12-SON-SMIR
PIC 3 REV 07 750-001900 PB-1OC48-SON-SMSR
FPC 1 REV 06 710-013553 T640-FPC1-E2
PIC 0 REV 08 750-001072 P-1GE-SX
PIC 1 REV 10 750-012266 PB-4GE-TYPE1-SFP-IQ2
PIC 2 REV 22 750-005634 PB-1CHOC12SMIR-QPP
FPC 2
PIC 0 REV 16 750-007141 PC-10GE-SFP
PIC 1 REV 06 750-015217 PC-8GE-TYPE3-SFP-IQ2
PIC 2 REV 05 750-004695 PC-TUNNEL
PIC 3 REV 17 750-009553 PC-4OC48-SON-SFP
FPC 3 REV 01 710-010154 T640-FPC3-E
Copyright © 2018, Juniper Networks, Inc.
225
T4000 Core Router Hardware Guide
PIC 0 REV 07 750-012793 PC-1XGE-TYPE3-XFP-IQ2
PIC 1 REV 25 750-007141 PC-10GE-SFP
PIC 2 REV 17 750-009553 PC-4OC48-SON-SFP
PIC 3 REV 32 750-003700 PC-1OC192-SON-VSR
FPC 4 REV 16 710-013037 T1600-FPC4-ES
PIC 1 REV 06 750-034781 PD-1CE-CFP
FPC 5 REV 02 710-013037 T1600-FPC4-ES
PIC 0 REV 16 750-012518 PD-4OC192-SON-XFP
PIC 1 REV 01 750-010850 PD-1OC768-SON-SR
FPC 6 REV 14 710-013037 T1600-FPC4-ES
PIC 0 REV 11 750-017405 PD-4XGE-XFP
PIC 1 REV 13 750-017405 PD-4XGE-XFP
FPC 7 REV 09 710-007529 T640-FPC3
PIC 0 REV 10 750-012793 PC-1XGE-TYPE3-XFP-IQ2
PIC 1 REV 01 750-015217 PC-8GE-TYPE3-SFP-IQ2
PIC 2 REV 01 750-015217 PC-8GE-TYPE3-SFP-IQ2
PIC 3 REV 15 750-009450 PC-1OC192-SON-SR2
SIB 0 REV 07 710-013074 SIB-I-T1600-S
SIB 1 REV 07 710-013074 SIB-I-T1600-S
SIB 2 REV 07 710-013074 SIB-I-T1600-S
SIB 3 REV 07 710-013074 SIB-I-T1600-S
SIB 4 REV 07 710-013074 SIB-I-T1600-S
Fan Tray 0 FANTRAY-T-S
Fan Tray 1 FANTRAY-T-S
Fan Tray 2 FAN-REAR-TX-T640-S
2.
Remove all unsupported FPCs. To minimize downtime, you can upgrade FPCs that are supported on both the T640 router or T1600 router and the T4000 router before the upgrade to a T4000 router.
NOTE: The following FPCs cannot be installed until all other hardware components for the T4000 router have been installed.
• T1600-FPC4-ES FPCs cannot be installed on T640 routers that have not been upgraded. The T1600-FPC4-ES FPC is not supported on T640 routers.
• T4000-FPC5-3D FPCs cannot be installed on T640 or T1600 routers that have not been upgraded.
Related
Documentation
•
Overview of Upgrading to a T4000 Router on page 227
•
226 Copyright © 2018, Juniper Networks, Inc.
Chapter 25: Upgrading to a T4000 Router From a T640 or T1600 Router
T4000 Upgrade Kit
The following hardware components are required for an upgrade from a Juniper Networks
T640 Core Router or T1600 Core Router to a T4000 Core Router.
• Two redundant, load-sharing six-input DC power supplies (PWR-T-6-60-DC)
• Five T4000 SIBs (SIB-I-T4000)
• One T Series craft interface panel (CRAFT-T-SERIES)
• Two front fan trays (FANTRAY-T4000)
• One rear fan tray (FAN-REAR-TXP-LCC)
• Two Routing Engines (RE-DUO-C1800-8G)
NOTE: RE-DUO-C1800-16G is also supported
• Two control boards (CB-LCC)
You can order these components individually or order a T4000 upgrade kit that contains all the components. You might need additional DC power cables.
NOTE: These components must be installed before you can install a T4000
FPC5 in the T4000 router.
Related
Documentation
•
Checking the Hardware Version of T640 or T1600 Components on page 218
•
Overview of Upgrading to a T4000 Router on page 227
Overview of Upgrading to a T4000 Router
To upgrade to a T4000 Router:
1.
Verify that you have prepared the T640 or T1600 router for the upgrade. See
“Overview of Preparing to Upgrade to a T4000 Router” on page 217 .
2.
Verify that you have all the hardware required to upgrade to a T4000 router. See the following documentation:
•
•
Checking the Hardware Version of T640 or T1600 Components on page 218
3.
Upgrade the hardware components on the T640 or T1600 router. See
Hardware Components on the T640 or T1600 Router” on page 228 .
4.
Upgrade the SIBs using one of the following procedures:
Copyright © 2018, Juniper Networks, Inc.
227
T4000 Core Router Hardware Guide
• For the Junos OS Release 12.1, see
“Upgrading to T4000 SIBs with Junos OS Release
.
• For the Junos OS Release 12.2 and later, see
“Upgrading to T4000 SIBs Online with
Junos OS Release 12.2 and Later” on page 233 .
5.
For Junos OS Release 12.3 and later, configure power management, if needed. See the following documentation:
•
Configuring DC Power on a T4000 Router on page 213
•
T4000 Power Management (Three 80-A Cables on a Six-Input DC Power Supply) on page 103
•
T4000 Power Management (Four 60-A Cables on a Six-Input DC Power Supply) on page 103
6.
After the SIBs have been upgraded and power management has been configured, you can install the T4000 FPCs. See
“Installing the T4000 FPCs After an Upgrade from a T640 or T1600 Router” on page 235
.
7.
Register your upgrade. See
“Registering Your T4000 Upgrade” on page 236 .
Related
Documentation
•
T4000 Router Description on page 3
Upgrading Hardware Components on the T640 or T1600 Router
The following components are supported on the T640 and T1600 router, and can be installed without powering off or rebooting the router.
You must proceed through the upgrade process in the following order:
1.
Preparing to Upgrade the T640 or T1600 Components on page 228
2.
Upgrade to the Six-Input DC Power Supplies on page 229
3.
Upgrade the Fan Trays on page 229
4.
Upgrading the Host Subsystem on page 230
5.
Removing Unsupported FPCs and PICs on page 230
6.
Verify That Components Supported by the T4000 Router Are Installed on page 231
Preparing to Upgrade the T640 or T1600 Components
1.
Unpack the upgrade components and verify the parts received.
2.
Gather the tools required to upgrade the T4000 router hardware components.
228 Copyright © 2018, Juniper Networks, Inc.
Chapter 25: Upgrading to a T4000 Router From a T640 or T1600 Router
Upgrade to the Six-Input DC Power Supplies
To upgrade to the six-input DC power supply:
NOTE: This procedure does not apply to T640 or T1600 routers with AC power supplies. In that case, both AC power supplies must be powered off and removed before the DC power supplies are installed.
1.
Verify that the number of inputs that you plan to connect to the 6-input DC power supply provides sufficient power for your planned configuration for the T4000 router.
NOTE: For the Junos OS Release 12.1 and 12.2, a minimum of five inputs for each power supply is required. Connecting only four inputs to each DC power supply in a T4000 router is not currently supported.
2.
Remove one of the existing power supplies. For information about removing T640 or
T1600 components, see the T640 Core Router Hardware Guide or T1600 Core Router
Hardware Guide .
3.
Install one six-input DC power supply.
4.
Connect the DC power cables to the six-input DC power supply.
5.
Repeat the procedure for the other power supply.
Upgrade the Fan Trays
To upgrade the fan trays:
1.
Upgrade the front fan trays.
2.
Upgrade the rear fan tray, if needed. FAN-REAR-TXP-LCC rear fan tray is required.
Install the FAN-REAR-TXP-LCC rear fan tray, if not already installed.
Copyright © 2018, Juniper Networks, Inc.
229
T4000 Core Router Hardware Guide
Upgrading the Host Subsystem
Upgrade the host subsystem, if needed. For information about upgrading the host subsystem, see the hardware guide for the T640 or T1600 router:
• T640 Core Router Hardware Guide
• T1600 Core Router Hardware Guide
NOTE: Upgrading a Routing Engine or Control board requires that the host subsystem be taken offline. Upgrade the backup Routing Engine and control board first, bring them online, then upgrade the other Routing Engine and control board.
1.
Take the host subsystem offline.
2.
Upgrade the backup Routing Engine.
3.
Upgrade the backup control board.
4.
Verify that the two configuration switches on the faceplate of the LCC-CB are set correctly for a standalone T4000 router:
• The M/S configuration switch must be set to S .
• The CHASSIS ID configuration switch must be set to 0 .
5.
Take the other host subsystem offline.
6.
Repeat the procedure for the other Routing Engine and control board.
Removing Unsupported FPCs and PICs
NOTE: Although you can choose to leave unsupported FPCs and PICs in the
T640 or T1600 router, the FPCs and PICs installed in those FPCs will not come online in the T4000 router, and will not function.
To remove unsupported PICs and FPCs from the T640 or T1600 router:
1.
Determine the FPCs supported by the T4000 router for your Junos OS Release. For a list of the FPCs supported by the T4000 router, see
“T4000 FPCs Supported” on page 61
.
2.
Remove FPCs not supported by the T4000 router. . Install blanks in the FPC slots.
230 Copyright © 2018, Juniper Networks, Inc.
Chapter 25: Upgrading to a T4000 Router From a T640 or T1600 Router
3.
Determine the PICs supported by the T4000 router for your Junos OS Release. For a list of PICs supported by the T4000 router, see the T4000 Core Router Interface Module
Reference .
4.
Remove PICs not supported by the T4000 router.
Verify That Components Supported by the T4000 Router Are Installed
To verify that the hardware components supported by the T4000 router are installed on the T640 or T1600 router:
1.
Issue the show chassis hardware models command: user@host> show chassis hardware models
Hardware inventory:
Item Version Part number Serial number FRU model number
Midplane REV 01 710-027486 RC9244 CHAS-BP-T1600-S
FPM Display REV 03 710-021387 BBAF4338 CRAFT-T1600-S
CIP REV 06 710-002895 BBAF2353 CIP-L-T640-S
PEM 0 REV 02 740-036442 VG00017 PWR-T-6-60-DC-S
PEM 1 REV 02 740-036442 VG00017 PWR-T-6-60-DC-S
SCG 0 REV 18 710-003423 BBAE4908 SCG-T-S
SCG 1 REV 18 710-003423 BBAB2590 SCG-T-S
Routing Engine 0 REV 06 740-026941 P737F-002693 RE-DUO-C1800-8G-S
Routing Engine 1 REV 06 740-026941 P737F-002587 RE-DUO-C1800-8G-S
CB 0 REV 09 710-022597 EF6057 CB-LCC-S
CB 1 REV 09 710-022597 EF9180 CB-LCC-S
FPC 5 REV 03 710-033871 IPUCAMBCTD T1600-FPC4-ES
PIC 1 REV 03 750-034781 IPUIBKLMAA PD-1CE-CFP-FPC4
SIB 0 REV 02 750-005486 SIB-I-T640-S
SIB 1 REV 02 750-005486 SIB-I-T640-S
SIB 2 REV 02 750-005486 SIB-I-T640-S
SIB 3 REV 02 750-005486 SIB-I-T640-S
SIB 4 REV 02 750-005486 SIB-I-T640-S
Fan Tray 0 FANTRAY-T4000-S
Fan Tray 1 FANTRAY-T4000-S
Fan Tray 2 FAN-REAR-TXP-LCC-S
2.
Verify that the following hardware components have been installed:
• Two PWR-T-6-60-DC
• Two RE-DUO-C1800-8G or two RE-DUO-C1800-16G
• Two CB-LCC
• Two FANTRAY-T4000
• One FAN-REAR-TXP-LCC
3.
Verify that unsupported PICs and FPCs have been removed. See the following documentation:
• For a list of the FPCs supported by the T4000 router, see
“T4000 FPCs Supported” on page 61 .
Copyright © 2018, Juniper Networks, Inc.
231
T4000 Core Router Hardware Guide
• For a list of PICs supported by the T4000 router, see the T4000 Core Router Interface
Module Reference .
Upgrading to T4000 SIBs with Junos OS Release 12.1
NOTE: You must use this procedure for Junos OS Release 12.1.
You must proceed through the upgrade process in the following order:
1.
Unpack the T4000 SIBs and verify the parts received.
2.
Gather the tools required to upgrade the T4000 SIBs.
3.
Include the fabric upgrade-mode statement in the configuration of the T640 or T1600 router at the [edit chassis] hierarchy level.
[edit] user@host# set chassis fabric upgrade-mode
4.
Commit the configuration on both the master and the backup Routing Engines.
[edit] user@host# commit synchronize
5.
On the T640 router or the T1600 router, verify that upgrade mode has been set.
[edit] user@host# show chassis fabric upgrade-mode
6.
Install the SIB-I-T4000 SIBs. Replace one SIB at a time.
After each SIB is replaced, bring the newly installed SIB online, and check for crc errors and link status with the following commands before adding another SIB:
• Use the show chassis sib command to check the SIB state. The state should be
Online , indicating that the SIB is operational and running.
• Use the show chassis fabric fpc to check the switch fabric links between the Flexible
PIC Concentrators (FPCs) and the switch interface boards (SIBs). The Fabric management FPC state should be Links ok . The Link error state indicates that the link between the SIB and FPC has CRC errors. However, the link is still eligible to carry traffic.
• Use the show chassis fabric sib to check the switch fabric links between the SIBs and FPCs. The Fabric management SIB state should be Links ok . The Link error state indicates that the link between the SIB and the FPC is not operational.
7.
Delete the fabric upgrade-mode statement in the configuration of the T4000 router at the [edit chassis] hierarchy level.
232 Copyright © 2018, Juniper Networks, Inc.
Chapter 25: Upgrading to a T4000 Router From a T640 or T1600 Router
[edit] user@host# delete chassis fabric upgrade-mode
8.
Commit the configuration on both the master and the backup Routing Engines.
[edit] user@host# commit synchronize
9.
Power off the T1600 router or T640 router.
See the T640 Core Router Hardware Guide or T1600 Core Router Hardware Guide .
10.
Power on the T4000 router.
See
“Powering On the T4000 Router” on page 207
.
11.
Issue the show chassis hardware models command: user@host> show chassis hardware models
Hardware inventory:
Item Version Part number Serial number FRU model number
Midplane REV 01 710-027486 RC9244 CHAS-BP-T1600-S
FPM Display REV 03 710-021387 BBAF4338 CRAFT-T1600-S
CIP REV 06 710-002895 BBAF2353 CIP-L-T640-S
PEM 0 REV 02 740-036442 VG00017 PWR-T-6-60-DC-S
PEM 1 REV 02 740-036442 VG00017 PWR-T-6-60-DC-S
SCG 0 REV 18 710-003423 BBAE4908 SCG-T-S
SCG 1 REV 18 710-003423 BBAB2590 SCG-T-S
Routing Engine 0 REV 06 740-026941 P737F-002693 RE-DUO-C1800-8G-S
Routing Engine 1 REV 06 740-026941 P737F-002587 RE-DUO-C1800-8G-S
CB 0 REV 09 710-022597 EF6057 CB-LCC-S
CB 1 REV 09 710-022597 EF9180 CB-LCC-S
SIB 0 REV 02 711-036340 EE6290
SIB 1 REV 02 711-036340 EE6290
SIB 2 REV 02 711-036340 EE6290
SIB 3 REV 02 711-036340 EE6290
SIB 4 REV 02 711-036340 EE6290
Fan Tray 0 FANTRAY-T4000-S
Fan Tray 1 FANTRAY-T4000-S
Fan Tray 2 FAN-REAR-TXP-LCC-S
Related
Documentation
•
•
Checking the Hardware Version of T640 or T1600 Components on page 218
Upgrading to T4000 SIBs Online with Junos OS Release 12.2 and Later
NOTE: This procedure requires 64-bit Junos OS Release 12.2 and later.
Copyright © 2018, Juniper Networks, Inc.
233
T4000 Core Router Hardware Guide
You must proceed through the upgrade process in the following order:
1.
Unpack the T4000 SIBs and verify the parts received.
2.
Gather the tools required to upgrade the T4000 SIBs.
3.
Verify that both Routing Engines in the T640 or T1600 router are running a 64-bit
Junos Release 12.2 and later.
user@host> show version
Hostname: host
Hostname: quietriot1
Model: t1600
JUNOS Base OS boot [12.2R1.1]
JUNOS Base OS Software Suite [12.2R1.1]
JUNOS 64-bit Kernel Software Suite [12.2R1.1]
...
4.
Include the fabric upgrade-mode statement in the configuration of the T640 or T1600 router at the [edit chassis] hierarchy level.
[edit] user@host# set chassis fabric upgrade-mode T4000
5.
Commit the configuration on both the master and the backup Routing Engines.
[edit] user@host# commit synchronize
6.
On the T640 router or the T1600 router, verify that upgrade mode has been set.
[edit] user@host# show chassis fabric upgrade-mode
7.
Install the SIB-I-T4000 SIBs. Replace one SIB at a time.
After each SIB is replaced, bring the newly installed SIB online, and check for crc errors and link status with the following commands before adding another SIB:
• Use the show chassis sib to check the SIB state. The state should be Online , indicating that the SIB is operational and running.
• Use the show chassis fabric fpc to check the switch fabric links between the Flexible
PIC Concentrators (FPCs) and the switch interface boards (SIBs). The Fabric management FPC state should be Links ok . The Link error state indicates that the link between the SIB and FPC has CRC errors. However, the link is still eligible to carry traffic.
• Use the show chassis fabric sib to check the switch fabric links between the SIBs and FPCs. The Fabric management SIB state should be Links ok . The Link error state indicates that the link between the SIB and the FPC is not operational.
234 Copyright © 2018, Juniper Networks, Inc.
Chapter 25: Upgrading to a T4000 Router From a T640 or T1600 Router
8.
Delete the fabric upgrade-mode T4000 statement in the configuration of the T4000 router at the [edit chassis] hierarchy level.
[edit] user@host# delete chassis fabric upgrade-mode T4000
9.
Commit the configuration on both the master and the backup Routing Engines.
[edit] user@host# commit synchronize
10.
Issue the show chassis hardware models command: user@host> show chassis hardware models
Hardware inventory:
Item Version Part number Serial number FRU model number
Midplane REV 01 710-027486 RC9244 CHAS-BP-T1600-S
FPM Display REV 03 710-021387 BBAF4338 CRAFT-T1600-S
CIP REV 06 710-002895 BBAF2353 CIP-L-T640-S
PEM 0 REV 02 740-036442 VG00017 PWR-T-6-60-DC-S
PEM 1 REV 02 740-036442 VG00017 PWR-T-6-60-DC-S
SCG 0 REV 18 710-003423 BBAE4908 SCG-T-S
SCG 1 REV 18 710-003423 BBAB2590 SCG-T-S
Routing Engine 0 REV 06 740-026941 P737F-002693 RE-DUO-C1800-8G-S
Routing Engine 1 REV 06 740-026941 P737F-002587 RE-DUO-C1800-8G-S
CB 0 REV 09 710-022597 EF6057 CB-LCC-S
CB 1 REV 09 710-022597 EF9180 CB-LCC-S
SIB 0 REV 02 711-036340 EE6290
SIB 1 REV 02 711-036340 EE6290
SIB 2 REV 02 711-036340 EE6290
SIB 3 REV 02 711-036340 EE6290
SIB 4 REV 02 711-036340 EE6290
Fan Tray 0 FANTRAY-T4000-S
Fan Tray 1 FANTRAY-T4000-S
Fan Tray 2 FAN-REAR-TXP-LCC-S
Related
Documentation
•
•
Checking the Hardware Version of T640 or T1600 Components on page 218
Installing the T4000 FPCs After an Upgrade from a T640 or T1600 Router
After the SIBs have been upgraded, you can install Type 5 FPCs and PICs.
1.
Install the Type 5 FPCs (T4000 FPC5).
See
“Installing a T4000 FPC” on page 298
2.
Install Type 5 PICs.
See
“Installing a T4000 PIC” on page 303
.
Copyright © 2018, Juniper Networks, Inc.
235
T4000 Core Router Hardware Guide
Related
Documentation
•
T4000 FPC Description on page 57
•
T4000 PIC Description on page 62
•
Overview of Upgrading to a T4000 Router on page 227
Registering Your T4000 Upgrade
You must register the upgrade with Juniper Networks upon completion of the upgrade.
To register your upgrade:
1.
Log on to the Juniper Networks Customer Support Center at https://www.juniper.net/customers/support/ .
2.
Click on Update Install Base .
3.
Follow the instructions provided in this link.
After your upgrade is registered, allow up to 45 days for restocking of the new hardware configuration to support any Next Day or Same Day contracts. Juniper Networks will provide Best Effort support until restocking of the upgraded product is complete.
Related
Documentation
•
Overview of Upgrading to a T4000 Router on page 227
236 Copyright © 2018, Juniper Networks, Inc.
PART 4
Installing and Replacing Components
•
Overview of Installing and Replacing Components on page 239
•
Replacing Chassis Components on page 245
•
Replacing Cooling System Components on page 259
•
Replacing Host Subsystem Components on page 273
•
Replacing Line Card Components on page 295
•
Replacing Power System Components on page 307
•
Replacing Switch Fabric Components on page 319
Copyright © 2018, Juniper Networks, Inc.
237
T4000 Core Router Hardware Guide
238 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 26
Overview of Installing and Replacing
Components
•
T4000 Field-Replaceable Units on page 239
•
Tools and Parts Required for Replacing T4000 Hardware Components on page 241
T4000 Field-Replaceable Units
Field-replaceable units (FRUs) are router components that can be replaced at the customer site. Replacing most FRUs requires minimal router downtime.
• Hot-removable and hot-insertable FRUs—You can remove and replace these components without powering off the router or disrupting the routing functions.
• Hot-pluggable FRUs—You can remove and replace these components without powering down the router, but the routing functions of the system are interrupted when the component is removed.
• Other FRUs require that you power off the router or backup Routing Engine.
NOTE: Before you remove a Control Board or Routing Engine, you must take the host subsystem offline.
lists the replaceable FRUs for the router.
Table 77: Field-Replaceable Units
Component
Effect of
Replacement For More Information
Air filters Hot-removable and hot-insertable
“Replacing a T4000 Front Air Filter” on page 259
“Replacing a T4000 Rear Air Filter” on page 261
“Replacing a T4000 Six-Input DC Power Supply
“Replacing a T4000 Six-Input DC Power Supply Side
Copyright © 2018, Juniper Networks, Inc.
239
T4000 Core Router Hardware Guide
Table 77: Field-Replaceable Units (continued)
Component
Effect of
Replacement
Connector Interface Panel (CIP) Hot-pluggable
Backup Control Board
Master Control Board (if nonstop active routing is configured)
Hot-removable and hot-insertable
For More Information
“Replacing a T4000 CIP” on page 245
“Taking the T4000 Host Subsystem Offline” on page 273
“Replacing a T4000 LCC-CB” on page 275
Nonredundant Control Boards
Master Control Board (if nonstop active routing is not configured)
Hot-pluggable
Craft Interface
Front and rear fan trays
Hot-removable and hot-insertable
Hot-removable and hot-insertable
“Taking the T4000 Host Subsystem Offline” on page 273
“Replacing a T4000 LCC-CB” on page 275
“Replacing a T4000 Craft Interface” on page 249
Flexible PIC Concentrators (FPCs)
“Replacing a T4000 Lower Front Fan Tray” on page 265
“Replacing a T4000 Upper Front Fan Tray” on page 267
“Replacing a T4000 Rear Fan Tray” on page 269
“Replacing a T4000 FPC” on page 295
PICs
Redundant power supplies
Hot-removable and hot-insertable
Hot-removable and hot-insertable
Hot-removable and hot-insertable
“Replacing a T4000 PIC” on page 301
“Replacing a T4000 Six-Input DC Power Supply” on page 307
“Replacing a T4000 DC Power Supply Cable” on page 315
Nonredundant power supplies The router must be powered off before replacement.
Nonredundant Routing Engine
Master Routing Engine (if nonstop active routing is not configured)
Hot-pluggable
Backup Routing Engine
Master Routing Engine (if nonstop active routing is configured)
Hot-removable and
Hot-insertable
“Replacing a T4000 Six-Input DC Power Supply” on page 307
“Replacing a T4000 DC Power Supply Cable” on page 315
“Taking the T4000 Host Subsystem Offline” on page 273
“Replacing a T4000 Routing Engine” on page 280
“Taking the T4000 Host Subsystem Offline” on page 273
“Replacing a T4000 Routing Engine” on page 280
240 Copyright © 2018, Juniper Networks, Inc.
Chapter 26: Overview of Installing and Replacing Components
Table 77: Field-Replaceable Units (continued)
Component
Effect of
Replacement
DIMM Module in a Routing Engine
CompactFlash card and SSD in a Routing
Engine
For More Information
The Routing Engine is removed.
“Replacing a DIMM Module in a T4000 RE-C1800
Power off the Routing
Engine.
“Replacing a CompactFlash Card in a T4000
RE-C1800 Routing Engine” on page 286
“Replacing a Solid-State Disk in a T4000 RE-C1800
Backup SONET Clock Generator (SCG)
Master SONET Clock Generator (SCG)
Nonredundant SONET Clock Generator (SCG)
Hot-pluggable
Switch Interface Boards (SIBs)
Hot-removable and hot-insertable
Hot-removable and hot-insertable
“Replacing a T4000 SCG” on page 256
“Replacing a T4000 SCG” on page 256
“Replacing a T4000-SIB” on page 319
“Replacing a T4000 TXP-LCC-3D SIB” on page 322
Related
Documentation
•
T4000 Hardware Component Overview on page 5
•
T4000 Component Redundancy on page 7
•
Tools and Parts Required for Replacing T4000 Hardware Components on page 241
Tools and Parts Required for Replacing T4000 Hardware Components
To replace hardware components, you need the tools and parts listed in
Table 78: Tools and Parts Required for Component Replacement
Components Tool or part
All Electrostatic discharge (ESD) grounding wrist strap
Air filter (front or rear)
CIP
Craft interface
Control board
Phillips (+) screwdrivers, numbers 1 and 2
Phillips (+) screwdrivers, numbers 1 and 2
Phillips (+) screwdrivers, numbers 1 and 2
Phillips (+) screwdrivers, numbers 1 and 2
Electrostatic bag or antistatic mat
Blank panel (if component is not reinstalled)
Copyright © 2018, Juniper Networks, Inc.
241
T4000 Core Router Hardware Guide
242
Table 78: Tools and Parts Required for Component Replacement (continued)
Components Tool or part
DC power supply
DC power supply cable
Fan tray (front or rear)
FPC
PIC
Routing Engine
Phillips (+) screwdrivers, numbers 1 and 2
7/16-in. (11 mm) nut driver
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts.
Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 in-lb (5.0 Nm).
7/16-in. (11 mm) nut driver
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts.
Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 in-lb (5.0 Nm).
Phillips (+) screwdrivers, numbers 1 and 2
Phillips (+) screwdrivers, numbers 1 and 2
Blank panel (if component is not reinstalled)
Electrostatic bag or antistatic mat
Phillips (+) screwdrivers, numbers 1 and 2
Rubber safety cap for fiber-optic PICs or fiber-optic PIC cables
Flat-blade (–) screwdriver for Type 1 PICs
Electrostatic bag or antistatic mat
Blank panel (if component is not reinstalled)
Phillips (+) screwdrivers, numbers 1 and 2
Electrostatic bag or antistatic mat
Blank panel (if component is not reinstalled)
Serial cable to AUXILIARY or CONSOLE Routing
Engine port
Flat-blade (–) screwdriver
SIB Phillips (+) screwdrivers, numbers 1 and 2
Electrostatic bag or antistatic mat
Blank panel (if component is not reinstalled)
SCG Phillips (+) screwdrivers, numbers 1 and 2
Copyright © 2018, Juniper Networks, Inc.
Chapter 26: Overview of Installing and Replacing Components
Related
Documentation
•
Returning a Hardware Component to Juniper Networks, Inc. on page 387
•
Tools and Parts Required to Remove Components from a T4000 Router on page 388
Copyright © 2018, Juniper Networks, Inc.
243
T4000 Core Router Hardware Guide
244 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 27
Replacing Chassis Components
•
Replacing a T4000 CIP on page 245
•
Replacing a T4000 Craft Interface on page 249
•
Replacing a T4000 Console or Auxiliary Cable on page 250
•
Replacing a T4000 Management Ethernet Cable on page 253
•
Replacing the T4000 Alarm Relay Wires on page 255
•
Replacing a T4000 SCG on page 256
Replacing a T4000 CIP
The CIP is located to the left side of the FPC card cage. It houses the Routing Engine interface ports, which accept connections to external management and alarm-reporting devices.
The CIP is hot-pluggable. It weighs approximately 8 lb (3.6 kg). When the CIP is removed, you cannot control or communicate with the router using an external device.
1.
Removing a T4000 CIP on page 245
2.
Installing a T4000 CIP on page 246
Removing a T4000 CIP
To remove the CIP (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the site ESD points on the chassis.
2.
Disconnect any external devices connected to the CIP.
3.
Loosen the captive screws at the top and bottom of the CIP faceplate.
4.
Grasp the handle on the CIP faceplate and carefully pull the CIP straight out of the chassis.
Copyright © 2018, Juniper Networks, Inc.
245
T4000 Core Router Hardware Guide
CAUTION: Be sure to slide the CIP straight within the slot to avoid damaging the connector pins on the front of the midplane.
Figure 87: Removing the CIP
Installing a T4000 CIP
To install the CIP (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the CIP handle with one hand and hold the bottom edge of the CIP with the other hand to support its weight.
246 Copyright © 2018, Juniper Networks, Inc.
Chapter 27: Replacing Chassis Components
NOTE: The components on the CIP are on the left side of the board, unlike the components of an FPC, which are on the right side. Verify that the components are on the left before inserting the CIP.
3.
Insert the CIP into the leftmost slot of the FPC card cage, carefully aligning the top and bottom of the CIP with the guides in the card cage.
4.
Carefully push the CIP straight into the chassis until it contacts the midplane.
5.
Tighten the screws at the top and bottom of the CIP faceplate.
6.
Reattach any external devices connected to the CIP.
CAUTION: Be sure to slide the CIP straight within the slot to avoid damaging the connector pins on the front of the midplane.
7.
To verify that the CIP is installed correctly, plug an Ethernet cable into the Ethernet port on the CIP. If the host module is operational, the ACTIVE LED blinks to indicate
Ethernet activity. If you can run the CLI, the CIP is installed correctly.
Copyright © 2018, Juniper Networks, Inc.
247
T4000 Core Router Hardware Guide
Figure 88: Installing the CIP
248
See Also •
•
•
Related
Documentation
•
T4000 Connector Interface Panel (CIP) Description on page 14
•
Replacing the T4000 Alarm Relay Wires on page 255
•
Replacing a T4000 Console or Auxiliary Cable on page 250
•
Replacing a T4000 Management Ethernet Cable on page 253
Copyright © 2018, Juniper Networks, Inc.
Chapter 27: Replacing Chassis Components
Replacing a T4000 Craft Interface
1.
Removing the T4000 Craft Interface on page 249
2.
Installing the T4000 Craft Interface on page 250
Removing the T4000 Craft Interface
CAUTION: Before you remove the craft interface, remove the upper front fan tray. See
“Replacing a T4000 Upper Front Fan Tray” on page 267 .
To remove the craft interface, see
.
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Completely loosen the screws at the four corners of the craft interface.
3.
Insert the blade of a flat-blade screwdriver into the slot on one side of the craft interface, then gently pry that side out from the chassis.
4.
Insert the blade of a flat-blade screwdriver into the slot on the other side of the craft interface, then gently pry that side out from the chassis.
5.
Grasp the craft interface by the top and bottom edges and carefully pull it straight out of the chassis.
Figure 89: Removing the Craft Interface
T Series
FAIL
FPC0
OK
FAIL
ACO/LT
FPC1
OK
MENU
ENTER
FAIL
FPC2
OK
FAIL
FPC3
OK
FAIL
FPC4
OK
FAIL
FPC5
OK
FAIL OK
MASTER
HOST0
FAIL OK
HOST1
MASTER
SIB0
FAIL
OK
SIB1
SIB2
SIB3
SIB4
FAIL
FPC6
OK
FAIL
FPC7
OK
Copyright © 2018, Juniper Networks, Inc.
249
T4000 Core Router Hardware Guide
Installing the T4000 Craft Interface
To install the craft interface (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasping the craft interface by the top and bottom edges, press it into place.
3.
Tighten the screws at the corners of the craft interface.
NOTE: When you install the craft interface in an operating router, allow several minutes for the LEDs on the craft interface to reflect the current state of the router.
After you install the replacement craft interface, immediately reinstall the upper front fan tray. See
“Replacing a T4000 Upper Front Fan Tray” on page 267 .
Figure 90: Installing a Replacement Craft Interface
T Series
FAIL
FPC0
OK
FAIL
ACO/LT
FPC1
OK
MENU
ENTER
FAIL
FANTRAY-T4000
FAIL
FPC3
OK
FAIL FPC4
OK
FAIL
FPC5
OK
FAIL
OK MASTER
HOST0
FAIL OK
HOST1
MASTER
SIB0
FAIL
SIB1
SIB2
SIB3
SIB4
OK
FAIL
FPC6
OK
FAIL FPC7
OK
Related
Documentation
•
T4000 Craft Interface Description on page 16
•
Troubleshooting the T4000 Craft Interface on page 349
Replacing a T4000 Console or Auxiliary Cable
1.
Removing a T4000 Console or Auxiliary Cable on page 251
2.
Installing a T4000 Console or Auxiliary Cable on page 253
250 Copyright © 2018, Juniper Networks, Inc.
Chapter 27: Replacing Chassis Components
Removing a T4000 Console or Auxiliary Cable
To remove a serial cable connected to a management console or auxiliary device (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the site ESD points on the chassis.
2.
Turn off the power to the console or auxiliary device.
3.
Unscrew the screws that secure the cable connector to the port, using a 2.5-mm flat-blade screwdriver if necessary.
4.
Pull the cable connector straight out of the port.
5.
Disconnect the cable from the console or auxiliary device.
Copyright © 2018, Juniper Networks, Inc.
251
T4000 Core Router Hardware Guide
Figure 91: DB-9 Port on the CIP
HOST
0
ETHERNET
ACT 0
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
HOST
1
ETHERNET
ACT 1
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
RED ALARM
NC
C
NO
NC
C
NO
YELLOW
ALARM
See Also •
T4000 Connector Interface Panel (CIP) Description on page 14
•
Connecting the T4000 Router to a Management Console or Auxiliary Device on page 178
•
T4000 Routing Engine Interface Cable Specifications on page 113
•
DB-9 Connector Pinouts for the Routing Engine AUXILIARY and CONSOLE Ports on page 114
252 Copyright © 2018, Juniper Networks, Inc.
Chapter 27: Replacing Chassis Components
Installing a T4000 Console or Auxiliary Cable
The AUXILIARY port and CONSOLE port on the CIP both accept an RS-232 (EIA-232_ serial cable with DB-9 connectors.
To connect a management console or auxiliary device:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the site ESD points on the chassis.
2.
Connect one end of the replacement cable into the appropriate CONSOLE or AUXILIARY port. The ports labeled HOST 0 connect to the Routing Engine in the upper Routing
Engine slot ( RE0 ), and the ports labeled HOST 1 connect to the Routing Engine in the lower Routing Engine slot ( RE1 ).
3.
Using a 2.5-mm flat-blade screwdriver, tighten the screws on the connector.
4.
Plug the other end of the cable into the device's serial port.
See Also •
T4000 Connector Interface Panel (CIP) Description on page 14
•
Connecting the T4000 Router to a Management Console or Auxiliary Device on page 178
•
T4000 Routing Engine Interface Cable Specifications on page 113
•
DB-9 Connector Pinouts for the Routing Engine AUXILIARY and CONSOLE Ports on page 114
Related
Documentation
•
T4000 Connector Interface Panel (CIP) Description on page 14
•
Connecting the T4000 Router to a Management Console or Auxiliary Device on page 178
•
T4000 Routing Engine Interface Cable Specifications on page 113
•
DB-9 Connector Pinouts for the Routing Engine AUXILIARY and CONSOLE Ports on page 114
Replacing a T4000 Management Ethernet Cable
1.
Removing a T4000 Management Ethernet Cable on page 253
2.
Installing a T4000 Management Ethernet Cable on page 255
Removing a T4000 Management Ethernet Cable
1.
Press the tab on the connector, and pull the connector straight out of the ETHERNET port.
shows the connector.
2.
Disconnect the cable from the network device.
Copyright © 2018, Juniper Networks, Inc.
253
T4000 Core Router Hardware Guide
Figure 92: Ethernet Cable Connectors
Figure 93: Ethernet Port on CIP
HOST
0
ETHERNET
ACT 0
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
HOST
1
ETHERNET
ACT 1
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
254
RED ALARM
NC
C
NO
NC
C
NO
YELLOW
ALARM
See Also •
T4000 Connector Interface Panel (CIP) Description on page 14
•
Connecting the T4000 Router to a Management Ethernet Device on page 180
Copyright © 2018, Juniper Networks, Inc.
Chapter 27: Replacing Chassis Components
•
T4000 Routing Engine Interface Cable Specifications on page 113
•
RJ-45 Connector Pinouts for the T4000 Management ETHERNET Port on page 115
Installing a T4000 Management Ethernet Cable
1.
Plug one end of the replacement cable into the appropriate ETHERNET port. The ports labeled HOST 0 connect to the Routing Engine in the upper Routing Engine slot ( RE0 ), and the ports labeled HOST 1 connect to the Routing Engine in the lower Routing
Engine slot ( RE1 ).
2.
Plug the other end of the cable into the network device.
See Also •
T4000 Connector Interface Panel (CIP) Description on page 14
•
Connecting the T4000 Router to a Management Ethernet Device on page 180
•
T4000 Routing Engine Interface Cable Specifications on page 113
•
RJ-45 Connector Pinouts for the T4000 Management ETHERNET Port on page 115
Related
Documentation
•
T4000 Connector Interface Panel (CIP) Description on page 14
•
Connecting the T4000 Router to a Management Ethernet Device on page 180
•
T4000 Routing Engine Interface Cable Specifications on page 113
•
RJ-45 Connector Pinouts for the T4000 Management ETHERNET Port on page 115
Replacing the T4000 Alarm Relay Wires
1.
Removing the T4000 Alarm Relay Wires on page 255
2.
Installing the T4000 Alarm Relay Wires on page 256
Removing the T4000 Alarm Relay Wires
To remove the wires connected to an alarm-reporting device:
1.
Disconnect the existing wire at the external device.
2.
Using a 2.5-mm flat-blade screwdriver, loosen the small screws on the face of the terminal block and remove the block from the relay contact.
3.
Using the 2.5-mm flat-blade screwdriver, loosen the small screws on the side of the terminal block. Remove existing wires from the slots in the front of the block, and insert replacement wires. Tighten the screws to secure the wire.
Copyright © 2018, Juniper Networks, Inc.
255
T4000 Core Router Hardware Guide
Installing the T4000 Alarm Relay Wires
To connect replacement wires to an alarm-reporting device:
1.
Prepare the required length of replacement wire with a gauge between 28 AWG and
14 AWG (0.08 and 2.08 mm
2
).
2.
Plug the terminal block into the relay contact, and use a 2.5-mm flat-blade screwdriver to tighten the screws on the face of the block.
3.
Attach the other end of the wires to the external device.
Related
Documentation
•
T4000 Connector Interface Panel (CIP) Description on page 14
•
Connecting the T4000 Router to an External Alarm-Reporting Device on page 182
•
T4000 Alarm Relay Contact Wire Specifications on page 114
Replacing a T4000 SCG
1.
Removing a T4000 SCG on page 256
2.
Installing a T4000 SCG on page 257
Removing a T4000 SCG
The router can have one or two SCGs installed. The SCGs are located in the upper rear of the chassis, above the control boards and Routing Engines. Each SCG weighs approximately 1.9 lb (0.9 kg).
A nonredundant SCG is hot-pluggable. For redundant SCGs, the master SCG is hot-pluggable. The backup SCG is hot-removable and hot-insertable if the master SCG is functioning. Removing the backup SCG does not affect the functioning of the router.
Taking the master SCG offline might result in a brief loss of SONET clock lock while the backup SCG becomes the master.
To remove an SCG (see
):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Press the online/offline button on the SCG faceplate, and hold it down until the LED goes out (about 5 seconds).
4.
Loosen the captive screws on the edges of the SCG faceplate.
256 Copyright © 2018, Juniper Networks, Inc.
Chapter 27: Replacing Chassis Components
5.
Grasp the SCG by the handle on the faceplate, and slide it out of the chassis.
6.
Place the SCG on the antistatic mat.
Figure 94: Removing an SCG
Installing a T4000 SCG
To install a replacement SCG (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Carefully align the sides of the SCG with the guides in the SCG slot.
3.
Grasp the SCG by its handle, and slide it straight into the chassis until it contacts the midplane.
4.
Tighten the captive screws on the corners of the SCG faceplate.
5.
To bring the SCG online, press the online/offline button until the green OK LED lights.
6.
To verify that the SCG is installed correctly and is functioning normally, check the
LEDs on the SCG faceplate. The green OK LED should light steadily. If the SCG is master, the blue MASTER LED should also light steadily.
To check the status of the SCGs, use the following CLI command: user@host> show chassis environment scg
SCG 0 status:
State Online - Master clock
Temperature 38 degrees C / 100 degrees F
Power
GROUND 0 mV
1.8 V bias 1797 mV
3.3 V 3312 mV
3.3 V bias 3274 mV
5.0 V 5047 mV
Copyright © 2018, Juniper Networks, Inc.
257
T4000 Core Router Hardware Guide
5.0 V bias 4989 mV
5.6 V 5758 mV
8.0 V bias 7560 mV
Bus Revision 40
SCG 1 status:
State Online - Standby
Temperature 38 degrees C / 100 degrees F
Power
GROUND 0 mV
1.8 V bias 1786 mV
3.3 V 3318 mV
3.3 V bias 3286 mV
5.0 V 5037 mV
5.0 V bias 5001 mV
5.6 V 5777 mV
8.0 V bias 7582 mV
Bus Revision 40
Figure 95: Installing an SCG
Related
Documentation
•
T4000 SONET Clock Generators (SCGs) Description on page 20
•
T4000 SONET Clock Generators (SCGs) LEDs on page 22
•
Maintaining the T4000 SCGs on page 333
•
Troubleshooting the T4000 SCGs on page 349
•
Prevention of Electrostatic Discharge Damage on page 423
258 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 28
Replacing Cooling System Components
•
Replacing a T4000 Front Air Filter on page 259
•
Replacing a T4000 Rear Air Filter on page 261
•
Replacing a T4000 Lower Front Fan Tray on page 265
•
Replacing a T4000 Upper Front Fan Tray on page 267
•
Replacing a T4000 Rear Fan Tray on page 269
Replacing a T4000 Front Air Filter
1.
Removing the T4000 Front Air Filter on page 259
2.
Installing the T4000 Front Air Filter on page 260
Removing the T4000 Front Air Filter
The front air filter, located below the FPC card cage in the front of the chassis, installs horizontally. The front air filter weighs approximately 1 lb (0.5 kg). The air filters are hot-insertable and hot-removable.
To remove the front air filter (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Unwrap any PIC cables from the spools on the cable management system, and remove the cables from the tray. Arrange the cables so that they do not block the front of the cable management system and tray, and secure them with temporary fasteners so that they are not supporting their own weight as they hang from the connector.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
3.
Simultaneously pull the two releases on the cable management system. Lift it up and outward to lock it in place to access the air filter.
Copyright © 2018, Juniper Networks, Inc.
259
T4000 Core Router Hardware Guide
4.
Loosen the captive screws on the corners of the air filter faceplate.
5.
Grasp the handles, and pull the air filter straight out of the chassis.
6.
Remove the filter element from the air filter frame (see
Figure 96: Removing the Front Air Filter
Figure 97: Replacing the Front Filter Element
See Also •
Installing the T4000 Front Air Filter
To install the front air filter (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Insert the filter element into the air filter frame.
3.
Grasp the air filter by the handles on its faceplate, and slide it straight into the chassis.
4.
Tighten the captive screws on the corners of the faceplate.
5.
Unlock the cable management system, and lower it to the fully lowered position.
6.
Rearrange the PIC cables in the cable management system.
260 Copyright © 2018, Juniper Networks, Inc.
Figure 98: Installing the Front Air Filter
Chapter 28: Replacing Cooling System Components
See Also •
Related
Documentation
•
Prevention of Electrostatic Discharge Damage on page 423
•
T4000 Cooling System Description on page 25
•
Troubleshooting the T4000 Cooling System on page 351
•
T4000 Clearance Requirements for Airflow and Hardware Maintenance on page 91
•
Maintaining the T4000 Air Filters on page 334
Replacing a T4000 Rear Air Filter
1.
Removing a Rear T4000 Air Filter on page 261
2.
Installing the T4000 Rear Air Filter on page 263
Removing a Rear T4000 Air Filter
The rear air filter is located at the left rear edge of the chassis. The rear air filter weighs less than 1 lb (0.5 kg).
To remove the rear air filter:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Loosen the captive screws at the top, center, and bottom of the air filter, using a
Phillips (+) screwdriver, number 2.
3.
Grasp the air filter cover by the captive screws, and pull firmly to remove the cover and honeycomb assembly from the chassis (see
).
4.
Press the filter element inward until it clears the hooks at the top and bottom of the air filter slot, then push it to the left to unseat it.
Copyright © 2018, Juniper Networks, Inc.
261
T4000 Core Router Hardware Guide
5.
Move the tabs on the filter element to a horizontal position.
6.
Grasp the tabs on the filter element, and carefully pull it straight out from the chassis
(see
Figure 99: Removing the Rear Air Filter
262 Copyright © 2018, Juniper Networks, Inc.
Chapter 28: Replacing Cooling System Components
Figure 100: Removing the Rear Air Filter Element
See Also •
Installing the T4000 Rear Air Filter
To install the rear air filter (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Holding the filter by the tabs, carefully push the filter all the way into the air filter slot.
3.
Holding the filter all the way in, push it to the right side of the slot until it is held in place behind the hooks.
4.
Move the tabs to a vertical position.
Copyright © 2018, Juniper Networks, Inc.
263
T4000 Core Router Hardware Guide
5.
Place the right edge of the honeycomb against the flange of the air filter slot.
6.
Line up the holes at the top, center, and bottom of the honeycomb with the pins in the slot, and press the honeycomb into place.
7.
Replace the air filter cover.
8.
Firmly tighten the captive screws at the top, center, and bottom of the filter cover to secure it to the chassis, using a Phillips (+) screwdriver, number 2.
Figure 101: Installing the Rear Air Filter
264
See Also •
Copyright © 2018, Juniper Networks, Inc.
Chapter 28: Replacing Cooling System Components
Related
Documentation
•
Prevention of Electrostatic Discharge Damage on page 423
•
T4000 Cooling System Description on page 25
•
Troubleshooting the T4000 Cooling System on page 351
•
T4000 Clearance Requirements for Airflow and Hardware Maintenance on page 91
•
Maintaining the T4000 Air Filters on page 334
Replacing a T4000 Lower Front Fan Tray
The lower front fan tray is located below the front air filter. Each front fan tray weighs about 20.4 lb (9.3 kg). The fan trays are hot-insertable and hot-removable. The upper and lower fan trays are interchangeable with each other.
NOTE: Ensure that at any given time only one front fan tray is replaced. Do
NOT replace both the front lower and upper fans simultaneously.
1.
Removing the T4000 Lower Front Fan Tray on page 265
2.
Installing the T4000 Lower Front Fan Tray on page 266
Removing the T4000 Lower Front Fan Tray
1.
Attach an electrostatic discharge (ESD) grounding strap to your wrist, and connect the strap to one of the ESD points on the chassis.
2.
Unwrap any PIC cables from the spools on the front cable management system and remove the cables from the tray. Arrange the cables so that they do not block the front cable management system and tray, and secure them with temporary fasteners so that they are not supporting their own weight as they hang from the connector.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
3.
Simultaneously pull the two releases on the front cable management system. Lift it up and outward to lock it in place to access the lower fan tray.
4.
Rearrange the PIC cables in the front cable management system. For more information about proper cable arrangement, see
“Maintaining T4000 PICs” on page 338 .
5.
Loosen the captive screws on the corners of the fan tray faceplate.
6.
Grasp the handles, and pull the fan tray halfway out of the chassis.
Copyright © 2018, Juniper Networks, Inc.
265
T4000 Core Router Hardware Guide
WARNING: To avoid injury, keep tools and your fingers away from the fans as you slide the fan tray out of the chassis. The fans might still be spinning.
7.
When the fans stop spinning, place one hand under the fan tray to support it, and pull the fan tray completely out of the chassis.
Figure 102: Removing the T4000 Lower Front Fan Tray
FANTRAY-T4000
See Also •
Installing the T4000 Lower Front Fan Tray
To install a lower front fan tray:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the fan tray by its handles, and insert it straight into the chassis.
3.
Tighten the captive screws on each side of the fan tray faceplate to secure it in the chassis.
4.
Unlock the front cable management system and lower it to the fully lowered position.
5.
Rearrange the PIC cables in the front cable management system. For more information about proper cable arrangement, see
“Maintaining T4000 PICs” on page 338 .
266 Copyright © 2018, Juniper Networks, Inc.
Chapter 28: Replacing Cooling System Components
Figure 103: Installing the T4000 Lower Front Fan Tray
FANTRAY-T4000
See Also •
Related
Documentation
•
T4000 Cooling System Description on page 25
•
Troubleshooting the T4000 Cooling System on page 351
•
T4000 Clearance Requirements for Airflow and Hardware Maintenance on page 91
•
Maintaining the T4000 Fan Trays on page 335
Replacing a T4000 Upper Front Fan Tray
The upper front fan tray is located above the FPC card cage. Each front fan tray weighs about 20.4 lb (9.3 kg). The fan trays are hot-insertable and hot-removable. The upper and lower fan trays are interchangeable with each other.
NOTE: Ensure that at any given time only one front fan tray is replaced. Do
NOT replace both the front lower and upper fans simultaneously.
1.
Removing the T4000 Upper Front Fan Tray on page 267
2.
Installing the T4000 Upper Front Fan Tray on page 269
Removing the T4000 Upper Front Fan Tray
To remove an upper front fan tray (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Loosen the captive screws on the corners of the fan tray faceplate.
3.
Grasp the handles, and pull the fan tray halfway out of the chassis.
Copyright © 2018, Juniper Networks, Inc.
267
T4000 Core Router Hardware Guide
WARNING: To avoid injury, keep tools and your fingers away from the fans as you slide the fan tray out of the chassis. The fans might still be spinning.
4.
When the fans stop spinning, place one hand under the fan tray to support it, and pull the fan tray completely out of the chassis.
Figure 104: Removing an Upper Front Fan Tray
FANTRAY-T4000
T Series
FANTRAY-T4000
268
See Also •
FANTRA
Y-T4000
Copyright © 2018, Juniper Networks, Inc.
Chapter 28: Replacing Cooling System Components
Installing the T4000 Upper Front Fan Tray
To install an upper front fan tray (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the fan tray by its handles, and insert it straight into the chassis.
3.
Tighten the captive screws on each side of the fan tray faceplate to secure it in the chassis.
Figure 105: Installing an Upper Front Fan Tray
T Series
FANTRAY-T4000
FANTRAY-T4000
See Also •
Related
Documentation
•
T4000 Cooling System Description on page 25
•
Troubleshooting the T4000 Cooling System on page 351
•
T4000 Clearance Requirements for Airflow and Hardware Maintenance on page 91
•
Maintaining the T4000 Fan Trays on page 335
Replacing a T4000 Rear Fan Tray
The rear fan tray is mounted vertically on the right side of the rear of the chassis. The rear fan tray contains eight fans, and is not interchangeable with the front fan trays. The rear fan tray must be used in conjunction with the front fan trays. The rear fan tray weighs about 10 lb (4.5 kg).
Copyright © 2018, Juniper Networks, Inc.
269
T4000 Core Router Hardware Guide
CAUTION: To maintain proper cooling, do not operate the routing node with the rear fan tray removed for more than one minute.
1.
Removing the T4000 Rear Fan Tray on page 270
2.
Installing the T4000 Rear Fan Tray on page 271
Removing the T4000 Rear Fan Tray
To remove the rear fan tray (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point.
2.
Loosen the captive screws on the top and bottom of the fan tray faceplate.
3.
Grasp the handles, and pull the fan tray halfway out of the chassis.
4.
Wait for the fans to stop spinning.
5.
After the fans stop spinning, place one hand under the fan tray to support it, and pull the fan tray completely out of the chassis.
270 Copyright © 2018, Juniper Networks, Inc.
Chapter 28: Replacing Cooling System Components
Figure 106: Removing the FAN-R-TXP-3D-LCC Rear Fan Tray
See Also •
Installing the T4000 Rear Fan Tray
To install a replacement rear fan tray (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the fan tray by its handles, and insert it straight into the chassis.
3.
Tighten the captive screws on the fan tray faceplate to secure it in the chassis, using a Phillips (+) screwdriver, number 2.
Copyright © 2018, Juniper Networks, Inc.
271
T4000 Core Router Hardware Guide
Figure 107: Installing the Rear Fan Tray
272
See Also •
Related
Documentation
•
T4000 Cooling System Description on page 25
•
T4000 Clearance Requirements for Airflow and Hardware Maintenance on page 91
•
Maintaining the T4000 Fan Trays on page 335
•
Troubleshooting the T4000 Cooling System on page 351
•
Prevention of Electrostatic Discharge Damage on page 423
Copyright © 2018, Juniper Networks, Inc.
CHAPTER 29
Replacing Host Subsystem Components
•
Replacing T4000 Host Subsystem Components on page 273
•
Replacing a T4000 LCC-CB on page 275
•
Replacing a T4000 Routing Engine on page 280
•
Replacing a CompactFlash Card in a T4000 RE-C1800 Routing Engine on page 286
•
Replacing a DIMM Module in a T4000 RE-C1800 Routing Engine on page 289
•
Replacing a Solid-State Disk in a T4000 RE-C1800 Routing Engine on page 290
Replacing T4000 Host Subsystem Components
1.
Taking the T4000 Host Subsystem Offline on page 273
2.
Replacing a Control Board or Routing Engine Component on page 275
Taking the T4000 Host Subsystem Offline
Before you replace a control board or Routing Engine,, you must take the host subsystem offline. The host subsystem is taken offline and brought online as a unit. Normally, if two host subsystems are installed in the router, RE0 functions as the master and RE1 functions as the backup.
NOTE: Router performance might change if the backup Routing Engine's configuration differs from the former master's configuration. For the most predictable performance, configure the two Routing Engines identically, except for parameters unique to each Routing Engine.
NOTE: For information about high availability features, configuring graceful switchover and nonstop active routing, see the Junos OS High Availability
Library for Routing Devices.
explains the effect of taking the host subsystem offline.
Copyright © 2018, Juniper Networks, Inc.
273
T4000 Core Router Hardware Guide
Table 79: Effect of Taking the Host Subsystem Offline
Type of Host
Subsystem Effect of taking the Host Subsystem Offline
Nonredundant host subsystem
The router shuts down.
Backup host subsystem
Master host subsystem
The functioning of the router is not interrupted. The backup host subsystem is hot-removable and hot-insertable.
The backup host subsystem becomes the master. The backup Routing
Engine assumes Routing Engine functions. The master host subsystem is hot-pluggable. Removal or failure of the master Routing Engine affects forwarding and routing based on the high availability configuration:
•
•
Dual Routing Engines without any high availability features enabled—Traffic is interrupted while the Packet Forwarding Engine is reinitialized. All kernel and forwarding processes are restarted. When the switchover to the new master Routing Engine is complete, routing convergence takes place and traffic is resumed.
Graceful Routing Engine switchover (GRES) is enabled—Graceful
Routing Engine switchover preserves interface and kernel information.
Traffic is not interrupted. However, graceful Routing Engine switchover does not preserve the control plane. Neighboring routers detect that the router has restarted and react to the event in a manner prescribed by individual routing protocol specifications. To preserve routing without interruption during a switchover, graceful Routing Engine switchover must be combined with nonstop active routing.
NOTE: Graceful Routing Engine switchover (GRES) is supported on
Junos OS Release 12.1R2 and later for T4000 routers.
• Nonstop active routing is enabled (graceful Routing Engine switchover must be configured for nonstop active routing to be enabled)—Nonstop active routing supports Routing Engine switchover without alerting peer nodes that a change has occurred. Nonstop active routing uses the same infrastructure as graceful Routing Engine switchover to preserve interface and kernel information. However, nonstop active routing also preserves routing information and protocol sessions by running the routing protocol process (rpd) on both Routing Engines. In addition, nonstop active routing preserves TCP connections maintained in the kernel.
Nonstop active routing is supported on Junos OS Release 12.1R2 and later for T4000 routers,
• Graceful restart is configured—Graceful restart provides extensions to routing protocols so that neighboring helper routers restore routing information to a restarting router. These extensions signal neighboring routers about the graceful restart and prevent the neighbors from reacting to the router restart and from propagating the change in state to the network during the graceful restart period. Neighbors provide the routing information that enables the restarting router to stop and restart routing protocols without causing network reconvergence. Neighbors are required to support graceful restart. The routing protocol process
(rpd) restarts. A graceful restart interval is required. For certain protocols, a significant change in the network can cause graceful restart to stop.
274 Copyright © 2018, Juniper Networks, Inc.
Chapter 29: Replacing Host Subsystem Components
Replacing a Control Board or Routing Engine Component
NOTE: To replace a solid-state disk or CompactFlash card, you must power off the Routing Engine.
After you take the host subsystem offline, you can replace the following host subsystem components:
•
Replacing a T4000 LCC-CB on page 275
•
Replacing a T4000 Routing Engine on page 280
•
Replacing a CompactFlash Card in a T4000 RE-C1800 Routing Engine on page 286
•
Replacing a Solid-State Disk in a T4000 RE-C1800 Routing Engine on page 290
•
Replacing a DIMM Module in a T4000 RE-C1800 Routing Engine on page 289
See Also •
Related
Documentation
•
T4000 Host Subsystem Description on page 29
•
Prevention of Electrostatic Discharge Damage on page 423
• request system halt
Replacing a T4000 LCC-CB
The router can have up to two LCC-CBs. They are located in the upper rear of the chassis in the slots marked CB0 and CB1 . Each LCC-CB weighs approximately 5 lb (2.3 kg).
CAUTION: Before you replace a control board, you must take the host subsystem offline. The backup control board is hot-removable and hot-insertable. If the control board to be replaced is associated with the
Routing Engine currently functioning as the master Routing Engine, switch the master to the backup before removing the control board. If there is only one host subsystem, taking the host subsystem offline shuts down the router.
1.
Taking the Host Subsystem Offline on page 276
2.
Removing a T4000 LCC-CB on page 277
3.
Installing a T4000 LCC-CB on page 278
Copyright © 2018, Juniper Networks, Inc.
275
T4000 Core Router Hardware Guide
Taking the Host Subsystem Offline
To take a host subsystem offline:
1.
Determine whether the host subsystem is functioning as the master or as the backup, using one of the two following methods:
• Check the Routing Engine LEDs on the craft interface. If the green MASTER LED is lit, the corresponding host subsystem is functioning as the master.
• Use the show chassis routing-engine command to determine which Routing Engine is the master. In this example, the master Routing Engine in Slot 0 is designated
Master in the Current state field: user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
Temperature 38 degrees C / 100 degrees F
CPU temperature 56 degrees C / 132 degrees F
DRAM 8960 MB
Memory utilization 20 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 4 percent
Interrupt 1 percent
Idle 95 percent
Model RE-DUO-1800
Serial ID P737F-002693
Start time 2011-12-08 21:04:20 PST
Uptime 1 day, 13 hours, 22 minutes, 57 seconds
Last reboot reason Router rebooted after a normal shutdown.
Load averages: 1 minute 5 minute 15 minute
0.04 0.05 0.01
Routing Engine status:
Slot 1:
Current state Backup
Election priority Backup (default)
Temperature 38 degrees C / 100 degrees F
CPU temperature 53 degrees C / 127 degrees F
DRAM 8960 MB
Memory utilization 17 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 1 percent
Interrupt 1 percent
Idle 98 percent
Model RE-DUO-1800
Serial ID P737F-002587
Start time 2011-12-08 20:57:51 PST
Uptime 1 day, 13 hours, 29 minutes, 11 seconds
Last reboot reason Router rebooted after a normal shutdown.
2.
If the host subsystem is functioning as the master, switch it to backup using the CLI
276 Copyright © 2018, Juniper Networks, Inc.
Chapter 29: Replacing Host Subsystem Components command: user@host> request chassis routing-engine master switch
3.
To halt the router: user@host> request system halt
If two Routing Engines are installed, also issue the command on the backup Routing
Engine. Wait until a message appears on the console confirming that the operating system has halted.
The command shuts down the Routing Engine cleanly, so its state information is preserved.
NOTE: The SIBs might continue forwarding traffic for approximately 5 minutes after the request system halt command has been issued.
4.
To take the control board offline, issue the following command.
user@host> request chassis cb offline slot n n is 0 or 1 for the slot number of the host subsystem being taken offline.
5.
Verify that the control board is offline: user@host> show chassis environment cb 0
Removing a T4000 LCC-CB
To remove an LCC-CB (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Loosen the captive screws (using a Phillips (+) screwdriver, number 2) on the ejector handles on both sides of the LCC-CB faceplate.
4.
Flip the ejector handles outward to unseat the LCC-CB.
5.
Grasp the ejector handles, and slide the LCC-CB about halfway out of the chassis.
6.
Place one hand underneath the LCC-CB to support it, and slide it completely out of the chassis.
Copyright © 2018, Juniper Networks, Inc.
277
T4000 Core Router Hardware Guide
7.
Place the LCC-CB on the antistatic mat.
8.
If you are not replacing the LCC-CB now, install a blank panel over the empty slot.
Figure 108: Removing an LCC-CB
Installing a T4000 LCC-CB
To install an LCC-CB (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Verify that the CHASSIS ID and M/S switches on the LCC-CB faceplate are set correctly for your configuration. If you are installing the LCC-CB in a standalone router, the M/S switch must be set to S and the CHASSIS ID configuration switch must be set to 0 .
NOTE: See Setting the Chassis ID and M/S Switch on the LCC-CB in the TX
Matrix Plus Router Hardware Guide for instructions to set the switches when installing the LCC-CB in a T4000 that is part of a routing matrix.
3.
Carefully align the sides of the LCC-CB with the guides inside the chassis.
4.
Slide the LCC-CB into the chassis, carefully ensuring that it is correctly aligned.
5.
Grasp both ejector handles, and press them inward to seat the LCC-CB.
278 Copyright © 2018, Juniper Networks, Inc.
Chapter 29: Replacing Host Subsystem Components
6.
Tighten the captive screws on the ejector handles, using a Phillips (+) screwdriver, number 2.
7.
Verify that the LCC-CB is functioning normally:
• Check the LEDs on the LCC-CB faceplate. The green OK LED should light steadily a few minutes after the LCC-CB is installed. If power is applied to the Routing Engine and its corresponding LCC-CB is functioning normally, the LCC-CB comes online automatically.
If the FAIL LED is lit steadily, remove and install the LCC-CB again. If the FAIL LED still lights steadily, the LCC-CB is not functioning properly. Contact your customer support representative.
• Use the show chassis environment cb command to check the status of the LCC-CB.
show chassis environment cb
CB 0 status:
State Online Master
Temperature 38 degrees C / 100 degrees F
Power 1
1.8 V 1800 mV
2.5 V 2501 mV
3.3 V 3288 mV
3.3 V bias 3296 mV
4.6 V 4682 mV
5.0 V 4923 mV
8.0 V bias 7755 mV
12.0 V 11887 mV
Power 2
1.0 V 989 mV
1.2 V 1186 mV
3.3 V RE 3321 mV
Bus Revision 51
FPGA Revision 5
CB 1 status:
State Online Standby
Temperature 40 degrees C / 104 degrees F
Power 1
1.8 V 1802 mV
2.5 V 2518 mV
3.3 V 3297 mV
3.3 V bias 3274 mV
4.6 V 4693 mV
5.0 V 4959 mV
8.0 V bias 7746 mV
12.0 V 11897 mV
Power 2
1.0 V 991 mV
1.2 V 1200 mV
3.3 V RE 3315 mV
Bus Revision 51
FPGA Revision 5
Copyright © 2018, Juniper Networks, Inc.
279
T4000 Core Router Hardware Guide
Figure 109: Installing an LCC-CB
See Also •
•
•
Related
Documentation
•
T4000 Control Board Description on page 30
•
•
T4000 LCC-CB Control Board LEDs on page 31
•
Replacing T4000 Host Subsystem Components on page 273
Replacing a T4000 Routing Engine
The router can have one or two Routing Engines. They are located in the upper rear of the chassis in the slots marked RE0 and RE1 . Each Routing Engine can weigh up to
2.4 lb (1.1 kg). The backup Routing Engine is hot-removable and hot-insertable.
CAUTION: Before you replace a Routing Engine, you must take the host subsystem offline. If there is only one host subsystem, taking the host subsystem offline shuts down the router. If the Routing Engine to be replaced
280 Copyright © 2018, Juniper Networks, Inc.
Chapter 29: Replacing Host Subsystem Components is currently functioning as the master Routing Engine, switch it to be the backup before removing it.
1.
Taking the Host Subsystem Offline on page 281
2.
Removing a T4000 Routing Engine on page 282
3.
Installing a T4000 Routing Engine on page 284
Taking the Host Subsystem Offline
To take a host subsystem offline:
1.
Determine whether the host subsystem is functioning as the master or as the backup, using one of the two following methods:
• Check the Routing Engine LEDs on the craft interface. If the green MASTER LED is lit, the corresponding host subsystem is functioning as the master.
• Use the show chassis routing-engine command to determine which Routing Engine is the master. In this example, the master Routing Engine in Slot 0 is designated
Master in the Current state field: user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
Temperature 38 degrees C / 100 degrees F
CPU temperature 56 degrees C / 132 degrees F
DRAM 8960 MB
Memory utilization 20 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 4 percent
Interrupt 1 percent
Idle 95 percent
Model RE-DUO-1800
Serial ID P737F-002693
Start time 2011-12-08 21:04:20 PST
Uptime 1 day, 13 hours, 22 minutes, 57 seconds
Last reboot reason Router rebooted after a normal shutdown.
Load averages: 1 minute 5 minute 15 minute
0.04 0.05 0.01
Routing Engine status:
Slot 1:
Current state Backup
Election priority Backup (default)
Temperature 38 degrees C / 100 degrees F
CPU temperature 53 degrees C / 127 degrees F
DRAM 8960 MB
Memory utilization 17 percent
CPU utilization:
User 0 percent
Background 0 percent
Copyright © 2018, Juniper Networks, Inc.
281
T4000 Core Router Hardware Guide
Kernel 1 percent
Interrupt 1 percent
Idle 98 percent
Model RE-DUO-1800
Serial ID P737F-002587
Start time 2011-12-08 20:57:51 PST
Uptime 1 day, 13 hours, 29 minutes, 11 seconds
Last reboot reason Router rebooted after a normal shutdown.
2.
If the host subsystem is functioning as the master, switch it to backup using the CLI command: user@host> request chassis routing-engine master switch
3.
To halt the router: user@host> request system halt
If two Routing Engines are installed, also issue the command on the backup Routing
Engine. Wait until a message appears on the console confirming that the operating system has halted.
The command shuts down the Routing Engine cleanly, so its state information is preserved.
NOTE: The SIBs might continue forwarding traffic for approximately 5 minutes after the request system halt command has been issued.
Removing a T4000 Routing Engine
To remove a Routing Engine (see
):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Loosen the captive screws on the corners of the Routing Engine cover.
4.
Grasp the Routing Engine cover by its edges, and pull it free from the chassis (see
5.
If applicable, loosen the screws on the extractor handles at either end of the Routing
Engine faceplate, using a Phillips screwdriver.
6.
Press the red tabs on the ejector handles on both sides of the Routing Engine faceplate.
7.
Flip the ejector handles outward to unseat the Routing Engine.
282 Copyright © 2018, Juniper Networks, Inc.
Chapter 29: Replacing Host Subsystem Components
8.
Grasp the Routing Engine by the ejector handles, and slide it about halfway out of the chassis.
9.
Place one of your hands underneath the Routing Engine to support it, and slide it completely out of the chassis.
10.
Place the Routing Engine on the antistatic mat.
11.
If you are not replacing the Routing Engine now, reinstall the Routing Engine cover, and tighten the screws on the corners of the cover to secure it to the chassis.
Figure 110: Removing the Routing Engine Cover
Figure 111: Removing a T4000 C1800 Routing Engine
Copyright © 2018, Juniper Networks, Inc.
283
T4000 Core Router Hardware Guide
Installing a T4000 Routing Engine
To install a Routing Engine (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Ensure that the ejector handles are not in the locked position. If necessary, press the red tabs and flip the ejector handles outward.
3.
Place one hand underneath the Routing Engine to support it. With the other hand, grasp one of the ejector handles on the faceplate.
4.
Carefully align the sides of the Routing Engine with the guides inside the chassis.
5.
Slide the Routing Engine into the chassis until you feel resistance, then press the
Routing Engine's faceplate until it engages the midplane connectors.
6.
Press both the ejector handles inward to seat the Routing Engine.
The Routing Engine might require several minutes to boot.
7.
If applicable, tighten the screws on the extractor handles, by using a Phillips screwdriver. Be sure to tighten the screws enough to seat the Routing Engine properly.
8.
Press the Routing Engine cover into place, then tighten the captive screws on the corners of the cover to secure it to the chassis (see
284 Copyright © 2018, Juniper Networks, Inc.
Figure 112: Installing a Routing Engine
Chapter 29: Replacing Host Subsystem Components
Figure 113: Reinstalling the Routing Engine Cover
Related
Documentation
•
T4000 Host Subsystem Description on page 29
•
T4000 Routing Engine Description on page 33
•
T4000 RE-C1800 Routing Engine Description on page 34
•
T4000 RE-C1800 LEDs on page 35
•
Maintaining the T4000 Routing Engines on page 336
•
Troubleshooting the T4000 Routing Engines on page 355
•
Replacing T4000 Host Subsystem Components on page 273
•
Prevention of Electrostatic Discharge Damage on page 423
Copyright © 2018, Juniper Networks, Inc.
285
T4000 Core Router Hardware Guide
Replacing a CompactFlash Card in a T4000 RE-C1800 Routing Engine
1.
Preparing to Replace a CompactFlash Card in a T4000 RE-C1800 Routing
2.
Removing a CompactFlash Card from a T4000 RE-C1800 Routing Engine on page 286
3.
Installing a CompactFlash Card into a T4000 RE-C1800 Routing Engine on page 287
4.
Copying Junos OS to the CompactFlash Card in a T1600 RE-C1800 Routing
Preparing to Replace a CompactFlash Card in a T4000 RE-C1800 Routing Engine
The CompactFlash card is located in the slot labeled CF on the Routing Engine faceplate.
To prepare to replace the CompactFlash card:
1.
Determine whether the host subsystem is functioning as the master or as the backup, using one of these methods:
• Check the Host Subsystem LEDs on the craft interface. If the green MASTER LED is lit, the corresponding host subsystem is functioning as the master.
• Check the MASTER LED on the control board. If the blue MASTER LED is lit, the host subsystem is functioning as the master.
• Issue the show chassis routing-engine command: user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
...
In these examples, the Routing Engine in slot 0 is designated Master in the Current state field
2.
If the host subsystem is functioning as the master, switch it to backup. Issue the request chassis routing-engine master switch command.
3.
From the master Routing Engine, power down the backup Routing Engine. Issue the request system power-off other-routing-engine command.
Removing a CompactFlash Card from a T4000 RE-C1800 Routing Engine
The CompactFlash card is located in the slot labeled CF on the Routing Engine faceplate.
To remove the CompactFlash card (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Verify that the Online , DISK1 , and CF LEDs on the backup Routing Engine faceplate are off.
286 Copyright © 2018, Juniper Networks, Inc.
Chapter 29: Replacing Host Subsystem Components
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
Using a Phillips (+) screwdriver, number 2, loosen the captive screws on the corners of the cover over the Routing Engine slots.
5.
Remove the cover from the Routing Engine slots.
CAUTION: Do not remove the cover if any of the LEDs are lit.
6.
Press the eject button on the right side of the CompactFlash card slot to release the
CompactFlash card.
7.
The CompactFlash card pops partially out of the slot. Grasp the card and pull it completely out of the slot.
8.
Place the CompactFlash card on the antistatic mat.
Figure 114: Removing a CompactFlash Card
Disk 2
Disk 1
CF
Disk 2
Disk 1
CF
D
S
I
CF
K
1
D
I
S
K
2
USB
Offline
Online
Installing a CompactFlash Card into a T4000 RE-C1800 Routing Engine
To install a CompactFlash card (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Insert the CompactFlash card into the CompactFlash card slot on the Routing Engine, with the logo facing up.
CAUTION: Be sure to insert the CompactFlash card with the label facing up. Inserting the CompactFlash card incorrectly might damage the Routing
Engine.
3.
Press the card firmly all the way into the slot.
Copyright © 2018, Juniper Networks, Inc.
287
T4000 Core Router Hardware Guide
4.
Reinstall the Routing Engine cover. Using a Phillips (+) screwdriver, number 2, tighten the screws on the corners of the cover to secure it to the Routing Engine.
5.
From the master Routing Engine, power on the Routing Engine. Issue the request system power-on other-routing-engine command.
NOTE: After you replace a CompactFlash card, the Routing Engine boots from the solid-state disk (SSD). You may get an error message and be prompted for a keystroke. After you press the keystroke, it might take up to 10 minutes for the Routing Engine to reset and for the router to boot from the SSD.
Figure 115: Installing a CompactFlash Card
Disk 2
Disk 1
CF
Disk 2
Disk 1
CF CF
K
1
D
S
I
S
K
2
D
I
USB
Offline
Online
Reset
Copying Junos OS to the CompactFlash Card in a T1600 RE-C1800 Routing Engine
After installing the CompactFlash card for the first time, you must copy the software from the Routing Engine's solid-state disk (SSD) to the CompactFlash card.
To copy software to the CompactFlash card:
1.
On the console or other management device connected to the Routing Engine, enter
CLI operational mode and copy the currently running and active file system partitions on the router to standby partitions on the CompactFlash card. Issue the request system snapshot partition command.
2.
Wait until a message appears on the console confirming that the snapshot partition procedure is complete.
3.
Issue the request system reboot command to reboot the router's software.
4.
Issue the show system boot-messages command to verify that the CompactFlash card is listed as the primary boot device. The output lists the devices mounted. The
CompactFlash card is located at ad0 .
Related
Documentation
•
T4000 Routing Engine Description on page 33
•
T4000 RE-C1800 Routing Engine Description on page 34
•
T4000 RE-C1800 LEDs on page 35
288 Copyright © 2018, Juniper Networks, Inc.
Chapter 29: Replacing Host Subsystem Components
• T4000 Craft Interface LEDs
•
Prevention of Electrostatic Discharge Damage on page 423
Replacing a DIMM Module in a T4000 RE-C1800 Routing Engine
1.
Removing a DIMM Module from a T4000 RE-C1800 Routing Engine on page 289
2.
Installing a DIMM Module into a T4000 RE-C1800 Routing Engine on page 289
Removing a DIMM Module from a T4000 RE-C1800 Routing Engine
To remove a DIMM module:
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Remove the Routing Engine. See
“Replacing a T4000 Routing Engine” on page 280 .
4.
Eject the DIMM module by pressing the plastic ejectors on both sides of the DIMM module.
5.
Grasp the DIMM module, being careful not to touch any electrical components on the module, and firmly pull it out of the slot on the Routing Engine.
6.
Place the DIMM module on the antistatic mat or in the electrostatic bag.
7.
Push the plastic ejectors to close the empty DIMM module slot.
Installing a DIMM Module into a T4000 RE-C1800 Routing Engine
To insert a DIMM module into the Routing Engine:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Remove the DIMM module from its electrostatic bag.
3.
To open the empty DIMM slot, press the plastic ejectors open.
4.
Grasp the DIMM module by the edges, being careful not to touch any electrical components.
5.
Press firmly on both ends, and push the module into the slot until the ejectors return completely to the closed position.
6.
Install the Routing Engine. See
“Replacing a T4000 Routing Engine” on page 280
.
7.
You can view the SDRAM configuration and verify that the DIMM was installed correctly by issuing the show chassis routing-engine command.
Related
Documentation
•
T4000 Routing Engine Description on page 33
•
T4000 RE-C1800 Routing Engine Description on page 34
Copyright © 2018, Juniper Networks, Inc.
289
T4000 Core Router Hardware Guide
•
T4000 RE-C1800 LEDs on page 35
• T4000 Craft Interface LEDs
•
Prevention of Electrostatic Discharge Damage on page 423
Replacing a Solid-State Disk in a T4000 RE-C1800 Routing Engine
1.
Preparing to Replace a Solid-State Disk from a T4000 RE-C1800 Routing
2.
Removing a Solid-State Disk from a T4000 RE-C1800 Routing Engine on page 291
3.
Installing a Solid-State Disk From a T4000 RE-C1800 Routing Engine on page 292
4.
Copying Junos OS to the Solid-State Disk in a T4000 RE-C1800 Routing
Preparing to Replace a Solid-State Disk from a T4000 RE-C1800 Routing Engine
To prepare to replace an SSD:
1.
Determine whether the host subsystem is functioning as the master or as the backup, using one of these methods:
• Check the Host Subsystem LEDs on the craft interface. If the green MASTER LED is lit, the corresponding host subsystem is functioning as the master.
• Check the MASTER LED on the control board. If the blue MASTER LED is lit, the host subsystem is functioning as the master.
• Issue the show chassis routing-engine . command.
user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
...
2.
If the host subsystem is functioning as the master, switch it to backup. Issue the request chassis routing-engine master switch command.
3.
From the master Routing Engine, power down the backup Routing Engine. Issue the request system power-off other-routing-engine command.
290 Copyright © 2018, Juniper Networks, Inc.
Chapter 29: Replacing Host Subsystem Components
Removing a Solid-State Disk from a T4000 RE-C1800 Routing Engine
The solid-state disk (SSD) is located in the slot labeled DISK1 on the Routing Engine faceplate.
NOTE: The DISK2 slot is not currently supported.
To remove an SSD from a Routing Engine (see
):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Verify that the Online , DISK1 , and CF LEDs on the backup Routing Engine faceplate are off.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
Using a Phillips (+) screwdriver, number 2, loosen the captive screws on the corners of the cover.
5.
Remove the cover from the Routing Engine slots.
CAUTION: Do not remove the cover if any of the LEDs on the Routing
Engine faceplate are lit.
6.
Press the eject button on the right side of the DISK1 slot to release the SSD.
7.
The SSD pops partially out of the slot. Grasp the SSD and carefully slide it completely out of the slot.
8.
Place the SSD on the antistatic mat.
Figure 116: Removing an SSD
Disk 2
Disk 1
CF
Disk 2
Disk 1
CF CF
S
K
1
D
I
K
2
D
I
S
USB
Offline
Online
Copyright © 2018, Juniper Networks, Inc.
291
T4000 Core Router Hardware Guide
Installing a Solid-State Disk From a T4000 RE-C1800 Routing Engine
To install an SSD in a Routing Engine (see
1.
Insert the SSD into the DISK1 slot on the Routing Engine, with the logo facing down.
CAUTION: Be sure to insert the SSD with the label facing down. Inserting the SSD incorrectly might damage the Routing Engine.
2.
Slide the SSD into the slot until you feel resistance, carefully ensuring that it is correctly aligned.
3.
Reinstall the Routing Engine cover. Using a Phillips (+) screwdriver, number 2, tighten the screws on the corners of the cover to secure it to the Routing Engine .
4.
From the master Routing Engine, power on the Routing Engine. Issue the request system power-on other-routing-engine command.
Figure 117: Installing an SSD
Disk 2
Disk 1
CF
Disk 2
Disk 1
CF
CF
K
1
D
I
S
S
K
2
D
I
USB
Offline
Online
Copying Junos OS to the Solid-State Disk in a T4000 RE-C1800 Routing Engine
After installing a solid-state disk (SSD) for the first time, you must copy the software from the Routing Engine's CompactFlash card to the SSD.
To copy software to the SSD:
1.
On the console or other management device connected to the Routing Engine, enter
CLI operational mode.
2.
Partition the SSD. Issue the request system partition hard-disk command.
3.
Wait until a message appears on the console confirming that the partition procedure is complete.
4.
Reboot the router's software. Issue the request system reboot command.
292 Copyright © 2018, Juniper Networks, Inc.
Chapter 29: Replacing Host Subsystem Components
5.
Back up the currently running and active file system partitions on the router to standby partitions that are not running. Issue the request system snapshot command.
6.
Wait until a message appears on the console confirming that the snapshot procedure is complete.
7.
Reboot the router's software again. Issue the request system reboot command.
8.
Verify that the SSD is listed as the secondary boot device. The output lists the devices mounted. The SSD is located at ad1 . Issue the show system boot-messages command.
Related
Documentation
•
T4000 Routing Engine Description on page 33
•
T4000 RE-C1800 Routing Engine Description on page 34
•
T4000 RE-C1800 LEDs on page 35
• T4000 Craft Interface LEDs
•
Prevention of Electrostatic Discharge Damage on page 423
Copyright © 2018, Juniper Networks, Inc.
293
T4000 Core Router Hardware Guide
294 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 30
Replacing Line Card Components
•
Replacing a T4000 FPC on page 295
•
Replacing a T4000 PIC on page 301
Replacing a T4000 FPC
The FPCs are hot-insertable and hot-removable. When you remove an FPC, the router continues to function, although the PIC interfaces installed on the FPC being removed no longer function.
The router holds up to eight FPCs, which are installed vertically in the front of the router.
An empty FPC weighs approximately 25 lb (11.3 kg), and an FPC with PICs installed can weigh up to 33.5 lb (15.1 kg).
Each FPC slot not occupied by an FPC must be covered by an FPC blank panel. An FPC blank panel weighs 9 lb (4.2 kg).
1.
Removing a T4000 FPC on page 295
2.
Installing a T4000 FPC on page 298
Removing a T4000 FPC
To remove an FPC (see
):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Before removing an FPC, record its location in the chassis so that you can reinstall each FPC in the correct slot.
4.
Use one of the following methods to take the FPC offline:
• Press and hold the FPC online/offline button. The green OK LED next to the button begins to blink. Hold the button down until the LED goes out. The LEDs and online/offline button for each FPC are located directly above it on the craft interface.
• Issue the following CLI command:
Copyright © 2018, Juniper Networks, Inc.
295
T4000 Core Router Hardware Guide user@host> request chassis fpc slot slot-number offline
5.
Disconnect the cables from the PICs installed in the FPC. If a PIC uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap. Arrange the disconnected cables in the cable management system, to prevent the cables from developing stress points.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
6.
If necessary, remove each installed PIC from the FPC.
7.
After you remove each PIC, immediately place it on an antistatic mat or in an electrostatic bag.
Do not stack components on top of one another after removal. Place each one individually in an electrostatic bag or on its own antistatic mat on a flat, stable surface.
8.
Simultaneously turn both the ejector handles counterclockwise to unseat the FPC.
9.
Grasp the handles, and slide the FPC straight out of the card cage halfway.
10.
Place one hand around the front of the FPC (the PIC housing) and the other hand under it to support it. Slide the FPC completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.
CAUTION: The weight of the FPC is concentrated in the back end. Be prepared to accept the full weight—up to 33.5 lb (15.1 kg)—as you slide the FPC out of the chassis.
296 Copyright © 2018, Juniper Networks, Inc.
Chapter 30: Replacing Line Card Components
When the FPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
11.
If you are not reinstalling an FPC into the emptied FPC slot within a short time, install a blank FPC panel over the slot to maintain proper airflow in the FPC card cage.
CAUTION: After removing an FPC from the chassis, wait at least 30 seconds before reinserting it, removing an FPC from a different slot, or inserting an FPC into a different slot.
Figure 118: Removing an FPC
T-1600 FPC4
See Also •
T4000 FPC Description on page 57
Copyright © 2018, Juniper Networks, Inc.
297
T4000 Core Router Hardware Guide
• T4000 Craft Interface LEDs
•
Maintaining T4000 FPCs on page 337
•
Troubleshooting the T4000 FPCs on page 358
•
Prevention of Electrostatic Discharge Damage on page 423
Installing a T4000 FPC
CAUTION: The FPC power connector is located in the corner where the bottom and the connector edges meet. If a power connector prong becomes bent, it no longer aligns with the female connector on the midplane, and the FPC no longer functions.
To install an FPC (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Place the FPC on an antistatic mat.
3.
Take each PIC to be installed in the replacement FPC out of its electrostatic bag and identify the slot on the FPC where it will be connected.
4.
Verify that each fiber-optic PIC has a rubber safety cap covering the PIC transceiver.
If it does not, cover the transceiver with a safety cap.
5.
Install each PIC into the appropriate slot on the FPC. For information about installing a PIC, see
“Installing a T4000 PIC” on page 303 ..
6.
Locate the slot in the FPC card cage in which you plan to install the FPC.
7.
Inspect the slot in the FPC card cage to verify that there are no missing or bent pins on the midplane.
8.
Inspect the FPC to verify that the connectors are not misaligned or damaged.
9.
Orient the FPC vertically with the component side facing to the right. Be sure the FPC is right-side up, with the components on the right of the FPC.
CAUTION: When the FPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
298 Copyright © 2018, Juniper Networks, Inc.
Chapter 30: Replacing Line Card Components
10.
Carefully align the connector edge of the FPC with the appropriate empty slot in the chassis.
11.
Lift the FPC into place, and carefully align the bottom and top of the FPC with the guides inside the card cage.
Figure 119: Installing an FPC
Do not bend or damage prongs on power connector
12.
Gently rest the bottom edge of the FPC on the bottom edge of the slot opening, making contact a short distance forward of the power connector.
CAUTION: Take care not to bend or otherwise damage the power connector prongs.
13.
Slowly slide the FPC into the slot until you feel resistance.
14.
Align the ejector handles on the FPC faceplate in a position close to horizontal.
Copyright © 2018, Juniper Networks, Inc.
299
T4000 Core Router Hardware Guide
300
15.
Simultaneously turn both ejector handles clockwise until you cannot turn them farther.
16.
If any of the PICs on the FPC connect to fiber-optic cable, remove the rubber safety cap from each transceiver and cable.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
17.
Insert the appropriate cable into the cable connector ports on each PIC on the FPC.
Secure the cables so that they are not supporting their own weight. Place excess cable out of the way in a neatly coiled loop, using the cable management system. Placing fasteners on a loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
18.
Use one of the following methods to bring the FPC online:
• Press and hold the FPC online/offline button until the green OK LED next to the button lights steadily, in about 5 seconds. The LEDs and online/offline button for each FPC are located directly above it on the craft interface.
• Issue the following CLI command: user@host> request chassis fpc slot slot-number online
CAUTION: After the OK LED lights steadily, wait at least 30 seconds before removing the FPC again, removing an FPC from a different slot, or inserting an FPC in a different slot.
You can also verify correct FPC and PIC functioning by issuing the show chassis fpc and show chassis fpc pic-status commands.
See Also •
T4000 FPC Description on page 57
• T4000 Craft Interface LEDs
Copyright © 2018, Juniper Networks, Inc.
Chapter 30: Replacing Line Card Components
•
Maintaining T4000 FPCs on page 337
•
Troubleshooting the T4000 FPCs on page 358
•
Prevention of Electrostatic Discharge Damage on page 423
Replacing a T4000 PIC
1.
Removing a T4000 PIC on page 301
2.
Installing a T4000 PIC on page 303
Removing a T4000 PIC
PICs are hot-insertable and hot-removable. When you remove a PIC, the router continues to function, although the PIC interfaces being removed no longer function.
The PICs are located in the FPCs installed in the front of the router. A PIC weighs approximately 2 lb (0.9 kg).
To remove a PIC (see
):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface to receive the
PIC. If the PIC connects to fiber-optic cable, have ready a rubber safety cap for each transceiver and cable.
2.
Attach an electrostatic discharge ESD grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Use one of the following methods to take the PIC offline:
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot offline
• Press and hold the online/offline button until the status LED on the PIC goes out
(about 5 seconds). The label for the status LED varies for each PIC. See the T4000
Core Router Interface Module Reference for more information about the PIC LEDs.
For a Type 4 or Type 5 PIC, use a narrow-ended tool that fits inside the opening that leads to the button.
4.
Label the cables connected to the PIC so that you can later reconnect each cable to the correct PIC.
5.
Disconnect the cables from the PIC. If the PIC uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
Copyright © 2018, Juniper Networks, Inc.
301
T4000 Core Router Hardware Guide
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
6.
Arrange the cable in the cable management system to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
7.
Type 4 or Type 5 PIC—To unseat the PIC, twist the ejector handle at the bottom of the PIC faceplate, then twist the ejector handle at the top of the faceplate counterclockwise to unseat the PIC.
8.
Slide the PIC out of the FPC card carrier, and place it in the electrostatic bag or on the antistatic mat.
9.
If you are not reinstalling a PIC into the emptied PIC slot within a short time, install a blank PIC panel over the slot to maintain proper airflow in the FPC card cage.
302 Copyright © 2018, Juniper Networks, Inc.
Figure 120: Removing a PIC
Chapter 30: Replacing Line Card Components
See Also •
T4000 PIC Description on page 62
•
Maintaining T4000 PICs on page 338
•
Troubleshooting the T4000 PICs on page 363
•
Prevention of Electrostatic Discharge Damage on page 423
Installing a T4000 PIC
To install a PIC (see
).
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
If the PIC uses fiber-optic cable, verify that there is a rubber safety cap over each transceiver on the faceplate. Install a cap if necessary.
Copyright © 2018, Juniper Networks, Inc.
303
T4000 Core Router Hardware Guide
3.
Align the notches in the connector at the rear of the PIC with the notches in the PIC slot in the FPC, and then slide the PIC in until it lodges firmly in the FPC.
CAUTION: Slide the PIC straight into the slot to avoid damaging the components on the bottom of the PIC.
4.
Type 4 or Type 5 PICs—To secure the PIC to the FPC faceplate, twist the ejector handle at the bottom of the PIC faceplate, then twist the ejector handle at the top of the faceplate counterclockwise to unseat the PIC.
5.
If the PIC uses fiber-optic cable, remove the rubber safety cap from each transceiver and the end of each cable.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
6.
Insert the appropriate cables into the cable connectors on the PIC.
7.
Arrange each cable in the cable management system to prevent the cable from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
8.
Use one of the following methods to bring the PIC online:
304 Copyright © 2018, Juniper Networks, Inc.
Chapter 30: Replacing Line Card Components
• Press the PIC offline/online button until the status LED on the PIC lights green. For a Type 4 or Type 5 PIC, use a narrow-ended tool that fits inside the opening that leads to the button.
For more information about the PIC LEDs, see the T4000 Core Router Interface
Module Reference .
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
The normal functioning status LED confirms that the PIC is online. You can also verify correct PIC functioning by issuing the show chassis fpc pic-status command.
Figure 121: Installing a PIC
See Also •
T4000 PIC Description on page 62
•
Maintaining T4000 PICs on page 338
Copyright © 2018, Juniper Networks, Inc.
305
T4000 Core Router Hardware Guide
•
Troubleshooting the T4000 PICs on page 363
•
Prevention of Electrostatic Discharge Damage on page 423
306 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 31
Replacing Power System Components
•
Replacing a T4000 Six-Input DC Power Supply on page 307
•
Replacing a T4000 Six-Input DC Power Supply Front Air Filter on page 312
•
Replacing a T4000 Six-Input DC Power Supply Side Air Filter on page 313
•
Replacing a T4000 DC Power Supply Cable on page 315
Replacing a T4000 Six-Input DC Power Supply
1.
Removing a T4000 Six-Input DC Power Supply on page 307
2.
Installing a T4000 Six-Input DC Power Supply on page 310
Removing a T4000 Six-Input DC Power Supply
To remove a six-input DC power supply:
1.
Switch off the customer site circuit breakers to the power supply being removed. Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during the removal process.
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on.
2.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
Copyright © 2018, Juniper Networks, Inc.
307
T4000 Core Router Hardware Guide
Figure 122: DC Power Supply
308
3.
Using a 7/16-in. (11 mm) nut driver, remove the nuts and washers from the terminal studs (see
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
Figure 123: Disconnecting Power Cables from the DC Power Supply
Cable lug
Terminal studs
Locking washer
Nut
4.
Remove the cable lugs from the terminal studs.
5.
Loosen the captive screws on the cable restraints on the right edge of the power supply faceplate.
6.
Carefully move the power cables out of the way.
7.
Loosen the captive screws on the lower corners of the power supply faceplate completely.
Copyright © 2018, Juniper Networks, Inc.
Chapter 31: Replacing Power System Components
8.
Twist the ejector handles on the upper corners of the faceplate counterclockwise to unseat the power supply.
9.
Grasp the handle on the power supply faceplate, and pull firmly. Slide it halfway out of the chassis (see
).
CAUTION: Each DC power supply weighs approximately 39.7 lb (18.0 kg).
Be prepared to support the full weight of the power supply as you remove it from the router.
10.
Place one hand underneath the power supply to support it, and slide it completely out of the chassis.
Figure 124: Removing a DC Power Supply
WARNING: Do not touch the power connectors on the rear of the power supply (see
). They can contain dangerous voltages.
Copyright © 2018, Juniper Networks, Inc.
309
T4000 Core Router Hardware Guide
Figure 125: Rear of the Power Supply Showing Midplane Connectors
Installing a T4000 Six-Input DC Power Supply
Each DC power supply weighs approximately 39.7 lb (18.0 kg). To install a six-input DC power supply:
1.
Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during installation.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Using both hands, slide the power supply into the chassis until you feel resistance
(see
).
Figure 126: Inserting the DC Power Supply into the Chassis
310
4.
Twist the ejector handles at the upper corners of the power supply faceplate clockwise until they stop.
Copyright © 2018, Juniper Networks, Inc.
Chapter 31: Replacing Power System Components
5.
Tighten the captive screws at the lower corners of the power supply faceplate to secure the power supply in the chassis.
6.
Verify that a licensed electrician has attached cable lugs to the power cables that you supply.
7.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
8.
Remove the nut and washer from each power terminal stud.
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
9.
Attach the lugs on the DC source power cables to the terminal studs.
a.
Attach the negative (–) DC source power cable lug to the –48V (input) terminal.
b.
Attach the positive (+) DC source power cable lug to the RTN (return) terminal.
Secure the cable lugs to the terminal studs, first with a washer, then with a nut (see
Figure 127 on page 311 ). Use a 7/16-in. (11 mm) nut driver to tighten the nut. Apply
between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
Figure 127: Attaching the DC Power Cable
Cable lug
Terminal studs
Locking washer
Nut
10.
Loosen the captive screws on the cable restraint on the right edge of the power supply faceplate.
Copyright © 2018, Juniper Networks, Inc.
311
T4000 Core Router Hardware Guide
11.
Route the DC power cables through the cable restraint.
12.
Tighten the cable restraint captive screws to hold the power cables in place.
13.
Verify that the power cabling is correct, that the power cables do not touch or block access to other hardware components, and that they do not drape where people could trip on them.
14.
Replace the clear plastic cover over the terminal studs on the faceplate.
15.
Switch on the customer site circuit breakers to provide voltage to the DC power source cables.
16.
Verify that the INPUT PRESENT LEDs on the power supply faceplate are lit steadily, indicating that the inputs are receiving power.
17.
Switch the power switch on the power supply to the ON position ( | ). The DC OK LED blinks momentarily, then lights steadily.
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the LEDs on the power supply, the command output displays, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
18.
Verify that the DC OK LED on the power supply faceplate is lit steadily, indicating that the power supply is correctly installed and is functioning properly.
Related
Documentation
•
T4000 Power System Description on page 75
•
T4000 Six-Input DC Power Supply LEDs on page 77
•
Maintaining the T4000 Power System on page 338
•
Troubleshooting the T4000 Power System on page 363
Replacing a T4000 Six-Input DC Power Supply Front Air Filter
1.
Removing a T4000 Six-Input DC Power Supply Front Air Filter on page 313
2.
Installing a T4000 Six-Input DC Power Supply Front Air Filter on page 313
312 Copyright © 2018, Juniper Networks, Inc.
Chapter 31: Replacing Power System Components
Removing a T4000 Six-Input DC Power Supply Front Air Filter
To remove a six-input DC power supply :
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the filter cover on the power supply faceplate, and pull it straight off the power supply.
3.
Remove the air filter.
Installing a T4000 Six-Input DC Power Supply Front Air Filter
To install a six-input DC power supply front filter element:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Install a new filter element.
3.
Press the filter cover straight onto the power supply faceplate until all four sides click into place.
See Also •
T4000 Cooling System Description on page 25
•
Routine Maintenance Procedures for the T4000 Router on page 331
•
Maintaining the T4000 Air Filters on page 334
•
Replacing a T4000 Six-Input DC Power Supply Side Air Filter on page 313
•
Prevention of Electrostatic Discharge Damage on page 423
Replacing a T4000 Six-Input DC Power Supply Side Air Filter
1.
Removing a T4000 Six-Input DC Power Supply Side Air Filter on page 313
2.
Installing a T4000 Six-Input DC Power Supply Side Air Filter on page 314
Removing a T4000 Six-Input DC Power Supply Side Air Filter
To remove a six-input DC power supply side air filter element:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Loosen the captive screw.
Copyright © 2018, Juniper Networks, Inc.
313
T4000 Core Router Hardware Guide
3.
Slide the air filter cover until the two lances leave the sheet metal.
4.
Remove the air filter cover hooks from the rectangle holes in the sheet metal.
5.
Remove the side air filter element from the air filter cover.
Figure 128: Removing the Power Supply Side Air Filter
Air filter cover
Air filter element
Installing a T4000 Six-Input DC Power Supply Side Air Filter
To install a six-input DC power supply side air filter element:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Install a new side filter element into the side air filter cover.
3.
Insert the side air filter cover hooks into the rectangle holes in the sheet metal.
4.
Slide the side air filter cover back into the power supply faceplate. The two lances insert into the sheet metal.
5.
Tighten the captive screw.
314 Copyright © 2018, Juniper Networks, Inc.
Chapter 31: Replacing Power System Components
Figure 129: Installing the Power Supply Side Air Filter
Air filter element
Air filter cover
See Also •
T4000 Cooling System Description on page 25
•
Routine Maintenance Procedures for the T4000 Router on page 331
•
Maintaining the T4000 Air Filters on page 334
•
Replacing a T4000 Six-Input DC Power Supply Front Air Filter on page 312
•
Prevention of Electrostatic Discharge Damage on page 423
Replacing a T4000 DC Power Supply Cable
1.
Removing a T4000 DC Power Supply Cable on page 315
2.
Installing a T4000 DC Power Supply Cable on page 316
Removing a T4000 DC Power Supply Cable
To remove a DC power supply cable from a six-input DC power supply:
1.
Switch off the customer site circuit breakers for all the cables attached to the power supply. Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during the removal process.
2.
Remove the power cable from the external DC power source.
3.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
4.
Remove the nut and washer from the terminal stud on the power supply (see
Figure 130 on page 316 ). Use a 7/16-in. (11 mm) nut driver.
Copyright © 2018, Juniper Networks, Inc.
315
T4000 Core Router Hardware Guide
Figure 130: Disconnecting the DC Power Cable
Cable lug
Terminal studs
Locking washer
Nut
5.
Remove the cable lug from the terminal stud on the power supply.
6.
Loosen the captive screw or screws on the cable restraint on the right edge of the power supply faceplate.
7.
Carefully move the power cable out of the way.
Installing a T4000 DC Power Supply Cable
To install a DC power supply cable on a six-input DC power supply:
1.
Locate a DC power cable that meets the specifications for the power supply.
CAUTION: A licensed electrician must attach a cable lug to the power cable that you supply. A cable with an incorrectly attached lug can damage the router.
2.
Route the power cable through the appropriate cable restraint.
3.
Attach the lug on the DC source power cable to the terminal stud.
a.
Attach a negative (–) DC source power cable lug to the –48V (input) terminals.
b.
Attach a positive (+) DC source power cable lug to the RET (return) terminals.
Secure the cable lug to the terminal stud, first with a washer, then with a nut (see
). Use a 7/16-in. (11-mm) nut driver to tighten the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
316 Copyright © 2018, Juniper Networks, Inc.
Figure 131: Connecting the DC Power Cable
Cable lug
Terminal studs
Locking washer
Nut
Chapter 31: Replacing Power System Components
4.
Tighten the cable restraint captive screw or screws to hold the power cable in place.
5.
Replace the clear plastic cover over the terminal studs on the faceplate.
6.
Verify that the DC source power cabling is correct, that the power cable is not touching or blocking access to router components, and that it does not drape where people could trip on it.
7.
Attach the other end of the power cable to the external DC power source.
8.
Switch on the customer site circuit breakers.
9.
Verify that the INPUT PRESENT LEDs on the power supply faceplate are lit steadily, indicating that the inputs are receiving voltage.
10.
Switch the power switch on the power supply to the ON position ( | ). The DC OK LED blinks momentarily, then lights steadily.
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the LEDs on the power supply, the command output displays, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
11.
Verify that the DC OK LED on the power supply faceplate is lit steadily, indicating that the power supply is correctly installed and is functioning properly.
Related
Documentation
•
T4000 Power System Description on page 75
•
T4000 Six-Input DC Power Supply LEDs on page 77
•
Maintaining the T4000 Power System on page 338
•
Troubleshooting the T4000 Power System on page 363
Copyright © 2018, Juniper Networks, Inc.
317
T4000 Core Router Hardware Guide
318 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 32
Replacing Switch Fabric Components
•
Replacing a T4000-SIB on page 319
•
Replacing a T4000 TXP-LCC-3D SIB on page 322
Replacing a T4000-SIB
Five SIBs are installed in the router. The SIBs are located in the rear of the chassis in the slots marked SIB0 through SIB4 . Each T4000 SIB weighs approximately 6.5 lb (3.0 kg).
1.
Removing a T4000-SIB on page 319
2.
Installing a T4000-SIB on page 320
Removing a T4000-SIB
To remove a SIB (see
):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Loosen the captive screws (using a Phillips (+) screwdriver, number 2) on the ejector handles on each side of the SIB faceplate.
4.
Flip the ejector handles outward to unseat the SIB.
5.
Grasp both ejector handles, pull firmly, and slide the SIB about three-quarters of the way out of the chassis.
6.
Place one hand underneath the SIB to support it, and slide it completely out of the chassis. Place it on the antistatic mat.
CAUTION: Do not stack hardware components on one another after you remove them. Place each component on an antistatic mat resting on a stable, flat surface.
Copyright © 2018, Juniper Networks, Inc.
319
T4000 Core Router Hardware Guide
Figure 132: Removing a T4000 SIB
Installing a T4000-SIB
To install a T4000-SIB (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Place one hand underneath the SIB to support it. With the other hand, hold one of the ejector handles on the SIB.
3.
Carefully align the sides of the SIB with the guides inside the chassis.
4.
Slide the SIB into the chassis, carefully ensuring that it is correctly aligned.
5.
Grasp both ejector handles, and press them inward to seat the SIB. Ensure that the ejector handle tabs are properly mated inside their corresponding chassis slots. You might have to close and open the handles a few times before the tabs catch the slots.
6.
Tighten the captive screws on the ejector handles.
7.
Bring the SIB online using one of the following methods:
• Press and hold the ONLINE/OFFLINE button on the SIB faceplate. The green OK
LED on the faceplate begins to blink. Hold the button down until the LED blinks.
320 Copyright © 2018, Juniper Networks, Inc.
Chapter 32: Replacing Switch Fabric Components
• Issue the following CLI command on the router: user@host> request chassis sib online slot 0
8.
Check the LEDs on the SIB faceplate.
• The green OK LED should light steadily a few minutes after the SIB is installed.
• If the FAIL LED is lit steadily, remove and install the SIB again. Make sure that the
SIB is seated properly. If the FAIL LED still lights steadily, the SIB is not functioning properly. Contact your customer support representative.
9.
Verify that four SIBs are in the Online state and one SIB is in the Spare state. Display the status of the SIB by issuing the show chassis sibs command: user@host> show chassis sibs
Slot State Uptime
0 Spare
1 Online 1 day, 13 hours, 16 minutes, 49 seconds
2 Online 1 day, 13 hours, 16 minutes, 33 seconds
3 Online 1 day, 13 hours, 16 minutes, 16 seconds
4 Online 1 day, 13 hours, 16 minutes
Figure 133: Installing a T4000 SIB
See Also •
Copyright © 2018, Juniper Networks, Inc.
321
T4000 Core Router Hardware Guide
Related
Documentation
•
T4000 Switch Interface Board (SIB) Description on page 79
•
T4000-SIB Description on page 80
•
Maintaining the T4000 SIBs on page 339
•
Troubleshooting the T4000 SIBs on page 368
•
Prevention of Electrostatic Discharge Damage on page 423
Replacing a T4000 TXP-LCC-3D SIB
Five SIBs are installed in the router. The SIBs are located in the rear of the chassis in the slots marked SIB0 through SIB4 .
Each TXP-LCC-3D SIB weighs approximately 9.4 lb (4.2 kg). The TXP-LCC-3D SIBs are connected to the TXP-F13-3D SIBs in a TX Matrix Plus router.
TXP-LCC-3D SIBs in active data switching planes are hot-pluggable. TXP-LCC-3D SIBs in a spare data switching planes are hot-insertable and hot-removable. When you remove a TXP-LCC-3D SIB in a spare switching plane, traffic forwarding continues without any degradation as long as the other four switching planes remain online. However, removing a TXP-LCC-3D SIB in an active switching plane might cause performance degradation in that switching plane. To avoid performance degradation, you can take the switching plane offline before you remove a TXP-LCC-3D SIB. For more information, see the TX
Matrix Plus Router Hardware Guide .
1.
Removing a T4000 TXP-LCC-3D SIB on page 322
2.
Installing a T4000 TXP-LCC-3D SIB on page 325
Removing a T4000 TXP-LCC-3D SIB
To remove a TXP-LCC-3D SIB:
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Ensure that the cables connected to the TXP-LCC-3D SIB are labeled so you can reconnect them correctly.
4.
Use one of the following methods to take the TXP-LCC-3D SIB offline:
• Issue the request chassis sib lcc number slot slot-number offline command. For example: user@host> request chassis sib lcc 0 slot 3 offline
Online initiated, use "show chassis sibs" to verify
322 Copyright © 2018, Juniper Networks, Inc.
Chapter 32: Replacing Switch Fabric Components
• Press and hold the SIB ONLINE/OFFLINE button in the middle of the TXP-LCC-3D
SIB faceplate to take the SIB offline. Hold the buttons down until all the LEDs on the faceplate are not lit.
5.
Remove each switching plane cable from the SIB.
•
CXP—Disconnect the CXP cables ( Figure 134 on page 324
) from the CXP transceivers.
After all the CXP cables have been disconnected from the transceivers, remove the
CXP transceivers ( Figure 135 on page 324
) from the SIB.
WARNING: Do not look directly into a CXP cable connected to a port.
The fiber optics emit laser light that can damage your eyes.
• AOC—Remove the AOC transceivers from the SIB (
).
6.
Install dust covers on the cables and transceivers that you removed. Align the dust cover with the cable or transceiver and carefully press them together until they stop.
The dust cover and the cable or transceiver are keyed to ensure proper mating.
• CXP—Install a dust cover on each CXP transceiver and CXP cable.
• AOC—Install a dust cover on each AOC transceiver.
7.
Move the cables to the side of the SIB so they do not interfere with the removal of the
SIB.
8.
Using a Phillips (+) screwdriver, number 2, loosen the captive screws on the ejector handles on each side of the SIB faceplate.
9.
Flip the ejector handles outward to unseat the SIB ( Figure 137 on page 325 ).
10.
Grasp both ejector handles, pull firmly, and slide the SIB about three-quarters of the way out of the chassis.
11.
Place one hand underneath the SIB to support it, and slide it completely out of the chassis. Place it on the antistatic mat.
CAUTION: Do not stack hardware components on one another after you remove them. Place each component on an antistatic mat resting on a stable, flat surface.
Copyright © 2018, Juniper Networks, Inc.
323
T4000 Core Router Hardware Guide
Figure 134: CXP Cable and Dust Cover
CXP switching plane cable CXP switching plane cable with dust cover
Figure 135: CXP Transceiver and Dust Cover
CXP transceiver
CXP transceiver with dust cover
Figure 136: AOC Transceiver and Dust Cover
AOC switching plane cable and transceiver
AOC switching plane cable and transceiver with dust cover
324 Copyright © 2018, Juniper Networks, Inc.
Figure 137: Removing a TXP-LCC-3D SIB
Chapter 32: Replacing Switch Fabric Components
Installing a T4000 TXP-LCC-3D SIB
To install a TXP-LCC-3D SIB:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Place one hand underneath the SIB to support it. With the other hand, hold one of the ejector handles on the SIB.
3.
Carefully align the sides of the SIB with the guides inside the chassis.
4.
Slide the SIB into the chassis, carefully ensuring that it is correctly aligned
(
).
5.
Grasp both ejector handles, and press them inward to seat the SIB. Ensure that the ejector handle tabs are properly mated inside their corresponding chassis slots. You might have to close and open the handles a few times before the tabs catch the slots.
6.
Tighten the captive screws on the ejector handles.
7.
Remove the dust covers from the transceivers and cables. Store the dust covers in a dust-free resealable plastic bag.
Copyright © 2018, Juniper Networks, Inc.
325
T4000 Core Router Hardware Guide
8.
Insert the transceiver into the ports.
• CXP—Insert the CXP transceivers into the TXP-LCC-3D ports. The CXP transceivers and the port are keyed to ensure proper mating. After all the CXP transceiver have
been installed, reconnect each CXP cable ( Figure 139 on page 327
) to the CXP transceiver in the TXP-LCC-3D port that corresponds to the label on the cable.
Align the cable with the port and carefully press it into the port until it your hear a click and it stops. The CXP cables and CXP transceivers are keyed to ensure proper mating.
• AOC—Using the cable labels, insert each AOC transceiver into its corresponding
TXP-F13-3D port ( Figure 140 on page 328 ).
Align the transceiver with the port and carefully press it into the port until it your hear a click and it stops. The AOC transceivers and the port are keyed to ensure proper mating.
9.
Bring the TXP-LCC-3D SIB online using one of the following methods:
• Press and hold the ONLINE/OFFLINE button on the TXP-LCC-3D SIB faceplate. The green OK LED on the faceplate begins to blink. Hold the button down until the LED blinks.
• Issue the following CLI command on the router: user@host> request chassis sib online slot 0
10.
Check the LEDs on the TXP-LCC-3D SIB faceplate.
• The green OK LED should light steadily a few minutes after the SIB is installed.
• If the FAIL LED is lit steadily, remove and install the TXP-LCC-3D SIB again. Make sure that the SIB is seated properly. If the FAIL LED still lights steadily, the SIB is not functioning properly. Contact your customer support representative.
11.
Verify that four SIBs are in the Online state and one SIB is in the Spare state. Display the status of the SIB by issuing the show chassis sibs command: user@host> show chassis sibs
Slot State Uptime
0 Spare
1 Online 1 day, 13 hours, 16 minutes, 49 seconds
2 Online 1 day, 13 hours, 16 minutes, 33 seconds
3 Online 1 day, 13 hours, 16 minutes, 16 seconds
4 Online 1 day, 13 hours, 16 minutes
If a SIB is not online, issue the request chassis sib online operational mode command.
326 Copyright © 2018, Juniper Networks, Inc.
Figure 138: Installing a TXP-LCC-3D SIB
Chapter 32: Replacing Switch Fabric Components
Figure 139: Connecting a CXP Cable to a CXP Transceiver
TXP-LCC-3D
SIB
CXP transceiver
CXP cable
Copyright © 2018, Juniper Networks, Inc.
327
T4000 Core Router Hardware Guide
Figure 140: Installing an AOC Transceiver
AOC transceiver
TXP-LCC-3D
SIB
Related
Documentation
•
T4000 Switch Interface Board (SIB) Description on page 79
•
T4000 TXP-LCC-3D SIB Description on page 80
•
Maintaining the T4000 SIBs on page 339
•
Troubleshooting the T4000 SIBs on page 368
•
Prevention of Electrostatic Discharge Damage on page 423
328 Copyright © 2018, Juniper Networks, Inc.
PART 5
Maintaining the Chassis and Components
•
Routine Maintenance Procedures on page 331
•
Maintaining Components on page 333
•
Powering Off the Router on page 341
Copyright © 2018, Juniper Networks, Inc.
329
T4000 Core Router Hardware Guide
330 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 33
Routine Maintenance Procedures
•
Routine Maintenance Procedures for the T4000 Router on page 331
Routine Maintenance Procedures for the T4000 Router
Purpose For optimum router performance, perform preventive maintenance procedures.
Action On a regular basis:
• Inspect the installation site for moisture, loose wires or cables, and excessive dust.
Make sure that airflow is unobstructed around the router and into the air intake vents.
• Check the status-reporting devices on the craft interface: system alarms, LEDs, and
LCD.
• Inspect the air filters at the bottom front and left rear of the router. Do not run the router for more than a few minutes without the air filters in place.
Check the air filters regularly for dust and debris. As a general guideline, we recommended that you replace the filter elements every 6 months for routers operating in a typical environment. The filter elements degrade over time, and replacement intervals will vary by operating environment.
Related
Documentation
•
T4000 Cooling System Description on page 25
•
T4000 Craft Interface Description on page 16
•
Maintaining the T4000 Air Filters on page 334
Copyright © 2018, Juniper Networks, Inc.
331
T4000 Core Router Hardware Guide
332 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 34
Maintaining Components
•
Tools and Parts Required to Maintain the T4000 Hardware Components on page 333
•
Maintaining the T4000 SCGs on page 333
•
Maintaining the T4000 Air Filters on page 334
•
Maintaining the T4000 Fan Trays on page 335
•
Maintaining the T4000 Host Subsystem on page 335
•
Maintaining the T4000 Routing Engines on page 336
•
Maintaining the T4000 Control Boards on page 337
•
Maintaining T4000 FPCs on page 337
•
Maintaining T4000 PICs on page 338
•
Maintaining the T4000 Power System on page 338
•
Maintaining the T4000 SIBs on page 339
Tools and Parts Required to Maintain the T4000 Hardware Components
To maintain the hardware components, you need the following tools and parts:
• ESD grounding wrist strap
• Flat-blade (–) screwdriver
• Phillips (+) screwdriver, number 1
• Phillips (+) screwdriver, number 2
Related
Documentation
•
Routine Maintenance Procedures for the T4000 Router on page 331
Maintaining the T4000 SCGs
Purpose For optimum router performance, verify the condition of the SCGs.
Copyright © 2018, Juniper Networks, Inc.
333
T4000 Core Router Hardware Guide
Action On a regular basis:
• Check the SCG LEDs. During normal operations:
• The green OK LED on the SCG faceplate is lit.
• The yellow FAIL LED on the SCG faceplate is not lit. If the yellow FAIL LED is lit, see
“Troubleshooting the T4000 SCGs” on page 349 .
• Use the show chassis environment scg command to verify the status of the SCGs.
Related
Documentation
•
T4000 SONET Clock Generators (SCGs) Description on page 20
•
T4000 SONET Clock Generators (SCGs) LEDs on page 22
Maintaining the T4000 Air Filters
Purpose For optimum cooling, verify the condition of the air filters.
Air filters for both the front and rear fan trays help keep dust and other particles from entering the cooling system. To function properly, the entire cooling system requires an unobstructed airflow and proper clearance around the site, as described in
Clearance Requirements for Airflow and Hardware Maintenance” on page 91 . See
Figure 141: Airflow Through the Chassis
334
Action Check the air filters regularly for dust and debris. As a general guideline, we recommended that you replace the filter elements every 6 months for routers operating in a typical environment. The filter elements degrade over time, and replacement intervals will vary by operating environment.
Copyright © 2018, Juniper Networks, Inc.
Chapter 34: Maintaining Components
For procedures to replace the air filters, see the following topics:
•
Replacing a T4000 Rear Air Filter on page 261
•
Replacing a T4000 Front Air Filter on page 259
•
Replacing a T4000 Six-Input DC Power Supply Front Air Filter on page 312
•
Replacing a T4000 Six-Input DC Power Supply Side Air Filter on page 313
The shelf life of polyurethane filter varies from two years to five years depending on the storage conditions. Store in a cool, dry, and dark environment. Wrap the media in plastic and store in an environment with relative humidity between 40%- 80% and temperature between 40°F (4° C) to 90°F (32° C). Note that if the material flakes, or becomes brittle when rubbed or deformed, it is no longer usable.
CAUTION: Always keep the air filters in place while the router is operating.
Because the fans are very powerful, they could pull small bits of wire or other materials into the router through the unfiltered air intake. This could damage the router components.
Related
Documentation
•
T4000 Cooling System Description on page 25
•
Maintaining the T4000 Fan Trays on page 335
•
Troubleshooting the T4000 Cooling System on page 351
Maintaining the T4000 Fan Trays
Purpose For optimum cooling, verify the condition of the fans.
Action On a regular basis, monitor the status of the fans. The fan trays each contain multiple fans that work in unison to cool the router components. During normal operation, the status of each fan is OK , and the fans in each fan tray function at normal speed. Use the show chassis environment and show chassis fan commands to verify the status of the fans.
Related
Documentation
•
T4000 Cooling System Description on page 25
•
Maintaining the T4000 Air Filters on page 334
•
Troubleshooting the T4000 Cooling System on page 351
Maintaining the T4000 Host Subsystem
Purpose For optimum router performance, verify the condition of the Routing Engines and the control boards.
Copyright © 2018, Juniper Networks, Inc.
335
T4000 Core Router Hardware Guide
Action Each host subsystem comprises a Routing Engine and an adjacent control board functioning together. To maintain the host subsystem:
• Check the host subsystem LEDs ( HOST0 and HOST1 ) on the craft interface. During normal operations:
• The green host subsystem OK LED on the craft interface is lit.
• The red host subsystem FAIL LED on the craft interface is not lit.
If the red HOST0 FAIL or HOST1 FAIL LED is lit, see
“Troubleshooting the T4000 Host
• Check the LEDs on the control board. See
“Maintaining the T4000 Control Boards” on page 337 .
• Check the LEDs on the Routing Engine. See
“Maintaining the T4000 Routing Engines” on page 336
Related
Documentation
• T4000 Craft Interface LEDs
•
T4000 LCC-CB Control Board LEDs on page 31
•
T4000 RE-C1800 LEDs on page 35
Maintaining the T4000 Routing Engines
Purpose For optimum router performance, verify the condition of the Routing Engines.
Action On a regular basis:
• Check the host subsystem LEDs ( HOST0 and HOST1 ) on the craft interface. During normal operations:
• The green host subsystem OK LED on the craft interface is lit.
• The red host subsystem FAIL LED on the craft interface is not lit.
If the red HOST0 FAIL or HOST1 FAIL LED is lit, see
“Troubleshooting the T4000 Host
• Check the LEDs on the Routing Engine. During normal operation, the ONLINE LED on each Routing Engine is lit green, indicating that the Routing Engine is functional.
• Check the LCD on the craft interface to view information about the router temperature and the status of the Routing Engines.
• Use the show chassis routing-engine command to check the status of the Routing
Engines.
Related
Documentation
• T4000 Craft Interface LEDs
•
T4000 RE-C1800 LEDs on page 35
336 Copyright © 2018, Juniper Networks, Inc.
Chapter 34: Maintaining Components
•
Maintaining the T4000 Host Subsystem on page 335
•
Maintaining the T4000 Control Boards on page 337
•
Troubleshooting the T4000 Routing Engines on page 355
Maintaining the T4000 Control Boards
Purpose For optimum router performance, verify the condition of the control boards.
Action On a regular basis:
• Check the LEDs on the control board faceplate. During normal operations:
• The green OK LED on the control board faceplate is lit.
• The yellow FAIL LED on the control board faceplate is not lit. if the FAIL is lit, see
“Troubleshooting the T4000 Host Subsystems” on page 354
and
“Troubleshooting the T4000 Control Boards” on page 356 .
• Check the host subsystem LEDs ( HOST0 and HOST1 ) on the craft interface. During normal operations:
• The green host subsystem OK LED on the craft interface is lit.
• The red host subsystem FAIL LED on the craft interface is not lit.
If the red HOST0 FAIL or HOST1 FAIL LED is lit, see
“Troubleshooting the T4000 Host
and
“Troubleshooting the T4000 Control Boards” on page 356 .
• Use the show chassis environment cb command to check the status of the control boards. During normal operations, the control board is online .
Related
Documentation
•
T4000 LCC-CB Control Board LEDs on page 31
•
Maintaining the T4000 Host Subsystem on page 335
•
Maintaining the T4000 Routing Engines on page 336
Maintaining T4000 FPCs
Purpose For optimum router performance, verify the condition of the FPCs. The router can have up to eight FPCs mounted vertically in the FPC card cage at the front of the chassis.
Copyright © 2018, Juniper Networks, Inc.
337
T4000 Core Router Hardware Guide
Action On a regular basis:
• Check the LEDs on the craft interface directly above each FPC slot. During normal operation:
• The green OK LED above the FPC on the craft interface lights steadily when the FPC is online and functioning normally.
• The green OK LED blinks during startup.
• The red FAIL LED above the FPC on the craft interface is not lit. If the FAIL is lit, see
“Troubleshooting the T4000 FPCs” on page 358 .
• Check the LCD on the craft interface.
• Use the show chassis fpc command to verify the status of installed FPCs. The value
Online in the column labeled State indicates that the FPC is functioning normally.
Related
Documentation
• T4000 Craft Interface LEDs
•
T4000 FPC Description on page 57
Maintaining T4000 PICs
Purpose For optimum router performance, verify the condition of the PICs.
Action On a regular basis:
• Check the LEDs on PIC faceplates. A PIC LED lit green indicates the PIC is functioning normally.
The meaning of the LED states differs for various PICs. For more information, see the
T4000 Core Router Interface Module Reference . If the FPC that houses the PIC detects a PIC failure, the FPC generates an alarm message to be sent to the Routing Engine.
• Use the show chassis fpc pic-status command or show chassis pic comand. The PIC slots in an FPC are numbered from 0 through 1 , top to bottom:
Related
Documentation
•
T4000 PIC Description on page 62
•
Troubleshooting the T4000 PICs on page 363
Maintaining the T4000 Power System
Purpose For optimum router performance, verify the condition of the power supplies and grounding.
Action On a regular basis:
• Check the red and yellow alarm LEDs and the LCD on the craft interface. Power supply failure or removal triggers an alarm that causes one or both of the LEDs to light and
338 Copyright © 2018, Juniper Networks, Inc.
Chapter 34: Maintaining Components an error message to appear on the LCD. You can display the associated error messages by issuing the following CLI command: user@host> show chassis alarms
For a list of possible alarm messages, see
“Troubleshooting the T4000 Power System” on page 363 .
• Make sure that the DC power cables are arranged so that they do not obstruct access to other router components.
• The power supplies require an unobstructed airflow at both the front and rear of the chassis. Periodically check the site to ensure that both the air intake at the bottom front of the chassis and the exhaust from the power supply faceplates are unobstructed.
• Periodically inspect the site to ensure that the grounding and power cables connected to the router are securely in place and that no moisture is accumulating near the router.
To review grounding and site wiring requirements for the router, see
Cable and Lugs Specifications” on page 105
and
“T4000 Chassis Grounding Cable and
Lug Specifications” on page 90
.
• Use the show chassis environment pem command to verify the status of the power supplies.
• Routinely check the status LEDs on the power supply faceplates to verify that the power supplies are functioning normally. During normal operation:
• The blue DC OK LEDs light to indicate that the power supplies are functioning normally.
• Each green INPUT PRESENT LED on a DC power supply lights when the input is receiving source DC power.
Related
Documentation
•
T4000 Power System Description on page 75
•
T4000 Six-Input DC Power Supply LEDs on page 77
Maintaining the T4000 SIBs
Purpose For optimum router performance, verify the condition of the SIBs.
Action On a regular basis:
• Check the LEDs on the SIB faceplate and on the craft interface. During normal operations:
• The green OK LED is lit.
• The red FAIL LED is not lit. If the red FAIL is lit, see
“Troubleshooting the T4000 SIBs” on page 368
.
• Use the show chassis environment sib command to verify the status of the SIBs.
Copyright © 2018, Juniper Networks, Inc.
339
T4000 Core Router Hardware Guide
Related
Documentation
•
T4000 Switch Interface Board (SIB) Description on page 79
• T4000 Craft Interface LEDs
•
340 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 35
Powering Off the Router
•
Powering Off the T4000 Router on page 341
Powering Off the T4000 Router
To power off a T4000 router:
1.
On the external management device connected to the Routing Engine, issue the request system halt operational mode command. The command shuts down both
Routing Engines cleanly, so their state information is preserved. (If the router contains only one Routing Engine, issue the request system halt command.) user@host> request system halt both-routing-engines
2.
Wait until a message appears on the console confirming that the operating system has halted.
Halt the system ? [yes,no] (no) yes
*** FINAL System shutdown message from root@section2 ***
System going down IMMEDIATELY
Terminated
...
syncing disks... 11 8 done
The operating system has halted.
Please press any key to reboot.
3.
Switch off the external customer site circuit breakers to the power supplies.
Related
Documentation
•
Powering On the T4000 Router on page 207
• request system halt
Copyright © 2018, Juniper Networks, Inc.
341
T4000 Core Router Hardware Guide
342 Copyright © 2018, Juniper Networks, Inc.
PART 6
Troubleshooting Hardware
•
Troubleshooting Components on page 345
Copyright © 2018, Juniper Networks, Inc.
343
T4000 Core Router Hardware Guide
344 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 36
Troubleshooting Components
•
T4000 Troubleshooting Resources Overview on page 345
•
T4000 LED Overview on page 346
•
T4000 Alarm Messages Overview on page 347
•
Troubleshooting the T4000 Craft Interface on page 349
•
Troubleshooting the T4000 SCGs on page 349
•
Troubleshooting the T4000 Cooling System on page 351
•
Troubleshooting the T4000 Host Subsystems on page 354
•
Troubleshooting the T4000 Routing Engines on page 355
•
Troubleshooting the T4000 Control Boards on page 356
•
Troubleshooting the T4000 FPCs on page 358
•
Troubleshooting the T4000 PICs on page 363
•
Troubleshooting the T4000 Power System on page 363
•
Troubleshooting the T4000 SIBs on page 368
T4000 Troubleshooting Resources Overview
To troubleshoot a T4000 router, you use the Junos OS command-line interface (CLI),
LCD, alarms, devices connected to the alarm relay contacts, and LEDs on both the components and craft interface.
• LEDs—When the Routing Engine detects an alarm condition, it lights the red or yellow alarm LED on the craft interface as appropriate. In addition, you can also use the component-specific LEDs on the craft interface and on the faceplate of a component to troubleshoot the router.
• LCD—When a red or yellow alarm occurs, the cause of the alarm messages is displayed on the craft interface LCD. Use the CLI to display more information about the alarm.
• Alarm devices connected to the alarm relay contact—When a red or yellow alarm occurs, it trips the corresponding alarm relay contact.
• CLI—The CLI is the primary tool for controlling and troubleshooting hardware, Junos
OS, routing protocols, and network connectivity. CLI commands display information from routing tables, information specific to routing protocols, and information about network connectivity derived from the ping and traceroute utilities. For information
Copyright © 2018, Juniper Networks, Inc.
345
T4000 Core Router Hardware Guide about using the CLI to troubleshoot Junos OS, see the appropriate Junos OS configuration guide.
• JTAC—If you need assistance during troubleshooting, you can contact the Juniper
Networks Technical Assistance Center (JTAC) by using the Web or by telephone. If you encounter software problems, or problems with hardware components not discussed here, contact JTAC.
Related
Documentation
•
T4000 Craft Interface Description on page 16
• T4000 Craft Interface LEDs
•
T4000 Connector Interface Panel (CIP) Description on page 14
•
T4000 LED Overview on page 346
•
T4000 Alarm Messages Overview on page 347
•
Contacting Customer Support on page 375
T4000 LED Overview
•
Craft Interface LEDs on page 346
•
Craft Interface LEDs
The craft interface displays system status messages and allows you to troubleshoot the router. See T4000 Craft Interface LEDs .
LEDs on the craft interface include:
• Red and yellow alarm LEDs
• FPC LEDs
• Host subsystem LEDs
• SIB LEDs
Component LEDs
The following LEDs are located on various router components and display the status of those components:
• Control board LEDs
See
“T4000 LCC-CB Control Board LEDs” on page 31
• Routing Engine LEDs
See
“T4000 RE-C1800 LEDs” on page 35
.
• PIC LEDs
See T4000 Core Router Interface Module Reference .
346 Copyright © 2018, Juniper Networks, Inc.
Chapter 36: Troubleshooting Components
• Power Supply LEDs
See
“T4000 Six-Input DC Power Supply LEDs” on page 77
.
• SIB LEDs
See
• SCG LEDs
See
“T4000 SONET Clock Generators (SCGs) LEDs” on page 22 .
Related
Documentation
•
T4000 Hardware Component Overview on page 5
•
T4000 Troubleshooting Resources Overview on page 345
•
T4000 Alarm Messages Overview on page 347
T4000 Alarm Messages Overview
When the Routing Engine detects an alarm condition, it lights the red or yellow alarm
LED on the craft interface as appropriate, trips the corresponding alarm relay contact, and reports the cause of the alarm in the craft interface LCD.
To view a more detailed description of the alarm cause, issue the show chassis alarms
CLI command: user@host> show chassis alarms
1 alarms currently active
Alarm time Class Description
2011-12-08 21:05:15 PST Minor PEM 1 Absent
There are two classes of alarm messages:
•
•
Chassis Alarms
Chassis alarms Indicate a problem with a chassis component such as the cooling system or power supplies. For more information about chassis alarms for each component, see the following topics:
•
Troubleshooting the T4000 Cooling System on page 351
•
Troubleshooting the T4000 Craft Interface on page 349
•
Troubleshooting the T4000 Control Boards on page 356
•
Troubleshooting the T4000 FPCs on page 358
•
Troubleshooting the T4000 Host Subsystems on page 354
•
Troubleshooting the T4000 PICs on page 363
•
Troubleshooting the T4000 Power System on page 363
Copyright © 2018, Juniper Networks, Inc.
347
T4000 Core Router Hardware Guide
•
Troubleshooting the T4000 Routing Engines on page 355
•
Troubleshooting the T4000 SCGs on page 349
•
Troubleshooting the T4000 SIBs on page 368
Interface Alarms
Interface alarms Indicate a problem with a specific network interface, as described in
.
In
Table 80 on page 348 , the text in the column labeled “LCD Message” appears in the
LCD. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
Table 80: SONET/SDH Interface Alarm Messages
LCD Message CLI Message interface-name sox / x / x BERR-SD interface-name sox / x / x BERR-SF interface-name sox / x / x LAIS interface-name sox / x / x LOF interface-name sox / x / x LOL interface-name sox / x / x LOP interface-name sox / x / x LOS interface-name sox / x / x LRDI interface-name sox / x / x PAIS interface-name sox / x / x PLL interface-name sox / x / x PMIS interface-name sox / x / x PRDI interface-name sox / x / x REI interface-name sox / x / x SEF interface-name sox / x / x UNEQ interface-name sox / x / x - SONET bit error rate defect interface-name sox / x / x - SONET bit error rate fault interface-name sox / x / x - SONET line AIS interface-name sox / x / x - SONET loss of frame interface-name sox / x / x - SONET loss of light interface-name sox / x / x - SONET loss of pointer interface-name sox / x / x - SONET loss of signal interface-name sox / x / x - SONET line remote defect indicator interface-name sox / x / x - SONET path AIS interface-name sox / x / x - SONET PLL lock interface-name sox / x / x - SONET path mismatch interface-name sox / x / x - SONET path remote defect indicator interface-name sox / x / x - SONET remote error indicator interface-name sox / x / x - SONET severely errored frame interface-name sox / x / x - SONET unequipped
348 Copyright © 2018, Juniper Networks, Inc.
Chapter 36: Troubleshooting Components
Related
Documentation
•
T4000 Connector Interface Panel (CIP) Description on page 14
•
T4000 Craft Interface Description on page 16
Troubleshooting the T4000 Craft Interface
Problem Description:
The following alarms, LEDs, and other conditions indicate a problem with the craft interface:
• The router is powered on, but none of the LEDs on the craft interface are lit.
• A yellow alarm indicates that the craft interface has failed.
In
, the text in the column labeled ”LCD Message” appears in the display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
Table 81: Chassis Alarm Messages for the Craft Interface
Alarm Type LCD Message CLI Message
Yellow Craft Failure Craft Failure
Solution To troubleshoot the craft interface:
1.
Check the LEDs on the craft interface. If the router is powered on but none of the LEDs are lit, reseat the craft interface to make sure that it is installed properly. See
“Replacing a T4000 Craft Interface” on page 249
.
2.
Use the CLI to check for alarms. Use the show chassis alarms command.
Related
Documentation
•
T4000 Craft Interface Description on page 16
• T4000 Craft Interface LEDs
Troubleshooting the T4000 SCGs
Problem Description:
The following alarms and LEDs indicate a problem with an SCG:
• The yellow FAIL LED on the SCG faceplate is lit.
• The green OK LED on the SCG faceplate is not lit.
• A red alarm indicates that the SCG has failed or has been removed.
• A yellow alarm indicates that the SCG is not online.
Copyright © 2018, Juniper Networks, Inc.
349
T4000 Core Router Hardware Guide
350
In
Table 82 on page 350 , the text in the column labeled ”LCD Message” appears in the
display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
Table 82: Chassis Alarm Messages for the SCGs
Alarm Type LCD Message CLI Message
Red
Yellow
SCG SCG-number
Failure
SCG SCG-number
Removed
SCG
SCG
SCG-number Failure
SCG-number Removed
SCG SCG-number Not
Online
SCG SCG-number Not Online
Solution To troubleshoot the SCGs:
1.
Check the LEDs on the faceplate of each SCG.
2.
Check the LEDs on the craft interface.
3.
Use the show chassis environment scg command.
user@host> show chassis environment scg
SCG 0 status:
State Online - Master clock
Temperature 31 degrees C / 87 degrees F
Power:
GROUND 0 mV
3.3 V 3310 mV
5.0 V 5052 mV
5.6 V 5689 mV
1.8 V bias 1782 mV
3.3 V bias 3306 mV
5.0 V bias 4989 mV
8.0 V bias 8336 mV
GBUS Revision 40
FPGA Revision 1.6
4.
Use the CLI to check for alarms—Issue the show chassis alarms command to view the alarms.
Related
Documentation
•
T4000 SONET Clock Generators (SCGs) Description on page 20
•
T4000 SONET Clock Generators (SCGs) LEDs on page 22
•
Maintaining the T4000 SCGs on page 333
•
Replacing a T4000 SCG on page 256
Copyright © 2018, Juniper Networks, Inc.
Chapter 36: Troubleshooting Components
Troubleshooting the T4000 Cooling System
Problem Description:
The following alarms, LEDs, and other conditions indicate a problem with the cooling system:
• A red alarm indicates that the temperature of the router exceeds the maximum
(“temperature hot”) threshold.
• Automatic shutdown of the power supplies can be caused by the temperature of the router exceeding the maximum (“temperature hot”) threshold. The control board turns off the power supplies because the router temperature exceeds the acceptable maximum.
• A red alarm indicates that a fan failed.
• A yellow alarm indicates that the router temperature exceeds the “temperature warm” threshold.
• A yellow alarm indicates that one of the fan trays was removed.
• One or more fans in a fan tray function at full speed. The control boards constantly monitor the temperatures detected by sensors on the midplane and router components, adjusting the speed of the fans as necessary. If one fan fails, the host subsystem adjusts the speed of the remaining fans to maintain proper cooling.
Table 83: T4000 Cooling System Fan Tray Alarms
Alarm
Type LCD Message CLI Message Alarm Condition Solution
Red
Yellow
Fan Failure
Fans Missing
<fan-name> Improper <fan-name>
Improper for
Platform
Fan Removed fan-name Failure
Too many fans missing or failing
A fan has failed.
Replace the fan tray.
A fan tray is missing or too many fan trays have failed.
Reinstall the fan tray in the chassis.
A fan tray is unsupported for the
T4000 router.
Replace with an appropriate fan tray.
For a list of supported fan trays, see
.
Incompatible rear fan tray or front fan tray detected
An incompatible fan tray is inserted into the chassis.
Replace with an appropriate fan tray.
fan-name Removed A fan tray has been removed.
Reinstall the fan tray in the chassis.
Copyright © 2018, Juniper Networks, Inc.
351
T4000 Core Router Hardware Guide
Table 84: T4000 Temperature Alarms
Alarm
Type
Craft Interface LCD
Message CLI Message
Red Temperature Hot
Yellow
Sensor Failure
Temperature Warm
Alarm Condition Solution
Temperature Hot The chassis temperature exceeded the recommend hot temperature threshold. If this condition persists, the router shuts down.
• Place your hand near the exhaust vents at the rear of the chassis to determine whether the fans are pushing air out of the chassis.
Verify that the room temperature is within acceptable limits.
•
•
Verify that there is sufficient air flow.
Verify that the cooling system in the chassis is operating properly.
Temperature sensor failure
A temperature sensor failed.
Contact JTAC.
Temperature Warm The chassis temperature exceeded the recommended warm temperature threshold.
•
•
Place your hand near the exhaust vents at the rear of the chassis to determine whether the fans are pushing air out of the chassis.
Verify that the room temperature is within acceptable limits.
•
•
Verify that there is sufficient air flow.
Verify that the cooling system in the chassis is operating properly.
Solution To troubleshoot the cooling system:
1.
Check the red and yellow alarm LEDs on the craft interface.
2.
Find the source of the problem by looking at the craft interface display. The number of alarm conditions, as well as the source of each alarm, appears on the screen. If the craft interface display lists only one fan failure and the other fans are functioning normally, the fan is probably faulty and you need to replace the fan tray.
3.
Use the show chassis alarms command to get information about the source of an alarm condition: user@host> show chassis alarms
For information about the alarms, see
and
4.
Use the show chassis fan command to verify that the status of each fan is OK and that the output display indicates that each of the fans are Spinning at normal speed .
user@host> show chassis fan
Item Status RPM Measurement
Top Left Front fan OK 3420 Spinning at normal speed
352 Copyright © 2018, Juniper Networks, Inc.
Chapter 36: Troubleshooting Components
Top Left Middle fan OK 3420 Spinning at normal speed
Top Left Rear fan OK 3450 Spinning at normal speed
Top Right Front fan OK 3420 Spinning at normal speed
Top Right Middle fan OK 3420 Spinning at normal speed
Top Right Rear fan OK 3420 Spinning at normal speed
Bottom Left Front fan OK 3420 Spinning at normal speed
Bottom Left Middle fan OK 3450 Spinning at normal speed
Bottom Left Rear fan OK 3360 Spinning at normal speed
Bottom Right Front fan OK 3420 Spinning at normal speed
Bottom Right Middle fan OK 3420 Spinning at normal speed
Bottom Right Rear fan OK 3420 Spinning at normal speed
Rear Tray Top fan OK 5190 Spinning at normal speed
Rear Tray Second fan OK 5190 Spinning at normal speed
Rear Tray Third fan OK 5190 Spinning at normal speed
Rear Tray Fourth fan OK 5190 Spinning at normal speed
Rear Tray Fifth fan OK 5190 Spinning at normal speed
Rear Tray Sixth fan OK 5190 Spinning at normal speed
Rear Tray Seventh fan OK 5190 Spinning at normal speed
Rear Tray Bottom fan OK 5190 Spinning at normal speed
The fans in the fan trays are listed as follows:
• Upper front fan tray— Top Left and Top Right
• Lower front fan tray— Bottom Left and Bottom Right
• Rear fan tray— Rear
5.
Use the show chassis environment command to check the status and speed of the fans.
user@host> show chassis environment
Class Item Status Measurement
...
Fans Top Left Front fan OK Spinning at normal speed
Top Left Middle fan OK Spinning at normal speed
Top Left Rear fan OK Spinning at normal speed
Top Right Front fan OK Spinning at normal speed
Top Right Middle fan OK Spinning at normal speed
Top Right Rear fan OK Spinning at normal speed
Bottom Left Front fan OK Spinning at normal speed
Bottom Left Middle fan OK Spinning at normal speed
Bottom Left Rear fan OK Spinning at normal speed
Bottom Right Front fan OK Spinning at normal speed
Bottom Right Middle fan OK Spinning at normal speed
Bottom Right Rear fan OK Spinning at normal speed
Rear Tray Top fan OK Spinning at normal speed
Rear Tray Second fan OK Spinning at normal speed
Rear Tray Third fan OK Spinning at normal speed
Rear Tray Fourth fan OK Spinning at normal speed
Rear Tray Fifth fan OK Spinning at normal speed
Rear Tray Sixth fan OK Spinning at normal speed
Rear Tray Seventh fan OK Spinning at normal speed
Rear Tray Bottom fan OK Spinning at normal speed...
Top Left and Top Right refer to fans in the upper front fan tray.
Bottom Left and Bottom
Right refer to fans in the lower front fan tray.
Rear refers to the fans in the rear fan tray.
Copyright © 2018, Juniper Networks, Inc.
353
T4000 Core Router Hardware Guide
Related
Documentation
•
T4000 Cooling System Description on page 25
•
Replacing a T4000 Lower Front Fan Tray on page 265
•
Replacing a T4000 Upper Front Fan Tray on page 267
•
Replacing a T4000 Rear Fan Tray on page 269
•
Replacing a T4000 Front Air Filter on page 259
•
Replacing a T4000 Rear Air Filter on page 261
Troubleshooting the T4000 Host Subsystems
Problem Description:
The following alarms and LEDs indicate a problem with a host subsystem control board and Routing Engine:
• The red host subsystem FAIL LED on the craft interface is lit.
• The green host subsystem OK LED on the craft interface is not lit.
• A red alarm indicates that the host subsystem has been removed.
• A yellow alarm indicates that the host subsystem has failed.
In
Table 85 on page 354 , the text in the column labeled ”LCD Message” appears in the
display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
Table 85: Chassis Alarm Messages for Host Subsystems
Alarm Type LCD Message CLI Message
Red
Yellow
Host host-number Removed
Host host-number Failure
Host host-number Removed
Host host-number Failure
Solution To troubleshoot the host subsystems:
1.
Check the LEDs on the faceplate of each control board and Routing Engine.
2.
Check the LEDs on the craft interface.
3.
If the red HOST0 FAIL or HOST1 FAIL LED is lit on the craft interface, look at the LCD
4.
Use the show chassis alarms command to check for alarms.
354 Copyright © 2018, Juniper Networks, Inc.
Chapter 36: Troubleshooting Components
Related
Documentation
•
T4000 Host Subsystem Description on page 29
•
T4000 Control Board Description on page 30
•
•
T4000 LCC-CB Control Board LEDs on page 31
•
T4000 Routing Engine Description on page 33
•
T4000 RE-C1800 Routing Engine Description on page 34
•
T4000 RE-C1800 LEDs on page 35
•
Maintaining the T4000 Host Subsystem on page 335
•
Replacing a T4000 LCC-CB on page 275
•
Replacing a T4000 Routing Engine on page 280
Troubleshooting the T4000 Routing Engines
Problem Description:
The following alarms, LEDs, and other conditions indicate a problem with a Routing
Engine:
• The show chassis routing-engine LED on the Routing Engine faceplate is lit steadily red, indicating that the Routing Engine has failed.
• An alarm indicates that a host subsystem has been removed or failed.
Copyright © 2018, Juniper Networks, Inc.
355
T4000 Core Router Hardware Guide
Solution To troubleshoot the Routing Engines:
1.
Use the show chassis routing-engine command.
user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
Temperature 34 degrees C / 93 degrees F
DRAM 2048 Mbytes
CPU utilization:
User 0 percent
Background 0 percent
Kernel 1 percent
Interrupt 0 percent
Idle 99 percent
Start time 2002-01-22 05:21:31 UTC
Uptime 10 days, 16 hours, 4 minutes, 52 seconds
Load averages: 1 minute 5 minute 15 minute
0.00 0.00 0.00
Routing Engine status:
Slot 1:
Current state Empty
Related
Documentation
•
T4000 Host Subsystem Description on page 29
•
T4000 Control Board Description on page 30
•
•
T4000 LCC-CB Control Board LEDs on page 31
•
T4000 Routing Engine Description on page 33
•
T4000 RE-C1800 Routing Engine Description on page 34
•
T4000 RE-C1800 LEDs on page 35
•
Maintaining the T4000 Host Subsystem on page 335
•
Replacing a T4000 LCC-CB on page 275
•
Replacing a T4000 Routing Engine on page 280
Troubleshooting the T4000 Control Boards
Problem Description:
The following alarms and LEDs indicate a problem with a Control Board:
• The yellow FAIL LED on the Control Board faceplate is lit, which indicates that the
Ethernet switch in the Control Board has failed.
• The green OK LED on the Control Board faceplate is not lit.
356 Copyright © 2018, Juniper Networks, Inc.
Chapter 36: Troubleshooting Components
• The red host subsystem FAIL LED on the craft interface is lit, which indicates that the
Control Board has failed or has been removed.
• The green host subsystem OK LED on the craft interface is not lit.
In
Table 86 on page 357 , the text in the LCD Message column appears in the display of
the craft interface. The text in the CLI Message column appears in the output of the show chassis alarms command.
Table 86: T4000 Chassis Alarm Messages and Solutions for the Control Boards
Alarm Type LCD Message CLI Message Alarm Condition Solution
Red CB cb-number
Removed
CB cb-number
Removed
CB cb-number Failure
A Control Board has been removed.
Reinstall the Control Board.
A Control Board has failed.
Replace the Control Board.
Yellow
CB cb-number
Failure
CB cb-number
Ethernet Switch
Failure
CB cb-number
Unsupported
CB cb-number Ethernet
Switch Failure
A Control Board’s
Ethernet switch has failed.
CB cb-number Not
Supported
Replace the Control Board.
An unsupported Control
Board is installed.
Install a supported Control
Board. See
.
NOTE: The CB cb-number Unsupported alarm can occur even when you are integrating a new line-card chassis (LCC) into an existing TX Matrix Plus router. The alarm occurs when the LCC is booting and is unable to check the connectivity between the LCC and the switch-fabric chassis (SFC), before the cable between the Control Board of the LCC and the connector interface panel (CIP) of the SFC is connected. Connecting the LCC CB to the CIP on the SFC clears the alarm.
Solution To troubleshoot the Control Boards:
1.
Check the LEDs on the faceplate of each Control Board.
2.
Check the LEDs on the craft interface.
3.
Use the show chassis alarms command to view the alarms.
4.
Use the show chassis environment cb command to check the status of the Control
Boards. Verify that the Control Boards are Online .
user@host> show chassis environment cb
Copyright © 2018, Juniper Networks, Inc.
357
T4000 Core Router Hardware Guide
CB 0 status:
State Online Master
Temperature 29 degrees C / 84 degrees F
Power:
1.8 V 1809 mV
2.5 V 2496 mV
3.3 V 3295 mV
4.6 V 4687 mV
5.0 V 5042 mV
12.0 V 11985 mV
3.3 V bias 3277 mV
8.0 V bias 7472 mV
GBUS Revision 40
FPGA Revision 7
5.
Based on the messages on the LCD and the CLI, follow the instructions given in
to troubleshoot the Control Board.
Related
Documentation
•
T4000 Host Subsystem Description on page 29
•
T4000 Control Board Description on page 30
•
•
T4000 LCC-CB Control Board LEDs on page 31
•
Maintaining the T4000 Host Subsystem on page 335
•
Replacing a T4000 LCC-CB on page 275
Troubleshooting the T4000 FPCs
Problem Description:
The following LEDs indicate a problem with an FPC:
• The red FAIL LED above the FPC on the craft interface is lit.
• The green FAIL LED above the FPC on the craft interface is lit.
Table 87: Chassis Alarm Messages for the FPCs
Alarm Type LCD Message CLI Message Alarm Condition Solution
Red FPC fpc-slot misconfig FPC fpc-slot misconfig The FPC is not supported, and will not come online.
Remove the unsupported
FPC. See
358 Copyright © 2018, Juniper Networks, Inc.
Chapter 36: Troubleshooting Components
Solution To troubleshoot an FPC:
1.
Look at the display on the craft interface to check the status of the FPC and the PICs that are plugged into it.
2.
Use the show chassis fpc command to check the status of an FPC.
user@host> show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Empty
1 Empty
2 Empty
3 Empty
4 Online 58 11 0 2816 30 27
5 Empty
6 Online 52 13 0 2816 29 27
7 Online 60 12 0 2816 29 27
For more detailed output, add the detail option.
user@host> show chassis fpc detail
Slot 4 information:
State Online
Temperature 58 degrees C / 136 degrees F
Total CPU DRAM 2816 MB
Total SRAM 1554 MB
Total SDRAM 10752 MB
Start time 2011-12-08 21:10:44 PST
Uptime 1 day, 13 hours, 50 minutes, 14 seconds
Slot 6 information:
State Online
Temperature 52 degrees C / 125 degrees F
Total CPU DRAM 2816 MB
Total SRAM 1554 MB
Total SDRAM 10752 MB
Start time 2011-12-08 21:10:50 PST
Uptime 1 day, 13 hours, 50 minutes, 8 seconds
Slot 7 information:
State Online
Temperature 60 degrees C / 140 degrees F
Total CPU DRAM 2816 MB
Total SRAM 1554 MB
Total SDRAM 10752 MB
Start time 2011-12-09 01:33:46 PST
Uptime 1 day, 9 hours, 27 minutes, 12 seconds
For detailed output for a specific FPC, specify a slot number ( 5 ), which is optional: user@host> show chassis fpc detail 5
Slot 5 information:
State Online
Temperature 53 degrees C / 127 degrees F
Total CPU DRAM 2816 MB
Total SRAM 1554 MB
Total SDRAM 10752 MB
Copyright © 2018, Juniper Networks, Inc.
359
T4000 Core Router Hardware Guide
Start time 2011-10-24 09:54:43 UTC
Uptime 14 days, 19 hours, 58 minutes, 13 seconds
3.
Verify that the FPC is properly seated in the midplane. Check that each ejector handle has been turned clockwise and is tight. Use a screwdriver to check that the screws inside the ejector handles are tight.
4.
Use the show chassis fabric fpcs command to check the status of an FPC.
user@host> show chassis fabric fpcs
Fabric management FPC state:
FPC #4
PFE #0
SIB #0
Links ok
SIB #1
Plane enabled
SIB #2
Plane enabled
SIB #3
Plane enabled
SIB #4
Plane enabled
PFE #1
SIB #0
Links ok
SIB #1
Plane enabled
SIB #2
Plane enabled
SIB #3
Plane enabled
SIB #4
Plane enabled
FPC #6
PFE #0
SIB #0
Links ok
SIB #1
Plane enabled
SIB #2
Plane enabled
SIB #3
Plane enabled
SIB #4
Plane enabled
PFE #1
SIB #0
Links ok
SIB #1
Plane enabled
SIB #2
Plane enabled
SIB #3
Plane enabled
SIB #4
Plane enabled
FPC #7
360 Copyright © 2018, Juniper Networks, Inc.
Chapter 36: Troubleshooting Components
PFE #0
SIB #0
Links ok
SIB #1
Plane enabled
SIB #2
Plane enabled
SIB #3
Plane enabled
SIB #4
Plane enabled
PFE #1
SIB #0
Links ok
SIB #1
Plane enabled
SIB #2
Plane enabled
SIB #3
Plane enabled
SIB #4
Plane enabled
5.
Use the show chassis fabric reachability command to check the status of an FPC.
user@host> show chassis fabric reachability
Fabric reachability status: Enabled destinations reachable
Fabric reachability detection:
Unreachable destinations : Present on 0 FPCs
Detected on : 2011-12-10 11:17:43 PST
6.
Use the show chassis environment fpc command to check the status of an FPC.
user@host> show chassis environment fpc
FPC 4 status:
State Online
Fan Intake 34 degrees C / 93 degrees F
Fan Exhaust 58 degrees C / 136 degrees F
PMB 49 degrees C / 120 degrees F
LMB0 65 degrees C / 149 degrees F
LMB1 61 degrees C / 141 degrees F
LMB2 39 degrees C / 102 degrees F
PFE1 LU2 72 degrees C / 161 degrees F
PFE1 LU0 44 degrees C / 111 degrees F
PFE0 LU0 79 degrees C / 174 degrees F
XF1 58 degrees C / 136 degrees F
XF0 63 degrees C / 145 degrees F
XM1 40 degrees C / 104 degrees F
XM0 75 degrees C / 167 degrees F
PFE0 LU1 75 degrees C / 167 degrees F
PFE0 LU2 71 degrees C / 159 degrees F
PFE1 LU1 40 degrees C / 104 degrees F
Power 1
1.0 V 997 mV
1.2 V bias 1195 mV
1.8 V 1782 mV
2.5 V 2494 mV
3.3 V 3296 mV
3.3 V bias 3286 mV
Copyright © 2018, Juniper Networks, Inc.
361
T4000 Core Router Hardware Guide
12.0 V A 10446 mV
12.0 V B 10437 mV
Power 2
0.9 V 901 mV
0.9 V PFE0 919 mV
0.9 V PFE1 904 mV
1.0 V PFE0 991 mV
1.0 V PFE1 970 mV
1.1 V 1096 mV
1.5 V_0 1495 mV
1.5 V_1 1479 mV
Power 3
1.0 V PFE0 1003 mV
1.0 V PFE1 1004 mV
1.0 V PFE0 * 993 mV
1.0 V PFE1 * 996 mV
1.8 V PFE 0 1794 mV
1.8 V PFE 1 1794 mV
2.5 V 2450 mV
12.0 V 11638 mV
Power 4
1.0 V PFE0 LU0 1003 mV
1.0 V PFE1 LU0 1001 mV
1.0 V PFE1 LU2 1001 mV
1.0 V PFE0 LU0 * 995 mV
1.0 V PFE1 LU0 * 995 mV
1.0 V PFE1 LU2 * 995 mV
12.0 V 11614 mV
12.0 V C 11658 mV
Power (Base/PMB/MMB)
LMB0 VDD2V5 2504 mV
LMB0 VDD1V8 1782 mV
LMB0 VDD1V5 1496 mV
LMB0 PFE0 LU0 AVDD1V0 1002 mV
LMB0 PFE0 LU0 VDD1V0 1008 mV
LMB0 VDD12V0 10624 mV
LMB1 VDD2V5 2484 mV
LMB1 VDD1V8 1784 mV
LMB1 VDD1V5 1480 mV
LMB1 PFE0 LU2 AVDD1V0 1000 mV
LMB1 PFE0 LU2 VDD1V0 1006 mV
LMB1 VDD12V0 10704 mV
LMB2 VDD2V5 2492 mV
LMB2 VDD1V8 1794 mV
LMB2 VDD1V5 1492 mV
LMB2 PFE1 LU1 AVDD1V0 998 mV
LMB2 PFE1 LU1 VDD1V0 1006 mV
LMB2 VDD12V0 10576 mV
PMB 1.05v 1049 mV
PMB 1.5v 1500 mV
PMB 2.5v 2500 mV
PMB 3.3v 3300 mV
Bus Revision 80
Related
Documentation
• T4000 Craft Interface LEDs
•
T4000 FPC Description on page 57
•
Maintaining T4000 FPCs on page 337
362 Copyright © 2018, Juniper Networks, Inc.
Chapter 36: Troubleshooting Components
•
Replacing a T4000 FPC on page 295
Troubleshooting the T4000 PICs
Problem Description: A PIC LED lit red indicates a problem with the PIC.
Solution To troubleshoot a PIC:
1.
Check the status of each port on a PIC. Look at the LEDs located on the PIC faceplate.
For information about the meaning of LED states on different PICs, see the T4000
Core Router Interface Module Reference .
2.
Check the status of a PIC, issuing the following CLI command. The PIC slots in the
FPC are numbered from 0 through 3 , top to bottom: user@host> show chassis fpc pic-status
Slot 0 Online FPC Type 4-ES
PIC 0 Online 4x 10GE (LAN/WAN) XFP
PIC 1 Online 4x 10GE (LAN/WAN) XFP
Slot 3 Online FPC Type 5-3D
PIC 0 Online 12x10GE (LAN/WAN) SFPP
PIC 1 Online 12x10GE (LAN/WAN) SFPP
Slot 4 Online FPC Type 5-3D
PIC 0 Online 12x10GE (LAN/WAN) SFPP
PIC 1 Online 12x10GE (LAN/WAN) SFPP
Slot 5 Online FPC Type 5-3D
PIC 0 Online 12x10GE (LAN/WAN) SFPP
PIC 1 Online 12x10GE (LAN/WAN) SFPP
Slot 6 Online FPC Type 5-3D
PIC 0 Online 24x10GE (LAN/WAN) SFPP
PIC 1 Online 24x10GE (LAN/WAN) SFPP
Slot 7 Online FPC Type 5-3D
PIC 0 Online 12x10GE (LAN/WAN) SFPP
PIC 1 Online 1x100GE
Related
Documentation
•
T4000 PIC Description on page 62
•
Replacing a T4000 PIC on page 301
Troubleshooting the T4000 Power System
Problem Description:
The following alarms, LEDs, and other conditions indicate a problem with the power system:
• If all power supplies have failed, the system temperature might have exceeded the threshold, causing the system to shut down.
Copyright © 2018, Juniper Networks, Inc.
363
T4000 Core Router Hardware Guide
364
•
lists alarms for the power system, including the solution.
•
lists abnormal LED states for the power supplies, including the solution.
Solution 1.
Check the display on the craft interface to determine the source of a yellow or red alarm (see
). Junos OS constantly updates the screen with status information for each component.
NOTE: On the display and in the CLI, the power supplies are referred to as PEM0 and PEM1 , from top to bottom.
If the system temperature exceeds the threshold, Junos OS shuts down all power supplies so that no status is displayed.
Junos OS also can shut down one of the power supplies for other reasons.
In that case, the remaining power supply assumes the load, and you can still view the system status through the CLI or display.
2.
Issue the show chassis alarms command to check for power system alarms. See
.
3.
Check the LEDs on each six-input DC power supply faceplate. See
.
4.
Use the show chassis environment pem command.
user@host> show chassis environment pem
PEM 0 status:
State Online
Temperature 34 degrees C / 93 degrees F
DC Input: OK
Voltage(V) Current(A) Power(W) Load(%)
INPUT 0 53.500 7.437 397 52
INPUT 1 53.750 10.812 581 77
INPUT 2 53.125 9.562 507 67
INPUT 3 53.625 11.125 596 79
INPUT 4 53.750 9.875 530 70
INPUT 5 53.250 9.500 505 67
DC Output Voltage(V) Current(A) Power(W) Load(%)
FPC 0 0.000 0.000 0 0
FPC 1 0.000 0.000 0 0
FPC 2 0.000 0.000 0 0
FPC 3 0.000 0.000 0 0
FPC 4 55.375 9.562 529 70
FPC 5 0.062 0.000 0 0
FPC 6 55.062 9.000 495 66
FPC 7 55.437 9.000 498 66
SCG/CB/SIB 55.375 15.375 851 70
FAN 49.000 7.875 385 51
Copyright © 2018, Juniper Networks, Inc.
Chapter 36: Troubleshooting Components
5.
Verify that the customer site circuit breaker for each input has the proper current rating.
NOTE: All inputs on a DC power supply in slot PEM0 must be powered by dedicated power feeds derived from feed A, and all inputs on a DC power supply in slot PEM1 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed
A/B feed redundancy for the system.
6.
Verify that the DC power cables from the power source to the router are not damaged.
If the insulation is cracked or broken, immediately replace the DC power cable .
7.
Connect the power supply to a different power source with a new DC power cable. If the power supply DC OK LED still does not light, the power supply is the source of the problem. Replace the power supply with a spare. If the DC OK LED on the installed spare still does not light—The replaced power supply might also be faulty. To return it for replacement, see
“Contacting Customer Support” on page 375
.
8.
If you cannot determine the cause of the problem or need additional assistance, see
“Contacting Customer Support” on page 375 .
In
Table 88 on page 366 , the text in the column labeled ”LCD Message” appears in the
display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
Copyright © 2018, Juniper Networks, Inc.
365
T4000 Core Router Hardware Guide
Table 88: Power System Chassis Alarms
Alarm Type LCD Message CLI Message
Red PEM pem-number
High Temp
Alarm Condition Solution
PEM pem-number High Temp The power supply is not receiving enough airflow to maintain proper temperature.
Check that the power supply fans are running and that the air filters are clean to be sure they are functioning and providing sufficient airflow through the power supply.
If there is not sufficient airflow, replace the air filters.
Use the show chassis environment pem command to view the temperature.
Yellow
PEM pem-number
Input Fail
PEM pem-number
Not OK
PEM pem-number
Improper
PEM pem-number
Absent
PEM pem-number
Inputs Cfg
PEM pem-number Input Failure
PEM pem-number Not OK
PEM pem-number Improper for
Platform
PEM pem-number Absent
A feed to the power supply has failed.
The power supply experienced a failure.
Replace the power supply.
The power supply is not supported.
A power supply is not installed.
Check the input feed connectivity and voltage levels. Voltage range should be between –40 V and
–72 V.
Install a supported power supply.
Install a supported power supply in the appropriate slot.
PEM pem-number
Configuration
Mismatch-number of inputs
The number of installed cables does not match the number of cables configured in the set chassis pem feeds command.
Ensure that the number of cables connected to the power supply is correct and that the number of cables connected matches the number of feeds configured on the router with the set chassis pem feeds command. Correct one or both of the following:
• add or remove cables connected to the power supply
• reconfigure the number of feeds and the input current by using the set chassis pem feeds and set chassis pem input-current commands
366 Copyright © 2018, Juniper Networks, Inc.
Chapter 36: Troubleshooting Components
Table 89: Troubleshooting PDU LEDs
LED Color State
INPUT
PRESENT
Green Off
DC OK Blue
OVER TEMP Yellow
Off
Blinking steadily
On
Condition Solution
The input is not connected, not receiving voltage or is under –40 V.
•
•
Verify that the customer site circuit breakers are switched on. If the customer site circuit breakers are off, switch them on.
Verify that the input is receiving power within the supported voltage range.
If the customer circuit breakers are switched on but the input is not receiving power, switch off the customer site circuit breakers, and reinstall the DC power source cables.
The power switch on the power supply faceplate is off, the power supply is not functioning normally, or the input voltage is not present or is under –40 V.
Verify that the customer site circuit breakers are switched on, and that the input is receiving power within the supported voltage range.
•
•
If the customer site circuit breakers are off, switch them on.
If the customer circuit breakers are switched on but the input is not receiving power, switch off the customer site circuit breakers, and reinstall the DC power source cables.
The input is okay, but the power supply might not be properly inserted, or there is a fault (such as insufficient airflow or faulty output).
The LED blinks when the power supply is initializing; but if it continues to blink, verify that the power supply is installed properly and that the power supply switch is in the on position.
If the LED continues to blink, replace the power supply.
The power supply is shut down because of excessive internal tempature.
Check the power supply fan and air filters to be sure they are functioning and providing sufficient airflow through the power supply and that the power supply is operating within the specified ambient temperature.
Wait approximately 30 to 60 minutes and turn on the power supply. If the over temperature condition persists, replace the power supply.
Use the show chassis environment pem command to view the temperature.
Related
Documentation
•
T4000 Power System Description on page 75
•
T4000 Six-Input DC Power Supply LEDs on page 77
•
Maintaining the T4000 Power System on page 338
•
Replacing a T4000 Six-Input DC Power Supply on page 307
•
Replacing a T4000 Six-Input DC Power Supply Front Air Filter on page 312
•
Replacing a T4000 Six-Input DC Power Supply Side Air Filter on page 313
Copyright © 2018, Juniper Networks, Inc.
367
T4000 Core Router Hardware Guide
Troubleshooting the T4000 SIBs
Problem Description:
The following alarms and LEDs indicate a problem with a SIB:
• A red alarm indicates that the SIB failed or has been removed or that a spare SIB has failed or has been removed.
• The red FAIL LED on the SIB faceplate is lit.
• The green OK LED on the SIB faceplate is not lit.
In
the text in the column labeled ”LCD Message” appears in the display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
Table 90: T4000 Chassis Alarm Messages for SIBs
Alarm Type LCD Message CLI Message
Red SIB sib-number Failure SIB sib-number Fault
SIB sib-number Removed SIB sib-number Absent
Solution To troubleshoot the T4000 SIBs:
1.
Check the LEDs on the faceplate of each SIB.
2.
Check the LEDs on the craft interface.
3.
Use the CLI to check for alarms.
• Issue the show chassis alarms command to view the alarms.
4.
Use the show chassis sibs command.
user@host> show chassis sibs
Slot State Uptime
0 Spare
1 Online 1 day, 14 hours, 21 minutes, 52 seconds
2 Online 1 day, 14 hours, 21 minutes, 36 seconds
3 Online 1 day, 14 hours, 21 minutes, 19 seconds
4 Online 1 day, 14 hours, 21 minutes, 3 seconds
5.
Use the show chassis fabric sibs command.
user@host> show chassis fabric sibs
368 Copyright © 2018, Juniper Networks, Inc.
Fabric management SIB state:
SIB #0
plane state: S_SPARE
FPC #4
PFE #0 : Links ok
PFE #1 : Links ok
FPC #6
PFE #0 : Links ok
PFE #1 : Links ok
FPC #7
PFE #0 : Links ok
PFE #1 : Links ok
SIB #1
plane state: S_ACTIVE
FPC #4
PFE #0 : Links ok
PFE #1 : Links ok
FPC #6
PFE #0 : Links ok
PFE #1 : Links ok
FPC #7
PFE #0 : Links ok
PFE #1 : Links ok
SIB #2
plane state: S_ACTIVE
FPC #4
PFE #0 : Links ok
PFE #1 : Links ok
FPC #6
PFE #0 : Links ok
PFE #1 : Links ok
FPC #7
PFE #0 : Links ok
PFE #1 : Links ok
SIB #3
plane state: S_ACTIVE
FPC #4
PFE #0 : Links ok
PFE #1 : Links ok
FPC #6
PFE #0 : Links ok
PFE #1 : Links ok
FPC #7
PFE #0 : Links ok
PFE #1 : Links ok
SIB #4
plane state: S_ACTIVE
FPC #4
PFE #0 : Links ok
PFE #1 : Links ok
FPC #6
PFE #0 : Links ok
PFE #1 : Links ok
FPC #7
PFE #0 : Links ok
PFE #1 : Links ok
6.
Use the show chassis environment sib command.
user@host> show chassis environment sib
Copyright © 2018, Juniper Networks, Inc.
Chapter 36: Troubleshooting Components
369
T4000 Core Router Hardware Guide
370
SIB 0 status:
State Online - Standby
Temperature 50 degrees C / 122 degrees F
Power
8.0 V bias 8232 mV
3.3 V bias 3280 mV
0.9 V bias 910 mV
1.1 V bias 1094 mV
1.5 V bias 1486 mV
2.5 V bias 2528 mV
9.0 V 9012 mV
3.3 V 3300 mV
XF0 0.92 V 926 mV
XF0 1.0 V LDO 994 mV
PCIe SW 1.0 V 996 mV
XF0 1.8 V 1792 mV
XF1 0.92 V 922 mV
XF2 0.92 V 922 mV
XF3 1.0 V 1000 mV
1.2 V 1192 mV
XF1 1.0 V LDO 996 mV
XF2 1.0 V LDO 996 mV
XF3 1.0 V LDO 994 mV
XF1 1.8 V 1792 mV
XF2 1.8 V 1796 mV
XF3 1.8 V 1786 mV
1.5 V 1486 mV
SW 3.3 V 3292 mV
SIB 1 status:
State Online
Temperature 49 degrees C / 120 degrees F
Power
8.0 V bias 8280 mV
3.3 V bias 3296 mV
0.9 V bias 910 mV
1.1 V bias 1096 mV
1.5 V bias 1494 mV
2.5 V bias 2524 mV
9.0 V 9000 mV
3.3 V 3296 mV
XF0 1.0 V 1008 mV
XF0 1.0 V LDO 998 mV
PCIe SW 1.0 V 996 mV
XF0 1.8 V 1804 mV
XF1 1.0 V 1004 mV
XF2 1.0 V 1000 mV
XF3 1.0 V 1002 mV
1.2 V 1194 mV
XF1 1.0 V LDO 998 mV
XF2 1.0 V LDO 996 mV
XF3 1.0 V LDO 998 mV
XF1 1.8 V 1808 mV
XF2 1.8 V 1794 mV
XF3 1.8 V 1786 mV
1.5 V 1492 mV
SW 3.3 V 3304 mV
SIB 2 status:
State Online
Temperature 49 degrees C / 120 degrees F
Power
Copyright © 2018, Juniper Networks, Inc.
Chapter 36: Troubleshooting Components
8.0 V bias 8244 mV
3.3 V bias 3296 mV
0.9 V bias 908 mV
1.1 V bias 1098 mV
1.5 V bias 1490 mV
2.5 V bias 2520 mV
9.0 V 9000 mV
3.3 V 3296 mV
XF0 1.0 V 1004 mV
XF0 1.0 V LDO 998 mV
PCIe SW 1.0 V 994 mV
XF0 1.8 V 1790 mV
XF1 1.0 V 1004 mV
XF2 1.0 V 1002 mV
XF3 1.0 V 1004 mV
1.2 V 1198 mV
XF1 1.0 V LDO 1002 mV
XF2 1.0 V LDO 998 mV
XF3 1.0 V LDO 1000 mV
XF1 1.8 V 1794 mV
XF2 1.8 V 1790 mV
XF3 1.8 V 1800 mV
1.5 V 1478 mV
SW 3.3 V 3308 mV
SIB 3 status:
State Online
Temperature 48 degrees C / 118 degrees F
Power
8.0 V bias 8280 mV
3.3 V bias 3300 mV
0.9 V bias 910 mV
1.1 V bias 1098 mV
1.5 V bias 1506 mV
2.5 V bias 2520 mV
9.0 V 8988 mV
3.3 V 3304 mV
XF0 1.0 V 1004 mV
XF0 1.0 V LDO 1000 mV
PCIe SW 1.0 V 996 mV
XF0 1.8 V 1808 mV
XF1 1.0 V 1000 mV
XF2 1.0 V 1002 mV
XF3 1.0 V 1002 mV
1.2 V 1194 mV
XF1 1.0 V LDO 998 mV
XF2 1.0 V LDO 996 mV
XF3 1.0 V LDO 996 mV
XF1 1.8 V 1794 mV
XF2 1.8 V 1794 mV
XF3 1.8 V 1792 mV
1.5 V 1484 mV
SW 3.3 V 3300 mV
SIB 4 status:
State Online
Temperature 50 degrees C / 122 degrees F
Power
8.0 V bias 8268 mV
3.3 V bias 3296 mV
0.9 V bias 910 mV
1.1 V bias 1098 mV
1.5 V bias 1500 mV
Copyright © 2018, Juniper Networks, Inc.
371
T4000 Core Router Hardware Guide
2.5 V bias 2492 mV
9.0 V 9012 mV
3.3 V 3312 mV
XF0 1.0 V 1004 mV
XF0 1.0 V LDO 1002 mV
PCIe SW 1.0 V 996 mV
XF0 1.8 V 1790 mV
XF1 1.0 V 1004 mV
XF2 1.0 V 1006 mV
XF3 1.0 V 1004 mV
1.2 V 1196 mV
XF1 1.0 V LDO 1006 mV
XF2 1.0 V LDO 1002 mV
XF3 1.0 V LDO 1000 mV
XF1 1.8 V 1800 mV
XF2 1.8 V 1800 mV
XF3 1.8 V 1796 mV
1.5 V 1486 mV
SW 3.3 V 3312 mV
Related
Documentation
•
T4000 Switch Interface Board (SIB) Description on page 79
• T4000 Craft Interface LEDs
•
•
Replacing a T4000-SIB on page 319
372 Copyright © 2018, Juniper Networks, Inc.
PART 7
Contacting Customer Support and
Returning the Chassis or Components
•
Contacting Customer Support on page 375
•
Locating Component Serial Numbers on page 377
•
Packing and Returning Components on page 387
Copyright © 2018, Juniper Networks, Inc.
373
T4000 Core Router Hardware Guide
374 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 37
Contacting Customer Support
•
Contacting Customer Support on page 375
Contacting Customer Support
You can contact Juniper Networks Technical Assistance Center (JTAC) 24 hours a day,
7 days a week in one of the following ways:
• On the Web, using the Case Manager link at: https://www.juniper.net/support/
• By telephone:
From the US and Canada: 1-888-314-JTAC
From all other locations: 1-408-745-9500
If contacting JTAC by phone, enter your 12-digit case number followed by the # key if this is an existing case, or press the * key to be routed to the next available support engineer.
When requesting support from JTAC by telephone, be prepared to provide the following information:
• Your existing case number, if you have one
• Details of the failure or problem
• Type of activity being performed on the platform when the problem occurred
• Configuration data using one or more of the show commands
Copyright © 2018, Juniper Networks, Inc.
375
T4000 Core Router Hardware Guide
376 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 38
Locating Component Serial Numbers
•
Displaying T4000 Component Serial Numbers on page 377
•
T4000 Component Serial Number Locations on page 379
Displaying T4000 Component Serial Numbers
Before contacting Juniper Networks, Inc. to request a Return Materials Authorization
(RMA), you must find the serial number on the router or component. To list all of the router components and their serial numbers, enter the following command-line interface
(CLI) command: user@host> show chassis hardware
Hardware inventory:
Item Version Part number Serial number Description
Chassis JN11B7FECAHA T4000
Midplane REV 01 710-027486 RC9244 T-series Backplane
FPM GBUS REV 13 710-002901 BBAF3545 T640 FPM Board
FPM Display REV 03 710-021387 BBAF4338 T4000 FPM Display
CIP REV 06 710-002895 BBAF2353 T-series CIP
PEM 0 REV 02 740-036442 VG00017 Power Entry Module 6x60
SCG 0 REV 18 710-003423 BBAE4908 T640 Sonet Clock Gen.
SCG 1 REV 18 710-003423 BBAB2590 T640 Sonet Clock Gen.
Routing Engine 0 REV 06 740-026941 P737F-002693 RE-DUO-1800
Routing Engine 1 REV 06 740-026941 P737F-002587 RE-DUO-1800
CB 0 REV 09 710-022597 EF6057 LCC Control Board
CB 1 REV 09 710-022597 EF9180 LCC Control Board
FPC 4 REV 05 750-010153 EE9812 FPC Type 5-3D
CPU REV 06 711-030686 EE8534 SNG PMB
PIC 0 REV 07 750-034624 EF6805 12x10GE (LAN/WAN) SFPP
Xcvr 1 REV 01 740-031980 123363A01143 SFP+-10G-SR
PIC 1 REV 02 750-034624 EE3717 12x10GE (LAN/WAN) SFPP
Xcvr 1 REV 01 740-031980 123363A01301 SFP+-10G-SR
Xcvr 4 REV 01 740-031981 UHP016G SFP+-10G-LR
Xcvr 6 REV 01 740-031980 B10M03384 SFP+-10G-SR
Xcvr 7 REV 01 740-031980 AJJ032B SFP+-10G-SR
Xcvr 9 REV 01 740-031980 AJJ03C5 SFP+-10G-SR
Xcvr 10 REV 01 740-031980 AJJ037Y SFP+-10G-SR
Xcvr 11 REV 01 740-031980 AJJ01LW SFP+-10G-SR
LMB 0 REV 04 711-034381 EE8796 Galaxy FPC LU Mezzanine
Board
LMB 1 REV 03 711-035774 EE8818 Type-1 LU Mezzanine Board
LMB 2 REV 04 711-034381 EE8795 Galaxy FPC LU Mezzanine
Board
Copyright © 2018, Juniper Networks, Inc.
377
T4000 Core Router Hardware Guide
FPC 6 REV 26 750-032819 EH3173 FPC Type 5-3D
CPU REV 10 711-030686 EG7759 SNG PMB
PIC 0 REV 08 50-035293 EG2430 1x100GE
Xcvr 0 REV 01 740-032210 C22CTQB CFP-100G-LR4
PIC 1 REV 03 750-035293 EF3655 1x100GE
Xcvr 0 REV 01 740-032210 C22CQXC CFP-100G-LR4
LMB 0 REV 05 711-034381 EG6370 Galaxy FPC LU Mezzanine
Board
LMB 1 REV 04 711-035774 EG6503 Type-1 LU Mezzanine Board
LMB 2 REV 05 711-034381 EG6374 Galaxy FPC LU Mezzanine
Board
FPC 7 REV 24 750-032819 EG9191 FPC Type 5-3D
CPU REV 10 711-030686 EG7776 SNG PMB
PIC 0 REV 07 750-034624 EF6808 12x10GE (LAN/WAN) SFPP
Xcvr 0 REV 01 740-031980 B10M01418 SFP+-10G-SR
Xcvr 1 REV 01 740-031981 UK60DPC SFP+-10G-LR
Xcvr 2 REV 01 740-031980 AJJ01QE SFP+-10G-SR
Xcvr 3 REV 01 740-031980 B10M03379 SFP+-10G-SR
Xcvr 4 REV 01 740-031980 B10M01541 SFP+-10G-SR
Xcvr 5 REV 01 740-031980 B10M03333 SFP+-10G-SR
Xcvr 6 REV 01 740-031980 B10M03344 SFP+-10G-SR
Xcvr 7 REV 01 740-031980 AJJ0399 SFP+-10G-SR
Xcvr 8 REV 01 740-031980 AJJ0339 SFP+-10G-SR
Xcvr 9 REV 01 740-031980 B10M00112 SFP+-10G-SR
Xcvr 10 REV 01 740-031981 UHP0168 SFP+-10G-LR
Xcvr 11 REV 01 740-031980 B10M00452 SFP+-10G-SR
PIC 1 REV 01 750-035293 EE2286 1x100GE
Xcvr 0 REV 01 740-032210 C22CR7E CFP-100G-LR4
LMB 0 REV 03 711-034381 ED8127 Galaxy FPC LU Mezzanine
Board
LMB 1 REV 02 711-035774 EE2480 Type-1 LU Mezzanine Board
LMB 2 REV 03 711-034381 EE3034 Galaxy FPC LU Mezzanine
Board
SPMB 0 REV 05 710-023321 EF9671 LCC Switch CPU
SPMB 1 REV 05 710-023321 EF6092 LCC Switch CPU
SIB 0 REV 07 711-036340 EG2276 SIB-HC-3D
SIB 1 REV 07 711-036340 EG2299 SIB-HC-3D
SIB 2 REV 07 711-036340 EG2302 SIB-HC-3D
SIB 3 REV 02 711-036340 EE6290 SIB-HC-3D
SIB 4 REV 02 711-036340 EF1319 SIB-HC-3D
Fan Tray 0 Front Top Fan Tray --
Rev 2
Fan Tray 1 Front Bottom Fan Tray
Rev 2
Fan Tray 2 Rear Fan Tray -- Rev 3
Related
Documentation
•
Contacting Customer Support on page 375
•
T4000 Component Serial Number Locations on page 379
•
Returning a Hardware Component to Juniper Networks, Inc. on page 387
378 Copyright © 2018, Juniper Networks, Inc.
Chapter 38: Locating Component Serial Numbers
T4000 Component Serial Number Locations
Most components have a small serial number ID label attached to the component body.
For example, many components have a rectangular serial number label as shown in
Figure 142: Serial Number ID Label
•
CIP Serial Number Label on page 379
•
Control Board Serial Number Label on page 380
•
Craft Interface Serial Number Label on page 380
•
FPC Serial Number Label on page 380
•
PIC Serial Number Label on page 382
•
Power Supply Serial Number Label on page 383
•
Routing Engine Serial Number Label on page 383
•
SCG Serial Number Label on page 384
•
SIB Serial Number Label on page 384
CIP Serial Number Label
The serial number label is located at the top of the left side of the CIP (see
Figure 143: CIP Serial Number Label
Copyright © 2018, Juniper Networks, Inc.
379
T4000 Core Router Hardware Guide
Control Board Serial Number Label
The LCC-CB serial number is located on the lower right side of the control board (see
).
Figure 144: LCC-CB Serial Number Label
Craft Interface Serial Number Label
Figure 145: Craft Interface Serial Number ID Label
T Series
FAIL
FPC0
OK
FAIL
ACO/LT
FPC1
OK
MENU
ENTER
FAIL
FPC2
OK
FAIL
FPC3
OK
FAIL
FPC4
OK
FAIL
FPC5
OK
FAIL OK
MASTER
HOST0
FAIL OK
HOST1
MASTER
SIB0
FAIL OK
SIB1
SIB2
SIB3
SIB4
FAIL
FPC6
OK
FAIL
FPC7
OK
AA1234
Serial number ID label
FPC Serial Number Label
The location of the serial number label varies depending on the FPC:
• T1600 Type 4 FPCs: located on the lower right side
• T4000 Type 5 FPCs: located on the upper middle.
shows the serial number location for a T1600 Type 4 FPC.
380 Copyright © 2018, Juniper Networks, Inc.
Chapter 38: Locating Component Serial Numbers
Figure 146: Serial Number Label on a T1600 Type 4 FPC
shows the serial number location for a T4000 Type 5 FPC.
Copyright © 2018, Juniper Networks, Inc.
381
T4000 Core Router Hardware Guide
Figure 147: Type 5 FPC Serial Number ID Label
Serial number ID label
12V
300W
PIC Serial Number Label
The exact location serial number label is different on different PICs, depending on the placement of components on the PIC board. In this example, the serial number label is located on the right side of the PIC (see
), when the PIC is vertically oriented (as it would be installed in the router).
382 Copyright © 2018, Juniper Networks, Inc.
Figure 148: PIC Serial Number Label
Chapter 38: Locating Component Serial Numbers
Power Supply Serial Number Label
For the DC power supply, the serial number label is located on the lower left side of the faceplate. (see
).
Figure 149: DC Power Supply Serial Number Label
Serial number ID label
Routing Engine Serial Number Label
The serial number label is located on the left side (see
).
Copyright © 2018, Juniper Networks, Inc.
383
T4000 Core Router Hardware Guide
Figure 150: Routing Engine
Serial number
ID label
P737F -
SCG Serial Number Label
The serial number is located on the top of the SCG, close to the midplane connector (see
).
NOTE: Although the illustration shows the SCG with DB-9 ports, the serial number location is the same for the SCG with RJ-48 ports.
Figure 151: SCG Serial Number Label
SIB Serial Number Label
The serial number is located on the right side behind the faceplate (see
384 Copyright © 2018, Juniper Networks, Inc.
Chapter 38: Locating Component Serial Numbers
Figure 152: SIB Serial Number ID Label
Serial number ID label
Related
Documentation
•
Displaying T4000 Component Serial Numbers on page 377
Copyright © 2018, Juniper Networks, Inc.
385
T4000 Core Router Hardware Guide
386 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 39
Packing and Returning Components
•
Returning a Hardware Component to Juniper Networks, Inc. on page 387
•
Tools and Parts Required to Remove Components from a T4000 Router on page 388
•
Packing the T4000 Router for Shipment on page 388
•
Packing the T4000 Router Components for Shipment on page 389
Returning a Hardware Component to Juniper Networks, Inc.
In the event of a hardware failure, please contact Juniper Networks, Inc. to obtain a Return
Material Authorization (RMA) number. This number is used to track the returned material at the factory and to return repaired or new components to the customer as needed.
NOTE: Do not return any component to Juniper Networks, Inc. unless you have first obtained an RMA number. Juniper Networks, Inc. reserves the right to refuse shipments that do not have an RMA. Refused shipments are returned to the customer by collect freight.
For more information about return and repair policies, see the customer support Web page at https://www.juniper.net/support/guidelines.html
.
For product problems or technical support issues, contact the Juniper Networks Technical
Assistance Center (JTAC) by using the Case Manager link at https://www.juniper.net/support/ or at 1-888-314-JTAC (within the United States) or
1-408-745-9500 (from outside the United States).
To return a defective hardware component:
1.
Determine the part number and serial number of the defective component.
2.
Obtain an RMA number from the Juniper Networks Technical Assistance Center (JTAC).
You can send e-mail or telephone as described above.
3.
Provide the following information in your e-mail message or during the telephone call:
• Part number and serial number of component
• Your name, organization name, telephone number, and fax number
Copyright © 2018, Juniper Networks, Inc.
387
T4000 Core Router Hardware Guide
• Description of the failure
4.
The support representative validates your request and issues an RMA number for return of the component.
5.
Pack the component for shipment.
Tools and Parts Required to Remove Components from a T4000 Router
To remove components from the router or the router from a rack, you need the following tools and parts:
• 2.5-mm flat-blade (–) screwdriver, for detaching alarm relay terminal block
• 7/16-in. (11 mm) nut driver
• Blank panels to cover empty slots
• Electrostatic bag or antistatic mat, for each component
• Electrostatic discharge (ESD) grounding wrist strap
• Flat-blade (–) screwdriver
• Mechanical lift, if available
• Phillips (+) screwdrivers, numbers 1 and 2
• Rubber safety caps for fiber-optic transceivers and cable
Related
Documentation
•
Tools and Parts Required for Replacing T4000 Hardware Components on page 241
•
Packing the T4000 Router Components for Shipment on page 389
•
Packing the T4000 Router for Shipment on page 388
Packing the T4000 Router for Shipment
To pack the router for shipment:
1.
Retrieve the shipping crate and packing materials in which the router was originally shipped. If you do not have these materials, contact your Juniper Networks representative about approved packaging materials.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
On the console or other management device connected to the master Routing Engine, enter CLI operational mode. To power off the router, see
.
4.
Disconnect power from the router. .
388 Copyright © 2018, Juniper Networks, Inc.
Chapter 39: Packing and Returning Components
5.
Remove the cables that connect to all external devices. For instructions, see
“Removing a T4000 Management Ethernet Cable” on page 253 ,
Auxiliary Cable” on page 251 , and
“Replacing the T4000 Alarm Relay Wires” on page 255 .
6.
Remove all field replaceable units (FRUs) from the router.
7.
Remove the router from the rack:
• If you are using a mechanical lift, place the lift platform under the router, unscrew and remove the mounting screws from the rack, and move the router to the shipping crate.
• If you are not using a mechanical lift:
• If the router weight is fully supported by a shelf or another router, unscrew and remove the mounting screws from the rack. Four people can then lift the router and move it to the shipping crate.
• If the router weight is not fully supported by a shelf or another router, four people should grasp the router while another person unscrews and removes the mounting screws from the rack. The lifters can then move the router to the shipping crate.
8.
Place the router into the shipping crate or onto the pallet. If on a pallet, bolt the router to the pallet.
9.
Cover the router with an ESD bag, and place packing foam on top of and around the router.
10.
Replace the accessory box on top of the packing foam.
11.
Securely tape the box closed or place the crate cover over the router.
12.
Write the Return Materials Authorization (RMA) number on the exterior of the box to ensure proper tracking.
Related
Documentation
•
Contacting Customer Support on page 375
•
Prevention of Electrostatic Discharge Damage on page 423
Packing the T4000 Router Components for Shipment
To pack and ship individual components:
• When you return components, make sure they are adequately protected with packing materials and packed so that the pieces are prevented from moving around inside the carton.
• Use the original shipping materials if they are available.
Copyright © 2018, Juniper Networks, Inc.
389
T4000 Core Router Hardware Guide
• Place individual boards in electrostatic bags.
• Write the Return Materials Authorization (RMA) number on the exterior of the box to ensure proper tracking.
CAUTION: Do not stack any of the router components.
Related
Documentation
•
Contacting Customer Support on page 375
•
Displaying T4000 Component Serial Numbers on page 377
•
T4000 Component Serial Number Locations on page 379
•
Returning a Hardware Component to Juniper Networks, Inc. on page 387
390 Copyright © 2018, Juniper Networks, Inc.
PART 8
Safety and Compliance Information
•
General Safety Guidelines and Warnings on page 393
•
Fire Safety Requirements on page 399
•
Installation Safety Guidelines and Warnings on page 401
•
Radiation and Laser Safety Guidelines and Warnings on page 411
•
Maintenance and Operational Safety Warnings on page 415
•
Electrical Safety Guidelines and Warnings on page 421
•
Agency Approvals and Compliance Statements on page 435
Copyright © 2018, Juniper Networks, Inc.
391
T4000 Core Router Hardware Guide
392 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 40
General Safety Guidelines and Warnings
•
General Safety Guidelines and Warnings on page 393
•
Definitions of Safety Warning Levels on page 394
•
Qualified Personnel Warning on page 396
•
Warning Statement for Norway and Sweden on page 397
General Safety Guidelines and Warnings
The following guidelines help ensure your safety and protect the device from damage.
The list of guidelines might not address all potentially hazardous situations in your working environment, so be alert and exercise good judgment at all times.
• Perform only the procedures explicitly described in the hardware documentation for this device. Make sure that only authorized service personnel perform other system services.
• Keep the area around the device clear and free from dust before, during, and after installation.
• Keep tools away from areas where people could trip over them while walking.
• Do not wear loose clothing or jewelry, such as rings, bracelets, or chains, which could become caught in the device.
• Wear safety glasses if you are working under any conditions that could be hazardous to your eyes.
• Do not perform any actions that create a potential hazard to people or make the equipment unsafe.
• Never attempt to lift an object that is too heavy for one person to handle.
• Never install or manipulate wiring during electrical storms.
• Never install electrical jacks in wet locations unless the jacks are specifically designed for wet environments.
• Operate the device only when it is properly grounded.
• Ensure that the separate protective earthing terminal provided on this device is permanently connected to earth.
• Replace fuses only with fuses of the same type and rating.
Copyright © 2018, Juniper Networks, Inc.
393
T4000 Core Router Hardware Guide
• Do not open or remove chassis covers or sheet-metal parts unless instructions are provided in the hardware documentation for this device. Such an action could cause severe electrical shock.
• Do not push or force any objects through any opening in the chassis frame. Such an action could result in electrical shock or fire.
• Avoid spilling liquid onto the chassis or onto any device component. Such an action could cause electrical shock or damage the device.
• Avoid touching uninsulated electrical wires or terminals that have not been disconnected from their power source. Such an action could cause electrical shock.
• Some parts of the chassis might become hot. The following label provides the warningof the hot surfaces on the chassis:
• Always ensure that all modules, power supplies, and cover panels are fully inserted and that the installation screws are fully tightened.
Related
Documentation
• AC Power Electrical Safety Guidelines
•
General Electrical Safety Guidelines and Warnings on page 421
•
Maintenance and Operational Safety Guidelines and Warnings on page 415
•
Installation Instructions Warning on page 401
•
Grounded Equipment Warning on page 408
Definitions of Safety Warning Levels
The documentation uses the following levels of safety warnings (there are two Warning formats):
NOTE: You might find this information helpful in a particular situation, or you might overlook this important information if it was not highlighted in a Note.
CAUTION: You need to observe the specified guidelines to prevent minor injury or discomfort to you or severe damage to the device.
WARNING: This symbol alerts you to the risk of personal injury from a laser.
WARNING: This symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards
394 Copyright © 2018, Juniper Networks, Inc.
Chapter 40: General Safety Guidelines and Warnings
Copyright © 2018, Juniper Networks, Inc.
involved with electrical circuitry and be familiar with standard practices for preventing accidents.
Waarschuwing Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen.
Varoitus Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa, ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista.
Attention Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant causer des blessures ou des dommages corporels.
Avant de travailler sur un équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents.
Warnung Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer
Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der
Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen
Stromkreisen verbundenen Gefahren und der Standardpraktiken zur
Vermeidung von Unfällen bewußt.
Avvertenza Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti.
Advarsel Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til personskade. Før du utfører arbeid på utstyr, må du vare oppmerksom på de faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med vanlig praksis når det gjelder å unngå ulykker.
Aviso Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos físicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes.
¡Atención!
Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considerar los riesgos que entraña la corriente eléctrica y familiarizarse con los procedimientos estándar de prevención de accidentes.
Varning!
Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning
395
T4000 Core Router Hardware Guide måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador.
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
•
Installation Instructions Warning on page 401
•
Maintenance and Operational Safety Guidelines and Warnings on page 415
•
Grounded Equipment Warning on page 408
•
Laser and LED Safety Guidelines and Warnings on page 412
• Laser and LED Safety Guidelines and Warnings for the ACX5000 Router
• Laser and LED Safety Guidelines and Warnings for the QFX Series
• Laser and LED Safety Guidelines and Warnings for the PTX10008 and PTX10016
•
Warning Statement for Norway and Sweden on page 397
Qualified Personnel Warning
WARNING: Only trained and qualified personnel should install or replace the device.
Waarschuwing Installatie en reparaties mogen uitsluitend door getraind en bevoegd personeel uitgevoerd worden.
Varoitus Ainoastaan koulutettu ja pätevä henkilökunta saa asentaa tai vaihtaa tämän laitteen.
Attention Tout installation ou remplacement de l'appareil doit être réalisé par du personnel qualifié et compétent.
Warnung Gerät nur von geschultem, qualifiziertem Personal installieren oder auswechseln lassen.
Avvertenza Solo personale addestrato e qualificato deve essere autorizzato ad installare o sostituire questo apparecchio.
Advarsel Kun kvalifisert personell med riktig opplæring bør montere eller bytte ut dette utstyret.
Aviso Este equipamento deverá ser instalado ou substituído apenas por pessoal devidamente treinado e qualificado.
¡Atención!
Estos equipos deben ser instalados y reemplazados exclusivamente por personal técnico adecuadamente preparado y capacitado.
396 Copyright © 2018, Juniper Networks, Inc.
Chapter 40: General Safety Guidelines and Warnings
Varning!
Denna utrustning ska endast installeras och bytas ut av utbildad och kvalificerad personal.
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
•
General Electrical Safety Guidelines and Warnings on page 421
• AC Power Electrical Safety Guidelines
• PTX5000 AC Power Electrical Safety Guidelines
• PTX5000 AC Power Electrical Safety Warnings
• DC Power Electrical Safety Guidelines
• PTX1000 DC Power Electrical Safety Guidelines
• PTX3000 DC Power Electrical Safety Guidelines
• PTX5000 DC Power Electrical Safety Guidelines
Warning Statement for Norway and Sweden
WARNING: The equipment must be connected to an earthed mains socket-outlet.
Advarsel Apparatet skal kobles til en jordet stikkontakt.
Varning!
Apparaten skall anslutas till jordat nätuttag.
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
Copyright © 2018, Juniper Networks, Inc.
397
T4000 Core Router Hardware Guide
398 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 41
Fire Safety Requirements
•
Fire Safety Requirements on page 399
Fire Safety Requirements
In the event of a fire emergency, the safety of people is the primary concern. You should establish procedures for protecting people in the event of a fire emergency, provide safety training, and properly provision fire-control equipment and fire extinguishers.
In addition, you should establish procedures to protect your equipment in the event of a fire emergency. Juniper Networks products should be installed in an environment suitable for electronic equipment. We recommend that fire suppression equipment be available in the event of a fire in the vicinity of the equipment and that all local fire, safety, and electrical codes and ordinances be observed when you install and operate your equipment.
Fire Suppression
In the event of an electrical hazard or an electrical fire, you should first turn power off to the equipment at the source. Then use a Type C fire extinguisher, which uses noncorrosive fire retardants, to extinguish the fire.
Fire Suppression Equipment
Type C fire extinguishers, which use noncorrosive fire retardants such as carbon dioxide and Halotron™, are most effective for suppressing electrical fires. Type C fire extinguishers displace oxygen from the point of combustion to eliminate the fire. For extinguishing fire on or around equipment that draws air from the environment for cooling, you should use this type of inert oxygen displacement extinguisher instead of an extinguisher that leaves residues on equipment.
Do not use multipurpose Type ABC chemical fire extinguishers (dry chemical fire extinguishers). The primary ingredient in these fire extinguishers is monoammonium phosphate, which is very sticky and difficult to clean. In addition, in the presence of minute amounts of moisture, monoammonium phosphate can become highly corrosive and corrodes most metals.
Any equipment in a room in which a chemical fire extinguisher has been discharged is subject to premature failure and unreliable operation. The equipment is considered to be irreparably damaged.
Copyright © 2018, Juniper Networks, Inc.
399
T4000 Core Router Hardware Guide
NOTE: To keep warranties effective, do not use a dry chemical fire extinguisher to control a fire at or near a Juniper Networks device. If a dry chemical fire extinguisher is used, the unit is no longer eligible for coverage under a service agreement.
We recommend that you dispose of any irreparably damaged equipment in an environmentally responsible manner.
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
•
General Electrical Safety Guidelines and Warnings on page 421
•
Action to Take After an Electrical Accident on page 422
400 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 42
Installation Safety Guidelines and
Warnings
•
Installation Instructions Warning on page 401
•
Chassis and Component Lifting Guidelines on page 402
•
Restricted Access Warning on page 402
•
•
Rack-Mounting and Cabinet-Mounting Warnings on page 404
•
Grounded Equipment Warning on page 408
Installation Instructions Warning
WARNING: Read the installation instructions before you connect the device to a power source.
Waarschuwing Raadpleeg de installatie-aanwijzingen voordat u het systeem met de voeding verbindt.
Varoitus Lue asennusohjeet ennen järjestelmän yhdistämistä virtalähteeseen.
Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation.
Warnung Lesen Sie die Installationsanweisungen, bevor Sie das System an die Stromquelle anschließen.
Avvertenza Consultare le istruzioni di installazione prima di collegare il sistema all'alimentatore.
Advarsel Les installasjonsinstruksjonene før systemet kobles til strømkilden.
Aviso Leia as instruções de instalação antes de ligar o sistema à sua fonte de energia.
¡Atención!
Ver las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
Copyright © 2018, Juniper Networks, Inc.
401
T4000 Core Router Hardware Guide
Varning!
Läs installationsanvisningarna innan du kopplar systemet till dess strömförsörjningsenhet.
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
•
Laser and LED Safety Guidelines and Warnings on page 412
• Laser and LED Safety Guidelines and Warnings for the ACX5000 Router
•
Grounded Equipment Warning on page 408
Chassis and Component Lifting Guidelines
• Before moving the device to a site, ensure that the site meets the power, environmental, and clearance requirements.
• Before lifting or moving the device, disconnect all external cables and wires.
• As when lifting any heavy object, ensure that most of the weight is borne by your legs rather than your back. Keep your knees bent and your back relatively straight. Do not twist your body as you lift. Balance the load evenly and be sure that your footing is firm.
• Use the following lifting guidelines to lift devices and components:
• Up to 39.7 lb (18 kg): One person.
• 39.7 lb (18 kg) to 70.5 lb (32 kg): Two or more people.
• 70.5 lb (32 kg) to 121.2 lb (55 kg): Three or more people.
• Above 121.2 lbs (55 kg): Material handling systems (such as levers, slings, lifts and so on) must be used. When this is not practical, specially trained persons or systems must be used (riggers or movers).
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
•
Installation Instructions Warning on page 401
Restricted Access Warning
WARNING: This unit is intended for installation in restricted access areas. A restricted access area is an area to which access can be gained only by service personnel through the use of a special tool, lock and key, or other means of security, and which is controlled by the authority responsible for the location.
Waarschuwing Dit toestel is bedoeld voor installatie op plaatsen met beperkte toegang. Een plaats met beperkte toegang is een plaats waar toegang slechts door servicepersoneel verkregen kan worden door middel van een speciaal instrument, een slot en sleutel, of een ander veiligheidsmiddel, en welke
402 Copyright © 2018, Juniper Networks, Inc.
Chapter 42: Installation Safety Guidelines and Warnings
Copyright © 2018, Juniper Networks, Inc.
beheerd wordt door de overheidsinstantie die verantwoordelijk is voor de locatie.
Varoitus Tämä laite on tarkoitettu asennettavaksi paikkaan, johon pääsy on rajoitettua. Paikka, johon pääsy on rajoitettua, tarkoittaa paikkaa, johon vain huoltohenkilöstö pääsee jonkin erikoistyökalun, lukkoon sopivan avaimen tai jonkin muun turvalaitteen avulla ja joka on paikasta vastuussa olevien toimivaltaisten henkilöiden valvoma.
Attention Cet appareil est à installer dans des zones d'accès réservé. Ces dernières sont des zones auxquelles seul le personnel de service peut accéder en utilisant un outil spécial, un mécanisme de verrouillage et une clé, ou tout autre moyen de sécurité. L'accès aux zones de sécurité est sous le contrôle de l'autorité responsable de l'emplacement.
Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem
Zutritt vorgesehen. Ein Bereich mit beschränktem Zutritt ist ein Bereich, zu dem nur Wartungspersonal mit einem Spezialwerkzeugs, Schloß und
Schlüssel oder anderer Sicherheitsvorkehrungen Zugang hat, und der von dem für die Anlage zuständigen Gremium kontrolliert wird.
Avvertenza Questa unità deve essere installata in un'area ad accesso limitato.
Un'area ad accesso limitato è un'area accessibile solo a personale di assistenza tramite un'attrezzo speciale, lucchetto, o altri dispositivi di sicurezza, ed è controllata dall'autorità responsabile della zona.
Advarsel Denne enheten er laget for installasjon i områder med begrenset adgang. Et område med begrenset adgang gir kun adgang til servicepersonale som bruker et spesielt verktøy, lås og nøkkel, eller en annen sikkerhetsanordning, og det kontrolleres av den autoriteten som er ansvarlig for området.
Aviso Esta unidade foi concebida para instalação em áreas de acesso restrito.
Uma área de acesso restrito é uma área à qual apenas tem acesso o pessoal de serviço autorizado, que possua uma ferramenta, chave e fechadura especial, ou qualquer outra forma de segurança. Esta área é controlada pela autoridade responsável pelo local.
¡Atención!
Esta unidad ha sido diseñada para instalarse en áreas de acceso restringido. Área de acceso restringido significa un área a la que solamente tiene acceso el personal de servicio mediante la utilización de una herramienta especial, cerradura con llave, o algún otro medio de seguridad, y que está bajo el control de la autoridad responsable del local.
Varning!
Denna enhet är avsedd för installation i områden med begränsat tillträde. Ett område med begränsat tillträde får endast tillträdas av servicepersonal med ett speciellt verktyg, lås och nyckel, eller annan säkerhetsanordning, och kontrolleras av den auktoritet som ansvarar för området.
403
T4000 Core Router Hardware Guide
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
•
General Electrical Safety Guidelines and Warnings on page 421
•
Installation Instructions Warning on page 401
•
Grounded Equipment Warning on page 408
Ramp Warning
WARNING: When installing the device, do not use a ramp inclined at more than 10 degrees.
Waarschuwing Gebruik een oprijplaat niet onder een hoek van meer dan 10 graden.
Varoitus Älä käytä sellaista kaltevaa pintaa, jonka kaltevuus ylittää 10 astetta.
Attention Ne pas utiliser une rampe dont l'inclinaison est supérieure à 10 degrés.
Warnung Keine Rampen mit einer Neigung von mehr als 10 Grad verwenden.
Avvertenza Non usare una rampa con pendenza superiore a 10 gradi.
Advarsel Bruk aldri en rampe som heller mer enn 10 grader.
Aviso Não utilize uma rampa com uma inclinação superior a 10 graus.
¡Atención!
No usar una rampa inclinada más de 10 grados
Varning!
Använd inte ramp med en lutning på mer än 10 grader.
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
•
Installation Instructions Warning on page 401
•
Grounded Equipment Warning on page 408
Rack-Mounting and Cabinet-Mounting Warnings
Ensure that the rack or cabinet in which the device is installed is evenly and securely supported. Uneven mechanical loading could lead to a hazardous condition.
WARNING: To prevent bodily injury when mounting or servicing the device in a rack, take the following precautions to ensure that the system remains stable. The following directives help maintain your safety:
404 Copyright © 2018, Juniper Networks, Inc.
Copyright © 2018, Juniper Networks, Inc.
Chapter 42: Installation Safety Guidelines and Warnings
• The device must be installed in a rack that is secured to the building structure.
• The device should be mounted at the bottom of the rack if it is the only unit in the rack.
• When mounting the device on a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack.
• If the rack is provided with stabilizing equipment, install the stabilizers before mounting or servicing the device in the rack.
Waarschuwing Om lichamelijk letsel te voorkomen wanneer u dit toestel in een rek monteert of het daar een servicebeurt geeft, moet u speciale voorzorgsmaatregelen nemen om ervoor te zorgen dat het toestel stabiel blijft. De onderstaande richtlijnen worden verstrekt om uw veiligheid te verzekeren:
• De Juniper Networks switch moet in een stellage worden geïnstalleerd die aan een bouwsel is verankerd.
• Dit toestel dient onderaan in het rek gemonteerd te worden als het toestel het enige in het rek is.
• Wanneer u dit toestel in een gedeeltelijk gevuld rek monteert, dient u het rek van onderen naar boven te laden met het zwaarste onderdeel onderaan in het rek.
• Als het rek voorzien is van stabiliseringshulpmiddelen, dient u de stabilisatoren te monteren voordat u het toestel in het rek monteert of het daar een servicebeurt geeft.
Varoitus Kun laite asetetaan telineeseen tai huolletaan sen ollessa telineessä, on noudatettava erityisiä varotoimia järjestelmän vakavuuden säilyttämiseksi, jotta vältytään loukkaantumiselta. Noudata seuraavia turvallisuusohjeita:
• Juniper Networks switch on asennettava telineeseen, joka on kiinnitetty rakennukseen.
• Jos telineessä ei ole muita laitteita, aseta laite telineen alaosaan.
• Jos laite asetetaan osaksi täytettyyn telineeseen, aloita kuormittaminen sen alaosasta kaikkein raskaimmalla esineellä ja siirry sitten sen yläosaan.
• Jos telinettä varten on vakaimet, asenna ne ennen laitteen asettamista telineeseen tai sen huoltamista siinä.
Attention Pour éviter toute blessure corporelle pendant les opérations de montage ou de réparation de cette unité en casier, il convient de prendre des précautions spéciales afin de maintenir la stabilité du système. Les directives ci-dessous sont destinées à assurer la protection du personnel:
405
T4000 Core Router Hardware Guide
406
• Le rack sur lequel est monté le Juniper Networks switch doit être fixé à la structure du bâtiment.
• Si cette unité constitue la seule unité montée en casier, elle doit être placée dans le bas.
• Si cette unité est montée dans un casier partiellement rempli, charger le casier de bas en haut en plaçant l'élément le plus lourd dans le bas.
• Si le casier est équipé de dispositifs stabilisateurs, installer les stabilisateurs avant de monter ou de réparer l'unité en casier.
Warnung Zur Vermeidung von Körperverletzung beim Anbringen oder Warten dieser Einheit in einem Gestell müssen Sie besondere Vorkehrungen treffen, um sicherzustellen, daß das System stabil bleibt. Die folgenden Richtlinien sollen zur Gewährleistung Ihrer Sicherheit dienen:
• Der Juniper Networks switch muß in einem Gestell installiert werden, das in der Gebäudestruktur verankert ist.
• Wenn diese Einheit die einzige im Gestell ist, sollte sie unten im Gestell angebracht werden.
• Bei Anbringung dieser Einheit in einem zum Teil gefüllten Gestell ist das
Gestell von unten nach oben zu laden, wobei das schwerste Bauteil unten im Gestell anzubringen ist.
• Wird das Gestell mit Stabilisierungszubehör geliefert, sind zuerst die
Stabilisatoren zu installieren, bevor Sie die Einheit im Gestell anbringen oder sie warten.
Avvertenza Per evitare infortuni fisici durante il montaggio o la manutenzione di questa unità in un supporto, occorre osservare speciali precauzioni per garantire che il sistema rimanga stabile. Le seguenti direttive vengono fornite per garantire la sicurezza personale:
• Il Juniper Networks switch deve essere installato in un telaio, il quale deve essere fissato alla struttura dell'edificio.
• Questa unità deve venire montata sul fondo del supporto, se si tratta dell'unica unità da montare nel supporto.
• Quando questa unità viene montata in un supporto parzialmente pieno, caricare il supporto dal basso all'alto, con il componente più pesante sistemato sul fondo del supporto.
• Se il supporto è dotato di dispositivi stabilizzanti, installare tali dispositivi prima di montare o di procedere alla manutenzione dell'unità nel supporto.
Advarsel Unngå fysiske skader under montering eller reparasjonsarbeid på denne enheten når den befinner seg i et kabinett. Vær nøye med at systemet er stabilt. Følgende retningslinjer er gitt for å verne om sikkerheten:
Copyright © 2018, Juniper Networks, Inc.
Copyright © 2018, Juniper Networks, Inc.
Chapter 42: Installation Safety Guidelines and Warnings
• Juniper Networks switch må installeres i et stativ som er forankret til bygningsstrukturen.
• Denne enheten bør monteres nederst i kabinettet hvis dette er den eneste enheten i kabinettet.
• Ved montering av denne enheten i et kabinett som er delvis fylt, skal kabinettet lastes fra bunnen og opp med den tyngste komponenten nederst i kabinettet.
• Hvis kabinettet er utstyrt med stabiliseringsutstyr, skal stabilisatorene installeres før montering eller utføring av reparasjonsarbeid på enheten i kabinettet.
Aviso Para se prevenir contra danos corporais ao montar ou reparar esta unidade numa estante, deverá tomar precauções especiais para se certificar de que o sistema possui um suporte estável. As seguintes directrizes ajudá-lo-ão a efectuar o seu trabalho com segurança:
• O Juniper Networks switch deverá ser instalado numa prateleira fixa à estrutura do edificio.
• Esta unidade deverá ser montada na parte inferior da estante, caso seja esta a única unidade a ser montada.
• Ao montar esta unidade numa estante parcialmente ocupada, coloque os itens mais pesados na parte inferior da estante, arrumando-os de baixo para cima.
• Se a estante possuir um dispositivo de estabilização, instale-o antes de montar ou reparar a unidade.
¡Atención!
Para evitar lesiones durante el montaje de este equipo sobre un bastidor, oeriormente durante su mantenimiento, se debe poner mucho cuidado en que el sistema quede bien estable. Para garantizar su seguridad, proceda según las siguientes instrucciones:
• El Juniper Networks switch debe instalarse en un bastidor fijado a la estructura del edificio.
• Colocar el equipo en la parte inferior del bastidor, cuando sea la única unidad en el mismo.
• Cuando este equipo se vaya a instalar en un bastidor parcialmente ocupado, comenzar la instalación desde la parte inferior hacia la superior colocando el equipo más pesado en la parte inferior.
• Si el bastidor dispone de dispositivos estabilizadores, instalar éstos antes de montar o proceder al mantenimiento del equipo instalado en el bastidor.
Varning!
För att undvika kroppsskada när du installerar eller utför underhållsarbete på denna enhet på en ställning måste du vidta särskilda
407
T4000 Core Router Hardware Guide försiktighetsåtgärder för att försäkra dig om att systemet står stadigt. Följande riktlinjer ges för att trygga din säkerhet:
• Juniper Networks switch måste installeras i en ställning som är förankrad i byggnadens struktur.
• Om denna enhet är den enda enheten på ställningen skall den installeras längst ned på ställningen.
• Om denna enhet installeras på en delvis fylld ställning skall ställningen fyllas nedifrån och upp, med de tyngsta enheterna längst ned på ställningen.
• Om ställningen är försedd med stabiliseringsdon skall dessa monteras fast innan enheten installeras eller underhålls på ställningen.
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
•
Installation Instructions Warning on page 401
•
Grounded Equipment Warning on page 408
Grounded Equipment Warning
WARNING: The device is intended to be grounded. During normal use, ensure that you have connected earth ground to the chassis.
Waarschuwing Deze apparatuur hoort geaard te worden Zorg dat de host-computer tijdens normaal gebruik met aarde is verbonden.
Varoitus Tämä laitteisto on tarkoitettu maadoitettavaksi. Varmista, että isäntälaite on yhdistetty maahan normaalikäytön aikana.
Attention Cet équipement doit être relié à la terre. S'assurer que l'appareil hôte est relié à la terre lors de l'utilisation normale.
Warnung Dieses Gerät muß geerdet werden. Stellen Sie sicher, daß das
Host-Gerät während des normalen Betriebs an Erde gelegt ist.
Avvertenza Questa apparecchiatura deve essere collegata a massa. Accertarsi che il dispositivo host sia collegato alla massa di terra durante il normale utilizzo.
Advarsel Dette utstyret skal jordes. Forviss deg om vertsterminalen er jordet ved normalt bruk.
Aviso Este equipamento deverá estar ligado à terra. Certifique-se que o host se encontra ligado à terra durante a sua utilização normal.
¡Atención!
Este equipo debe conectarse a tierra. Asegurarse de que el equipo principal esté conectado a tierra durante el uso normal.
408 Copyright © 2018, Juniper Networks, Inc.
Chapter 42: Installation Safety Guidelines and Warnings
Varning!
Denna utrustning är avsedd att jordas. Se till att värdenheten är jordad vid normal användning.
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
•
Installation Instructions Warning on page 401
• AC Power Electrical Safety Guidelines
• DC Power Electrical Safety Guidelines
Copyright © 2018, Juniper Networks, Inc.
409
T4000 Core Router Hardware Guide
410 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 43
Radiation and Laser Safety Guidelines and
Warnings
•
Radiation from Open Port Apertures Warning on page 411
•
Laser and LED Safety Guidelines and Warnings on page 412
Radiation from Open Port Apertures Warning
WARNING: Because invisible radiation might be emitted from the aperture of the port when no fiber cable is connected, avoid exposure to radiation and do not stare into open apertures.
Waarschuwing Aangezien onzichtbare straling vanuit de opening van de poort kan komen als er geen fiberkabel aangesloten is, dient blootstelling aan straling en het kijken in open openingen vermeden te worden.
Varoitus Koska portin aukosta voi emittoitua näkymätöntä säteilyä, kun kuitukaapelia ei ole kytkettynä, vältä säteilylle altistumista äläkä katso avoimiin aukkoihin.
Attention Des radiations invisibles à l'il nu pouvant traverser l'ouverture du port lorsqu'aucun câble en fibre optique n'y est connecté, il est recommandé de ne pas regarder fixement l'intérieur de ces ouvertures.
Warnung Aus der Port-Öffnung können unsichtbare Strahlen emittieren, wenn kein Glasfaserkabel angeschlossen ist. Vermeiden Sie es, sich den
Strahlungen auszusetzen, und starren Sie nicht in die Öffnungen!
Avvertenza Quando i cavi in fibra non sono inseriti, radiazioni invisibili possono essere emesse attraverso l'apertura della porta. Evitate di esporvi alle radiazioni e non guardate direttamente nelle aperture.
Advarsel Unngå utsettelse for stråling, og stirr ikke inn i åpninger som er åpne, fordi usynlig stråling kan emiteres fra portens åpning når det ikke er tilkoblet en fiberkabel.
Aviso Dada a possibilidade de emissão de radiação invisível através do orifício da via de acesso, quando esta não tiver nenhum cabo de fibra conectado,
Copyright © 2018, Juniper Networks, Inc.
411
T4000 Core Router Hardware Guide deverá evitar a exposição à radiação e não deverá olhar fixamente para orifícios que se encontrarem a descoberto.
¡Atención!
Debido a que la apertura del puerto puede emitir radiación invisible cuando no existe un cable de fibra conectado, evite mirar directamente a las aperturas para no exponerse a la radiación.
Varning!
Osynlig strålning kan avges från en portöppning utan ansluten fiberkabel och du bör därför undvika att bli utsatt för strålning genom att inte stirra in i oskyddade öppningar.
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
•
Laser and LED Safety Guidelines and Warnings on page 412
•
Installation Instructions Warning on page 401
•
Grounded Equipment Warning on page 408
Laser and LED Safety Guidelines and Warnings
Juniper Networks devices are equipped with laser transmitters, which are considered a
Class 1 Laser Product by the U.S. Food and Drug Administration and are evaluated as a
Class 1 Laser Product per EN 60825-1 requirements.
Observe the following guidelines and warnings:
•
General Laser Safety Guidelines on page 412
•
Class 1 Laser Product Warning on page 413
•
Class 1 LED Product Warning on page 413
•
Laser Beam Warning on page 413
General Laser Safety Guidelines
When working around ports that support optical transceivers, observe the following safety guidelines to prevent eye injury:
• Do not look into unterminated ports or at fibers that connect to unknown sources.
• Do not examine unterminated optical ports with optical instruments.
• Avoid direct exposure to the beam.
WARNING: Unterminated optical connectors can emit invisible laser radiation. The lens in the human eye focuses all the laser power on the retina, so focusing the eye directly on a laser source—even a low-power laser—could permanently damage the eye.
412 Copyright © 2018, Juniper Networks, Inc.
Chapter 43: Radiation and Laser Safety Guidelines and Warnings
Class 1 Laser Product Warning
WARNING: Class 1 laser product.
Waarschuwing Klasse-1 laser produkt.
Varoitus Luokan 1 lasertuote.
Attention Produit laser de classe I.
Warnung Laserprodukt der Klasse 1.
Avvertenza Prodotto laser di Classe 1.
Advarsel Laserprodukt av klasse 1.
Aviso Produto laser de classe 1.
¡Atención!
Producto láser Clase I.
Varning!
Laserprodukt av klass 1.
Class 1 LED Product Warning
WARNING: Class 1 LED product.
Waarschuwing Klasse 1 LED-product.
Varoitus Luokan 1 valodiodituote.
Attention Alarme de produit LED Class I.
Warnung Class 1 LED-Produktwarnung.
Avvertenza Avvertenza prodotto LED di Classe 1.
Advarsel LED-produkt i klasse 1.
Aviso Produto de classe 1 com LED.
¡Atención!
Aviso sobre producto LED de Clase 1.
Varning!
Lysdiodprodukt av klass 1.
Laser Beam Warning
WARNING: Do not stare into the laser beam or view it directly with optical instruments.
Copyright © 2018, Juniper Networks, Inc.
413
T4000 Core Router Hardware Guide
Waarschuwing Niet in de straal staren of hem rechtstreeks bekijken met optische instrumenten.
Varoitus Älä katso säteeseen äläkä tarkastele sitä suoraan optisen laitteen avulla.
Attention Ne pas fixer le faisceau des yeux, ni l'observer directement à l'aide d'instruments optiques.
Warnung Nicht direkt in den Strahl blicken und ihn nicht direkt mit optischen
Geräten prüfen.
Avvertenza Non fissare il raggio con gli occhi né usare strumenti ottici per osservarlo direttamente.
Advarsel Stirr eller se ikke direkte p strlen med optiske instrumenter.
Aviso Não olhe fixamente para o raio, nem olhe para ele directamente com instrumentos ópticos.
¡Atención!
No mirar fijamente el haz ni observarlo directamente con instrumentos ópticos.
Varning!
Rikta inte blicken in mot strålen och titta inte direkt på den genom optiska instrument.
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
•
Radiation from Open Port Apertures Warning on page 411
•
Installation Instructions Warning on page 401
•
Grounded Equipment Warning on page 408
414 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 44
Maintenance and Operational Safety
Warnings
•
Maintenance and Operational Safety Guidelines and Warnings on page 415
Maintenance and Operational Safety Guidelines and Warnings
While performing the maintenance activities for devices, observe the following guidelines and warnings:
•
Battery Handling Warning on page 415
•
Jewelry Removal Warning on page 416
•
Lightning Activity Warning on page 417
•
Operating Temperature Warning on page 418
•
Product Disposal Warning on page 419
Battery Handling Warning
WARNING: Replacing a battery incorrectly might result in an explosion.
Replace a battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.
Waarschuwing Er is ontploffingsgevaar als de batterij verkeerd vervangen wordt. Vervang de batterij slechts met hetzelfde of een equivalent type dat door de fabrikant aanbevolen is. Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften weggeworpen te worden.
Varoitus Räjähdyksen vaara, jos akku on vaihdettu väärään akkuun. Käytä vaihtamiseen ainoastaan saman- tai vastaavantyyppistä akkua, joka on valmistajan suosittelema. Hävitä käytetyt akut valmistajan ohjeiden mukaan.
Attention Danger d'explosion si la pile n'est pas remplacée correctement.
Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant. Jeter les piles usagées conformément aux instructions du fabricant.
Copyright © 2018, Juniper Networks, Inc.
415
T4000 Core Router Hardware Guide
Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr.
Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den
Anweisungen des Herstellers.
Advarsel Det kan være fare for eksplosjon hvis batteriet skiftes på feil måte.
Skift kun med samme eller tilsvarende type som er anbefalt av produsenten.
Kasser brukte batterier i henhold til produsentens instruksjoner.
Avvertenza Pericolo di esplosione se la batteria non è installata correttamente. Sostituire solo con una di tipo uguale o equivalente, consigliata dal produttore. Eliminare le batterie usate secondo le istruzioni del produttore.
Aviso Existe perigo de explosão se a bateria for substituída incorrectamente.
Substitua a bateria por uma bateria igual ou de um tipo equivalente recomendado pelo fabricante. Destrua as baterias usadas conforme as instruções do fabricante.
¡Atención!
Existe peligro de explosión si la batería se reemplaza de manera incorrecta. Reemplazar la batería exclusivamente con el mismo tipo o el equivalente recomendado por el fabricante. Desechar las baterías gastadas según las instrucciones del fabricante.
Varning!
Explosionsfara vid felaktigt batteribyte. Ersätt endast batteriet med samma batterityp som rekommenderas av tillverkaren eller motsvarande.
Följ tillverkarens anvisningar vid kassering av använda batterier.
Jewelry Removal Warning
WARNING: Before working on equipment that is connected to power lines, remove jewelry, including rings, necklaces, and watches. Metal objects heat up when connected to power and ground and can cause serious burns or can be welded to the terminals.
Waarschuwing Alvorens aan apparatuur te werken die met elektrische leidingen is verbonden, sieraden (inclusief ringen, kettingen en horloges) verwijderen. Metalen voorwerpen worden warm wanneer ze met stroom en aarde zijn verbonden, en kunnen ernstige brandwonden veroorzaken of het metalen voorwerp aan de aansluitklemmen lassen.
Varoitus Ennen kuin työskentelet voimavirtajohtoihin kytkettyjen laitteiden parissa, ota pois kaikki korut (sormukset, kaulakorut ja kellot mukaan lukien).
Metalliesineet kuumenevat, kun ne ovat yhteydessä sähkövirran ja maan kanssa, ja ne voivat aiheuttaa vakavia palovammoja tai hitsata metalliesineet kiinni liitäntänapoihin.
Attention Avant d'accéder à cet équipement connecté aux lignes électriques,
ôter tout bijou (anneaux, colliers et montres compris). Lorsqu'ils sont branchés
416 Copyright © 2018, Juniper Networks, Inc.
Chapter 44: Maintenance and Operational Safety Warnings
à l'alimentation et reliés à la terre, les objets métalliques chauffent, ce qui peut provoquer des blessures graves ou souder l'objet métallique aux bornes.
Warnung Vor der Arbeit an Geräten, die an das Netz angeschlossen sind, jeglichen Schmuck (einschließlich Ringe, Ketten und Uhren) abnehmen.
Metallgegenstände erhitzen sich, wenn sie an das Netz und die Erde angeschlossen werden, und können schwere Verbrennungen verursachen oder an die Anschlußklemmen angeschweißt werden.
Avvertenza Prima di intervenire su apparecchiature collegate alle linee di alimentazione, togliersi qualsiasi monile (inclusi anelli, collane, braccialetti ed orologi). Gli oggetti metallici si riscaldano quando sono collegati tra punti di alimentazione e massa: possono causare ustioni gravi oppure il metallo può saldarsi ai terminali.
Advarsel Fjern alle smykker (inkludert ringer, halskjeder og klokker) før du skal arbeide på utstyr som er koblet til kraftledninger. Metallgjenstander som er koblet til kraftledninger og jord blir svært varme og kan forårsake alvorlige brannskader eller smelte fast til polene.
Aviso Antes de trabalhar em equipamento que esteja ligado a linhas de corrente, retire todas as jóias que estiver a usar (incluindo anéis, fios e relógios). Os objectos metálicos aquecerão em contacto com a corrente e em contacto com a ligação à terra, podendo causar queimaduras graves ou ficarem soldados aos terminais.
¡Atención!
Antes de operar sobre equipos conectados a líneas de alimentación, quitarse las joyas (incluidos anillos, collares y relojes). Los objetos de metal se calientan cuando se conectan a la alimentación y a tierra, lo que puede ocasionar quemaduras graves o que los objetos metálicos queden soldados a los bornes.
Varning!
Tag av alla smycken (inklusive ringar, halsband och armbandsur) innan du arbetar på utrustning som är kopplad till kraftledningar. Metallobjekt hettas upp när de kopplas ihop med ström och jord och kan förorsaka allvarliga brännskador; metallobjekt kan också sammansvetsas med kontakterna.
Lightning Activity Warning
WARNING: Do not work on the system or connect or disconnect cables during periods of lightning activity.
Waarschuwing Tijdens onweer dat gepaard gaat met bliksem, dient u niet aan het systeem te werken of kabels aan te sluiten of te ontkoppelen.
Varoitus Älä työskentele järjestelmän parissa äläkä yhdistä tai irrota kaapeleita ukkosilmalla.
Copyright © 2018, Juniper Networks, Inc.
417
T4000 Core Router Hardware Guide
Attention Ne pas travailler sur le système ni brancher ou débrancher les câbles pendant un orage.
Warnung Arbeiten Sie nicht am System und schließen Sie keine Kabel an bzw. trennen Sie keine ab, wenn es gewittert.
Avvertenza Non lavorare sul sistema o collegare oppure scollegare i cavi durante un temporale con fulmini.
Advarsel Utfør aldri arbeid på systemet, eller koble kabler til eller fra systemet når det tordner eller lyner.
Aviso Não trabalhe no sistema ou ligue e desligue cabos durante períodos de mau tempo (trovoada).
¡Atención!
No operar el sistema ni conectar o desconectar cables durante el transcurso de descargas eléctricas en la atmósfera.
Varning!
Vid åska skall du aldrig utföra arbete på systemet eller ansluta eller koppla loss kablar.
Operating Temperature Warning
WARNING: To prevent the device from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature. To prevent airflow restriction, allow at least 6 in. (15.2 cm) of clearance around the ventilation openings.
Waarschuwing Om te voorkomen dat welke switch van de Juniper Networks router dan ook oververhit raakt, dient u deze niet te bedienen op een plaats waar de maximale aanbevolen omgevingstemperatuur van 40° C wordt overschreden. Om te voorkomen dat de luchtstroom wordt beperkt, dient er minstens 15,2 cm speling rond de ventilatie-openingen te zijn.
Varoitus Ettei Juniper Networks switch-sarjan reititin ylikuumentuisi, sitä ei saa käyttää tilassa, jonka lämpötila ylittää korkeimman suositellun ympäristölämpötilan 40° C. Ettei ilmanvaihto estyisi, tuuletusaukkojen ympärille on jätettävä ainakin 15,2 cm tilaa.
Attention Pour éviter toute surchauffe des routeurs de la gamme Juniper
Networks switch, ne l'utilisez pas dans une zone où la température ambiante est supérieure à 40° C. Pour permettre un flot d'air constant, dégagez un espace d'au moins 15,2 cm autour des ouvertures de ventilations.
Warnung Um einen Router der switch vor Überhitzung zu schützen, darf dieser nicht in einer Gegend betrieben werden, in der die Umgebungstemperatur das empfohlene Maximum von 40° C überschreitet. Um Lüftungsverschluß zu verhindern, achten Sie darauf, daß mindestens 15,2 cm lichter Raum um die Lüftungsöffnungen herum frei bleibt.
418 Copyright © 2018, Juniper Networks, Inc.
Chapter 44: Maintenance and Operational Safety Warnings
Avvertenza Per evitare il surriscaldamento dei switch, non adoperateli in un locale che ecceda la temperatura ambientale massima di 40° C. Per evitare che la circolazione dell'aria sia impedita, lasciate uno spazio di almeno 15.2 cm di fronte alle aperture delle ventole.
Advarsel Unngå overoppheting av eventuelle rutere i Juniper Networks switch
Disse skal ikke brukes på steder der den anbefalte maksimale omgivelsestemperaturen overstiger 40° C (104° F). Sørg for at klaringen rundt lufteåpningene er minst 15,2 cm (6 tommer) for å forhindre nedsatt luftsirkulasjon.
Aviso Para evitar o sobreaquecimento do encaminhador Juniper Networks switch, não utilize este equipamento numa área que exceda a temperatura máxima recomendada de 40° C. Para evitar a restrição à circulação de ar, deixe pelo menos um espaço de 15,2 cm à volta das aberturas de ventilação.
¡Atención!
Para impedir que un encaminador de la serie Juniper Networks switch se recaliente, no lo haga funcionar en un área en la que se supere la temperatura ambiente máxima recomendada de 40° C. Para impedir la restricción de la entrada de aire, deje un espacio mínimo de 15,2 cm alrededor de las aperturas para ventilación.
Varning!
Förhindra att en Juniper Networks switch överhettas genom att inte använda den i ett område där den maximalt rekommenderade omgivningstemperaturen på 40° C överskrids. Förhindra att luftcirkulationen inskränks genom att se till att det finns fritt utrymme på minst 15,2 cm omkring ventilationsöppningarna.
Product Disposal Warning
WARNING: Disposal of this device must be handled according to all national laws and regulations.
Waarschuwing Dit produkt dient volgens alle landelijke wetten en voorschriften te worden afgedankt.
Varoitus Tämän tuotteen lopullisesta hävittämisestä tulee huolehtia kaikkia valtakunnallisia lakeja ja säännöksiä noudattaen.
Attention La mise au rebut définitive de ce produit doit être effectuée conformément à toutes les lois et réglementations en vigueur.
Warnung Dieses Produkt muß den geltenden Gesetzen und Vorschriften entsprechend entsorgt werden.
Avvertenza L'eliminazione finale di questo prodotto deve essere eseguita osservando le normative italiane vigenti in materia
Copyright © 2018, Juniper Networks, Inc.
419
T4000 Core Router Hardware Guide
Advarsel Endelig disponering av dette produktet må skje i henhold til nasjonale lover og forskrifter.
Aviso A descartagem final deste produto deverá ser efectuada de acordo com os regulamentos e a legislação nacional.
¡Atención!
El desecho final de este producto debe realizarse según todas las leyes y regulaciones nacionales
Varning!
Slutlig kassering av denna produkt bör skötas i enlighet med landets alla lagar och föreskrifter.
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
•
General Electrical Safety Guidelines and Warnings on page 421
• AC Power Electrical Safety Guidelines
• DC Power Electrical Safety Guidelines
•
Laser and LED Safety Guidelines and Warnings on page 412
•
Installation Instructions Warning on page 401
•
Grounded Equipment Warning on page 408
420 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 45
Electrical Safety Guidelines and Warnings
•
General Electrical Safety Guidelines and Warnings on page 421
•
Action to Take After an Electrical Accident on page 422
•
Prevention of Electrostatic Discharge Damage on page 423
•
T4000 DC Power Electrical Safety Guidelines on page 424
•
DC Power Copper Conductors Warning on page 425
•
DC Power Disconnection Warning on page 426
•
DC Power Grounding Requirements and Warning on page 427
•
DC Power Wiring Sequence Warning on page 428
•
DC Power Wiring Terminations Warning on page 430
•
Midplane Energy Hazard Warning on page 431
•
Multiple Power Supplies Disconnection Warning on page 432
•
General Electrical Safety Guidelines and Warnings
WARNING: Certain ports on the device are designed for use as intrabuilding
(within-the-building) interfaces only (Type 2 or Type 4 ports as described in
GR-1089-CORE) and require isolation from the exposed outside plant (OSP) cabling. To comply with NEBS requirements and protect against lightning surges and commercial power disturbances, the intrabuilding ports must not be metallically connected to interfaces that connect to the OSP or its wiring.
The intrabuilding ports on the device are suitable for connection to intrabuilding or unexposed wiring or cabling only. The addition of primary protectors is not sufficient protection for connecting these interfaces metallically to OSP wiring.
CAUTION: Before removing or installing components of a device, connect an electrostatic discharge (ESD) grounding strap to an ESD point and wrap and fasten the other end of the strap around your bare wrist. Failure to use an ESD grounding strap could result in damage to the device.
Copyright © 2018, Juniper Networks, Inc.
421
T4000 Core Router Hardware Guide
• Install the device in compliance with the following local, national, and international electrical codes:
• United States—National Fire Protection Association (NFPA 70), United States
National Electrical Code.
• Other countries—International Electromechanical Commission (IEC) 60364, Part 1 through Part 7.
• Evaluated to the TN power system.
• Canada—Canadian Electrical Code, Part 1, CSA C22.1.
• Locate the emergency power-off switch for the room in which you are working so that if an electrical accident occurs, you can quickly turn off the power.
• Make sure that grounding surfaces are cleaned and brought to a bright finish before grounding connections are made.
• Do not work alone if potentially hazardous conditions exist anywhere in your workspace.
• Never assume that power is disconnected from a circuit. Always check the circuit before starting to work.
• Carefully look for possible hazards in your work area, such as moist floors, ungrounded power extension cords, and missing safety grounds.
• Operate the device within marked electrical ratings and product usage instructions.
• To ensure that the device and peripheral equipment function safely and correctly, use the cables and connectors specified for the attached peripheral equipment, and make certain they are in good condition.
You can remove and replace many device components without powering off or disconnecting power to the device, as detailed elsewhere in the hardware documentation for this device. Never install equipment that appears to be damaged.
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
• AC Power Electrical Safety Guidelines
• DC Power Electrical Safety Guidelines
Action to Take After an Electrical Accident
If an electrical accident results in an injury, take the following actions in this order:
1.
Use caution. Be aware of potentially hazardous conditions that could cause further injury.
2.
Disconnect power from the device.
3.
If possible, send another person to get medical aid. Otherwise, assess the condition of the victim, then call for help.
422 Copyright © 2018, Juniper Networks, Inc.
Chapter 45: Electrical Safety Guidelines and Warnings
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
•
General Electrical Safety Guidelines and Warnings on page 421
• AC Power Electrical Safety Guidelines
• DC Power Electrical Safety Guidelines
Prevention of Electrostatic Discharge Damage
Device components that are shipped in antistatic bags are sensitive to damage from static electricity. Some components can be impaired by voltages as low as 30 V. You can easily generate potentially damaging static voltages whenever you handle plastic or foam packing material or if you move components across plastic or carpets. Observe the following guidelines to minimize the potential for electrostatic discharge (ESD) damage, which can cause intermittent or complete component failures:
• Always use an ESD wrist strap when you are handling components that are subject to
ESD damage, and make sure that it is in direct contact with your skin.
If a grounding strap is not available, hold the component in its antistatic bag (see
) in one hand and touch the exposed, bare metal of the device with the other hand immediately before inserting the component into the device.
WARNING: For safety, periodically check the resistance value of the ESD grounding strap. The measurement must be in the range 1 through
10 Mohms.
• When handling any component that is subject to ESD damage and that is removed from the device, make sure the equipment end of your ESD wrist strap is attached to the ESD point on the chassis.
If no grounding strap is available, touch the exposed, bare metal of the device to ground yourself before handling the component.
• Avoid contact between the component that is subject to ESD damage and your clothing.
ESD voltages emitted from clothing can damage components.
• When removing or installing a component that is subject to ESD damage, always place it component-side up on an antistatic surface, in an antistatic card rack, or in an antistatic bag (see
). If you are returning a component, place it in an antistatic bag before packing it.
Copyright © 2018, Juniper Networks, Inc.
423
T4000 Core Router Hardware Guide
Figure 153: Placing a Component into an Antistatic Bag
CAUTION
ELECTROSTATIC
SENSITIVE
DEVICES
DO NOT OPEN OR HANDLE
EXCEPT AT A
STATIC-FREE WORKSTATION
6xGE
SFP
0
1
2
3
4
5
CAUTION: ANSI/TIA/EIA-568 cables such as Category 5e and Category 6 can get electrostatically charged. To dissipate this charge, always ground the cables to a suitable and safe earth ground before connecting them to the system.
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
T4000 DC Power Electrical Safety Guidelines
The following electrical safety guidelines apply to a DC-powered router:
• Incorporate an easily accessible disconnect device into the facility wiring. In the United
States and Canada, the –48 VDC facility should be equipped with a circuit breaker rated a minimum of 125% of the power provisioned for the input in accordance with the National Electrical Code in the US and the Canadian Electrical Code in Canada.
WARNING: Failure to provide the required circuit breaker or current-limiting fuse for each DC power cable can cause injury or damage to equipment.
Each 48 VDC facility DC source input power cable must be equipped with a current-limiting fuse or circuit breaker external to the Juniper Networks equipment rated at 100 A (–48 VDC) maximum for the six-input DC power supply, or as required by local code. The voltage rating of the facility DC source circuit breaker must be 80
V minimum. We recommend an 80 A circuit breaker or current-limiting fuse rated for each 60 A DC power cable. We recommend a 100 A circuit breaker or current-limiting fuse rated for each 80 A DC power cable
• The marked input voltage of –48 VDC for a DC-powered router is the nominal voltage associated with the battery circuit, and any higher voltages are only to be associated with float voltages for the charging function.
424 Copyright © 2018, Juniper Networks, Inc.
Chapter 45: Electrical Safety Guidelines and Warnings
• A DC-powered router that is equipped with a DC terminal block is intended only for installation in a restricted access location. In the United States, a restricted access area is one in accordance with Articles 110-16, 110-17, and 110-18 of the National Electrical
Code ANSI/NFPA 70.
NOTE: Primary overcurrent protection is provided by the building circuit breaker. This breaker should protect against excess currents, short circuits, and earth faults in accordance with NEC ANSI/NFPA70.
• A DC-powered router is equipped with a DC terminal block that is rated for the power requirements of a maximally configured router. To supply sufficient power, terminate the DC input wiring on a facility DC source capable of supplying at least 60 A @ –48 VDC per input for the six-input DC power supply.
Run two wires from the circuit breaker box to a source of 48 VDC. Use appropriate gauge wire to handle up to 80 A for 60 A DC power cables or 100 A for 80 A DC power cables. .
NOTE: Only 60 A feeds are currently supported.
• Be sure to connect the ground wire or conduit to a solid office (earth) ground. A closed loop ring is recommended for terminating the ground conductor at the ground stud.
• Ensure that the polarity of the DC input wiring is correct. Under certain conditions, connections with reversed polarity might trip the primary circuit breaker or damage the equipment.
• For personal safety, connect the green and yellow wire to safety (earth) ground at both the router and the supply side of the DC wiring.
• Because the router is a positive ground system, you must connect the positive lead to the terminal labeled RTN , the negative lead to the terminal labeled –48V , and the earth ground to the chassis grounding points.
Related
Documentation
•
Site Electrical Wiring Guidelines on page 93
•
General Electrical Safety Guidelines and Warnings on page 421
•
T4000 DC Power System Electrical Specifications on page 101
DC Power Copper Conductors Warning
WARNING: Use copper conductors only.
Waarschuwing Gebruik alleen koperen geleiders.
Varoitus Käytä vain kuparijohtimia.
Copyright © 2018, Juniper Networks, Inc.
425
T4000 Core Router Hardware Guide
Attention Utilisez uniquement des conducteurs en cuivre.
Warnung Verwenden Sie ausschließlich Kupferleiter.
Avvertenza Usate unicamente dei conduttori di rame.
Advarsel Bruk bare kobberledninger.
Aviso Utilize apenas fios condutores de cobre.
¡Atención!
Emplee sólo conductores de cobre.
Varning!
Använd endast ledare av koppar.
DC Power Disconnection Warning
WARNING: Before performing any of the DC power procedures, ensure that power is removed from the DC circuit. To ensure that all power is off, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the OFF position, and tape the device handle of the circuit breaker in the OFF position.
Waarschuwing Voordat u een van de onderstaande procedures uitvoert, dient u te controleren of de stroom naar het gelijkstroom circuit uitgeschakeld is. Om u ervan te verzekeren dat alle stroom UIT is geschakeld, kiest u op het schakelbord de stroomverbreker die het gelijkstroom circuit bedient, draait de stroomverbreker naar de UIT positie en plakt de schakelaarhendel van de stroomverbreker met plakband in de UIT positie vast.
Varoitus Varmista, että tasavirtapiirissä ei ole virtaa ennen seuraavien toimenpiteiden suorittamista. Varmistaaksesi, että virta on KATKAISTU täysin, paikanna tasavirrasta huolehtivassa kojetaulussa sijaitseva suojakytkin, käännä suojakytkin KATKAISTU-asentoon ja teippaa suojakytkimen varsi niin, että se pysyy KATKAISTU-asennossa.
Attention Avant de pratiquer l'une quelconque des procédures ci-dessous, vérifier que le circuit en courant continu n'est plus sous tension. Pour en être sûr, localiser le disjoncteur situé sur le panneau de service du circuit en courant continu, placer le disjoncteur en position fermée (OFF) et, à l'aide d'un ruban adhésif, bloquer la poignée du disjoncteur en position OFF.
Warnung Vor Ausführung der folgenden Vorgänge ist sicherzustellen, daß die Gleichstromschaltung keinen Strom erhält. Um sicherzustellen, daß sämtlicher Strom abgestellt ist, machen Sie auf der Schalttafel den
Unterbrecher für die Gleichstromschaltung ausfindig, stellen Sie den
Unterbrecher auf AUS, und kleben Sie den Schaltergriff des Unterbrechers mit Klebeband in der AUS-Stellung fest.
426 Copyright © 2018, Juniper Networks, Inc.
Chapter 45: Electrical Safety Guidelines and Warnings
Avvertenza Prima di svolgere una qualsiasi delle procedure seguenti, verificare che il circuito CC non sia alimentato. Per verificare che tutta l'alimentazione sia scollegata (OFF), individuare l'interruttore automatico sul quadro strumenti che alimenta il circuito CC, mettere l'interruttore in posizione OFF e fissarlo con nastro adesivo in tale posizione.
Advarsel Før noen av disse prosedyrene utføres, kontroller at strømmen er frakoblet likestrømkretsen. Sørg for at all strøm er slått AV. Dette gjøres ved
å lokalisere strømbryteren på brytertavlen som betjener likestrømkretsen, slå strømbryteren AV og teipe bryterhåndtaket på strømbryteren i AV-stilling.
Aviso Antes de executar um dos seguintes procedimentos, certifique-se que desligou a fonte de alimentação de energia do circuito de corrente contínua.
Para se assegurar que toda a corrente foi DESLIGADA, localize o disjuntor no painel que serve o circuito de corrente contínua e coloque-o na posição OFF
(Desligado), segurando nessa posição a manivela do interruptor do disjuntor com fita isoladora.
¡Atención!
Antes de proceder con los siguientes pasos, comprobar que la alimentación del circuito de corriente continua (CC) esté cortada (OFF). Para asegurarse de que toda la alimentación esté cortada (OFF), localizar el interruptor automático en el panel que alimenta al circuito de corriente continua, cambiar el interruptor automático a la posición de Apagado (OFF), y sujetar con cinta la palanca del interruptor automático en posición de
Apagado (OFF).
Varning!
Innan du utför någon av följande procedurer måste du kontrollera att strömförsörjningen till likströmskretsen är bruten. Kontrollera att all strömförsörjning är BRUTEN genom att slå AV det överspänningsskydd som skyddar likströmskretsen och tejpa fast överspänningsskyddets omkopplare i FRÅN-läget.
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
•
General Electrical Safety Guidelines and Warnings on page 421
• DC Power Electrical Safety Guidelines
•
DC Power Grounding Requirements and Warning on page 427
•
DC Power Wiring Sequence Warning on page 428
•
DC Power Wiring Terminations Warning on page 430
DC Power Grounding Requirements and Warning
An insulated grounding conductor that is identical in size to the grounded and ungrounded branch circuit supply conductors but is identifiable by green and yellow stripes is installed as part of the branch circuit that supplies the device. The grounding conductor is a separately derived system at the supply transformer or motor generator set.
Copyright © 2018, Juniper Networks, Inc.
427
T4000 Core Router Hardware Guide
WARNING: When you install the device, the ground connection must always be made first and disconnected last.
Waarschuwing Bij de installatie van het toestel moet de aardverbinding altijd het eerste worden gemaakt en het laatste worden losgemaakt.
Varoitus Laitetta asennettaessa on maahan yhdistäminen aina tehtävä ensiksi ja maadoituksen irti kytkeminen viimeiseksi.
Attention Lors de l'installation de l'appareil, la mise à la terre doit toujours
être connectée en premier et déconnectée en dernier.
Warnung Der Erdanschluß muß bei der Installation der Einheit immer zuerst hergestellt und zuletzt abgetrennt werden.
Avvertenza In fase di installazione dell'unità, eseguire sempre per primo il collegamento a massa e disconnetterlo per ultimo.
Advarsel Når enheten installeres, må jordledningen alltid tilkobles først og frakobles sist.
Aviso Ao instalar a unidade, a ligação à terra deverá ser sempre a primeira a ser ligada, e a última a ser desligada.
¡Atención!
Al instalar el equipo, conectar la tierra la primera y desconectarla la última.
Varning!
Vid installation av enheten måste jordledningen alltid anslutas först och kopplas bort sist.
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
•
General Electrical Safety Guidelines and Warnings on page 421
• DC Power Electrical Safety Guidelines
•
DC Power Copper Conductors Warning on page 425
•
DC Power Disconnection Warning on page 426
•
DC Power Wiring Sequence Warning on page 428
•
DC Power Wiring Terminations Warning on page 430
DC Power Wiring Sequence Warning
WARNING: Wire the DC power supply using the appropriate lugs. When connecting power, the proper wiring sequence is ground to ground, +RTN to
+RTN, then –48 V to –48 V. When disconnecting power, the proper wiring
428 Copyright © 2018, Juniper Networks, Inc.
Chapter 45: Electrical Safety Guidelines and Warnings
Copyright © 2018, Juniper Networks, Inc.
sequence is –48 V to –48 V, +RTN to +RTN, then ground to ground. Note that the ground wire must always be connected first and disconnected last.
Waarschuwing De juiste bedradingsvolgorde verbonden is aarde naar aarde,
+RTN naar +RTN, en –48 V naar – 48 V. De juiste bedradingsvolgorde losgemaakt is en –48 naar –48 V, +RTN naar +RTN, aarde naar aarde.
Varoitus Oikea yhdistettava kytkentajarjestys on maajohto maajohtoon,
+RTN varten +RTN, –48 V varten – 48 V. Oikea irrotettava kytkentajarjestys on –48 V varten – 48 V, +RTN varten +RTN, maajohto maajohtoon.
Attention Câblez l'approvisionnement d'alimentation CC En utilisant les crochets appropriés à l'extrémité de câblage. En reliant la puissance, l'ordre approprié de câblage est rectifié pour rectifier, +RTN à +RTN, puis –48 V à
–48 V. En débranchant la puissance, l'ordre approprié de câblage est –48 V
à –48 V, +RTN à +RTN, a alors rectifié pour rectifier. Notez que le fil de masse devrait toujours être relié d'abord et débranché pour la dernière fois. Notez que le fil de masse devrait toujours être relié d'abord et débranché pour la dernière fois.
Warnung Die Stromzufuhr ist nur mit geeigneten Ringösen an das DC Netzteil anzuschliessen. Die richtige Anschlusssequenz ist: Erdanschluss zu
Erdanschluss, +RTN zu +RTN und dann -48V zu -48V. Die richtige Sequenz zum Abtrennen der Stromversorgung ist -48V zu -48V, +RTN zu +RTN und dann Erdanschluss zu Erdanschluss. Es ist zu beachten dass der Erdanschluss immer zuerst angeschlossen und als letztes abgetrennt wird.
Avvertenza Mostra la morsettiera dell alimentatore CC. Cablare l'alimentatore
CC usando i connettori adatti all'estremità del cablaggio, come illustrato. La corretta sequenza di cablaggio è da massa a massa, da positivo a positivo
(da linea ad L) e da negativo a negativo (da neutro a N). Tenere presente che il filo di massa deve sempre venire collegato per primo e scollegato per ultimo.
Advarsel Riktig tilkoples tilkoplingssekvens er jord til jord, +RTN til +RTN,
–48 V til – 48 V. Riktig frakoples tilkoplingssekvens er –48 V til – 48 V, +RTN til +RTN, jord til jord.
Aviso Ate con alambre la fuente de potencia cc Usando los terminales apropiados en el extremo del cableado. Al conectar potencia, la secuencia apropiada del cableado se muele para moler, +RTN a +RTN, entonces –48 V a –48 V. Al desconectar potencia, la secuencia apropiada del cableado es
–48 V a –48 V, +RTN a +RTN, entonces molió para moler. Observe que el alambre de tierra se debe conectar siempre primero y desconectar por último.
Observe que el alambre de tierra se debe conectar siempre primero y desconectar por último.
¡Atención!
Wire a fonte de alimentação de DC Usando os talões apropriados na extremidade da fiação. Ao conectar a potência, a seqüência apropriada da fiação é moída para moer, +RTN a +RTN, então –48 V a –48 V. Ao desconectar a potência, a seqüência apropriada da fiação é –48 V a –48 V,
429
T4000 Core Router Hardware Guide
+RTN a +RTN, moeu então para moer. Anote que o fio à terra deve sempre ser conectado primeiramente e desconectado por último. Anote que o fio à terra deve sempre ser conectado primeiramente e desconectado por último.
Varning!
Korrekt kopplingssekvens ar jord till jord, +RTN till +RTN, –48 V till
–48 V. Korrekt kopplas kopplingssekvens ar –48 V till –48 V, +RTN till +RTN, jord till jord.
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
•
General Electrical Safety Guidelines and Warnings on page 421
• DC Power Electrical Safety Guidelines
•
DC Power Disconnection Warning on page 426
•
DC Power Grounding Requirements and Warning on page 427
•
DC Power Wiring Terminations Warning on page 430
DC Power Wiring Terminations Warning
WARNING: When stranded wiring is required, use approved wiring terminations, such as closed-loop or spade-type with upturned lugs. These terminations must be the appropriate size for the wires and must clamp both the insulation and conductor.
Waarschuwing Wanneer geslagen bedrading vereist is, dient u bedrading te gebruiken die voorzien is van goedgekeurde aansluitingspunten, zoals het gesloten-lus type of het grijperschop type waarbij de aansluitpunten omhoog wijzen. Deze aansluitpunten dienen de juiste maat voor de draden te hebben en dienen zowel de isolatie als de geleider vast te klemmen.
Varoitus Jos säikeellinen johdin on tarpeen, käytä hyväksyttyä johdinliitäntää, esimerkiksi suljettua silmukkaa tai kourumaista liitäntää, jossa on ylöspäin käännetyt kiinnityskorvat. Tällaisten liitäntöjen tulee olla kooltaan johtimiin sopivia ja niiden tulee puristaa yhteen sekä eristeen että johdinosan.
Attention Quand des fils torsadés sont nécessaires, utiliser des douilles terminales homologuées telles que celles à circuit fermé ou du type à plage ouverte avec cosses rebroussées. Ces douilles terminales doivent être de la taille qui convient aux fils et doivent être refermées sur la gaine isolante et sur le conducteur.
Warnung Wenn Litzenverdrahtung erforderlich ist, sind zugelassene
Verdrahtungsabschlüsse, z.B. für einen geschlossenen Regelkreis oder gabelförmig, mit nach oben gerichteten Kabelschuhen zu verwenden. Diese
Abschlüsse sollten die angemessene Größe für die Drähte haben und sowohl die Isolierung als auch den Leiter festklemmen.
430 Copyright © 2018, Juniper Networks, Inc.
Chapter 45: Electrical Safety Guidelines and Warnings
Avvertenza Quando occorre usare trecce, usare connettori omologati, come quelli a occhiello o a forcella con linguette rivolte verso l'alto. I connettori devono avere la misura adatta per il cablaggio e devono serrare sia l'isolante che il conduttore.
Advarsel Hvis det er nødvendig med flertrådede ledninger, brukes godkjente ledningsavslutninger, som for eksempel lukket sløyfe eller spadetype med oppoverbøyde kabelsko. Disse avslutningene skal ha riktig størrelse i forhold til ledningene, og skal klemme sammen både isolasjonen og lederen.
Aviso Quando forem requeridas montagens de instalação eléctrica de cabo torcido, use terminações de cabo aprovadas, tais como, terminações de cabo em circuito fechado e planas com terminais de orelha voltados para cima.
Estas terminações de cabo deverão ser do tamanho apropriado para os respectivos cabos, e deverão prender simultaneamente o isolamento e o fio condutor.
¡Atención!
Cuando se necesite hilo trenzado, utilizar terminales para cables homologados, tales como las de tipo "bucle cerrado" o "espada", con las lengüetas de conexión vueltas hacia arriba. Estos terminales deberán ser del tamaño apropiado para los cables que se utilicen, y tendrán que sujetar tanto el aislante como el conductor.
Varning!
När flertrådiga ledningar krävs måste godkända ledningskontakter användas, t.ex. kabelsko av sluten eller öppen typ med uppåtvänd tapp.
Storleken på dessa kontakter måste vara avpassad till ledningarna och måste kunna hålla både isoleringen och ledaren fastklämda.
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
•
General Electrical Safety Guidelines and Warnings on page 421
• DC Power Electrical Safety Guidelines
•
DC Power Disconnection Warning on page 426
•
DC Power Grounding Requirements and Warning on page 427
•
DC Power Wiring Sequence Warning on page 428
Midplane Energy Hazard Warning
WARNING: High levels of electrical energy are distributed across the midplane.
Be careful not to contact the midplane connectors, or any component connected to the midplane, with any metallic object while servicing components.
Copyright © 2018, Juniper Networks, Inc.
431
T4000 Core Router Hardware Guide
Multiple Power Supplies Disconnection Warning
WARNING: The network device has more than one power supply connection.
All connections must be removed completely to remove power from the unit completely.
Waarschuwing Deze eenheid heeft meer dan één stroomtoevoerverbinding; alle verbindingen moeten volledig worden verwijderd om de stroom van deze eenheid volledig te verwijderen.
Varoitus Tässä laitteessa on useampia virtalähdekytkentöjä. Kaikki kytkennät on irrotettava kokonaan, jotta virta poistettaisiin täysin laitteesta.
Attention Cette unité est équipée de plusieurs raccordements d'alimentation.
Pour supprimer tout courant électrique de l'unité, tous les cordons d'alimentation doivent être débranchés.
Warnung Diese Einheit verfügt über mehr als einen Stromanschluß; um Strom gänzlich von der Einheit fernzuhalten, müssen alle Stromzufuhren abgetrennt sein.
Avvertenza Questa unità ha più di una connessione per alimentatore elettrico; tutte le connessioni devono essere completamente rimosse per togliere l'elettricità dall'unità.
Advarsel Denne enheten har mer enn én strømtilkobling. Alle tilkoblinger må kobles helt fra for å eliminere strøm fra enheten.
Aviso Este dispositivo possui mais do que uma conexão de fonte de alimentação de energia; para poder remover a fonte de alimentação de energia, deverão ser desconectadas todas as conexões existentes.
¡Atención!
Esta unidad tiene más de una conexión de suministros de alimentación; para eliminar la alimentación por completo, deben desconectarse completamente todas las conexiones.
Varning!
Denna enhet har mer än en strömförsörjningsanslutning; alla anslutningar måste vara helt avlägsnade innan strömtillförseln till enheten
är fullständigt bruten.
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
•
General Electrical Safety Guidelines and Warnings on page 421
• AC Power Electrical Safety Guidelines
• DC Power Electrical Safety Guidelines
432 Copyright © 2018, Juniper Networks, Inc.
Chapter 45: Electrical Safety Guidelines and Warnings
TN Power Warning
WARNING: The device is designed to work with a TN power system.
Waarschuwing Het apparaat is ontworpen om te functioneren met TN energiesystemen.
Varoitus Koje on suunniteltu toimimaan TN-sähkövoimajärjestelmien yhteydessä.
Attention Ce dispositif a été conçu pour fonctionner avec des systèmes d'alimentation TN.
Warnung Das Gerät ist für die Verwendung mit TN-Stromsystemen ausgelegt.
Avvertenza Il dispositivo è stato progettato per l'uso con sistemi di alimentazione TN.
Advarsel Utstyret er utfomet til bruk med TN-strømsystemer.
Aviso O dispositivo foi criado para operar com sistemas de corrente TN.
¡Atención!
El equipo está diseñado para trabajar con sistemas de alimentación tipo TN.
Varning!
Enheten är konstruerad för användning tillsammans med elkraftssystem av TN-typ.
Related
Documentation
•
General Safety Guidelines and Warnings on page 393
•
General Electrical Safety Guidelines and Warnings on page 421
•
Grounded Equipment Warning on page 408
•
Multiple Power Supplies Disconnection Warning on page 432
Copyright © 2018, Juniper Networks, Inc.
433
T4000 Core Router Hardware Guide
434 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 46
Agency Approvals and Compliance
Statements
•
T4000 Agency Approvals on page 435
•
Compliance Statements for EMC Requirements on page 436
•
Compliance Statements for Environmental Requirements on page 437
•
T4000 Compliance Statements for NEBS on page 437
•
T4000 Compliance Statements for Acoustic Noise on page 438
T4000 Agency Approvals
The router complies with the following standards:
• Safety
• CAN/CSA-22.2 No. 60950–1–07/UL 60950–1, 2nd Ed., Safety of Information
Technology Equipment
• EN 60825-1 +A1+A2 (1994) Safety of Laser Products - Part 1: Equipment Classification
• EMC
• AS/NZS 3548 Class A (Australia/New Zealand)
• EN55022 Class A (Europe)
• FCC Part 15 Class A (USA)
• VCCI Class A (Japan)
• Immunity
• EN-61000-3-3 Voltage Fluctuations and Flicker
• EN-61000-4-2 ESD
• EN-61000-4-3 Radiated Immunity
• EN-61000-4-4 EFT
Copyright © 2018, Juniper Networks, Inc.
435
T4000 Core Router Hardware Guide
• EN-61000-4-5 Surge
• EN-61000-4-6 Low Frequency Common Immunity
• ETSI EN-300386-2 Telecommunication Network Equipment. Electromagnetic
Compatibility Requirements
The router is designed to comply with the following standards:
• NEBS
• GR-1089-Core: EMC and Electrical Safety for Network Telecommunications
Equipment
• SR-3580 NEBS Criteria Levels (Level 3 Compliance)
• GR-63-Core: NEBS, Physical Protection
Related
Documentation
•
T4000 Router Description on page 3
•
Compliance Statements for EMC Requirements on page 436
•
Compliance Statements for Environmental Requirements on page 437
•
T4000 Compliance Statements for NEBS on page 437
•
T4000 Compliance Statements for Acoustic Noise on page 438
Compliance Statements for EMC Requirements
•
•
European Community on page 436
•
•
•
Canada
CAN ICES-3 (A)/NMB-3(A)
European Community
This is a Class A product. In a domestic environment, this product might cause radio interference in which case the user might be required to take adequate measures.
436 Copyright © 2018, Juniper Networks, Inc.
Chapter 46: Agency Approvals and Compliance Statements
Israel
Translation from Hebrew—Warning: This product is Class A. In residential environments, the product might cause radio interference, and in such a situation, the user might be required to take adequate measures.
Japan
The preceding translates as follows:
This is a Class A product based on the standard of the Voluntary Control Council for
Interference by Information Technology Equipment (VCCI). If this product is used near a radio or television receiver in a domestic environment, it might cause radio interference.
Install and use the equipment according to the instruction manual. VCCI-A.
United States
The hardware equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, might cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Compliance Statements for Environmental Requirements
Batteries in this product are not based on mercury, lead, or cadmium substances. The batteries used in this product are in compliance with EU Directives 91/157/EEC, 93/86/EEC, and 98/101/EEC. The product documentation includes instructional information about the proper method of reclamation and recycling.
T4000 Compliance Statements for NEBS
• The equipment is suitable for installation as part of the Common Bonding Network
(CBN).
Copyright © 2018, Juniper Networks, Inc.
437
T4000 Core Router Hardware Guide
• The equipment is suitable for installation in locations where the National Electrical
Code (NEC) applies.
• The battery return connection is to be treated as an isolated DC return (i.e. DC-I), as defined in GR-1089-CORE.
Related
Documentation
•
T4000 Agency Approvals on page 435
T4000 Compliance Statements for Acoustic Noise
Maschinenlärminformations-Verordnung - 3. GPSGV, der höchste Schalldruckpegel beträgt 76.5 dB(A) oder weniger gemäss EN ISO 7779
Translation:
The emitted sound pressure resulted in 76.5 dB(A) per EN ISO 7779.
Related
Documentation
•
T4000 Agency Approvals on page 435
438 Copyright © 2018, Juniper Networks, Inc.