تبلیغات
تبلیغات
T1600 Core Router Hardware Guide
Modified: 2019-01-22
Copyright © 2019, Juniper Networks, Inc.
Juniper Networks, Inc.
1133 Innovation Way
Sunnyvale, California 94089
USA
408-745-2000 www.juniper.net
Juniper Networks, the Juniper Networks logo, Juniper, and Junos are registered trademarks of Juniper Networks, Inc. in the United States and other countries. All other trademarks, service marks, registered marks, or registered service marks are the property of their respective owners.
Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify, transfer, or otherwise revise this publication without notice.
T1600 Core Router Hardware Guide
Copyright © 2019 Juniper Networks, Inc. All rights reserved.
The information in this document is current as of the date on the title page.
YEAR 2000 NOTICE
Juniper Networks hardware and software products are Year 2000 compliant. Junos OS has no known time-related limitations through the year 2038. However, the NTP application is known to have some difficulty in the year 2036.
END USER LICENSE AGREEMENT
The Juniper Networks product that is the subject of this technical documentation consists of (or is intended for use with) Juniper Networks software. Use of such software is subject to the terms and conditions of the End User License Agreement (“EULA”) posted at https://support.juniper.net/support/eula/ . By downloading, installing or using such software, you agree to the terms and conditions of that EULA.
ii Copyright © 2019, Juniper Networks, Inc.
Table of Contents
Documentation and Release Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxix
Self-Help Online Tools and Resources . . . . . . . . . . . . . . . . . . . . . . . . . xxxii
Creating a Service Request with JTAC . . . . . . . . . . . . . . . . . . . . . . . . . . xxxiii
System Architecture Description for T Series Routers . . . . . . . . . . . . . . . . . . . . . . . 6
Packet Forwarding Engine Architecture for T Series Routers . . . . . . . . . . . . . . . . . . 8
Packet Forwarding Engine Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Chassis Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
T1600 Front Cable Management System Description . . . . . . . . . . . . . . . . . . . . . . 25
T1600 Rear Cable Management System Description . . . . . . . . . . . . . . . . . . . . . . . 25
T1600 Connector Interface Panel (CIP) Description . . . . . . . . . . . . . . . . . . . . . . . 27
T1600 Connector Interface Panel (CIP) Components . . . . . . . . . . . . . . . . . . . 27
T1600 Craft Interface LCD and Navigation Buttons . . . . . . . . . . . . . . . . . . . . . . . . 34
T1600 Craft Interface Alarm LEDs and ACO/LT Button . . . . . . . . . . . . . . . . . . . . . 35
Copyright © 2019, Juniper Networks, Inc.
iii
T1600 Core Router Hardware Guide iv
Cooling System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . 39
Host Subsystem Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . 43
MX5, MX10, MX40, and MX80 Routing Engine . . . . . . . . . . . . . . . . . . . . . . . . 62
MX2020 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
PTX10008 and PTX10016 Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . 70
TX Matrix Plus (with 3D SIBs) Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . 74
Copyright © 2019, Juniper Networks, Inc.
Table of Contents
T1600 T Series Control Boards (T-CBs) Description . . . . . . . . . . . . . . . . . . . . . . . 75
T1600 Line-Card Chassis Control Board (LCC-CB) Description . . . . . . . . . . . . . . . 77
Line Card Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
T1600 Flexible PIC Concentrator (FPC) Description . . . . . . . . . . . . . . . . . . . . . . . . 81
PIC/FPC Compatibility (Type 1 FPCs and Type 1 PICs) . . . . . . . . . . . . . . . . . 106
PIC/FPC Compatibility (Type 2 FPCs and Type 2 PICs) . . . . . . . . . . . . . . . . 108
PIC/FPC Compatibility (Type 3 FPCs and Type 3 PICs) . . . . . . . . . . . . . . . . . 110
PIC/FPC Compatibility (Type 4 FPCs and Type 4 PICs) . . . . . . . . . . . . . . . . . 111
Power System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 113
T1600 Three-Input 240-A DC Power Supply Description . . . . . . . . . . . . . . . . . . . 114
T1600 Three-Input 240-A DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . 114
T1600 Three-Input 240-A DC Power Supply Inputs . . . . . . . . . . . . . . . . . . . . 115
T1600 Three-Input 240-A DC Power Supply Load Sharing and Fault
T1600 Three-Input 240-A DC Power Supply LEDs . . . . . . . . . . . . . . . . . . . . . . . . 116
T1600 Four-Input 240-A DC Power Supply Description . . . . . . . . . . . . . . . . . . . . 117
Four-Input 240-A DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Four-Input 240-A DC Power Supply Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Four-Input 240-A DC Power Supply Load Sharing and Fault Tolerance . . . . 118
T1600 Four-Input 240-A DC Power Supply LEDs . . . . . . . . . . . . . . . . . . . . . . . . . 118
Copyright © 2019, Juniper Networks, Inc.
v
T1600 Core Router Hardware Guide
T1600 Three-Phase Delta and Wye AC Power Supply Description . . . . . . . . . . . . 121
Three-Phase Delta AC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
Three-Phase Wye AC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
AC Power Supply Load Sharing and Fault Tolerance . . . . . . . . . . . . . . . . . . . 124
T1600 Three-Phase Delta and Wye AC Power Supply LEDs . . . . . . . . . . . . . . . . 124
Switch Fabric Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 127
Site Planning, Preparation, and Specifications
T1600 Chassis Grounding Cable and Lug Specifications . . . . . . . . . . . . . . . . . . . 140
Clearance Requirements for Airflow and T1600 Hardware Maintenance . . . . . . 143
DC Power Specifications and Requirements . . . . . . . . . . . . . . . . . . . . . . . . . 145
T1600 DC Power System Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . 145
T1600 Three-Input 240-A DC Power Supply Specifications . . . . . . . . . . . . . . . . 146
T1600 Four-Input 240-A DC Power Supply Specifications . . . . . . . . . . . . . . . . . . 147
T1600 Six-Input DC Power Supply Specifications . . . . . . . . . . . . . . . . . . . . . . . . 148
AC Power Specifications and Requirements . . . . . . . . . . . . . . . . . . . . . . . . . 155
T1600 Three-Phase Delta AC Power Supply Specifications . . . . . . . . . . . . . . . . 156
T1600 Three-Phase Wye AC Power Supply Specifications . . . . . . . . . . . . . . . . . 156
vi Copyright © 2019, Juniper Networks, Inc.
Table of Contents
Network Cable and Transceiver Specifications . . . . . . . . . . . . . . . . . . . . . . . 163
Determining Transceiver Support and Specifications for M Series and T Series
Understanding Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion . . . . 164
Signal Loss in Multimode and Single-Mode Fiber-Optic Cable . . . . . . . . . . . 164
Attenuation and Dispersion in Fiber-Optic Cable . . . . . . . . . . . . . . . . . . . . . 164
Calculating Power Budget and Power Margin for Fiber-Optic Cables . . . . . . . . . 165
Calculating Power Budget for Fiber-Optic Cable . . . . . . . . . . . . . . . . . . . . . . 165
Calculating Power Margin for Fiber-Optic Cable . . . . . . . . . . . . . . . . . . . . . . 165
Management Cable Specifications and Pinouts . . . . . . . . . . . . . . . . . . . . . . 169
T1600 Routing Engine Interface Cable and Wire Specifications . . . . . . . . . . . . . 169
T1600 DB-9 Connector Pinouts for the Routing Engine AUXILIARY and CONSOLE
T1600 RJ-45 Connector Pinouts for the Routing Engine ETHERNET Port . . . . . . 170
Initial Installation and Configuration
Tools and Parts Required to Unpack the T1600 Router . . . . . . . . . . . . . . . . . . . . . 177
Installing the T1600 Mounting Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183
Installing the T1600 Mounting Hardware for a Four-Post Rack or Cabinet . . . . . 183
Removing the Center-Mounting Brackets from the Chassis . . . . . . . . . . . . . 187
Installing the T1600 Mounting Hardware for an Open-Frame Rack . . . . . . . . . . 188
Removing the Center-Mounting Brackets from the Chassis . . . . . . . . . . . . . 189
Overview of Installing the T1600 Router into the Rack . . . . . . . . . . . . . . . . . . . . . 193
Installing the T1600 Router into a Rack Using a Mechanical Lift . . . . . . . . 195
Overview of Installing a T1600 Router Using a Mechanical Lift . . . . . . . . . . . . . . 195
Tools Required to Install the T1600 Router Using a Mechanical Lift . . . . . . . . . . 196
Mounting the T1600 Chassis Using a Mechanical Lift . . . . . . . . . . . . . . . . . . . . . 198
Removing the T1600 Installation Handle and Reinstalling the Power
Copyright © 2019, Juniper Networks, Inc.
vii
T1600 Core Router Hardware Guide
Installing the T1600 Router into a Rack Without a Mechanical Lift . . . . . 203
Overview of Installing a T1600 Router Without a Mechanical Lift . . . . . . . . . . . 203
Tools and Parts Required to Install the T1600 Router Without a Mechanical
Removing Components from the T1600 Chassis . . . . . . . . . . . . . . . . . . . . . . . . 204
Removing the T1600 DC Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
Removing the T1600 AC Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . 206
Removing the T1600 Control Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
Removing the T1600 Standard or Quiet Rear Fan Tray . . . . . . . . . . . . . . . . . . 211
Removing the T1600 Front Cable Management System . . . . . . . . . . . . . . . . 212
Removing the T1600 Standard or Quiet Front Fan Trays . . . . . . . . . . . . . . . . 213
Reinstalling the T1600 Components in the Chassis . . . . . . . . . . . . . . . . . . . . . . . 220
Reinstalling the T1600 Standard or Quiet Rear Fan Tray . . . . . . . . . . . . . . . 220
Reinstalling the T1600 Control Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222
Reinstalling the T1600 Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224
Reinstalling the T1600 DC Power Supplies . . . . . . . . . . . . . . . . . . . . . . 224
Reinstalling the T1600 AC Power Supplies . . . . . . . . . . . . . . . . . . . . . . 225
Reinstalling T1600 Standard Front Fan Trays . . . . . . . . . . . . . . . . . . . . . . . . 227
Reinstalling the T1600 Front Cable Management System . . . . . . . . . . . . . . 229
Connecting the T1600 Router to Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
Tools and Parts Required to Ground the T1600 Router . . . . . . . . . . . . . . . . . . . . . 231
Connecting the T1600 Router to External Devices . . . . . . . . . . . . . . . . . . . . 235
Overview of Connecting the T1600 Router to External Devices . . . . . . . . . . . . . . 235
Tools and Parts Required to Connect the T1600 Router to External Devices . . . 236
Connecting the T1600 Router to a Management Console or Auxiliary Device . . 237
Connecting the T1600 Router to a Network for Out-of-Band Management . . . 239
Connecting the T1600 Router to an External Alarm-Reporting Device . . . . . . . . 241
Tools and Parts Required to Provide Power to the T1600 Router . . . . . . . . . . . . 245
Connecting DC Power to the T1600 Router (Three-Input 240-A DC Power
Supplies or Four-Input 240-A DC Power Supplies) . . . . . . . . . . . . . . . . . . . 246
Connecting DC Power to the T1600 Router (Six 60-A Inputs to Six-Input DC
Connecting DC Power to the T1600 Router (Five 60-A Inputs to Six-Input DC
Powering On the DC-Powered T1600 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257
viii Copyright © 2019, Juniper Networks, Inc.
Table of Contents
Connecting AC Power to a T1600 Router with Three-Phase Delta AC Power
Connecting AC Power to a T1600 Router with Three-Phase Wye AC Power
Powering On the AC-Powered T1600 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
Preparing to Configure the T1600 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . 267
Configuring User Accounts and Passwords . . . . . . . . . . . . . . . . . . . . . . . . . . 268
Configuring DC Power on a T1600 Router (Five 60-A Cables on a Six-Input
Upgrading to a T1600 Router from a T640 Router . . . . . . . . . . . . . . . . . . . . 275
Overview of Upgrading a T640 Router to a T1600 Router . . . . . . . . . . . . . . . . . . 275
Hardware Required for Upgrading from a T640 Router to a T1600 Router . . . . . 277
Verifying the Hardware Versions Before an Upgrade to a T1600 Router . . . . . . . 278
Verifying the Hardware Version of the Control Board . . . . . . . . . . . . . . . . . . 278
Verifying the Hardware Version of the Rear Fan Tray . . . . . . . . . . . . . . . . . . . 281
Verifying the Hardware Version of the Power Supplies . . . . . . . . . . . . . . . . . 283
Tools Required to Upgrade a T640 Router to a T1600 Router . . . . . . . . . . . . . . 284
Upgrading to a Supported T1600 Rear Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . 284
Removing the RHTREARTRAY-T Rear Fan Tray . . . . . . . . . . . . . . . . . . . . . . 285
Upgrading to Supported T1600 Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . 287
Removing a Two-Input 160-A DC Power Supply . . . . . . . . . . . . . . . . . . . . . . 288
Removing a Standard SIB or SIB Version B . . . . . . . . . . . . . . . . . . . . . . . . . . 293
Verifying the Installation of a T1600-SIB . . . . . . . . . . . . . . . . . . . . . . . . . . . 296
Removing the T1600 Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . 302
Reinstalling the T1600 Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . 305
Copyright © 2019, Juniper Networks, Inc.
ix
T1600 Core Router Hardware Guide x
Installing and Replacing Components
Overview of Installing and Replacing Components . . . . . . . . . . . . . . . . . . . 309
Tools and Parts Required for Replacing T1600 Hardware Components . . . . . . . 310
Removing the T1600 Alarm Relay Wires . . . . . . . . . . . . . . . . . . . . . . . . . . . . 320
Installing the T1600 Alarm Relay Wires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322
Removing a T1600 Console or Auxiliary Cable . . . . . . . . . . . . . . . . . . . . . . . 323
Installing a T1600 Console or Auxiliary Cable . . . . . . . . . . . . . . . . . . . . . . . . 325
Replacing a T1600 Management Ethernet Cable . . . . . . . . . . . . . . . . . . . . . . . . . 325
Removing a T1600 Management Ethernet Cable . . . . . . . . . . . . . . . . . . . . . 326
Installing a T1600 Management Ethernet Cable . . . . . . . . . . . . . . . . . . . . . . 327
Removing the T1600 Craft Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332
Replacing Cooling System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 337
Replacing the T1600 Standard Lower Front Fan Tray . . . . . . . . . . . . . . . . . . . . . 337
Removing the T1600 Standard Lower Front Fan Tray . . . . . . . . . . . . . . . . . . 337
Installing the T1600 Standard Lower Front Fan Tray . . . . . . . . . . . . . . . . . . 338
Replacing the T1600 Standard Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . . . 339
Removing the T1600 Standard Upper Front Fan Tray . . . . . . . . . . . . . . . . . 339
Installing the T1600 Standard Upper Front Fan Tray . . . . . . . . . . . . . . . . . . 340
Removing the T1600 Rear Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342
Upgrading the Standard Lower Front Fan Tray to a Quiet Lower Front Fan
Removing the Standard Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . 346
Installing the Air Deflector and Craft Interface . . . . . . . . . . . . . . . . . . . . . . . 348
Installing the Quiet Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . 349
Upgrading the Standard Rear Fan Tray to a Quiet Rear Fan Tray . . . . . . . . . 350
Copyright © 2019, Juniper Networks, Inc.
Table of Contents
Replacing the T1600 Quiet Lower Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . 352
Removing the T1600 Quiet Lower Front Fan Tray . . . . . . . . . . . . . . . . . . . . . 353
Installing the T1600 Quiet Lower Front Fan Tray . . . . . . . . . . . . . . . . . . . . . 354
Replacing the T1600 Quiet Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . 355
Removing the Quiet Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . 355
Installing the Quiet Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . 356
Replacing the T1600 Lower Front Fan Tray (FANTRAY-T4000) . . . . . . . . . . . . 360
Removing the T1600 Lower Front Fan Tray (FANTRAY-T4000) . . . . . . . . . 360
Installing the T1600 Lower Front Fan Tray (FANTRAY-T4000) . . . . . . . . . . 361
Replacing the T1600 Upper Front Fan Tray (FANTRAY-T4000) . . . . . . . . . . . . 362
Removing the T1600 Upper Front Fan Tray (FANTRAY-T4000) . . . . . . . . . 362
Installing the T1600 Upper Front Fan Tray (FANTRAY-T4000) . . . . . . . . . 363
Replacing Host Subsystem Components . . . . . . . . . . . . . . . . . . . . . . . . . . . 365
Removing a T1600 Routing Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374
Verifying the Installation of the T1600 Routing Engine . . . . . . . . . . . . . . . . . 378
Replacing a CompactFlash Card in a T1600 RE-C1800 Routing Engine . . . . . . . 379
Preparing to Replace a CompactFlash Card in a T1600 C1800 Routing
Removing a CompactFlash Card in a T1600 C1800 Routing Engine . . . . . . 381
Installing a CompactFlash Card in a T1600 C1800 Routing Engine . . . . . . . 382
Copying Junos OS to the CompactFlash Card in a T1600 C1800 Routing
Replacing a DIMM Module in a T1600 Routing Engine . . . . . . . . . . . . . . . . . . . . . 384
Removing a T1600 DIMM Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384
Replacing a PC Card in a T1600 Routing Engine . . . . . . . . . . . . . . . . . . . . . . . . . 386
Replacing a Solid-State Disk in a T1600 RE-C1800 Routing Engine . . . . . . . . . . 388
Preparing to Replace a Solid-State Disk in a T1600 RE-C1800 Routing
Removing a Solid-State Disk in a T1600 RE-C1800 Routing Engine . . . . . . 391
Installing a Solid-State Disk in a T1600 RE-C1800 Routing Engine . . . . . . . 392
Copying Junos OS to the Solid-State Disk in a T1600 RE-C1800 Routing
Copyright © 2019, Juniper Networks, Inc.
xi
T1600 Core Router Hardware Guide
Replacing Power System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 413
Tools and Parts Required for Replacing T1600 DC Power System
Replacing a T1600 Three-Input 240-A DC Power Supply . . . . . . . . . . . . . . . . . . 414
Removing a T1600 Three-Input 240-A DC Power Supply . . . . . . . . . . . . . . . 414
Setting the Input Mode Switch on a T1600 Three-Input 240-A DC Power
Installing a T1600 Three-Input 240-A DC Power Supply . . . . . . . . . . . . . . . 419
Replacing a Cable Restraint on the T1600 Three-Input 240-A DC Power
Removing the Standard Cable Restraint from the T1600 Three-Input
240-A Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 420
Installing the Optional Cable Restraint on the T1600 Three-Input 240-A
DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 421
Connecting a Replacement T1600 Three-Input 240-A DC Power Supply . . 422
Powering On a Replacement T1600 Three-Input 240-A DC Power
Replacing a T1600 Four-Input 240-A DC Power Supply . . . . . . . . . . . . . . . . . . . 425
Removing a T1600 Four-Input 240-A DC Power Supply . . . . . . . . . . . . . . . 425
Installing a T1600 Four-Input 240-A Power Supply . . . . . . . . . . . . . . . . . . . 429
Replacing a T1600 DC Power Supply Cable on a Three-Input 240-A DC Power
Supply or Four-Input 240-A DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . 432
Removing a T1600 DC Power Supply Cable From a Three-Input 240-A DC
Power Supply or Four-Input 240-A DC Power Supply . . . . . . . . . . . . . . 432
Installing a T1600 DC Power Supply Cable on a Three-Input 240-A DC
Power Supply or Four-Input 240-A DC Power Supply . . . . . . . . . . . . . . 435
Replacing a Front Air Filter on a T1600 AC or Three-Input 240-A or Four-Input
Removing a Front Air Filter on a T1600 AC or Three-Input 240-A or Four-Input
240-A DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 439
Installing a Front Air Filter on a T1600 AC or Three-Input 240-A or Four-Input
240-A DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 439
Replacing a T1600 Six-Input DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . 440
Removing a T1600 Six-Input DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . 441
Installing a T1600 Six-Input DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . 443
xii Copyright © 2019, Juniper Networks, Inc.
Table of Contents
Replacing a T1600 DC Power Supply Cable on a Six-Input DC Power Supply . . 446
Removing a T1600 DC Power Supply Cable From a Six-Input DC Power
Installing a T1600 DC Power Supply Cable on a Six-Input DC Power
Replacing a T1600 Six-Input DC Power Supply Front Air Filter . . . . . . . . . . . . . . 449
Removing a T1600 Six-Input DC Power Supply Front Air Filter . . . . . . . . . . 449
Installing a T1600 Six-Input DC Power Supply Front Air Filter . . . . . . . . . . . 449
Replacing a T1600 Six-Input DC Power Supply Side Air Filter . . . . . . . . . . . . . . . 449
Removing a T1600 Six-Input DC Power Supply Side Air Filter . . . . . . . . . . . 450
Installing a T1600 Six-Input DC Power Supply Side Air Filter . . . . . . . . . . . . 450
Replacing a T1600 Three-Phase Delta AC Power Supply . . . . . . . . . . . . . . . . . . . 451
Removing a T1600 Three-Phase Delta AC Power Supply . . . . . . . . . . . . . . . 452
Installing a T1600 Three-Phase Delta AC Power Supply . . . . . . . . . . . . . . . 455
Replacing a T1600 Three-Phase Delta AC Power Supply Cord . . . . . . . . . . . . . . 459
Removing a T1600 Three-Phase Delta AC Power Supply Cord . . . . . . . . . . 460
Installing a T1600 Three-Phase Delta AC Power Supply Cord . . . . . . . . . . . 462
Replacing a T1600 Three-Phase Wye AC Power Supply . . . . . . . . . . . . . . . . . . . 465
Removing a T1600 Three-Phase Wye AC Power Supply . . . . . . . . . . . . . . . 465
Installing a T1600 Three-Phase Wye AC Power Supply . . . . . . . . . . . . . . . . 468
Replacing a T1600 Three-Phase Wye AC Power Supply Cord . . . . . . . . . . . . . . . 472
Removing a T1600 Three-Phase Wye AC Power Supply Cord . . . . . . . . . . . 472
Installing a T1600 Three-Phase Wye AC Power Supply Cord . . . . . . . . . . . . 475
Replacing Switch Fabric Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 479
Verifying the Installation of a TXP-T1600 SIB . . . . . . . . . . . . . . . . . . . . . . . 486
Removing a T1600 TXP-LCC-3D SIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 488
Installing a T4000 TXP-LCC-3D SIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 490
Removing the T1600 XENPAK Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
Installing the T1600 XENPAK Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 501
Maintaining the Chassis and Components
Routine Maintenance Procedures for the T1600 Router . . . . . . . . . . . . . . . . . . . 507
Copyright © 2019, Juniper Networks, Inc.
xiii
T1600 Core Router Hardware Guide
Tools and Parts Required to Maintain the T1600 Hardware Components . . . . . 509
Maintaining the T1600 Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 521
Maintaining the T1600 Control Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 522
Cleaning Fiber-Optic Array Components with the Dry Cloth Cleaning Tool . . . . 532
Troubleshooting the T1600 Cooling System . . . . . . . . . . . . . . . . . . . . . . . . . . . . 543
Troubleshooting the T1600 Host Subsystems . . . . . . . . . . . . . . . . . . . . . . . . . . . 547
Troubleshooting the T1600 Cooling System . . . . . . . . . . . . . . . . . . . . . . . . . . . . 549
Testing a Fiber-Optic Array Switching Plane Port . . . . . . . . . . . . . . . . . . . . . . . . 559
Contacting Customer Support and Returning the Chassis or
xiv Copyright © 2019, Juniper Networks, Inc.
Table of Contents
Locating Component Serial Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 567
Locating T1600 Component Serial Numbers Using the CLI . . . . . . . . . . . . . . . . . 567
T1600 Component Serial Number Label Locations . . . . . . . . . . . . . . . . . . . . . . 569
Power Supply Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 573
Routing Engine Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 574
Packing and Returning Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 577
Tools and Parts Required to Remove Components from a T1600 Router . . . . . . 577
Packing the T1600 Router Components for Shipment . . . . . . . . . . . . . . . . . . . . 579
Returning a Hardware Component to Juniper Networks, Inc. . . . . . . . . . . . . . . . 580
Safety and Compliance Information
General Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 583
General Safety Guidelines for Juniper Networks Devices . . . . . . . . . . . . . . . . . . . 585
General Safety Warnings for Juniper Networks Devices . . . . . . . . . . . . . . . . . . . . 586
T1600 Preventing Electrostatic Discharge Damage . . . . . . . . . . . . . . . . . . . . . . . 588
Fire Safety Requirements for Juniper Networks Devices . . . . . . . . . . . . . . . . . . . 593
Installation Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . . 595
Installation Safety Warnings for Juniper Networks Devices . . . . . . . . . . . . . . . . . 595
Rack-Mounting Requirements and Warnings . . . . . . . . . . . . . . . . . . . . . . . . 597
Laser and LED Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . 603
Laser Safety Warnings for Juniper Networks Devices . . . . . . . . . . . . . . . . . . . . . 604
Radiation from Open Port Apertures Warning . . . . . . . . . . . . . . . . . . . . . . . 605
Copyright © 2019, Juniper Networks, Inc.
xv
T1600 Core Router Hardware Guide
Maintenance and Operational Safety Warnings . . . . . . . . . . . . . . . . . . . . . . 607
Maintenance and Operational Safety Warnings for Juniper Networks Devices . . 607
Electrical Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . 613
General Electrical Safety Warnings for Juniper Networks Devices . . . . . . . . . . . . 614
Grounding Requirements and Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 615
Multiple Power Supplies Disconnection Warning . . . . . . . . . . . . . . . . . . . . . 616
DC Power Electrical Safety Warnings for Juniper Networks Devices . . . . . . . . . . 619
DC Power Copper Conductors Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 619
DC Power Disconnection Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 620
DC Power Wiring Terminations Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 621
Site Electrical Wiring Guidelines for Juniper Networks Devices . . . . . . . . . . . . . . 622
Agency Approvals and Compliance Statements . . . . . . . . . . . . . . . . . . . . . 625
Compliance Statements for EMC Requirements for Juniper Networks Devices
T1600 Compliance Statements for EMC Requirements (European
Compliance Statements for EMC Requirements for Juniper Networks Devices
Compliance Statements for EMC Requirements for Juniper Networks Devices
Compliance Statements for EMC Requirements for Juniper Networks Devices
Compliance Statements for Environmental Requirements . . . . . . . . . . . . . . . . . 628
T1600 Compliance Statements for NEBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 628
T1600 Compliance Statements for Acoustic Noise . . . . . . . . . . . . . . . . . . . . . . . 628
Statements of Volatility for Juniper Network Devices . . . . . . . . . . . . . . . . . . . . . 629
xvi Copyright © 2019, Juniper Networks, Inc.
List of Figures
Figure 4: Control Packet Handling for Routing and Forwarding Table
Chassis Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Figure 10: T1600 Rear Cable Management System . . . . . . . . . . . . . . . . . . . . . . . . 26
Cooling System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . 39
Host Subsystem Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . 43
Line Card Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Copyright © 2019, Juniper Networks, Inc.
xvii
T1600 Core Router Hardware Guide xviii
Figure 31: Enhanced Scaling FPC1 Supported by the T1600 Router . . . . . . . . . . . 85
Figure 32: Standard FPC2 and FPC3 Supported by the T1600 Router . . . . . . . . . 86
Figure 33: Enhanced II FPC1, FPC2, and FPC3 Supported by the T1600 Router . . 87
Figure 34: T640 Enhanced Scaling FPC2 Supported by the T1600 Router . . . . . 88
Figure 35: T640 Enhanced Scaling FPC3 Supported by the T1600 Router . . . . . 89
Figure 36: T640 Enhanced Scaling FPC4 Supported by the T1600 Router . . . . . 90
Figure 37: T640 Enhanced Scaling FPC4-1P Supported by the T1600 Router . . . 91
Figure 38: T1600 Enhanced Scaling FPC4 Supported by the T1600 Router . . . . . 92
Power System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 113
Figure 39: Three-Input 240-A DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Figure 40: Three-Input 240-A DC Power Supply LEDs . . . . . . . . . . . . . . . . . . . . . 116
Figure 42: Four-Input 240-A DC Power Supply LEDs . . . . . . . . . . . . . . . . . . . . . . . 118
Figure 44: Three-Phase Delta AC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Figure 45: Three-Phase Delta AC Power Supply Connections . . . . . . . . . . . . . . . 122
Figure 47: Three-Phase Wye AC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Figure 48: Three-Phase Wye AC Power Supply Connections . . . . . . . . . . . . . . . . 124
Switch Fabric Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 127
Site Planning, Preparation, and Specifications
Figure 58: Chassis Dimensions and Clearance Requirements . . . . . . . . . . . . . . . 143
DC Power Specifications and Requirements . . . . . . . . . . . . . . . . . . . . . . . . . 145
AC Power Specifications and Requirements . . . . . . . . . . . . . . . . . . . . . . . . . 155
Figure 62: Three-Phase Wye AC Power Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
Initial Installation and Configuration
Installing the T1600 Mounting Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183
Copyright © 2019, Juniper Networks, Inc.
List of Figures
Figure 64: Installing the Mounting Hardware for a Four-Post Rack or Cabinet . . 185
Figure 66: Removing the Center-Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . 187
Figure 67: Installing the Mounting Hardware for an Open-Frame Rack . . . . . . . . 189
Figure 68: Removing the Center-Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . 190
Installing the T1600 Router into a Rack Using a Mechanical Lift . . . . . . . . 195
Figure 69: Removing a Three-Input 240-A DC Power Supply . . . . . . . . . . . . . . . . 197
Figure 72: Reinstalling a Three-Input 240-A DC Power Supply . . . . . . . . . . . . . . . 201
Figure 73: Reinstalling a Four-Input 240-A DC Power Supply . . . . . . . . . . . . . . . 202
Installing the T1600 Router into a Rack Without a Mechanical Lift . . . . . 203
Figure 75: Removing a Four-Input 240-A Power Supply Before Installing the
Figure 77: Removing a Three-Phase Wye AC Power Supply Before Installing the
Figure 83: Removing the Quiet Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . 214
Figure 84: Removing the Quiet Lower Front Fan Tray . . . . . . . . . . . . . . . . . . . . . . 215
Figure 93: Reinstalling a Three-Input 240-A DC Power Supply . . . . . . . . . . . . . . 225
Figure 94: Reinstalling a T1600 Four-Input 240-A DC Power Supply . . . . . . . . . 225
Figure 97: Reinstalling the Upper Front Quiet Fan Tray . . . . . . . . . . . . . . . . . . . . 229
Figure 98: Reinstalling the Lower Front Quiet Fan Tray . . . . . . . . . . . . . . . . . . . . 229
Connecting the T1600 Router to Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
Connecting the T1600 Router to External Devices . . . . . . . . . . . . . . . . . . . . 235
Figure 101: Console and Auxiliary Serial Port Connector . . . . . . . . . . . . . . . . . . . . 238
Copyright © 2019, Juniper Networks, Inc.
xix
T1600 Core Router Hardware Guide xx
Figure 103: Routing Engine Ethernet Cable Connector . . . . . . . . . . . . . . . . . . . . . 239
Figure 106: Connecting Power to the Three-Input 240-A DC Power Supply . . . . 248
Figure 107: Connecting Power to the Four-Input 240-A DC Power Supply . . . . . 249
Figure 109: Connecting Negative (–) DC Power Cables to INPUT 0, INPUT 1,
Figure 110: Connecting Negative (–) DC Power Cables to INPUT 2 and
Figure 111: Connecting Positive (+) DC Power Cables to RTN 2, RTN 5, RTN 0,
Figure 113: Connecting Negative (–) DC Power Cables to INPUT 0, INPUT 1,
Figure 114: Connecting Negative (–) DC Power Cable to INPUT 2 . . . . . . . . . . . . 256
Figure 115: Connecting Positive (+) DC Power Cable to RTN 2, RTN 0, RTN 1,
Figure 116: Connecting Power to a Three-Phase Delta AC Power Supply . . . . . . . 261
Figure 117: Connecting Power to the Three-Phase Wye AC Power Supply . . . . . . 263
Figure 118: Fastening the AC Power Cord to the Power Supply . . . . . . . . . . . . . . 264
Upgrading to a T1600 Router from a T640 Router . . . . . . . . . . . . . . . . . . . . 275
Figure 119: Removing the Rear RHTREARTRAY-T Fan Tray . . . . . . . . . . . . . . . . . 286
Figure 121: Disconnecting Power Cables from a Two-Input 160-A DC Power
Figure 123: Rear of the Power Supply Showing Midplane Connectors . . . . . . . . . 290
Figure 124: Removing a SIB from a T640 Router . . . . . . . . . . . . . . . . . . . . . . . . . 294
Figure 125: Standard SIB Supported in a T640 Router . . . . . . . . . . . . . . . . . . . . . 294
Figure 129: Installing a Replacement Craft Interface . . . . . . . . . . . . . . . . . . . . . . 305
Installing and Replacing Components
Copyright © 2019, Juniper Networks, Inc.
List of Figures
Figure 145: Installing a Replacement Craft Interface . . . . . . . . . . . . . . . . . . . . . . 333
Replacing Cooling System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 337
Figure 148: Removing a Standard Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . 340
Figure 153: Removing a Standard Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . . 347
Figure 159: Removing the Quiet Lower Front Fan Tray . . . . . . . . . . . . . . . . . . . . . 354
Figure 161: Removing the Quiet Upper Front Fan Tray . . . . . . . . . . . . . . . . . . . . . 356
Replacing Host Subsystem Components . . . . . . . . . . . . . . . . . . . . . . . . . . . 365
Copyright © 2019, Juniper Networks, Inc.
xxi
T1600 Core Router Hardware Guide xxii
Figure 188: Connecting Fiber-Optic Cable to a PIC . . . . . . . . . . . . . . . . . . . . . . . 402
Replacing Power System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 413
Figure 192: Disconnecting Power Cables from the DC Power Supply . . . . . . . . . . 415
Figure 193: Rear of the Power Supply Showing Midplane Connectors . . . . . . . . . 416
Figure 194: Removing a Three-Input 240-A DC Power Supply . . . . . . . . . . . . . . . 417
Figure 195: Three-Input 240-ADC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . 418
Figure 196: Installing a Three-Input 240-ADC Power Supply . . . . . . . . . . . . . . . . 419
Figure 197: Three-Input 240-A Power Supply with the Standard Cable
Figure 198: Three-Input 240-A Power Supply with the Optional Cable
Figure 199: Connecting DC Power Cables to the Three-Input 240-A DC Power
Supply (PWR-T1600-3-80-DC-S) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 423
Figure 200: Four-Input 240-A DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . 426
Figure 201: Disconnecting Power Cables from the Four-Input 240-A DC Power
Figure 202: Removing a Four-Input 240-A DC Power Supply . . . . . . . . . . . . . . . 428
Figure 203: Rear of the Power Supply Showing Midplane Connectors . . . . . . . . 428
Figure 204: Connecting a Power Cable to a Four-Input 240-A DC Power
Figure 205: Installing a Four-Input 240-A DC Power Supply . . . . . . . . . . . . . . . . 431
Figure 206: Disconnecting a Power Cable from a Three-Input 240-A DC Power
Figure 207: Disconnecting a Power Cable from a Four-Input 240-A DC Power
Figure 208: Connecting a Power Cable to a Three-Input 240-A DC Power
Figure 209: Connecting a Power Cable to a Four-Input 240-A DC Power
Figure 213: Disconnecting Power Cables from the DC Power Supply . . . . . . . . . 442
Figure 215: Rear of the Power Supply Showing Midplane Connectors . . . . . . . . . 443
Figure 216: Inserting the DC Power Supply into the Chassis . . . . . . . . . . . . . . . . 444
Figure 220: Removing the Power Supply Side Air Filter . . . . . . . . . . . . . . . . . . . . 450
Copyright © 2019, Juniper Networks, Inc.
List of Figures
Figure 222: Three-Phase Delta AC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . 452
Figure 223: Disconnecting the Power Cord from a Three-Phase Delta AC Power
Figure 224: Removing a Three-Phase Delta AC Power Supply . . . . . . . . . . . . . . 454
Figure 225: Rear of the Power Supply Showing Midplane Connectors . . . . . . . . 455
Figure 226: Connecting Power to a Three-Phase Delta AC Power Supply . . . . . . 457
Figure 227: Installing a Three-Phase Delta AC Power Supply . . . . . . . . . . . . . . . 459
Figure 228: Three-Phase Delta AC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . 460
Figure 229: Disconnecting the Power Cord from a Three-Phase Delta AC Power
Figure 230: Connecting Power to a Three-Phase Delta AC Power Supply . . . . . 464
Figure 231: Three-Phase Wye AC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . 466
Figure 232: Disconnecting the AC Power Cord from a Three-Phase Wye AC Power
Figure 233: Removing a Three-Phase Wye AC Power Supply . . . . . . . . . . . . . . . 468
Figure 234: Connecting Power to the Three–Phase Wye AC Power Supply . . . . 470
Figure 235: Installing a Three-Phase Wye AC Power Supply . . . . . . . . . . . . . . . . . 471
Figure 236: Three-Phase Wye AC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . 473
Figure 237: Disconnecting the AC Power Cord from a Three-Phase Wye AC Power
Figure 238: Connecting Power to the Wye 3–Phase AC Power Supply . . . . . . . . 476
Replacing Switch Fabric Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 479
Figure 247: Connecting a CXP Cable to a CXP Transceiver . . . . . . . . . . . . . . . . . 492
Figure 250: Small Form-Factor Pluggable (SFP) . . . . . . . . . . . . . . . . . . . . . . . . . 494
Maintaining the Chassis and Components
Figure 255: Do Not Carry an FPC with Only One Hand . . . . . . . . . . . . . . . . . . . . . 517
Copyright © 2019, Juniper Networks, Inc.
xxiii
T1600 Core Router Hardware Guide
Figure 264: TX Matrix Plus Fiber-Optic Array Switching Plane Loopback
Connector and Loopback Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 559
Figure 265: Fiber-Optic Array Switching Plane Loopback Connector and Loopback
Contacting Customer Support and Returning the Chassis or
Locating Component Serial Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 567
Figure 271: Serial Number Label on a T1600 Type 4 FPC . . . . . . . . . . . . . . . . . . . 572
Figure 273: Three-input 240-A Power Supply Serial Number Label . . . . . . . . . . 573
Figure 274: DC Power Supply Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . 574
Figure 275: Routing Engine Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . 574
Figure 277: Standard SIB and SIB Version B Serial Number Label . . . . . . . . . . . . 575
Figure 278: TXP-LCC-3D Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . . . 576
Safety and Compliance Information
General Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 583
Figure 279: ESD Point on Front of the T1600 Router . . . . . . . . . . . . . . . . . . . . . . 589
Figure 280: ESD Point on Rear of the T1600 Router . . . . . . . . . . . . . . . . . . . . . . 590
Figure 281: Placing a Component into an Electrostatic Bag . . . . . . . . . . . . . . . . 590
xxiv Copyright © 2019, Juniper Networks, Inc.
List of Tables
Chassis Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Table 7: Alarm LEDs and Alarm Cutoff/Lamp Test Button . . . . . . . . . . . . . . . . . . . 36
Host Subsystem Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . 43
Table 16: End-of-Life Routing Engine Specifications . . . . . . . . . . . . . . . . . . . . . . . 57
Table 22: MX5, MX10, MX40, and MX80 Routing Engine . . . . . . . . . . . . . . . . . . . . 62
Table 24: MX240 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Table 25: MX480 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Table 26: MX960 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Table 27: MX2008 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Table 28: MX2010 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Table 29: MX2020 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Table 30: MX10003 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Copyright © 2019, Juniper Networks, Inc.
xxv
T1600 Core Router Hardware Guide xxvi
Table 35: PTX10008 and PTX10016 Routing Engines . . . . . . . . . . . . . . . . . . . . . . 70
Table 42: Routing Engines on TX Matrix Plus with 3D SIBs . . . . . . . . . . . . . . . . . . 74
Line Card Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Table 47: Identifying the FPCs Supported by the T1600 Router . . . . . . . . . . . . . . 83
Table 48: FPCs Supported by the T1600 Router . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Table 49: ATM2 IQ PICs Supported by the T1600 Router . . . . . . . . . . . . . . . . . . . 96
Table 50: Channelized IQ PICs Supported by the T1600 Router . . . . . . . . . . . . . . 96
Table 51: Channelized Enhanced IQ (IQE) PICs Supported by the T1600
Table 52: DS3 and E3 PICs Supported by the T1600 Router . . . . . . . . . . . . . . . . . 97
Table 53: Fast Ethernet PICs Supported by the T1600 Router . . . . . . . . . . . . . . . 98
Table 54: Gigabit Ethernet PICs Supported by the T1600 Router . . . . . . . . . . . . . 98
Table 58: 10-Gigabit Ethernet PICs Supported by the T1600 Router . . . . . . . . . . 101
Table 59: 40-Gigabit Ethernet PICs Supported by the T1600 Router . . . . . . . . . 102
Table 60: 100-Gigabit Ethernet PICs Supported by the T1600 Router . . . . . . . . 102
Table 61: Services PICs Supported by the T1600 Router . . . . . . . . . . . . . . . . . . . 102
Table 62: SONET/SDH PICs Supported by the T1600 Router . . . . . . . . . . . . . . . 103
Table 63: End-of-Life PICs Supported in the T1600 Router . . . . . . . . . . . . . . . . . 104
Table 65: T1600 PIC/FPC Compatibility Type 2 . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Table 66: T1600 PIC/FPC Compatibility Type 3 . . . . . . . . . . . . . . . . . . . . . . . . . . 110
Power System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 113
Table 69: Components Powered by Each Three-Input 240-A DC Power Supply
Table 70: Three-Input 240-A DC Power Supply LEDs . . . . . . . . . . . . . . . . . . . . . . 116
Table 71: Components Powered by Each Four-Input 240-A DC Power Supply
Table 72: Four-Input 240-A DC Power Supply LEDs . . . . . . . . . . . . . . . . . . . . . . . 119
Table 73: Components Powered by Each Six-Input DC Power Supply Input . . . . 120
Switch Fabric Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 127
Copyright © 2019, Juniper Networks, Inc.
List of Tables
Site Planning, Preparation, and Specifications
DC Power Specifications and Requirements . . . . . . . . . . . . . . . . . . . . . . . . . 145
Table 85: Power System Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . 145
Table 87: Four-Input 240-A DC Power Supply Electrical Specifications . . . . . . . 147
Table 88: Six-Input DC Power Supply Electrical Specifications . . . . . . . . . . . . . . 148
Table 89: Typical DC Power Requirements for T1600 Components . . . . . . . . . . 149
AC Power Specifications and Requirements . . . . . . . . . . . . . . . . . . . . . . . . . 155
Table 92: T1600 AC Power System Electrical Specifications . . . . . . . . . . . . . . . . 155
Table 93: Three-Phase Delta AC Power Supply Electrical Specifications . . . . . . 156
Table 94: Three-Phase Wye AC Power Supply Electrical Specifications . . . . . . . 156
Table 96: Typical AC Power Requirements for T1600 Components . . . . . . . . . . . 157
Table 97: Three-Phase Delta and Wye AC Power Cord Specifications . . . . . . . . . 159
Network Cable and Transceiver Specifications . . . . . . . . . . . . . . . . . . . . . . . 163
Table 98: Estimated Values for Factors Causing Link Loss . . . . . . . . . . . . . . . . . . 166
Management Cable Specifications and Pinouts . . . . . . . . . . . . . . . . . . . . . . 169
Table 99: Cable and Wire Specifications for Routing Engine Management and
Initial Installation and Configuration
Installing the T1600 Mounting Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183
Table 104: Four-Post or Cabinet Rack Mounting Hole Locations . . . . . . . . . . . . . 183
Table 105: Open-Frame Rack Mounting Hole Locations . . . . . . . . . . . . . . . . . . . . 188
Copyright © 2019, Juniper Networks, Inc.
xxvii
T1600 Core Router Hardware Guide
Installing and Replacing Components
Overview of Installing and Replacing Components . . . . . . . . . . . . . . . . . . . 309
Table 107: Tools and Parts Required for Component Replacement . . . . . . . . . . . 310
Replacing Host Subsystem Components . . . . . . . . . . . . . . . . . . . . . . . . . . . 365
Table 108: Effect of Taking the Host Subsystem Offline . . . . . . . . . . . . . . . . . . . 365
Table 109: SONET/SDH Interface Alarm Messages . . . . . . . . . . . . . . . . . . . . . . . 542
Table 111: T1600 Chassis Alarm Messages for the Craft Interface . . . . . . . . . . . . 546
Table 112: T1600 Chassis Alarm Messages for Host Subsystems . . . . . . . . . . . . 547
Table 113: T1600 Chassis Alarm Messages for the Control Boards . . . . . . . . . . . 548
Table 116: Chassis Alarm Messages for the SCGs . . . . . . . . . . . . . . . . . . . . . . . . . 556
Table 117: T1600 Chassis Alarm Messages for SIBs . . . . . . . . . . . . . . . . . . . . . . . 557
Table 118: Chassis Alarm Messages for a T1600 Router in a Routing Matrix . . . . 558
xxviii Copyright © 2019, Juniper Networks, Inc.
About the Documentation
•
Documentation and Release Notes on page xxix
•
Documentation Conventions on page xxix
•
Documentation Feedback on page xxxi
•
Requesting Technical Support on page xxxii
Documentation and Release Notes
To obtain the most current version of all Juniper Networks
® technical documentation, see the product documentation page on the Juniper Networks website at https://www.juniper.net/documentation/ .
If the information in the latest release notes differs from the information in the documentation, follow the product Release Notes.
Juniper Networks Books publishes books by Juniper Networks engineers and subject matter experts. These books go beyond the technical documentation to explore the nuances of network architecture, deployment, and administration. The current list can be viewed at https://www.juniper.net/books .
Documentation Conventions
defines notice icons used in this guide.
Copyright © 2019, Juniper Networks, Inc.
xxix
T1600 Core Router Hardware Guide
Table 1: Notice Icons
Icon Meaning
Informational note
Caution
Warning
Laser warning
Tip
Best practice
Description
Indicates important features or instructions.
Indicates a situation that might result in loss of data or hardware damage.
Alerts you to the risk of personal injury or death.
Alerts you to the risk of personal injury from a laser.
Indicates helpful information.
Alerts you to a recommended use or implementation.
defines the text and syntax conventions used in this guide.
Table 2: Text and Syntax Conventions
Convention Description Examples
Bold text like this
Fixed-width text like this
Represents text that you type.
Represents output that appears on the terminal screen.
To enter configuration mode, type the configure command: user@host> configure user@host> show chassis alarms
No alarms currently active
Italic text like this
Italic text like this
•
•
• Introduces or emphasizes important new terms.
Identifies guide names.
Identifies RFC and Internet draft titles.
•
•
•
A policy term is a named structure that defines match conditions and actions.
Junos OS CLI User Guide
RFC 1997, BGP Communities Attribute
Represents variables (options for which you substitute a value) in commands or configuration statements.
Configure the machine’s domain name:
[edit] root@# set system domain-name domain-name xxx Copyright © 2019, Juniper Networks, Inc.
About the Documentation
Table 2: Text and Syntax Conventions (continued)
Convention Description
Text like this
< > (angle brackets)
| (pipe symbol)
Examples
Represents names of configuration statements, commands, files, and directories; configuration hierarchy levels; or labels on routing platform components.
•
•
To configure a stub area, include the stub statement at the [edit protocols ospf area area-id] hierarchy level.
The console port is labeled CONSOLE .
Encloses optional keywords or variables.
stub <default-metric metric >;
Indicates a choice between the mutually exclusive keywords or variables on either side of the symbol. The set of choices is often enclosed in parentheses for clarity.
broadcast | multicast
( string1 | string2 | string3 )
# (pound sign)
[ ] (square brackets)
Indention and braces ( { } )
; (semicolon)
Indicates a comment specified on the same line as the configuration statement to which it applies.
rsvp { # Required for dynamic MPLS only
Encloses a variable for which you can substitute one or more values.
Identifies a level in the configuration hierarchy.
Identifies a leaf statement at a configuration hierarchy level.
community name members [ community-ids ]
[edit] routing-options { static { route default { nexthop address; retain;
}
}
}
GUI Conventions
Bold text like this
> (bold right angle bracket)
Represents graphical user interface (GUI) items you click or select.
•
•
In the Logical Interfaces box, select
All Interfaces .
To cancel the configuration, click
Cancel .
Separates levels in a hierarchy of menu selections.
In the configuration editor hierarchy, select Protocols>Ospf .
Documentation Feedback
We encourage you to provide feedback so that we can improve our documentation. You can use either of the following methods:
• Online feedback system—Click TechLibrary Feedback, on the lower right of any page on the Juniper Networks TechLibrary site, and do one of the following:
Copyright © 2019, Juniper Networks, Inc.
xxxi
T1600 Core Router Hardware Guide
• Click the thumbs-up icon if the information on the page was helpful to you.
• Click the thumbs-down icon if the information on the page was not helpful to you or if you have suggestions for improvement, and use the pop-up form to provide feedback.
• E-mail—Send your comments to [email protected]
. Include the document or topic name, URL or page number, and software version (if applicable).
Requesting Technical Support
Technical product support is available through the Juniper Networks Technical Assistance
Center (JTAC). If you are a customer with an active J-Care or Partner Support Service support contract, or are covered under warranty, and need post-sales technical support, you can access our tools and resources online or open a case with JTAC.
• JTAC policies—For a complete understanding of our JTAC procedures and policies, review the JTAC User Guide located at https://www.juniper.net/us/en/local/pdf/resource-guides/7100059-en.pdf
.
• Product warranties—For product warranty information, visit https://www.juniper.net/support/warranty/ .
• JTAC hours of operation—The JTAC centers have resources available 24 hours a day,
7 days a week, 365 days a year.
Self-Help Online Tools and Resources
For quick and easy problem resolution, Juniper Networks has designed an online self-service portal called the Customer Support Center (CSC) that provides you with the following features:
• Find CSC offerings: https://www.juniper.net/customers/support/
• Search for known bugs: https://prsearch.juniper.net/
• Find product documentation: https://www.juniper.net/documentation/
• Find solutions and answer questions using our Knowledge Base: https://kb.juniper.net/
• Download the latest versions of software and review release notes: https://www.juniper.net/customers/csc/software/
• Search technical bulletins for relevant hardware and software notifications: https://kb.juniper.net/InfoCenter/ xxxii Copyright © 2019, Juniper Networks, Inc.
About the Documentation
• Join and participate in the Juniper Networks Community Forum: https://www.juniper.net/company/communities/
• Create a service request online: https://myjuniper.juniper.net
To verify service entitlement by product serial number, use our Serial Number Entitlement
(SNE) Tool: https://entitlementsearch.juniper.net/entitlementsearch/
Creating a Service Request with JTAC
You can create a service request with JTAC on the Web or by telephone.
• Visit https://myjuniper.juniper.net
.
• Call 1-888-314-JTAC (1-888-314-5822 toll-free in the USA, Canada, and Mexico).
For international or direct-dial options in countries without toll-free numbers, see https://support.juniper.net/support/requesting-support/ .
Copyright © 2019, Juniper Networks, Inc.
xxxiii
T1600 Core Router Hardware Guide xxxiv Copyright © 2019, Juniper Networks, Inc.
PART 1
Overview
•
System Overview and Architecture on page 3
•
T1600 Router Release Notes on page 13
•
Chassis Components and Descriptions on page 17
•
Cooling System Components and Descriptions on page 39
•
Host Subsystem Components and Descriptions on page 43
•
Line Card Components and Descriptions on page 81
•
Power System Components and Descriptions on page 113
•
Switch Fabric Components and Descriptions on page 127
Copyright © 2019, Juniper Networks, Inc.
1
T1600 Core Router Hardware Guide
2 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 1
System Overview and Architecture
•
T1600 Router Description on page 3
•
T1600 Component Redundancy on page 5
•
System Architecture Description for T Series Routers on page 6
•
Routing Engine Functions for T Series Routers on page 7
•
Packet Forwarding Engine Architecture for T Series Routers on page 8
T1600 Router Description
The T1600 Core Router is a complete routing system that provides Gigabit Ethernet,
SONET/SDH, and other high-speed interfaces for large networks and network applications, such as those supported by Internet service providers (ISPs). The T1600 router accommodates up to eight Flexible PIC Concentrators (FPCs), each of which can be configured with a variety of network media types. The router provides up to 800 gigabits per second (Gbps), full duplex (1600 Gbps of any-to-any, nonblocking, half-duplex) switching.
The router architecture cleanly separates control operations from packet forwarding operations. This design eliminates processing and traffic bottlenecks, permitting the router to achieve high performance.
• Control operations in the router are performed by the host subsystem, which runs Junos operating system (Junos OS) to handle routing protocols, traffic engineering, policy, policing, monitoring, and configuration management.
• Forwarding operations in the router are performed by the Packet Forwarding Engines, which consist of hardware, including ASICs, designed by Juniper Networks.
Application-specific integrated circuits (ASICs) are a definitive part of the router design; they enable the router to achieve data forwarding rates that match current fiber-optic capacity. The T1600 router provides up to a total of 1600 million packets per second
(Mpps) of forwarding.
and
illustrate the front and rear of a T1600 router.
Copyright © 2019, Juniper Networks, Inc.
3
T1600 Core Router Hardware Guide
Figure 1: Front View of the T1600 Router
Front-mounting flange
Center-mounting bracket
Craft interface
Fan tray
FPCs
CIP
ESD point
Air filter
Fan tray
Air intake
4 Copyright © 2019, Juniper Networks, Inc.
Figure 2: Rear View of the T1600 Router
Chapter 1: System Overview and Architecture
Related
Documentation
•
System Architecture Description for T Series Routers on page 6
•
T1600 Chassis Description on page 21
•
General Safety Guidelines for Juniper Networks Devices on page 585
T1600 Component Redundancy
The T1600 Core Router is designed so that no single point of failure can cause the entire system to fail. The following major hardware components are redundant:
• Switch Interface Boards (SIBs)—The T1600 router has five SIBs.
See
“T1600 Switch Interface Board (SIB) Description” on page 127
.
• Host subsystem—The host subsystem consists of a Routing Engine functioning together with a control board. The router can have one or two host subsystems. If two host
Copyright © 2019, Juniper Networks, Inc.
5
T1600 Core Router Hardware Guide subsystems are installed, one functions as the master and the other functions as the backup. If the master host subsystem (or either of its components) fails, the backup can take over as the master. To operate, each host subsystem requires a Routing Engine installed in an adjacent slot to a control board.
If the Routing Engines are configured for nonstop active routing, the backup Routing
Engine automatically synchronizes its configuration and state with the master Routing
Engine. Any update to the master Routing Engine state is replicated on the backup
Routing Engine. If the backup Routing Engine assumes mastership, packet forwarding continues through the router without interruption. For more information about nonstop active routing, see the High Availability Feature Guide .
NOTE: Nonstop active routing is supported for standalone T1600 routers in Junos OS Release 8.5 and later. Nonstop active routing is supported for
T1600 routers in a routing matrix in Junos OS Release 10.0 and later.
See
“T1600 Host Subsystem Description” on page 43
• SONET Clock Generators (SCGs)—The router has a standard configuration of one
SCG. A second can be purchased to function as backup. If one SCG fails, the other becomes the master SCG. Mastership of the SCGs is independent of the host subsystem, so routing functions are not affected.
See
“T1600 SONET Clock Generators Description” on page 30
.
• Power supplies—The router has two power supplies, which share the load evenly. If one power supply fails, the other power supply can provide full power to the router indefinitely.
See
“T1600 Power System Description” on page 113 .
• Cooling system—The cooling system has redundant components, which are controlled by the host subsystem. If one of the fans fails, the host subsystem increases the speed of the remaining fans to provide sufficient cooling for the router indefinitely.
See
“T1600 Cooling System Description” on page 39
.
Related
Documentation
•
System Architecture Description for T Series Routers on page 6
•
T1600 Chassis Description on page 21
•
T1600 Midplane Description on page 23
System Architecture Description for T Series Routers
The T Series Core Routers have two main architectural components:
• Routing Engine—One or more Routing Engines provide Layer 3 routing services and network management.
• Packet Forwarding Engines—These high-performance, ASIC-based components provide
Layer 2 and Layer 3 packet switching, route lookups, and packet forwarding.
6 Copyright © 2019, Juniper Networks, Inc.
Chapter 1: System Overview and Architecture
The Routing Engines and the Packet Forwarding Engines perform their primary tasks independently, although they constantly communicate through multiple 100 millions of packets per second (Mbps) links. This arrangement streamlines forwarding and routing control and runs Internet-scale backbone networks at high speeds.
shows the relationship between the Routing Engine and the Packet Forwarding Engines.
Figure 3: Router Architecture
Related
Documentation
•
Routing Engine Functions for T Series Routers on page 7
•
Packet Forwarding Engine Architecture for T Series Routers on page 8
Routing Engine Functions for T Series Routers
The Routing Engine handles all routing protocol processes, as well as the software processes that control the router's interfaces, the chassis components, system management, and user access to the router. The routing and software processes run on top of a kernel that interacts with the Packet Forwarding Engine.
The Routing Engine constructs and maintains one or more routing tables (see
Figure 4 on page 7 ). From the routing tables, the Routing Engine derives a table of active
routes, called the forwarding table, which is then copied into the Packet Forwarding
Engine. The design of the ASICs allow the forwarding table in the Packet Forwarding
Engine to be updated without interrupting forwarding performance.
Figure 4: Control Packet Handling for Routing and Forwarding Table Updates
Copyright © 2019, Juniper Networks, Inc.
7
T1600 Core Router Hardware Guide
The Routing Engine includes the following functions and features:
• Processing of routing protocol packets—The Routing Engine handles all packets that concern routing protocols, freeing the Packet Forwarding Engine to handle only packets that represent Internet traffic.
• Software modularity—Because each software process is devoted to a different function and uses a separate process space, the failure of one process has little or no effect on the others.
• In-depth Internet functionality—Each routing protocol is implemented with a complete set of Internet features and provides full flexibility for advertising, filtering, and modifying routes. Routing policies are set according to route parameters (for example, prefix, prefix lengths, and BGP attributes).
• Scalability—Junos OS routing tables have been designed to hold all the routes in current networks with ample capacity for expansion. Additionally, Junos OS can efficiently support large numbers of interfaces and virtual circuits.
• Management interface—Different levels of system management tools are provided, including the Junos OS command-line interface (CLI), the Junos XML management protocol, the craft interface, and SNMP.
• Storage and change management—Configuration files, system images, and microcode can be held and maintained in primary and secondary storage systems, permitting local or remote upgrades.
• Monitoring efficiency and flexibility—The router supports functions such as alarm handling and packet counting on every port, without degrading packet-forwarding performance.
Related
Documentation
•
System Architecture Description for T Series Routers on page 6
•
Packet Forwarding Engine Architecture for T Series Routers on page 8
Packet Forwarding Engine Architecture for T Series Routers
The Packet Forwarding Engines provide the Layer 2 and Layer 3 packet switching, forwarding, and route lookup functions. The Packet Forwarding Engines are implemented in ASICs that are physically located on the FPCs and the PICs. To ensure the efficient movement of data, the router is designed so that ASICs on the hardware components handle the forwarding of data.
•
Packet Forwarding Engine Components on page 9
•
8 Copyright © 2019, Juniper Networks, Inc.
Chapter 1: System Overview and Architecture
Packet Forwarding Engine Components
Each Packet Forwarding Engine consists of the following components:
• Layer 2/Layer 3 Packet Processing ASIC, which performs Layer 2 and Layer 3 encapsulation and decapsulation, and manages the division and reassembly of packets within the router.
• Queuing and Memory Interface ASICs, which manage the buffering of data cells in memory and the queueing of notifications.
• T Series Internet Processor, which provides the route lookup function.
• Switch Interface ASICs, which extract the route lookup key and manage the flow of data cells across the switch fabric.
Media-specific ASICs on the PICs perform control functions tailored to the PIC media types.
Data Flow
To ensure the efficient movement of data, the router is designed so that ASICs on the hardware components handle the forwarding of data. Data flows through the router in the following sequence (see
):
Figure 5: Data Flow Through the Router
Copyright © 2019, Juniper Networks, Inc.
9
T1600 Core Router Hardware Guide
10
1.
Packets arrive at an incoming PIC interface.
2.
The PIC passes the packets to the FPC, where the Layer 2/Layer 3 Packet Processing
ASIC performs Layer 2 and Layer 3 parsing and divides the packets into 64-byte cells.
3.
The Switch Interface ASIC extracts the route lookup key, places it in a notification, and passes the notification to the T Series Internet Processor. The Switch Interface
ASIC also passes the data cells to the Queuing and Memory Interface ASICs for buffering.
4.
The Queuing and Memory Interface ASICs pass the data cells to memory for buffering.
5.
The T Series Internet Processor performs the route lookup and forwards the notification to the Queuing and Memory Interface ASIC.
6.
The Queuing and Memory Interface ASIC sends the notification to the Switch Interface
ASIC facing the switch fabric, unless the destination is on the same Packet Forwarding
Engine. In this case, the notification is sent back to the Switch Interface ASIC facing the outgoing ports, and the packets are sent to the outgoing port without passing through the switch fabric (see Step
).
7.
The Switch Interface ASIC sends bandwidth requests through the switch fabric to the destination port. The Switch Interface ASIC also issues read requests to the Queuing and Memory Interface ASIC to begin reading data cells out of memory.
8.
The destination Switch Interface ASIC sends bandwidth grants through the switch fabric to the originating Switch Interface ASIC.
9.
On receipt of each bandwidth grant, the originating Switch Interface ASIC sends a cell through the switch fabric to the destination Packet Forwarding Engine.
10.
The destination Switch Interface ASIC receives cells from the switch fabric. It extracts the route lookup key from each cell, places it in a notification, and forwards the notification to the T Series Internet Processor.
11.
The T Series Internet Processor performs the route lookup, and forwards the notification to the Queuing and Memory Interface ASIC.
12.
The Queuing and Memory Interface ASIC forwards the notification, including next-hop information, to the Switch Interface ASIC.
13.
The Switch Interface ASIC sends read requests to the Queuing and Memory Interface
ASIC to read the data cells out of memory, and passes the cells to the Layer 2/Layer
3 Packet Processing ASIC.
Copyright © 2019, Juniper Networks, Inc.
Chapter 1: System Overview and Architecture
14.
The Layer 2/Layer 3 Packet Processing ASIC reassembles the data cells into packets, adds Layer 2 encapsulation, and sends the packets to the outgoing PIC interface.
15.
The outgoing PIC sends the packets out into the network.
Related
Documentation
•
System Architecture Description for T Series Routers on page 6
•
Routing Engine Functions for T Series Routers on page 7
Copyright © 2019, Juniper Networks, Inc.
11
T1600 Core Router Hardware Guide
12 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 2
T1600 Router Release Notes
•
Outstanding Issues with the T1600 Router on page 13
•
Errata with the T1600 Router Documentation on page 14
Outstanding Issues with the T1600 Router
This topic lists outstanding hardware issues with the T1600 Core Router.
• To support the 10-Gigabit Ethernet LAN/WAN PIC with Oversubscription and SFP+
(model number PD-5-10XGE-SFPP) in the T1600-FPC4-ES (part number 710-013037),
REV 13 and later is required.
T1600-FPC4-ES (part number 710-013037), REV 12 and earlier does not support the
10-Gigabit Ethernet LAN/WAN PIC with Oversubscription and SFP+ (model number
PD-5-10XGE-SFPP).
• When the C8000-RE Routing Engine is installed, the LEDs for the ETHERNET ports on the connector interface panel (CIP) have the following issues:
• Model number RE-DUO-C1800-8G (part number 740-026941 Rev 7)—The activity
LEDs, labeled ACT0 and ACT1 , for the ETHERNET ports on the connector interface panel (CIP) are always steadily green, even when no cables are connected to the ports.
For RE-DUO-C1800-8G (part number 740-026941 Rev 8) and above, the CIP LED behavior is as described in the T1600 Core Router Hardware Guide .
• Model numbers RE-DUO-C1800-8G and RE-DUO-C1800-16G—The LEDs labeled
GRN = 100M and YEL= 10M is always yellow, but the speed is always a 100-Mbps connection.
• After powering on or off a power supply, wait at least 60 seconds before turning it back off or on again.
• After a power supply is powered on, it can take up to 60 seconds for status indicators—such as LEDs on the power supply, show chassis commands, and messages on the craft interface LCD —to indicate that the power supply is functioning normally.
Ignore error indicators that appear during the first 60 seconds.
Copyright © 2019, Juniper Networks, Inc.
13
T1600 Core Router Hardware Guide
• The external clock inputs on the SONET Clock Generators (SCGs) with DB-9 ports
(model number SCG-T ) are not supported.
• The external clock inputs on the SONET Clock Generators (SCGs) with RJ-45 ports
(model number SCG-T-EC ) are supported for JUNOS OS Release 10.4 and later.
For complete information about the router, see the T1600 Core Router Hardware Guide .
For information about software issues, see the Junos OS Release Notes .
Related
Documentation
•
Errata with the T1600 Router Documentation on page 14
Errata with the T1600 Router Documentation
• The name of the T1600 Core Router PIC Guide has changed to T1600 Core Router
Interface Module Reference . Some documentation references still refer to the T1600
Core Router PIC Guide .
• The verifying operation procedure in the T1600 Router Upgrade Guide incorrectly lists
CB 0 REV 06 710-007655 KB9648 Control Board (CB-T) in the output.
NOTE: The control board shown as CB-T in the CLI output is the T640 standard control board (model number CB-L-T), which is not supported for T1600 routers, and is not the T-series control board (model number
CB-T).
user@host> show chassis hardware
Hardware inventory:
Item Version Part number Serial number Description
Chassis JN1090E5DAHA T1600
Midplane REV 02 710-017247 RC0094 T640 Backplane
FPM GBUS REV 09 710-002901 WE0156 T640 FPM Board
FPM Display REV 05 710-021387 DE4543 T1600 FPM Display
CIP REV 06 710-002895 WD8691 T-series CIP
PEM 0 Rev 06 740-017906 TE27790 Power Entry Module
3x80
PEM 1 Rev 06 740-017906 TE27779 Power Entry Module
3x80
SCG 0 REV 14 710-003423 WF1874 T640 Sonet Clock Gen.
SCG 1 REV 14 710-003423 WF1881 T640 Sonet Clock Gen.
Routing Engine 0 REV 06 740-014082 1000688671 RE-A-2000
Routing Engine 1 REV 06 740-014082 1000688739 RE-A-2000
CB 0 REV 06 710-007655 KB9648 Control Board (CB-T)
CB 1 REV 15 710-002728 HR8130 T-series Control Board
...
The following output shows two control boards displayed as T-series Control Board .
user@host> show chassis hardware
Hardware inventory:
Item Version Part number Serial number Description
Chassis JN1090E5DAHA T1600
14 Copyright © 2019, Juniper Networks, Inc.
Chapter 2: T1600 Router Release Notes
Midplane REV 02 710-017247 RC0094 T640 Backplane
FPM GBUS REV 09 710-002901 WE0156 T640 FPM Board
FPM Display REV 05 710-021387 DE4543 T1600 FPM Display
CIP REV 06 710-002895 WD8691 T-series CIP
PEM 0 Rev 06 740-017906 TE27790 Power Entry Module
3x80
PEM 1 Rev 06 740-017906 TE27779 Power Entry Module
3x80
SCG 0 REV 14 710-003423 WF1874 T640 Sonet Clock Gen.
SCG 1 REV 14 710-003423 WF1881 T640 Sonet Clock Gen.
Routing Engine 0 REV 06 740-014082 1000688671 RE-A-2000
Routing Engine 1 REV 06 740-014082 1000688739 RE-A-2000
CB 0 REV 15 710-002728 HR8130 T-series Control Board
CB 1 REV 15 710-002728 HR8131 T-series Control Board
...
Related
Documentation
•
Outstanding Issues with the T1600 Router on page 13
Copyright © 2019, Juniper Networks, Inc.
15
T1600 Core Router Hardware Guide
16 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 3
Chassis Components and Descriptions
•
T1600 Hardware Component Overview on page 17
•
T1600 Chassis Description on page 21
•
T1600 Midplane Description on page 23
•
T1600 Front Cable Management System Description on page 25
•
T1600 Rear Cable Management System Description on page 25
•
T1600 Connector Interface Panel (CIP) Description on page 27
•
T1600 Connector Interface Panel (CIP) LEDs on page 29
•
T1600 SONET Clock Generators Description on page 30
•
•
T1600 Craft Interface Description on page 33
•
T1600 Craft Interface LCD and Navigation Buttons on page 34
•
T1600 Craft Interface Alarm LEDs and ACO/LT Button on page 35
•
T1600 Craft Interface Host Subsystem LEDs on page 36
•
T1600 Craft Interface SIB LEDs on page 37
•
T1600 Craft Interface FPC LEDs on page 37
T1600 Hardware Component Overview
The T1600 Core Router supports the components in
Table 3 on page 17 , listed in
alphabetic order. The CLI Output column indicates the output as shown in the show chassis hardware command.
Table 3: T1600 Hardware Components
Component
Hardware Model
Number Hardware Label CLI Output Description
Cable management system
N/A N/A N/A
Copyright © 2019, Juniper Networks, Inc.
17
T1600 Core Router Hardware Guide
Table 3: T1600 Hardware Components (continued)
Component
Hardware Model
Number Hardware Label
Chassis N/A N/A
CLI Output
N/A
Description
“T1600 Chassis Description” on page 21
Cooling system, including fan trays and air filters
Standard rear fan tray FAN-REAR-TX-T640 None
LCC rear fan tray FAN-REAR-TXP-LCC None
FAN-R-TXP-3D-LCC
Quiet rear fan tray FAN-R
Quiet lower front fan tray
Quiet upper front fan tray
FAN-T-FBOT
FAN-T-FTOP
REAR FANTRAY
FAN-R-S
FAN-T-FBOT-S and
LOWER FANTRAY
FAN-T-FTOP-S and
UPPER FANTRAY
NOTE: Use show chassis hardware-models command.
Front Fan Tray
Air filter kit
Connector interface panel (CIP)
FANTRAY-T4000
FLTR-KIT-T640
CIP-L-T640
N/A
N/A
N/A
T-series CIP
Control board
Panel (CIP) Description” on page 27
“T1600 Control Boards Description” on page 74
CB-T
NOTE: CB-L-T is not supported.
Control Board-T
CB-LCC
NOTE: CB-LCC is required for both
RE-DUO-C1800-8G and
RE-DUO-C1800-16G.
Control Board
T-series Control Board
NOTE: The control board shown as CB-T in the CLI output is the
T640 Standard control board (model number CB-L-T), which is not supported for T1600 routers, and not the T-series control board (model number CB-T).
Boards (T-CBs) Description” on page 75
LCC Control Board
18 Copyright © 2019, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions
Table 3: T1600 Hardware Components (continued)
Component
Hardware Model
Number Hardware Label
Craft interface
FPC
CLI Output Description
CRAFT-T1600 T1600 T1600 FPM Display
See
“T1600 Flexible PIC Concentrator (FPC)
See control board and Routing Engine.
Host subsystem, including control board and Routing
Engine
Midplane N/A N/A T-series Backplane
PIC T1600 Core Router Interface Module
Reference
NOTE: The output varies depending on the PIC.
“T1600 Midplane Description” on page 23
“T1600 PIC Description” on page 94
Power system
Three-phase delta AC power supply
“T1600 Power System Description” on page 113
PWR-T-10KW-DELTA-AC N/A AC PEM 10kW US
Three-phase wye AC power supply
PWR-T-10KW-WYE-AC N/A
Three-Input 240-A DC
Power Supply
PWR-T1600-3-80-DC N/A
Four-Input 240-A DC
Power Supply
PWR-T1600-4-60-DC N/A
Six-Input DC Power
Supply
PWR-T-6-60-DC N/A
AC PEM 10kW EMEA
Power Entry Module
3x80
Power Entry Module
4x60
Power Entry Module
6x60
“T1600 Three-Phase Delta and Wye AC Power Supply
“T1600 Three-Phase Delta and Wye AC Power Supply
Power Supply Description” on page 114
Power Supply Description” on page 117
Supply Description” on page 119
Copyright © 2019, Juniper Networks, Inc.
19
T1600 Core Router Hardware Guide
Table 3: T1600 Hardware Components (continued)
Component
Hardware Model
Number Hardware Label CLI Output Description
Routing Engine
“T1600 Routing Engine Description” on page 44
RE-600-2048 N/A
RE-1600-2048 N/A
RE-3.0 or RE-3.0
(RE-600)
RE-4.0 (RE-1600)
“T1600 RE-600 Description” on page 45
RE-A-2000-4096 N/A RE-A-2000
“T1600 RE-1600 Description” on page 47
“T1600 RE-2000 Description” on page 52
RE-DUO-C1800-8G
RE-DUO-C1800-16G
NOTE: These Routing
Engines require the
LCC-CB (model number CB-LCC).
N/A
SONET Clock Generator (SCG)
RE-TXP-LCC or
RE-DUO-1800
SCG with RJ-48 ports SCG-T-EC
SCG with DB-9 ports SCG-T
Switch Interface
Board (SIB)
SONET CLOCK
GENERATOR
T640 Sonet Clock Gen.
Generators Description” on page 30
T640 Sonet Clock Gen.
SONET CLOCK
GENERATOR
“T1600 Switch Interface Board (SIB) Description” on page 127
T1600-SIB
TXP-T1600 SIB
TXP-3D-LCC
SIB-T1600
SIB-TXP-T1600
SIB-TXP-3D-LCC
Switch Interface
Board 1600
SIB-I8-SF
SWITCH
INTERFACE BOARD
MULTICHASSIS
LCC SIB
SWITCH
INTERFACE BOARD
MULTICHASSIS
LCC SIB
“T1600-SIB Description” on page 128
“TXP-T1600 SIB Description” on page 129
“TXP-T1600 SIB Description” on page 129
Related
Documentation
•
T1600 Router Description on page 3
•
T1600 Field-Replaceable Units on page 309
20 Copyright © 2019, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions
T1600 Chassis Description
The T1600 Core Router chassis is a rigid sheet metal structure that houses all the other
T1600 router components (see
and
Figure 7 on page 23 ). The chassis
measures 37.45 in. (95.1 cm) high, 31 in. (78.7 cm) deep, and 17.43 in. (44.3 cm) wide. The chassis can be installed into many types of racks or cabinets.
The chassis includes the following features (see
and
• Front-mounting flanges for mounting in a four-post rack or cabinet or front-mounting in an open-frame rack.
• Center-mounting metal brackets for center-mounting in an open-frame rack.
• Handles on each side to facilitate positioning the router in the rack. Do not use the handles to lift the router.
• Two electrostatic discharge (ESD) points (banana plug receptacles), one front and one rear.
CAUTION: Before removing or installing components of a router, attach an ESD strap to an ESD point and place the other end of the strap around your bare wrist. Failure to use an ESD strap could result in damage to the router.
WARNING: The router must be connected to earth ground during normal operation.
Copyright © 2019, Juniper Networks, Inc.
21
T1600 Core Router Hardware Guide
Figure 6: Front View of Router Chassis
Front-mounting flange
Center-mounting bracket
Craft interface
Fan tray
FPCs
CIP
ESD point
Air filter
Fan tray
Air intake
22 Copyright © 2019, Juniper Networks, Inc.
Figure 7: Rear View of Router Chassis
Chapter 3: Chassis Components and Descriptions
For chassis serial number information , see
“Locating T1600 Component Serial Numbers
Related
Documentation
•
T1600 Router Description on page 3
•
Rack Requirements for the T1600 Router on page 141
•
Installing the T1600 Chassis in the Rack Manually on page 217
•
Mounting the T1600 Chassis Using a Mechanical Lift on page 198
•
General Safety Guidelines for Juniper Networks Devices on page 585
T1600 Midplane Description
The midplane is located in the center of the chassis and forms the rear of the FPC card cage (see
Figure 8 on page 24 ). The FPCs install into the midplane from the front of the
Copyright © 2019, Juniper Networks, Inc.
23
T1600 Core Router Hardware Guide chassis, and the SIBs, Routing Engines, and control boards and SCGs install into the midplane from the rear of the chassis. The power supplies and cooling system components also connect to the midplane.
The midplane performs the following major functions:
• Data path—Data packets are transferred across the midplane from the Packet
Forwarding Engine on the originating FPC to the SIBs, and from the SIBs across the midplane to the Packet Forwarding Engine on the destination FPC.
See
“Packet Forwarding Engine Architecture for T Series Routers” on page 8 .
• Power distribution—The router power supplies are connected to the midplane, which distributes power to all the router components.
See
“T1600 Power System Description” on page 113 .
• Signal path—The midplane provides the signal path to the FPCs, SIBs, Routing Engines,
CB, and other system components for monitoring and control of the system.
Figure 8: Midplane
Midplane
FPC card cage
24 Copyright © 2019, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions
For chassis serial number information , see
“Locating T1600 Component Serial Numbers
Related
Documentation
•
T1600 Router Description on page 3
T1600 Front Cable Management System Description
The front cable management system (see
Figure 9 on page 25 ) consists of a row of nine
semicircular plastic bobbins mounted on the front of the router below the FPC card cage.
The PIC cables pass between the bobbins and into the tray, keeping the cables organized and securely in place. The curvature of the bobbins also helps maintain the proper bend radius for optical PIC cables.
You can pull the front cable management system up and outward to lock it into the maintenance position. This allows you to access the lower fan tray and the front air filter.
Figure 9: Front Cable Management System
Related
Documentation
•
T1600 Chassis Description on page 21
•
T1600 Rear Cable Management System Description on page 25
T1600 Rear Cable Management System Description
NOTE: The rear cable management system is not needed for standalone
T1600 routers with T1600-SIBs and T-CBs.
For T1600 routers connected to a TX Matrix Plus router, you can use the optional rear cable management system to organize, support, and provide strain relief for the cables connected to the TXP-T1600 or TXP-LCC-3D SIBs, and the cables connected to the
LCC-CBs. The rear cable management system consists of one cable management arm.
The cables are routed to the left side of the T1600 router, and then toward the top of the chassis, where you can route the cables to the TX Matrix Plus router. The cable
Copyright © 2019, Juniper Networks, Inc.
25
T1600 Core Router Hardware Guide management system adds 9.5 in. (24.1 cm) to the depth of the T1600 chassis, and 2.4 in.
(6.2 cm) to the left side of the chassis.
• The optional rear cable management system (model number CBL-MGR-TXP-LCC) supports the TXP-T1600 configuration and fiber-optic array cables only (see
• The LCC rear cable management system (model number CBL-MGR-TXP-3D-LCC) can be used for any configuration including TXP-T1600 configuration, TXP-T1600-3D configuration, TXP-T4000-3D configuration, and TXP-Mixed-LCC-3D configuration.
See the TX Matrix Plus Router Hardware Guide for instructions on installing and using the
T1600 rear cable management system.
Figure 10: T1600 Rear Cable Management System
Rear cable management system
26
Related
Documentation
•
T1600 Chassis Description on page 21
•
T1600 Front Cable Management System Description on page 25
Copyright © 2019, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions
T1600 Connector Interface Panel (CIP) Description
•
T1600 Connector Interface Panel (CIP) Components on page 27
•
•
T1600 Alarm Relay Contacts on page 29
T1600 Connector Interface Panel (CIP) Components
The Connector Interface Panel (CIP) consists of Ethernet, console, and auxiliary ports for the Routing Engines and alarm relay contacts (see
Copyright © 2019, Juniper Networks, Inc.
27
T1600 Core Router Hardware Guide
Figure 11: CIP
HOST
0
ETHERNET
ACT 0
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
HOST
1
ETHERNET
ACT 1
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
RED ALARM
NC
C
NO
NC
C
NO
YELLOW
ALARM
The CIP is located at the left side of the FPC card cage, above the front electrostatic discharge point. The CIP is hot-pluggable.
Management Ports
The CIP has two sets of management ports (see
Figure 11 on page 28 ) that you use to
connect the Routing Engines to external management devices. The upper set of ports, labeled HOST 0 , connects to the Routing Engine in slot RE0 ; and the lower set, labeled
HOST 1 , connects to the Routing Engine in slot RE1 . From these management devices, you can use the CLI to configure the router.
28 Copyright © 2019, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions
Each set includes the following ports:
• ETHERNET —Connects the Routing Engine through an Ethernet connection to a management LAN (or any other device that plugs into an Ethernet connection) for out-of-band management. The port uses an autosensing RJ-45 connector to support both 10- and 100-Mbps connections.
• One small LED on the upper left edge of the ETHERNET port, labeled ACT , indicates whether traffic is passing through the port.
• One small LED on the lower left edge of the ETHERNET port indicates the connection in use: the yellow LED lights for a 10-Mbps connection, and the green LED lights for a 100-Mbps connection.
NOTE: When an RE-C18000 is installed, the connection LED is always yellow for both a 10-Mbps connection and 100-Mbps connection.
• CONSOLE —Connects the Routing Engine to a system console through an RS-232
(EIA-232) serial cable.
• AUXILIARY — Connects the Routing Engine to a laptop, modem, or other auxiliary device through an RS-232 (EIA-232) serial cable.
T1600 Alarm Relay Contacts
The CIP has two alarm relay contacts for connecting the router to external alarm devices
(see
Figure 11 on page 28 ). Whenever a system condition triggers either the red or yellow
alarm on the craft interface, the alarm relay contacts are also activated. The alarm relay contacts are located below the Routing Engine ports. The terminal blocks that plug into the alarm relay contacts are supplied with the router. They accept wire of any gauge between 28-AWG and 14-AWG (0.08 and 2.08 mm
2
), which is not provided. Use the gauge of wire appropriate for the external device you are connecting.
Related
Documentation
•
T1600 Connector Interface Panel (CIP) LEDs on page 29
•
T1600 Routing Engine Interface Cable and Wire Specifications on page 169
•
T1600 RJ-45 Connector Pinouts for the Routing Engine ETHERNET Port on page 170
•
T1600 DB-9 Connector Pinouts for the Routing Engine AUXILIARY and CONSOLE Ports on page 170
T1600 Connector Interface Panel (CIP) LEDs
Two small LEDs on the left edge of the ETHERNET port indicate activity and the speed of the connection in use.
describes the functions of the LEDs.
Copyright © 2019, Juniper Networks, Inc.
29
T1600 Core Router Hardware Guide
NOTE: For routers with RE-C1800 Routing Engines, see the release notes for your router regarding more information about the LED behavior for the
ETHERNET port.
Table 4: CIP LEDs
LED
ACT 0 and ACT 1
GRN = 100M
YEL= 10M
Color
Green
--
Green
Yellow
--
State
On steadliy
Off
On steadily
On steadily
Off
Description
Traffic is passing through the port.
No traffic is passing through the port.
100-Mbps connection
10-Mbps connection
NOTE: When RE-C1800 Routing Engines are installed, the yellow LED indicates a 100-Mbps connection.
Control board is offline.
Related
Documentation
•
Outstanding Issues with the T1600 Router on page 13
•
T1600 Connector Interface Panel (CIP) Description on page 27
•
T1600 RE-C1800 Description on page 49
•
Connecting the T1600 Router to a Network for Out-of-Band Management on page 239
•
T1600 LED Overview on page 540
T1600 SONET Clock Generators Description
The SONET Clock Generators (SCGs) provide 19.44-MHz Stratum 3 clock signal for the
SONET/SDH interfaces on the router. One SCG is shipped as part of the standard router configuration, but up to two SCGs can be installed to provide redundancy. SCGs are installed into the upper rear of the chassis in the slots labeled SCG0 and SCG1 .
Backup SCGs are hot-removable and hot-insertable. Master and nonredundant SCGs are hot-pluggable.
The router supports the SCGs in
.
NOTE: Redundant SCGs must be the same model number, except during upgrade.
30 Copyright © 2019, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions
Table 5: Supported Power Supplies
Name
SCG with DB-9 ports
SCG with RJ-48 ports
Figure 12: SCG with DB-9 Ports
Model Number
SCG-T
SCG-T-EC
First Supported Junos OS
Release
5.3
10.4
Figure 13: SCG with RJ-48 ports
Online/Offline button
EXTERNAL CLOCK INPUTS
OK Fail Master
Each SCG consists of the following components:
• 19.44-MHz Stratum 3 clock.
• Field-programmable gate array (FPGA) that performs multiplexing of clock sources.
These components are located on the SCG faceplate:
• Three LEDs— OK , FAIL , and MASTER , that display the status of the SCG.
• SCG online/offline button.
• Two external clock inputs.
Copyright © 2019, Juniper Networks, Inc.
31
T1600 Core Router Hardware Guide
NOTE: Junos OS Release 10.4 and later supports the external clock inputs on the SCG with RJ-48 ports. The external clock inputs are not supported on the SONET Clock Generator (SCG) with DB-9 ports.
For information about configuring external clock synchronization for T
Series routers, see Junos OS Administration Library
• Two LEDs for each RJ-48 external clock input that display the status of the links.
Related
Documentation
•
•
Maintaining the T1600 SCGs on page 530
•
Troubleshooting the T1600 SCGs on page 556
T1600 SCG LEDs
Three LEDs, located on the SCG faceplate, display the status of the SCG.
describes the functions of the SCG LEDs. Two LINK LEDs, located on the left of each RJ-48 port, display the status of the external clock inputs links. The other
LEDs on the right of each port are not used.
NOTE: The external clock inputs on the SCG with DB-9 ports are not functional.
shows the LEDs on the SCG with RJ-48 ports.
Figure 14: SCG with RJ-48 ports
Online/Offline button
EXTERNAL CLOCK INPUTS
OK Fail Master
describes the functions of the SCG LEDs. The LINK LED is not applicable to the SCG with DB-9 ports.
32 Copyright © 2019, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions
Table 6: SCG LEDs
Label Color
OK Green
FAIL
MASTER
LINK
Yellow
Blue
Green
State
On steadily
Off
On steadily
Off
On steadily
Off
On Steadily
Off
Description
SCG is online and is functioning normally.
SCG is not online or not functioning normally.
SCG has failed.
SCG is offline or functioning normally.
SCG is functioning as master.
SCG is not functioning as the master.
Link is online and active.
No link.
Related
Documentation
•
T1600 SONET Clock Generators Description on page 30
•
Maintaining the T1600 SCGs on page 530
•
Troubleshooting the T1600 SCGs on page 556
T1600 Craft Interface Description
The craft interface allows you to view status and troubleshooting information at a glance and to perform many system control functions. It is hot-insertable and hot-removable.
The craft interface is located on the front of the T1600 Core Router above the FPCs (see
The front panel of the craft interface contains:
• A four-line LCD display, along with six navigation buttons. The LCD display operates in Idle mode or alarm mode.
• Yellow Minor Alarm LED, Red Major Critical Alarm LED and alarm cutoff/lamp test
ACO/LT button
• ONLINE/OFFLINE button for each FPC that you use to take the FPC offline and bring it online. The button is located next to the FPC LEDs on the bottom of the craft interface.
• Host Subsystem Master , OK , and FAIL LEDs
• SIB OK and FAIL LEDs
• FPC OK and FAIL LEDs for the fans
Copyright © 2019, Juniper Networks, Inc.
33
T1600 Core Router Hardware Guide
Figure 15: Front Panel of the Craft Interface
Red alarm
LED
Yellow alarm
LED
LCD display
Host subsystem
LEDs
SIB
LEDs
FAIL
FPC 0
OK
ACO/LT
FAIL
FPC 1
OK
MENU
ENTER
FAIL
FPC 2
OK FAIL
FPC 3
OK FAIL
FPC 4
OK FAIL
FPC 5
OK
FAIL
FAIL
OK MASTER
HOST0
OK MASTER
HOST1
FAIL
FPC 6
OK
SP0
SP1
SP2
SP3
SP4
FAIL OK
FAIL
FPC 7
OK
FPC LEDs and online/offline buttons
Related
Documentation
•
T1600 Craft Interface LCD and Navigation Buttons on page 34
•
T1600 Craft Interface Alarm LEDs and ACO/LT Button on page 35
•
T1600 Craft Interface Host Subsystem LEDs on page 36
•
T1600 Craft Interface SIB LEDs on page 37
•
T1600 Craft Interface FPC LEDs on page 37
•
Troubleshooting the T1600 Craft Interface on page 546
T1600 Craft Interface LCD and Navigation Buttons
A four-line LCD is located in the craft interface, along with six navigation buttons. The
LCD operates in two modes:
• LED idle mode
• LED alarm mode
During normal operation, the LCD operates in idle mode and reports current status information, as shown in
Figure 16: LCD in Idle Mode
34
The lines in the display report the following information:
• First line—Router name.
• Second line—Length of time the router has been running, reported in the following form:
Up days + hours:minutes
Copyright © 2019, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions
• Third and fourth lines—Status messages, which rotate at 2-second intervals. Some conditions, such as removal or insertion of a system component, can interrupt the messages.
To add a message that alternates every 2 seconds with the default status messages, use the set chassis display message command. For more information, see set chassis display message .
When a red or yellow alarm occurs, the LCD switches to alarm mode and reports the alarm condition, as shown in
.
Figure 17: LCD in Alarm Mode
The lines in the display report the following information:
• First line—Router name.
• Second line—Number of active alarms.
• Third and fourth lines—Individual alarm messages, with the most severe condition shown first. The prefix on each line indicates whether the alarm is a red ( R ) or yellow ( Y ) alarm.
Related
Documentation
•
T1600 Craft Interface Description on page 33
•
T1600 LED Overview on page 540
•
T1600 Alarm Messages Overview on page 542
T1600 Craft Interface Alarm LEDs and ACO/LT Button
Two large alarm LEDs are located at the upper left of the craft interface . The circular red LED lights to indicate a critical condition that can result in a system shutdown. The triangular yellow LED lights to indicate a less severe condition that requires monitoring or maintenance. Both LEDs can be lit simultaneously.
A condition that causes an LED to light also activates the corresponding alarm relay contact on the connector interface panel (CIP). The LCD on the craft interface reports the cause of the alarm.
To deactivate red and yellow alarms, press the button labeled ACO/LT (for “alarm cutoff/lamp test”), which is located to the right of the alarm LEDs. Deactivating an alarm turns off both LEDs and deactivates the device attached to the corresponding alarm relay contact on the CIP. However, the LCD continues to report the alarm message until you clear the condition that caused the alarm.
Copyright © 2019, Juniper Networks, Inc.
35
T1600 Core Router Hardware Guide
describes the alarm LEDs and alarm cutoff button in more detail.
Table 7: Alarm LEDs and Alarm Cutoff/Lamp Test Button
Shape Color State Description
Red
Yellow
On steadily Critical alarm LED—Indicates a critical condition that can cause the router to stop functioning. Possible causes include component removal, failure, or overheating.
On steadily Warning alarm LED—Indicates a serious but nonfatal error condition, such as a maintenance alert or a significant increase in component temperature.
— — Alarm cutoff/lamp test button—Deactivates red and yellow alarms. Causes all LEDs on the craft interface to light (for testing purposes), when pressed and held.
Related
Documentation
•
T1600 Craft Interface Description on page 33
•
T1600 Connector Interface Panel (CIP) Description on page 27
•
T1600 Craft Interface LCD and Navigation Buttons on page 34
•
T1600 Alarm Messages Overview on page 542
T1600 Craft Interface Host Subsystem LEDs
Each host subsystem has three LEDs, located on the upper right of the craft interface, that indicate its status. The LEDs labeled HOST0 show the status of the Routing Engine in slot RE0 and the CB in slot CB0 . The LEDs labeled HOST1 show the status of the Routing
Engine in slot RE1 and the CB in slot CB1 .
describes the functions of the host subsystem LEDs.
Table 8: T1600 Host Subsystem LEDs
Label Color State Description
FAIL Red
Green
On steadily Host is offline.
On steadily Host is online and is functioning normally.
OK
MASTER Green On steadily Host is functioning as the master.
Related
Documentation
•
T1600 Host Subsystem Description on page 43
•
T1600 Craft Interface Description on page 33
•
•
36 Copyright © 2019, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions
•
•
•
T1600 LED Overview on page 540
T1600 Craft Interface SIB LEDs
Each SIB has two LEDs on the craft interface that indicate its status. The SIB LEDs, labeled
SIB0 through SIB2 , are located on the upper right of the craft interface. The ACTIVE LED on the SIB faceplate is not replicated on the craft interface.
describes the functions of the SIB LEDs.
Table 9: SIB LEDs on the Craft Interface
Label Color State Description
FAIL
OK
Red
Green
On steadily SIB has failed.
On steadily SIB is functioning normally.
Related
Documentation
•
T1600 Switch Interface Board (SIB) Description on page 127
•
T1600 Craft Interface Description on page 33
•
Maintaining the T1600 SIBs on page 531
•
Troubleshooting the T1600 SIBs on page 557
T1600 Craft Interface FPC LEDs
Each FPC slot has two LEDs that indicate its status. The FPC LEDs, labeled FPC0 through
FPC7 , are located along the bottom of the craft interface.
describes the functions of the FPC LEDs.
Table 10: FPC LEDs
Label Color State Description
Red On steadily FPC has failed.
FAIL
OK Green On steadily FPC is functioning normally.
Blinking FPC is starting up.
Related
Documentation
•
T1600 Flexible PIC Concentrator (FPC) Description on page 81
•
T1600 Craft Interface Description on page 33
•
Maintaining T1600 FPCs on page 514
Copyright © 2019, Juniper Networks, Inc.
37
T1600 Core Router Hardware Guide
•
Troubleshooting the T1600 FPCs on page 551
38 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 4
Cooling System Components and
Descriptions
•
T1600 Cooling System Description on page 39
T1600 Cooling System Description
The cooling system components work together to keep all router components within the acceptable temperature range. The host subsystem monitors the temperature of the router components. When the router is operating normally, the fans function at lower than full speed. If a fan fails or the ambient temperature rises above a threshold, the speed of the remaining fans is automatically adjusted to keep the temperature within the acceptable range. If the ambient maximum temperature specification is exceeded and the system cannot be adequately cooled, the Routing Engine shuts down some or all of the hardware components.
•
•
•
•
Power Supply Cooling System on page 42
Airflow
shows the airflow through the router.
Copyright © 2019, Juniper Networks, Inc.
39
T1600 Core Router Hardware Guide
Figure 18: Airflow Through the Chassis
Fan Trays
40
NOTE: The standard fan trays and quiet fan trays are not interchangeable with each other. All fans in the chassis must be either standard fan trays or quiet fan trays.
The cooling system contains the following fan trays:
• One rear fan tray cools the components installed in the rear card cage (the Routing
Engines, control boards, SCGs, and SIBs). The T1600 router supports the following rear fan trays:
• The standard rear fan tray, supported by Junos OS 8.5 and later, contains eight fans.
It has no label and is not interchangeable with the standard front fan trays.
• The quiet rear fan tray, labeled REAR FANTRAY FAN-R-S and supported by Junos
OS 11.1 and later, contains eight fans and is not interchangeable with the quiet front fan trays.
• One upper front fan tray and one lower front fan tray that cool the components installed in the front card cage (the FPCs, PICs, CIP, and midplane). The T1600 router supports the following front fan trays:
• The upper and lower standard front fan trays, each of which contains six fans and has no labels. Both standard fan trays are interchangeable with each other.
• Each quiet front fan tray contains four fans, as indicated by the four fan icons on the faceplate, and is supported by Junos OS 11.1 and later.
NOTE: The quiet upper front fan tray and quiet lower front fan tray are not interchangeable with each other. In addition to the labels, the quiet upper fan tray also has an upward pointing arrow above the four fan icons on the faceplate.
Copyright © 2019, Juniper Networks, Inc.
Chapter 4: Cooling System Components and Descriptions
The quiet upper front fan tray is labeled FAN-T-FTOP-S and UPPER FANTRAY (see
).
Figure 19: Quiet Upper Front Fan Tray
FAN-T-FTOP-S
UPPER FANTRAY
The quiet lower front fan tray is labeled FAN-T-FBOT-S and LOWER FANTRAY (see
Figure 20: Quiet Lower Front Fan Tray
FAN-T-FBOT-S
LOWER FANTRAY
• To upgrade from a standalone T1600 router or from a T1600 LCC with TXP-T1600
SIBs, the FANTRAY-T4000 front fan trays are required. The rear fan tray (model number
FAN-R-TXP-3D-LCC) contains 16 fans and is required for LCCs with TXP-LCC-3D SIBs
). The FANTRAY-T4000 front fan tray and FAN-R-TXP-3D-LCC rear fan tray are supported in Junos 13.1 and later.
Figure 21: Rear Fan Tray (FAN-R-TXP-3D-LCC)
All fan trays are hot-insertable and hot-removable.
Copyright © 2019, Juniper Networks, Inc.
41
T1600 Core Router Hardware Guide
Air Filters
The cooling system contains a front air filter and a rear air filter. All air filters are hot-insertable and hot-removable.
Power Supply Cooling System
The power supply cooling system consists of the following:
• Each DC power supply contains one fan that cools that power supply.
• Each AC power supply contains two fans that cool that power supply.
Related
Documentation
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
•
Maintaining the T1600 Air Filters on page 510
•
Maintaining the T1600 Air Intake Vents on page 510
•
Maintaining the T1600 Fan Trays on page 512
•
Troubleshooting the T1600 Cooling System on page 543
•
T1600 Physical Specifications on page 139
42 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 5
Host Subsystem Components and
Descriptions
•
T1600 Host Subsystem Description on page 43
•
T1600 Routing Engine Description on page 44
•
T1600 RE-600 Description on page 45
•
•
T1600 RE-1600 Description on page 47
•
•
T1600 RE-C1800 Description on page 49
•
T1600 RE-C1800 LEDs on page 51
•
T1600 RE-2000 Description on page 52
•
•
Routing Engine Specifications on page 54
•
Supported Routing Engines by Router on page 59
•
T1600 Control Boards Description on page 74
•
T1600 T Series Control Boards (T-CBs) Description on page 75
•
•
T1600 Line-Card Chassis Control Board (LCC-CB) Description on page 77
•
T1600 Host Subsystem Description
The host subsystem provides the routing and system management functions of the router. You can install one or two host subsystems on the router. The host subsystem consists of a Routing Engine and an adjacent control board. To operate, each host subsystem functions as a unit; the Routing Engine requires the corresponding control board, and vice versa.
Copyright © 2019, Juniper Networks, Inc.
43
T1600 Core Router Hardware Guide
NOTE: We recommend that you install two host subsystems for redundant protection. If you install only one host subsystem, we recommend that you install it in slots RE0 and CB0 .
Each host subsystem has three LEDs, located on the upper right of the craft interface, that display its status. In addition, there are LEDs on each Routing Engine and control board.
Related
Documentation
•
T1600 Routing Engine Description on page 44
•
T1600 Control Boards Description on page 74
•
T1600 Craft Interface Host Subsystem LEDs on page 36
T1600 Routing Engine Description
The Routing Engine runs Junos OS. Software processes that run on the Routing Engine maintain the routing tables, manage the routing protocols used on the T1600 Core Router, control the T1600 router interfaces, control some chassis components, and provide the interface for system management and user access to the router.
You can install one or two Routing Engines in the router. The Routing Engines install into the upper rear of the chassis in the slots labeled RE0 and RE1 . Each Routing Engine requires a control board to be installed in the adjacent slot.
RE0 installs below CB0 , and RE1 installs above CB1 . A Routing Engine does not power up without a control board present in the adjacent slot.
If two Routing Engines are installed, one functions as the master and the other acts as the backup. If the master Routing Engine fails or is removed and the backup is configured appropriately, the backup takes over as the master. If the host system is redundant, the backup Routing Engine is hot-removable and hot-insertable, but the master Routing
Engine is hot-pluggable. A Routing Engine that is not redundant requires that you power down the router before replacement.
NOTE: For specific information about Routing Engine components (for example, the amount of DRAM), issue the show chassis routing-engine command.
The ports for connecting the Routing Engine to external management devices are located on the Connector Interface Panel (CIP).
NOTE: If two Routing Engines are installed, they must both be the same hardware model, except during upgrade.
The T1600 router supports the Routing Engines listed in
44 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 11: T1600 Supported Routing Engines
Name Model Number
RE-600 (EOL)
“T1600 RE-600 Description” on page 45
RE-600-2048
RE-1600-2048 RE-1600 (EOL)
“T1600 RE-1600 Description” on page 47
RE-A-2000-4096 RE-2000
“T1600 RE-2000 Description” on page 52
RE-C1800
“T1600 RE-C1800 Description” on page 49
NOTE: The RE-C1800 is required for connection to a TX Matrix Plus router.
These Routing Engines require the
LCC-CB.
RE-DUO-C1800-8G
RE-DUO-C1800-16G
First Supported Junos OS
Release
8.5
8.5
8.5
9.6R2 for routers in a routing matrix
11.1 for standalone T1600 routers.
11.4R2
Related
Documentation
•
Routing Engine Functions for T Series Routers on page 7
•
T1600 Hardware Component Overview on page 17
•
Maintaining the T1600 Routing Engines on page 521
T1600 RE-600 Description
The RE-600 boots from the storage media in this order: the PC Card (if present), then the CompactFlash card (if present), then the hard disk.
Figure 22: Routing Engine 600
Copyright © 2019, Juniper Networks, Inc.
45
T1600 Core Router Hardware Guide
46
Each Routing Engine 600 (shown in
Figure 22 on page 45 ) consists of the following
components:
• CPU—Runs Junos OS to maintain the router's routing tables and routing protocols. It has a Pentium-class processor.
• SDRAM—Provides storage for the routing and forwarding tables and for other Routing
Engine processes.
• CompactFlash card—Provides primary storage for software images, configuration files, and microcode. The fixed CompactFlash card is inaccessible from outside the router.
• Hard disk—Provides secondary storage for log files, memory dumps, and rebooting the system if the CompactFlash card fails.
• EEPROM—Stores the serial number of the Routing Engine.
• Interfaces for out-of-band management access—Provide information about
Routing Engine status to devices (console, laptop, or terminal server) connected to ports located on the Connector Interface Panel (CIP).
NOTE: The router's management Ethernet interface fxp0 is the interface for connecting network devices to the router through the ETHERNET port on the connector interface panel (CIP). Junos OS automatically creates fxp0 , but you must configure its logical interface, fxp0.0
, with a valid IP address before you can use fxp0 as a management port.
The faceplate of the Routing Engine 600 contains the following:
• One PC Card slot—Accepts a removable PC Card, which stores software images for system upgrades.
A slot labeled PC CARD on the Routing Engine faceplate accepts a Type I PC Card, as defined in the PC Card Standard published by the Personal Computer Memory Card
International Association (PCMCIA). The TX Matrix router is shipped with a PC Card that contains Junos OS. The PC Card can be used to copy Junos OS from the PC Card onto the Routing Engine. You can also copy Junos OS from the Routing Engine onto a
PC Card, for example, to create a backup copy of upgrade software that you have obtained from Juniper Networks. Instructions for copying software to a PC Card are available at the Juniper Networks Support Web site ( https://www.juniper.net/support/ ); after logging in, navigate to the Customer Support Center, then to the download page for Junos OS.
NOTE: The software on a PC Card is loaded only onto the Routing Engine into which the PC Card is inserted. It is not automatically copied to the other Routing Engine.
• Reset button—Reboots the Routing Engine when pressed.
• HD LED.
Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Related
Documentation
•
T1600 Routing Engine Description on page 44
•
•
Maintaining the T1600 Host Subsystem on page 520
•
Maintaining the T1600 Routing Engines on page 521
•
Troubleshooting the T1600 Host Subsystems on page 547
T1600 RE-600 LEDs
The HD LED indicates activity on the hard drive. It does not necessarily indicate routing-related activity.
NOTE: The LEDs that report host module status (including Routing Engine status) are on the craft interface rather than the Routing Engine faceplate.
Related
Documentation
•
T1600 Routing Engine Description on page 44
•
T1600 RE-600 Description on page 45
•
Maintaining the T1600 Host Subsystem on page 520
•
Maintaining the T1600 Routing Engines on page 521
•
Troubleshooting the T1600 Host Subsystems on page 547
T1600 RE-1600 Description
The RE-1600 boots from the storage media in this order: the PC Card in SLOT 0 (if present), then the PC Card in SLOT 1 (if present), then the CompactFlash card (if present), then the hard disk.
Figure 23: Routing Engine 1600 (RE-1600)
Each RE-1600 (shown in
Figure 23 on page 47 ) consists of the following components:
Copyright © 2019, Juniper Networks, Inc.
47
T1600 Core Router Hardware Guide
48
• CPU—Runs Junos OS to maintain the router's routing tables and routing protocols. It has a Pentium-class processor.
• SDRAM—Provides storage for the routing and forwarding tables and for other Routing
Engine processes.
• CompactFlash card—Provides primary storage for software images, configuration files, and microcode. The CompactFlash card is inaccessible from outside the router.
• Hard disk—Provides secondary storage for log files, memory dumps, and rebooting the system if the CompactFlash card fails.
• EEPROM—Stores the serial number of the Routing Engine.
• Interfaces for out-of-band management—Provide information about Routing Engine status to devices (console, laptop, or terminal server) connected to the Routing Engine ports located on the CIP.
NOTE: The router's management Ethernet interface fxp0 is the interface for connecting network devices to the router through the ETHERNET port on the connector interface panel (CIP). Junos OS automatically creates fxp0 , but you must configure its logical interface, fxp0.0
, with a valid IP address before you can use fxp0 as a management port.
The faceplate of the RE-1600 contains the following:
• Two PC Card slots—Accept removable PC Cards, which store software images for system upgrades.
Each PC Card slot accepts a Type I PC Card, as defined in the PC Card Standard published by the Personal Computer Memory Card International Association (PCMCIA).
The TX Matrix router is shipped with a PC Card that contains Junos OS. The PC Card can be used to copy Junos OS from the PC Card onto the Routing Engine. You can also copy Junos OS from the Routing Engine onto a PC Card, for example, to create a backup copy of upgrade software that you have obtained from Juniper Networks. Instructions for copying software to a PC Card are available at the Juniper Networks Support Web site ( https://www.juniper.net/support/ ); after logging in, navigate to the Customer
Support Center, then to the download page for Junos OS.
NOTE: The software on a PC Card is loaded only onto the Routing Engine into which the PC Card is inserted. It is not automatically copied to the other Routing Engine.
• Reset button—Reboots the Routing Engine when pressed.
• LEDs— HD and Slot LEDs 0 and 1 — indicate activity on the hard drive or PC Cards.
NOTE: The LEDs on the Routing Engine do not necessarily indicate routing-related activity.
Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
NOTE: The LEDs that report host module status (including Routing Engine status) are on the craft interface rather than the Routing Engine faceplate.
Related
Documentation
•
T1600 Routing Engine Description on page 44
•
•
Maintaining the T1600 Host Subsystem on page 520
•
Maintaining the T1600 Routing Engines on page 521
•
Troubleshooting the T1600 Host Subsystems on page 547
T1600 RE-1600 LEDs
Table 12: RE-1600 LEDs
Label Color
describes the functions of these LEDs.
State Description
HD Indicates activity on the hard drive.
Slot LEDs 0 and 1
Yellow On steadily or blinking
Red and green alternately
Blinking
Green On steadily
Indicates that the Routing Engine is booting and the firmware is checking if a PC card is installed.
Indicates that the Routing Engine booted from the PC Card.
Related
Documentation
•
T1600 Routing Engine Description on page 44
•
T1600 RE-1600 Description on page 47
•
Maintaining the T1600 Host Subsystem on page 520
•
Maintaining the T1600 Routing Engines on page 521
•
Troubleshooting the T1600 Host Subsystems on page 547
T1600 RE-C1800 Description
NOTE: These Routing Engines require the LCC-CB.
•
RE-C1800 Components on page 50
•
RE-C1800 Boot Order on page 51
Copyright © 2019, Juniper Networks, Inc.
49
T1600 Core Router Hardware Guide
RE-C1800 Components
Each RE-C1800 ( Figure 24 on page 50
) consists of the following components:
• CPU—Runs Junos OS to maintain the routing tables and routing protocols.
• DRAM—Provides storage for the routing and forwarding tables and for other Routing
Engine processes.
• EEPROM—Stores the serial number of the Routing Engine.
• Interfaces for management access—Provide information about Routing Engine status to devices (console, laptop, or terminal server) connected to the management ports located on the CIP.
NOTE: The router's management Ethernet interface em0 is the interface for connecting network devices to the router through the ETHERNET port on the connector interface panel (CIP). Junos OS automatically creates em0 , but you must configure its logical interface, em0.0
, with a valid IP address before you can use em0 as a management port.
Figure 24: RE-C1800
The faceplate of the RE-C1800 contains the following:
• USB port—Provides a removable media interface through which you can install Junos
OS manually. Junos OS supports USB version 1.1 and version 2.0 devices.
• CompactFlash card slot—Provides primary storage for software images, configuration files, and microcode.
• Two solid-state disk (SSD) slots—Provides secondary storage for log files, memory dumps, and rebooting the system if the CompactFlash card fails.
NOTE: DISK2 is not currently supported.
• Reset button—Reboots the Routing Engine when pressed.
• Offline button—Takes the Routing Engine offline when pressed.
• Four LEDs— CF , ONLINE , ONLINE , and ONLINE .
• Extractor clips—Control the locking system that secures the Routing Engine.
50 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
RE-C1800 Boot Order
The RE-C1800 Routing Engine boots from the storage media in this order: the USB device, then the CompactFlash card (if present), then DISK1 , then the LAN.
Related
Documentation
•
T1600 Routing Engine Description on page 44
•
T1600 RE-C1800 LEDs on page 51
•
T1600 Line-Card Chassis Control Board (LCC-CB) Description on page 77
•
Maintaining the T1600 Host Subsystem on page 520
•
Maintaining the T1600 Routing Engines on page 521
•
Troubleshooting the T1600 Host Subsystems on page 547
T1600 RE-C1800 LEDs
shows the RE-C1800 LEDs.
describes the functions of the LEDs on the faceplate of the Routing Engine.
Figure 25: RE-C1800 LEDs
CF
D
I
S
K
1
D
I
S
K
2
USB
Online
CF
S
K
D
I
1
S
K
D
I
2
USB
Offline
Online
Reset
Reset
NOTE: The LEDs on the Routing Engine do not necessarily indicate routing-related activity.
Table 13: Routing Engine C1800 LEDs
Label Color State
CF Green On steadily
— Off
Description
Indicates disk activity on the CompactFlash card.
There is no disk activity on the CompactFlash card.
Copyright © 2019, Juniper Networks, Inc.
51
T1600 Core Router Hardware Guide
Table 13: Routing Engine C1800 LEDs (continued)
Label Color State Description
DISK1
DISK2
ONLINE
USB
Green
—
Green
—
Green
Red
—
Green
On steadily
Off
On steadily
Off
On steadily
On steadily
Off
On steadily
Indicates activity for the disk.
There is no activity for the disk.
Not applicable.
NOTE: The DISK2 LEDis not currently supported.
Routing Engine is functioning normally.
Routing Engine is not functioning normally.
Routing Engine is not online or not functioning normally.
Indicates activity on the USB port.
— Off There is no activity on the USB port.
Related
Documentation
•
T1600 Routing Engine Description on page 44
•
T1600 RE-C1800 Description on page 49
•
Maintaining the T1600 Host Subsystem on page 520
•
Maintaining the T1600 Routing Engines on page 521
•
Troubleshooting the T1600 Host Subsystems on page 547
T1600 RE-2000 Description
The RE-2000 boots from the storage media in this order: the USB device, then the
CompactFlash card (if present), then the hard disk, then the LAN.
Figure 26: Routing Engine 2000 (RE-2000)
52
Each RE-2000 (shown in
) consists of the following components:
Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
• CPU—Runs Junos OS to maintain the routing tables and routing protocols. It has a
Pentium-class processor.
• DRAM—Provides storage for the routing and forwarding tables and for other Routing
Engine processes.
• CompactFlash card—Provides primary storage for software images, configuration files, and microcode. The CompactFlash card is inaccessible from outside the router.
• Hard disk—Provides secondary storage for log files, memory dumps, and rebooting the system if the CompactFlash card fails.
• EEPROM—Stores the serial number of the Routing Engine.
• Interfaces for out-of-band management access—Provide information about
Routing Engine status to devices (console, laptop, or terminal server) connected to the Routing Engine ports located on the CIP.
NOTE: The router's management Ethernet interface fxp0 is the interface for connecting network devices to the router through the ETHERNET port on the connector interface panel (CIP). Junos OS automatically creates fxp0 , but you must configure its logical interface, fxp0.0
, with a valid IP address before you can use fxp0 as a management port.
The faceplate of the RE-2000 contains the following:
• USB port—Provides a removable media interface through which you can install Junos
OS manually. Junos OS supports USB version 1.0.
• Reset button—Reboots the Routing Engine when pressed.
• Offline button—Takes the Routing Engine offline when pressed.
• Extractor clips—Control the locking system that secures the Routing Engine.
• LEDs— HDD and ONLINE indicate activity on the hard disk drive and the status of the
Routing Engine.
Related
Documentation
•
T1600 Routing Engine Description on page 44
•
•
Maintaining the T1600 Host Subsystem on page 520
•
Maintaining the T1600 Routing Engines on page 521
•
Troubleshooting the T1600 Host Subsystems on page 547
T1600 RE-2000 LEDs
describes the functions of the LEDs on the faceplate of the Routing
Engine.
Copyright © 2019, Juniper Networks, Inc.
53
T1600 Core Router Hardware Guide
NOTE: The LEDs on the Routing Engine do not necessarily indicate routing-related activity.
Table 14: Routing Engine 2000 LEDs
Label Color State
Blue On steadily HDD
ONLINE Green
Red
On steadily
Blinking
On steadily
Description
Indicates disk activity for the hard disk drive.
Routing Engine is functioning normally.
Routing Engine is transitioning online.
Routing Engine has failed.
Related
Documentation
•
T1600 Routing Engine Description on page 44
•
T1600 RE-2000 Description on page 52
•
Maintaining the T1600 Host Subsystem on page 520
•
Maintaining the T1600 Routing Engines on page 521
•
Troubleshooting the T1600 Host Subsystems on page 547
Routing Engine Specifications
lists the current specifications for Routing Engines supported on
M Series, MX Series, and T Series routers.
lists the specifications for end-of-life Routing Engines.
NOTE: For a list of the routing engines that are supported on the M Series,
MX Series, T Series, and PTX routers, see
NOTE: For information about PTX Series Routing Engine specifications, see
Routing Engines Supported on PTX Series Routers. For information about
Table 15: Routing Engine Specifications
Routing
Engine Processor Memory
Connection to PFEs Disk
RE-400-768 400-MHz
Celeron
768 MB Fast
Ethernet
Media
First Junos OS
Support
40 GB hard disk
1 GB
CompactFlash card
9.0
Switch Control
Board
–
54 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 15: Routing Engine Specifications (continued)
Routing
Engine Processor Memory
Connection to PFEs Disk
RE-A-1000-2048 1.0-GHz
Pentium
2048 MB Gigabit
Ethernet
RE-A-2000-4096 2.0-GHz
Pentium
RE-S-1300-2048 1.3-GHz
Pentium
RE-S-2000-4096 2.0-GHz
Pentium
RE-C1800
RE-C2600
1.8-GHz
1.8 Ghz
2.6-GHz
4096 MB
2048 MB
4096 MB
8 GB
16 GB
16 GB
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
RE-A-1800x2 1800-MHz 8 GB or 16
GB
Gigabit
Ethernet
Media
First Junos OS
Support
Switch Control
Board
40 GB hard disk
1 GB
CompactFlash card
8.1
40 GB hard disk
1 GB
CompactFlash card
8.1
–
–
40 GB hard disk
1 GB
CompactFlash card
8.2
40 GB hard disk
1 GB
CompactFlash card
8.2
SSD
SCB, SCBE
SCB, SCBE
4 GB
CompactFlash card
T1600 router in a routing matrix:
9.6R2
CB-T for a standalone router.
Standalone
T640 or T1600 router:11.2
CB-LCC for a router in a routing matrix.
SSD
SSD
4 GB
CompactFlash card
32-bit Junos OS on a standalone
T1600 router:
11.4R2 32-bit
Junos OS on a
T1600 router in a routing matrix:
11.4R2
CB-T for a standalone router.
CB-LCC for a router in a routing matrix.
64-bit Junos OS on a standalone
T1600 router:
11.4R2 64-bit
Junos OS on a
T1600 router in a routing matrix:
11.4R2
4 GB
CompactFlash card
TX Matrix Plus router: 9.6R2
–
32 GB SSD 4 GB
CompactFlash card
10.4
–
Copyright © 2019, Juniper Networks, Inc.
55
T1600 Core Router Hardware Guide
Table 15: Routing Engine Specifications (continued)
Routing
Engine Processor Memory
Connection to PFEs Disk
RE-S-1800x2 1800-MHz 8 GB or 16
GB
Gigabit
Ethernet
RE-S-1800x4 1800-MHz 8GB or 16
GB
Gigabit
Ethernet
RE-S-MX104 1.8-GHz
RE-B-1800x1-4G 1.73-GHz
RE-MX2000-1800x4 1.8- GHz
RE-S-1800X4-32G-S 1.8- Ghz
REMX2K-1800-32G-S 1.8- Ghz
RE-S-X6-64G,
RE-S-X6-64G-LT
2 Ghz
REMX2K-X8-64G 2.3 Ghz
REMX2K-X8-64G-LT 2.3 Ghz
4 GB
4 GB
16 GB
32 GB
32 GB
64 GB
64 GB
64 GB
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Media
First Junos OS
Support
Switch Control
Board
32 GB SSD 4 GB
CompactFlash card
10.4
32 GB SSD 4 GB
CompactFlash card
10.4
– 8 GB NAND
Flash
13.2
64 GB SSD 4 GB
CompactFlash card
12.1R2, 11.4R4, and 12.2R1
32 GB SSD 4 GB Fixed
Internal
CompactFlash card
12.3R2
SCB, SCBE
SCB, SCBE,
SCBE2
–
–
SCB, SCBE
32 GB SSD 4 GB Fixed
Internal
CompactFlash card
•
•
12.3R4
13.2R1
32 GB SSD 4GB Fixed
Internal
CompactFlash card
•
•
12.3R4
13.2R1
15.1F4, 16.1
Two 50-GB
SSDs
-
Two
100-GB
SSDs
Two
100-GB
SSDs
-
15.1F5-S1, 16.1R2, and 16.2R1
17.2R1
SCB, SCBE
SCBE2
–
SCBE2
–
–
REMX2008-X8-64G 2.3 Ghz
RE-S-1600x8 1.6 Ghz
REMX2008-X8-64G-LT 2.1 Ghz
64 GB
64 GB
64 GB
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Two 50-GB
SSDs
–
Two 50-GB
SSDs
–
Two
100-GB
SSDs
-
15.1F7
17.3R1
17.2R1
–
–
-
56 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 15: Routing Engine Specifications (continued)
Routing
Engine Processor Memory
Connection to PFEs Disk
REMX2008-X8-128G 2.3 Ghz 128 GB Gigabit
Ethernet
RE-S-X6-128G 2.1 Ghz
REMX2K-X8-128G 2.1 Ghz
JNP10003-RE1 1.6-GHz
JNP10003-RE1-LT 1.6-GHz
128 GB
128 GB
64 GB
64 GB
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Two
200-GB
SSDs
Two
200-GB
SSDs
Two
200-GB
SSDs
Two 100
GB SSDs
Two 100
GB SSDs
JNP10K-RE0 2.5 GhZ
JNP10K-RE1 2.3 GhZ
JNP10K-RE1-LT 2.3 GhZ
JNP10K-RE1-128 2.3 GhZ
32 GB
64 GB
64 GB
128 GB
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
-
-
-
-
Two 50 GB
SSDs
-
Two 200
GB SSDs
Two 200
GB SSDs
-
Two 200
GB SSDs
-
Media
-
First Junos OS
Support
Switch Control
Board
18.2R1
-
18.1R1
18.1R1
17.3R1
18.1R1
17.2R1
18.2R1
18.3R1
18.3R1
-
-
-
-
-
-
-
-
NOTE: Use shielded CAT5e cable for connecting the AUX , CONSOLE , and
MGMT ports in RE-S-X6-64G, REMX2K-X8-64G, and REMX2008-X8-64G
Routing Engines.
Table 16: End-of-Life Routing Engine Specifications
Routing
Engine Processor Memory
Connection to PFEs Disk
RE-333-256 333-MHz
Pentium II
256 MB Fast
Ethernet
RE-333-768 333-MHz
Pentium II
768 MB Fast
Ethernet
Media
First Junos OS
Support
6.4 GB hard disk
80 MB
CompactFlash card
3.4
6.4 GB hard disk
80 MB
CompactFlash card
3.4
EOL Details
PSN-2003-01-063
PSN-2003-01-063
Copyright © 2019, Juniper Networks, Inc.
57
T1600 Core Router Hardware Guide
Table 16: End-of-Life Routing Engine Specifications (continued)
Routing
Engine Processor Memory
Connection to PFEs Disk Media
RE-600-512 600-MHz
Pentium III
512 MB Fast
Ethernet
RE-600-2048 600-MHz
Pentium III
2048 MB
RE-850-1536 850-MHz
Pentium III
1536 MB
RE-M40 200-MHz
Pentium
256 MB
RE-M40-333-768 333-MHz
Pentium II
768 MB
Fast
Ethernet
Fast
Ethernet
Fast
Ethernet
Fast
Ethernet
First Junos OS
Support
30 GB hard disk
256 MB
CompactFlash card
5.4
40 GB hard disk
1 GB
CompactFlash card
5.3
40 GB hard disk
1 GB
CompactFlash card
7.2
6.4 GB hard disk
80 MB
CompactFlash card
3.2
10 GB hard disk
80 MB
CompactFlash card
4.2
EOL Details
PSN-2004-07-019
PSN-2008-02-018
PSN-2011-04-226
FA-HW-0101-001
PSN-2003-01-063
RE-M40-600-2048 600-MHz
Pentium III
2048 MB
RE-1600-2048 1.6-GHz
Pentium M
2048 MB
Fast
Ethernet
Gigabit
Ethernet
30 GB hard disk
128 MB
CompactFlash card
5.4
40 GB hard disk
1 GB
CompactFlash card
6.2
PSN-2004-11-020
PSN-2008-02-019
NOTE: The memory in
indicates the amount of total memory. To determine the amount of available memory, issue the show chassis routing-engine CLI command.
On routers that accept two Routing Engines, you cannot mix Routing Engine types except for a brief period (one minute or so) during an upgrade or downgrade to two Routing
Engines of the same type.
Related
Documentation
•
Supported Routing Engines by Router on page 59
58 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Supported Routing Engines by Router
The following tables list the Routing Engines that each router supports, the first supported release for the Routing Engine in the specified router, the management Ethernet interface, and the internal Ethernet interfaces for each Routing Engine.
•
M7i Routing Engines on page 59
•
M10i Routing Engines on page 60
•
M40e Routing Engines on page 60
•
M120 Routing Engines on page 61
•
M320 Routing Engines on page 61
•
MX5, MX10, MX40, and MX80 Routing Engine on page 62
•
MX104 Routing Engines on page 62
•
MX240 Routing Engines on page 62
•
MX480 Routing Engines on page 63
•
MX960 Routing Engines on page 64
•
MX2008 Routing Engines on page 65
•
MX2010 Routing Engines on page 66
•
MX2020 Supported Routing Engines on page 66
•
MX10003 Routing Engines on page 67
•
MX10008 Routing Engines on page 67
•
PTX1000 Routing Engines on page 68
•
PTX3000 Routing Engines on page 68
•
PTX5000 Routing Engines on page 69
•
PTX10008 and PTX10016 Routing Engines on page 70
•
T320 Routing Engines on page 70
•
T640 Routing Engines on page 70
•
T1600 Routing Engines on page 71
•
T4000 Routing Engines on page 72
•
TX Matrix Routing Engines on page 73
•
TX Matrix Plus Routing Engines on page 73
•
TX Matrix Plus (with 3D SIBs) Routing Engines on page 74
M7i Routing Engines
lists the Routing Engines supported by the M7i router. The M7i router supports 32-bit Junos OS only.
Copyright © 2019, Juniper Networks, Inc.
59
T1600 Core Router Hardware Guide
Table 17: M7i Routing Engines
Model Number
RE-400-768 (EOL details:
TSB16445 )
RE-850-1536 (EOL details:
TSB15553 )
RE-B-1800X1-4G
Name in CLI
Output
RE-5.0
RE-850
RE-B-1800x1
First Supported 32-bit
Junos OS Release
Management
Ethernet Interface
Internal Ethernet
Interface
9.0
fxp0 fxp1
7.2
fxp0 fxp1
11.4R4
12.1R2
fxp0 em0
M10i Routing Engines
lists the Routing Engines supported by the M10i router. The M10i router supports 32-bit Junos OS only.
Table 18: M10i Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
Management
Ethernet Interface
Internal Ethernet
Interface
RE-400-768 (EOL details:
TSB16445 )
RE-5.0
9.0
fxp0
RE-850-1536 (EOL details:
TSB15553 )
RE-850 7.2
fxp0 fxp1 fxp2 fxp1 fxp2
RE-B-1800X1-4G RE-B-1800x1 11.4R4
12.1R2
fxp0 em0
M40e Routing Engines
lists the Routing Engines supported by the M40e router.
Table 19: M40e Routing Engines
Model Number Name in CLI Output
First Supported
Junos OS Release
Management
Ethernet Interface
Internal Ethernet
Interface
RE-600-2048 (EOL details:
TSB14373 )
RE-3.0
or RE-3.0
(RE-600)
5.3
fxp0
RE-A-1000-2048 RE-A-1000 8.1
fxp0 fxp1 fxp2 fxp1 fxp2
60 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
M120 Routing Engines
lists the Routing Engines supported by the M120 router.
Table 20: M120 Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First
Supported
64-bit Junos
OS Release
Management
Ethernet
Interface
Internal Ethernet
Interface
RE-A-1000-2048 RE-A-1000 8.0R2
– fxp0
RE-A-2000-4096
RE-A-1800X2-8G
RE-A-1800X2-16G
RE-A-1800X4-16G
RE-A-2000
RE-A-1800x2
RE-A-1800x2
RE-A-1800x4
8.0R2
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
–
10.4
10.4
10.4
fxp0 fxp0 fxp0 fxp0 fxp1 fxp2 em0 em1 fxp1 fxp2 em0 bcm0 fxp1 fxp2
M320 Routing Engines
lists the Routing Engines supported by the M320 router.
Table 21: M320 Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First
Supported
64-bit Junos
OS Release
Management
Ethernet
Interface
Internal Ethernet
Interface
RE-1600-2048 (EOL details: TSB14374 )
RE-4.0
6.2
– fxp0 fxp1 fxp2
RE-A-2000-4096
RE-A-1800X2-8G
RE-A-2000
RE-A-1800x2
8.1
•
•
11.4R5
12.1R3
–
10.4
fxp0 fxp0 em0 bcm0 em0 bcm0
Copyright © 2019, Juniper Networks, Inc.
61
T1600 Core Router Hardware Guide
Table 21: M320 Routing Engines (continued)
Model Number
RE-A-1800X2-16G
Name in CLI
Output
RE-A-1800x2
First Supported
32-bit Junos OS
Release
•
•
11.4R5
12.1R3
First
Supported
64-bit Junos
OS Release
10.4
10.4
Management
Ethernet
Interface
Internal Ethernet
Interface fxp0 fxp0 em0 bcm0 em0 em1
RE-A-1800X4-8G RE-A-1800X4 •
•
•
11.4R5
12.1R3
12.2
MX5, MX10, MX40, and MX80 Routing Engine
lists the Routing Engines supported by the MX5, MX10, MX40, and
MX80 routers.
Table 22: MX5, MX10, MX40, and MX80 Routing Engine
Model
Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface Internal Ethernet Interface
Built-in Routing
Engine
Routing Engine
RE-MX80
12.3
fxp0 em0 em1
NOTE: em1 is used to communicate with the
MS-MIC when it is inserted.
MX104 Routing Engines
lists the Routing Engines supported by MX104 routers.
Table 23: MX104 Routing Engines
Model
Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
Internal Ethernet
Interface
RE-S-MX104 Routing Engine 13.2
– fxp0 fxp1 fxp2
MX240 Routing Engines
lists the Routing Engines supported by MX240 routers.
62 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 24: MX240 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
RE-S-1300-2048
(EOL details:
TSB16556
RE-S-1300 9.0
– fxp0
9.0
– fxp0 RE-S-2000-4096
(EOL details:
TSB16735
RE-S-2000
RE-S-1800X2-8G
(EOL details:
TSB16556
RE-S-1800x2
RE-S-1800x2-16G
(EOL details:
TSB16556
RE-S-1800x2
RE-S-1800X4-8G RE-S-1800X4
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
10.4
10.4
10.4
fxp0 fxp0 fxp0
RE-S-1800X4-16G RE-S-1800x4
RE-S-1800X4-32G-S RE-S-1800X4
•
•
11.4R5
12.1R3
•
•
12.3R4
13.2R1
10.4
•
•
12.3R4
13.2R1
fxp0 fxp0
RE-S-X6-64G RE-S-2X00x6 – 15.1F4
16.1R1
17.2R1
fxp0
RE-S-X6-64G-LT RE-S-2X00x6 -LT – fxp0 ixlv0, igb0 em0
RE-S-X6-128G RE-S-2X00x6-128 – 18.1R1
fxp0 ixlv0, igb0 em0
MX480 Routing Engines
lists the Routing Engines supported by MX480 routers.
Internal Ethernet
Interface fxp1 fxp2 fxp1 fxp2 em0 em1 em0 em1 em0 em1 em0 em1 em0, em1 ixlv0, igb0
Copyright © 2019, Juniper Networks, Inc.
63
T1600 Core Router Hardware Guide
Table 25: MX480 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
RE-S-1300-2048
(EOL details:
TSB16556
RE-S-1300 8.4
– fxp0
8.4
– fxp0 RE-S-2000-4096
(EOL details:
TSB16735
RE-S-2000
RE-S-1800X2-8G
(EOL details:
TSB16556
RE-S-1800x2
RE-S-1800X2-16G
(EOL details:
TSB16556
RE-S-1800x2
RE-S-1800X4-8G RE-S-1800X4
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
10.4
10.4
10.4
fxp0 fxp0 fxp0
RE-S-1800X4-16G RE-S-1800x4
RE-S-1800X4-32G-S RE-S-1800X4
RE-S-X6-64G RE-S-2X00x6
•
•
11.4R5
12.1R3
•
•
12.3R4
13.2R1
–
10.4
•
•
12.3R4
13.2R1
15.1F4
16.1R1
17.2R1
fxp0 fxp0 fxp0
Internal Ethernet
Interface fxp1 fxp2 fxp1 fxp2 em0 em1 em0 em1 em0 em1 em0 em1 em0 em1 ixlv0, igb0
RE-S-X6-64G-LT RE-S-2X00x6 -LT –
RE-S-X6-128G RE-S-2X00x6-128 – 18.1R1
fxp0 fxp0 ixlv0, igb0 em0 ixlv0, igb0 em0
MX960 Routing Engines
lists the Routing Engines supported by MX960 routers.
64 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 26: MX960 Supported Routing Engines
Model Number
RE-S-1300-2048 (EOL details: TSB16556
RE-S-2000-4096 (EOL details: TSB16735
RE-S-1800X2-8G (EOL details: TSB16556
RE-S-1800X2-16G (EOL details: TSB16556
RE-S-1800X4-8G
RE-S-1800X4-16G
RE-S-1800X4-32G-S
RE-S-X6-64G
RE-S-X6-64G (For
MX960-VC)
RE-S-X6-64G-LT
RE-S-X6-128G
Name in CLI
Output
RE-S-1300
RE-S-2000
RE-S-1800x2
RE-S-1800x2
RE-S-1800x4
RE-S-1800x4
RE-S-1800x4
RE-S-2X00x6
RE-S-2X00x6
First Supported
32-bit Junos
OS Release
First
Supported
64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
8.2
– fxp0
8.2
– fxp0 fxp1 fxp2 fxp1 fxp2
•
•
11.4R5
12.1R3
10.4
fxp0
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
10.4
10.4
fxp0 fxp0 em0 em1 em0 em1 em0 em1
•
•
11.4R5
12.1R3
10.4
fxp0
•
•
12.3R4
13.2R1
–
•
•
12.3R4
13.2R1
fxp0 fxp0 em0 em1 em0 em1 ixlv0, igb0 15.1F4
16.1R1
– 17.1R2
fxp0 ixlv0, igb0
RE-S-2X00x6 -LT –
RE-S-2X00x6-128 –
17.2R1
18.1R1
fxp0 fxp0 ixlv0, igb0 em0 ixlv0, igb0 em0
MX2008 Routing Engines
lists the Routing Engines supported by MX2008 routers.
Copyright © 2019, Juniper Networks, Inc.
65
T1600 Core Router Hardware Guide
Table 27: MX2008 Supported Routing Engines
Model Number
REMX2008-X8-64G
Name in CLI
Output
First Supported 64-bit Junos
OS Release
RE-MX2008-X8-64G 15.1F7
Management
Ethernet
Interface fxp0
REMX2008-X8-64G-LT
REMX2008-X8-128G
REMX2008-X8-64G-LT 17.2R1
RE-MX2008-X8-128G 18.2R1
fxp0 fxp0
Internal
Ethernet
Interface ixlv0 ixlv1 ixlv0 ixlv1 ixlv0 ixlv1
MX2010 Routing Engines
lists the Routing Engines supported by MX2010 routers.
Table 28: MX2010 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported 64-bit Junos
OS Release
Management
Ethernet
Interface
Internal Ethernet
Interface
RE-MX2000-1800X4 RE-S-1800x4 12.3R2
fxp0
REMX2K-1800-32G-S
REMX2K-X8-64G
REMX2K-X8-64G-LT
REMX2K-X8-128G
RE-S-1800x4
RE-S-2X00x8
RE-S-2X00x8
•
•
12.3R4
13.2R1
•
•
•
15.1F5-S1
16.1R2
16.2R1
17.2R1
RE-MX200X8-128G 18.1R1
fxp0 fxp0 fxp0 fxp0 ixlv0 ixlv1 em0 ixlv0 ixlv1 em0 ixlv0 ixlv1 em0 em1 em0 em1
MX2020 Supported Routing Engines
lists the Routing Engines supported by MX2020 routers.
66 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 29: MX2020 Supported Routing Engines
Model Number
RE-MX2000-1800X4
REMX2K-1800-32G-S
REMX2K-X8-64G
REMX2K-X8-64G-LT
REMX2K-X8-128G
Name in CLI
Output
RE-S-1800x4
RE-S-1800x4
RE-S-2X00x8
RE-S-2X00x8
First Supported 64-bit Junos
OS Release
Management
Ethernet
Interface
12.3R2
fxp0
•
•
12.3R4
13.2R1
•
•
•
15.1F5-S1
16.1R2
16.2R1
17.2R1
RE-MX200X8-128G 18.1R1
fxp0 fxp0 fxp0 fxp0
Internal
Ethernet
Interface ixlv0 ixlv1 em0 ixlv0 ixlv1 em0 em0 em1 em0 em1 ixlv0 ixlv1 em0
MX10003 Routing Engines
lists the Routing Engines supported by MX10003 routers.
Table 30: MX10003 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported 64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
JNP10003-RE1 RE-S-2X00x6 17.3R1
fxp0
JNP10003-RE1-LT RE-S-1600x8 18.1R1
fxp0 em3 em4 em3 em4
MX10008 Routing Engines
lists the Routing Engines supported on the MX10008 router.
Copyright © 2019, Juniper Networks, Inc.
67
T1600 Core Router Hardware Guide
Table 31: MX10008 Routing Engines
Model Number Name in CLI Output
First Supported
Junos OS Release
JNP10K-RE1 RE X10 18.2R1
JNP10K-RE1-LT
JNP10K-RE1-128
RE X10 LT
RE X10 128G
18.3R1
18.3R1
Management
Ethernet Interface em0
Internal Ethernet
Interface em0 em0 bme0 bme1 bme0 bme1 bme0 bme1
PTX1000 Routing Engines
lists the Routing Engine supported on the PTX1000.
NOTE: The PTX1000 supports 64-bit Junos OS only.
Table 32: PTX1000 Routing Engines
Model Number
Name in CLI
Output
Built-in Routing
Engine
RE-PTX1000
First Supported Junos OS
Release
Management
Ethernet Interface
•
•
16.1X65-D30
17.2R1
em0
Internal Ethernet
Interface bme0 em1
PTX3000 Routing Engines
lists the Routing Engines supported on the PTX3000.
Table 33: PTX3000 Routing Engines
Model Number
Name in CLI
Output
RE-DUO-C2600-16G RE-DUO-2600
NOTE: The PTX3000 supports 64-bit Junos OS only.
First Supported Junos OS
Release
13.2R2
Management
Ethernet Interface em0
Internal Ethernet
Interface ixgbe0 ixgbe1
68 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 33: PTX3000 Routing Engines (continued)
Model Number
RCB-PTX-X6-32G
Name in CLI
Output
RE-PTX-2X00x6
First Supported Junos OS
Release
Management
Ethernet Interface
Internal Ethernet
Interface
16.1R4
17.1R1
This Routing Engine does not support Junos OS Release 16.2.
em0 ixlv0 ixlv1
PTX5000 Routing Engines
lists the Routing Engines supported on the PTX5000.
NOTE:
• PTX5000 supports 64-bit Junos OS only.
• The PTX5000 router supports two midplanes. The midplane identified as
Midplane-8S in the CLI output is supported in Junos OS releases, 12.1X48,
12.3, and 13.2. The enhanced midplane, identified as Midplane-8SeP is supported from Junos OS release 14.1 onwards.
The RE-DUO-2600 routing engine with Junos OS 13.2 or earlier is not supported on the PTX5000BASE2 midplane.
Table 34: PTX5000 Routing Engines
Model Number Name in CLI Output
RE-DUO-C2600-16G RE-DUO-2600
First Supported Junos OS
Release
RE-PTX-X8-64G RE-PTX-2X00x8
Management
Ethernet
Interface
12.1X48
12.3
13.2
NOTE: The PTX5000 does not support Junos OS Releases 12.1,
12.2, or 13.1.
em0
15.1F4
16.1R1
em0
RE-PTX-X8-128G RE-PTX-2X00x8-128G 18.1R1
em0 ixlv0 ixlv1 em1 ixlv0 ixlv1 em1
Internal Ethernet
Interface ixgbe0 ixgbe1
Copyright © 2019, Juniper Networks, Inc.
69
T1600 Core Router Hardware Guide
PTX10008 and PTX10016 Routing Engines
lists the Routing Engines supported on the PTX10008 and PTX10016 routers.
Table 35: PTX10008 and PTX10016 Routing Engines
Model Number Name in CLI Output
First Supported
Junos OS Release
Management
Ethernet Interface
Internal Ethernet
Interface
JNP10K-RE0 RE-PTX-2X00x4 17.2R1
em0, em1
JNP10K-RE1
JNP10K-RE1-LT
RE X10
RE X10 LT
18.2R1
18.3R1
em0 em0 bme0 bme1 bme0 bme1 bme0 bme1
JNP10K-RE1-128 RE X10 128G 18.3R1
em0 bme0 bme1
T320 Routing Engines
lists the Routing Engines supported by the T320 router.
Table 36: T320 Routing Engines
Model Number Name in CLI Output
First Supported
32-bit Junos OS
Release
Management
Ethernet Interface
Internal Ethernet
Interface
RE-600-2048 (EOL details:
TSB14373 )
RE-3.0
or RE-3.0
(RE-600)
5.3
fxp0 fxp1 fxp2
RE-1600-2048 (EOL details:
TSB14374
RE-4.0
6.2
fxp0
RE-A-2000-4096 RE-A-2000 8.1
fxp0 fxp1 fxp2 fxp1 fxp2
The T320 router supports the CB-T control board.
T640 Routing Engines
lists the Routing Engines supported by the T640 router.
70 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 37: T640 Routing Engines
Model Number
Name in CLI
Output
First Supported 32-bit
Junos OS Release
First Supported 64-bit
Junos OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-600-2048 (EOL details: TSB14373 )
RE-3.0
or
RE-3.0
(RE-600)
RE-1600-2048 (EOL details: TSB14374
RE-4.0
5.3
6.2
–
– fxp0 fxp0 fxp1 fxp2
RE-A-2000-4096 RE-A-2000 8.1
– fxp0 fxp1 fxp2 em0 bcm0
RE-DUO-C1800-8G RE-DUO-1800 32-bit Junos OS on a standalone T640 router:
11.2
32-bit Junos OS on a
T640 router in a routing matrix: 11.4R9
64-bit Junos OS on a standalone T640 router:
11.3
em0
64-bit Junos OS on a
T640 router in a routing matrix: 11.4R9
RE-DUO-C1800-16G RE-DUO-1800 32-bit Junos OS on a standalone T640 router:
11.4R2
64-bit Junos OS on a standalone T640 router:
11.4R2
em0
32-bit Junos OS on a
T640 router in a routing matrix: 11.4R9
64-bit Junos OS on a
T640 router in a routing matrix: 11.4R9
bcm0 em1 bcm0 em1
The T640 standalone router supports CB-T control board and CB-LCC in a T640 routing matrix.
T1600 Routing Engines
lists the Routing Engines supported by the T1600 router.
NOTE: (Two RE-DUO-C1800-8G or two RE-DUO-C1800-16G are required to connect to a Routing Matrix)
Table 38: T1600 Routing Engines
Model Number
Name in CLI
Output
RE-600-2048 (EOL details: TSB14373 )
RE-3.0
or
RE-3.0
(RE-600)
First Supported 32-bit
Junos OS Release
8.5
First Supported
64-bit Junos OS
Release
–
Management
Ethernet
Interface
Internal
Ethernet
Interface fxp0 fxp1 fxp2
Copyright © 2019, Juniper Networks, Inc.
71
T1600 Core Router Hardware Guide
Table 38: T1600 Routing Engines (continued)
Model Number
RE-1600-2048 (EOL details: TSB14374
RE-A-2000-4096
Name in CLI
Output
RE-4.0
(RE-1600)
RE-A-2000
First Supported 32-bit
Junos OS Release
8.5
8.5
First Supported
64-bit Junos OS
Release
–
–
RE-DUO-C1800-8G RE-TXP-LCC or
RE-DUO-1800
32-bit Junos OS on a T1600 router in a routing matrix: 9.6
NOTE: Junos OS Releases
9.6 through 10.4 support
RE-DUO-C1800-8G only during upgrade to a line-card chassis (LCC) in a routing matrix.
64-bit Junos OS on a
T1600 router in a routing matrix: 9.6
64-bit Junos OS on a standalone T1600 router: 11.1
32-bit Junos OS on a standalone T1600 router: 11.1
em0
RE-DUO-C1800-16G RE-DUO-1800 32-bit Junos OS on a standalone T1600 router:
11.4R2
32-bit Junos OS on a T1600 router in a routing matrix:
11.4R2
64-bit Junos OS on a standalone T1600 router: 11.4R2
64-bit Junos OS on a
T1600 router in a routing matrix: 11.4R2
em0
Management
Ethernet
Interface
Internal
Ethernet
Interface fxp0 fxp0 fxp1 fxp2 em0 bcm0 bcm0 em1 bcm0 em1
T4000 Routing Engines
lists the Routing Engines supported by the T4000 router.
NOTE: The T4000 router supports 64-bit Junos OS only.
Table 39: T4000 Routing Engines
Model Number
Name in CLI
Output
RE-DUO-C1800-8G RE-DUO-1800
RE-DUO-C1800-16G RE-DUO-1800
First Supported 64-bit Junos OS
Release
Management
Ethernet
Interface
Standalone T4000 router: 12.1
T4000 router in a routing matrix: 13.1
em0
Standalone T4000 router: 12.1R2
T4000 router in a routing matrix: 13.1
em0
Internal Ethernet
Interface bcm0 em1 bcm0 em1
72 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
The T4000 router supports the CB-LCC control board.
TX Matrix Routing Engines
lists the Routing Engines supported by the TX Matrix router.
Table 40: TX Matrix Routing Engines
Model Number
Name in CLI
Output
First
Supported
32-bit Junos
OS Release
First
Supported
64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-600-2048 (EOL details: TSB14373 )
RE-3.0
or RE-3.0
(RE-600)
7.0
– fxp0
RE-1600-2048 (EOL details: TSB14374
RE-4.0 (RE-1600) 7.0
– fxp0 fxp1 fxp2 fxp1 fxp2
RE-A-2000-4096
RE-DUO-C1800-8G
RE-DUO-C1800-16G
RE-A-2000
RE-DUO-1800
RE-DUO-1800
8.5
11.4R9
11.4R9
–
11.4R9
11.4R9
fxp0 em0 em0 em0 bcm0 bcm0 em1 bcm0 em1
The TXP router supports two control boards, CB-TX and CB-LCC. The CB-LCC is required for both RE-DUO-C1800-8G and RE-DUO-C1800-16G Routing Engines.
TX Matrix Plus Routing Engines
lists the Routing Engines supported by the TX Matrix Plus router.
Table 41: TX Matrix Plus Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-DUO-C2600-16G RE-TXP-SFC or
RE-DUO-2600
32-bit Junos OS: 9.6
64-bit Junos OS: 11.4
em0 ixgbe0 ixgbe1
The TX Matrix Plus router supports the CB-TXP control board.
Copyright © 2019, Juniper Networks, Inc.
73
T1600 Core Router Hardware Guide
TX Matrix Plus (with 3D SIBs) Routing Engines
lists the Routing Engines supported by the TX Matrix Plus router with 3D SIBs.
Table 42: Routing Engines on TX Matrix Plus with 3D SIBs
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-DUO-C2600-16G RE-TXP-SFC or
RE-DUO-2600
64-bit Junos OS: 11.4
em0 ixgbe0 ixgbe1
Related
Documentation
•
Routing Engine Specifications on page 54
• Understanding Internal Ethernet Interfaces
• Understanding Management Ethernet Interfaces
T1600 Control Boards Description
The T1600 chassis supports up to two control boards. The Routing Engine requires an adjacent control board to provide control and monitoring functions for the T1600 Core
Router. These functions include determining Routing Engine mastership, controlling power and reset for the other T1600 router components, monitoring and controlling fan speed, and monitoring system status.
You can install up to two control boards in the chassis. Control boards install into the upper rear of the chassis in the slots labeled CB0 and CB1 (referred to as CB-0 and CB-1 , top to bottom). If two control boards are installed, one functions as the master and the other as its backup. If the master fails or is removed, the backup restarts and becomes the master.
Each control board requires a Routing Engine to be installed in the adjacent slot.
CB0 installs above RE0 , and CB1 installs below RE1 . Control boards cannot function if a Routing
Engine is not present in the adjacent slot.
If the host system is redundant, the backup control board is hot-removable and hot-insertable, but the master control board is hot-pluggable. A control board that is not redundant is hot-pluggable.
The T1600 router supports the control boards listed in
74 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 43: T1600 Supported Control Boards
Name Model Number CLI Output
First Supported
Junos OS
Release
T Series control board
(T-CB)
CB-T
NOTE: CB-T-L is not supported.
T-series Control Board
NOTE: The control board shown as CB-T in the CLI output is the T640 standard control board
(model number CB-L-T), which is not supported for
T1600 routers, and not the T-series control board
(model number CB-T).
8.5
Line-card chassis control board
(LCC-CB)
NOTE: The LCC-CB is required for connection to a TX
Matrix Plus router.
CB-LCC
The LCC-CB is required for both
RE-DUO-C1800-8G and
RE-DUO-C1800-16G
Routing Engines.
LCC Control Board 9.6R2 for routers in a routing matrix
11.1 for standalone
T1600 routers.
Related
Documentation
•
T1600 Host Subsystem Description on page 43
•
T1600 T Series Control Boards (T-CBs) Description on page 75
•
T1600 Line-Card Chassis Control Board (LCC-CB) Description on page 77
•
Maintaining the T1600 Host Subsystem on page 520
•
Maintaining the T1600 Control Boards on page 511
•
Troubleshooting the T1600 Control Boards on page 548
•
Troubleshooting the T1600 Host Subsystems on page 547
T1600 T Series Control Boards (T-CBs) Description
Each T-CB (see
Figure 27 on page 76 ) consists of the following components:
• 100-MB Ethernet switch for intermodule communication.
• PCI bus to the Routing Engines.
• Switch processor mezzanine board (SPMB).
Copyright © 2019, Juniper Networks, Inc.
75
T1600 Core Router Hardware Guide
• Three LEDs, labeled MASTER , FAIL , and OK , are located on the T-CB faceplate, and indicate its status.
• The T-CB online/offline button, located on the faceplate. This button is nonfunctional.
• Two configuration switches, located on the faceplate: the M/S and CHASSIS ID configuration switches must always be set to S and 0 for a standalone T1600 router.
• Two RJ-45 ports labeled AUX and CIP on the T-CB faceplate, which are not used for the T1600 router.
Figure 27: T-CB
Related
Documentation
•
T1600 Host Subsystem Description on page 43
•
T1600 Control Boards Description on page 74
•
•
Maintaining the T1600 Host Subsystem on page 520
•
Maintaining the T1600 Control Boards on page 511
•
Troubleshooting the T1600 Control Boards on page 548
•
Troubleshooting the T1600 Host Subsystems on page 547
T1600 T-CB LEDs
describes the functions of the T-CB LEDs.
Table 44: T-CB LEDs
Label Color State Description
MASTER Blue
–
On steadily T-CB is functioning as the master.
Off T-CB is functioning as the backup.
76 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 44: T-CB LEDs (continued)
Label Color State
FAIL
OK
Yellow
–
Green
Description
On steadily T-CB has failed.
Off No faults have been detected on the T-CB.
On steadily T-CB is online and is functioning normally.
Blinking T-CB is powering up, but not online.
– Off T-CB is offline.
Related
Documentation
•
T1600 Host Subsystem Description on page 43
•
T1600 Control Boards Description on page 74
•
T1600 T Series Control Boards (T-CBs) Description on page 75
•
Maintaining the T1600 Host Subsystem on page 520
•
Maintaining the T1600 Control Boards on page 511
•
Troubleshooting the T1600 Control Boards on page 548
•
Troubleshooting the T1600 Host Subsystems on page 547
T1600 Line-Card Chassis Control Board (LCC-CB) Description
The LCC-CBs (see
Figure 28 on page 77 ) must be installed before you can connect a
T1600 router to a TX Matrix Plus Router.
NOTE: The LCC-CB is required for both RE-DUO-C1800-8G and
RE-DUO-C1800-16G Routing Engines.
Each LCC-CB consists of the following components:
• 100-MB Ethernet switch for intermodule communication.
• PCI bus to the Routing Engines.
• Switch processor mezzanine board (SPMB).
Figure 28: LCC-CB
Copyright © 2019, Juniper Networks, Inc.
77
T1600 Core Router Hardware Guide
The following components are located on the LCC-CB faceplate:
• Two configuration switches:
• The M/S configuration switch must be set to M before you connect the LCC-CB to a TX Matrix Plus Router. The switch must be set to S for a standalone T1600 router.
• The CHASSIS ID configuration switch is set to 0 through 4 to indicate the LCC number for the T1600 router. The CHASSIS ID configuration switch must always be set to 0 for a standalone T1600 router.
• Three LEDs labeled MASTER , FAIL , and OK indicate its status.
• The online/offline button.
• Six RJ-45 ports labeled SFC0 through SFC5 .
SFC0 connects to the TX Matrix Plus router.
Two LEDs labeled LINK and ACT indicate the status of SFC0 .
SFC1 through SFC5 are not currently supported.
• One JCS port, which is not used. The LINK LED for this port is also not currently supported.
Related
Documentation
•
T1600 Host Subsystem Description on page 43
•
T1600 Control Boards Description on page 74
•
•
Maintaining the T1600 Host Subsystem on page 520
•
Maintaining the T1600 Control Boards on page 511
•
Troubleshooting the T1600 Control Boards on page 548
•
Troubleshooting the T1600 Host Subsystems on page 547
T1600 LCC-CB LEDs
Status LEDs and port LEDs are located on the faceplate of the LCC-CB (see
Figure 29: LCC-CB LEDs
Link
LED
Activity
LED
78 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
The LEDs located in the middle of the LCC-CB indicate its status.
describes the functions of the LCC-CB LEDs.
Table 45: LCC-CB LEDs
Label Color State Description
MASTER
FAIL
Blue
–
Yellow
–
On steadily LCC-CB is functioning as the master.
Off LCC-CB is functioning as the backup.
On steadily LCC-CB has failed.
Off No faults have been detected on the LCC-CB.
OK Green
–
On steadily LCC-CB is online and is functioning normally.
Blinking
Off
LCC-CB is powering up, but not online.
LCC-CB is offline.
The LEDs located next to each port indicate its status.
describes the functions of the LCC-CB port LEDs.
Table 46: LCC-CB LEDs
Label Color State Description
ACT Green
–
SFC0 LINK Green
Yellow
–
On steadily Traffic is passing through the port.
Off No traffic is passing through the port.
On steadily 1-Gbps connection
On steadily 10/100-Mbps connection
Off LCC-CB is not connected to the TX Matrix Plus SFC.
JCS LINK – – This port is not used.
Related
Documentation
•
T1600 Host Subsystem Description on page 43
•
T1600 Control Boards Description on page 74
•
T1600 Line-Card Chassis Control Board (LCC-CB) Description on page 77
•
Maintaining the T1600 Host Subsystem on page 520
•
Maintaining the T1600 Control Boards on page 511
•
Troubleshooting the T1600 Control Boards on page 548
•
Troubleshooting the T1600 Host Subsystems on page 547
Copyright © 2019, Juniper Networks, Inc.
79
T1600 Core Router Hardware Guide
80 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 6
Line Card Components and Descriptions
•
T1600 Flexible PIC Concentrator (FPC) Description on page 81
•
T1600 FPCs Supported on page 92
•
T1600 PIC Description on page 94
•
T1600 PICs Supported on page 95
•
T1600 End-of-Life PICs Supported on page 104
•
T1600 PIC Combination Limitations on page 105
•
T1600 PIC/FPC Compatibility on page 106
T1600 Flexible PIC Concentrator (FPC) Description
FPCs are hot-removable and hot-insertable.
•
•
•
T1600 FPC Components on page 82
•
T1600 FPC Terminology on page 82
•
Identifying the T1600 FPCs on page 83
T1600 FPC Function
FPCs house the PICs that connect the T1600 Core Router to network media. The main function of an FPC is to connect the PICs installed in it to the other T1600 router components. The Packet Forwarding Engine receives incoming packets from the PICs installed on the FPC and forwards them through the switch planes to the appropriate destination port. In a maximum configuration with eight Type 4 FPCs installed, the Packet
Forwarding Engines can forward up to 1600 million packets per second (Mpps) for all packet sizes. The T1600 Core Router provides up to 800 gigabits per second (Gbps), full duplex switching (1600 Gbps of any-to-any, nonblocking, half-duplex switching).
When you install an FPC into a functioning router, the Routing Engine downloads the
FPC software, the FPC runs its diagnostics, and the PICs housed on the FPC, are enabled.
Forwarding on other FPCs continues uninterrupted during this process.
Copyright © 2019, Juniper Networks, Inc.
81
T1600 Core Router Hardware Guide
T1600 FPC Slots
Up to eight FPCs install vertically in the front of the router. The FPC slots are numbered
FPC0 through FPC7 , left to right. If a slot is not occupied by an FPC, an FPC blank panel must be installed to shield the empty slot and to allow cooling air to circulate properly through the router.
T1600 FPC Components
Each FPC consists of the following components:
• FPC card carrier.
• One or two Packet Forwarding Engines, consisting of Layer 2/Layer 3 Packet Processing
ASICs, Switch Interface ASICs, T-series Internet Processor ASICs, and a Memory
Mezzanine Board (MMB) which includes the Queuing and Memory Interface ASICs.
• Each Type 1 FPC has one Packet Forwarding Engine
• Each Type 2 FPC has one Packet Forwarding Engine
• Each Type 3 FPC has two Packet Forwarding Engines
• Each T640-FPC4-ES has one Packet Forwarding Engine
• Each T640-FPC4-1P-ES has one Packet Forwarding Engine
• Each T1600-FPC4-ES has two Packet Forwarding Engines
• Processor Mezzanine Board (PMB), which includes a 300-MHz CPU, system controller,
256 MB of SDRAM, and two Fast Ethernet interfaces.
• Two LEDs, located on the craft interface above the FPC, that display the status of the
FPC.
• FPC online/offline button, located on the craft interface above the FPC.
T1600 FPC Terminology
Regardless of whether you are holding an FPC vertically or horizontally, this document uses the same terms for all four edges of the FPC (see
• Faceplate—Edge of the FPC that has slots into which you insert the PICs
• Connector edge—Edge opposite the faceplate; this edge has the connectors that attach to the midplane
• Top edge—Edge at the top of the FPC when it is vertical
• Bottom edge—Edge at the bottom of the FPC when it is vertical
82 Copyright © 2019, Juniper Networks, Inc.
Figure 30: FPC Edges
Chapter 6: Line Card Components and Descriptions
Identifying the T1600 FPCs
Check the label on the faceplate to identify the FPC. For FPCs without a label on the faceplate, check the location of a PIC's offline button and how the PIC is secured to the
FPC. See
.
Table 47: Identifying the FPCs Supported by the T1600 Router
FPC Label on the FPC Faceplate
Location of PIC Offline
Button
Method of Securing the PIC to the FPC
Enhanced FPC1 E FPC1
Enhanced II FPC1
Enhanced Scaling FPC1
E-II FPC1
T640-FPC1-ES
Slightly beneath the faceplate of the PIC
Two captive screws
Slightly beneath the faceplate of the PIC
Two captive screws
Slightly beneath the faceplate of the PIC
Two captive screws
FPC2
Enhanced FPC2
Enhanced II FPC2
Enhanced Scaling FPC2
None
E FPC2
E-II FPC2
T640-FPC2-ES
Inside an opening directly on the faceplate of each PIC
Two captive screws
Inside an opening directly on the faceplate of each PIC
Two captive screws
Inside an opening directly on the faceplate of each PIC
Two captive screws
Inside an opening directly on the faceplate of each PIC
Two captive screws
Copyright © 2019, Juniper Networks, Inc.
83
T1600 Core Router Hardware Guide
Table 47: Identifying the FPCs Supported by the T1600 Router (continued)
FPC Label on the FPC Faceplate
Location of PIC Offline
Button
FPC3 None
Enhanced FPC3
Enhanced II FPC3
Enhanced Scaling FPC3
E FPC3
E-II FPC3
T640-FPC3-ES
T640 Enhanced Scaling FPC4 FPC4
Method of Securing the PIC to the FPC
Inside an opening directly on the faceplate of each PIC
Plastic ejector handle at the top of the PIC faceplate; captive screw at the bottom of the PIC faceplate
Inside an opening directly on the faceplate of each PIC
Plastic ejector handle at the top of the PIC faceplate; captive screw at the bottom of the PIC faceplate
Inside an opening directly on the faceplate of each PIC
Plastic ejector handle at the top of the PIC faceplate; captive screw at the bottom of the PIC faceplate
Inside an opening directly on the faceplate of each PIC
Two plastic ejector handles at the top and bottom of the
PIC faceplate
Inside an opening directly on the faceplate of each PIC
Two plastic ejector handles at the top and bottom of the
PIC faceplate
T640 Enhanced Scaling
FPC4-1P
T1600 Enhanced Scaling
FPC4
T640-FPC4–1P-ES
T1600-FPC4
Inside an opening directly on the faceplate of each PIC
Two plastic ejector handles at the top and bottom of the
PIC faceplate
Inside an opening directly on the faceplate of each PIC
Two plastic ejector handles at the top and bottom of the
PIC faceplate
84 Copyright © 2019, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
The T1600 router supports the Enhanced Scaling FPC1, as shown in
Figure 31: Enhanced Scaling FPC1 Supported by the T1600 Router
Copyright © 2019, Juniper Networks, Inc.
85
T1600 Core Router Hardware Guide
The T1600 router supports the standard FPC2 and FPC3, as shown in
.
Figure 32: Standard FPC2 and FPC3 Supported by the T1600 Router
FPC2
FPC3
86 Copyright © 2019, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
The T1600 router supports the Enhanced II FPC1, FPC2, and FPC3, as shown in
Figure 33: Enhanced II FPC1, FPC2, and FPC3 Supported by the T1600 Router
Copyright © 2019, Juniper Networks, Inc.
87
T1600 Core Router Hardware Guide
The T1600 router supports the Enhanced Scaling FPC2, as shown in
.
Figure 34: T640 Enhanced Scaling FPC2 Supported by the T1600 Router
88 Copyright © 2019, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
The T1600 router supports the Enhanced Scaling FPC3, as shown in
Figure 35: T640 Enhanced Scaling FPC3 Supported by the T1600 Router
Copyright © 2019, Juniper Networks, Inc.
89
T1600 Core Router Hardware Guide
The T1600 router supports the T640 Enhanced Scaling FPC4, as shown in
.
Figure 36: T640 Enhanced Scaling FPC4 Supported by the T1600 Router
90 Copyright © 2019, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
The T1600 router supports the T640 Enhanced Scaling FPC4-1P, as shown in
Figure 37: T640 Enhanced Scaling FPC4-1P Supported by the T1600 Router
Copyright © 2019, Juniper Networks, Inc.
91
T1600 Core Router Hardware Guide
The T1600 router supports the T1600 Enhanced Scaling FPC4, as shown in
Figure 38: T1600 Enhanced Scaling FPC4 Supported by the T1600 Router
Related
Documentation
•
Packet Forwarding Engine Architecture for T Series Routers on page 8
•
T1600 FPCs Supported on page 92
•
Maintaining T1600 FPCs on page 514
•
Troubleshooting the T1600 FPCs on page 551
T1600 FPCs Supported
lists the FPCs for the T1600 Core Routers. You can install any combination of the FPCs currently supported. First Junos OS Release Supported indicates the first release that the FPC is supported in the T1600 router.
92 Copyright © 2019, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
NOTE: End of life (EOL) indicates that the product has been removed from the price list and is no longer available for purchase. End of support (EOS) indicates that no new support contracts are available on these products and the last contract will expire on the EOS date associated with each product.
For more information about EOS or EOL products, see the product support notification (PSN) hardware end-of-life announcements.
https://www.juniper.net/documentation/hardware/eol.html
Table 48: FPCs Supported by the T1600 Router
1
FPC Type
2
FPC Name
FPC Model
Number
Enhanced FPC1
EOL details:
PSN-2007-12-035
T640-FPC1-E
Enhanced II FPC1
EOL details:
PSN-2010-08-920
T640-FPC1-E2
Enhanced Scaling
FPC1
T640-FPC1-ES
FPC2
EOS details:
PSN-2004-05-010
T640-FPC2
Enhanced FPC2
EOL details:
PSN-2007-12-035
T640-FPC2-E
Enhanced II FPC2
EOL details:
PSN-2010-08-920
T640-FPC2-E2
Enhanced Scaling
FPC2
T640-FPC2-ES
Maximum
Number of PICs
Maximum
Throughput per
FPC
First Junos OS
Release
Supported
4 4 Gbps
4
4
4
4
4
4
4 Gbps
4 Gbps
16 Gbps
16 Gbps
16 Gbps
16 Gbps
Standalone: 8.5
Routing matrix:
10.0
Standalone: 8.5
Routing matrix:
10.0
Standalone: 9.4
Routing matrix:
10.0
Standalone: 8.5
Routing matrix:
10.0
Standalone: 8.5
Routing matrix:
10.0
Standalone: 8.5
Routing matrix:
10.0
Standalone: 9.5
Routing matrix:
10.0
Copyright © 2019, Juniper Networks, Inc.
93
T1600 Core Router Hardware Guide
Table 48: FPCs Supported by the T1600 Router (continued)
FPC Type FPC Name
FPC Model
Number
Maximum
Number of PICs
Maximum
Throughput per
FPC
First Junos OS
Release
Supported
3 4 40 Gbps 8.5
FPC3
EOS details:
PSN-2004-05-010
T640-FPC3
Enhanced FPC3
EOL details:
PSN-2007-12-035
T640-FPC3-E
Enhanced II FPC3
EOL details:
PSN-2010-08-920
T640-FPC3-E2
4
4
40 Gbps
40 Gbps
8.5
8.5
4
Enhanced Scaling
FPC3
T640-FPC3-ES
T640 Enhanced
Scaling FPC4
EOL details:
PSN-2010-07-878
T640-FPC4-ES
4
1
Enhanced Scaling
FPC4-1P
T640-FPC4-1P-ES 1
40 Gbps
50 Gbps
50 Gbps
9.0
8.5
T1600 Enhanced
Scaling FPC4
T1600-FPC4-ES 2 100 Gbps
Standalone: 9.5
Routing matrix:
10.0
8.5
Related
Documentation
•
Packet Forwarding Engine Architecture for T Series Routers on page 8
•
T1600 Flexible PIC Concentrator (FPC) Description on page 81
•
Maintaining T1600 FPCs on page 514
•
Troubleshooting the T1600 FPCs on page 551
T1600 PIC Description
PICs provide the physical connection to various network media types, receiving incoming packets from the network and transmitting outgoing packets to the network. During this process, each PIC performs framing and line-speed signaling for its media type. Before transmitting outgoing data packets, the PICs encapsulate the packets received from the
FPCs. Each PIC is equipped with an ASIC that performs control functions specific to the media type of that PIC.
94 Copyright © 2019, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
PICs are hot-removable and hot-insertable. You can install up to four PICs in each Type
1, 2, and 3 FPC, one PIC in each T640 Enhanced Scaling FPC4 or Enhanced Scaling
FPC4-IP, and one or two PICs in each T640 Enhanced Scaling FPC4. Type 1 and Type 2
PICs have captive screws at their upper and lower corners. Type 3 PICs have an upper ejector handle and a lower captive screw. Type 4 PICs have an upper ejector handle and a lower ejector handle.
The router supports various PICs, including ATM, Channelized, Gigabit Ethernet, IP Services, and SONET/SDH interfaces. Blank PICs resemble other PICs but do not provide any physical connection or activity. When a slot is not occupied by a PIC, you must insert a blank PIC to fill the empty slot and ensure proper cooling of the system.
Related
Documentation
•
T1600 PIC Combination Limitations on page 105
•
Packet Forwarding Engine Architecture for T Series Routers on page 8
•
Maintaining T1600 PICs and PIC Cables on page 523
•
Troubleshooting the T1600 PICs on page 555
T1600 PICs Supported
through
list the PICs supported by the T1600 router by PIC family.
NOTE: The T1600 router is now end-of-life. See the JTAC support bulletin
TSB16822 for additional information about the PICs and other associated
FRUs that moved to end-of-life with the router. The
topic lists PICs that moved to end-of-life before the
T1600 router itself moved to end-of-life.
•
•
•
•
•
Gigabit Ethernet PICs on page 98
•
10-Gigabit Ethernet PICs on page 101
•
40-Gigabit Ethernet PICs on page 102
•
100-Gigabit Ethernet PICs on page 102
•
•
ATM2 IQ PICs
lists the ATM2 IQ PICs supported by the T1600 router.
Copyright © 2019, Juniper Networks, Inc.
95
T1600 Core Router Hardware Guide
Table 49: ATM2 IQ PICs Supported by the T1600 Router
PIC Family and Type
ATM2 E3 IQ PIC (T1600
Router)
Ports Model Number
4 PB-2E3-ATM2
Connectors
Coaxial:
•
•
10 ft (3.05 m) posilock
SMB to BNC cable
(provided)
Four pairs of Rx and Tx coaxial cables
• Optical: SC/PC
First Junos OS
Release
Support
8.5
ATM2 OC3/STM1 IQ PIC
(T1600 Router)
ATM2 OC12/STM4 IQ PICs
(T1600 Router)
• ATM2 OC12/STM4 IQ PIC
2
2
PB-2OC3-ATM2-MM
PB-2OC3-ATM2-SMIR
8.5
• ATM2 OC12/STM4 IQ PIC 1
PB-2OC12-ATM2-MM
PB-2OC12-ATM2-SMIR
PB-1OC12-ATM2-MM
PB-1OC12-ATM2-SMIR
PB-1OC48-ATM2-SFP
• Optical: SC/PC
• Optical: SC/PC
8.5
8.5
ATM2 OC48/STM16 IQ PIC with SFP (T1600 Router)
1 • Optical: LC/PC 8.5
Channelized PICs
•
lists the channelized IQ PICs supported by T1600 router.
•
lists the enhanced channelized IQ (IQE) PICs supported by T1600 router.
Table 50: Channelized IQ PICs Supported by the T1600 Router
PIC Family and Type Ports Model Number Connectors
First Junos OS
Release
Support
Channelized DS3 IQ PIC
(T1600 Router)
4
1
PB-4CHDS3-QPP
PB-1CHOC3-SMIR-QPP
Coaxial
• Standard DS3 BNC coaxial cable interfaces
8.5
• Optical: SC/PC 8.5
Channelized OC3 IQ PIC
(T1600 Router)
Channelized STM1 IQ PIC
(T1600 Router)
1 PB-1CHSTM1-SMIR-QPP • Optical: SC/PC 8.5
96 Copyright © 2019, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 51: Channelized Enhanced IQ (IQE) PICs Supported by the T1600 Router
PIC Family and Type Ports Model Number Connectors
First Junos OS
Release
Support
Channelized DS3/E3 Enhanced
IQ (IQE) PIC (T1600 Router)
Channelized E1/T1 Enhanced
IQ (IQE) PIC (T1600 Router)
4
10
PB-4CHDS3-E3-IQE-BNC
PB-1OCHE1-T1-IQE-RJ48
Coaxial
• Standard DS3 BNC coaxial cable interfaces
9.3
9.5
• 120-ohm RJ-48C connector (female)
• Optical: LC/PC 9.3
Channelized OC3/STM1
Enhanced IQ (IQE) PIC with
SFP (T1600 Router)
2 PB-2CHOC3-STM1-IQE-SFP
Channelized OC12/STM4 Enhanced IQ (IQE) PICs with SFP (T1600 Router)
PB-1CHOC12-STM4-IQE-SFP • Channelized OC12/STM4
Enhanced IQ (IQE) PIC with
SFP
1
• Channelized OC12/STM4
Enhanced IQ (IQE) PIC with
SFP (Type 2)
4
• Channelized OC12/STM4
Enhanced IQ (IQE) PIC with
SFP (Type 3)
4
Channelized OC48/STM16
Enhanced IQ (IQE) PIC with
SFP (T1600 Router)
1
PB-4CHOC12-STM4-IQE-SFP
PC-4CHOC12STM4-IQE-SFP
PB-1CHOC48-STM16-IQE-SFP
•
•
•
Optical: LC/PC
Optical: LC/PC
Optical: LC/PC
• Optical: LC/PC
9.3
9.4
10.1
9.4
DS3 and E3 PICs
lists the DS3 and E3 PICs supported by T1600 router.
Table 52: DS3 and E3 PICs Supported by the T1600 Router
PIC Family and Type Ports Model Number Connectors
First Junos OS
Release
Support
DS3/E3 Enhanced IQ (IQE) PIC
(T1600 Router)
4 PB-4DS3-E3-IQE-BNC
E3 IQ PIC (T1600 Router) 4 PB-4E3-QPP
Coaxial
• Standard DS3 BNC coaxial cable interfaces
9.3R2
Coaxial
• Standard DS3 BNC coaxial cable interfaces
8.5
Copyright © 2019, Juniper Networks, Inc.
97
T1600 Core Router Hardware Guide
Fast Ethernet PICs
lists the Fast Ethernet PICs supported by T1600 router.
Table 53: Fast Ethernet PICs Supported by the T1600 Router
PIC Family and Type Ports Model Number Connectors
First Junos OS
Release
Support
Fast Ethernet PIC (T1600
Router)
4 PB-4FE-TX •
•
•
RJ-45
Two-pair, Category 5 unshielded twisted-pair
Pinout: MDI noncrossover
8.5
Gigabit Ethernet PICs
•
lists the Gigabit Ethernet PICs supported by T1600 router.
•
lists the Gigabit Ethernet IQ PICs supported by T1600 router.
•
lists the Gigabit Ethernet IQ2 PICs supported by T1600 router.
•
lists the Gigabit Ethernet Enhanced IQ2 PICs supported by T1600 router.
Table 54: Gigabit Ethernet PICs Supported by the T1600 Router
PIC Family and Type Ports Model Number Connectors
First Junos OS
Release
Support
Gigabit Ethernet PICs with SFP
(T1600 Router)
• Gigabit Ethernet PIC with
SFP
1 PB-1GE-SFP 8.5
• Gigabit Ethernet PIC with
SFP
2 PB-2GE-SFP
•
•
Optical: LC
Copper: RJ-45
•
•
Four-pair, Category 5 shielded twisted-pair connectivity
Pinout: MDI crossover
•
•
Optical: LC
Copper: RJ-45
•
•
Four-pair, Category 5 shielded twisted-pair connectivity
Pinout: MDI crossover
8.5
98 Copyright © 2019, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 54: Gigabit Ethernet PICs Supported by the T1600 Router (continued)
PIC Family and Type
• Gigabit Ethernet PIC with
SFP
Ports Model Number
4
• Gigabit Ethernet PIC with
SFP
10
PB-4GE-SFP
PC-10GE-SFP
Connectors
•
•
Optical: LC
Copper: RJ-45
• Four-pair, Category 5 shielded twisted-pair connectivity
• Pinout: MDI crossover
•
•
Optical: LC
Copper: RJ-45
•
•
Four-pair, Category 5 shielded twisted-pair connectivity
Pinout: MDI crossover
First Junos OS
Release
Support
8.5
8.5
Table 55: Gigabit Ethernet IQ
Connectors
First Junos OS
Release
Support PIC Family and Type Ports Model Number
Gigabit Ethernet IQ PICs with SFP (T1600 Router)
• Gigabit Ethernet IQ PIC with
SFP
1 PB-1GE-SFP-QPP
• Gigabit Ethernet IQ PIC with
SFP
2 PB-2GE-SFP-QPP
•
•
Optical: LC
Copper: RJ-45
•
•
Four-pair, Category 5 shielded twisted-pair connectivity
Pinout: MDI crossover
•
•
Optical: LC
Copper: RJ-45
• Four-pair, Category 5 shielded twisted-pair connectivity
• Pinout: MDI crossover
8.5
8.5
Copyright © 2019, Juniper Networks, Inc.
99
T1600 Core Router Hardware Guide
Table 56: Gigabit Ethernet IQ2
• Type 3 Gigabit Ethernet IQ2
PIC with SFP
8 PB-8GE-TYPE3-SFP-IQ2
First Junos OS
Release
Support PIC Family and Type Ports Model Number
Gigabit Ethernet IQ2 PICs with
SFP (T1600 Router)
• Type 1 Gigabit Ethernet IQ2
PIC with SFP
4 PB-4GE-TYPE1-SFP-IQ2
• Type 2 Gigabit Ethernet IQ2
PIC with SFP
8 PB-8GE-TYPE2-SFP-IQ2
Connectors
•
•
Optical: LC
Copper: RJ-45
• Four-pair, Category 5 shielded twisted-pair connectivity
• Pinout: MDI crossover
•
•
Optical: LC
Copper: RJ-45
•
•
Four-pair, Category 5 shielded twisted-pair connectivity
Pinout: MDI crossover
•
•
Optical: LC
Copper: RJ-45
•
•
Four-pair, Category 5 shielded twisted-pair connectivity
Pinout: MDI crossover
8.5
8.5
8.5
Table 57: Gigabit Ethernet IQ2E PICs
PIC Family and Type Ports Model Number
Gigabit Ethernet Enhanced IQ2
(IQ2E) PICs with SFP (T1600
Router)
• Type 1 Gigabit Ethernet
Enhanced IQ2 (IQ2E) PIC with SFP
4 PB-4GE-TYPE1-SFP-IQ2E
Connectors
First Junos OS
Release
Support
•
•
Optical: LC
Copper: RJ-45
• Four-pair, Category 5 shielded twisted-pair connectivity
• Pinout: MDI crossover
9.4
100 Copyright © 2019, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 57: Gigabit Ethernet IQ2E PICs (continued)
PIC Family and Type
• Type 2 Gigabit Ethernet
Enhanced IQ2 (IQ2E) PIC with SFP
Ports Model Number
8 PB-8GE-TYPE2-SFP-IQ2
• Type 3 Gigabit Ethernet
Enhanced IQ2 (IQ2E) PIC with SFP
8 PB-8GE-TYPE3-SFP-IQ2
Connectors
•
•
Optical: LC
Copper: RJ-45
• Four-pair, Category 5 shielded twisted-pair connectivity
• Pinout: MDI crossover
•
•
Optical: LC
Copper: RJ-45
•
•
Four-pair, Category 5 shielded twisted-pair connectivity
Pinout: MDI crossover
First Junos OS
Release
Support
9.4
9.4
10-Gigabit Ethernet PICs
lists the 10-Gigabit Ethernet PICs supported by T1600 router.
Table 58: 10-Gigabit Ethernet PICs Supported by the T1600 Router
PIC Family and Type Ports Model Number Connectors
First Junos OS
Release
Support
PC-1XGE-TYPE3-XFP-IQ2 • Optical: LC 8.5
10-Gigabit Ethernet IQ2 PIC with XFP (T1600 Router)
1
10-Gigabit Ethernet Enhanced
IQ2 (IQ2E) PIC with XFP
(T1600 Router)
1
10-Gigabit Ethernet PIC with
XENPAK (T1600 Router)
1
10-Gigabit Ethernet DWDM PIC
(T1600 Router)
1
10-Gigabit Ethernet DWDM
OTN PIC (T1600 Router)
1
10-Gigabit Ethernet LAN/WAN
PIC with Oversubscription and
SFP+ (T1600 Router)
10
10-Gigabit Ethernet LAN/WAN
PIC with XFP (T1600 Router)
4
PC-1XGE-TYPE3-XFP-IQ2E
PC-1XGE-XENPAK
PC-1XGE-DWDM-CBAND
PC-1XGE-DWDM-OTN
PD-5-10XGE-SFPP
PD-4XGE-XFP
• Optical: LC
• XENPAK
• Optical: SC
• Optical: SC
• Optical: LC
• Optical: LC
9.4
8.5
8.5
9.4
10.1
9.0
Copyright © 2019, Juniper Networks, Inc.
101
T1600 Core Router Hardware Guide
40-Gigabit Ethernet PICs
lists the 40-Gigabit Ethernet PICs supported by T1600 router.
Table 59: 40-Gigabit Ethernet PICs Supported by the T1600 Router
PIC Family and Type Ports Model Number Connectors
First Junos OS
Release
Support
40-Gigabit Ethernet
40-Gigabit Ethernet PIC with
CFP (T1600 Router)
4 PD-1XLE-CFP Optical: SC 11.4
100-Gigabit Ethernet PICs
lists the 100-Gigabit Ethernet PICs supported by T1600 router.
Table 60: 100-Gigabit Ethernet PICs Supported by the T1600 Router
PIC Family and Type Ports Model Number Connectors
First Junos OS
Release
Support
100-Gigabit Ethernet PIC with
CFP (T1600 Router)
1 PD-1CE-CFP-FPC4 (PIC and
FPC)
NOTE: This PIC is only available packaged in an assembly with the T1600-FPC4-ES FPC.
• Optical: SC 10.3
Services PICs
lists the Services PICs supported by T1600 router.
Table 61: Services PICs Supported by the T1600 Router
Connectors
First Junos OS
Release
Support PIC Family and Type Ports Model Number
Services
MultiServices PICs (T1600 Router)
• MultiServices 100 PIC
• MultiServices400 PIC
0
0
• MultiServices 500 PIC 0
Tunnel Services PIC (T1600 Router)
• Type 1 Tunnel Services PIC 0
PB-MS-100-1
PB-MS-400-2
PB-MS-500-3
PB-TUNNEL-1
• None
• None
• None
• None
8.5
8.5
8.5
8.5
102 Copyright © 2019, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 61: Services PICs Supported by the T1600 Router (continued)
PIC Family and Type Ports Model Number
• Type 2 Tunnel Services PIC 0
• Type 3 Tunnel Services PIC 0
40-Gigabit Tunnel Services PIC
(T1600 Router)
0
PB-TUNNEL
PC-TUNNEL
PD-TUNNEL
SONET/SDH PICs
Table 62: SONET/SDH PICs Supported by the T1600 Router
Connectors
• None
• None
• None
PIC Family and Type Ports Model Number
SONET/SDH OC3/STM1
Enhanced IQ (IQE) PIC with
SFP (T1600 Router)
4 PB-4OC3-STM1-IQE-SFP
SONET/SDH OC3/STM1 (Multi-Rate) PICs with SFP (T1600 Router)
• Type 1 SONET/SDH
OC3/STM1 (Multi–Rate)
PIC with SFP
• Type 2 SONET/SDH
OC3/STM1 (Multi–Rate)
PIC with SFP
SONET/SDH OC12/STM4
Enhanced IQ (IQE) PIC with
SFP (T1600 Router)
4
4
1
PB-4OC3-1OC12-SON-SFP
PB-4OC3-1OC12-SON2-SFP
PB-1OC12-STM4-IQE-SFP
SONET/SDH OC12/STM4 (Multi-Rate) PICs with SFP (T1600 Router)
• SONET/SDH OC12/STM4
(Multi–Rate) PIC with SFP
1
• SONET/SDH OC12/STM4
(Multi–Rate) PIC with SFP
4
SONET/SDH OC48c/STM16
PIC with SFP (T1600 Router)
4
PB-1OC12-SON-SFP
PB-4OC3-40C12-SON-SFP
PC-4OC48-SON-SFP
SONET/SDH OC48/STM16
Enhanced IQ (IQE) PIC with
SFP (T1600 Router)
4 PC-4OC48-STM16-IQE-SFP
Connectors
• Optical: LC
• Optical: LC
• Optical: LC
• Optical: LC
• Optical: LC
• Optical: LC
• Optical: LC
• Optical: LC
8.5
8.5
9.3
8.5
8.5
8.5
10.4R2
First Junos OS
Release
Support
8.5
8.5
8.5
First Junos OS
Release
Support
9.3R2
Copyright © 2019, Juniper Networks, Inc.
103
T1600 Core Router Hardware Guide
Table 62: SONET/SDH PICs Supported by the T1600 Router (continued)
PIC Family and Type
SONET/SDH OC48/STM16
(Multi-Rate) PIC with SFP
(T1600 Router)
1
SONET/SDH OC192c/STM64
PIC (T1600 Router)
1
SONET/SDH OC192/STM64
PICs with XFP (T1600 Router)
1
SONET/SDH OC192/STM64
PICs with XFP (T1600 Router)
4
SONET/SDH OC768c/STM256
PIC (T1600 Router)
1
Ports Model Number
PB-1OC48-SON-B-SFP
PC-1OC192-SON-VSR
PC-1OC192-SON-XFP
PD-4OC192-SON-XFP
PD-1OC768-SON-SR
Connectors
• Optical: LC
• Optical: LC
• Optical: LC
• Optical: LC
• Optical: SC
8.5
8.5
8.5
8.5
First Junos OS
Release
Support
8.5
Related
Documentation
•
T1600 PIC Description on page 94
•
T1600 PIC Combination Limitations on page 105
•
T1600 FPCs Supported on page 92
T1600 End-of-Life PICs Supported
lists the end-of-life PICs supported by the T1600 router. The PICs are listed alphabetically by PIC family.
NOTE: The T1600 router is now end-of-life. See the JTAC support bulletin
TSB16822 for additional information about the PICs and other associated
FRUs that moved to end-of-life with the router. The
“T1600 PICs Supported” on page 95
topic lists PICs that had not moved to end-of-life before the T1600 router itself moved to end-of-life.
Table 63: End-of-Life PICs Supported in the T1600 Router
PIC Family and Type
Channelized IQ
Channelized OC12 IQ EOL PIC (T1600 Router)
DS3/E3
1
Ports Model Number
PE-1CHOC12SMIR-QPP
Connector
• Optical: SC/PC
104 Copyright © 2019, Juniper Networks, Inc.
First Junos OS
Release
Support
8.5
Chapter 6: Line Card Components and Descriptions
Table 63: End-of-Life PICs Supported in the T1600 Router (continued)
PIC Family and Type
DS3 EOL PIC (T1600 Router)
Ports Model Number
4 PB-2DS3
Connector
First Junos OS
Release
Support
• Custom 10 ft (3.05 m) posilock
SMB to BNC male cable, separate
Rx and Tx (provided)
8.5
Services
Adaptive Services II EOL PIC (T1600 Router)
Adaptive Services II Layer 2 Services EOL PIC (T1600
Router)
Link Services EOL PIC (T1600 Router)
0
0
0
PB-AS2
PB-AS2-LAYER2SERVICES
PB-LS-4
PB-LS-32
PB-LS-128
PB-PM2
PB-PM3
• None
• None
• None
Monitoring Services II EOL PIC (T1600 Router)
Monitoring Services III EOL PIC (T1600 Router)
SONET/SDH
SONET/SDH OC3c/STM1 EOL PICs (T1600 Router) 4
SONET/SDH OC12c/STM4 EOL PICs (T1600 Router)
• SONET/SDH OC12c/STM4 PIC
• SONET/SDH OC12c/STM4 PIC
SONET/SDH OC48c/STM16 EOL PIC with SFP (T1600
Router)
1
1
4
0
0
PB-4OC3-SON-MM
PB-4OC3-SON-SMIR
PB-1OC12-SON-MM
PB-4OC12-SON-MM
PB-4OC12-SON-SMIR
PB-1OC48-SON-SFP
• None
• None
• Optical: SC/PC
• Optical: SC/PC
• Optical: SC/PC
• Optical: LC/PC
Related
Documentation
•
T1600 PIC Description on page 94
T1600 PIC Combination Limitations
In most cases, you can install PICs of different media types on the same FPC as long as the FPC and the router support those PICs. However, configuration rules might limit certain combinations of PICs on some platforms.
Newer Junos OS services for some PICs can require significant Internet Processor ASIC memory. Ethernet and SONET PICs typically do not use large amounts of memory. Gigabit
Ethernet, ATM2, IQ serial PICs, and Multiservices PICs use more. To conserve memory, you can group PICs in the same family together on the same FPC.
8.5
8.5
8.5
8.5
8.5
6.1
8.5
8.5
8.5
Copyright © 2019, Juniper Networks, Inc.
105
T1600 Core Router Hardware Guide
If you have different PIC families on a single FPC, review the configuration rules to plan which PICs to install on the FPCs for your router. Consult technical bulletin
PSN-2007-01-023 for information about configuration rules for PIC combinations on the
Juniper Networks Support site at https://www.juniper.net/alerts/ .
When you upgrade to Junos OS Release 7.5 or later, a warning appears if any configuration rules affect your PIC combinations. If you continue the installation, one or more PICs might appear to be online (the LEDs are on), but the Junos OS cannot enable them and they cannot pass traffic. As a workaround, you can:
• Install a Junos OS release that supports the combination.
• Install PICs on a different FPC.
• Remove PICs from the affected FPC.
Related
Documentation
•
T1600 PIC Description on page 94
•
T1600 PICs Supported on page 95
•
T1600 FPCs Supported on page 92
•
T1600 PIC/FPC Compatibility on page 106
T1600 PIC/FPC Compatibility
The PIC/FPC compatibility matrixes list the current PICs for the T1600 router. For example,
Junos OS Release 8.5 is the first release in which the T640-FPC1-E2 supports the ATM2
OC3/STM1 IQ, 2-port PIC.
NOTE: A – indicates that the FPC does not support the PIC.
•
PIC/FPC Compatibility (Type 1 FPCs and Type 1 PICs) on page 106
•
PIC/FPC Compatibility (Type 2 FPCs and Type 2 PICs) on page 108
•
PIC/FPC Compatibility (Type 3 FPCs and Type 3 PICs) on page 110
•
PIC/FPC Compatibility (Type 4 FPCs and Type 4 PICs) on page 111
PIC/FPC Compatibility (Type 1 FPCs and Type 1 PICs)
provides a PIC/FPC compatibility matrix for the current Type 1 PICs for the T1600 router and Type 1 FPCs.
NOTE: A T1600 router in a routing matrix supports Type 1 PICs in Junos OS
Release 10.0 and later.
106 Copyright © 2019, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 64: T1600 PIC/FPC Compatibility Type 1
Type 1 PIC PIC Model Number
ATM2 IQ PICs
ATM2 E3 IQ, 4-port PB-4E3-ATM2
ATM2 OC3/STM1 IQ, 2-port PB-2OC3-ATM2-MM
PB-2OC3-ATM2-SMIR
ATM2 OC12/ STM4 IQ,
1-port
PB-1OC12-ATM2-MM
PB-1OC12-ATM2-SMIR
Channelized IQ PICs
ChDS3 IQ, 4-port
ChOC3 IQ, 1-port
ChSTM1 IQ, 1-port
PB-4CHDS3-QPP
PB-1CHOC3-SMIR-QPP
PB-1CHSTM1-SMIR-QPP
Channelized IQE PICs
ChDS3/E3 IQE, 4-port
ChE1/T1 IQE, 10-port
PB-4CHDS3-E3-IQE-BNC
PB-1OCHE1-T1-IQE-RJ48
ChOC3/STM1 IQE, 2-port PB-2CHOC3-STM1-IQE-SFP
ChOC12/STM4 IQE, 1-port PB-1CHOC12-STM4-IQE-SFP
DS3 and E3 PICs
DS3/E3 IQE, 4-port
E3 IQ, 4-port
PB-4DS3-E3-IQE-BNC
PB-4E3-QPP
Fast Ethernet and Gigabit Ethernet PICs
Fast Ethernet, 4-port PB-4FE-TX
T640-FPC1-E
8.5
8.5
8.5
8.5
8.5
8.5
9.3
9.5
9.3
9.3
9.3R2
8.5
8.5
T640-FPC1-E2 T640-FPC1-ES
8.5
8.5
8.5
9.3
9.5
9.3
9.3
8.5
8.5
8.5
9.3R2
8.5
8.5
–
–
–
9.4
9.5
9.4
9.4
9.4
9.4
9.4
9.4
–
9.4
Copyright © 2019, Juniper Networks, Inc.
107
T1600 Core Router Hardware Guide
Table 64: T1600 PIC/FPC Compatibility Type 1 (continued)
Type 1 PIC PIC Model Number T640-FPC1-E
Gigabit Ethernet, 1-port SFP PB-1GE-SFP 8.5
Gigabit Ethernet IQ PICs
Gigabit Ethernet IQ, 1-port
SFP
PB-1GE-SFP-QPP 8.5
Gigabit Ethernet IQ2 PICs
Gigabit Ethernet IQ2, 4-port
SFP
PB-4GE-TYPE1-SFP-IQ2
Gigabit Ethernet IQ2E PICs
Gigabit Ethernet IQ2E,
4-port SFP
PB-4GE-TYPE1-SFP-IQ2E
8.5
9.4
Services PICs
MultiServices 100
Tunnel Services
PB-MS-100-1
PB-TUNNEL1
SONET/SDH PICs
OC3/STM1 IQE, 4-port SFP PB-4OC3-STM1-IQE-SFP
OC3c/STM1 (Multi-Rate)
4-port (Type 1)
PB-4OC3-1OC12-SON-SFP
OC12/STM4 IQE, 1-port SFP PB-1OC12-STM4-IQE-SFP
OC12c/STM4 (Multi-Rate)
1-port (Type 1)
PB-1OC12-SON-SFP
8.5
8.5
9.3R2
8.5
9.3
8.5
T640-FPC1-E2 T640-FPC1-ES
8.5
9.4
8.5
8.5
9.4
8.5
8.5
9.3R2
8.5
9.3
8.5
–
9.4
–
9.4
9.4
–
9.4
–
9.4
PIC/FPC Compatibility (Type 2 FPCs and Type 2 PICs)
provides a PIC/FPC compatibility matrix for the current Type 2 PICs for the T1600 router and Type 2 FPCs.
NOTE: A T1600 router in a routing matrix supports Type 2 PICs in Junos OS
Release 10.0 and later.
Table 65: T1600 PIC/FPC Compatibility Type 2
PIC PIC Model Number
ATM2 IQ PICs
T640-FPC2 T640-FPC2-E T640-FPC2-E2 T640-FPC2-ES
108 Copyright © 2019, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 65: T1600 PIC/FPC Compatibility Type 2 (continued)
PIC PIC Model Number T640-FPC2 T640-FPC2-E T640-FPC2-E2 T640-FPC2-ES
ATM2 OC12/ STM4 IQ,
1-port
PB-1OC12-ATM2-MM
PB-1OC12-ATM2-SMIR
8.5
8.5
8.5
–
ATM2 OC48/ STM16 IQ,
1-port SFP
PB-1OC48-ATM2-SFP 8.5
8.5
8.5
–
Channelized IQE PICs
ChOC12/STM4 IQE, 4-port PB-4CHOC12-STM4-IQE-SFP –
ChOC48/STM16 IQE, 1-port PB-1CHOC48-STM16-IQE-SFP –
Gigabit Ethernet PICs
Gigabit Ethernet, 2-port SFP PB-2GE-SFP
Gigabit Ethernet, 4-port SFP PB-4GE-SFP
8.5
8.5
Gigabit Ethernet IQ PICs
Gigabit Ethernet IQ, 2-port
SFP
PB-2GE-SFP-QPP
Gigabit Ethernet IQ2 PICs
Gigabit Ethernet IQ2, 8-port
SFP (Type 2)
PB-8GE-TYPE2-SFP-IQ2
8.5
–
9.4
9.4
8.5
8.5
8.5
8.5
9.4
9.4
8.5
8.5
8.5
8.5
9.5
9.5
9.5
9.5
–
9.5
Gigabit Ethernet IQ2E PICs
Gigabit Ethernet IQ2E,
8-port SFP (Type 2)
PB-8GE-TYPE2-SFP-IQ2E
Services PICs
MultiServices 400 PB-MS-400-2
–
OC48/STM16 (Multi-Rate)
4-port (Type 2)
PB-1OC48-SON-B-SFP
–
Tunnel Services
SONET/SDH PICs
OC3c/STM1 (Multi-Rate)
4-port (Type 2)
PB-TUNNEL
PB-4OC3-1OC12-SON2-SFP –
OC12c/STM4 (Multi-Rate)
4-port (Type 2)
PB-4OC3-4OC12-SON-SFP
OC48c/STM16, 1-port SFP PB-1OC48-SON-SFP
8.5
–
8.5
–
9.4
8.5
8.5
8.5
8.5
8.5
8.5
9.4
8.5
8.5
8.5
8.5
8.5
8.5
–
9.5
9.5
–
9.5
–
9.5
Copyright © 2019, Juniper Networks, Inc.
109
T1600 Core Router Hardware Guide
PIC/FPC Compatibility (Type 3 FPCs and Type 3 PICs)
provides a PIC/FPC compatibility matrix for the current Type 3 PICs for the T1600 router and Type 3 FPCs.
NOTE: A T1600 router in a routing matrix supports Type 3 PICs in Junos OS
Release 9.6R2 and later.
Table 66: T1600 PIC/FPC Compatibility Type 3
Type 3 PIC PIC Model Number T640-FPC3 T640-FPC3-E T640-FPC3-E2 T640-FPC3-ES
Channelized IQE PICs
ChOC12/STM4
IQE, 4-port
PC-4CHOC12-STM4-IQE-SFP –
Gigabit Ethernet PICs
Gigabit Ethernet,
10-port SFP
PC-10-GE-SFP 8.5
Gigabit Ethernet IQ2 PICs
Gigabit Ethernet
IQ2, 8-port SFP
(Type 3)
PC-8GE-TYPE3-SFP-IQ2
10-Gigabit
Ethernet IQ2,
1-port XFP
8.5
PC-1XGE-TYPE3-XFP-IQ2 8.5
–
8.5
8.5
8.5
–
8.5
8.5
8.5
10.1
9.0
9.0
9.0
Gigabit Ethernet and 10-Gigabit Ethernet IQ2E PICs
Gigabit Ethernet
IQ2E, 8-port SFP
(Type 3)
PC-8GE-TYPE3-SFP-IQ2E 9.4
10-Gigabit
Ethernet IQ2E,
1-port XFP
PC-1XGE-TYPE3-XFP-IQ2E 9.4
10-Gigabit Ethernet PICs
10-Gigabit
Ethernet, 1-port
XENPAK
PC-1XGE-XENPAK with
10GBase-ER and
10GBASE-LR transceivers installed
8.5
PC-1XGE-XENPAK with
10GBASE-SR and
10GBASE-ZR transceivers installed
8.5
9.4
9.4
8.5
8.5
9.4
9.4
8.5
8.5
9.4
9.4
9.0
9.0
110 Copyright © 2019, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 66: T1600 PIC/FPC Compatibility Type 3 (continued)
Type 3 PIC PIC Model Number T640-FPC3 T640-FPC3-E
PC-1XGE-DWDM-CBAND 8.5
8.5
10-Gigabit
Ethernet, 1-port
DWDM
10-Gigabit
Ethernet, 1-port
DWDM OTN
PC-1XGE-DWDM-OTN 9.4
9.4
T640-FPC3-E2 T640-FPC3-ES
8.5
9.0
9.4
9.4
Services PICs
MultiServices 500 PC-MS-500-3
Tunnel Services PC-TUNNEL
–
8.5
SONET/SDH PICs
OC48/STM16 IQE,
4-port SFP
PC-4OC48-STM16-IQE-SFP in a standalone T1600 router
–
This PIC is not supported in a T1600 router connected to a TX Matrix Plus router.
8.5
OC48c/STM16,
4-port SFP
PC-4OC48-SON-SFP
OC192c /STM64,
1-port
PC-1OC192-SON-VSR
OC192 /STM64,
1-port XFP
PC-1OC192-SON-XFP
8.5
–
8.5
8.5
–
8.5
8.5
8.5
8.5
8.5
–
8.5
8.5
8.5
9.3
9.0
10.4R2
9.0
9.0
9.0
PIC/FPC Compatibility (Type 4 FPCs and Type 4 PICs)
provides a PIC/FPC compatibility matrix for the current Type 4 PICs for the T1600 router and Type 4 FPCs.
NOTE: A T1600 router in a routing matrix supports Type 4 PICs in Junos OS
Release 9.6R2 and later.
Table 67: T1600 PIC/FPC Compatibility Type 4
Type 4 PIC PIC Model Number
10-Gigabit Ethernet PICs
10-Gigabit Ethernet,
4-port LAN/WAN
XFP
PD-4XGE-XFP
T640-FPC4-ES
9.0
T1600-FPC4-ES
9.0
T640-FPC4-1P-ES
9.5
Copyright © 2019, Juniper Networks, Inc.
111
T1600 Core Router Hardware Guide
Table 67: T1600 PIC/FPC Compatibility Type 4 (continued)
Type 4 PIC PIC Model Number T640-FPC4-ES
10-Gigabit
LAN/WAN with
Oversubscription and SFP+
PD-5-10XGE-SFPP 10.1
T1600-FPC4-ES T640-FPC4-1P-ES
10.1
NOTE: To support
PD-5-10XGE-SFPP, the hardware version of the
T1600-FPC4-ES
(part number
710-013037) REV
13 or later is required.
10.1
40-Gigabit Ethernet PICs
40-Gigabit with CFP PD-1XLE-CFP
100-Gigabit Ethernet PICs
100-Gigabit with
CFP
PD-1CE-CFP-FPC4 (PIC and FPC)
NOTE: This PIC is only available packaged in an assembly with the
T1600-FPC4-ES FPC.
Services PICs
40-Gigabit Tunnel
Services
PD-TUNNEL
SONET/SDH PICs
OC192/STM64,
4-port XFP
PD-4OC192-SON-XFP
OC768c/STM256,
1-port
PD-1OC768-SON-SR
–
–
8.5
8.5
8.5
11.4
–
8.5
8.5
8.5
11.4
10.3
9.5
9.5
9.5
Related
Documentation
•
T1600 PIC Description on page 94
•
T1600 PIC Combination Limitations on page 105
•
T1600 PICs Supported on page 95
•
T1600 FPCs Supported on page 92
112 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 7
Power System Components and
Descriptions
•
T1600 Power System Description on page 113
•
T1600 Three-Input 240-A DC Power Supply Description on page 114
•
T1600 Three-Input 240-A DC Power Supply LEDs on page 116
•
T1600 Four-Input 240-A DC Power Supply Description on page 117
•
T1600 Four-Input 240-A DC Power Supply LEDs on page 118
•
T1600 Six-Input DC Power Supply Description on page 119
•
T1600 Six-Input DC Power Supply LEDs on page 121
•
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
T1600 Three-Phase Delta and Wye AC Power Supply LEDs on page 124
T1600 Power System Description
The T1600 Core Router has two redundant, load-sharing power supplies, located at the lower rear of the chassis in slots PEM0 and PEM1 (top to bottom).
The power supplies connect to the midplane, which distributes the different output voltages produced by the power supplies to the T1600 router components, depending on their voltage requirements. For each output voltage that the power supply provides, it has either an active circuit breaker or an active current limiter.
NOTE: There are no passive fuses in the router that must be replaced.
Each power supply is cooled by its own internal cooling system. Power supplies are hot-removable and hot-insertable.
The T1600 router supports the power supplies in
NOTE: Redundant power supplies must be the same model number during normal operations.
Copyright © 2019, Juniper Networks, Inc.
113
T1600 Core Router Hardware Guide
Table 68: Supported Power Supplies
Name Model Number
Three-input 240-A DC power supplies PWR-T1600-3-80-DC
Four-input 240-A DC power supplies PWR-T1600-4-60-DC
Six-input DC power supplies
Three-phase delta AC power supply
Three-phase wye AC power supply
PWR-T-6-60-DC
PWR-T-10KW-DELTA-AC
PWR-T-10KW-WYE-AC
First Supported
Junos OS Release
8.5
9.6
11.4R2
10.0R2
10.0R2
Related
Documentation
•
T1600 Three-Input 240-A DC Power Supply Description on page 114
•
T1600 Four-Input 240-A DC Power Supply Description on page 117
•
T1600 Six-Input DC Power Supply Description on page 119
•
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
Maintaining the T1600 Power Supplies on page 525
•
Troubleshooting the T1600 Power System on page 552
•
T1600 DC Power Requirements on page 148
•
T1600 AC Power Requirements on page 157
T1600 Three-Input 240-A DC Power Supply Description
•
T1600 Three-Input 240-A DC Power Supply on page 114
•
T1600 Three-Input 240-A DC Power Supply Inputs on page 115
•
T1600 Three-Input 240-A DC Power Supply Load Sharing and Fault
T1600 Three-Input 240-A DC Power Supply
Each three-input 240-A DC power supply weighs approximately 25 lb (11.3 kg) and consists of three inputs, three 80-A circuit breakers, a fan, and LEDs to monitor the status of the power supply.
shows the three-input 240-A DC power supply.
114 Copyright © 2019, Juniper Networks, Inc.
Chapter 7: Power System Components and Descriptions
Figure 39: Three-Input 240-A DC Power Supply
T1600 Three-Input 240-A DC Power Supply Inputs
The three-input 240-A DC power supply inputs are labeled INPUT 0 , INPUT 1 , and INPUT 2 , from top to bottom. Each input consists of –48 VDC and return—each with its own 80-A circuit breaker. The input mode switch on the faceplate allows you to set the DC power supply to either 2-INPUT or 3-INPUT mode.
3-INPUT mode is required for the T1600 Core
Router.
describes which components are powered by each input.
Table 69: Components Powered by Each Three-Input 240-A DC Power Supply Input
Input
INPUT 0
Three-Input Mode
SIBs, control boards, fan trays, and Routing Engines
INPUT 1 FPCs in slots FPC4 through FPC7
INPUT 2 FPCs in slots FPC0 through FPC3
T1600 Three-Input 240-A DC Power Supply Load Sharing and Fault Tolerance
When the T1600 router is operating normally and both power supplies are switched on, load sharing between them occurs automatically. When one power supply fails or is turned off, the other power supply immediately assumes the entire electrical load for the system. A single power supply can provide full power for as long as the router is operational. At least one power supply needs all three inputs, INPUT 0 , INPUT 1 and INPUT
2 to function properly.
Related
Documentation
•
T1600 Power System Description on page 113
•
T1600 Three-Input 240-A DC Power Supply LEDs on page 116
Copyright © 2019, Juniper Networks, Inc.
115
T1600 Core Router Hardware Guide
•
Maintaining the T1600 Power Supplies on page 525
•
Troubleshooting the T1600 Power System on page 552
•
T1600 DC Power Requirements on page 148
T1600 Three-Input 240-A DC Power Supply LEDs
LEDs on each power supply faceplate (see
) indicate the status of the power supply. In addition, a power supply failure triggers the red alarm LED on the craft interface.
displays the power supply LEDs.
Figure 40: Three-Input 240-A DC Power Supply LEDs
116
Table 70: Three-Input 240-A DC Power Supply LEDs
LED Color State Description
CB ON —One per input
Green On steadily
Off
Circuit breaker is on.
Circuit breaker is not turned on, or host subsystem has detected a failure and has turned the circuit breaker off.
DC OK —One per power supply
Blue
INPUT
PRESENT —One per input
Green
On steadily
Blinking
On steadily
Off
When the power supply is correctly set to three-input mode and all three inputs are properly energized, the DC OK LED indicates that the power supply is functioning normally.
Power supply is starting up, is not functioning, is not properly installed, or is not operating properly.
Input is receiving voltage.
Input voltage is not present.
Copyright © 2019, Juniper Networks, Inc.
Chapter 7: Power System Components and Descriptions
Table 70: Three-Input 240-A DC Power Supply LEDs (continued)
LED Color State Description
On steadily OVER
TEMP —One per power supply
Yellow
Off
Power supply has exceeded recommended temperature.
Power supply is within the recommended temperature or the power supply is not on.
Related
Documentation
•
T1600 Three-Input 240-A DC Power Supply Description on page 114
•
T1600 DC Power Requirements on page 148
•
Maintaining the T1600 Power Supplies on page 525
•
Troubleshooting the T1600 Power System on page 552
T1600 Four-Input 240-A DC Power Supply Description
•
Four-Input 240-A DC Power Supply on page 117
•
Four-Input 240-A DC Power Supply Inputs on page 117
•
Four-Input 240-A DC Power Supply Load Sharing and Fault Tolerance on page 118
Four-Input 240-A DC Power Supply
Each four-input 240-A DC power supply weighs approximately 26.6 lb (12.0 kg) and consists of four inputs, four 60-A circuit breakers, a fan, and LEDs to monitor the status of the power supply.
shows the four-input 240-A DC power supply.
Figure 41: Four-Input 240-A DC Power Supply
LEDs Circuit breakers
Four-Input 240-A DC Power Supply Inputs
The four-input 240-A DC power supply inputs are labeled INPUT 0 , INPUT 1 , and INPUT 2 , and INPUT 3 from top to bottom. Each input consists of –48 VDC and return, each with its own 60-A circuit breaker.
Copyright © 2019, Juniper Networks, Inc.
117
T1600 Core Router Hardware Guide
describes which components are powered by each input.
Table 71: Components Powered by Each Four-Input 240-A DC Power Supply Input
Input
INPUT 0
Components
SIBs, control boards, Routing Engines, and half the system fan power
INPUT 1
INPUT 2
INPUT 3
FPCs in slots FPC0 and FPC1 and half the system fan power
FPCs in slots FPC2 through FPC4
FPCs in slots FPC5 through FPC7
Four-Input 240-A DC Power Supply Load Sharing and Fault Tolerance
When the router is operating normally and both power supplies are switched on, load sharing between them occurs automatically. When one power supply fails or is turned off, the other power supply immediately assumes the entire electrical load for the system.
A single power supply can provide full power for as long as the router is operational. If any of the four inputs fails, the router shuts down, and the other power supply assumes the electrical load for all four inputs.
Related
Documentation
•
T1600 Power System Description on page 113
•
T1600 Four-Input 240-A DC Power Supply LEDs on page 118
•
Maintaining the T1600 Power Supplies on page 525
•
Troubleshooting the T1600 Power System on page 552
•
T1600 DC Power Requirements on page 148
T1600 Four-Input 240-A DC Power Supply LEDs
LEDs on each four-input 240-A DC power supply faceplate (see
) indicate the status of the power supply. In addition, a power supply failure triggers the red alarm LED on the craft interface.
displays the power supply
LEDs.
Figure 42: Four-Input 240-A DC Power Supply LEDs
CIRCUIT BREAKERS FOR MIN. 60
SEC. TO DE-ENERGIZE THE UNIT
COMPLETELY BEFORE TURN ON.
60A
60A
60A
INPUT 3
60A
Power supply LEDs
118 Copyright © 2019, Juniper Networks, Inc.
Chapter 7: Power System Components and Descriptions
Table 72: Four-Input 240-A DC Power Supply LEDs
LED Color State
INPUT
PRESENT —One per input
Green
CB ON —One per input
Green
On steadily
Off
On steadily
Off
DC OK —One per power supply
Blue
OVER
TEMP —One per power supply
Yellow
On steadily
Blinking
On steadily
Off
Description
Input is receiving voltage.
Input voltage is not present.
Circuit breaker is on.
Circuit breaker is not turned on, or host subsystem has detected a failure and has turned the circuit breaker off.
When all four inputs are properly energized, the DC OK LED indicates that the power supply is functioning normally.
Either the power supply is starting up, or it is not functioning, not properly installed, or not operating properly.
Power supply has exceeded recommended temperature.
Power supply is within the recommended temperature or the power supply is not on.
Related
Documentation
•
T1600 Four-Input 240-A DC Power Supply Description on page 117
•
T1600 DC Power Requirements on page 148
•
Maintaining the T1600 Power Supplies on page 525
•
Troubleshooting the T1600 Power System on page 552
T1600 Six-Input DC Power Supply Description
•
Power Supply Components on page 119
•
•
Power Supply Components
Each six-input DC power supply weighs approximately 39.7 lb (18.0 kg) and consists of six inputs, two blowers, a front and side air filter, and LEDs to monitor the status of the power supply. Each power supply is cooled by its own internal cooling system.
shows the six-input DC power supply.
Copyright © 2019, Juniper Networks, Inc.
119
T1600 Core Router Hardware Guide
NOTE: There are no circuit breakers or passive fuses in the router.
Figure 43: Six-Input DC Power Supply
Inputs
The six-input DC power supply inputs are labeled INPUT 0 , INPUT 1 , INPUT 2 , INPUT 3 ,
INPUT 4 , and INPUT 5 , from top to bottom. Each 60 A input consists of –48 VDC and return.
describes which components are powered by each input.
Table 73: Components Powered by Each Six-Input DC Power Supply Input
Input Components
INPUT 0
INPUT 1 through INPUT 5
Fan trays
FPCs, Routing Engines, control boards, SIBs, craft interface, SCGs, and other components in the router.
Redundancy
When the router is operating normally and both power supplies are switched on, load sharing between them occurs automatically. When one power supply fails or is turned off, the other power supply immediately assumes the entire electrical load for the system.
A single power supply can provide full power for as long as the router is operational.
Related
Documentation
•
T1600 Power System Description on page 113
•
T1600 Six-Input DC Power Supply LEDs on page 121
•
Maintaining the T1600 Power Supplies on page 525
•
Troubleshooting the T1600 Power System on page 552
•
T1600 DC Power Requirements on page 148
120 Copyright © 2019, Juniper Networks, Inc.
Chapter 7: Power System Components and Descriptions
T1600 Six-Input DC Power Supply LEDs
LEDs on each six-input DC power supply faceplate indicate the status of the power supply. In addition, a power supply failure triggers the red alarm LED on the craft interface.
displays the power supply LEDs.
Table 74: Six-Input DC Power Supply LEDs
LED Color State Description
INPUT
PRESENT —One per input
Green
DC OK —One per power supply
Blue
On steadily
Off
On steadily
Input is receiving voltage.
Input voltage is not present.
When all inputs are properly energized, the DC OK LED indicates that the power supply is functioning normally.
OVER
TEMP —One per power supply
Yellow
Blinking
On steadily
Off
Either the power supply is starting up, or it is not functioning, not properly installed, or not operating properly.
Power supply has exceeded recommended temperature.
Power supply is within the recommended temperature or the power supply is not on.
Related
Documentation
•
T1600 Six-Input DC Power Supply Description on page 119
•
T1600 DC Power Requirements on page 148
•
Maintaining the T1600 Power Supplies on page 525
•
Troubleshooting the T1600 Power System on page 552
T1600 Three-Phase Delta and Wye AC Power Supply Description
•
Three-Phase Delta AC Power Supply on page 121
•
Three-Phase Wye AC Power Supply on page 123
•
AC Power Supply Load Sharing and Fault Tolerance on page 124
Three-Phase Delta AC Power Supply
Each three-phase delta AC power supply weighs approximately 31.0 lb (14.06 kg). A metal wiring compartment contains the AC terminal block and ground labeled GND . The
AC terminal block consists of three input terminals labeled L1 , L2 , and L3 , from left to right. The power switch provides power to the router. Each power supply’s cooling system
Copyright © 2019, Juniper Networks, Inc.
121
T1600 Core Router Hardware Guide consists of two fans, a front air filter, and a side air filter. LEDs provide the status of the power supply.
shows the three-phase delta AC power supply.
Figure 44: Three-Phase Delta AC Power Supply
shows the three-phase delta AC power supply connections.
Figure 45: Three-Phase Delta AC Power Supply Connections
L1 L2 L3
L1 L2 L3
122
shows the three-phase delta AC power cord.
Copyright © 2019, Juniper Networks, Inc.
Chapter 7: Power System Components and Descriptions
Figure 46: Three-Phase Delta AC Power Cord
Three-Phase Wye AC Power Supply
Each three-phase wye AC power supply weighs approximately 31.0 lb (14.06 kg). A metal wiring compartment contains the AC terminal block and ground labeled GND . The AC terminal block consists of four input terminals labeled L1 , L2 , L3 , and N , from left to right.
The power switch provides power to the router. Each power supply’s cooling system consists of two fans, a front air filter, and a side air filter. LEDs provide the status of the power supply.
shows the three-phase wye AC power supply.
Figure 47: Three-Phase Wye AC Power Supply
shows the three-phase wye AC power supply connections.
Copyright © 2019, Juniper Networks, Inc.
123
T1600 Core Router Hardware Guide
Figure 48: Three-Phase Wye AC Power Supply Connections
L1 L2 L3 N
shows the three-phase wye AC power cord.
Figure 49: Wye Three-Phase AC Power Cord
AC Power Supply Load Sharing and Fault Tolerance
When the router is operating normally and both power supplies are switched on, load sharing between them occurs automatically. When one power supply fails or is turned off, the other power supply immediately assumes the entire electrical load for the system.
A single power supply can provide full power for as long as the router is operational.
Related
Documentation
•
T1600 Power System Description on page 113
•
T1600 Three-Phase Delta and Wye AC Power Supply LEDs on page 124
•
Maintaining the T1600 Power Supplies on page 525
•
Troubleshooting the T1600 Power System on page 552
•
T1600 AC Power Requirements on page 157
•
T1600 AC Power Cord Specifications on page 159
T1600 Three-Phase Delta and Wye AC Power Supply LEDs
shows the LEDs on each three-phase delta AC power supply faceplate. The three-phase wye AC power supply has the same LEDs. The LEDs in
124 Copyright © 2019, Juniper Networks, Inc.
Chapter 7: Power System Components and Descriptions
indicate the status of the power supply. In addition, a power supply failure triggers the red alarm LED on the craft interface.
Figure 50: Delta AC Power Supply LEDs
AC
OK
DC
OK
OVER
TEMP
L1 L2 L3
Table 75: Delta AC Power Supply LEDs
LED Color State
On steadily AC OK —One per power supply
Green
– Off
DC OK —One per power supply
Blue
–
On steadily
Blinking
Off
Power supply LEDs
Description
The AC terminal block is receiving voltage.
The AC terminal block is not receiving voltage.
Power supply is functioning normally.
Power supply is starting up, or is not functioning or operating properly, or is not properly installed.
The power supply fails or the AC terminal block is not receiving voltage.
OVER
TEMP —One per power supply
Yellow
–
On steadily
Off
Power supply has exceeded recommended temperature.
If the DC OK and AC OK are on steadily, this LED indicates that power supply is within the recommended temperature.
Related
Documentation
•
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
Maintaining the T1600 Power Supplies on page 525
•
Troubleshooting the T1600 Power System on page 552
•
T1600 AC Power Requirements on page 157
Copyright © 2019, Juniper Networks, Inc.
125
T1600 Core Router Hardware Guide
126 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 8
Switch Fabric Components and
Descriptions
•
T1600 Switch Interface Board (SIB) Description on page 127
•
T1600-SIB Description on page 128
•
•
TXP-T1600 SIB Description on page 129
•
TXP-T1600 SIB LEDs on page 130
•
T1600 TXP-LCC-3D SIB Description on page 131
•
T1600 TXP-LCC-3D SIB LEDs on page 132
T1600 Switch Interface Board (SIB) Description
SIBs create the switch fabric for the T1600 Core Router. Each T1600 router contains five
SIBs located at the center rear of the chassis in the slots labeled SIB0 through SIB4 (top to bottom). One of the five SIBs acts as a backup to the remaining four SIBs. If a SIB fails, the backup SIB becomes active, and traffic forwarding continues without any degradation.
When the failed SIB is replaced, it becomes the new backup. SIBs are hot-insertable and hot-removable.
The T1600 router supports the SIBs listed in
Table 76: T1600 Supported SIBs
Name Model Number
First Supported
Junos OS
Release
T1600-SIB
NOTE: The T1600-SIB is required for a standalone
T1600 router.
SIB-T1600 8.5
TXP-T1600
NOTE: The TXP-T1600 SIB is required for connection to a TX Matrix Plus router with the TXP-T1600 configuration.
SIB-TXP-T1600 9.6R2
Copyright © 2019, Juniper Networks, Inc.
127
T1600 Core Router Hardware Guide
Table 76: T1600 Supported SIBs (continued)
Name Model Number
TXP-LCC-3D
NOTE: The TXP-LCC-3D SIB is required for connection to a TX Matrix Plus router with the TXP-T1600-3D,
TXP-T4000-3D, and TXP-Mixed-LCC-3D configurations.
SIB-TXP-3D-LCC
First Supported
Junos OS
Release
13.1
Related
Documentation
•
T1600-SIB Description on page 128
•
TXP-T1600 SIB Description on page 129
•
T1600 TXP-LCC-3D SIB Description on page 131
•
T1600 Router Description on page 3
T1600-SIB Description
shows a T1600-SIB. T1600-SIBs are supported only on standalone
T1600 routers. A T1600 router in a routing matrix does not support T1600-SIBs.
Figure 51: T1600-SIB
128
Each T1600-SIB consists of the following components:
• Switch fabric ASICs.
• High-speed links to each FPC.
• SIB online/offline button, located on the SIB faceplate.
• Three LEDs— ACTIVE , OK , and FAIL —located on the SIB faceplate that display the status of the T1600-SIB. The OK and FAIL LEDs are replicated on the craft interface.
Related
Documentation
•
T1600 Switch Interface Board (SIB) Description on page 127
Copyright © 2019, Juniper Networks, Inc.
Chapter 8: Switch Fabric Components and Descriptions
•
•
Maintaining the T1600 SIBs on page 531
•
Troubleshooting the T1600 SIBs on page 557
T1600-SIB LEDs
describes the functions of the T1600-SIB LEDs. If all three LEDs are off, the SIB is not receiving power. The craft interface has three additional LEDs that show the status of each SIB.
Table 77: T1600–SIB LEDs
Label Color State Description
ACTIVE
OK
Green
Green
On steadily SIB is in active mode.
On steadily SIB is functioning normally.
FAIL Yellow
Blinking SIB is starting up.
On steadily SIB has failed.
Related
Documentation
•
T1600 Switch Interface Board (SIB) Description on page 127
•
T1600-SIB Description on page 128
•
Maintaining the T1600 SIBs on page 531
•
Troubleshooting the T1600 SIBs on page 557
TXP-T1600 SIB Description
shows a TXP-T1600 SIB. A T1600 router in a routing matrix requires
TXP-T1600 SIBs. Each TXP-T1600 SIB weighs 10.2 lb (4.6 kg).
Figure 52: TXP-T1600 SIB
Each TXP-T1600 SIB consists of the following components:
• Switch fabric ASICs.
• High-speed links to each FPC.
Copyright © 2019, Juniper Networks, Inc.
129
T1600 Core Router Hardware Guide
• SIB online/offline button, located on the SIB faceplate.
• Three LEDs located on the SIB faceplate that display the status of the T1600-SIB. The
OK and FAIL LEDs are replicated on the craft interface.
Related
Documentation
•
T1600 Switch Interface Board (SIB) Description on page 127
•
TXP-T1600 SIB LEDs on page 130
•
Maintaining the T1600 SIBs on page 531
•
Troubleshooting the T1600 SIBs on page 557
TXP-T1600 SIB LEDs
describes the functions of the T1600-SIB LEDs. If all three LEDs are off, the SIB is not receiving power. The craft interface has three additional LEDs that show the status of each SIB.
Table 78: TXP-T1600 SIB LEDs
Label Color State Description
ACTIVE
OK
Green
Green
On steadily SIB is in active mode.
On steadily SIB is functioning normally.
Blinking SIB is starting up.
FAIL Yellow On steadily SIB has failed.
The port LEDs—labeled A , B , C , D —are located in the upper left corner of the TXP-T1600
SIB.
shows the port LEDs.
describes the functions of these LEDs.
Figure 53: TXP-T1600 SIB Port LEDs
130 Copyright © 2019, Juniper Networks, Inc.
Chapter 8: Switch Fabric Components and Descriptions
Table 79: TXP-T1600 SIB Port LEDs
Label Color State
LINK Green On steadily
Yellow
Blinking
On steadily
Blinking
Red On steadily
RxPWR
–
Green
Yellow
–
Off
On steadily
On steadily
Off
Description
The link between the TXP-F13 SIB port and the TXP-T1600 SIB port has been established successfully.
The link between the TXP-T1600 SIB port and the loopback connector has been established successfully.
The link is being established.
The fiber-optic array cable might be connected to either the wrong TXP-T1600 SIB port or wrong TXP-FI3 port.
The link between the TXP-F13 SIB port and the TXP-T1600 SIB port failed. There might be a hardware problem, or the fiber-optic port or cable might need to be cleaned.
The cable is not connected on both sides, or either the TXP-F13
SIB or TXP-T1600 SIB is powered off.
Full optical power is being received.
Diminished optical power is being received. The fiber-optic array cable or the fiber-optic array port might need cleaning, or the cable might be damaged.
No optical power has been received. The fiber-optic array cable is not connected to the TXP-FI3 SIB port, or not connected to the TXP-T1600 SIB port. If the cable is connected on both sides, the cable might be cut.
Related
Documentation
•
T1600 Switch Interface Board (SIB) Description on page 127
•
TXP-T1600 SIB Description on page 129
•
Maintaining the T1600 SIBs on page 531
•
Troubleshooting the T1600 SIBs on page 557
T1600 TXP-LCC-3D SIB Description
shows a TXP-LCC-3D SIB (model number SIB-TXP-3D-LCC) that is required to connect a T1600 line card chassis (LCC) to TXP-F13-3D SIBs in a TX Matrix
Plus Router.
Copyright © 2019, Juniper Networks, Inc.
131
T1600 Core Router Hardware Guide
Figure 54: TXP-LCC-3D SIB
SIB status
LEDs
ONLINE/
OFFLINE button
ONLINE/
OFFLINE
OK
FAIL
ACTIVE
Ports: 0 1 2 3 4 5 6 7 Port LEDs
Each TXP-LCC-3D SIB consists of the following components:
• Eight ports labeled 0 through 7 . Each port has a CBL and LINK LED.
• Switch fabric ASICs.
• High-speed links to each FPC.
• SIB online/offline button, located on the SIB faceplate. The button is to signal a removal request by a user.
• Three LEDs— OK , FAIL , and ACTIVE —located on the SIB faceplate that display the status of the TXP-LCC-3D SIB. The OK and FAIL LEDs are replicated on the craft interface.
Related
Documentation
•
T1600 Switch Interface Board (SIB) Description on page 127
•
T1600 TXP-LCC-3D SIB LEDs on page 132
•
Maintaining the T1600 SIBs on page 531
•
Replacing a T1600 TXP-LCC-3D SIB on page 487
•
Troubleshooting the T1600 SIBs on page 557
T1600 TXP-LCC-3D SIB LEDs
describes the functions of the TXP-LCC-3D SIB LEDs (see
). If all three LEDs are off, the SIB is not receiving power. The craft interface has three additional LEDs that show the status of each SIB.
132 Copyright © 2019, Juniper Networks, Inc.
Chapter 8: Switch Fabric Components and Descriptions
Figure 55: TXP-3D-LCC SIB LEDs
OK
FAIL
ACTIVE
OK
FAIL
ACTIVE
ONLINE/
OFFLINE
Table 80: TXP-LCC-3D SIB LEDs
Label Color State
ACTIVE
OK
FAIL
Green
Green
Red
On steadily
Off
On steadily
Blinking
Off
On steadily
Off
Description
SIB is in active mode.
SIB is in standby mode.
NOTE: This LED has significance only if the ONLINE LED is lit.
SIB is functioning normally.
SIB is starting up.
SIB has been inserted or is ready for removal.
SIB has failed.
SIB is functioning normally.
The TXP-LCC-3D SIB port LEDs are located beneath each port. Each port has a Link and
CBL LED.
describes the functions of these LEDs.
Copyright © 2019, Juniper Networks, Inc.
133
T1600 Core Router Hardware Guide
Table 81: TXP-LCC-3D SIB Port LEDs
Label Color State
LINK Green On steadily
Yellow
Red
–
CBL Green
Yellow
Red
Off
Blinking
On steadily
Blinking
On steadily
Off
On steadily
On steadily
Off
–
Description
The link between the TXP-F13-3D SIB port and the TXP-LCC-3D SIB port has been established successfully.
The link between the TXP-LCC-3D SIB port and the loopback connector has been established successfully.
The link is being established.
The switching plane cable might be connected to either the wrong TXP-LCC-3D
SIB port or the wrong TXP-FI3-3D port.
The link between the TXP-F13-3D SIB port and the TXP-LCC-3D SIB port failed.
There might be a hardware problem, or the fiber-optic port or cable might need to be cleaned.
The cable is not connected on both sides, or either the TXP-F13-3D SIB or the
TXP-LCC-3D SIB is powered off.
Full optical power is being received.
Diminished optical power is being received. The switching plane cable or the switching plane port might need cleaning, or the cable might be damaged.
Optical power has crossed operating thresholds. The switching plane cable is not connected to the TXP-FI3-3D SIB port, or is not connected to the TXP-LCC-3D
SIB port. If the cable is connected on both sides, the cable might be cut.
No optical power is detected. Cable is damaged or absent.
Related
Documentation
•
T1600 Switch Interface Board (SIB) Description on page 127
•
T1600 TXP-LCC-3D SIB Description on page 131
•
Maintaining the T1600 SIBs on page 531
•
Troubleshooting the T1600 SIBs on page 557
134 Copyright © 2019, Juniper Networks, Inc.
PART 2
Site Planning, Preparation, and
Specifications
•
Preparation Overview on page 137
•
DC Power Specifications and Requirements on page 145
•
AC Power Specifications and Requirements on page 155
•
Network Cable and Transceiver Specifications on page 163
•
Management Cable Specifications and Pinouts on page 169
Copyright © 2019, Juniper Networks, Inc.
135
T1600 Core Router Hardware Guide
136 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 9
Preparation Overview
•
T1600 Site Preparation Requirements Checklist on page 137
•
T1600 Environmental Specifications on page 138
•
T1600 Physical Specifications on page 139
•
T1600 Chassis Grounding Cable and Lug Specifications on page 140
•
Rack Requirements for the T1600 Router on page 141
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
T1600 Site Preparation Requirements Checklist
The checklist in
summarizes the tasks you need to perform when preparing a site for router installation.
Table 82: Site Preparation Checklist
Item or Task For More Information Performed By Date
Environment
Verify that environmental factors such as temperature and humidity do not exceed router tolerances.
Power
Measure distance between external power sources and router installation site.
Locate sites for connection of system grounding.
Calculate the power consumption and requirements.
“T1600 DC Power Distribution” on page 151
“T1600 Chassis Grounding Cable and
Lug Specifications” on page 140
“T1600 AC Power Requirements” on page 157
“T1600 DC Power Requirements” on page 148
Rack
Verify that your rack meets the minimum requirements for the installation of the router.
“Rack Requirements for the T1600
Copyright © 2019, Juniper Networks, Inc.
137
T1600 Core Router Hardware Guide
Table 82: Site Preparation Checklist (continued)
Item or Task For More Information
Plan rack location, including required space clearances.
“Clearance Requirements for Airflow and T1600 Hardware Maintenance” on page 143
If a rack is used, secure rack to floor and building structure.
“Rack Requirements for the T1600
Performed By
Cables and Transceivers
Acquire cables and transceivers:
•
•
Determine the number of cables needed based on your planned configuration.
Review the maximum distance allowed for each cable. Choose the length of cable based on the distance between the hardware components being connected.
Determining Transceiver Support and
Specifications for M Series and T
Series Routers
“Understanding Fiber-Optic Cable
Power Margin for Fiber-Optic Cables” on page 165
Plan the cable routing and management.
“Maintaining T1600 PICs and PIC
Date
T1600 Environmental Specifications
specifies the environmental specifications required for normal router operation. In addition, the site should be as dust-free as possible.
Table 83: Router Environmental Specifications
Description Value
Altitude
Relative humidity
Temperature
Seismic
No performance degradation to 10,000 ft (3048 m)
Normal operation ensured in relative humidity range of 5% to 90%, noncondensing
Normal operation ensured in temperature range of 32°F (0°C) to
104°F (40°C)
Nonoperating storage temperature in shipping crate: –40°F (–40°C) to 158°F (70°C)
Designed to meet Telcordia Technologies Zone 4 earthquake requirements
Maximum thermal output DC power: 28,498 BTU/hour (8350 W)
138 Copyright © 2019, Juniper Networks, Inc.
Chapter 9: Preparation Overview
NOTE: Install the router only in restricted areas, such as dedicated equipment rooms and equipment closets, in accordance with Articles 110-16, 110-17, and
110-18 of the National Electrical Code, ANSI/NFPA 70.
Related
Documentation
•
General Safety Guidelines for Juniper Networks Devices on page 585
•
T1600 Router Description on page 3
T1600 Physical Specifications
lists the T1600 router's physical specifications.
Table 84: T1600 Physical Specifications
Description Value
Chassis dimensions
Router weight
37.45 in. (95.1 cm) high
17.43 in. (44.3 cm) wide
31 in. (78.7 cm) deep
Total depth (including front cable management system)
35.5 in. (90.2 cm)
Total depth (including front cable management system and the optional rear cable management system) 45 in.
(114.3 cm)
11.5 in. (29.2 cm) from front of chassis to center-mounting brackets
Chassis with midplane: 205 lb (93 kg)
Minimum configuration: 387 lb (176 kg)
Maximum configuration: 606 lb (275 kg)
Routing Engine weight
Craft interface weight
FPC weight
CIP weight
Three-input 240-A DC power supply weight
Four-input 240-A DC power supply weight
2.4 lb (1 kg)
2 lb (1 kg)
FPCs with PICs installed: Up to 37 lb (17 kg)
FPC without PICs installed: up to 25 lb (11 kg)
Blank panel in FPC slot: 9 lb (4.0 kg)
8 lb (4 kg)
25 lb each (11 kg)
26.6 lb (12.0 kg)
Copyright © 2019, Juniper Networks, Inc.
139
T1600 Core Router Hardware Guide
Table 84: T1600 Physical Specifications (continued)
Description Value
Six-input DC power supply weight 39.7 lb (18.0 kg)
Delta AC power supply weight
Wye AC power supply weight
Air filter weight
36.0 lb (16.3 kg)
36.6 lb (16.6 kg)
1 lb (0.45 kg)
T1600-SIB weight
TXP-T1600 SIB weight
TXP-3D-LCC-SIB weight
T-CB weight
LCC-CB weight
SCG weight
Standard rear fan tray weight
Standard front fan tray weight
Quiet rear fan tray weight
Quiet front fan tray weight
6.5 lb each (3 kg)
10.2 lb each (4.6 kg)
9.4 lb each (4.2 kg)
5 lb each (2 kg)
5 lb each (2 kg)
1.9 lb each (1 kg)
10 lb (4.5 kg)
18.6 lb (8.5 kg)
10 lb (4.5 kg)
17.8 lb (8.1 kg)
FAN-R-TXP-3D-LCC rear fan tray 13 lb (5.9 kg)
FANTRAY-T4000 front fan tray
Cable management weight
20.4 lb (9.3 kg)
5 lb (2 kg)
Related
Documentation
•
T1600 Router Description on page 3
•
T1600 Chassis Description on page 21
•
T1600 Chassis Lifting Guidelines on page 595
T1600 Chassis Grounding Cable and Lug Specifications
To meet safety and electromagnetic interference (EMI) requirements and to ensure proper operation, the router must be adequately grounded before power is connected.
Two pairs of threaded inserts (PEM nuts) are provided on the right rear of the chassis for connecting the router to earth ground. The left pair of grounding points fits M6 screws
140 Copyright © 2019, Juniper Networks, Inc.
Chapter 9: Preparation Overview
(European), and the right pair fits UNC 1/4–20 screws (American). The grounding points are spaced at 0.625-in. (15.86-mm) centers.
You must supply a grounding cable. The grounding cable must be 8-AWG (8.35 mm
2
), minimum 90°C wire, or as required by the local code.
The accessory box shipped with the router includes one 4-AWG (21.2 mm
2 cable lug that attaches to the grounding cable (see
). (The cable lug shown in
is also used for the DC power cables.) The accessory box includes two UNC 1/4–20 screws used to secure the grounding cable to the right pair of grounding points.
CAUTION: Before router installation begins, a licensed electrician must attach a cable lug to the grounding cable that you supply. A cable with an incorrectly attached lug can damage the router.
Figure 56: Grounding Cable Lug
Related
Documentation
•
Connecting the T1600 Grounding Cable on page 232
•
T1600 DC Power System Electrical Specifications on page 145
Rack Requirements for the T1600 Router
The router can be installed in many types of racks, including four-post (telco) racks and open-frame racks. An example of an open-frame rack is shown in
For open-frame racks, center-mounting is preferable to front-mounting because the more even distribution of weight provides greater stability.
The router is designed for installation in a 19-in. rack as defined in Cabinets, Racks, Panels, and Associated Equipment (document number EIA-310-D) published by the Electronics
Components Industry Association ( http://www.ecianow.org/ ).
With the use of adapters, the router can fit into a 600-mm-wide rack, as defined in the four-part Equipment Engineering (EE); European Telecommunications Standard for
Equipment Practice (document numbers ETS 300 119-1 through 119-4) published by the
European Telecommunications Standards Institute ( http://www.etsi.org
). Use approved wing devices to narrow the opening between the rails.
Copyright © 2019, Juniper Networks, Inc.
141
T1600 Core Router Hardware Guide
The rack rails must be spaced widely enough to accommodate the router chassis's external dimensions: 37.45 in. (95.1 cm) high, 31 in. (78.7 cm) deep, and 17.43 in. (44.3 cm) wide, excluding the front and rear cable management systems. The outer edges of the mounting brackets extend the width to 19 in. (48.3 cm). The spacing of rails and adjacent racks must also allow for the clearances around the router and rack.
The mounting holes for connecting the mounting brackets to the chassis are spaced
0.984 in. (25 mm) apart.
The chassis height of 37.45 in. (95.1 cm) is approximately 21.4 U. A U is the standard rack unit defined in Cabinets, Racks, Panels, and Associated Equipment (document number
EIA-310-D) published by the Electronics Components Industry Association. You can stack two routers in a rack that has at least 42.8 U (74.9 in. or 1.90 m) of usable vertical space.
The rack must be strong enough to support the weight of the fully configured router, up to 606 lb (275 kg). If you stack two fully configured routers in one rack, it must be capable of supporting about 1212 lb (550 kg).
Figure 57: Typical Open-Frame Rack
142
Always secure the rack to the structure of the building. If your geographical area is subject to earthquakes, bolt the rack to the floor. For maximum stability, also secure the rack to ceiling brackets.
Copyright © 2019, Juniper Networks, Inc.
Chapter 9: Preparation Overview
Related
Documentation
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
•
Installation Safety Warnings for Juniper Networks Devices on page 595
•
T1600 Router Description on page 3
Clearance Requirements for Airflow and T1600 Hardware Maintenance
When planning the installation site, you need to allow sufficient clearance around the rack (see
• For the cooling system to function properly, the airflow around the chassis must be unrestricted.
NOTE: If you mount the router in a cabinet, be sure that ventilation is sufficient to prevent overheating.
• For service personnel to remove and install hardware components, there must be adequate space at the front and back of the router. At least 24 in. (61 cm) are required both in front of and behind the router. NEBS GR-63 recommends that you allow at least 30 in. (72.6 cm) behind the rack.
• Additional clearance is required to accommodate the width and depth of the chassis with the optional rear cable management system:
• 2.4 in. (6.2 cm) additional width on the left side of the chassis
• 9.5 in. (24.1 cm) additional depth in the rear of the chassis
Figure 58: Chassis Dimensions and Clearance Requirements
30" (76.2 cm) clearance recommended for maintenance
31 "
(78.7 cm)
30" (76.2 cm) clearance recommended for maintenance
(without rear cable management system)
Front of chassis
19.2"
(48.7 cm)
17.4"
(44.2 cm)
Rear of chassis
Front-mounting flange
Center-mounting bracket
2.4"
(6.1 cm)
19.8" (50.3 cm) width with rear cable managment system
30" (76.2 cm) clearance recommended for maintenance
(with rear cable management system)
9.5"
(24.1 cm) depth for optional rear cable managment system
Copyright © 2019, Juniper Networks, Inc.
143
T1600 Core Router Hardware Guide
Related
Documentation
•
T1600 Chassis Description on page 21
•
T1600 Rear Cable Management System Description on page 25
•
T1600 Cooling System Description on page 39
•
Rack Requirements for the T1600 Router on page 141
144 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 10
DC Power Specifications and
Requirements
•
T1600 DC Power System Electrical Specifications on page 145
•
T1600 Three-Input 240-A DC Power Supply Specifications on page 146
•
T1600 Four-Input 240-A DC Power Supply Specifications on page 147
•
T1600 Six-Input DC Power Supply Specifications on page 148
•
T1600 DC Power Requirements on page 148
•
T1600 DC Power Distribution on page 151
•
T1600 DC Power Cables and Lugs on page 152
T1600 DC Power System Electrical Specifications
lists the DC power system electrical specifications.
Table 85: Power System Electrical Specifications
Item Specification
DC input voltage
DC system current rating
Operating range: –40.0 to –72.0 VDC
NOTE: If the input voltage from the DC power source drops below –37.5 to –39.5 VDC, the routing platform automatically shuts down.
During automatic shutdown, the circuit remains active. When the input voltage returns to –43.0
to –44.0 VDC, the router automatically starts up again and the system returns to normal operation within 30 minutes. No operator intervention is required.
174 A @ –48 VDC (nominal) (8350 W)
For each three-input 240-A DC power supply, we recommend that you provision at least
67 A @ –48 VDC per input. Although Input 0 in the three-input 240-A DC power supply requires less power, we recommend provisioning the same amount of power for each input to avoid the possibility of connecting the lower-powered DC cable to Input 1 or Input
2 .
Copyright © 2019, Juniper Networks, Inc.
145
T1600 Core Router Hardware Guide
For each four-input 240-A power supply, we recommend that you provision at least 50 A
@ –48 VDC per input . Although Input 0 and Input 1 in the four-input 240-A power supply require less power, we recommend provisioning the same amount of power for each input to avoid the possibility of connecting the lower-powered DC cables to Input 2 or
Input 3 .
For each six-input DC power supply, we recommend that you provision at least 56 A @
–48 VDC per input . Although Input 0 in the six-input DC power supply requires less power, we recommend provisioning the same amount of power for each input to avoid the possibility of connecting the lower-powered DC cables to Input 1 through Input 5 .
You must provision a circuit breaker for each DC power supply input rated for at least
125% of the continuous current that the system draws at –48 VDC.
Related
Documentation
•
T1600 Power System Description on page 113
•
Connecting DC Power to the T1600 Router (Three-Input 240-A DC Power Supplies or
Four-Input 240-A DC Power Supplies) on page 246
•
T1600 Site Preparation Requirements Checklist on page 137
T1600 Three-Input 240-A DC Power Supply Specifications
lists the three-input 240-A DC power supply electrical specifications.
Table 86: Power Supply Electrical Specifications
Item Specification
DC input voltage Nominal –48 VDC, –60 VDC
Operating range: –40.0 to –72.0 VDC
NOTE: If the input voltage from the DC power source drops below -37.5 to -39.5 VDC, the routing platform automatically shuts down.
During automatic shutdown, the circuit remains active. When the input voltage returns to –43.0
to –44.00 VDC, the router automatically starts up again and the system returns to normal operation within 30 minutes. No operator intervention is required.
146 Copyright © 2019, Juniper Networks, Inc.
Chapter 10: DC Power Specifications and Requirements
Table 86: Power Supply Electrical Specifications (continued)
Item Specification
Input DC current rating Part number:
• Input 0: 47 A @ –48 VDC (nominal) (2256
W)
•
•
Input 1: 67 A @ –48 VDC (nominal) (3216 W)
Input 2: 67 A @ –48 VDC (nominal) (3216
W)
Part number:
• Input 0: 54 A @ –48 VDC (nominal) (2592
W)
•
•
Input 1: 67 A @ –48 VDC (nominal) (3216 W)
Input 2: 67 A @ –48 VDC (nominal) (3216
W)
Related
Documentation
•
T1600 Power System Description on page 113
•
T1600 Three-Input 240-A DC Power Supply Description on page 114
•
T1600 DC Power System Electrical Specifications on page 145
T1600 Four-Input 240-A DC Power Supply Specifications
lists the four-input 240-A DC power supply electrical specifications.
Table 87: Four-Input 240-A DC Power Supply Electrical Specifications
Item Specification
DC input voltage
Input DC current rating
Nominal –48 VDC, –60 VDC
Operating range: –40.0 to –72.0 VDC
NOTE: If the input voltage from the DC power source drops below -37.5 to -39.5 VDC, the router automatically shuts down. During automatic shutdown, the circuit remains active.
When the input voltage returns to –43.0 to
–44.00 VDC, the router automatically starts up again and the system returns to normal operation within 30 minutes. No operator intervention is required.
Input 0: 47 A @ –48 VDC (nominal) (2256 W)
Input 1: 44 A @ –48 VDC (nominal) (2112 W)
Input 2: 50 A @ –48 VDC (nominal) (2400 W)
Input 3: 50 A @ –48 VDC (nominal) (2400 W)
Copyright © 2019, Juniper Networks, Inc.
147
T1600 Core Router Hardware Guide
Related
Documentation
•
T1600 Power System Description on page 113
•
T1600 Four-Input 240-A DC Power Supply Description on page 117
•
T1600 DC Power System Electrical Specifications on page 145
T1600 Six-Input DC Power Supply Specifications
lists the six-input DC power supply electrical specifications.
Table 88: Six-Input DC Power Supply Electrical Specifications
Item Specification
DC input voltage
Input DC current rating
Nominal –48 VDC, –60 VDC
Operating range: –40.0 to –72.0 VDC
NOTE: If the input voltage from the DC power source drops below -37.5 to -39.5 VDC, the router automatically shuts down.
During automatic shutdown, the circuit remains active. When the input voltage returns to –43.0 to –44.00 VDC, the router automatically starts up again and the system returns to normal operation within 30 minutes. No operator intervention is required.
Input 0: 45 A @ –48 VDC (nominal) (2160 W)
Input 1: 56 A @ –48 VDC (nominal) (2448 W)
Input 2: 56 A @ –48 VDC (nominal) (2448 W)
Input 3: 56 A @ –48 VDC (nominal) (2448 W)
Input 4: 56 A @ –48 VDC (nominal) (2448 W)
Input 5: 56 A @ –48 VDC (nominal) (2448 W)
Related
Documentation
•
T1600 Power System Description on page 113
•
T1600 DC Power System Electrical Specifications on page 145
T1600 DC Power Requirements
To allow for future growth so that you can operate the router in any hardware configuration without upgrading the power infrastructure, we recommend that you provision the following for each power supply.
NOTE: Although the power requirements for each input varies, we recommend that you provision the same amount of power for each input, or DC power cable when using terminal jumpers.
• Three-input 240-A DC power supply: 67 A @ –48 VDC per input
148 Copyright © 2019, Juniper Networks, Inc.
Chapter 10: DC Power Specifications and Requirements
• Four-input 240-A power supply: 50 A @ –48 VDC per input
• Six-input power supply: 56 A @ –48 VDC per input
lists the power requirements for various hardware components. For
PIC power requirements, see the T1600 Core Router Interface Module Reference .
You can use the information in
and the T1600 Core Router Interface
Module Reference to calculate power consumption for various hardware configurations, input current from a different source voltage, and thermal output, as shown in the following examples for a DC-powered router.
Table 89: Typical DC Power Requirements for T1600 Components
Component
Current
Requirement
(Amps @
–48 VDC)
Base system, not including FPCs and PICs (includes five T1600-SIBs, one host subsystem, one SCG, two three-input 240-A power supplies or two four-input 240-A power supplies, cooling system at normal speed, and craft interface)
30.9 A
Base system, not including FPCs and PICs (includes five TXP-LCC-3D SIBs, one host subsystem, one SCG, two six-input power supplies, cooling system with FAN-R-TXP-3D-LCC rear fan tray at normal speed, and craft interface)
31.1 A
T1600-SIB
TXP-1600 SIB
TXP-LCC-3D SIB
Enhanced II FPC1
Enhanced Scaling FPC1
FPC2 and Enhanced II FPC2
FPC3, Enhanced FPC3, and Enhanced II FPC3
Enhanced Scaling FPC3
T640 Enhanced Scaling FPC4
T1600 Enhanced Scaling FPC4
Host subsystem (600, 1600, or 2000 Routing Engine and T-CB)
Line-card chassis control board (LCC-CB)
C1800 Routing Engine
6.8 A
9.11 A
8.2 A
11.3 A
2.6 A
1.0 A
1.7 A
3.6 A
4.1 A
4.2 A
3.4 A
7.1 A
3.4 A
Copyright © 2019, Juniper Networks, Inc.
149
T1600 Core Router Hardware Guide
150
Table 89: Typical DC Power Requirements for T1600 Components (continued)
Component
Current
Requirement
(Amps @
–48 VDC)
SCG
Redundant backup 3-input 240 A DC power supply
0.2 A
1.7 A
Redundant backup 4-input 240 A DC power supply
Redundant backup 6-input DC power supply
Cooling system (normal speed)
Cooling system (full speed)
Cooling system with FAN-R-TXP-3D-LCC rear fan tray (normal speed)
Cooling system with FAN-R-TXP-3D-LCC rear fan tray (full speed)
Craft interface
PIC—Generalized typical value
PIC—Generalized maximum value
1.7 A
5.2 A
6.7 A
22 A
7.95 A
25.1 A
0.2 A
0.625 A
3.3 A
• Example of calculating power consumption for a minimum configuration:
Base System + 1 Type 3 FPC + 1 PIC =
30.9 A + 6.8 A + 0.625 A = 38.33 A @ –48 VDC = 1,840 W
• Example of calculating power consumption for a maximum configuration using
TXP-T1600 SIBs:
Base System + 8 T1600-Type 4 FPCs + 1 LCC-CB + 1 RE-C1800 + 1 SCG + 16 PICs + 5
(TXP-T1600 SIBs – T1600 SIBs) =
30.9 A + 8 (11.3 A) + 1.0 A + 1.7 A + + 0.2 A + 16 (3.3 A) + 5(0.5) A=
30.9 A + 90.4 A + 1.0 A + 1.7 A + + 0.2 A + 52.8 A + 2.5 A= 179.5 A @ –48 VDC = 8616 W
• Current requirement adjustment for fans running at full speed (high temperature environment or cooling component failure):
Calculated system current (X) – Cooling (normal) + Cooling (full speed) =
X A – 6.7 A + 22 A = X A + 15.3 A
• Input current from a DC source other than –48 VDC (based on maximum configuration):
(–54 VDC input) x (input current X) = (–48 VDC) x (input current Y)
54 x X = 48 x 94.1 A
Copyright © 2019, Juniper Networks, Inc.
Chapter 10: DC Power Specifications and Requirements
X = 48 x 94.1 A/54 = 83.6 A
• Typical system thermal output for maximum configuration:
Watts DC/0.293 = BTU/hr
8616/0.293 = 29,406 BTU/hr
Related
Documentation
•
T1600 Power System Description on page 113
•
T1600 Site Preparation Requirements Checklist on page 137
•
T1600 DC Power Distribution on page 151
•
T1600 DC Power System Electrical Specifications on page 145
T1600 DC Power Distribution
Most sites distribute DC power through a main conduit that leads to frame-mounted DC power distribution panels, one of which might be located at the top of the rack that houses the router. A pair of cables (one input and one return) connects each set of terminal studs to the power distribution panel.
NOTE: All inputs on the DC power supply in slot PEM0 must be powered by dedicated power feeds derived from feed A, and all inputs on the DC power supply in slot PEM 1 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed A/B feed redundancy for the system.
shows a typical DC source cabling arrangement.
Figure 59: Typical DC Source Cabling to the Router
Copyright © 2019, Juniper Networks, Inc.
151
T1600 Core Router Hardware Guide
Related
Documentation
•
T1600 General Electrical Safety Guidelines on page 613
•
T1600 Power System Description on page 113
T1600 DC Power Cables and Lugs
•
•
DC Power Cables
summarizes the specifications for the power cables, which you must supply.
Table 90: Power Cable Specifications
Quantity and Specification
Three-input 240-A DC power supplies: Twelve 4-AWG (21.2 mm
2
), minimum 90°C wire, or as required by the local code
Four-input 240-A DC power supplies: Sixteen 4-AWG (21.2 mm
2
), minimum 90°C wire, or as required by the local code
Six-input DC power supplies:
•
•
•
Six inputs: 24 4-AWG (21.2 mm
2
), minimum 90°C wire, or as required by the local code
Five inputs: 20 4-AWG (21.2 mm
2
), minimum 90°C wire, or as required by the local code
Six inputs: Sixteen 4-AWG (21.2 mm
2
), minimum 90°C wire, or as required by the local code
Table 91: Number of Cables Required
Power Supply
Three-input 240-A DC power supply
Four-input 240-A DC power supply
Six-input DC power supply: 6 inputs connected
Six-input DC power supply: 5 inputs connected
Six-input DC power supply: 5 inputs connected
Six-input DC power supply: 4 inputs connected
10
8
12
10
Number of DC Cables per Power Supply
6
8
WARNING: For field-wiring connections, use copper conductors only.
152 Copyright © 2019, Juniper Networks, Inc.
Chapter 10: DC Power Specifications and Requirements
CAUTION: Power cables must not block access to router components or drape where people could trip on them.
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
DC Power Lugs
The accessory box shipped with the T640 router includes eighteen 4-AWG (21.2 mm
2
) cable lugs for the DC cables that attach to the terminal studs of each power supply (see
). the number of DC cables and cable lugs required varies depending on the power supply (see
Table 91 on page 152 ). Each DC power cable requires one cable
lug. One cable lug is also used for grounding the chassis. The cable lugs are dual hole, and sized to fit 1/4-20 UNC terminal studs at 15.86-mm (0.625-in.) center line.
Figure 60: DC Power Cable Lug
CAUTION: Before router installation begins, a licensed electrician must attach a cable lug to the power cables that you supply. A cable with an incorrectly attached lug can damage the router.
Related
Documentation
•
T1600 Power System Description on page 113
•
Connecting DC Power to the T1600 Router (Three-Input 240-A DC Power Supplies or
Four-Input 240-A DC Power Supplies) on page 246
•
•
Connecting DC Power to the T1600 Router (Six 60-A Inputs to Six-Input DC Power
•
Connecting DC Power to the T1600 Router (Five 60-A Inputs to Six-Input DC Power
•
Replacing a T1600 DC Power Supply Cable on a Six-Input DC Power Supply on page 446
Copyright © 2019, Juniper Networks, Inc.
153
T1600 Core Router Hardware Guide
•
T1600 General Electrical Safety Guidelines on page 613
154 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 11
AC Power Specifications and
Requirements
•
T1600 AC Power System Specifications on page 155
•
T1600 Three-Phase Delta AC Power Supply Specifications on page 156
•
T1600 Three-Phase Wye AC Power Supply Specifications on page 156
•
T1600 AC Power Requirements on page 157
•
T1600 AC Power Cord Specifications on page 159
T1600 AC Power System Specifications
lists the AC power system electrical specifications.
Table 92: T1600 AC Power System Electrical Specifications
Item Specification
AC input voltage
AC input line frequency
AC system current rating
AC system input power
Delta operating range: 200 – 240 VAC (line-to-line) (nominal)
Wye operating range: 346 – 415 VAC (line-to-line) (nominal)
Delta: 60 Hz (nominal)
Wye: 50 Hz (nominal)
Delta: 34 A @ 200 VAC (line-to-line)
Wye: 20 A @ 346 VAC (line-to-line)
Delta: 11,765 W
Wye: 11,765 W
Related
Documentation
•
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
T1600 Three-Phase Delta AC Power Supply Specifications on page 156
•
T1600 Three-Phase Wye AC Power Supply Specifications on page 156
• T1600 AC Power Electrical Safety Guidelines
Copyright © 2019, Juniper Networks, Inc.
155
T1600 Core Router Hardware Guide
T1600 Three-Phase Delta AC Power Supply Specifications
lists the three-phase delta AC power supply electrical specifications.
Table 93: Three-Phase Delta AC Power Supply Electrical Specifications
Item Specification
Maximum output power
AC input voltage
10,000 W
Operating range: 200 – 240 VAC (line-to-line) (nominal)
AC input line frequency
AC input current rating
Maximum input
60 Hz (nominal)
28.3 A @ 240 VAC maximum (line-to-line)
11,765 W per input
Related
Documentation
•
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
Connecting AC Power to a T1600 Router with Three-Phase Delta AC Power Supplies on page 259
• T1600 AC Power Electrical Safety Guidelines
•
T1600 AC Power Cord Specifications on page 159
T1600 Three-Phase Wye AC Power Supply Specifications
lists the three-phase wye AC power supply electrical specifications.
Table 94: Three-Phase Wye AC Power Supply Electrical Specifications
Item Specification
Maximum output power 10,000 W
AC input voltage
AC input line frequency
AC input current rating
Maximum input
Operating range: 346 – 415 VAC (line-to-line) (nominal)
50 Hz (nominal)
16.4 A @ 415 VAC maximum (line-to-line)
11,775 W per input
Related
Documentation
•
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
Connecting AC Power to a T1600 Router with Three-Phase Wye AC Power Supplies on page 262
156 Copyright © 2019, Juniper Networks, Inc.
Chapter 11: AC Power Specifications and Requirements
• T1600 AC Power Electrical Safety Guidelines
•
T1600 AC Power Cord Specifications on page 159
T1600 AC Power Requirements
To allow for future growth so that you can operate the router in any hardware configuration without upgrading the power infrastructure, we recommend that you provision 11,765 W per each three-phase delta AC power supply or 11,775 W per each three-phase wye AC power supply.
If you do not plan to provision 11,765 W per each three-phase delta AC power supply or
11,775 W per each three-phase wye AC power supply, you can use the information in
,
, and the T1600 Core Router Interface Module
Reference to calculate power consumption for various hardware configurations, input current from a different source voltage, and thermal output, as shown in the following examples for an AC-powered router.
lists the power requirements for various hardware components when the router is operating under typical voltage conditions. For PIC power requirements, see the T1600 Core Router Interface Module Reference .
Table 95: Base AC Power Requirements
Component Power Requirement (Watts)
Base system, not including FPCs and PICs
(includes five T1600-SIBs, one host subsystem
[T-CB and 600, 1600, or 2000 Routing Engine], one SCG, cooling system at normal speed, and craft interface), and two power supplies
1774 W
Table 96: Typical AC Power Requirements for T1600 Components
Component
Power
Requirement
(Watts)
Power Requirement
(Watts) with 85%
Efficiency
T1600-SIB
TXP-1600 SIB
Enhanced II FPC1
172.8 W
196.8 W
163.2 W
203 W
232 W
192 W
Enhanced Scaling FPC1
FPC2 and Enhanced II FPC2
FPC3 and Enhanced II FPC3
Enhanced Scaling FPC3
340.8 W
163.2 W
326.4 W
437.28 W
401 W
192 W
384 W
514 W
Copyright © 2019, Juniper Networks, Inc.
157
T1600 Core Router Hardware Guide
158
Table 96: Typical AC Power Requirements for T1600 Components (continued)
Component
Power
Requirement
(Watts)
Power Requirement
(Watts) with 85%
Efficiency
T640 Enhanced Scaling FPC4 393.6 W 463 W
T1600 Enhanced Scaling FPC4
Host subsystem (600, 1600, or 2000 Routing
Engine and T-CB)
Line-card chassis control board (LCC-CB)
C1800 Routing Engine
SCG
542.4 W
124.8 W
48.0 W
81.6 W
9.6 W
Redundant backup three-phase delta AC power supply
Not applicable
Redundant backup three-phase wye AC power supply
Cooling system (full speed – normal speed)
Not applicable
1056 W —
321.6 W =
734.4 W
Craft interface
PIC—Generalized typical value
PIC—Generalized maximum value
9.6 W
30 W
158.4 W
638 W
147 W
56 W
96 W
11 W
91 W
91 W
864 W
11 W
35 W
186 W
• Example of calculating typical power consumption for minimum configuration:
Base System + 1 FPC3 + 1 PIC =
1774 W + 384 W + 35 W = 2193 W
• Example of calculating typical power consumption for maximum configuration:
Base System + 8 T1600-Type 4 FPCs + 1 LCC-CB + 1 RE-C1800 + 1 SCG + 16 PICs + 5
(TXP-T1600 SIBs – T1600 SIBs) + fan tray (full speed – normal speed) =
1774 W + 8 (638 W) + 56 W + 96 W + 11 W + 16 (186 W) + 5(232 W —203 W) + 864 W
=
1774 W + 5104 W + 56 W + 96 W +11 W + 2976 W + 145 W + 864 W + 91 W= 11,026 W
• Example of calculating system thermal output:
Watts DC/0.293 = BTU/hr
11,117/0.293 = 37.631 BTU/hr
Copyright © 2019, Juniper Networks, Inc.
Chapter 11: AC Power Specifications and Requirements
Related
Documentation
•
T1600 Power System Description on page 113
•
Connecting AC Power to a T1600 Router with Three-Phase Delta AC Power Supplies on page 259
•
Connecting AC Power to a T1600 Router with Three-Phase Wye AC Power Supplies on page 262
• T1600 AC Power Electrical Safety Guidelines
•
T1600 AC Power Cord Specifications on page 159
T1600 AC Power Cord Specifications
Most sites distribute power through a main conduit that leads to frame-mounted power distribution panels, one of which can be located at the top of the rack that houses the router. An AC power cord connects each power supply to the power distribution panel.
Each AC power supply has a metal wiring compartment that contains the AC terminal block and ground labeled GND . The wye AC terminal block consists of four input terminals labeled L1 , L2 , L3 , and N , from left to right. The delta AC terminal block consists of three input terminals labeled L1 , L2 , and L3 , from left to right.
Detachable AC power cords, each 4.5 m (approximately 14.8 ft) long, are supplied with the router. The AC power cord wires insert into the AC input terminals in the AC terminal block by screwdriver. The plug end of the power cord fits into the power source receptacle for your geographical location.
provides specifications and
and
depict the plug on the AC power cord provided for each region supported.
Table 97: Three-Phase Delta and Wye AC Power Cord Specifications
Country Model Number
Electrical
Specification Plug Type Plug Color
Europe
North America
CBL-T-PWR-STR-WYE 32 A, 400 VAC
CBL-T-PWR-STR-DELTA 60 A, 250 VAC
IEC 60309
IEC 60309
Red
Blue
Copyright © 2019, Juniper Networks, Inc.
159
T1600 Core Router Hardware Guide
Figure 61: Three-Phase Delta AC Power Cord
Figure 62: Three-Phase Wye AC Power Cord
160
NOTE: In North America, AC power cords must not exceed 4.5 m
(approximately 14.75 ft) in length, to comply with National Electrical Code
(NEC) Sections 400-8 (NFPA 75, 5-2.2) and 210-52, and Canadian Electrical
Code (CEC) Section 4-010(3). The cords supplied with the router are in compliance.
WARNING: The router is pluggable type A equipment installed in a restricted-access location. It has a separate protective earthing terminal
(sized for UNC 1/4-20 ground lugs) provided on the chassis in addition to the grounding pin of the power supply cord. This separate protective earthing terminal must be permanently connected to earth.
Copyright © 2019, Juniper Networks, Inc.
Chapter 11: AC Power Specifications and Requirements
CAUTION: Power cords and cables must not block access to device components or drape where people could trip on them.
Related
Documentation
•
Connecting AC Power to a T1600 Router with Three-Phase Delta AC Power Supplies on page 259
•
Connecting AC Power to a T1600 Router with Three-Phase Wye AC Power Supplies on page 262
•
Replacing a T1600 Three-Phase Wye AC Power Supply Cord on page 472
•
Replacing a T1600 Three-Phase Delta AC Power Supply Cord on page 459
•
T1600 Three-Phase Delta AC Power Supply Specifications on page 156
•
T1600 Three-Phase Wye AC Power Supply Specifications on page 156
Copyright © 2019, Juniper Networks, Inc.
161
T1600 Core Router Hardware Guide
162 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 12
Network Cable and Transceiver
Specifications
•
Determining Transceiver Support and Specifications for M Series and T Series
•
Understanding Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion on page 164
•
Calculating Power Budget and Power Margin for Fiber-Optic Cables on page 165
Determining Transceiver Support and Specifications for M Series and T Series Routers
You can find information about the pluggable transceivers supported on your Juniper
Networks device by using the Hardware Compatibility Tool. In addition to transceiver and connector type, the optical and cable characteristics—where applicable—are documented for each transceiver. The Hardware Compatibility Tool allows you to search by product, displaying all the transceivers supported on that device, or category, displaying all the transceivers by interface speed or type. The Hardware Compatibility Tool is located at https://apps.juniper.net/hct/ .
Some transceivers support additional monitoring using the operational mode CLI command show interfaces diagnostics optics . Use the Hardware Compatibility Tool to determine if your transceiver supports monitoring. See the Junos OS documentation for your device for a description of the monitoring fields.
CAUTION: If you face a problem running a Juniper Networks device that uses a third-party optic or cable, the Juniper Networks Technical Assistance Center
(JTAC) can help you diagnose the source of the problem. Your JTAC engineer might recommend that you check the third-party optic or cable and potentially replace it with an equivalent Juniper Networks optic or cable that is qualified for the device.
Copyright © 2019, Juniper Networks, Inc.
163
T1600 Core Router Hardware Guide
Understanding Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion
This topic describes signal loss, attenuation, and dispersion in fiber-optic cable.
•
Signal Loss in Multimode and Single-Mode Fiber-Optic Cable on page 164
•
Attenuation and Dispersion in Fiber-Optic Cable on page 164
Signal Loss in Multimode and Single-Mode Fiber-Optic Cable
Multimode fiber is large enough in diameter to allow rays of light to reflect internally
(bounce off the walls of the fiber). Interfaces with multimode optics typically use LEDs as light sources. However, LEDs are not coherent sources. They spray varying wavelengths of light into the multimode fiber, which reflects the light at different angles. Light rays travel in jagged lines through a multimode fiber, causing signal dispersion. When light traveling in the fiber core radiates into the fiber cladding, higher-order mode loss results.
Together these factors limit the transmission distance of multimode fiber compared with single-mode fiber.
Single-mode fiber is so small in diameter that rays of light can reflect internally through one layer only. Interfaces with single-mode optics use lasers as light sources. Lasers generate a single wavelength of light, which travels in a straight line through the single-mode fiber. Compared with multimode fiber, single-mode fiber has higher bandwidth and can carry signals for longer distances.
Exceeding the maximum transmission distances can result in significant signal loss, which causes unreliable transmission.
Attenuation and Dispersion in Fiber-Optic Cable
Correct functioning of an optical data link depends on modulated light reaching the receiver with enough power to be demodulated correctly.
Attenuation is the reduction in power of the light signal as it is transmitted. Attenuation is caused by passive media components, such as cables, cable splices, and connectors. Although attenuation is significantly lower for optical fiber than for other media, it still occurs in both multimode and single-mode transmission. An efficient optical data link must have enough light available to overcome attenuation.
Dispersion is the spreading of the signal over time. The following two types of dispersion can affect an optical data link:
• Chromatic dispersion—Spreading of the signal over time resulting from the different speeds of light rays.
• Modal dispersion—Spreading of the signal over time resulting from the different propagation modes in the fiber.
For multimode transmission, modal dispersion, rather than chromatic dispersion or attenuation, usually limits the maximum bit rate and link length. For single-mode transmission, modal dispersion is not a factor. However, at higher bit rates and over longer distances, chromatic dispersion rather than modal dispersion limits maximum link length.
164 Copyright © 2019, Juniper Networks, Inc.
Chapter 12: Network Cable and Transceiver Specifications
An efficient optical data link must have enough light to exceed the minimum power that the receiver requires to operate within its specifications. In addition, the total dispersion must be less than the limits specified for the type of link in Telcordia Technologies document GR-253-CORE (Section 4.3) and International Telecommunications Union
(ITU) document G.957.
When chromatic dispersion is at the maximum allowed, its effect can be considered as a power penalty in the power budget. The optical power budget must allow for the sum of component attenuation, power penalties (including those from dispersion), and a safety margin for unexpected losses.
Calculating Power Budget and Power Margin for Fiber-Optic Cables
Use the information in this topic and the specifications for your optical interface to calculate the power budget and power margin for fiber-optic cables.
TIP: You can use the Hardware Compatibility Tool to find information about the pluggable transceivers supported on your Juniper Networks device.
To calculate the power budget and power margin, perform the following tasks:
1.
Calculating Power Budget for Fiber-Optic Cable on page 165
2.
Calculating Power Margin for Fiber-Optic Cable on page 165
Calculating Power Budget for Fiber-Optic Cable
To ensure that fiber-optic connections have sufficient power for correct operation, you need to calculate the link's power budget, which is the maximum amount of power it can transmit. When you calculate the power budget, you use a worst-case analysis to provide a margin of error, even though all the parts of an actual system do not operate at the worst-case levels. To calculate the worst-case estimate of power budget (P
B you assume minimum transmitter power (P
T
) and minimum receiver sensitivity (P
R
),
):
P
B
= P
T
– P
R
The following hypothetical power budget equation uses values measured in decibels
(dB) and decibels referred to one milliwatt (dBm):
P
B
= P
T
– P
R
P
B
= –15 dBm – (–28 dBm)
P
B
= 13 dB
Calculating Power Margin for Fiber-Optic Cable
After calculating a link's power budget, you can calculate the power margin (P
M
), which represents the amount of power available after subtracting attenuation or link loss (LL) from the power budget (P
B
). A worst-case estimate of P
M assumes maximum LL:
Copyright © 2019, Juniper Networks, Inc.
165
T1600 Core Router Hardware Guide
P
M
= P
B
– LL
P
M greater than zero indicates that the power budget is sufficient to operate the receiver.
Factors that can cause link loss include higher-order mode losses, modal and chromatic dispersion, connectors, splices, and fiber attenuation.
lists an estimated amount of loss for the factors used in the following sample calculations. For information about the actual amount of signal loss caused by equipment and other factors, refer to vendor documentation.
Table 98: Estimated Values for Factors Causing Link Loss
Link-Loss Factor Estimated Link-Loss Value
Higher-order mode losses
Modal and chromatic dispersion
Single-mode—None
Multimode—0.5 dB
Single-mode—None
Multimode—None, if product of bandwidth and distance is less than 500
MHz-km
Connector
Splice
Fiber attenuation
0.5 dB
0.5 dB
Single-mode—0.5 dB/km
Multimode—1 dB/km
The following sample calculation for a 2-km-long multimode link with a power budget
(P
B
) of 13 dB uses the estimated values from
to calculate link loss
(LL) as the sum of fiber attenuation (2 km @ 1 dB/km, or 2 dB) and loss for five connectors
(0.5 dB per connector, or 2.5 dB) and two splices (0.5 dB per splice, or 1 dB) as well as higher-order mode losses (0.5 dB). The power margin (P
M
) is calculated as follows:
P
M
= P
B
– LL
P
M
= 13 dB – 2 km (1 dB/km) – 5 (0.5 dB) – 2 (0.5 dB) – 0.5 dB
P
M
= 13 dB – 2 dB – 2.5 dB – 1 dB – 0.5 dB
P
M
= 7 dB
The following sample calculation for an 8-km-long single-mode link with a power budget
(P
B
) of 13 dB uses the estimated values from
to calculate link loss
(LL) as the sum of fiber attenuation (8 km @ 0.5 dB/km, or 4 dB) and loss for seven connectors (0.5 dB per connector, or 3.5 dB). The power margin (P
M follows:
) is calculated as
P
M
= P
B
– LL
166 Copyright © 2019, Juniper Networks, Inc.
Chapter 12: Network Cable and Transceiver Specifications
P
M
= 13 dB – 8 km (0.5 dB/km) – 7(0.5 dB)
P
M
= 13 dB – 4 dB – 3.5 dB
P
M
= 5.5 dB
In both examples, the calculated power margin is greater than zero, indicating that the link has sufficient power for transmission and does not exceed the maximum receiver input power.
Copyright © 2019, Juniper Networks, Inc.
167
T1600 Core Router Hardware Guide
168 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 13
Management Cable Specifications and
Pinouts
•
T1600 Routing Engine Interface Cable and Wire Specifications on page 169
•
T1600 DB-9 Connector Pinouts for the Routing Engine AUXILIARY and CONSOLE
•
T1600 RJ-45 Connector Pinouts for the Routing Engine ETHERNET Port on page 170
T1600 Routing Engine Interface Cable and Wire Specifications
lists the specifications for the cables that connect to management ports and the wires that connect to the alarm relay contacts.
Table 99: Cable and Wire Specifications for Routing Engine Management and Alarm
Interfaces
Port Cable Specification
Cable/Wire
Supplied
Maximum
Length
Router
Receptacle
DB-9 male Routing Engine console or auxiliary interface
Routing Engine
Ethernet interface
Alarm relay contacts
RS-232 (EIA-232) serial cable
One 6-ft (1.83-m) length with
DB-9/DB-9 connectors
6 ft
(1.83 m)
Category 5 cable or equivalent suitable for
100Base-T operation
One 15-ft (4.57-m) length with
RJ-45/RJ-45 connectors
328 ft
(100 m)
Wire with gauge between 28-AWG and
14-AWG (0.08 and 2.08
mm
2
)
NO None
RJ-45 autosensing
—
Related
Documentation
•
T1600 Routing Engine Description on page 44
•
T1600 Connector Interface Panel (CIP) Description on page 27
Copyright © 2019, Juniper Networks, Inc.
169
T1600 Core Router Hardware Guide
T1600 DB-9 Connector Pinouts for the Routing Engine AUXILIARY and CONSOLE Ports
1
2
3
The ports on the CIP labeled AUXILIARY and CONSOLE are DB-9 receptacles that accept
RS-232 (EIA-232) cable. The AUXILIARY port connects the Routing Engine to a laptop, modem, or other auxiliary unit, and the CONSOLE port connects it to a management console. The ports are configured as data terminal equipment (DTE).
describes the DB-9 connector pinouts.
Table 100: DB-9 Connector Pinouts
Pin Signal Direction Description
DCD
RxD
TxD
<–
<–
–>
Carrier Detect
Receive Data
Transmit Data
6
7
4
5
8
9
DTR
Ground
DSR
RTS
CTS
RING
–>
—
<–
–>
<–
<–
Data Terminal Ready
Signal Ground
Data Set Ready
Request To Send
Clear To Send
Ring Indicator
Related
Documentation
•
T1600 Connector Interface Panel (CIP) Description on page 27
•
Connecting the T1600 Router to a Management Console or Auxiliary Device on page 237
T1600 RJ-45 Connector Pinouts for the Routing Engine ETHERNET Port
The port on the CIP labeled ETHERNET is an autosensing 10/100 millions of packets per second (Mbps) Ethernet RJ-45 receptacle that accepts an Ethernet cable for connecting the Routing Engine to a management LAN (or other device that supports out-of-band management).
describes the RJ-45 connector pinouts.
Table 101: RJ-45 Connector Pinouts
Pin Signal
1
2
TX+
TX –
170 Copyright © 2019, Juniper Networks, Inc.
Chapter 13: Management Cable Specifications and Pinouts
5
6
3
4
Table 101: RJ-45 Connector Pinouts (continued)
Pin Signal
RX+
Termination network
Termination network
RX–
7
8
Termination network
Termination network
Related
Documentation
•
T1600 Connector Interface Panel (CIP) Description on page 27
•
Connecting the T1600 Router to a Network for Out-of-Band Management on page 239
Copyright © 2019, Juniper Networks, Inc.
171
T1600 Core Router Hardware Guide
172 Copyright © 2019, Juniper Networks, Inc.
PART 3
Initial Installation and Configuration
•
T1600 Router Installation Overview on page 175
•
Unpacking the T1600 Router on page 177
•
Installing the T1600 Mounting Hardware on page 183
•
Installing the T1600 Router into a Rack on page 193
•
Installing the T1600 Router into a Rack Using a Mechanical Lift on page 195
•
Installing the T1600 Router into a Rack Without a Mechanical Lift on page 203
•
Connecting the T1600 Router to Ground on page 231
•
Connecting the T1600 Router to External Devices on page 235
•
Providing Power to the T1600 Router on page 245
•
Configuring the JUNOS Software on page 267
•
Upgrading to a T1600 Router from a T640 Router on page 275
Copyright © 2019, Juniper Networks, Inc.
173
T1600 Core Router Hardware Guide
174 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 14
T1600 Router Installation Overview
•
Overview of Installing the T1600 Router on page 175
Overview of Installing the T1600 Router
It is important to proceed through the installation process in the following order:
1.
Prepare your installation site.
See the
“T1600 Site Preparation Requirements Checklist” on page 137 .
2.
Review the safety guidelines.
See the
“General Safety Guidelines for Juniper Networks Devices” on page 585
.
3.
Unpack the router and verify the parts received.
See
“Overview of Unpacking the T1600 Router” on page 177
.
4.
Install the mounting hardware.
See
“Installing the T1600 Mounting Hardware for a Four-Post Rack or Cabinet” on page 183
or
“Installing the T1600 Mounting Hardware for an Open-Frame Rack” on page 188
.
5.
Install the router in a rack or cabinet.
See
“Overview of Installing a T1600 Router Using a Mechanical Lift” on page 195
or
“Overview of Installing a T1600 Router Without a Mechanical Lift” on page 203 .
6.
Connect the router to ground.
See
“Connecting the T1600 Grounding Cable” on page 232
.
7.
Connect the router to external devices.
See
“Overview of Connecting the T1600 Router to External Devices” on page 235
and
“Connecting PIC Cables to the T1600 Router” on page 242 .
Copyright © 2019, Juniper Networks, Inc.
175
T1600 Core Router Hardware Guide
8.
Provide power to the router.
See Overview of Providing Power to the T1600 Router
9.
Perform the initial system configuration.
See
“Initially Configuring the T1600 Router” on page 267
.
176 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 15
Unpacking the T1600 Router
•
Overview of Unpacking the T1600 Router on page 177
•
Tools and Parts Required to Unpack the T1600 Router on page 177
•
Unpacking the T1600 Router on page 178
•
Verifying the T1600 Router Parts Received on page 179
Overview of Unpacking the T1600 Router
To unpack the router:
1.
Gather the tools required to unpack the router.
See
“Tools and Parts Required to Unpack the T1600 Router” on page 177 .
2.
Unpack the router.
See
“Unpacking the T1600 Router” on page 178 .
3.
Verify that all parts have been received.
See
“Verifying the T1600 Router Parts Received” on page 179
.
Tools and Parts Required to Unpack the T1600 Router
To unpack the router and prepare for installation, you need the following tools:
• Phillips (+) screwdriver, number 2
• 1/2-in. or 13-mm open-end or socket wrench to remove bracket bolts from the shipping pallet
• Blank panels to cover any slots not occupied by a component
Related
Documentation
•
Overview of Unpacking the T1600 Router on page 177
•
Unpacking the T1600 Router on page 178
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
Copyright © 2019, Juniper Networks, Inc.
177
T1600 Core Router Hardware Guide
Unpacking the T1600 Router
The router is shipped in a wooden crate. A wooden pallet forms the base of the crate.
The router chassis is bolted to this pallet. Quick Start installation instructions and a cardboard accessory box are also included in the shipping crate.
The shipping crate measures 50 in. (127 cm) high, 30 in. (76.2 cm) wide, and 41 in. (104 cm) deep. The total weight of the crate containing the router and accessories can range from
582 lb (267 kg) to 650 lb (295 kg).
NOTE: The router is maximally protected inside the shipping crate. Do not unpack it until you are ready to begin installation.
To unpack:
1.
Move the shipping crate to a staging area as close to the installation site as possible, where you have enough room to remove the components from the chassis. While the chassis is bolted to the pallet, you can use a forklift or pallet jack to move it.
2.
Position the shipping crate with the arrows pointing up.
3.
Open all the latches on the shipping crate.
4.
Remove the front door of the shipping crate cover and set it aside.
5.
Slide the remainder of the shipping crate cover off the pallet.
6.
Remove the foam covering the top of the router.
7.
Remove the accessory box and the Quick Start documentation.
8.
Verify the parts received.
9.
Remove the vapor corrosion inhibitor (VCI) packs attached to the pallet, being careful not to break the VCI packs open.
10.
To remove the brackets holding the chassis on the pallet, use a 1/2-in. socket wrench and a number 2 Phillips screwdriver to remove the bolts and screws from the brackets.
11.
Store the brackets and bolts inside the accessory box.
178 Copyright © 2019, Juniper Networks, Inc.
Chapter 15: Unpacking the T1600 Router
12.
Save the shipping crate cover, pallet, and packing materials in case you need to move or ship the router at a later time.
13.
Proceed with the installation.
Figure 63: Contents of the Shipping Crate
Related
Documentation
•
Verifying the T1600 Router Parts Received on page 179
•
Mounting the T1600 Chassis Using a Mechanical Lift on page 198
•
Installing the T1600 Chassis in the Rack Manually on page 217
•
T1600 Router Description on page 3
Verifying the T1600 Router Parts Received
A packing list is included in each shipment. Check the parts in the shipment against the items on the packing list. The packing list specifies the part numbers and descriptions of each part in your order.
If any part is missing, contact a customer service representative.
The main shipment contains the router chassis with installed components, listed in
, and an accessory box, which contains the parts listed in
.
Table 102: Router Parts List
Component Quantity
Chassis, including midplane, craft interface
FPCs
1
Up to 8
Copyright © 2019, Juniper Networks, Inc.
179
T1600 Core Router Hardware Guide
Table 102: Router Parts List (continued)
Component
PICs
SIBs
Routing Engines
Control boards
SCGs
Power supplies
CIP
Front fan trays
Rear fan tray
Quick Start installation
Large mounting shelf—Required for all mounting options.
Small mounting shelf—Required only for four-post rack or cabinet
Spacer bars (attached to the back of the front-mounting flanges on the chassis—Required only for four-post rack or cabinet
Blank panels for slots without components installed
1
1
1
1
2
1 or 2
2
1
Quantity
Up to 4 per FPC
5
1 or 2
1 or 2 (one for each Routing Engine)
2
One blank panel for each slot not occupied by a component
180 Copyright © 2019, Juniper Networks, Inc.
Chapter 15: Unpacking the T1600 Router
Table 103: Accessory Box Parts List
Part Quantity
Affidavit for T1 connection
Connectors for alarm relay cables
DB-9 (male) to DB-25
(female) adapter
ESD wrist strap with cable
1
2
1
1
Ethernet cable, 15-ft length, to connect Routing Engine to management device
1
PCMCIA Card holder and hook-and-loop fasteners
(male and female)
1 of each
DC power and grounding cable lugs
36 lugs are included.
One lug is for the grounding cable. The remaining cable lugs are for the DC power cables. The number of cable lugs varies depending on the power supply and how many cables are being connected.
Screws to fasten grounding cable to chassis
2
Washers for grounding cable lug
2
Optional cable management restraints
2
Product warranty
Read me first document
1
1
Screws to mount chassis
Serial cable, 6-ft length, to connect Routing Engine to management console
End User License Agreement 1
Bag of 14
1
Related
Documentation
•
T1600 Router Description on page 3
•
Overview of Unpacking the T1600 Router on page 177
Copyright © 2019, Juniper Networks, Inc.
181
T1600 Core Router Hardware Guide
•
Unpacking the T1600 Router on page 178
182 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 16
Installing the T1600 Mounting Hardware
•
Installing the T1600 Mounting Hardware for a Four-Post Rack or Cabinet on page 183
•
Installing the T1600 Mounting Hardware for an Open-Frame Rack on page 188
Installing the T1600 Mounting Hardware for a Four-Post Rack or Cabinet
1.
Installing Cage Nuts, If Needed on page 183
2.
Installing the Large Mounting Shelf on page 184
3.
Installing the Small Shelf on page 185
4.
Installing the Spacer Bars on page 186
5.
Removing the Center-Mounting Brackets from the Chassis on page 187
Installing Cage Nuts, If Needed
To install the cage nuts, if needed, in the mounting holes specified in
1.
On the front rack rails, install cage nuts in the holes specified for the large shelf and the spacer bars.
2.
On the rear rack rails, install cage nuts in the holes specified for the small shelf.
The front-mounting flanges have holes for rack-mounting screws, spaced at 5.25 in.
(13.34 cm).
specifies the holes in which you insert mounting screws
(an X indicates a mounting hole location), and cage nuts if needed. The hole distances are relative to one of the standard “U” divisions on the rack. The bottom of all mounting shelves is at 0.04 in. (0.02 U) above a “U” division.
Table 104: Four-Post or Cabinet Rack Mounting Hole Locations
Hole Distance Above “U” Division
Large
Shelf
Spacer
Bars
Small
Shelf
60
51
42
34.75 in. (88.3 cm)
29.51 in. (74.9 cm)
24.26 in. (61.6 cm)
19.86 U
16.86 U
13.86 U
X
X
X
Copyright © 2019, Juniper Networks, Inc.
183
T1600 Core Router Hardware Guide
6
3
2
15
12
33
24
9
Table 104: Four-Post or Cabinet Rack Mounting Hole Locations (continued)
Hole Distance Above “U” Division
Large
Shelf
Spacer
Bars
Small
Shelf
19.01 in. (48.3 cm)
13.76 in. (34.9 cm)
8.51 in. (21.6 cm)
6.76 in. (17.1 cm)
5.01 in. (12.7 cm)
10.86 U
7.86 U
4.86 U
3.86 U
2.86 U
X
X
X X
X
X
3.26 in. (8.3 cm)
1.51 in. (3.8 cm)
0.88 in. (2.2 cm)
1.86 U
0.86 U
0.50 U X
X X
X
Installing the Large Mounting Shelf
To install the large mounting shelf:
1.
On the front of each front rack rail, partially insert a mounting screw into the lowest hole specified in
for the large shelf and the spacer bars.
2.
Install the large shelf on the front rack rails. Rest the bottom slot of each flange on a mounting screw.
3.
Partially insert a mounting screw into the top hole in each flange of the large shelf.
4.
Tighten all the screws completely.
184 Copyright © 2019, Juniper Networks, Inc.
Chapter 16: Installing the T1600 Mounting Hardware
Figure 64: Installing the Mounting Hardware for a Four-Post Rack or Cabinet
Installing the Small Shelf
To install the small shelf:
1.
On the back of each rear rack rail, partially insert a mounting screw into the lowest hole specified in
for the small shelf.
2.
Install the small shelf on the back rack rails. Rest the bottom slot of each flange on a mounting screw. The small shelf installs on the back of the rear rails, extending toward the center of the rack. The bottom of the small shelf on the rear rack rails must align with the bottom of the large shelf on the front rack rails.
3.
Partially insert screws into the open holes in the flanges of the small shelf.
4.
Tighten all the screws completely.
Copyright © 2019, Juniper Networks, Inc.
185
T1600 Core Router Hardware Guide
Installing the Spacer Bars
The router is shipped with each spacer bar attached to the rear of each front-mounting flange.
To install the spacer bars:
1.
Remove each spacer bar by removing the screws that fasten the spacer bar to the front-mounting flange.
2.
Place one of the spacer bars over a flange of the large shelf. Position the notch in the rear of the spacer bar so the upper part of the bar is flush with the rack rail and the lower part is flush with the flange of the shelf (see
).
3.
Insert a mounting screw into each of the nonthreaded holes in the recesses of the spacer bar to secure the spacer bar. Each hole should have a cage nut behind it.
4.
Repeat Steps
and
for the other spacer bar.
5.
Tighten all the screws completely.
Figure 65: Positioning the Spacer Bar on the Rack
186 Copyright © 2019, Juniper Networks, Inc.
Chapter 16: Installing the T1600 Mounting Hardware
Removing the Center-Mounting Brackets from the Chassis
You must remove the center-mounting brackets before installing the chassis in a four-post rack or cabinet.
To remove the center-mounting brackets (see
1.
Loosen the screws at the top and bottom of each bracket.
2.
Remove each bracket.
Figure 66: Removing the Center-Mounting Bracket
Front-mounting flange
Center-mounting bracket
Craft interface
Fan tray
FPCs
CIP
ESD point
Air filter
Fan tray
Air intake
Related
Documentation
•
T1600 Router Description on page 3
•
Overview of Installing the T1600 Router on page 175
Copyright © 2019, Juniper Networks, Inc.
187
T1600 Core Router Hardware Guide
•
T1600 Site Preparation Requirements Checklist on page 137
Installing the T1600 Mounting Hardware for an Open-Frame Rack
In an open-frame rack, center-mounting is generally preferable to front-mounting because the more even distribution of weight provides greater stability. If you center-mount the chassis, you use the center-mounting brackets attached to the chassis. If you front-mount the chassis, you use the front-mounting flanges, and must remove the center-mounting brackets.
1.
Installing the Cage Nuts, If Needed on page 188
2.
Installing the Large Mounting Shelf on page 188
3.
Removing the Center-Mounting Brackets from the Chassis on page 189
4.
Removing the Spacer Bars on page 190
Installing the Cage Nuts, If Needed
Install cage nuts, if needed, in the mounting holes specified in
.
specifies the mounting holes in which you insert the mounting screws (an X indicates a mounting hole location), and cage nuts if needed. The hole distances are relative to one of the standard “U” divisions on the rack. For reference, the bottom of all mounting shelves is at 0.04 in. (0.02 U) above a “U” division.
Table 105: Open-Frame Rack Mounting Hole Locations
Hole Distance Above “U” Division Large Shelf
59
53
50
44
34.13 in. (86.7 cm)
30.63 in. (77.8 cm)
28.88 in. (73.3 cm)
25.38 in. (64.5 cm)
19.50 U
17.50 U
16.50 U
14.50 U
X
X
X
X
32
31
41
35
23.63 in. (60.0 cm)
20.13 in. (51.1 cm)
18.38 in. (46.7 cm)
17.75 in. (45.1 cm)
13.50 U
11.50 U
10.50 U
10.14 U
X
X
X
X
Installing the Large Mounting Shelf
To install the large mounting shelf (see
) in an open-frame rack:
188 Copyright © 2019, Juniper Networks, Inc.
Chapter 16: Installing the T1600 Mounting Hardware
1.
On the rear of each rack rail, partially insert a mounting screw into the lowest hole specified in
for the large shelf.
2.
Install the large shelf on the rack. Rest the bottom slot of each flange on a mounting screw.
3.
Partially insert screws into the open holes in the flanges of the large shelf.
4.
Tighten all the screws completely.
Figure 67: Installing the Mounting Hardware for an Open-Frame Rack
Removing the Center-Mounting Brackets from the Chassis
Before front-mounting the router in an open-frame rack, you must remove the center-mounting brackets from the chassis.
To remove the center-mounting brackets (see
1.
Loosen the screws at the top and bottom of each bracket.
Copyright © 2019, Juniper Networks, Inc.
189
T1600 Core Router Hardware Guide
2.
Remove each bracket.
Figure 68: Removing the Center-Mounting Bracket
Front-mounting flange
Center-mounting bracket
Craft interface
Fan tray
FPCs
CIP
ESD point
Air filter
Fan tray
Air intake
Removing the Spacer Bars
The router is shipped with each spacer bar attached to the rear of each front-mounting flange. If you are installing the chassis in an open-frame rack, removing the spacer bars is optional.
To remove the spacer bars:
1.
Remove the screws that fasten the spacer bar to the front-mounting flange.
2.
Remove the spacer bars.
190 Copyright © 2019, Juniper Networks, Inc.
Chapter 16: Installing the T1600 Mounting Hardware
Related
Documentation
•
T1600 Router Description on page 3
•
Overview of Installing the T1600 Router on page 175
•
T1600 Site Preparation Requirements Checklist on page 137
Copyright © 2019, Juniper Networks, Inc.
191
T1600 Core Router Hardware Guide
192 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 17
Installing the T1600 Router into a Rack
•
Overview of Installing the T1600 Router into the Rack on page 193
Overview of Installing the T1600 Router into the Rack
1.
Read the safety information. To avoid harm to yourself or the router as you lift it into the rack, follow the guidelines and safety procedures for working with routers.
See
“T1600 Chassis Lifting Guidelines” on page 595
, and
“General Safety Guidelines for Juniper Networks Devices” on page 585 .
2.
Verify that the site has been prepared for the router installation.
See
“T1600 Site Preparation Requirements Checklist” on page 137 .
3.
Because of the T1600 router's size and weight—up to 606 lb (275 kg) fully configured—we strongly recommend that you lift the router into the rack using a mechanical lift. However, if a mechanical lift is not available, you can remove components from the chassis to make it easier to install into the rack. With components removed, the chassis weighs approximately 225 lb (102 kg), and four people can lift the chassis into the rack manually.
Related
Documentation
•
Overview of Installing a T1600 Router Using a Mechanical Lift on page 195
•
Overview of Installing a T1600 Router Without a Mechanical Lift on page 203
Copyright © 2019, Juniper Networks, Inc.
193
T1600 Core Router Hardware Guide
194 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 18
Installing the T1600 Router into a Rack
Using a Mechanical Lift
•
Overview of Installing a T1600 Router Using a Mechanical Lift on page 195
•
Tools Required to Install the T1600 Router Using a Mechanical Lift on page 196
•
Removing the T1600 Power Supplies on page 196
•
Attaching the T1600 Installation Handle on page 197
•
Mounting the T1600 Chassis Using a Mechanical Lift on page 198
•
Removing the T1600 Installation Handle and Reinstalling the Power Supplies on page 201
Overview of Installing a T1600 Router Using a Mechanical Lift
Because of the T1600 router's size and weight—up to 606 lb (275 kg) depending on the configuration—we strongly recommend that you install the router using a mechanical lift.
1.
Verify that the mounting hardware has been installed as described in
T1600 Mounting Hardware for an Open-Frame Rack” on page 188
or
T1600 Mounting Hardware for a Four-Post Rack or Cabinet” on page 183
.
2.
Remove the router from the shipping crate as described in
.
3.
Gather the tools required to install the router.
See
“Tools Required to Install the T1600 Router Using a Mechanical Lift” on page 196
4.
Remove the power supplies.
See
“Removing the T1600 Power Supplies” on page 196 .
5.
Attach the T1600 installation handle.
See
“Attaching the T1600 Installation Handle” on page 197
.
6.
Mount the T1600 chassis in the rack or cabinet.
Copyright © 2019, Juniper Networks, Inc.
195
T1600 Core Router Hardware Guide
See
“Mounting the T1600 Chassis Using a Mechanical Lift” on page 198
.
7.
Remove the T1600 installation handle, and reinstall the power supplies.
See
“Removing the T1600 Installation Handle and Reinstalling the Power Supplies” on page 201
.
Tools Required to Install the T1600 Router Using a Mechanical Lift
To install the T320 chassis using a mechanical lift, you need the following tools:
• Mechanical lift
• Phillips (+) screwdrivers, number 2
Related
Documentation
•
T1600 Router Description on page 3
•
General Safety Guidelines for Juniper Networks Devices on page 585
•
T1600 General Electrical Safety Guidelines on page 613
Removing the T1600 Power Supplies
This procedure can be used for the three-input 240-A DC power supplies, four-input
240-A DC power supplies, three-phase delta AC power supplies, or three-phase wye power supplies. To remove the power supplies, start with the upper power supply:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
For three-input 240-A DC power supplies or four-input 240-A DC power supplies, switch the circuit breakers on the power supply faceplate to the off position ( O ). For
AC power supplies or six-input DC power supplies, switch the power switch to the standby position. We recommend this even though the power supplies are not connected to power sources.
3.
Loosen the captive screws on the lower corners of the power supply faceplate completely.
4.
Twist the ejector handles on the upper corners of the faceplate counterclockwise to unseat the power supply.
5.
Grasp the handle on the power supply faceplate and pull firmly to start removing the power supply. Slide it halfway out of the chassis (see
.
CAUTION: Be prepared to support the full weight of the power supply as you remove it from the router. Each three-input 240-A DC power supply
196 Copyright © 2019, Juniper Networks, Inc.
Chapter 18: Installing the T1600 Router into a Rack Using a Mechanical Lift weighs approximately 25 lb (11.3 kg). Each four-input 240-A DC power supply weighs approximately 26.6 lb (12.0 kg). Each six-input DC power supplies weighs 39.7 lb (18.0 kg). Each three-phase delta and wye power supply weighs approximately 31.0 lb (14.06 kg).
6.
Place one hand underneath the power supply to support it and slide it completely out of the chassis.
7.
Repeat the procedure for the other power supply.
Figure 69: Removing a Three-Input 240-A DC Power Supply
Related
Documentation
•
Overview of Installing a T1600 Router Using a Mechanical Lift on page 195
•
Attaching the T1600 Installation Handle on page 197
•
Mounting the T1600 Chassis Using a Mechanical Lift on page 198
•
Removing the T1600 Installation Handle and Reinstalling the Power Supplies on page 201
Attaching the T1600 Installation Handle
To assist you with the installation of the router, attach the installation handle over the power supply slots of the chassis. To attach the installation handle:
1.
Place the installation handle over the location of the lower power supply.
2.
Tighten the captive screws of the handle into the holes previously occupied by the captive screws of the power supply (see
).
Copyright © 2019, Juniper Networks, Inc.
197
T1600 Core Router Hardware Guide
Figure 70: Attaching the Installation Handle
Related
Documentation
•
Overview of Installing a T1600 Router Using a Mechanical Lift on page 195
•
Removing the T1600 Power Supplies on page 196
•
Mounting the T1600 Chassis Using a Mechanical Lift on page 198
•
Removing the T1600 Installation Handle and Reinstalling the Power Supplies on page 201
Mounting the T1600 Chassis Using a Mechanical Lift
Because of the router's size and weight—up to 606 lb (275 kg) depending on configuration—we strongly recommend that you install the router using a lift.
To mount the chassis in the rack or cabinet using a lift (see
):
1.
If you are installing the router in an open-frame rack, ensure that the rack is in its permanent location and is secured to the building. Ensure that the installation site allows adequate clearance for both airflow and maintenance. For details, see
“Clearance Requirements for Airflow and T1600 Hardware Maintenance” on page 143 .
2.
Load the router onto the lift, making sure it rests securely on the lift platform.
CAUTION: Do not lift the router using the installation handle or the handles on the sides of the chassis. Use these handles only to help position the router.
3.
Using the lift, position the chassis in front of the rack or cabinet, centering it in front of the mounting shelves.
198 Copyright © 2019, Juniper Networks, Inc.
Chapter 18: Installing the T1600 Router into a Rack Using a Mechanical Lift
4.
Lift the chassis approximately 0.75 in. above the surface of the mounting shelves and position it as close as possible to the shelves.
5.
Carefully slide the chassis onto the mounting shelves so that the bottom of the chassis and the mounting shelves overlap by approximately 2 inches.
6.
With one person pulling on the installation handle from the rear of the rack or cabinet while two people push on the front-mounting flanges, slide the chassis onto the mounting shelves until the mounting brackets or front-mounting flanges contact the rack rails or spacer bars (depending on your type of installation). The shelves ensure that the holes in the mounting brackets and the front-mounting flanges of the chassis align with the holes in the rack rails.
7.
Move the lift away from the rack.
8.
If you are installing the router in a four-post rack or cabinet, install a mounting screw and a cage nut into each of the holes aligned with the threaded holes in the spacer bars. If you are installing the router in an open-frame rack, install a mounting screw into each of the open mounting holes aligned with the rack, starting from the bottom.
9.
Visually inspect the alignment of the router. If the router is installed properly in the rack, all the mounting screws on one side of the rack should be aligned with the mounting screws on the opposite side and the router should be level.
Copyright © 2019, Juniper Networks, Inc.
199
T1600 Core Router Hardware Guide
Figure 71: Installing the Router in a Four-Post Rack
200
NOTE: This illustration depicts the router being installed in a four-post rack.
Related
Documentation
•
Overview of Installing a T1600 Router Using a Mechanical Lift on page 195
•
Removing the T1600 Power Supplies on page 196
•
Attaching the T1600 Installation Handle on page 197
•
T1600 Chassis Lifting Guidelines on page 595
•
Removing the T1600 Installation Handle and Reinstalling the Power Supplies on page 201
Copyright © 2019, Juniper Networks, Inc.
Chapter 18: Installing the T1600 Router into a Rack Using a Mechanical Lift
Removing the T1600 Installation Handle and Reinstalling the Power Supplies
After you have installed the router, remove the installation handle and reinstall the two power supplies in the chassis by following this procedure, starting with the lower power supply (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Loosen the captive screws on the installation handle completely, and remove the handle from the chassis.
3.
For three-input 240-A DC power supplies or four-input 240-A DC power supplies, switch the circuit breakers on the power supply faceplate to the off position ( O ). For the AC power supplies or six-input DC power supplies, switch the power switch on the power supply to the standby position.
4.
Using both hands, slide the power supply into the chassis until you feel resistance.
5.
Twist the ejector handles at the upper corners of the power supply faceplate clockwise until they stop.
6.
Tighten the captive screws at the lower corners of the power supply faceplate to secure the power supply in the chassis.
7.
Repeat the procedure for the upper power supply.
Figure 72: Reinstalling a Three-Input 240-A DC Power Supply
Copyright © 2019, Juniper Networks, Inc.
201
T1600 Core Router Hardware Guide
Figure 73: Reinstalling a Four-Input 240-A DC Power Supply
Related
Documentation
•
Overview of Installing a T1600 Router Using a Mechanical Lift on page 195
•
Removing the T1600 Power Supplies on page 196
•
Attaching the T1600 Installation Handle on page 197
•
Mounting the T1600 Chassis Using a Mechanical Lift on page 198
202 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 19
Installing the T1600 Router into a Rack
Without a Mechanical Lift
•
Overview of Installing a T1600 Router Without a Mechanical Lift on page 203
•
Tools and Parts Required to Install the T1600 Router Without a Mechanical
•
Removing Components from the T1600 Chassis on page 204
•
Installing the T1600 Chassis in the Rack Manually on page 217
•
Reinstalling the T1600 Components in the Chassis on page 220
Overview of Installing a T1600 Router Without a Mechanical Lift
If you cannot use a mechanical lift to install the T1600 router (the preferred method), you can install it manually.
To install the T1600 router without a mechanical lift:
1.
Read the safety information. To avoid harm to yourself or the router as you install and maintain it, follow the guidelines for working with and near electrical equipment, as well as the safety procedures for working with routers. However, providing an exhaustive set of guidelines for working with electrical equipment is beyond the scope of this documentation.
See
“General Safety Guidelines for Juniper Networks Devices” on page 585
,
General Electrical Safety Guidelines” on page 613 , and
“T1600 Chassis Lifting Guidelines” on page 595
2.
Verify that the site has been prepared for the router installation.
See
“T1600 Site Preparation Requirements Checklist” on page 137 .
3.
Verify that the mounting hardware has been installed as described in
T1600 Mounting Hardware for an Open-Frame Rack” on page 188
or
T1600 Mounting Hardware for a Four-Post Rack or Cabinet” on page 183
.
4.
Remove the router from the shipping crate as described in
.
Copyright © 2019, Juniper Networks, Inc.
203
T1600 Core Router Hardware Guide
5.
Gather the tools required to install the router.
See
“Tools and Parts Required to Install the T1600 Router Without a Mechanical Lift” on page 204
.
6.
Remove components from the chassis to make it easier to install into the rack or chassis.
See
“Removing Components from the T1600 Chassis” on page 204 .
7.
Install the T1600 Chassis in the rack manually. At least four people are needed to safely lift the chassis into the rack or cabinet. With components removed, the chassis weighs approximately 225 lb (102 kg).
See
“Installing the T1600 Chassis in the Rack Manually” on page 217 .
8.
Reinstall the components removed from the chassis.
See
“Reinstalling the T1600 Components in the Chassis” on page 220
.
Tools and Parts Required to Install the T1600 Router Without a Mechanical Lift
To install the router, you need the following tools and parts:
• Phillips (+) screwdrivers, numbers 1 and 2
• Flat-blade (–) screwdriver, number 1
• 7/16-in. (11 mm) socket wrench
• 3/8-in. nut driver
• ESD grounding wrist strap
Related
Documentation
•
T1600 Site Preparation Requirements Checklist on page 137
•
General Safety Guidelines for Juniper Networks Devices on page 585
•
T1600 General Electrical Safety Guidelines on page 613
Removing Components from the T1600 Chassis
To make the router light enough to install manually, you first remove most components from the chassis. These procedures for removing components from the chassis are for initial installation only, and assume that you have not connected power cables to the router. The following procedures describe how to remove components from the chassis, first from the rear and then from the front:
1.
Removing the T1600 DC Power Supplies on page 205
2.
Removing the T1600 AC Power Supplies on page 206
3.
Removing the T1600 SIBs on page 208
204 Copyright © 2019, Juniper Networks, Inc.
Chapter 19: Installing the T1600 Router into a Rack Without a Mechanical Lift
4.
Removing the T1600 Control Boards on page 209
5.
Removing the T1600 SCGs on page 210
6.
Removing the T1600 Standard or Quiet Rear Fan Tray on page 211
7.
Removing the T1600 Front Cable Management System on page 212
8.
Removing the T1600 Standard or Quiet Front Fan Trays on page 213
9.
Removing the T1600 FPCs on page 215
Removing the T1600 DC Power Supplies
The power supplies are located at the rear of the chassis below the SIBs. Each three-input
240-A DC power supply weighs approximately 25 lb (11.3 kg). Each four-input 240-A DC power supply weighs approximately 26.6 lb (12.0 kg). Each six-input DC power supply weights approximately 39.7 lb (18.0 kg).
To remove the power supplies, starting with the upper power supply:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
For three-input 240-A DC power supplies or four-input 240-A DC power supplies, switch the circuit breakers on the power supply faceplate to the off position ( O ). For six-input DC power supplies, switch the power switch on the power supply to the standby position. We recommend this even though the power supplies are not connected to power sources.
3.
Loosen the captive screws on the lower corners of the power supply faceplate completely.
4.
Twist the ejector handles on the upper corners of the faceplate counterclockwise to unseat the power supply.
5.
Grasp the handle on the power supply faceplate and pull firmly to start removing the power supply. Slide it halfway out of the chassis (see
6.
Place one hand underneath the power supply to support it and slide it completely out of the chassis.
CAUTION: Be prepared to support the full weight of the power supply as you remove it from the router.
7.
Repeat the procedure for the other power supply.
Copyright © 2019, Juniper Networks, Inc.
205
T1600 Core Router Hardware Guide
Figure 74: Removing a Three-Input 240-A DC Power Supply Before Installing the Router
Figure 75: Removing a Four-Input 240-A Power Supply Before Installing the Router
See Also •
Maintaining the T1600 Power Supplies on page 525
• Reinstalling the T1600 DC Power Supplies
Removing the T1600 AC Power Supplies
The power supplies are located at the rear of the chassis below the SIBs. Each three-phase delta AC power supply weighs approximately 25 lb (11.3 kg). Each three-phase wye AC power supply weighs approximately 26.6 lb (12.0 kg).
To remove the AC power supplies, starting with the upper power supply:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Switch the power switch on the power supply faceplate to the standby position. We recommend this even though the power supplies are not connected to power sources.
206 Copyright © 2019, Juniper Networks, Inc.
Chapter 19: Installing the T1600 Router into a Rack Without a Mechanical Lift
3.
Loosen the captive screws on the lower corners of the power supply faceplate completely.
4.
Twist the ejector handles on the upper corners of the faceplate counterclockwise to unseat the power supply.
5.
Grasp the handle on the power supply faceplate and pull firmly to start removing the power supply. Slide it halfway out of the chassis (see
6.
Place one hand underneath the power supply to support it and slide it completely out of the chassis.
CAUTION: Be prepared to support the full weight of the power supply as you remove it from the router.
7.
Repeat the procedure for the other power supply.
Figure 76: Removing a Three-Phase Delta AC Power Supply Before Installing the Router
Copyright © 2019, Juniper Networks, Inc.
207
T1600 Core Router Hardware Guide
Figure 77: Removing a Three-Phase Wye AC Power Supply Before Installing the Router
See Also •
Maintaining the T1600 Power Supplies on page 525
• Reinstalling the T1600 DC Power Supplies
Removing the T1600 SIBs
Five SIBs are installed in the router. The SIBs are located in the rear of the chassis in the slots marked SIB0 through SIB4 . Each T1600-SIB weighs approximately 6.5 lb (3 kg).
Each TXP-T1600 SIB weighs approximately 10.2 lb (4.6 kg).
To remove the SIBs (see
):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
3.
Loosen the captive screws (using a Phillips (+) screwdriver, number 2) on the ejector handles on each side of the SIB faceplate.
4.
Flip the ejector handles outward to unseat the SIB.
5.
Grasp both ejector handles, pull firmly, and slide the SIB about three-quarters of the way out of the chassis.
6.
Place one hand underneath the SIB to support it and slide it completely out of the chassis. Place it on the antistatic mat.
208 Copyright © 2019, Juniper Networks, Inc.
Chapter 19: Installing the T1600 Router into a Rack Without a Mechanical Lift
CAUTION: Do not stack hardware components on one another after you remove them. Place each component on an antistatic mat resting on a stable, flat surface.
7.
Repeat the procedure for each of the remaining SIBs.
Figure 78: Removing a SIB
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
• Reinstalling the T1600 SIBs
•
Maintaining the T1600 SIBs on page 531
•
T1600 Switch Interface Board (SIB) Description on page 127
Removing the T1600 Control Boards
The router can have one or two control boards. They are located in the upper rear of the chassis in the slots marked CB0 and CB1 . Each T-CB and LCC-CB weighs approximately
5 lb (2.3 kg).
To remove the control boards (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
Copyright © 2019, Juniper Networks, Inc.
209
T1600 Core Router Hardware Guide
3.
Loosen the captive screws on the ejector handles on both sides of the control board faceplate.
4.
Flip the ejector handles outward to unseat the control board.
5.
Grasp the ejector handles and slide the control board about halfway out of the chassis.
6.
Place one hand underneath the control board to support it and slide it completely out of the chassis. Place it on the antistatic mat.
CAUTION: Do not stack hardware components on one another after you remove them. Place each component on an antistatic mat resting on a stable, flat surface.
7.
Repeat the procedure for the second control board.
Figure 79: Removing a Control Board
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Installing a T1600 T-CB on page 369
Removing the T1600 SCGs
The router can have one or two SCGs installed. The SCGs are located in the upper rear of the chassis, above the control boards and Routing Engines. Each SCG weighs approximately 1.9 lb (0.9 kg).
To remove the SCGs (see
):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site..
210 Copyright © 2019, Juniper Networks, Inc.
Chapter 19: Installing the T1600 Router into a Rack Without a Mechanical Lift
3.
Loosen the captive screws on the edges of the SCG faceplate.
4.
Grasp the SCG by the handle on the faceplate and slide it out of the chassis.
5.
Place the SCG on the antistatic mat.
6.
Repeat the procedure for the second SCG.
Figure 80: Removing an SCG
See Also •
T1600 SONET Clock Generators Description on page 30
•
Installing the T1600 SCG on page 334
•
Maintaining the T1600 SCGs on page 530
•
Replacing a T1600 SCG on page 333
Removing the T1600 Standard or Quiet Rear Fan Tray
The rear fan tray is mounted vertically on the right side of the rear of the chassis. The standard or quiet rear fan tray weighs about 10 lb (4.5 kg).
To remove the standard rear fan tray (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Loosen the captive screws on the top and bottom of the fan tray faceplate.
3.
Grasp the handles and pull the fan tray halfway out of the chassis.
4.
Place one hand under the fan tray to support it and pull the fan tray completely out of the chassis.
Copyright © 2019, Juniper Networks, Inc.
211
T1600 Core Router Hardware Guide
Figure 81: Removing the T1600 Rear Fan Tray
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 Cooling System Description on page 39
Removing the T1600 Front Cable Management System
The front cable management system is located below the FPC card cage. The cable management system weighs approximately 5 lb (2.3 kg).
To remove the front cable management system:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Using a 3/8-in. nut driver, unscrew the nuts on the corners of the cable management system.
212 Copyright © 2019, Juniper Networks, Inc.
Chapter 19: Installing the T1600 Router into a Rack Without a Mechanical Lift
3.
Grasp the bottom of the cable management system and pull it straight out from the studs on the front of the chassis.
See Also •
T1600 Front Cable Management System Description on page 25
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Removing the T1600 Standard or Quiet Front Fan Trays
The upper front fan tray is located above the FPC card cage, and the lower front fan tray is located below the air filter. Each standard front fan tray weighs about 18.6 lb (8.4 kg).
Each quiet front fan tray weighs about 17.8 lb (8.1 kg).
To remove the standard front fan trays (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Loosen the captive screws on the corners of the faceplate of one of the fan trays.
3.
Grasp the handles and pull the fan tray halfway out of the chassis.
4.
Place one hand under the fan tray to support it and pull the fan tray completely out of the chassis.
5.
Repeat the procedure to remove the remaining front fan tray.
To remove a quiet upper front fan tray (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Loosen the captive screws on the corners of the fan tray faceplate.
3.
Grasp the handles on the faceplate, and pull the fan tray out of the chassis approximately 1 to 3 inches.
4.
Press the two latches located on each side of the fan tray up to release the fan tray from the chassis.
5.
Place one hand under the fan tray to support it and pull the fan tray completely out of the chassis.
Copyright © 2019, Juniper Networks, Inc.
213
T1600 Core Router Hardware Guide
To remove the quiet lower front fan tray (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Loosen the captive screws on the corners of the fan tray faceplate.
3.
Grasp the handles, and pull the fan tray out of the chassis approximately 1 to 3 inches.
4.
Press the two latches located on each side of the fan tray up to release the fan tray from the chassis.
5.
Place one hand under the fan tray to support it and pull the fan tray completely out of the chassis.
Figure 82: Removing a Standard Front Fan Tray
Figure 83: Removing the Quiet Upper Front Fan Tray
214 Copyright © 2019, Juniper Networks, Inc.
Chapter 19: Installing the T1600 Router into a Rack Without a Mechanical Lift
Figure 84: Removing the Quiet Lower Front Fan Tray
See Also •
Overview of Installing a T1600 Router Without a Mechanical Lift on page 203
Removing the T1600 FPCs
The router holds up to eight FPCs, which are installed vertically in the front of the router.
An empty FPC weighs approximately 25 lb (11.3 kg) and an FPC with PICs installed can weigh up to 37 lb (14.5 kg).
Each FPC slot not occupied by an FPC must be covered by an FPC blank panel. An FPC blank panel weighs 7 lb (3 kg).
To remove an FPC (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
3.
Before removing the FPCs, record their location in the chassis so that you can reinstall each FPC in the correct slot.
4.
If you are removing a Type 2 FPC or Type 3 FPC, loosen the screws inside the ejector handles at the top and bottom of the FPC faceplate.
5.
Simultaneously turn both the ejector handles counterclockwise to unseat the FPC.
6.
Grasp the handles and slide the FPC straight out of the card cage halfway.
7.
Place one hand around the front of the FPC (the PIC housing) and the other hand under it to support it. Slide the FPC completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.
Copyright © 2019, Juniper Networks, Inc.
215
T1600 Core Router Hardware Guide
CAUTION: The weight of the FPC is concentrated in the back end. Be prepared to accept the full weight—up to 37 lb (14.5 kg)—as you slide the
FPC out of the chassis.
When the FPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
Do not stack FPCs on top of one another after removal. Place each one individually in an electrostatic bag or on its own antistatic mat on a flat, stable surface.
8.
Repeat the procedure for each remaining FPC.
Figure 85: Removing an FPC
216
See Also
T-1600 FPC4
Copyright © 2019, Juniper Networks, Inc.
Chapter 19: Installing the T1600 Router into a Rack Without a Mechanical Lift
Related
Documentation
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 Front Cable Management System Description on page 25
•
Holding T1600 FPCs on page 515
•
Storing T1600 FPCs on page 520
•
Maintaining the T1600 Fan Trays on page 512
Installing the T1600 Chassis in the Rack Manually
To install the router in the rack (see
CAUTION: If you are installing two routers in one rack, install the lower one first. Installing a router in the upper position in a rack or cabinet requires a lift.
CAUTION: Before front-mounting the router in a rack, have a qualified technician verify that the rack is strong enough to support the router's weight and is adequately supported at the installation site.
CAUTION: Lifting the chassis and mounting it in a rack requires four people.
The empty chassis weighs approximately 225 lb (102 kg).
1.
If you are installing the router in an open-frame rack, ensure that the rack is in its permanent location and is secured to the building.
2.
Ensure that the installation site allows adequate clearance for both airflow and maintenance. For details, see
“Clearance Requirements for Airflow and T1600
Hardware Maintenance” on page 143
.
3.
Attach the installation handle by tightening the captive screws of the handle into the holes previously occupied by the captive screws of the power supplies (see
). Tighten the screws, using a Phillips (+) screwdriver, number 2.
Copyright © 2019, Juniper Networks, Inc.
217
T1600 Core Router Hardware Guide
Figure 86: Attaching the Installation Handle
218
4.
Position the router in front of the rack or cabinet, centering it in front of the mounting shelves. Use a pallet jack if one is available.
CAUTION: Do not lift the router using the installation handle or the handles on the sides of the chassis. Use these handles only to help position the router.
5.
With two people in the front and two people in the back, hold onto the bottom of the chassis and carefully lift it onto the mounting shelves.
WARNING: To prevent injury, keep your back straight and lift with your legs, not your back. Avoid twisting your body as you lift. Balance the load evenly and be sure that your footing is solid.
6.
With one person pulling on the installation handle from the rear of the rack or cabinet while two people push on the front-mounting flanges, slide the router onto the mounting shelves until the mounting brackets or front-mounting flanges contact the rack rails or spacer bars (depending on your type of installation). The shelves ensure that the holes in the mounting brackets and the front-mounting flanges of the chassis align with the holes in the rack rails.
7.
If you are installing the router in a four-post rack or cabinet, install a mounting screw and a cage nut into each of the holes aligned with the threaded holes in the spacer bars. If you are installing the router in an open-frame rack, install a mounting screw into each of the open mounting holes aligned with the rack, starting from the bottom.
Copyright © 2019, Juniper Networks, Inc.
Chapter 19: Installing the T1600 Router into a Rack Without a Mechanical Lift
8.
Loosen the captive screws on the installation handle completely, and remove the handle from the chassis.
9.
Visually inspect the alignment of the router. If the router is installed properly in the rack, all the mounting screws on one side of the rack should be aligned with the mounting screws on the opposite side and the router should be level.
Figure 87: Installing the Router in the Rack
NOTE: This illustration depicts the router being installed in a four-post rack.
For an illustration of an open-frame rack, see
“Installing the T1600 Mounting
Hardware for an Open-Frame Rack” on page 188
.
Related
Documentation
•
Overview of Installing the T1600 Router on page 175
•
Overview of Installing a T1600 Router Without a Mechanical Lift on page 203
•
T1600 Chassis Lifting Guidelines on page 595
•
Reinstalling the T1600 Components in the Chassis on page 220
Copyright © 2019, Juniper Networks, Inc.
219
T1600 Core Router Hardware Guide
Reinstalling the T1600 Components in the Chassis
1.
Reinstalling the T1600 Standard or Quiet Rear Fan Tray on page 220
2.
Reinstalling the T1600 SCGs on page 221
3.
Reinstalling the T1600 Control Boards on page 222
4.
Reinstalling the T1600 SIBs on page 223
5.
Reinstalling the T1600 Power Supplies on page 224
6.
Reinstalling the T1600 FPCs on page 226
7.
Reinstalling T1600 Standard Front Fan Trays on page 227
8.
Reinstalling T1600 Quiet Fan Trays on page 228
9.
Reinstalling the T1600 Front Cable Management System on page 229
Reinstalling the T1600 Standard or Quiet Rear Fan Tray
To reinstall the standard or quiet rear fan tray (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Grasp the fan tray by its handles and insert it straight into the chassis.
3.
Tighten the captive screws on the top and bottom of the fan tray faceplate to secure it in the chassis.
220 Copyright © 2019, Juniper Networks, Inc.
Chapter 19: Installing the T1600 Router into a Rack Without a Mechanical Lift
Figure 88: Reinstalling the Rear Fan Tray
Reinstalling the T1600 SCGs
To reinstall the SCGs (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Carefully align the sides of the SCG with the guides in the SCG slot.
3.
Grasp the SCG by its handle and slide it straight into the chassis until it contacts the midplane.
4.
Tighten the captive screws on the corners of the SCG faceplate.
5.
Repeat the procedure to reinstall the remaining SCG.
Copyright © 2019, Juniper Networks, Inc.
221
T1600 Core Router Hardware Guide
Figure 89: Reinstalling an SCG
Reinstalling the T1600 Control Boards
To reinstall the control boards (see
and
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Carefully align the sides of the control boards with the guides inside the chassis.
3.
Slide the control boards into the chassis, carefully ensuring that it is correctly aligned.
4.
Grasp both ejector handles and press them inward to seat the control board.
5.
Tighten the captive screws on the ejector handles, using a Phillips (+) screwdriver, number 2.
6.
Repeat the procedure to reinstall the remaining control board.
Figure 90: Reinstalling a T-CB
222 Copyright © 2019, Juniper Networks, Inc.
Chapter 19: Installing the T1600 Router into a Rack Without a Mechanical Lift
Figure 91: Reinstalling an LCC-CB
Reinstalling the T1600 SIBs
To reinstall the SIBs (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Place one hand underneath the SIB to support it. With the other hand, hold one of the ejector handles on the SIB faceplate.
3.
Carefully align the sides of the SIB with the guides inside the chassis.
4.
Slide the SIB into the chassis, carefully ensuring that it is correctly aligned.
5.
Grasp both ejector handles and press them inward to seat the SIB.
6.
Tighten the captive screws on the ejector handles.
7.
Repeat the procedure for each of the remaining SIBs.
Copyright © 2019, Juniper Networks, Inc.
223
T1600 Core Router Hardware Guide
Figure 92: Reinstalling a T1600–SIB
Reinstalling the T1600 Power Supplies
•
Reinstalling the T1600 DC Power Supplies on page 224
•
Reinstalling the T1600 AC Power Supplies on page 225
Reinstalling the T1600 DC Power Supplies
You can use this procedure to reinstall three-input 240-A DC power supplies, four-input
240-A DC power supplies, or six-input DC power supplies. Reinstall the lower power supply first, then the upper power supply. To reinstall the DC power supplies (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
For three-input 240-A DC power supplies or four-input 240-A DC power supplies, switch the circuit breakers on the power supply faceplate to the OFF position ( O ). For six-input DC power supplies, switch the power switch to the standby position.
3.
Using both hands, slide the power supply into the chassis until you feel resistance.
4.
Twist the ejector handles at the upper corners of the power supply faceplate clockwise until they stop.
5.
Tighten the captive screws at the lower corners of the power supply faceplate to secure the power supply in the chassis.
6.
Repeat the procedure for the upper power supply.
224 Copyright © 2019, Juniper Networks, Inc.
Chapter 19: Installing the T1600 Router into a Rack Without a Mechanical Lift
Figure 93: Reinstalling a Three-Input 240-A DC Power Supply
Figure 94: Reinstalling a T1600 Four-Input 240-A DC Power Supply
Reinstalling the T1600 AC Power Supplies
You can use this procedure to reinstall either the three-phase delta or wye AC power supplies. Reinstall the lower power supply first, then the upper power supply. To reinstall the AC power supplies (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Switch the power switch on the power supply faceplate to the standby position.
3.
Using both hands, slide the power supply into the chassis until you feel resistance.
4.
Twist the ejector handles at the upper corners of the power supply faceplate clockwise until they stop.
Copyright © 2019, Juniper Networks, Inc.
225
T1600 Core Router Hardware Guide
5.
Tighten the captive screws at the lower corners of the power supply faceplate to secure the power supply in the chassis.
6.
Repeat the procedure for the upper power supply.
Reinstalling the T1600 FPCs
To reinstall FPCs (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Using the list you created when you removed the FPCs, locate the slot in the FPC card cage in which you plan to install the FPC.
3.
Lift the FPC into place and carefully align first the bottom, then the top of the FPC with the guides inside the card cage. Be sure the FPC is right-side up, with the components on the right of the FPC.
CAUTION: When the FPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
4.
Slide the FPC all the way into the card cage until you feel resistance.
5.
Starting with the ejector handles on the FPC faceplate nearly horizontal, simultaneously turn both ejector handles clockwise to seat the FPC.
6.
If you are installing a Type 2 FPC or Type 3 FPC, tighten the screws inside the ejector handles to secure the FPC. Do not overtighten them.
7.
Repeat the procedure to reinstall each remaining FPC.
226 Copyright © 2019, Juniper Networks, Inc.
Chapter 19: Installing the T1600 Router into a Rack Without a Mechanical Lift
Figure 95: Reinstalling an FPC
T-1600 FPC4
Reinstalling T1600 Standard Front Fan Trays
To reinstall the standard front fan trays (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Grasp one of the fan trays by its handles and insert it straight into the chassis.
3.
Tighten the captive screw on each side of the fan tray faceplate to secure it in the chassis.
4.
Repeat the procedure to reinstall the remaining fan tray.
Copyright © 2019, Juniper Networks, Inc.
227
T1600 Core Router Hardware Guide
Figure 96: Reinstalling a Front Fan Tray
Reinstalling T1600 Quiet Fan Trays
To reinstall the quiet front fan trays:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Locate the fan tray labeled FAN-T-FTOP-S UPPER FANTRAY .
3.
Press the two latches located on each side of the fan tray up, and insert the upper front fan tray straight into the upper fan tray slot (see
).
4.
Tighten the captive screws on each side of the fan tray faceplate to secure it in the chassis.
5.
Locate a replacement quiet lower fan tray labeled FAN-T-FBOT-S LOWER FANTRAY .
6.
Press the two latches located on each side of the fan tray up, and insert the lower fan tray straight into the lower fan tray slot (see
7.
Tighten the captive screws on each side of the quiet lower front fan tray faceplate to secure it in the chassis.
8.
Unlock the front cable management system and lower it to the fully lowered position.
228 Copyright © 2019, Juniper Networks, Inc.
Chapter 19: Installing the T1600 Router into a Rack Without a Mechanical Lift
Figure 97: Reinstalling the Upper Front Quiet Fan Tray
Figure 98: Reinstalling the Lower Front Quiet Fan Tray
Reinstalling the T1600 Front Cable Management System
To reinstall the front cable management system:
1.
Position the front cable management system on the studs on the lower front of the chassis.
2.
Insert the nuts through the holes in the cable management system onto the studs on the chassis.
3.
Using a 3/8-in. nut driver, tighten the nuts securely.
Related
Documentation
•
Overview of Installing the T1600 Router on page 175
•
Overview of Installing a T1600 Router Without a Mechanical Lift on page 203
•
Removing Components from the T1600 Chassis on page 204
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Copyright © 2019, Juniper Networks, Inc.
229
T1600 Core Router Hardware Guide
230 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 20
Connecting the T1600 Router to Ground
•
Tools and Parts Required to Ground the T1600 Router on page 231
•
Connecting the T1600 Grounding Cable on page 232
Tools and Parts Required to Ground the T1600 Router
• Grounding cable (which you must provide)
• Grounding lug (provided with the router)
Figure 99: Grounding Lug
• M6 screws or UNC 1/4-20 screws
• Electrostatic discharge (ESD) grounding wrist strap
Related
Documentation
•
T1600 Chassis Description on page 21
•
T1600 Chassis Grounding Cable and Lug Specifications on page 140
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Copyright © 2019, Juniper Networks, Inc.
231
T1600 Core Router Hardware Guide
Connecting the T1600 Grounding Cable
You ground the router by connecting a grounding cable to earth ground and then attaching it to the chassis grounding points with two screws. You must provide the grounding cable
(a cable lug is supplied with the router). To connect the grounding cable (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Make sure that grounding surfaces are clean and brought to a bright finish before grounding connections are made.
3.
Connect the grounding cable to a proper earth ground.
4.
Verify that a licensed electrician has attached the cable lug provided with the router to the grounding cable.
5.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
6.
Place the grounding cable lug over the grounding points. The left pair is sized for M6 screws, and the right pair is sized for UNC 1/4-20 screws.
7.
Secure the grounding cable lug to the grounding points, first with the washers, then with the screws.
8.
Verify that the grounding cabling is correct, that the grounding cable does not touch or block access to router components, and that it does not drape where people could trip on it.
232 Copyright © 2019, Juniper Networks, Inc.
Figure 100: Connecting the Grounding Cable
Chapter 20: Connecting the T1600 Router to Ground
Grounding points
(on chassis)
Related
Documentation
•
T1600 Chassis Description on page 21
•
Tools and Parts Required to Ground the T1600 Router on page 231
•
T1600 Chassis Grounding Cable and Lug Specifications on page 140
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Copyright © 2019, Juniper Networks, Inc.
233
T1600 Core Router Hardware Guide
234 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 21
Connecting the T1600 Router to External
Devices
•
Overview of Connecting the T1600 Router to External Devices on page 235
•
Tools and Parts Required to Connect the T1600 Router to External Devices on page 236
•
Connecting the T1600 Router to a Management Console or Auxiliary Device on page 237
•
Connecting the T1600 Router to a Network for Out-of-Band Management on page 239
•
Connecting the T1600 Router to an External Alarm-Reporting Device on page 241
•
Connecting PIC Cables to the T1600 Router on page 242
Overview of Connecting the T1600 Router to External Devices
After you have grounded the T1600 Core Router, you can connect the following external devices:
• An external console or auxiliary device to the CONSOLE ports on the Connector Interface
Panel (CIP).
See
“Connecting the T1600 Router to a Management Console or Auxiliary Device” on page 237
• A laptop, modem, or other auxiliary device to the AUXILIARY ports on the CIP.
See
“Connecting the T1600 Router to a Management Console or Auxiliary Device” on page 237
.
• A management network to the ETHERNET ports on the CIP.
See
“Connecting the T1600 Router to a Network for Out-of-Band Management” on page 239
.
• An external alarm-reporting device to the alarm relay contacts on the CIP.
See
“Connecting the T1600 Router to an External Alarm-Reporting Device” on page 241
.
• An external clocking device to the EXTERNAL CLOCK INPUTS on the SONET clock generator with RJ-48 ports.
See Connecting the T1600 Router to an External Clocking Device .
Copyright © 2019, Juniper Networks, Inc.
235
T1600 Core Router Hardware Guide
NOTE: The external clock inputs on the SCG with DB-9 ports are not supported.
• A network connection to the ports on the PICs.
See
“Connecting PIC Cables to the T1600 Router” on page 242
.
Related
Documentation
•
Tools and Parts Required to Connect the T1600 Router to External Devices on page 236
Tools and Parts Required to Connect the T1600 Router to External Devices
To connect the router to management devices and PICs, you need the following tools and parts:
• Phillips (+) screwdrivers, numbers 1 and 2
• 2.5-mm flat-blade (-) screwdriver
• Wire cutters
• Electrostatic discharge (ESD) grounding wrist strap
Related
Documentation
•
Connecting DC Power to the T1600 Router (Three-Input 240-A DC Power Supplies or
Four-Input 240-A DC Power Supplies) on page 246
•
Connecting DC Power to the T1600 Router (Six 60-A Inputs to Six-Input DC Power
•
Connecting DC Power to the T1600 Router (Five 60-A Inputs to Six-Input DC Power
•
Powering Off the T1600 Router on page 266
•
T1600 Preventing Electrostatic Discharge Damage on page 588
236 Copyright © 2019, Juniper Networks, Inc.
Chapter 21: Connecting the T1600 Router to External Devices
Connecting the T1600 Router to a Management Console or Auxiliary Device
To use a system console to configure and manage the Routing Engine, connect it to the appropriate CONSOLE port on the CIP. To use a laptop, modem, or other auxiliary device, connect it to the appropriate AUXILIARY port on the CIP. Both ports accept an RS-232
(EIA-232) serial cable with a DB-9 female connector. One DB-9/DB-9 cable is provided with the router. To connect a device to the CONSOLE port, and another device to the
AUXILIARY port, you must supply another cable.
To connect a management console or auxiliary device:
1.
Turn off the power to the console or auxiliary device.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Connect one end (shown in
Figure 101 on page 238 ) of a serial cable with a DB-9 female
connector to the appropriate CONSOLE or AUXILIARY port (see
).
The ports labeled HOST 0 connect to the Routing Engine in the upper Routing Engine slot ( RE0 ), and the ports labeled HOST 1 connect to the Routing Engine in the lower
Routing Engine slot ( RE1 ).
NOTE:
For console devices, configure the serial port to the following values:
• Baud rate—9600
• Parity—N
• Data bits—8
• Stop bits—1
• Flow control—none
4.
Using a 2.5-mm flat-blade screwdriver, tighten the screws on the connector.
5.
Attach the other end of the cable to the console or auxiliary device.
Copyright © 2019, Juniper Networks, Inc.
237
T1600 Core Router Hardware Guide
Figure 101: Console and Auxiliary Serial Port Connector
Figure 102: Console and Auxiliary Ports on the CIP
238
Related
Documentation
•
T1600 Routing Engine Interface Cable and Wire Specifications on page 169
•
Overview of Connecting the T1600 Router to External Devices on page 235
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Copyright © 2019, Juniper Networks, Inc.
Chapter 21: Connecting the T1600 Router to External Devices
Connecting the T1600 Router to a Network for Out-of-Band Management
To connect the Routing Engine to a network for out-of-band management, connect an
Ethernet with RJ-45 connectors to the ETHERNET port on the CIP. One cable is provided with the router.
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Turn off the power to the management device.
3.
Plug one end of the Ethernet cable ( Figure 103 on page 239
shows the connector) in to the appropriate ETHERNET port on the CIP (see
Figure 104 on page 240 ). The ports
labeled HOST 0 connect to the Routing Engine in the upper Routing Engine slot ( RE0 ), and the ports labeled HOST 1 connect to the Routing Engine in the lower Routing
Engine slot ( RE1 ).
4.
Plug the other end of the cable into the network device.
Figure 103: Routing Engine Ethernet Cable Connector
Copyright © 2019, Juniper Networks, Inc.
239
T1600 Core Router Hardware Guide
Figure 104: ETHERNET Port on the CIP
HOST
0
ETHERNET
ACT 0
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
HOST
1
ETHERNET
ACT 1
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
RED ALARM
NC
C
NO
NC
C
NO
YELLOW
ALARM
Related
Documentation
•
T1600 Routing Engine Interface Cable and Wire Specifications on page 169
•
Overview of Connecting the T1600 Router to External Devices on page 235
•
T1600 Preventing Electrostatic Discharge Damage on page 588
240 Copyright © 2019, Juniper Networks, Inc.
Chapter 21: Connecting the T1600 Router to External Devices
Connecting the T1600 Router to an External Alarm-Reporting Device
To connect the router to external alarm-reporting devices, attach wires to the RED ALARM and YELLOW ALARM relay contacts on the CIP. A system condition that triggers the red or yellow alarm LED on the craft interface also activates the corresponding alarm relay contact.
The terminal blocks that plug into the alarm relay contacts are supplied with the router.
They accept wire of any gauge between 28-AWG and 14-AWG (0.08 and 2.08 mm
2
), which is not provided. Use the gauge of wire appropriate for the external device you are connecting.
To connect an external device to an alarm relay contact:
1.
Prepare the required length of wire with gauge between 28-AWG and 14-AWG (0.08
and 2.08 mm
2
).
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
While the terminal block is not plugged into the relay contact, use a 2.5-mm flat-blade screwdriver to loosen the small screws on its side. With the small screws on its side facing left, insert wires into the slots in the front of the block based on the wiring for the external device. Tighten the screws to secure the wire.
4.
Orient the terminal block according to the labels to the left of the appropriate relay contact ( NC means “normally closed, C means “common,” and ( NO means “normally open”).
5.
Plug the terminal block into the relay contact and use a 2.5-mm flat-blade screwdriver to tighten the screws on the face of the block.
6.
Attach the other end of the wires to the external device.
If attaching a reporting device for the other kind of alarm, repeat the procedure.
Related
Documentation
•
Overview of Connecting the T1600 Router to External Devices on page 235
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Replacing the T1600 Alarm Relay Wires on page 320
Copyright © 2019, Juniper Networks, Inc.
241
T1600 Core Router Hardware Guide
Connecting PIC Cables to the T1600 Router
The router supports PICs that use various kinds of network cable, including multimode and single-mode fiber-optic cable. For information about the type of cable used by each
PIC, see the interface module reference for your device.
You connect PICs to the network by plugging in network cable. To connect cable to the
PICs (see
Figure 105 on page 243 , which shows a fiber-optic PIC):
1.
Have ready a length of the type of cable used by the PIC. For cable specifications, see
Determining Transceiver Support and Specifications for M Series and T Series Routers in the interface module reference for your device.
2.
If the PIC cable connector port is covered by a rubber safety plug, remove the plug.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
3.
Insert the cable connector into the cable connector port on the PIC faceplate.
4.
Arrange the cable in the cable management system to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
242 Copyright © 2019, Juniper Networks, Inc.
Figure 105: Attaching a Cable to a PIC
Chapter 21: Connecting the T1600 Router to External Devices
PIC
Fiber-optic cable
Related
Documentation
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Installing a T1600 PIC Cable on page 409
•
Maintaining T1600 PICs and PIC Cables on page 523
•
Replacing a T1600 PIC Cable on page 408
Copyright © 2019, Juniper Networks, Inc.
243
T1600 Core Router Hardware Guide
244 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 22
Providing Power to the T1600 Router
•
Tools and Parts Required to Provide Power to the T1600 Router on page 245
•
Connecting DC Power to the T1600 Router (Three-Input 240-A DC Power Supplies or
Four-Input 240-A DC Power Supplies) on page 246
•
Connecting DC Power to the T1600 Router (Six 60-A Inputs to Six-Input DC Power
•
Connecting DC Power to the T1600 Router (Five 60-A Inputs to Six-Input DC Power
•
Powering On the DC-Powered T1600 Router on page 257
•
Connecting AC Power to a T1600 Router with Three-Phase Delta AC Power
•
Connecting AC Power to a T1600 Router with Three-Phase Wye AC Power
•
Powering On the AC-Powered T1600 Router on page 264
•
Powering Off the T1600 Router on page 266
Tools and Parts Required to Provide Power to the T1600 Router
• DC-powered routers: 7/16-in. (11 mm) hexagonal-head external drive nut driver, with a torque range between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm), for tightening nuts to terminal studs on each power supply on a DC-powered router.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
• AC-powered router:
• Phillips (+) screwdriver, number 2 to access the metal AC wiring compartment
• 1/4-in. slotted screwdriver to attach the ground wire and input terminal wires of the
AC power cord.
• Electrostatic discharge (ESD) grounding wrist strap
Copyright © 2019, Juniper Networks, Inc.
245
T1600 Core Router Hardware Guide
Related
Documentation
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 General Electrical Safety Guidelines on page 613
•
T1600 DC Power System Electrical Specifications on page 145
•
T1600 AC Power Requirements on page 157
Connecting DC Power to the T1600 Router (Three-Input 240-A DC Power Supplies or
Four-Input 240-A DC Power Supplies)
You connect DC power to the router by attaching power cables from the DC power sources to the terminal studs on the power supply faceplates. You must provide power cables
(the cable lugs are supplied with the router).
CAUTION: All inputs on the DC power supply in slot PEM0 must be powered by dedicated power feeds derived from feed A, and all inputs on the DC power supply in slot PEM1 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed A/B feed redundancy for the system.
To connect the DC source power cables to the router, follow this procedure for each DC power supply:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
Switch off the customer site circuit breakers. Ensure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cable leads might become active during installation.
2.
Verify that a licensed electrician has attached the cable lugs provided with the router to the power cables.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
Switch the circuit breakers on the power supply faceplate to the OFF position ( O ).
5.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
6.
Remove the nut and washer from each power terminal stud. If no washers and nuts are already installed, they should be in the accessory box.
7.
Attach the lugs on the DC source power cables to the terminal studs. Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in.
246 Copyright © 2019, Juniper Networks, Inc.
Chapter 22: Providing Power to the T1600 Router
(11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in.
(2.8 Nm) of torque to each nut.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
a.
Attach the positive (+) DC source power cable lugs to the RTN (return) terminals.
b.
Attach the negative (–) DC source power cable lugs to the –48V (input) terminals.
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
8.
Loosen the captive screw or screws on the cable restraint on the right edge of the power supply faceplate (using a Phillips (+) screwdriver, number 2).
9.
Route the positive and negative DC power cables through the cable restraint.
10.
Tighten the cable restraint captive screw or screws to hold the power cables in place.
11.
Verify that the power cabling is correct, that the power cables are not touching or blocking access to router components, and that they do not drape where people could trip on them.
12.
Replace the clear plastic cover over the terminal studs on the faceplate.
Copyright © 2019, Juniper Networks, Inc.
247
T1600 Core Router Hardware Guide
Figure 106: Connecting Power to the Three-Input 240-A DC Power Supply
248 Copyright © 2019, Juniper Networks, Inc.
Chapter 22: Providing Power to the T1600 Router
Figure 107: Connecting Power to the Four-Input 240-A DC Power Supply
Cable lug Terminal studs
Locking washer
Nut
Related
Documentation
•
T1600 Power System Description on page 113
•
T1600 Three-Input 240-A DC Power Supply Description on page 114
•
T1600 Four-Input 240-A DC Power Supply Description on page 117
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 General Electrical Safety Guidelines on page 613
•
T1600 DC Power Cables and Lugs on page 152
Connecting DC Power to the T1600 Router (Six 60-A Inputs to Six-Input DC Power
Supplies)
You connect DC power to the router by attaching power cables from the DC power sources to the terminal studs on the power supply faceplates. You must provide power cables
(the cable lugs are supplied with the router).
CAUTION: All connected inputs on the DC power supply in slot PEM0 must be powered by dedicated power feeds derived from feed A, and all connected inputs on the DC power supply in slot PEM1 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed A/B feed redundancy for the system.
Copyright © 2019, Juniper Networks, Inc.
249
T1600 Core Router Hardware Guide
NOTE: We recommend that the positive (+) DC source power cables for the
RTN (return) terminals be 2.6 in. (6.6 cm) longer than the negative (–) DC source power cables for the –48 V (input) terminals.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
To connect DC source power cables to the router, follow this procedure for each DC power supply:
1.
Verify that a properly rated customer site circuit breaker for each DC power cable has been installed. See the DC power electrical safety guidelines for your router for more information.
2.
Switch off the customer site circuit breakers. Ensure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cable leads might become active during installation.
3.
Verify that a licensed electrician has attached appropriate cable lugs to the DC power cables. See the DC power cable and lug specifications for your router for more information.
4.
Switch the power switch on the power supply faceplate to the standby position.
5.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
6.
Remove the nut and washer from each power terminal stud to be connected. If no washers and nuts are already installed, they should be in the accessory box.
7.
Remove the captive screws on all three cable restraints on the right edge of the power supply faceplate (using a Phillips (+) screwdriver, number 2).
250 Copyright © 2019, Juniper Networks, Inc.
Chapter 22: Providing Power to the T1600 Router
8.
Route the negative (–) DC source power cables for INPUT 0 , INPUT 1 , INPUT 3 , and
INPUT 4 over the smallest cable restraint on the far right. The cable restraint is marked as follows top to bottom: INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 .
NOTE: You must route the cables in the locations as marked to be able to replace the clear plastic cover over the terminal studs.
Figure 108: Connecting DC Power Cables
Cable lug
Terminal studs
Locking washer
Nut
Attach the negative (–) DC source power cable lugs INPUT 0 , INPUT 1 , INPUT 3 , and
INPUT 4 to the –48 V (input) terminals on the right. Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
Figure 109: Connecting Negative (–) DC Power Cables to INPUT 0, INPUT 1, INPUT 3, and INPUT 4
9.
Replace the smallest cable restraint on the far right, and tighten the captive screw to hold the power cables for INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 in place.
10.
Route the negative (–) DC source power cables for INPUT 2 and INPUT 5 through the middle cable restraint. The middle cable restraint is marked as follows from top to bottom: INPUT 2 , RTN 2 , RTN 5 , and INPUT 5 .
NOTE: You must route the cables in the locations as marked to be able to replace the clear plastic cover over the terminal studs.
Copyright © 2019, Juniper Networks, Inc.
251
T1600 Core Router Hardware Guide
Attach the negative (–) DC source power cable lugs to the –48 V (input) terminals on the right. Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
Figure 110: Connecting Negative (–) DC Power Cables to INPUT 2 and INPUT 5
252
11.
Route the positive (+) DC source power cables for RTN 2 and RTN 5 over the middle cable restraint. The middle cable restraint is marked as follows from top to bottom:
INPUT 2 , RTN 2 , RTN 5 , and INPUT 5 .
NOTE: You must route the cables as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the positive (+) DC source power cable lugs RTN 2 and RTN 5 to the RTN
(return) terminals on the left. Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts.
Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
12.
Replace the middle cable restraint, and tighten the captive screw to hold the power cables for INPUT 2 , INPUT 5 , RTN 2 , and RTN 5 in place.
13.
Route the positive (+) DC source power cables for RTN 0 , RTN 1 , RTN 3 , and RTN 4 over the largest cable restraint on the left. The left cable restraint is marked as follows from top to bottom: RTN 0 , RTN 1 , RTN 3 , and RTN 4 .
NOTE: You must route the cables as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the positive (+) DC source power cable lugs to the RTN 0 , RTN 1 , RTN 3 , and
RTN 4 terminals on the left. Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
Copyright © 2019, Juniper Networks, Inc.
Chapter 22: Providing Power to the T1600 Router
14.
Replace the left cable restraint, and tighten the captive screw to hold the power cables for RTN 0 , RTN 1 , RTN 3 , and RTN 4 in place.
Figure 111: Connecting Positive (+) DC Power Cables to RTN 2, RTN 5, RTN 0, RTN 1,
RTN 3, and RTN 4
15.
Verify that the power cabling is correct, that the power cables are not touching or blocking access to router components, and that they do not drape where people could trip on them.
16.
Replace the clear plastic cover over the terminal studs on the faceplate.
Related
Documentation
•
Tools and Parts Required to Provide Power to the T1600 Router on page 245
•
Connecting DC Power to the T1600 Router (Five 60-A Inputs to Six-Input DC Power
•
Powering On the DC-Powered T1600 Router on page 257
•
Configuring DC Power on a T1600 Router on page 272
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 General Electrical Safety Guidelines on page 613
Connecting DC Power to the T1600 Router (Five 60-A Inputs to Six-Input DC Power
Supplies)
You connect DC power to the router by attaching power cables from the DC power sources to the terminal studs on the power supply faceplates. You must provide power cables
(the cable lugs are supplied with the router).
CAUTION: Do not use a terminal jumper for 60-A DC power cables. Using a terminal jumper is not supported for this procedure. Doing so will cause a short across the inputs and trip your external circuit breaker.
Copyright © 2019, Juniper Networks, Inc.
253
T1600 Core Router Hardware Guide
254
CAUTION: All connected inputs on the DC power supply in slot PEM0 must be powered by dedicated power feeds derived from feed A, and all connected inputs on the DC power supply in slot PEM1 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed A/B feed redundancy for the system.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
NOTE: We recommend that the positive (+) DC source power cables to be connected to the RTN (return) terminals be 2.6 in. (6.6 cm) longer than the negative (–) DC source power cables to be connected to the –48 V (input) terminals.
To connect five 60-A DC source power cables to the router, follow this procedure for each DC power supply:
1.
Verify that a properly rated customer site circuit breaker for each DC power cable has been installed. See the DC power electrical safety guidelines for your router for more information.
2.
Switch off the customer site circuit breakers. Ensure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cable leads might become active during installation.
3.
Verify that a licensed electrician has attached appropriate cable lugs to the DC power cables. See the DC power cable and lug specifications for your router for more information.
4.
Switch the power switch on the power supply faceplate to the standby position.
5.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
Copyright © 2019, Juniper Networks, Inc.
Chapter 22: Providing Power to the T1600 Router
6.
Remove the nut and washer from each power terminal stud to be connected. If no washers and nuts are already installed, they should be in the accessory box.
7.
Remove the captive screws on all three cable restraints on the right edge of the power supply faceplate (using a Phillips (+) screwdriver, number 2).
8.
Route the negative (–) DC source power cables for INPUT 0 , INPUT 1 , INPUT 3 , and
INPUT 4 , over the smallest cable restraint on the far right. The cable restraint is marked as follows top to bottom: INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 ,
NOTE: You must route the cables in the locations as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the negative (–) DC source power cable lugs to the –48V (input) terminals on the right: INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 . Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
Figure 112: Connecting DC Power Cables
Cable lug
Terminal studs
Locking washer
Nut
Figure 113: Connecting Negative (–) DC Power Cables to INPUT 0, INPUT 1, INPUT 3, and
INPUT 4
9.
Replace the smallest cable restraint on the far right, and tighten the captive screw to hold the power cables for INPUT 0 , INPUT 1 , INPUT 3 , and INPUT 4 in place.
Copyright © 2019, Juniper Networks, Inc.
255
T1600 Core Router Hardware Guide
10.
Route the negative (–) DC source power cables for INPUT 2 , through the middle cable restraint. The middle cable restraint is marked as follows from top to bottom: INPUT
2 , RTN 2 , RTN 5 , and INPUT 5 .
NOTE: You must route the cable in the location as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the negative (–) DC source power cable lugs to the INPUT 2 –48 V (input) terminal on the right. Secure the cable lug to the terminal studs, first with the washer, then with the nut. Using a 7/16-in. (11 mm) nut driver, tighten the nut. Apply between
23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
Figure 114: Connecting Negative (–) DC Power Cable to INPUT 2
256
11.
Route the positive (+) DC source power cables for RTN 2 over the middle cable restraint. The middle cable restraint is marked as follows from top to bottom: INPUT
2 , RTN 2 , RTN 5 , and INPUT 5 ,
NOTE: You must route the cables as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the positive (+) DC source power cable lug to the RTN 2 (return) terminal on the left. Secure the cable lug to the terminal stud, first with the washer, then with the nut. Using a 7/16-in. (11 mm) nut driver, tighten the nuts. Apply between 23 lb-in. (2.6
Nm) and 25 lb-in. (2.8 Nm) of torque to the nut.
12.
Replace the middle cable restraint, and tighten the captive screw to hold the power cables for INPUT 2 and RTN 2 in place.
13.
Route the positive (+) DC source power cables for RTN 0 , RTN 1 , RTN 3 , and RTN 4 over the largest cable restraint on the left. The left cable restraint is marked as follows from top to bottom RTN 0 , RTN 1 , RTN 3 , and RTN 4 ,
Copyright © 2019, Juniper Networks, Inc.
Chapter 22: Providing Power to the T1600 Router
NOTE: You must route the cables as marked to be able to replace the clear plastic cover over the terminal studs.
Attach the positive (+) DC source power cable lugs to the RTN terminals on the left:
RTN 0 , RTN 1 , RTN 3 , and RTN 4 . Secure the cable lugs to the terminal studs, first with the washers, then with the nuts. Using a 7/16-in. (11 mm) nut driver, tighten the nuts.
Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
14.
Replace the left cable restraint, and tighten the captive screw to hold the power cables for RTN 0 , RTN 1 , RTN 3 , and RTN 4 in place.
Figure 115: Connecting Positive (+) DC Power Cable to RTN 2, RTN 0, RTN 1, RTN 3, RTN 4
15.
Verify that the power cabling is correct, that the power cables are not touching or blocking access to router components, and that they do not drape where people could trip on them.
16.
Replace the clear plastic cover over the terminal studs on the faceplate.
Related
Documentation
•
Tools and Parts Required to Provide Power to the T1600 Router on page 245
•
Connecting DC Power to the T1600 Router (Six 60-A Inputs to Six-Input DC Power
•
Powering On the DC-Powered T1600 Router on page 257
•
Configuring DC Power on a T1600 Router on page 272
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 General Electrical Safety Guidelines on page 613
Powering On the DC-Powered T1600 Router
You can use this procedure for a T1600 router with three-input 240-A DC power supplies, four-input 240-A DC power supplies, or six-input DC power supplies.
Copyright © 2019, Juniper Networks, Inc.
257
T1600 Core Router Hardware Guide
To power on the DC-powered router:
1.
Verify that the power supplies are fully inserted in the chassis and that the captive screws on their faceplates are tightened.
2.
Verify that the source power cables are connected to the appropriate terminal: the positive (+) source cable to the return terminal (labeled RTN ) and the negative (–) source cable to the input terminal (labeled –48V ).
3.
Verify that an external management device is connected to one of the Routing Engine ports on the CIP ( AUXILIARY , CONSOLE , or ETHERNET ).
NOTE: If you are powering on the router for the first time, the ETHERNET port does not function until after the initial configuration procedure.
4.
Turn on the power to the external management device.
5.
Switch on the dedicated customer site circuit breakers to provide power to the DC power cables. Follow your site’s procedures.
6.
Verify that the INPUT PRESENT LED for each input on the DC power supply faceplate is lit steadily green, indicating that the inputs are receiving power.
7.
For three-input 240-A DC power supplies and four-input 240-A DC power supplies, switch the circuit breakers on one of the power supplies to the ON position ( | ).
NOTE: If the router is completely powered off when you power on the power supply, the Routing Engine boots as the power supply completes its startup sequence. If the Routing Engine finishes booting and you need to power off the router again, see the procedure for powering off the router.
After powering on a power supply, wait at least 60 seconds before turning it off.
For six-input power supplies, switch the power switch on one of the power supplies to the ON position ( — ). The DC OK LED blinks momentarily, then lights steadily.
8.
For three-input 240-A DC power supplies and four-input 240-A DC power supplies, verify that the CB ON LEDs on the DC power supply faceplate are lit steadily, indicating that the circuit breakers are on.
For six-input power supplies, skip this step.
258 Copyright © 2019, Juniper Networks, Inc.
Chapter 22: Providing Power to the T1600 Router
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the output status LEDs on the power supply, the command output, and messages on the LCD on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
If any of the output status LEDs does not light steadily after 60 seconds, repeat the procedure to connect the DC cables.
If you continue to have problems, see the replacement procedure for the power supply.
•
Replacing a T1600 Three-Input 240-A DC Power Supply on page 414
•
Replacing a T1600 Four-Input 240-A DC Power Supply on page 425
•
Replacing a T1600 Six-Input DC Power Supply on page 440
9.
On the external management device connected to the Routing Engine, monitor the startup process to verify that the router has booted properly.
10.
Verify that the DC OK LED on the DC power supply faceplate is lit steadily, indicating that power supply is correctly installed and functioning properly. The DC OK LED blinks momentarily, then lights steadily.
11.
Repeat the procedure for the other power supply.
Related
Documentation
•
Overview of Connecting the T1600 Router to External Devices on page 235
•
Connecting the T1600 Router to a Management Console or Auxiliary Device on page 237
•
Connecting DC Power to the T1600 Router (Three-Input 240-A DC Power Supplies or
Four-Input 240-A DC Power Supplies) on page 246
•
Connecting DC Power to the T1600 Router (Six 60-A Inputs to Six-Input DC Power
•
Connecting DC Power to the T1600 Router (Five 60-A Inputs to Six-Input DC Power
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 General Electrical Safety Guidelines on page 613
•
T1600 DC Power System Electrical Specifications on page 145
Connecting AC Power to a T1600 Router with Three-Phase Delta AC Power Supplies
You connect AC power to the router with three-phase delta AC power supplies by connecting the AC power cord from an AC power supply to an AC power source.
Copyright © 2019, Juniper Networks, Inc.
259
T1600 Core Router Hardware Guide
To connect an AC power cord to an AC power source:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Switch off the customer site circuit breakers. Ensure that the voltage across the AC power source is 0 V and that there is no chance that the voltage might become active during installation.
3.
Detach the ESD grounding strap from the approved site ESD grounding point, and connect the strap to one of the ESD points on the chassis.
4.
Switch the power switch on the power supply faceplate to the standby position.
5.
Using a number 2 Phillips (+) screwdriver, unscrew the two captive screws located on the right side of the metal AC wiring compartment.
6.
Open the metal door of the metal AC wiring compartment.
7.
Unscrew the retaining nut from the AC power cord.
8.
Place the retaining nut inside the metal wiring compartment.
9.
Put the wires of the AC power cord through the hole of the metal wiring compartment.
10.
Screw the retaining nut onto the AC power cord to secure it to the metal wiring compartment.
260 Copyright © 2019, Juniper Networks, Inc.
Chapter 22: Providing Power to the T1600 Router
11.
Connect the wires to the AC terminal block on the three-phase delta AC power supply
(
). Loosen the input terminal or grounding point screw, insert each wire into the grounding point or input terminal, and tighten the screw.
NOTE: The terminal connections have either slotted screws or hex screws.
Use a 1/4-in. slotted screwdriver for the slotted screws. Use a 5/32-in
(4-mm) Allen wrench for the 5/16-in hex screws.
a.
Insert the wire labeled GND into the grounding point labeled GND .
b.
Insert the wire labeled L1 into the L1 input terminal.
c.
Insert the wire labeled L2 into the L2 input terminal.
d.
Insert the wire labeled L3 into the L3 input terminal.
Figure 116: Connecting Power to a Three-Phase Delta AC Power Supply
L1 L2 L3
L1 L2 L3
NOTE: The color of each AC power wire might vary.
12.
Verify that the power cable connections are correct.
Copyright © 2019, Juniper Networks, Inc.
261
T1600 Core Router Hardware Guide
13.
Using a number 2 Phillips (+) screwdriver, tighten the two captive screws on the metal
AC wiring compartment.
14.
Use the provided plastic cable tie to fasten the AC power cord to the power supply.
15.
Verify that the AC power cord is not touching or blocking access to router components, and that it does not drape where people could trip on it.
16.
Repeat the procedure for the other three-phase delta AC power supply.
Related
Documentation
•
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
Powering On the AC-Powered T1600 Router on page 264
• T1600 AC Power Electrical Safety Guidelines
•
T1600 AC Power Cord Specifications on page 159
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Connecting AC Power to a T1600 Router with Three-Phase Wye AC Power Supplies
To connect an AC power cord:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Switch off the customer site circuit breakers. Ensure that the voltage across the AC power source is 0 V and that there is no chance that the voltage might become active during installation.
3.
Detach the ESD grounding strap from the approved site ESD grounding point, and connect the strap to one of the ESD points on the chassis.
4.
Switch the power switch on the power supply faceplate to the standby position.
5.
Using a number 2 Phillips (+) screwdriver, loosen the two captive screws on the metal
AC wiring compartment.
6.
Open the metal door of the metal AC wiring compartment.
7.
Unscrew the retaining nut from the AC power cord.
8.
Place the retaining nut inside the metal wiring compartment.
9.
Put the wires of the AC power cord through the hole of the metal wiring compartment.
262 Copyright © 2019, Juniper Networks, Inc.
Chapter 22: Providing Power to the T1600 Router
10.
Screw the retaining nut onto the AC power cord to secure it to the metal wiring compartment.
11.
Connect the wires to the AC terminal block on the three-phase wye AC power supply
(
Figure 117 on page 263 ). Loosen each of the input terminals or grounding point screws,
insert each wire into the grounding point or input terminal, and tighten the screw.
NOTE: The terminal connections have either slotted screws or hex screws.
Use a 1/4-in. slotted screwdriver for the slotted screws. Use a 5/32-in
(4-mm) Allen wrench for the 5/16-in hex screws.
a.
Insert the wire labeled GND into the grounding point labeled GND .
b.
Insert the wire labeled L1 into the L1 input terminal.
c.
Insert the wire labeled L2 into the L2 input terminal.
d.
Insert the wire labeled L3 into the L3 input terminal.
e.
Insert the wire labeled N into the N input terminal
Figure 117: Connecting Power to the Three-Phase Wye AC Power Supply
L1 L2 L3 N
12.
Verify that the power cable connections are correct.
13.
Using a number 2 Phillips (+) screwdriver, tighten the two captive screws on the metal
AC wiring compartment.
14.
Use the provided plastic cable tie to fasten the AC power cord to the power supply.
Copyright © 2019, Juniper Networks, Inc.
263
T1600 Core Router Hardware Guide
Figure 118: Fastening the AC Power Cord to the Power Supply
15.
Verify that the AC power cord is not touching or blocking access to router components, and that it does not drape where people could trip on it.
16.
Repeat the procedure for the other three-phase wye AC power supply.
Related
Documentation
•
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
Powering On the AC-Powered T1600 Router on page 264
•
T1600 General Electrical Safety Guidelines on page 613
• T1600 AC Power Electrical Safety Guidelines
•
T1600 AC Power Cord Specifications on page 159
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Powering On the AC-Powered T1600 Router
You can use this procedure for a router with either three-phase delta AC power supplies or three-phase wye AC power supplies. To power on the AC-powered router:
1.
Verify that the power supplies are fully inserted in the chassis and that the captive screws on their faceplates are tightened.
2.
Verify that the AC power cords are connected correctly.
3.
Verify that an external management device is connected to one of the Routing Engine ports on the CIP ( AUXILIARY or CONSOLE ).
NOTE: The management Ethernet port will not be functional until you have completed the initial configuration.
264 Copyright © 2019, Juniper Networks, Inc.
Chapter 22: Providing Power to the T1600 Router
4.
Turn on the power to the external management device.
5.
Switch on the dedicated customer site circuit breakers to provide power to the AC power cables. Follow your site’s procedures.
6.
Verify that the AC OK LED on both AC power supply faceplates are lit steadily green, indicating that the power supplies are receiving power.
7.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
8.
Switch the power switch on one of the power supplies to the ON position ( | ). The DC
OK LED blinks momentarily, then lights steadily.
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the output status LEDs on the power supply, the command output, and messages on the LCD on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
9.
Verify that the DC OK LED on the AC power supply faceplate is lit steadily, indicating that power supply is correctly installed, functioning properly, and providing power to the DC outputs.
10.
On the external management device connected to the Routing Engine, monitor the startup process to verify that the system has booted properly.
NOTE: If the system is completely powered off when you power on the power supply, the Routing Engine boots as the power supply completes its startup sequence. If the Routing Engine finishes booting, you must power off the router before powering it on again. After powering on a power supply, wait at least 60 seconds before turning it off. After powering off a power supply, wait at least 60 seconds before turning it back on.
Related
Documentation
•
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
Overview of Connecting the T1600 Router to External Devices on page 235
•
Connecting the T1600 Router to a Management Console or Auxiliary Device on page 237
•
Connecting AC Power to a T1600 Router with Three-Phase Delta AC Power Supplies on page 259
Copyright © 2019, Juniper Networks, Inc.
265
T1600 Core Router Hardware Guide
•
Connecting AC Power to a T1600 Router with Three-Phase Wye AC Power Supplies on page 262
•
Powering Off the T1600 Router on page 266
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 General Electrical Safety Guidelines on page 613
• T1600 AC Power Electrical Safety Guidelines
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Powering Off the T1600 Router
To power off a T320 router:
1.
On the external management device connected to the Routing Engine, issue the request system halt both-routing-engines operational mode command. The command shuts down both Routing Engines cleanly, so their state information is preserved. (If the router contains only one Routing Engine, issue the request system halt command.) user@host> request system halt both-routing-engines
For more information about these commands, see request system halt .
2.
Wait until a message appears on the console confirming that the operating system has halted.
Halt the system ? [yes,no] (no) yes
*** FINAL System shutdown message from root@section2 ***
System going down IMMEDIATELY
Terminated
...
syncing disks... 11 8 done
The operating system has halted.
Please press any key to reboot.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
Switch the circuit breakers on each power supply faceplate to the off position ( O ).
Related
Documentation
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 General Electrical Safety Guidelines on page 613
266 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 23
Configuring the JUNOS Software
•
Initially Configuring the T1600 Router on page 267
•
Configuring DC Power on a T1600 Router on page 272
Initially Configuring the T1600 Router
The T1600 Core Router is shipped with Junos OS preinstalled and ready to be configured when the T1600 router is powered on. These procedures connect a router to the network but do not enable it to forward traffic. For complete information about enabling the router to forward traffic, including examples, see the Junos OS configuration guides.
You configure the router by issuing Junos OS command-line interface (CLI) commands, either on a console device attached to the CONSOLE port on the CIP, or over a telnet connection to a network connected to the ETHERNET port on the CIP.
NOTE: These procedures enable you to use the ETHERNET management port. For the initial configuration, use a device attached to the CONSOLE port on the CIP.
For more information about the commands in this procedure see the Junos OS
Administration Library .
1.
Preparing to Configure the T1600 Router on page 267
2.
Entering Configuration Mode on page 268
3.
Configuring User Accounts and Passwords on page 268
4.
Configuring System Attributes on page 269
5.
Committing the Configuration on page 270
Preparing to Configure the T1600 Router
Gather the following information before configuring the router:
• Name the router will use on the network
• Domain name the router will use
• IP address and prefix length information for the Ethernet interface
Copyright © 2019, Juniper Networks, Inc.
267
T1600 Core Router Hardware Guide
• IP address of a default router
• IP address of a DNS server
• Password for the root user
Entering Configuration Mode
1.
Verify that the network device is powered on.
2.
Log in as the root user. There is no password.
Amnesiac <ttyd0> login: root
3.
Start the CLI.
root@% cli root>
4.
Enter configuration mode.
root> configure
Entering configuration mode.
[edit] root#
Configuring User Accounts and Passwords
For information about using an encrypted password or an SSH public key string (DSA or
RSA), see Configuring the Root Password and authentication (Login) .
1.
Add a password to the root administration user account. Enter a cleartext password.
[edit] root@host# set system root-authentication plain-text-password
New password: password
Retype new password: password
2.
Create a management console user account.
[edit] root@host# set system login user user-name authentication plain-text-password
New Password: password
Retype new password: password
3.
Set the user account class to super-user .
[edit]
268 Copyright © 2019, Juniper Networks, Inc.
Chapter 23: Configuring the JUNOS Software root@host# set system login user user-name class super-user
Configuring System Attributes
For more information on configuring the backup routing and static routes, see the Junos
OS Administration Library .
1.
Configure the name of the router. If the name includes spaces, enclose the name in quotation marks (“ ”).
[edit] root@host# set system host-name host-name
NOTE: The DNS server does not use the hostname to resolve to the correct
IP address. This hostname is used to display the name of the routing engine in the CLI. For example, this hostname shows on the command-line prompt when the user is logged on to the CLI: user-name @ host-name >
2.
Configure the IP address of the DNS server.
[edit] root# set system name-server address
3.
Configure the router’s domain name.
[edit] root@# set system domain-name domain-name
4.
Configure the IP address and prefix length for the router’s management Ethernet interface.
NOTE: The RE-C1800 Routing Engine ( RE-DUO-1800 ) does not support the fxp0 interface or the fxp1 and fxp2 internal Ethernet interfaces. Use the em0 interface for the RE-C1800 Routing Engine, and fxp0 interface for all other Routing Engines supported for the router.
[edit] root@# set interfaces fxp0 unit 0 family inet address address/prefix-length
[edit] root@# set interfaces em0 unit 0 family inet address address/prefix-length
Copyright © 2019, Juniper Networks, Inc.
269
T1600 Core Router Hardware Guide
5.
Configure the IP address of a backup routing engine. The backup routing engine is used while the local router is booting and if the routing process fails to start. After the routing process starts, the backup routing engine address is removed from the local routing and forwarding tables.
[edit] root# set system backup-router address
6.
(Optional) Configure the static routes to remote subnets with access to the management port. Access to the management port is limited to the local subnet. To access the management port from a remote subnet, you must add a static route to that subnet within the routing table.
[edit] root# set routing-options static route remote-subnet next-hop destination-IP
retain no-readvertise
7.
Configure the telnet service at the [edit system services] hierarchy level.
[edit] set system services telnet
Committing the Configuration
For a chassis with two Routing Engines, commit the configuration changes to both Routing
Engines. When you issue the commit synchronize command, the configuration is shared between both Routing Engines and committed on both Routing Engines simultaneously.
For a chassis with only one Routing Engine, use the commit command instead of the commit synchronize command.
1.
Display the configuration to verify that it is correct.
[edit] root@host# show
## Last changed: 2008-10-17 18:32:25 UTC version 9.1R1.8; groups {
re0 {
system {
host-name host-re0;
}
interfaces {
fxp0 {
unit 0 {
family inet {
address 192.168.69.155/21;
}
}
}
}
}
re1 {
system {
270 Copyright © 2019, Juniper Networks, Inc.
Copyright © 2019, Juniper Networks, Inc.
Chapter 23: Configuring the JUNOS Software
host-name host-re1;
}
interfaces {
em0 {
unit 0 {
family inet {
address 192.168.70.72/21;
}
}
}
}
}
global;
} apply-groups [ re0 re1 ]; system {
domain-name example.com;
backup-router 192.168.71.254;
root-authentication {
encrypted-password "$ABC123"; ## SECRET-DATA
}
name-server {
192.168.1.1;
}
login {
user user {
uid 2001;
class super-user;
authentication {
encrypted-password "$ABC123"; ## SECRET-DATA
}
}
}
services {
telnet;
}
syslog {
user * {
any emergency;
}
file messages {
any notice;
authorization info;
}
file interactive-commands {
interactive-commands any;
}
}
} routing-options {
static {
/* corporate office */
route 172.16.0.0/12 {
next-hop 192.168.71.254;
retain;
no-readvertise;
}
}
}
271
T1600 Core Router Hardware Guide
2.
Commit the configuration to activate it, and synchronize the configuration. The commit synchronize command commits this new configuration on both Routing Engines simultaneously.
[edit] root# commit synchronize re0: configuration check succeeds re1: commit complete re0: commit complete
If you receive an error message after you issue the commit statement, you can review the configuration using the show command to find the errors in your configuration.
You can delete incorrect entries using the delete command. For example, to delete a hostname from the configuration, issue the following command:
[edit] root# delete system host-name hostname
3.
(Optional) Configure additional properties by adding the necessary configuration statements. Then commit the changes to activate them.
[edit] root@host# commit synchronize
4.
Exit configuration mode.
[edit] root@host# exit
Exiting configuration mode root>
Related
Documentation
•
T1600 Router Description on page 3
•
Overview of Installing the T1600 Router on page 175
Configuring DC Power on a T1600 Router
After you have connected the DC power and initially configured the router, you need to configure the number of input feeds if you connected fewer than six cables to the six-input
DC power supply.
For more information about configuring the DC power supply and the commands used in the procedures, see the Junos OS Administration Library .
•
Configuring DC Power on a T1600 Router (Five 60-A Cables on a Six-Input DC Power
272 Copyright © 2019, Juniper Networks, Inc.
Chapter 23: Configuring the JUNOS Software
Configuring DC Power on a T1600 Router (Five 60-A Cables on a Six-Input DC Power Supply)
When you connect five cables on a six-input DC power supply, you must specify the number of input feeds connected in the software. If the number of physical input feeds receiving power does not match the number of configured input feeds, the router displays an alarm message.
1.
Configure the number of input feeds to indicate that five DC power cables are connected.
[edit] user@host# set chassis pem feeds 5
NOTE: The default number of input feeds is 6.
2.
(Optional) Use the show statement to display the configuration to verify that it is correct.
[edit] user@host# show pem { feeds 5;
}
3.
Commit the configuration to activate it on the router, and exit configuration mode.
[edit] user@host# commit user@host# exit user@host>
Related
Documentation
•
•
T1600 Power System Description on page 113
•
Connecting DC Power to the T1600 Router (Five 60-A Inputs to Six-Input DC Power
•
Troubleshooting the T1600 Power System on page 552
•
T1600 DC Power Requirements on page 148
Copyright © 2019, Juniper Networks, Inc.
273
T1600 Core Router Hardware Guide
274 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 24
Upgrading to a T1600 Router from a T640
Router
•
Overview of Upgrading a T640 Router to a T1600 Router on page 275
•
Hardware Required for Upgrading from a T640 Router to a T1600 Router on page 277
•
T640 to T1600 Upgrade Kit on page 277
•
Verifying the Hardware Versions Before an Upgrade to a T1600 Router on page 278
•
Tools Required to Upgrade a T640 Router to a T1600 Router on page 284
•
Upgrading to a Supported T1600 Rear Fan Tray on page 284
•
Upgrading to Supported T1600 Power Supplies on page 287
•
Upgrading to T1600 SIBs on page 291
•
Upgrading to a T1600 Craft Interface on page 302
•
Attaching the T1600 Agency Label on page 306
•
Registering Your T1600 Upgrade on page 306
Overview of Upgrading a T640 Router to a T1600 Router
NOTE: The T640 router can be upgraded to a standalone T1600 router while the router is powered on and operational.
NOTE: Do not install T1600-FPC4s until after all upgrade procedures are completed.
To upgrade the T640 router to a T1600 router:
1.
If you have not already done so, install JUNOS Release 8.5 or later in the T640 router.
2.
Verify that control boards supported for the T1600 router are installed. If needed, order supported control boards, and install them before upgrading the SIBs.
Copyright © 2019, Juniper Networks, Inc.
275
T1600 Core Router Hardware Guide
3.
Verify that a rear fan tray supported for the T1600 routers is installed. If needed, order a supported rear fan tray, and install it before upgrading the power supplies.
4.
Prepare the site. Provision additional power as needed.
5.
Verify that power supplies supported for the T1600 routers are installed. If needed, order supported power supplies. Replace the power supplies before upgrading the
SIBs.
6.
Upgrade the existing standard SIBs to T1600-SIBs.
NOTE: During the SIB upgrade:
• The router should not experience packet loss if the traffic is less than
50 percent per Packet Forwarding Engine in each FPC.
• The router might experience some packet loss if the traffic is more than
50 percent per Packet Forwarding Engine in each FPC, depending on the operational environment.
For more information, contact your customer support representative.
7.
Remove the upper fan tray. See
“Upgrading to a Supported T1600 Rear Fan Tray” on page 284 .
8.
Replace the craft interface.
“Upgrading to a T1600 Craft Interface” on page 302
.
9.
Reinstall the upper fan tray. See
“Upgrading to a Supported T1600 Rear Fan Tray” on page 284 .
10.
Verify the installation of components.
11.
Attach the T1600 agency label.
12.
Register your T1600 upgrade.
Related
Documentation
•
T640 to T1600 Upgrade Kit on page 277
•
Verifying the Hardware Versions Before an Upgrade to a T1600 Router on page 278
276 Copyright © 2019, Juniper Networks, Inc.
Chapter 24: Upgrading to a T1600 Router from a T640 Router
Hardware Required for Upgrading from a T640 Router to a T1600 Router
To upgrade a T640 router to a standaloneT1600 router, you install the following hardware components:
• Two redundant, load-sharing power supplies. See
“T1600 Power System Description” on page 113
for a list of power supplies supported for the T1600 router.
NOTE: You cannot mix different DC power supplies in the same router except during upgrade. DC power supplies and AC power supplies must not be mixed in the same router.
• Five T1600-SIBs.
• One T1600 craft interface panel.
• See
“T1600 Control Boards Description” on page 74
for a list of control boards supported for the T1600 router.
For a T1600 router in a router matrix, additional components and different SIBs are required. See the TX Matrix Plus Router Hardware Guide for more information.
Related
Documentation
•
T640 to T1600 Upgrade Kit on page 277
•
Overview of Upgrading a T640 Router to a T1600 Router on page 275
•
Verifying the Hardware Versions Before an Upgrade to a T1600 Router on page 278
T640 to T1600 Upgrade Kit
You can order the required components individually or order a T1600 upgrade kit that contains various components. You might need to supply additional DC power cables, depending on your power supply.
NOTE: These components must be installed before you can install a
T1600-FPC in the T1600 router.
Related
Documentation
•
Overview of Upgrading a T640 Router to a T1600 Router on page 275
•
Verifying the Hardware Versions Before an Upgrade to a T1600 Router on page 278
Copyright © 2019, Juniper Networks, Inc.
277
T1600 Core Router Hardware Guide
Verifying the Hardware Versions Before an Upgrade to a T1600 Router
Before upgrading from a T640 router to a T1600 router, verify if the control boards, rear fan tray, and power supplies are supported for a T1600 router.
1.
Verifying the Hardware Version of the Control Board on page 278
2.
Verifying the Hardware Version of the Rear Fan Tray on page 281
3.
Verifying the Hardware Version of the Power Supplies on page 283
Verifying the Hardware Version of the Control Board
The T1600 router supports the following control boards:
• T Series control board (T-CB) model number (CB-T)
NOTE: The control board shown as CB-T in the CLI output is the T640 standard control board (model number CB-L-T), which is not supported for T1600 routers, and is not the T-series control board (model number
CB-T).
• Line-card chassis control board (LCC-CB) model number (CB-LCC)
To verify that supported control boards are installed:
1.
Issue the show chassis hardware command on the T640 router.
In this example, the show chassis hardware output shows that two control boards shown as Control Board (CB-T) are installed. These control boards are the T640 standard control boards (model number CB-L-T), and not T Series control boards user@host> show chassis hardware
Hardware inventory:
Item Version Part number Serial number Description
Chassis 65409 T640
Midplane REV 03 710-005608 RA1395 T640 Backplane
FPM GBUS REV 09 710-002901 RA2649 T640 FPM Board
FPM Display REV 05 710-002897 RA2608 FPM Display
CIP REV 06 710-002895 HS0753 T-series CIP
PEM 0 Rev 01 740-002595 MF16629 Power Entry Module
SCG 0 REV 11 710-003423 HS4313 T640 Sonet Clock Gen.
SCG 1 REV 11 710-003423 HR9161 T640 Sonet Clock Gen.
Routing Engine 0 REV 03 740-008883 211123900199 RE-4.0
Routing Engine 1 REV 03 740-008883 211123900248 RE-4.0
CB 0 REV 02 710-007655 HS5909 Control Board (CB-T)
CB 1 REV 02 710-007655 HS5910 Control Board (CB-T)
FPC 1 REV 07 710-007527 HR0716 FPC Type 2
CPU REV 15 710-001726 HS6048 FPC CPU
PIC 0 REV 07 750-001900 AR3722 1x OC-48 SONET, SMSR
PIC 1 REV 05 750-001900 AD3644 1x OC-48 SONET, SMSR
PIC 3 REV 06 750-001900 HD7603 1x OC-48 SONET, SMSR
MMB 1 REV 03 710-005555 HT5273 MMB-288mbit
PPB 0 REV 04 710-003758 HR4249 PPB Type 2
278 Copyright © 2019, Juniper Networks, Inc.
Chapter 24: Upgrading to a T1600 Router from a T640 Router
PPB 1 REV 04 710-003758 HR4257 PPB Type 2
FPC 2 REV 01 710-010233 HM4189 E-FPC Type 1
CPU REV 01 710-010169 HS9936 FPC CPU-Enhanced
PIC 1 REV 03 750-005719 HL8326 1x OC-12 ATM-II IQ, MM
PIC 2 REV 01 750-003141 AD9051 1x G/E, 1000 BASE-SX
MMB 1 REV 01 710-008923 HR0848 MMB 3M 288-bit
FPC 3 REV 01 710-010154 HR0863 E-FPC Type 3
CPU REV 01 710-010169 HN3422 FPC CPU-Enhanced
PIC 3 REV 01 750-009553 HP3576 4x OC-48 SONET
SFP 0 REV 01 740-009030 P11H5N1 SFP-LR
SFP 1 REV 01 740-009029 35D464P00060 SFP-IR
SFP 3 REV 01 740-009030 P11H5LM SFP-LR
MMB 0 REV 01 710-010171 HR0821 MMB-288mbit
MMB 1 REV 01 710-010171 HR0818 MMB-288mbit
SPMB 0 REV 09 710-003229 HT4177 T-series Switch CPU
SPMB 1 REV 09 710-003229 HT4176 T-series Switch CPU
SIB 0 REV 07 710-005781 HR5939 SIB-L8-F16
B Board REV 06 710-005782 HR5944 SIB-L8-F16 (B)
SIB 1 REV 02 710-005781 HZ2146 SIB-L8-F16
B Board REV 03 710-005782 HY4160 SIB-L8-F16 (B)
SIB 2 REV 07 710-005781 HR5925 SIB-L8-F16
B Board REV 03 710-005782 HY4161 SIB-L8-F16 (B)
SIB 3 REV 07 710-005781 HR5918 SIB-L8-F16
B Board REV 06 710-005782 HR5972 SIB-L8-F16 (B)
SIB 4 REV 07 710-005781 HR5935 SIB-L8-F16
B Board REV 06 710-005782 HR5969 SIB-L8-F16 (B)
In this example, the show chassis hardware output shows that two control boards shown as T-series Control Board are installed. These control boards are supported for a standalone T1600 router.
user@host> show chassis hardware
Hardware inventory:
Item Version Part number Serial number Description
Chassis JN1090E5DAHA T1600
Midplane REV 02 710-017247 RC0094 T640 Backplane
FPM GBUS REV 09 710-002901 WE0156 T640 FPM Board
FPM Display REV 02 710-002897 HE7864 FPM Display
CIP REV 06 710-002895 WD8691 T-series CIP
PEM 0 Rev 06 740-017906 TE27790 Power Entry Module 3x80
PEM 1 Rev 06 740-017906 TE27779 Power Entry Module 3x80
SCG 0 REV 14 710-003423 WF1874 T640 Sonet Clock Gen.
SCG 1 REV 14 710-003423 WF1881 T640 Sonet Clock Gen.
Routing Engine 0 REV 06 740-014082 1000688671 RE-A-2000
Routing Engine 1 REV 06 740-014082 1000688739 RE-A-2000
CB 0 REV 15 710-002728 HR8130 T-series Control Board
CB 1 REV 15 710-002728 HR8130 T-series Control Board
FPC 0 REV 10 710-010845 JZ2728 FPC Type 4
CPU REV 04 710-011481 JT8139 FPC CPU-Enhanced
PIC 0 REV 05 750-017405 DF3515 4x 10GE (LAN/WAN) XFP
Xcvr 0 REV 01 740-014279 KB405P1 XFP-10G-LR
Xcvr 1 REV 01 740-014289 C701XU05U XFP-10G-SR
MMB 0 REV 01 710-016606 JW7943 ST-MMB
FPC 1 REV 03 710-013035 DF5574 FPC Type 3-ES
CPU
FPC 2 REV 04 710-013560 WF7206 E2-FPC Type 3
CPU REV 03 710-013563 WE9007 FPC CPU-Enhanced
PIC 0 REV 16 750-007141 NF5528 10x 1GE(LAN), 1000 BASE
Copyright © 2019, Juniper Networks, Inc.
279
T1600 Core Router Hardware Guide
Xcvr 0 REV 01 740-011782 P8P085F SFP-SX
PIC 1 REV 12 750-009567 WF3566 1x 10GE(LAN),XENPAK
Xcvr 0 REV 02 740-013170 T07C94489 XENPAK-LR
PIC 2 REV 11 750-009567 CW9479 1x 10GE(LAN),XENPAK
Xcvr 0 REV 02 740-013170 T06F90331 XENPAK-LR
PIC 3 REV 07 750-012793 WF5106 1x 10GE(LAN/WAN) IQ2
Xcvr 0 REV 01 740-014279 KB405Q8 XFP-10G-LR
MMB 0 REV 06 710-010171 WF6759 MMB-5M3-288mbit
MMB 1 REV 06 710-010171 WF6800 MMB-5M3-288mbit
FPC 3 REV 04 710-013553 JW1482 E2-FPC Type 1
CPU REV 02 710-013563 JY4119 FPC CPU-Enhanced
PIC 0 REV 10 750-012266 JX5515 4x 1GE(LAN), IQ2
Xcvr 0 REV 01 740-011613 PAM2Y9H SFP-SX
Xcvr 1 REV 01 740-011613 PAM2Y99 SFP-SX
Xcvr 2 REV 01 740-011613 AM07287E42 SFP-SX
Xcvr 3 REV 01 740-011613 PAJ4SQL SFP-SX
PIC 1 REV 04 750-011209 HY3332 Adaptive Services-II
PIC 2 REV 03 750-011750 JH4537 Adaptive Services-II FIPS
MMB 1 REV 05 710-008923 JS8106 MMB 3M 288-bit
FPC 4 REV 04 710-013558 JX5622 E2-FPC Type 2
CPU REV 02 710-013563 JT5841 FPC CPU-Enhanced
PIC 3 REV 21 750-001901 HZ6258 4x OC-12 SONET, SMIR
MMB 1 REV 05 710-010171 JY3756 MMB-5M3-288mbit
FPC 5 REV 10 710-010845 JZ2728 FPC Type 4
CPU REV 04 710-011481 JT8139 FPC CPU-Enhanced
PIC 0 REV 01 750-010850 JA0329 1x OC-768 SONET SR
MMB 0 REV 01 710-016606 JW7943 ST-MMB
FPC 6 REV 10 710-010845 JZ2729 FPC Type 4
CPU REV 04 710-011481 JT8138 FPC CPU-Enhanced
PIC 0 REV 01 750-010850 JA0324 1x OC-768 SONET SR
MMB 0 REV 01 710-016606 JW7942 ST-MMB
FPC 7 REV 05 710-013558 WF4779 E2-FPC Type 2
CPU REV 03 710-013563 WF4663 FPC CPU-Enhanced
PIC 0 REV 09 750-011800 KA2397 8x 1GE(LAN), IQ2
Xcvr 0 REV 01 740-007326 P5S0PD9 SFP-SX
Xcvr 1 REV 01 740-007326 P5S0PD6 SFP-SX
Xcvr 2 REV 01 740-011613 PAJ4SQV SFP-SX
Xcvr 3 REV 01 740-011613 PAM2Y94 SFP-SX
Xcvr 5 REV 01 740-011613 P9R0AJV SFP-SX
Xcvr 7 REV 01 740-013111 70191002 SFP-T
MMB 1 REV 06 710-010171 WF4050 MMB-5M3-288mbit
SPMB 0 REV 10 710-003229 JZ1095 T-series Switch CPU
SPMB 1 REV 09 710-003229 HR8670 T-series Switch CPU
SIB 0 REV 01 710-005157 HJ9026 SIB-I8-F16
SIB 1 REV 01 710-005157 HJ4791 SIB-I8-F16
SIB 2 REV 01 710-005157 HJ4774 SIB-I8-F16
SIB 3 REV 01 710-005157 HJ4792 SIB-I8-F16
SIB 4 REV 01 710-005157 HJ4793 SIB-I8-F16
2.
Issue the show chassis hardware models command on the T640 router.
In this example, the show chassis hardware models output shows that two control boards shown as CB-L-T-S are installed. These control boards are the T640 standard control boards (model number CB-L-T), and not supported for the T1600 router.
user@host> show chassis hardware models
Hardware inventory:
280 Copyright © 2019, Juniper Networks, Inc.
Chapter 24: Upgrading to a T1600 Router from a T640 Router
Item Version Part number CLEI code FRU model number
Midplane REV 04 710-002726 CHAS-BP-T640-S
FPM Display REV 02 710-002897 CRAFT-T640-S
CIP REV 05 710-002895 CIP-L-T640-S
PEM 0 Rev 01 740-002595 PWR-T-DC-S
SCG 0 REV 04 710-003423 SCG-T-S
SCG 1 REV 04 710-003423 SCG-T-S
Routing Engine 0 REV 01 740-005022 RE-600-2048-S
Routing Engine 1 REV 07 740-005022 RE-600-2048-S
CB 0 REV 06 710-002726 CB-L-T-S
CB 1 REV 06 710-002728 CB-L-T-S
FPC 5 REV 05 710-007527 T640-FPC2
PIC 0 REV 05 750-002510 PB-2GE-SX
PIC 1 REV 05 750-001901 PB-4OC12-SON-SMIR
FPC 6 REV 03 710-001721 T640-FPC3
PIC 1 REV 01 750-009553 PC-4OC48-SON-SFP
SIB 4 REV 02 750-005486 SIB-I-T640-S
Fan Tray 0 FANTRAY-T-S
Fan Tray 1 FANTRAY-T-S
Fan Tray 2 FAN-REAR-TX-T640-S
3.
If model number CB-L-T is installed, order control boards supported by the T1600 router, and install them on your T640 router before upgrading to a T1600 router.
Verifying the Hardware Version of the Rear Fan Tray
The T1600 router supports the following rear fan trays:
• Model number FAN-REAR-TX-T640
• Model number FAN-REAR-TXP-LCC
NOTE: This fan tray is required for T1600 routers in a routing matrix.
• Model number FAN-R
The supported rear fan trays have eight fans, which are required to support the additional thermal power generation of the T1600 router. Model number RHTREARTRAY-T has five blowers and does not provide sufficient cooling for the T1600 router.
To verify that a supported rear fan tray is installed:
1.
Issue the show chassis hardware models command on the T640 router.
In this example, the show chassis hardware models output shows that the rear fan tray shown as FRU model numberFAN-REAR-TX-T640-S is installed. This rear fan tray is supported for the T1600 router.
user@host> show chassis hardware models
Hardware inventory:
Item Version Part number CLEI code FRU model number
Midplane REV 04 710-002726 CHAS-BP-T640-S
FPM Display REV 02 710-002897 CRAFT-T640-S
Copyright © 2019, Juniper Networks, Inc.
281
T1600 Core Router Hardware Guide
282
CIP REV 05 710-002895 CIP-L-T640-S
PEM 0 Rev 01 740-002595 PWR-T-DC-S
PEM 1 Rev 01 740-002595 PWR-T-DC-S
SCG 0 REV 04 710-003423 SCG-T-S
SCG 1 REV 04 710-003423 SCG-T-S
Routing Engine 0 REV 01 740-005022 RE-600-2048-S
Routing Engine 1 REV 07 740-005022 RE-600-2048-S
CB 0 REV 06 710-002726 CB-L-T-S
CB 1 REV 06 710-002728 CB-L-T-S
FPC 5 REV 05 710-007527 T640-FPC2
PIC 0 REV 05 750-002510 PB-2GE-SX
PIC 1 REV 05 750-001901 PB-4OC12-SON-SMIR
FPC 6 REV 03 710-001721 T640-FPC3
PIC 1 REV 01 750-009553 PC-4OC48-SON-SFP
SIB 4 REV 02 750-005486 SIB-I-T640-S
Fan Tray 0 FANTRAY-T-S
Fan Tray 1 FANTRAY-T-S
Fan Tray 2 FAN-REAR-TX-T640-S
2.
Issue the show chassis environment command:
In this example, the output shows that the rear fan tray has five blowers, indicating that the model number RHTREARTRAY-T rear fan tray is installed. The last five lines of the output for the fans each include Blower in the description.
user@host> show chassis environment
Fans Top Left Front fan OK Spinning at normal speed
Top Left Middle fan OK Spinning at normal speed
Top Left Rear fan OK Spinning at normal speed
Top Right Front fan OK Spinning at normal speed
Top Right Middle fan OK Spinning at normal speed
Top Right Rear fan OK Spinning at normal speed
Bottom Left Front fan OK Spinning at normal speed
Bottom Left Middle fan OK Spinning at normal speed
Bottom Left Rear fan OK Spinning at normal speed
Bottom Right Front fan OK Spinning at normal speed
Bottom Right Middle fan OK Spinning at normal speed
Bottom Right Rear fan OK Spinning at normal speed
Fourth Blower from top OK Spinning at normal speed
Bottom Blower OK Spinning at normal speed
Middle Blower OK Spinning at normal speed
Top Blower OK Spinning at normal speed
Second Blower from top OK Spinning at normal speed
In this example, the output shows that the rear fan tray has eight fans, indicating that the model number FAN-REAR-TX-T640-S rear fan tray is installed. The last eight lines of the output for the fans each begin with Rear Tray and include fan in the description.
user@host> show chassis environment
Fans Top Left Front fan OK Spinning at normal speed
Top Left Middle fan OK Spinning at normal speed
Top Left Rear fan OK Spinning at normal speed
Top Right Front fan OK Spinning at normal speed
Top Right Middle fan OK Spinning at normal speed
Top Right Rear fan OK Spinning at normal speed
Copyright © 2019, Juniper Networks, Inc.
Chapter 24: Upgrading to a T1600 Router from a T640 Router
Bottom Left Front fan OK Spinning at normal speed
Bottom Left Middle fan OK Spinning at normal speed
Bottom Left Rear fan OK Spinning at normal speed
Bottom Right Front fan OK Spinning at normal speed
Bottom Right Middle fan OK Spinning at normal speed
Bottom Right Rear fan OK Spinning at normal speed
Rear Tray Top fan OK Spinning at normal speed
Rear Tray Second fan OK Spinning at normal speed
Rear Tray Third fan OK Spinning at normal speed
Rear Tray Fourth fan OK Spinning at normal speed
Rear Tray Fifth fan OK Spinning at normal speed
Rear Tray Sixth fan OK Spinning at normal speed
Rear Tray Seventh fan OK Spinning at normal speed
Rear Tray Bottom fan OK Spinning at normal speed
3.
If model number RHTREARTRAY-T with five blowers is installed, order a supported rear fan tray, and install it before installing the power supplies supported for the T1600 router.
Verifying the Hardware Version of the Power Supplies
The T1600 router supports the following power supplies
• Three-input 240-A DC power supply (model number PWR-T1600-3-80-DC)
• Four-input 240-A DC power supply (model number PWR-T1600-4-60-DC)
• Six-input DC power supply (model number PWR-T-6-60-DC)
• Three-phase delta AC power supply (model number (PWR-T-10KW-DELTA-AC )
• Three-phase wye AC power supply (model number PWR-T-10KW-WYE-AC)
The T1600 router does not support the two-input 180-A DC power supply (model number
PWR-T-DC).
To verify that supported power supplies are installed:
1.
Issue the show chassis hardware models command on the T640 router.
In this example, the show chassis hardware models output shows that two power supplies shown as FRU model number PWR-T-DC-S are installed. These power supplies are the 2-input 160-A DC power supplies (model number PWR-T-DC), and not supported for the T1600 router.
user@host> show chassis hardware models
Hardware inventory:
Item Version Part number CLEI code FRU model number
Midplane REV 04 710-002726 CHAS-BP-T640-S
FPM Display REV 02 710-002897 CRAFT-T640-S
CIP REV 05 710-002895 CIP-L-T640-S
PEM 0 Rev 01 740-002595 PWR-T-DC-S
PEM 1 Rev 01 740-002595 PWR-T-DC-S
SCG 0 REV 04 710-003423 SCG-T-S
SCG 1 REV 04 710-003423 SCG-T-S
Copyright © 2019, Juniper Networks, Inc.
283
T1600 Core Router Hardware Guide
Routing Engine 0 REV 01 740-005022 RE-600-2048-S
Routing Engine 1 REV 07 740-005022 RE-600-2048-S
CB 0 REV 06 710-002726 CB-L-T-S
CB 1 REV 06 710-002728 CB-L-T-S
FPC 5 REV 05 710-007527 T640-FPC2
PIC 0 REV 05 750-002510 PB-2GE-SX
PIC 1 REV 05 750-001901 PB-4OC12-SON-SMIR
FPC 6 REV 03 710-001721 T640-FPC3
PIC 1 REV 01 750-009553 PC-4OC48-SON-SFP
SIB 0 REV 02 750-005486 SIB-I-T640-S
SIB 1 REV 02 750-005486 SIB-I-T640-S
SIB 2 REV 02 750-005486 SIB-I-T640-S
SIB 3 REV 02 750-005486 SIB-I-T640-S
SIB 4 REV 02 750-005486 SIB-I-T640-S
Fan Tray 0 FANTRAY-T-S
Fan Tray 1 FANTRAY-T-S
Fan Tray 2 FAN-REAR-TX-T640-S
2.
If two-input 160-A DC power supplies (model number PWR-T-DC) are installed in your T640 router, order power supplies supported by the T1600 router, and install them on your T640 router before upgrading to a T1600 router.
Related
Documentation
•
T1600 Hardware Component Overview on page 17
Tools Required to Upgrade a T640 Router to a T1600 Router
To upgrade the SIBs, you need the following tools and parts.
• Electrostatic discharge (ESD) grounding wrist strap
• Phillips (+) screwdrivers, numbers 1 and 2
Related
Documentation
•
Overview of Upgrading a T640 Router to a T1600 Router on page 275
•
Upgrading to T1600 SIBs on page 291
Upgrading to a Supported T1600 Rear Fan Tray
1.
Removing the RHTREARTRAY-T Rear Fan Tray on page 285
2.
Installing a Rear Fan Tray on page 286
284 Copyright © 2019, Juniper Networks, Inc.
Chapter 24: Upgrading to a T1600 Router from a T640 Router
Removing the RHTREARTRAY-T Rear Fan Tray
The rear fan tray is mounted vertically on the right side of the rear of the chassis. The rear fan tray (model number RHTREARTRAY-T) weighs about 12 lb (5.4 kg).
CAUTION: To maintain proper cooling, do not operate the router with the rear fan tray removed for more than 1 minute.
To remove the rear fan tray (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Loosen the captive screws on the top and bottom of the fan tray faceplate, using a
Phillips (+) screwdriver, number 2.
3.
Grasp the handles and pull the fan tray halfway out of the chassis.
WARNING: To avoid injury, keep tools and your fingers away from the fans as you slide the fan tray out of the chassis. The fans might still be spinning.
4.
When the fans stop spinning, grasp the handles and pull the fan tray completely out of the chassis.
Copyright © 2019, Juniper Networks, Inc.
285
T1600 Core Router Hardware Guide
Figure 119: Removing the Rear RHTREARTRAY-T Fan Tray
Installing a Rear Fan Tray
The rear fan tray (model number FAN-REAR-TX-T640-S) weighs about 10 pounds (4.5
kg). To install a replacement rear fan tray (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the fan tray by its handles and insert it straight into the chassis.
3.
Tighten the captive screws on the fan tray faceplate to secure it in the chassis, using a Phillips (+) screwdriver, number 2.
286 Copyright © 2019, Juniper Networks, Inc.
Figure 120: Installing a Rear Fan Tray
Chapter 24: Upgrading to a T1600 Router from a T640 Router
Related
Documentation
•
Hardware Required for Upgrading from a T640 Router to a T1600 Router on page 277
•
T640 to T1600 Upgrade Kit on page 277
•
Overview of Upgrading a T640 Router to a T1600 Router on page 275
•
Tools Required to Upgrade a T640 Router to a T1600 Router on page 284
•
Verifying the Hardware Versions Before an Upgrade to a T1600 Router on page 278
Upgrading to Supported T1600 Power Supplies
•
Removing a Two-Input 160-A DC Power Supply on page 288
•
Installing a T1600 Power Supply on page 290
Copyright © 2019, Juniper Networks, Inc.
287
T1600 Core Router Hardware Guide
Removing a Two-Input 160-A DC Power Supply
The power supplies are located at the rear of the chassis below the SIBs. Each two-input
160-A power supply weighs approximately 23 lb (10.5 kg).
CAUTION: Do not leave a power supply slot empty for more than 30 minutes while the router is operational. For proper airflow, the power supply must remain in the chassis, or a blank panel must be used in an empty slot.
To remove a power supply:
1.
Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during the removal process.
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
2.
For a nonredundant power supply, power off the system. See the T640 Core Router
Hardware Guide . For redundant power supplies, check that the other power supply is functional.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
Switch the circuit breakers on the power supply faceplate to the off position ( O ).
NOTE: After powering off a power supply, you must wait at least 60 seconds before turning it back on.
5.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
6.
Remove the nuts and washers from the terminal studs (see
Use a 7/16-in. (11 mm) nut driver.
288 Copyright © 2019, Juniper Networks, Inc.
Chapter 24: Upgrading to a T1600 Router from a T640 Router
Figure 121: Disconnecting Power Cables from a Two-Input 160-A DC Power Supply
7.
Remove the cable lugs from the terminal studs.
8.
Loosen the captive screws on the cable restraints on the right edge of the power supply faceplate.
9.
Carefully move the power cables out of the way.
10.
Loosen the captive screws on the lower corners of the power supply faceplate completely. Twist the ejector handles on the upper corners of the faceplate counterclockwise to unseat the power supply.
11.
Twist the ejector handles on the upper corners of the faceplate counterclockwise to unseat the power supply.
12.
Grasp the handle on the power supply faceplate, and pull firmly to start removing the power supply. Slide it halfway out of the chassis (see
WARNING: Do not touch the power connectors on the rear of the power supply (see
). They can contain dangerous voltages.
13.
Place one hand underneath the power supply to support it and slide it completely out of the chassis.
Copyright © 2019, Juniper Networks, Inc.
289
T1600 Core Router Hardware Guide
CAUTION: Each two-input 160-A power supply weighs approximately
23 lb (10.5 kg). Be prepared to support the full weight of the power supply as you remove it from the router.
Figure 122: Removing a Power Supply
Figure 123: Rear of the Power Supply Showing Midplane Connectors
Installing a T1600 Power Supply
For a list of power supplies supported by the T1600 router, see
. For the procedure to install a power supply, see
T1600 Routing Engine” on page 374 .
To install DC power supplies:
1.
Install one power supply.
290 Copyright © 2019, Juniper Networks, Inc.
Chapter 24: Upgrading to a T1600 Router from a T640 Router
2.
Connect power to the DC power supply.
For procedures to connect power, see the following topics:
•
•
Connecting DC Power to the T1600 Router (Six 60-A Inputs to Six-Input DC Power
•
Connecting DC Power to the T1600 Router (Five 60-A Inputs to Six-Input DC Power
3.
Repeat the procedure for the other DC power supply.
NOTE: Before installing AC power supplies, the router must be powered down, and both DC power supplies must be removed. Mixing DC power supplies and AC power supplies in the same router is not supported.
When upgrading to AC power supplies:
1.
Install the power supplies.
2.
Connect power to the power supplies.
•
Connecting AC Power to a T1600 Router with Three-Phase Delta AC Power Supplies on page 259
•
Connecting AC Power to a T1600 Router with Three-Phase Wye AC Power Supplies on page 262
3.
Power on the router. See
“Powering On the AC-Powered T1600 Router” on page 264 .
Related
Documentation
•
Hardware Required for Upgrading from a T640 Router to a T1600 Router on page 277
•
T640 to T1600 Upgrade Kit on page 277
•
Overview of Upgrading a T640 Router to a T1600 Router on page 275
•
Tools Required to Upgrade a T640 Router to a T1600 Router on page 284
•
Verifying the Hardware Versions Before an Upgrade to a T1600 Router on page 278
Upgrading to T1600 SIBs
To convert an operational T640 router to a T1600 router, you upgrade the standard SIBs or SIBs version B in the T640 router to T1600-SIBs or LCC-SIBs. You repeat the upgrade procedures for each of the five SIBs in the router.
Copyright © 2019, Juniper Networks, Inc.
291
T1600 Core Router Hardware Guide
NOTE: During the SIB upgrade:
• The router should not experience packet loss if the traffic is less than
50 percent per Packet Forwarding Engine in each FPC.
• The router might experience some packet loss if the traffic is more than
50 percent per Packet Forwarding Engine in each FPC, depending on the operational environment.
For more information, contact your customer support representative.
1.
Preparing to Upgrade the SIBs on page 292
2.
Removing a Standard SIB or SIB Version B on page 293
3.
Installing a T1600-SIB on page 295
4.
Verifying the Installation of a T1600-SIB on page 296
5.
Exiting Upgrade Mode on page 297
6.
Verifying Operation on page 298
Preparing to Upgrade the SIBs
To prepare to upgrade the SIBs:
1.
The T640 router must contain five standard SIBs or SIBs version B before the upgrade.
Verify that four SIBs are in the Online state and one SIB is in the Spare state. Display the status of the SIBs by issuing the show chassis sibs command: user@host> show chassis sibs
Slot State Uptime
0 Spare 255 days, 30 minutes, 12 seconds
1 Online 255 days, 25 minutes, 45 seconds
2 Online 255 days, 20 minutes, 28 seconds
3 Online 255 days, 15 minutes, 7 seconds
4 Online 255 days, 10 minutes, 52 seconds
To bring a SIB online, issue the request chassis sib online operational mode command.
To install additional SIBs, use the standard installation procedure described in the
T640 Core Router Hardware Guide .
NOTE: Do not proceed with the upgrade until all five SIBs are present and operational.
2.
Enter configuration mode.
user@host> configure
3.
Include the fabric upgrade-mode statement in the configuration at the [edit chassis] hierarchy level.
292 Copyright © 2019, Juniper Networks, Inc.
Chapter 24: Upgrading to a T1600 Router from a T640 Router user@host# set chassis fabric upgrade-mode
4.
Commit the configuration:
• If GRES is enabled, commit the configuration on both the master and the backup
Routing Engines: user@host# commit synchronize
• If GRES is not enabled, commit the configuration on the master Routing Engine: user@host# commit
5.
Exit configuration mode.
user@host# exit
Removing a Standard SIB or SIB Version B
NOTE: Replace the spare SIB first, and verify the operation of the replacement before replacing the other SIBs.
To remove a standard SIB or SIB version B:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis.
2.
Take the SIB offline by using one of the following methods:
• Press and hold the ONLINE/OFFLINE button on the SIB faceplate for about five seconds until the OK LED is not lit.
• Issue the request chassis sib offline command. For example: user@host> request chassis sib offline slot 0
NOTE: When you bring an active SIB offline, the spare SIB becomes active and transitions to the Online state.
3.
Loosen the captive screws (using a Phillips (+) screwdriver, number 2) on the ejector handles on each side of the SIB faceplate.
4.
Flip the ejector handles outward to unseat the SIB.
Copyright © 2019, Juniper Networks, Inc.
293
T1600 Core Router Hardware Guide
5.
Grasp both ejector handles, pull firmly, and slide the SIB about three-quarters of the way out of the chassis.
6.
Place one hand underneath the SIB to support it and slide it completely out of the chassis. Place the SIB on the antistatic mat.
CAUTION: Do not stack hardware components on one another after you remove them. Place each component on an antistatic mat resting on a stable, flat surface.
Figure 124: Removing a SIB from a T640 Router
Figure 125: Standard SIB Supported in a T640 Router
294 Copyright © 2019, Juniper Networks, Inc.
Chapter 24: Upgrading to a T1600 Router from a T640 Router
Installing a T1600-SIB
Each T1600-SIB weighs approximately 6.5 lb (3 kg). To install a T1600-SIB (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis.
2.
Place one hand underneath the T1600-SIB to support it. With the other hand, hold one of the ejector handles on the T1600-SIB faceplate.
3.
Carefully align the sides of the T1600-SIB with the guides inside the chassis.
4.
Slide the T1600-SIB into the chassis, carefully ensuring that it is correctly aligned.
5.
Grasp both ejector handles and press them inward to seat the T1600-SIB. Ensure that the ejector handle tabs are properly mated inside their corresponding chassis slots.
You might have to close and open the handles a few times before the tabs catch the slots.
6.
Tighten the captive screws on the ejector handles.
7.
Bring the T1600-SIB online using one of the following methods:
• Press and hold the ONLINE/OFFLINE button on the T1600-SIB faceplate. The green
OK LED on the faceplate begins to blink. Hold the button down until the LED blinks.
• Issue the following CLI command on the router: user@host> request chassis sib online slot 0
Copyright © 2019, Juniper Networks, Inc.
295
T1600 Core Router Hardware Guide
Figure 126: Installing a T1600-SIB
Verifying the Installation of a T1600-SIB
To verify that the T1600-SIB is functioning normally:
1.
Check the LEDs on the T1600-SIB faceplate.
• The green OK LED should light steadily a few minutes after the T1600-SIB is installed.
• If the FAIL LED is lit steadily, remove and install the T1600-SIB again. Make sure that the T1600-SIB is seated properly. If the FAIL LED still lights steadily, the
T1600-SIB is not functioning properly. Contact your customer support representative.
2.
Verify that four T1600-SIB are in the Online state and one SIB is in the Spare state.
Display the status of the T1600-SIB by issuing the show chassis sibs command: user@host> show chassis sibs
Slot State Uptime
0 Spare 0 days, 30 minutes, 12 seconds
1 Online 0 days, 25 minutes, 45 seconds
2 Online 0 days, 20 minutes, 28 seconds
3 Online 0 days, 15 minutes, 7 seconds
4 Online 0 days, 10 minutes, 52 seconds
To bring a T1600-SIB online, issue the request chassis sib online operational mode command.
296 Copyright © 2019, Juniper Networks, Inc.
Chapter 24: Upgrading to a T1600 Router from a T640 Router
Exiting Upgrade Mode
After all five T1600-SIBs have been installed, exit upgrade mode:
1.
Determine if graceful Routing Engine switchover (GRES) is enabled.
user@host> show system switchover
Graceful switchover: On
Configuration database: Ready
Kernel database: Ready
2.
Verify that the Routing Engines are operating properly by issuing the show chassis routing-engine command.
user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
Temperature 32 degrees C / 89 degrees F
CPU temperature 33 degrees C / 91 degrees F
DRAM 2048 MB
Memory utilization 8 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 2 percent
Interrupt 0 percent
Idle 98 percent
Model RE-4.0
Serial ID P13004101110
Start time 2007-04-30 08:38:22 PDT
Uptime 2 days, 2 hours, 22 minutes, 43 seconds
Load averages: 1 minute 5 minute 15 minute
0.02 0.02 0.00
3.
Enter configuration mode.
user@host> configure
4.
Delete the fabric upgrade-mode statement in the configuration at the [edit chassis] hierarchy level.
user@host# delete chassis fabric upgrade-mode
5.
Commit the configuration:
• If GRES is enabled, commit the configuration on both the master and the backup
Routing Engines: user@host# commit synchronize
• If GRES is not enabled, commit the configuration on the master Routing Engine:
Copyright © 2019, Juniper Networks, Inc.
297
T1600 Core Router Hardware Guide user@host# commit
6.
Exit configuration mode.
user@host# exit
Verifying Operation
Use the following commands to verify proper operation of the T1600 router:
1.
Verify that the model number is now T1600 by issuing the show version command.
user@host> show version
Hostname: myhost
Model: t1600
JUNOS Base OS boot [8.5R1]
JUNOS Base OS Software Suite [8.5R1]
JUNOS Kernel Software Suite [8.5R1]
JUNOS Crypto Software Suite [8.5R1]
JUNOS Packet Forwarding Engine Support (M/T Common) [8.5R1] JUNOS Packet Forwarding Engine Support
(T-Series) [8.5R1] JUNOS Online Documentation [8.5R1] JUNOS Routing Software Suite [8.5R1]
2.
Verify that no alarms are present by issuing the show chassis alarms command.
user@host> show chassis alarms
No alarms currently active
3.
Verify that the LEDs and indicators on the craft interface show that the router is operating properly by issuing the show chassis craft-interface command.
user@host> show chassis craft-interface
FPM Display contents:
+--------------------+
|Myhost router |
|Up: 0+22:34 |
| |
|Temperature OK |
+--------------------|
Front Panel System LEDs:
Routing Engine 0 1
--------------------------
OK * *
Fail . .
Master * .
Front Panel Alarm Indicators:
-----------------------------
Red LED .
Yellow LED .
Major relay .
Minor relay .
Front Panel FPC LEDs:
FPC 0 1 2 3 4 5 6 7
298 Copyright © 2019, Juniper Networks, Inc.
Chapter 24: Upgrading to a T1600 Router from a T640 Router
------------------------------------
Red . . . . . . . .
Green * * * * * * * *
CB LEDs:
CB 0 1
--------------
Amber . .
Green * *
Blue * .
SCG LEDs:
SCG 0 1
--------------
Amber . .
Green * *
Blue * .
SIB LEDs:
SIB 0 1 2 3 4
--------------------------
Red . . . . .
Green * * * * *
4.
Verify that all FPCs in the router are detected and online by issuing the show chassis fpc and show chassis hardware commands.
user@host> show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online 41 6 0 1024 6 49
1 Online 35 4 0 1024 4 49
2 Online 35 4 0 1024 4 49
3 Online 31 1 0 1024 2 49
4 Online 33 1 0 1024 2 49
5 Online 56 9 0 2048 5 24
6 Online 35 4 0 1024 4 49
7 Online 32 1 0 1024 2 49 user@host> show chassis hardware
Hardware inventory:
Item Version Part number Serial number Description
Chassis JN1090E5DAHA T1600
Midplane REV 02 710-017247 RC0094 T640 Backplane
FPM GBUS REV 09 710-002901 WE0156 T640 FPM Board
FPM Display REV 05 710-021387 DE4543 T1600 FPM Display
CIP REV 06 710-002895 WD8691 T-series CIP
PEM 0 Rev 06 740-017906 TE27790 Power Entry Module 3x80
PEM 1 Rev 06 740-017906 TE27779 Power Entry Module 3x80
SCG 0 REV 14 710-003423 WF1874 T640 Sonet Clock Gen.
SCG 1 REV 14 710-003423 WF1881 T640 Sonet Clock Gen.
Routing Engine 0 REV 06 740-014082 1000688671 RE-A-2000
Routing Engine 1 REV 06 740-014082 1000688739 RE-A-2000
CB 0 REV 15 710-002728 HR8130 T-series Control Board
CB 1 REV 15 710-002728 HR8130 T-series Control Board
FPC 0 REV 10 710-010845 JZ2728 FPC Type 4
CPU REV 04 710-011481 JT8139 FPC CPU-Enhanced
Copyright © 2019, Juniper Networks, Inc.
299
T1600 Core Router Hardware Guide
PIC 0 REV 05 750-017405 DF3515 4x 10GE (LAN/WAN) XFP
Xcvr 0 REV 01 740-014279 KB405P1 XFP-10G-LR
Xcvr 1 REV 01 740-014289 C701XU05U XFP-10G-SR
MMB 0 REV 01 710-016606 JW7943 ST-MMB
FPC 1 REV 03 710-013035 DF5574 FPC Type 3-ES
CPU
FPC 2 REV 04 710-013560 WF7206 E2-FPC Type 3
CPU REV 03 710-013563 WE9007 FPC CPU-Enhanced
PIC 0 REV 16 750-007141 NF5528 10x 1GE(LAN), 1000 BASE
Xcvr 0 REV 01 740-011782 P8P085F SFP-SX
PIC 1 REV 12 750-009567 WF3566 1x 10GE(LAN),XENPAK
Xcvr 0 REV 02 740-013170 T07C94489 XENPAK-LR
PIC 2 REV 11 750-009567 CW9479 1x 10GE(LAN),XENPAK
Xcvr 0 REV 02 740-013170 T06F90331 XENPAK-LR
PIC 3 REV 07 750-012793 WF5106 1x 10GE(LAN/WAN) IQ2
Xcvr 0 REV 01 740-014279 KB405Q8 XFP-10G-LR
MMB 0 REV 06 710-010171 WF6759 MMB-5M3-288mbit
MMB 1 REV 06 710-010171 WF6800 MMB-5M3-288mbit
FPC 3 REV 04 710-013553 JW1482 E2-FPC Type 1
CPU REV 02 710-013563 JY4119 FPC CPU-Enhanced
PIC 0 REV 10 750-012266 JX5515 4x 1GE(LAN), IQ2
Xcvr 0 REV 01 740-011613 PAM2Y9H SFP-SX
Xcvr 1 REV 01 740-011613 PAM2Y99 SFP-SX
Xcvr 2 REV 01 740-011613 AM07287E42 SFP-SX
Xcvr 3 REV 01 740-011613 PAJ4SQL SFP-SX
PIC 1 REV 04 750-011209 HY3332 Adaptive Services-II
PIC 2 REV 03 750-011750 JH4537 Adaptive Services-II FIPS
MMB 1 REV 05 710-008923 JS8106 MMB 3M 288-bit
FPC 4 REV 04 710-013558 JX5622 E2-FPC Type 2
CPU REV 02 710-013563 JT5841 FPC CPU-Enhanced
PIC 3 REV 21 750-001901 HZ6258 4x OC-12 SONET, SMIR
MMB 1 REV 05 710-010171 JY3756 MMB-5M3-288mbit
FPC 5 REV 10 710-010845 JZ2728 FPC Type 4
CPU REV 04 710-011481 JT8139 FPC CPU-Enhanced
PIC 0 REV 01 750-010850 JA0329 1x OC-768 SONET SR
MMB 0 REV 01 710-016606 JW7943 ST-MMB
FPC 6 REV 10 710-010845 JZ2729 FPC Type 4
CPU REV 04 710-011481 JT8138 FPC CPU-Enhanced
PIC 0 REV 01 750-010850 JA0324 1x OC-768 SONET SR
MMB 0 REV 01 710-016606 JW7942 ST-MMB
FPC 7 REV 05 710-013558 WF4779 E2-FPC Type 2
CPU REV 03 710-013563 WF4663 FPC CPU-Enhanced
PIC 0 REV 09 750-011800 KA2397 8x 1GE(LAN), IQ2
Xcvr 0 REV 01 740-007326 P5S0PD9 SFP-SX
Xcvr 1 REV 01 740-007326 P5S0PD6 SFP-SX
Xcvr 2 REV 01 740-011613 PAJ4SQV SFP-SX
Xcvr 3 REV 01 740-011613 PAM2Y94 SFP-SX
Xcvr 5 REV 01 740-011613 P9R0AJV SFP-SX
Xcvr 7 REV 01 740-013111 70191002 SFP-T
MMB 1 REV 06 710-010171 WF4050 MMB-5M3-288mbit
SPMB 0 REV 10 710-003229 JZ1095 T-series Switch CPU
SPMB 1 REV 09 710-003229 HR8670 T-series Switch CPU
SIB 0 REV 05 710-013074 DE7894 SIB-I8-SF
SIB 1 REV 05 710-013074 DE7916 SIB-I8-SF
SIB 2 REV 05 710-013074 DE7890 SIB-I8-SF
SIB 3 REV 05 710-013074 DE7883 SIB-I8-SF
SIB 4 REV 05 710-013074 DE7913 SIB-I8-SF
5.
Verify that all interfaces in the router are up by issuing the show interfaces terse command:
300 Copyright © 2019, Juniper Networks, Inc.
Chapter 24: Upgrading to a T1600 Router from a T640 Router user@host> show interfaces terse
Interface Admin Link Proto Local Remote xe-0/0/0 up up xe-0/0/1 up down xe-0/0/2 up down xe-0/0/3 up down ge-2/0/0 up down ge-2/0/1 up down ge-2/0/2 up down ge-2/0/3 up down ge-2/0/4 up down ge-2/0/5 up down ge-2/0/6 up down ge-2/0/7 up down ge-2/0/8 up down ge-2/0/9 up down ge-2/1/0 up up ge-2/2/0 up up pc-2/3/0 up up pc-2/3/0.16383 up up inet 10.0.0.1 --> 10.0.0.51
10.0.0.6 --> 0/0 xe-2/3/0 up down ge-3/0/0 up up pc-3/0/0 up up pc-3/0/0.16383 up up inet 10.0.0.1 --> 10.0.0.64
10.0.0.6 --> 0/0 ge-3/0/1 up up ge-3/0/2 up down ge-3/0/3 up up gr-3/1/0 up up ip-3/1/0 up up mt-3/1/0 up up pd-3/1/0 up up pe-3/1/0 up up sp-3/1/0 up up sp-3/1/0.16383 up up inet 10.0.0.1 --> 10.0.0.65
vt-3/1/0 up up gr-3/2/0 up up ip-3/2/0 up up mt-3/2/0 up up pd-3/2/0 up up pe-3/2/0 up up sp-3/2/0 up up sp-3/2/0.16383 up up inet 10.0.0.1 --> 10.0.0.66
vt-3/2/0 up up so-4/3/0 up up so-4/3/1 up down so-4/3/2 up down so-4/3/3 up down so-5/0/0 up up so-5/1/0 up up so-5/1/1 up up so-5/1/2 up down so-5/1/3 up down ge-7/0/0 up up pc-7/0/0 up up pc-7/0/0.16383 up up inet 10.0.0.1 --> 10.0.0.128
10.0.0.6 --> 0/0 ge-7/0/1 up up ge-7/0/2 up down
Copyright © 2019, Juniper Networks, Inc.
301
T1600 Core Router Hardware Guide ge-7/0/3 up up ge-7/0/4 up down ge-7/0/5 up down ge-7/0/6 up down ge-7/0/7 up up bcm0 up up bcm0.0 up up inet 10.0.0.4/8
inet6 fe80::200:ff:fe00:4/64
fec0::a:0:0:4/64
tnp 4 dsc up up em0 up up em0.0 up up inet 10.0.0.4/8
inet6 fe80::200:1ff:fe00:4/64
fec0::a:0:0:4/64
tnp 4 fxp0 up up fxp0.0 up up inet 192.168.168.34/22 gre up up ipip up up lo0 up up lo0.0 up up inet 10.255.168.34 --> 0/0
127.0.0.1 --> 0/0
iso 47.0005.80ff.f800.0000.0108.0001.0102.5516.8034
inet6 abcd::10:255:168:34
fe80::2a0:a5ff:fe5e:59f5 lo0.16384 up up inet 127.0.0.1 --> 0/0 lo0.16385 up up inet lsi up up mtun up up pimd up up pime up up tap up up
Related
Documentation
•
Hardware Required for Upgrading from a T640 Router to a T1600 Router on page 277
•
T640 to T1600 Upgrade Kit on page 277
•
Overview of Upgrading a T640 Router to a T1600 Router on page 275
•
Tools Required to Upgrade a T640 Router to a T1600 Router on page 284
•
Verifying the Hardware Versions Before an Upgrade to a T1600 Router on page 278
Upgrading to a T1600 Craft Interface
1.
Removing the T1600 Upper Front Fan Tray on page 302
2.
Removing the T640 Craft Interface on page 303
3.
Installing the T1600 Craft Interface on page 304
4.
Reinstalling the T1600 Upper Front Fan Tray on page 305
Removing the T1600 Upper Front Fan Tray
Before you remove the craft interface, remove the front upper fan tray.
302 Copyright © 2019, Juniper Networks, Inc.
Chapter 24: Upgrading to a T1600 Router from a T640 Router
NOTE: Remove the front upper fan tray to make the craft interface easier to replace and to avoid injury and damaging the equipment.
The upper front fan tray is located above the FPC card cage. The fan tray weighs about
18.6 lb (8.4 kg). To remove the upper front fan tray (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis.
2.
Loosen the captive screws on the corners of the fan tray faceplate.
3.
Grasp the handles and pull the fan tray halfway out of the chassis.
WARNING: To avoid injury, keep tools and your fingers away from the fans as you slide the fan tray out of the chassis. The fans might still be spinning.
4.
When the fans stop spinning, place one hand under the fan tray to support it and pull the fan tray completely out of the chassis.
Figure 127: Removing a Front Fan Tray
Removing the T640 Craft Interface
The craft interface is hot-insertable and hot-removable. When you install the craft interface, allow several minutes for the display to reflect the current state of the T1600 router.
Copyright © 2019, Juniper Networks, Inc.
303
T1600 Core Router Hardware Guide
The craft interface is located on the front of the chassis above the FPC card cage. The craft interface weighs approximately 2 lb (0.9 kg). To remove the craft interface (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis.
2.
Completely loosen the screws at the four corners of the craft interface.
3.
Insert the blade of a flat-blade screwdriver into the slot on one side of the craft interface, then gently pry that side out from the chassis.
4.
Repeat Step
for the other side of the craft interface.
5.
Grasp the craft interface by the top and bottom edges and carefully pull it straight out of the chassis.
Figure 128: Removing the T640 Craft Interface
Installing the T1600 Craft Interface
To install the T1600 craft interface (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis.
2.
Grasping the craft interface by the top and bottom edges, press it into place.
3.
Tighten the screws at the corners of the craft interface.
NOTE: When you install the craft interface in an operating T1600 router, allow several minutes for the LEDs on the craft interface to reflect the current state of the T1600 router.
304 Copyright © 2019, Juniper Networks, Inc.
Chapter 24: Upgrading to a T1600 Router from a T640 Router
After you install the replacement craft interface, immediately reinstall the upper front fan tray.
Figure 129: Installing a Replacement Craft Interface
Reinstalling the T1600 Upper Front Fan Tray
To install the upper front fan tray (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis.
2.
Grasp the fan tray by its handles and insert it straight into the chassis.
3.
Tighten the captive screws on each side of the fan tray faceplate to secure it in the chassis.
Figure 130: Installing a Front Fan Tray
Related
Documentation
•
Hardware Required for Upgrading from a T640 Router to a T1600 Router on page 277
•
T640 to T1600 Upgrade Kit on page 277
Copyright © 2019, Juniper Networks, Inc.
305
T1600 Core Router Hardware Guide
•
Overview of Upgrading a T640 Router to a T1600 Router on page 275
•
Tools Required to Upgrade a T640 Router to a T1600 Router on page 284
•
Verifying the Hardware Versions Before an Upgrade to a T1600 Router on page 278
Attaching the T1600 Agency Label
To attach the T1600 agency label:
1.
Locate the T640 agency label on the side of the chassis.
2.
Peel the protective backing off the T1600 agency label.
3.
Apply the T1600 agency label on top of the T640 agency label.
Related
Documentation
•
Overview of Upgrading a T640 Router to a T1600 Router on page 275
•
Registering Your T1600 Upgrade on page 306
Registering Your T1600 Upgrade
You must register the T1600 upgrade with Juniper Networks upon completion of the upgrade. To register your upgrade:
1.
Log on to the Juniper Networks Customer Support Center at https://www.juniper.net/customers/support/ .
2.
Click on Update Install Base .
3.
Follow the instructions provided in this link.
After your T1600 upgrade is registered, allow up to 45 days for restocking of the new hardware configuration to support any Next Day or Same Day contracts. Juniper Networks will provide Best Effort support until restocking of the upgraded product is complete.
306 Copyright © 2019, Juniper Networks, Inc.
PART 4
Installing and Replacing Components
•
Overview of Installing and Replacing Components on page 309
•
Replacing Chassis Components on page 313
•
Replacing Cooling System Components on page 337
•
Replacing Host Subsystem Components on page 365
•
Replacing Line Card Components on page 395
•
Replacing Power System Components on page 413
•
Replacing Switch Fabric Components on page 479
Copyright © 2019, Juniper Networks, Inc.
307
T1600 Core Router Hardware Guide
308 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 25
Overview of Installing and Replacing
Components
•
T1600 Field-Replaceable Units on page 309
•
Tools and Parts Required for Replacing T1600 Hardware Components on page 310
T1600 Field-Replaceable Units
Field-replaceable units (FRUs) are router components that can be replaced at the customer site. Replacing most FRUs requires minimal router downtime. The router uses the following types of FRUs:
• Hot-removable and hot-insertable FRUs—You can remove and replace these components without powering off the router or disrupting the routing functions.
• Hot-pluggable FRUs—You can remove and replace these components without powering down the router, but the routing functions of the system are interrupted when the component is removed.
NOTE: Before you replace most host subsystem components, such as a control board or Routing Engine, you must take the host subsystem offline.
However, it is not necessary to halt the host subsystem to insert or remove a PC card.
You must power off the Routing Engine before replacing a CompactFlash card or solid-state disk in a Routing Engine.
lists the FRUs for the router.
Copyright © 2019, Juniper Networks, Inc.
309
T1600 Core Router Hardware Guide
Table 106: Field-Replaceable Units
Hot-Removable and Hot-Insertable FRUs Hot-Pluggable FRUs
Air filters
Craft Interface
Flexible PIC Concentrators (FPCs)
Front and rear fan trays
PICs
Redundant power supplies
Master SONET Clock Generators (SCG)
Switch Interface Boards (T1600-SIBs or
TXP-T1600 SIBs)
Backup control board (T-CB or LCC-CB)
Master control board (T-CB or LCC-CB) (if nonstop active routing is configured)
Backup Routing Engine
Master Routing Engine (if nonstop active routing is configured)
Connector Interface Panel (CIP)
Nonredundant control boards (T-CB and
LCC-CB)
Master control board (T-CB or LCC-CB) (if nonstop active routing is not configured)
Nonredundant Routing Engine
Master Routing Engine (if nonstop active routing is not configured)
Master SONET Clock Generator (SCG)
Nonredundant SONET Clock Generator (SCG)
Related
Documentation
•
Taking the T1600 Host Subsystem Offline on page 365
•
System Architecture Description for T Series Routers on page 6
•
T1600 Chassis Description on page 21
Tools and Parts Required for Replacing T1600 Hardware Components
To replace hardware components, you need the tools and parts listed in
Table 107: Tools and Parts Required for Component Replacement
Components Tool or part
All
AC power supply
Three-phase delta AC power supply or three-phase wye AC power supply
Air filter (front or rear)
Electrostatic discharge (ESD) grounding wrist strap
Phillips (+) screwdrivers, number 2 to access the metal AC wiring compartment
1/4-in. slotted screwdriver to attach the ground wire and input terminal wires of the AC power cord.
Phillips (+) screwdrivers, numbers 1 and 2
310 Copyright © 2019, Juniper Networks, Inc.
Chapter 25: Overview of Installing and Replacing Components
Table 107: Tools and Parts Required for Component Replacement (continued)
Components Tool or part
CIP
Craft interface
Phillips (+) screwdrivers, numbers 1 and 2
Phillips (+) screwdrivers, numbers 1 and 2
DC power supply Phillips (+) screwdrivers, numbers 1 and 2
Three-input 240-A DC power supply, four-input
240-A DC power supply, or six-input DC power supply
7/16-in. (11 mm) nut driver
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts.
Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
Flashlight
Nonconductive sharp object
DC power supply cable 7/16-in. (11 mm) nut driver
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts.
Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
Phillips (+) screwdrivers, numbers 1 and 2 Fan tray (front or rear)
FPC Phillips (+) screwdrivers, numbers 1 and 2
Blank panel (if component is not reinstalled)
Electrostatic bag or antistatic mat
PIC Phillips (+) screwdrivers, numbers 1 and 2
Rubber safety cap for fiber-optic PICs or fiber-optic PIC cables
Flat-blade (–) screwdriver for Type 1 PICs
Electrostatic bag or antistatic mat
Blank panel (if component is not reinstalled)
Routing Engine Phillips (+) screwdrivers, numbers 1 and 2
Electrostatic bag or antistatic mat
Blank panel (if component is not reinstalled)
Serial cable to AUXILIARY or CONSOLE Routing
Engine port
Flat-blade (–) screwdriver
Copyright © 2019, Juniper Networks, Inc.
311
T1600 Core Router Hardware Guide
Table 107: Tools and Parts Required for Component Replacement (continued)
Components Tool or part
T1600-SIB
SCG
T-CB or LCC-CB
Phillips (+) screwdrivers, numbers 1 and 2
Electrostatic bag or antistatic mat
Blank panel (if component is not reinstalled)
Phillips (+) screwdrivers, numbers 1 and 2
Phillips (+) screwdrivers, numbers 1 and 2
Electrostatic bag or antistatic mat
Blank panel (if component is not reinstalled)
Related
Documentation
•
T1600 Chassis Description on page 21
•
T1600 Router Description on page 3
•
Returning a Hardware Component to Juniper Networks, Inc. on page 580
312 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 26
Replacing Chassis Components
•
Replacing the T1600 Front Air Filter on page 313
•
Replacing the T1600 Rear Air Filter on page 316
•
Replacing the T1600 Alarm Relay Wires on page 320
•
Replacing a T1600 Console or Auxiliary Cable on page 323
•
Replacing a T1600 Management Ethernet Cable on page 325
•
Replacing a T1600 CIP on page 328
•
Replacing the T1600 Craft Interface on page 331
•
Replacing a T1600 SCG on page 333
Replacing the T1600 Front Air Filter
1.
Removing the T1600 Front Air Filter on page 313
2.
Installing the T1600 Front Air Filter on page 315
Removing the T1600 Front Air Filter
The front air filter, located below the FPC card cage in the front of the chassis, and installs horizontally. The front air filter weighs approximately 1 lb (0.5 kg).The air filters are hot-insertable and hot-removable.
To remove the front air filter (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Unwrap any PIC cables from the spools on the cable management system, and remove the cables from the tray. Arrange the cables so that they do not block the front of the cable management system and tray, and secure them with temporary fasteners so that they are not supporting their own weight as they hang from the connector.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
Copyright © 2019, Juniper Networks, Inc.
313
T1600 Core Router Hardware Guide
3.
Simultaneously pull the two releases on the cable management system. Lift it up and outward to lock it in place to access the air filter.
4.
Loosen the captive screws on the corners of the air filter faceplate.
5.
Grasp the handles and pull the air filter straight out of the chassis.
6.
Remove the filter element from the air filter frame (see
Figure 131: Removing the Front Air Filter
314
Figure 132: Replacing the Front Filter Element
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 Cooling System Description on page 39
•
Troubleshooting the T1600 Cooling System on page 543
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
•
Maintaining the T1600 Air Filters on page 510
Copyright © 2019, Juniper Networks, Inc.
Chapter 26: Replacing Chassis Components
Installing the T1600 Front Air Filter
To install the front air filter (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Insert the filter element into the air filter frame.
3.
Grasp the air filter by the handles on its faceplate, and slide it straight into the chassis.
4.
Tighten the captive screws on the corners of the faceplate.
5.
Unlock the cable management system, and lower it to the fully lowered position.
6.
Rearrange the PIC cables in the cable management system.
Figure 133: Installing the Front Air Filter
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 Cooling System Description on page 39
•
Troubleshooting the T1600 Cooling System on page 543
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
•
Maintaining the T1600 Air Filters on page 510
Related
Documentation
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 Cooling System Description on page 39
•
Troubleshooting the T1600 Cooling System on page 543
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
Copyright © 2019, Juniper Networks, Inc.
315
T1600 Core Router Hardware Guide
•
Maintaining the T1600 Air Filters on page 510
Replacing the T1600 Rear Air Filter
1.
Removing a Rear T1600 Air Filter on page 316
2.
Installing the T1600 Rear Air Filter on page 318
Removing a Rear T1600 Air Filter
The rear air filter is located at the left rear edge of the chassis. The rear air filter weighs less than 1 lb (0.5 kg).
To remove the rear air filter:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Loosen the captive screws at the top, center, and bottom of the air filter, using a
Phillips (+) screwdriver, number 2.
3.
Grasp the air filter cover by the captive screws, and pull firmly to remove the cover and honeycomb assembly from the chassis (see
).
4.
Press the filter element inward until it clears the hooks at the top and bottom of the air filter slot, then push it to the left to unseat it.
5.
Move the tabs on the filter element to a horizontal position.
6.
Grasp the tabs on the filter element and carefully pull it straight out from the chassis
(see
).
316 Copyright © 2019, Juniper Networks, Inc.
Figure 134: Removing the Rear Air Filter
Chapter 26: Replacing Chassis Components
Copyright © 2019, Juniper Networks, Inc.
317
T1600 Core Router Hardware Guide
Figure 135: Removing the Rear Air Filter Element
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 Cooling System Description on page 39
•
Troubleshooting the T1600 Cooling System on page 543
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
•
Maintaining the T1600 Air Filters on page 510
Installing the T1600 Rear Air Filter
To install the rear air filter (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Holding the filter by the tabs, carefully push the filter all the way into the air filter slot.
3.
Holding the filter all the way in, push it to the right side of the slot until it is held in place behind the hooks.
318 Copyright © 2019, Juniper Networks, Inc.
Chapter 26: Replacing Chassis Components
4.
Move the tabs to a vertical position.
5.
Place the right edge of the honeycomb against the flange of the air filter slot.
6.
Line up the holes at the top, center, and bottom of the honeycomb with the pins in the slot, and press the honeycomb into place.
7.
Replace the air filter cover.
8.
Firmly tighten the captive screws at the top, center, and bottom of the filter cover to secure it to the chassis, using a Phillips (+) screwdriver, number 2.
Figure 136: Installing the Rear Air Filter
See Also •
T1600 Cooling System Description on page 39
•
Troubleshooting the T1600 Cooling System on page 543
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
•
Maintaining the T1600 Fan Trays on page 512
Copyright © 2019, Juniper Networks, Inc.
319
T1600 Core Router Hardware Guide
Replacing the T1600 Alarm Relay Wires
1.
Removing the T1600 Alarm Relay Wires on page 320
2.
Installing the T1600 Alarm Relay Wires on page 322
Removing the T1600 Alarm Relay Wires
To remove the wires connected to an alarm-reporting device:
1.
Disconnect the existing wire at the external device.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Using a 2.5-mm flat-blade screwdriver, loosen the small screws on the face of the terminal block and remove the block from the relay contact.
4.
Using the 2.5-mm flat-blade screwdriver, loosen the small screws on the side of the terminal block. Remove existing wires from the slots in the front of the block.
320 Copyright © 2019, Juniper Networks, Inc.
Figure 137: CIP
HOST
0
ETHERNET
ACT 0
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
HOST
1
ETHERNET
ACT 1
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
RED ALARM
NC
C
NO
NC
C
NO
YELLOW
ALARM
Copyright © 2019, Juniper Networks, Inc.
Chapter 26: Replacing Chassis Components
321
T1600 Core Router Hardware Guide
Figure 138: Alarm Relay Contacts on the CIP
Installing the T1600 Alarm Relay Wires
To connect the router to external alarm-reporting devices, attach wires to the RED ALARM and YELLOW ALARM relay contacts on the CIP. A system condition that triggers the red or yellow alarm LED on the craft interface also activates the corresponding alarm relay contact.
The terminal blocks that plug into the alarm relay contacts are supplied with the router.
They accept wire of any gauge between 28 AWG and 14 AWG (0.08 and 2.08 mm
2
), which is not provided. Use the gauge of wire appropriate for the external device you are connecting.
To connect the wires to an alarm-reporting device::
1.
Prepare the required length of replacement wire with gauge between 28 AWG and 14
AWG (0.08 and 2.08 mm
2
).
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Insert the replacement wires into the slots in the front of the block. Using a 2.5-mm flat-blade screwdriver, tighten the screws to secure the wire.
4.
Plug the terminal block into the relay contact and use a 2.5-mm flat-blade screwdriver to tighten the screws on the face of the block.
5.
Attach the other end of the wires to the external device.
See Also •
Overview of Connecting the T1600 Router to External Devices on page 235
•
T1600 Connector Interface Panel (CIP) Description on page 27
•
T1600 Alarm Messages Overview on page 542
322 Copyright © 2019, Juniper Networks, Inc.
Chapter 26: Replacing Chassis Components
Replacing a T1600 Console or Auxiliary Cable
To replace a serial cable connected to a management console or auxiliary device:
1.
Removing a T1600 Console or Auxiliary Cable on page 323
2.
Installing a T1600 Console or Auxiliary Cable on page 325
Removing a T1600 Console or Auxiliary Cable
To remove a serial cable connected to a management console or auxiliary device (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the site ESD points on the chassis.
2.
Turn off the power to the console or auxiliary device.
3.
Unscrew the screws that secure the cable connector to the port, using a 2.5-mm flat-blade screwdriver if necessary.
4.
Pull the cable connector straight out of the port.
5.
Disconnect the cable from the console or auxiliary device.
Copyright © 2019, Juniper Networks, Inc.
323
T1600 Core Router Hardware Guide
Figure 139: DB-9 Port on the CIP
HOST
0
ETHERNET
ACT 0
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
HOST
1
ETHERNET
ACT 1
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
RED ALARM
NC
C
NO
NC
C
NO
YELLOW
ALARM
See Also •
T1600 Connector Interface Panel (CIP) Description on page 27
•
T1600 Preventing Electrostatic Discharge Damage on page 588
324 Copyright © 2019, Juniper Networks, Inc.
Chapter 26: Replacing Chassis Components
Installing a T1600 Console or Auxiliary Cable
The AUXILIARY port and CONSOLE port on the CIP both accept an RS-232 (EIA-232_ serial cable with DB-9 connectors.
To connect a management console or auxiliary device:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the site ESD points on the chassis.
2.
Connect one end of the replacement cable into the appropriate CONSOLE or AUXILIARY port. The ports labeled HOST 0 connect to the Routing Engine in the upper Routing
Engine slot ( RE0 ), and the ports labeled HOST 1 connect to the Routing Engine in the lower Routing Engine slot ( RE1 ).
3.
Using a 2.5-mm flat-blade screwdriver, tighten the screws on the connector.
4.
Plug the other end of the cable into the device's serial port.
See Also •
T1600 Connector Interface Panel (CIP) Description on page 27
•
Connecting the T1600 Router to a Management Console or Auxiliary Device on page 237
•
Overview of Connecting the T1600 Router to External Devices on page 235
•
T1600 Routing Engine Interface Cable and Wire Specifications on page 169
•
T1600 DB-9 Connector Pinouts for the Routing Engine AUXILIARY and CONSOLE Ports on page 170
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Related
Documentation
•
T1600 Connector Interface Panel (CIP) Description on page 27
•
Connecting the T1600 Router to a Management Console or Auxiliary Device on page 237
•
T1600 Routing Engine Interface Cable and Wire Specifications on page 169
•
T1600 DB-9 Connector Pinouts for the Routing Engine AUXILIARY and CONSOLE Ports on page 170
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Replacing a T1600 Management Ethernet Cable
1.
Removing a T1600 Management Ethernet Cable on page 326
2.
Installing a T1600 Management Ethernet Cable on page 327
Copyright © 2019, Juniper Networks, Inc.
325
T1600 Core Router Hardware Guide
Removing a T1600 Management Ethernet Cable
1.
Press the tab on the connector and pull the connector straight out of the ETHERNET port.
shows the connector.
2.
Disconnect the cable from the network device.
Figure 140: Ethernet Cable Connectors
326 Copyright © 2019, Juniper Networks, Inc.
Chapter 26: Replacing Chassis Components
Figure 141: Ethernet Port on CIP
HOST
0
ETHERNET
ACT 0
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
HOST
1
ETHERNET
ACT 1
YEL = 10M
GRN = 100M
CONSOLE
AUXILIARY
RED ALARM
NC
C
NO
NC
C
NO
YELLOW
ALARM
Installing a T1600 Management Ethernet Cable
1.
Plug one end of the replacement cable into the appropriate ETHERNET port.
The ports labeled HOST 0 connect to the Routing Engine in the upper Routing Engine slot ( RE0 ), and the ports labeled HOST 1 connect to the Routing Engine in the lower Routing
Engine slot ( RE1 ).
2.
Plug the other end of the cable into the network device.
Copyright © 2019, Juniper Networks, Inc.
327
T1600 Core Router Hardware Guide
Related
Documentation
•
T1600 Connector Interface Panel (CIP) Description on page 27
•
Connecting the T1600 Router to a Network for Out-of-Band Management on page 239
•
T1600 Routing Engine Interface Cable and Wire Specifications on page 169
•
T1600 RJ-45 Connector Pinouts for the Routing Engine ETHERNET Port on page 170
Replacing a T1600 CIP
1.
Removing a T1600 CIP on page 328
2.
Installing a T1600 CIP on page 329
Removing a T1600 CIP
The CIP is located to the left side of the FPC card cage. It houses the Routing Engine interface ports, which accept connections to external management and alarm-reporting devices.
The CIP is hot-pluggable. It weighs approximately 8 lb (3.6 kg). When the CIP is removed, you cannot control or communicate with the router using an external device.
To remove the CIP (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the site ESD points on the chassis.
2.
Disconnect any external devices connected to the CIP.
3.
Loosen the captive screws at the top and bottom of the CIP faceplate.
4.
Grasp the handle on the CIP faceplate and carefully pull the CIP straight out of the chassis.
CAUTION: Be sure to slide the CIP straight within the slot to avoid damaging the connector pins on the front of the midplane.
328 Copyright © 2019, Juniper Networks, Inc.
Figure 142: Removing the CIP
Chapter 26: Replacing Chassis Components
See Also •
T1600 Connector Interface Panel (CIP) Description on page 27
•
T1600 Chassis Description on page 21
Installing a T1600 CIP
To install the CIP (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the CIP handle with one hand and hold the bottom edge of the CIP with the other hand to support its weight.
Copyright © 2019, Juniper Networks, Inc.
329
T1600 Core Router Hardware Guide
NOTE: The components on the CIP are on the left side of the board, unlike the components of an FPC, which are on the right side. Verify that the components are on the left before inserting the CIP.
3.
Insert the CIP into the leftmost slot of the FPC card cage, carefully aligning the top and bottom of the CIP with the guides in the card cage.
4.
Carefully push the CIP straight into the chassis until it contacts the midplane.
5.
Tighten the screws at the top and bottom of the CIP faceplate.
6.
Reattach any external devices connected to the CIP.
CAUTION: Be sure to slide the CIP straight within the slot to avoid damaging the connector pins on the front of the midplane.
7.
To verify that the CIP is installed correctly, plug an Ethernet cable into the Ethernet port on the CIP. If the host module is operational, the ACTIVE LED blinks to indicate
Ethernet activity. If you can run the CLI, the CIP is installed correctly.
330 Copyright © 2019, Juniper Networks, Inc.
Figure 143: Installing a CIP
Chapter 26: Replacing Chassis Components
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 Connector Interface Panel (CIP) Description on page 27
•
T1600 Chassis Description on page 21
Related
Documentation
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 Routing Engine Interface Cable and Wire Specifications on page 169
•
Maintaining the T1600 Routing Engines on page 521
•
Overview of Connecting the T1600 Router to External Devices on page 235
Replacing the T1600 Craft Interface
The craft interface is located on the front of the chassis above the FPC card cage (see
). The craft interface is hot-insertable and hot-removable. When you install the craft interface, allow several minutes for the display to reflect the current state of the router.
1.
Removing the T1600 Craft Interface on page 332
2.
Installing the T1600 Craft Interface on page 332
Copyright © 2019, Juniper Networks, Inc.
331
T1600 Core Router Hardware Guide
Removing the T1600 Craft Interface
Before you remove the craft interface, remove the front upper fan tray. To remove the craft interface, see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Completely loosen the screws at the four corners of the craft interface.
3.
Insert the blade of a flat-blade screwdriver into the slot on one side of the craft interface, then gently pry that side out from the chassis.
4.
Insert the blade of a flat-blade screwdriver into the slot on the other side of the craft interface, then gently pry that side out from the chassis.
5.
Grasp the craft interface by the top and bottom edges and carefully pull it straight out of the chassis.
Figure 144: Removing the Craft Interface
See Also •
T1600 Craft Interface Description on page 33
•
T1600 Craft Interface Alarm LEDs and ACO/LT Button on page 35
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Installing the T1600 Craft Interface
To install the craft interface (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
332 Copyright © 2019, Juniper Networks, Inc.
Chapter 26: Replacing Chassis Components
2.
Grasping the craft interface by the top and bottom edges, press it into place.
3.
Tighten the screws at the corners of the craft interface.
NOTE: When you install the craft interface in an operating router, allow several minutes for the LEDs on the craft interface to reflect the current state of the router.
After you install the replacement craft interface, immediately reinstall the upper front fan tray.
Figure 145: Installing a Replacement Craft Interface
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 Craft Interface Description on page 33
•
T1600 Craft Interface Alarm LEDs and ACO/LT Button on page 35
Related
Documentation
•
T1600 Craft Interface Description on page 33
•
T1600 Craft Interface Alarm LEDs and ACO/LT Button on page 35
Replacing a T1600 SCG
1.
Removing a T1600 SCG on page 333
2.
Installing the T1600 SCG on page 334
Removing a T1600 SCG
The router can have one or two SCGs installed. The SCGs are located in the upper rear of the chassis, above the control boards and Routing Engines. Each SCG weighs approximately 1.9 lb (0.9 kg).
Copyright © 2019, Juniper Networks, Inc.
333
T1600 Core Router Hardware Guide
A nonredundant SCG is hot-pluggable. For redundant SCGs, the master SCG is hot-pluggable. The backup SCG is hot-removable and hot-insertable if the master SCG is functioning. Removing the backup SCG does not affect the functioning of the router.
Taking the master SCG offline might result in a brief loss of SONET clock lock while the backup SCG becomes the master.
To remove an SCG (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Press the online/offline button on the SCG faceplate and hold it down until the LED goes out (about 5 seconds).
4.
Loosen the captive screws on the edges of the SCG faceplate.
5.
Grasp the SCG by the handle on the faceplate and slide it out of the chassis.
6.
Place the SCG on the antistatic mat.
Figure 146: Removing an SCG
See Also •
Maintaining the T1600 SCGs on page 530
•
T1600 SONET Clock Generators Description on page 30
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Installing the T1600 SCG
To install a replacement SCG (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Carefully align the sides of the SCG with the guides in the SCG slot.
334 Copyright © 2019, Juniper Networks, Inc.
Chapter 26: Replacing Chassis Components
3.
Grasp the SCG by its handle and slide it straight into the chassis until it contacts the midplane.
4.
Tighten the captive screws on the corners of the SCG faceplate.
5.
To bring the SCG online, press the online/offline button until the green OK LED lights.
6.
To verify that the SCG is installed correctly and is functioning normally, check the
LEDs on the SCG faceplate. The green OK LED should light steadily. If the SCG is master, the blue MASTER LED should also light steadily.
To check the status of the SCGs, use the following CLI command: user@host> show chassis environment scg
For more information about using the CLI, see the Junos OS manuals.
Figure 147: Installing an SCG
See Also •
Maintaining the T1600 SCGs on page 530
•
T1600 SONET Clock Generators Description on page 30
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Related
Documentation
•
Maintaining the T1600 SCGs on page 530
•
T1600 SONET Clock Generators Description on page 30
Copyright © 2019, Juniper Networks, Inc.
335
T1600 Core Router Hardware Guide
336 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 27
Replacing Cooling System Components
•
Replacing the T1600 Standard Lower Front Fan Tray on page 337
•
Replacing the T1600 Standard Upper Front Fan Tray on page 339
•
Replacing the T1600 Rear Fan Tray on page 341
•
Upgrading to the T1600 Quiet Fan Trays on page 345
•
Replacing the T1600 Quiet Lower Front Fan Tray on page 352
•
Replacing the T1600 Quiet Upper Front Fan Tray on page 355
•
Replacing the T1600 Quiet Rear Fan Tray on page 357
•
Replacing the T1600 Lower Front Fan Tray (FANTRAY-T4000) on page 360
•
Replacing the T1600 Upper Front Fan Tray (FANTRAY-T4000) on page 362
Replacing the T1600 Standard Lower Front Fan Tray
The lower front fan tray is located below the front air filter. Each standard front fan tray weighs about 18.6 lb (8.4 kg). The fan trays are hot-insertable and hot-removable. The standard upper and lower fan trays are interchangeable with each other.
1.
Removing the T1600 Standard Lower Front Fan Tray on page 337
2.
Installing the T1600 Standard Lower Front Fan Tray on page 338
Removing the T1600 Standard Lower Front Fan Tray
1.
Attach an electrostatic discharge (ESD) grounding strap to your wrist, and connect the strap to one of the ESD points on the chassis.
2.
Unwrap any PIC cables from the spools on the front cable management system and remove the cables from the tray. Arrange the cables so that they do not block the front cable management system and tray, and secure them with temporary fasteners so that they are not supporting their own weight as they hang from the connector.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
Copyright © 2019, Juniper Networks, Inc.
337
T1600 Core Router Hardware Guide
3.
Simultaneously pull the two releases on the front cable management system. Lift it up and outward to lock it in place to access the lower fan tray.
4.
Rearrange the PIC cables in the front cable management system. For more information about proper cable arrangement, see
“Maintaining T1600 PICs and PIC Cables” on page 523
.
5.
Loosen the captive screws on the corners of the fan tray faceplate.
6.
Grasp the handles and pull the fan tray halfway out of the chassis.
WARNING: To avoid injury, keep tools and your fingers away from the fans as you slide the fan tray out of the chassis. The fans might still be spinning.
7.
When the fans stop spinning, place one hand under the fan tray to support it and pull the fan tray completely out of the chassis.
See Also •
T1600 Cooling System Description on page 39
•
Troubleshooting the T1600 Cooling System on page 543
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
•
Maintaining the T1600 Fan Trays on page 512
Installing the T1600 Standard Lower Front Fan Tray
To install a standard lower front fan tray:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the fan tray by its handles and insert it straight into the chassis.
3.
Tighten the captive screws on each side of the fan tray faceplate to secure it in the chassis.
4.
Unlock the front cable management system and lower it to the fully lowered position.
5.
Rearrange the PIC cables in the front cable management system. For more information about proper cable arrangement, see
“Maintaining T1600 PICs and PIC Cables” on page 523
.
See Also •
T1600 Cooling System Description on page 39
338 Copyright © 2019, Juniper Networks, Inc.
Chapter 27: Replacing Cooling System Components
•
Troubleshooting the T1600 Cooling System on page 543
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
•
Maintaining the T1600 Fan Trays on page 512
Related
Documentation
•
T1600 Cooling System Description on page 39
•
Troubleshooting the T1600 Cooling System on page 543
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
•
Maintaining the T1600 Fan Trays on page 512
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Replacing the T1600 Standard Upper Front Fan Tray
The upper front fan tray is located above the FPC card cage. Each standard front fan tray weighs about 18.6 lb (8.4 kg). The fan trays are hot-insertable and hot-removable. The standard upper and lower fan trays are interchangeable with each other.
1.
Removing the T1600 Standard Upper Front Fan Tray on page 339
2.
Installing the T1600 Standard Upper Front Fan Tray on page 340
Removing the T1600 Standard Upper Front Fan Tray
To remove a standard upper front fan tray (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Loosen the captive screws on the corners of the fan tray faceplate.
3.
Grasp the handles and pull the fan tray halfway out of the chassis.
WARNING: To avoid injury, keep tools and your fingers away from the fans as you slide the fan tray out of the chassis. The fans might still be spinning.
4.
When the fans stop spinning, place one hand under the fan tray to support it and pull the fan tray completely out of the chassis.
Copyright © 2019, Juniper Networks, Inc.
339
T1600 Core Router Hardware Guide
Figure 148: Removing a Standard Upper Front Fan Tray
See Also •
T1600 Cooling System Description on page 39
•
Troubleshooting the T1600 Cooling System on page 543
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
•
Maintaining the T1600 Fan Trays on page 512
Installing the T1600 Standard Upper Front Fan Tray
To install a standard upper front fan tray (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the fan tray by its handles and insert it straight into the chassis.
3.
Tighten the captive screws on each side of the fan tray faceplate to secure it in the chassis.
340 Copyright © 2019, Juniper Networks, Inc.
Figure 149: Installing an Upper Front Fan Tray
Chapter 27: Replacing Cooling System Components
See Also •
T1600 Cooling System Description on page 39
•
Troubleshooting the T1600 Cooling System on page 543
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
•
Maintaining the T1600 Fan Trays on page 512
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Related
Documentation
•
T1600 Cooling System Description on page 39
•
Troubleshooting the T1600 Cooling System on page 543
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
•
Maintaining the T1600 Fan Trays on page 512
Replacing the T1600 Rear Fan Tray
The rear fan tray is mounted vertically on the right side of the rear of the chassis. The rear fan tray contains eight fans, and is not interchangeable with the front fan trays. The
FAN-REAR-TX-T640 rear fan tray weighs about 10 lb (4.5 kg). The FAN-REAR-TXP-LCC rear fan tray weighs about 10 lb (4.5 kg). The FAN-R-TXP-3D-LCC rear fan tray weighs about 13 lb (5.9 kg).
1.
Removing the T1600 Rear Fan Tray on page 342
2.
Installing the T1600 Rear Fan Tray on page 343
Copyright © 2019, Juniper Networks, Inc.
341
T1600 Core Router Hardware Guide
Removing the T1600 Rear Fan Tray
CAUTION: To maintain proper cooling, do not operate the router with the rear fan tray removed for more than 1 minute.
To remove the rear fan tray (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point.
2.
Loosen the captive screws on the top and bottom of the fan tray faceplate.
3.
Grasp the handles, and pull the fan tray halfway out of the chassis.
4.
Wait for the fans to stop spinning.
5.
After the fans stop spinning, place one hand under the fan tray to support it, and pull the fan tray completely out of the chassis.
342 Copyright © 2019, Juniper Networks, Inc.
Figure 150: Removing the Rear Fan Tray
Chapter 27: Replacing Cooling System Components
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Installing the T1600 Rear Fan Tray on page 343
•
Maintaining the T1600 Fan Trays on page 512
•
Troubleshooting the T1600 Cooling System on page 543
Installing the T1600 Rear Fan Tray
To install a replacement rear fan tray (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the fan tray by its handles and insert it straight into the chassis.
Copyright © 2019, Juniper Networks, Inc.
343
T1600 Core Router Hardware Guide
3.
Tighten the captive screws on the fan tray faceplate to secure it in the chassis, using a Phillips (+) screwdriver, number 2.
Figure 151: Installing the Rear Fan Tray
344
See Also •
T1600 Cooling System Description on page 39
•
Troubleshooting the T1600 Cooling System on page 543
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
•
Maintaining the T1600 Fan Trays on page 512
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Related
Documentation
•
T1600 Cooling System Description on page 39
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
Copyright © 2019, Juniper Networks, Inc.
Chapter 27: Replacing Cooling System Components
•
Maintaining the T1600 Fan Trays on page 512
•
Troubleshooting the T1600 Cooling System on page 543
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Upgrading to the T1600 Quiet Fan Trays
1.
Upgrading the Standard Lower Front Fan Tray to a Quiet Lower Front Fan
2.
Removing the Standard Upper Front Fan Tray on page 346
3.
Removing the Craft Interface on page 347
4.
Installing the Air Deflector and Craft Interface on page 348
5.
Installing the Quiet Upper Front Fan Tray on page 349
6.
Upgrading the Standard Rear Fan Tray to a Quiet Rear Fan Tray on page 350
Upgrading the Standard Lower Front Fan Tray to a Quiet Lower Front Fan Tray
Each standard front fan tray weighs about 18.6 lb (8.4 kg). Each quiet front fan tray weighs about 17.8 lb (8.1 kg).
1.
Attach an electrostatic discharge (ESD) grounding strap to your wrist, and connect the strap to one of the ESD points on the chassis.
2.
Unwrap any PIC cables from the spools on the front cable management system and remove the cables from the tray. Arrange the cables so that they do not block the front cable management system and tray, and secure them with temporary fasteners so that they are not supporting their own weight as they hang from the connector.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
3.
Simultaneously pull the two releases on the front cable management system. Lift it up and outward to lock it in place to access the lower fan tray.
4.
Rearrange the PIC cables in the front cable management system. For more information about proper cable arrangement, see
“Maintaining T1600 PICs and PIC Cables” on page 523
.
5.
Loosen the captive screws on the corners of the standard lower front fan tray faceplate.
6.
Grasp the handles and pull the standard lower front fan tray halfway out of the chassis.
Copyright © 2019, Juniper Networks, Inc.
345
T1600 Core Router Hardware Guide
WARNING: To avoid injury, keep tools and your fingers away from the fans as you slide the fan tray out of the chassis. The fans might still be spinning.
7.
Wait for the fans to stop spinning.
8.
After the fans stop spinning, place one hand under the standard lower front fan tray to support it and pull the fan tray completely out of the chassis.
9.
Locate the fan tray labeled FAN-T-FBOT-S LOWER FANTRAY .
10.
Press the two latches located on each side of the quiet lower front fan tray up, and insert the quiet lower front fan tray straight into the lower front fan tray slot. See
11.
Tighten the captive screws on each side of the quiet lower front fan tray faceplate to secure it in the chassis.
12.
Unlock the front cable management system and lower it to the fully lowered position.
13.
Rearrange the PIC cables in the front cable management system. For more information about proper cable arrangement, see
“Maintaining T1600 PICs and PIC Cables” on page 523
.
Figure 152: Installing a Quiet Lower Front Fan Tray
Removing the Standard Upper Front Fan Tray
The upper front fan tray is located above the FPC card cage. Each standard front fan tray weighs about 18.6 lb (8.4 kg). The fan trays are hot-removable.
346 Copyright © 2019, Juniper Networks, Inc.
Chapter 27: Replacing Cooling System Components
To remove a standard upper front fan tray (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Loosen the captive screws on the corners of the fan tray faceplate.
3.
Grasp the handles and pull the fan tray halfway out of the chassis.
WARNING: To avoid injury, keep tools and your fingers away from the fans as you slide the fan tray out of the chassis. The fans might still be spinning.
4.
Wait for the fans to stop spinning.
5.
After the fans stop spinning, place one hand under the fan tray to support it and pull the fan tray completely out of the chassis.
Figure 153: Removing a Standard Upper Front Fan Tray
Removing the Craft Interface
The craft interface is located on the front of the chassis above the FPC card cage. The craft interface is hot-removable. To remove the craft interface (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Completely loosen the screws at the four corners of the craft interface.
3.
Insert the blade of a flat-blade screwdriver into the slot on one side of the craft interface, then gently pry that side out from the chassis.
Copyright © 2019, Juniper Networks, Inc.
347
T1600 Core Router Hardware Guide
4.
Insert the blade of a flat-blade screwdriver into the slot on the other side of the craft interface, then gently pry that side out from the chassis.
5.
Grasp the craft interface by the top and bottom edges and carefully pull it straight out of the chassis.
6.
Remove the Craft Interface Panel by loosening the four fasteners.
Figure 154: Removing the Craft Interface
Installing the Air Deflector and Craft Interface
NOTE: If an air deflector is already installed, installing another air deflector is not required.
To install the T1600 air deflector:
1.
Slide in the air deflector. See
for proper orientation of air deflector. Four holes align with the four standoffs used for mounting the craft interface.
2.
Replace the craft interface and secure with the four fasteners.
Figure 155: Installing the Air Deflector
Air deflector
348 Copyright © 2019, Juniper Networks, Inc.
Chapter 27: Replacing Cooling System Components
Installing the Quiet Upper Front Fan Tray
The upper front fan tray is located above the FPC card cage. Each quiet front fan tray weighs about 17.8 lb (8.1 kg). The fan trays are hot-insertable. The quiet upper and lower fan trays are not interchangeable with each other. The quiet upper front fan tray is labeled
FAN-T-FTOP-S UPPER FANTRAY .
To install a quiet upper front fan tray (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Locate the fan tray labeled FAN-T-FTOP-S UPPER FANTRAY .
3.
Press the two latches located on each side of the quiet upper front fan tray up, and insert the quiet upper front fan tray straight into the upper front fan tray slot.
4.
Tighten the captive screws on each side of the fan tray faceplate to secure it in the chassis.
Figure 156: Installing the Quiet Upper Front Fan Tray
Copyright © 2019, Juniper Networks, Inc.
349
T1600 Core Router Hardware Guide
Upgrading the Standard Rear Fan Tray to a Quiet Rear Fan Tray
CAUTION: To maintain proper cooling, do not operate the router with the rear fan tray removed for more than 1 minute.
To upgrade the rear fan tray (see
) and
:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Loosen the captive screws on the top and bottom of the standard fan tray faceplate.
3.
Grasp the handles on the faceplate, and pull the standard rear fan tray halfway out of the chassis.
WARNING: To avoid injury, keep tools and your fingers away from the fans as you slide the fan tray out of the chassis. The fans might still be spinning.
4.
After the fans stop spinning, place one hand under the fan tray to support it, and pull the standard fan tray completely out of the chassis.
5.
Locate the quiet rear fan tray labeled REAR FANTRAY FAN-R-S .
6.
Grasp the quiet rear fan tray by its handles and insert it straight into the chassis.
7.
Tighten the captive screws on the quiet rear fan tray faceplate to secure it in the chassis, using a Phillips (+) screwdriver, number 2.
350 Copyright © 2019, Juniper Networks, Inc.
Chapter 27: Replacing Cooling System Components
Figure 157: Removing the Standard Rear Fan Tray
Copyright © 2019, Juniper Networks, Inc.
351
T1600 Core Router Hardware Guide
Figure 158: Installing the Quiet Rear Fan Tray
Related
Documentation
•
T1600 Cooling System Description on page 39
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Replacing the T1600 Quiet Lower Front Fan Tray
The lower front fan tray is located below the front air filter. Each quiet front fan tray weighs about 17.8 lb (8.1 kg). The fan trays are hot-insertable and hot-removable. The quiet upper and lower fan trays are not interchangeable with each other. The quiet lower front fan tray is labeled FAN-T-FBOT-S LOWER FANTRAY .
1.
Removing the T1600 Quiet Lower Front Fan Tray on page 353
2.
Installing the T1600 Quiet Lower Front Fan Tray on page 354
352 Copyright © 2019, Juniper Networks, Inc.
Chapter 27: Replacing Cooling System Components
Removing the T1600 Quiet Lower Front Fan Tray
To remove the quiet lower front fan tray:
1.
Attach an electrostatic discharge (ESD) grounding strap to your wrist, and connect the strap to one of the ESD points on the chassis.
2.
Unwrap any PIC cables from the spools on the front cable management system and remove the cables from the tray. Arrange the cables so that they do not block the front cable management system and tray, and secure them with temporary fasteners so that they are not supporting their own weight as they hang from the connector.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
3.
Simultaneously pull the two releases on the front cable management system. Lift it up and outward to lock it in place to access the lower fan tray.
4.
Rearrange the PIC cables in the front cable management system. For more information about proper cable arrangement, see
“Maintaining T1600 PICs and PIC Cables” on page 523
.
5.
Loosen the captive screws on the corners of the fan tray faceplate.
6.
Grasp the handles on the faceplate, and pull the fan tray out of the chassis approximately 1 to 3 inches.
WARNING: To avoid injury, keep tools and your fingers away from the fans as you slide the fan tray out of the chassis. The fans might still be spinning.
7.
Wait for all fans to stop spinning.
WARNING: Rotating blades can cause serious injury. Allow fan blades to stop before you remove the fan tray.
8.
After the fans stop spinning, press up on the two latches located on each side of the fan tray to release the fan tray from the chassis (see
9.
Place one hand under the fan tray to support it and pull the fan tray completely out of the chassis.
Copyright © 2019, Juniper Networks, Inc.
353
T1600 Core Router Hardware Guide
Figure 159: Removing the Quiet Lower Front Fan Tray
Installing the T1600 Quiet Lower Front Fan Tray
To install a quiet lower front fan tray see
:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Locate a replacement quiet lower fan tray labeled FAN-T-FBOT-S LOWER FANTRAY .
3.
Press the two latches located on each side of the quiet lower front fan tray up, and insert the quiet lower front fan tray straight into the lower front fan tray slot.
4.
Tighten the captive screws on each side of the quiet lower front fan tray faceplate to secure it to the chassis.
5.
Unlock the front cable management system and lower it to the fully lowered position.
6.
Rearrange the PIC cables in the front cable management system. For more information about proper cable arrangement, see
“Maintaining T1600 PICs and PIC Cables” on page 523
.
Figure 160: Installing the Quiet Lower Front Fan Tray
354 Copyright © 2019, Juniper Networks, Inc.
Chapter 27: Replacing Cooling System Components
See Also •
T1600 Cooling System Description on page 39
•
Replacing the T1600 Quiet Rear Fan Tray on page 357
•
Replacing the T1600 Quiet Upper Front Fan Tray on page 355
•
Troubleshooting the T1600 Cooling System on page 543
•
Upgrading to the T1600 Quiet Fan Trays on page 345
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Replacing the T1600 Quiet Upper Front Fan Tray
The upper front fan tray is located above the FPC card cage. Each quiet front fan tray weighs about 17.8 lb (8.1 kg). The fan trays are hot-insertable and hot-removable. The quiet upper and lower fan trays are not interchangeable with each other. The quiet upper front fan tray is labeled FAN-T-FTOP-S UPPER FANTRAY .
1.
Removing the Quiet Upper Front Fan Tray on page 355
2.
Installing the Quiet Upper Front Fan Tray on page 356
Removing the Quiet Upper Front Fan Tray
To remove a quiet upper front fan tray (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Loosen the captive screws on the corners of the fan tray faceplate.
3.
Grasp the handles on the faceplate, and pull the fan tray out of the chassis approximately 1 to 3 inches.
WARNING: To avoid injury, keep tools and your fingers away from the fans as you slide the fan tray out of the chassis. The fans might still be spinning.
4.
Wait for all fans to stop spinning.
WARNING: Rotating blades can cause serious injury. Allow fan blades to stop before you remove the fan tray.
Copyright © 2019, Juniper Networks, Inc.
355
T1600 Core Router Hardware Guide
5.
After the fans stop spinning, press up on the two latches located on each side of the fan tray to release the fan tray from the chassis (see
6.
Place one hand under the fan tray to support it and pull the fan tray completely out of the chassis.
Figure 161: Removing the Quiet Upper Front Fan Tray
Installing the Quiet Upper Front Fan Tray
To install a quiet upper front fan tray (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Locate a quiet upper front fan tray labeled FAN-T-FTOP-S UPPER FANTRAY .
3.
Press the two latches located on each side of the quiet upper front fan tray up, and insert the quiet upper front fan tray straight into the upper front fan tray slot.
4.
Tighten the captive screws on each side of the fan tray faceplate to secure it in the chassis.
356 Copyright © 2019, Juniper Networks, Inc.
Chapter 27: Replacing Cooling System Components
Figure 162: Installing the Quiet Upper Front Fan Tray
See Also •
T1600 Cooling System Description on page 39
•
Replacing the T1600 Quiet Rear Fan Tray on page 357
•
Replacing the T1600 Quiet Lower Front Fan Tray on page 352
•
Troubleshooting the T1600 Cooling System on page 543
•
Upgrading to the T1600 Quiet Fan Trays on page 345
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Replacing the T1600 Quiet Rear Fan Tray
The rear fan tray is mounted vertically on the right side of the rear of the chassis. The quiet rear fan tray contains eight fans, and is not interchangeable with the front fan trays.
The quiet rear fan tray must be used in conjunction with the quiet front fan trays. The quiet rear fan tray weighs about 10 lb (4.5 kg).
1.
Removing the Quiet Rear Fan Tray on page 357
2.
Installing the Quiet Rear Fan Tray on page 359
Removing the Quiet Rear Fan Tray
CAUTION: To maintain proper cooling, do not operate the router with the rear fan tray removed for more than 1 minute.
To remove the quiet rear fan tray (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point.
2.
Loosen the captive screws on the top and bottom of the fan tray faceplate.
Copyright © 2019, Juniper Networks, Inc.
357
T1600 Core Router Hardware Guide
3.
Grasp the handles on the faceplate, and pull the fan tray halfway out of the chassis.
WARNING: To avoid injury, keep tools and your fingers away from the fans as you slide the fan tray out of the chassis. The fans might still be spinning.
4.
Wait for all fans to stop spinning.
5.
After the fans stop spinning, place one hand under the fan tray to support it, and pull the fan tray completely out of the chassis.
Figure 163: Removing the Quiet Rear Fan Tray
358 Copyright © 2019, Juniper Networks, Inc.
Chapter 27: Replacing Cooling System Components
Installing the Quiet Rear Fan Tray
To install a replacement quiet rear fan tray (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Locate a replacement quiet rear fan tray labeled REAR FANTRAY FAN-R-S .
3.
Grasp the fan tray by its handles and insert it straight into the chassis.
4.
Tighten the captive screws on the fan tray faceplate to secure it in the chassis, using a Phillips (+) screwdriver, number 2.
Figure 164: Installing the Quiet Rear Fan Tray
Copyright © 2019, Juniper Networks, Inc.
359
T1600 Core Router Hardware Guide
See Also •
T1600 Cooling System Description on page 39
•
Replacing the T1600 Quiet Lower Front Fan Tray on page 352
•
Replacing the T1600 Quiet Upper Front Fan Tray on page 355
•
Troubleshooting the T1600 Cooling System on page 543
•
Upgrading to the T1600 Quiet Fan Trays on page 345
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Replacing the T1600 Lower Front Fan Tray (FANTRAY-T4000)
The lower front fan tray is located below the front air filter. Each front fan tray weighs about 20.4 lb (9.3 kg). The fan trays are hot-insertable and hot-removable. The upper and lower fan trays are interchangeable with each other.
1.
Removing the T1600 Lower Front Fan Tray (FANTRAY-T4000) on page 360
2.
Installing the T1600 Lower Front Fan Tray (FANTRAY-T4000) on page 361
Removing the T1600 Lower Front Fan Tray (FANTRAY-T4000)
To remove a lower front fan tray (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your wrist, and connect the strap to one of the ESD points on the chassis.
2.
Unwrap any PIC cables from the spools on the front cable management system, and remove the cables from the tray. Arrange the cables so that they do not block the front cable management system and tray, and secure them with temporary fasteners so that they are not supporting their own weight as they hang from the connector.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
3.
Simultaneously pull the two releases on the front cable management system. Lift it up and outward to lock it in place to access the lower fan tray.
4.
Rearrange the PIC cables in the front cable management system. For more information about proper cable arrangement, see
“Maintaining T1600 PICs and PIC Cables” on page 523
.
5.
Loosen the captive screws on the corners of the fan tray faceplate.
6.
Grasp the handles and pull the fan tray halfway out of the chassis.
360 Copyright © 2019, Juniper Networks, Inc.
Chapter 27: Replacing Cooling System Components
WARNING: To avoid injury, keep tools and your fingers away from the fans as you slide the fan tray out of the chassis. The fans might still be spinning.
7.
When the fans stop spinning, place one hand under the fan tray to support it and pull the fan tray completely out of the chassis.
Figure 165: Removing a Lower Front Fan Tray
FANTRAY-T4000
Installing the T1600 Lower Front Fan Tray (FANTRAY-T4000)
To install a lower front fan tray (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the fan tray by its handles and insert it straight into the chassis.
3.
Tighten the captive screws on each side of the fan tray faceplate to secure it in the chassis.
4.
Unlock the front cable management system and lower it to the fully lowered position.
5.
Rearrange the PIC cables in the front cable management system. For more information about proper cable arrangement, see
“Maintaining T1600 PICs and PIC Cables” on page 523
.
Copyright © 2019, Juniper Networks, Inc.
361
T1600 Core Router Hardware Guide
Figure 166: Installing a Lower Front Fan Tray
FANTRAY-T4000
Related
Documentation
•
T1600 Cooling System Description on page 39
•
Troubleshooting the T1600 Cooling System on page 543
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
•
Maintaining the T1600 Fan Trays on page 512
Replacing the T1600 Upper Front Fan Tray (FANTRAY-T4000)
The upper front fan tray is located above the FPC card cage. Each standard front fan tray weighs about 20.4 lb (9.3 kg). The fan trays are hot-insertable and hot-removable. The standard upper and lower fan trays are interchangeable with each other.
1.
Removing the T1600 Upper Front Fan Tray (FANTRAY-T4000) on page 362
2.
Installing the T1600 Upper Front Fan Tray (FANTRAY-T4000) on page 363
Removing the T1600 Upper Front Fan Tray (FANTRAY-T4000)
To remove an upper front fan tray (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Loosen the captive screws on the corners of the fan tray faceplate.
3.
Grasp the handles and pull the fan tray halfway out of the chassis.
WARNING: To avoid injury, keep tools and your fingers away from the fans as you slide the fan tray out of the chassis. The fans might still be spinning.
4.
When the fans stop spinning, place one hand under the fan tray to support it, and pull the fan tray completely out of the chassis.
362 Copyright © 2019, Juniper Networks, Inc.
Chapter 27: Replacing Cooling System Components
Figure 167: Removing an Upper Front Fan Tray
FANTRAY-T4000
T Series
FANTRAY-T4000
FANTRA
Y-T4000
See Also •
T1600 Cooling System Description on page 39
•
Troubleshooting the T1600 Cooling System on page 543
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
•
Maintaining the T1600 Fan Trays on page 512
Installing the T1600 Upper Front Fan Tray (FANTRAY-T4000)
To install an upper front fan tray (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the fan tray by its handles and insert it straight into the chassis.
Copyright © 2019, Juniper Networks, Inc.
363
T1600 Core Router Hardware Guide
3.
Tighten the captive screws on each side of the fan tray faceplate to secure it in the chassis.
Figure 168: Installing an Upper Front Fan Tray
T Series
FANTRAY-T4000
FANTRAY-T4000
See Also •
T1600 Cooling System Description on page 39
•
Troubleshooting the T1600 Cooling System on page 543
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
•
Maintaining the T1600 Fan Trays on page 512
Related
Documentation
•
T1600 Cooling System Description on page 39
•
Troubleshooting the T1600 Cooling System on page 543
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
•
Maintaining the T1600 Fan Trays on page 512
364 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 28
Replacing Host Subsystem Components
•
Taking the T1600 Host Subsystem Offline on page 365
•
Replacing a T1600 T-CB on page 368
•
Replacing a T1600 LCC-CB on page 370
•
Replacing a T1600 Routing Engine on page 374
•
Replacing a CompactFlash Card in a T1600 RE-C1800 Routing Engine on page 379
•
Replacing a DIMM Module in a T1600 Routing Engine on page 384
•
Replacing a PC Card in a T1600 Routing Engine on page 386
•
Replacing a Solid-State Disk in a T1600 RE-C1800 Routing Engine on page 388
Taking the T1600 Host Subsystem Offline
Before you replace a control board or a Routing Engine, you must take the host subsystem offline. The host subsystem is taken offline and brought online as a unit. Normally, if two host subsystems are installed in the router, RE0 functions as the master and RE1 functions as the backup.
explains the effect of taking the host subsystem offline.
Table 108: Effect of Taking the Host Subsystem Offline
Type of Host
Subsystem Effect of taking the Host Subsystem Offline
Nonredundant host subsystem
The router shuts down.
Backup host subsystem
The functioning of the router is not interrupted. The backup host subsystem is hot-removable and hot-insertable.
Copyright © 2019, Juniper Networks, Inc.
365
T1600 Core Router Hardware Guide
Table 108: Effect of Taking the Host Subsystem Offline (continued)
Type of Host
Subsystem Effect of taking the Host Subsystem Offline
Master host subsystem
The backup host subsystem becomes the master. The backup Routing
Engine assumes Routing Engine functions. The master host subsystem is hot-pluggable. Removal or failure of the master Routing Engine affects forwarding and routing based on the high availability configuration:
• Dual Routing Engines without any high availability features enabled—Traffic is interrupted while the Packet Forwarding Engine is reinitialized. All kernel and forwarding processes are restarted. When the switchover to the new master Routing Engine is complete, routing convergence takes place and traffic is resumed.
•
•
Graceful Routing Engine switchover (GRES) is enabled—Graceful
Routing Engine switchover preserves interface and kernel information.
Traffic is not interrupted. However, graceful Routing Engine switchover does not preserve the control plane. Neighboring routers detect that the router has restarted and react to the event in a manner prescribed by individual routing protocol specifications. To preserve routing without interruption during a switchover, graceful Routing Engine switchover must be combined with nonstop active routing.
Nonstop active routing is enabled (graceful Routing Engine switchover must be configured for nonstop active routing to be enabled)—Nonstop active routing supports Routing Engine switchover without alerting peer nodes that a change has occurred. Nonstop active routing uses the same infrastructure as graceful Routing Engine switchover to preserve interface and kernel information. However, nonstop active routing also preserves routing information and protocol sessions by running the routing protocol process (rpd) on both Routing Engines. In addition, nonstop active routing preserves TCP connections maintained in the kernel.
•
Nonstop active routing is supported on Junos OS Release 8.5 and later for standalone T1600 routers, Junos OS Release 10.0 and later for T1600 routers in a routing matrix.
Graceful restart is configured—Graceful restart provides extensions to routing protocols so that neighboring helper routers restore routing information to a restarting router. These extensions signal neighboring routers about the graceful restart and prevent the neighbors from reacting to the router restart and from propagating the change in state to the network during the graceful restart period. Neighbors provide the routing information that enables the restarting router to stop and restart routing protocols without causing network reconvergence. Neighbors are required to support graceful restart. The routing protocol process
(rpd) restarts. A graceful restart interval is required. For certain protocols, a significant change in the network can cause graceful restart to stop.
NOTE: Router performance might change if the backup Routing Engine's configuration differs from the former master's configuration. For the most predictable performance, configure the two Routing Engines identically, except for parameters unique to each Routing Engine.
366 Copyright © 2019, Juniper Networks, Inc.
Chapter 28: Replacing Host Subsystem Components
NOTE: For information about configuring graceful Routing Engine switchover
(GRES) and nonstop active routing, see the Junos OS High Availability Library
for Routing Devices.
To take a host subsystem offline:
1.
Determine whether the host subsystem is functioning as the master or as the backup, using one of the two following methods:
• Check the Routing Engine LEDs on the craft interface. If the green MASTER LED is lit, the corresponding host subsystem is functioning as the master.
• Issue the following CLI command. The master Routing Engine is designated Master in the Current state field: user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
...
2.
If the host subsystem is functioning as the master, switch it to backup using the CLI command: user@host> request chassis routing-engine master switch
3.
Halt the Routing Engine.
user@host> request system halt
Wait until a message appears on the console confirming that the operating system has halted.
The command shuts down the Routing Engine cleanly, so its state information is preserved.
NOTE: The SIBs might continue forwarding traffic for approximately 5 minutes after the request system halt command has been issued.
4.
On the console or other management device connected to the other Routing Engine, enter CLI operational mode and issue the following command.
user@host> request chassis cb offline slot n n is 0 or 1 for the slot number of the host subsystem being taken offline.
5.
Verify that the control board is offline:
Copyright © 2019, Juniper Networks, Inc.
367
T1600 Core Router Hardware Guide user@host> show chassis environment cb
Related
Documentation
•
Maintaining the T1600 Host Subsystem on page 520
•
T1600 Craft Interface Host Subsystem LEDs on page 36
• request system halt
• request chassis cb
• show chassis environment cb
Replacing a T1600 T-CB
1.
Removing a T1600 T-CB on page 368
2.
Installing a T1600 T-CB on page 369
Removing a T1600 T-CB
The backup T-CB is hot-removable and hot-insertable.
The router can have up to two T-CBs. They are located in the upper rear of the chassis in the slots marked CB0 and CB1 . Each weighs approximately 5 lb (2.3 kg).
CAUTION: Before you replace a T-CB, you must take the host subsystem offline. If there is only one host subsystem, taking the host subsystem offline shuts down the router. If the T-CB to be replaced is associated with the
Routing Engine currently functioning as the master Routing Engine, switch it to the backup before removing the T-CB. See
Subsystem Offline” on page 365
.
To remove a T-CB (see
):
1.
Take the host subsystem offline. See
“Taking the T1600 Host Subsystem Offline” on page 365
.
2.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
Loosen the captive screws (using a Phillips (+) screwdriver, number 2) on the ejector handles on both sides of the T-CB faceplate.
5.
Flip the ejector handles outward to unseat the T-CB.
6.
Grasp the ejector handles and slide the T-CB about halfway out of the chassis.
368 Copyright © 2019, Juniper Networks, Inc.
Chapter 28: Replacing Host Subsystem Components
7.
Place one hand underneath the T-CB to support it and slide it completely out of the chassis.
8.
Place the T-CB on the antistatic mat.
9.
If you are not replacing the T-CB now, install a blank panel over the empty slot.
Figure 169: Removing a T-CB
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Maintaining the T1600 Control Boards on page 511
•
T1600 T Series Control Boards (T-CBs) Description on page 75
Installing a T1600 T-CB
To install a T-CB (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Carefully align the sides of the T-CB with the guides inside the chassis.
3.
Slide the T-CB into the chassis, carefully ensuring that it is correctly aligned.
4.
Grasp both ejector handles, and press them inward to seat the T-CB.
5.
Tighten the captive screws on the ejector handles, using a Phillips (+) screwdriver, number 2.
6.
If power is applied to the Routing Engine and its corresponding T-CB is functioning normally, the T-CB comes online automatically. To verify that the T-CB is functioning normally, check the LEDs on its faceplate. The green OK LED should light steadily a few minutes after the T-CB is installed. If the FAIL LED is lit steadily, remove and install
Copyright © 2019, Juniper Networks, Inc.
369
T1600 Core Router Hardware Guide the T-CB again. If the FAIL LED still lights steadily, the T-CB is not functioning properly.
Contact your customer support representative.
To check the status of the T-CB, use the CLI command: user@host> show chassis environment cb
Figure 170: Installing a T-CB
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Maintaining the T1600 Control Boards on page 511
•
T1600 T Series Control Boards (T-CBs) Description on page 75
Related
Documentation
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Maintaining the T1600 Control Boards on page 511
•
T1600 T Series Control Boards (T-CBs) Description on page 75
Replacing a T1600 LCC-CB
1.
Removing a T1600 LCC-CB on page 371
2.
Installing a T1600 LCC-CB on page 372
370 Copyright © 2019, Juniper Networks, Inc.
Chapter 28: Replacing Host Subsystem Components
Removing a T1600 LCC-CB
The router can have up to two LCC-CBs. They are located in the upper rear of the chassis in the slots marked CB0 and CB1 . Each LCC-CB weighs approximately 5 lb (2.3 kg).
CAUTION: Before you replace an LCC-CB, you must take the host subsystem offline. If there is only one host subsystem, taking the host subsystem offline shuts down the router.
The backup LCC-CB is hot-removable and hot-insertable.
CAUTION: If the LCC-CB to be replaced is associated with the Routing Engine currently functioning as the master Routing Engine, switch it to the backup before removing the LCC-CB.
To remove an LCC-CB (see
):
1.
Take the host subsystem offline.
2.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
If the T1600 router is in a routing matrix, disconnect any cables that are plugged into the ports.
5.
Loosen the captive screws (using a Phillips (+) screwdriver, number 2) on the ejector handles on both sides of the LCC-CB faceplate.
6.
Flip the ejector handles outward to unseat the LCC-CB.
7.
Grasp the ejector handles and slide the LCC-CB about halfway out of the chassis.
8.
Place one hand underneath the LCC-CB to support it and slide it completely out of the chassis.
9.
Place the LCC-CB on the antistatic mat.
10.
If you are not replacing the LCC-CB now, install a blank panel over the empty slot.
Copyright © 2019, Juniper Networks, Inc.
371
T1600 Core Router Hardware Guide
Figure 171: Removing an LCC-CB
See Also •
T1600 Control Boards Description on page 74
•
Taking the T1600 Host Subsystem Offline on page 365
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Installing a T1600 LCC-CB
To install an LCC-CB (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Verify that the CHASSIS ID and M/S switches on the LCC-CB faceplate are set correctly for your configuration. If you are installing the LCC-CB in a standalone router, the M/S switch must be set to S and the CHASSIS ID configuration switch must be set to 0 .
NOTE: See Setting the Chassis ID and M/S Switch on the LCC-CB in the TX
Matrix Plus Router Hardware Guide for instructions to set the switches when installing the LCC-CB in a T1600 that is part of a routing matrix.
3.
Carefully align the sides of the LCC-CB with the guides inside the chassis.
4.
Slide the LCC-CB into the chassis, carefully ensuring that it is correctly aligned.
372 Copyright © 2019, Juniper Networks, Inc.
Chapter 28: Replacing Host Subsystem Components
5.
Grasp both ejector handles, and press them inward to seat the LCC-CB.
6.
Tighten the captive screws on the ejector handles, using a Phillips (+) screwdriver, number 2.
7.
If the T1600 router is in a routing matrix, reconnect any applicable cables that were previously plugged into the ports.
8.
Verify that the LCC-CB is functioning normally:
• Check the LEDs on the LCC-CB faceplate. The green OK LED should light steadily a few minutes after the LCC-CB is installed. If power is applied to the Routing Engine and its corresponding LCC-CB is functioning normally, the LCC-CB comes online automatically.
If the FAIL LED is lit steadily, remove and install the LCC-CB again. If the FAIL LED still lights steadily, the LCC-CB is not functioning properly. Contact your customer support representative.
• Use the show chassis environment cb to check the status of the LCC-CB.
Figure 172: Installing an LCC-CB
See Also •
T1600 Control Boards Description on page 74
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Copyright © 2019, Juniper Networks, Inc.
373
T1600 Core Router Hardware Guide
Related
Documentation
•
T1600 Control Boards Description on page 74
•
Taking the T1600 Host Subsystem Offline on page 365
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Replacing a T1600 Routing Engine
1.
Removing a T1600 Routing Engine on page 374
2.
Installing the T1600 Routing Engine on page 376
3.
Verifying the Installation of the T1600 Routing Engine on page 378
Removing a T1600 Routing Engine
The router can have one or two Routing Engines. They are located in the upper rear of the chassis in the slots marked RE0 and RE1 . Each Routing Engine can weigh up to
2.4 lb (1.1 kg). The backup Routing Engine is hot-removable and hot-insertable.
CAUTION: Before you replace a Routing Engine, you must take the host subsystem offline. If there is only one host subsystem, taking the host subsystem offline shuts down the router. If the Routing Engine to be replaced is currently functioning as the master Routing Engine, switch it to be the backup before removing it. See
“Taking the T1600 Host Subsystem Offline” on page 365
.
To remove a Routing Engine ( “Reinstalling the Routing Engine Cover” on page 377
and
1.
Take the host subsystem offline as described in
“Taking the T1600 Host Subsystem
.
2.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
Loosen the captive screws on the corners of the Routing Engine cover.
5.
Grasp the Routing Engine cover by its edges and pull it free from the chassis (see
6.
If applicable, loosen the screws on the extractor handles at either end of the Routing
Engine faceplate, using a Phillips screwdriver.
7.
Press the red tabs on the ejector handles on both sides of the Routing Engine faceplate.
374 Copyright © 2019, Juniper Networks, Inc.
Chapter 28: Replacing Host Subsystem Components
8.
Flip the ejector handles outward to unseat the Routing Engine.
9.
Grasp the Routing Engine by the ejector handles and slide it about halfway out of the chassis.
10.
Place one of your hands underneath the Routing Engine to support it and slide it completely out of the chassis.
11.
Place the Routing Engine on the antistatic mat.
12.
If you are not replacing the Routing Engine now, reinstall the Routing Engine cover and tighten the screws on the corners of the cover to secure it to the chassis (see
“Reinstalling the Routing Engine Cover” on page 377 ).
Figure 173: Removing the Routing Engine Cover
Figure 174: Removing a Routing Engine
Copyright © 2019, Juniper Networks, Inc.
375
T1600 Core Router Hardware Guide
Figure 175: Removing a C1800 Routing Engine
See Also •
Maintaining the T1600 Routing Engines on page 521
•
T1600 Routing Engine Description on page 44
•
T1600 Routing Engine Interface Cable and Wire Specifications on page 169
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Installing the T1600 Routing Engine
To install a Routing Engine (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Ensure that the ejector handles are not in the locked position. If necessary, press the red tabs and flip the ejector handles outward.
3.
Place one hand underneath the Routing Engine to support it. With the other hand, grasp one of the ejector handles on the faceplate.
4.
Carefully align the sides of the Routing Engine with the guides inside the chassis.
5.
Slide the Routing Engine into the chassis until you feel resistance, then press the
Routing Engine's faceplate until it engages the midplane connectors.
6.
Press both the ejector handles inward to seat the Routing Engine.
The Routing Engine might require several minutes to boot.
376 Copyright © 2019, Juniper Networks, Inc.
Chapter 28: Replacing Host Subsystem Components
7.
If applicable, tighten the screws on the extractor handles, using a Phillips screwdriver.
Be sure to tighten the screws enough to seat the Routing Engine properly.
8.
Press the Routing Engine cover into place, then tighten the captive screws on the corners of the cover to secure it to the chassis (see
).
Figure 176: Installing a Routing Engine
Figure 177: Reinstalling the Routing Engine Cover
See Also •
Maintaining the T1600 Routing Engines on page 521
•
T1600 Routing Engine Description on page 44
•
T1600 Routing Engine Interface Cable and Wire Specifications on page 169
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Copyright © 2019, Juniper Networks, Inc.
377
T1600 Core Router Hardware Guide
Verifying the Installation of the T1600 Routing Engine
If the router is powered on and the Routing Engine's corresponding control board is functioning normally, the Routing Engine comes online automatically. To verify that the
Routing Engine is functioning normally:
1.
Check the HOST0 and HOST1 LEDs on the craft interface.
• The green OK LED should light steadily a few minutes after the Routing Engine is installed.
• If the red FAIL LED is lit steadily, remove and install the Routing Engine again (see
“Removing a T1600 Routing Engine” on page 374
and
). Make sure that the Routing Engine is seated properly. If the
FAIL LED still lights steadily, the Routing Engine is not functioning properly. Contact your customer support representative.
2.
Verify that the Routing Engine is functioning properly. Display the status of the Routing
Engine by issuing the show chassis routing-engine command: user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
Temperature 32 degrees C / 89 degrees F
CPU temperature 33 degrees C / 91 degrees F
DRAM 2048 MB
Memory utilization 8 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 2 percent
Interrupt 0 percent
Idle 98 percent
Model RE-4.0
Serial ID P13004101110
Start time 2007-04-30 08:38:22 PDT
Uptime 2 days, 2 hours, 22 minutes, 43 seconds
Load averages: 1 minute 5 minute 15 minute
0.02 0.02 0.00
For more information about using the CLI, see the Junos OS manuals.
See Also •
Maintaining the T1600 Routing Engines on page 521
•
T1600 Routing Engine Description on page 44
•
T1600 Routing Engine Interface Cable and Wire Specifications on page 169
Related
Documentation
•
Maintaining the T1600 Routing Engines on page 521
•
T1600 Routing Engine Description on page 44
378 Copyright © 2019, Juniper Networks, Inc.
Chapter 28: Replacing Host Subsystem Components
•
T1600 Routing Engine Interface Cable and Wire Specifications on page 169
Replacing a CompactFlash Card in a T1600 RE-C1800 Routing Engine
1.
Preparing to Replace a CompactFlash Card in a T1600 C1800 Routing
2.
Removing a CompactFlash Card in a T1600 C1800 Routing Engine on page 381
3.
Installing a CompactFlash Card in a T1600 C1800 Routing Engine on page 382
4.
Copying Junos OS to the CompactFlash Card in a T1600 C1800 Routing
Preparing to Replace a CompactFlash Card in a T1600 C1800 Routing Engine
To prepare to replace a CompactFlash card in a T1600 RE-C1800:
1.
Determine whether the host subsystem is functioning as the master or as the backup, using one of these methods:
• For standalone T1600 routers:
• Check the Host Subsystem LEDs on the craft interface. If the green MASTER LED is lit, the corresponding host subsystem is functioning as the master.
• Check the MASTER LED on the control board. If the blue MASTER LED is lit, the host subsystem is functioning as the master.
• Issue the following command: user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
...
In this example, the Routing Engine in slot 0 is designated Master in the Current state field
• For T1600 routers in a routing matrix, verify that the master Routing Engine for all routers in the routing matrix are in the same slot.
To determine whether the host subsystems are functioning as the master or as the backup:
• Issue the show chassis routing-engine CLI command from the TX Matrix Plus router.
The master Routing Engine is designated Master in the Current state field. In this example, the Master Routing Engine is in Slot 0 for both sfc0-re0 and lcc0-re0 .
user@host> show chassis routing-engine
Copyright © 2019, Juniper Networks, Inc.
379
T1600 Core Router Hardware Guide
380 sfc0-re0:
--------------------------------------------------------------------------
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
Routing Engine status:
Slot 1:
Current state Backup
Election priority Backup (default)
...
lcc0-re0:
--------------------------------------------------------------------------
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
...
Routing Engine status:
Slot 1:
Current state Backup
Election priority Backup (default)
...
In this example, the Master Routing Engine is in Slot 0 for sfc0-re0 but Slot 1 for lcc0-re0 .
user@host> show chassis routing-engine sfc0-re0:
--------------------------------------------------------------------------
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
Routing Engine status:
Slot 1:
Current state Backup
Election priority Backup (default)
...
lcc0-re0:
--------------------------------------------------------------------------
Routing Engine status:
Slot 0:
Current state Backup
Election priority Master (default)
...
Routing Engine status:
Slot 1:
Current state Master
Election priority Backup (default)
...
If the master host subsystem for any T1600 router lcc in a routing matrix is in a different slot from the master host subsystem for the TX Matrix Plus router sfc , use the request chassis routing-engine master switch lcc command to correct the problem.
Copyright © 2019, Juniper Networks, Inc.
Chapter 28: Replacing Host Subsystem Components
NOTE: This command switches the master routing engine in the T1600 router.
user@host> request chassis routing-engine master switch lcc 0 warning: Traffic will be interrupted while the PFE is re-initialized
Toggle mastership between routing engines ? [yes,no] (no) yes
Resolving mastership...
Complete. The local routing engine becomes the master.
2.
If the host subsystem is functioning as the master, switch it to backup.
• For a standalone T1600 router, issue the request chassis routing-engine master switch command.
• For a T1600 router in a routing matrix, issue the request chassis routing-engine master switch all-chassis command from the TX Matrix Plus router.
3.
From the master Routing Engine, power down the backup Routing Engine.
• For a standalone T1600 router, issue the request system power-off other-routing-engine command.
• For a T1600 router in a routing matrix, issue the request system power-off lcc number other-routing-engine command from the TX Matrix Plus router.
Replace number with a value from 0 through 3 for the line-card chassis (lcc).
Removing a CompactFlash Card in a T1600 C1800 Routing Engine
The CompactFlash card is located in the slot labeled CF on the Routing Engine faceplate.
To remove the CompactFlash card:
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Verify that the Online , DISK1 , and CF LEDs on the backup Routing Engine faceplate are off.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
Using a Phillips (+) screwdriver, number 2, loosen the captive screws on the corners of the cover over the Routing Engine slots.
5.
Remove the cover from the Routing Engine slots.
CAUTION: Do not remove the cover if any of the LEDs are lit.
Copyright © 2019, Juniper Networks, Inc.
381
T1600 Core Router Hardware Guide
6.
Press the eject button on the right side of the CompactFlash card slot to release the
CompactFlash card.
7.
The CompactFlash card pops partially out of the slot. Grasp the card and pull it completely out of the slot.
8.
Place the CompactFlash card on the antistatic mat.
Figure 178: Removing a CompactFlash Card
Disk 2
Disk 1
CF
Disk 2
Disk 1
CF
D
S
I
CF
K
1
S
K
D
I
2
USB
Offline
Online
Installing a CompactFlash Card in a T1600 C1800 Routing Engine
To install a CompactFlash card:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Remove the cover from the Routing Engine slots by loosening the captive screws on the corners of the cover (using a Phillips (+) screwdriver, number 2).
3.
Insert the CompactFlash card into the CompactFlash card slot on the Routing Engine, with the logo facing up.
CAUTION: Be sure to insert the CompactFlash card with the label facing up. Inserting the CompactFlash card incorrectly might damage the Routing
Engine.
4.
Press the card firmly all the way into the slot.
5.
Reinstall the Routing Engine cover. Using a Phillips (+) screwdriver, number 2, tighten the screws on the corners of the cover to secure it to the Routing Engine.
6.
From the master Routing Engine, power on the Routing Engine.
• For a standalone T1600 router, issue the request system power-on other-routing-engine command.
• For a T1600 router in a routing matrix, issue the request system power-on lcc number other-routing-engine command from the TX Matrix Plus router.
382 Copyright © 2019, Juniper Networks, Inc.
Chapter 28: Replacing Host Subsystem Components
Replace number with a value from 0 through 3 for the line-card chassis (lcc).
NOTE: After you replace a CompactFlash card, the Routing Engine boots from the solid-state disk (SSD). You may get an error message and be prompted for a keystroke. After you press the keystroke, it might take up to 10 minutes for the Routing Engine to reset and for the router to boot from the SSD.
Figure 179: Installing a CompactFlash Card
Disk 2
Disk 1
CF
Disk 2
Disk 1
CF
S
K
D
I
CF 1
K
2
D
S
I
USB
Offline
Online
Reset
Copying Junos OS to the CompactFlash Card in a T1600 C1800 Routing Engine
After installing the CompactFlash card for the first time, you must copy the software from the Routing Engine's solid-state disk (SSD) to the CompactFlash card.
To copy software to the CompactFlash card:
1.
On the console or other management device connected to the Routing Engine, enter
CLI operational mode and copy the currently running and active file system partitions on the router to standby partitions on the CompactFlash card.
• On standalone T1600 routers, issue the request system snapshot partition command.
• On T1600 routers in a routing matrix, issue the request system snapshot partition lcc number command.
Replace number with a value from 0 through 3 for the line-card chassis (lcc).
2.
Wait until a message appears on the console confirming that the snapshot partition procedure is complete.
3.
Issue the request system reboot command to reboot the router's software.
4.
Issue the show system boot-messages command to verify that the CompactFlash card is listed as the primary boot device. The output lists the devices mounted. The
CompactFlash card is located at ad0 .
Related
Documentation
•
T1600 Routing Engine Description on page 44
•
T1600 RE-C1800 Description on page 49
•
T1600 RE-C1800 LEDs on page 51
Copyright © 2019, Juniper Networks, Inc.
383
T1600 Core Router Hardware Guide
•
T1600 Craft Interface Host Subsystem LEDs on page 36
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Replacing a DIMM Module in a T1600 Routing Engine
1.
Removing a T1600 DIMM Module on page 384
2.
Installing a T1600 DIMM Module on page 384
Removing a T1600 DIMM Module
The DIMM modules are located on the top of the Routing Engine. To remove a DIMM module:
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Remove the Routing Engine.
4.
Depending on which Routing Engine you are using, there are two different procedures for ejecting the DIMMs:
• For Routing Engines with an ejector on one side of the DIMM, press the plastic ejector of the DIMM module. The edge of the module raises upward.
• For Routing Engines with ejectors on each side of the DIMM, press the plastic ejectors on both sides of the DIMM module.
5.
Grasp the DIMM module, being careful not to touch any electrical components on the module, and firmly pull it out of the slot on the Routing Engine.
6.
Place the DIMM module on the antistatic mat or in the electrostatic bag.
7.
Push the plastic ejectors to close the empty DIMM module slot.
See Also •
T1600 Routing Engine Description on page 44
•
Removing a T1600 Routing Engine on page 374
Installing a T1600 DIMM Module
To insert a DIMM module into the Routing Engine:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Remove the DIMM module from its electrostatic bag.
3.
To open the empty DIMM slot, press the plastic ejectors open.
4.
Grasp the DIMM module by the edges, being careful not to touch any electrical components.
384 Copyright © 2019, Juniper Networks, Inc.
Chapter 28: Replacing Host Subsystem Components
5.
Pressing firmly on both ends, push the module into the slot until the ejectors return completely to the closed position.
6.
Install the Routing Engine.
7.
You can view the SDRAM configuration and verify the DIMM was installed correctly by issuing the show chassis routing-engine command.
user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
Temperature 32 degrees C / 89 degrees F
CPU temperature 33 degrees C / 91 degrees F
DRAM 2048 MB
Memory utilization 8 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 2 percent
Interrupt 0 percent
Idle 98 percent
Model RE-4.0
Serial ID P13004101110
Start time 2007-04-30 08:38:22 PDT
Uptime 2 days, 2 hours, 22 minutes, 43 seconds
Load averages: 1 minute 5 minute 15 minute
0.02 0.02 0.00
Figure 180: Installing the DIMM Module
See Also •
T1600 Routing Engine Description on page 44
•
Installing the T1600 Routing Engine on page 376
Copyright © 2019, Juniper Networks, Inc.
385
T1600 Core Router Hardware Guide
Related
Documentation
•
T1600 Routing Engine Description on page 44
•
Replacing a T1600 Routing Engine on page 374
Replacing a PC Card in a T1600 Routing Engine
1.
Removing a T1600 PC Card on page 386
2.
Installing the T1600 PC Card on page 387
Removing a T1600 PC Card
The PC Card is inserted into the slot labeled PC CARD on the Routing Engine. To remove the PC Card (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Remove the Routing Engine cover by loosening the captive screws on the corners of its faceplate.
4.
On the Routing Engine faceplate, press the eject button on the right side of the PC
Card slot once to release the button. Press again to release the PC Card.
NOTE: The Routing Engine in your router might have two PC Card slots.
In this case, use either slot. Do not install more than one PC Card in the
Routing Engine.
5.
The PC Card pops partially out of the slot. Grasp the card and pull it completely out of the slot.
6.
Place the PC Card on the antistatic mat.
7.
If you are not replacing the PC Card now, reinstall the Routing Engine cover and tighten the screws on the corners of the cover to secure it to the chassis.
386 Copyright © 2019, Juniper Networks, Inc.
Figure 181: Removing a PC Card
Chapter 28: Replacing Host Subsystem Components
See Also •
T1600 Chassis Description on page 21
•
T1600 Physical Specifications on page 139
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Installing the T1600 PC Card
To install a PC Card (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
If the Routing Engine cover is in place, remove the cover by loosening the captive screws on the corners of its faceplate.
3.
Insert the PC Card into the PC Card slot on the Routing Engine, with the Juniper
Networks logo facing downward.
CAUTION: Be sure to insert the PC Card with the label facing downward.
Inserting the PC Card incorrectly might damage the Routing Engine.
NOTE: The Routing Engine 1600 has two PC Card slots. In this case, use either slot. Do not install more than one PC Card in the Routing Engine.
Copyright © 2019, Juniper Networks, Inc.
387
T1600 Core Router Hardware Guide
4.
Press the card firmly all the way into the slot.
5.
Reinstall the Routing Engine cover and tighten the screws on the corners of the cover to secure it to the chassis.
Figure 182: Installing a PC Card
See Also •
T1600 Chassis Description on page 21
•
T1600 Physical Specifications on page 139
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Related
Documentation
•
T1600 Chassis Description on page 21
•
T1600 Physical Specifications on page 139
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Replacing a Solid-State Disk in a T1600 RE-C1800 Routing Engine
NOTE: For routers in a routing matrix, this procedure is supported for Junos
OS Release 11.4R3 and later, or Junos OS Release 12.1R2 and later.
1.
Preparing to Replace a Solid-State Disk in a T1600 RE-C1800 Routing
2.
Removing a Solid-State Disk in a T1600 RE-C1800 Routing Engine on page 391
388 Copyright © 2019, Juniper Networks, Inc.
Chapter 28: Replacing Host Subsystem Components
3.
Installing a Solid-State Disk in a T1600 RE-C1800 Routing Engine on page 392
4.
Copying Junos OS to the Solid-State Disk in a T1600 RE-C1800 Routing
Preparing to Replace a Solid-State Disk in a T1600 RE-C1800 Routing Engine
To prepare to replace a solid-state disk in a T1600 RE-C1800 Routing Engine:
1.
Determine whether the host subsystem is functioning as the master or as the backup, using one of these methods:
• For standalone T1600 routers:
• Check the host subsystem LEDs on the craft interface. If the green MASTER LED is lit, the corresponding host subsystem is functioning as the master.
• Check the MASTER LED on the control board. If the blue MASTER LED is lit, the host subsystem is functioning as the master.
• Issue the following command: user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
...
In this example, the Routing Engine in Slot 0 is designated Master in the Current state field.
• For T1600 routers in a routing matrix, verify that the master Routing Engines for all routers in the routing matrix are in the same slot.
To determine whether the host subsystems are functioning as the master or as the backup:
• Issue the show chassis routing-engine CLI command from the TX Matrix Plus router.
The master Routing Engine is designated Master in the Current state field. In this example, the Master Routing Engine is in Slot 0 for both sfc0-re0 and lcc0-re0 .
user@host> show chassis routing-engine sfc0-re0:
--------------------------------------------------------------------------
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
Routing Engine status:
Slot 1:
Current state Backup
Election priority Backup (default)
...
Copyright © 2019, Juniper Networks, Inc.
389
T1600 Core Router Hardware Guide
390 lcc0-re0:
--------------------------------------------------------------------------
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
...
Routing Engine status:
Slot 1:
Current state Backup
Election priority Backup (default)
...
In this example, the Master Routing Engine is in Slot 0 for sfc0-re0 but Slot 1 for lcc0-re0 .
user@host> show chassis routing-engine sfc0-re0:
--------------------------------------------------------------------------
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
Routing Engine status:
Slot 1:
Current state Backup
Election priority Backup (default)
...
lcc0-re0:
--------------------------------------------------------------------------
Routing Engine status:
Slot 0:
Current state Backup
Election priority Master (default)
...
Routing Engine status:
Slot 1:
Current state Master
Election priority Backup (default)
...
If the master host subsystem for any T1600 router lcc in a routing matrix is in a different slot from the master host subsystem for the TX Matrix Plus router sfc , use the request chassis routing-engine master switch lcc command to correct the problem.
NOTE: This command switches the master Routing Engine in the T1600 router.
user@host> request chassis routing-engine master switch lcc 0 warning: Traffic will be interrupted while the PFE is re-initialized
Toggle mastership between routing engines ? [yes,no] (no) yes
Copyright © 2019, Juniper Networks, Inc.
Chapter 28: Replacing Host Subsystem Components
Resolving mastership...
Complete. The local routing engine becomes the master.
2.
If the host subsystem is functioning as the master, switch it to backup.
• For a standalone T1600 router, issue the request chassis routing-engine master switch command.
• For a T1600 router in a routing matrix, issue the request chassis routing-engine master switch all-chassis command from the TX Matrix Plus router.
3.
From the master Routing Engine, power down the backup Routing Engine.
• For a standalone T1600 router, issue the request system power-off other-routing-engine command.
• For a T1600 router in a routing matrix, issue the request system power-off lcc number other-routing-engine command from the TX Matrix Plus router.
Replace number with a value from 0 through 3 for the line-card chassis (lcc).
Removing a Solid-State Disk in a T1600 RE-C1800 Routing Engine
The solid-state disk (SSD) is located in the slot labeled DISK1 on the Routing Engine faceplate.
NOTE: The DISK2 slot is not currently supported.
To remove an SSD from a Routing Engine:
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Verify that the Online , DISK1 , and CF LEDs on the backup Routing Engine faceplate are off.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
Using a Phillips (+) screwdriver, number 2, loosen the captive screws on the corners of the cover.
5.
Remove the cover from the Routing Engine slots.
CAUTION: Do not remove the cover if any of the LEDs on the Routing
Engine faceplate are lit.
6.
Press the eject button on the right side of the DISK1 slot to release the SSD.
Copyright © 2019, Juniper Networks, Inc.
391
T1600 Core Router Hardware Guide
7.
The SSD pops partially out of the slot. Grasp the SSD and carefully slide it completely out of the slot.
8.
Place the SSD on the antistatic mat.
Figure 183: Removing an SSD
Disk 2
Disk 1
CF
Disk 2
Disk 1
CF
CF
S
K
D
I
1
K
2
D
I
S
USB
Offline
Online
Installing a Solid-State Disk in a T1600 RE-C1800 Routing Engine
To install an SSD in a Routing Engine:
1.
Insert the SSD into the DISK1 slot on the Routing Engine, with the logo facing down.
CAUTION: Be sure to insert the SSD with the label facing down. Inserting the SSD incorrectly might damage the Routing Engine.
2.
Slide the SSD into the slot until you feel resistance, carefully ensuring that it is correctly aligned.
3.
Reinstall the Routing Engine cover. Using a Phillips (+) screwdriver, number 2, tighten the screws on the corners of the cover to secure it to the Routing Engine .
4.
From the master Routing Engine, power on the Routing Engine.
• For a standalone T1600 router, issue the request system power-on other-routing-engine command.
• For a T1600 router in a routing matrix, issue the request system power-on lcc number other-routing-engine command from the TX Matrix Plus router.
Replace number with a value from 0 through 3 for the line-card chassis (lcc).
Figure 184: Installing an SSD
Disk 2
Disk 1
CF
Disk 2
Disk 1
CF
CF
K
1
D
I
S
S
K
D
I
2
USB
Offline
Online
392 Copyright © 2019, Juniper Networks, Inc.
Chapter 28: Replacing Host Subsystem Components
Copying Junos OS to the Solid-State Disk in a T1600 RE-C1800 Routing Engine
After installing a solid-state disk (SSD) for the first time, you must copy the software from the Routing Engine's CompactFlash card to the SSD.
To copy software to the SSD:
1.
On the console or other management device connected to the Routing Engine, enter
CLI operational mode.
2.
Partition the SSD. See request system partition hard-disk .
• For standalone T1600 routers, issue the request system partition hard-disk command.
• For T1600 routers in a routing matix, issue the request system partition hard-disk lcc number command.
Replace number with a value from 0 through 3 for the line-card chassis (lcc).
3.
Wait until a message appears on the console confirming that the partition procedure is complete.
4.
Reboot the router's software.
• For standalone T1600 routers, issue the request system reboot command.
• For T1600 routers in a routing matrix, issue the request system reboot lcc number command.
Replace number with a value from 0 through 3 for the line-card chassis (lcc).
5.
Back up the currently running and active file system partitions on the router to standby partitions that are not running.
• For standalone T1600 routers, issue the request system snapshot command.
• For T1600 routers in a routing matrix, issue the request system snapshot lcc number command.
Replace number with a value from 0 through 3 for the line-card chassis (lcc).
6.
Wait until a message appears on the console confirming that the snapshot procedure is complete.
7.
Reboot the router's software again.
• For standalone T1600 routers, issue the request system reboot command.
• For T1600 routers in a routing matrix, issue the request system reboot lcc number command.
Replace number with a value from 0 through 3 for the line-card chassis (lcc).
8.
Verify that the SSD is listed as the secondary boot device. The output lists the devices mounted. The SSD is located at ad1 .
• For standalone T1600 routers, issue the show system boot-messages command.
Copyright © 2019, Juniper Networks, Inc.
393
T1600 Core Router Hardware Guide
• For T1600 routers in a routing matrix, issue the show system boot-messages lcc number command.
Replace number with a value from 0 through 3 for the line-card chassis (lcc).
Related
Documentation
•
T1600 Routing Engine Description on page 44
•
T1600 RE-C1800 Description on page 49
•
T1600 RE-C1800 LEDs on page 51
•
T1600 Craft Interface Host Subsystem LEDs on page 36
•
T1600 Preventing Electrostatic Discharge Damage on page 588
394 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 29
Replacing Line Card Components
•
Replacing a T1600 FPC on page 395
•
Replacing a T1600 PIC on page 402
•
Replacing a T1600 PIC Cable on page 408
Replacing a T1600 FPC
The FPCs are hot-insertable and hot-removable. When you remove an FPC, the router continues to function, although the PIC interfaces installed on the FPC being removed no longer function.
1.
Removing a T1600 FPC on page 395
2.
Installing a T1600 FPC on page 398
Removing a T1600 FPC
The router holds up to eight FPCs, which are installed vertically in the front of the router.
An empty FPC weighs approximately 25 lb (11.3 kg) and an FPC with PICs installed can weigh up to 37 lb (14.5 kg).
Each FPC slot not occupied by an FPC must be covered by an FPC blank panel. An FPC blank panel weighs 7 lb (3 kg).
To remove an FPC (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Use one of the following methods to take the FPC offline:
• Press and hold the FPC online/offline button. The green OK LED next to the button begins to blink. Hold the button down until the LED goes out. The LEDs and online/offline button for each FPC are located directly above it on the craft interface.
• Issue the following CLI command: user@host> request chassis fpc slot slot-number offline
Copyright © 2019, Juniper Networks, Inc.
395
T1600 Core Router Hardware Guide
For more information about the command, see request chassis fpc .
4.
Disconnect the cables from the PICs installed in the FPC. If a PIC uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap. Arrange the disconnected cables in the cable management system, to prevent the cables from developing stress points.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
5.
After you remove each PIC, immediately place it on an antistatic mat or in an electrostatic bag.
6.
If you are removing a Type 2 FPC or Type 3 FPC, loosen the screws inside the ejector handles at the top and bottom of the FPC faceplate.
7.
Simultaneously turn both the ejector handles counterclockwise to unseat the FPC.
8.
Grasp the handles and slide the FPC straight out of the card cage halfway.
9.
Place one hand around the front of the FPC (the PIC housing) and the other hand under it to support it. Slide the FPC completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.
CAUTION: The weight of the FPC is concentrated in the back end. Be prepared to accept the full weight—up to 37 lb (14.5 kg)—as you slide the
FPC out of the chassis.
When the FPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
396 Copyright © 2019, Juniper Networks, Inc.
Chapter 29: Replacing Line Card Components
Do not stack FPCs on top of one another after removal. Place each one individually in an electrostatic bag or on its own antistatic mat on a flat, stable surface.
10.
If you are not reinstalling an FPC into the emptied FPC slot within a short time, install a blank FPC panel over the slot to maintain proper airflow in the FPC card cage.
CAUTION: After removing an FPC from the chassis, wait at least 30 seconds before reinserting it, removing an FPC from a different slot, or inserting an FPC into a different slot.
Figure 185: Removing an FPC
T-1600 FPC4
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
Copyright © 2019, Juniper Networks, Inc.
397
T1600 Core Router Hardware Guide
•
Removing a T1600 PIC on page 403
•
Holding T1600 FPCs on page 515
•
Storing T1600 FPCs on page 520
•
Troubleshooting the T1600 FPCs on page 551
Installing a T1600 FPC
CAUTION: The FPC power connector is located in the corner where the bottom and the connector edges meet. If a power connector prong becomes bent, it no longer aligns with the female connector on the midplane, and the FPC no longer functions.
To install an FPC (see
and
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Place the FPC on an antistatic mat.
3.
Take each PIC to be installed in the replacement FPC out of its electrostatic bag and identify the slot on the FPC where it will be connected.
4.
Verify that each fiber-optic PIC has a rubber safety cap covering the PIC transceiver.
If it does not, cover the transceiver with a safety cap.
5.
Install each PIC into the appropriate slot on the FPC. For information about installing a PIC, see
“Installing a T1600 PIC” on page 405 .
6.
Locate the slot in the FPC card cage in which you plan to install the FPC.
7.
Inspect the slot in the FPC card cage to verify that there are no missing or bent pins on the midplane.
8.
Inspect the FPC to verify that the connectors are not misaligned or damaged.
9.
Orient the FPC vertically with the component side facing to the right. Be sure the FPC is right-side up, with the components on the right of the FPC.
CAUTION: When the FPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
398 Copyright © 2019, Juniper Networks, Inc.
Chapter 29: Replacing Line Card Components
10.
Carefully align the connector edge of the FPC with the appropriate empty slot in the chassis.
11.
Lift the FPC into place and carefully align the bottom and top of the FPC with the guides inside the card cage.
Figure 186: Installing an FPC
Do not bend or damage prongs on power connector
12.
Gently rest the bottom edge of the FPC on the bottom edge of the slot opening, making contact a short distance forward of the power connector.
CAUTION: Take care not to bend or otherwise damage the power connector prongs.
13.
Slowly slide the FPC into the slot until you feel resistance.
14.
Align the ejector handles on the FPC faceplate in a position close to horizontal.
Copyright © 2019, Juniper Networks, Inc.
399
T1600 Core Router Hardware Guide
15.
Simultaneously turn both ejector handles clockwise until you cannot turn them farther.
16.
If you are installing a Type 2 FPC or Type 3 FPC, tighten the screws inside the ejector handles to secure the FPC. Do not overtighten them.
17.
If any of the PICs on the FPC connect to fiber-optic cable, remove the rubber safety cap from each transceiver and cable.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
18.
Insert the appropriate cable into the cable connector ports on each PIC on the FPC.
Secure the cables so that they are not supporting their own weight. Place excess cable out of the way in a neatly coiled loop, using the cable management system. Placing fasteners on a loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
19.
Use one of the following methods to bring the FPC online:
• Press and hold the FPC online/offline button until the green OK LED next to the button lights steadily, in about 5 seconds. The LEDs and online/offline button for each FPC are located directly above it on the craft interface.
• Issue the following CLI command: user@host> request chassis fpc slot slot-number online
For more information about the command, see request chassis pic .
CAUTION: After the OK LED lights steadily, wait at least 30 seconds before removing the FPC again, removing an FPC from a different slot, or inserting an FPC in a different slot.
400 Copyright © 2019, Juniper Networks, Inc.
Chapter 29: Replacing Line Card Components
You can also verify correct FPC and PIC functioning by issuing the show chassis fpc and show chassis fpc pic-status commands, as described in
“Maintaining T1600 FPCs” on page 514
and
“Maintaining T1600 PICs and PIC Cables” on page 523
.
Figure 187: Installing an FPC
T-1600 FPC4
Copyright © 2019, Juniper Networks, Inc.
401
T1600 Core Router Hardware Guide
Figure 188: Connecting Fiber-Optic Cable to a PIC
See Also •
T1600 Flexible PIC Concentrator (FPC) Description on page 81
•
Holding T1600 FPCs on page 515
•
Storing T1600 FPCs on page 520
•
Troubleshooting the T1600 FPCs on page 551
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Related
Documentation
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 Flexible PIC Concentrator (FPC) Description on page 81
•
Holding T1600 FPCs on page 515
•
Storing T1600 FPCs on page 520
•
Troubleshooting the T1600 FPCs on page 551
Replacing a T1600 PIC
1.
Removing a T1600 PIC on page 403
2.
Installing a T1600 PIC on page 405
402 Copyright © 2019, Juniper Networks, Inc.
Chapter 29: Replacing Line Card Components
Removing a T1600 PIC
PICs are hot-insertable and hot-removable. When you remove a PIC, the router continues to function, although the PIC interfaces being removed no longer function.
The PICs are located in the FPCs installed in the front of the router. A PIC weighs less than 2 lb (0.9 kg).
To remove a PIC (see
):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface to receive the
PIC. If the PIC connects to fiber-optic cable, have ready a rubber safety cap for each transceiver and cable.
2.
Attach an electrostatic discharge ESD grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Use one of the following methods to take the PIC offline:
• Press and hold the online/offline button until the PIC LED goes out (about 5 seconds).
For a PIC installed in a Type 1 FPC, use a tool—such as a flat-blade screwdriver—to press the button slightly beneath the faceplate of the PIC. For a PIC installed in a
Type 2 FPC or Type 3 FPC, use a narrow-ended tool that fits inside the opening that leads to the button.
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot offline
For more information about the command, see request chassis pic .
4.
Label the cables connected to the PIC so that you can later reconnect each cable to the correct PIC.
5.
Disconnect the cables from the PIC. If the PIC uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
Copyright © 2019, Juniper Networks, Inc.
403
T1600 Core Router Hardware Guide
6.
Arrange the cable in the cable management system to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
7.
Unseat the PIC:
• Type 1 or Type 2 PIC—Loosen the captive screws at the top and bottom of the PIC faceplate.
• Type 3 PIC—Loosen the captive screw at the bottom of the PIC faceplate, then twist the ejector handle at the top of the faceplate and counterclockwise to unseat the
PIC.
• Type 4 PIC—Twist the ejector handle at the bottom of the PIC faceplate, then twist the ejector handle at the top of the faceplate and counterclockwise to unseat the
PIC.
8.
Slide the PIC out of the FPC card carrier, and place it in the electrostatic bag or on the antistatic mat.
9.
If you are not reinstalling a PIC into the emptied PIC slot within a short time, install a blank PIC panel over the slot to maintain proper airflow in the FPC card cage.
404 Copyright © 2019, Juniper Networks, Inc.
Figure 189: Removing a PIC
Chapter 29: Replacing Line Card Components
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Maintaining T1600 PICs and PIC Cables on page 523
•
T1600 PIC Description on page 94
•
Troubleshooting the T1600 PICs on page 555
Installing a T1600 PIC
To install a PIC (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
If the PIC uses fiber-optic cable, verify that there is a rubber safety cap over each transceiver on the faceplate. Install a cap if necessary.
3.
Align the notches in the connector at the rear of the PIC with the notches in the PIC slot in the FPC and then slide the PIC in until it lodges firmly in the FPC.
CAUTION: Slide the PIC straight into the slot to avoid damaging the components on the bottom of the PIC.
Copyright © 2019, Juniper Networks, Inc.
405
T1600 Core Router Hardware Guide
4.
Secure the PIC to the FPC faceplate:
• Type 1 or Type 2 PICs—Tighten the captive screws at the top and bottom of the faceplate.
• Type 3 PICs—Turn the ejector handle at the top of the PIC faceplate clockwise, then tighten the captive screw at the bottom of the faceplate.
• Type 4 PIC—Twist the ejector handle at the bottom of the PIC faceplate, then twist the ejector handle at the top of the faceplate and counterclockwise to unseat the
PIC.
5.
If the PIC uses fiber-optic cable, remove the rubber safety cap from each transceiver and the end of each cable.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
6.
Insert the appropriate cables into the cable connectors on the PIC.
7.
Arrange each cable in the cable management system to prevent the cable from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
8.
Use one of the following methods to bring the PIC online:
• Press the PIC offline/online button until the PIC LED lights green. For a PIC installed in a Type 1 FPC, use a tool—such as a flat-blade screwdriver—to press the button
406 Copyright © 2019, Juniper Networks, Inc.
Chapter 29: Replacing Line Card Components slightly beneath the faceplate of the PIC. For a PIC installed in a Type 2 FPC or Type
3 FPC, use a narrow-ended tool that fits inside the opening that leads to the button.
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
For more information about the command, see request chassis pic .
The normal functioning status LED confirms that the PIC is online. You can also verify correct PIC functioning by issuing the show chassis fpc pic-status command.
Figure 190: Installing a PIC
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Maintaining T1600 PICs and PIC Cables on page 523
•
T1600 PIC Description on page 94
•
Troubleshooting the T1600 PICs on page 555
Related
Documentation
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Maintaining T1600 PICs and PIC Cables on page 523
•
T1600 PIC Description on page 94
•
Troubleshooting the T1600 PICs on page 555
Copyright © 2019, Juniper Networks, Inc.
407
T1600 Core Router Hardware Guide
Replacing a T1600 PIC Cable
1.
Removing a T1600 PIC Cable on page 408
2.
Installing a T1600 PIC Cable on page 409
Removing a T1600 PIC Cable
Removing and installing PIC cables do not affect router function, except that a PIC does not receive or transmit data while its cable is disconnected. To remove a PIC cable:
1.
If the PIC connects to fiber-optic cable, have ready a rubber safety cap for each cable and transceiver.
2.
If removing all cables connected to the PIC, use one of the following methods to take the PIC offline:
• Press its online/offline button. For a Type 1 PIC, use a tool—such as a flat-blade screwdriver—to press the button slightly beneath the faceplate of the PIC. For a
Type 2 , Type 3, or Type 4 PIC, use a narrow-ended tool that fits inside the opening that leads to the button. Press and hold the button until the PIC LED goes out (about
5 seconds).
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot offline
For more information about the command, see request chassis pic .
3.
Unplug the cable from the cable connector port. If the PIC uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
4.
Remove the cable from the cable management system and detach it from the destination port.
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Maintaining T1600 PICs and PIC Cables on page 523
408 Copyright © 2019, Juniper Networks, Inc.
Chapter 29: Replacing Line Card Components
•
T1600 PIC Description on page 94
•
Connecting PIC Cables to the T1600 Router on page 242
Installing a T1600 PIC Cable
To install a PIC cable (see
1.
Have ready a length of the type of cable used by the PIC. For cable specifications, see the T1600 Core Router Interface Module Reference .
2.
If the PIC cable connector port is covered by a rubber safety plug, remove the plug.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
3.
Insert the cable connector into the cable connector port on the PIC faceplate.
4.
Arrange the cable in the cable management system, to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
5.
Insert the other end of the cable into the destination port.
Copyright © 2019, Juniper Networks, Inc.
409
T1600 Core Router Hardware Guide
6.
Repeat the previous steps for any additional cables.
7.
If the PIC is offline (its failure indicator LED is lit), use one of the following methods to bring the PIC online:
• Press the PIC offline/online button until the PIC LED lights green. For a Type 1 PIC, use a tool—such as a flat-blade screwdriver—to press the button slightly beneath the faceplate of the PIC. For a Type 2 , Type 3, or Type 4 PIC, use a narrow-ended tool that fits inside the opening that leads to the button.
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
For more information about the command, see request chassis pic ..
The normal functioning indicator LED confirms that the PIC is online. You can also verify correct PIC functioning by issuing the show chassis fpc pic-status command described in
“Maintaining T1600 PICs and PIC Cables” on page 523
.
Figure 191: Connecting Fiber-Optic Cable to a PIC
410
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 PIC Description on page 94
•
Connecting PIC Cables to the T1600 Router on page 242
Copyright © 2019, Juniper Networks, Inc.
Chapter 29: Replacing Line Card Components
Related
Documentation
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Maintaining T1600 PICs and PIC Cables on page 523
•
T1600 PIC Description on page 94
•
Connecting PIC Cables to the T1600 Router on page 242
Copyright © 2019, Juniper Networks, Inc.
411
T1600 Core Router Hardware Guide
412 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 30
Replacing Power System Components
•
Tools and Parts Required for Replacing T1600 DC Power System
•
Replacing a T1600 Three-Input 240-A DC Power Supply on page 414
•
Replacing a T1600 Four-Input 240-A DC Power Supply on page 425
•
•
Replacing a Front Air Filter on a T1600 AC or Three-Input 240-A or Four-Input 240-A
•
Replacing a T1600 Six-Input DC Power Supply on page 440
•
Replacing a T1600 DC Power Supply Cable on a Six-Input DC Power Supply on page 446
•
Replacing a T1600 Six-Input DC Power Supply Front Air Filter on page 449
•
Replacing a T1600 Six-Input DC Power Supply Side Air Filter on page 449
•
Replacing a T1600 Three-Phase Delta AC Power Supply on page 451
•
Replacing a T1600 Three-Phase Delta AC Power Supply Cord on page 459
•
Replacing a T1600 Three-Phase Wye AC Power Supply on page 465
•
Replacing a T1600 Three-Phase Wye AC Power Supply Cord on page 472
Tools and Parts Required for Replacing T1600 DC Power System Components
To replace a DC power supply, you need the following tools and equipment:
• Phillips (+) screwdriver, number 2
• ESD wrist strap with cable
• 7/16-in. (11 mm) nut driver
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
• Wire cutters
Copyright © 2019, Juniper Networks, Inc.
413
T1600 Core Router Hardware Guide
• Flashlight
• Flat-blade (–) screwdriver
Related
Documentation
•
Replacing a T1600 Three-Input 240-A DC Power Supply on page 414
•
Replacing a T1600 Four-Input 240-A DC Power Supply on page 425
•
Replacing a T1600 Six-Input DC Power Supply on page 440
•
T1600 DC Power Electrical Safety Guidelines on page 618
•
General Safety Guidelines for Juniper Networks Devices on page 585
Replacing a T1600 Three-Input 240-A DC Power Supply
The T1600 router has either one nonredundant power supply or two redundant, load-sharing power supplies. Each redundant power supply is hot-insertable and hot-removable. When a redundant power supply is powered down or removed, the other power supply automatically assumes the entire electrical load for the router. If you have only one power supply, you must power off the system before removing the power supply.
1.
Removing a T1600 Three-Input 240-A DC Power Supply on page 414
2.
Setting the Input Mode Switch on a T1600 Three-Input 240-A DC Power
3.
Installing a T1600 Three-Input 240-A DC Power Supply on page 419
4.
Replacing a Cable Restraint on the T1600 Three-Input 240-A DC Power
5.
Connecting a Replacement T1600 Three-Input 240-A DC Power Supply on page 422
6.
Powering On a Replacement T1600 Three-Input 240-A DC Power Supply on page 424
Removing a T1600 Three-Input 240-A DC Power Supply
To remove a three-input 240-A DC power supply:
1.
Switch off the external circuit breakers to the power supply being removed. Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during the removal process.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Switch the circuit breakers on the power supply faceplate to the off position ( O ).
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on.
414 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
4.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
5.
Using a 7/16-in. (11 mm) nut driver or wrench, remove the nuts and washers from the terminal studs (see
).
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
Figure 192: Disconnecting Power Cables from the DC Power Supply
6.
Remove the cable lugs from the terminal studs.
7.
Loosen the captive screw or screws on the cable restraint on the right edge of the power supply faceplate.
8.
Carefully move the power cables out of the way.
Copyright © 2019, Juniper Networks, Inc.
415
T1600 Core Router Hardware Guide
9.
Loosen the captive screws on the lower corners of the power supply faceplate completely.
10.
Twist the ejector handles on the upper corners of the faceplate counterclockwise to unseat the power supply.
11.
Grasp the handle on the power supply faceplate and pull firmly. Slide it halfway out of the chassis (see
CAUTION: Each three-input 240-A DC power supply weighs approximately
25 lb (11.3 kg). Be prepared to support the full weight of the power supply as you remove it from the router.
12.
Place one hand underneath the power supply to support it, and slide it completely out of the chassis.
WARNING: Do not touch the power connectors on the rear of the power supply (see
Figure 193 on page 416 ). They can contain dangerous voltages.
Figure 193: Rear of the Power Supply Showing Midplane Connectors
416
CAUTION: Do not leave a power supply slot empty for more than a short time while the router is operational. For proper airflow, the power supply must remain in the chassis or a blank panel must be used in an empty slot.
Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
Figure 194: Removing a Three-Input 240-A DC Power Supply
See Also •
Connecting a Replacement T1600 Three-Input 240-A DC Power Supply on page 422
•
Maintaining the T1600 Power Supplies on page 525
•
Powering On a Replacement T1600 Three-Input 240-A DC Power Supply on page 424
•
T1600 Three-Input 240-A DC Power Supply Specifications on page 146
Setting the Input Mode Switch on a T1600 Three-Input 240-A DC Power Supply
NOTE: Do not set the input mode switch if the power supply is installed in the chassis. If the power supply is already installed, you must remove it before setting the input mode switch.
NOTE: For the T1600 router, you must set the input-mode switch to 3-INPUT mode.
To set the input mode switch:
1.
Using a screwdriver, loosen the captive screw holding the metal cover over the input mode switch (see
).
2.
Rotate the metal cover away from the input mode switch to expose the switch.
3.
Check the setting of the input mode switch. Use a flashlight, if necessary. In 3-INPUT mode, the switch is located all the way to the left.
Copyright © 2019, Juniper Networks, Inc.
417
T1600 Core Router Hardware Guide
4.
Use a sharp, nonconductive object to slide the switch all the way to the left to set the power supply to 3-INPUT .
CAUTION: Do not use a pencil, because fragments can break off and cause damage to the power supply.
5.
Rotate the metal cover over the input mode switch, and use a screwdriver to tighten the captive screw.
shows the input mode switch.
Figure 195: Three-Input 240-ADC Power Supply
418
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Connecting a Replacement T1600 Three-Input 240-A DC Power Supply on page 422
•
Maintaining the T1600 Power Supplies on page 525
•
Powering On a Replacement T1600 Three-Input 240-A DC Power Supply on page 424
•
T1600 Three-Input 240-A DC Power Supply Specifications on page 146
Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
Installing a T1600 Three-Input 240-A DC Power Supply
Each three-input 240-A DC power supply weighs approximately 25 lb (11.3 kg). To install a three-input 240-A DC power supply:
1.
Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during installation.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Switch the circuit breakers on the power supply faceplate to the OFF position ( O ).
4.
Using both hands, slide the power supply into the chassis until you feel resistance
(see
5.
Twist the ejector handles at the upper corners of the power supply faceplate clockwise until they stop.
6.
Tighten the captive screws at the lower corners of the power supply faceplate to secure the power supply in the chassis.
Figure 196: Installing a Three-Input 240-ADC Power Supply
See Also •
Connecting a Replacement T1600 Three-Input 240-A DC Power Supply on page 422
•
Maintaining the T1600 Power Supplies on page 525
•
T1600 Preventing Electrostatic Discharge Damage on page 588 .
•
Powering On a Replacement T1600 Three-Input 240-A DC Power Supply on page 424
•
T1600 Three-Input 240-A DC Power Supply Specifications on page 146
Copyright © 2019, Juniper Networks, Inc.
419
T1600 Core Router Hardware Guide
Replacing a Cable Restraint on the T1600 Three-Input 240-A DC Power Supply
1.
Removing the Standard Cable Restraint from the T1600 Three-Input 240-A Power
2.
Installing the Optional Cable Restraint on the T1600 Three-Input 240-A DC Power
Removing the Standard Cable Restraint from the T1600 Three-Input 240-A Power
Supply
Each three-input 240-A power supply is shipped with the standard cable restraint, as shown in
. Two optional cable restraints are shipped in the accessory box for the T1600 router and in the T1600 upgrade kit.
If your DC power cables are too large or inflexible to fit into the standard cable restraint, we recommend that you remove the standard cable restraint and install the optional cable restraint (see
Figure 198 on page 421 ) on each three-input 240-A power supply.
NOTE: Before you remove a chassis from a rack or cabinet, you must remove the optional cable restraint from the three-input 240-A power supply.
The cable restraint is located on the right edge of the power supply faceplate. To remove the standard cable restraint:
1.
Loosen the captive screw on the standard cable restraint or captive screws on the optional cable restraint.
2.
Remove the cable restraint from the power supply.
Figure 197: Three-Input 240-A Power Supply with the Standard Cable Restraint
420 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
Figure 198: Three-Input 240-A Power Supply with the Optional Cable Restraint
See Also •
Connecting a Replacement T1600 Three-Input 240-A DC Power Supply on page 422
•
Maintaining the T1600 Power Supplies on page 525
•
T1600 Front Cable Management System Description on page 25
Installing the Optional Cable Restraint on the T1600 Three-Input 240-A DC Power
Supply
To install the optional cable restraint:
1.
Align the two captive screws on the optional cable restraint with the two threaded holes located at the right edge of the power supply faceplate.
2.
Fasten the captive screws.
See Also •
Connecting a Replacement T1600 Three-Input 240-A DC Power Supply on page 422
•
Maintaining the T1600 Power Supplies on page 525
•
T1600 Front Cable Management System Description on page 25
Related
Documentation
•
Connecting a Replacement T1600 Three-Input 240-A DC Power Supply on page 422
•
Maintaining the T1600 Power Supplies on page 525
•
T1600 Front Cable Management System Description on page 25
Copyright © 2019, Juniper Networks, Inc.
421
T1600 Core Router Hardware Guide
Connecting a Replacement T1600 Three-Input 240-A DC Power Supply
To connect a three-input 240-A DC power supply to the power sources:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Verify that a licensed electrician has attached cable lugs to the power cables that you supply.
3.
Verify that the voltage across the DC power source cables leads is 0 V and that there is no chance that the cables might become active during installation. If needed, switch off the customer site circuit breakers.
4.
Verify that the circuit breakers on the power supply faceplate are in the OFF position ( O ).
5.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
6.
Remove the nut and washer from each power terminal stud.
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
7.
Attach the lugs on the DC source power cables to the terminal studs.
a.
Attach the positive (+) DC source power cable lugs to the RETURN (return) terminals.
b.
Attach the negative (–) DC source power cable lugs to the –48V (input) terminals.
Secure the cable lugs to the terminal studs, first with a washer, then with a nut (see
Figure 199 on page 423 ). Use a 7/16-in. (11-mm) nut driver to tighten the nut. Apply
between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
422 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
NOTE: For power supplies set to 3-INPUT mode (required for the T1600 router), connect two DC power cables, one for RETURN and one for -48
V, to each of the three inputs.
8.
Loosen the captive screw or screws on the cable restraint on the right edge of the power supply faceplate.
9.
Route the DC power cables through the cable restraint.
10.
Tighten the cable restraint captive screw or screws to hold the power cables in place.
11.
Verify that the ground and power cabling are correct, that they are not touching or blocking access to other hardware components, and that they do not drape where people could trip on them.
12.
Replace the clear plastic cover over the terminal studs on the faceplate.
Figure 199: Connecting DC Power Cables to the Three-Input 240-A DC Power Supply
(PWR-T1600-3-80-DC-S)
Copyright © 2019, Juniper Networks, Inc.
423
T1600 Core Router Hardware Guide
See Also •
Installing a T1600 Three-Input 240-A DC Power Supply on page 419
•
T1600 Preventing Electrostatic Discharge Damage on page 588 .
•
T1600 Power System Description on page 113
•
Troubleshooting the T1600 Power System on page 552
Powering On a Replacement T1600 Three-Input 240-A DC Power Supply
To power on a replacement three-input 240-A power supply:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Switch on the customer site circuit breakers to provide voltage to the DC power source cables.
NOTE: If the system is completely powered off when you power on the power supply, the Routing Engine boots as the power supply completes its startup sequence. If the Routing Engine finishes booting, you must power off the system before you power on again. After powering off a power supply, wait at least 60 seconds before turning it back on.
3.
Verify that the INPUT PRESENT LEDs on the power supply faceplate are lit steadily, indicating that the inputs are receiving power.
4.
Switch the circuit breakers on the power supply to the ON position ( | ).
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the LEDs on the power supply, the command output displays, and messages on the LCD display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
5.
Verify that the CB ON LEDs on the power supply faceplate are lit steadily, indicating that the circuit breakers are on.
6.
Verify that the DC OK LED on the power supply faceplate is lit steadily, indicating that the power supply is correctly installed and is functioning properly. The DC OK LED blinks momentarily, then lights steadily.
See Also •
Installing a T1600 Three-Input 240-A DC Power Supply on page 419
•
T1600 Power System Description on page 113
424 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
•
T1600 Preventing Electrostatic Discharge Damage on page 588 .
•
Troubleshooting the T1600 Power System on page 552
•
T1600 General Electrical Safety Guidelines on page 613
Related
Documentation
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Connecting a Replacement T1600 Three-Input 240-A DC Power Supply on page 422
•
Maintaining the T1600 Power Supplies on page 525
•
Powering On a Replacement T1600 Three-Input 240-A DC Power Supply on page 424
•
T1600 Three-Input 240-A DC Power Supply Specifications on page 146
Replacing a T1600 Four-Input 240-A DC Power Supply
The T1600 router has either one nonredundant power supply or two redundant, load-sharing power supplies. Each redundant power supply is hot-insertable and hot-removable. When a redundant power supply is powered down or removed, the other power supply automatically assumes the entire electrical load for the router. If you have only one power supply, you must power off the system before removing the power supply.
1.
Removing a T1600 Four-Input 240-A DC Power Supply on page 425
2.
Installing a T1600 Four-Input 240-A Power Supply on page 429
Removing a T1600 Four-Input 240-A DC Power Supply
To remove a four-input 240-A DC power supply:
1.
Switch off the customer site circuit breakers to the power supply being removed. Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during the removal process.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Switch the circuit breakers on the power supply faceplate to the off position ( O ).
Copyright © 2019, Juniper Networks, Inc.
425
T1600 Core Router Hardware Guide
Figure 200: Four-Input 240-A DC Power Supply
LEDs Circuit breakers
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on.
4.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
5.
Using a 7/16-in. (11 mm) nut driver, remove the nuts and washers from the terminal studs (see
).
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
426 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
Figure 201: Disconnecting Power Cables from the Four-Input 240-A DC Power Supply
Cable lug Terminal studs
Locking washer
Nut
6.
Remove the cable lugs from the terminal studs.
7.
Loosen the captive screw or screws on the cable restraint on the right edge of the power supply faceplate.
8.
Carefully move the power cables out of the way.
9.
Loosen the captive screws on the lower corners of the power supply faceplate completely.
10.
Twist the ejector handles on the upper corners of the faceplate counterclockwise to unseat the power supply.
11.
Grasp the handle on the power supply faceplate and pull firmly. Slide it halfway out of the chassis (see
Copyright © 2019, Juniper Networks, Inc.
427
T1600 Core Router Hardware Guide
CAUTION: Each four-input 240-A DC power supply weighs approximately
26.6 lb (12.0 kg). Be prepared to support the full weight of the power supply as you remove it from the router.
12.
Place one hand underneath the power supply to support it and slide it completely out of the chassis.
Figure 202: Removing a Four-Input 240-A DC Power Supply
WARNING: Do not touch the power connectors on the rear of the power supply (see
). They can contain dangerous voltages.
Figure 203: Rear of the Power Supply Showing Midplane Connectors
428
See Also •
T1600 Power System Description on page 113
•
Maintaining the T1600 Power Supplies on page 525
Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 General Electrical Safety Guidelines on page 613
Installing a T1600 Four-Input 240-A Power Supply
Each four-input 240-A DC power supply weighs approximately 26.6 lb (12.0 kg). To install a four-input 240-A DC power supply:
1.
Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during installation.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Switch the circuit breakers on the power supply faceplate to the OFF position ( O ).
4.
Using both hands, slide the power supply into the chassis until you feel resistance
(see
).
5.
Twist the ejector handles at the upper corners of the power supply faceplate clockwise until they stop.
6.
Tighten the captive screws at the lower corners of the power supply faceplate to secure the power supply in the chassis.
7.
Verify that a licensed electrician has attached cable lugs to the power cables that you supply.
8.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
9.
Remove the nut and washer from each power terminal stud.
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
Copyright © 2019, Juniper Networks, Inc.
429
T1600 Core Router Hardware Guide
10.
Attach the lugs on the DC source power cables to the terminal studs.
a.
Attach the positive (+) DC source power cable lugs to the RETURN (return) terminals.
b.
Attach the negative (–) DC source power cable lugs to the –48V (input) terminals.
Secure the cable lugs to the terminal studs, first with a washer, then with a nut (see
Figure 204 on page 430 ). Use a 7/16-in. (11 mm) nut driver to tighten the nut. Apply
between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
Figure 204: Connecting a Power Cable to a Four-Input 240-A DC Power Supply
Cable lug Terminal studs
Locking washer
Nut
430
11.
Loosen the captive screws on the cable restraint on the right edge of the power supply faceplate.
12.
Route the DC power cables through the cable restraint.
Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
13.
Tighten the cable restraint captive screws to hold the power cables in place.
14.
Verify that the power cabling is correct, that the power cables do not touch or block access to other hardware components, and that they do not drape where people could trip on them.
15.
Replace the clear plastic cover over the terminal studs on the faceplate.
16.
Switch on the customer site circuit breakers to provide voltage to the DC power source cables.
17.
Verify that the INPUT PRESENT LEDs on the power supply faceplate are lit steadily, indicating that the inputs are receiving power.
18.
Switch the circuit breakers on the power supply to the ON position ( | ).
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the LEDs on the power supply, the command output displays, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
19.
Verify that the CB ON LEDs on the power supply faceplate are lit steadily, indicating that the circuit breakers are on.
20.
Verify that the DC OK LED on the power supply faceplate is lit steadily, indicating that the power supply is correctly installed and is functioning properly. The DC OK LED blinks momentarily, then lights steadily.
Figure 205: Installing a Four-Input 240-A DC Power Supply
Copyright © 2019, Juniper Networks, Inc.
431
T1600 Core Router Hardware Guide
See Also •
T1600 Power System Description on page 113
•
Maintaining the T1600 Power Supplies on page 525
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 General Electrical Safety Guidelines on page 613
Related
Documentation
•
T1600 Power System Description on page 113
•
Maintaining the T1600 Power Supplies on page 525
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 General Electrical Safety Guidelines on page 613
Replacing a T1600 DC Power Supply Cable on a Three-Input 240-A DC Power Supply or Four-Input 240-A DC Power Supply
1.
Removing a T1600 DC Power Supply Cable From a Three-Input 240-A DC Power
Supply or Four-Input 240-A DC Power Supply on page 432
2.
Removing a T1600 DC Power Supply Cable From a Three-Input 240-A DC Power Supply or
Four-Input 240-A DC Power Supply
You can use this procedure to remove a DC power cable from a three-input 240-A DC power supply or a four-input 240-A DC power supply. To remove a DC power supply cable:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Switch off the customer site circuit breakers for all the cables attached to the power supply. Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during the removal process.
3.
Remove the power cable from the external DC power source.
4.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
5.
Switch the circuit breakers on the power supply faceplate to the off position ( O ).
432 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
6.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
7.
Remove the nut and washer from the terminal stud on the power supply (see
). (Use a 7/16-in. (11 mm) nut driver.)
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
Figure 206: Disconnecting a Power Cable from a Three-Input 240-A DC Power Supply
Copyright © 2019, Juniper Networks, Inc.
433
T1600 Core Router Hardware Guide
Figure 207: Disconnecting a Power Cable from a Four-Input 240-A DC Power Supply
Cable lug Terminal studs
Locking washer
Nut
434
8.
Remove the cable lug from the terminal stud on the power supply.
9.
Loosen the captive screw or screws on the cable restraint on the right edge of the power supply faceplate.
10.
Carefully move the power cable out of the way.
See Also •
T1600 Power System Description on page 113
•
Maintaining the T1600 Power Supplies on page 525
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 General Electrical Safety Guidelines on page 613
Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
Installing a T1600 DC Power Supply Cable on a Three-Input 240-A DC Power Supply or
Four-Input 240-A DC Power Supply
You can use this procedure to install a DC power cable on either a three-input 240-A DC power supply or a four-input 240-A DC power supply. To install a DC power supply cable:
1.
Locate a DC power cable that meets the specifications defined in
.
CAUTION: A licensed electrician must attach a cable lug to the power cable that you supply. A cable with an incorrectly attached lug can damage the router.
2.
Route the power cable through the cable restraint.
3.
Attach the lug on the DC source power cable to the terminal stud.
a.
Attach a positive (+) DC source power cable lug to the RETURN (return) terminals.
b.
Attach a negative (–) DC source power cable lug to the –48V (input) terminals.
Secure the cable lug to the terminal stud, first with a washer, then with a nut (see
and
). Use a 7/16-in. (11-mm) nut driver to tighten the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
Copyright © 2019, Juniper Networks, Inc.
435
T1600 Core Router Hardware Guide
Figure 208: Connecting a Power Cable to a Three-Input 240-A DC Power Supply
436 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
Figure 209: Connecting a Power Cable to a Four-Input 240-A DC Power Supply
Cable lug Terminal studs
Locking washer
Nut
4.
Tighten the cable restraint captive screw or screws to hold the power cable in place.
5.
Replace the clear plastic cover over the terminal studs on the faceplate.
6.
Verify that the DC source power cabling is correct, that the power cable is not touching or blocking access to router components, and it does not drape where people could trip on it.
7.
Attach the other end of the power cable to the external DC power source.
8.
Switch on the customer site circuit breakers.
9.
Verify that the INPUT PRESENT LEDs on the power supply faceplate are lit steadily, indicating that the inputs are receiving voltage.
10.
Switch the circuit breakers on the power supply to the ON position ( | ).
Copyright © 2019, Juniper Networks, Inc.
437
T1600 Core Router Hardware Guide
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the LEDs on the power supply, the command output displays, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
11.
Verify that the CB ON LEDs on the power supply faceplate are lit steadily, indicating that the circuit breakers are on..
12.
Verify that the DC OK LED on the power supply faceplate is lit steadily, indicating that the power supply is correctly installed and is functioning properly. The DC OK LED blinks momentarily, then lights steadily.
See Also •
T1600 Power System Description on page 113
•
Maintaining the T1600 Power Supplies on page 525
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 General Electrical Safety Guidelines on page 613
Related
Documentation
•
T1600 Power System Description on page 113
•
Maintaining the T1600 Power Supplies on page 525
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 General Electrical Safety Guidelines on page 613
Replacing a Front Air Filter on a T1600 AC or Three-Input 240-A or Four-Input 240-A
DC Power Supply
You can use this procedure for a three-input 240-A DC power supply, four-input 240-A
DC power supply, three-phase delta AC power supply, or three-phase wye AC power supply.
1.
Removing a Front Air Filter on a T1600 AC or Three-Input 240-A or Four-Input 240-A
2.
Installing a Front Air Filter on a T1600 AC or Three-Input 240-A or Four-Input 240-A
438 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
Removing a Front Air Filter on a T1600 AC or Three-Input 240-A or Four-Input 240-A DC Power
Supply
To remove a power supply front air filter element (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the filter cover on the power supply faceplate and pull it straight off the power supply.
3.
Remove the front air filter element.
Figure 210: Removing a Front Air Filter Element
See Also •
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
Maintaining the T1600 Power Supplies on page 525
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
General Safety Guidelines for Juniper Networks Devices on page 585
• T1600 AC Power Electrical Safety Guidelines
Installing a Front Air Filter on a T1600 AC or Three-Input 240-A or Four-Input 240-A DC Power
Supply
To install a power supply front filter element (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
Copyright © 2019, Juniper Networks, Inc.
439
T1600 Core Router Hardware Guide
2.
Install a new filter element.
3.
Press the filter cover straight onto the power supply faceplate until all four sides click into place.
Figure 211: Installing a Front Air Filter Element
See Also •
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
Maintaining the T1600 Power Supplies on page 525
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
General Safety Guidelines for Juniper Networks Devices on page 585
• T1600 AC Power Electrical Safety Guidelines
Related
Documentation
•
Maintaining the T1600 Power Supplies on page 525
Replacing a T1600 Six-Input DC Power Supply
1.
Removing a T1600 Six-Input DC Power Supply on page 441
2.
Installing a T1600 Six-Input DC Power Supply on page 443
440 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
Removing a T1600 Six-Input DC Power Supply
To remove a six-input DC power supply:
1.
Switch off the customer site circuit breakers to the power supply being removed. Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during the removal process.
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on.
2.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
Figure 212: DC Power Supply
3.
Using a 7/16-in. (11 mm) nut driver, remove the nuts and washers from the terminal studs (see
).
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
Copyright © 2019, Juniper Networks, Inc.
441
T1600 Core Router Hardware Guide
Figure 213: Disconnecting Power Cables from the DC Power Supply
Cable lug
Terminal studs
Locking washer
Nut
4.
Remove the cable lugs from the terminal studs.
5.
Loosen the captive screws on the cable restraints on the right edge of the power supply faceplate.
6.
Carefully move the power cables out of the way.
7.
Loosen the captive screws on the lower corners of the power supply faceplate completely.
8.
Twist the ejector handles on the upper corners of the faceplate counterclockwise to unseat the power supply.
9.
Grasp the handle on the power supply faceplate, and pull firmly. Slide it halfway out of the chassis (see
).
CAUTION: Each DC power supply weighs approximately 39.7 lb (18.0 kg).
Be prepared to support the full weight of the power supply as you remove it from the router.
10.
Place one hand underneath the power supply to support it, and slide it completely out of the chassis.
442 Copyright © 2019, Juniper Networks, Inc.
Figure 214: Removing a DC Power Supply
Chapter 30: Replacing Power System Components
WARNING: Do not touch the power connectors on the rear of the power supply (see
Figure 215 on page 443 ). They can contain dangerous voltages.
Figure 215: Rear of the Power Supply Showing Midplane Connectors
Installing a T1600 Six-Input DC Power Supply
Each DC power supply weighs approximately 39.7 lb (18.0 kg). To install a six-input DC power supply:
1.
Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during installation.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
Copyright © 2019, Juniper Networks, Inc.
443
T1600 Core Router Hardware Guide
3.
Using both hands, slide the power supply into the chassis until you feel resistance
(see
Figure 216: Inserting the DC Power Supply into the Chassis
444
4.
Twist the ejector handles at the upper corners of the power supply faceplate clockwise until they stop.
5.
Tighten the captive screws at the lower corners of the power supply faceplate to secure the power supply in the chassis.
6.
Verify that a licensed electrician has attached cable lugs to the power cables that you supply.
7.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
8.
Remove the nut and washer from each power terminal stud.
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
9.
Attach the lugs on the DC source power cables to the terminal studs.
a.
Attach the negative (–) DC source power cable lug to the –48V (input) terminal.
b.
Attach the positive (+) DC source power cable lug to the RTN (return) terminal.
Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
Secure the cable lugs to the terminal studs, first with a washer, then with a nut (see
Figure 217 on page 445 ). Use a 7/16-in. (11 mm) nut driver to tighten the nut. Apply
between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
Figure 217: Attaching the DC Power Cable
Cable lug
Terminal studs
Locking washer
Nut
10.
Loosen the captive screws on the cable restraint on the right edge of the power supply faceplate.
11.
Route the DC power cables through the cable restraint.
12.
Tighten the cable restraint captive screws to hold the power cables in place.
13.
Verify that the power cabling is correct, that the power cables do not touch or block access to other hardware components, and that they do not drape where people could trip on them.
14.
Replace the clear plastic cover over the terminal studs on the faceplate.
15.
Switch on the customer site circuit breakers to provide voltage to the DC power source cables.
16.
Verify that the INPUT PRESENT LEDs on the power supply faceplate are lit steadily, indicating that the inputs are receiving power.
17.
Switch the power switch on the power supply to the ON position ( | ). The DC OK LED blinks momentarily, then lights steadily.
Copyright © 2019, Juniper Networks, Inc.
445
T1600 Core Router Hardware Guide
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the LEDs on the power supply, the command output displays, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
18.
Verify that the DC OK LED on the power supply faceplate is lit steadily, indicating that the power supply is correctly installed and is functioning properly.
Related
Documentation
•
T1600 Power System Description on page 113
•
Maintaining the T1600 Power Supplies on page 525
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 General Electrical Safety Guidelines on page 613
Replacing a T1600 DC Power Supply Cable on a Six-Input DC Power Supply
1.
Removing a T1600 DC Power Supply Cable From a Six-Input DC Power
2.
Installing a T1600 DC Power Supply Cable on a Six-Input DC Power Supply on page 447
Removing a T1600 DC Power Supply Cable From a Six-Input DC Power Supply
To remove a DC power supply cable from a six-input DC power supply:
1.
Switch off the customer site circuit breakers for all the cables attached to the power supply. Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during the removal process.
2.
Remove the power cable from the external DC power source.
3.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
4.
Remove the nut and washer from the terminal stud on the power supply (see
Figure 218 on page 447 ). Use a 7/16-in. (11 mm) nut driver.
446 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
Figure 218: Disconnecting the DC Power Cable
Cable lug
Terminal studs
Locking washer
Nut
5.
Remove the cable lug from the terminal stud on the power supply.
6.
Loosen the captive screw or screws on the cable restraint on the right edge of the power supply faceplate.
7.
Carefully move the power cable out of the way.
Installing a T1600 DC Power Supply Cable on a Six-Input DC Power Supply
To install a DC power supply cable on a six-input DC power supply:
1.
Locate a DC power cable that meets the specifications for the power supply.
CAUTION: A licensed electrician must attach a cable lug to the power cable that you supply. A cable with an incorrectly attached lug can damage the router.
2.
Route the power cable through the appropriate cable restraint.
3.
Attach the lug on the DC source power cable to the terminal stud.
a.
Attach a negative (–) DC source power cable lug to the –48V (input) terminals.
b.
Attach a positive (+) DC source power cable lug to the RET (return) terminals.
Secure the cable lug to the terminal stud, first with a washer, then with a nut (see
Figure 219 on page 448 ). Use a 7/16-in. (11-mm) nut driver to tighten the nut. Apply
between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut.
CAUTION: You must use an appropriate torque-controlled tool to tighten the nuts. Applying excessive torque damages the terminal studs and the power supply. The absolute maximum torque that may be applied to this nut is 45 lb-in. (5.0 Nm).
Copyright © 2019, Juniper Networks, Inc.
447
T1600 Core Router Hardware Guide
Figure 219: Connecting the DC Power Cable
Cable lug
Terminal studs
Locking washer
Nut
448
4.
Tighten the cable restraint captive screw or screws to hold the power cable in place.
5.
Replace the clear plastic cover over the terminal studs on the faceplate.
6.
Verify that the DC source power cabling is correct, that the power cable is not touching or blocking access to router components, and that it does not drape where people could trip on it.
7.
Attach the other end of the power cable to the external DC power source.
8.
Switch on the customer site circuit breakers.
9.
Verify that the INPUT PRESENT LEDs on the power supply faceplate are lit steadily, indicating that the inputs are receiving voltage.
10.
Switch the power switch on the power supply to the ON position ( | ). The DC OK LED blinks momentarily, then lights steadily.
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the LEDs on the power supply, the command output displays, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
11.
Verify that the DC OK LED on the power supply faceplate is lit steadily, indicating that the power supply is correctly installed and is functioning properly.
Related
Documentation
•
T1600 Power System Description on page 113
•
Maintaining the T1600 Power Supplies on page 525
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 General Electrical Safety Guidelines on page 613
Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
Replacing a T1600 Six-Input DC Power Supply Front Air Filter
1.
Removing a T1600 Six-Input DC Power Supply Front Air Filter on page 449
2.
Installing a T1600 Six-Input DC Power Supply Front Air Filter on page 449
Removing a T1600 Six-Input DC Power Supply Front Air Filter
To remove a six-input DC power supply :
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Grasp the filter cover on the power supply faceplate, and pull it straight off the power supply.
3.
Remove the air filter.
Installing a T1600 Six-Input DC Power Supply Front Air Filter
To install a six-input DC power supply front filter element:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Install a new filter element.
3.
Press the filter cover straight onto the power supply faceplate until all four sides click into place.
Related
Documentation
•
T1600 Cooling System Description on page 39
•
Routine Maintenance Procedures for the T1600 Router on page 507
•
Maintaining the T1600 Air Filters on page 510
•
Replacing a T1600 Six-Input DC Power Supply Side Air Filter on page 449
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Replacing a T1600 Six-Input DC Power Supply Side Air Filter
1.
Removing a T1600 Six-Input DC Power Supply Side Air Filter on page 450
2.
Installing a T1600 Six-Input DC Power Supply Side Air Filter on page 450
Copyright © 2019, Juniper Networks, Inc.
449
T1600 Core Router Hardware Guide
Removing a T1600 Six-Input DC Power Supply Side Air Filter
To remove a six-input DC power supply side air filter element:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Loosen the captive screw.
3.
Slide the air filter cover until the two lances leave the sheet metal.
4.
Remove the air filter cover hooks from the rectangle holes in the sheet metal.
5.
Remove the side air filter element from the air filter cover.
Figure 220: Removing the Power Supply Side Air Filter
Air filter cover
Air filter element
Installing a T1600 Six-Input DC Power Supply Side Air Filter
To install a six-input DC power supply side air filter element:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Install a new side filter element into the side air filter cover.
3.
Insert the side air filter cover hooks into the rectangle holes in the sheet metal.
450 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
4.
Slide the side air filter cover back into the power supply faceplate. The two lances insert into the sheet metal.
5.
Tighten the captive screw.
Figure 221: Installing the Power Supply Side Air Filter
Air filter element
Air filter cover
Related
Documentation
•
T1600 Cooling System Description on page 39
•
Routine Maintenance Procedures for the T1600 Router on page 507
•
Maintaining the T1600 Air Filters on page 510
•
Replacing a T1600 Six-Input DC Power Supply Front Air Filter on page 449
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Replacing a T1600 Three-Phase Delta AC Power Supply
The T1600 router has either one nonredundant power supply or two redundant, load-sharing power supplies. Each redundant power supply is hot-insertable and hot-removable. When a redundant power supply is powered down or removed, the other power supply automatically assumes the entire electrical load for the router. If you have only one power supply, you must power off the system before removing the power supply.
1.
Removing a T1600 Three-Phase Delta AC Power Supply on page 452
2.
Installing a T1600 Three-Phase Delta AC Power Supply on page 455
Copyright © 2019, Juniper Networks, Inc.
451
T1600 Core Router Hardware Guide
Removing a T1600 Three-Phase Delta AC Power Supply
To remove a three-phase delta AC power supply:
1.
Switch off the customer site circuit breakers to the power supply being removed. Make sure that the voltage across the AC power source cord is 0 V and that there is no chance that the cord might become active during the removal process.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Switch the power switch on the power supply faceplate to the standby position.
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on.
4.
Remove the ESD grounding strap from the ESD point on the chassis, and attach it to an approved site ESD grounding point. See the instructions for your site.
5.
Disconnect the AC power cord (see
) from the power source.
Figure 222: Three-Phase Delta AC Power Supply
452
6.
Remove the ESD grounding strap from the approved site ESD grounding point. See the instructions for your site. Reconnect the strap to one of the ESD points on the chassis.
7.
Using a number 2 Phillips (+) screwdriver, loosen the two screws on the door of the metal wiring compartment that protects the AC terminal block.
8.
Open the door of the metal wiring compartment.
Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
9.
Disconnect the wires from the AC terminal block on the three-phase delta AC power
supply ( Figure 223 on page 453
), loosen each of the input terminals or grounding point screws, and remove each wire from the grounding point or input terminal.
NOTE: The terminal connections have either slotted screws or hex screws.
Use a 1/4-in. slotted screwdriver for the slotted screws. Use a 5/32-in
(4-mm) Allen wrench for the 5/16-in hex screws.
a.
Remove the wire labeled L3 from the L3 input terminal.
b.
Remove the wire labeled L2 from the L2 input terminal.
c.
Remove the wire labeled L1 from the L1 input terminal.
d.
Remove the wire labeled GND from the grounding point labeled GND .
Figure 223: Disconnecting the Power Cord from a Three-Phase Delta AC Power Supply
L1 L2 L3
L1 L2 L3
10.
Loosen the plastic cable tie fastening the AC power cord to the power supply.
11.
Loosen and remove the retaining nut from the AC power cord.
Copyright © 2019, Juniper Networks, Inc.
453
T1600 Core Router Hardware Guide
12.
Pull the AC power cord out of the metal wiring compartment.
13.
Carefully move the AC power cable out of the way.
14.
Disconnect the AC power cord from the AC power supply.
15.
Loosen the captive screws on the lower corners of the power supply faceplate completely.
16.
Twist the ejector handles on the upper corners of the faceplate counterclockwise to unseat the power supply.
17.
Grasp the handle on the power supply faceplate and pull firmly. Slide it halfway out of the chassis (see
).
CAUTION: Each three-phase delta AC power supply weighs approximately
31.0 lb (14.06 kg). Be prepared to support the full weight of the power supply as you remove it from the router.
18.
Place one hand underneath the power supply to support it and slide it completely out of the chassis.
Figure 224: Removing a Three-Phase Delta AC Power Supply
454
WARNING: Do not touch the power connectors on the rear of the power supply (see
). They can contain dangerous voltages.
Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
Figure 225: Rear of the Power Supply Showing Midplane Connectors
See Also •
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
T1600 Three-Phase Delta and Wye AC Power Supply LEDs on page 124
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Installing a T1600 Three-Phase Delta AC Power Supply
Each three-phase delta AC power supply weighs approximately 31.0 lb (14.06 kg). To install a three-phase delta AC power supply:
1.
Make sure that the voltage across the AC power source cord leads is 0 V and that there is no chance that the cord might become active during installation.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Switch the power switch on the power supply faceplate to the standby position.
4.
Using both hands, slide the power supply into the chassis until you feel resistance
(see
).
5.
Twist the ejector handles at the upper corners of the power supply faceplate clockwise until they stop.
6.
Tighten the captive screws at the lower corners of the power supply faceplate to secure the power supply in the chassis.
Copyright © 2019, Juniper Networks, Inc.
455
T1600 Core Router Hardware Guide
7.
Using a number 2 Phillips (+) screwdriver, loosen the two screws on the door of the metal wiring compartment that protects the AC terminal block.
8.
Open the door of the metal wiring compartment.
9.
Unscrew the retaining nut from the AC power cord.
10.
Place the retaining nut inside the metal wiring compartment.
11.
Put the wires of the AC power cord through the hole of the metal wiring compartment.
12.
Screw the retaining nut onto the AC power cord to secure it to the metal wiring compartment.
456 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
13.
Connect the wires to the AC terminal block on the three-phase delta AC power supply
(
Figure 226 on page 457 ). Loosen each of the input terminal or grounding point screws,
insert the wire into the grounding point or input terminal, and tighten the screw.
NOTE: The terminal connections have either slotted screws or hex screws.
Use a 1/4-in. slotted screwdriver for the slotted screws. Use a 5/32-in
(4-mm) Allen wrench for the 5/16-in hex screws.
a.
Insert the wire labeled GND into the grounding point labeled GND .
b.
Insert the wire labeled L1 into the L1 input terminal c.
Insert the wire labeled L2 into the L2 input terminal.
d.
Insert the wire labeled LC3 into the LC3 input terminal.
Figure 226: Connecting Power to a Three-Phase Delta AC Power Supply
L1 L2 L3
L1 L2 L3
14.
Verify that the power cord wire connections are correct.
15.
Using a number 2 Phillips (+) screwdriver, tighten the two captive screws on the metal
AC wiring compartment.
Copyright © 2019, Juniper Networks, Inc.
457
T1600 Core Router Hardware Guide
16.
Verify that the AC power cord is not touching or blocking access to router components, and that it does not drape where people could trip on it.
17.
Remove the ESD grounding strap from the ESD points on the chassis. Connect the strap to an approved site ESD grounding point. See the instructions for your site.
18.
Connect the AC power cord plug to the power source.
19.
Switch on the customer site circuit breakers to provide voltage to the AC power cord.
20.
Remove the ESD grounding strap from the approved site ESD grounding point. See the instructions for your site. Reconnect the strap to one of the ESD points on the chassis.
21.
Verify that the AC OK LED on the power supply faceplate is lit steadily, indicating that the AC terminal block is receiving power.
22.
Switch the power switch on the power supply to the ON position ( | ) to provide power to the router components.
23.
Verify that the DC OK LED on the power supply faceplate is lit steadily, indicating that the power supply is correctly installed and is functioning properly. The DC OK LED blinks momentarily, then lights steadily.
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the LEDs on the power supply, the command output displays, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
458 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
Figure 227: Installing a Three-Phase Delta AC Power Supply
See Also •
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
T1600 Three-Phase Delta and Wye AC Power Supply LEDs on page 124
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Related
Documentation
•
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
T1600 Three-Phase Delta and Wye AC Power Supply LEDs on page 124
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Replacing a T1600 Three-Phase Delta AC Power Supply Cord
The T1600 router has either one nonredundant power supply or two redundant, load-sharing power supplies. An AC power supply cord on a redundant power supply is hot-insertable and hot-removable. When a redundant power supply is powered down, the other power supply automatically assumes the entire electrical load for the router.
If you have only one power supply, you must power off the system before removing the
AC power supply cord.
1.
Removing a T1600 Three-Phase Delta AC Power Supply Cord on page 460
2.
Installing a T1600 Three-Phase Delta AC Power Supply Cord on page 462
Copyright © 2019, Juniper Networks, Inc.
459
T1600 Core Router Hardware Guide
Removing a T1600 Three-Phase Delta AC Power Supply Cord
To remove a three-phase delta AC power supply cord:
1.
Switch off the customer site circuit breakers to the power supply being removed. Make sure that the voltage across the AC power source cord is 0 V and that there is no chance that the cord might become active during the removal process.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Switch the power switch on the power supply faceplate to the standby position.
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on.
4.
Remove the ESD grounding strap from the ESD point on the chassis, and attach it to an approved site ESD grounding point. See the instructions for your site.
5.
Disconnect the AC power cord (see
from the power source.
Figure 228: Three-Phase Delta AC Power Supply
460
6.
Remove the ESD grounding strap from the approved site ESD grounding point. See the instructions for your site. Reconnect the strap to one of the ESD points on the chassis.
7.
Using a number 2 Phillips (+) screwdriver, loosen the two screws on the door of the metal wiring compartment that protects the AC terminal block.
8.
Open the door of the metal wiring compartment.
Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
9.
Disconnect the wires from the AC terminal block on the three-phase delta AC power supply (
). Loosen each of the input terminals or grounding point screws, and remove each wire from the grounding point or input terminal.
NOTE: The terminal connections have either slotted screws or hex screws.
Use a 1/4-in. slotted screwdriver for the slotted screws. Use a 5/32-in
(4-mm) Allen wrench for the 5/16-in hex screws.
a.
Remove the wire labeled L3 from the L3 input terminal.
b.
Remove the wire labeled L2 from the L2 input terminal.
c.
Remove the wire labeled L1 from the L1 input terminal.
d.
Remove the wire labeled GND from the grounding point labeled GND .
Figure 229: Disconnecting the Power Cord from a Three-Phase Delta AC Power Supply
L1 L2 L3
L1 L2 L3
10.
Loosen the plastic cable tie fastening the AC power cord to the power supply.
11.
Loosen and remove the retaining nut from the AC power cord.
Copyright © 2019, Juniper Networks, Inc.
461
T1600 Core Router Hardware Guide
12.
Pull the AC power cord out of the metal wiring compartment.
13.
Carefully move the AC power cable out of the way.
14.
Disconnect the AC power cord from the AC power supply.
See Also •
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
T1600 Three-Phase Delta and Wye AC Power Supply LEDs on page 124
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Installing a T1600 Three-Phase Delta AC Power Supply Cord
To install a three-phase delta AC power supply cord:
1.
Make sure that the voltage across the AC power source cord leads is 0 V and that there is no chance that the cord might become active during installation.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Switch the power switch on the power supply faceplate to the standby position.
4.
Using a number 2 Phillips (+) screwdriver, loosen the two screws on the door of the metal wiring compartment that protects the AC terminal block.
5.
Open the door of the metal wiring compartment.
6.
Unscrew the retaining nut from the AC power cord.
7.
Place the retaining nut inside the metal wiring compartment.
8.
Put the wires of the AC power cord through the hole of the metal wiring compartment.
9.
Screw the retaining nut onto the AC power cord to secure it to the metal wiring compartment.
462 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
10.
Insert the wires to the AC terminal block on the three-phase delta AC power supply
(
Figure 230 on page 464 ). Loosen each of the input terminal or grounding point screws,
and insert the wire into the grounding point or input terminal.
NOTE: The terminal connections have either slotted screws or hex screws.
Use a 1/4-in. slotted screwdriver for the slotted screws. Use a 5/32-in
(4-mm) Allen wrench for the 5/16-in hex screws.
a.
Insert the wire labeled GND into the grounding point labeled GND .
b.
Insert the wire labeled L1 into the L1 input terminal c.
Insert the wire labeled L2 into the L2 input terminal.
d.
Insert the wire labeled LC3 into the LC3 input terminal.
11.
Verify that the power cord wire connections are correct.
12.
Using a number 2 Phillips (+) screwdriver, tighten the two captive screws on the metal
AC wiring compartment.
13.
Verify that the AC power cord is not touching or blocking access to router components, and that it does not drape where people could trip on it.
14.
Remove the ESD grounding strap from the ESD points on the chassis. Connect the strap to an approved site ESD grounding point. See the instructions for your site.
15.
Connect the AC power cord plug to the power source.
16.
Switch on the customer site circuit breakers to provide voltage to the AC power cord.
17.
Remove the ESD grounding strap from the approved site ESD grounding point. See the instructions for your site. Reconnect the strap to one of the ESD points on the chassis.
18.
Verify that the AC OK LED on the power supply faceplate is lit steadily, indicating that the AC terminal block is receiving power.
Copyright © 2019, Juniper Networks, Inc.
463
T1600 Core Router Hardware Guide
19.
Switch the power switch on the power supply to the ON position ( | ) to provide power to the router components.
20.
Verify that the DC OK LED on the power supply faceplate is lit steadily, indicating that the power supply is correctly installed and is functioning properly. The DC OK LED blinks momentarily, then lights steadily.
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the LEDs on the power supply, the command output displays, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
Figure 230: Connecting Power to a Three-Phase Delta AC Power Supply
L1 L2 L3
L1 L2 L3
464
See Also •
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
T1600 Three-Phase Delta and Wye AC Power Supply LEDs on page 124
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 AC Power Cord Specifications on page 159
Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
Related
Documentation
•
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
T1600 Three-Phase Delta and Wye AC Power Supply LEDs on page 124
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 AC Power Cord Specifications on page 159
Replacing a T1600 Three-Phase Wye AC Power Supply
The T1600 router has either one nonredundant power supply or two redundant, load-sharing power supplies. Each redundant power supply is hot-insertable and hot-removable. When a redundant power supply is powered down or removed, the other power supply automatically assumes the entire electrical load for the router. If you have only one power supply, you must power off the system before removing the power supply.
1.
Removing a T1600 Three-Phase Wye AC Power Supply on page 465
2.
Installing a T1600 Three-Phase Wye AC Power Supply on page 468
Removing a T1600 Three-Phase Wye AC Power Supply
To remove a three-phase wye AC power supply:
1.
Switch off the customer site circuit breakers to the power supply being removed. Make sure that the voltage across the AC power source cord is 0 V and that there is no chance that the power cord might become active during the removal process.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Switch the power switch on the power supply faceplate to the standby position.
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on.
4.
Remove the ESD grounding strap from the ESD point on the chassis, and attach it to an approved site ESD grounding point. See the instructions for your site.
5.
Disconnect the AC power cord (see
Figure 231 on page 466 ) from the power source.
Copyright © 2019, Juniper Networks, Inc.
465
T1600 Core Router Hardware Guide
Figure 231: Three-Phase Wye AC Power Supply
6.
Remove the ESD grounding strap from the approved site ESD grounding point. See the instructions for your site. Reconnect the strap to one of the ESD points on the chassis.
7.
Using a number 2 Phillips (+) screwdriver, unscrew the two screws on the metal cover protecting the AC terminal block.
466 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
8.
Disconnect the wires from the AC terminal block and grounding point on the three-phase wye AC power supply (
), loosen each screw, and remove each wire from the grounding point or input terminal.
NOTE: The terminal connections have either slotted screws or hex screws.
Use a 1/4-in. slotted screwdriver for the slotted screws. Use a 5/32-in
(4-mm) Allen wrench for the 5/16-in hex screws.
a.
Remove the wire labeled N from the N input terminal b.
Remove the wire labeled L3 from the L3 input terminal.
c.
Remove the wire labeled L2 from the L2 input terminal.
d.
Remove the wire labeled L1 from the L1 input terminal.
e.
Remove the wire labeled GND from the grounding point labeled GND .
Figure 232: Disconnecting the AC Power Cord from a Three-Phase Wye AC Power Supply
L1 L2 L3 N
9.
Loosen the plastic cable tie fastening the AC power cord to the power supply.
10.
Loosen and remove the retaining nut from the AC power cord.
11.
Pull the AC power cord out of the metal wiring compartment.
12.
Carefully move the AC power cable out of the way.
13.
Loosen the captive screws on the lower corners of the power supply faceplate completely.
14.
Twist the ejector handles on the upper corners of the faceplate counterclockwise to unseat the power supply.
Copyright © 2019, Juniper Networks, Inc.
467
T1600 Core Router Hardware Guide
15.
Grasp the handle on the power supply faceplate and pull firmly. Slide it halfway out of the chassis (see
CAUTION: Each three-phase wye AC power supply weighs approximately
31.0 lb (14.06 kg). Be prepared to support the full weight of the power supply as you remove it from the router.
16.
Place one hand underneath the power supply to support it and slide it completely out of the chassis.
Figure 233: Removing a Three-Phase Wye AC Power Supply
See Also •
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
T1600 Three-Phase Delta and Wye AC Power Supply LEDs on page 124
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 AC Power Cord Specifications on page 159
Installing a T1600 Three-Phase Wye AC Power Supply
Each three-phase wye AC power supply weighs approximately 31.0 lb (14.06 kg). To install a three-phase wye AC power supply:
1.
Make sure that the voltage across the AC power cord leads is 0 V and that there is no chance that the power cord might become active during installation.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
468 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
3.
Switch the power switch on the power supply faceplate to the standby position.
4.
Using both hands, slide the power supply into the chassis until you feel resistance
(see
5.
Twist the ejector handles at the upper corners of the power supply faceplate clockwise until they stop.
6.
Tighten the captive screws at the lower corners of the power supply faceplate to secure the power supply in the chassis.
7.
Using a slotted screwdriver, loosen the two screws securing the door of the metal wiring compartment.
8.
Open the door of the metal wiring compartment.
9.
Place the retaining screw into the metal wiring compartment.
10.
Unscrew the retaining nut from the AC power cord.
11.
Place the retaining nut inside the metal wiring compartment.
12.
Put the wires of the AC power cord through the hole of the metal wiring compartment.
13.
Screw the retaining nut onto the AC power cord to secure it to the metal wiring compartment.
Copyright © 2019, Juniper Networks, Inc.
469
T1600 Core Router Hardware Guide
14.
Connect the AC power cord wires to ground and the AC terminal block on the three-phase wye AC power supply (
). Loosen each of the input terminals or grounding point screws, insert each wire into the grounding point or input terminal, and tighten the screw.
NOTE: The terminal connections have either slotted screws or hex screws.
Use a 1/4-in. slotted screwdriver for the slotted screws. Use a 5/32-in
(4-mm) Allen wrench for the 5/16-in hex screws.
a.
Insert the wire labeled GND into the grounding point labeled GND .
b.
Insert the wire L1 into the L1 input terminal.
c.
Insert the wire labeled L2 into the L2 input terminal.
d.
Insert the wire labeled L3 into the L3 input terminal.
e.
Insert the wire labeled N into the N input terminal
Figure 234: Connecting Power to the Three–Phase Wye AC Power Supply
L1 L2 L3 N
470
15.
Verify that the power cord wire connections are correct.
16.
Using a number 2 Phillips (+) screwdriver, tighten the two captive screws on the metal
AC wiring compartment.
17.
Place the AC power cord into the plastic tie located on the right side of the power supply, and fasten the plastic tie.
18.
Verify that the AC power cord is not touching or blocking access to router components, and that it does not drape where people could trip on it.
19.
Remove the ESD grounding strap from the ESD points on the chassis. Connect the strap to an approved site ESD grounding point. See the instructions for your site.
Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
20.
Connect the AC power cord to the AC power source.
21.
Switch on the customer site circuit breakers to provide voltage to the AC power source cables.
22.
Remove the ESD grounding strap from the approved site ESD grounding point. See the instructions for your site. Reconnect the strap to one of the ESD points on the chassis.
23.
Verify that the AC OK LED on the power supply faceplate is lit steadily, indicating that the AC terminal block is receiving power.
24.
Switch the power switch on the power supply to the ON position ( | ).
25.
Verify that the DC OK LED on the power supply faceplate is lit steadily, indicating that the power supply is correctly installed and is functioning properly. The DC OK LED blinks momentarily, then lights steadily.
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the LEDs on the power supply, the command output displays, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
Figure 235: Installing a Three-Phase Wye AC Power Supply
See Also •
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
T1600 Three-Phase Delta and Wye AC Power Supply LEDs on page 124
Copyright © 2019, Juniper Networks, Inc.
471
T1600 Core Router Hardware Guide
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 AC Power Cord Specifications on page 159
Related
Documentation
•
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
T1600 Three-Phase Delta and Wye AC Power Supply LEDs on page 124
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 AC Power Cord Specifications on page 159
Replacing a T1600 Three-Phase Wye AC Power Supply Cord
The T1600 router has either one nonredundant power supply or two redundant, load-sharing power supplies. An AC power supply cord on a redundant power supply is hot-insertable and hot-removable. When a redundant power supply is powered down, the other power supply automatically assumes the entire electrical load for the router.
If you have only one power supply, you must power off the system before removing the
AC power supply cord.
1.
Removing a T1600 Three-Phase Wye AC Power Supply Cord on page 472
2.
Installing a T1600 Three-Phase Wye AC Power Supply Cord on page 475
Removing a T1600 Three-Phase Wye AC Power Supply Cord
To remove a three-phase wye AC power supply cord:
1.
Switch off the customer site circuit breakers to the power supply being removed. Make sure that the voltage across the AC power source cord is 0 V and that there is no chance that the power cord might become active during the removal process.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Switch the power switch on the power supply faceplate to the standby position.
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on.
4.
Remove the ESD grounding strap from the ESD point on the chassis, and attach it to an approved site ESD grounding point. See the instructions for your site.
5.
Disconnect the AC power cord (see
Figure 236 on page 473 ) from the power source.
472 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
Figure 236: Three-Phase Wye AC Power Supply
6.
Remove the ESD grounding strap from the approved site ESD grounding point. See the instructions for your site. Reconnect the strap to one of the ESD points on the chassis.
7.
Using a number 2 Phillips (+) screwdriver, unscrew the two screws on the metal cover protecting the AC terminal block.
Copyright © 2019, Juniper Networks, Inc.
473
T1600 Core Router Hardware Guide
8.
Disconnect the wires from the AC terminal block and grounding point on the three-phase wye AC power supply (
), loosen each screw, and remove each wire from the grounding point or input terminal.
NOTE: The terminal connections have either slotted screws or hex screws.
Use a 1/4-in. slotted screwdriver for the slotted screws. Use a 5/32-in
(4-mm) Allen wrench for the 5/16-in hex screws.
a.
Remove the wire labeled N from the N input terminal b.
Remove the wire labeled L3 from the L3 input terminal.
c.
Remove the wire labeled L2 from the L2 input terminal.
d.
Remove the wire labeled L1 from the L1 input terminal.
e.
Remove the wire labeled GND from the grounding point labeled GND .
Figure 237: Disconnecting the AC Power Cord from a Three-Phase Wye AC Power Supply
L1 L2 L3 N
474
9.
Loosen the plastic cable tie fastening the AC power cord to the power supply.
10.
Loosen and remove the retaining nut from the AC power cord.
11.
Pull the AC power cord out of the metal wiring compartment.
12.
Carefully move the AC power cable out of the way.
See Also •
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
T1600 Three-Phase Delta and Wye AC Power Supply LEDs on page 124
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
Installing a T1600 Three-Phase Wye AC Power Supply Cord
To install a three-phase wye AC power supply cord:
1.
Make sure that the voltage across the AC power cord leads is 0 V and that there is no chance that the power cord might become active during installation.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Switch the power switch on the power supply faceplate to the standby position.
4.
Using a slotted screwdriver, loosen the two screws securing the door of the metal wiring compartment.
5.
Open the door of the metal wiring compartment.
6.
Place the retaining screw into the metal wiring compartment.
7.
Unscrew the retaining nut from the AC power cord.
8.
Place the retaining nut inside the metal wiring compartment.
9.
Put the wires of the AC power cord through the hole of the metal wiring compartment.
10.
Screw the retaining nut onto the AC power cord to secure it to the metal wiring compartment.
Copyright © 2019, Juniper Networks, Inc.
475
T1600 Core Router Hardware Guide
11.
Connect the AC power cord wires to ground and the AC terminal block on the
three-phase wye AC power supply ( Figure 238 on page 476
). Loosen each of the input terminals or grounding point screws, insert each wire into the grounding point or input terminal, and tighten the screw.
NOTE: The terminal connections have either slotted screws or hex screws.
Use a 1/4-in. slotted screwdriver for the slotted screws. Use a 5/32-in
(4-mm) Allen wrench for the 5/16-in hex screws.
a.
Insert the wire labeled GND into the grounding point labeled GND .
b.
Insert the wire L1 into the L1 input terminal.
c.
Insert the wire labeled L2 into the L2 input terminal.
d.
Insert the wire labeled L3 into the L3 input terminal.
e.
Insert the wire labeled N into the N input terminal
Figure 238: Connecting Power to the Wye 3–Phase AC Power Supply
L1 L2 L3 N
476
12.
Verify that the power cord wire connections are correct.
13.
Using a number 2 Phillips (+) screwdriver, tighten the two captive screws on the metal
AC wiring compartment.
14.
Place the AC power cord into the plastic tie located on the right side of the power supply, and fasten the plastic tie.
15.
Verify that the AC power cord is not touching or blocking access to router components, and that it does not drape where people could trip on it.
16.
Remove the ESD grounding strap from the ESD points on the chassis. Connect the strap to an approved site ESD grounding point. See the instructions for your site.
Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Replacing Power System Components
17.
Connect the AC power cord to the AC power source.
18.
Switch on the customer site circuit breakers to provide voltage to the AC power source cables.
19.
Remove the ESD grounding strap from the approved site ESD grounding point. See the instructions for your site. Reconnect the strap to one of the ESD points on the chassis.
20.
Verify that the AC OK LED on the power supply faceplate is lit steadily, indicating that the AC terminal block is receiving power.
21.
Switch the power switch on the power supply to the ON position ( | ).
22.
Verify that the DC OK LED on the power supply faceplate is lit steadily, indicating that the power supply is correctly installed and is functioning properly. The DC OK LED blinks momentarily, then lights steadily.
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the LEDs on the power supply, the command output displays, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
See Also •
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
T1600 Three-Phase Delta and Wye AC Power Supply LEDs on page 124
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 AC Power Cord Specifications on page 159
Related
Documentation
•
T1600 Three-Phase Delta and Wye AC Power Supply Description on page 121
•
T1600 Three-Phase Delta and Wye AC Power Supply LEDs on page 124
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
T1600 AC Power Cord Specifications on page 159
Copyright © 2019, Juniper Networks, Inc.
477
T1600 Core Router Hardware Guide
478 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 31
Replacing Switch Fabric Components
•
Replacing a T1600-SIB on page 479
•
Replacing a TXP-T1600 SIB on page 482
•
Replacing a T1600 TXP-LCC-3D SIB on page 487
•
Replacing a T1600 SFP on page 493
•
Replacing a T1600 XFP on page 497
•
Replacing a T1600 XENPAK Module on page 499
Replacing a T1600-SIB
1.
Removing a T1600-SIB on page 479
2.
Installing a T1600-SIB on page 480
3.
Verifying the Installation of a T1600-SIB on page 482
Removing a T1600-SIB
Five SIBs are installed in the router. The SIBs are located in the rear of the chassis in the slots marked SIB0 through SIB4 . Each T1600-SIB weighs approximately 6.5 lb (3 kg).
To remove the SIBs (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Loosen the captive screws (using a Phillips (+) screwdriver, number 2) on the ejector handles on each side of the SIB faceplate.
4.
Flip the ejector handles outward to unseat the SIB.
Copyright © 2019, Juniper Networks, Inc.
479
T1600 Core Router Hardware Guide
5.
Grasp both ejector handles, pull firmly, and slide the SIB about three-quarters of the way out of the chassis.
6.
Place one hand underneath the SIB to support it and slide it completely out of the chassis. Place it on the antistatic mat.
CAUTION: Do not stack hardware components on one another after you remove them. Place each component on an antistatic mat resting on a stable, flat surface.
Figure 239: Removing a T1600-SIB
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Maintaining the T1600 SIBs on page 531
•
T1600 Switch Interface Board (SIB) Description on page 127
Installing a T1600-SIB
Each T1600-SIB weighs approximately 6.5 lb (3 kg). To install a T1600-SIB (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Place one hand underneath the T1600-SIB to support it. With the other hand, hold one of the ejector handles on the T1600-SIB faceplate.
480 Copyright © 2019, Juniper Networks, Inc.
Chapter 31: Replacing Switch Fabric Components
3.
Carefully align the sides of the T1600-SIB with the guides inside the chassis.
4.
Slide the T1600-SIB into the chassis, carefully ensuring that it is correctly aligned.
5.
Grasp both ejector handles and press them inward to seat the T1600-SIB. Ensure that the ejector handle tabs are properly mated inside their corresponding chassis slots.
You might have to close and open the handles a few times before the tabs catch the slots.
6.
Tighten the captive screws on the ejector handles.
7.
Bring the T1600-SIB online using one of the following methods:
• Press and hold the ONLINE/OFFLINE button on the T1600-SIB faceplate. The green
OK LED on the faceplate begins to blink. Hold the button down until the LED blinks.
• Issue the following CLI command on the router: user@host> request chassis sib online slot 0
Figure 240: Installing a T1600-SIB in a T1600
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588 .
•
Maintaining the T1600 SIBs on page 531
•
T1600 Switch Interface Board (SIB) Description on page 127
Copyright © 2019, Juniper Networks, Inc.
481
T1600 Core Router Hardware Guide
Verifying the Installation of a T1600-SIB
To verify that the T1600-SIB is functioning normally:
1.
Check the LEDs on the T1600-SIB faceplate.
• The green OK LED should light steadily a few minutes after the T1600-SIB is installed.
• If the FAIL LED is lit steadily, remove and install the T1600-SIB again. Make sure that the T1600-SIB is seated properly. If the FAIL LED still lights steadily, the
T1600-SIB is not functioning properly. Contact your customer support representative.
2.
Verify that four T1600-SIBs are in the Online state and one SIB is in the Spare state.
Display the status of the T1600-SIB by issuing the show chassis sibs command: user@host> show chassis sibs
Slot State Uptime
0 Spare 0 days, 30 minutes, 12 seconds
1 Online 0 days, 25 minutes, 45 seconds
2 Online 0 days, 20 minutes, 28 seconds
3 Online 0 days, 15 minutes, 7 seconds
4 Online 0 days, 10 minutes, 52 seconds
To bring a T1600-SIB online, issue the request chassis sib online operational mode command.
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Maintaining the T1600 SIBs on page 531
•
T1600 Switch Interface Board (SIB) Description on page 127
Related
Documentation
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Maintaining the T1600 SIBs on page 531
•
T1600 Switch Interface Board (SIB) Description on page 127
Replacing a TXP-T1600 SIB
1.
Removing a TXP-T1600 SIB on page 483
2.
Installing a TXP-T1600 SIB on page 484
3.
Verifying the Installation of a TXP-T1600 SIB on page 486
482 Copyright © 2019, Juniper Networks, Inc.
Chapter 31: Replacing Switch Fabric Components
Removing a TXP-T1600 SIB
Five SIBs are installed in the router. The SIBs are located in the rear of the chassis in the slots marked SIB0 through SIB4 . Each TXP-T1600 SIB weighs 10.2 lb (4.6 kg).
To remove the TXP-T1600 SIBs (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Ensure the fiber-optic array cables connected to to the TXP-T1600 SIB are labeled so you can reconnect them correctly.
4.
Use one of the following methods to take the TXP-T1600 SIB offline:
• Issue the request chassis sib lcc number slot slot-number offline command. For example: user@host> request chassis sib lcc 0 slot 3 offline
Online initiated, use "show chassis sibs" to verify
• Press and hold the SIB ONLINE/OFFLINE button in the middle of the TXP-T1600
SIB faceplate to take the SIB offline. Hold the buttons down until all the LEDs on the faceplate are not lit.
5.
Remove all four fiber-optic array cables from the TXP-T1600 SIB.
WARNING: Do not look directly into a fiber-optic array port or a connector at the end of a fiber-optic array cable connected to a port. The fiber optics emit laser light that can damage your eyes.
6.
Install a dust cover on each cable you removed from the TXP-T1600 SIB. Align the dust cover with the cable and carefully press them together until they stop. The cover and the cable are keyed to ensure proper mating.
7.
Move the fiber-optic array cables to the side of the TXP-T1600 SIB so they do not interfere with the removal of the TXP-T1600 SIB.
8.
Loosen the captive screws (using a Phillips (+) screwdriver, number 2) on the ejector handles on each side of the SIB faceplate.
9.
Flip the ejector handles outward to unseat the SIB.
Copyright © 2019, Juniper Networks, Inc.
483
T1600 Core Router Hardware Guide
10.
Grasp both ejector handles, pull firmly, and slide the SIB about three-quarters of the way out of the chassis.
11.
Place one hand underneath the SIB to support it and slide it completely out of the chassis. Place it on the antistatic mat.
CAUTION: Do not stack hardware components on one another after you remove them. Place each component on an antistatic mat resting on a stable, flat surface.
Figure 241: Removing a TXP-T1600 SIB
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
Installing a TXP-T1600 SIB
Each TXP-T1600 SIB weighs approximately 10.2 lb (4.6 kg). To install a TXP-T1600 SIB
(see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Place one hand underneath the TXP-T1600 SIB to support it. With the other hand, hold one of the ejector handles on the TXP-T1600 SIB faceplate.
484 Copyright © 2019, Juniper Networks, Inc.
Chapter 31: Replacing Switch Fabric Components
3.
Carefully align the sides of the TXP-T1600 SIB with the guides inside the chassis.
4.
Slide the TXP-T1600 SIB into the chassis, carefully ensuring that it is correctly aligned.
5.
Grasp both ejector handles and press them inward to seat the TXP-T1600 SIB. Ensure that the ejector handle tabs are properly mated inside their corresponding chassis slots. You might have to close and open the handles a few times before the tabs catch the slots.
6.
Tighten the captive screws on the ejector handles.
7.
Remove the dust cover from covering each TXP-F13 SIB fiber-optic array port.
8.
Remove the dust covers from the fiber-optic array cable connectors.
9.
Clean the fiber-optic array ports and cables.
CAUTION: While you replace a fiber-optic array cable, small deposits of oil, dust, and debris can enter the TXP-F13 SIB and TXP-T1600 SIB fiber-optic array ports, the fiber-optic array cables. We recommend that you clean the optics in these components, as well as the dust covers, immediately before connecting them.
10.
Connect each cable to its corresponding TXP-T1600 port. Align the cable with its corresponding TXP-T1600 SIB port and carefully press it into the port until it stops.
The cable and port are keyed to ensure proper mating.
NOTE: The optics in a fiber-optic array port are spring loaded, so you must continue to apply force to a fiber-optic array cable or loopback connector while securing it to a TXP-T1600 SIB.
11.
Bring the TXP-T1600 SIB online using one of the following methods:
• Press and hold the ONLINE/OFFLINE button on the TXP-T1600 SIB faceplate. The green OK LED on the faceplate begins to blink. Hold the button down until the LED blinks.
• Issue the following CLI command on the router: user@host> request chassis sib online slot 0
Copyright © 2019, Juniper Networks, Inc.
485
T1600 Core Router Hardware Guide
Figure 242: Installing a TXP-T1600 SIB
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
Verifying the Installation of a TXP-T1600 SIB
To verify that the TXP-T1600 is functioning normally:
1.
Check the LEDs on the TXP-T1600 faceplate. A few minutes after the TXP-T1600 is installed:
• The green OK LED should light steadily, indicating that the TXP-T1600 SIB is installed correctly.
• The green LINK port LED should light steadily, indicating that the link between the
TXP-F13 SIB port and the TXP-T1600 SIB port has been established successfully.
• The green RxPWR port LED should light steadily, indicating that full optical power is being received.
• The green OK LED should light steadily a few minutes after the TXP-T1600 is installed.
• If the FAIL LED is lit steadily, remove and install the TXP-T1600 again. Make sure that the TXP-T1600 is seated properly. If the FAIL LED still lights steadily, the
TXP-T1600 is not functioning properly. Contact your customer support representative.
2.
Verify that four TXP-T1600s are in the Online state and one SIB is in the Spare state.
Display the status of the TXP-T1600 by issuing the show chassis sibs command:
486 Copyright © 2019, Juniper Networks, Inc.
Chapter 31: Replacing Switch Fabric Components user@host> show chassis sibs
Slot State Uptime
0 Spare 0 days, 30 minutes, 12 seconds
1 Online 0 days, 25 minutes, 45 seconds
2 Online 0 days, 20 minutes, 28 seconds
3 Online 0 days, 15 minutes, 7 seconds
4 Online 0 days, 10 minutes, 52 seconds
To bring a TXP-T1600 online, issue the request chassis sib online operational mode command.
See Also •
TXP-T1600 SIB Description on page 129
•
TXP-T1600 SIB LEDs on page 130
•
Cleaning Fiber-Optic Array Components with the Dry Cloth Cleaning Tool on page 532
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Related
Documentation
•
TXP-T1600 SIB Description on page 129
•
TXP-T1600 SIB LEDs on page 130
•
Cleaning Fiber-Optic Array Components with the Dry Cloth Cleaning Tool on page 532
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Replacing a T1600 TXP-LCC-3D SIB
Five SIBs are located in the rear of the chassis in the slots marked SIB0 through SIB4 .
The TXP-LCC-3D SIBs connect to the TXP-F13-3D SIBs in a TX Matrix Plus router.
TXP-LCC-3D SIBs in active data switching planes are hot-pluggable. TXP-LCC-3D SIBs in a spare data switching planes are hot-insertable and hot-removable. When you remove a TXP-LCC-3D SIB in a spare switching plane, traffic forwarding continues without any degradation as long as the other four switching planes remain online. However, removing a TXP-LCC-3D SIB in an active switching plane might cause performance degradation in that switching plane. To avoid performance degradation, you can take the switching plane offline before you remove a TXP-LCC-3D SIB. For more information, see the TX
Matrix Plus Router Hardware Guide
1.
Removing a T1600 TXP-LCC-3D SIB on page 488
2.
Installing a T4000 TXP-LCC-3D SIB on page 490
Copyright © 2019, Juniper Networks, Inc.
487
T1600 Core Router Hardware Guide
Removing a T1600 TXP-LCC-3D SIB
Each TXP-LCC-3D SIB weighs approximately 9.4 lb (4.2 kg). To remove a TXP-LCC-3D
SIB (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Ensure that the cables connected to the TXP-3D-LCC SIB are labeled so you can reconnect them correctly.
4.
Use one of the following methods to take the TXP-LCC-3D SIB offline:
• Issue the request chassis sib lcc number slot slot-number offline command. For example: user@host> request chassis sib lcc 0 slot 3 offline
Online initiated, use "show chassis sibs" to verify
• Press and hold the SIB ONLINE/OFFLINE button in the middle of the TXP-LCC-3D
SIB faceplate to take the SIB offline. Hold the buttons down until all the LEDs on the faceplate are not lit.
5.
Remove each switching plane cable from the SIB.
•
CXP—Disconnect the CXP cables ( Figure 243 on page 489 ) from the CXP transceivers.
After all the CXP cables have been disconnected from the transceivers, remove the
CXP transceivers ( Figure 244 on page 489
) from the SIB.
WARNING: Do not look directly into a CXP cable connected to a port.
The fiber optics emit laser light that can damage your eyes.
• AOC—Remove the AOC transceivers from the SIB (
).
6.
Install dust covers on the cables and transceivers that you removed. Align the dust cover with the cable or transceiver and carefully press them together until they stop.
The dust cover and the cable or transceiver are keyed to ensure proper mating.
• CXP—Install a dust cover on each CXP transceiver and CXP cable.
• AOC—Install a dust cover on each AOC transceiver.
7.
Move the cables to the side of the SIB so they do not interfere with the removal of the
SIB.
8.
Using a Phillips (+) screwdriver, number 2, loosen the captive screws on the ejector handles on each side of the SIB faceplate.
488 Copyright © 2019, Juniper Networks, Inc.
Chapter 31: Replacing Switch Fabric Components
9.
Flip the ejector handles outward to unseat the SIB.
10.
Grasp both ejector handles, pull firmly, and slide the SIB about three-quarters of the way out of the chassis.
11.
Place one hand underneath the SIB to support it, and slide it completely out of the chassis. Place it on the antistatic mat.
CAUTION: Do not stack hardware components on one another after you remove them. Place each component on an antistatic mat resting on a stable, flat surface.
Figure 243: CXP Cable and Dust Cover
CXP switching plane cable CXP switching plane cable with dust cover
Figure 244: CXP Transceiver and Dust Cover
CXP transceiver
CXP transceiver with dust cover
Figure 245: AOC Transceiver and Dust Cover
AOC switching plane cable and transceiver
AOC switching plane cable and transceiver with dust cover
Copyright © 2019, Juniper Networks, Inc.
489
T1600 Core Router Hardware Guide
Figure 246: Installing a TXP-LCC-3D SIB
Installing a T4000 TXP-LCC-3D SIB
To install a TXP-LCC-3D SIB (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Place one hand underneath the SIB to support it. With the other hand, hold one of the ejector handles on the SIB.
3.
Carefully align the sides of the SIB with the guides inside the chassis.
4.
Slide the SIB into the chassis, carefully ensuring that it is correctly aligned.
5.
Grasp both ejector handles, and press them inward to seat the SIB. Ensure that the ejector handle tabs are properly mated inside their corresponding chassis slots. You might have to close and open the handles a few times before the tabs catch the slots.
6.
Tighten the captive screws on the ejector handles.
7.
Remove the dust covers from the transceivers and cables. Store the dust covers in a dust-free resealable plastic bag.
490 Copyright © 2019, Juniper Networks, Inc.
Chapter 31: Replacing Switch Fabric Components
8.
Insert the transceiver into the ports.
• CXP—Insert the CXP transceivers into the TXP-LCC-3D ports. The CXP transceivers and the port are keyed to ensure proper mating. After all the CXP transceiver have
been installed, reconnect each CXP cable ( Figure 247 on page 492
) to the CXP transceiver in the TXP-LCC-3D port that corresponds to the label on the cable.
Align the cable with the port and carefully press it into the port until it your hear a click and it stops. The CXP cables and CXP transceivers are keyed to ensure proper mating.
• AOC—Using the cable labels, insert each AOC transceiver into its corresponding
TXP-F13-3D port ( Figure 248 on page 492
).
Align the transceiver with the port and carefully press it into the port until it your hear a click and it stops. The AOC transceivers and the port are keyed to ensure proper mating.
9.
Bring the TXP-LCC-3D SIB online using one of the following methods:
• Press and hold the ONLINE/OFFLINE button on the TXP-LCC-3D SIB faceplate. The green OK LED on the faceplate begins to blink. Hold the button down until the LED blinks.
• Issue the following CLI command on the router: user@host> request chassis sib online slot 0
10.
Check the LEDs on the TXP-LCC-3D SIB faceplate.
• The green OK LED should light steadily a few minutes after the SIB is installed.
• If the FAIL LED is lit steadily, remove and install the TXP-LCC-3D SIB again. Make sure that the SIB is seated properly. If the FAIL LED still lights steadily, the SIB is not functioning properly. Contact your customer support representative.
11.
Verify that four SIBs are in the Online state and one SIB is in the Spare state. Display the status of the SIB by issuing the show chassis sibs command: user@host> show chassis sibs
Slot State Uptime
0 Spare
1 Online 1 day, 13 hours, 16 minutes, 49 seconds
2 Online 1 day, 13 hours, 16 minutes, 33 seconds
3 Online 1 day, 13 hours, 16 minutes, 16 seconds
4 Online 1 day, 13 hours, 16 minutes
If a SIB is not online, issue the request chassis sib online operational mode command.
Copyright © 2019, Juniper Networks, Inc.
491
T1600 Core Router Hardware Guide
Figure 247: Connecting a CXP Cable to a CXP Transceiver
CXP transceiver
TXP-LCC-3D
SIB
Figure 248: Installing an AOC Transceiver
CXP cable
AOC transceiver
TXP-LCC-3D
SIB
492 Copyright © 2019, Juniper Networks, Inc.
Figure 249: Installing a TXP-LCC-3D SIB
Chapter 31: Replacing Switch Fabric Components
Related
Documentation
•
T1600 TXP-LCC-3D SIB Description on page 131
•
Maintaining the T1600 SIBs on page 531
•
Troubleshooting the T1600 SIBs on page 557
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Replacing a T1600 SFP
1.
Removing a T1600 SFP on page 494
2.
Installing a T1600 SFP on page 495
Copyright © 2019, Juniper Networks, Inc.
493
T1600 Core Router Hardware Guide
Removing a T1600 SFP
Small form-factor pluggables (SFPs) are transceivers that can be removed from a PIC.
SFPs are hot-insertable and hot-removable. Removing an SFP does not interrupt PIC functioning, but the removed SFP no longer receives or transmits data.
NOTE: When you remove a PIC transceiver, the router continues to function, although the PIC interface being removed no longer functions.
Figure 250: Small Form-Factor Pluggable (SFP)
Connector
Locking pin
NOTE: This procedure applies to both SFP and SFP+ transceivers.
To remove an SFP transceiver (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface to receive the
SFP. Have ready a rubber safety cap for the SFP transceiver and the cable.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Label the cable connected to the SFP so that you can later reconnect it to the correct
SFP.
4.
Disconnect the cable from the SFP. Immediately cover the transceiver and the end of the cable with a rubber safety cap.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
494 Copyright © 2019, Juniper Networks, Inc.
Chapter 31: Replacing Switch Fabric Components
5.
Arrange the cable in the cable management system to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
6.
Pull the ejector handle away from the SFP faceplate to unseat the SFP from the PIC.
Pull the SFP out of the PIC, and place it on the antistatic mat or in the electrostatic bag.
CAUTION: After removing a transceiver from the chassis, wait at least 30 seconds before reinserting it or inserting a transceiver into a different slot.
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Replacing a T1600 PIC Cable on page 408
•
T1600 General Laser Safety Guidelines on page 603
•
Laser Safety Warnings for Juniper Networks Devices on page 604
Installing a T1600 SFP
To install a replacement SFP:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Verify that a rubber safety cap covers the SFP transceiver, installing one if necessary.
3.
Orient the SFP over the port in the PIC so that the connector end will enter the slot first and the SFP connector faces the appropriate direction:
• If the PIC has ten SFP ports, the ports are arranged in two columns. The SFP connector faces to the right for ports in the left column, and to the left for ports in the right column.
• If the PIC has one or two SFP ports, the SFP connector faces to the left.
4.
Slide the SFP into the slot. If there is resistance, remove the SFP and flip it so that the connector faces the other direction.
Copyright © 2019, Juniper Networks, Inc.
495
T1600 Core Router Hardware Guide
496
5.
Remove the rubber safety cap from the transceiver and the end of the cable, and insert the cable into the transceiver.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
6.
Arrange the cable in the cable management system to prevent the cable from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
7.
Verify that the status LEDs on the PIC faceplate indicate that the SFP is functioning correctly (there is an LED for each SFP port). For more information about the PIC
LEDs, see the interface module reference for your device. You can also verify PIC functioning by issuing the show chassis fpc pic-status command.
See Also • T1600 Core Router Interface Module Reference
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Replacing a T1600 PIC Cable on page 408
•
T1600 General Laser Safety Guidelines on page 603
•
Laser Safety Warnings for Juniper Networks Devices on page 604
Related
Documentation
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Replacing a T1600 PIC Cable on page 408
Copyright © 2019, Juniper Networks, Inc.
Chapter 31: Replacing Switch Fabric Components
•
T1600 General Laser Safety Guidelines on page 603
•
Laser Safety Warnings for Juniper Networks Devices on page 604
Replacing a T1600 XFP
1.
Removing a T1600 XFP on page 497
2.
Installing a T1600 XFP on page 498
Removing a T1600 XFP
10-Gigabit small form-factor pluggables (XFPs) are hot-insertable and hot-removable.
Removing an XFP does not interrupt PIC functioning, but the removed XFP no longer receives or transmits data.
To remove an XFP:
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface to receive the
XFP. Have ready a rubber safety cap for the XFP transceiver and the cable.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Label the cable connected to the XFP so that you can later reconnect it to the correct
XFP.
4.
Disconnect the cable from the XFP. Immediately cover the transceiver and the end of the cable with a rubber safety cap.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
5.
Arrange the cable in the cable management system, to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
Copyright © 2019, Juniper Networks, Inc.
497
T1600 Core Router Hardware Guide
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
6.
Pull the ejector handle away from the XFP faceplate to unseat the XFP from the PIC.
Pull the XFP out of the PIC and place it on the antistatic mat or in the electrostatic bag.
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Replacing a T1600 PIC Cable on page 408
•
T1600 General Laser Safety Guidelines on page 603
•
Laser Safety Warnings for Juniper Networks Devices on page 604
Installing a T1600 XFP
To install a replacement XFP:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Verify that a rubber safety cap covers the XFP transceiver, installing one if necessary.
3.
Orient the XFP over the port in the PIC so that the connector end will enter the slot first and the XFP connector faces the appropriate direction.
4.
Slide the XFP into the slot. If there is resistance, remove the XFP and flip it so that the connector faces the other direction.
5.
Remove the rubber safety cap from the transceiver and the end of the cable, and insert the cable into the transceiver.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes..
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
498 Copyright © 2019, Juniper Networks, Inc.
Chapter 31: Replacing Switch Fabric Components
6.
Arrange the cable in the cable management system to prevent the cable from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
7.
Verify that the status LEDs on the PIC faceplate indicate that the XFP is functioning correctly (there is an LED for each XFP port). For more information about the PIC
LEDs, see the T1600 Core Router Interface Module Reference . You can also verify PIC functioning by issuing the show chassis fpc pic-status command described in
“Maintaining T1600 PICs and PIC Cables” on page 523
.
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Replacing a T1600 PIC Cable on page 408
•
T1600 General Laser Safety Guidelines on page 603
•
Laser Safety Warnings for Juniper Networks Devices on page 604
Related
Documentation
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Replacing a T1600 PIC Cable on page 408
•
T1600 General Laser Safety Guidelines on page 603
•
Laser Safety Warnings for Juniper Networks Devices on page 604
Replacing a T1600 XENPAK Module
1.
Removing the T1600 XENPAK Module on page 500
2.
Installing the T1600 XENPAK Module on page 501
Copyright © 2019, Juniper Networks, Inc.
499
T1600 Core Router Hardware Guide
Removing the T1600 XENPAK Module
To remove a XENPAK module (see
):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface to receive the
XENPAK module. Have ready a rubber safety cap for the XENPAK transceiver and the cable.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Label the cable connected to the XENPAK module so that you can later reconnect it to the correct module.
4.
Disconnect the cable from the XENPAK module. Immediately cover the transceiver and the end of the cable with a rubber safety cap.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
5.
Arrange the cable in the cable management system to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
6.
Unscrew the thumbscrews at the top and bottom of the XENPAK module.
7.
Slide the module out of the PIC and place it in the electrostatic bag or on the antistatic mat.
500 Copyright © 2019, Juniper Networks, Inc.
Figure 251: Removing a XENPAK Module
Chapter 31: Replacing Switch Fabric Components
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Replacing a T1600 PIC Cable on page 408
•
T1600 General Laser Safety Guidelines on page 603
•
Laser Safety Warnings for Juniper Networks Devices on page 604
Installing the T1600 XENPAK Module
To install a replacement XENPAK module (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Verify that a rubber safety cap covers the XENPAK transceiver. Install one if necessary.
3.
Orient the XENPAK module so that the optical port faces out, and the transmit (TX) port is above the receive (RX) port (see
).
4.
Slide the XENPAK module into the slot.
5.
Tighten the thumbscrews at the top and bottom of the XENPAK module. Verify that the module is seated properly.
6.
Remove the rubber safety cap from the transceiver and the end of the cable. Insert the cable into the transceiver.
Copyright © 2019, Juniper Networks, Inc.
501
T1600 Core Router Hardware Guide
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
7.
Arrange the cable in the cable management system to prevent the cable from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
8.
Verify that the status LEDs on the PIC faceplate indicate that the XENPAK module is functioning correctly. For more information about the PIC LEDs, see the interface module reference for your device. You can also verify PIC functioning by issuing the show chassis fpc pic-status command.
502 Copyright © 2019, Juniper Networks, Inc.
Figure 252: Installing a XENPAK Module
Chapter 31: Replacing Switch Fabric Components
See Also •
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Replacing a T1600 PIC Cable on page 408
•
T1600 General Laser Safety Guidelines on page 603
•
Laser Safety Warnings for Juniper Networks Devices on page 604
Related
Documentation
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Replacing a T1600 PIC Cable on page 408
•
T1600 General Laser Safety Guidelines on page 603
•
Laser Safety Warnings for Juniper Networks Devices on page 604
Copyright © 2019, Juniper Networks, Inc.
503
T1600 Core Router Hardware Guide
504 Copyright © 2019, Juniper Networks, Inc.
PART 5
Maintaining the Chassis and Components
•
Routine Maintenance Procedures on page 507
•
Maintaining Components on page 509
Copyright © 2019, Juniper Networks, Inc.
505
T1600 Core Router Hardware Guide
506 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 32
Routine Maintenance Procedures
•
Routine Maintenance Procedures for the T1600 Router on page 507
Routine Maintenance Procedures for the T1600 Router
Purpose For optimum router performance, perform preventive maintenance procedures.
NOTE: Some components, such as the Connector Interface Panel (CIP) and the craft interface, require no maintenance.
Action On a regular basis:
• Inspect the installation site for moisture, loose wires or cables, and excessive dust.
Make sure that airflow is unobstructed around the router and into the air intake vents.
• Check the status-reporting devices on the craft interface: system alarms, LEDs, and
LCD.
• Inspect the air filters at the bottom front and left rear of the router, replacing them every 6 months. Do not run the router for more than a few minutes without the air filters in place.
Related
Documentation
•
T1600 Craft Interface Description on page 33
•
Maintaining the T1600 Air Filters on page 510
•
T1600 Router Description on page 3
Copyright © 2019, Juniper Networks, Inc.
507
T1600 Core Router Hardware Guide
508 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 33
Maintaining Components
•
Tools and Parts Required to Maintain the T1600 Hardware Components on page 509
•
Maintaining the T1600 Air Intake Vents on page 510
•
Maintaining the T1600 Air Filters on page 510
•
Maintaining the T1600 Control Boards on page 511
•
Maintaining the T1600 Fan Trays on page 512
•
Maintaining T1600 FPCs on page 514
•
Holding T1600 FPCs on page 515
•
Storing T1600 FPCs on page 520
•
Maintaining the T1600 Host Subsystem on page 520
•
Maintaining T1600 PICs and PIC Cables on page 523
•
Maintaining the T1600 Power Supplies on page 525
•
Maintaining the T1600 Routing Engines on page 529
•
Maintaining the T1600 SCGs on page 530
•
Maintaining the T1600 SIBs on page 531
•
Cleaning Fiber-Optic Array Components with the Dry Cloth Cleaning Tool on page 532
Tools and Parts Required to Maintain the T1600 Hardware Components
To maintain the T320 hardware components, you need the following tools and parts:
• ESD grounding wrist strap
• Flat-blade (–) screwdriver
• Phillips (+) screwdriver, number 1
• Phillips (+) screwdriver, number 2
Related
Documentation
•
Contacting Customer Support on page 565
•
Routine Maintenance Procedures for the T1600 Router on page 507
Copyright © 2019, Juniper Networks, Inc.
509
T1600 Core Router Hardware Guide
Maintaining the T1600 Air Intake Vents
Purpose For optimum cooling, verify the condition of the air intake vents. Dust can clog air intake vents, reducing cooling system efficiency.
Action On a regular basis, check the vents and clean them as necessary.
Related
Documentation
•
Clearance Requirements for Airflow and T1600 Hardware Maintenance on page 143
•
T1600 Cooling System Description on page 39
Maintaining the T1600 Air Filters
Purpose For optimum cooling, verify the condition of the air filters.
Air filters for both the front and rear fan trays help keep dust and other particles from entering the cooling system. To function properly, the entire cooling system requires an unobstructed airflow and proper clearance around the site, as described in
Requirements for Airflow and T1600 Hardware Maintenance” on page 143 .
Figure 253: Airflow Through the Chassis
510
Action Check the air filters regularly for dust and debris. The filter elements degrade over time, so the filter elements in use, must be replaced every 6 months. For procedures to replace the air filters, see
“Replacing the T1600 Rear Air Filter” on page 316
and
T1600 Front Air Filter” on page 313 .
The shelf life of polyurethane filter varies from two years to five years depending on the storage conditions. Store in a cool, dry, and dark environment. Wrap the media in plastic and store in an environment with relative humidity between 40%- 80% and temperature between 40°F (4° C) to 90°F (32° C). Note that if the material flakes, or becomes brittle when rubbed or deformed, it is no longer usable.
Copyright © 2019, Juniper Networks, Inc.
Chapter 33: Maintaining Components
CAUTION: Always keep both air filters in place while the router is operating.
Because the fans are very powerful, they could pull small bits of wire or other materials into the router through the unfiltered air intake. This could damage the router components.
Related
Documentation
•
T1600 Cooling System Description on page 39
Maintaining the T1600 Control Boards
Purpose For optimum router performance, verify the condition of the control boards.
Action On a regular basis:
• Check the host subsystem LEDs on the craft interface. For more information about the
LEDs and the display, see
“T1600 Craft Interface Description” on page 33 .
During normal operations:
• The green host subsystem OK LED on the craft interface is lit.
• The red host subsystem OK LED on the craft interface is not lit.
• Check the LEDs on the control board faceplate.
During normal operations:
• The green OK LED on the control board faceplate is lit.
• The yellow FAIL LED on the control board faceplate is not lit.
• Issue the show chassis environment cb command to check the status of the T-CBs.
The output is similar to the following: user@host> show chassis environment cb
CB 0 status:
State Online Master
Temperature 29 degrees C / 84 degrees F
Power:
1.8 V 1809 mV
2.5 V 2496 mV
3.3 V 3295 mV
4.6 V 4687 mV
5.0 V 5042 mV
12.0 V 11985 mV
3.3 V bias 3277 mV
8.0 V bias 7472 mV
GBUS Revision 40
FPGA Revision 7
Copyright © 2019, Juniper Networks, Inc.
511
T1600 Core Router Hardware Guide
For further description of the output from the commands, see show chassis environment cb .
Related
Documentation
•
T1600 Control Boards Description on page 74
•
T1600 Chassis Description on page 21
•
.
•
•
Troubleshooting the T1600 Host Subsystems on page 547
Maintaining the T1600 Fan Trays
Purpose For optimum cooling, verify the condition of the fans.
Action On a regular basis:
• Monitor the status of the fans. The fan trays each contain multiple fans that work in unison to cool the router components. If one fan fails, the host subsystem adjusts the speed of the remaining fans to maintain proper cooling. A red alarm is triggered when a fan fails, and a yellow alarm is triggered when a fan tray is removed. During normal operation, the fans in each fan tray function at normal speed.
• To display the status of the fans, issue the show chassis environment or show chassis fan command.
For the standard fan trays, the output for the show chassis environment command is similar to the following: user@host> show chassis environment
Class Item Status Measurement
...
Fans Top Left Front fan OK Spinning at normal speed
Top Left Middle fan OK Spinning at normal speed
Top Left Rear fan OK Spinning at normal speed
Top Right Front fan OK Spinning at normal speed
Top Right Middle fan OK Spinning at normal speed
Top Right Rear fan OK Spinning at normal speed
Bottom Left Front fan OK Spinning at normal speed
Bottom Left Middle fan OK Spinning at normal speed
Bottom Left Rear fan OK Spinning at normal speed
Bottom Right Front fan OK Spinning at normal speed
Bottom Right Middle fan OK Spinning at normal speed
Bottom Right Rear fan OK Spinning at normal speed
Rear Tray Top fan OK Spinning at normal speed
Rear Tray Second fan OK Spinning at normal speed
Rear Tray Third fan OK Spinning at normal speed
Rear Tray Fourth fan OK Spinning at normal speed
Rear Tray Fifth fan OK Spinning at normal speed
Rear Tray Sixth fan OK Spinning at normal speed
Rear Tray Seventh fan OK Spinning at normal speed
Rear Tray Bottom fan OK Spinning at normal speed...
512 Copyright © 2019, Juniper Networks, Inc.
Chapter 33: Maintaining Components
Top Left and Top Right refer to fans in the upper front fan tray.
Bottom Left and Bottom
Right refer to fans in the lower front fan tray.
Rear refers to the fans in the rear fan tray.
For the quiet fan trays, the output for the show chassis environment command is similar to the following: user@host> show chassis environment
Class Item Status Measurement
Fans Top Left Front fan OK Spinning at normal speed
Top Left Rear fan OK Spinning at normal speed
Top Right Front fan OK Spinning at normal speed
Top Right Rear fan OK Spinning at normal speed
Bottom Left Front fan OK Spinning at normal speed
Bottom Left Rear fan OK Spinning at normal speed
Bottom Right Front fan OK Spinning at normal speed
Bottom Right Rear fan OK Spinning at normal speed
Rear Tray Top fan OK Spinning at normal speed
Rear Tray Second fan OK Spinning at normal speed
Rear Tray Third fan OK Spinning at normal speed
Rear Tray Fourth fan OK Spinning at normal speed
Rear Tray Fifth fan OK Spinning at normal speed
Rear Tray Sixth fan OK Spinning at normal speed
Rear Tray Seventh fan OK Spinning at normal speed
Rear Tray Bottom fan OK Spinning at normal speed
Top Left and Top Right refer to fans in the upper front fan tray.
Bottom Left and Bottom
Right refer to fans in the lower front fan tray.
Rear refers to the fans in the rear fan tray.
For the standard fan trays, the output for the show chassis fan command is similar to the following: user@host> show chassis fan
Item Status RPM Measurement
Top Left Front fan OK 3420 Spinning at normal speed
Top Left Middle fan OK 3420 Spinning at normal speed
Top Left Rear fan OK 3450 Spinning at normal speed
Top Right Front fan OK 3420 Spinning at normal speed
Top Right Middle fan OK 3420 Spinning at normal speed
Top Right Rear fan OK 3420 Spinning at normal speed
Bottom Left Front fan OK 3420 Spinning at normal speed
Bottom Left Middle fan OK 3450 Spinning at normal speed
Bottom Left Rear fan OK 3360 Spinning at normal speed
Bottom Right Front fan OK 3420 Spinning at normal speed
Bottom Right Middle fan OK 3420 Spinning at normal speed
Bottom Right Rear fan OK 3420 Spinning at normal speed
Rear Tray Top fan OK 5190 Spinning at normal speed
Rear Tray Second fan OK 5190 Spinning at normal speed
Rear Tray Third fan OK 5190 Spinning at normal speed
Rear Tray Fourth fan OK 5190 Spinning at normal speed
Rear Tray Fifth fan OK 5190 Spinning at normal speed
Rear Tray Sixth fan OK 5190 Spinning at normal speed
Rear Tray Seventh fan OK 5190 Spinning at normal speed
Rear Tray Bottom fan OK 5190 Spinning at normal speed
For the quiet fan trays, the output for the show chassis fan command is similar to the following:
Copyright © 2019, Juniper Networks, Inc.
513
T1600 Core Router Hardware Guide user@host> show chassis fan
Item Status RPM Measurement
Top Left Front fan OK 2220 Spinning at normal speed
Top Left Rear fan OK 2190 Spinning at normal speed
Top Right Front fan OK 2220 Spinning at normal speed
Top Right Rear fan OK 2250 Spinning at normal speed
Bottom Left Front fan OK 2220 Spinning at normal speed
Bottom Left Rear fan OK 2220 Spinning at normal speed
Bottom Right Front fan OK 2250 Spinning at normal speed
Bottom Right Rear fan OK 2220 Spinning at normal speed
Rear Tray Top fan OK 5190 Spinning at normal speed
Rear Tray Second fan OK 5190 Spinning at normal speed
Rear Tray Third fan OK 5190 Spinning at normal speed
Rear Tray Fourth fan OK 5190 Spinning at normal speed
Rear Tray Fifth fan OK 5190 Spinning at normal speed
Rear Tray Sixth fan OK 5190 Spinning at normal speed
Rear Tray Seventh fan OK 5190 Spinning at normal speed
Rear Tray Bottom fan OK 5190 Spinning at normal speed
Related
Documentation
•
T1600 Cooling System Description on page 39
•
Troubleshooting the T1600 Cooling System on page 543
Maintaining T1600 FPCs
Purpose For optimum router performance, verify the condition of the FPCs. The router can have up to eight FPCs mounted vertically in the FPC card cage at the front of the chassis.
Action On a regular basis:
• Check the LCD on the craft interface and the LEDs on the craft interface directly above each FPC slot. The green LED labeled OK lights steadily when an FPC is functioning normally.
During normal operation:
• The green OK LED above the FPC on the craft interface lights steadily when the FPC is online and functioning normally.
• The green OK LED blinks during startup.
• Issue the CLI show chassis fpc command to check the status of installed FPCs. As shown in the sample output, the value Online in the column labeled State indicates that the FPC is functioning normally: user@host> show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online 37 2 0 256 9 41
1 Empty
2 Online 37 3 0 256 8 41
514 Copyright © 2019, Juniper Networks, Inc.
Chapter 33: Maintaining Components
3 Empty
4 Empty
5 Empty
6 Empty
7 Empty
For more detailed output, add the detail option. The following example also specifies a slot number ( 0 ), which is optional: user@host> show chassis fpc detail 0
Slot 0 information:
State Online
Temperature 37 degrees C / 98 degrees F
Total CPU DRAM 256 MB
Total SRAM 28 MB
Total SDRAM 256 MB
Start time: 2003-10-01 04:19:30 PDT
Uptime: 10 days, 7 hours, 16 minutes, 48 seconds
For further description of the output from the commands, see show chassis fpc .
Related
Documentation
•
T1600 Chassis Description on page 21
•
T1600 Craft Interface FPC LEDs on page 37
•
Replacing a T1600 FPC on page 395
•
T1600 Flexible PIC Concentrator (FPC) Description on page 81
Holding T1600 FPCs
•
Preventing Damage to FPCs on page 515
•
Holding T1600 FPCs Vertically on page 518
•
Holding T1600 FPCs Horizontally on page 519
Preventing Damage to FPCs
CAUTION: Many components on the FPC are fragile. Failure to handle FPCs as specified in this document can cause irreparable damage.
CAUTION: To prevent damage when handling or carrying FPCs:
• As you carry the FPC, do not bump it against anything. FPC components are fragile.
• Do not grasp the FPC anywhere except places that this document indicates.
In particular, never grasp the connector edge, especially at the power
Copyright © 2019, Juniper Networks, Inc.
515
T1600 Core Router Hardware Guide connector in the corner where the connector and bottom edges meet (see
).
• Do not carry the FPC by the faceplate with only one hand (see
• Do not rest any edge of an FPC directly against a hard surface (see
). If you must rest the FPC temporarily on an edge while changing its orientation between vertical and horizontal, use your hand as a cushion between the edge and the surface.
Figure 254: Do Not Grasp the Connector Edge
516 Copyright © 2019, Juniper Networks, Inc.
Figure 255: Do Not Carry an FPC with Only One Hand
Chapter 33: Maintaining Components
Figure 256: Do Not Rest the FPC on an Edge
Copyright © 2019, Juniper Networks, Inc.
517
T1600 Core Router Hardware Guide
Holding T1600 FPCs Vertically
NOTE: An FPC configured with PICs installed can weigh as much as
37 lb (14.5 kg). Be prepared to accept the full weight of the FPC as you lift it.
You hold an FPC vertically when installing it into the chassis. To hold an FPC vertically
(see
):
1.
Orient the FPC so that the faceplate faces you.
2.
Place one hand around the FPC faceplate about a quarter of the way down from the top edge. To avoid deforming the electromagnetic interference (EMI) shielding strip, do not press hard on it.
3.
Place your other hand at the bottom edge of the FPC. If the FPC has heat sinks about midway between the faceplate and connector edge, place your other hand against the heat sinks.
Figure 257: Holding an FPC Vertically
518 Copyright © 2019, Juniper Networks, Inc.
Chapter 33: Maintaining Components
Holding T1600 FPCs Horizontally
To hold an FPC horizontally:
1.
Orient the FPC so that the faceplate is facing you.
2.
Grasp the top edge with your left hand and the bottom edge with your right hand.
You can rest the faceplate of the FPC against your body as you carry it (see
Figure 258: Holding an FPC Horizontally
Related
Documentation
•
T1600 Flexible PIC Concentrator (FPC) Description on page 81
•
Replacing a T1600 FPC on page 395
•
Storing T1600 FPCs on page 520
Copyright © 2019, Juniper Networks, Inc.
519
T1600 Core Router Hardware Guide
Storing T1600 FPCs
When an FPC is not installed in a router, the FPC must be either stored in the container in which a spare FPC is shipped or stored horizontally with the component-side up on a flat, stable surface. When you store an FPC on a horizontal surface or in the shipping container, always place it inside an antistatic bag. Because the FPC is heavy and because antistatic bags are fragile, inserting the FPC into the bag is easier with two people. The storage procedures are as follows:
• When storing an FPC with two people, one person holds the FPC in the horizontal position with the faceplate facing their body, the other person slides the opening of the bag over the FPC connector edge.
• When storing an FPC with one person, you must insert the FPC into a bag by yourself.
First lay the FPC horizontally on a flat, stable surface, component-side up. Orient the
FPC with the faceplate facing you. Carefully insert the FPC connector edge into the opening of the bag, and pull the bag toward you to cover the FPC.
CAUTION: To prevent damage when storing FPCs:
• Never lay an FPC component-side down.
Figure 259: Do Not Stack FPCs
• Never stack an FPC under or on top of any other component (see
).
Related
Documentation
•
T1600 Flexible PIC Concentrator (FPC) Description on page 81
Maintaining the T1600 Host Subsystem
Each host subsystem comprises a Routing Engine and an adjacent control board functioning together.
To maintain the host subsystem, check the host subsystem LEDs ( HOST0 and HOST1 ) on the craft interface. If the red HOST0 FAIL or HOST1 FAIL LED is lit, look at the LCD to
520 Copyright © 2019, Juniper Networks, Inc.
Chapter 33: Maintaining Components get more information about the cause of the problem. For more information about the
LEDs and the display, see
“T1600 Craft Interface Description” on page 33
To maintain the Routing Engines and control boards:
•
Maintaining the T1600 Routing Engines on page 521
•
Maintaining the T1600 Control Boards on page 522
Maintaining the T1600 Routing Engines
Purpose For optimum router performance, verify the condition of the Routing Engines and the control boards.
Action On a regular basis:
• Check the LCD on the craft interface to view information about the router temperature and the status of the Routing Engines.
• Check the host subsystem LEDs on the craft interface. For more information about the
LEDs and the display, see
“T1600 Craft Interface Description” on page 33
. During normal operations:
• The green host subsystem OK LED on the craft interface is lit.
• The red host subsystem FAIL LED on the craft interface is not lit.
• Check the LEDs on the RE-2000 faceplate. During normal operations, the ONLINE LED is lit steadilygreen.
• Check the LEDs on the RE-C1800 faceplate. During normal operations, the ONLINE
LED is lit steadily green.
• Issue the show chassis routing-engine command to check the status of the Routing
Engines. The output is similar to the following: user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
Temperature 34 degrees C / 93 degrees F
DRAM 2048 Mbytes
CPU utilization:
User 0 percent
Background 0 percent
Kernel 1 percent
Interrupt 0 percent
Idle 99 percent
Start time 2002-01-22 05:21:31 UTC
Uptime 10 days, 16 hours, 4 minutes, 52 seconds
Load averages: 1 minute 5 minute 15 minute
0.00 0.00 0.00
Routing Engine status:
Slot 1:
Current state Empty
Copyright © 2019, Juniper Networks, Inc.
521
T1600 Core Router Hardware Guide
For further description of the output from the commands, see show chassis routing-engine .
See Also •
T1600 Routing Engine Description on page 44
•
•
•
•
T1600 RE-C1800 LEDs on page 51
•
Troubleshooting the T1600 Host Subsystems on page 547
Maintaining the T1600 Control Boards
Purpose For optimum router performance, verify the condition of the control boards.
Action On a regular basis:
• Check the host subsystem LEDs on the craft interface. For more information about the
LEDs and the display, see
“T1600 Craft Interface Description” on page 33 .
During normal operations:
• The green host subsystem OK LED on the craft interface is lit.
• The red host subsystem OK LED on the craft interface is not lit.
• Check the LEDs on the control board faceplate.
During normal operations:
• The green OK LED on the control board faceplate is lit.
• The yellow FAIL LED on the control board faceplate is not lit.
• Issue the show chassis environment cb command to check the status of the T-CBs.
The output is similar to the following: user@host> show chassis environment cb
CB 0 status:
State Online Master
Temperature 29 degrees C / 84 degrees F
Power:
1.8 V 1809 mV
2.5 V 2496 mV
3.3 V 3295 mV
4.6 V 4687 mV
5.0 V 5042 mV
12.0 V 11985 mV
3.3 V bias 3277 mV
8.0 V bias 7472 mV
GBUS Revision 40
522 Copyright © 2019, Juniper Networks, Inc.
Chapter 33: Maintaining Components
FPGA Revision 7
For further description of the output from the commands, see show chassis environment cb .
See Also •
T1600 Control Boards Description on page 74
•
T1600 Chassis Description on page 21
•
.
•
•
Troubleshooting the T1600 Host Subsystems on page 547
Related
Documentation
•
T1600 Host Subsystem Description on page 43
•
Troubleshooting the T1600 Host Subsystems on page 547
Maintaining T1600 PICs and PIC Cables
Purpose For optimum router performance, verify the condition of the PICs and PIC cables.
Action On a regular basis:
• Check the LEDs on PIC faceplates. A PIC LED lit green indicates the PIC is functioning normally. The meaning of the LED states differs for various PICs. For more information, see the interface module reference for your device. If the FPC that houses the PIC detects a PIC failure, the FPC generates an alarm message to be sent to the Routing
Engine.
• Issue the CLI show chassis fpc pic-status command. The PIC slots in an FPC are numbered from 0 through 3 , top to bottom: user@host> show chassis fpc pic-status
Slot 0 Online E-FPC Type 3
PIC 0 Online 1x 10GE(LAN),DWDM
PIC 2 Present 1x OC-192 SONET XFP- Hardware Error
PIC 3 Online 1x 10GE(LAN),XENPAK
Slot 2 Online E2-FPC Type 2
PIC 0 Online 1x OC-48 SONET, SMIR
PIC 1 Online 2x OC-12 ATM-II IQ, MM
PIC 2 Online 8x 1GE(LAN), IQ2
Slot 3 Online FPC Type 3
PIC 0 Online 1x 10GE(LAN),XENPAK
PIC 1 Online 1x 10GE(LAN),XENPAK
PIC 2 Online 8x 1GE(TYPE3), IQ2
PIC 3 Online 8x 1GE(TYPE3), IQ2
Slot 4 Online FPC Type 4
PIC 0 Online 4x OC-192 SONET XFP
Copyright © 2019, Juniper Networks, Inc.
523
T1600 Core Router Hardware Guide
Slot 6 Online FPC Type 3
PIC 0 Online 4x OC-48 SONET
PIC 1 Online 1x Tunnel
Slot 7 Online FPC Type 4
PIC 0 Online 1x OC-768 SONET SR
For further description of the output from the command, see show chassis fpc .
• Use the cable management system to support cables and prevent cables from dislodging or developing stress points.
• Place excess cable out of the way in the cable management system. Do not allow fastened loops of cable to dangle from the connector or cable management system, because this stresses the cable at the fastening point. Putting fasteners on the loops helps to maintain their shape.
• Keep the cable connections clean and free of dust and other particles, which can cause drops in the received power level. Always inspect cables and clean them if necessary before connecting an interface.
• Label both ends of PIC cables to identify them.
The following guidelines apply specifically to fiber-optic cable:
• When you unplug a fiber-optic cable from a PIC, always place a rubber safety plug over the transceiver on the PIC faceplate and on the end of the cable.
• Anchor fiber-optic cable to avoid stress on the connectors. When attaching fiber to a
PIC, be sure to secure the fiber so it is not supporting its own weight as it hangs to the floor. Never let fiber-optic cable hang free from the connector.
• Avoid bending fiber-optic cable beyond its bend radius. An arc smaller than a few inches can damage the cable and cause problems that are difficult to diagnose.
• Frequent plugging and unplugging of fiber-optic cable into and out of optical instruments, such as ATM or SONET/SDH analyzers, can cause damage to the instruments that is expensive to repair. Instead, attach a short fiber extension to the optical equipment. Any wear and tear due to frequent plugging and unplugging is then absorbed by the short fiber extension, which is easy and inexpensive to replace.
• Keep fiber-optic cable connections clean. Small microdeposits of oil and dust in the canal of the transceiver or cable connector could cause loss of light, reducing signal power and possibly causing intermittent problems with the optical connection.
To clean the transceivers, use an appropriate fiber-cleaning device, such as RIFOCS
Fiber Optic Adaptor Cleaning Wands (part number 946). Follow the directions for the cleaning kit you use.
After you have cleaned the transceiver on the fiber-optic PIC, make sure that the connector tip of the fiber-optic cable is clean. Use only an approved alcohol-free fiber-optic cable cleaning kit, such as the Opptex Cletop-S
®
Fiber Cleaner. Follow the directions for the cleaning kit you use.
524 Copyright © 2019, Juniper Networks, Inc.
Chapter 33: Maintaining Components
Related
Documentation
•
T1600 Chassis Description on page 21
•
Connecting PIC Cables to the T1600 Router on page 242
•
Replacing a T1600 PIC Cable on page 408
Maintaining the T1600 Power Supplies
Purpose For optimum router performance, verify the condition of the power supplies.
Action On a regular basis:
• Make sure that the power and grounding cables are arranged so that they do not obstruct access to other router components.
• The power supplies require an unobstructed airflow at both the front and rear of the chassis. Periodically check the site to ensure that both the air intake at the bottom front of the chassis and the exhaust from the power supply faceplates are unobstructed.
• Periodically inspect the site to ensure that the grounding and power cables connected to the router are securely in place and that no moisture accumulating near the router.
To review grounding and site wiring requirements for the router, see
Grounding Cable and Lug Specifications” on page 140
and
Guidelines for Juniper Networks Devices” on page 622 .
• Regularly inspect the air filters on each power supply for dust and debris, and replace the side filter on AC power supplies or front filter element on AC and DC power supplies every 6 months.
To replace a power supply air filter element, see the following topics:
•
Replacing a Front Air Filter on a T1600 AC or Three-Input 240-A or Four-Input 240-A
• Replacing a Side Air Filter on a T1600 AC Power Supply
•
Replacing a T1600 Six-Input DC Power Supply Front Air Filter on page 449
•
Replacing a T1600 Six-Input DC Power Supply Side Air Filter on page 449
• Routinely check the LEDs on the DC power supply faceplates.
During normal operation:
• For DC power supplies, the blue DC OK LEDs light to indicate that the power supplies are functioning normally.
• For DC power supplies, each green INPUT PRESENT LED on a DC power supply lights when the input is receiving source DC power.
• For three-input 240 -A power supplies and four-input 240 -A DC power supplies, each CB ON LED on a DC power supply lights when the circuit breaker is on.
Copyright © 2019, Juniper Networks, Inc.
525
T1600 Core Router Hardware Guide
• Routinely check the LEDs on the AC power supply faceplates. If the AC OK LEDs are lit, the AC terminal blocks are receiving power. If the DC OK LEDs are lit, the AC power supplies are functioning normally.
• Check the red and yellow alarm LEDs and the LCD on the craft interface. Power supply failure or removal triggers an alarm that causes one or both of the LEDs to light and an error message to appear on the LCD. You can display the associated error messages by issuing the following CLI command: user@host> show chassis alarms
• Issue the show chassis environment pem command to check the status of the power supplies.
• For DC-powered routers with three-input 240-A DC power supplies or four-input
240-A DC power supplies, the output is similar to the following: user@host> show chassis environment pem
PEM 0 status:
State Online
Temperature 41 degrees C / 105 degrees F
DC Input: OK
DC Output Voltage Current Power Load
FPC 0 56775 1362 77 10
FPC 1 57058 1318 75 10
FPC 2 57483 1293 74 9
FPC 3 57341 1318 75 10
FPC 4 57100 1381 78 10
FPC 5 57016 0 0 0
FPC 6 57000 0 0 0
FPC 7 56958 0 0 0
SCG/CB/SIB 56100 5975 335 27
PEM 1 status:
State Present
Temperature 33 degrees C / 91 degrees F
DC Input: Check
DC Output Voltage Current Power Load
FPC 0 0 0 0 0
526 Copyright © 2019, Juniper Networks, Inc.
Chapter 33: Maintaining Components
FPC 1 0 0 0 0
FPC 2 0 0 0 0
FPC 3 0 0 0 0
FPC 4 0 0 0 0
FPC 5 0 0 0 0
FPC 6 0 0 0 0
FPC 7 0 0 0 0
SCG/CB/SIB 0 0 0 0
If 0 is displayed for the SCG/CB/SIB in the Current, Power, and Load fields for a PEM, and the voltage field does not match the other PEM, it might indicate a difference between the DC input voltages applied to PEM0 and PEM1 . Consider checking your
DC power network for unintended voltage drops to the router (see
for a typical DC source cabling arrangement).
The current sharing between DC power supplies relies on equal voltages at the input terminals of the power supplies. However, if the voltages do not match, the router operates normally as long as the DC input voltages are within the operating range provided in
• For the three-input 240-A DC power supplies, system power is divided into two load zones. One load zone consists of INPUT 0 of PEM0 and PEM1 . The other load zones consist of INPUT 1 and INPUT 2 of PEM0 and PEM1 . Load sharing occurs between the two power supplies for each load zone. Therefore, the input voltage for the inputs in each load zone must be equal in both power supplies for current sharing. For example, the input voltage for INPUT 0 of PEM0 and the input voltage for INPUT 0 of PEM1 must be the same for current sharing to occur within that load zone.
• For the four-input 240-A DC power supplies, system power is divided into four load zones. One load zone consists of INPUT 0 of PEM0 and PEM1 . The other load zones consist of INPUT 1 , INPUT 2 and INPUT 3 of PEM0 and PEM1 . Load sharing occurs between the two power supplies for each load zone. Therefore, the input voltage for the inputs in each load zone must be equal in both power supplies for current sharing. For example, the input voltage for INPUT 0 of PEM0 and the input voltage for INPUT 0 of PEM1 must be the same for current sharing to occur within that load zone.
• For DC-powered routers with six-input DC power supplies, the output is similar to the following: user@host> show chassis environment pem
PEM 0 status:
State Online
Temperature 34 degrees C / 93 degrees F
Copyright © 2019, Juniper Networks, Inc.
527
T1600 Core Router Hardware Guide
528
DC Input: OK
Voltage(V) Current(A) Power(W) Load(%)
INPUT 0 53.500 7.437 397 52
INPUT 1 53.750 10.812 581 77
INPUT 2 53.125 9.562 507 67
INPUT 3 53.625 11.125 596 79
INPUT 4 53.750 9.875 530 70
INPUT 5 53.250 9.500 505 67
DC Output Voltage(V) Current(A) Power(W) Load(%)
FPC 0 0.000 0.000 0 0
FPC 1 0.000 0.000 0 0
FPC 2 0.000 0.000 0 0
FPC 3 0.000 0.000 0 0
FPC 4 55.375 9.562 529 70
FPC 5 0.062 0.000 0 0
FPC 6 55.062 9.000 495 66
FPC 7 55.437 9.000 498 66
SCG/CB/SIB 55.375 15.375 851 70
FAN 49.000 7.875 385 51
For AC-powered routers, the output is similar to the following: user@host> show chassis environment pem
PEM 1 status:
State Online
Temperature 33 degrees C / 91 degrees F
AC Input: OK
DC Output Voltage(mV) Current(mA) Power(W) Load(%)
FPC 0 55183 7056 389 51
FPC 1 55633 7018 390 52
FPC 2 55533 5187 288 38
FPC 3 55533 7081 393 52
FPC 4 55508 6612 367 48
FPC 5 55791 7337 409 54
FPC 6 55675 2593 144 19
FPC 7 55608 7600 422 56
SCG/CB/SIB 55308 5600 309 25
For further description of the output from the commands, see show chassis environment pem .
Related
Documentation
•
T1600 Power System Description on page 113
Copyright © 2019, Juniper Networks, Inc.
Chapter 33: Maintaining Components
•
T1600 General Electrical Safety Guidelines on page 613
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Troubleshooting the T1600 Power System on page 552
•
T1600 Alarm Messages Overview on page 542
Maintaining the T1600 Routing Engines
Purpose For optimum router performance, verify the condition of the Routing Engines and the control boards.
Action On a regular basis:
• Check the LCD on the craft interface to view information about the router temperature and the status of the Routing Engines.
• Check the host subsystem LEDs on the craft interface. For more information about the
LEDs and the display, see
“T1600 Craft Interface Description” on page 33
. During normal operations:
• The green host subsystem OK LED on the craft interface is lit.
• The red host subsystem FAIL LED on the craft interface is not lit.
• Check the LEDs on the RE-2000 faceplate. During normal operations, the ONLINE LED is lit steadilygreen.
• Check the LEDs on the RE-C1800 faceplate. During normal operations, the ONLINE
LED is lit steadily green.
• Issue the show chassis routing-engine command to check the status of the Routing
Engines. The output is similar to the following: user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
Temperature 34 degrees C / 93 degrees F
DRAM 2048 Mbytes
CPU utilization:
User 0 percent
Background 0 percent
Kernel 1 percent
Interrupt 0 percent
Idle 99 percent
Start time 2002-01-22 05:21:31 UTC
Uptime 10 days, 16 hours, 4 minutes, 52 seconds
Load averages: 1 minute 5 minute 15 minute
0.00 0.00 0.00
Routing Engine status:
Slot 1:
Current state Empty
Copyright © 2019, Juniper Networks, Inc.
529
T1600 Core Router Hardware Guide
For further description of the output from the commands, see show chassis routing-engine .
Related
Documentation
•
T1600 Routing Engine Description on page 44
•
•
•
•
T1600 RE-C1800 LEDs on page 51
•
Troubleshooting the T1600 Host Subsystems on page 547
Maintaining the T1600 SCGs
Purpose For optimum router performance, verify the condition of the SCGs.
Action On a regular basis:
• Check the SCG LEDs. For more information, see
During normal operations:
• The green OK LED on the SCG faceplate is lit.
• The yellow FAIL LED on the SCG faceplate is not lit.
• Issue the show chassis environment scg command to display information about the
SCGs. The output is similar to the following: user@host> show chassis environment scg
SCG 0 status:
State Online - Master clock
Temperature 31 degrees C / 87 degrees F
Power:
GROUND 0 mV
3.3 V 3310 mV
5.0 V 5052 mV
5.6 V 5689 mV
1.8 V bias 1782 mV
3.3 V bias 3306 mV
5.0 V bias 4989 mV
8.0 V bias 8336 mV
GBUS Revision 40
FPGA Revision 1.6
For further description of the output from the commands, see show chassis environment scg .
Related
Documentation
•
Replacing a T1600 SCG on page 333
•
Removing a T1600 SCG on page 333
530 Copyright © 2019, Juniper Networks, Inc.
Chapter 33: Maintaining Components
Maintaining the T1600 SIBs
Purpose For optimum router performance, verify the condition of the SIBs.
Action On a regular basis:
• Observe the status of the SIBs by checking the LEDs on the SIB faceplate. During normal operations:
• The green OK LED on the SIB faceplate is lit.
• The yellow FAIL LED on the SIB faceplate is not lit.
• To check the status of the SIBs using the CLI, issue the show chassis environment sib command. The output is similar to the following: user@host> show chassis environment sib
SIB 0 status:
State Spare
Temperature 45 degrees C / 113 degrees F
Power:
GROUND 0 mV
1.8 V 1794 mV
2.5 V 2446 mV
3.3 V 3291 mV
1.8 V bias 1780 mV
3.3 V bias 3284 mV
5.0 V bias 5003 mV
8.0 V bias 6910 mV
SIB 1 status:
State Online
Temperature 45 degrees C / 113 degrees F
Power:
GROUND 0 mV
1.8 V 1802 mV
2.5 V 2461 mV
3.3 V 3294 mV
1.8 V bias 1782 mV
3.3 V bias 3294 mV
5.0 V bias 5013 mV
8.0 V bias 7057 mV
SIB 2 status:
State Online
Temperature 47 degrees C / 116 degrees F
Power:
GROUND 0 mV
1.8 V 1794 mV
2.5 V 2461 mV
3.3 V 3301 mV
1.8 V bias 1785 mV
3.3 V bias 3296 mV
5.0 V bias 4998 mV
8.0 V bias 7050 mV
For more information about using the command, see show chassis environment sib .
Copyright © 2019, Juniper Networks, Inc.
531
T1600 Core Router Hardware Guide
Related
Documentation
•
T1600 Switch Interface Board (SIB) Description on page 127
•
T1600 Craft Interface SIB LEDs on page 37
•
•
Replacing a T1600-SIB on page 479
Cleaning Fiber-Optic Array Components with the Dry Cloth Cleaning Tool
NOTE: This procedure is required only for TX Matrix Plus components and
T1600 routers in a routing matrix. It is not required for fiber-optic ports on the PICs.
As part of your routine maintenance, we recommend that you clean all exposed fiber-optic array components each time you disconnect and reconnect a fiber-optic array cable, or if the optical link is not functioning correctly.
NOTE: While you install the router or replace a fiber-optic array cable, small deposits of oil, dust, and debris can enter the fiber-optic array ports, the fiber-optic array cable connectors, and the loopback connectors and adapters used to test the optical connections. These deposits can cause loss of light, reducing signal power and causing intermittent problems with the optical connection.
The following tools for cleaning the fiber-optic components are provided in the TX Matrix
Plus tool kit:
• Dry cleaning tool (see
Figure 260 on page 532 ). This tool uses a dry cloth to remove
dust and oil from the fiber optics.
• Cleaning tool adapter
• Cleaning tool connector
Figure 260: Cleaning Tool
Cleaning tool
532 Copyright © 2019, Juniper Networks, Inc.
Chapter 33: Maintaining Components
To clean the fiber-optic components using the dry cloth cleaning tool:
1.
Take the TX Matrix Plus switching plane offline.
See the TX Matrix Plus Router Hardware Guide .
2.
Bring the TXP-F13 SIB offline by pressing the SFC ONLINE/OFFLINE button.
3.
Bring the TXP-T1600 SIB offline by pressing the ONLINE/OFFLINE button.
4.
Disconnect the fiber-optic array cable between the TXP-F13 SIB and TXP-T1600 SIB.
WARNING: Do not look directly into a fiber-optic array port or a connector at the end of a fiber-optic array cable connected to a port. The fiber optics emit laser light that can damage your eyes.
5.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
6.
Remove the dust cap from the fiber-optic array port. Open the dust shutter on the fiber-optic array port, and insert a cleaning adapter (see
).
7.
Remove the dust cap from the cleaning tool.
8.
Insert the tip of the dry cloth cleaning tool into the cleaning adapter (see
).
Copyright © 2019, Juniper Networks, Inc.
533
T1600 Core Router Hardware Guide
Figure 261: Inserting the Cleaning Adapter into the Fiber-Optic Array Port and the Cleaning
Tip into the Keyed Slot of the Cleaning Adapter
Fiber-Optic Array Connector
Cleaning tool adapter Cleaning tool
NOTE: This illustration shows TXP-F13 SIBs on a TX Matrix Plus router.
However, the method for inserting the cleaning tool adapter and cleaning tool is the same for the TXP-T1600 SIB.
NOTE: The cleaning adapter is keyed to ensure that the cleaning tip can be inserted in only one way.
9.
Rotate the thumb wheel in the direction indicated on the cleaning tool until the thumb wheel clicks to indicate a completed cleaning action (see
).
Figure 262: Rotating the Thumb Wheel
534 Copyright © 2019, Juniper Networks, Inc.
Chapter 33: Maintaining Components
10.
Clean the three visible ferrules in the fiber-optic array port.
11.
Repeat these steps for all fiber-optic components that require cleaning.
12.
Remove the dust cap from the fiber-optic array cable. Insert a cleaning connector into the fiber-optic array cable (see
). Insert the tip of the cleaning tool into the cleaning connector.
Figure 263: Inserting the Cleaning Connector into the Fiber-Optic Array Cable and the
Cleaning Tip into the Keyed Slot of the Cleaning Connector
Fiber-optic cable
Cleaning tool connector
Cleaning tool
13.
Replace the dust cap on the cleaning tool.
14.
After you clean the fiber-optic array ports and the fiber-optic array cable connectors, reconnect the fiber-optic array cable between the TXP-F13 SIB fiber-optic array port and TXP-T1600 SIB fiber-optic array port.
15.
Bring the TXP-F13 SIB and TXP-1600 SIB online.
16.
Issue the show chassis sibs command. Verify that the TXP-F13 SIB and TXP-T1600
SIB are online.
17.
Issue the show chassis fabric plane extensive command. Verify that the state of each optical link is Links ok .
18.
If the state of any TXP-F13 SIB, TXP-T1600 SIB, or link is still incorrect, contact your customer support representative for additional instructions.
Related
Documentation
•
T1600 Switch Interface Board (SIB) Description on page 127
•
TXP-T1600 SIB Description on page 129
Copyright © 2019, Juniper Networks, Inc.
535
T1600 Core Router Hardware Guide
536 Copyright © 2019, Juniper Networks, Inc.
PART 6
Troubleshooting Hardware
•
Troubleshooting Components on page 539
Copyright © 2019, Juniper Networks, Inc.
537
T1600 Core Router Hardware Guide
538 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 34
Troubleshooting Components
•
T1600 Troubleshooting Resources on page 539
•
T1600 LED Overview on page 540
•
T1600 Alarm Messages Overview on page 542
•
Troubleshooting the T1600 Cooling System on page 543
•
Troubleshooting the T1600 Craft Interface on page 546
•
Troubleshooting the T1600 Host Subsystems on page 547
•
Troubleshooting the T1600 Control Boards on page 548
•
Troubleshooting the T1600 Cooling System on page 549
•
Troubleshooting the T1600 FPCs on page 551
•
Troubleshooting the T1600 Power System on page 552
•
Troubleshooting the T1600 PICs on page 555
•
Troubleshooting the T1600 SCGs on page 556
•
Troubleshooting the T1600 SIBs on page 557
•
Testing a Fiber-Optic Array Switching Plane Port on page 559
•
Testing a Fiber-Optic Array Switching Plane Cable on page 561
T1600 Troubleshooting Resources
To troubleshoot a T1600 router, you use the Junos OS command-line interface (CLI),
LCD, alarms, devices connected to the alarm relay contacts on the CIP, and LEDs on both the components and craft interface.
• LEDs—When the Routing Engine detects an alarm condition, it lights the red or yellow alarm LED on the craft interface as appropriate. In addition, you can also use the component-specific LEDs on the craft interface and on the faceplate of a component to troubleshoot the routing matrix.
• LCD—When a red or yellow alarm occurs, the cause of the alarm messages is displayed on the craft interface LCD. Use the CLI to display more information about the alarm.
• Alarm devices connected to the alarm relay contact on the CIP—When a red or yellow alarm occurs, it trips the corresponding alarm relay contact on the CIP.
Copyright © 2019, Juniper Networks, Inc.
539
T1600 Core Router Hardware Guide
• CLI—The CLI is the primary tool for controlling and troubleshooting hardware, Junos
OS, routing protocols, and network connectivity. CLI commands display information from routing tables, information specific to routing protocols, and information about network connectivity derived from the ping and traceroute utilities.
For information about using the CLI to troubleshoot Junos OS, see the appropriate
Junos OS configuration guide.
• JTAC—If you need assistance during troubleshooting, you can contact the Juniper
Networks Technical Assistance Center (JTAC) by using the Web or by telephone. If you encounter software problems, or problems with hardware components not discussed here, contact JTAC.
Related
Documentation
•
Contacting Customer Support on page 565
•
T1600 Connector Interface Panel (CIP) Description on page 27
.
•
T1600 Alarm Messages Overview on page 542
•
T1600 Craft Interface Description on page 33
•
T1600 LED Overview on page 540
T1600 LED Overview
•
Craft Interface LED Overview on page 540
•
Component LED Overview on page 541
Craft Interface LED Overview
The craft interface displays system status messages and allows you to troubleshoot the
T1600 router. The craft interface is located on the upper front of the router. It contains
LEDs, buttons, and an LCD display showing status messages for the router.
LEDs on the craft interface include the following:
• Alarm LEDs—One large red circular LED and one large yellow triangular LED, located on the upper left of the craft interface, indicate two levels of alarm conditions. You can determine the cause of the alarm condition by looking at the LCD on the craft interface.
See
“T1600 Craft Interface Alarm LEDs and ACO/LT Button” on page 35
.
• Host subsystem LEDs—Three LEDs (one green MASTER , one green OK , and one red
FAIL ) indicate the status of each host subsystem. The host subsystem LEDs are located on the upper right of the craft interface, and are labeled HOST0 and HOST1 .
See
“T1600 Craft Interface Host Subsystem LEDs” on page 36 .
• SIB LEDs—Two LEDs (one red FAIL and one green OK ) indicate the status of each SIB.
The SIB LEDs are located on the upper right of the craft interface, and are labeled SIB0 through SIB4 .
540 Copyright © 2019, Juniper Networks, Inc.
Chapter 34: Troubleshooting Components
See
“T1600 Craft Interface SIB LEDs” on page 37 .
• FPC LEDs—Two LEDs (one red FAIL and one green OK ) indicate the status of each
FPC. The FPC LEDs are located along the bottom edge of the craft interface, and are labeled FPC0 through FPC7 .
See
“T1600 Craft Interface FPC LEDs” on page 37 .
Component LED Overview
The following LEDs are located on various router components and display the status of those components:
• Connector interface panel (CIP) LEDs—Two small LEDs on the left edge of the
ETHERNET port on the CIP indicate the connection in use.
NOTE: When RE-C1800 are installed, the LEDs are always yellow for both a 10-Mbps connection and 100-Mbps connection.
See
“T1600 Connector Interface Panel (CIP) LEDs” on page 29 .
• SIB LEDs—Three LEDs on each SIB faceplate— ACTIVE , OK , and FAIL —indicate the status of that SIB.
See
and
“TXP-T1600 SIB LEDs” on page 130 .
• T-CB LEDs—Three LEDs on each T-CB faceplate— ACTIVE , OK , and FAIL — indicate the status of that T-CB. If no LEDs are lit, the T-CB is not receiving power.
See
“T1600 T-CB LEDs” on page 76 .
• LCC-CB LEDs—Three LEDs on each LCC-CB faceplate— ACTIVE , OK , and FAIL — indicate the status of that LCC-CB. The ACT and LINK LEDs indicate the status of each port.
The JCS LINK port and LED are not currently supported. If no LEDs are lit, the LCC-CB is not receiving power.
See
“T1600 LCC-CB LEDs” on page 78 .
• SCG LEDs—Three LEDs on each SCG faceplate indicate the status of that SCG. If no
LEDs are lit, the SCG is not receiving power.
See
.
• PIC LEDs—Each port on each PIC has an LED that indicates the status of the port.
See the T1600 Core Router Interface Module Reference .
• Power supply LEDs—LEDs on each power supply faceplate indicate the status of that power supply.
See
“T1600 Three-Input 240-A DC Power Supply LEDs” on page 116 ,
240-A DC Power Supply LEDs” on page 118 ,
“T1600 Six-Input DC Power Supply LEDs” on page 121 , or
“T1600 Three-Phase Delta and Wye AC Power Supply LEDs” on page 124 .
Copyright © 2019, Juniper Networks, Inc.
541
T1600 Core Router Hardware Guide
T1600 Alarm Messages Overview
When the Routing Engine detects an alarm condition, it lights the red or yellow alarm
LED on the craft interface as appropriate, trips the corresponding alarm relay contact on the CIP, and reports the cause of the alarm in the craft interface LCD. To view a more detailed description of the alarm cause, issue the show chassis alarms CLI command: user@host> show chassis alarms
There are two classes of alarm messages:
• Chassis alarms indicate a problem with a chassis component such as the cooling system or power supplies.
Troubleshooting the T1600 SIBs on page 557
Troubleshooting the T1600 Host Subsystems on page 547
Troubleshooting the T1600 Control Boards on page 548
Troubleshooting the T1600 SCGs on page 556
Troubleshooting the T1600 Craft Interface on page 546
Troubleshooting the T1600 Cooling System on page 543
Troubleshooting the T1600 FPCs on page 551
Troubleshooting the T1600 PICs on page 555
Troubleshooting the T1600 Power System on page 552
• Interface alarms indicate a problem with a specific network interface, as described in
In
, the text in the column labeled “LCD Message” appears in the
LCD. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
Table 109: SONET/SDH Interface Alarm Messages
LCD Message CLI Message interface-name sox / x / x BERR-SD interface-name sox / x / x - SONET bit error rate defect interface-name sox / x / x BERR-SF interface-name sox / x / x LAIS interface-name sox / x / x LOF interface-name sox / x / x LOL interface-name sox / x / x LOP interface-name sox / x / x - SONET bit error rate fault interface-name sox / x / x - SONET line AIS interface-name sox / x / x - SONET loss of frame interface-name sox / x / x - SONET loss of light interface-name sox / x / x - SONET loss of pointer
542 Copyright © 2019, Juniper Networks, Inc.
Chapter 34: Troubleshooting Components
Table 109: SONET/SDH Interface Alarm Messages (continued)
LCD Message CLI Message interface-name sox / x / x LOS interface-name sox / x / x - SONET loss of signal interface-name sox / x / x LRDI interface-name sox / x / x PAIS interface-name sox / x / x PLL interface-name sox / x / x PMIS interface-name sox / x / x PRDI interface-name sox / x / x REI interface-name sox / x / x SEF interface-name sox / x / x UNEQ interface-name sox / x / x - SONET line remote defect indicator interface-name sox / x / x - SONET path AIS interface-name sox / x / x - SONET PLL lock interface-name sox / x / x - SONET path mismatch interface-name sox / x / x - SONET path remote defect indicator interface-name sox / x / x - SONET remote error indicator interface-name sox / x / x - SONET severely errored frame interface-name sox / x / x - SONET unequipped
Related
Documentation
•
Overview of Connecting the T1600 Router to External Devices on page 235
•
Routine Maintenance Procedures for the T1600 Router on page 507
•
T1600 Chassis Description on page 21
Troubleshooting the T1600 Cooling System
Problem Description:
The following alarms, LEDs, and other conditions indicate a problem with the cooling system:
• A red alarm indicates that temperature of the router exceeds the maximum
(“temperature hot”) threshold.
• Automatic shutdown of the power supplies was caused by the temperature of the router exceeding the maximum (“temperature hot”) threshold. The control board turns off the power supplies because the router temperature exceeds the acceptable maximum.
• A red alarm indicates that a fan failed.
• A yellow alarm indicates that the router temperature exceeds the “temperature warm” threshold.
Copyright © 2019, Juniper Networks, Inc.
543
T1600 Core Router Hardware Guide
• A yellow alarm indicates that one of the fan trays was removed.
• One or more fans in a fan tray function at full speed. The control boards constantly monitor the temperatures detected by sensors on the midplane and router components, adjusting the speed of the fans as necessary.
In
, the text in the column labeled ”LCD Message” appears in the display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
Table 110: T1600 Cooling System Alarms
Component
Alarm
Type LCD Message CLI Message Alarm Condition Solution
Fans Red Fan Failure fan-name Failure
Fans Missing Too many fans missing or failing
T1600 Rear Fan Tray in
LCC
T1600 Rear Fan
Tray in LCC
A fan has failed.
Replace the fan tray.
A fan tray is missing or too many fan trays have failed.
Reinstall the fan tray in the chassis.
For T1600 routers in a routing matrix, the rear fan tray part number 760-009870 is not supported.
Replace the rear fan tray with part number
760-024613 .
Yellow Fan Removed
Mix of FAN-TRAYS fan-name Removed A fan tray has been removed.
Minor – Mix of
FAN-TRAYS
A mix of standard front fan trays and quiet front fan trays are installed in the chassis.
NOTE: During normal operations, mixing the standard and quiet fan trays is not supported.
Reinstall the fan tray in the chassis.
Check that all fan trays are either standard fan trays or quiet fan trays. Install the correct fan trays.
NOTE: During an upgrade, ignore this alarm.
544 Copyright © 2019, Juniper Networks, Inc.
Chapter 34: Troubleshooting Components
Table 110: T1600 Cooling System Alarms (continued)
Component
Alarm
Type LCD Message CLI Message
Temperature sensors
Red Temperature Hot
Yellow
Sensor Failure
Temperature Warm
Alarm Condition Solution
Temperature Hot The chassis temperature exceeded the hot temperature threshold. If this condition persists, the router shuts down.
•
•
•
Verify that the room temperature is within acceptable limits.
Verify that there is sufficient air flow.
Verify that the cooling system in the chassis is operating properly.
Temperature sensor failure
A temperature sensor failed.
Contact JTAC.
Temperature Warm The chassis temperature exceeded the warm temperature threshold.
•
•
•
Verify that the room temperature is within acceptable limits.
Verify that there is sufficient air flow.
Verify that the cooling system in the chassis is operating properly.
Solution To troubleshoot the cooling system:
1.
Place your hand near the exhaust vents at the rear of the chassis to determine whether the fans are pushing air out of the chassis.
2.
If the red alarm LED on the craft interface lights, look at the craft interface display to find the source of the problem. The number of alarm conditions, as well as the source of each alarm, appears on the screen.
3.
If the craft interface display lists only one fan failure and the other fans are functioning normally, the fan is probably faulty and you need to replace the fan tray.
4.
Use the CLI to check the status of the fans. For example, you can issue the following command to get information about the source of an alarm condition: user@host> show chassis alarms
For information about the alarms, see
.
Copyright © 2019, Juniper Networks, Inc.
545
T1600 Core Router Hardware Guide
Related
Documentation
•
T1600 Cooling System Description on page 39
•
T1600 Chassis Description on page 21
•
Replacing the T1600 Standard Lower Front Fan Tray on page 337
•
Replacing the T1600 Standard Upper Front Fan Tray on page 339
•
Replacing the T1600 Rear Fan Tray on page 341
•
Replacing the T1600 Rear Air Filter on page 316
•
Replacing the T1600 Front Air Filter on page 313
Troubleshooting the T1600 Craft Interface
Problem Description:
The following alarms, LEDs, and other conditions indicate a problem with the craft interface:
• The router is powered on, but none of the LEDs on the craft interface are lit.
• A yellow alarm indicates that the craft interface has failed.
In
, the text in the column labeled ”LCD Message” appears in the display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
Table 111: T1600 Chassis Alarm Messages for the Craft Interface
Alarm Type LCD Message CLI Message
Yellow Craft Failure Craft Failure
Solution To troubleshoot the T1600 craft interface:
1.
Check the LEDs on the craft interface.
2.
Use the CLI to check for alarms.
• Standalone T1600 router—Issue the show chassis alarms command to view the alarms.
• T1600 router in a routing matrix—Issue the show chassis alarms lcc lcc-number command to view the alarms.
Related
Documentation
•
T1600 Craft Interface Description on page 33
•
T1600 Craft Interface Alarm LEDs and ACO/LT Button on page 35
546 Copyright © 2019, Juniper Networks, Inc.
Chapter 34: Troubleshooting Components
Troubleshooting the T1600 Host Subsystems
Problem Description:
The following alarms and LEDs indicate a problem with a host subsystem control board and Routing Engine:
• A red alarm indicates that the host subsystem has been removed.
• A yellow alarm indicates that the host subsystem has failed.
• The red host subsystem FAIL LED on the craft interface is lit.
• The green host subsystem OK LED on the craft interface is not lit.
In
Table 112 on page 547 , the text in the column labeled ”LCD Message” appears in the
display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
Table 112: T1600 Chassis Alarm Messages for Host Subsystems
Alarm Type LCD Message CLI Message
Red
Yellow
Host host-number Removed
Host host-number Failure
Host host-number Removed
Host host-number Failure
Solution To troubleshoot the host subsystems:
1.
Check the LEDs on the faceplate of each control board and Routing Engine.
2.
Check the LEDs on the craft interface.
3.
Use the CLI to check for alarms.
• Standalone T1600 router—Issue the show chassis alarms command to view the alarms.
• T1600 router in a routing matrix—Issue the show chassis alarms lcc lcc-number command to view the alarms.
Related
Documentation
•
T1600 Host Subsystem Description on page 43
•
T1600 Routing Engine Description on page 44
•
T1600 Control Boards Description on page 74
•
T1600 Craft Interface Host Subsystem LEDs on page 36
•
•
Copyright © 2019, Juniper Networks, Inc.
547
T1600 Core Router Hardware Guide
•
T1600 RE-C1800 LEDs on page 51
•
•
Troubleshooting the T1600 Control Boards
Problem Description:
The following alarms and LEDs indicate a problem with a control board:
• A red alarm indicates that the control board has failed or has been removed.
• A yellow alarm indicates that the Ethernet switch in the control board has failed.
• The yellow FAIL LED on the control board faceplate is lit.
• The green OK LED on the control board faceplate is not lit.
• The red host subsystem FAIL LED on the craft interface is lit.
• The green host subsystem OK LED on the craft interface is not lit.
In
, the text in the column labeled ”LCD Message” appears in the display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
Table 113: T1600 Chassis Alarm Messages for the Control Boards
Alarm Type LCD Message CLI Message
Red CB cb-number Removed CB cb-number Removed
Yellow
CB cb-number Failure CB cb-number Failure
CB cb-number Ethernet Switch Failure CB cb-number Ethernet Switch
Failure
Solution To troubleshoot the T1600 control boards:
1.
Check the LEDs on the faceplate of each control board.
2.
Check the LEDs on the craft interface.
3.
Use the CLI to check for alarms.
• Standalone T1600 router—Issue the show chassis alarms command to view the alarms.
• T1600 router in a routing matrix—Issue the show chassis alarms lcc lcc-number command to view the alarms.
548 Copyright © 2019, Juniper Networks, Inc.
Chapter 34: Troubleshooting Components
Related
Documentation
•
T1600 Host Subsystem Description on page 43
•
T1600 Control Boards Description on page 74
•
T1600 Craft Interface Host Subsystem LEDs on page 36
•
•
Troubleshooting the T1600 Cooling System
Problem Description:
The following alarms, LEDs, and other conditions indicate a problem with the cooling system:
• A red alarm indicates that temperature of the router exceeds the maximum
(“temperature hot”) threshold.
• Automatic shutdown of the power supplies was caused by the temperature of the router exceeding the maximum (“temperature hot”) threshold. The control board turns off the power supplies because the router temperature exceeds the acceptable maximum.
• A red alarm indicates that a fan failed.
• A yellow alarm indicates that the router temperature exceeds the “temperature warm” threshold.
• A yellow alarm indicates that one of the fan trays was removed.
• One or more fans in a fan tray function at full speed. The control boards constantly monitor the temperatures detected by sensors on the midplane and router components, adjusting the speed of the fans as necessary.
In
, the text in the column labeled ”LCD Message” appears in the display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
Copyright © 2019, Juniper Networks, Inc.
549
T1600 Core Router Hardware Guide
Table 114: T1600 Cooling System Alarms
Component
Alarm
Type LCD Message
Fans
Temperature sensors
Red
Yellow
Red
Yellow
Fan Failure
Fans Missing
CLI Message fan-name Failure
Too many fans missing or failing
T1600 Rear Fan Tray in
LCC
T1600 Rear Fan
Tray in LCC
Fan Removed
Mix of FAN-TRAYS
Temperature Hot
Sensor Failure
Temperature Warm
Alarm Condition Solution
A fan has failed.
Replace the fan tray.
A fan tray is missing or too many fan trays have failed.
Reinstall the fan tray in the chassis.
For T1600 routers in a routing matrix, the rear fan tray part number 760-009870 is not supported.
Replace the rear fan tray with part number
760-024613 .
fan-name Removed A fan tray has been removed.
Minor – Mix of
FAN-TRAYS
A mix of standard front fan trays and quiet front fan trays are installed in the chassis.
NOTE: During normal operations, mixing the standard and quiet fan trays is not supported.
Reinstall the fan tray in the chassis.
Check that all fan trays are either standard fan trays or quiet fan trays. Install the correct fan trays.
NOTE: During an upgrade, ignore this alarm.
Temperature Hot The chassis temperature exceeded the hot temperature threshold. If this condition persists, the router shuts down.
•
•
•
Verify that the room temperature is within acceptable limits.
Verify that there is sufficient air flow.
Verify that the cooling system in the chassis is operating properly.
Temperature sensor failure
A temperature sensor failed.
Contact JTAC.
Temperature Warm The chassis temperature exceeded the warm temperature threshold.
•
•
•
Verify that the room temperature is within acceptable limits.
Verify that there is sufficient air flow.
Verify that the cooling system in the chassis is operating properly.
550 Copyright © 2019, Juniper Networks, Inc.
Chapter 34: Troubleshooting Components
Solution To troubleshoot the cooling system:
1.
Place your hand near the exhaust vents at the rear of the chassis to determine whether the fans are pushing air out of the chassis.
2.
If the red alarm LED on the craft interface lights, look at the craft interface display to find the source of the problem. The number of alarm conditions, as well as the source of each alarm, appears on the screen.
3.
If the craft interface display lists only one fan failure and the other fans are functioning normally, the fan is probably faulty and you need to replace the fan tray.
4.
Use the CLI to check the status of the fans. For example, you can issue the following command to get information about the source of an alarm condition: user@host> show chassis alarms
For information about the alarms, see
.
Related
Documentation
•
T1600 Cooling System Description on page 39
•
T1600 Chassis Description on page 21
•
Replacing the T1600 Standard Lower Front Fan Tray on page 337
•
Replacing the T1600 Standard Upper Front Fan Tray on page 339
•
Replacing the T1600 Rear Fan Tray on page 341
•
Replacing the T1600 Rear Air Filter on page 316
•
Replacing the T1600 Front Air Filter on page 313
Troubleshooting the T1600 FPCs
Problem Description:
The following LEDs indicate a problem with an FPC:
• The red FAIL LED above the FPC is lit.
• The green OK LED above the FPC is not lit.
Copyright © 2019, Juniper Networks, Inc.
551
T1600 Core Router Hardware Guide
Solution To troubleshoot an FPC:
1.
Look at the display on the craft interface to check the status of the FPC and the PICs that are plugged into it.
2.
Verify that the FPC is properly seated in the midplane. Check that each ejector handle has been turned clockwise and is tight. Use a screwdriver to check that the screws inside the ejector handles are tight.
3.
Check the status of an FPC using the following CLI command: user@host> show chassis fpc
4.
Use the following option to display more detailed information: user@host> show chassis fpc detail
Related
Documentation
•
T1600 Flexible PIC Concentrator (FPC) Description on page 81
•
T1600 Craft Interface FPC LEDs on page 37
•
Maintaining T1600 FPCs on page 514
•
Replacing a T1600 FPC on page 395
Troubleshooting the T1600 Power System
Problem Description:
The following alarms, LEDs, and other conditions indicate a problem with the power system:
• If all power supplies have failed, the system temperature might have exceeded the threshold, causing the system to shut down.
• The blue DC OK LED blinks when a power supply detects a fault (the power supply fails, does not have sufficient airflow, is going through a startup test, or is not properly inserted).
• The yellow OVER TEMP LED lights when a power supply is not receiving enough airflow to maintain proper temperature.
• The green AC OK LED is off when an AC power supply is not receiving voltage.
In
, the text in the column labeled ”LCD Message” appears in the display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
552 Copyright © 2019, Juniper Networks, Inc.
Chapter 34: Troubleshooting Components
Table 115: Power System Chassis Alarms
Alarm Type LCD Message
Red
Yellow
PEM pem-number Over Temp
PEM pem-number Output Fail
PEM pem-number Input Fail
PEM pem-number Removed
PEM pem-number Inputs Cfg
CLI Message
PEM pem-number Over Temperature
PEM pem-number Output Failure
PEM pem-number Input Failure
PEM pem-number Removed
PEM pem-number Configuration
Mismatch-number of inputs
Solution 1.
Check the LEDs on each three-input 240-A DC or four-input 240-A DC power supply faceplate.
• DC OK power supply LED is blinking—Check the red alarm LED on the craft interface.
• DC OK power supply LED is off and no red alarm condition exists—Check that the circuit breakers are switched to the ON position ( | ).
• DC OK LED on one or both of the power supplies is not lit—Check the power supply fans to see if they are operating.
• OVER TEMP LED on one of the power supplies lights—Check the fans and air filters to be sure they are functioning and providing sufficient airflow through the chassis.
2.
Check the LEDs on each six-input DC power supply faceplate.
• The DC OK LED on one or both of the power supplies is not lit—Check that the power switch is on.
• The OVER TEMP LED on one of the power supplies is lit—Check the fan trays and air filters to be sure they are functioning and providing sufficient airflow through the chassis.
• An INPUT PRESENT LED on a DC power supply is not lit—Check that the input is receiving source DC power.
3.
Check the LEDs on each three-phase delta or wye power supply faceplate.
• AC OK power supply LED is off—Check that the power supply is receiving voltage.
• DC OK power supply LED is blinking—Check the red alarm LED on the craft interface.
• DC OK LED on one or both of the power supplies is not lit—Check the power supply fans to see if they are operating.
• OVER TEMP LED on one of the power supplies lights—Check the fans and air filters to be sure they are functioning and providing sufficient airflow through the chassis.
Copyright © 2019, Juniper Networks, Inc.
553
T1600 Core Router Hardware Guide
554
4.
Check the display on the craft interface to determine the source of a yellow or red alarm (see
). Junos OS constantly updates the screen with status information for each component.
NOTE: On the display and in the CLI, the power supplies are referred to as PEM0 and PEM0 , from top to bottom.
If the system temperature exceeds the threshold, Junos OS shuts down all power supplies so that no status is displayed.
Junos OS also can shut down one of the power supplies for other reasons.
In that case, the remaining power supply assumes the load, and you can still view the system status through the CLI or display.
5.
Verify that the source circuit breaker has the proper current rating.
NOTE: All inputs on a DC power supply in slot PEM0 must be powered by dedicated power feeds derived from feed A, and all inputs on a DC power supply in slot PEM 1 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed A/B feed redundancy for the system.
NOTE: The AC power cord on an AC power supply in slot PEM0 must be powered by a dedicated power feed derived from feed A, and The AC power cord on an AC power supply in slot PEM 1 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed A/B feed redundancy for the system.
6.
Verify that the DC power cables or AC power cord from the power source to the router are not damaged. If the insulation is cracked or broken, immediately replace the DC power cable or AC power cord.
7.
Connect the power supply to a different power source with a new DC power cable or
AC power cord. If the power supply DC OK LED still does not light, the power supply is the source of the problem. Replace the power supply with a spare.
DC OK LED on the installed spare does not light—the replaced power supply might be faulty. To return it for replacement, see
“Contacting Customer Support” on page 565
.
8.
If you cannot determine the cause of the problem or need additional assistance, see
“Contacting Customer Support” on page 565
.
Copyright © 2019, Juniper Networks, Inc.
Chapter 34: Troubleshooting Components
Related
Documentation
•
T1600 Craft Interface Description on page 33 .
•
Replacing a T1600 Three-Input 240-A DC Power Supply on page 414
•
Replacing a T1600 Four-Input 240-A DC Power Supply on page 425
•
•
Replacing a T1600 Six-Input DC Power Supply on page 440
•
Replacing a T1600 DC Power Supply Cable on a Six-Input DC Power Supply on page 446
•
Replacing a T1600 Three-Phase Delta AC Power Supply on page 451
•
Replacing a T1600 Three-Phase Delta AC Power Supply Cord on page 459
•
Replacing a T1600 Three-Phase Wye AC Power Supply on page 465
•
Replacing a T1600 Three-Phase Wye AC Power Supply Cord on page 472
Troubleshooting the T1600 PICs
Problem Description: A PIC LED lit red indicates a problem with the PIC.
Solution To troubleshoot a PIC:
1.
Check the status of each port on a PIC. Look at the LEDs located on the PIC faceplate.
For information about the meaning of LED states on different PICs, see the T1600
Core Router Interface Module Reference .
2.
Check the status of a PIC, issuing the following CLI command. The PIC slots in the
FPC are numbered from 0 through 3 , top to bottom: user@host> show chassis fpc pic-status
Slot 0 Online E-FPC Type 3
PIC 0 Online 1x 10GE(LAN),DWDM
PIC 2 Present 1x OC-192 SONET XFP- Hardware Error
PIC 3 Online 1x 10GE(LAN),XENPAK
Slot 2 Online E2-FPC Type 2
PIC 0 Online 1x OC-48 SONET, SMIR
PIC 1 Online 2x OC-12 ATM-II IQ, MM
PIC 2 Online 8x 1GE(LAN), IQ2
Slot 3 Online FPC Type 3
PIC 0 Online 1x 10GE(LAN),XENPAK
PIC 1 Online 1x 10GE(LAN),XENPAK
PIC 2 Online 8x 1GE(TYPE3), IQ2
PIC 3 Online 8x 1GE(TYPE3), IQ2
Slot 4 Online FPC Type 4
PIC 0 Online 4x OC-192 SONET XFP
Slot 6 Online FPC Type 3
PIC 0 Online 4x OC-48 SONET
PIC 1 Online 1x Tunnel
Slot 7 Online FPC Type 4
PIC 0 Online 1x OC-768 SONET SR
Copyright © 2019, Juniper Networks, Inc.
555
T1600 Core Router Hardware Guide
For further description of the output from the command, see show chassis fpc .
Related
Documentation
•
T1600 PIC Description on page 94
•
Maintaining T1600 PICs and PIC Cables on page 523
Troubleshooting the T1600 SCGs
Problem Description:
The following alarms and LEDs indicate a problem with an SCG:
• A red alarm indicates that the SCG has failed or has been removed.
• A yellow alarm indicates that the SCG is not online.
• The yellow FAIL LED on the SCG faceplate is lit.
• The green OK LED on the SCG faceplate is not lit.
In
Table 116 on page 556 , the text in the column labeled ”LCD Message” appears in the
display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
Table 116: Chassis Alarm Messages for the SCGs
Alarm Type LCD Message CLI Message
Red
Yellow
SCG SCG-number
Failure
SCG SCG-number
Removed
SCG
SCG
SCG-number Failure
SCG-number Removed
SCG SCG-number Not
Online
SCG SCG-number Not Online
Solution To troubleshoot the T1600 SCGs:
1.
Check the LEDs on the faceplate of each SCG.
2.
Check the LEDs on the craft interface.
3.
Use the CLI to check for alarms.
• Standalone T1600 router—Issue the show chassis alarms command to view the alarms.
• T1600 router in a routing matrix—Issue the show chassis alarms lcc lcc-number command to view the alarms.
556 Copyright © 2019, Juniper Networks, Inc.
Chapter 34: Troubleshooting Components
Related
Documentation
•
T1600 SONET Clock Generators Description on page 30
•
Troubleshooting the T1600 SIBs
Problem Description:
The following alarms and LEDs indicate a problem with a SIB:
• A red alarm indicates that the SIB failed or has been removed.
• A yellow alarm indicates that a spare SIB has failed or has been removed.
• The yellow FAIL LED on the SIB faceplate is lit.
• The green OK LED on the SIB faceplate is not lit.
In
and
, the text in the column labeled ”LCD
Message” appears in the display of the craft interface. The text in the column labeled
“CLI Message” appears in the output from the show chassis alarms command.
Table 117: T1600 Chassis Alarm Messages for SIBs
Alarm Type LCD Message CLI Message Alarm Condition Solution
Red Replace the SIB.
SIB sib-number Failure SIB sib-number Fault
SIB sib-number
Removed
A SIB on an active switching plane has failed.
SIB sib-number Absent A SIB on an active switching plane has been removed.
Reinstall the SIB in the chassis.
Yellow Spare SIB Failure
Spare SIB Removed
Check SIB
Spare SIB Fault
Spare SIB Absent
Check SIB
A SIB on a backup switching plane has failed.
A SIB on a backup switching plane has been removed.
Replace the SIB.
Reinstall the SIB in the chassis.
SIB is not inserted properly, destination errors are detected on the SIB, or link errors are detected on the channel between the SIB and a
Packet Forwarding
Engine in an FPC.
Check that the SIB is correctly installed.
For destination errors, use the show chassis fabric fpcs command and show chassis fabric sibs command for more details.
Solution To troubleshoot the T1600 SIBs:
1.
Check the LEDs on the faceplate of each SIB.
Copyright © 2019, Juniper Networks, Inc.
557
T1600 Core Router Hardware Guide
2.
Check the LEDs on the craft interface.
3.
Use the CLI to check for alarms.
• Standalone T1600 router—Issue the show chassis alarms command to view the alarms.
• T1600 router in a routing matrix—Issue the show chassis alarms lcc lcc-number command to view the alarms.
Table 118: Chassis Alarm Messages for a T1600 Router in a Routing Matrix
Alarm Type
Craft Interface
LCD Message CLI Message Alarm Condition Solution
Red ST_SIB_L sib-number :VCSEL
Fault
ST_SIB_L sib-number : SIB
VCSEL Fault
Loss of signal
(LOS) has occurred in a vertical-cavity surface-emitting laser (VCSEL) in a TXP-T1600
SIB.
Replace the
TXP-T1600 SIB on the T1600 router.
SIB sib-number
FPC Links
SIB sib-number
FPC Link Error
The TXP-T1600
SIB has detected
Link errors on
FPC-SIB links.
To isolate the problem:
1.
Replace the
TXP-T1600 SIB.
2. If the problem persists, replace each FPC.
3. If you are unable to isolate the problem, contact
JTAC.
Related
Documentation
•
T1600 Craft Interface SIB LEDs on page 37
•
T1600-SIB Description on page 128
•
TXP-T1600 SIB Description on page 129
•
•
TXP-T1600 SIB LEDs on page 130
•
Replacing a T1600-SIB on page 479
•
Replacing a TXP-T1600 SIB on page 482
558 Copyright © 2019, Juniper Networks, Inc.
Chapter 34: Troubleshooting Components
Testing a Fiber-Optic Array Switching Plane Port
Four fiber-optic array loopback connectors are shipped in the tool kit with the TX Matrix
Plus router (see
).
NOTE: Use the loopback connectors to test the TXP-F13 ports.
Figure 264: TX Matrix Plus Fiber-Optic Array Switching Plane Loopback Connector and
Loopback Adapter
Loopback adapter Loopback connector
CAUTION: Do not connect and disconnect the fiber-optic array switching plane cable connectors, loopback connectors, or loopback adapters more frequently than required to perform the procedures in this hardware guide.
These fiber-optic components are rated for a limited number of insertions
(approximately 100).
To use the loopback connectors to test the TXP-F13 SIB fiber-optic array switching plane ports:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Take the switching plane offline.
See Taking a Switching Data Plane Offline in the TX Matrix Plus Router Hardware Guide .
3.
Bring the TXP-F13 SIB offline by pressing the SFC ONLINE/OFFLINE button.
4.
Remove the dust covers from the loopback connectors and from the fiber-optic array switching plane ports. Temporarily store the dust covers in a dust-free resealable plastic bag.
Copyright © 2019, Juniper Networks, Inc.
559
T1600 Core Router Hardware Guide
CAUTION: During maintenance or replacement procedures, small deposits of oil, dust, and debris can enter the TXP-F13 SIB and TXP-T1600 SIB fiber-optic array switching plane ports, the fiber-optic array switching plane cable connectors, and the loopback connectors and adapters.
5.
Align a loopback connector with each TXP-F13 SIB fiber-optic array switching plane port, and carefully press it into the port until it stops. The loopback connector and fiber-optic array switching plane port are keyed to ensure proper mating.
6.
Bring the TXP-F13 SIB online by pressing the SFC ONLINE/OFFLINE button.
7.
Verify that the RxPWR LED for that fiber-optic array switching plane port is steadily lit green.
8.
If the RxPWR LED for any fiber-optic array switching plane port is lit steadily yellow or is not lit , take the TXP-F13 SIB offline again, remove the loopback connector, and clean the fiber-optic array switching plane ports and loopback connectors. Then reconnect the loopback connectors.
If the RxPWR LEDs for the fiber-optic array switching plane ports still fail to light steadily green, contact your customer support representative for additional instructions.
9.
After you have finished testing the fiber-optic array switching plane port, remove a dust cover from the dust-free resealable plastic bag. To reinstall the dust cover on the loopback connector, align the dust cover with the loopback connector, and carefully press them together until they stop. The covers and the loopback connectors are keyed to ensure proper mating. Store the loopback connectors in the dust-free resealable plastic bag.
Related
Documentation
• Troubleshooting Switching Plane Connections to TX Matrix Plus TXP-F13 SIBs
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Cleaning Fiber-Optic Array Components with the Dry Cloth Cleaning Tool on page 532
560 Copyright © 2019, Juniper Networks, Inc.
Chapter 34: Troubleshooting Components
Testing a Fiber-Optic Array Switching Plane Cable
Use a fiber-optic array loopback adapter (see
Figure 265 on page 562 ) that is shipped in
the TX Matrix Plus tool kit to test the integrity of the fiber-optic array cables.
To test a fiber-optic array cable:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Remove the dust cover from the loopback adapter and the fiber-optic array cable.
Store the dust covers in a dust-free resealable plastic bag.
3.
Take the switching plane offline.
See Taking a Switching Data Plane Offline in the TX Matrix Plus Router Hardware Guide .
4.
Bring the TXP-F13 SIB offline by pressing the ONLINE/OFFLINE button for the SFC.
WARNING: Do not look directly into a fiber-optic array switching plane port or a connector at the end of a fiber-optic array switching plane cable connected to a port. The optics emit laser light that can damage your eyes.
5.
Disconnect the fiber-optic array switching plane cable from the port.
6.
Install a dust cover on the fiber-optic array switching plane port.
7.
Clean the fiber-optic array switching plane cable and loopback adapter.
CAUTION: During maintenance or replacement procedures, small deposits of oil, dust, and debris can enter the TXP-F13 SIB and TXP-T1600 SIB fiber-optic array switching plane ports, fiber-optic array switching plane cable connectors, and loopback connectors and adapters. We recommend that you clean the optics in these components immediately before connecting them.
8.
Align the loopback adapter with the cable connector, and carefully press it into the connector until it stops. The loopback adapter and the cable connector are keyed to ensure proper mating.
9.
Bring the TXP-F13 SIB online by pressing the ONLINE/OFFLINE button for the SFC.
Copyright © 2019, Juniper Networks, Inc.
561
T1600 Core Router Hardware Guide
WARNING: Do not look directly into a fiber-optic array switching plane port or a connector at the end of a fiber-optic array switching plane cable connected to a port. The fiber optics emit laser light that can damage your eyes.
10.
Verify that the RxPWR LED for the fiber-optic array switching plane port is steadily lit green.
11.
If the RxPWR LED for a fiber-optic array switching plane port is lit steadily yellow or is not lit, bring the TXP-F13 SIB offline, remove the loopback adapter, and clean it and the fiber-optic array cable. After you have cleaned the fiber-optic array switching plane cable and the loopback adapter, repeat the procedure. If the RxPWR LED for a fiber-optic array switching plane port still does not steadily light green, contact your customer support representative for additional instructions. Do not proceed with the installation of the TX Matrix Plus router until you have spoken to your customer support representative.
12.
Remove a dust cover from the dust-free resealable plastic bag and reinstall it on the loopback adapter. Align the dust cover with the loopback adapter, and carefully press them together until they stop. The cover and the loopback adapter are keyed to ensure proper mating. Store the loopback adapter in the dust-free resealable plastic bag.
Figure 265: Fiber-Optic Array Switching Plane Loopback Connector and Loopback Adapter
Loopback adapter Loopback connector
562
Related
Documentation
• Troubleshooting Switching Plane Connections to TX Matrix Plus TXP-F13 SIBs
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Cleaning Fiber-Optic Array Components with the Dry Cloth Cleaning Tool on page 532
Copyright © 2019, Juniper Networks, Inc.
PART 7
Contacting Customer Support and
Returning the Chassis or Components
•
Contacting Customer Support on page 565
•
Locating Component Serial Numbers on page 567
•
Packing and Returning Components on page 577
Copyright © 2019, Juniper Networks, Inc.
563
T1600 Core Router Hardware Guide
564 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 35
Contacting Customer Support
•
Contacting Customer Support on page 565
Contacting Customer Support
You can contact Juniper Networks Technical Assistance Center (JTAC) 24 hours a day,
7 days a week in one of the following ways:
• On the Web, using the Case Manager link at: https://www.juniper.net/support/
• By telephone:
From the US and Canada: 1-888-314-JTAC
From all other locations: 1-408-745-9500
If contacting JTAC by phone, enter your 12-digit case number followed by the # key if this is an existing case, or press the * key to be routed to the next available support engineer.
When requesting support from JTAC by telephone, be prepared to provide the following information:
• Your existing case number, if you have one
• Details of the failure or problem
• Type of activity being performed on the platform when the problem occurred
• Configuration data using one or more of the show commands
Copyright © 2019, Juniper Networks, Inc.
565
T1600 Core Router Hardware Guide
566 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 36
Locating Component Serial Numbers
•
Locating T1600 Component Serial Numbers Using the CLI on page 567
•
T1600 Component Serial Number Label Locations on page 569
Locating T1600 Component Serial Numbers Using the CLI
Before contacting Juniper Networks, Inc. to request a Return Materials Authorization
(RMA), you must find the serial number on the router or component. To list all of the router components and their serial numbers, enter the following command-line interface
(CLI) command: user@host> show chassis hardware
Hardware inventory:
Item Version Part number Serial number Description
Chassis JN1090E3BAHA T1600
Midplane REV 02 710-002726 RC0093 T-series Backplane
FPM GBUS REV 10 710-002901 DA3629 T640 FPM Board
FPM Display REV 05 710-021387 DE3389 T1600 FPM Display
CIP REV 06 710-002895 DC7064 T-series CIP
PEM 0 Rev 06 740-017906 TE27796 Power Entry Module 3x80
SCG 0 REV 14 710-003423 DC8262 T640 Sonet Clock Gen.
SCG 1 REV 14 710-003423 DC8259 T640 Sonet Clock Gen.
Routing Engine 0 REV 06 740-014082 1000686603 RE-A-2000
Routing Engine 1 REV 03 740-014082 1000621181 RE-A-2000
CB 0 REV 15 710-002728 HS4099 T-series Control Board
CB 1 REV 16 710-002728 JG0297 T-series Control Board
FPC 0 REV 11 710-010154 JH6612 E-FPC Type 3
CPU REV 06 710-010169 JG3054 FPC CPU-Enhanced
PIC 0 REV 09 750-012158 JR3386 1x 10GE(LAN),DWDM
PIC 2 REV 08 750-015749 WJ9160 1x OC-192 SONET XFP
PIC 3 REV 11 750-009567 CW9479 1x 10GE(LAN),XENPAK
Xcvr 0 NON-JNPR UNKNOWN
MMB 0 REV 04 710-010171 JH6572 MMB-5M3-288mbit
MMB 1 REV 04 710-010171 JH6574 MMB-5M3-288mbit
FPC 2 REV 04 710-013558 JS8712 E2-FPC Type 2
CPU REV 02 710-013563 JS6763 FPC CPU-Enhanced
PIC 0 REV 03 750-001900 AD5698 1x OC-48 SONET, SMIR
PIC 1 REV 12 750-007219 NB0328 2x OC-12 ATM-II IQ, MM
PIC 2 REV 07 750-011800 JR9100 8x 1GE(LAN), IQ2
Xcvr 0 REV 01 740-011782 PB81Z4K SFP-SX
MMB 1 REV 05 710-010171 JJ9426 MMB-5M3-288mbit
FPC 3 REV 07 710-007529 HS5608 FPC Type 3
CPU REV 15 710-001726 HX4351 FPC CPU
Copyright © 2019, Juniper Networks, Inc.
567
T1600 Core Router Hardware Guide
PIC 0 REV 12 750-009567 WE5415 1x 10GE(LAN),XENPAK
Xcvr 0 REV 02 740-013170 T07D15262 XENPAK-LR
PIC 1 REV 09 750-009567 NH3937 1x 10GE(LAN),XENPAK
Xcvr 0 REV 02 740-013170 T06F90365 XENPAK-LR
PIC 2 REV 05 750-015217 DA2065 8x 1GE(TYPE3), IQ2
Xcvr 0 REV 01 740-013111 6010717 SFP-T
Xcvr 1 REV 01 740-013111 61161012 SFP-T
Xcvr 2 REV 01 740-011613 P9F11CX SFP-SX
Xcvr 3 REV 01 740-011782 PB758WT SFP-SX
Xcvr 4 REV 01 740-011782 PB81NA0 SFP-SX
Xcvr 6 REV 01 740-011782 P9M18ZJ SFP-SX
Xcvr 7 NON-JNPR H11SDJQ SFP-LX10
PIC 3 REV 05 750-015217 WF8382 8x 1GE(TYPE3), IQ2
Xcvr 0 REV 01 740-011613 PBG3XTJ SFP-SX
Xcvr 1 REV 01 740-011613 P9F11XC SFP-SX
Xcvr 2 REV 01 740-011782 PB81NFN SFP-SX
Xcvr 3 REV 01 740-011782 PB81X89 SFP-SX
Xcvr 7 REV 01 740-011613 P9F15C3 SFP-SX
MMB 0 REV 03 710-005555 HZ1907 MMB-288mbit
MMB 1 REV 03 710-005555 HW5283 MMB-288mbit
PPB 0 REV 04 710-002845 HZ7717 PPB Type 3
PPB 1 REV 04 710-002845 HS0110 PPB Type 3
FPC 4 REV 02 710-010845 JE2392 FPC Type 4
CPU REV 02 710-011481 JF6820 FPC CPU-Enhanced
PIC 0 REV 06 750-012518 HY7858 4x OC-192 SONET XFP
Xcvr 0 REV 01 740-014279 AA0716N10CK XFP-OC192-SR
Xcvr 1 NON-JNPR T06D74999 XFP-OC192-SR
Xcvr 2 REV 01 740-014279 62E204N00007 XFP-OC192-SR
Xcvr 3 REV 01 740-014279 62E204N00005 XFP-OC192-SR
MMB 0 REV 03 710-010842 HY7601 ST-MMB
FPC 6 REV 12 710-007529 HV8510 FPC Type 3
CPU REV 15 710-001726 HW4494 FPC CPU
PIC 0 REV 11 750-009553 NF3180 4x OC-48 SONET
Xcvr 0 REV 01 740-011613 PAM2YA3 UNKNOWN
PIC 1 REV 05 750-004695 HT4383 1x Tunnel
MMB 0 REV 03 710-005555 HW8956 MMB-288mbit
MMB 1 REV 03 710-005555 HV6207 MMB-288mbit
PPB 0 REV 04 710-002845 HY0663 PPB Type 3
PPB 1 REV 04 710-002845 HY0662 PPB Type 3
FPC 7 REV 08 710-010845 JT5237 FPC Type 4
CPU REV 04 710-011481 JX1251 FPC CPU-Enhanced
PIC 0 REV 01 750-010850 JA0317 1x OC-768 SONET SR
MMB 0 REV 04 710-010842 JX4560 ST-MMB
SPMB 0 REV 09 710-003229 HZ3901 T-series Switch CPU
SPMB 1 REV 10 710-003229 JG5876 T-series Switch CPU
SIB 0 REV 05 710-013074 DB2654 SIB-I8-SF
SIB 1 REV 05 710-013074 DE7924 SIB-I8-SF
SIB 2 REV 05 710-013074 DE9221 SIB-I8-SF
SIB 3 REV 05 710-013074 DB2597 SIB-I8-SF
SIB 4 REV 05 710-013074 DE8335 SIB-I8-SF
Fan Tray 0 Front Top Fan Tray
Fan Tray 1 Front Bottom Fan Tray
Fan Tray 2 Rear Fan Tray
Most components also have a small rectangular serial number ID label (see
) attached to the component body.
568 Copyright © 2019, Juniper Networks, Inc.
Chapter 36: Locating Component Serial Numbers
Figure 266: Serial Number ID Label
Related
Documentation
•
T1600 Router Description on page 3
•
Contacting Customer Support on page 565
•
Returning a Hardware Component to Juniper Networks, Inc. on page 580
T1600 Component Serial Number Label Locations
•
Control Board Serial Number Label on page 569
•
CIP Serial Number Label on page 570
•
Craft Interface Serial Number Label on page 570
•
FPC Serial Number Label on page 571
•
PIC Serial Number Label on page 572
•
Power Supply Serial Number Label on page 573
•
Routing Engine Serial Number Label on page 574
•
SCG Serial Number Label on page 574
•
SIB Serial Number Label on page 575
Control Board Serial Number Label
The location of the serial number label varies depending on the control board. The T-CB serial number is located on the top of the control board (see
Figure 267: T-CB Serial Number Label
The LCC-CB serial number is located on the lower right side of the control board (see
).
Copyright © 2019, Juniper Networks, Inc.
569
T1600 Core Router Hardware Guide
Figure 268: LCC-CB Serial Number Label
CIP Serial Number Label
The serial number label is located at the top of the left side of the CIP (see
Figure 269: CIP Serial Number Label
Craft Interface Serial Number Label
The serial number is located on the back of the craft interface panel, behind the alarm
LEDs (see
).
570 Copyright © 2019, Juniper Networks, Inc.
Chapter 36: Locating Component Serial Numbers
Figure 270: Craft Interface Serial Number Label
FPC Serial Number Label
The location of the serial number label varies depending on the FPC:
• Type 1 FPCs: located near the top PIC slot
• Type 2 FPCs: located near the top PIC slot
• Type 3 FPCs: located center of the right side
• T640 Type 4 FPCs: located center left near the top of the FPC
• T1600 Type 4 FPCs: located lower right side
For example,
shows the serial number location for a T1600 Type
4 FPC.
Copyright © 2019, Juniper Networks, Inc.
571
T1600 Core Router Hardware Guide
Figure 271: Serial Number Label on a T1600 Type 4 FPC
PIC Serial Number Label
The exact location serial number label is different on different PICs, depending on the placement of components on the PIC board. In this example, the serial number label is located on the right side of the PIC (see
Figure 272 on page 573 ), when the PIC is vertically
oriented (as it would be installed in the router).
572 Copyright © 2019, Juniper Networks, Inc.
Figure 272: PIC Serial Number Label
Chapter 36: Locating Component Serial Numbers
Power Supply Serial Number Label
For the three-input 240-A DC power supply, the serial number label is located on the left side of the power supply faceplate (see
).
Figure 273: Three-input 240-A Power Supply Serial Number Label
For the six-input DC power supply, the serial number label is located on the lower left side of the faceplate. (see
Copyright © 2019, Juniper Networks, Inc.
573
T1600 Core Router Hardware Guide
Figure 274: DC Power Supply Serial Number Label
Serial number ID label
Routing Engine Serial Number Label
The serial number label is located on the right side of the top of the Routing Engine (see
).
Figure 275: Routing Engine Serial Number Label
SCG Serial Number Label
The serial number is located on the top of the SCG, close to the midplane connector (see
574 Copyright © 2019, Juniper Networks, Inc.
Figure 276: SCG Serial Number Label
Chapter 36: Locating Component Serial Numbers
SIB Serial Number Label
For the standard SIB or SIB version B, the serial number label is located as shown in
Figure 277: Standard SIB and SIB Version B Serial Number Label
For the TXP-LCC-3D SIB, the serial number label is located as shown in
Copyright © 2019, Juniper Networks, Inc.
575
T1600 Core Router Hardware Guide
Figure 278: TXP-LCC-3D Serial Number Label
Serial number ID label
Related
Documentation
•
T1600 Hardware Component Overview on page 17
•
Locating T1600 Component Serial Numbers Using the CLI on page 567
576 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 37
Packing and Returning Components
•
Tools and Parts Required to Remove Components from a T1600 Router on page 577
•
Packing the T1600 Router for Shipment on page 578
•
Packing the T1600 Router Components for Shipment on page 579
•
Returning a Hardware Component to Juniper Networks, Inc. on page 580
Tools and Parts Required to Remove Components from a T1600 Router
To remove components from the router or the router from a rack, you need the following tools and parts:
• 2.5-mm flat-blade (–) screwdriver, for detaching alarm relay terminal block
• 7/16-in. (11 mm) nut driver
• Blank panels to cover empty slots
• Electrostatic bag or antistatic mat, for each component
• Electrostatic discharge (ESD) grounding wrist strap
• Flat-blade (–) screwdriver
• Mechanical lift, if available
• Phillips (+) screwdrivers, numbers 1 and 2
• Rubber safety cap for fiber-optic interfaces or cable
• Wire cutters
Related
Documentation
•
Tools and Parts Required for Replacing T1600 Hardware Components on page 310
•
Packing the T1600 Router for Shipment on page 578
•
Packing the T1600 Router Components for Shipment on page 579
•
Contacting Customer Support on page 565
Copyright © 2019, Juniper Networks, Inc.
577
T1600 Core Router Hardware Guide
Packing the T1600 Router for Shipment
To pack the router for shipment:
1.
Retrieve the shipping crate and packing materials in which the router was originally shipped. If you do not have these materials, contact your Juniper Networks representative about approved packaging materials.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
On the console or other management device connected to the master Routing Engine, enter CLI operational mode. To shut down the router software: user@host> request system halt
(If two Routing Engines are installed, also issue the command on the backup Routing
Engine.) Wait until a message appears on the console confirming that the operating system has halted.
The command shuts down the Routing Engine cleanly, so its state information is preserved. For more information about the command, see request system halt .
NOTE: The SIB might continue forwarding traffic for approximately 5 minutes after the request system halt command has been issued.
4.
For all power supplies, shut down power to the router by pressing the circuit breakers to the off ( O ) position, or the power switch to the standby position.
5.
Disconnect power from the router. For instructions, see:
•
Removing a T1600 DC Power Supply Cable From a Three-Input 240-A DC Power
Supply or Four-Input 240-A DC Power Supply on page 432
•
Removing a T1600 Three-Phase Delta AC Power Supply Cord on page 460
•
Removing a T1600 Three-Phase Wye AC Power Supply Cord on page 472
6.
Remove the cables that connect to all external devices. For instructions, see
“Replacing a T1600 Console or Auxiliary Cable” on page 323 ,
“Replacing the T1600 Alarm Relay Wires” on page 320 ,
and
“Replacing a T1600 PIC Cable” on page 408
.
7.
Remove all Field Replaceable Units (FRUs) from the router.
8.
Remove the router from the rack:
578 Copyright © 2019, Juniper Networks, Inc.
Chapter 37: Packing and Returning Components
• If you are using a mechanical lift, place the lift platform under the router, unscrew and remove the mounting screws from the rack, and move the router to the shipping crate.
• If you are not using a mechanical lift and the router weight is fully supported by a shelf or another router, unscrew and remove the mounting screws from the rack.
Four people can then lift the router and move it to the shipping crate.
• If you are not using a mechanical lift and the router weight is not fully supported by a shelf or another router, four people should grasp the router while a fifth person unscrews and removes the mounting screws from the rack. The four lifters can then move the router to the shipping crate.
9.
Place the router in the shipping crate or onto the pallet. If on a pallet, bolt the router to the pallet.
10.
Cover the router with an ESD bag and place the packing foam on top of and around the router.
11.
Replace the accessory box on top of the packing foam.
12.
Securely tape the box closed or place the crate cover over the router.
13.
Write the RMA number on the exterior of the box to ensure proper tracking.
Related
Documentation
•
T1600 Preventing Electrostatic Discharge Damage on page 588
•
Contacting Customer Support on page 565
Packing the T1600 Router Components for Shipment
To pack and ship individual components:
• When you return components, make sure they are adequately protected with packing materials and packed so that the pieces are prevented from moving around inside the carton.
• Use the original shipping materials if they are available.
• Place individual components in antistatic bags.
• Write the RMA number on the exterior of the box to ensure proper tracking.
CAUTION: Do not stack any of the hardware components.
Related
Documentation
•
Contacting Customer Support on page 565
•
Verifying the T1600 Router Parts Received on page 179
Copyright © 2019, Juniper Networks, Inc.
579
T1600 Core Router Hardware Guide
Returning a Hardware Component to Juniper Networks, Inc.
In the event of a hardware failure, please contact Juniper Networks, Inc. to obtain a Return
Material Authorization (RMA) number. This number is used to track the returned material at the factory and to return repaired or new components to the customer as needed.
NOTE: Do not return any component to Juniper Networks, Inc. unless you have first obtained an RMA number. Juniper Networks, Inc. reserves the right to refuse shipments that do not have an RMA. Refused shipments are returned to the customer by collect freight.
For more information about return and repair policies, see the customer support Web page at https://www.juniper.net/support/guidelines.html
.
For product problems or technical support issues, contact the Juniper Networks Technical
Assistance Center (JTAC) by using the Case Manager link at https://www.juniper.net/support/ or at 1-888-314-JTAC (within the United States) or
1-408-745-9500 (from outside the United States).
To return a defective hardware component:
1.
Determine the part number and serial number of the defective component.
2.
Obtain an RMA number from the Juniper Networks Technical Assistance Center (JTAC).
You can send e-mail or telephone as described above.
3.
Provide the following information in your e-mail message or during the telephone call:
• Part number and serial number of component
• Your name, organization name, telephone number, and fax number
• Description of the failure
4.
The support representative validates your request and issues an RMA number for return of the component.
5.
Pack the component for shipment.
580 Copyright © 2019, Juniper Networks, Inc.
PART 8
Safety and Compliance Information
•
General Safety Guidelines and Warnings on page 583
•
Fire Safety Requirements on page 593
•
Installation Safety Guidelines and Warnings on page 595
•
Laser and LED Safety Guidelines and Warnings on page 603
•
Maintenance and Operational Safety Warnings on page 607
•
Electrical Safety Guidelines and Warnings on page 613
•
Agency Approvals and Compliance Statements on page 625
Copyright © 2019, Juniper Networks, Inc.
581
T1600 Core Router Hardware Guide
582 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 38
General Safety Guidelines and Warnings
•
Definition of Safety Warning Levels on page 583
•
General Safety Guidelines for Juniper Networks Devices on page 585
•
General Safety Warnings for Juniper Networks Devices on page 586
•
T1600 Preventing Electrostatic Discharge Damage on page 588
Definition of Safety Warning Levels
The documentation uses the following levels of safety warnings:
NOTE: You might find this information helpful in a particular situation, or might otherwise overlook it.
CAUTION: You must observe the specified guidelines to avoid minor injury or discomfort to you, or severe damage to the hardware device.
WARNING: This symbol alerts you to the risk of personal injury from a laser.
WARNING: This symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents.
Waarschuwing Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen.
Varoitus Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa,
Copyright © 2019, Juniper Networks, Inc.
583
T1600 Core Router Hardware Guide
584 ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista.
Attention Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant causer des blessures ou des dommages corporels.
Avant de travailler sur un équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents.
Warnung Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer
Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der
Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen
Stromkreisen verbundenen Gefahren und der Standardpraktiken zur
Vermeidung von Unfällen bewußt.
Avvertenza Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti.
Advarsel Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til personskade. Før du utfører arbeid på utstyr, må du vare oppmerksom på de faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med vanlig praksis når det gjelder å unngå ulykker.
Aviso Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos físicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes.
¡Atención!
Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considerar los riesgos que entraña la corriente eléctrica y familiarizarse con los procedimientos estándar de prevención de accidentes.
Varning!
Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador.
Related
Documentation
•
General Safety Warnings for Juniper Networks Devices on page 586
•
Installation Safety Warnings for Juniper Networks Devices on page 595
•
Maintenance and Operational Safety Warnings for Juniper Networks Devices on page 607
•
General Electrical Safety Warnings for Juniper Networks Devices on page 614
•
DC Power Electrical Safety Warnings for Juniper Networks Devices on page 619
Copyright © 2019, Juniper Networks, Inc.
Chapter 38: General Safety Guidelines and Warnings
General Safety Guidelines for Juniper Networks Devices
The following guidelines help ensure your safety and protect the hardware equipment from damage. The list of guidelines might not address all potentially hazardous situations in your working environment, so be alert and exercise good judgment at all times.
• Perform only the procedures explicitly described in this documentation. Make sure that only authorized service personnel perform other system services.
• Keep the area around the chassis clear and free from dust before, during, and after installation.
• Keep tools away from areas where people could trip over them while walking.
• Do not wear loose clothing or jewelry, such as rings, bracelets, or chains, that could become caught in the chassis.
• Wear safety glasses if you are working under any conditions that could be hazardous to your eyes.
• Do not perform any actions that create a potential hazard to people or make the equipment unsafe.
• Never attempt to lift an object that is too heavy for one person to handle.
• Never install or manipulate wiring during electrical storms.
• Never install electrical jacks in wet locations unless the jacks are specifically designed for wet environments.
• Operate the hardware equipment only when the chassis is properly grounded.
• Do not open or remove chassis covers or sheet metal parts unless instructions are provided in this documentation. Such an action could cause severe electrical shock.
• Do not push or force any objects through any opening in the chassis frame. Such an action could result in electrical shock or fire.
• Avoid spilling liquid onto the chassis or onto any hardware component. Such an action could cause electrical shock or damage the hardware equipment.
• Avoid touching uninsulated electrical wires or terminals that have not been disconnected from their power source. Such an action could cause electrical shock.
• Some parts of the router might become hot. The following label provides the warning of the hot surfaces on the router:
Related
Documentation
•
General Safety Warnings for Juniper Networks Devices on page 586
Copyright © 2019, Juniper Networks, Inc.
585
T1600 Core Router Hardware Guide
General Safety Warnings for Juniper Networks Devices
•
Qualified Personnel Warning on page 586
•
Restricted-Access Area Warning on page 586
Qualified Personnel Warning
WARNING: Only trained and qualified personnel should install or replace the hardware equipment.
Waarschuwing Installatie en reparaties mogen uitsluitend door getraind en bevoegd personeel uitgevoerd worden.
Varoitus Ainoastaan koulutettu ja pätevä henkilökunta saa asentaa tai vaihtaa tämän laitteen.
Attention Tout installation ou remplacement de l'appareil doit être réalisé par du personnel qualifié et compétent.
Warnung Gerät nur von geschultem, qualifiziertem Personal installieren oder auswechseln lassen.
Avvertenza Solo personale addestrato e qualificato deve essere autorizzato ad installare o sostituire questo apparecchio.
Advarsel Kun kvalifisert personell med riktig opplæring bør montere eller bytte ut dette utstyret.
Aviso Este equipamento deverá ser instalado ou substituído apenas por pessoal devidamente treinado e qualificado.
¡Atención!
Estos equipos deben ser instalados y reemplazados exclusivamente por personal técnico adecuadamente preparado y capacitado.
Varning!
Denna utrustning ska endast installeras och bytas ut av utbildad och kvalificerad personal.
Restricted-Access Area Warning
WARNING: The hardware equipment is intended for installation in restricted-access areas. A restricted-access area is an area to which access can be gained only by service personnel through the use of a special tool, lock and key, or other means of security, and which is controlled by the authority responsible for the location.
Waarschuwing Dit toestel is bedoeld voor installatie op plaatsen met beperkte toegang. Een plaats met beperkte toegang is een plaats waar toegang slechts door servicepersoneel verkregen kan worden door middel van een speciaal
586 Copyright © 2019, Juniper Networks, Inc.
Chapter 38: General Safety Guidelines and Warnings
Copyright © 2019, Juniper Networks, Inc.
instrument, een slot en sleutel, of een ander veiligheidsmiddel, en welke beheerd wordt door de overheidsinstantie die verantwoordelijk is voor de locatie.
Varoitus Tämä laite on tarkoitettu asennettavaksi paikkaan, johon pääsy on rajoitettua. Paikka, johon pääsy on rajoitettua, tarkoittaa paikkaa, johon vain huoltohenkilöstö pääsee jonkin erikoistyökalun, lukkoon sopivan avaimen tai jonkin muun turvalaitteen avulla ja joka on paikasta vastuussa olevien toimivaltaisten henkilöiden valvoma.
Attention Cet appareil est à installer dans des zones d'accès réservé. Ces dernières sont des zones auxquelles seul le personnel de service peut accéder en utilisant un outil spécial, un mécanisme de verrouillage et une clé, ou tout autre moyen de sécurité. L'accès aux zones de sécurité est sous le contrôle de l'autorité responsable de l'emplacement.
Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem
Zutritt vorgesehen. Ein Bereich mit beschränktem Zutritt ist ein Bereich, zu dem nur Wartungspersonal mit einem Spezialwerkzeugs, Schloß und
Schlüssel oder anderer Sicherheitsvorkehrungen Zugang hat, und der von dem für die Anlage zuständigen Gremium kontrolliert wird.
Avvertenza Questa unità deve essere installata in un'area ad accesso limitato.
Un'area ad accesso limitato è un'area accessibile solo a personale di assistenza tramite un'attrezzo speciale, lucchetto, o altri dispositivi di sicurezza, ed è controllata dall'autorità responsabile della zona.
Advarsel Denne enheten er laget for installasjon i områder med begrenset adgang. Et område med begrenset adgang gir kun adgang til servicepersonale som bruker et spesielt verktøy, lås og nøkkel, eller en annen sikkerhetsanordning, og det kontrolleres av den autoriteten som er ansvarlig for området.
Aviso Esta unidade foi concebida para instalação em áreas de acesso restrito.
Uma área de acesso restrito é uma área à qual apenas tem acesso o pessoal de serviço autorizado, que possua uma ferramenta, chave e fechadura especial, ou qualquer outra forma de segurança. Esta área é controlada pela autoridade responsável pelo local.
¡Atención!
Esta unidad ha sido diseñada para instalarse en áreas de acceso restringido. Área de acceso restringido significa un área a la que solamente tiene acceso el personal de servicio mediante la utilización de una herramienta especial, cerradura con llave, o algún otro medio de seguridad, y que está bajo el control de la autoridad responsable del local.
Varning!
Denna enhet är avsedd för installation i områden med begränsat tillträde. Ett område med begränsat tillträde får endast tillträdas av servicepersonal med ett speciellt verktyg, lås och nyckel, eller annan säkerhetsanordning, och kontrolleras av den auktoritet som ansvarar för området.
587
T1600 Core Router Hardware Guide
Related
Documentation
•
Installation Safety Warnings for Juniper Networks Devices on page 595
•
Maintenance and Operational Safety Warnings for Juniper Networks Devices on page 607
•
General Electrical Safety Warnings for Juniper Networks Devices on page 614
•
DC Power Electrical Safety Warnings for Juniper Networks Devices on page 619
T1600 Preventing Electrostatic Discharge Damage
Many router hardware components are sensitive to damage from static electricity. Some components can be impaired by voltages as low as 30 V. You can easily generate potentially damaging static voltages whenever you handle plastic or foam packing material or if you move components across plastic or carpets. Observe the following guidelines to minimize the potential for electrostatic discharge (ESD) damage, which can cause intermittent or complete component failures:
• Always use an ESD wrist strap or ankle strap, and make sure that it is in direct contact with your skin.
CAUTION: For safety, periodically check the resistance value of the ESD strap. The measurement should be in the range of 1 to 10 Mohms.
• When handling any component that has been removed from the chassis, verify that the equipment end of your ESD strap is attached to one of the ESD points on the chassis, which are shown in
and
• Avoid contact between the component and your clothing. ESD voltages emitted from clothing can still damage components.
• When removing or installing a component, always place it component-side up on an antistatic surface, in an antistatic card rack, or in an electrostatic bag (see
Figure 281 on page 590 ). If you are returning a component, place it in an electrostatic
bag before packing it.
588 Copyright © 2019, Juniper Networks, Inc.
Chapter 38: General Safety Guidelines and Warnings
Figure 279: ESD Point on Front of the T1600 Router
Front-mounting flange
Center-mounting bracket
Craft interface
Fan tray
FPCs
CIP
ESD point
Air filter
Fan tray
Air intake
Copyright © 2019, Juniper Networks, Inc.
589
T1600 Core Router Hardware Guide
Figure 280: ESD Point on Rear of the T1600 Router
590
Figure 281: Placing a Component into an Electrostatic Bag
Copyright © 2019, Juniper Networks, Inc.
Chapter 38: General Safety Guidelines and Warnings
Related
Documentation
•
T1600 General Electrical Safety Guidelines on page 613
•
T1600 Router Description on page 3
•
Contacting Customer Support on page 565
Copyright © 2019, Juniper Networks, Inc.
591
T1600 Core Router Hardware Guide
592 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 39
Fire Safety Requirements
•
Fire Safety Requirements for Juniper Networks Devices on page 593
Fire Safety Requirements for Juniper Networks Devices
•
General Fire Safety Requirements on page 593
•
•
Fire Suppression Equipment on page 593
General Fire Safety Requirements
In the event of a fire emergency involving network devices, the safety of people is the primary concern. Establish procedures for protecting people in a fire emergency, provide safety training, and properly provision fire-control equipment and fire extinguishers.
In addition, establish procedures to protect your equipment in a fire emergency. Juniper
Networks products must be installed in an environment suitable for electronic equipment.
We recommend that fire suppression equipment be available in the event of a fire in the vicinity of the equipment, and that you observe all local fire, safety, and electrical codes and ordinances when installing and operating your equipment.
Fire Suppression
In the event of an electrical hazard or an electrical fire, first turn off power to the equipment at the source. Then use a Type C fire extinguisher, which uses noncorrosive fire retardants, to extinguish the fire.
Fire Suppression Equipment
Type C fire extinguishers, which use noncorrosive fire retardants such as carbon dioxide
(CO
2
) and Halotron, are most effective for suppressing electrical fires. Type C fire extinguishers displace the oxygen from the point of combustion to eliminate the fire. For extinguishing fire on or around equipment that draws air from the environment for cooling, use this type of inert oxygen displacement extinguisher instead of an extinguisher that leave residues on equipment.
Do not use multipurpose Type ABC chemical fire extinguishers (dry chemical fire extinguishers) near Juniper Networks devices. The primary ingredient in these fire extinguishers is monoammonium phosphate, which is very sticky and difficult to clean.
Copyright © 2019, Juniper Networks, Inc.
593
T1600 Core Router Hardware Guide
In addition, in minute amounts of moisture, monoammonium phosphate can become highly corrosive and corrodes most metals.
Any equipment in a room in which a chemical fire extinguisher has been discharged is subject to premature failure and unreliable operation. The equipment is considered to be irreparably damaged.
NOTE: To keep warranties effective, do not use a dry chemical fire extinguisher to control a fire at or near a Juniper Networks device. If a dry chemical fire extinguisher is used, the unit is no longer eligible for coverage under a service agreement.
We recommend that you dispose of any irreparably damaged equipment in an environmentally responsible manner.
Related
Documentation
•
General Safety Guidelines for Juniper Networks Devices on page 585
•
General Safety Warnings for Juniper Networks Devices on page 586
•
General Electrical Safety Warnings for Juniper Networks Devices on page 614
•
DC Power Electrical Safety Warnings for Juniper Networks Devices on page 619
594 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 40
Installation Safety Guidelines and
Warnings
•
T1600 Chassis Lifting Guidelines on page 595
•
Installation Safety Warnings for Juniper Networks Devices on page 595
T1600 Chassis Lifting Guidelines
• Before moving the router, follow the guidelines in the site preparation checklist to verify that the intended site meets the specified power, environmental, and clearance requirements.
• Do not attempt to lift a fully configured router by yourself. Using a mechanical lift to maneuver the router into a rack is recommended. If a lift cannot be used, a minimum of four people is required to lift the router, and you must remove components from the chassis before lifting.
• Before lifting or moving the router, disconnect all external cables.
• As when lifting any heavy object, lift most of the weight with your legs rather than your back. Keep your knees bent and your back relatively straight and avoid twisting your body as you lift. Balance the load evenly and be sure that your footing is solid.
Related
Documentation
•
T1600 Site Preparation Requirements Checklist on page 137
•
Overview of Installing a T1600 Router Without a Mechanical Lift on page 203
•
Overview of Installing a T1600 Router Using a Mechanical Lift on page 195
•
Installation Safety Warnings for Juniper Networks Devices on page 595
Installation Safety Warnings for Juniper Networks Devices
Observe the following warnings before and during hardware equipment installation:
•
Intrabuilding Ports Warning on page 596
•
Installation Instructions Warning on page 596
Copyright © 2019, Juniper Networks, Inc.
595
T1600 Core Router Hardware Guide
•
Rack-Mounting Requirements and Warnings on page 597
•
Intrabuilding Ports Warning
WARNING: The intrabuilding ports of the equipment or subassembly are suitable for connection to intrabuilding or unexposed wiring or cabling only.
The intrabuilding ports of the equipment or subassembly MUST NOT be metallically connected to interfaces that connect to the Outside Plant (OSP) or its wiring. These interfaces are designed for use as intrabuilding interfaces only (Type 2 or Type 4 ports as described in GR-1089) and require isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring.
Installation Instructions Warning
WARNING: Read the installation instructions before you connect the hardware equipment to a power source.
Waarschuwing Raadpleeg de installatie-aanwijzingen voordat u het systeem met de voeding verbindt.
Varoitus Lue asennusohjeet ennen järjestelmän yhdistämistä virtalähteeseen.
Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation.
Warnung Lesen Sie die Installationsanweisungen, bevor Sie das System an die Stromquelle anschließen.
Avvertenza Consultare le istruzioni di installazione prima di collegare il sistema all'alimentatore.
Advarsel Les installasjonsinstruksjonene før systemet kobles til strømkilden.
Aviso Leia as instruções de instalação antes de ligar o sistema à sua fonte de energia.
¡Atención!
Ver las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
Varning!
Läs installationsanvisningarna innan du kopplar systemet till dess strömförsörjningsenhet.
596 Copyright © 2019, Juniper Networks, Inc.
Chapter 40: Installation Safety Guidelines and Warnings
Rack-Mounting Requirements and Warnings
Ensure that the equipment rack into which the chassis is installed is evenly and securely supported, to avoid the hazardous condition that could result from uneven mechanical loading.
WARNING: To prevent bodily injury when mounting or servicing the chassis in a rack, take the following precautions to ensure that the system remains stable. The following directives help maintain your safety:
• The chassis must be installed into a rack that is secured to the building structure.
• The chassis should be mounted at the bottom of the rack if it is the only unit in the rack.
• When mounting the chassis in a partially-filled rack, load the rack from the bottom to the top, with the heaviest component at the bottom of the rack.
• If the rack is provided with stabilizing devices, install the stabilizers before mounting the chassis in the rack or servicing the hardware equipment.
Waarschuwing Om lichamelijk letsel te voorkomen wanneer u dit toestel in een rek monteert of het daar een servicebeurt geeft, moet u speciale voorzorgsmaatregelen nemen om ervoor te zorgen dat het toestel stabiel blijft. De onderstaande richtlijnen worden verstrekt om uw veiligheid te verzekeren:
• De router moet in een stellage worden geïnstalleerd die aan een bouwsel is verankerd.
• Dit toestel dient onderaan in het rek gemonteerd te worden als het toestel het enige in het rek is.
• Wanneer u dit toestel in een gedeeltelijk gevuld rek monteert, dient u het rek van onderen naar boven te laden met het zwaarste onderdeel onderaan in het rek.
• Als het rek voorzien is van stabiliseringshulpmiddelen, dient u de stabilisatoren te monteren voordat u het toestel in het rek monteert of het daar een servicebeurt geeft.
Varoitus Kun laite asetetaan telineeseen tai huolletaan sen ollessa telineessä, on noudatettava erityisiä varotoimia järjestelmän vakavuuden säilyttämiseksi, jotta vältytään loukkaantumiselta. Noudata seuraavia turvallisuusohjeita:
• Router on asennettava telineeseen, joka on kiinnitetty rakennukseen.
• Jos telineessä ei ole muita laitteita, aseta laite telineen alaosaan.
Copyright © 2019, Juniper Networks, Inc.
597
T1600 Core Router Hardware Guide
598
• Jos laite asetetaan osaksi täytettyyn telineeseen, aloita kuormittaminen sen alaosasta kaikkein raskaimmalla esineellä ja siirry sitten sen yläosaan.
• Jos telinettä varten on vakaimet, asenna ne ennen laitteen asettamista telineeseen tai sen huoltamista siinä.
Attention Pour éviter toute blessure corporelle pendant les opérations de montage ou de réparation de cette unité en casier, il convient de prendre des précautions spéciales afin de maintenir la stabilité du système. Les directives ci-dessous sont destinées à assurer la protection du personnel:
• Le rack sur lequel est monté le router doit être fixé à la structure du bâtiment.
• Si cette unité constitue la seule unité montée en casier, elle doit être placée dans le bas.
• Si cette unité est montée dans un casier partiellement rempli, charger le casier de bas en haut en plaçant l'élément le plus lourd dans le bas.
• Si le casier est équipé de dispositifs stabilisateurs, installer les stabilisateurs avant de monter ou de réparer l'unité en casier.
Warnung Zur Vermeidung von Körperverletzung beim Anbringen oder Warten dieser Einheit in einem Gestell müssen Sie besondere Vorkehrungen treffen, um sicherzustellen, daß das System stabil bleibt. Die folgenden Richtlinien sollen zur Gewährleistung Ihrer Sicherheit dienen:
• Der router muß in einem Gestell installiert werden, das in der
Gebäudestruktur verankert ist.
• Wenn diese Einheit die einzige im Gestell ist, sollte sie unten im Gestell angebracht werden.
• Bei Anbringung dieser Einheit in einem zum Teil gefüllten Gestell ist das
Gestell von unten nach oben zu laden, wobei das schwerste Bauteil unten im Gestell anzubringen ist.
• Wird das Gestell mit Stabilisierungszubehör geliefert, sind zuerst die
Stabilisatoren zu installieren, bevor Sie die Einheit im Gestell anbringen oder sie warten.
Avvertenza Per evitare infortuni fisici durante il montaggio o la manutenzione di questa unità in un supporto, occorre osservare speciali precauzioni per garantire che il sistema rimanga stabile. Le seguenti direttive vengono fornite per garantire la sicurezza personale:
• Il router deve essere installato in un telaio, il quale deve essere fissato alla struttura dell'edificio.
• Questa unità deve venire montata sul fondo del supporto, se si tratta dell'unica unità da montare nel supporto.
Copyright © 2019, Juniper Networks, Inc.
Copyright © 2019, Juniper Networks, Inc.
Chapter 40: Installation Safety Guidelines and Warnings
• Quando questa unità viene montata in un supporto parzialmente pieno, caricare il supporto dal basso all'alto, con il componente più pesante sistemato sul fondo del supporto.
• Se il supporto è dotato di dispositivi stabilizzanti, installare tali dispositivi prima di montare o di procedere alla manutenzione dell'unità nel supporto.
Advarsel Unngå fysiske skader under montering eller reparasjonsarbeid på denne enheten når den befinner seg i et kabinett. Vær nøye med at systemet er stabilt. Følgende retningslinjer er gitt for å verne om sikkerheten:
• Router må installeres i et stativ som er forankret til bygningsstrukturen.
• Denne enheten bør monteres nederst i kabinettet hvis dette er den eneste enheten i kabinettet.
• Ved montering av denne enheten i et kabinett som er delvis fylt, skal kabinettet lastes fra bunnen og opp med den tyngste komponenten nederst i kabinettet.
• Hvis kabinettet er utstyrt med stabiliseringsutstyr, skal stabilisatorene installeres før montering eller utføring av reparasjonsarbeid på enheten i kabinettet.
Aviso Para se prevenir contra danos corporais ao montar ou reparar esta unidade numa estante, deverá tomar precauções especiais para se certificar de que o sistema possui um suporte estável. As seguintes directrizes ajudá-lo-ão a efectuar o seu trabalho com segurança:
• O router deverá ser instalado numa prateleira fixa à estrutura do edificio.
• Esta unidade deverá ser montada na parte inferior da estante, caso seja esta a única unidade a ser montada.
• Ao montar esta unidade numa estante parcialmente ocupada, coloque os itens mais pesados na parte inferior da estante, arrumando-os de baixo para cima.
• Se a estante possuir um dispositivo de estabilização, instale-o antes de montar ou reparar a unidade.
¡Atención!
Para evitar lesiones durante el montaje de este equipo sobre un bastidor, o posteriormente durante su mantenimiento, se debe poner mucho cuidado en que el sistema quede bien estable. Para garantizar su seguridad, proceda según las siguientes instrucciones:
• El router debe instalarse en un bastidor fijado a la estructura del edificio.
• Colocar el equipo en la parte inferior del bastidor, cuando sea la única unidad en el mismo.
599
T1600 Core Router Hardware Guide
Ramp Warning
• Cuando este equipo se vaya a instalar en un bastidor parcialmente ocupado, comenzar la instalación desde la parte inferior hacia la superior colocando el equipo más pesado en la parte inferior.
• Si el bastidor dispone de dispositivos estabilizadores, instalar éstos antes de montar o proceder al mantenimiento del equipo instalado en el bastidor.
Varning!
För att undvika kroppsskada när du installerar eller utför underhållsarbete på denna enhet på en ställning måste du vidta särskilda försiktighetsåtgärder för att försäkra dig om att systemet står stadigt. Följande riktlinjer ges för att trygga din säkerhet:
• Router måste installeras i en ställning som är förankrad i byggnadens struktur.
• Om denna enhet är den enda enheten på ställningen skall den installeras längst ned på ställningen.
• Om denna enhet installeras på en delvis fylld ställning skall ställningen fyllas nedifrån och upp, med de tyngsta enheterna längst ned på ställningen.
• Om ställningen är försedd med stabiliseringsdon skall dessa monteras fast innan enheten installeras eller underhålls på ställningen.
WARNING: When installing the hardware equipment, do not use a ramp inclined at more than 10 degrees.
Waarschuwing Gebruik een oprijplaat niet onder een hoek van meer dan 10 graden.
Varoitus Älä käytä sellaista kaltevaa pintaa, jonka kaltevuus ylittää 10 astetta.
Attention Ne pas utiliser une rampe dont l'inclinaison est supérieure à 10 degrés.
Warnung Keine Rampen mit einer Neigung von mehr als 10 Grad verwenden.
Avvertenza Non usare una rampa con pendenza superiore a 10 gradi.
Advarsel Bruk aldri en rampe som heller mer enn 10 grader.
Aviso Não utilize uma rampa com uma inclinação superior a 10 graus.
¡Atención!
No usar una rampa inclinada más de 10 grados
Varning!
Använd inte ramp med en lutning på mer än 10 grader.
600 Copyright © 2019, Juniper Networks, Inc.
Chapter 40: Installation Safety Guidelines and Warnings
Related
Documentation
•
General Safety Guidelines for Juniper Networks Devices on page 585
•
General Safety Warnings for Juniper Networks Devices on page 586
•
Maintenance and Operational Safety Warnings for Juniper Networks Devices on page 607
Copyright © 2019, Juniper Networks, Inc.
601
T1600 Core Router Hardware Guide
602 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 41
Laser and LED Safety Guidelines and
Warnings
•
T1600 General Laser Safety Guidelines on page 603
•
Laser Safety Warnings for Juniper Networks Devices on page 604
T1600 General Laser Safety Guidelines
Devices with single-mode optical interfaces are equipped with laser transmitters, which are considered Class 1 Laser product by the U.S. Food and Drug Administration, and are evaluated as a Class 1 Laser Product according to EN 60825–1 +A11 +A2 requirements.
When working around devices with optical interfaces, observe the following safety guidelines to prevent eye injury:
• Do not look into unterminated ports or at fibers that connect to unknown sources.
• Do not examine unterminated optical ports with optical instruments.
• Avoid direct exposure to the beam.
WARNING: Unterminated optical connectors can emit invisible laser radiation. The lens in the human eye focuses all the laser power on the retina, so focusing the eye directly on a laser source—even a low-power laser—could permanently damage the eye.
Related
Documentation
•
Connecting PIC Cables to the T1600 Router on page 242
•
Replacing a T1600 PIC on page 402
•
Replacing a T1600 PIC Cable on page 408
• Replacing a T1600 PIC Transceiver
•
General Safety Guidelines for Juniper Networks Devices on page 585
Copyright © 2019, Juniper Networks, Inc.
603
T1600 Core Router Hardware Guide
Laser Safety Warnings for Juniper Networks Devices
•
Class 1 Laser Product Warning on page 604
•
Class 1 LED Product Warning on page 604
•
Laser Beam Warning on page 605
•
Radiation from Open Port Apertures Warning on page 605
Class 1 Laser Product Warning
WARNING: Class 1 laser product.
Waarschuwing Klasse-1 laser produkt.
Varoitus Luokan 1 lasertuote.
Attention Produit laser de classe I.
Warnung Laserprodukt der Klasse 1.
Avvertenza Prodotto laser di Classe 1.
Advarsel Laserprodukt av klasse 1.
Aviso Produto laser de classe 1.
¡Atención!
Producto láser Clase I.
Varning!
Laserprodukt av klass 1.
Class 1 LED Product Warning
WARNING: Class 1 LED product.
Waarschuwing Klasse 1 LED-product.
Varoitus Luokan 1 valodiodituote.
Attention Alarme de produit LED Class I.
Warnung Class 1 LED-Produktwarnung.
Avvertenza Avvertenza prodotto LED di Classe 1.
Advarsel LED-produkt i klasse 1.
Aviso Produto de classe 1 com LED.
¡Atención!
Aviso sobre producto LED de Clase 1.
Varning!
Lysdiodprodukt av klass 1.
604 Copyright © 2019, Juniper Networks, Inc.
Chapter 41: Laser and LED Safety Guidelines and Warnings
Laser Beam Warning
WARNING: Do not stare into the laser beam or view it directly with optical instruments.
Waarschuwing Niet in de straal staren of hem rechtstreeks bekijken met optische instrumenten.
Varoitus Älä katso säteeseen äläkä tarkastele sitä suoraan optisen laitteen avulla.
Attention Ne pas fixer le faisceau des yeux, ni l'observer directement à l'aide d'instruments optiques.
Warnung Nicht direkt in den Strahl blicken und ihn nicht direkt mit optischen
Geräten prüfen.
Avvertenza Non fissare il raggio con gli occhi né usare strumenti ottici per osservarlo direttamente.
Advarsel Stirr eller se ikke direkte p strlen med optiske instrumenter.
Aviso Não olhe fixamente para o raio, nem olhe para ele directamente com instrumentos ópticos.
¡Atención!
No mirar fijamente el haz ni observarlo directamente con instrumentos ópticos.
Varning!
Rikta inte blicken in mot strålen och titta inte direkt på den genom optiska instrument.
Radiation from Open Port Apertures Warning
WARNING: Because invisible radiation might be emitted from the aperture of the port when no fiber-optic cable is connected, avoid exposure to radiation and do not stare into open apertures.
Waarschuwing Aangezien onzichtbare straling vanuit de opening van de poort kan komen als er geen fiberkabel aangesloten is, dient blootstelling aan straling en het kijken in open openingen vermeden te worden.
Varoitus Koska portin aukosta voi emittoitua näkymätöntä säteilyä, kun kuitukaapelia ei ole kytkettynä, vältä säteilylle altistumista äläkä katso avoimiin aukkoihin.
Attention Des radiations invisibles à l'il nu pouvant traverser l'ouverture du port lorsqu'aucun câble en fibre optique n'y est connecté, il est recommandé de ne pas regarder fixement l'intérieur de ces ouvertures.
Copyright © 2019, Juniper Networks, Inc.
605
T1600 Core Router Hardware Guide
Warnung Aus der Port-Öffnung können unsichtbare Strahlen emittieren, wenn kein Glasfaserkabel angeschlossen ist. Vermeiden Sie es, sich den
Strahlungen auszusetzen, und starren Sie nicht in die Öffnungen!
Avvertenza Quando i cavi in fibra non sono inseriti, radiazioni invisibili possono essere emesse attraverso l'apertura della porta. Evitate di esporvi alle radiazioni e non guardate direttamente nelle aperture.
Advarsel Unngå utsettelse for stråling, og stirr ikke inn i åpninger som er åpne, fordi usynlig stråling kan emiteres fra portens åpning når det ikke er tilkoblet en fiberkabel.
Aviso Dada a possibilidade de emissão de radiação invisível através do orifício da via de acesso, quando esta não tiver nenhum cabo de fibra conectado, deverá evitar a exposição à radiação e não deverá olhar fixamente para orifícios que se encontrarem a descoberto.
¡Atención!
Debido a que la apertura del puerto puede emitir radiación invisible cuando no existe un cable de fibra conectado, evite mirar directamente a las aperturas para no exponerse a la radiación.
Varning!
Osynlig strålning kan avges från en portöppning utan ansluten fiberkabel och du bör därför undvika att bli utsatt för strålning genom att inte stirra in i oskyddade öppningar.
Related
Documentation
•
General Safety Guidelines for Juniper Networks Devices on page 585
•
General Safety Warnings for Juniper Networks Devices on page 586
•
Installation Safety Warnings for Juniper Networks Devices on page 595
606 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 42
Maintenance and Operational Safety
Warnings
•
Maintenance and Operational Safety Warnings for Juniper Networks Devices on page 607
Maintenance and Operational Safety Warnings for Juniper Networks Devices
As you maintain the hardware equipment, observe the following warnings:
•
Battery Handling Warning on page 607
•
Jewelry Removal Warning on page 608
•
Lightning Activity Warning on page 609
•
Operating Temperature Warning on page 610
•
Product Disposal Warning on page 611
Battery Handling Warning
WARNING: Replacing the battery incorrectly might result in an explosion.
Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.
Waarschuwing Er is ontploffingsgevaar als de batterij verkeerd vervangen wordt. Vervang de batterij slechts met hetzelfde of een equivalent type dat door de fabrikant aanbevolen is. Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften weggeworpen te worden.
Varoitus Räjähdyksen vaara, jos akku on vaihdettu väärään akkuun. Käytä vaihtamiseen ainoastaan saman- tai vastaavantyyppistä akkua, joka on valmistajan suosittelema. Hävitä käytetyt akut valmistajan ohjeiden mukaan.
Attention Danger d'explosion si la pile n'est pas remplacée correctement.
Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant. Jeter les piles usagées conformément aux instructions du fabricant.
Copyright © 2019, Juniper Networks, Inc.
607
T1600 Core Router Hardware Guide
Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr.
Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den
Anweisungen des Herstellers.
Avvertenza Pericolo di esplosione se la batteria non è installata correttamente. Sostituire solo con una di tipo uguale o equivalente, consigliata dal produttore. Eliminare le batterie usate secondo le istruzioni del produttore.
Advarsel Det kan være fare for eksplosjon hvis batteriet skiftes på feil måte.
Skift kun med samme eller tilsvarende type som er anbefalt av produsenten.
Kasser brukte batterier i henhold til produsentens instruksjoner.
Aviso Existe perigo de explosão se a bateria for substituída incorrectamente.
Substitua a bateria por uma bateria igual ou de um tipo equivalente recomendado pelo fabricante. Destrua as baterias usadas conforme as instruções do fabricante.
¡Atención!
Existe peligro de explosión si la batería se reemplaza de manera incorrecta. Reemplazar la batería exclusivamente con el mismo tipo o el equivalente recomendado por el fabricante. Desechar las baterías gastadas según las instrucciones del fabricante.
Varning!
Explosionsfara vid felaktigt batteribyte. Ersätt endast batteriet med samma batterityp som rekommenderas av tillverkaren eller motsvarande.
Följ tillverkarens anvisningar vid kassering av använda batterier.
Jewelry Removal Warning
WARNING: Before working on equipment that is connected to power lines, remove jewelry, including rings, necklaces, and watches. Metal objects heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals.
Waarschuwing Alvorens aan apparatuur te werken die met elektrische leidingen is verbonden, sieraden (inclusief ringen, kettingen en horloges) verwijderen. Metalen voorwerpen worden warm wanneer ze met stroom en aarde zijn verbonden, en kunnen ernstige brandwonden veroorzaken of het metalen voorwerp aan de aansluitklemmen lassen.
Varoitus Ennen kuin työskentelet voimavirtajohtoihin kytkettyjen laitteiden parissa, ota pois kaikki korut (sormukset, kaulakorut ja kellot mukaan lukien).
Metalliesineet kuumenevat, kun ne ovat yhteydessä sähkövirran ja maan kanssa, ja ne voivat aiheuttaa vakavia palovammoja tai hitsata metalliesineet kiinni liitäntänapoihin.
Attention Avant d'accéder à cet équipement connecté aux lignes électriques,
ôter tout bijou (anneaux, colliers et montres compris). Lorsqu'ils sont branchés
608 Copyright © 2019, Juniper Networks, Inc.
Chapter 42: Maintenance and Operational Safety Warnings
à l'alimentation et reliés à la terre, les objets métalliques chauffent, ce qui peut provoquer des blessures graves ou souder l'objet métallique aux bornes.
Warnung Vor der Arbeit an Geräten, die an das Netz angeschlossen sind, jeglichen Schmuck (einschließlich Ringe, Ketten und Uhren) abnehmen.
Metallgegenstände erhitzen sich, wenn sie an das Netz und die Erde angeschlossen werden, und können schwere Verbrennungen verursachen oder an die Anschlußklemmen angeschweißt werden.
Avvertenza Prima di intervenire su apparecchiature collegate alle linee di alimentazione, togliersi qualsiasi monile (inclusi anelli, collane, braccialetti ed orologi). Gli oggetti metallici si riscaldano quando sono collegati tra punti di alimentazione e massa: possono causare ustioni gravi oppure il metallo può saldarsi ai terminali.
Advarsel Fjern alle smykker (inkludert ringer, halskjeder og klokker) før du skal arbeide på utstyr som er koblet til kraftledninger. Metallgjenstander som er koblet til kraftledninger og jord blir svært varme og kan forårsake alvorlige brannskader eller smelte fast til polene.
Aviso Antes de trabalhar em equipamento que esteja ligado a linhas de corrente, retire todas as jóias que estiver a usar (incluindo anéis, fios e relógios). Os objectos metálicos aquecerão em contacto com a corrente e em contacto com a ligação à terra, podendo causar queimaduras graves ou ficarem soldados aos terminais.
¡Atención!
Antes de operar sobre equipos conectados a líneas de alimentación, quitarse las joyas (incluidos anillos, collares y relojes). Los objetos de metal se calientan cuando se conectan a la alimentación y a tierra, lo que puede ocasionar quemaduras graves o que los objetos metálicos queden soldados a los bornes.
Varning!
Tag av alla smycken (inklusive ringar, halsband och armbandsur) innan du arbetar på utrustning som är kopplad till kraftledningar. Metallobjekt hettas upp när de kopplas ihop med ström och jord och kan förorsaka allvarliga brännskador; metallobjekt kan också sammansvetsas med kontakterna.
Lightning Activity Warning
WARNING: Do not work on the system or connect or disconnect cables during periods of lightning activity.
Waarschuwing Tijdens onweer dat gepaard gaat met bliksem, dient u niet aan het systeem te werken of kabels aan te sluiten of te ontkoppelen.
Varoitus Älä työskentele järjestelmän parissa äläkä yhdistä tai irrota kaapeleita ukkosilmalla.
Copyright © 2019, Juniper Networks, Inc.
609
T1600 Core Router Hardware Guide
Attention Ne pas travailler sur le système ni brancher ou débrancher les câbles pendant un orage.
Warnung Arbeiten Sie nicht am System und schließen Sie keine Kabel an bzw. trennen Sie keine ab, wenn es gewittert.
Avvertenza Non lavorare sul sistema o collegare oppure scollegare i cavi durante un temporale con fulmini.
Advarsel Utfør aldri arbeid på systemet, eller koble kabler til eller fra systemet når det tordner eller lyner.
Aviso Não trabalhe no sistema ou ligue e desligue cabos durante períodos de mau tempo (trovoada).
¡Atención!
No operar el sistema ni conectar o desconectar cables durante el transcurso de descargas eléctricas en la atmósfera.
Varning!
Vid åska skall du aldrig utföra arbete på systemet eller ansluta eller koppla loss kablar.
Operating Temperature Warning
WARNING: To prevent the hardware equipment from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of 104° F (40° C). To prevent airflow restriction, allow at least
6 inches (15.2 cm) of clearance around the ventilation openings.
Waarschuwing Om te voorkomen dat welke router van de router dan ook oververhit raakt, dient u deze niet te bedienen op een plaats waar de maximale aanbevolen omgevingstemperatuur van 40° C wordt overschreden. Om te voorkomen dat de luchtstroom wordt beperkt, dient er minstens 15,2 cm speling rond de ventilatie-openingen te zijn.
Varoitus Ettei router-sarjan reititin ylikuumentuisi, sitä ei saa käyttää tilassa, jonka lämpötila ylittää korkeimman suositellun ympäristölämpötilan 40° C.
Ettei ilmanvaihto estyisi, tuuletusaukkojen ympärille on jätettävä ainakin
15,2 cm tilaa.
Attention Pour éviter toute surchauffe des routeurs de la gamme router, ne l'utilisez pas dans une zone où la température ambiante est supérieure à
40° C. Pour permettre un flot d'air constant, dégagez un espace d'au moins
15,2 cm autour des ouvertures de ventilations.
Warnung Um einen router der router vor Überhitzung zu schützen, darf dieser nicht in einer Gegend betrieben werden, in der die Umgebungstemperatur das empfohlene Maximum von 40° C überschreitet. Um Lüftungsverschluß zu verhindern, achten Sie darauf, daß mindestens 15,2 cm lichter Raum um die Lüftungsöffnungen herum frei bleibt.
610 Copyright © 2019, Juniper Networks, Inc.
Chapter 42: Maintenance and Operational Safety Warnings
Avvertenza Per evitare il surriscaldamento dei router, non adoperateli in un locale che ecceda la temperatura ambientale massima di 40° C. Per evitare che la circolazione dell'aria sia impedita, lasciate uno spazio di almeno 15.2 cm di fronte alle aperture delle ventole.
Advarsel Unngå overoppheting av eventuelle rutere i router Disse skal ikke brukes på steder der den anbefalte maksimale omgivelsestemperaturen overstiger 40° C (104° F). Sørg for at klaringen rundt lufteåpningene er minst
15,2 cm (6 tommer) for å forhindre nedsatt luftsirkulasjon.
Aviso Para evitar o sobreaquecimento do encaminhador router, não utilize este equipamento numa área que exceda a temperatura máxima recomendada de 40° C. Para evitar a restrição à circulação de ar, deixe pelo menos um espaço de 15,2 cm à volta das aberturas de ventilação.
¡Atención!
Para impedir que un encaminador de la serie router se recaliente, no lo haga funcionar en un área en la que se supere la temperatura ambiente máxima recomendada de 40° C. Para impedir la restricción de la entrada de aire, deje un espacio mínimo de 15,2 cm alrededor de las aperturas para ventilación.
Varning!
Förhindra att en router överhettas genom att inte använda den i ett område där den maximalt rekommenderade omgivningstemperaturen på
40° C överskrids. Förhindra att luftcirkulationen inskränks genom att se till att det finns fritt utrymme på minst 15,2 cm omkring ventilationsöppningarna.
Product Disposal Warning
WARNING: Disposal of this product must be handled according to all national laws and regulations.
Waarschuwing Dit produkt dient volgens alle landelijke wetten en voorschriften te worden afgedankt.
Varoitus Tämän tuotteen lopullisesta hävittämisestä tulee huolehtia kaikkia valtakunnallisia lakeja ja säännöksiä noudattaen.
Attention La mise au rebut définitive de ce produit doit être effectuée conformément à toutes les lois et réglementations en vigueur.
Warnung Dieses Produkt muß den geltenden Gesetzen und Vorschriften entsprechend entsorgt werden.
Avvertenza L'eliminazione finale di questo prodotto deve essere eseguita osservando le normative italiane vigenti in materia
Advarsel Endelig disponering av dette produktet må skje i henhold til nasjonale lover og forskrifter.
Copyright © 2019, Juniper Networks, Inc.
611
T1600 Core Router Hardware Guide
Aviso A descartagem final deste produto deverá ser efectuada de acordo com os regulamentos e a legislação nacional.
¡Atención!
El desecho final de este producto debe realizarse según todas las leyes y regulaciones nacionales
Varning!
Slutlig kassering av denna produkt bör skötas i enlighet med landets alla lagar och föreskrifter.
Related
Documentation
•
General Safety Guidelines for Juniper Networks Devices on page 585
•
General Safety Warnings for Juniper Networks Devices on page 586
612 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 43
Electrical Safety Guidelines and Warnings
•
T1600 General Electrical Safety Guidelines on page 613
•
General Electrical Safety Warnings for Juniper Networks Devices on page 614
•
T1600 DC Power Electrical Safety Guidelines on page 618
•
DC Power Electrical Safety Warnings for Juniper Networks Devices on page 619
•
Site Electrical Wiring Guidelines for Juniper Networks Devices on page 622
T1600 General Electrical Safety Guidelines
• Install the router in compliance with the following local, national, or international electrical codes:
• United States—National Fire Protection Association (NFPA 70), United States
National Electrical Code.
• Canada—Canadian Electrical Code, Part 1, CSA C22.1.
• Other countries—International Electromechanical Commission (IEC) 60364, Part 1 through Part 7.
• Locate the emergency power-off switch for the room in which you are working so that if an electrical accident occurs, you can quickly turn off the power.
• Do not work alone if potentially hazardous conditions exist anywhere in your workspace.
• Never assume that power is disconnected from a circuit. Always check the circuit before starting to work.
• Carefully look for possible hazards in your work area, such as moist floors, ungrounded power extension cords, and missing safety grounds.
• Operate the router within marked electrical ratings and product usage instructions.
• For the router and peripheral equipment to function safely and correctly, use the cables and connectors specified for the attached peripheral equipment, and make certain they are in good condition.
Many router components can be removed and replaced without powering off or disconnecting power to the router. Never install equipment if it appears damaged.
Copyright © 2019, Juniper Networks, Inc.
613
T1600 Core Router Hardware Guide
Related
Documentation
•
T1600 Router Description on page 3
•
General Safety Guidelines for Juniper Networks Devices on page 585
•
T1600 Site Preparation Requirements Checklist on page 137
•
T1600 Field-Replaceable Units on page 309
General Electrical Safety Warnings for Juniper Networks Devices
•
Grounded Equipment Warning on page 614
•
Grounding Requirements and Warning on page 615
•
Midplane Energy Hazard Warning on page 615
•
Multiple Power Supplies Disconnection Warning on page 616
•
Power Disconnection Warning on page 616
Grounded Equipment Warning
WARNING: The network device is intended to be grounded. Ensure that the network device is connected to earth ground during normal use.
Waarschuwing Deze apparatuur hoort geaard te worden Zorg dat de host-computer tijdens normaal gebruik met aarde is verbonden.
Varoitus Tämä laitteisto on tarkoitettu maadoitettavaksi. Varmista, että isäntälaite on yhdistetty maahan normaalikäytön aikana.
Attention Cet équipement doit être relié à la terre. S'assurer que l'appareil hôte est relié à la terre lors de l'utilisation normale.
Warnung Dieses Gerät muß geerdet werden. Stellen Sie sicher, daß das
Host-Gerät während des normalen Betriebs an Erde gelegt ist.
Avvertenza Questa apparecchiatura deve essere collegata a massa. Accertarsi che il dispositivo host sia collegato alla massa di terra durante il normale utilizzo.
Advarsel Dette utstyret skal jordes. Forviss deg om vertsterminalen er jordet ved normalt bruk.
Aviso Este equipamento deverá estar ligado à terra. Certifique-se que o host se encontra ligado à terra durante a sua utilização normal.
¡Atención!
Este equipo debe conectarse a tierra. Asegurarse de que el equipo principal esté conectado a tierra durante el uso normal.
Varning!
Denna utrustning är avsedd att jordas. Se till att värdenheten är jordad vid normal användning.
614 Copyright © 2019, Juniper Networks, Inc.
Chapter 43: Electrical Safety Guidelines and Warnings
Grounding Requirements and Warning
An insulated grounding conductor that is identical in size to the grounded and ungrounded branch circuit supply conductors, but is identifiable by green and yellow stripes, is installed as part of the branch circuit that supplies the unit. The grounding conductor is a separately derived system at the supply transformer or motor generator set.
WARNING: When installing the network device, you must always make the ground connection first and disconnect it last.
Waarschuwing Bij de installatie van het toestel moet de aardverbinding altijd het eerste worden gemaakt en het laatste worden losgemaakt.
Varoitus Laitetta asennettaessa on maahan yhdistäminen aina tehtävä ensiksi ja maadoituksen irti kytkeminen viimeiseksi.
Attention Lors de l'installation de l'appareil, la mise à la terre doit toujours
être connectée en premier et déconnectée en dernier.
Warnung Der Erdanschluß muß bei der Installation der Einheit immer zuerst hergestellt und zuletzt abgetrennt werden.
Avvertenza In fase di installazione dell'unità, eseguire sempre per primo il collegamento a massa e disconnetterlo per ultimo.
Advarsel Når enheten installeres, må jordledningen alltid tilkobles først og frakobles sist.
Aviso Ao instalar a unidade, a ligação à terra deverá ser sempre a primeira a ser ligada, e a última a ser desligada.
¡Atención!
Al instalar el equipo, conectar la tierra la primera y desconectarla la última.
Varning!
Vid installation av enheten måste jordledningen alltid anslutas först och kopplas bort sist.
Midplane Energy Hazard Warning
WARNING: High levels of electrical energy are distributed across the midplane.
Be careful not to contact the midplane connectors, or any component connected to the midplane, with any metallic object while servicing components.
Copyright © 2019, Juniper Networks, Inc.
615
T1600 Core Router Hardware Guide
Multiple Power Supplies Disconnection Warning
WARNING: The network device has more than one power supply connection.
All connections must be removed completely to remove power from the unit completely.
Waarschuwing Deze eenheid heeft meer dan één stroomtoevoerverbinding; alle verbindingen moeten volledig worden verwijderd om de stroom van deze eenheid volledig te verwijderen.
Varoitus Tässä laitteessa on useampia virtalähdekytkentöjä. Kaikki kytkennät on irrotettava kokonaan, jotta virta poistettaisiin täysin laitteesta.
Attention Cette unité est équipée de plusieurs raccordements d'alimentation.
Pour supprimer tout courant électrique de l'unité, tous les cordons d'alimentation doivent être débranchés.
Warnung Diese Einheit verfügt über mehr als einen Stromanschluß; um Strom gänzlich von der Einheit fernzuhalten, müssen alle Stromzufuhren abgetrennt sein.
Avvertenza Questa unità ha più di una connessione per alimentatore elettrico; tutte le connessioni devono essere completamente rimosse per togliere l'elettricità dall'unità.
Advarsel Denne enheten har mer enn én strømtilkobling. Alle tilkoblinger må kobles helt fra for å eliminere strøm fra enheten.
Aviso Este dispositivo possui mais do que uma conexão de fonte de alimentação de energia; para poder remover a fonte de alimentação de energia, deverão ser desconectadas todas as conexões existentes.
¡Atención!
Esta unidad tiene más de una conexión de suministros de alimentación; para eliminar la alimentación por completo, deben desconectarse completamente todas las conexiones.
Varning!
Denna enhet har mer än en strömförsörjningsanslutning; alla anslutningar måste vara helt avlägsnade innan strömtillförseln till enheten
är fullständigt bruten.
Power Disconnection Warning
WARNING: Before working on the chassis or near power supplies, switch off the power at the DC circuit breaker.
Waarschuwing Voordat u aan een frame of in de nabijheid van voedingen werkt, dient u bij wisselstroom toestellen de stekker van het netsnoer uit het
616 Copyright © 2019, Juniper Networks, Inc.
Chapter 43: Electrical Safety Guidelines and Warnings stopcontact te halen; voor gelijkstroom toestellen dient u de stroom uit te schakelen bij de stroomverbreker.
Varoitus Kytke irti vaihtovirtalaitteiden virtajohto ja katkaise tasavirtalaitteiden virta suojakytkimellä, ennen kuin teet mitään asennuspohjalle tai työskentelet virtalähteiden läheisyydessä.
Attention Avant de travailler sur un châssis ou à proximité d'une alimentation
électrique, débrancher le cordon d'alimentation des unités en courant alternatif; couper l'alimentation des unités en courant continu au niveau du disjoncteur.
Warnung Bevor Sie an einem Chassis oder in der Nähe von Netzgeräten arbeiten, ziehen Sie bei Wechselstromeinheiten das Netzkabel ab bzw.
schalten Sie bei Gleichstromeinheiten den Strom am Unterbrecher ab.
Avvertenza Prima di lavorare su un telaio o intorno ad alimentatori, scollegare il cavo di alimentazione sulle unità CA; scollegare l'alimentazione all'interruttore automatico sulle unità CC.
Advarsel Før det utføres arbeid på kabinettet eller det arbeides i nærheten av strømforsyningsenheter, skal strømledningen trekkes ut p vekselstrømsenheter og strømmen kobles fra ved strømbryteren på likestrømsenheter.
Aviso Antes de trabalhar num chassis, ou antes de trabalhar perto de unidades de fornecimento de energia, desligue o cabo de alimentação nas unidades de corrente alternada; desligue a corrente no disjuntor nas unidades de corrente contínua.
¡Atención!
Antes de manipular el chasis de un equipo o trabajar cerca de una fuente de alimentación, desenchufar el cable de alimentación en los equipos de corriente alterna (CA); cortar la alimentación desde el interruptor automático en los equipos de corriente continua (CC).
Varning!
Innan du arbetar med ett chassi eller nära strömförsörjningsenheter skall du för växelströmsenheter dra ur nätsladden och för likströmsenheter bryta strömmen vid överspänningsskyddet.
Related
Documentation
•
DC Power Electrical Safety Warnings for Juniper Networks Devices on page 619
Copyright © 2019, Juniper Networks, Inc.
617
T1600 Core Router Hardware Guide
T1600 DC Power Electrical Safety Guidelines
The following electrical safety guidelines apply to a DC-powered router:
• Be sure to connect the ground wire or conduit to a solid office (earth) ground. A closed loop ring is recommended for terminating the ground conductor at the ground stud.
• A DC-powered router is equipped with a DC terminal block that is rated for the power requirements of a maximally configured router.
To supply sufficient power, terminate the DC input wiring on a facility DC source capable of supplying at least 67 A @ –48 VDC per input for the three-input 240-A DC power supply, 48 A @ –48 VDC per input for the four-input 240-A DC power supply, or 56 A
@ –48 VDC per input for the six-input DC power supply.
• Incorporate an easily accessible disconnect device into the facility wiring. In the United
States and Canada, the –48 VDC facility should be equipped with a circuit breaker rated a minimum of 125% of the power provisioned for the input in accordance with the National Electrical Code in the US and the Canadian Electrical Code in Canada.
WARNING: For the six-input DC power supply, failure to provide the required circuit breaker or current-limiting fuse for each DC power cable can cause injury or damage to equipment.
For the six-input DC power supply, each 48 VDC facility DC source input power cable must be equipped with a current-limiting fuse or circuit breaker external to the Juniper
Networks equipment rated at 80 A (–48 VDC) maximum. The voltage rating of the facility DC source circuit breaker must be 80 V minimum. We recommend an 80 A circuit breaker or current-limiting fuse rated for each 60 A DC power cable.
We recommend that the 48 VDC facility DC source be equipped with a circuit breaker rated at 80 A (–48 VDC) minimum for the three-input 240-A DC power supply or
60 A (–48 VDC) minimum for the four-input 240-A power supply, or as required by local code.
• Run two wires from the circuit breaker box to a source of 48 VDC. Use appropriate gauge wire to handle up to 80 A for a three-input 240-A DC power supply or 60 A for a four-input 240-A power supply.
• A DC-powered router that is equipped with a DC terminal block is intended only for installation in a restricted access location. In the United States, a restricted access area is one in accordance with Articles 110-16, 110-17, and 110-18 of the National Electrical
Code ANSI/NFPA 70.
NOTE: Primary overcurrent protection is provided by the building circuit breaker. This breaker should protect against excess currents, short circuits, and earth faults in accordance with NEC ANSI/NFPA70.
618 Copyright © 2019, Juniper Networks, Inc.
Chapter 43: Electrical Safety Guidelines and Warnings
• Ensure that the polarity of the DC input wiring is correct. Under certain conditions, connections with reversed polarity might trip the primary circuit breaker or damage the equipment.
• For personal safety, connect the green and yellow wire to safety (earth) ground at both the router and the supply side of the DC wiring.
• The marked input voltage of –48 VDC for a DC-powered router is the nominal voltage associated with the battery circuit, and any higher voltages are only to be associated with float voltages for the charging function.
• Because the router is a positive ground system, you must connect the positive lead to the terminal labeled RTN , the negative lead to the terminal labeled –48V , and the earth ground to the chassis grounding points.
Related
Documentation
•
Site Electrical Wiring Guidelines for Juniper Networks Devices on page 622
•
T1600 General Electrical Safety Guidelines on page 613
•
T1600 DC Power System Electrical Specifications on page 145
DC Power Electrical Safety Warnings for Juniper Networks Devices
When working with DC-powered equipment, observe the following warnings:
•
DC Power Copper Conductors Warning on page 619
•
DC Power Disconnection Warning on page 620
•
DC Power Wiring Terminations Warning on page 621
DC Power Copper Conductors Warning
WARNING: Use copper conductors only.
Waarschuwing Gebruik alleen koperen geleiders.
Varoitus Käytä vain kuparijohtimia.
Attention Utilisez uniquement des conducteurs en cuivre.
Warnung Verwenden Sie ausschließlich Kupferleiter.
Avvertenza Usate unicamente dei conduttori di rame.
Advarsel Bruk bare kobberledninger.
Aviso Utilize apenas fios condutores de cobre.
¡Atención!
Emplee sólo conductores de cobre.
Varning!
Använd endast ledare av koppar.
Copyright © 2019, Juniper Networks, Inc.
619
T1600 Core Router Hardware Guide
DC Power Disconnection Warning
WARNING: Before performing any procedures on power supplies, ensure that power is removed from the DC circuit. To ensure that all power is off, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the off position, and tape the switch handle of the circuit breaker in the off position.
Waarschuwing Voordat u een van de onderstaande procedures uitvoert, dient u te controleren of de stroom naar het gelijkstroom circuit uitgeschakeld is. Om u ervan te verzekeren dat alle stroom UIT is geschakeld, kiest u op het schakelbord de stroomverbreker die het gelijkstroom circuit bedient, draait de stroomverbreker naar de UIT positie en plakt de schakelaarhendel van de stroomverbreker met plakband in de UIT positie vast.
Varoitus Varmista, että tasavirtapiirissä ei ole virtaa ennen seuraavien toimenpiteiden suorittamista. Varmistaaksesi, että virta on KATKAISTU täysin, paikanna tasavirrasta huolehtivassa kojetaulussa sijaitseva suojakytkin, käännä suojakytkin KATKAISTU-asentoon ja teippaa suojakytkimen varsi niin, että se pysyy KATKAISTU-asennossa.
Attention Avant de pratiquer l'une quelconque des procédures ci-dessous, vérifier que le circuit en courant continu n'est plus sous tension. Pour en être sûr, localiser le disjoncteur situé sur le panneau de service du circuit en courant continu, placer le disjoncteur en position fermée (OFF) et, à l'aide d'un ruban adhésif, bloquer la poignée du disjoncteur en position OFF.
Warnung Vor Ausführung der folgenden Vorgänge ist sicherzustellen, daß die Gleichstromschaltung keinen Strom erhält. Um sicherzustellen, daß sämtlicher Strom abgestellt ist, machen Sie auf der Schalttafel den
Unterbrecher für die Gleichstromschaltung ausfindig, stellen Sie den
Unterbrecher auf AUS, und kleben Sie den Schaltergriff des Unterbrechers mit Klebeband in der AUS-Stellung fest.
Avvertenza Prima di svolgere una qualsiasi delle procedure seguenti, verificare che il circuito CC non sia alimentato. Per verificare che tutta l'alimentazione sia scollegata (OFF), individuare l'interruttore automatico sul quadro strumenti che alimenta il circuito CC, mettere l'interruttore in posizione OFF e fissarlo con nastro adesivo in tale posizione.
Advarsel Før noen av disse prosedyrene utføres, kontroller at strømmen er frakoblet likestrømkretsen. Sørg for at all strøm er slått AV. Dette gjøres ved
å lokalisere strømbryteren på brytertavlen som betjener likestrømkretsen, slå strømbryteren AV og teipe bryterhåndtaket på strømbryteren i AV-stilling.
Aviso Antes de executar um dos seguintes procedimentos, certifique-se que desligou a fonte de alimentação de energia do circuito de corrente contínua.
Para se assegurar que toda a corrente foi DESLIGADA, localize o disjuntor no painel que serve o circuito de corrente contínua e coloque-o na posição OFF
620 Copyright © 2019, Juniper Networks, Inc.
Chapter 43: Electrical Safety Guidelines and Warnings
(Desligado), segurando nessa posição a manivela do interruptor do disjuntor com fita isoladora.
¡Atención!
Antes de proceder con los siguientes pasos, comprobar que la alimentación del circuito de corriente continua (CC) esté cortada (OFF). Para asegurarse de que toda la alimentación esté cortada (OFF), localizar el interruptor automático en el panel que alimenta al circuito de corriente continua, cambiar el interruptor automático a la posición de Apagado (OFF), y sujetar con cinta la palanca del interruptor automático en posición de
Apagado (OFF).
Varning!
Innan du utför någon av följande procedurer måste du kontrollera att strömförsörjningen till likströmskretsen är bruten. Kontrollera att all strömförsörjning är BRUTEN genom att slå AV det överspänningsskydd som skyddar likströmskretsen och tejpa fast överspänningsskyddets omkopplare i FRÅN-läget.
DC Power Wiring Terminations Warning
WARNING: When stranded wiring is required, use approved wiring terminations, such as closed-loop or spade-type with upturned lugs. These terminations must be the appropriate size for the wires and must clamp both the insulation and conductor.
Waarschuwing Wanneer geslagen bedrading vereist is, dient u bedrading te gebruiken die voorzien is van goedgekeurde aansluitingspunten, zoals het gesloten-lus type of het grijperschop type waarbij de aansluitpunten omhoog wijzen. Deze aansluitpunten dienen de juiste maat voor de draden te hebben en dienen zowel de isolatie als de geleider vast te klemmen.
Varoitus Jos säikeellinen johdin on tarpeen, käytä hyväksyttyä johdinliitäntää, esimerkiksi suljettua silmukkaa tai kourumaista liitäntää, jossa on ylöspäin käännetyt kiinnityskorvat. Tällaisten liitäntöjen tulee olla kooltaan johtimiin sopivia ja niiden tulee puristaa yhteen sekä eristeen että johdinosan.
Attention Quand des fils torsadés sont nécessaires, utiliser des douilles terminales homologuées telles que celles à circuit fermé ou du type à plage ouverte avec cosses rebroussées. Ces douilles terminales doivent être de la taille qui convient aux fils et doivent être refermées sur la gaine isolante et sur le conducteur.
Warnung Wenn Litzenverdrahtung erforderlich ist, sind zugelassene
Verdrahtungsabschlüsse, z.B. Ringoesen oder gabelförmige Kabelschuhe mit nach oben gerichteten Enden zu verwenden. Diese Abschlüsse sollten die angemessene Größe für die Drähte haben und sowohl die Isolierung als auch den Leiter festklemmen.
Copyright © 2019, Juniper Networks, Inc.
621
T1600 Core Router Hardware Guide
Avvertenza Quando occorre usare trecce, usare connettori omologati, come quelli a occhiello o a forcella con linguette rivolte verso l'alto. I connettori devono avere la misura adatta per il cablaggio e devono serrare sia l'isolante che il conduttore.
Advarsel Hvis det er nødvendig med flertrådede ledninger, brukes godkjente ledningsavslutninger, som for eksempel lukket sløyfe eller spadetype med oppoverbøyde kabelsko. Disse avslutningene skal ha riktig størrelse i forhold til ledningene, og skal klemme sammen både isolasjonen og lederen.
Aviso Quando forem requeridas montagens de instalação eléctrica de cabo torcido, use terminações de cabo aprovadas, tais como, terminações de cabo em circuito fechado e planas com terminais de orelha voltados para cima.
Estas terminações de cabo deverão ser do tamanho apropriado para os respectivos cabos, e deverão prender simultaneamente o isolamento e o fio condutor.
¡Atención!
Cuando se necesite hilo trenzado, utilizar terminales para cables homologados, tales como las de tipo "bucle cerrado" o "espada", con las lengüetas de conexión vueltas hacia arriba. Estos terminales deberán ser del tamaño apropiado para los cables que se utilicen, y tendrán que sujetar tanto el aislante como el conductor.
Varning!
När flertrådiga ledningar krävs måste godkända ledningskontakter användas, t.ex. kabelsko av sluten eller öppen typ med uppåtvänd tapp.
Storleken på dessa kontakter måste vara avpassad till ledningarna och måste kunna hålla både isoleringen och ledaren fastklämda.
Related
Documentation
•
General Safety Warnings for Juniper Networks Devices on page 586
•
General Electrical Safety Warnings for Juniper Networks Devices on page 614
Site Electrical Wiring Guidelines for Juniper Networks Devices
•
Distance Limitations for Signaling on page 622
•
Radio Frequency Interference on page 623
•
Electromagnetic Compatibility on page 623
Distance Limitations for Signaling
Improperly installed wires can emit radio interference. In addition, the potential for damage from lightning strikes increases if wires exceed recommended distances or if wires pass between buildings. The electromagnetic pulse (EMP) caused by lightning can damage unshielded conductors and destroy electronic devices. If your site has previously experienced such problems, you might want to consult experts in electrical surge suppression and shielding.
622 Copyright © 2019, Juniper Networks, Inc.
Chapter 43: Electrical Safety Guidelines and Warnings
Radio Frequency Interference
You can reduce or eliminate the emission of radio frequency interference (RFI) from your site wiring by using twisted-pair cable with a good distribution of grounding conductors.
If you must exceed the recommended distances, use a high-quality twisted-pair cable with one ground conductor for each data signal when applicable.
Electromagnetic Compatibility
If your site is susceptible to problems with electromagnetic compatibility (EMC), particularly from lightning or radio transmitters, you might want to seek expert advice.
Strong sources of electromagnetic interference (EMI) can destroy the signal drivers and receivers in the network device and conduct power surges over the lines into the equipment, resulting in an electrical hazard. It is particularly important to provide a properly grounded and shielded environment and to use electrical surge-suppression devices.
CAUTION: To comply with intrabuilding lightning and surge requirements, intrabuilding wiring must be shielded, and the shield for the wiring must be grounded at both ends.
WARNING: The intrabuilding ports of the equipment or subassembly are suitable for connection to intrabuilding or unexposed wiring or cabling only.
The intrabuilding ports of the equipment or subassembly MUST NOT be metallically connected to interfaces that connect to the Outside Plant (OSP) or its wiring. These interfaces are designed for use as intrabuilding interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 4) and require isolation from the exposed OSP cabling. The addition of primary protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring.
Related
Documentation
• General Electrical Safety Guidelines and Electrical Codes for Juniper Networks Devices
Copyright © 2019, Juniper Networks, Inc.
623
T1600 Core Router Hardware Guide
624 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 44
Agency Approvals and Compliance
Statements
•
T1600 Agency Approvals on page 625
•
Compliance Statements for EMC Requirements for Juniper Networks Devices
•
T1600 Compliance Statements for EMC Requirements (European
•
Compliance Statements for EMC Requirements for Juniper Networks Devices
•
Compliance Statements for EMC Requirements for Juniper Networks Devices
•
Compliance Statements for EMC Requirements for Juniper Networks Devices (United
•
Compliance Statements for Environmental Requirements on page 628
•
T1600 Compliance Statements for NEBS on page 628
•
T1600 Compliance Statements for Acoustic Noise on page 628
•
Statements of Volatility for Juniper Network Devices on page 629
T1600 Agency Approvals
The router complies with the following standards:
• Safety
• CAN/CSA-22.2 No. 60950–1–07/UL 60950–1, 2nd Ed., Safety of Information
Technology Equipment
• EN 60825-1 +A1+A2 (1994) Safety of Laser Products - Part 1: Equipment Classification
• EMC
• AS/NZS 3548 Class A (Australia/New Zealand)
• EN55022 Class A (Europe)
Copyright © 2019, Juniper Networks, Inc.
625
T1600 Core Router Hardware Guide
• FCC Part 15 Class A (USA)
• VCCI Class A (Japan)
• Immunity
• EN-61000-3-2 Power Line Harmonics
• EN-61000-3-3 Voltage Fluctuations and Flicker
• EN-61000-4-2 ESD
• EN-61000-4-3 Radiated Immunity
• EN-61000-4-4 EFT
• EN-61000-4-5 Surge
• EN-61000-4-6 Low Frequency Common Immunity
• EN-61000-4-11 Voltage Dips and Sags
• ETSI EN-300386-2 Telecommunication Network Equipment. Electromagnetic
Compatibility Requirements
• NEBS
• GR-1089-Core: EMC and Electrical Safety for Network Telecommunications
Equipment
• SR-3580 NEBS Criteria Levels (Level 3 Compliance)
• GR-63-Core: NEBS, Physical Protection
Related
Documentation
•
T1600 Router Description on page 3
•
T1600 DC Power System Electrical Specifications on page 145
Compliance Statements for EMC Requirements for Juniper Networks Devices (Canada)
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Related
Documentation
•
Compliance Statements for EMC Requirements for Juniper Networks Devices (Israel) on page 627
•
Compliance Statements for EMC Requirements for Juniper Networks Devices (Japan) on page 627
•
Compliance Statements for EMC Requirements for Juniper Networks Devices (United
626 Copyright © 2019, Juniper Networks, Inc.
Chapter 44: Agency Approvals and Compliance Statements
T1600 Compliance Statements for EMC Requirements (European Community)
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Related
Documentation
•
T1600 Agency Approvals on page 625
Compliance Statements for EMC Requirements for Juniper Networks Devices (Israel)
Translation from Hebrew—Warning: This product is Class A. In residential environments, the product may cause radio interference, and in such a situation, the user may be required to take adequate measures.
Related
Documentation
•
Compliance Statements for EMC Requirements for Juniper Networks Devices (Canada) on page 626
•
Compliance Statements for EMC Requirements for Juniper Networks Devices (Japan) on page 627
•
Compliance Statements for EMC Requirements for Juniper Networks Devices (United
Compliance Statements for EMC Requirements for Juniper Networks Devices (Japan)
Related
Documentation
Translation from Japanese—This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. VCCI-A
Copyright © 2019, Juniper Networks, Inc.
627
T1600 Core Router Hardware Guide
Compliance Statements for EMC Requirements for Juniper Networks Devices (United
States)
The hardware equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Related
Documentation
•
Compliance Statements for Environmental Requirements
Batteries in this product are not based on mercury, lead, or cadmium substances. The batteries used in this product are in compliance with EU Directives 91/157/EEC, 93/86/EEC, and 98/101/EEC. The product documentation includes instructional information about the proper method of reclamation and recycling.
T1600 Compliance Statements for NEBS
• The equipment is suitable for installation as part of the Common Bonding Network
(CBN).
• The equipment is suitable for installations in Network Telecommunication Facilities.
• The equipment is suitable for installation in locations where the National Electrical
Code (NEC) applies.
• The battery return connection is to be treated as an isolated DC return (DC-I), as defined in GR-1089-CORE.
• For Juniper systems with AC power supplies, an external surge protective device (SPD) must be used at the AC power source.
Related
Documentation
•
T1600 Agency Approvals on page 625
T1600 Compliance Statements for Acoustic Noise
Maschinenlärminformations-Verordnung - 3. GPSGV, der höchste Schalldruckpegel beträgt 71.2 dB(A) oder weniger gemäss EN ISO 7779
Translation:
The emitted sound pressure resulted in 71.2 dB(A) per EN ISO 7779.
628 Copyright © 2019, Juniper Networks, Inc.
Chapter 44: Agency Approvals and Compliance Statements
Related
Documentation
•
T1600 Router Description on page 3
•
T1600 Physical Specifications on page 139
Statements of Volatility for Juniper Network Devices
A statement of volatility —sometimes known as letter of volatility —identifies the volatile and non-volatile storage components in Juniper Networks devices, and describes how to remove non-volatile storage components from the device.
NOTE: Statements of volatility are not available for all Juniper Networks devices.
CTP series:
• CTP2000
EX series:
• EX2200 and EX2200-C
• EX2300-24P, EX2300-24T, and EX2300-24T-DC
• EX2300-48P and EX2300-48T
• EX2300-C
• EX3300
• EX3400-24P, EX3400-24T, EX3400-24T-DC
• EX3400-48P, EX3400-48T, EX3400-48T-AFI
• EX4200
• EX4300
• EX4300-48MP
• EX4500
• EX4550
• EX4600
• EX8200
• XRE200 External Routing Engine
Copyright © 2019, Juniper Networks, Inc.
629
T1600 Core Router Hardware Guide
LN Series:
• LN1000–CC
MX series:
• M7i
• M7i Compact Forwarding Engine Board (CFEB)
• M40e and M10i
• M320
• MX5, MX10, MX40, and MX80
• MX240, MX480, and MX960
• RE-A-2000 Route Engine
• RE-S-X6-64G Routing Engine
QFX series:
• QFX3008-I
• QFX3100
• QFX3500
• QFX3600
• QFX5100-24Q
• QFX5100-48S
• QFX5100-48T
• QFX5200
• QFX5200-32C
• QFX10008 and QFX10016
SRX series:
• SRX100
• SRX110
• SRX210B
• SRX210H-POE
• SRX210H-P-MGW
• SRX220
• SRX240H
• SRX240H-POE
• SRX300
630 Copyright © 2019, Juniper Networks, Inc.
• SRX320
• SRX340 and SRX345
• SRX550
• SRX650
• SRX1400
• SRX1500
• SRX3400 and SRX3600
• SRX5400, SRX5600, and SRX5800
• SRX-MP-1SERIAL
• SSG-520M
T series:
• RE-A-2000 Route Engine
Chapter 44: Agency Approvals and Compliance Statements
Copyright © 2019, Juniper Networks, Inc.
631
T1600 Core Router Hardware Guide
632 Copyright © 2019, Juniper Networks, Inc.
دانلود
تبلیغات