Utility Raceways model MWD


Add to my manuals
2 Pages

advertisement

Utility Raceways model MWD | Manualzz

Utility Distribution System

Available for Electrical and

Gas Usage

Utility Raceways

M Series

model MWD

Description:

The M-series Raceway is a Utility Distribution System comprised of a stainless steel sheet metal housings enclosing cable bus electrical system and plumbing services that provide connections for individual appliances. Raceways with plumbing services are Listed by Underwriters Laboratories

(UL) as Commercial Appliance Outlet Centers. Raceways with only electrical services are Listed by UL as Multi-outlet

Assemblies. These raceways are intended primarily for use behind a cooking battery, or cooking appliance line-up.

Individual Point-of-use connection plates are located near the top along the length of the raceway.

Peaked Top Shown

Specifications:

Dimensions: Horizontal Chase Width: 6” [generally for plumbing services less than 2” NPT] or 8” [generally for plumbing services 2” NPT or greater], Height: 18” – 30” plus 3-6” peaked top, Length: as required. Service Towers Width: 6-12” Height:

Finished Floor to Exhaust Hood or Finished Ceiling, Length: 18” Nominal to 42” Nominal. Intermediate Pedestals Width: 5-8”

Height: Finished Floor to bottom of Horizontal Chase, Length: 5-8”. Construction: 300-series Stainless Steel. Removable panels held in place with threaded fasteners. Electrical Data: 30 to 150 amperes. 120/208-240 volts. Single- or three-phase. Water:

150 psig & 140° F (60° C) maximum. Gas (Natural gas or LP): 1.25 psig

Standard Features:

• Point-of-use branch circuit protection with receptacle or flexible liquid tight metal conduit (pigtail) mounted adjacent to Point-of-use branch circuit protection on 4.5x12” connection plate. NOTE: For other voltage configurations, consult factory.

• Ground fault circuit interrupter for

15 & 20 amp, 120/1, straight blade

receptacles

• Cable bus

• Copper hot and cold water supply

lines, if required

Optional Accessories:

• Black iron gas supply line, if required

• Black iron steam supply and

condensate return lines, if required

• Quarter-turn shut-off valves on

all individual connections

• Quarter-turn shut-off valves on

main supply valves

• 2” High collar at top of service

tower allows ±1/2” vertical

adjustment to compensate for floor

and/or exhaust hood mounting

irregularities

1055 Mendell Davis Drive, Jackson, MS 39272

888-994-7636, unifiedbrands.net

Please reference our website for the most updated product information and specifications.

Avtec Utility Raceways, Page 2

PP SPEC1046 Rev. A

Revised 11/07

Model MWD

Optional Accessories:

Main electrical service circuit breaker with shunt trip

Quick-disconnect fittings for individual gas connections in addition to quarter-turn shut-off valves for movable appliances

Quick-disconnect fittings for individual water connections in addition to quarter-turn shut-off valves for movable appliances

Vent light switch in service tower

Vent light switch with circuit breaker in service tower

Duplex convenience outlet in service tower(s)

Gas delay reset (GDRI)

120V AC fire-fuel shut-off solenoid valve(s) for gas supply. 1 1/2” And smaller located in service tower(s)

(2” and larger are remotely located)

Temperature/pressure gauge at water incoming service location

Security package (includes):

• exposed fasteners to be tamper-resistant, pin-in-head torx-head, shipped loose and installed in field

• hinged doors equipped with eye for customer-supplied padlock

Panel mounted faucet or pot filler

Flat top in lieu of peaked top on horizontal chase

Ventilation control panel mounted in tower

Filtered water system

Front, Top & Side Views

Front, Top & Side Views

Peaked Top Shown

1055 Mendell Davis Drive, Jackson, MS 39272, 888-994-7636, unifiedbrands.net

© 2009 Unified Brands. All Rights Reserved. DOVER® and the DOVER® Logo are registered trademarks in the United States [and various other countries] of Unified Brands, a wholly-owned subsidiary of Dover Corporation.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement