advertisement
Utility Distribution System
Available for Electrical and
Gas Usage
Utility Raceways
M Series
model MWD
Description:
The M-series Raceway is a Utility Distribution System comprised of a stainless steel sheet metal housings enclosing cable bus electrical system and plumbing services that provide connections for individual appliances. Raceways with plumbing services are Listed by Underwriters Laboratories
(UL) as Commercial Appliance Outlet Centers. Raceways with only electrical services are Listed by UL as Multi-outlet
Assemblies. These raceways are intended primarily for use behind a cooking battery, or cooking appliance line-up.
Individual Point-of-use connection plates are located near the top along the length of the raceway.
Peaked Top Shown
Specifications:
Dimensions: Horizontal Chase Width: 6” [generally for plumbing services less than 2” NPT] or 8” [generally for plumbing services 2” NPT or greater], Height: 18” – 30” plus 3-6” peaked top, Length: as required. Service Towers Width: 6-12” Height:
Finished Floor to Exhaust Hood or Finished Ceiling, Length: 18” Nominal to 42” Nominal. Intermediate Pedestals Width: 5-8”
Height: Finished Floor to bottom of Horizontal Chase, Length: 5-8”. Construction: 300-series Stainless Steel. Removable panels held in place with threaded fasteners. Electrical Data: 30 to 150 amperes. 120/208-240 volts. Single- or three-phase. Water:
150 psig & 140° F (60° C) maximum. Gas (Natural gas or LP): 1.25 psig
Standard Features:
• Point-of-use branch circuit protection with receptacle or flexible liquid tight metal conduit (pigtail) mounted adjacent to Point-of-use branch circuit protection on 4.5x12” connection plate. NOTE: For other voltage configurations, consult factory.
• Ground fault circuit interrupter for
15 & 20 amp, 120/1, straight blade
receptacles
• Cable bus
• Copper hot and cold water supply
lines, if required
Optional Accessories:
• Black iron gas supply line, if required
• Black iron steam supply and
condensate return lines, if required
• Quarter-turn shut-off valves on
all individual connections
• Quarter-turn shut-off valves on
main supply valves
• 2” High collar at top of service
tower allows ±1/2” vertical
adjustment to compensate for floor
and/or exhaust hood mounting
irregularities
1055 Mendell Davis Drive, Jackson, MS 39272
888-994-7636, unifiedbrands.net
Please reference our website for the most updated product information and specifications.
Avtec Utility Raceways, Page 2
PP SPEC1046 Rev. A
Revised 11/07
Model MWD
Optional Accessories:
Main electrical service circuit breaker with shunt trip
Quick-disconnect fittings for individual gas connections in addition to quarter-turn shut-off valves for movable appliances
Quick-disconnect fittings for individual water connections in addition to quarter-turn shut-off valves for movable appliances
Vent light switch in service tower
Vent light switch with circuit breaker in service tower
Duplex convenience outlet in service tower(s)
Gas delay reset (GDRI)
120V AC fire-fuel shut-off solenoid valve(s) for gas supply. 1 1/2” And smaller located in service tower(s)
(2” and larger are remotely located)
Temperature/pressure gauge at water incoming service location
Security package (includes):
• exposed fasteners to be tamper-resistant, pin-in-head torx-head, shipped loose and installed in field
• hinged doors equipped with eye for customer-supplied padlock
Panel mounted faucet or pot filler
Flat top in lieu of peaked top on horizontal chase
Ventilation control panel mounted in tower
Filtered water system
Front, Top & Side Views
Front, Top & Side Views
Peaked Top Shown
1055 Mendell Davis Drive, Jackson, MS 39272, 888-994-7636, unifiedbrands.net
© 2009 Unified Brands. All Rights Reserved. DOVER® and the DOVER® Logo are registered trademarks in the United States [and various other countries] of Unified Brands, a wholly-owned subsidiary of Dover Corporation.