Algas-SDI DFV Series Vaporizing / Mixing Systems Operations & Maintenance Manual
PDF
Dokument
Annons
Annons
...Innovative liquid vaporizing and gas mixing solutions Operations & Maintenance Manual 1140 NW 46 Street, Seattle, Washington, USA 98107 Tel: 206-789-5410 Fax: 206-789-5414 Web: www.algas-sdi.com FILE: MANUAL PN 52681 DFV REV 2-15-04 .DOC WARNING Read the OPERATION MANUAL before operating this equipment. NOTE: Algas-SDI reserves the right to use alternate manufacturers’ components as vendor delivery applicability dictates. Literature contained in the Operation Manual has been supplied by vendors. Please check to be sure supplied data matches your configuration. Contact Algas-SDI if any questions exist. This equipment uses LPG-a flammable fuel, or NH3-a toxic gas, (depending on the model), handled under pressure. Inherent hazards exist and a thorough understanding of the equipment is required to allow safe operation and maintenance. Allow only a TRAINED and FULLY QUALIFIED PERSON to service this equipment. Any time a component must be replaced, use the same type, model , etc. DO NOT SUBSTITUTE! The consequence from such actions are unpredictable and may lead to dire consequences. When components are replaced with components not approved for use in our FM/UL listed equipment, the FM/CSA listing becomes void for that unit. DFV - Direct Fired Packaged Vaporizing / Mixing System Specifications Sheet Refer to Nameplate on unit for the model and voltage information then look up specific information on the tables below. PROPANE 70 / 30 MIX Electrical Specification: 110V / 50-60Hz Amps: 0.6 FUSE PN: 53096, 1-1/2 AMP 220V / 50-60Hz Amps: 0.3 FUSE PN: 53096, 1-1/2 AMP Mixer Specifications: Model / LPGAir Mix Capacity (Millions) * Venturi Stamping Information * Delivery * Venturi High Tank Low Vapor * Motive Pressure Capacity PSIG PSIG Pressure PSIG (Millions) BTU/Hr Kcal/Hr DFV 2.5 - 5 Propane 70/30 2.6 2.7 0.66 0.68 7 6 22 17 2.5 2.5 25 20 4-5 3-4 DFV 2.5 - 8 Propane 70/30 2.8 2.6 0.71 0.66 11 9.5 85 86 2.5 2.5 72 73 8-9 6.5 - 7.5 DFV 7 - 5 Propane 70/30 7.0 7.2 1.76 1.81 8 8 32 24 7 7 43 35 5-6 5-6 DFV 7 - 8 Propane 70/30 7.0 7.0 1.76 1.76 11 9 66 50 7 7 70 54 8-9 6-7 DFV 14 - 5 Propane 70/30 14.0 14.2 3.53 3.58 8 7 51 46 14 14 35 30 5-6 4-5 DFV 14 - 8 Propane 70/30 14.0 14.2 3.53 3.58 11 9.5 76 60 14 14 74 58 8-9 6.5 - 7.5 Vaporizer Specifications: DFV 2.5 1 Direct Fired 40/40 Vaporizer DFV 7 1 Direct Fired 80/40 Vaporizer DFV 14 2 Direct Fired 80/40 Vaporizer Model Capacity (Gal/Hr) Operating Temperature (internal) 40/40H 80/40H 40 80 120 - 160 deg. F Pressure Vessel Rating MAWP 200 PSI @ 650 F MDMT -20F @ 200 PSI Heat Excahnge Surface Area (Sq. FT.) Relief Valve Settting (PSIG) 3.6 7.2 250 Algas-SDI Direct Fired Vaporizer is Factory Mutual Research (FM) Approved . Mixing capacity (BTU/Hr) is directly related to LPG motive pressure. All systems are pre-set at the factory within + 10% of rated motive pressure. Additional field adjustment may be required due to varying operating conditions. Warranty Registration To Register your new equipment: Visit Algas-SDI's web site at: algas-sdi.com, then click on the "Tech Support" button. Select online Registration or print out the Acrobat Warranty Registration. OR Fill out the Warranty Registration information on the last page of this manual. Then make a photo copy and mail to the address shown at the bottom. Warranty, Copyrights and Approvals WARRANTY Algas-SDI International, LLC (ASDI) warrants that the equipment is free of defects in materials and workmanship under normal use and service. ASDI agrees to repair or replace, at our option, without charge f.o.b. factory, any part which has proven defective to the satisfaction of Algas-SDI International, LLC within one (1) year from the date of the original installation or within 18 months from the date of shipment, whichever is earlier. Equipment, which in the opinion of ASDI, has been damaged by improper installation or operation, or has been abused or tampered with in any way, will not be accepted for return under warranty. Algas-SDI International, LLC will not accept back charges for work performed by others upon or in conjunction with ASDI equipment, unless prior authorization is given by means of an Algas-SDI International, LLC purchase order. Algas-SDI International, LLC will not be liable by reason of shutdown, non-operation or increased expense of operation of other equipment, or any other loss or damage of any nature, whether direct or consequential, arising from any cause whatsoever. Algas-SDI International, LLC makes NO other warranty of any kind, whatsoever expressed or implied; and all warranties of merchantability and fitness for a particular purpose are hereby disclaimed by Algas-SDI International, LLC and excluded from these terms of sale. No person has any authority to bind AlgasSDI International, LLC to any representation or warranty other than this warranty. COPYRIGHT Copyright 2000 by Algas-SDI International, LLC, Seattle, Washington 98107. All rights reserved. No part of this manual may be reproduced or copied in any form or by any means, photographic, electronic, or mechanical, without the prior express written consent from Algas-SDI International, LLC, Seattle, Washington, USA. IMPORTANT WARRANTY NOTICE: The Algas-SDI warranty period for equipment is 18 months after shipment from our facility or 12 months after installation. See our warranty statement at the beginning of this manual for the complete text. A warranty registration card has been provided with this manual so that you may register the date of installation for warranty purposes. If you do not return the warranty registration card, the warranty term will be 12 months after the equipment has been shipped to you, the end user. If you do not install it immediately, your warranty may expire earlier than necessary. The warranty registration also gives us information to contact you if we need to send you important information about the equipment later on. Please register your equipment. Symbols and Conventions Special symbols are used to denote hazardous or important information. You should familiarize yourself with their meaning and take special notice of the indicated information. Please read the following explanations thoroughly. GENERAL WARNING OR CAUTION Indicates hazards or unsafe practices which can result in damage to the equipment or cause personal injury. Use care and follow the instructions given. FLAMMABLE GAS HAZARD Indicates a potential hazard which can result in severe personal injury or death. Use extreme care and follow the instructions given. ELECTRICAL DISCONNECT REQUIRED Indicates a potentially dangerous situation which can result in severe personal injury or death or damage to equipment. Use great care and follow the instruction given. ASDI CONTACT NUMBERS If you have questions, need help with your equipment, or want information on other products, contact Algas-SDI at: Telephone: 206.789.5410 Facsimile: 206.789.5414 Email: [email protected] Internet: http://www.algas-sdi.com This page intentionally left blank Table of Contents 1. Introduction Description/Overview Direct Fire Vaporizer Operation 1-1 Mixer Operation 1-1 Figure 1 – DFV Vaporizer / Mixer System Typical Operation 2. Table 1 – Minimum distance requirements from Vaporizer 4. 1-2 Installation DFV System Installation Procedure 3. 1-1 2-3 2-3 Electrical 2-3 LPG Liquid Line 2-4 Figure 2 – Frost on the Liquid Line 2-4 Figure 3 – DFV Installation Drawing 2-5 Burner Supply Line 2-6 Safety Relief Valve 2-6 Table 2 – LPG Liquid Line Sizing Chart (minimum pipe size) 2-6 Table 3 – Equivalent Pipe Length of Various Valves and Fittings 2-6 Table 4 – Liquid Temperature VS. Tank Pressure Chart 2-7 Operation and Startup Vaporizer Operation & Startup 3-9 Mixer Operation and Start-up 3-10 Maintenance Table 5 – Maintenance Schedule 4-12 Adjusting Procedures for System Operating and Safety Controls 4-15 Motive Pressure (Pressure at the Venturi) 4-16 Set Pressure of the Venturi Regulator 4-16 Table 6 – Pressure Requirements & Settings System Delivery Pressure Venturi Pressure Control Switch (Mixed Gas / Delivery Pressure) Table 7 – System Delivery Pressure Set points High Tank Pressure Switch Table 8 – High Tank Pressure Switch Set points 4-16 4-16 4-16 4-16 4-17 4-17 Low Vapor Pressure Switch 4-17 Venturi Check Valve Replacement Instruction 4-18 Figure 4 – Venturi Check Valve Detail 4-18 Figure 5 – Venturi Check Valve Assembly 4-21 Leak Check Procedure for Venturi Check Valves 4-22 BTU Adjustment Procedure 5. 4-22 Troubleshooting Vaporizer 5-23 Pilot 5-23 Main Burner will not ignite 5-23 Drop in Vapor Pressure 5-23 Mixer 5-24 No Reaction when switch turned to ON or RESET 5-24 Vaporizer operates, but Venturi does not Open 5-24 DFV Cycles Once and Shuts Down 5-24 Troubleshooting Tree #1 Pilot will not light 5-24 Troubleshooting Tree #2 Pilot Lights but will not Hold 5-25 Troubleshooting Tree #3 Main Burner will not Light 5-25 Troubleshooting Tree #4 Vapor Service Pressure Drops 5-26 Testing Individual Components 5-27 High Tank (Mixed Gas) Pressure Safety Switch 5-27 Replacing the High Tank (Mixed Gas) Pressure Switch 5-27 Low Vapor Safety Switch 5-28 Replacing the Low Vapor Safety Switch 5-28 Venturi Pressure Control Switch (Mixed Gas/Delivery) 5-28 Replacing the Venturi Pressure Control Switch (Mixed Gas/Delivery) 5-28 Solenoid Valve Electrical Test 5-29 Figure 6 – Solenoid Valve Electrical Test 5-29 Appendix A: Component Information Table 12 – DFV Packaged Vaporizing / Mixing System Recommended Spare Parts And Accessories Appendix B: Drawings & Technical Information Equipment Drawings DFV 2.5 DFV 7 DFV 14 Electrical Drawings DFV 14 Warranty Registration Refer to the nameplate on the unit to fill out the product registration. Then Photo copy and mail to address shown. Or register on line by visiting Algas-SDI web site under "Tech Support". Introduction 1 The DFV Liquefied Petroleum Gas (LPG) vaporizing/mixing systems from AlgasSDI are self-contained units providing a mixture of LPG gas and air, which can replace natural gas. An accumulator tank enables the venturi to cycle on and off to meet the required load. Operation is quiet, reliable, and safe. Description/Overview The DFV compact LPG vaporizer/mixer systems are available in various propane models providing a gas/air mix from 2.5 to 14 million BTU at pressures from 5 to 8 PSIG depending on the model selected. The gas/air provided is compatible with natural gas systems and may be used as a direct replacement without adjustments to your burner systems. This combination system uses the Algas-SDI Direct Fired vaporizer to vaporize the LPG and the Algas-SDI atmospheric venturi system. The gas is mixed with air and stored in the accumulator tank to provide uninterrupted flow of mixed gas from full flow to no flow, automatically. Power requirements for the DFV are 110V/50-60Hz or 220V/50-60Hz. A liquid pump, such as the Algas-SDI Stabilaire pump system, may be required to provide sufficient gas pressure for the mixing process. The required pressure for your system is indicated on the data sheet in Appendix B of this manual. If your supply tank will not provide the required pressure under all expected temperature conditions, a pump will be needed Direct Fire Vaporizer Operation The Algas-SDI Direct Fired vaporizer applies an open flame directly to the heat exchange surface, which contacts the LPG liquid that is to be vaporized. The outlet LPG vapor temperature of the vaporizer can be set using the thermostat. This controls the burner(s) cycling on and off to accommodate the load requirement. The Liquid Inlet valve and the Capacity Control valve provide safety against liquid carry-over. Refer to the Operation section for details. Mixer Operation The pressure of the vaporized LPG from the vaporizer closes the low vapor switch and activates the venturi control circuit. The venturi solenoid opens, feeding LPG vapor through a pressure regulator and then through the venturi nozzle. The LPG creates a pressure lower than atmospheric pressure in the venturi housing as it exits the venturi nozzle. The air and the LPG streams are mixed and compressed in the diffuser section and pressurize the accumulator tank. When the pressure in the accumulator tank reaches a preset level, the venturi solenoid valve closes. As the mixed gas is used, the pressure decreases in the accumulator tank. Thus closing the venturi control switch and opening the solenoid valve to refill the tank. Algas–SDI Operations and Maintenance Manual – DFV – P/N: 52681 1-1 Introduction Figure 1 – DFV Vaporizer / Mixer System Typical Operation Vapor AIR AIR WARNING DISCONNECT THE SUPPLY CIRCUIT BEFORE SERVICING TO PREVENT INJURY FROM ELECTRICAL SHOCK P/N 50833 Liquid Vaporizer DFV MANUAL FIG. 1.DWG 1-2 1. OFF/0N/RESET SWITCH 10. HEAT EXCHANGER 2. LOW VAPOR PRESSURE SWITCH 11. SAFETY SOLENOID VALVE 3. HIGH TANK PRESSURE SWITCH 12. VENTURI VAPOR SOLENOID VALVE 4. VENTURI PRESSURE CONTROL SWITCH (MIXED GAS) 13. VENTURI VAPOR PRESSURE REGULATOR 5. INLET VALVE 14. VENTURI HOUSING ASSEMBLY 6. CAPACITY CONTROL VALVE 15. VENTURI NOZZLE 7. BURNER SUPPLY REGULATOR 16. DIFFUSER 8. THERMOSTAT 17. ACCUMULATOR TANK 9. BURNER 18. INLET STRAINER Algas–SDI Operations and Maintenance Manual – DFV – P/N: 52681 2 Installation DFV System Installation Procedure The DFV systems are normally installed outside of plant buildings on a concrete pad. Consult state, provincial, insurance carriers, and local authorities for installation requirements. Table 1 provides information on installation distances. Install the system on a level base and secure it through the four mounting holes. Use 1/2“, grade 5 “J” bolts embedded in a concrete pad at least 6’ x 10’ x 8” thick. Install a drain valve in the plugged opening at the bottom of the surge tank. Install a manual valve after the mixed gas outlet. See Figure 3 for suggested installation Clean all foreign materials from all pipe lines prior to making final connections. All joints require a pipe sealant approved for LPG. Test for leaks using an inert gas, such as compressed carbon dioxide or nitrogen, at approximately 100 psig (7 2 kg/cm ). Check all connections using an appropriate leak detection solution or device. Even very small leaks are unacceptable! Eliminate all leaks prior to operation. Table 1 – Minimum Distance Requirements from Vaporizer Exposure Storage Tank Storage tank shutoff valves Point of transfer Nearest important building or group of buildings or line of adjoining property which maybe built upon (except buildings in which vaporizer is installed). Minimum Distance From Vaporizer Required 10 feet 15 feet 15 feet 25 feet * Reference NFPA58 ELECTRICAL The data sheet provides electrical power information and addition equipment specifications. Install the vaporizer and circuit breaker in accordance with applicable NFPA, NEC and local regulations. Appropriately ground the vaporizer as specified by local regulations. Algas–SDI Operations and Maintenance Manual – DFV – P/N: 52681 2-3 Installation LIQUID LINE The liquid line from the storage tank to the vaporizer should be of sufficient size to supply the vaporizer at full capacity with a maximum pressure drop of less than the hydrostatic head pressure (see NFPA 54). Refer to Tables 2 & 3 for line sizing information. An adequately sized 60 mesh strainer (provided) must be installed at the liquid inlet to the vaporizer. Also install an isolation valve with hydrostatic relief on the inlet liquid line before the strainer Connect the liquid LPG line to the vaporizer inlet. Back flow of liquid from the vaporizer toward the tank is part of the normal operation of the vaporizer. Do not install check valves in that line. Pressure in the LPG storage tank depends on ambient temperature. Install an Algas-SDI Stabilaire liquid pump beneath the storage tank if the lowest ambient temperature will not provide enough pressure from the tank to supply your specific system. Refer to the data sheet provided in Appendix B of this manual to determine the pressure required for your specific system. The pump should be set up to supply LPG at a constant pressure, regardless of the flow rate. Figure 2 – Frost on the Liquid Line Frost.wmf NOTE Frost on the liquid line indicates propane is vaporizing due to a restriction that causes a pressure drop. If the inlet pipe is too small, the LPG vaporizes before it enters the vaporizer causing a drastic drop in efficiency. Wrong size inlet pipes can reduce output as much as 50%. When referring to the line sizing chart, note that the pipe sizes recommended are minimum size. Restrictive valves or other devices may also cause a pressure drop in the liquid line resulting in a frosting of the line. If pressure drop is excessive a liquid pump may be required. 2-4 Algas–SDI Operations and Maintenance Manual – DFV – P/N: 52681 Installation WARNING Algas–SDI Operations and Maintenance Manual – DFV – P/N: 52681 DISCONNECT THE SUPPLY CIRCUIT BEFORE SERVICING TO PREVENT INJURY FROM ELECTRICAL SHOCK P/N 50833 Figure 3 – DFV Installation Drawing 2-5 Installation BURNER SUPPLY LINE The vaporizer burners are supplied with vapor from the outlet of the vaporizer where the least possibility of condensation will take place. However, in regions where there is a problem with a high content of heavy ends in the LP gas, a separate vapor supply line to the burner control on the vaporizer may be installed. If a separate burner supply line is used, the following is recommended: 1. Disconnect the ¼” line at the burner regulator. 2. Disconnect the ¼” line at the tee on top of the heat exchanger and plug it with ¼ NPT plug. 3. Install a first stage regulator as close to the tank vapor outlet as possible. A manual shut-off valve should be installed ahead of the regulator. 4. Connect the supply line from the first stage regulator to the burner regulator at the vaporizer. make sure that the supply is sized properly to handle maximum input rating of the vaporizer burner(s). 5. Adjust the burner regulator at the vaporizer so that the vapor pressure at the burner is 11” WC. SAFETY RELIEF VALVE Always install the raincap or similar device (if removed) to prevent water and other debris from entering the relief valve discharge port. If water enters, it may freeze and prevent the relief valve from proper discharge, creating a potentially hazardous situation Table 2 – LPG Liquid Line Sizing Chart (minimum pipe size) System Size DFV 2.5 DFV 7.0 DFV 14.0 25 ¾” ¾” 1” 50 ¾” ¾” 1¼” Distance in feet from storage to vaporizer 75 100 150 200 1” 1” 1” 1¼” 1” 1” 1” 1¼” 1¼” 1¼” 1¼” 1½” 300 1¼” 1¼” 1½” 400 1¼” 1¼” 1½” * Add equivalent length of all values and fittings to the length of pipe. Use this value from these tables to determine minimum pipe use. Table 3 – Equivalent Pipe Length of Various Valves and Fittings (length in feet) Size/Description Globe Valve Gate Valve Angle Valve Elbow, 90 Elbow, 45 Elbow, 90 STR Tee 2-6 ½” 15.5 0.6 8 1.4 0.7 2.3 2.7 ¾” 21 0.8 11 1.9 1 3.1 3.7 1” 27 1 14 2.4 1.2 4 4.8 1 ¼” 36 1.4 18 3.2 1.6 5.3 6.4 1 ½” 43 1.6 21 3.8 2 6.3 7.5 Algas–SDI Operations and Maintenance Manual – DFV – P/N: 52681 Installation Table 4 – Liquid Temperature vs. Tank Pressure Chart Propane Tank Gauge Pressure Liquid Temperature °F °C PSI Kpa -43.7 -40 -30 -41.6 -39.6 -36.8 0 1.4 3.4 0 9.6 23.6 -30 -25 -20 -15 -10 -34.1 -31.3 -28.6 -25.8 -23.1 5.6 8.1 10.7 13.6 16.7 38.9 55.6 73.7 93.5 114.9 -5 0 5 10 15 -20.3 -17.6 -14.8 -12.1 -9.3 20.0 23.6 27.5 31.7 36.2 136.1 163.1 189.9 218.9 249.9 20 25 30 35 40 -6.6 -3.8 -1.1 1.6 4.4 41.1 46.2 51.7 57.6 63.8 283.1 318.7 356.7 397.0 440.1 45 50 55 60 65 7.1 9.9 12.6 15.4 18.1 70.5 77.5 84.9 92.8 101.2 485.8 534.3 585.7 640.1 697.6 70 75 80 85 90 20.9 23.6 26.4 29.1 31.9 109.9 119.3 129.1 139.7 150.2 758.3 822.4 889.9 963.4 1035.7 95 100 105 110 115 34.6 37.4 40.1 42.9 45.6 161.6 173.6 186.1 199.2 213.0 1114.2 1196.6 1283.1 1373.7 1468.6 120 125 130 135 48.4 51.1 53.9 56.6 227.4 242.5 258.2 274.7 1567.9 1671.9 1780.5 1893.9 Algas–SDI Operations and Maintenance Manual – DFV – P/N: 52681 2-7 Installation This page left intentionally blank 2-8 Algas–SDI Operations and Maintenance Manual – DFV – P/N: 52681 Operation and Startup 3 WARNING Do not apply power to unit if LPG fumes are present. They may ignite! Keep a fire extinguisher available in the immediate vicinity before re-applying power when the control cover is removed. CAUTION Piping may be hot! DFV normal operating temperature is about 500-600°F [260-315°C] near the Direct Fire vaporizer exhaust stack. Piping may approach this temperature under some conditions. FOR YOUR SAFETY — IF YOU SMELL GAS: n DO NOT TOUCH ANY ELECTRICAL SWITCHES. n EXTINGUISH ANY OPEN FLAME. n SHUT OFF GAS SUPPLY IMMEDIATELY. n SHUT OFF POWER THROUGH A REMOTE DISCO Vaporizer Operation & Startup Refer to Direct Fired Vaporizer Manual for Operation, Startup, Maintenance, Troubleshooting, Spare parts and diagrams. Algas–SDI Operations and Maintenance Manual – DFV – P/N: 52681 3-9 Operation and Startup Mixer Operation & Start-Up 1. Complete installation and leak test. 2. Turn on the customer provided DISCONNECT for the equipment. 3. Turn the OFF/ON/RESET SWITCH to the OFF position. 4. Check for correct VOLTAGE to the system. 5. Manually close the MIXED GAS OUTLET VALVE, which is located at the outlet of the accumulator tank. 6. Manually close VENTURI ISOLATION VALVE(S), which is located after the outlet of the vaporizer NOTE Operating the unit in a “dry” condition will not damage this unit. It is not necessary to have LPG in the unit for testing or evaluation. 7. Drain the ACCUMULATOR TANK, check that no moisture or oils are present, re-close the valve. 8. Open all valves between the LPG storage tank and the vaporizer to allow liquid flow to the vaporizer. If a pump is required to achieve the necessary vapor pressure, start the pump and check the outlet pressure. Refer to the data sheet in Appendix B for required vapor pressure. 9. Start Vaporizer. Refer to Vaporizer Operation & Start-up section in the Direct Fired Manual for details. 10. Open the VENTURI ISOLATION VALVE(S). 11. Check the VAPOR PRESSURE GAUGE to verify the proper LPG vapor pressure. 12. Turn the OFF/ON/RESET SWITCH to the ON position. Then turn the switch to the RESET position to allow the venturi to start cycling. 13. The venturi will cycle, raising the pressure in the mixed gas accumulator to the preset level. The unit is now ready to supply mixed gas and opening the outlet shutoff valve will allow mixed gas to flow. The burner(s) and venturi(s) will cycle automatically to match flow conditions while the accumulator tank will insure continuous mixed gas supply. 14. Refer to BTU adjustment procedure in the maintenance section for proper method for setting the venturi trains. The pressure has been set initially at the factory; however, slight adjustments may be required due to altitude or vibrations from shipping. 15. The system is now ready for operation. 16. Refer to the Troubleshooting section for any problems. 3-10 Algas–SDI Operations and Maintenance Manual – DFV – P/N :52681 Maintenance 4 The DFV packaged vaporizing/mixing system is designed for long term troublefree operation. Considering the nature of system use, with heavy prolonged workloads, it is very important to provide scheduled maintenance. The following maintenance schedule may be used as a guideline. This maintenance schedule includes items that must be serviced, the type of service to perform, and the frequency of service. However, this is only a suggested schedule. The conditions in your area and quality of the LP gas liquid may dictate a more stringent or more lax maintenance, but whatever your schedule, remember that maintenance is of paramount importance for trouble free operation. ASDI provides a RECOMMENDED SPARE PARTS list located at the back of this manual and the Direct Fired manual for ordering ease when replacing components. CAUTION The equipment described in this manual is designed to operate with LP gas, a flammable fuel under pressure. The nature of the application involves inherent hazards that could result in injury. ONLY a trained and fully qualified person should service this equipment. CAUTION 1. When servicing a component in the liquid or vapor line. BE SURE that the LP-gas supply to that component is shut off before it is removed or disassembled. The vaporizer must be completely blown down before performing service. Be sure that ALL sources of ignition are extinguished within 25 feet of the work area. 2. When flaring the contents of the vaporizer, be sure that the burners are on to prevent freezing during the flaring operation. Algas–SDI Operations and Maintenance Manual – DFV – P/N: 52681 4-11 Maintenance Table 5 – Maintenance Schedule Item 1 Month 3 Months 6 Months Annual Inspect pilot assembly. The flame should Pilot Burner Assembly envelope 3/8” to ½” of the thermocouple tip. Inspect for proper flame. Check that air supply openings Main Burner Assembly are clear of debris, dirt or trash. If needed, clean each burner orifice. Safety Relief Valves Check all relief valves on vaporizer, accumulator tank, liquid, and vapor lines for signs of corrosion in outlet. Check all raincaps. Replace if damaged or missing. Enclosure Check access door and inside enclosure for debris and combustible material. Check and, if needed, clean the inlet louvers and vent cap(s). 4-12 Inspect for proper flame. Check that air supply openings are clear of debris, dirt or trash. If needed, clean each burner orifice. Algas–SDI Operations and Maintenance Manual – DFV – P/N: 52681 Maintenance Item 1 Month 3 Months 6 Months Annual Thermostat Check the thermostat for proper operation (see Start-up Procedure). If the thermostat is not operating properly, it should be replaced (the thermostat cannot be serviced). Thermocouple The electrical output of the thermocouple should be checked with a millivolt meter. The thermocouple output should be between 13 and 30 millivolts. A lower than 13 millivolt reading indicates the thermocouple (P/N 46/4) should be replaced. Liquid Inlet Valve Disassemble and clean the valve. To service valve, use kit 3-0016 Capacity Control Valve Disassemble and clean the valve. To service valve, use kit 3-0017. Use powdered graphite as lubricant around top of the piston with “O” ring. Use grease as lubricant on “O” ring. Algas–SDI Operations and Maintenance Manual – DFV – P/N: 52681 4-13 Maintenance Item Liquid LPG inlet strainer 1 Month 3 Months 6 Months Annual Check as conditions Check as conditions require require Clean Change the diaphragm and operating parts if the unit is being used regularly or if the valve makes unusual noises (i.e. buzzing, etc.) during operation. See the enclosed maintenance and operation sheet for ASCO 2-way valves replacement procedure. (Appendix A) Solenoid valve Visually inspect for corrosion, loose wires, Check primary terminal lug tension heat buildup and charring Electric wiring and connections Low vapor pressure switch set points Verify against the values on the data sheet High tank pressure switch set points Verify against the values on the data sheet Venturi check valve assembly Check clevis assy., Check for wear and clevis pivot screw, valve leakage arm & valve surface for wear. Replace if worn. Check for leaks Motive pressure (pressure at the venturi) set point Check setting NOTE Before replacing thermostat, be sure thermocouple is delivering the proper voltage to the thermostat (13 to 30 millivolts). 4-14 Algas–SDI Operations and Maintenance Manual – DFV – P/N: 52681 Maintenance Adjustment Procedures for System Operating and Safety Controls All of the controls (except for the venturi regulator) are preset at the factory. However, vibration in transportation may alter the settings or it may be desirable to change the system delivery pressure (within the range of the installed venturi). Thus the control settings may need to be checked or readjusted. Any replaced controls will also require adjustment. WARNING Power to the control box must be turned off at a remote disconnect before the cover is removed. Check for propane leaks before applying power. WARNING DO NOT APPLY POWER IF LPG FUMES ARE PRESENT. THEY MAY IGNITE! WARNING DO NOT attempt to adjust the pressure switches with the power turned on. WARNING Always have a fire extinguisher handy when operating with the control enclosure open. Algas–SDI Operations and Maintenance Manual – DFV – P/N: 52681 4-15 Maintenance MOTIVE PRESSURE (Pressure at the Venturi) SET PRESSURE OF THE VENTURI REGULATOR The initial motive pressure for the venturi is stamped on the base of the venturi housing. This pressure is adjusted using the vapor pressure regulator on the LPG vapor train. The adjustments should be made with the system in operation, using a BTU METER while adjusting the motive pressure and monitoring BTU meter to attain a 1450 BTU/cu. ft. mix. Table 6 – Pressure Requirements & Settings Propane Pressure Requirement Data Mixed air/propane *Nozzle motive Inlet vapor pressure delivery pressure psig (kg/cm2) pressure psig (kg/cm2) psig (kg/cm2) 5.0 (.35) 31.0-55.0 (2.18-3.87) 28.0-43.0 (1.97-3.02) 8.0 (.56) 74.0-85.0 (5.20-5.98) 70.0-74.0 (4.92-5.20) SYSTEM DELIVERY PRESSURE VENTURI PRESSURE CONTROL SWITCH (MIXED GAS / DELIVERY PRESSURE) The Venturi Pressure Control Switch (Mixed Gas/Delivery) is wired normally closed and is set to open according to the set point on the data sheet. The Venturi Pressure Control Switch will cycle on and off as the tank pressure changes. The system delivery pressure is adjustable within the range of the installed venturi. The on/off and differential pressures are set by means of the Venturi Pressure Control Switch adjustment screw and the Venturi Pressure Control Switch differential pressure adjustment wheel. To adjust the switch, use a 1/4“ open end wrench. Turn the main adjustment screw counterclockwise to lower the setpoint or clockwise to raise the setpoint. Turn the adjusting screw until the “ON” setpoint is reached, then set the differential adjustment wheel for a deadband "OFF" of .75 to 1 psi. A typical setting is between E and F. See Section 5: Troubleshooting for replacing the Venturi Pressure Control Switch. Table 7 – System Delivery Pressure Set points Delivery Pressure #5 #8 4-16 System Delivery Pressure Set points DFV 2.5 - DFV 14.0 Venturi “OFF” Venturi “ON” (psig) Deadband (psig) 5 5¾-6 .75 - 1 8 8¾-9 .75 - 1 Deadband Position E-F E-F Algas–SDI Operations and Maintenance Manual – DFV – P/N: 52681 Maintenance HIGH TANK PRESSURE SWITCH The High Tank Pressure Switch is wired normally closed and is set to open according to the set point on the data sheet. The high tank pressure switch is a safety that opens due to high tank pressure. When this occurs it is an indication that there is a component failure. See Troubleshooting Section to resolve the problem. The pressure switch is located in the control box. To set, turn the adjusting wheel to approximate the setting shown on the indicator scale on the switch. The set points for the high tank pressure switch in the control box are as follows. Table 8 – High Tank Pressure Switch Set points High Tank Pressure Switch Set points Mixed air/propane delivery pressure High tank pressure switch 5 psig 8 psig 8 psig 11 psig LOW VAPOR PRESSURE SWITCH The Low Vapor Pressure Switch is wired normally open and is set according to the set point on the data sheet. The Low Vapor Pressure Switch opens when there is in adequate pressure to operate the venturi. With the system operating, slowly throttle the vaporizer LPG vapor outlet valve. This reduces the LPG vapor pressure being sent to the mixer. Observe the LPG vapor pressure gauge and note the pressure at which the low vapor pressure switch opens and disables the venturi solenoid valve. To set the low vapor pressure switch, turn the adjusting wheel to the approximate setting shown on the indicator scale on the switch body. Refer to the data sheet for set point information. Repeat the process to verify the setpoint. Note the low vapor pressure switch only disables the venturi solenoid valve and does not shut off the DFV. Algas–SDI Operations and Maintenance Manual – DFV – P/N: 52681 4-17 Maintenance Venturi Check Valve Replacement Instruction If the venturi check valve leaks or the pivot mechanism operates poorly, the venturi check valve assembly must be replaced. Follow the procedure below to replace the venturi check valve and pivot arm. NOTE As with all components containing materials subject to deterioration, the venturi check valves should routinely be checked and replaced as necessary. A minimum annual inspection should be conducted. IF REPLACEMENT VENTURI CHECK VALVE IS NOT ASSEMBLED, follow below instructions This instruction set is to be used for the Venturi Check Valve KitP/N - 40490. 1. After the existing check valve (A) has been removed, examine the machined seating surface (F) on the venturi housing (D) to be sure the surface is clean and without flaws. 2. Screw the clevis (I) into the housing, using Permatex NO. 2 or equivalent on the threads, until 3- 3 ½ threads are exposed outside of the housing (D). Do not use a screwdriver or other prying device to install the clevis. Clean any excess Peratex from clevis slot. 3. Insert the check valve arm (K) into the slot of the clevis and connect the two pieces with the clevis/arm pivot screw (L) through the aligned holes. Be sure that the lock washer and a flat washer are inserted on the lock nut end (with the flat washers are inserted on either side of the clevis. Tighten the lock nut (J), allowing for free swing of the arm. 4-18 Algas–SDI Operations and Maintenance Manual – DFV – P/N: 52681 Maintenance Check for proper clevis installation as follows: n With the arm (K) raised, rotate the valve (M) around the valve/arm pivot so that the edge of the valve nearest the clevis is lowered without allowing the valve (M) to turn around the valve/arm pivot; only the lower part of the valve should contact the seating surface (F). With the valve (M) rotated to the other extreme position around the valve/arm pivot, lowering the arm (K) should cause only the upper part of the valve (M) to contact the seating surface (F). n Lower the arm (K) a third time, allowing free rotation of the valve (A). The valve (M) should be able to contact the seating surface (F) uniformly all around. Algas–SDI Operations and Maintenance Manual – DFV – P/N: 52681 4-19 Maintenance n If the valve does not contact the seat as described above, reposition the clevis (I) in the housing (D). At least three threads must be exposed for proper installation of the acorn nut (G) 5. Place sealing washer (H) on to clevis (I) then tighten the acorn nut (G) onto the clevis (I) outside the housing (D), making sure that when the nut is tight , the valve is centered. Do not use any tools on the clevis inside the housing, or on the arm or valve. It may be helpful to start with the valve offset to the side and allow it it to rotate to its centered position while tightening the acorn nut. 6. Tighten the lock nut (J) on the clevis/arm pivot screw until the arm is tight in the clevis. Then slowly loosen the lock nut just until the arm can swing freely. Check that the valve is centered and clears the housing on both sides. 7. Install the venturi housing lid (B), using a new gasket (C). Apply white Lithium grease to gasket & threads. 8. Apply pressure to the unit and check for leaks around the lid and around the check valve. Initially a small leak may occur around the check valve, but after a few cycles the leak should correct itself. If it persists, remove the lid and recheck the seating surfaces and the alignment. 4-20 Algas–SDI Operations and Maintenance Manual – DFV – P/N: 52681 Maintenance Figure 5 –Venturi Check Valve Assembly Venturi Check Valve.dxf A. Flapper Arm Assembly F. Seating Surface K. Flapper Arm B. Housing Lid G. Acorn Nut L. Pivot Screw C. Housing Gasket H. Sealing Washer M. Flapper D. Housing I. Clevis E. Diffuse/Housing “O” Ring J. Lock Nut Algas–SDI Operations and Maintenance Manual – DFV – P/N: 52681 4-21 Maintenance LEAK CHECK PROCEDURE FOR VENTURI CHECK VALVES Remove silencer from venturi. Build up pressure in the surge tank to the system operating pressure, shut off the system, close the inlet valve, and disconnect all power. Use either a gas detector or a soapy solution applied to the check valve and seat to determine if there is a leak. If there is a slight leak from the venturi check valve, tapping the valve open quickly with the handle of a screwdriver (DO NOT USE THE BLADE SIDE) or a suitable tool may dislodge a small particle on the lip of the valve. Otherwise the venturi must be disassembled to adjust the check valve pivot arm as outlined in the previous procedure. When assembling the silencer into the venturi housing, use an anti-seize compound on the threads. WARNING LPG is heavier than air and LPG vapor either mixed with or without air will “pool” in low areas without ventilation or wind. Check potential pooling areas with a gas detector if gas is suspected. BTU ADJUSTMENT PROCEDURE The BTU adjustment procedure must be done on initial start-up to assure proper mixed gas BTU value. Connect your BTU analyzer to the surge tank test port. With your system running, establish a load such that the venturi is on 50% of the time and off 50% of the time. Adjust the venturi regulator until the venturi motive pressure is at the pressure stamped on the venturi housing or the pressure called out on your data sheet. This is a starting point for adjusting the BTU value of your mixed gas. Monitor your BTU instrument and set the venturi regulator until you have the appropriate mix of propane/air (in most cases 1450 BTU’s per cubic foot, or 1.30 specific gravity). Due to the physical properties of the venturi’s, as the motive pressure increases, the LPG flow increases accordingly. If the motive pressure is set too high, it may overdraw the vaporizer. A general rule is, do not exceed the motive pressure stamped on the venturi housing by more than 5 PSIG. Increase the system load and verify the mixed gas BTU value. Disconnect your test equipment and return the system to operation 4-22 Algas–SDI Operations and Maintenance Manual – DFV – P/N: 52681 Troubleshooting 5 VAPORIZER There are 4 troubleshooting trees provided for the Direct Fire Vaporizer. TREE #1 - Pilot will not light. TREE #2 - Pilot lights but will not hold. TREE #3 - Main Burner will not light. TREE #4 - Vapor Pressure Drops. PILOT The pilot flame is adjusted at the factory to provide a non-blowing blue flame. If the flame is not adequate or the pilot does not stay lit, check the pilot burner to see if it is clear of any obstructions. Flame should envelope 3/8” to ½“ of the thermocouple tip. If the burner is too low, the thermocouple will not generate sufficient voltage to hold the main burner’s valve open. If the pilot flame is too small, clean the pilot burner orifice, or replace the pilot. MAIN BURNTER WILL NOT IGNITE Check the pilot burner as per 1 above. Check burner regulator. Disconnect tube from outlet side of regulator and check output pressure. If pilot burner and burner regulator check out OK, the problem is in the thermostat. Replace thermostat (the main burner will not come on unless the temperature in the heat exchanger falls below 120° F). DROP IN VAPOR PRESSURE Check burner; check pilot as per 1 and 2 above. If vapor pressure drops, but main burner(s) is working, vapor demand exceeds vaporizer capacity. Cut down on vapor demand. Check liquid excess flow valve and shut off valve; make sure they are open. Close liquid inlet valve upstream of strainer. Bleed down system and clean strainer filter. AlgasSDI Operations and Maintenance Manual – DFV – P/N: 52681 5-23 Troubleshooting MIXER No Reaction when switch turned to ON or RESET Be sure wiring is correct. Refer to the Wiring Schematic for proper installation. Replace switch if defective. Vaporizer operates, but Venturi does not Open Hold the OFF/ON/RESET switch in the RESET position to energize the relay. If the solenoid valves still do not open, check the continuity of the solenoid circuit. Replace wire or solenoid valve is continuity is open. Check the wiring as well. The pressure switches may need adjustment or replacement. Refer to the Testing Individual Components section for details. DFV Cycles Once and Shuts Down Check the mixed gas pressure. Adjust the VENTURI PRESSURE CONTROL SWITCH if the pressure is too high. Refer to the Testing Individual Components section for details. 5-24 AlgasSDI Operations and Maintenance Manual – DFV – P/N: 52681 Troubleshooting AlgasSDI Operations and Maintenance Manual – DFV – P/N: 52681 5-25 Troubleshooting 5-26 AlgasSDI Operations and Maintenance Manual – DFV – P/N: 52681 Troubleshooting Testing Individual Components NOTE See ADJUSTMENT PROCEDURES FOR SYSTEM OPERATING AND SAFETY CONTROLS section. Venturi Pressure Control Switch, earlier in this manual for additional information. HIGH TANK PRESSURE SAFETY SWITCH Shuts off the unit when the MIXED GAS pressure is too high due to a malfunction in the control system. See the data sheet for pressure setting. The pressure is adjusted by turning the adjustment dial on the switch. Accuracy of the High Tank Pressure safety switch can be checked with an external regulator and calibrated pressure. REPLACING THE HIGH TANK PRESSURE SAFETY SWITCH n Turn power off at the disconnect, bleed the system to 0 pressure. n Remove the wires to the switch. n Remove the switch with an open end wrench. n Install a new switch. n Turn power on, open isolation valve, and bring system up to operating pressure. n Carefully check carefully for leaks at all connections. n Refer to the adjustment procedure section for setting the switch. AlgasSDI Operations and Maintenance Manual – DFV – P/N: 52681 5-27 Troubleshooting LOW VAPOR SAFETY SWITCH Disables the venturi when the vapor pressure is too low to properly operate the venturi. Once there is adequate vapor pressure the venturi will resume operation as needed. See the data sheet for pressure setting. The pressure is adjusted by turning the adjustment dial on the switch. Accuracy of the low vapor safety switch can be checked with an external regulator and calibrated pressure gauge or by removing the switch and testing it with a known pressure. REPLACING THE LOW VAPOR SAFETY SWITCH n Turn off the power at the disconnect, bleed the system to 0 pressure. n Remove the wires to the switch. n Remove the switch with an open end wrench. n Install a new switch. n Turn power on, open isolation valve and bring system up to operating pressure. n Refer to the adjustment procedures section for setting the switch VENTURI PRESSURE CONTROL SWITCH ( MIXED GAS / DELIVERY PRESSURE ) The Venturi Pressure Control Switch maintains tank pressure by cycling on and off as required by the load. Accuracy of the Venturi Pressure Control switch can be checked with an external regulator and calibrated pressure. REPLACING THE VENTURI PRESSURE CONTROL SWITCH ( MIXED GAS / DELIVERY PRESSURE ) 5-28 n Turn off the power at the disconnect, close the inlet hand valve and bleed the system to 0 pressure. n Remove the wires to the switch. n Remove the switch with an open end wrench. n Install a new switch. n Turn power on, open isolation valve and bring system up to operating pressure. n Verify operation with external pressure gauges. n Refer to the adjustment procedures section for setting the switch. AlgasSDI Operations and Maintenance Manual – DFV – P/N: 52681 Troubleshooting Solenoid Valve Electrical Test WARNING Shut off power at the electrical disconnect before proceeding. Remove the cover of the conduit tee near the solenoid valves. Disconnect the wires and measure each of the solenoid lead wires. You should measure approximately 3 ohms on the multimeter. If the measured resistance is incorrect, change the solenoid coil. Figure 6 – Solenoid Valve Electrical Test. AlgasSDI Operations and Maintenance Manual – DFV – P/N: 52681 5-29 Troubleshooting 5-30 AlgasSDI Operations and Maintenance Manual – DFV – P/N: 52681 APPENDIX A COMPONENT INFORMATION This page intentionally left blank. Appendix A Table 12 – DFV Packaged Vaporizing/Mixing System Recommended Spare Parts and Accessories DFV Replacement Parts Components 35539 – DFV – ALL 36081 – DFV2.5–5# DFV––7–5# DFV–14–5# 36082 – DFV2.5–8# DFV––7–8# DFV–14–8# 36118 – DFV2.5–5# DFV––7–5# 36106 – DFV2.5–8# DFV––7–8# DFV–14–8# 31304 36113 - DFV – 110VAC 36112 - DFV – 220VAC 40287 50330 - DFV – 110VAC 53124 - DFV – 220VAC 51476 - DFV – 110VAC 53017 - DFV – 220VAC 37009 - DFV2.5 DFV––7 37009 - DFV–14 53096 - DFV – ALL 33950 – DFV2.5–5# 33951 – DFV––7–5# 33952 – DFV–14–5# 33953 – DFV2.5–8# 33953 – DFV––7–8# 32070 – DFV–14–8# 20122 31051 40490 36080 31016 30638 30641 52681 52642 Description SWITCH, PRESSURE, VENTURI CONTROL (MIXED GAS), 0-20 PSI Qty. 1 SWITCH, PRESSURE HIGH TANK (MIXED GAS), 4–12 PSI 1 SWITCH, PRESSURE HIGH TANK (MIXED GAS), 8–25 PSI 1 SWITCH, PRESSURE, LOW VAPOR, 20-50 PSI 1 SWITCH, PRESSURE, LOW VAPOR, 40–120 PSI 1 RELIEF VALVE (SURGE TANK) VALVE, SOLENOID, ¾” (SAFETY AND VENTURI CONTROL) VALVE, SOLENOID, ¾” (SAFETY AND VENTURI CONTROL) REPAIR KIT, SOLENOID VALVE LAMP, 110V LAMP, 220V CONTROL RELAY, 110V CONTROL RELAY, 220V 1 2 2 2 1 1 1 1 ELECTRONIC IGNITOR 117V / 220V 1 ELECTRONIC IGNITOR 117V / 220V FUSE, 1-1/2 AMP SLO-BLO 2 1 REGULATOR, 627 1 GASKET, VENTURI HOUSING O-RING (DIFFUSER) VENTURI CHECK VALVE REBUILD KIT SILENCER AIR INLET SCREEN GAUGE, PRESSURE, 0-100 PSI GAUGE, PRESSURE, 0-300 PSI MANUAL, DFV MANUAL, DIRECT FIRED 1 1 1 1 1 1 1 1 1 AlgasSDI Operations and Maintenance Manual – DFV – P/N: 52681 Appendix A AlgasSDI Operations and Maintenance Manual – DFV – P/N: 52681 Installation & Maintenance Instructions SERIES 8003G 8202G OPEN-FRAME, GENERAL PURPOSE, WATERTIGHT/EXPLOSIONPROOF SOLENOIDS INSTALLATION Ċ SERVICE NOTICE Ċ ASCO solenoid valves with design change letter G" or H" in the catalog number (ex. 8210G 1) have an epoxy encapsulated ASCO Red Hat II solenoid. This solenoid replaces some of the solenoids with metal enclosures and open-frame constructions. Follow these installation and maintenance instructions if your valve or operator uses this solenoid. See separate instructions for basic valve. Check nameplate for correct catalog number, service, and wattage. Check front of solenoid for voltage and frequency. WARNING: Electrical hazard from the accessibility of live parts. To prevent the possibility of death,Ăserious injury or property damage, install the open - frame solenoid in an enclosure. FOR BLACK ENCLOSURE TYPES 7 AND 9 ONLY DESCRIPTION Catalog numbers 8003G and 8202G are epoxy encapsulated pull-type solenoids. The green solenoid with lead wires and 1/2Ăconduit connection is designed to meet Enclosure Type 1-General Purpose, Type 2-Dripproof, Types 3 and 3S-Raintight, and Types 4 and 4X-Watertight. The black solenoid on catalog numbers prefixed EF" or EV" is designed to meet Enclosure Types 3 and 3S-Raintight, Types 4 and 4X-Watertight, Types 6 and 6P-Submersible, Type 7 (A, B, C & D) Explosionproof Class I, Division 1 Groups A, B, C, & D and Type 9 (E, F, & G)-Dust-Ignitionproof Class II, Division 1 Groups E, F & G. The Class II, Groups F & G Dust Locations designation is not applicable for solenoids or solenoid valves used for steam service or when a class H" solenoid is used. See Temperature Limitations section for solenoid identification and nameplate/retainer for service. When installed just as a solenoid and not attached to an ASCO valve, the core has a 0.250-28 UNF-2B tapped hole, 0.38 or 0.63 minimum full thread. NOTE: Catalog number prefix EV" denotes stainless steel construction. Catalog numbers 8202G1, 8202G3, 8202G5 and 8202G7 are epoxy encapsulated push-type, reverse-acting solenoids having the same enclosure types as previously stated for Catalog numbers 8003G1 and 8003G2. Series 8003G and 8202G solenoids are available in: Open-Frame Construction: The green solenoid may be supplied with 1/4 spade, screw or DIN terminals. (Refer to Figure 4) Panel Mounted Construction: These solenoids are specifically designed to be panel mounted by the customer through a panel having a .062 to .093 maximum wall thickness. Refer to Figure 1 and section on Installation of Panel Mounted Solenoid. Optional Features For Type 1 - General Purpose Construction Only Junction Box: This junction box construction meets Enclosure Types 2,3,3S,4, and 4X. Only solenoids with 1/4 spade or screw terminals may have a junction box. The junction box provides a 1/2 conduit connection, grounding and spade or screw terminal connections within the junction box (See Figure 5). DIN Plug Connector Kit No.K236034:Ă Use this kit only for solenoids with DIN terminals. The DIN plug connector kit provides a two pole with grounding contact DIN Type 43650 construction (See Figure 6). OPERATION Series 8003G - When the solenoid is energized, the core is drawn into the solenoid base sub-assembly. IMPORTANT: When the solenoid is de-energized, the initial return force for the core, whether developed by spring, pressure, or weight, must exert a minimum force to overcome residual magnetism created by the solenoid. Minimum return force for AC construction is 11 ounces, and 5 ounces for DC construction. Series 8202G - When the solenoid is energized, the disc holder assembly seats against the orifice. When the solenoid is de-energized , the disc holder assembly returns. IMPORTANT: Initial return force for the disc or disc holder assembly, whether developed by spring, pressure, or weight, must exert a minimum force to overcome residual magnetism created by the solenoid. Minimum return force is 1 pound, 5 ounces. MM Form No.V6584R8 All Rights Reserved. 50 Hanover Road, Florham Park, New Jersey 07932 CAUTION: To prevent fire or explosion, do not install solenoid and/or valve where ignition temperature of hazardous atmosphere is less than 165 C. On valves used for steam service or when a class H" solenoid is used, do not install in hazardous atmosphere where ignition temperature is less than 180C. See nameplate/retainer for service. NOTE: These solenoids have an internal non-resetable thermal fuse to limit solenoid temperature in the event that extraordinary conditions occur which could cause excessive temperatures. These conditions include high input voltage, a jammed core, excessive ambient temperature or a shorted solenoid, etc. This unique feature is a standard feature only in solenoids with black explosionproof/dust-ignitionproof enclosures (Types 7 & 9). CAUTION: To protect the solenoid valve or operator, install a strainer or filter, suitable for the service involved in the inlet side as close to the valve or operator as possible. Clean periodically depending on service conditions. See ASCO Series 8600, 8601, and 8602 for strainers. Temperature Limitations For maximum valve ambient temperatures, refer to chart. The temperature limitations listed, only indicate maximum application temperatures for field wiring rated at 90C. Check catalog number prefix and watt rating on nameplate to determine maximum ambient temperature. See valve installation and maintenance instructions for maximum fluid temperature. NOTE: For steam service, refer to Wiring section, Junction Box for temperature rating of supply wires. Temperature Limitations For Series 8003G or 8202G Solenoids for use on Valves Rated at 10.1, 11.6, 17.1, or 22.6 Watts Watt Rating Catalog Number Coil Prefix Class of Insulation Maximum Ambient Temp. 10.1 & 17.1 None, FB, KF, KP SC, SD, SF, & SP, F 125F (51.7C) 10.1 & 17.1 HB, HT, KB, KH, SS, ST, SU, H 140F (60C) 11.6 & 22.6 None, FB,KF, KP, SC, SD, SF, & SP. F 104F (40C) 11.6 & 22.6 HP, HT, KB, KH, SS, ST, SU, & SV H 104F (40C) Minimum ambient temperature -40 F (-40 C). Positioning This solenoid is designed to perform properly when mounted in any position. However, for optimum life and performance, the solenoid should be mounted vertically and upright to reduce the possibility of foreign matter accumulating in the solenoid base sub-assembly area. Wiring Wiring must comply with local codes and the National Electrical Code. All solenoids supplied with lead wires are provided with a grounding wire which is green or green with yellow stripes and a 1/2 conduit connection. To Printed in U.S.A. www.ascovalve.com Page 1 of 4 facilitate wiring, the solenoid may be rotated 360. For the watertight and explosionproof solenoid, electrical fittings must be approved for use in the approved hazardous locations. CAUTION: Cryogenic Applications - Solenoid lead wire insulation should not be subjected to cryogenic temperatures. Adequate lead wire protection and routing must be provided. Additional Wiring Instructions For Optional Features: Open-Frame solenoid with 1/4 spade terminals. For solenoids supplied with screw terminal connections use #12-18 AWG stranded copper wire rated at 90C or greater. Torque terminal block screws to 10 ± 2 in-lbs [1,0 ± 1,2 Nm]. A tapped hole is provided in the solenoid for grounding, use a #10-32 machine screw. Torque grounding screw to 15 - 20 in-lbs [1,7 - 2,3 Nm]. On solenoids with screw terminals, the socket head screw holding the terminal block to the solenoid is the grounding screw. Torque the screw to 15 - 20 in-lbs [1,7 - 2,3 Nm] with a 5/32 hex key wrench. Junction Box The junction box is used with spade or screw terminal solenoids only and is provided with a grounding screw and a 1/2 conduit connection. Connect #12-18 AWG standard copper wire only to the screw terminals. Within the junction box use field wire that is rated 90C or greater for connections. For steam service use 105C rated wire up to 50 psi or use 125C rated wire above 50 psi. After electrical hookup, replace cover gasket, cover, and screws. Tighten screws evenly in a crisscross manner. DIN Plug Connector Kit No.K236034 1. The open-frame solenoid is provided with DIN terminals to accommodate the plug connector kit. 2. Remove center screw from plug connector. Using a small screwdriver, pry terminal block from connector cover. 3. Use #12-18 AWG stranded copper wire rated at 90C or greater for connections. Strip wire leads back approximately 1/4 for installation in socket terminals. The use of wire-end sleeves is also recommended for these socket terminals. Maximum length of wire-end sleeves to be approximately 1/4.ĂTinning of the ends of the lead wires is not recommended. 4. Thread wire through gland nut, gland gasket, washer and connector cover. NOTE: Connector housing may be rotated in 90 increments from position shown for alternate positioning of cable entry. 5. Check DIN connector terminal block for electrical markings. Then make electrical hookup to terminal block according to markings on it. Snap terminal block into connector cover and install center screw. 6. Position connector gasket on solenoid and install plug connector. Torque center screw to 5 ± 1 in-lbs [0,6 ± 1,1 Nm]. NOTE: Alternating current (AC) and direct current (DC) solenoids are built differently. To convert from one to the other, it may be necessary to change the complete solenoid including the core and solenoid base sub-assembly, not just the solenoid. Consult ASCO. Installation of Solenoid Solenoids may be assembled as a complete unit. Tightening is accomplished by means of a hex flange at the base of the solenoid. Installation of Panel Mounted Solenoid (See Figure 1) 1. Disassemble solenoid following instruction under Solenoid Replacement then proceed. 2. Install solenoid base sub-assembly through customer panel. 3. Position spring washer on opposite side of panel over solenoid base sub-assembly. 4. Replace solenoid, nameplate/retainer and red cap. 5. Make electrical hookup, see Wiring section. Solenoid Temperature Standard solenoids are designed for continuous duty service. When the solenoid is energized for a long period, the solenoid becomes hot and can be touched by hand only for an instant. This is a safe operating temperature. MAINTENANCE WARNING: To prevent the possibility of death, serious injury or property damage, turn off electrical power, depressurize solenoid operator and/or valve, and vent fluid to a safe area before servicing. Cleaning All solenoid operators and valves should be cleaned periodically. The time between cleaning will vary depending on medium and service conditions. In general, if the voltage to the solenoid is correct, sluggish valve operation, excessive noise or leakage will indicate that cleaning is required. Clean strainer or filter when cleaning the valve. Preventive Maintenance Keep the medium flowing through the solenoid operator or valve as free from dirt and foreign material as possible. While in service, the solenoid operator or valve should be operated at least once a month to insure proper opening and closing. Depending on the medium and service conditions, periodic inspection of internal valve parts for damage or excessive wear is recommended. Thoroughly clean all parts. Replace any worn or damaged parts. Causes of Improper Operation Faulty Control Circuit: Check the electrical system by energizing the solenoid. A metallic click signifies that the solenoid is operating. Absence of the click indicates loss of power supply. Check for loose or blown fuses, open-circuited or grounded solenoid, broken lead wires or splice connections. Burned-Out Solenoid: Check for open-circuited solenoid. Replace if necessary. Check supply voltage; it must be the same as specified on nameplate/retainer and marked on the solenoid. Check ambient temperature and check that the core is not jammed. Low Voltage: Check voltage across the solenoid leads. Voltage must be at least 85% of rated voltage. Solenoid Replacement 1. Disconnect conduit, coil leads, and grounding wire. NOTE: Any optional parts attached to the old solenoid must be reinstalled on the new solenoid. For 3-way construction, piping or tubing must be removed from pipe adapter. 2. Disassemble solenoids with optional features as follows: Spade or Screw Terminals Remove terminal connections, grounding screw, grounding wire, and terminal block (screw terminal type only). NOTE: For screw terminals, the socket head screw holding the terminal block serves as a grounding screw. Junction Box Remove conduit and socket head screw (use 5/32 hex key wrench) from center of junction box. Disconnect junction box from solenoid. DIN Plug Connector Remove center screw from DIN plug connector. Disconnect DIN plug connector from adapter. Remove socket head screw (use 5/32 hex key wrench), DIN terminal adapter, and gasket from solenoid. 3. Snap off red cap from top of solenoid base sub-assembly. For 3-way construction with pipe adapter (Figure 3), remove pipe adapter, nameplate and solenoid. Omit steps 4 and 5. 4. Push down on solenoid. Then using a suitable screwdriver, insert blade between solenoid and nameplate/retainer. Pry up slightly and push to remove. NOTE: Series 8202G solenoids have a spacer between the nameplate/ retainer and solenoid. 5. Remove solenoid from solenoid base sub-assembly. 6. Reassemble in reverse order of disassembly. Use exploded views for identification and placement of parts. 7. Torque pipe adapter to 90 inch-pounds maximum [10,2 Nm maximum]. Then make up piping or tubing to pipe adapter on solenoid. Disassembly and Reassembly of Solenoids 1. Remove solenoid, see Solenoid Replacement. 2. Remove spring washer from solenoid base sub-assembly. For 3-way construction, remove plugnut gasket. 3. Unscrew solenoid base sub-assembly from valve body. 4. Remove internal solenoid parts for cleaning or replacement. Use exploded views for identification and placement of parts. 5. If the solenoid is part of a valve, refer to basic valve installation and maintenance instructions for further disassembly. 6. Torque solenoid base sub-assembly and adapter to 175±25 in-lbs [19,8±2,8 Nm]. ORDERING INFORMATION FOR ASCO SOLENOIDS When Ordering Solenoids for ASCO Solenoid Operators or Valves, order the number stamped on the solenoid. Also specify voltage and frequency. Page 2 of 4 Form No.V6584R8 50 Hanover Road, Florham Park, New Jersey 07932 www.ascovalve.com Torque Chart Part Name solenoid base sub-assembly & adapter pipe adapter Torque Value Inch-Pounds 175 ± 25 90 maximum Remove red cap and push solenoid down. Then pry here to lift nameplate/retainer and push to remove. Remove red cap and push solenoid down. Then pry here to lift nameplate/retainer and push to remove. red cap nameplate/ retainer grounding wire green or green with yellow stripes solenoid with 1/2 NPT finger washer .062 to .093 maximum thickness of panel for mounting core (AC) Torque Value Newton-Meters 19,8 ± 2,8 10,2 maximum 0.69 diameter mounting hole core (DC) Side View finger washer solenoid base sub-assembly Tapped hole in core 0.250-28 UNF-2B 0.63 minimum full thread (AC) 0.38 minimum full thread (DC) collar to face valve body 0.9375-26 UNS -2A thread Alternate Construction Panel Mount Figure 1. Series 8003G solenoids red cap Remove red cap and push solenoid down. Then pry here to lift nameplate/retainer and push to remove. nameplate/ retainer pipe adapter spacer plugnut gasket grounding wire green or green with yellow stripes solenoid with 1/2 NPT spring washer solenoid base sub-assembly bonnet washer core(small end up) solenoid base gasket plugnut assembly cutaway view to show positioning of retainer in gasket recess Without Adapter retainer gasket retainer adapter gasket stem disc disc holder assembly disc spring disc holder spring Figure 2. Series 8202G solenoids adapter Air Only Construction Vent to Atmosphere With Adapter Figure 3. 3-Way Construction Form No.V6584R8 50 Hanover Road, Florham Park, New Jersey 07932 www.ascovalve.com Page 3 of 4 Torque Chart Part Name terminal block screws socket head screw center screw Torque Value in Inch-Pounds 10 ± 2 15 - 20 5±1 Open-Frame Solenoid with Screw Terminals. Socket head screw is used for grounding. Open-Frame Solenoid with 1/4 Spade Terminals See torque chart above Open-Frame Solenoid with DIN Terminals screw terminal adapter Indicates parts supplied in Termination Module Kit No. K256104 terminal block screw tapped hole for #10-32 grounding screw (not included) Torque Value in Newton-Meters 1,1 ± 0,2 1,7 - 2,3 0,6 ± 0,1 gasket DIN terminal adapter socket head grounding screw (5/32 hex key wrench) socket head screw (5/32 hex key wrench) Figure 4. Open-frame solenoids Junction Box Solenoid with 1/4 Spade Terminals or Screw Terminals screw terminal block (see note) cover screw See torque chart above cover cover gasket grounding screw and cup washer junction box gasket Note: Junction box with screw terminals shown. With screw terminal block removed, remaining parts comprise the junction box for spade terminal construction. junction box with 1/2 conduit connection and grounding terminal socket head screw (5/32 hex key wrench) Figure 5. Junction box (optional feature) Open-Frame Solenoid with DIN Terminal Plug Conector DIN terminal adapter See torque chart above connector gland nut gasket gland gasket socket head screw (5/32 hex key wrench) Notes: 1. Connector cover may be rotated in 90 increments from position shown for alternate position of cable entry. 2. Refer to markings on DIN connector for proper electrical connections. Page 4 of 4 Indicates that these parts are included in DIN plug connector Kit No. K236034 gasket DIN connector terminal block (see note 2) washer center screw connector cover (see note 1) Figure 6. DIN plug connector kit No. K236034 (optional feature) 50 Hanover Road, Florham Park, New Jersey 07932 www.ascovalve.com Form No.V6584R8 Instruction Manual Form 5252 627 Series Incorporates Errata dated January 2001 07/89 627 Series Pressure Reducing Regulators Description Introduction Scope of Manual This manual provides instructions for the installation, adjustment, maintenance, and parts ordering for the 627 Series regulators. These regulators usually are shipped separate for line installation, although sometimes they are shipped installed on other equipment. Refer to the instruction manual for the other equipment for installation and operating instructions. The 627 Series self-operated pressure reducing regulators (figure 1) are for high and low pressure systems. These regulators can be used with natural gas, air, or a variety of other gases. Performance characteristics vary according to construction (see the AVAILABLE CONFIGURATIONS specification in table 1). Specifications Table 1 gives some general specifications for the 627 Series regulators. The nameplates (figure 2) gives detailed information for a particular regulator as it comes from the factory. NUMBER 1 10B3679-D W4793 NUMBER 2 Figure 2. Nameplates D101328X012 Figure 1. Typical 627 Series Self-Operated Pressure Reducing Regulator Regulators www.FISHERregulators.com 627 Series Table 1. Specifications Available Constructions Type 627: Self-operated pressure reducing regulator equipped with a pitot tube for greater regulated capacities (figure 7) Type 627R: Type 627 with internal relief and with an open throat (figure 8) Type 627M: Type 627 with a stem seal between the body outlet pressure and diaphragm case. Pressure is measured under the diaphragm through the 1/4-inch NPT downstream control line connection (figure 9) Type 627MR: Type 627M with internal relief (figure 10) Type 627H: Type 627 with a diaphragm limiter to deliver a higher outlet pressure (figure 11) Type 627HM: Type 627H with a stem seal between the body outlet pressure and diaphragm case. Pressure is measured under the diaphragm through two 1/4-inch NPT downstream control line connections (figure 12) Body Sizes 3/4, 1, or 2-inch End Connection Styles 3/4, 1, or 2-inch body sizes: NPT 1 or 2-inch body sizes: ANSI Class 300 or 600 RF flanged Maximum Inlet Pressure(1) (Body Rating) 2000 psig (138 bar) for NPT steel, 1480 psig (102 bar) for RF flanged steel, or 1000 psig (69 bar) for ductile iron Maximum Valve Disk Inlet Pressure Rating(1) 2000 psig (138 bar) for nylon disk or 1000 psig (69 bar) for nitrile disk Maximum Operating Inlet Pressure, Pressure Differential, and Outlet Pressure Ranges(1) See table 2 for pressures by port and spring range Maximum Spring and Diaphragm Casing Pressure(1) Maximum Body Outlet Pressure(1) (Type 627M, 627MR, and 627HM Only) 2000 psig (138 bar) for screwed steel, 1480 psig (102 bar) for RF flanged steel, or 1000 psig (69 bar) for ductile iron. (Type 627 and 627R are limited by maximum diaphragm casing pressure) Port Diameters See table 2 Internal Relief Performance Type 627R: See table 4 Type 627MR: Limited by field-installed control line piping Temperature Capabilities(1) -20 to 180°F (-29 to 82°C) Pressure Registration Type 627, 627H or 627R: Internal Type 627M, 627HM or 627MR: External through 1/4-inch NPT control line connection in the diaphragm casing De-Icer System See figure 3 and Type 627M Regulator De-Icer System Application section Relief Indicator For 627R and 627MR (see figures 8 and 9) Spring Case Vent Connection 3/4-inch NPT female with removable screened vent assembly Control Line Connection (Type 627M, 627HM or 627MR Only) 1/4-inch NPT female Approximate Weight Ductile Iron or Steel Casings: 10 pounds (4,5 kg) Aluminum Casings: 6.3 pounds (2.8 kg) See table 3 1. The pressure/temperature limits in this instruction manual or any applicable standard limitation should not be exceeded. 2 627 Series Table 2. Maximum Inlet Pressures, Differential Pressures, and Outlet Pressure Ranges TYPE NUMBER OUTLET PRESSURE RANGE, SPRING PART NUMBER, AND COLOR 5(2) to 20 psig (0,34 to 1,4 bar) 10B3076X012 Yellow 15 to 40 psig (1,0 to 2,8 bar) 627 and 627M(3) 10B3077X012 Green 35 to 80 psig (2,4 to 5,5 bar) 10B3078X012 Blue 70 to 150 psig (4,8 to 10,3 bar) 10B3079X012 Red 5(2) to 20 psig (0,34 to 1,4 bar) 10B3076X012 Yellow 15 to 40 psig (1,0 to 2,8 bar) 627R and 627MR 10B3077X012 Green 35 to 80 psig (2,4 to 5,5 bar) 10B3078X012 Blue 70 to 150 psig (4,8 to 10,3 bar) 10B3079X012 Red 140 to 250 psig (9,7 to 17,2 bar) 627H and 627MH(3) 10B3078X012 Blue 240 to 500 psig (16,5 to 34,5 bar) 10B3079X012 Red ORIFICE SIZE, INCHES (mm) MAXIMUM INLET PRESSURE, PSIG (bar) MAXIMUM DIFFERENTIAL PRESSURE, PSID (bar) 3/32 1/8 3/16 1/4 3/8 1/2 (2,4) (3,2) (4,8) (6,4) (9,5) (12,7) 2000 1000 750 500 300 250 (138)(1) (69)(1) (51,7) (34,5) (20,7) (17,2) 2000 1000 750 500 300 250 (138)(1) (69)(1) (51,7) (34,5) (20,7) (17,2) 3/32 1/8 3/16 1/4 3/8 1/2 (2,4) (3,2) (4,8) (6,4) (9,5) (12,7) 2000 1500 1000 750 500 300 (138)(1) (103)(1) (69)(1) (51,7) (34,5) (20,7) 2000 1500 1000 750 500 300 (138)(1) (103)(1) (69)(1) (51,7) (34,5) (20,7) 3/32 1/8 3/16 1/4 3/8 1/2 (2,4) (3,2) (4,8) (6,4) (9,5) (12,7) 2000 2000 1750 1500 1000 750 (138)(1) (138)(1) (121)(1) (103)(1) (69)(1) (51,7) 2000 2000 1750 1500 1000 750 (138)(1) (138)(1) (121)(1) (103)(1) (69)(1) (51,7) 3/32 1/8 3/16 1/4 3/8 1/2 (2,4) (3,2) (4,8) (6,4) (9,5) (12,7) 2000 2000 2000 1750 1250 750 (138)(1) (138)(1) (138)(1) (121)(1) (86,2)(1) (51,7) 2000 2000 2000 1750 1250 750 (138)(1) (138)(1) (138)(1) (121)(1) (86,2)(1) (51,7) 3/32 1/8 3/16 1/4 3/8 1/2 (2,4) (3,2) (4,8) (6,4) (9,5) (12,7) 2000 1000 750 500 300 200 (138)(1) (69)(1) (51,7) (34,5) (20,7) (13,8) 2000 1000 750 500 300 200 (138)(1) (69)(1) (51,7) (34,5) (20,7) (13,8) 3/32 1/8 3/16 1/4 3/8 1/2 (2,4) (3,2) (4,8) (6,4) (9,5) (12,7) 2000 1500 1000 750 300 200 (138)(1) (103)(1) (69)(1) (51,7) (20,7) (13,8) 2000 1500 1000 750 300 200 (138)(1) (103)(1) (69)(1) (51,7) (20,7) (13,8) 3/32 1/8 3/16 1/4 3/8 1/2 (2,4) (3,2) (4,8) (6,4) (9,5) (12,7) 2000 1750 1000 750 300 200 (138)(1) (121)(1) (69)(1) (51,7) (20,7) (13,8) 2000 1750 1000 750 300 200 (138)(1) (121)(1) (69)(1) (51,7) (20,7) (13,8) 3/32 1/8 3/16 1/4 3/8 1/2 (2,4) (3,2) (4,8) (6,4) (9,5) (12,7) 2000 1000 500 300 200 200 (138)(1) (69)(1) (34,5) (20,7) (13,8) (13,8) 2000 1000 500 300 200 200 (138)(1) (69)(1) (34,5) (20,7) (13,8) (13,8) 3/32 1/8 3/16 1/4 3/8 1/2 (2,4) (3,2) (4,8) (6,4) (9,5) (12,7) 2000 2000 1750 1500 1000 750 (138)(1) (138)(1) (121)(1) (103)(1) (69)(1) (51,7) 2000 2000 1750 1000 500 250 (138)(1) (138)(1) (121)(1) (69)(1) (34,5) (17,2) 3/32 1/8 3/16 1/4 3/8 1/2 (2,4) (3,2) (4,8) (6,4) (9,5) (12,7) 2000 2000 1750 1500 1000 750 (138)(1) (138)(1) (121)(1) (103)(1) (69)(1) (51,7) 2000 2000 1750 1000 500 250 (138)(1) (138)(1) (121)(1) (69)(1) (34,5) (17,2) 1. For inlet pressure in excess of 1000 psig (69 bar), refer to the maximum body and disk pressure ratings in the specification table. 2. For pressure settings under 10 psig (0,69 bar), inlet pressure should be limited to approximately 100 psig (6,9 bar) so the setpoint adjustment can be obtained. 3. The unbalance forces change from the wide-open monitor mode to an active regulator mode such that the Type 627M or 627MH should have a 3/8-inch (9,5 mm) or larger orifice when used as a wide-open monitor. 3 627 Series Table 3. Maximum Spring and Diaphragm Casing Pressure(1) SPRING AND DIAPHRAGM CASING STYLE TYPE 627, PSIG (bar) TYPE 627R, PSIG (bar) Maximum pressure to spring and diaphragm casings to prevent leak to atmosphere other than relief action (internal par ts damage may occur) Die cast aluminum 250 (17,2) 250 (17,2) Die cast aluminum 250 (17,2) 250 (17,2) 250 (17,2) Steel 250 (17,2) 250 (17,2) 250 (17,2) Maximum pressure to spring and diaphragm casings to prevent burst of casings during abnormal operation (leak to atmosphere and internal par ts damage may occur) Die cast aluminum 375 (25,9) 375 (25,9) MAXIMUM PRESSURE DESCRIPTION Maximum diaphragm casing over pressure (above setpoint) to prevent damage to internal par ts TYPE 627M, PSIG (bar) TYPE 627MR, PSIG (bar) TYPE 627H AND 627HM, PSIG (bar) Not Available Not Available Not Available Not Available Not Available 250 (17,2) 800 (55,2) Not Available Not Available Not Available Ductile iron 465 (32) 465 (32) 465 (32) 465 (32) Not Available Steel 1500 (103) 1500 (103) 1500 (103) 1500 (103) 1500 (103) All styles 60 (4,1) 120 (8,3) 60 (4,1) 120 (8,3) 120 (8,3) 1. If the spring case is pressurized, a metal adjusting screw cap is required. Contact your Fisher Sales Representative. Personal injury, property damage, equipment damage, or leakage due to escaping gas or bursting of pressure-containing parts may result if this regulator is overpressured or is installed where service conditions could exceed the limits given in tables 1, 2, 3, and 4, or where conditions exceed any ratings of the adjacent piping or piping connections. To avoid such injury or damage, provide pressure-relieving or pressure-limiting devices (as required by the appropriate code, regulation, or standard) to prevent service conditions from exceeding those limits. The Type 627R or 627MR regulator with internal relief will provide downstream overpressure protection within the limits given in tables 1, 2, 3 and 4. If these limits are exceeded additional downstream overpressure protection must be provided by the user. Additionally, physical damage to the regulator could cause personal injury or property damage due to escaping gas. To avoid such injury or damage, install the regulator in a safe location. Like most regulators, 627 Series regulators have outlet pressure ratings that are lower than their inlet pressure ratings. A pressure relieving or pressure limiting device must be provided by the user for the Type 627, 627H, 627M, and 627HM regulators if the inlet pressure can exceed the outlet pressure rating, since these regulators do not have internal relief. Type 627R regulators provide internal relief which limits the total outlet pressure buildup over setpoint. Use table 4 to determine the total outlet pressure. This internal relief may be adequate for the application, if not, provide additional pressure relief or a pressure limiting device downstream. Note If the regulator is shipped mounted on another unit, install that unit according to the appropriate instruction manual. Perform steps 1 through 6 for all types of regulators: 1. Only personnel qualified through training and experience should install, operate, or maintain this regulator. 2. For a regulator that is shipped separately, make sure that there is no damage to, or foreign material in, the regulator. Installation 3. Ensure that all tubing and piping have been blown free of foreign debris. Regulator operation within ratings does not preclude the possibility of damage from debris in the lines or from external sources. A regulator should be inspected for damage periodically and after any overpressure condition. Key numbers referenced in this section are shown in figures 7 through 12. Ensure that the operating temperature capabilities listed in table 1 are not exceeded. 4. The regulator may be installed in any position as long as the flow through the body is in the direction indicated by the arrow cast on the body. 4 5. If continuous operation is required during inspection or maintenance, install a three-valve bypass around the regulator. 627 Series Figure 3. Schematic of De-Icer System connected to a straight section of outlet piping 10 diameters downstream of the regulator. A regulator may vent some gas to the atmosphere. In hazardous or flammable gas service, vented gasmay accumulate and cause personal injury, death, or property damage due to fire or explosion. Vent a regulator in hazardousgas service toa remote, safe location away from air intakes or any hazardous area. The vent line or stack opening must be protected against condensation or clogging. 6. Position the body (key 1) and/or diaphragmspring case (key 29) so it will not collectmoisture or debris into the screened vent. If the regulator requires repositioning, refer to the body area maintenance procedures and/or the diaphragm case area maintenance procedures in the Maintenance section to reposition the screened vent for the application. 9. A hand valve should be installed in the control line. This hand valve can be used to throttle down and dampen outlet pulsations in control pressure which may cause unstability or cycling of the regulator. Remote Vent Line Installation All 627 series regulators have a vent assembly installed in the 3/4-inch NPT spring case vent opening. The vent assembly can be removed to install a remote vent line if necessary. Remote vent lines must have the largest practical diameter. The vent line should be as short as possible with a minimum number of bends or elbows. Protect the remote vent opening against entrance of rain, snow, or any other foreign material that may plug the vent or vent line and prevent proper operation of the regulator. Periodically check the vent opening to be sure it is not plugged with foreign debris. Perform steps 7 through 9 for Types 627M, 627HM, and 627MR regulators only: 7. A Type 627M, 627HM, or 627MR regulator requires a downstream control line. Install the control line before putting the regulator into operation. 8. Ensure that the downstream control line piping is at least 3/8-inch or larger outside diameter tubing and Type 627M or 627HM Regulator DeIcer System Application For the Type 627M or 627HM regulator de-icer system, refer to the application shown in figure 3. With a large pressure drop across the working regulator, ice can 5 627 Series Table 4. Type 627R Internal Relief Performance(1) OUTLET MAXIMUM OUTLET PRESSURE ALLOWABLE PRESSURE RANGE, SPRING DOWNSTREAM SETTING, PART NUMBER, SYSTEM PRESSURE, PSIG (bar) AND COLOR PSIG (bar) Orifice Size, Inches (mm) 3/8 (9,5) 1/2 (12,7) 10 (0,69) 60 (4,1) 100 (6,9) 125 (8,6) 175 (12,1) 200 (13,8) 250 (17,2) 1250 2000 2000 2000 2000 2000 (86,2) (138) (138) (138) (138) (138) 740 (51,1) 1500 (103) 1900 (131) 2000 (138) 2000 (138) 2000 (138) 320 (22,1) 620 (42,7) 830 (57,2) 1100 (75,8) 1300 (89,6) 1600 (110) 190 390 480 670 770 960 (13,1) (26,9) (33,1) (46,2) (53,1) (66,2) 95 (6,56) 180 (12,4) 220 (15,2) 320 (22,1) 360 (24,8) 450 (31,0) 75 (5,18) 130 (8,97) 160 (11,0) 220 (15,2) 260 (17,9) 320 (22,1) 15 (1,0) 60 (4,1) 100 (6,9) 125 (8,6) 175 (12,1) 200 (13,8) 250 (17,2) 1000 2000 2000 2000 2000 2000 (69,0) (138) (138) (138) (138) (138) 620 (42,7) 1400 (96,5) 1900 (131) 2000 (138) 2000 (138) 2000 (138) 260 (17,9) 610 (42,1) 810 (55,8) 1100 (75,8) 1300 (89,6) 1600 (110) 170 370 480 670 770 960 (11,7) (25,5) (33,1) (46,2) (53,1) (66,2) 90 170 220 320 360 450 70 130 160 220 260 320 20 (1,4) 60 (4,1) 100 (6,9) 125 (8,6) 175 (12,1) 200 (13,8) 250 (17,2) 850 (58,6) 2000 (138) 2000 (138) 2000 (138) 2000 (138) 2000 (138) 490 (33,8) 1300 (89,6) 1800 (124) 2000 (138) 2000 (138) 2000 (138) 210 (14,5) 600 (41,4) 800 (55,2) 1100 (75,8) 1300 (89,6) 1600 (110) 130 (9,0) 360 (24,8) 480 (33,1) 670 (46,2) 770 (53,1) 960 (66,2) 80 (5,52) 170 (11,7) 220 (15,2) 320 (22,1) 360 (24,8) 450 (31,0) 65 (4,49) 120 (8,28) 160 (11,0) 220 (15,2) 260 (17,9) 320 (22,1) 15 (1,0) 60 (4,1) 100 (6,9) 125 (8,6) 175 (12,1) 200 (13,8) 250 (17,2) 1000 2000 2000 2000 2000 2000 (69,0) (138) (138) (138) (138) (138) 380 (26,2) 1300 (89,6) 1800 (124) 2000 (138) 2000 (138) 2000 (138) 210 (14,5) 590 (40,7) 800 (55,2) 1100 (75,8) 1300 (89,6) 1600 (66,2) 130 350 470 640 780 960 80 170 220 320 370 450 ( 5,5) (11,7) (15,2) (22,1) (25,5) (31,0) 65 (4,49) 120 (8,28) 160 (11,0) 220 (15,2) 260 (17,9) 320 (22,1) 20 (1,4) 60 (4,1) 100 (6,9) 125 (8,6) 175 (12,1) 200 (13,8) 250 (17,2) 630 (43,4) 2000 (138) 2000 (138) 2000 (138) 2000 (138) 2000 (138) 200 (13,8) 1200 (82,7) 1700 (117) 2000 (138) 2000 (138) 2000 (138) 150 (10,3) 550 (37,9) 760 (52,4) 1100 (75,8) 1300 (89,6) 1600 (66,2) 100 (6,9) 330 (22,8) 450 (31,1) 630 (43,4) 770 (53,1) 960 (66,2) 70 ( 4,83) 160 (11,0) 210 (14,5) 320 (22,1) 360 (24,8) 460 (31,7) 65 (4,49) 120 (8,28) 160 (11,0) 220 (15,2) 260 (17,9) 320 (22,1) 30 (2,1) 100 (6,9) 125 (8,6) 175 (12,1) 200 (13,8) 250 (17,2) 2000 2000 2000 2000 2000 (138) (138) (138) (138) (138) 950 (65,5) 1500 (103) 2000 (138) 2000 (138) 2000 (138) 450 (31,1) 670 (46,2) 1000 (69,0) 1200 (82,7) 1600 (110) 260 400 610 760 970 (17,9) (27,6) (42,1) (52,4) (66,9) 140 190 300 360 460 (9,66) (13,1) (20,7) (24,8) (31,7) 110 150 220 260 320 (7,59) (10,3) (15,2) (17,9) (22,1) 40 (2,8) 100 (6,9) 125 (8,6) 175 (12,1) 200 (13,8) 250 (17,2) 1500 2000 2000 2000 2000 (103) (138) (138) (138) (138) 700 (48,3) 1300 (89,6) 1800 (124) 2000 (138) 2000 (138) 330 (22,8) 560 (38,6) 1000 (69,0) 1200 (82,7) 1600 (110) 200 340 550 730 970 (13,8) (23,4) (37,9) (50,3) (66,9) 120 180 290 350 460 (8,28) (12,4) (20,0) (24,1) (31,7) 108 140 220 250 320 (7,45) (9,66) (15,2) (17,2) (22,1) 5(3) to 20 psig (0,34 to 1,4 bar) 10B3076X012 Yellow 15 to 40 psig (1,0 to 2,8 bar) MAXIMUM INLET PRESSURE TO KEEP MAXIMUM ALLOWABLE DOWNSTREAM SYSTEM PRESSURE FROM BEING EXCEEDED, PSIG (bar)(2) 10B3077X012 Green 3/32 (2,4) form with in this regulator. The formation of ice decreases the size of the port opening, so the regulator is unable to supply enough flow to satisfy the downstream demand. When the downstream pressure falls below the outlet pressure setting of the Type 627M or 627HM regulator, the disk assembly of the Type 627Mor 627HMregulator moves off its seat ring, permitting alcohol to flow into the main gas line. The alcohol carried to the main regulator by the flow stream prevents additional ice from forming on the seat ring. When normal flow resumes, and as pressure in the downstream system is restored, the Type 627M or 627HM regulator shuts off. 6 1/8 (3,2) 3/16 (4,8) 1/4 (6,4) (8,97) (24,1) (32,4) (44,1) (53,8) (66,2) (6,2) (11,7) (15,2) (22,1) (24,8) (31,0) (4,8) (8,97) (11,0) (15,2) (17,9) (22,1) Startup and Adjustment Startup To avoid personal injury or property damage due to explosion or damage to regulator or downstream components during startup, release downstream pressure to prevent an overpressure condition on the diaphragm of the regulator. 627 Series Table 4. Type 627R Internal Relief Performance(1) (continued) OUTLET PRESSURE RANGE, SPRING PART NUMBER, AND COLOR MAXIMUM OUTLET ALLOWABLE PRESSURE DOWNSTREAM SETTING, SYSTEM PRESSURE, PSIG (bar) PSIG (bar) MAXIMUM INLET PRESSURE TO KEEP MAXIMUM ALLOWABLE DOWNSTREAM SYSTEM PRESSURE FROM BEING EXCEEDED, PSIG (bar)(2) Orifice Size, Inches (mm) 3/32 (2,4) 1/8 (3,2) 3/16 (4,8) 1/4 (6,4) 3/8 (9,5) 1/2 (12,7) 40 (2,8) 125 (8,6) 150 (10,3) 175 (12,1) 200 (13,8) 250 (17,2) 2000 2000 2000 2000 2000 (138) (138) (138) (138) (138) 1100 1600 2000 2000 2000 (75,8) (110) (138) (138) (138) 500 (34,5) 750 (51,7) 980 (67,6) 1200 (82,7) 1600 (110) 300 440 580 720 940 (20,7) (30,3) (40,0) (49,6) (64,8) 170 230 290 340 450 (11,7) (15,9) (20,0) (23,4) (31,0) 140 180 220 250 320 (9,66) (12,4) (15,2) (17,2) (22,1) 50 (3,4) 125 (8,6) 150 (10,3) 175 (12,1) 200 (13,8) 250 (17,2) 1400 2000 2000 2000 2000 (96,5) (138) (138) (138) (138) 820 (56,5) 1400 (96,5) 1900 (131) 2000 (138) 2000 (138) 400 (27,6) 650 (44,8) 700 (48,3) 1100 (75,8) 1500 (103) 230 370 530 670 920 (15,9) (25,5) (36,5) (46,2) (63,4) 150 210 270 330 430 (10,3) (14,5) (18,6) (22,8) (29,6) 140 170 210 240 320 (9,66) (11,7) (14,5) (16,5) (22,1) 60 (4,1) 125 (8,6) 150 (10,3) 175 (12,1) 200 (13,8) 250 (17,2) 900 (62,1) 1700 (117) 2000 (138) 2000 (138) 2000 (138) 450 (31,1) 1100 (75,8) 1700 (117) 2000 (138) 2000 (138) 270 (18,6) 540 (37,2) 780 (53,8) 1000 (69,0) 1400 (96,5) 190 300 470 610 880 (13,1) (20,7) (32,4) (42,1) (60,7) 140 190 250 310 420 (9,66) (13,1) (17,2) (21,4) (29,0) 130 160 200 230 310 (8,97) (11,0) (13,8) (15,9) (21,4) 70 (4,8) 150 175 200 250 (10,3) (12,1) (13,8) (17,2) 1200 2000 2000 2000 (82,7) (138) (138) (138) 850 (58,6) 1400 (96,5) 2000 (138) 2000 (138) 430 (29,6) 670 (46,2) 920 (63,4) 1300 (89,6) 250 400 550 830 (17,2) (27,6) (37,9) (57,2) 170 230 280 400 (11,7) (15,9) (19,3) (27,6) 160 190 230 310 (11,0) (13,1) (15,9) (21,4) 80 (5,5) 150 175 200 250 (10,3) (12,1) (13,8) (17,2) 800 (55,2) 1500 (103) 2000 (138) 2000 (138) 500 (34,5) 1200 (82,7) 1700 (117) 2000 (138) 300 (20,7) 550 (37,9) 800 (55,2) 1200 (82,7) 200 330 480 770 (13,8) (22,8) (33,1) (53,1) 160 210 270 390 (11,0) (14,5) (18,6) (26,9) 150 190 220 300 (10,3) (13,1) (15,2) (20,7) 70 (4,8) 175 (12,1) 200 (13,8) 250 (17,2) 1900 (131) 2000 (138) 2000 (138) 600 (41,4) 1200 (82,7) 2000 (138) 400 (27,6) 630 (43,4) 1100 (75,8) 260 (17,9) 380 (26,2) 680 (46,9) 200 (13,8) 250 (17,2) 360 (24,8) 175 (12,1) 210 (14,5) 290 (20,0) 70 to 150 psig (4,8 to 10,3 bar) 80 (5,5) 175 (12,1) 200 (13,8) 250 (17,2) 1400 (96,5) 2000 (138) 2000 (138) 250 (17,2) 960 (66,2) 2000 (138) 240 (16,5) 520 (35,9) 1000 (69,0) 200 (13,8) 330 (22,8) 620 (42,7) 190 (13,1) 240 (16,5) 350 (24,1) 175 (12,1) 210 (14,5) 280 (19,3) 10B3079X012 Red 100 (6,9) 200 (13,8) 250 (17,2) 1500 (103) 2000 (138) 250 (17,2) 1600 (110) 240 (16,5) 770 (53,1) 230 (15,9) 520 (35,9) 210 (14,5) 320 (22,1) 210 (14,5) 270 (18,6) 125 (8,6) 250 (17,2) 2000 (138) 1000 (69,0) 500 (34,5) 390 (26,9) 290 (20,0) 260 (17,9) 150 (10,3) 250 (17,2) 1200 (82,7) 260 (17,9) 260 (17,9) 260 (17,9) 260 (17,9) 260 (17,9) 35 to 80 psig (2,4 to 5,5 bar) 10B3078X012 Blue 1. The internal relief performance values are obtained by removing the disk assembly. 2. For inlet pressures in excess of 1000 psig (69 bar), refer to the maximum body and disk pressure ratings in the specifications table. 3. For pressure settings under 10 psig (0,69 bar), inlet pressure should be limited to approximately 100 psig (6,9 bar) so the setpoint adjustment can be obtained. - Shaded areas indicate maximum inlet pressures allowed during system malfunction only. Table 6 gives the maximum inlet pressure for normal regulator operation. In order to avoid an overpressure condition and possible equipment damage, pressure gauges should always be used to monitor pressures during startup. 1. Slowly open the upstream shutoff valve. 2. Slowly open the downstream shutoff valve. 3. Check all connections for leaks. 4. Make final control spring adjustments according to the adjustment procedures. Adjustment The range of allowable pressure settings is marked on the nameplate (figure 2). If a pressure setting beyond this range is necessary, substitute the appropriate regulator control spring. Change the nameplate to indicate the new pressure range. Before increasing the setting, refer to tables 2, 3, or 4. Review the pressure limits for the control spring range being used and be certain that the new pressure setting will not result in an overpressure condition. 7 627 Series Table 5. Maximum Torque Values KEY NUMBER(1) 2 3 DESCRIPTION MAXIMUM TORQUE, FOOT-POUNDS (N•m) Seat ring 25 (34) Cap screw (w/ aluminum diaphragm casing) 16 (22) Cap screw (w/ ductile iron or steel diaphragm casing) 25 (34) 7 (9) 17 (23) 18 Lever cap screw 22 Diaphragm connector nut 26 Guide retainer (for Type 627R and 627MR only) 3 (4) Spring case cap screw (w/ aluminum or ductile iron diaphragm casing) 7 (9) 35 (47) 7 (9) 14 (19) 37 46 Spring case cap screw (w/ steel diaphragm casing) Diaphragm cap screw (w/Type 627 or 627M) Diaphragm cap screw (w/Type 627H or 627MH) 1. Refer to figures 7 through 10 for key number locations. Note Always use a pressure gauge to monitor pressure when making adjustments. Refer to figures 7 through 12 for key number locations. 1. Remove the adjusting screw cap (key 36). 2. Loosen the locknut (key 34). 3. Increase the outlet pressure setting by turning the adjusting screw (key 35) clockwise. Decrease the outlet pressure setting by turning the adjusting screw counterclockwise. 4. When the desired pressure is obtained, hold the adjusting screw (key 35) in place and tighten the locknut (key 34). Shutdown To avoid personal injury or property damage due to explosion or damage to regulator or downstream components during shutdown, release downstream pressure to prevent an overpressure condition on the diaphragm of the regulator. 1. Close the nearest upstream shutoff valve. 2. Close the nearest downstream shutoff valve. 8 3. Open the vent valve between the regulator and the downstream shutoff valve nearest to it. 4. For a Type 627, 627H, or 627R regulator, the regulator will open to release pressure between the upstream shutoff valve and the regulator. 5. A Type 627M, 627HM, or 627MR regulator requires venting the control line and downstream pressure from the regulator before maintenance. The pressure between these shutoff valves is released through the open regulator because the disk assembly remains open in response to the decrease in control line pressure. Maintenance Unless otherwise specified, the following maintenance procedures apply to all types of regulators. For a summary of maximum torque values required for all types of regulators, refer to table 5. Due to normal wear, damage from external sources, or debris in the air or gas line, regulator parts such as the disk assembly, seat ring, and diaphragm must be inspected periodically and replaced as necessary to ensure correct performance. The frequency of inspection and replacement depends upon the severity of conditions and the requirements of state and federal laws. Normal wear of the seat ring and disk assembly is accelerated with high pressure drops and with large amounts of impurities in the flow stream. Instructions are given below for replacing the disk assembly, seat ring, diaphragm, and O-rings. These procedures may also be used for disassembly required for inspection and replacement of other parts. 627 Series Problem Indication for Type 627R and 627MR Regulators Isolate the regulator from all pressure to avoid personal injury and equipment damage due to explosion or sudden release of process pressure. Cautiously release pressure from the regulator before attempting disassembly. The vent assembly is equipped with a relief indicator (key 49, figure 4). The cap for the relief indicator snaps over the vent assembly opening. If the relief valve opens wide, exhaust gas pops the cap off the screen vent assembly opening indicating a problem with the regulator. If the cap pops off, refer to the shutdown and to the body area maintenance procedures to inspect the disk assembly and seat ring. If the disk assembly and seat ring are not damaged, refer to the diaphragm and spring case area maintenance procedures in this section. The disk assembly and seat ring can be inspected, removed, and replaced without removing the regulator body from the line connections. Refer to the body area maintenance procedures. Body Area Maintenance Procedures These procedures are for gaining access to the disk assembly, seat ring, diaphragm casing O-ring and stem assembly. All pressure must be released from the diaphragm casing before the performing these steps. While using the following procedures, refer to figures 7 through 12 for key number locations. Replacing the Disk Assembly or Seat Ring 1. To inspect and replace the disk assembly (key 9) or seat ring (key 2), remove the cap screws (key 3, figure 5), and separate the diaphragm casing (key 5) from the body (key 1). 2. Inspect and, if necessary, remove the seat ring (key 2). If removed, coat the threads of the replacement seat ring with lubricant (key 38) and torque to 25 foot-pounds (34 N•m). 3. Inspect the disk assembly and, if necessary, remove the hair pin clip (key 13) that holds the disk assembly (key 9) in place. If replacing the disk assembly is the only maintenance required, skip to step 16. RELIEF INDICATOR CAP (KEY 49) W4665* Figure 4. Relief Indicator Replacing the Stem Assembly If it is necessary to perform maintenance on the stem assembly, continue with steps 4 through 8 and 15 through 19 for Type 627, 627H, and 627R regulators, or steps 9 through 19 for Type 627M, 627HM, and 627MR regulators. Perform steps 4 through 8 for Type 627, 627H, and 627R Regulators only: 4. ForType 627, 627H, and627R regulators (figure 5), use steps 5 through 8 to remove and replace the stem assembly. 5. Remove the boost body (key 6), stabilizer (key 7), and stem guide (key 8) from the diaphragm casing (key 5). Unhook and remove the stem (key 10) from the diaphragm casing (key 5). 6. Remove and inspect the diaphragm casing O-ring (key 4, figure 7, 8, or 11) and replace it if necessary. 7. Apply lubricant (key 42) to a replacement diaphragm casing O-ring (key 4, figure 7, 8, or 11) and install it onto the boost body (key 6). Skip to step 14. 8. For the Type 627 or 627H regulators, be sure to insert the pitot tube (tab) into the outlet side of the body (see figure 7 or 11). Skip to step 14. Perform steps 9 through 19 for Type 627M, 627HM, and 627MR Regulators only: 9. For Type 627M, 627HM, and 627MR regulators (figure 5), use steps 10 through 14 to remove and replace the stem assembly. 10. To remove the blocked throat (key 43), insert a screw driver blade into the groove provided in the throat and pry it out of the diaphragm casing (key 5). Inspect and replace parts as necessary. 9 627 Series LEVER (KEY 15) STEM BACKUP RINGS (KEY 12) HAIR PIN CLIP (KEY 13) DIAPHRAGM CASING O-RING (KEY 4) STEM (KEY 10) BODY (KEY 1) DISK ASSEMBLY (KEY 9) STEM GUIDE (KEY 8) CAP SCREW (KEY 3) DIAPHRAGM CASING (KEY 5) STEM O-RING (KEY 11) W4792* STABILIZER (KEY 7) BOOST BODY (KEY 6) PITOT TUBE AND TAB FOR TYPE 627 ONLY SEAT RING (KEY 2) Type 627 and 627R BLOCKED THROAT BACKUP RINGS (KEY 45) BLOCKED THROAT (KEY 43) BLOKED THROAT O-RINGS (KEY 44) W4791* Type 627M amd 627MR Figure 5. Stem Assemblies 11. Inspect and, if necessary, replace the blocked throat O-rings (key 44, figure 5) and backup rings (key 45, figure 5). 12. Apply lubricant (key 42) to replacement blocked throat O-rings (key 44) and backup rings (key 45). 19. It may be necessary to reposition the diaphragm spring case to prevent rain, ice, and foreign debris from entering the spring case. Refer to the diaphragm and spring case area maintenance procedures, steps 1, 2, and 21 through 25. 13. Apply lubricant (key 42) to the replacement stem O-ring (key 11) and stem backup rings (key 12) and install them on the stem (key 10). Diaphragm and Spring Case Area Maintenance Procedures 14. For assembly, insert the stem (key 10) into the diaphragm casing (key 5) and hook it on the lever (key 15). These procedures are for gaining access to the control spring, diaphragm assembly, and lever assembly. All spring pressure must be released from the diaphragm casing before these steps can be performed. 15. Insert parts into the diaphragm casing (key 5) that were removed in steps 5 and 6 or step 10 (see figure 5). 16. Install the the disk assembly (key 9), line up the hole in the disk assembly and stem (key 10) and insert the hair pin clip (key 13). 17. Position the diaphragm casing plus attached parts in relation to the body (key 1) so that they are correct for the application. 18. Secure the diaphragm casing to the body with the cap screws (key 3, figure 5). For an aluminum diaphragm casing (key 5), torque the cap screws (key 3) to 16 foot-pounds (22 N•m). For ductile iron or steel diaphragm casings, torque the cap screws (key 3) to 25 foot-pounds (34 N•m). 10 While using the following procedures, refer to figures 7 through 12 for key number locations. 1. Remove the adjusting screw cap (key 36), loosen the lock nut, and turn the adjusting screw (key 35) counterclockwise until all compression is removed from the control spring (key 32). 2. Remove the spring case cap screws (key 37), the nameplates, and lift off the spring case (key 29). If changing the control spring (key 32) or repositioning the spring case (key 29) is the only maintenance required, install the replacement control spring or rotate the spring case so it is correct for the application. Skip to step 21. For diaphragm area maintenance, continue with step 3. 627 Series DIAPHRAGM (KEY 23) DIAPHRAGM HEAD (KEY 24) RELIEF VALVE O-RING (KEY 28) DIAPHRAGM CONNECTOR NUT (KEY 22) RELIEF VALVE SPRING (KEY 27) PUSTHER POST (KEY 19) GUIDE RETAINER O-RING (KEY 48) W4668* RELIEF SEAL RETAINER (KEY 47) LOWER SPRING SEAT (KEY 31) DIAPHRAGM CONNECTOR ASSEMBLY (KEY 21) UPPER SPRING SEAT (KEY 33) GUIDE RETAINER (KEY 26) Type 627, 627R, 627M, or 627MR DIAPHRAGM (KEY 23) PUSTHER POST (KEY 19) DIAPHRAGM LIMITER O-RING (KEY 51) DIAPHRAGM LIMITER (KEY 50) DIAPHRAGM HEAD (KEY 24) W5433-1* PUSTHER POST O-RING (KEY 52) DIAPHRAGM HEAD CAP SCREW (KEY 46) Type 627H amd 627HM Figure 6. Diaphragm Assemblies 3. Remove the diaphragm limiter and O-ring (keys 50 and 51, on the Type 627H or 627HM only). Remove the diaphragm assembly by tilting it so that the pusher post (key 19) slips off the lever (key 15). 4. If it is necessary to replace the lever assembly, remove the lever cap screws (key 18). 5. Install the replacement lever (key 15) into the lever retainer (key 16) by inserting the lever pin (key 17). Secure the lever assembly into the diaphragm casing with the cap screws (key 18) and torque the cap screws to 7 foot-pounds (9 N•m). If it is necessary to perform maintenance on the diaphragm assembly, continue with steps 6 through 11 and step 20 for Type 627, 627H, 627M, and 627HM regulators, or steps 12 through 19 for Type 627R and 627MR regulators. Perform steps 6 through 11 for Type 627, 627H, 627M, and 627HM Regulators only: 6. For Type 627, 627H, 627M, and 627HM regulators (figures 5 & 6), use steps 7 through 11 to disassemble and reassemble the diaphragm assembly. 7. Remove the diaphragm head cap screw (key 46), lower spring seat (key 31,Type 627 or 627Monly), and diaphragm head (key 24). On the Type 627H or 627HM, remove the diaphragm cap screw O-rings (key 52). Separate the diaphragm (key 23) from the pusher post (key 19). 8. Install the diaphragm (key 23), in reverse order in step 7, on the pusher post (key 19), insert and finger tighten the diaphragm head cap screw (key 46). 9. Hook the pusher post on the lever (key 15), then turn the diaphragm (key 23) to match the holes in the diaphragm with the holes in the spring casing. 10. Unhook the pusher post from the lever and torque the diaphragm head cap screw (key 46) to 7 footpounds (9 N•m) for the Type 627 or 627M. On the Type 627H or 627HM torque the diaphragm head cap screw to 14 foot-pounds (18 N•m). 11. Hook the pusher post on the lever (key 15) and check the hole alignment. If necessary, loosen the cap screw (key 46) and reposition the diaphragm (key 23) on the pusher post (key 19). Retorque the screw (see step 10). Skip to step 20. 11 627 Series Perform steps 12 through 19 for Type 627R and 627MR Regulators only: 12. For Type 627R and 627MR regulators (figure 6), use steps 13 through 19 to disassemble and reassemble the diaphragm assembly: 24. Using a crisscross pattern, finish tightening the spring case cap screws (key 37) to 7 foot-pounds (9 N•m) of torque. 25. If necessary, refer to the installation and/or the startup and adjustment procedures. 13. Remove the guide retainer (key 26) and separate the diaphragm parts. Refer to figure 6 for the sequence of parts. 26. Install the adjusting screw cap (key 34) after regulator adjustment. 14. To remove the diaphragm (key 23), remove the diaphragm connector nut (key 22) and lift off the diaphragm head (key 24) and diaphragm (key 23) from the connector assembly (key 21). Do not attempt to disassemble the connector assembly (key 21). Parts Ordering When corresponding with your Fisher sales office or sales representative about this regulator, always reference the type number which is found on the nameplate (key 39, figures 7 through 12). 15. Position the replacement diaphragm (key 23) on the connector assembly (key 21), install the diaphragm head (key 24) and connector nut (key 22), then torque to 17 foot-pounds (32 N•m). When ordering replacement parts, reference the key number of each needed part as found in the following parts list. 16. If necessary, replace the guide retainer O-ring (key 48) and, set the guide retainer (key 26) aside, ready for assembly. Parts List Key 17. On the pusher post (key 19) install the relief seal O-ring (key 28) and lubricate (key 42). Also, install the relief seal retainer (key 47), diaphragm connector assembly (key 21, with attached parts) relief spring (key 27), upper relief spring seat (key 33), and guide retainer (key 26). Torque the guide retainer (key 26) to 3 foot-pounds (4 N•m). 18. Hook the pusher post (with attached parts) on the lever (key 15) to check the alignment of the holes in the diaphragm with the holes in the spring casing. If the holes do not line up, unhook the pusher post from the lever, hold the pusher post, and rotate the diaphragm to the correct position. Type 627 Parts Kit with aluminum/nitrile trim (includes keys 4, 9, 11, 12, and 23) Type 627R Parts Kit with aluminum/nitrile trim (includes keys 4, 9, 11, 12, 23, 28, and 48) 23. Screw in the adjustment screw to put slack into the diaphragm (key 23). 1 2* Body Ductile iron 1000 psig (69 bar) max inlet pressure 3/4-inch NPT size 1-inch NPT size 2-inch NPT size Steel 2000 psig (138 bar) max inlet pressure 3/4-inch NPT size 1-inch NPT size 2-inch NPT size Steel, ANSI Class 600 RF flanged 1480 psig (102 bar) max inlet pressure 1-inch size 2-inch size Seat ring Aluminum 3/32-inch (2.4 mm) port diameter 1/8-inch (3.2 mm) port diameter 3/16-inch (4.8 mm) port diameter 1/4-inch (6.4 mm) port diameter 3/8-inch (9.5 mm) port diameter 1/2-inch (12.7 mm) port diameter 303 Stainless steel 3/32-inch (2.4 mm) port diameter 1/8-inch (3.2 mm) port diameter 3/16-inch (4.8 mm) port diameter 1/4-inch (6.4 mm) port diameter 3/8-inch (9.5 mm) port diameter 1/2-inch (12.7 mm) port diameter *Recommended spare part. 12 R627X000A12 R627RX00A12 Type 627R Parts Kit with stainless steel/nitrile trim (includes keys 4, 9, 11, 12, 23, 28, and 48) R627RX00S12 20. Insert the diaphragm assembly into the diaphragm casing (key 5) and hook the pusher post on the lever (key 15). 22. Install the spring case (key 29) so that the screened vent assembly (key 30) is in the correct position for the application. Place the nameplates (key 39) over the screw holes, insert the spring case cap screws (key 37), and finger tighten. Part Number Type 627 Parts Kit with stainless steel/nitrile trim (includes keys 4, 9, 11, 12, and 23) R627X000S12 19. Install the lower spring seat (key 31) over the relief spring so it rests flat on the connector nut (key 22). 21. Install the control spring (key 32) and upper spring seat (key 33), and apply lubricant (key 38) to the upper spring seat (key 33). Description 30B3046X012 30B3048X012 30B3096X012 30B3050X012 30B3051X012 30B7452X012 40B6754X012 40B6756X012 0R044109022 1A936709012 00991209012 0B042009012 0B042209012 1A928809012 0R044135032 1A936735032 00991235032 0B042035032 0B042235032 1A928835032 627 Series Key Description Part Number Key Description 2* Seat ring (continued) 316 Stainless steel, NACE(1) construction only 3/32-inch (2.4 mm) port diameter 0R0441X0012 1/8-inch (3.2 mm) port diameter 1A9367X0022 3/16-inch (4.8 mm) port diameter 009912X0012 1/4-inch (6.4 mm) port diameter 0B0420X0012 3/8-inch (9.5 mm) port diameter 0B0422X0012 1/2-inch (12.7 mm) port diameter 1A9288X0012 Cap Screw (not shown), (2 req’d) Type 627 and 627R w/aluminum diaphragm case, pl steel 18A1087X012 All Types w/ductile iron diaphragm case, pl steel 1C403824052 or steel diaphragm case, pl steel 1C403024052 Diaphragm Case O-Ring (Type 627, 627H, or 627R only), nitrile 17A2325X022 Diaphragm Case For Type 627 or 627R Aluminum w/o 1/8-inch gauge tap 40B3084X012 Aluminum with 1/8-inch gauge tap for Type 627 only 11B5380X012 Ductile iron w/o 1/8-inch gauge tap 30B3053X012 Ductile iron with 1/8-inch gauge tap for Type 627 only 31B0641X012 Steel 30B3104X012 For Type 627M or 627MR Ductile iron 39A5987X012 Steel 30B8734X012 For Type 627H, steel 30B3104X012 For Type 627HM, steel 30B8734X012 Boost Body (not for Type 627M, 627HM, (2) or 627MR), Delrin For Type 627 or 627H 30B3056X012 For Type 627R 30B3057X012 Stabilizer (for Type 627, 627H, and 627R only), nitrile 10B3060X012 Stem Guide (for Type 627, 627H, and 627R only), powdered metal 20B3061X012 Disk Assembly (for all port diameters) Aluminum holder and nitrile disk 1C4248X0212 303 Stainless steel holder and nitrile disk 1C4248X0202 Aluminum holder and nylon disk 1C4248X00A2 303 Stainless steel holder and nylon disk 1C4248X0062 NACE construction only Aluminum holder and nitrile disk 1C4248X0212 316 Stainless steel holder and nitrile disk 1C4248X0252 Aluminum holder and nylon disk 1C4248X00A2 316 Stainless steel holder and nylon disk 1C4248X0262 Stem 303 stainless steel 10B3059X012 316 stainless steel (NACE) 10B3059X022 Stem O-Ring, nitrile 1D687506992 Stem Backup Ring, TFE (2 required) 1K786806992 Hair Pin Clip, stainless steel 10B3058X012 Drive Pin, plated steel 1A953228982 Lever, plated steel 20B3063X012 Lever Retainer, plated steel 30B3097X012 Lever Pin Stainless steel 10B3083X012 316 stainless steel (NACE) 10B3083X022 Lever Cap Screw (2 required) Plated steel 10B7454X012 316 stainless steel (NACE) 10B7454X022 Pusher Post, aluminum For Type 627 or 627M 10B3098 X012 For Type 627R or 627MR 10B3098 X022 For Type 627H or 627HM, 416 stainless steel 10B3098 X032 Diaphragm Connector (for Type 627R or 627MR only), stainless steel 10B6758X012 Diaphragm Connector Nut (for Type 627R or 627MR only), stainless steel 10B7449X012 Diaphragm, nitrile For Type 627 or 627M w/aluminum or ductile iron diaphragm case 10B3069X012 23* Diaphragm, nitrile (continued) For Type 627 or 627M w/steel diaphragm case For Type 627R or 627MR w/aluminum or ductile iron diaphragm case For Type 627R or 627MR w/steel diaphragm case For Type 627H or 627HM w/steel diaphragm case (diaphragm is neoprene with nylon fabric) Diaphragm Head, plated steel For Type 627 or 627M, plated steel For Type 627R or 627MR, plated steel For Type 627H or 627HM, 416 stainless steel Relief Spring Seat (for Type 627R or 627MR only), steel Guide Retainer (for Type 627R or 627MR only), stainless steel Relief Spring (for Type 627R or 627MR only), plated steel Relief Seal O-Ring (for Type 627R or 627MR only), nitrile Spring Case For Type 627 or 627R Aluminum Ductile iron Steel For Type 627M or 627MR Ductile iron Steel For Type 627H or 627HM Steel Screened Vent Assembly, plastic Lower Spring Seat, plated steel For Type 627 or 627M For Type 627R or 627MR Control Spring, pl steel 5 to 20 psig (0.34 to 1.4 bar), yellow 15 to 40 psig (1.0 to 2.8 bar), green 35 to 80 psig (2.4 to 5.5 bar), blue 70 to 150 psig (4.8 to 10.3 bar), red 140 to 250 psig range (9.6 to 17.2 bar), blue, used in a Type 627H or 627HM 240 to 500 psig range (16.5 to 34.5 bar), red, used in a Type 627H or 627HM Upper Spring Seat, plated steel Locknut, plated steel Adjusting Screw, pl steel For Type 627 or 627M For Type 627H or 627HM For Type 627R or 627MR Adjusting Screw Cap, plastic Spring Case Cap Screw, pl steel (8 required) For aluminum or ductile iron diaphragm case For steel diaphragm case For Type 627H/HM, steel diaphragm case Nameplate Blocked Throat (for Type 627M, 627HM or 627MR only), stainless steel Blocked Throat O-Ring (for Type 627M, 627HM, or 627MR only), nitrile (2 required) Blocked Throat Backup Ring (for Type 627M, 627HM, or 627MR only), TFE (2 required) Diaphragm Head Cap Screw, steel For Type 627 or 627M For Type 627H or 627HM Relief Seal Retainer (for Type 627R or 627MR only), stainless steel Guide Retainer O-Ring (for Type 627R or 627MR only), nitrile Relief Indicator (for Type 627R or 627MR only), rubber (not shown) Diaphragm Limiter Diaphragm Limiter O-Ring Pusher Post O-Ring (2 required) 3 4* 5 6 7 8 9* 10 11* 12 13 14 15 16 17 18 19 21 22 23* 24 25 26 27 28* 29 30 31 32 33 34 35 36 37 39 43 44 45 46 47 48* 49 50 51* 52* Part Number 10B8735X012 10B3068X012 10B8736X012 12B0178X012 1D666428982 10B3071X012 12B0175X012 10B7446X012 10B7450X012 10B6757X012 1J108506992 40B3086X012 30B3055X012 30B3102X012 30B3055X012 30B3102X012 30B3102X012 10B3093X012 1D666625072 20B3073X012 10B3076X012 10B3077X012 10B3078X012 10B3079X012 10B3078X012 10B3079X012 1D667125072 1D667728982 10B3081X012 10B3081X012 10B3080X012 20B3082X012 1A391724052 10B8737X012 1A346424052 ----------10B3085X012 1E264306992 10B3106X012 1K920724052 1C379124052 10B7445X012 1D682506992 30B3100X012 22B0176X012 1K877606992 1C853806992 13 627 Series 30B3092-D Figure 7. Type 627 Regulator Components 14 627 Series 30B3089-D Figure 8. Type 627R Regulator Components 15 627 Series 30B6433-C 1/4-INCH NPT CONNECTION Figure 9. Type 627M Regulator Components 16 627 Series 1/4-INCH NPT CONNECTION 30B6434-D Figure 10. Type 627MR Regulator Components 17 627 Series 31B5374-B Figure 11. Type 627H Regulator Components 18 627 Series 31B9872-B Figure 12. Type 627HM Regulator Components 19 627 Series January 2001 Errata Sheet for 627 Series Form 5252, July 1989 This errata sheet includes information covering the Type 627LB extended body regulator. This new body style is available on all 627 Series configurations and will be an addition to key 1 in the Parts List. The pressure ratings on the Type 627LB bodies will be identical to the existing specifications stated in the current 627 Series Instruction Manual. Each bullet on this errata sheet refers to a section of the 627 Series Instruction Manual (form 5252) where this infornation needs to be added. • Add the following to the Available Constructions section of Table 1. Specifications on page 2. • Add the following figure to the end of page 18. Type 627LB: A 627 Series construction with an extended NPT screwed body. Note: The pressure ratings and capacities for a Type 627LB depend on the 627 Series construction. See the above listed constructions for ratings and specifications. • Add the following to the Parts List on page 12. Key Description 1 Body Type 627LB - Ductile iron 1000 psig (69 bar) max inlet pressure 3/4-inch NPT screwed body 1-inch NPT screwed body 2-inch NPT screwed body Type 627LB - Steel 2000 psig (138 bar) max inlet pressure 3/4-inch NPT screwed body 1-inch NPT screwed body 2-inch NPT screwed body Part Number 39B2450X012 39B2451X012 39B0414X012 E0650 39B0411X012 39B0412X012 39B0415X012 Figure 13. Type 627LB Regulator Body ©Fisher Controls International, Inc., 1986, 1989; All Rights Reserved Fisher and Fisher Regulators are marks owned by Fisher Controls International, Inc. The Emerson logo is a trade mark and service mark of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. For information, contact Fisher Controls: Marshalltown, Iowa 50158 USA 28320 Gallardon, France Sao Paulo 05424 Brazil Singapore 128461 Printed in U.S.A. www.FISHERregulators.com Regulators KUNKLE PRESSURE RELIEF VALVES Installation and Operating Instructions Pre-Installation Handling This pressure relief valve is designed to protect equipment from overpressure. The valve should be handled with care, not subjected to heavy shock loads, and protected to prevent dirt from getting inside. It should be installed correctly. Failure to do so could result in property damage or serious injury to personnel. Installation 1. Mount the valve in a vertical position so that the valve body is self draining. If a body drain port is provided, make sure it is open when required by the ASME code. Do not plug any bonnet vent openings. The inlet piping should be as short as possible, with no elbows, and equal to or greater than the size of the pressure relief valve inlet connection. This will help to limit the inlet pressure drop to 3% or less when the valve is relieving. 2. When discharge piping is connected to valve outlet, make sure it is self draining if a body drain port is not used. The valve should not be connected to any discharge pipe that contains pressure before the valve opens or to any pipe where the pressure build-up is greater than 10% of the set pressure when the valve is open and relieving. Discharge piping, other than a short tailpipe, must be supported. For steam service, a drip pan elbow or flexible connection between the valve and the pipe should be used to prevent excessive pipe stress, due to thermal expansion, from being imposed on the valve body. 3. For threaded valves, apply a small amount of pipe thread sealing compound to external threads only. Do not put any sealing compound on the first thread or on any internal threads. To do so may cause the sealing compound to enter the valve and cause seat leakage. Use the wrench flats provided to tighten the valve to the connecting pipe. Do not use the valve body or bonnet and do not over-tighten. To do so may cause valve leakage. 4. For flanged valves, use new gaskets and tighten the mounting studs evenly. Operation 1. Maintain a system operating pressure at least 5 psig or 10% below the set pressure of the valve, whichever is greater. Operating too close to the valve set pressure will cause seat leakage and will shorten the time between valve maintenance. 2. Do not use the safety valve as a control valve to regulate system operating pressure. Excessive operation will cause the seat to leak and will require more frequent valve maintenance. 3. ASME Section I and VIII valves equipped with lift levers are designed to be operated only when the system pressure is 75% of set pressure or greater. ASME Section IV valves may be operated at any set pressure. When hand operating the valve, hold it open long enough to purge any foreign matter from the seat area. If a cable or wire is attached to the lift lever for remote actuation, make sure the direction of pull is the same as it would be if the lever were pulled directly by hand. Maintenance Maintenance should be performed on a regular basis. An initial inspection interval of 12 months is recommended. Depending on the service conditions and the condition of the e valve, the inspection interval may be decreased or increased. Use only Kunkle parts for repair. Depending o the local jurisdictional requirements where the valve is installed, repairs may have to be made by a repair facility holding a VR stamp Kunkle An Anderson, Greenwood Company Phone: 828-669-55151281 Old US 70, Black Mountain, NC 28711 Fax: 828-669-0586 Safety Warning — LP-Gas Pressure Relief Valves Purpose In its continuing quest for safety, Engineered Controls International, Inc. is publishing safety warning bulletins explaining the hazards associated with the use, misuse and aging of ECII®/ RegO® Products. LPGas dealer managers and service personnel must realize that the failure to exercise the utmost care and attention in the installation, inspection and maintenance of these products can result in personal injury and property damage. The National Fire Protection Association Pamphlet #58 “Storage and Handling of Liquefied Petroleum Gases” states: “In the interests of safety, all persons employed in handling LP-Gases shall be trained in proper handling and operating procedures.” ECII® Warning Bulletins are useful in training new employees and reminding older employees of potential hazards. This Warning Bulletin should be provided to all purchasers of ECII® / RegO® Products and all personnel using or servicing these products. Additional copies are available from Engineered Controls International, Inc. and your Authorized ECII®/ RegO® Products Distributor. What You Must Do: • Read This Entire Warning • Install Properly • Inspect Regularly • Replace In 10 Years or Less Scope This bulletin applies to pressure relief valves installed on stationary, portable and cargo containers and piping systems utilized with these containers. This bulletin is not intended to be an exhaustive treatment of this subject and does not cover all safety practices that should be followed in the installation and maintenance of LP-Gas systems. Each LP-Gas employee should be provided with a copy of NPGA Safety Pamphlet 306 “LP-Gas Regulator and Valve Inspection and Maintenance” as well as the NPGA “LP-Gas Training Guidebooks” relating to this subject. Warnings should be as brief as possible. If there is a simple warning, it is: Inspect pressure relief valves regularly. Replace unsafe or suspect valves immediately. Use common sense. Install Properly Consult NFPA Pamphlet #58 and/or any applicable regulations governing the application and use of pressure relief valves. Make sure you are thoroughly trained before you attempt any valve installation, inspection or maintenance. adapters on ECII®/ RegO® relief valves. Adapters not designed specifically for piping away ECII®/ RegO® relief valves, such as those with 90° turns or reduced internal diameters, will decrease flow dramatically. These should never be used as they can cause the relief valve to chatter and eventually destroy itself. Proper installation is essential to the safe operation of pressure relief valves. When installing ECII®/ RegO® pressure relief valves, consult warning # 8545-500 which accompanies each valve. Check for damage and proper operation after valve installation. Check that the valve is clean and free of foreign material. The addition of deflectors, pipeaway adapters and piping will restrict the flow. To properly protect any container, the total system flow must be sufficient to relieve pressure at the pressure setting of the relief valve in accordance with all applicable codes. Pipeaways and deflectors may be required by local codes, laws and regulations depending on the installation. Use only ECII®/ RegO® ® D4 PRODUCTS Inspect Regularly A pressure relief valve discharges when some extraordinary circumstance causes an over pressure condition in the container. If a pressure relief valve is known to have discharged, the relief valve, as well as the entire system, should be immediately and thoroughly inspected to determine the reason for the discharge. In the case of discharge due to fire, the valve should be removed from service and replaced. Relief valves should be inspected each time the container is filled but no less than once a year. If there is any doubt about the condition of the valve, it must be replaced. Eye protection must be worn when performing inspection on relief valves under pressure. Never look directly into a relief valve under pressure or place any part of your body where the relief valve discharge could impact it. In some cases a flashlight and a small mirror are suggested to assist when making visual inspections. To Properly Inspect A Pressure Relief Valve, Check For: 1. A rain cap. Check protective cap located in valve or at end of pipeaway for a secure fit. Protective caps help protect the relief valve against possible malfunction caused by rain, sleet, snow, ice, sand, dirt , pebbles, insects, other debris and contamination. REPLACE DAMAGED OR MISSING CAPS AT ONCE AND KEEP A CAP IN PLACE AT ALL TIMES. 4. Physical damage. Ice accumulations and improper installation could cause mechanical damage. IF THERE ARE ANY INDICATIONS OF DAMAGE, REPLACE THE VALVE. 5. Tampering or readjustment. Pressure relief valves are factory set to discharge at specified pressures. IF THERE ARE ANY INDICATIONS OF TAMPERING OR READJUSTMENT, REPLACE THE VALVE. 6. Seat leakage. Check for leaks in the seating area using a noncorrosive leak detection solution. REPLACE THE VALVE IF THERE IS ANY INDICATION OF LEAKAGE. Never force a relief valve closed and continue to leave it in service. This could result in damage to the valve and possible rupture of the container or piping on which the valve is installed. 7. Corrosion and contamination. REPLACE THE VALVE IF THERE ARE ANY SIGNS OF CORROSION OR CONTAMINATION ON THE VALVE. 8. Moisture, foreign particles or contaminants in the valve. Foreign material such as paint, tar or ice in relief valve parts can impair the proper functioning of the valves. Grease placed in the valve body may harden over time or collect contaminants, thereby impairing the proper operation of the relief valve. DO NOT PLACE GREASE IN THE VALVE BODY, REPLACE THE VALVE IF THERE ARE ANY INDICATIONS OF MOISTURE OR FOREIGN MATTER IN THE VALVE. 2. Open weep holes. Dirt, ice, paint and other foreign particles can prevent proper drainage from the valve body. IF THE WEEP HOLES CANNOT BE CLEARED, REPLACE THE VALVE. 9. Corrosion or leakage at container connection. Check container to valve connection with a non-corrosive leak detection solution. REPLACE THE VALVE IF THERE IS ANY INDICATION OF CORROSION OR LEAKAGE AT THE CONNECTION BETWEEN THE VALVE AND CONTAINER. 3. Deterioration and corrosion on relief valve spring. Exposure to high concentrations of water, salt, industrial pollutants, chemicals and roadway contaminants could cause metal parts to fail. IF THE COATING ON THE RELIEF VALVE SPRING IS CRACKED OR CHIPPED, REPLACE THE VALVE. CAUTION: Never plug the outlet of a pressure relief valve. Any device used to stop the flow of a properly operating pressure relief valve that is venting an overfilled or overpressurized container - raises serious safety concerns! Replace Pressure Relief Valves In 10 Years Or Less The safe useful life of pressure relief valves can vary greatly depending on the environment in which they live. Relief valves are required to function under widely varying conditions. Corrosion, aging of the resilient seat disc and friction all proceed at different rates depending upon the nature of the specific environment and application. Gas impurities, product misuse and improper installations can shorten the safe life of a relief valve. Predicting the safe useful life of a relief valve obviously is not an exact science. The conditions to which the valve is subjected will vary widely and will determine its useful life. In matters of this kind, only basic guidelines can be suggested. For example, the Compressed Gas Association Pamphlet S-1.1 Pressure Relief Device Standards — Cylinders, section 9.1.1 requires all cylinders used in industrial motor fuel service to have the cylinder’s pressure relief valves replaced by new or unused relief valves within twelve years of the date of manufacture of cylinder and within each ten years thereafter. The LP-Gas dealer must observe and determine the safe useful life of relief valves in his territory. The valve manufacturer can only make recommendations for the continuing safety of the industry. D WARNING: Under normal conditions, the useful safe service life of a pressure relief valve is 10 years from the original date of manufacture. However, the safe useful life of the valve may be shortened and replacement required in less than 10 years depending on the environment in which the valve lives. Inspection and maintenance of pressure relief valves is very important. Failure to properly inspect and maintain pressure relief valves could result in personal injuries or property damage. For Additional Information Read: 1. CGA Pamphlet S-1.1 Pressure Relief Standards — Cylinders, Section 9.1.1. 2. ECII® Catalog L-500. 3. ECII® Warning # 8545-500. 4. NPGA Safety Pamphlet 306 “LP-Gas Regulator and Valve Inspection and Maintenance” and “LP-Gas Training Guidebooks”. 5. NFPA # 58, “Storage and Handling of Liquefied Petroleum Gases”. 6. NFPA # 59, “LP-Gases at Utility Gas Plants”. 7. ANSI K61.1 Safety Requirements for Storage and Handling of Anhydrous Ammonia. ® PRODUCTS D5 RegO® Pressure Relief Valves Requirements for Pressure Relief Valves Every container used for storing or hauling LP-Gas and anhydrous ammonia must be protected by a pressure relief valve. These valves must guard against the development of hazardous conditions which might be created by any of the following: • Hydrostatic pressures due to overfilling or the trapping of liquid between two points. • High pressures resulting from exposure of the container to excessive external heat. • High pressures due to the use of incorrect fuel. • High pressures due to improper purging of the container. Consult NFPA Pamphlet #58 for LP-Gas and ANSI #K61.1 for anhydrous ammonia, and/or any applicable regulations governing the application and use of pressure relief valves. Operation of Pressure Relief Valves Pressure relief valves are set and sealed by the manufacturer to function at a specific “start-to-discharge” pressure in accordance with regulations. This set pressure, marked on the relief valve, depends on the design requirement of the container to be protected by the relief valve. If the container pressure reaches the start-to-discharge pressure, the relief valve will open a slight amount as the seat disc begins to move slightly away from the seat. If the pressure continues to rise despite the initial discharge through the relief valve, the seat disc will move to a full open position with a sudden “pop”. This sharp popping sound is from which the term “pop-action” is derived. Whether the relief valve opens a slight amount or pops wide open, it will start to close if the pressure in the container diminishes. After the pressure has decreased sufficiently, the relief valve spring will force the seat disc against the seat tightly enough to prevent any further escape of product. The pressure at which the valve closes tightly is referred to as the “re-seal” or “blow-down” pressure. Generally, the re-seal pressure will be lower than the start-to-discharge pressure.The re-seal pressure can be, and in most cases is, adversely affected by the presence of dirt, rust, scale or other foreign particles lodging between the seat and disc. They interfere with the proper mating of the seat and disc and the pressure in the container will usually have to decrease to a lower pressure before the spring force embeds foreign particles into the resilient seat disc material and seals leak-tight. The degree by which the presence of dirt decreases the re-seal pressure, is, of course, dependent on the size of the interfering particles. Once particles have been trapped between the disc and seat, the start-to-discharge pressure is also affected. For example, the pressure relief valve will start-to-discharge at some pressure lower than its original start-to-discharge pressure. Again, the pressure at which the valve will start to discharge is dependent on the size of the foreign particles. In the case of a pressure relief valve that has opened very slightly due to a pressure beyond its start-to-discharge setting, the chances of foreign material lodging between the seat and disc is negligible although the possibility is always present. If the relief valve continues to leak at pressures below its start-to-discharge setting it must be replaced. Relief valves which have “popped” wide open must also be checked for foreign material lodged between the seat and disc, as well as for proper reseating of the seat and disc. Continued leakage at pressures below the start-to-discharge setting indicate the relief valve must be replaced. The pressure at which a pressure relief valve will start to discharge should never be judged by the reading of the pressure gauge normally furnished on the container. ® D6 PRODUCTS The reasons for this are two-fold: • If the relief valve is called upon to open, the resulting discharge produces an increased vaporization of the product in the container with the result that the liquid cools to a certain extent and the vapor pressure drops. A reading taken at this time would obviously not indicate what the pressure was when the relief valve opened. • The pressure gauges usually on most containers provide somewhat approximate readings and are not intended to provide an indication of pressure sufficiently accurate to judge the setting of the relief valve. Repair and Testing RegO® Pressure Relief Valves are tested and listed by Underwriters Laboratories, Inc., in accordance with NFPA Pamphlet #58. Construction and performance of RegO® Pressure Relief Valves are constantly checked at the factory by U.L. inspectors. Therefore, testing of RegO® Pressure Relief Valves in the field is not necessary. Never attempt to repair or change the setting of RegO ® Pressure Relief Valves. Any changes in settings or repairs in the field will void the UL® listing and may create a serious hazard. While the functioning of a pressure relief valve appears to be relatively simple, the assembly and test procedure used to manufacture these RegO® products is rather complex. Highly specialized test fixtures and specially trained personnel are necessary to attain proper relief valve settings. These fixtures and personnel are available only at the factory. Any pressure relief valve which shows evidence of leakage, other improper operation or is suspect as to its performance must be replaced immediately using approved procedures. Pipe-Away Adapters Pipe-away adapters are available for most RegO® Pressure Relief Valves, where it is required or desirable to pipe the discharge above or away from the container. Each adapter is designed to sever if excessive stress is applied to the vent piping – thus leaving the relief valve fully operative. Weep hole deflectors are available on larger relief valves. These deflectors provide protection against flame impinging on adjacent containers which could occur from ignition of LP-Gas escaping through the relief valve drain hole when the valve is discharging. Selection of RegO® Pressure Relief Valves For ASME Containers The rate of discharge required for a given container is determined by the calculation of the surface area of the container as shown in “Chart A” for LP-Gas and “Chart B” for anhydrous ammonia. See page D9. Setting - The set pressure of a pressure relief valve depends upon the design pressure of the container. Refer to NFPA Pamphlet #58 for more information. Selection of RegO® Pressure Relief Valves for DOT Containers To determine the proper relief valve required for a given DOT container, refer to the information shown with each pressure relief valve in the catalog. This information will give the maximum size (pounds water capacity) DOT container for which the relief valve has been approved. Setting - The standard relief valve setting for use on DOT cylinders is 375 PSIG. Ordering RegO® Pressure Relief Valves Part Number Explanation Products carrying an “A” or “AA” prefix contain no brass parts and are suitable for NH3. Hydrostatic relief valves carrying an “SS” prefix are of stainless steel construction and are suitable for use with NH3. The products are also suitable for use with LP-Gas service except relief valves carrying an “AA” prefix. These are of partial aluminum construction and are listed by U.L. for NH3 service only. When ordering RegO® Pressure Relief Valves, be sure you are certain that it will sufficiently protect the container as specified in the forewording information, NFPA Pamphlet #58 and any other applicable standards or specifications. All adapters, protective caps and deflectors must be ordered separately, unless specified otherwise. Safety Information — Relief Valves Don’t Last Forever Metal Seat RegO® Relief Valve for lift truck containers The internal spring is protected from external contamination but the other external parts must be protected with a cap. Circular rubber seat disc ring seats on brass shoulder approximately 3⁄64" wide. This article was prepared by the engineers of RegO® products, after technical consultation with valve manufacturers and other industry sources. Its purpose is to alert and remind the LP-Gas industry of the importance of proper maintenance of pressure relief valves. It applies most particularly to separate relief valves with emphasis on lift truck and motor fuel containers where the hazards of contamination are greatest. Since the beginning of our industry, manufacturers of equipment and distributors of LP-Gas have worked diligently to provide a safe environment for employees and consumers. The history of the industry testifies to the success of their efforts. But the industry is now entering its sixth decade and equipment installed years ago is failing because of age. Every year, additional equipment will fail unless it is replaced. Pressure relief valves are no exception. The valve manufacturers and LP-Gas dealers are naturally concerned about this situation. Causes of Relief Valve Failure A relief valve is designed to have a safe useful life of many years, but that life will vary greatly depending on the environment in which it “lives.” To attempt to estimate the safe useful life of a relief valve and the effect of environment on its performance, a brief discussion of the materials used and the nature of its performance should be helpful. Relief valve bodies are generally made of brass or steel. Springs are made from various spring wires which are plated or painted, or made of stainless steel. Valve seat discs are made of synthetic rubber compounds which will remain serviceable in an atmosphere of LPGas. Relief valve stems, guides, etc. are generally made from brass or stainless steel. Relief valves, over the years, may not function properly in several ways: • They may leak at pressures below the set pressure. • They may open and fail to properly reseat. • They may open at higher than the set pressure. These failures to function properly are due primarily to four “environmental’’ conditions: 1. Corrosion of metal parts (particularly springs) which result in the component parts failing to perform. 2. Deterioration of the synthetic rubber seat disc material. 3. Clogging or “cementing” of the movable relief valve components so that their movement is restricted. 4. Debris on the valve seat after the relief valve opens, effectively preventing the valve from reseating. Corrosion is caused by water, corrosive atmospheres of salt and industrial pollutants, chemicals, and roadway contaminants. High concentrations can attack the metal parts vigorously. No suitable metals are totally resistant to such corrosion. Synthetic rubber and seat disc materials can also be attacked by impurities in the gas and corrosive atmospheres, particularly those with sulphur dioxide. There are no suitable rubber materials which resist all contaminants. “Cementing” of relief valve parts has been caused by normal industrial atmospheres containing particles of dirt, iron oxide, metal chips, etc. combined with water, oil, or grease. Ice collecting in recessed valves could cause relief valves to fail to open. Paint and tar in relief valves also cause failure to function properly. D ® PRODUCTS D7 Safety Information — Relief Valves Don’t Last Forever Debris on valve seats which prevents reseating can occur whenever the valve collects material in the relief valve opening which is not blown out when the relief valve opens. Use of Protective Caps Inspection of Relief Valves Collection of debris would be prevented. Contamination caused by corrosive atmospheres would be reduced. Water collection in the valves would be eliminated. Relief valves protected with caps from the time of installation in the container would obviously have a much longer safe useful life, but they still should be replaced at some time because of the gradual deterioration of the rubber seat disc due to age alone. NFPA 58 requires that protective caps must be kept in place as a protective cover on some relief valves. This is a mandatory requirement on several types of relief valves. The fact that use of caps may make inspection more time consuming should not be viewed as a reason for either not using the caps, or not making required periodic inspections. In the event a relief valve has been used without the required cap, the relief valve should be thoroughly inspected and the required cap placed on the relief valve. If damage is noted to the relief valve, it should be replaced and the replacement valve should be capped. Relief valves with pipe-away adapters or deflectors used on lift truck containers have been found choked with debris. Inspection of relief valves with deflectors can only be accomplished by removing the deflector. Similarly, larger relief valves with vent stacks have been found choked with debris and water. Valves have failed because springs rusted through. The weep hole was plugged. It was obvious that the relief valves had not been inspected in many years. These conditions must be alleviated by periodic inspections and replacement of relief valves as needed. Unfortunately many of the above problems may not be easily observed because of the compact nature of some relief valve designs. A casual visual inspection of a relief valve may not necessarily disclose a potential hazard. On the other hand, a visual inspection will often disclose leakage, corrosion, damage, plugging and contamination. If additional light is required, a flashlight should be used. If there is any doubt about the condition of the valve, or if there is a suspicion that the valve has not been protected by a cap for some time, it should be replaced before refilling the container. Eye protection must be used when examining relief valves under pressure. Smaller Relief Valves The industry’s requirement for a small full-flow safety relief valve challenged design engineers some years ago: • The valve must be leakproof before operating and must reseat leakproof each time after each operation. The only known satisfactory seat disc materials to accomplish this have been special synthetic rubber compounds. • Valve discharge settings are relatively high and require high spring loads to keep the valve closed. • Because of the small interior diameter of the valve, the round metal seating area is small. All of these parameters may result in the development of a significant indentation in the rubber seat disc after some years. The seat disc may have a tendency to cling to the metal seat. This may result in the relief valve not opening at the set pressure as the seat disc ages. Test have been conducted on small LP-Gas relief valves of all the U.S. valve manufacturers. Valves over 10 years old were removed from service and tested to determine at what pressure the valves discharged. In many of the valves, the pressure required to open the valve exceeded the set pressure. Because of the critical importance of proper functioning of relief valves, common sense and basic safety practice dictate that small relief valves should be replaced in about 10 years. Some larger relief valves on bulk storage tanks can be replaced with rebuilt valves obtained from the manufacturers. Small relief valves cannot be rebuilt economically, thus, new valves are required. Most LP-Gas dealers find it impractical and costly to test relief valves and field repairing of relief valves is not sanctioned by the manufacturers, Underwriter's Laboratories, or ASME. ® D8 PRODUCTS Many of the problems that cause inoperative relief valves could be prevented if proper protective caps were kept in place at all times. Summary Recommendations Predicting the safe useful life of a relief valve is obviously not an exact science. The conditions to which the valve is subjected will vary widely and will largely control its life. In matters of this kind, only basic guidelines can be suggested. The LP-Gas dealer must observe and determine the safe useful life of relief valves in his territory. The valve manufacturers can only make recommendations for the continuing safety of the industry: 1. Make sure proper protective caps are in place at all times. Do not release a container for service or fill a container unless it has a protective cap in place. 2. Replace relief valves periodically, at least every 10 years. Every relief valve has the month and year of manufacture stamped on the valve. This is most particularly true of small separate relief valves. 3. Carefully inspect valves each time before the container is filled. Replace valves showing any signs of contamination, corrosion, damage, plugging, leakage, or any other problem. Eye protection must be used when examining relief valves under pressure. Chart A — Minimum Required Rate of Discharge for LP-Gas Pressure Relief Valves Used on Minimum required rate of discharge in cubic feet per minute of air at 120% of the maximum permitted start-to-discharge ASME Containers pressure for pressure relief valves to be used on containers other than those constructed in accordance with Interstate From NFPA Pamphlet #58, Appendix D (1986). Surface Area Sq. Ft. 20 or less 25 30 35 40 45 50 55 60 65 70 75 80 Flow Rate CFM Air 626 751 872 990 1100 1220 1330 1430 1540 1640 1750 1850 1950 Surface Area Sq. Ft. 85 90 95 100 105 110 115 120 125 130 135 140 145 Flow Rate CFM Air 2050 2150 2240 2340 2440 2530 2630 2720 2810 2900 2990 3080 3170 Commerce Commission specification. Surface Area Sq. Ft. 150 155 160 165 170 175 180 185 190 195 200 210 220 Flow Rate CFM Air 3260 3350 3440 3530 3620 3700 3790 3880 3960 4050 4130 4300 4470 Surface Area Sq. Ft. 230 240 250 260 270 280 290 300 310 320 330 340 350 Surface area =Total outside surface area of container in square feet. When the surface area is not stamped on the name plate or when the marking is not legible, the area can be calculated by using one of the following formulas: 1. Cylindrical container with hemispherical heads. Area (in sq. ft.) = overall length (ft.) x outside diameter (ft.) x 3.1416. 2. Cylindrical container with semi-ellipsoidal heads. Area (in sq. ft.) = [overall length (ft.) + .3 outside diameter (ft.)] x outside diameter (ft.) x 3.1416. 3. Spherical container. Area (in sq. ft.) = outside diameter (ft.) squared x 3.1416. Flow Rate CFM Air = Required flow capacity in cubic feet per minute of air at standard conditions, 60ºF. and atmospheric pressure (14.7 psia). The rate of discharge may be interpolated for intermediate values of surface Flow Rate CFM Air 4630 4800 4960 5130 5290 5450 5610 5760 5920 6080 6230 6390 6540 Surface Area Sq. Ft. 360 370 380 390 400 450 500 550 600 650 700 750 800 Flow Rate CFM Air 6690 6840 7000 7150 7300 8040 8760 9470 10170 10860 11550 12220 12880 Surface Area Sq. Ft. 850 900 950 1000 1050 1100 1150 1200 1250 1300 1350 1400 1450 Flow Rate CFM Air 13540 14190 14830 15470 16100 16720 17350 17960 18570 19180 19780 20380 20980 Surface Area Sq. Ft. 1500 1550 1600 1650 1700 1750 1800 1850 1900 1950 2000 Flow Rate CFM Air 21570 22160 22740 23320 23900 24470 25050 25620 26180 26750 27310 area. For containers with total outside surface area greater than 2000 square feet, the required flow rate can be calculated using the formula, Flow Rate in CFM Air = 53.632 A0.82. Where A = total outside surface area of the container in square feet. Valves not marked “Air” have flow rate marking in cubic feet per minute of liquefied petroleum gas. These can be converted to ratings in cubic feet per minute of air by multiplying the liquefied petroleum gas ratings by the factors listed below. Air flow ratings can be converted to ratings in cubic feet per minute of liquefied petroleum gas by dividing the air ratings by the factors listed below. Air Conversion Factors Container Type 100 125 150 175 200 Air Conversion Factor 1.162 1.142 1.113 1.078 1.010 Chart B — Minimum Required Rate of Discharge for Anhydrous Ammonia Pressure Relief Valves Used on ASME Containers Minimum required rate of discharge in cubic feet per minute of air at 120% of the maximum permitted start-to-disFrom ANSI K61.1-1981, Appendix A (1981). Surface Area Sq. Ft. 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Flow Rate CFM Air 258 310 360 408 455 501 547 591 635 678 720 762 804 845 885 Surface Area Sq. Ft. 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 Flow Rate CFM Air 925 965 1010 1050 1090 1120 1160 1200 1240 1280 1310 1350 1390 1420 1460 charge pressure for pressure relief valves to be used on containers other than those constructed in accordance with United States Department of Transportation cylinder specifications. Surface Area Sq. Ft. 170 175 180 185 190 195 200 210 220 230 240 250 260 270 280 Flow Rate CFM Air 1500 1530 1570 1600 1640 1670 1710 1780 1850 1920 1980 2050 2120 2180 2250 Surface Area Sq. Ft. 290 300 310 320 330 340 350 360 370 380 390 400 450 500 550 Surface area = Total outside surface area of container in square feet. When the surface area is not stamped on the name plate or when the marking is not legible, the area can be calculated by using one of the following formulas: 1. Cylindrical container with hemispherical heads. Area (in sq. ft.) = overall length (ft.) x outside diameter (ft.) x 3.146. 2. Cylindrical container with other than hemispherical heads. Area (in sq. ft.) = [overall length (ft.) + .3 outside diameter (ft.)] x outside diameter (ft.) x 3.1416. 3. Spherical container. Area (in sq. ft.) = outside diameter (ft.) squared x 3.1416. Flow Rate CFM Air 2320 2380 2450 2510 2570 2640 2700 2760 2830 2890 2950 3010 3320 3620 3910 Surface Area Sq. Ft. 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 1250 1300 Flow Rate CFM Air 4200 4480 4760 5040 5300 5590 5850 6120 6380 6640 6900 7160 7410 7660 7910 Surface Area Sq. Ft. 1350 1400 1450 1500 1550 1600 1650 1700 1750 1800 1850 1900 1950 2000 2050 Flow Rate CFM Air 8160 8410 8650 8900 9140 9380 9620 9860 10090 10330 10560 10800 11030 11260 11490 Surface Area Sq. Ft. 2100 2150 2200 2250 2300 2350 2400 2450 2500 Flow Rate CFM Air 11720 11950 12180 12400 12630 12850 13080 13300 13520 D Flow Rate CFM Air = Required flow capacity in cubic feet per minute of air at standard conditions, 60°F. and atmospheric pressure (14.7 psia). The rate of discharge may be interpolated for intermediate values of surface area. For containers with total outside surface area greater than 2,500 square feet, the required flow rate can be calculated using the formula, Flow Rate in CFM Air = 22.11 A0.82 where A = outside surface area of the container in square feet. Conversion Factor ft2 x 0.092 903 = m2 CFM x 0.028 317 = m3/min ft x 0.304 8 =m ® PRODUCTS D9 APPENDIX B DRAWINGS & TECHNICAL INFORMATION Appendix B This page intentionally left blank. DFV2-5.wmf WARNING P /N 50833 D IS CO N NE CT TH E S UP PLY CI RCU IT BEFO RE S ER VI CI N G TO PR EV EN T I NJ URY FRO M ELEC TRC I ALS HO CK WARNING P /N 50833 D IS CO N NE CT TH E S UP PLY CI RCU IT BEFO RE S ER VI CI N G TO PR EV EN T I NJ URY FRO M ELEC TRC I ALS HO CK Appendix B DFV 2.5 Equipment Drawing DFV7.wmf WARNING P /N 5083 3 D IS CO NN EC T TH E SU PP LY C IR CUI TB EFO RE S ERV I CI NG TO PR EV EN TI NJU R Y FRO M E LEC TRI C AL SH OC K WARNING D IS CO NN EC T TH E SU PP LY C IR CUI TB EFO RE P /N 5083 3 S ERV I CI NG TO PR EV EN TI NJU R Y FRO M E LEC TRI C AL SH OC K Appendix B DFV 7 Equipment Drawing DFV14.wmf WARNING P/ N 50833 DI S CO NN EC T THE S UP PLY CI RCUI TBE FORE SE RV I CI NG TO P RE VE NT I NJU RY FROM ELE CTRI CALS HOCK WARNING P/ N 50833 DI S CO NN EC T THE S UP PLY CI RCUI TBE FORE SE RV I CI NG TO P RE VE NT I NJU RY FROM ELE CTRI CALS HOCK Appendix B DFV 14 Equipment Drawing Appendix B DFV Electrical Schematic DFVelect.wmf ...Innovative liquid vaporizing and gas mixing solutions WARRANTY REGISTRATION Please copy the information from the data sheet supplied with your manual. Type of Equipment: Serial Number: ASDI Sales Order #: Order Date: Purchased By: To help us provide better service to you, please fill out this warranty registration form and retur n it to us. Keep a copy for your records. This will register your recent purchase and aide us in tracking the performance of your equipment. Please help us with a small amount of information about your company and about how you are using the equipment. Contact us via phone, fax, or email if you have a question, problem, or concern about your equipment. Please have the type of equipment and serial number available so we can give you accurate information. End Customer/Company Name: Address: City: Tel: State: Zip: Fax: Name of individual to contact for follow up information: When was the equipment put in service? Usage - Circle one: / / Base Load Standby System Peak Shaving Other please specify: Application - Circle one: Agriculture: Poultry Livestock Grain drying Commercial: Restaurant Hospital School Industrial : Construction Automotive Glass/ceramics Other: Please specify: Note: If you have more than one piece of our equipment, fill out one warranty sheet and staple the others to it, we’ll do the rest. 1140 NW 46 Street Se at tle Wash ing ton 98107 USA Tel: 206.789.5410 Fax: 206.789.5414 email: [email protected] Internet: www.algas-sdi.com Algas-SDI International, LLC 1140 NW 46th Street Seattle, Washington 98107 USA Ph.: 1.206.789.5410 Fax.: 1.206.789.5414 www.algas-sdi.com ">
/
Ladda ner
Bara en vänlig påminnelse. Du kan visa dokumentet här. Men viktigast av allt, vår AI har redan läst det. Den kan förklara komplexa saker på ett enkelt sätt, svara på dina frågor på vilket språk som helst och hjälpa dig att snabbt navigera även de längsta eller mest komplicerade dokumenten.
Annons