INSTALLATION AND OPERATION MANUAL
CLEK41EOC
COPPERLINE® VALUE KIT: POINT-TO-MULTIPOINT
ETHERNET-OVER-COAX EXTENDER
This manual serves the following
ComNet Model Numbers:
CLEK41EOC:
1 × CLEL4EOC
4 × CLER1EOC/M
The ComNet Value CLEK41EOC features four remote 10/100 Mbps single-channel units and a single four-channel local unit in a pre-packaged kit. Perfect for applications that face density challenges. The four-channel units will fit into any
ComNet product rack. The four individual small-sized remote units can be placed up to 1,200 feet (400 meters) from the four channel local unit. Power supplies included. A DIP Switch allows configurable selection of 10 Mbps or 100 Mbps speed these units are simple to install. This CopperLine® Value kit provides five units with power supplies.
Bi-color (Red/Green) LED indicators are provided for rapidly ascertaining equipment operating status. Step 5 on Page 4 describes the LED indicators for each light on the unit.
The CLEL4EOC four channel unit is interchangeable between stand-alone or card mount configurations, or may be DIN-rail mounted by the addition of ComNet model DINBKT1 or DINBKT4 adaptor plate. The CLER1EOC/M mini units are standalone, or may be DIN-rail mounted by the addition of ComNet model DINBKT4 adaptor. See Figures A and B on Page 5 for mounting instructions.
TECH SUPPORT: 1.888.678.9427
INS_CLEK41EOC_REV– 10/27/11 PAGE 1
INSTALLATION AND OPERATION MANUAL
FIGURE 1 – CLER1EOC/M REMOTE MINI SINGLE CHANNEL COAX UNIT
Operating Power: 12 VDC
OR 24 VAC
Power Consumption: 1.5 W
ETHERNET
CLEK41EOC
EXT DISTANCE
Black w/ White
Stripe (AC or DC–)
Black (AC or DC+)
FIGURE 2 – CLER1EOC/M REMOTE MINI SINGLE CHANNEL COAX UNIT
10/100 data rate DIP switch
Switch
10/100
UP
10 Mbps
DOWN
100 Mbps
See Installation Instructions for more information
GREEN
YELLOW
OFF
Remote Mini Single Channel Coax Indicating LEDs
POWER
Power Applied
–
Power Off
LINK
10Mbps
100Mbps
No Link
Ethernet Link
–
Link Established
No Link
Ethernet Activity
Activity Detected
–
No Activity
Ethernet
Activity
Ethernet
Link
TECH SUPPORT: 1.888.678.9427
INS_CLEK41EOC_REV– 10/27/11 PAGE 2
INSTALLATION AND OPERATION MANUAL
FIGURE 3 – CLFE4EOC LOCAL FOUR CHANNEL SURFACE OR RACK MOUNT COAX UNIT
CLEK41EOC
CH1 ETHERNET
CH2 ETHERNET
CH3 ETHERNET
CH4 ETHERNET
CH1 EXT
DISTANCE
CH2 EXT
DISTANCE
CH3 EXT
DISTANCE
CH4 EXT
DISTANCE
Black w/ White
Stripe (DC–)
Black (DC+)
Operating Power: 9 to 15 VDC
Power Consumption: 5W
FIGURE 4 – CLFE4EOC LOCAL FOUR CHANNEL SURFACE OR RACK MOUNT COAX UNIT
GREEN
YELLOW
OFF
PWR
Power Applied
–
Power Off
Indicating LEDs
EXT LINK (1 - 4)
10Mbps
100Mbps
No Link
Ethernet Link
–
Link Established
No Link
Ethernet Activity
Activity Detected
–
No Activity
Ethernet
Activity
Ethernet
Link
10/100 data rate DIP switch
See Installation Instructions, Step 1
TECH SUPPORT: 1.888.678.9427
INS_CLEK41EOC_REV– 10/27/11 PAGE 3
INSTALLATION AND OPERATION MANUAL CLEK41EOC
INSTALLATION INSTRUCTIONS
1 - SET 10/100 SWITCH
Locate the 10/100 data rate DIP switch on the unit.
Set the data rate according to bandwidth required.
NOTE: The data rate must be set the same on both the local and all the remote units.
2 - CONNECT EXTENDED WIRING
Connect Extended Distance Port to field wiring.
3 - CONNECT NETWORK WIRING
Using CAT5/5e, connect Local unit to network and Remote unit to camera.
4 - CONNECT POWER
Connect power to unit per the following table:
Unit
CLER1EOC/M
Power Connections per Use Case
Local Power
12 VDC or 24 VAC
CLEL4EOC 9 to 15 VDC (9 VDC † when in a C1 or C2 rack)
† Contact ComNet pre-sales support, or refer to the appropriate installation and operation manual when configuring and specifying power for a deployment.
5 - VERIFY FUNCTIONALITY
See LED tables and Troubleshooting Guide if corrective action is needed.
TROUBLESHOOTING GUIDE
Problem
Indicating LEDs not lighting
No Communication
Bad Video
Steps to Take
Check that power is properly applied to the unit
Check Ethernet Link LEDs, Extended Link LEDs, All Connections, and 10/100 switches are set properly. Verify that Local units are installed at the head end and that Remote units are installed in the field.
Make sure Data Rate Switch is set properly.
TECH SUPPORT: 1.888.678.9427
INS_CLEK41EOC_REV– 10/27/11 PAGE 4
INSTALLATION AND OPERATION MANUAL
PRODUCT DIMENSIONS
The CLER1EOC/M is supplied as a standalone/surface mount (mini size) module. The CLEL4EOC is supplied as a standalone/surface/ rack (ComFit) module.
INSTALLATION CONSIDERATIONS
These units are supplied as Standalone/Rack mounted module.
Units should be installed in dry locations protected from extremes of temperature and humidity.
WARNING: Unit is to be used with a Listed Class 2 power supply.
IMPORTANT SAFEGUARDS:
A) Elevated Operating Ambient - If installed in a closed or multiunit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (T specified by the manufacturer.
ma
)
B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.
FIGURE A
Dimensions are for a mini size module
FIGURE B
Dimensions are for a ComFit module
CLEK41EOC
3 CORPORATE DRIVE | DANBURY, CONNECTICUT 06810 | USA | T: 203.796.5300
| F: 203.796.5303
| TECH SUPPORT: 1.888.678.9427
8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE | T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | [email protected]
© 2015 Communication Networks. All Rights Reserved. “ComNet,” the “ComNet Logo,” “CopperLine,” and the “CopperLine Logo” are registered trademarks of Communication Networks.
TECH SUPPORT: 1.888.678.9427
INS_CLEK41EOC_REV– 10/27/11 PAGE 5