Comnet CL(L,R)FE(X)POE(C,U) Series manual

Add to My manuals
14 Pages

advertisement

Comnet CL(L,R)FE(X)POE(C,U) Series manual | Manualzz

INSTALLATION AND OPERATION MANUAL

CL(L,R)FE(X)POE(C,U) Series

ETHERNET-OVER-COPPER EXTENDER WITH 30W PSE POE+

This manual serves the following

ComNet Model Numbers:

CLLFE1POEC

CLRFE1POEC

CLLFE1POEU

CLRFE1POEU

CLLFE4POEC

CLRFE4POEC

CLLFE4POEU

CLRFE4POEU

CLLFE8POEC

CLLFE8POEU

CLLFE16POEC

CLLFE16POEU

The ComNet ™ CopperLine® Ethernet over copper line supports up to sixteen channels of 10/100Mbps Ethernet with PoE+ Power Injection and Pass-through PoE+ over twisted pair cable (CAT-5, UTP) or over coax. With the ability to connect directly to a

PoE+ switch, or the ability to generate PoE+ power with a 48 to 56 V input to either the Local or Remote ends, these units provide the ultimate flexibility for extending a powered device (PD) over long distance copper. A complete set includes both a Local and Remote module. Remote units are available in small package sizes that include one or four channels, and Local modules are available in the same packages as well as a

1RU rack for larger channel counts.

Bi-color (Red/Green) LED indicators are provided for rapidly ascertaining equipment operating status. Table 2 on Page 11 describes the LED indicators for each light on the unit.

The CLLFE8POE(C,U) and CLLFE16POE(C,U) are 1RU rack mountable units. The

CL(L,R)FE4POE(C,U) units are interchangeable between stand-alone or card mount configurations, or may be DIN-rail mounted by the addition of ComNet model

DINBKT1 or DINBKT4 adaptor plate. The CL(L,R)FE1POE(C,U) units are stand-alone, or may be DIN-rail mounted by the addition of ComNet model DINBKT4 adaptor.

See Figures A through C on Page 14 for mounting instructions.

TECH SUPPORT: 1.888.678.9427

INS_CL(L,R)FE(X)POE(C,U)_REV– 10/27/11 PAGE 1

INSTALLATION AND OPERATION MANUAL

FIGURE 1 – CLLFE1POEC SINGLE CHANNEL COAX LOCAL UNIT

ETHERNET

CL(L,R)FE(X)POE(C,U) SERIES

Pass-Through: PoE power, or optional:

9 to 36 VDC or 24 VAC, 1.5 W

Power Injection: 48 to 56 VDC, 30W

EXT DISTANCE

POE–

POE+

Black (AC or DC–)

Black w/ White Stripe (AC or DC+)

FIGURE 2 – CLRFE1POEC SINGLE CHANNEL COAX REMOTE UNIT

ETHERNET

Pass-Through: PoE power, or optional:

9 to 36 VDC or 24 VAC, 1.5 W

Power Injection: 48 to 56 VDC, 30W

EXT DISTANCE

POE–

POE+

Black (AC or DC–)

Black w/ White Stripe (AC or DC+)

FIGURE 3 – CL(L,R)FE1POEC SINGLE CHANNEL COAX UNITS

Switch

10/100

UP

10 Mbps

DOWN

100 Mbps

See Installation Instructions for more information

10/100 data rate DIP switch

TECH SUPPORT: 1.888.678.9427

INS_CL(L,R)FE(X)POE(C,U)_REV– 10/27/11 PAGE 2

INSTALLATION AND OPERATION MANUAL

FIGURE 4 – CLLFE1POEU SINGLE CHANNEL UTP LOCAL UNIT

ETHERNET

CL(L,R)FE(X)POE(C,U) SERIES

Pass-Through: PoE power, or optional:

9 to 36 VDC or 24 VAC, 1.5 W

Power Injection: 48 to 56 VDC, 30W

EXT DISTANCE

POE–

POE+

Black (AC or DC–)

Black w/ White Stripe (AC or DC+)

FIGURE 5 – CLRFE1POEU SINGLE CHANNEL UTP REMOTE UNIT

ETHERNET

Pass-Through: PoE power, or optional:

9 to 36 VDC or 24 VAC, 1.5 W

Power Injection: 48 to 56 VDC, 30W

EXT DISTANCE

POE–

POE+

Black (AC or DC–)

Black w/ White Stripe (AC or DC+)

FIGURE 6 – CL(L,R)FE1POEU SINGLE CHANNEL UTP UNITS

Wire pair DIP switch

10/100 data rate DIP switch

TECH SUPPORT: 1.888.678.9427

Switch

10/100

Wire Pair

UP

10 Mbps

4 Pair

DOWN

100 Mbps

1 Pair

See Installation Instructions for more information

INS_CL(L,R)FE(X)POE(C,U)_REV– 10/27/11 PAGE 3

INSTALLATION AND OPERATION MANUAL CL(L,R)FE(X)POE(C,U) SERIES

FIGURE 7 – CL(L,R)FE4POEC FOUR CHANNEL SURFACE OR RACK MOUNT COAX UNIT

CH1

ETHERNET

CH2

ETHERNET

CH3

ETHERNET

CH4

ETHERNET

CH1 EXT

DISTANCE

CH2 EXT

DISTANCE

CH3 EXT

DISTANCE

CH4 EXT

DISTANCE

POE–

POE+

Black (DC–)

Black w/ White Stripe (DC+)

Pass-Through Mode 12 to 15 VDC, 6 W

Power Injection Mode 48 to 56 VDC, 120W

FIGURE 8 – CL(L,R)FE4POEC FOUR CHANNEL SURFACE OR RACK MOUNT COAX UNIT

CLLFE4POEC Local Unit Front Panel CLRFE4POEC Remote Unit Front Panel CL(L,R)FE4POEC Rear Panel

10/100 data rate

DIP switch

See Installation

Instructions, Step 1

TECH SUPPORT: 1.888.678.9427

10/100 data rate

DIP switch

See Installation

Instructions, Step 1

INS_CL(L,R)FE(X)POE(C,U)_REV– 10/27/11 PAGE 4

INSTALLATION AND OPERATION MANUAL CL(L,R)FE(X)POE(C,U) SERIES

FIGURE 9 – CL(L,R)FE4POEU FOUR CHANNEL SURFACE OR RACK MOUNT UTP UNIT

CH1

ETHERNET

CH2

ETHERNET

CH3

ETHERNET

CH4

ETHERNET

CH1 EXT

DISTANCE

CH2 EXT

DISTANCE

CH3 EXT

DISTANCE

CH4 EXT

DISTANCE

POE–

POE+

Black (DC–)

Black w/ White Stripe (DC+)

Pass-Through Mode 12 to 15 VDC, 6 W

Power Injection Mode 48 to 56 VDC, 120W

FIGURE 10 – CL(L,R)FE4POEU FOUR CHANNEL SURFACE OR RACK MOUNT UTP UNIT

CLLFE4POEU Local Unit CLRFE4POEU Remote Unit CL(L,R)FE4POEU Rear

Wire pair DIP switch

See Installation Instructions, Step 2

10/100 data rate DIP switch

See Installation Instructions, Step 1

TECH SUPPORT: 1.888.678.9427

INS_CL(L,R)FE(X)POE(C,U)_REV– 10/27/11 PAGE 5

INSTALLATION AND OPERATION MANUAL

FIGURE 11 – CLLFE8EOC MULTICHANNEL RACK COAX UNITS

CL(L,R)FE(X)POE(C,U) SERIES

Black w/ White Stripe (DC+)

Black (DC–)

POE–

Pass-Through

POE+

12 to 15 VDC, 24 W

Power Injection 48 to 56 VDC, 480 W

Data rate DIP switch

See Installation

Instructions, Step 1

Data rate DIP switch

See Installation

Instructions, Step 1

TECH SUPPORT: 1.888.678.9427

INS_CL(L,R)FE(X)POE(C,U)_REV– 10/27/11 PAGE 6

INSTALLATION AND OPERATION MANUAL

FIGURE 12 – CLLFE8EOU MULTICHANNEL RACK UTP UNITS

CL(L,R)FE(X)POE(C,U) SERIES

Black w/ White Stripe (DC+)

Black (DC–)

POE–

Pass-Through

POE+

12 to 15 VDC, 24 W

Power Injection 48 to 56 VDC, 480 W

Data rate DIP switch

See Installation

Instructions, Step 1

Wire pair DIP switch

See Installation

Instructions, Step 2

Data rate DIP switch

See Installation

Instructions, Step 1

Wire pair DIP switch

See Installation

Instructions, Step 2

TECH SUPPORT: 1.888.678.9427

INS_CL(L,R)FE(X)POE(C,U)_REV– 10/27/11 PAGE 7

INSTALLATION AND OPERATION MANUAL

FIGURE 13 – CLLFE16EOC MULTICHANNEL RACK COAX UNITS

CL(L,R)FE(X)POE(C,U) SERIES

Black w/ White Stripe (DC+)

Black (DC–)

POE–

Pass-Through

POE+

12 to 15 VDC, 24 W

Power Injection 48 to 56 VDC, 480 W

Data rate DIP switch

See Installation

Instructions, Step 1

Data rate DIP switch

See Installation

Instructions, Step 1

Data rate DIP switch

See Installation

Instructions, Step 1

Data rate DIP switch

See Installation

Instructions, Step 1

TECH SUPPORT: 1.888.678.9427

INS_CL(L,R)FE(X)POE(C,U)_REV– 10/27/11 PAGE 8

INSTALLATION AND OPERATION MANUAL

FIGURE 14 – CLLFE16EOU MULTICHANNEL RACK UTP UNITS

CL(L,R)FE(X)POE(C,U) SERIES

Black w/ White Stripe (DC+)

Black (DC–)

POE–

Pass-Through

POE+

12 to 15 VDC, 24 W

Power Injection 48 to 56 VDC, 480 W

Wire pair DIP switch

See Installation

Instructions, Step 2

Data rate DIP switch

See Installation

Instructions, Step 1

Wire pair DIP switch

See Installation

Instructions, Step 2

Data rate DIP switch

See Installation

Instructions, Step 1

Wire pair DIP switch

See Installation

Instructions, Step 2

Data rate DIP switch

See Installation

Instructions, Step 1

Wire pair DIP switch

See Installation

Instructions, Step 2

Data rate DIP switch

See Installation

Instructions, Step 1

TECH SUPPORT: 1.888.678.9427

INS_CL(L,R)FE(X)POE(C,U)_REV– 10/27/11 PAGE 9

INSTALLATION AND OPERATION MANUAL

APPLICATION DIAGRAMS

Note: Coaxial applications use CL(L,R)FE(X)POEC modules; UTP applications use CL(L,R)FE(X)POEU modules.

PoE Pass-Through Mode

PoE

Ethernet Switch or Midspan

Remote PoE Injection Mode

Ethernet

Switch

Local

CLLFE1POE(C,U)

Local

CLLFE1POE(C,U)

12 to 15 VDC

CL(L,R)FE(X)POE(C,U) SERIES

Ethernet Connection

Extended Connection

PoE Power

Remote

CLRFE1POE(C,U) PoE Camera

Remote

CLRFE1POE(C,U)

48 to 56 VDC

PoE Camera

Local PoE Injection Mode

Ethernet

Switch

Local

CLLFE4POE(C,U)

48 to 56 VDC

Remote

CLRFE1POE(C,U)

CLRFE1POE(C,U)

PoE Camera

PoE Camera

Multichannel PoE Application

PoE

Ethernet Switch or Midspan

12 to 15 VDC

Local

CLLFE4POE(C,U)

CLLFE8POE(C,U)

Remote

CLRFE1POE(C,U)

CLRFE1POE(C,U)

CLRFE4POE(C,U)

12 to 15 VDC

CLRFE1POE(C,U)

CLRFE1POE(C,U)

CLRFE1POE(C,U)

PoE Camera

PoE Camera

PoE Camera

PoE Camera

PoE Camera

PoE Camera

PoE Camera

12 to 15 VDC

IMPORTANT NOTE. PLEASE READ. The applications are shown as general representations only and are not intended to show detailed network topologies. Your actual network will differ, requiring changes or perhaps additional network equipment to accommodate the systems as illustrated. Please contact ComNet’s Design Center to discuss your specific requirements.

TECH SUPPORT: 1.888.678.9427

INS_CL(L,R)FE(X)POE(C,U)_REV– 10/27/11 PAGE 10

INSTALLATION AND OPERATION MANUAL CL(L,R)FE(X)POE(C,U) SERIES

INSTALLATION INSTRUCTIONS

1 - SET DATA RATE DIP SWITCHES

Locate the 10/100 data rate DIP switch on the unit.

Set the data rate according to bandwidth required.

NOTE: The data rate must be set the same on both the local and remote units.

2 - SET WIRE PAIR DIP SWITCHES (UTP MODELS ONLY, FOR COAX MODELS SKIP TO STEP 3)

Locate the wire pair DIP switch on the unit.

Set the pair according to number of twisted wire pairs used (1 or 4).

NOTE: The number of pairs selected must be set the same on both the local and remote units.

PoE Pass-Through mode is only available in 4-pair mode.

3 - CONNECT EXTENDED WIRING

Connect Extended Distance Port to field wiring.

4 - CONNECT NETWORK WIRING

Using CAT5/5e, connect Local unit to network and Remote unit to camera.

5 - CONNECT POWER

Connect power to unit per the following table:

Unit

CL(L,R)FE1POE(C,U)

Local Power

Power Connections per Use Case

Pass-Through PoE

9 to 36 VDC or 18 to 32 VAC

Connect to AC/DC- and AC/DC+

No external power required

CL(L,R)FE4POE(C,U)

12 to 15 VDC (9 VDC † when in a C1 or C2 rack)

Connect to DC- and DC+

CLLFE8POE(C,U)

CLLFE16POE(C,U)

12 to 15 VDC

Connect to DC- and DC+

For 1-pair mode, use the first pair of pins (pins 1 and 2) of the

“Extended Ethernet” RJ-45 port.

PoE Injection

48 to 56 VDC

Connect to POE- and POE+

48 to 56 VDC

Connect to POE- and POE+

48 to 56 VDC

Connect to POE- and POE+

8 to 15 VDC

Connect to DC- and DC+

Note: Use only one of the two power connectors, based on the power requirements of your application.

Contact ComNet pre-sales support, or refer to the appropriate installation and operation manual when configuring and specifying power for a deployment.

6 - VERIFY FUNCTIONALITY

See LED table below and Troubleshooting Guide if corrective action is needed.

Indicating LEDs

GREEN

PWR

Power Applied

POE

PoE Applied

Link (Ethernet Port)

Activity (Ethernet Port)

EXT LNK

10M or 100M

YELLOW

OFF

BLINK

Power Off

No PoE Present

Link Detected

No Link

Data Activity

Link Detected

No Link

Data Activity

APPLICATION NOTES

1 Mixed PoE and Non-PoE systems can be implemented.

2 All Non-PoE systems require local power.

3 PoE power injection can be applied to Local or Remote units.

4 Single Channel units (CL(L,R)FE1POE(C,U)) require power for all Non-PoE applications. Local power can be used in PoE application to minimize PoE consumption.

5 Lower data rates generally provide longer operating distances.

6 Rack units (CLLFE8POE(C,U), CLLFE16POE(C,U)) are pre-configured for Local (L), therefore only speed switch and pair select (UTP only) are configurable. Any unit connected to one of these rack units via an extended distance port, must be configured as Remote (R) for proper operation.

7 The Extended Distance ports are suitable for connection to outside Plant leads (TNV-1) only when unit is operated in power pass through mode or the unit is operating in non-POE mode and powered by local 12VDC only and the equipment connected to the Ethernet ports has been evaluated for connection to outside plant leads.

TECH SUPPORT: 1.888.678.9427

INS_CL(L,R)FE(X)POE(C,U)_REV– 10/27/11 PAGE 11

INSTALLATION AND OPERATION MANUAL CL(L,R)FE(X)POE(C,U) SERIES

APPROXIMATE MAXIMUM EXTENDED DISTANCES 1

Media

Camera Data Rate

Source Power

Non-PoE Camera 1

Remote Injection

PoE CLASS2 Camera (6.5W) 1

PoE CLASS3 Camera(13W) 1

(10W in Pass-Through mode)

PoE CLASS4 Camera (25.5W) 1

(22W in Pass-Through mode)

COAX - RG59/U n/a

10M

15W

5,000 ft

1,524 m

5,000 ft

1,524 m

3,000 ft

914 m

850 ft

259m

30W

335 ft

102m n/a

100M

15W

2,000 ft

610 m

2,000 ft

610 m

2,000 ft

610 m

850 ft

259m

30W

335 ft

102m

UTP - 4 pair

10M

15W

3,000 ft

914 m

3,000 ft

914 m

3,000 ft

914 m

850 ft

259m

30W

100M

15W

2,000 ft

610 m

2,000 ft

610 m

610 m

(2,000 ft)

850 ft

259m

30W n/a n/a n/a n/a

10M

UTP - 1 pair

100M

3,000 ft

914 m

1,000 ft

305 m

1 Distance figures are based on a 50V PSE PoE power source, and external power supplies for the extenders. Distance figures are obtained using in-house testing mirroring installations. Factors such as coaxial/copper cable quality, the number of connectors/splices in the cable run, the use of PoE, and environmental conditions encountered within the installation may affect the actual transmission distance, and should be taken into consideration.

² PoE over extended distance is not available in 1 Pair mode. Remote PoE injection is required for this case.

TROUBLESHOOTING GUIDE

Problem

Indicating LEDs not lighting

No Communication

Bad Video

PoE Not Supplied to PD

Units not reaching estimated max distances over COAX or CAT5/UTP

Steps to Take

Non-PoE: Check that power is properly applied to the unit using the correct connector pair.

Pass-through mode: Check that PoE source is enabled from the network switch.

Check Ethernet Link LEDs, Extended Link LEDs, All Connections, Local/Remote and 10/100 switches are set properly.

Verify that Local units are installed at the head end and that Remote units are installed in the field.

Make sure Data Rate Switch is set properly, and the extended distance is within specifications (see Table “Approximate

Maximum Extended Distances”).

Make sure extended distance is within specifications (see Table “Approximate Maximum Extended Distances”).

Check extended distance cable and connections. Try connection on a short cable to eliminate possibility of faulty cabling.

Check that the extended distance wire is connected to Extended Distance Port.

Verify that there is no additional equipment (e.g. surge protector) on the Extended Link. The cable should be continuous from end to end, with no active components.

INSTALLATION CONSIDERATIONS

These units are supplied as Standalone/Rack mounted module. Units should be installed in dry locations protected from extremes of temperature and humidity.

WARNING: Unit is to be used with a Listed Class 2 power supply.

IMPORTANT SAFEGUARDS:

A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.

B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.

TECH SUPPORT: 1.888.678.9427

INS_CL(L,R)FE(X)POE(C,U)_REV– 10/27/11 PAGE 12

INSTALLATION AND OPERATION MANUAL CL(L,R)FE(X)POE(C,U) SERIES

ATTACHING THE FERRITE CORE TO THE POWER CORD OF THE UNIT

(Ferrite core not included, must be purchased separately)

When using 24VAC or 48VDC Power Supplies

Attaching the ferrite core to the power cord of the unit helps prevent RF interference from radio signals.

1. Pull the fixing tab of the ferrite core to open it.

2. Make three loops around the core with the power cable of the unit.

3. Attach the ferrite core to the unit power cord as shown and press it until it clicks.

Recommended part is Wurth Part 742 711 32 S

(Not included). Equivalent parts may be substituted.

LOOPING THE POWER CABLE AROUND THE FERRITE CORE

Lift up to release the lock and open the core.

Closed Open

Make three loops around the core with the power cable.

Start winding 5 to 10 cm (2 to 3.9 in) away from the power connection.

Close the lock. You may now operate the unit according to instructions.

TECH SUPPORT: 1.888.678.9427

INS_CL(L,R)FE(X)POE(C,U)_REV– 10/27/11 PAGE 13

INSTALLATION AND OPERATION MANUAL CL(L,R)FE(X)POE(C,U) SERIES

PRODUCT DIMENSIONS

The CL(L,R)FE1POE(C,U) is supplied as a standalone/surface mount (small size) module. The CL(L,R)FE4POE(C,U) is supplied as a standalone/surface/ rack (ComFit) module. The CLLFE8POE(C,U) and CLLFE16POE(C,U) are supplied as 19 wide rack units for standalone or rack installation.

FIGURE A

Dimensions are for a small size module

0.8cm

[0.31in]

0.4cm

[0.16in]

4.19cm

[1.65in]

0.62cm

[0.24in]

FIGURE B

Dimensions are for a ComFit module

13.2cm

[5.2in]

11.9cm

[4.7in]

6.37cm

[2.50in]

8.38cm

[3.3in]

2.7cm

[1.06in]

FIGURE C

Dimensions are for a 19″ Rack Unit

1.9cm

[0.75in]

44.45cm

[17.50in]

0.63cm

[0.25in]

2.75cm

[1.1in]

7.5cm

[2.9in]

15cm

[5.9in]

1.9cm

[0.75in]

48.26cm

[19.0in]

15.44cm

[6.08in]

4.37cm

[1.72in]

3 CORPORATE DRIVE | DANBURY, CONNECTICUT 06810 | USA | T: 203.796.5300

| F: 203.796.5303

| TECH SUPPORT: 1.888.678.9427

| [email protected]

8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE | T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | [email protected]

© 2016 Communication Networks. All Rights Reserved. “ComNet,” the “ComNet Logo,” “CopperLine,” and the “CopperLine Logo” are registered trademarks of Communication Networks.

INS_CL(L,R)FE(X)POE(C,U)_REV– 10/27/11 PAGE 14

advertisement

Related manuals

advertisement