Trim-Plus 1503TP air compressor Operator's Manual
पीडीएफ
दस्तावेज़
विज्ञापन
विज्ञापन
PERATOR'S MANUAL
Trim-Plus
Gallon Oil Free Portable Air Compressor
1503TP
qe
Vta ea
Your air compressor has been engineered and manufactured to high standard for dependability, ease of opera-
tion, and operator safety. When properly cared for, it will give you years of rugged, trouble-free performance.
A WARNING: To reduce the risk of injury, the user must read and understand the operator's manual before using
this product.
Thank you for buying a product.
SAVE THIS MANUAL FOR FUTURE REFERENCE
1503TP 04/09
o
PERRI]
IMPORTANT
This unit was fully tested and inspected prior to shipment and will operate properly when instructions are followed. Refer to your owners manual for basic
troubleshooting.
NOTICE
+ Air compressor will automatically shut off when maximum PSI is reached. When the tank pressure drops to the cut in pressure (low pressurej and the anvoff
switch is in the ON position. the unit will automatically restart.
+ On occasion. maximum pressure in tank will remain until next use thus resulting ina sense of no power. {See builet above}
* To avoid power loss, overheating ang ensure power, use additional air hose rather than extension cords.
* lt js the consumer's responsability to drain of lubed units prior to shipment ta meet ICC, state and local fire regulations.
TABLE OF CONTENTS
| Mínjio o[?ori(e) ¡O OTE rasa aera bs 2
E General Safety Rules ......................eeeeerenier ie eno nene ener erAerrarenecrarerereerIrrarenrereeveret traer rtean rre rraNoracOOUeoneceaneceanes 3-4
N Specific Safety Rules ...............e een ire bran SNA SES HSE 5
№ SYMDOIS..............érensaraerrrera pere ee paneamee seras n eee nee a dE rncenenererreenarererenacearErarenraeaI TONE FAR rrenCeNANenDeCINenTecAT NEC enmanevaroranaa 6-7
Sn 8
E Glossary of Terms ........... eee UU OOP PUPP OPN OOTP STRIPS SEE 9
N reee rrecereenvarererTcnEa Free ARENA NUAN TOcteCENe rr enenoncatIr re PrCUNDEEA VEnVaNEN een? 9
№ Feature OOO TI 10-11
1 ane nra rar ss Our A ESA raNa rare Eee Ur A AE ENT EEE R en FUNCerVeNtrCrNrrErerENeN One rorerAeraarmUar 11-12
E Transport and HTN... cere err reser ESSENCE ER EE 13
BE Operation... earn inner enenee enero er e EDO ree recacanrenerearecarecrenarenravereterrecararere reee nncrc are Nerranvrnenan eee ren. 14-15
№ Maintenance ............... eee er ree ose, Dre ere arene ea ee esas rab sas eth neh Eada rare raneraDOrPOenrnevneramen rave De racINNrenRe reterneneree. 16
J Ce TT a1 =: a Tole] i DOO OPO POP TO TROT P UPTURN ATP RIPPIN 17
~ INTRODUCTION
PRODUCT FOR CONSUMER USE ONLY. Not intended for commercial use.
A DANGER
This compressor/pump is not equipped and should not be used to supply breathing quality air. Additional equip-
ment would be necessary to properly filter and purify the air to meet minimal specifications for Grade D breathing
as described in Compressed Gas Association Commodity Specification G 7.1 - 1966, OSHA 29 CFR 1910.134.
Compressed Gas Association, 4221 Walney Road, Fifth Floor, Chantilly, VA 20151-2823, (703) 788-2700,
www.cganet.com. Any such additional equipment has not been examined and no implication of proper use for breath-
ing air is intended or implied.
If this compressor is altered in any way, existing warranties shall be voided. Manufacturer disclaims any liabilities
whatsoever for any loss, personal injury, or damage.
GENERAL SAFETY RULES
A WARNING:
Read and understand all instructions. Failure to fol-
low all instructions listed below may result in electric
shock, fire, and/or serious personal injury.
SAVE THESE INSTRUCTIONS
WORK AREA
NM Keep your work area clean and well lit. Clutiered
benches and dark areas invite accidents. Floor must
not be slippery from wax or dust.
a Do not operate power tools in explosive atmo-
spheres, such as in the presence of flammable lig-
vids, gases, or dust. Power tools create sparks which
may ignite the dust or fumes.
u Keep bystanders, children, and visitors away while
operating tools. Distractions can cause you to lose
control.
Wm Operate air compressor In an open area at least
18 in. away from any wall or object that could re-
strict the flow of fresh air to ventilation openings.
ELECTRICAL SAFETY
E Avoid body contact with grounded surfaces such as
pipes, radiators, ranges, and refrigerators. There is an
increased risk of electric shock if your body is grounded.
HN Don't expose power tools to rain or wet conditions.
Water entering a power tool will increase the risk of
electric shock,
E Do not abuse the cord. Never use the cord to carry
the tool or pull the plug from an outlet. Keep cord
away from heat, oil, sharp edges, or moving parts.
Replace damaged cords immediately. Damaged
cords increase the risk of electric shock.
E When operating a power tool outside, use an outdoor
extension cord marked "W-A" or “W?”, These cords
are rated for outdoor use and reduce the risk of electric
shock.
PERSONAL SAFETY
NM Eye protection which conforms to ANSI specifica-
tions and provides protection against flying particles
both from the FRONT and SIDE should ALWAYS be
worn by the operator and others in the work area
when loading, operating, or servicing this tool. Eye
protection is required to guard against flying fasteners
and debris, which could cause severe eye injury.
m The employer and/or user must ensure that proper
eye protection is worn. We recommend a Wide Vision
Safety Mask for use over eyeglasses or standard safety
glasses that provide protection against flying particles
both from the front and side. Always use eye protection
which is marked to comply with ANS] 287.1.
Additional safety protection will be required in some
environments. For example, the working area may
include exposure to a noise level which can lead to
hearing damage. The employer and user must ensure
that any necessary hearing protection is provided and
used by the operator and others in the work area.
Some environments will require the use of head protec-
tion equipment. When required, the employer and user
must ensure that head protection marked to comply
with ANS! Z89.1 is used.
Stay alert, watch what you are doing, and use com-
mon sense when operating a power tool, Do not
use tool while tired or under the influence of drugs,
alcohol, or medication. À moment of inattention while
operating power tools may result in serious personal
injury.
Dress properly. Do not wear loose clothing or
jewelry. Contain long hair. Keep your hair, clothing,
and gloves away from moving parts. Loose clothes,
jewelry, or long hair can be caught in moving parts.
Do not overreach. Keep proper footing and balance
at all times. Proper footing and balance enables better
control of the tool in unexpected situations.
Use safety equipment. Always wear eye protection.
Dust mask, nonskid safety shoes, hard hat, or hearing
protection must be used for appropriate conditions.
Do not use on a ladder or unstable support. Stable
footing on a solid surface enables better control of the
tool in unexpected situations.
TOOL USE AND CARE
Do not exceed the pressure rating of any compo-
nent in the system.
Protect materiat lines and air lines from damage or
puncture. Keep hose and power cord away from sharp
objects, chemical spills, oil, solvents, and wet floors.
Check hoses for weak or worn condition before
each use, making certain all connections are se-
cure. Do not use if defect is found. Purchase a new
hose or notify an authorized service center for exami-
nation or repair.
Release ail pressures within the system slowly. Dust
and debris may be harmful.
Store idle tools out of the reach of children and
other untrained persons. Tools are dangerous in the
hands of untrained users.
Maintain tools with care. Follow maintenance instruc
tions. Properly maintained tools are easier to control.
Check for misalignment or binding of moving parts,
breakage of parts, and any other condition that
may affect the tools operation. H damaged, have
the tool serviced before using. Many accidents are
caused by poorly maintained tools.
| GENERAL SAFETY RULES
m Never point any tool toward yourseif or others. и
= Keep the exterior of the air compressor dry, clean,
and free from oil and grease. Always use a clean
cloth when cleaning. Never use brake fluids, gasoline,
petroleum-based products, or any strong solvents to
clean the unit. Following this rule will reduce the risk of N
deterioration of the enclosure plastic.
SERVICE
E Tool service must be performed only by qualified
repair personnel, Service or maintenance performed
by unqualified personnel may result in a risk of injury.
Disconnect power supply, open drain valve to de-
compress tank and allow water to drain, and allow
air compressor to hecome cool tao the touch before
servicing. Turn pressure regulator knob fully counter
clockwise after shutting off compressor.
When servicing a tool, use only identical replace-
ment parts. Follow instructions in the Maintenance
section of this manual. Use of unauthorized parts or
failure to follow Maintenance instructions may create a
risk of injury.
SPECIFIC SAFETY RULES
E Know your power tool. Read operator's manual
carefully. Learn its applications and limitations, as weil
as the specific potential hazards related to this tool.
Following this rule will reduce the risk of electric shock,
fire, or serious injury.
Drain tank of moisture after each day's use.
If unit will not be used for a while, it is best to leave
drain valve open until such time as it is to be used. This
will allow moisture to completely drain out and help
prevent corrosion on the inside of tank.
Risk of Fire or Explosion. Do not spray flammable lig-
uid in a confined area. Spray area must be well ventilat-
ed. Do not smoke while spraying or spray where spark
or flame is present. Keep compressors as far from the
spraying area as possible, at least 15 feet from the
spraying area and all explosive vapors.
Risk of Bursting. Do not adjust regulator to result in
output pressure greater than marked maximum pres-
sure of attachment. Do not use at pressure greater than
the rated maximum pressure of this compressor.
If connected to a circuit protected by fuses, use time-
delay fuses with this product.
To reduce the risk of electric shock, do not expose to
rain. Store indoors.
Inspect tank yearly for rust, pin holes, or other im-
perfections that could cause it to become unsafe.
Never weld or drill holes in the air tank,
Make sure the hose is free of obstructions or snags.
Entangled or snarled hoses can cause loss of balance
or footing and may become damaged.
Use the air compressor only for its intended use. Do
not alter or modify the unit from the original design
or function.
Always be aware that misuse and improper handling
of this tool can cause injury to yourself and others,
Never leave a tool unattended with the air hose at-
tached.
Do not operate this tool if it does not contain a feg-
ible warning label.
Do not continue to use a tool or hose that leaks air
or does not function properly.
Always disconnect the air supply and power supply
before making adjustments, servicing a tool, or when a
too! is not in use,
Do not attempt to pull or carry the air compressor
by the hose.
Your tool may require more air consumption than
this air compressor is capable of providing.
E Always follow all safety rules recommended by
the manufacturer of your air tool, in addition to all
safety rules for the air compressor. Following this
rule will reduce the risk of serious personal injury.
Never direct a jet of compressed air toward people
or animals. Take care not to blow dust and dirt
towards yourself or others, Following this rule will
reduce the risk of serious injury.
Protect your lungs. Wear a face or dust mask if the
operation is dusty. Following this rule will reduce the
risk of serious personal injury.
Do not use this air compressor to spray chemicals.
Your lungs can be damaged by inhaling toxic fumes. A
respirator may be necessary in dusty environments or
when spraying paint. Do not carry while painting.
Inspect tool cords and hoses periodically and, if
damaged, have repaired at your nearest Authorized
Service Center. Constantly stay aware of cord loca-
tion. Following this rule will reduce the risk of electric
shock or fire.
Never use an electrical adaptor with this grounded
plug,
Check damaged parts. Before further use of the air
compressor or air tool, a guard or other part that
is damaged should be carefully checked to deter-
mine that it will operate properly and perform its
intended function. Check for alignment of moving
parts, binding of moving parts, hreakage of parts,
mounting, and any other conditions that may affect
its operation. A guard or other part that Is damaged
should be properly repaired or replaced by an au-
thorized service center. Following this rule will reduce
the risk of shock, fire, or serious injury.
Make sure your extension cord is in good condition.
When using an extension cord, be sure to use one
heavy enough to carry the current your product will
draw. A wire gauge size (A.W.G.) of at least 14 is
recommended for an extension cord 80 feet or less
in length. A cord exceeding 100 feet is not recom-
mended. If in doubt, use the next heavier gauge.
The smaller the gauge number, the heavier the
cord, An undersized cord will cause a drop in line voit-
age resulting in loss of power and overheating.
WARNING: This product contains one or more chemicals
known to the State of California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
Save these instructions. Refer to them frequently and
use them to instruct others who may use this air com-
pressor. If you loan someone this tool, loan them these
instructions also.
SYM |
Some of the following symbols may be used an this tool. Please study them and learn their meaning. Proper interpre-
tation of these symbols will allow you to operate the too! better and safer.
SYMBOL NAME DESIGNATION/EXPLANATION
\ Volts Voltage
A Amperes Current
Hz Hertz | Frequency {cycles per second)
\ Alternating Current Type of current
19] Class H Construction Double-insulated construction
Wet Conditions Alert Do not expose to rain or use in damp locations.
| o o , To reduce thé risk of Injury, user must read and understand |
Read The Oper ators Manual operators manual before using this praduct.
e Always wear safety goggles, salety glasses with side shields. or -
Eye Protection a full face shield when operating this product.
Safety Alert Precautions that involve your safety.
| Do not adjust regulator to result in output pressure greater than
Risk of Bursting marked maximum pressure of attachment. Do not use at pres-
sure greater than 155 PSI. | |
1
Risk of Fire or Explosion
Do not spray flammable liquid in a confined area, Spray area
must bs well ventilated. D6 not smoke while spraying or spray
where spark or flame is present, Keep compressors as far from
the spraying area as possible, at least 15 feet from the spraying
area and all explosive vapors.
Risk of Electrical Shock
Hazardous Voltage: Disconnect from power source before ser
vicing, Compressor must be grounded.
Hot Surface
To reduce the risk of injury or damage, avoid contact with any
hot surface.
Risk to hearing
Always wear ear protection when using this tool. Fallure to do
sO may result in hearing toss.
Risk to Breathing
Air obtained directly from the air compressor should never be
used to supply air for human consumption.
SYMBOLS i
The following signal words and meanings are intended to explain the levels of risk associated with this product.
SYMBOL SIGNAL MEANING
Indicates an imminently hazardous situation, which, if not avoided, will
A DANGER: result in death or serious injury.
Indicates a potentially hazardous situation, which, if not avoided, couid
A WARNING: result in death or serious injury.
| Indicates a potentially hazardous situation, which, if not avoided, may
A CAUTION: result in minor or moderate injury.
; (Without Safety Alert Symbol) Indicates a situation that may result in —
CAUTION: property damage.
SERVICE A
Servicing requires extreme care and knowledge and WARNING:
should be performed only by a qualified service tech- To avoid serious personal injury, do not attempt to use
nician. For service we suggest you return the product to this product until you read thoroughly and understand
the nearest AUTHORIZED SERVICE CENTER for repair. completely the operator's manual. Save this operator's
When servicing, use only identical replacement parts. manual and review frequently for continuing safe oper-
ation and instructing others who may use this product.
ÁN WARNING:
The operation of any power tool can result in foreign objects being thrown into your eyes, which can re-
sult in severe eye damage. Before beginning power tool operation, always wear safety goggles, safety
glasses with side shields, or a full face shield when needed. We recommend Wide Vision Safety Mask
for use over eyeglasses or standard safety glasses with side shields. Always use eye protection which
is marked to comply with ANS! 287.1.
SAVE THESE INSTRUCTIONS |
ELECTRICAL
EXTENSION CORDS
Use only 3-wire extension cords that have 3-prong
grounding plugs and 3-pole receptacles that accept the
air compressar's plug. When using the air compressor at
a considerable distance from the power source, use an
extension cord heavy enough to carry the current that the
compressor will draw, An undersized extension cord will
cause a drop in line voltage, resulting in a loss of power
and causing the motor to overheat, Use the chart pro-
vided below to determine the minimum wire size required
in an extension cord, Only round jacketed cords listed by
Underwriter's Laboratories (UL) should be used.
“Ampere rating (on ar compressor data piate]
0-2.0 21-34 3560 51-70 71-120 121-160
Cord Length Wire Size (A.W.G.)
285 16 1 16 16 14 la
50' 16 16 16 14 14 12
100 16 18 14 42 10 m
“Used on 12 gauge - 20 amp circuit.
NOTE: AWG = American Wire Gauge
When working with the air compressor outdoors, use an
extension cord that is designed for outside use, This is
indicated by the letters "WA" on the cord's jacket.
Before using an extension cord, inspect it for loose or
exposed wires and cut or worn insulation.
À WARNING:
Keep the extensión cord clear of the working area.
Position the cord so that it will not get caught on lumber,
tools, or other obstructions while you are working with
a power tool. Failure to do so can result in serious per-
sonat injury.
ÁN WARNING:
Check extension cords before each use. If damaged,
replace immediately. Never use air compressor with a
| damaged cord since touching the damaged area could
cause electrical shock resulting in serious injury.
NOTE: Use longer air hoses instead of long extension
-cords. Your air compressor will run better and last longer.
ELECTRICAL CONNECTION
This air compressor is powered by a precision built
electric motor, it should be connected to a power sup-
ply that is 120 volts, 60 Hz, AC only (normal household
current). Do not operate this tool on direct current (DC).
A substantial voltage drop will cause a loss of power and
the motor will overheat, If the air compressor does not
operate when plugged into an outlet, double check the
power supply.
SPEED AND WIRING
The no-load speed of the electric motor in this air
compressor is approximately 17,500 rpm. This speed is
not constant and decreases under a load or with lower
voltage. For voltage, the wiring in a shop is as important-as
the motors horsepower rating. A line intended only for lights
cannot properly carry a power too! motor, Wire that is heavy
enough for a short distance will be too light for a greater
distance. A line that can support one power too! may not
be able to support two or three tools.
GROUNDING INSTRUCTIONS
in the event of a malfunction or breakdown, grounding
provides a path of least resistance for electric current
to reduce the risk of electric shock. This aif compressor
is equipped with an electric cord having an equipment-
grounding conductor and a grounding plug. The plug
‘must be plugged into a matching outlet that is properly
installed and grounded in accordance With all local codes
and ordinances.
Do not modify the plug provided. If it will not fit the outlet,
have the proper outlet installed by a qualified electrician,
Improper connection of the equipment-grounding con-
ductor can result in a risk of electric shock. The conduc-
tor with insulation having an outer surface that is gresn
with or without yellow stripes is the equipment-grounding
conductor. If repair or replacement of the electric cord or
plug is necessary, do not connect the equipment-ground-
ing conductor to a live terminal.
Check with a gualified electrician or service personnel if
the grounding instructions are not completely understood,
or if in doubt as to whether the tool is properly grounded.
Replace a damaged or worn cord immediately.
This alr compressor is intended for use on a circuit that
has an outlet like the one shown in figure 1. It also has a
grounding pin like the one shown. This product must be
grounded.
Never use an electrical adaptor with this grounded plug.
8
_Q
NM
| a
GROUNDING | Ш
PIN 120V GROUNDED QUTLET
y Fig. 1,
GLOSSARY OF TERMS
Air Filter
Porous element contained within a metal or plastic hous-
ing attached to the compressor cylinder head which
removes impurity from the intake air of the compressor.
Air Tank
Cylindrical component which contains the compressed air.
Check Valve
Device that prevents compressed air from flowing back
from the air tank to the compressor pump.
Cut-In Pressure
The low pressure at which the motor will automatically
restart.
Cut-Off Pressure
The high pressure at which the motor will automatically
shut off.
Electric Motor
Device which provides the rotationai force necessary to
operate the compressor pump.
Manual On/Off Switch
Control which turns the air compressor on or off. The
pressure switch will not automatically start and control the
compressor unigss the manual On/Off Switch is in the ON
(1) position.
NPT (National Pipe Thread)
National Pipe Thread is a U.S. standard for tapered (NPT)
or straight (NPS) threads used to join pipes and fittings.
A thread sealing tape must be used to provide a leak-free
seal on pipe threaded connections.
Pressure Regulator Knob
Regulates the outgoing pressure from the air outlet to the
tool. It is possible to increase or decrease the pressure at
the outlet by adjusting this control knob.
Pressure Switch
Automatically controls the on/off cycling of the compres-
sor. lt stops the compressor when the cut-off pressure in
the tank is reached and starts the compressor when the
air pressure drops below the cut-in pressure,
PSI (Pounds Per Square inch)
Measurement of the pressure exerted by the force of the
air. The actual psi is measured by a pressure gauge on the
compressor.
Pump
Produces the compressed air with a reciprocating piston
contained within the cylinder.
Regulator Pressure Gauge
Displays the current line pressure. Line pressure is adjust-
ed by rotating the pressure regulator knob.
Safety Valve
Prevents air pressure in the air tank from rising over a
predetermined limit.
SCFM (Standard Cubic Feet Per Minute)
A unit of measure of air delivery,
Tank Pressure Gauge
Indicates the pressure in the air tank.
Thermal Overload Switch
Automatically shuts off the compressor if the temperature
of the electric motor exceeds a predetermined limit.
TOOLS NEEDED
The following tools are needed to tighten the thread ends of coil hose to the male and female quick couplers.
Or e
TWO ADJUSTABLE WRENGHES
FEATURES
PRODUCT SPECIFICATIONS
Running HorsepoWwer.........—.. menes 15 HP LUDÍCENON enn nen Free
Air Tank Capacity... men Y GAL GAUGES cose iii ..... 3.0/1.5 in, diameter
Air Pressure... irre eee ore. 195 PSÍ MAX, Input… cree 120 V, 60 Hz, AC only, 12 AMps
Air Delivery... 25 S8CFM @ psi — Net Weight... cone 30 108.
r N
CARRY HANDLE
TANK PRESSURE
MANUAL ON/OFF SWITCH
{ Co “PRESSURE
OUTLET REGULATOR KNOB
PRESSURE
“QUICK
COUPLER
SAFETY VALVE
DRAIN VALVE
RUBBER FOOT,
TIRE CHUCK
COIL HOSE RUBBER BLOW
GUN NOZZLE
TAPERED NOZZLE
1/4" FEMALE ADAPTER |
1/4" NPT MALE ADAPTER
INFLATION NEEDLE
BLOW GUN ADAPTER
SAFETY NOZZLE
N | INFLATION NEEDLE (2)
| i174” MALE QUICK CON (2) QUICK CONNECT
11/4" FEMALE QUICK CONNECT PLUG (2) THREAD SEALING TAPE COUPLER
« A
10
I" al 1
FEATURES
KNOW YOUR AIR COMPRESSOR PRESSURE REGULATOR KNOB
See Figure 2. Use the pressure regulator knob to adjust the amount of
Before attempting to use this product, familiarize yourself air being delivered through the hose.
with all operating features and safety rules.
REGULATOR PRESSURE GAUGE
ACCESSORY KIT The current line pressure is displayed on the regulator
The accessory kit includes a 25” (+ 1) coi! Hose, 1/4 in. pressure gauge. This pressure can be adjusted by rotating
female quick connect plugs, 1/4 in. male quick connect the pressure regulator knob.
plugs, Thread Sealing Tape, Tire chuck, Tire Gauge, Blow
SAFETY VALVE
gun, Osha approved safety nozzle, Inflation needle blow gun
The safety valve is designed to automatically release air if
adapter, 1/4 in. NPT male adapter, 1/4 in. female adapter,
1/4 in. female quick connect coupler, Inflation needles, the air receiver pressure exceeds the preset maximum.
Tapered nozzle, Rubber blow gun nozzle.
TANK PRESSURE GAUGE
OIL-FREE UNIVERSAL MOTOR The tank pressure gauge indicates the pressure of the air
Your air compressor features permanently lubricated in the tank.
bearings.
ASSEMBLY
PACKING LIST
Air Compressor
25 (+17 coil Hose (1)
1/4 in. female quick connect plugs (2)
UNPACKING
This product has been shipped completely assembled.
E Carefully remove the accessories from the box. Make
sure that all items listed in the packing list are included. 1/4 in. male quick connect plugs (2)
wm Inspect the compressor and accessories carefully to make Thread Sealing Tape (1)
sure no breakage or damage occurred during shipping. Tire chuck (1)
№ Do not discard the packing material until you have Tire Gauge (1)
carefully inspected and satisfactorily operated the tool. Blow gun (1)
| Osha approved safety nozzle (1)
Inflation needle blow gun adapter (1)
1/4 in. NPT male adapter (1)
1/4 in. female adapter (1)
1/4 in. female quick connect coupler (1)
Inflation needles (2)
A Tapered nozzle (1)
WARNING: Rubber blow gun nozzie (1)
If any parts are missing do not operate the compressor or
air tools until the missing parts are replaced. Failure to do
so could result in possible serious personal injury.
A WARNING:
Do not attempt to modify this tool or create accesso-
ries not recommended for use with this tool. Any such
alteration or modification is misuse and could result
in a hazardous condition leading to possible serious
personal injury,
Operator's Manual (1)
Replacement Parts List (1)
ATTACHING HOSE
m Attach the supplied quick-connect fitting to hose (note:
wrap threaded ends with supplied thread sealing tape
before securing fittings to hose).
E Push male end of hose into quick coupler already
installed on the compressor.
A WARNING:
Do not attach any tools to the open end of the hose until
start-up has been completed.
BREAKING IN THE PUMP
See figure 3-5
m Check and tighten all bolts, fittings, etc.
E Turn the pressure regulator knob fully clockwise to
open the air flow.
E Place the switch in the OFF (0) position and plug in the
power cord.
m Open the drain valve completely.
E Place the switch in the ON ( 1) and run the air
compressor for 10 minutes to break in pump parts.
m Place the switch in the OFF (0) position.
B Close the drain valve.
12
QUICK COUPLER
Fig. 3
SWITCH
Fig. 4
DRAIN VALVE
Fig. 5
A
LIFTING
LIFTING (fig. 6)
m For lifting the unit use only the red carry handle.
13
Fig. 6
PERSO
Á WARNING:
Do not allow familiarity with tools to make you carsiess.
Remember that a careless fraction of a second is
sufficient to inflict serious injury.
ÁN WARNING:
Always wear safety goggles or safety glasses with side
shields when operating power tools. Failure to do so
could result in objects being thrown into your ayes
resulting in possible serious injury.
CAUTION:
Do not use in an environment that is dusty or otherwise
contaminated. Using the air compressor in this type of
environment may cause damage to the unit.
APPLICATIONS
Air compressors are utilized in a variety of air system ap-
plications. Match hoses, connectors, aif tools, and acces-
sories to the capabilities of the air compressor.
You may use this tool for the purposes listed below:
m Operating air powered tools requiring up to 2.5 SCFM.
E inflating tires, air beds, sports equipment, etc.
USING THE AIR COMPRESSOR
See Figures 7A - 78
Bm Ensure tank drain is closed.
m Turn regulator knob counter clockwise until outlet
pressure is at zero (0).
@ Ensure power switch is in the OFF (0) position and air
compressor is unplugged.
Elf not ready installed, attach hose to compressor as
previously instructed.
wm Attach 1/4 in. NPT male connector fitting to accessory
or tool you intend to use.
m Insert the other and of the male connector to the quick
coupler on the open end of hose
1h warning:
Always ensure the swith is in the OFF (QO) position and
the regulator pressure gauge reads zero before chang-
ing air tools or disconnecting the hose from the air
outlet. Failure to do so could result in possible serious
personal injury.
Tp E
M Connect the power cord to the power supply.
Wm Turn the switch ON (I) and allow tank pressure to build.
OPERATION
14
Г ь
THREAD
HOSE WITH
AIR SEALING i
dip CWE we
4/4 in. NPT
MALE CONNECTOR Fig. 7A
BLOWER | INFLATION |
ATTACHMENT | ACCESSORIES
1/4 In, NPT
MALE CONNECTOR o a
и
$
5
#
£
Y
+
£
$
t
#
1
#
$
3
i
3
i
+
re
HOSE WITH QUICK =)
COUPLER ATTACHED — SEALING | SATEIY NOZZLE
TAPE Fig. 78 J)
ee
m Rotate pressure regulator knob to desired line pres-
sure. Turning the knob clockwise increases air pres-
sure at the outlet; turning countercolockwise reduces air
pressure at the outlet.
# Following all safety precautions in this manual and the
“manufacturer's instructions in the air too! manual, you
may now proceed to use your air-powered tool.
| wannine:
Check the air tool manual to insure the correct air
pressure regulator setting for optimum operation of
your air tools. If you arre using an air too! not originally
included with the air tool kit supplied with this air
compressor, your tool may require more air consumption
than this air compressor is designed to supply.
Always read your air too! owners manual to match the
correct air supply to your air tool to avoid damage
to the tool or risk of personal injury.
| If using an inflation accessory, control the amount of air
flow with the pressure regulator knob. Turning the knob
fully counterclockwise will completely stop the flow of
air.
NOTE: Always use the minimum amount of pressure
necessary for your application. Using a higher pressure
than needed could cause serious injury and may
permanently damage the tool.
E When finished, always drain the tank and unplug the
unit. Never leave the unit plugged in and/or running
unattended.
DRAINING THE TANK
See Figure 8.
To help prevent tank corrosion and keep moisture out
of the air used, the tank of the compressor should be
drained daily.
To drain:
E Holding the handle, tilt the compressor toward the
drain valve so that it's set in a lower position,
B Open the drain valve completely.
№ Keep the compressor tilted until all moisture has
been removed.
B Drain moisture from tank into a suitable container.
NOTE: Condensate is a polluting material and should be
disposed of in compliance with local regulations.
y !f drain valve is clogged, release all air pressure by pulling
the safety valve. Remove and clean valve, then reinstall.
A WARNING:
Unplug the air compressor and release all air from
the tank before servicing. Failure to depressurize tank
before attempting to remove valve may cause serious
personal injury.
M Turn off drain valve until completely closed.
CHECKING THE SAFETY VALVE
See Figure 9.
À DANGER:
Do not attempt to tamper with the safety vaive. Any-
thing loosened from this device could fly up and hit
you. Failure to heed this warning could resuit in death
or serious personal injury.
The safety valve will automatically release air if the air
receiver pressure exceeds the preset maximum. The valve
should be checked before each day of use by pulling the
ring by hand.
E Turn the air compressor on and allow the tank to fill.
The compressor will shut off when the pressure reach-
es the preset maximum,
B Turn the air compressor off.
E Pull the ring on the safety valve to release air for twenty
seconds.
m Release the ring. Air will stop escaping when the ring
is released at approximately 20 psi. Any continued loss
of air after releasing the safety valve ring indicates a
problem with the safety valve. Discontinue use and seek
service before continued use of the air compressor.
15
OPERATION
SAFETY VALVE Fig. 9
Á WARNING:
If air leaks below 20 psi after the ring has been released,
or if the valve is stuck and cannot be actuated by the
ring, Do Not use the air compressor until the safety
valve has been replaced. Use of the air compressor in
this condition could result in serious personal injury.
MAINTENANCE
Inspect the tank yearly for rust, pin holes, or other imper-
A WARNING: fections that could cause it to become unsafe.
When servicing, use only denticat Ausky placement Avoid using solvents when cleaning plastic parts. Most
parts. Use of any other parts may hazard or plastics are susceptible to damage from various types of
cause product damage. commercial solvents and may be damaged by their use.
Use clean cloths to remove dirt, dust, oil, grease, etc.
a o a À WARNING:
ways wear safety goggles or safety glasses with side
Shields during ower tool operation or when blowing Do not at any time let brake fluids, gasoline, petroleum-
dust. If operation is dusty, also wear a dust mask. based products, penetrating oils, etc, come in contact
> with plastic parts. Chemicals can damage, weaken or
destroy plastic which may result in serious personal
A WARNING: injury. Electric tools used on fiberglass material, wall-
hoard, spackling compounds, or plaster are subject
Always release all pressure, disconnect from power sup- to accelerated wear and possible premature failure
ply, and allow unit to cool to the touch before cleaning or because the fiberglass chips and grindings are highly
making repairs on the air compressor. abrasive to bearings, brushes, commutators, etc. Con-
sequently, we do not recommended using this tool for
GENERAL MAINTENANCE | extended work on these types of materials. However, if
Humidity in the air causes condensate to form in the air you work wn hy ese materials, it Is ox remely
tank. This condensate should be drained daily and/or important to clean the toot Using compressed ar
every hour, using the instructions found in Draining the
Tank. LUBRICATION
The safety valve automatically releases air if the air re- All of the bearings in this tool are lubricated with a suffi-
ceiver pressure exceeds the preset maximum. Check the cient amount of high grade lubricant for the life of the unit
safety valve before each use following the instructions under normal operating conditions. Therefore, no further
found in Checking the Safety Valve. lubrication of the bearings is required.
16
TROUBLESHOOTING
| Problem
Possible Cause
Solution
Compressor will not run
Tank has suificient pressure.
No electrical power.
Blown shop/house fuse.
Tripped shop/home breaker.
Thermal overload open.
Loss of power or overheating.
Pressure switch is bad.
Compressor will turn on when tank
pressure drops to cut-in pressure.
Check to be sure unit is plugged in.
Replace shop/house fuse.
Reset shop/home breaker, determine
why problem happened.
First unplugged the compressor and
wait until it becomes cool. After that
compressor can be used
Check for proper use of extension cord.
Replace pressure switch.
Motor hums but cannot run or runs
slowly
Low voltage
Wrong gauge wire or length of exten-
sion cord
Shorted or open motor winding
Defective check valve or unioader
Check with voltmeter
Check for proper gauge wire and
cord length
Take compressor to service center
Take compressor to service center
Fuses blow/circuit breaker trips
repeatedly
Incorrect size fuse, circuit overload
Wrong gauge wire or length of exten-
sion cord
Defective check valve or unloader
Check for proper fuse, use time-
delay fuse, disconnect other electri-
cal appliances from circuit or operate
compressor on its own branch circuit
Check for proper gauge wire and
cord length
Take compressor 10 service center
Thermal overload protector cuts out
repeatedly
Low voltage
Lack of proper ventilation/room tem-
perature too high
Wrong gauge wire or length of exten-
sion cord
Check with voltmeter
Move compressor to well-ventilated
area
Check for proper gauge wire and -
cord length
Air receiver pressure drops when
compressor shuts off
Loose connections (fittings, tubing,
etc.)
Loose drain valve
Check valve leaking
Check all connections with soap and
water solution and tighten
Tighten drain valve
Take compressor to service center
À DANGER:
Do not disassemble check valve
with air in tank — bleed tank.
Excessive moisture in discharge air
Excessive water in air tank
High humidity
Drain tank
Move to area of less humidity; use air
line filter
Compressor runs continuously
Defective pressure switch
Excessive air usage
Take compressor to service center
Decrease air usage, compressor not
large enough for tool's requirement
Compressor vibrates
Loose mounting bolts
Tighten mounting bolts
Air output lower than normal
Broken inlet valves
Connections leaking
Take compressor to service center
Apply thread sealing tape to fitting
and tighten
17
0%
005.
py ema
Te ae hr Tn na
E
105
нее оне zos
—EOT
A
„Эт
"e
“т
amr
ar E mr ALC
EST
DOE “Let
207 ... 970
Ae are ran, pe ве а
но лианы ный у лье
7
#
cts
AB ve
- ETS
| де, с ï с
pt
=
А В
- „и
u.
18
PORTABLE AIR COMPRESSOR PARTS LIST— MODEL NO. 1503TP
The model number will be found on a plate attached to air tank. Always mention the model number in all
correspondence regarding your PORTABLE AIR COMPRESSOR or when ordering replacement parts.
KEY NO.
023
049
103
105
106
107
108
110
112
116
117
127
131
132
133
145
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
PUMP
CODE
9415139
9038409
9038410
9048062
9047061
9047062
9051149
9049115
9412469
9038003
9038408
9270026
9063217
9065681
9414765
9043253
8413268035
9107244
9415926
9101976
9065077
9411120
9412192
9065682
9064009
9142592
9053583
9038414
9053065
9052113
9052111
9107255
9038411
9143271
9038412
9038413
9142241
9416478
DESCRIPTION Q
AIR FILTER... ern,
SHROUD...
RUBBER FOOT...
CHECK VALVE / NON RET. VIV... RE EPP PRPE ES EPP
QUICK COUPLING….…..……...…crrnrrcescerceeresressenrensanversersearersmsnnverenee
DRAIN TAP cients senses ssa seas asters paras server
RILSAN TUBE are EEE |
PRESSURE. SWITCH................memmn e near severe
CORD WITH PLUG ..................men mn ne Ln nen eres
POWER SWITCH covers O ssness
SENDING.PIPE ............rmeeiememer ner ee es
AIR RECEIVER ……..……….…u…rrrcserrseersnmensencensenementenererssiencéesaees messes esneseneensse
SCREW TE 6X20 ..
WASHER 7X15X1 .. NN tee
SCREW HCEI 6X15 WITH WASHER aussen
WIRE 18AWG GREEN... TD
SCREW HC M5X10...
WASHER D5 .. eee reese erst resserre
CORD PRSWIMOTOR aka EEE EEE
LOCK CABLE ................me.ieimeiee nine nes
SCREW PARKER AB 3,9X16..................01i.00r0000 DDD
ELBOW... I
AIR REGULATOR KNOB .. O ene
El E] TD
GAUGE...
GAUGE... Kara ner
SCREW TE 6X16 ..
CONTROL PANEL o.oo sre
SCREW PARKER 4,2X32 .................e..20000000 rr
CORD HOOK (RIGHT) .............. een Dee e Des
CORD HOOK (LEFT) ….……….….…………remcemnenennençennnnnnmnnnnnannannen
SCREW PARKER 4,2X16 ....................—.... 0 eancnvesante
PUMP OL1958B 120V..............—....0i nene reee ess
19
3
">
/
डाउनलोड
बस एक दोस्ताना अनुस्मारक. आप दस्तावेज़ को यहीं देख सकते हैं. लेकिन सबसे महत्वपूर्ण बात, हमारे एआई ने इसे पहले ही पढ़ लिया है. यह जटिल चीजों को सरल शब्दों में समझा सकता है, किसी भी भाषा में आपके सवालों के जवाब दे सकता है और सबसे लंबे या सबसे जटिल दस्तावेजों को भी जल्दी से नेविगेट करने में आपकी मदद कर सकता है.
विज्ञापन