Mastercraft 3-GALLON OIL-FREE air compressor Instruction manual
विज्ञापन
विज्ञापन
3-GALLON OIL-FREE
AIR COMPRESSOR
099-4161-8
TOLL FREE HELPLINE:
1-877-888-3872
FOR SAFE OPERATION, READ AND UNDERSTAND
ALL CONTENTS OF THE INSTRUCTION MANUAL
1
TABLE OF CONTENTS
SPECIFICATIONS..........................................................................................
2
SAFETY GUIDELINES ..................................................................................
3
GLOSSARY OF TERMS.................................................................................
12
ASSEMBLY.....................................................................................................
13
INSTALLATION...............................................................................................
19
OPERATION...................................................................................................
21
MAINTENANCE .............................................................................................
25
TROUBLESHOOTING....................................................................................
26
PART LISTS...................................................................................................
28
LIMITED WARRANTY ....................................................................................
30
SPECIFICATIONS
Motor.................................................................................120V 60Hz, 2.6-amp
Running Horsepower...............................................................................1/3 Hp
Tank Size...............................................................................................3-gallon
25’ recoil, MAX.
Air Delivery.......................................................................1.0 SCFM @ 40 PSI
0.6 SCFM @ 90 PSI
Cut-in Pressure........................................................................................85 PSI
Cut-out Pressure....................................................................................100 PSI
Max. Pressure........................................................................................100 PSI
Power Cord.....................................................................6ft, 3-prong, 18 AWG
Unit Weight ...............................................................................18.69lb (8.5kg)
2
SAFETY GUIDELINES - DEFINITIONS
This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and
PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these symbols.
Indicates an imminently hazardous situation which, if not avoided,
will
result in
death or serious injury
.
hazardous situation which, if not avoided, could result in death or
serious injury.
Indicates a potentially
Indicates a potentially hazardous situation which, if not avoided,
may
result in
minor or moderate injury.
Used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided,
may
result in
property damage.
IMPORTANT SAFETY INSTRUCTIONS
Some dust created by power sanding, sawing, grinding, drilling, and other construction activities contains chemicals known (to the State of California) to cause cancer, birth defects or other reproductive harm. Some example of these chemicals are: lead from lead-based paints crystalline silica from bricks and cement and other masonry products arsenic and chromium from chemically-treated lumber
Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, always wear
MSHA/NIOSH
approved, properly fitting face mask or respirator when using such tools.
When using air tools, basic safety precautions should always be followed to reduce the risk of personal injury.
3
IMPORTANT SAFETY INSTRUCTIONS
Save these instructions
Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment.
HAZARD
WARNING: Risk of explosion or fire
What Could Happen
It is normal for electrical contacts within the motor and pressure switch to spark.
How To Prevent It
Always operate the compressor in a well ventilated area free of combustible
materials, gasoline, or solvent vapors.
If electrical sparks from compressor
come into contact with flammable vapors, they may ignite, causing fire or explosion.
Restricting any of the compressor
ventilation openings will cause serious overheating and could cause fire.
Unattended operation of this product
could result in personal injury or property damage. To reduce the risk of fire, do not allow the compressor to operate unattended.
If spraying flammable materials, locate
compressor at least 20 feet away from
spray area. An additional length of hose may be required.
Store flammable materials in a secure location away from compressor.
Never place objects against or on top
of compressor. Operate compressor in an open area at least 12 inches away
from any wall or obstruction that would restrict the flow of fresh air to the ventilation openings.
Operate compressor in a clean, dry well ventilated area.
Always remain in attendance with the product when it is operating.
Always disconnect electrical power by moving pressure switch lever to the off position and drain tank daily or after each use.
4
HAZARD
WARNING: Risk of Bursting
Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury.
What Could Happen
1.
Failure to properly drain condensed water from tank, causing rust and thinning of the steel tank.
How To Prevent It
Drain tank daily or after each use. If tank develops a leak, replace it immediately with a new tank or replace the entire compressor.
2. Modifications or attempted repairs to the tank.
3.
Unauthorized modifications to the unloader valve, safety valve, or any other components which control tank pressure.
4.
Excessive vibration can weaken the air tank and cause rupture or explosion
ATTACHMENTS & ACCESSORIES:
Exceeding the pressure rating of air
tools, spray guns, air operated accessories, tires, and other inflatables
can cause them to explode or fly apart, and could result in serious injury.
Never drill into, weld, or make any
modifications to the tank or its attachments.
The tank is designed to withstand specific operating pressures. Never make
adjustments or parts substitutions to alter the factory set operating pressures.
For essential control of air pressure, you
must install a pressure regulator and pressure gauge to the air outlet (if not
equipped) of your compressor. Follow the equipment manufacturers recommendation and never exceed the maximum allowable pressure rating of attachments. Never use compressor to
inflate small low pressure objects such as children’s toys, footballs, basketballs, etc.
HAZARD
WARNING: Risk from Flying Objects
WHAT CAN HAPPEN
The compressed air stream can cause
soft tissue damage to exposed skin and
can propel dirt, chips, loose particles, and small objects at high speed, resulting in property damage or personal injury.
5
HOW TO PREVENT IT
Always wear ANSI Z87.1 approved
safety glasses with side shields when using the compressor.
Never point any nozzle or sprayer
toward any part of the body or at other
people or animals.
Always turn the compressor off and
bleed pressure from the air hose and tank before attempting maintenance, attaching tools or accessories.
HAZARD
WARNING: Risk of Electric Shock
WHAT CAN HAPPEN
Your air compressor is powered by
electricity. Like any other electrically powered device, If it is not used properly
it may cause electric shock.
Repairs attempted by unqualified
personnel can result in serious injury or death by electrocution.
HOW TO PREVENT IT
Never operate the compressor outdoors
when it is raining or in wet conditions.
Never operate compressor with
protective covers removed or damaged.
Any electrical wiring or repairs required on this product should be performed by
authorized service center personnel in accordance with national and local electrical codes.
Electrical Grounding: Failure to provide
adequate grounding to this product could result in serious injury or death from electrocution.
See grounding instructions.
Make certain that the electrical circuit
to which the compressor is connected
provides proper electrical grounding, correct voltage and adequate fuse protection.
HAZARD
WARNING: Risk to Breathing
WHAT CAN HAPPEN
The compressed air directly from your compressor is not safe for breathing.
The air stream may contain carbon
monoxide, toxic vapors, or solid
particles from the tank. Breathing these
contaminants can cause serious injury
or death.
Sprayed materials such as paint, paint solvents, paint remover, insecticides, weed killers, may contain harmful vapors
and poisons.
HOW TO PREVENT IT
Air obtained directly from the compressor
should never be used to supply air for
human consumption. In order to use air produced by this compressor for breathing, suitable filters and in-line
safety equipment must be properly
installed. In-line filters and safety
equipment used in conjunction with the compressor must be capable of treating
air to all applicable local and federal codes prior to human consumption.
Work in an area with good cross
ventilation. Read and follow the safety
instructions provided on the label or safety data sheets for the materials you
are spraying. Use a NIOSH/ MSHA
approved respirator designed for use with your specific application.
6
come into contact with you or your clothing.
7
HAZARD
WARNING: RISK OF SERIOUS INJURY OR PROPERTY
DAMAGE WHEN TRANSPORTING COMPRESSOR
(Fire, Inhalation, Damage to Vehicle Surfaces)
WHAT CAN HAPPEN
Oil can leak or spill and could result in fire or breathing hazard; serious injury or death can result. oil leaks will damage carpet, paint or other surfaces in vehicles or trailers.
HOW TO PREVENT IT
Always place COMPRESSOR on a
protective mat when transporting to protect against damage to vehicle from leaks. Remove COMPRESSOR from vehicle immediately upon arrival at your destination.
HAZARD
WARNING:
RISK OF UNSAFE OPERATION
WHAT CAN HAPPEN
Unsafe operation of your air compressor
could lead to serious injury or death to you or others.
HOW TO PREVENT IT
Review and understand all instructions and warnings in this manual.
Become familiar with the operation and
controls of the air compressor.
Keep operating area clear of all persons, pets, and obstacles.
Keep children away from the air compressor at all times.
Do not operate the product when
fatigued or under the influence of alcohol or drugs. Stay alert at all times.
Never defeat the safety features of this product.
Equip area of operation with a fire extinguisher.
Do not operate machine with missing, broken, or unauthorized parts.
8
GENERAL SAFETY RULES
WORK AREA
Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents.
Do not operate power tools in explosive atmospheres, such as in the
presence of flammable liquids, gases, or dust. Power tools create sparks which may ignite the dust or fumes.
Keep bystanders, children, and visitors away while operating a power
tool. Distractions can cause you to lose control. Protect others in the work area from debris such as chips and sparks. Provide barriers or shields as needed.
ELECTRICAL SAFETY
Grounded tools must be plugged into an outlet properly installed and grounded in accordance with all codes and ordinances. Never remove the grounding prong or modify the plug in any way. do not use any adapter plugs. Check with a qualified electrician if you are in doubt as to
whether the outlet is properly grounded. If the tools should electrically malfunction or break down, grounding provides a low resistance path to carry electricity away from the user.
Avoid body contact with grounded surfaces such as pipes, radiators,
ranges, and refrigerators. There is an increased risk of electric shock if your body is grounded.
Do not expose power tools to rain or wet conditions. Water entering a power tool will increase the risk of electric shock.
Do not abuse the Power Cord. Never use the Power Cord to carry the tools or pull the Plug from an outlet. keep the Power Cord away from heat, oil, sharp edges, or moving parts. Replace damaged Power Cords
immediately. Damaged Power Cords increase the risk of electric shock.
When operating a power tool outside, use an outdoor extension cord
marked “W-A” or “W”. These extension cords are rated for outdoor use, and reduce the risk of electric shock.
PERSONAL SAFETY
Stay alert. Watch what you are doing, and use common sense when operating a power tool. Do not use a power tool while tired or under the
influence of drugs, alcohol, or medication. A moment of inattention while operating power tools may result in serious personal injury.
Dress properly. do not wear loose clothing or jewelry. Contain long hair.
Keep your hair, clothing, and gloves away from moving parts. Loose clothes, jewelry, or long hair can be caught in moving parts.
9
GENERAL SAFETY RULES
Avoid accidental starting. be sure the Power Switch is off before
plugging in. Carrying power tools with your finger on the Power Switch, or plugging in power tools with the Power Switch on, invites accidents.
Remove adjusting keys or wrenches before turning the power tool on. A wrench or a key that is left attached to a rotating part of the power tool may result in personal injury.
Do not overreach. Keep proper footing and balance at all times. Proper footing and balance enables better control of the power tool in unexpected situations.
Use safety equipment. Always wear eye protection. Dust mask, nonskid safety shoes, hard hat, or hearing protection must be used for appropriate conditions. Always wear ANSI-approved safety goggles and a dust mask/respirator when using or performing maintenance on this tool.
TOOL USE AND CARE
Use clamps (not included) or other practical ways to secure and support
the work piece to a stable platform. Holding the work by hand or against your body is unstable and may lead to loss of control.
Do not force the tool. Use the correct tool for your application. The correct tool will do the job better and safer at the rate for which it is designed.
Do not force the tool and do not use the tool for a purpose for which it is not intended.
Do not use the power tool if the Power Switch does not turn it on or off.
Any tool that cannot be controlled with the Power Switch is dangerous and must be replaced.
Disconnect the Power Cord Plug from the power source before making
any adjustments, changing accessories, or storing the tool. Such preventive safety measures reduce the risk of starting the tool accidentally.
Store idle tools out of reach of children and other untrained persons.
Tools are dangerous in the hands of untrained users. Keep children away from.
Maintain tools with care. Properly maintained tools are less likely to bind and are easier to control. Do not use a damaged tool. Tag damaged tools “Do not use” until repaired.
Check for misalignment or binding of moving parts, breakage of parts, and any other condition that may affect the tool’s operation. If damaged,
have the tool serviced before using. Many accidents are caused by poorly maintained tools.
Use only accessories that are recommended by the manufacturer for
your model. Accessories that may be suitable for one tool may become hazardous when used on another tool.
SERVICE
Tool service must be performed only by qualified repair personnel.
Service or maintenance performed by unqualified personnel could result in a risk of injury.
10
SPECIFIC SAFETY RULES
Maintain labels and nameplates on the Air Compressor. These carry important information. If unreadable or missing, contact toll free helpline:
1-877-888-3872 for a replacement.
Always wear ANSI-approved safety impact eye goggles and heavy work
gloves when using the Air Compressor. Using personal safety devices reduce the risk for injury. Safety impact eye goggles and heavy work gloves are available from CTC.
Maintain a safe working environment. Keep the work area well lit. Make sure there is adequate surrounding workspace. Always keep the work area free of obstructions, grease, oil, trash, and other debris. Do not use a power tool in areas near flammable chemicals, dusts, and vapors. Do not use this product in a damp or wet location.
Avoid unintentional starting. Make sure you are prepared to begin work before turning on the Air Compressor.
Do not force the Air Compressor. This tool will do the work better and safer at he pressure and capacity for which it was designed.
Always unplug the Air Compressor from its electrical outlet before performing any inspection, maintenance, or cleaning procedures.
Before each use, check all nuts, bolts, and screws for tightness. Vibration may cause these to loosen.
Drain compressor every day. Do not allow moisture to build up inside the compressor.
Make sure all equipment is rated to the appropriate capacity. Adjust the output air pressure to the tool’s operating capacity.
Avoid explosions and fire. Never place flammable objects near the compressor. Never spray water or any flammable liquids towards the compressor.
Avoid bodily injury. Never direct the air outlet at persons or animals.
Never leave the air tool unattended when it is plugged into the air
compressor. Turn off the tool, and unplug it from air compressor outlet before leaving.
WARNING! People with pacemakers should consult their physician(s) before using this product. Electromagnetic fields in close proximity to a heart pacemaker could cause interference to or failure of the pacemaker.
11
GLOSSARY OF TERMS
Become familiar with these terms before operating the unit.
CFM: Cubic feet per minute.
SCFM: Standard cubic feet per minute; a unit of measure of air delivery.
PSI: Pounds per square inch; a unit of measure of pressure.
Code Certification: Products that bear one or more of the following marks:
UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent safety laboratories and meet the applicable Underwriters Laboratories
Standards for Safety.
Cut-In Pressure: While the motor is off, air tank pressure drops as you continue to use your accessory. When the tank pressure drops to a certain low level the motor will restart automatically. The low pressure at which the motor automatically restarts is called "cut-in" pressure.
Cut-Out Pressure: When an air compressor is turned on and begins to run, air pressure in the air tank begins to build.
It builds to a certain high pressure before the motor automatically shuts off - protecting your air tank from pressure higher than its capacity. The high pressure at which the motor shuts off is called "cut-out" pressure.
Branch Circuit: Circuit carrying electricity from electrical panel to outlet.
DUTY CYCLE
Air compressors should be operated on not more than a 50% duty cycle. This means an air compressor that pumps air more than 50% of one hour is considered misuse, because the air compressor is undersized for the required air demand.
Maximum compressor pumping time per hour is 30 minutes.
ACCESSORIES INCLUDED
includes: 2-in-1 brad nailer&stapler, nails, 25’ recoil air hose, inflation needle,
tapered blow, gun nozzle, blow gun adapter, blow gun safety nozzle, blow gun,
tire chuck, 1/4’’ male quick-connect plugs, PTEE- thead seal tape,1/4’’ female quickconnect body, hex wrench(2) and oil.
12
ASSEMBLY
UNPACKING
This product has been shipped completely assembled.
Carefully remove the tool and any accessories from the box. Mark sure that all items
listed in the packing list are included.
Inspect the tool carefully to make sure no breakage or damage occurred during shipping.
Do not discard the packing material until you have carefully inspected and satisfactorily
operated the tool.
If any parts are damaged or missing, please call 1-877-888-3872 for assistance.
PACKING LIST
Air Compressor
Accessories (15)
Operator’s Manual (not shown)
1
Includs:
1 air compressor
2 2-in-1 brad nailer&stapler
3 25' Recoil air hose
4 Inflation Needle
5 Tapered Blow Gun Nozzle
6 Blow Gun Adapter
7 Blow Gun Safety Nozzle
8 Blow Gun
9 Tire Chuck
10 ¼”Male Quick-Connect Plugs
11 PTFE - Thread Seal Tape
12 ¼” Female Quick-Connect Body
13 Nails (100 pcs)
14 oil
15&16 Hex wrench
17 Operator’s Manual (not shown)
2
3
11
14
15
16
13
4
5
6
7
8
9
10
12
13
ASSEMBLY
Make sure the Power Switch of the tool is in its “Off” position and that the tool is unplugged from its electrical outlet, and all air pressure is released before making any adjustments to the tool.
1. Close the Drain Valve under the Tank by turning it clockwise until it stops.
2. Connect the high pressure air hose to the air outlet.
The outlet is 1/4” x 18 NPT. For easy connection or removal, a quick coupler should be installed on the end of the air outlet.
3. To extend the life of most air tools, it is recommended to install an oiler and water filter in series with the air output line of the Air Compressor as shown below.
4. Connect the other end of the high pressure air hose to the air tool.
Do not remove or try to adjust the factory sealed Pressure
Controller; removal can cause the Tank to over pressurize and explode.
(Brad Nailer)
14
ASSEMBLY
Attaching Air Hose To Compressor
1.
2.
Using your left hand push quick connect towards the body of the compressor.
Firmly press fit the male quick connect portion on the air hose into the female quick connect and release female quick connect locking hose in place.
NOTE: When connecting or disconnecting air hose remove air from tank.
15
Fig. A
ASSEMBLY
Assemble Accessories
The unit is supplied with an accessory kit and inflator/deflator kit, choose the accessory needed.
Assemble Accessory Kit
(See Fig. B)
To Assemble Female Tire Chuck
1. Assemble female tire chuck (a) to hose (b) and tighten securely with wrenches.
To Assemble Accessories
1. Attach the blow gun (c) to hose (b).
Risk of unsafe operation. If an accessory is not being used with the blow gun, the safety nozzle MUST be assembled.
2. Assemble the safety nozzle (d) or blow gunadapter (e) to blow gun.
NOTE:To use the inflating needle (f) or the tapered inflator (g), need to use the blow
gun adapter (e) to assembled to the blow gun
3. Attach the inflation needle(f) to the blow gun adapter on the blower gun.
g a e b f c d
Fig. B
16
ASSEMBLY
Assembling Inflation Needle Or Tapered Nozzle
The blow gun (c) and blow gun adapter (e) from the accessory kit is needed to use the inflator/deflator kit. (See Fig. C/Fig. D)
1. Attach the blow gun to hose.
2. Attach blow gun adapter to blow gun.
3. Attach the inflation needle (f), tapered nozzle (g).
Safety Nozzle
g e f c
Fig. C
Fig. D
17
ASSEMBLY
Quick-Connect
(See Fig. E)
1. Assemble the 1/4”male quick-connect plug (k,l) or 1/4” female quick-connect plug to the 1/4” Female quick-connect body.
2. Attach the quick-connect plug to the hose.
j i
PULL k l
Fig. E
NOTE: Always use PTFE tape on all threaded components, to prevent leaks.
18
INSTALLATION
GROUNDING INSTRUCTIONS
This product must be grounded. In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock.
This product is equipped with an electric cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Do not modify the plug provided. If it will not fit the outlet, have the proper outlet installed by a qualified electrician.
WARNING:
Improper installation of the grounding plug is liable to result in a risk of electric shock. When repair or replacement of the cord is required, do not connect the grounding wire to either flat blade terminal. The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire.
Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or if in doubt as to whether the product is properly grounded.
Repair or replace a damaged or worn cord immediately. This product is for use on a nominal 120 V circuit and has a grounding plug similar to the plug illustrated in figure.Only connect the product to an outlet having the same configuration as the plug. Do not use an adapter with this product.
Plug
Grounding pin
3-Prong Plug and Outlet
19
Grounded
Outlets
INSTALLATION
EXTENSION CORDS
Grounded
tools require a three wire extension cord. Double Insulated tools can use either a two or three wire extension cord.
As the distance from the supply outlet increases, you must use a heavier gauge extension cord. Using extension cords with inadequately sized wire causes a serious drop in voltage, resulting in loss of power and possible tool damage.
(See Table A.)
The smaller the gauge number of the wire, the greater the capacity of the cord.
For example, a 14 gauge cord can carry a higher current than a 16 gauge cord.
When using more than one extension cord to make up the total length, make sure each cord contains at least the minimum wire size required.
(See Table
A.)
If you are using one extension cord for more than one tool, add the nameplate amperes and use the sum to determine the required minimum cord size.
If you are using an extension cord outdoors, make sure it is marked with the suffix “W-A” (“W” in Canada) to indicate it is acceptable for outdoor use.
Make sure your extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified electrician before using it.
Protect your extension cords from sharp objects, excessive heat, and damp or wet areas.
TABLE A
**Ampere rating (on product data plate)
0-2.0
2.1-3.4 3.5-5.0 5.1-7.0 7.1-12.0 12.1-16.0
Cord Length Wire Size (A.W.G.)
25'
50'
16
16
16
16
16
16
100' 16 16 14
**Used on 12 gauge - 20 amp circuit.
NOTE:AWG = American Wire Gauge
16
14
12
14
14
10
14
12
—
20
OPERATION
KNOW YOUR AIR COMPRESSOR
READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING
YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference.
Tank Air Pressure
Gauge
Overload Protector
Air Release
Safety Valve
Pressure
Adjustment
Power Switch
Output Air
Pressure
Gauge
Air Outlet
21
OPERATION
OPERATING COMPRESSOR
TURNING COMPRESSOR ON
1. Pull and release the Air Release Safety Valve to verify it does not stick.
2. Plug the power cord into a grounded electrical outlet.
3. Press the Power Switch to the On position.
4. Allow the Tank to fill to 85 PSI before using.
With the Air Compressor turned on, operation is automatic and under the control of the internal Pressure Controller.
PRESSURE ADJUSTMENT
Set the appropriate air pressure output for the air tool being used.
1. Turn the Pressure Adjustment knob to the left to decrease output air pressure, or to the right to incease the output air pressure.
2. Read the air output pressure on the Output Air Pressure Gauge.
USING THE AIR RELEASE SAFETY VALVE
The Air Release Safety Valve is used when tank decompression is needed quickly and efficiently.
1. Press the Power Switch to the Off position.
2. Pull on the Air Release Safety Valve ring to release pressure from the Tank.
3. When all pressure is released, let go of the ring on the Air Release Safety
Valve.
EMPTY AIR AND CONDENSATION
The water Drain Valve is located underneath the Air Tank. It must be used daily to release all trapped moisture through this valve. It will also get rid of any condensation that may cause tank corrosion.
Slightly open the water Drain Valve to blow air and moisture out of the Tank. Opening it all the way may cause it to be blown off.
To help prevent tank corrosion and keep moisture out of the air used, the air tank of the compressor should be drained daily.
1. Turn the air compressor off, as shown in the shut down section of the quick reference label.
2. Pull the ring on the safety valve to release until pressure gauge reads less than 20 psi, as shown in the shut down section of the quick reference label.
3. Release the ring.
4. Rotate drain valves clockwise to open, as shown in the shut down section of the quick reference label.
5. Tilt tank to drain moisture from tank into a suitable container.
NOTE: Condensate is a polluting material and should be disposed of in compliance with local regulations. If drain valve is clogged, release all air pressure, remove and clean valve, then reinstall.
22
OPERATION
IMPORTANT:
Never exceed the maximum or minimum pressure. Pressure that is too low or too high may cause excess noise, wear, and/or misfiring.
When connecting the air supply, keep hands and body away from the discharge area of the nailer.
A filter regulator/oiler is required and should be located on the air line as close to the tool as possible.
Keep the air filter clean. A dirty filter will reduce the air pressure supplied to the tool causing a reduction in power and efficiency.
For better performance, install quick-connectors on your tool and a quick coupler on the air hose.
For the best performance, make sure all connections in the air supply are tightly sealed to prevent air loss.
RESET BUTTON:
This compressor is equipped with a manual reset overload protector which will shut off motor if it becomes overloaded. If overload protector shuts motor OFF frequently, look tor the following causes. Low voltageLack ot proper ventilation/room temperature too high, Wrong gauge wire or length of extension cord To reset the air compressor:
1. Turn the air compressor off.
2. Unplug air compressor and wait until compressor cools down.
3. Plug the air compressor into an approved outlet.
4. Turn the air compressor on.
5. Press the reset button.
2
3
MAINTENANCE
MAINTENANCE OF COMPRESSOR
Make sure the Power Switch of the tool is in its “OFF” position and that the tool is unplugged from its electrical outlet before performing any inspection, maintenance, or cleaning procedures.
1. BEFORE EACH USE, inspect the general condition of the tool. Check for loose screws, misalignment or binding of moving parts, cracked or broken parts, damaged electrical wiring, and any other condition that may affect its safe operation. If abnormal noise or vibration occurs, have the problem corrected before further use. Do not use damaged equipment.
2. Purge the Air Tank daily of all air and condensation to prevent corrosion.
3. Store the Air Compressor in a clean and dry location.
4. Check all air fittings for leaks before using.
2
4
TROUBLESHOOTING
TROUBLESHOOTING OF COMPRESSOR
Problem
Air Compressor will not start
Possi ble Causes
1. Loss of power or overheating
2. No electrical power
3. Blown fuse
4. Breaker open
5. Thermal overload open
6. Pressure switch bad
Tank air pressure does not reach 90 PSI and Air Compressor runs continuously.
Air tool not operating at proper speed.
Air Leaking at Drain Valve.
Air hose has leak.
Air output pressure low.
Proba ble Solutions
1. Check for proper use of extension
cord
2. Plugged in? Check fuse/breaker or
motor overload
3. Replace blown fuse
4. Reset, determining why problem
happened
5. see page 13: reset button operation
6. Replace
Tighten Drain Valve.
Tighten or repair air hose.
Compressor runs continuously
Air hose has leak.
1. Defective pressure switch
2. Excessive air usage
3. Check valve leaking
Adjust Pressure Adjustment knob so Air Output Pressure Gauge reads air tool’s proper operating pressure.
Tighten or repair air hose.
1. Replace switch
2. Decrease air usage; compressor
3. Disassemble check valve assembly,
clean or replace
2
5
PARTS LIST
26
PARTS LIST
18
19
20
15
16
17
7
8
9
10
11
12
13
14
3
4
5
6
Item
1
2
Part No.
3290408
3220552
3410652
3220404
3410452
3630252
3630150
3111352
3410352
3110252
3110152
3220840
3640152
3220475
3410302-1
3410552
3030150
3410329
3420652
3290252
Description
Flat Washer
Screw, M5x25
Handle
Screw, ST4.2x25
Tooling Cover
Overload, Protector
Power Switch
Electric Wire Assembly
Screw, ST4.2x25
Motor-pump Assembly
Circult Board
Screw, M4x8
Power Cord
Screw, ST4.8x15
Wire Clip
Cover, Bottom
Tube
Zip Tie
Seal Ring
Spring
Qty
1
1
18
2
1
1
1
1
1
1
1
1
2
2
1
4
1
1
1
1
25
26
27
28
29
Item
21
22
23
24
36
37
38
39
30
31
32
33
34
35
Part No.
3410152
3420350
3220150
3220250
3390250
3290651
3020152
3020252
3630152-1
3220840
3410350
3290706
3220205
3110752
3330152-1
3290275
3420150
3290750
3220150
Description
Ball
Damping Pad
Screw, M6x15
Screw, M6x25
Copper Tube
Washer
Copper hoop
Copper Connector knob
Pressure Controller
Screw, M4x10
Fan
Flat washer
Screw, M4x10
Pressure Regulator Assembly
Tank, 3G
Drain Valve Assembly
Foot
Flat Washer
Screw, M6x15
Qty
2
2
1
1/2
1
1
6
4
1
1
1
4
1
1
1
1
3
6
3/6
27
WARRANTY
Mastercraft is a superior line of products selected for their workmanship and materials.
These products are designed to meet rigorous quality and performance standards, and are approved by our Quality Assurance laboratory.
This Mastercraft product carries a three (3) year repair warranty against defects in workmanship and materials. At its discretion, Mastercraft Canada agrees to have any defective part(s) repaired or replaced free of charge, within the stated warranty period, when returned by the original purchaser with proof of purchase. This product is not guaranteed wear or breakage due to misuse and/or abuse.
This product is not guaranteed if used for industrial or commercial purposes.
TOLL-FREE HELPLINE: 1-877-888-3872
28
डाउनलोड
विज्ञापन