Schlage AD-400 PIM400-485 Wiring Diagram
Add to My manuals1 Pages
Schlage AD-400 PIM400-485
The Schlage AD-400 PIM400-485 is a powerful and versatile access control device that can be used in a variety of applications. With its ability to support up to sixteen AD400 or WRI400 or WPR400 or WSM400 locks, it is ideal for use in large-scale security systems. Some of the key features of the Schlage AD-400 PIM400-485 include:
- Support for up to sixteen AD400 or WRI400 or WPR400 or WSM400 locks
- RS485 communication
- 12/24VDC power supply
- Easy installation
The Schlage AD-400 PIM400-485 is a
advertisement
◉
Touch to zoom
RS485 4000' MAX BELDEN 3106A GALAXY 600/635 CONTROLLER < Im y O <— 10' MAX DROP BELDEN 3106A K— 10' MAX DROP BELDEN 3106A : 120 2x18 [12/24VDC L > ТИ 1 on 120 PIM400-485 | Power | ~ VAC > POWER |? vac X SUPPLY = SUPPLY — Y =” Ш © — s 2x18 2 о a= 8) [] \ ELECTRIC L 120VAC AD300 HINGE AD400 LOCK LOCK GALAXY 600/635 DSI MODULE A SHIELD | | BELDEN 3106A + < WHT/ORG ——] < ORG/WHT т < BLU/WHT END R- R+ AD300 LOCK BELDEN 3106A | ———] — — PIM400-485 | Г — ELECTRIC —] | | HINGE || | | — J2 J5 | GND | | — == TB+ = | | | | J1 RB+ GND | || H TA- = | | L _ o RA- R+ | | + GND J8 J7 J10 J11 ~— | REMOVE SHORTING - NEU | 120 A a HO — | — | BLOCKS ON RS485 | UL 294 LINE | VAC \ | | MODULE | 12/24VDC \ + GND LA SUPPLY \ | UL294 [Neu (420 — a \ 12/24VDC [Une [ VAC INSTALL J19 AND J20 SUPPLY — SHORTING JUMPERS NOTES: 1> ALL LOW VOLTAGE WIRING TO BE STANDARD, MULTI-CONDUCTOR COLOR CODED WITHOUT SPLICES. 2> WIRING TO CONFORM TO APPLICABLE NATIONAL, STATE AND LOCAL ELECTRICAL CODES. 3> REFER TO SPECIFIC PRODUCT INSTALLATION INSTRUCTIONS FOR SPESCIFIC WIRING REQUIREMENTS, 42 THIS DRAWING IS FOR GRAPHICAL REPRESENTATION OF PRODUCTS DETAILED IN THE HARDWARE SET ONLY. 5) x CONDUCTOR COUNT TO BE DETERMINED BY ACCESS CONTROL PANEL PROVIDER, EARTH GROUND SHIELD ON BELDEN 3106A CABLE AT GALAXY 600/635 CONTROLLER ENCLOSURE ONLY. WIRING SHOWN REFLECTS WIRING TO SCHLAGE PIM-485 AND AD-300 FROM GALAXY 600/635 ONLY. ADDITIONAL WIRING WILL BE REQUIRED ON THE GALAXY 600/635 AND WILL NOT BE SHOWN HERE. RS485 TERMINATION IS NOT TYPICALLY REQUIRED. IF YOU ARE EXPERIENCING INTERMITTENT OR ERRATIC COMMUNICATION PROBLEMS, INSTALL A 120 ohm RESISTOR AT THE BEGINNING AND AT THE END OF THE RS485 DATA LINE PARALLELED ACROSS DATA LINES. NOTE, INCORRECTLY INSTALLED TERMINATION RESISTORS CAN CREATE MORE PROBLEMS AND SHOULD ONLY BE USED OF REQUIRED. WITH HHD SET LO AND HI WAPM ID'S. BY DEFAULT, PIM USES 0-15, MUST BE CHANGED TO 1-16. IF LO IS 0 THEY WILL NOT COMMUNICATE. UL 294 POWER SUPPLIES USED SHOULD NOT BOND EARTH GROUND TO SIGNAL GROUND. IF PLENUM RATED CABLE IS REQUIRED USE BELDEN 82842 OR EQUIVALENT. A PIM400-485 WILL SUPPORT UP TO SIXTEEN AD400 OR WRI400 OR WPR400 OR WSM400 TOTAL. NOTE: CONFIGURATION HAS BEEN TESTED IN IALLEGION LABS AND HAS BEEN REVIEWED AND APPROVED BY GALAXY. OPERATION! MAX SIXTY-FOUR AD400/AD300 PER GALAXY 600/635 CPU. EACH DSI BOARD HAS TWO RS485 PORTS EACH SUPPORTING UP TO SIXTEEN AD LOCKS EACH. _ AB ALLEGION &% TITLE: GALAXY 600/635 CONTROLLER PIM400-485 WITH AD400/AD300 LOCK 105337 DATE DRAWN: 09-23-11 REVISION DATE: [1-01-13 APPROVED BY DAN GRAMLICH 07-23-13 DWG NO: REV 823112-6 GALAXY DRAWN/CHECKED BY: BRENDA DOVE 08/23/11 copyright 2013
advertisement