![](http://s3.manualzz.com/store/data/034271560_1-68a1df805bc371d764177d8e7001fd3b-128x128.png)
advertisement
![Pressure Calibration Equipment | Manualzz Pressure Calibration Equipment | Manualzz](http://s3.manualzz.com/store/data/034271560_1-68a1df805bc371d764177d8e7001fd3b-360x466.png)
n sstttrrru m e n nfffo @ o u o u
Precision under pressure
Pressure Calibration Equipment
Catalog 2016
Look us up on www.additel.com or call today (1)714-998-6899
1
ADDITEL CORPORATION
Additel Corporation is one of the leading worldwide providers of pressure calibration tools.
We are dedicated to designing, manufacturing, and delivering the highest quality test tools and portable calibrators for the process and calibration industries. For many years Additel has successfully developed pressure controlers, automated pressure calibrators, digital pressure test gauges, digital pressure calibrators, pressure test and calibration pumps, and multifunction process calibrators. Additel products are currently used in over 70 countries worldwide.
Product quality and customer service along with innovative engineering have been our top priorities and will continue to be our guiding principles going forward. We are committed to customer satisfaction through quality products, competitive pricing, unmatched services/ technical support and continued introduction of new and innovative products.
Phone: 714-998-6899 Fax: 714-998-6999 Email: [email protected]
Corporate Headquarters
Additel Corporation
2900 Saturn Street #B
Brea, CA 92821, USA
European Office
Additel Corporation
Holkebjerhvej 79
5250 Odense, Denmark
Salt Lake City Office
Additel Corporation
1314 West State Rd Suite 101
Pleasant Grove, UT 84062, USA
Asia Office
Additel Corporation
Bldg 5th, No. 3 Fengxiu Middle Road,
Haidian, Beijing, 100094, China
TABLE OF CONTENTS
Pressure Controllers
Additel 780 Series Pressure Controller....................................................01
Automated Pressure Calibrators
Automated Pressure Calibrators Selection Guide ................................... 08
Additel 761 Automated Pressure Calibrators...........................................09
Digital Pressure Calibrators / Gauges
Additel Digital Pressure Gauges Selection Guide ....................................14
Additel 672 Digital Pressure Calibrators.................................................. 16
Application notes......................................................................................19
Additel 681 Digital Pressure Gauges........................................................21
Additel 680 Digital Pressure Gauges........................................................24
Application notes......................................................................................26
Multifunction Process Calibrators
Multifunction Process Calibrators Selection Guide ...................................28
Additel 209 210 Series Loop Calibrator....................................................29
Additel 220 Multifunction Loop Calibrator.................................................31
Additel 221A 222A 223A Multifiction Documenting Process Calibrators..33
Digital Pressure Modules
Additel 160A Series Intelligent Digital Pressure Modules........................36
Pressure Test/Calibration Pumps
Pressure Test/Calibration Pumps Selection Guide ................................. 39
Additel 901 Low Pressure Test Pump..................................................... 40
Additel 912 Low Pressure Test Pump..................................................... 41
Additel 914 Handheld Pneumatic Pressure Test Pump.......................... 42
Additel 916 Pneumatic Pressure Test Pump........................................... 43
Additel 917 Pneumatic Pressure Test Pump........................................... 44
Additel 918 Pneumatic Pressure Test Pump........................................... 45
Additel 919A Pneumatic High Pressure Test Pump................................ 46
Application notes..................................................................................... 47
Additel 920 Pneumatic High Pressure Test Pump.................................. 48
Additel 925 Handheld Hydraulic Pressure Test Pump............................ 49
Application notes..................................................................................... 50
Additel 927 Hydraulic Pressure Test Pump............................................. 51
Additel 928 Hydraulic Pressure Test Pump............................................. 52
Additel 936 Hydraulic High Pressure Calibration Pump.......................... 53
Additel 937 Hydraulic High Pressure Calibration Pump.......................... 54
Additel 938 Hydraulic High Pressure Calibration Pump.......................... 55
Additel 946 Hydraulic High Pressure Calibration Pump...........................56
TABLE OF CONTENTS
Additel 949 Hydraulic Ultra-high Pressure Test Pump.............................57
Additel 959 Hydraulic Ultra-high Pressure Test Pump.............................58
Pressure Manifolds
....................................................................................59
Filters
.........................................................................................................60
Hoses, Adapters and Fittings
....................................................................61
Software
.................................................................................................... 64
Additel 780 Series Pressure Controller
Pressure ranges from vacuum to 3,000 psi (200 bar)
Removable interchangeable intelligent sensors
Precision accuracy of 0.005% of reading plus 0.005% of full scale
Standalone solution to 3,000 psi (200 bar), no gas bottle required when used with the Electric Pump and 3K Gas Booster
Standalone solution to 1,000 psi (70 bar), no gas bottle required when used with the Electric Pump
Standard model accuracy of 0.02% of full scale
External pressure modules to 3,000 psi (200 bar)
WiFi enabled communications
Fully temperature compensated accuracy over 0°C to 50°C
HART Communication and Profibus PA
Large 7” color touch screen display
Control stability of 0.003%FS
Built-in barometer
Easy-to-use icon based user interface
OVERVIEW
For years, we’ve provided the most durable, accurate, quality pressure calibration products for field applications. The Additel 780 series controller incorporates the same durability, accuracy, and quality into a new bench top controller packed with features and functionality that is remarkably easy to use. The Additel 780 series offers two base ranges: to 1,000 psi (70 bar) and to 3,000 psi (200 bar). The base range establishes the maximum controlling range of the controller. Each configuration includes a control sensor which is preselected to the sensor range best suited for your application. External and internal sensors can be used which allows for expanded range and accuracy capability in the future.
There are also two controller types that can be selected: the Additel 780S is the standard controller option without any measurement capability. The Additel 780 has expanded functionality including electrical measurement and HART and Profibus PA communication.
Look us up on www.additel.com or call today (1)714-998-6899
01
MODULAR DESIGN
Each unit comes with one Intelligent Pressure Module configured to the many range offerings provided. Standard accuracy sensors (ADT160A-CPXXX) are silicone pressure sensors with a 1 year accuracy of 0.02% FS. The precision quartz based sensors improve the 1 year accuracy specification to 0.005% of reading + 0.005% FS. Each sensor has been specially aged, tested and screened before assembly. After assembly each sensor is temperature compensated over the range of 0°C to 50°C. The Additel 780 series allows for one internal pressure sensor and one external pressure sensor. The modular design of this unit provides for interchangeability of both the internal and external sensors with other
Intelligent Pressure Modules.
In addition to the Intelligent Pressure Modules, the Additel 780 series has a built in barometric sensor. This allows for switching between gauge pressures to absolute pressures.
STANDALONE SOLUTION
Typical pressure controllers will require a nitrogen bottle for the gas supply which make it difficult to move the controller around without having to move or connect to another bottle.
The Additel 780 series is unique in that with the optional electric pump, you can generate pressures to 1,000 psi (70 bar) without the need of a gas bottle. Add the booster to the configuration and 3,000 psi (200 bar) is achievable with the Additel 780 controller series.
PROCESS FUNCTIONALITY (excl ADT780S versions)
The 780 Series Pressure Controller is considered to handle a very wide range of applications which may normally require a pressure calibrator. Built-in capability, includes current and voltage measurement capability, 24 volt loop power, HART
® switch measurement capability, and much more.
and Profibus PA communication,
MEASUREMENT SPECIFICATIONS
Specification
Pressure range
Control stability
Precision
(includes 1 year stability)
ADT780-1K
-14.5 to 1,000 psi (-0.95 to 70 bar)
0.003% FS (stability based on % FS of control sensor range)
See pressure range table
ADT780-3K
-14.5 to 3,000 psi (-0.95 to 200 bar)
[1]
1 Year stability
0.01% FS standard accuracy sensors
0.005% FS precision accuracy sensors
Media
Over-range indication
Resolution
Pressure type
Clean gas
103% to 120% (based on sensor)
4, 5, 6, or 7 digits (user selectable)
[2]
Gauge, Absolute
Warm up time
15 minutes
Typical pressure settling time
(within 0.003%FS)
20 seconds (10%FS pressure change assuming 50 mL test volume)
Measurement units
Pa, hPa, kPa, MPa, bar, mbar, psi, mmHg@0°C,cmHg@0°C, mHg@0°C, inHg@0°C, inH mH
2
2
O@4°C, mmH
O@20°C, kg/m
2
2
O@4°C, cmH
2
, kg/cm
2
O@4°C, mH
2
O@4°C, mmH
, mtorr, torr, atm, lb/ft
2
2
O@20°C, cmH
, tsi, user selectable
2
O@20°C,
Minimum control pressure
[3]
0.0001 psi 0.001 psi
[1] Gas booster or HP gas supply required to reach 3,000 psi (200 bar). Booster ordered separately.
[2] 7 digit resolution for precision model only.
[3] Dependent on pressure module.
02
Look us up on www.additel.com or call today (1)714-998-6899
BAROMETRIC MEASUREMENT SPECIFICATION
Sensor/Mode
ADT160-02-CPXX
Gauge
N/A
Absolute
40 Pa
[1]
ADT160-01-APXXQ 3 Pa
[2]
N/A
Barometer range (60~110)kPa, the accuracy is 40 Pa (11 Pa is optional)
[1] 40 Pa uncertainty (k=2) includes calibration uncertainty, linearity, and long term stability (<30 Pa per year). Barometer range of 60 to 120 kPa.
[2] Combined linearity, hysteresis, and repeatability. Add 3 Pa when used in gauge mode. When using the ADT160-01-APXXQ sensors with the
ADT780 controller in gauge mode, regular zeroing will realign the barometric reading to provide the most accurate result.
ELECTRICAL MEASURE SPECIFICATIONS
[1]
Specification Range Resolution Accuracy
-30 to 30 V 0.1 mV ±0.01% rdg + 1.5 mV
Volts DC
Current DC
-300 to 300 mV
-30 to 30 mA
1 μV
0.1 μA
±0.01% rdg + 15 μV
±0.01% rdg + 1.5 μA
Switch test
If the switch has detected voltage, the range is from 3 – 24 V
DC 24V output
[1] Not available in ADT780S versions
24V ± 0.24V, max 30 mA
PHYSICAL SPECIFICATIONS
Specification
Power
Pressure ports
Storage temperature
ADT780-1K & ADT780-3K
100 to 240V, 50/60 Hz
G1/8 F
-20°C to 70°C
Operating environment
0-90% RH non-condensing
Display
Weight
7 inch (17.8 cm) color, touch screen display
33 lbs (15 kg)
Dimensions (DWH)
Mounting
16.5 x 17.3 x 5.2 inch (419 x 440 x 132 mm)
Standard desktop, optional rack mount kit
Shock
Vibration
4G
1G 10Hz~500Hz
OTHER SPECIFICATIONS
WiFi specifications
Vent
Communications
Stability indicator
Typical slew rate
Operating modes
Display modes
Localization
Conformity
802.11 b, g, and n
Front panel vent and safety release button (only for 780S)
RS232,USB,LAN,WIFI
User selectable
Typically 20 seconds
Control, measure, and vent
Controller – show pressure indication and control
Calibrator – shows pressure indication, control, and electrical measurement (excl ADT780S)
English, Chinese (simplified), German, Spanish, French, Italian, Portuguese, Russian, Japanese
CE
Calibration certification
NIST-traceable certificate of calibration with data included
Warranty
1 year
Look us up on www.additel.com or call today (1)714-998-6899
03
STANDARD ACCESSORIES
ADT127-X External
Manifold
1 pc
Manifold connection cable
1 pc
Power adapter
1 pc
OPTIONAL ACCESSORIES
ADT160A
Pressure modules (see module information)
ADT121-X
External pneumatic pressure manifold, 3,000 psi (200 bar), four hand-tight quick connectors
ADT780-3K-BST
3,000 psi (200 bar) gas booster
9022 Test leads
2 sets (4 pc)
ADT780-1K-EPUMP
1,000 psi (70 bar) electrical pump
9020 Short circuit cable
1 set (2 pc)
ADT780-VACPUMP
Vacuum pump
9060 Pressure module connection cable
1 pc
9050
RS232 to USB adapter
Adapter set (adapters to fit the ADT78X port to male fittings)
1 set
(2 pcs G1/8M to G1/4M, 2 pcs
G1/8M to Festo, release valve)
CD Manual
NIST traceable certificate
O-rings
Vacuum/Vent tubing
1 pc
1 pc
3 types
2 pc
ADT100-FLT-600
Liquid trap
9912-780
Shipment case for the ADT780
Controller
9506 Additel/PCal
Manual calibration software
9530 Additel/ACal
Automated calibration software,
Task and asset management
9245-780
ADT100-780-Kit
Rack mount kit
Adapter set, total 9 pcs.
G1/8 M to 1/4NPT M (3 pcs)
G1/8 M to G1/4 M (3 pcs)
G1/8 M to M20x1.5 M (3 pcs)
ADT780 ORDERING INFORMATION
(Controller without 3K psi booster)
Model Number
ADT780 3k CP300 N HABP
04
Model 780
Model 780S
Maxmum Range:
3K-3,000 psi (200 bar)
1K-1,000 psi (70 bar)
Pressure range:
See range table
Look us up on www.additel.com or call today (1)714-998-6899
High Accuracy Barometer
Manifold port type:
N-1/4NPT male
N2-1/2NPT male
B-1/4BSP male
B2-1/2BSP male
M-M20x1.5 male
ADT160A Intelligent Digital Pressure Modules
Gauge pressure Differential pressure
SPECIFICATIONS
Pressure Range
P/N psia
Precision Quartz Sensors
[1] bar.a
Media Accuracy
Pressure Rating
Burst Over Pressure
Suggested
Controller
Compatibility
Internal/
External
Use
AP45Q
AP100Q
AP400Q
AP500Q
AP1KQ
AP2KQ
AP3KQ
0 to 45
0 to 100
0 to 400
0 to 500
0 to 1,000
0 to 2,000
0 to 3,000
Standard Pressure Sensors
3.0
7.0
28
35
70
140
200
G
G
G
G
G
G
G
0.005% rdg + 0.005% FS
0.005% rdg + 0.005% FS
0.005% rdg + 0.005% FS
0.005% rdg + 0.005% FS
0.005% rdg + 0.005% FS
0.005% rdg + 0.005% FS
0.005% rdg + 0.005% FS
3x
3x
3x
3x
3x
3x
3x
1.2x
1.2x
1.2x
1.03x
1.1x
1.1x
1.1x
ADT780-1K only
ADT780-1K only
Both
Both
Both
ADT780-3K only
ADT780-3K only
Both
Both
Both
Both
Both
Both
Both
P/N
Pressure Range psig bar.g
Media Accuracy
Pressure Rating
Burst Over Pressure
Suggested
Controller
Compatibility
ADT780-1K only
Internal/
External
Use
Both
CP10
CP15
±10
±15
±0.7
±1.0
G
G
0.02% FS
0.02% FS
3x
3x
1.2x
1.2x
ADT780-1K only Both
CP30
CP50
-15 to 30
-15 to 50
-1 to 2.0
-1 to 3.5
G
G
0.02% FS
0.02% FS
3x
3x
1.2x
1.2x
ADT780-1K only
ADT780-1K only
Both
Both
CP100
CP300
-15 to 100
-15 to 300
-1 to 7.0
-1 to 20
G,L
G,L
0.02% FS
0.02% FS
3x
3x
1.2x
1.2x
ADT780-1K only
Both
Both
Both
CP500
CP600
-15 to 500
-15 to 600
-1 to 35
-1 to 40
G,L
G,L
0.02% FS
0.02% FS
3x
3x
1.2x
1.2x
Both
Both
Both
Both
CP1K
CP2K
-15 to 1,000
-15 to 2000
-1 to 70
-1 to 140
G,L
G,L
0.02% FS
0.02% FS
3x
3x
1.2x
1.2x
Both
ADT780-3K only
Both
Both
CP3K
CP5K
-15 to 3,000
-15 to 5000
-1 to 200
-1 to 350
G,L
G,L
0.02% FS
0.02% FS
3x
3x
1.2x
1.2x
ADT780-3K only
N/A
Both
External
CP10K
-15 to 10,000 -1 to 700 G,L 0.02% FS 2x 1.2x
N/A External
[1] Contact Additel for other range options.
**Low pressure sensors (ADT160A-XX-DPX) available for low pressure and differential pressure measurement. Also available for low pressure control (gauge mode only). Ranges from ±1 inH
2
0 (2.5 mbar) to 300 inH
2
O (700 mbar).
Look us up on www.additel.com or call today (1)714-998-6899
05
SENSOR SPECIFICATIONS
Standard Accuracy
CPXXX AP3KQ AP1KQ
Precision Accuracy
AP100Q
Temperature compensation
Operating temperature
-10°C to 50°C (14°F to 122°F)
-10°C to 50°C (14°F to 122°F)
0°C to 50°C (32°F to 122°F)
0°C to 50°C (32°F to 122°F)
Storage temperature
-20°C to 70°C (-4°F to 158°F) -20°C to 70°C (-4°F to 158°F)
Relative humidity
Pressure connections
(for external use only)
Enclosure
(for external use only)
Dimensions (Dia x H)
95% RH
1/4NPT, 1/4BSP, 1/2BSP, M20x15
SS enclosure
95% RH
1/4NPT, 1/4BSP, 1/2BSP, M20x15
33 mm x 123 mm (1.3” x 4.84”) 44 mm x 220mm (1.7” x 8.7”)
Weight
0.4 kg (0.99 lb)
[1] Internal sensors used to go inside the ADT780 need to have a M20 connection and connection kit.
0.8 kg (1.8 lb)
SS enclosure
60 mm x 190 mm (2.4” x7.5”)
1.2 kg (2.6 lb)
ORDERING INFORMATION
Model Number
ADT160A 01 CP300 PSI N
Model
Range type:
PSI - range by psi
BAR - range by bar
Accuracy:
01 – 0.005% rdg + 0.005% FS
02 – 0.02% FS
Pressure range:
See range table
External pressure port type:
N - 1/4NPT male
N2 - 1/2NPT male
B - 1/4BSP male
B2 - 1/2BSP male
M - M20x1.5 male
06
Look us up on www.additel.com or call today (1)714-998-6899
Electric Pump and Booster
Additel 780-1K-EPUMP
ELECTRIC PUMP
Generates Vacuum to 1,000 psi (70 bar)
Built-in filter and liquid trap
1,000 psi (70 bar) Electric Pump Specifications
Pressure range
-13.5 to 1,080 psi (-0.95 to 75 bar)
Weight
Size(WHD)
69.6 lbs (31.6 kg)
17.3 X 9.3 X 21.7 inch (440 X 235X 550 mm)
Power
Media
100 to 240V
Air
Outlet port
Storage temperature
G1/8F
-20°C to 70°C
Operating environment
0-90% RH non-condensing
Mounting
Standard desktop, optional rack mount
Control operation
2 LED displays with pressure limit settings
Typical max pressure time
Approx 2 min with ADT780 Controller
Additel 780-3K-BST
BOOSTER
3,000 psi (200 bar) Gas Booster Specifications
Minimum inlet pressure
300 psi (20 bar)
Out pressure range
300 to 3,600 psi (250 bar)
Inlet flow rate
Size (WHD)
500ml/min
17.8 X 7.3 X 23.9 inch (451 X 185 X 607 mm)
Weight
Power
74 lbs (33.6 kg)
100 to 240V
Supply media
Nitrogen or clean gas
Look us up on www.additel.com or call today (1)714-998-6899
07
Additel 761
Automated Pressure Calibrators
Selection Guide
Model
Features
Pressure
Range
761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP
-25 to 25 mbar
(-10 to 10 inH
2
O)
-0.95 to 1 bar
(-13.5 to 15 psi)
-0.95 to 7 bar
(-13.5 to 100 psi)
0.05 to 8 bar.a
(1.2 to 115 psi.a)
-0.90 to 25 bar
(-13 to 375 psi)
0.1 to 26 bar.a
(1.7 to 390 psi.a)
-0.90 to 40 bar
(-13 to 600 psi)
0.1 to 41 bar.a
(1.7 to 615 psi.a)
100 to
1200 hPa
Pressure
Module 1
-2.5 to 2.5 mbar
(-1 to 1 inH
2
O)
-25 to 25 mbar
(-10 to 10 inH
2
O)
-0.95 to 2.5 bar
(-13.5 to 35 psi)
0.05 to 3.5 bar.a
(1.2 to 50 psi.a)
-0.9 to 2.5 bar
(-13 to 35 psi)
0.1 to 3.5 bar.a
(1.7 to 50 psi.a)
-0.9 to 2.5 bar
(-13 to 35 psi)
0.1 to 3.5 bar.a
(1.7 to 50 psi.a)
100 to
1200 hPa
Pressure
Module 2
Differential
Pressure
Gauge Pressure
Absolute
Pressure
Barometric
Pressure
Temperature
Compensated
Built-in Electrial
Pump
-25 to 25 mbar
(-10 to 10 inH
2
O)
-0.95 to 1 bar
(-13.5 to 15 psi)
•
•
•
•
Built-in Filter
Built-in Liquid
Trap
Source 0 to
22mA
Measure mA
or V
Measure external pressure module
24V Loop power
Pressure switch test
HART
Communication
Documenting
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0 to 7 bar
(0 to 100 psi)
•
0.05 to 8 bar.a
(1.2 to 115 psi.a)
0 to 25 bar
(0 to 375 psi)
0.1 to 26 bar.a
(1.7 to 390 psi.a)
0 to 40 bar
(0 to 600 psi)
0.1 to 41 bar.a
(1.7 to 615 psi.a)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
NA
•
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
08
Look us up on www.additel.com or call today (1)714-998-6899
Additel 761
Automated Pressure Calibrators
Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inH
2
O)
0.02%FS accuracy
Dual pressure modules
Built-in filter and liquid trap with venting system prevents contamination of the calibrator
Portable (12.4 lb)
OVERVIEW
With a built-in high performance electronic pump and precision pressure controller, the 761 series portable automated pressure calibrators provide a turnkey solution for calibration of gauges, transmitters, and switches both in the field and in the laboratory.
In a portable package, this calibrator can automatically generate pressures from 90% vacuum to 600 psi (40 bar) with 0.005% FS pressure control stability and 0.02% FS accuracy. To improve the calibrator accuracy, two pressure modules with differing ranges are built-in and integrated with the internal pump and controller.
The 761-LLP is specially designed for low pressure calibration, and pressures can be set to as low as 0.01 Pa (0.00004 inH
(0.0002 inH
2
O).
2
O) with a control stability better than 0.05 Pa
The 761-BP is designed for barometric gauge calibration. With a quartz pressure sensor, the accuracy of 761-BP can achieve 0.01%FS accuracy.
With optional external pressure modules (160A series), the 761 can measure pressures up to 10,000 psi (700 bar) with 0.02%FS accuracy. In addition to the pressure generation, control, and measurement capabilities, the 761 also features
HART communication capability, supplies 24V loop power, and reads the current or voltage produced by the pressure transducers. The 761 is a state of the art automated pressure calibrator which brings automated pressure calibration to the field.
Look us up on www.additel.com or call today (1)714-998-6899
09
FEATURES
Pressure Range
Pressure generated by built-in pump and controlled automatically from 90% vacuum to 600 psi (40 bar)
Pressure measured with external pressure modules
(160A series) to 10,000 psi (700 bar)
Accuracy (Fully temperature compensated)
0.02%FS
0.05%FS (ADT761-LLP)
0.01%FS (ADT761-BP)
Control Stability
<0.005%FS
ADT761-LLP: < 0.05 Pa (0.0002 inH
2
O)
Contamination prevention system
Built-in filter and liquid trap with venting system prevent contamination of the calibrator
Solid particles can be blocked by built-in filter
A small amount of liquid can be collected by the builtin liquid trap
Both solid particles and liquid can be blown out through the venting system
Automation and Test Program
Fully Automated pressure calibration
Task preset and auto run
Auto step
Easy to Use
User friendly interface
Intuitive icon driven menu structure
Sourcing and Measuring electrical signals
Measure mA with 0.01% RD + 1.5μA accuracy
Measure V with 0.01% RD + 1.5mV accuracy
Source/sink 0 to 22mA current
24 VDC loop power supplied to pressure transmitter during test
Automated switch test
Misuse Protection
Up to 30V misuse protection on any two sockets
Display
7" LCD color screen (800X480)
Documenting and on-demand logging
Task management capability
Internal memory stores 200 tasks
Download tasks and upload results
900 snapshots
HART Communication capability
Support HART instrumentation
Pressure output rate
2.4 liters/minute
Rechargeable battery:
Rechargeable battery with up to 8 hours operation between charges
Leak testing:
Apply leak test to an external pressure system to determine the magnitude of pressure variations due to leaks
Pipeline Protection: Special design the pipeline layout to avoid possible blockage and leakage
Portable: Only 12.4 lb
Multi Lingual Interface
English, German, French, Italian, Spanish, Portuguese,
Simplified Chinese
(Traditional Chinese, Japanese and Russian are available per request)
NIST Traceable: NIST traceable calibration with data
(included)
10
Look us up on www.additel.com or call today (1)714-998-6899
SPECIFICATIONS
Control Stability
<0.005%FS
[1]
;
ADT761-LLP: < 0.05 Pa (0.0002 inH
2
O)
Pressure Connections
Pressure connection: ADT761-L/M/H/LA/MA/HA
One ADT100-761 Hose Test Kit with quick connector
1/8 BSP Female on calibrator
Two 1/4NPT(or 1/2NPT, 1/4BSP, 1/2BSP, M20×1.5) female hand-tight connectors on the external pressure manifold
Pressure connection: ADT761-LLP/BP
Stainless steel hose barb fitting
External Pressure Module Connection
Accepts Intelligent Pressure Module
Electrical Connection
0.156 inch (Ø4mm) banana sockets
Documenting and on-demand logging
Task management capability
Internal memory stores 200 tasks
Download tasks and upload results
Display
7" LCD color screen (800×480)
Display rate: 5 readings per second
Resolution 4, 5 or 6 digit, user selectable
Pressure Units
Pa, kPa, MPa, psi, bar, mbar, inH mmH
2
O@4°C, inH
2
O@20°C, mmH inHg@0°C, mmHg@0°C, kgf/cm
2
BP)
2
O@4°C,
2
O@20°C,
, and hPa (ADT761-
Pump life: >100,000 cycles
Power
Battery: Rechargeable Li-ion Polymer battery (included)
Li-Battery working time: ~8 hours
Recharge time: ~3 hours
External Power: 110/220V Power adapter (DC 27 V)
(Included)
Environmental Specification:
Operating temperature: 32°F to 122°F (0°C to 50°C)
Compensated Temperature: 32°F to 122°F (0°C to
50°C)
Storage temperature: -20°C to 60°C (-4°F to 120°F)
Humidity: <90%, non-condensing
European Compliance: CE Marked
Communication
RS232 (DB9/F, environmentally sealed)
Baud rate: 2400, 4800, 9600, 19200, 38400, 57600,
115200
Data length: 7 Bits, 8 Bits
Stop bit: 1 Bit, 2 Bits
Address: from 1 to 121
Dimension
11.65 X 7.32 X 7.09 in (296 X186 X180 mm)
Weight: 12.4 to 16.3 lb (5.6 to 7.4 kg)
Warranty: 18 months
[1] FS specification applies to the span of the range
Task Manual
Built-in User's Manual
Pressure gauge / transmitter / switch calibration
Documenting
Look us up on www.additel.com or call today (1)714-998-6899
11
Additel 761
Automated Pressure Calibrators
SPECIFICATIONS
Pressure Ranges
Type
Low/Differential
Pressure
Gauge Pressure
Gauge/Absolute
Pressure
Model
ADT761-LLP
ADT761-D
ADT761-L
ADT761-M
ADT761-H
ADT761-LA
ADT761-MA
ADT761-HA
Pressure Range
-25 to 25 mbar
(-10 to 10 inH
2
O)
-0.95 to 1 bar
(-13.5 to 15 psi)
-0.95 to 7 bar
(-13.5 to 100 psi)
-0.90 to 25 bar
(-13 to 375 psi)
-0.90 to 40 bar
(-13 to 600 psi)
-0.95 to 7 bar
(-13.5 to 100 psi)
0.05 to 8 bar.a
(1.2 to 115 psi.a)
-0.90 to 25 bar
(-13 to 375 psi)
0.1 to 26 bar.a
(1.7 to 390 psi.a)
-0.90 to 40 bar
(-13 to 600 psi)
0.1 to 41 bar.a
(1.7 to 615 psi.a)
100 to 1,200 hPa 100 to 1,200 hPa
Pressure Module 1
Range Accuracy
[1]
-2.5 to 2.5 mbar
(-1 to 1 inH
2
O)
-25 to 25 mbar
(-10 to 10 inH
2
O)
-0.95 to 2.5 bar
(-13.5 to 35 psi)
-0.9 to 2.5 bar
(-13 to 35 psi)
-0.9 to 2.5 bar
(-13 to 35 psi)
-0.95 to 2.5 bar
(-13.5 to 35 psi)
0.05 to 3.5 bar.a
(1.2 to 50 psi.a)
-0.9 to 2.5 bar
(-13 to 35 psi)
0.1 to 3.5 bar.a
(1.7 to 50 psi.a)
-0.9 to 2.5 bar
(-13 to 35 psi)
0.1 to 3.5 bar.a
(1.7 to 50 psi.a)
0.05%FS
[2]
0.05%FS
[2]
0.02%FS
0.02%FS
0.02%FS
0.02%FS
0.03%FS
0.02%FS
0.03%FS
0.02%FS
0.03%FS
0.01%FS
Pressure Module 2
Range Accuracy
[1]
-25 to 25 mbar
(-10 to 10 inH
2
O)
-0.95 to 1 bar
(-13.5 to 15 psi)
0 to 7 bar
(0 to 100 psi)
0 to 25 bar
(0 to 375 psi)
0 to 40 bar
(0 to 600 psi)
-0.95 to 7 bar
(-13.5 to 100 psi)
0.05 to 8 bar.a
(1.2 to 115 psi.a)
-0.9 to 25 bar
(-13 to 375 psi)
0.1 to 26 bar.a
(1.7 to 390 psi.a)
-0.9 to 40 bar
(-13 to 600 psi)
0.1 to 41 bar.a
(1.7 to 615 psi.a)
0.05%FS
[2]
0.02%FS
0.02%FS
0.02%FS
0.02%FS
0.02%FS
0.025%FS
0.02%FS
0.025%FS
0.02%FS
0.025%FS
NA NA Barometric pressure ADT761-BP
[1] One year accuracy (including yearly stability). FS specification applies to the span of the module range.
[2] 0.05% FS accuracy (including months stability). One year accuracy is 0.05% FS calibration accuracy combined with 0.05% FS one year stability.
* Additel 761 calibrators support 160A series intelligent digital pressure modules that are available for gauge, vacuum and absolute pressure from -15 psi to 10,000 psi (-1 bar to 700 bar). Accuracy from 0.02%FS includes operation over 14°F to 122°F (-10°C to 50°C), one year stability and calibration uncertainty. For detailed specification refer to 160A series pressure modules datasheet.
Electrical Measurement and Source Accuracy
Voltage Measurement
Current Measurement
Current Source
Switch Test
DC 24V output
Range Resolution Accuracy
±30.0000V
±30.0000mA
0.000 to 22.000mA
0.1mV
0.1μA
1μA
±(0.01%RD + 1.5mV)
±(0.01%RD + 1.5μA)
±(0.02%RD + 2.2μA)
If the switch has detective Voltage, the range is from 3V to 24V
24V ± 0.5V, max: 50mA
12
Look us up on www.additel.com or call today (1)714-998-6899
Additel 761
Automated Pressure Calibrators
ORDERING INFORMATION
Model Number
ADT761 L N
Pressure range:
See pressure range table.
Pressure port type on External
Pressure Manifold:
N - 1/4NPT female
N2 - 1/2NPT female
B - 1/4BSP female
B2 - 1/2BSP female
M - M20X1.5 female
Accessories (included)
External Pressure
Manifold (ADT106)
(Except 761-LLP)
9818
110V/220V external
Power adapter
9722
Chargeable Li-ion battery
9022
Test Leads for calibrator
9020
Short circuit cable
9907
Carrying case for 761 calibrator and accessory
9060
Pressure module connection cable
9240
DP gauge holder, rubber
(Only for ADT761-LLP)
ADT100-761
(Except 761-LLP)
O-rings(Except 761-LLP)
1 pc
1 pc
1 pc
2 sets
(4 pcs)
1 set
(2 pcs)
1 pc
1 pc
1 pc
1 pc
Manual
20 pcs
1 pc
Allen wrench 1 set
ADT100-761Hose
(Except 761-LLP: 2 pcs)
NIST traceable calibration certificate
1 pcs
1 pc
* Additel/Land software could be downloaded for free at www.additel.com
Optional Accessories
Model Number
ADT100-761-N4
Description
Hose Test Kit, 5 feet flexible hose, 0.156"
(Ø4mm) tube to 1/4NPT hand-tight quick connector
ADT100-761-B4
ADT106-N
ADT106-B
ADT106-M
Hose Test Kit, 5 feet flexible hose, 0.156"
(Ø4mm) tube to 1/4BSP hand-tight quick connector
External Pressure
Manifold (with two
1/4NPT hand-tight quick connectors)
External Pressure
Manifold (with two
1/4BSP hand-tight quick connectors)
External Pressure
Manifold (with two
M20X1.5 hand-tight quick connectors)
ADT160A
Pressure modules
(please check Additel
160A datasheet)
9050
USB to RS232 (DB9/M)
Adapter
9060
Pressure module connection cable
9510
Additel/Cal task management software
Picture
ADT100-761Hose ADT761 hose, 5 feet
Look us up on www.additel.com or call today (1)714-998-6899
13
14
Additel Pressure Gauge
Selection Guide
Series
Feature
ADT672 Series
Digital Pressure Calibrator
ADT681 Series
Digital Pressure Gauge
ADT680 Series
Digital Pressure Gauge
Gauge Pressure
Compound Pressure
Absolute Pressure
Differential Pressure
Accuracy Classes
•
•
•
•
0.02% & 0.05%FS
15K & 20K psi: 0.05%FS
> 20K psi: 0.1%FS
•
•
•
•
0.02%, 0.05%, 0.1%, & 0.2%FS & 0.1%RD
15K & 20K psi: 0.05%, 0.1%, 0.2%FS &
0.1%RD
>20K psi: 0.1% & 0.2%FS
•
•
•
0.05%, 0.1%, & 0.25%FS
> 20K psi: 0.1% & 0.25%FS
Digital Display
Analog Display (Fan-Shaped
Indication)
Fully Temperature Compensation from -10°C to 50°C
Resolution
6-Digit Resolution
5-Digit Resolution
Selectable Pressure Units
Backlight
Over Pressure Indication
IS Certification (optional – not available for panel mount)
IP67 Certification
Panel Mount (optional)
Communication
Wireless
Data Logging
Min/Max
Built-in Leak Test
HART Communication
Measure mA and V
24V Loop Power
Switch Test
NIST-Traceable Certificate of
Calibration
Power
•
•
•
•
11
•
•
•
•
•
•
•
•
•
•
11
•
•
•
•
•
•
•
Optional
•
•
Rechargeable battery 9V battery (120/220V adapter is optional)
Series
Pressure Range
Pressure psi bar
Media
Gauge
V15
GP5
GP10
-15 to 0
0 to 5
0 to 10
-1 to 0
0 to 0.35
0 to 0.7
G
G
G
GP15
GP30
GP50
GP100
0 to 15
0 to 30
0 to 50
0 to 100
0 to 1
0 to 2
0 to 3.5
0 to 7
G, L
G, L
G, L
G, L
GP300
0 to 300 0 to 10 G, L
GP500
0 to 500 0 to 35 G, L
Look us up on www.additel.com or call today (1)714-998-6899
ADT672 Series
Digital Pressure Calibrator
•
•
•
•
•
•
•
•
•
ADT681 Series
Digital Pressure Gauge
•
•
•
•
•
•
•
•
•
•
•
•
19
•
•
•
680W only
680W only
•
•
•
2AA batteries
ADT680 Series
Digital Pressure Gauge
•
•
•
•
•
•
Series
Pressure
Pressure Range
Compound
CP2
CP5
CP10
CP15
CP30
CP100
CP300
Absolute
AP5
AP10
AP15
AP30
AP50
AP100
AP300
AP500
AP1K
AP3K
GP600
GP1K
GP2K
GP3K
GP5K
GP10K
GP15K
GP20K
GP25K
GP30K
GP36K
GP40K psi
0 to 600
0 to 1K
0 to 2K
0 to 3K
0 to 5K
0 to 10K
0 to 15K
0 to 20K
0 to 25K
0 to 30K
0 to 36K
0 to 40K
±2
±5
±10
±15
-15 to 30
-15 to 100
-15 to 300
5
10
15
30
50
100
300
500
1K
3K
AP5K
DP300
5K
Differential inH
2
O mbar
DP1
±1 ±2.5
DP2
±2 ±5
DP5
DP10
DP20
DP30
±5
±10
±20
±30
±10
±25
±50
±75
DP50
DP150
±50
±150
±160
±350
±300
350
±700
0.35
0.7
1
2
3.5
7
20
35
70
200
±0.16
±0.35
±0.7
±1
-1 to 2
-1 to 7
-1 to 20
bar
0 to 40
0 to 70
0 to 140
0 to 200
0 to 350
0 to 700
0 to 1K
0 to 1.4K
0 to 1.6K
0 to 2K
0 to 2.5K
0 to 2.8K
G
G
G
G
G
G, L
G, L
G, L
G, L
G, L
G, L
G
G
G
G
G
G, L
G, L
Media
G, L
G, L
G, L
G, L
G, L
G, L
G, L
G, L
G, L
G, L
G, L
G, L
G
G
G
G
G
G
G
G
G
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
ADT672 Series
Digital Pressure Calibrator
ADT681 Series
Digital Pressure Gauge
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
ADT680 Series
Digital Pressure Gauge
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Look us up on www.additel.com or call today (1)714-998-6899
15
Additel 672
Digital Pressure Calibrators
Pressure ranges to 40,000 psi (2,800 bar)
HART Communication capability
Measure mA or V, and with 24V loop power
Easy-to-use, inexpensive pressure calibrator with uncertainty better than 0.02%FS
16
Gauge pressure Differential pressure
OVERVIEW
At first glance, the 672 series precision pressure calibrators look like an ordinary pressure gauge. But this series is much more than ordinary, and definitely more than just a pressure gauge—it’s a pressure calibrator! With advanced microprocessor technology and state-of-the-art silicon pressure sensors, the 672 series precision pressure calibrators provide a pressure calibration solution for gauges, transmitters, and switches over a wide pressure range. The 672 is the size of a pressure gauge but with the functionality of a calibrator: It measures pressure precisely with a builtin pressure sensor, as well as reads the current or mV produced by a transducer. It can even supply an excitation voltage to power sensors or transmitters during calibration. In order to reach 0.02%FS accuracy up to 10,000 psi
(700 bar) and 0.1%FS accuracy up to 40,000 psi (2,800 bar), every silicon pressure sensor has been specially aged, tested, and screened before assembly. The 672 series precision pressure calibrators are unmatched in performance and reliability.
FEATURES
Pressure ranges to 40,000 psi (2800 bar)
Measure mA with 0.01% RD + 1.5 μA accuracy
Measure V with 0.01% RD + 1.5 mV accuracy
Power transmitters during test using 24V loop supply
Pressure switch test
HART Communication capability
Advanced temperature compensation
Dual readout
Min/Max/Hold to capture changing measurements
Data logging
Large, easy to read display with 6-digit resolution
Backlit display
Rechargeable battery or AC adapter
NIST traceable calibration with data (Included)
SPECIFICATIONS
Accuracy
ADT672-02: 0.02% of full scale
ADT672-05: 0.05% of full scale
>20,000 (1,400 bar): 0.1% FS
Gauge Types
Gauge pressure
Compound Pressure
Absolute pressure
Differential pressure
Display
Description: Dual-line 6 full digit FSTN LCD with LED
Backlight
Display rate: 3.5 readings per second (Default setting)
Numeral display height: 16.5mm (0.65")
Pressure Units
Pa, kPa, MPa, psi, bar, mbar, inH
2
O@4°C, mmH
2
O@4°C, inHg@0°C, mmHg@0°C, kgf/cm
2
Environmental
Compensated Temperature: 14°F to 122°F (-10°C to
50°C)
Operating Temperature: 14°F to 122°F (-10°C to
50°C)
Storage Temperature: -4°F to 158°F (-20°C to 70°C)
Humidity: <95%
Look us up on www.additel.com or call today (1)714-998-6899
SPECIFICATIONS
Pressure Ranges
Gauge Pressure
[1]
P/N
V15
GP2
GP5
GP10
GP15
GP30
GP50
GP100
GP300
GP500
GP600
GP1K
GP2K
500
600
1,000
2,000
GP3K
GP5K
3,000
5,000
GP10K 10,000
GP15K 15,000
GP20K 20,000
GP25K 25,000
GP30K 30,000
GP36K 36,000
GP40K 40,000
5
10
15
30
50
100
300
Pressure Range
(psi)
-15
2
(bar)
-1.0
0.16
0.35
0.7
1.0
2.0
3.5
7.0
20
1,000
1,400
1,600
2,000
2,500
2,800
35
40
70
140
200
350
700
Media
[2]
G, L
G, L
G, L
G, L
G, L
G, L
G, L
G, L
G, L
G, L
G
G
G
G
G, L
[3]
G, L
[3]
G, L
G, L
G, L
G, L
G, L
G, L
[1] Sealed gauge pressure for above 1000 psi
[2] G=Gas, L=Liquid
[3] 0.02% FS for gas media only
Accuracy(%FS)
0.02 (0.05)
0.02 (0.05)
0.02 (0.05)
0.02 (0.05)
0.02 (0.05)
0.02 (0.05)
0.02 (0.05)
0.05 (0.1)
0.05 (0.1)
0.1
0.1
0.1
0.1
0.02 (0.05)
0.05
0.05
0.02 (0.05)
0.02 (0.05)
0.02 (0.05)
0.02 (0.05)
0.02 (0.05)
0.02 (0.05)
Burst
Pressure
2×
1.5×
1.5×
1.5×
1.5×
1.1×
3×
3×
3×
3×
3×
3×
3×
3×
3×
3×
3×
3×
3×
3×
3×
3×
Compound Pressure
P/N
CP2
CP5
CP10
CP15
Pressure Range
(psi) (bar)
±2
±5
±10
±15
±0.16
±0.35
±0.7
±1
CP30 -15 to 30 -1 to 2
CP100 -15 to 100 -1 to 7
Media
G
G, L
CP300 -15 to 300 -1 to 20 G, L
G
G
G
G
Accuracy(%FS)
[1]
0.05
0.02 (0.05)
0.02 (0.05)
0.02 (0.05)
0.02 (0.05)
0.02 (0.05)
0.02 (0.05)
[1] FS specification applies to the span of the range
Burst
Pressure
3×
3×
3×
3×
3×
3×
3×
Absolute Pressure
P/N
AP5
AP10
AP15
AP30
AP50
AP100
AP300
AP500
50
100
300
500
AP1K 1,000
AP3K 3,000
AP5K 5,000
Pressure Range
(psi)
5
(bar)
0.35
10
15
30
0.7
1.0
2.0
3.5
7.0
20
35
70
200
350
Media
G
G , L
G , L
G , L
G , L
G , L
G , L
G
G
G
G
0.1
0.1
0.1
0.1
0.1
0.05 (0.1)
0.05 (0.1)
0.05 (0.1)
0.05 (0.1)
0.05 (0.1)
0.05 (0.1)
Accuracy(%FS)
Burst
Pressure
3×
3×
3×
3×
3×
3×
3×
3×
3×
3×
3×
Differential Pressure
P/N
DP1
DP2
DP5
DP10
DP20
DP30
DP50
DP150
DP300
Pressure Range
(inH
2
±1
O) (mbar)
±2.5
±2
±5
±5.0
±10
±10
±20
±30
±50
±150
±300
±25
±50
±75
±160
±350
±700
Media
G
G
G
G
G
G
G
G
G
Accuracy
(%FS)
0.05
[2]
100×
0.05
[2]
0.05
[2]
0.05
[2]
0.05
0.05
[1]
Burst
Pressure
100×
50×
20×
20×
20×
Static
Pressure
Range
±10 psi
±10 psi
±10 psi
±10 psi
±10 psi
0.05
0.02
0.02
3×
3×
3×
±10 psi
±10 psi
50 psi
50 psi
[1] FS specification applies to the span of the range. Accuracy includes one year stability.
[2] 0.05%FS accuracy (incl 6 months stability). One year accuracy is
0.05%FS calibration accuracy combined with 0.05%FS one year stability.
Electrical Measurement Accuracy
Voltage DC
Current DC
DC 24V
Switch
[1]
Range Accuracy
±30.0000V
±30.0000mA
± (0.01%RD + 1.5 mV)
± (0.01%RD + 1.5 μA)
24V±0.5V max:50mA Protect at: 120mA
Status OPEN/CLOSED
[1] 1V~12V if switch has detective voltage
Look us up on www.additel.com or call today (1)714-998-6899
17
18
Additel 672
Digital Pressure Calibrators
SPECIFICATIONS
Pressure Connections
1/4NPT male, 1/2NPT male, 1/4BSP male, 1/2BSP male, M20X1.5 male (≤15,000 psi)
1/4HP female or 1/4HP male (>15,000 psi)
1/4HP female: Autoclave F-250-C, 9/16" - 18 UNF-2B
1/4HP male: Autoclave M-250-C, 9/16" - 18 UNF-2A
0.236 inch (Ø6mm) test hose (for differential pressure)
Other connections available per request
Electrical Connection
0.156 inch (Ø4mm) sockets
Over Pressure Warning: 120%
Data Logging
Storage capacity: 30 files, 40 records per file
Mode: manual and automatic
Hourly-record: record the data every hour
Interval-record: set by user
Power
Battery: Rechargeable Li-ion polymer battery
Li-Battery working time: 40 hours
Recharge time: 4 hours
External power: 110V/220V power adapter (DC10V)
Enclosure
Case material: Aluminum alloy
Wetted parts: 316L SS
Dimension: Ø120mm X 46mm depth X 184mm height
Weight: 0.7kg
European Compliance: CE marked
Communication
RS232 (DB9/F, environmentally sealed)
Baud rate: 1200,2400,4800,9600
Data length: 8 bits
Stop bit: 2 bits
Address: from 1 to 112
Warranty:1 year
ORDERING INFORMATION
Model Number
ADT672 02 GP300 PSI N
Model Range type:
PSI-range by psi
BAR-range by bar
H
2
O-range by inH
2
O
Accuracy:
02-0.02% of full scale
05-0.05% of full scale
10-0.1% of full scale
Pressure port type:
N-1/4NPT male
N2-1/2NPT male
B-1/4BSP male
B2-1/2BSP male
M-M20X1.5 male
AF-Autoclave F-250-C female
AM-Autoclave M-250-C male
Pressure range P/N:
See pressure range table
Look us up on www.additel.com or call today (1)714-998-6899
Accessories included
110V/220V external power adapter (DC 10V)
2 pieces 1.5-meter test leads
2 pieces 0.236 inch (Ø6 mm) test hose
(for differential pressure gauge only)
Additel/Land software
(free download at www.additel.com)
Manual
NIST traceable calibration certificate
Optional Accessories
Model number
9702
9816
9502
9506
Description
Spare rechargeable Li-ion polymer battery for 672
Spare 110V/220V external power adapter (DC 10V) for ADT22X and ADT672 calibrator
Additel/Log II real time data logging and graphical software for 681 and 672
Additel/PCal pressure calibration software
9050 USB to RS232 (DB9/M) Adapter
9900-672 Carrying Case for one 672 digital pressure gauge
9021 Spare 2 pieces test leads (1.5-meter) for 672
Application Note
Understanding Accuracy Specifications for Digital Pressure Sensors – Percentage of Full Scale Versus
Percentage of Reading
Specifications for digital pressure gauges can sometimes seem confusing or overwhelming, especially, if you are unfamiliar with the terminology. Some pressure sensors will specify accuracy as a percent of full scale (FS) while others provide the specification as a percent of reading. So why are there different ways of specifying the accuracy of pressure sensors and is percent of reading more accurate than percent of full scale or vise versa? This brief technical note will discuss the two differences and answer these questions.
Percentage of Reading Accuracy
psi
60
70
80
90
100
0
10
20
30
40
50
Figure 1 - Percent reading accuracy example
Full scale: 0 to 100 psi
Accuracy: 20 to 100% FS: 0.1% of reading
0 to 20% FS: 0.02% of FS
Accuracy
(psi)
0.06
0.07
0.08
0.09
0.10
0.02
0.02
0.02
0.03
0.04
0.05
0.02%FS
0.1% of
Reading
Accuracy as a percentage of reading is accomplished by multiplying the accuracy percentage by the pressure reading. Thus, the lower the pressure measurement, the better the accuracy. Instruments that have a percent reading specification are accompanied with a floor specification. The floor specification takes into account uncertainties such as resolution and measurement noise which may be negligible at higher pressures but are of much more significance at lower pressures.
For example, an accuracy specification may read 0.1% of reading for 20 to 100% of range and 0.02% of full scale below 20% of the range. The 0.02% of full scale specification is considered the floor specification. To understand the accuracy of the sensor, the user is then required to know where the floor spec is applicable and the full scale of the sensor.
This method of specification is often used because it aligns well with the typical performance of pressure gauges. Typically, the closer you measure to barometric pressure the better the performance of the gauge. Figures 1 and the graph below show an example specification for a 100 psi gauge and its accuracy in psi.
Look us up on www.additel.com or call today (1)714-998-6899
19
Percentage of Full Scale Accuracy
psi
60
70
80
90
100
0
10
20
30
40
50
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
Accuracy
(psi)
0.05%FS
Accuracy as a percentage of full scale is calculated by multiplying the accuracy percentage by the full scale pressure of the gauge. This is obviously a more simple method of specification and is most commonly used in industry because it is easy to calculate and interpret. Denoting the accuracy as percent full scale is a more conservative way of specifying the pressure sensor because typically the sensor doesn't perform the same over its full range. It usually will perform more accurately as you approach barometric pressure. This type of specification is most common for industrial gauges which make it easier to compare one gauge versus another. Figure 2 is an example specification for a 100 psi gauge and its accuracy in psi.
A Comparison of Percent of Full Scale and Percent of Reading Accuracies
psi
50
60
70
80
90
100
0
10
20
30
40
0.1% of
Reading
0.02
Accuracy
(psi)
0.05% of FS
0.05
0.02
0.02
0.03
0.04
0.05
0.06
0.07
0.08
0.09
0.10
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
So you may ask, "Which is more accurate?" The answer is that it depends on the pressure being measured. In the two examples given, the gauge specified at 0.1% of reading is more accurate as you measure lower pressures in its range. However, as you move above 50% of the range, the gauge specified at 0.05% of full scale becomes more accurate than the 0.1% of reading gauge. This can be seen clearly in the chart (left) and graph (below) where the two gauges are compared in terms of psi accuracy. To properly compare these, two gauges you should convert the accuracy to pressure units, such as psi or bar. Then they can be properly matched one against another in like units of measure.
In conclusion, one method of specification is not better than another, it is just different. Given this difference it becomes important to know how to interpret the different specifications types and be able to compare one versus another.
20
Look us up on www.additel.com or call today (1)714-998-6899
Additel 681
Digital Pressure Gauges
Pressure ranges to 40,000 psi (2,800 bar)
0.02%, 0.05%, 0.1%, 0.2% FS or 0.1%RD accuracy
% pressure indication with fan-shaped graph scale for visual reference
Now IP67 Rated!
Fully temperature compensated accuracy
Panel mount gauges are available
Intrinsically safe version (681IS)
Data logging option
IP67 rated (681IS)
Gauge pressure
OVERVIEW
Differential pressure
With advanced microprocessor technology and state-of-the-art silicon pressure sensors, the 681 series digital pressure gauges provide an accurate, reliable, and economic solution for a wide range of pressure applications.
They are loaded with functionality and remarkably easy to use. To reach the best performance, every silicon pressure sensor in our gauges is specially aged, tested and screened before assembly. At Additel, fully temperature compensated accuracy means every sensor is pressure tested at several environmental temperatures from
-10°C to 50°C. With this test data individual coefficients are generated and stored in the gauge characterizing its performance over the full temperature compensated range. And now the ADT681IS comes with an IP67 rating meaning it is dust resistant and water proof, submersible in 1 meter of water.
Designed to fit your need
Additel pressure gauges give you the widest variety of sensor choices on the market. Whether you require low inches of water measurement or very high pressure measurement, we have a gauge that will meet your need. We offer sensors which are ±1 inH
2
O (±2.5 mbar) to 40K psi (2,800 bar) and everything in between.
Do your applications require you to measure both positive and vacuum pressure? Our compound gauges do not compromise accuracy and provides you with the same high accuracy specification on both positive and vacuum pressures. We offer a wide variety up to 300 psi (20 bar). If you need a higher range, just contact us and we can likely customize one to meet your need. We also offer absolute pressure sensors to 5K psi (350 bar) and a full range of differential pressure sensors from ±1 inH
2
O (±2.5 mbar) to ±300 inH
2
O (±700 mbar). Are you looking for a pressure gauge to use in hazardous areas? Our ATEX-certified intrinsically safe models (681IS) are designed for pressure measurement in hazardous areas.
If you need to panel mount our sensors, we offer the option (see ordering information) for a back-mounted pressure port and gauge housing designed to fit in a panel. And most recently, we've added the option to do stand-alone data logging with the 681. Now you can record more than 21,000 records internal to the 681 series. Each record includes date, time, pressure and temperature readings. Download the logged data with our free Additel/Land software or you can purchase our Additel/Log II for real-time logging and data analysis. The 681 series digital pressure gauges are unmatched in performance and reliability. Best of all, they are very affordable.
FEATURES
Pressure ranges to 40,000 psi (2,800 bar)
0.02% full scale accuracy (681-02)
0.05% full scale accuracy (681-05)
0.1% full scale accuracy (681-10)
0.2% full scale accuracy (681-20)
0.1% reading scale accuracy (681-RD)
IP67 rated: Submersible in 1 meter of water(681IS)
Fully temperature compensated accuracy from
14°F to 122°F (-10°C to 50°C)
Up to eleven selectable pressure units
Large, easy to read display with 5-digit resolution
Backlit display
% pressure indication with fan-shaped graph scale for visual reference
Display flash warning when pressure over 120% of FS
Bottom mount or panel mount
ATEX certified intrinsically safe (Model 681IS)
NIST traceable calibration with data(included)
9V battery power or AC adapter (optional)
Data logging to 21,843 records (includes date, time, pressure and temperature)
Look us up on www.additel.com or call today (1)714-998-6899
21
22
SPECIFICATIONS
Model
ADT681: Regular gauge
ADT681IS: ATEX certified intrinsically safe
Accuracy
681(IS)-02 : 0.02% of full scale
681(IS)-05 : 0.05% of full scale
681(IS)-10 : 0.1% of full scale
681(IS)-20 : 0.2% of full scale
681(IS)-RD: 0% to 20% of Range: 0.02% of full scale
20% to 110% of Range: 0.1% of reading
Vacuum: 0.25% of full scale
[1][2]
[1] FS = -14.5 psi
[2] Applicable ADT681-RD-CPX
(For detailed accuracy, please see pressure range table)
Gauge Types
Gauge pressure
Compound pressure
Absolute pressure
Differential pressure
Fan-shaped Graph Scale
Similar to analog dials, including pressure swing,
% indication with fan-shaped graph scale for visual reference, low/high alarm.
Display
Description: 5 full digit FSTN LCD
Display rate: 3 readings per second (Default setting).
Adjustable from 10 readings per second to 1 reading every ten seconds
Numeral display height: 16.5mm (0.65")
Pressure Units
Pa, kPa, MPa, psi, bar, mbar, kgf/cm
2 mmH
2
, inH
O@4°C, inHg@0°C, mmHg@0°C
2
O@4°C
Environmental
Compensated Temperature: 14°F to 122°F (-10°C to
50°C)
Operating Temperature: 14°F to 122°F (-10°C to 50°C)
Storage Temperature: -4°F to 158°F (-20°C to 70°C)
Humidity: <95%
Pressure Port
1/4NPT male, 1/2NPT male, 1/4BSP male, 1/2BSP male, M20×1.5 male (≤15,000 psi)
1/4HP female or 1/4HP male(≥15,000 PSI)
*1/4HP female: Autoclave F-250-C, 9/16" - 18 UNF-2B
*1/4HP male: Autoclave M-250-C, 9/16" - 18 UNF-2A
0.236 inch (Ø6 mm) test hose (for differential pressure)
Other connections available per request
Power
Battery: One 9V alkaline battery (included)
Battery life: 300 hours (10 readings/s), 600 hours (3 reading/s), or 6000 hours (1 reading/10s)
Power auto-off: 60 minutes power auto-off. Auto-off may be disable
External power: 110/220V external power adapter
(optional)
Look us up on www.additel.com or call today (1)714-998-6899
Enclosure
Case material: Aluminum alloy
Wetted parts: 316L SS
Dimension: Ø110mm X 35mm depth X 176mm height
(panel mount gauge: Ø140mm X 86mm depth)
Weight: 0.6kg
Compliance
Protection Level: IP67(available for 681IS GP15-40K)
Vibration: 5g (20-2000 Hz)
Shock Resistance: 100g/11ms
Data Logging
Data storage: 21,843 records (each record includes date, time, pressure and temperature)
Rate: user-selectable from 1 to 99,999 second intervals
Intrinsic Safety and European Compliance
CE marked
ATEX certified intrinsically safe (ADT681IS)
II 1G EX ia IIC T4 Ga
Communication: RS232
*(Do not use the RS-232 connector in a hazardous atmosphere)
Warranty: 1 year
Pressure Ranges
Gauge Pressure
[1]
P/N
Pressure Range Media
[2]
(psi) (bar)
-15 -1.0
G
Accuracy
%FS %RD
0.02 (0.05, 0.1, 0.2) N/A V15
GP2
GP5
GP10
GP15
GP30
GP50
2
5
10
15
30
50
GP100 100
0.16
0.35
0.7
2.0
3.5
7.0
G
G
G
1.0
G, L
[3]
G, L
[3]
0.05 (0.1, 0.2)
0.05 (0.1, 0.2)
0.02 (0.05, 0.1, 0.2)
0.02 (0.05, 0.1, 0.2)
0.02 (0.05, 0.1, 0.2)
G, L 0.02 (0.05, 0.1, 0.2)
G, L 0.02 (0.05, 0.1, 0.2)
N/A
0.1
0.1
0.1
0.1
0.1
0.1
GP300 300
GP500 500
GP600 600
GP1K 1,000
20
35
40
70
G, L 0.02 (0.05, 0.1, 0.2)
G, L 0.02 (0.05, 0.1, 0.2)
G, L 0.02 (0.05, 0.1, 0.2)
G, L 0.02 (0.05, 0.1, 0.2)
GP2K 2,000
GP3K 3,000
140 G, L 0.02 (0.05, 0.1, 0.2)
200 G, L 0.02 (0.05, 0.1, 0.2)
GP5K 5,000 350 G, L 0.02 (0.05, 0.1, 0.2)
GP10K 10,000 700 G, L 0.02 (0.05, 0.1, 0.2)
GP15K 15,000 1,000 G, L 0.05 (0.1,0.2)
GP20K 20,000 1,400 G, L
GP25K 25,000 1,600 G, L
GP30K 30,000 2,000 G, L
GP36K 36,000 2,500 G, L
0.05 (0.1,0.2)
0.1 (0.2)
0.1 (0.2)
0.1 (0.2)
GP40K 40,000 2,800 G, L 0.1 (0.2)
[1] Sealed gauge pressure for above 1,000 psi
[2] G=Gas, L=Liquid
[3] 0.02% FS for gas media only
N/A
N/A
N/A
N/A
N/A
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
Burst
Pressure
3×
3×
3×
3×
2×
3×
3×
3×
3×
1.5×
1.5×
1.5×
1.5×
1.1×
3×
3×
3×
3×
3×
3×
3×
3×
Additel 681 Digital Pressure Gauges
Absolute Pressure
P/N
AP5
AP10
AP15
AP30
AP50
AP100
AP300
AP500
AP1K 1,000
AP3K 3,000
AP5K 5,000
[1] G=Gas, L=Liquid
Pressure Range
(psi)
5
(bar)
0.35
10
15
30
50
100
300
500
7.0
20
35
0.7
1.0
2.0
3.5
70
200
350
Media
[1]
G
G
G, L
G, L
G, L
G
G
G
G, L
G, L
G, L
Accuracy(%FS)
0.1 (0.2)
0.1 (0.2)
0.1 (0.2)
0.1 (0.2)
0.1 (0.2)
0.05 (0.1, 0.2)
0.05 (0.1, 0.2)
0.05 (0.1, 0.2)
0.05 (0.1, 0.2)
0.05 (0.1, 0.2)
0.05 (0.1, 0.2)
Burst
Pressure
3×
3×
3×
3×
3×
3×
3×
3×
3×
3×
3×
ORDERING INFORMATION
Model Number
ADT681 02 GP300 PSI N PB DL
DP1
DP2
DP5
DP10
DP20
DP30
DP50
DP150
DP300
Differential Pressure
P/N
Pressure Range
±2
Media
(inH
2
O) (mbar)
±1 ±2.5
G
±5.0 G
±5 ±10
±10 ±25
±20 ±50
G
G
G
±30
±50
±150
±300
±75
±160
±350
±700
G
G
G
G
Accuracy
(%FS)
[1]
0.05
[2]
100×
0.05
[2]
0.05
[2]
100×
50×
0.05
[2]
0.05
20×
20×
0.05
0.05
20×
3×
0.02 (0.05)
0.02 (0.05)
3×
3×
Burst
Pressure
Static
Pressure
Range
±10 psi
±10 psi
±10 psi
±10 psi
±10 psi
±10 psi
±10 psi
50 psi
50 psi
[1] FS specification applies to the span of the range. Accuracy includes one year stability.
[2] 0.05%FS accuracy (incl 6 months stability). One year accuracy is
0.05%FS calibration accuracy combined with 0.05%FS one year stability.
Compound Pressure [1]
P/N
CP2
CP5
CP10
CP15
CP30
Pressure Range
(psi)
±2
(bar)
±0.16
Media
[2]
G
±5 ±0.35
G
Accuracy
%FS
[3]
%RD
0.05 (0.1,0.2) N/A
0.02 (0.05,0.1,0.2) 0.1
Burst
Pressure
3×
3×
±10
±15
±0.7
±1
-15 to 30 -1 to 2
G
G
G
0.02 (0.05,0.1,0.2)
0.02 (0.05,0.1,0.2)
0.02 (0.05,0.1,0.2)
0.1
0.1
0.1
CP100 -15 to 100 -1 to 7 G, L 0.02 (0.05,0.1,0.2) 0.1
CP300 -15 to 300
-1 to
20
G, L 0.02 (0.05,0.1,0.2)
[1] Sealed gauge pressure for above 1,000 psi.
[2] G=Gas, L=Liquid
[3] FS specification applies to the span of the range.
0.1
3×
3×
3×
3×
3×
Model:
ADT681
ADT681IS
Accuracy:
02-0.02% of full scale
05-0.05% of full scale
10-0.1% of full scale
20-0.2% of full scale
RD-0.1% of reading
Pressure range P/N:
See pressure range table
Range type:
PSI-range by psi
BAR-range by bar
H
2
O-range by inH
2
O
Pressure port type:
N- 1/4NPT male
N2- 1/2NPT male
B-1/4BSP male
B2-1/2BSP male
M-M20X1.5 male
AF-Autoclave F-250-C female
AM-Autoclave M-250-C male
PB: Panel mount with back pressure port
DL: Data logging
Accessories included
Rubber boot (Except panel mount)
9V alkaline battery (1 pc)
Manual
NIST traceable calibration certificate
Optional Accessories
Model number
9812
9502
9506
Description
110V/220V external power adapter (DC 9V) for 681 digital pressure gauge.
Additel/Log II real time data logging and graphical software for 681 and 672.
Additel/PCal pressure calibration software
9050 USB to RS232 (DB9/M) Adapter
9900-681
9251
Carrying Case for one 681 digital pressure gauge
Rubber boot for ADT681
Note: For oil-free applications contact Additel.
Look us up on www.additel.com or call today (1)714-998-6899
23
Additel 680 Series
Digital Pressure Gauges
Pressure ranges to 40,000 psi (2,800 bar)
0.05%, 0.1% or 0.25%FS accuracy
Fully temperature compensated accuracy
IP67
Data logging and wireless (680W)
24
OVERVIEW
680 with data logging and wireless (optional)
We designed the 680 series digital pressure gauges with two main objectives in mind. First, to provide an affordable digital gauge to replace mechanical gauges. If you’re looking to move from dial gauges to a digital gauge, you’ll find the 680 standard version gauge to be of high quality and suited for your need in terms of price and performance. With advanced microprocessor technology and state-of-the-art silicon pressure sensors, the 680 series digital pressure gauges provide an accurate, reliable, and economic solution for a wide range of pressure applications. They are loaded with functionality and remarkably easy to use. To reach the best performance, every silicon pressure sensor is specially aged, tested and screened before assembly.
The second objective was to provide a high-precision pressure gauge capable of wireless communication and data logging. Our 680W series provides just this along with several accuracy and pressure range options to meet your need. This wireless unit is compatible with the Additel/Land Wireless software, which is available for a free download from our website. Data can be recorded standalone with the 680W and then downloaded wirelessly to Additel/Land
Wireless. For more advanced logging and data analysis, Additel/Log II Wireless is specially designed to communicate with the 680W. Each unit can store up to 140,000 readings which consist of date, time, pressure, and internal temperature. The 680 series digital pressure gauges are unmatched in performance and reliability. Best of all they are very affordable.
FEATURES
Pressure ranges to 40,000 psi (2,800 bar)
0.05%, 0.1% or 0.25% full scale accuracy
Fully temperature compensated accuracy from
14°F to 122°F (-10°C to 50°C)
Up to 13 selectable pressure units, 6 customized definition engineering units
Large, easy to read display with 5-digit resolution
Backlit display
Icon-based menu
Display flash warning when pressure exceeds
120% of FS
Stainless wetted surface construction
IP67 (submersible in 1 meter of water)
Drop-tested from 1 meter
2 AA alkaline batteries
CE R&TTE, FCC ID, IC ID Certificates
NIST traceable calibration with data(included)
SPECIFICATIONS
Models
ADT680: Regular version
ADT680W: Data logging and wireless version
Pressure Type: Gauge and Compound
Look us up on www.additel.com or call today (1)714-998-6899
Performance
Accuracy: 0.05%, 0.1% or 0.25%FS
Update Rate: 10 times/Sec ,3 times /Sec (default),
1 time /Sec ,1 time/15 Seconds
Operating Temperature: 14°F to 122°F (-10°C to 50°C)
Compensated Temperature: 14°F to 122°F (-10°C to
50°C), accuracy guaranteed
Storage Temperature: -4°F to 158°F (-20°C to 70°C)
Overload Pressure: 1.2X
Power Supply
Battery: 2 x AA alkaline (LR6) batteries
*Recommend: Duracell MX1500, EnergizerE91,
Panasonic LR6, or Duracell 15AU
Battery Life:
10 rdg/sec: 1500 hrs; 3 rdg/sec: 3000 hrs
1 rdg/sec: 6000 hrs; 1 rdg/15 sec: 12000 hrs.
Rated Power: 3.0VDC Imax=30mA Pmax=90mW
Material
Wetted Surface: All wetted surfaces are 316L Stainless
Steel with welded design for gauges ≤10,000 psi (no
O-ring, thread tape, epoxy, or sealant on any part of the sensor assembly), and copper O-ring design for gauges > 10,000 psi.
Case: PC+ABS
Protective Cover: Silicone Rubber
SPECIFICATIONS
P/N
V15
GP15
GP30
GP100
GP300
GP500
GP1K
GP3K
GP5K
GP10K
GP15K
GP20K
GP25K
GP30K
GP36K
GP40K
Display
LCD Specification: FSTN-LCD,Visual scope 36x61mm;
Full 5 digits,15.2mm High; 7 segment analog bar graph scaled from 0-100% of FS
Backlight: White
Wireless Communication (ADT680W only)
Wireless Frequency: 2.4G ISM Bands, 20 meter range
Number of wireless Channels : Chanel 1-15
Software: Wireless network demo software included
Read upto 20 gauges.
Data Logging (ADT680W only)
Storage Capacity: 140,000 readings(time, pressure, and temperature)
Storage Interval: Adjustable from 1-9999 Sec
Single-button-press data logging enabled
Compliances
Certificates:CE R&TTE, FCC ID, IC ID
Protection Level: IP67
Vibration: 5g(20-2000Hz)
Shock resistance: 100g/11ms
Others
Dimensions: 100mm x 40mm, total height:157mm
Weight: 500g
Fitting: 1/4NPT male, 1/2NPT male, 1/4BSP male,
1/2BSP male, M20×1.5 male (≤15,000 PSI)
1/4HP female or 1/4HP male(≥15,000 PSI)
*1/4HP female: Autoclave F-250-C, 9/16" - 18 UNF-2B
*1/4HP male: Autoclave M-250-C, 9/16" - 18 UNF-2A
Other connections available per request
Gauge Pressure
500
1,000
3,000
5,000
10,000
15,000
20,000
25,000
30,000
36,000
40,000
Pressure Range
(psi)
[1]
(bar)
-15
15
-1.0
1.0
30
100
300
2.0
7.0
20
1,400
1,600
2,000
2,500
2,800
35
70
200
350
700
1,000
Accuracy(FS%) Media
[3]
Burst
Pressure
0.05 (0.1, 0.25)
0.05 (0.1, 0.25)
0.05 (0.1, 0.25)
0.05 (0.1, 0.25)
0.05 (0.1, 0.25)
0.05 (0.1, 0.25)
0.05 (0.1, 0.25)
0.05 (0.1, 0.25)
0.05 (0.1, 0.25)
0.05 (0.1, 0.25)
0.05 (0.1, 0.25)
0.05 (0.1, 0.25)
0.1 (0.25)
0.1 (0.25)
0.1 (0.25)
0.1 (0.25)
G,L
G,L
G,L
G,L
G,L
G,L
G,L
G,L
G,L
G,L
G,L
G
G,L
G,L
G,L
G,L
1.5×
1.5×
1.5×
1.5×
1.1×
3×
3×
3×
3×
3×
2×
3×
3×
3×
3×
3×
Compound Pressure
[1]
P/N
Pressure Range
(psi) (bar)
Accuracy(FS%)
[2]
CP15 ±15 ±1 0.05(0.1, 0.25)
CP30 -15 to 30 -1 to 2 0.05(0.1, 0.25)
[1] Sealed gauge pressure for above 1,000 psi.
[2] FS specification applies to the span of the range.
[3] G=Gas, L=Liquid
Media
[3]
Burst
Pressure
G,L
G,L
3×
3×
Auto off:
Disabled,15, 30, 45, 60, 90, or 120 Minutes.
Filtering: Averaging (3 to 10 samples) or low-pass firstorder filter.
Engineering units: Pa, kPa, MPa, bar, mba, psi, kgf/ cm
2
, mmH
2
O, mmHg, inH extend units: inH
2
2
O, inHg, ozf/in, %, °C, °F.
O(20°C), inH O(20°C), mmH
2
O(15°C), ftH
2
2
O(60°F), mmH
O(60°F), or ftH
2
O(4°C)
2
Backlight Duration:
Not auto off,15,30,45,60 seconds optional.
Max/Min data capture: Saves Max and Min data during pressure measurement.
Key Lockout: When the gauge is in auto-storing mode, the front panel buttons will be automatically locked.
Overpressure Alarm: Display will flash over 120%FS
Battery voltage Indicator: Displays the battery life remaining. When the battery voltage is too low, the gauge will power-off automatically.
Overpressure Record:
Gauge will record max pressure data when the gauge is over pressured by 120% of FS.
Leakage test:
In leak test mode, the gauge will record beginning pressure, ending pressure, and show the difference ΔP.
Factory Reset:
Resets all settings back to factory default, except the calibration parameters.
Warranty: 1 year
ORDERING INFORMATION
Model Number
ADT680
Model:
ADT680
ADT680W
25 GP300 PSI
Range type:
PSI-range by psi
BAR-range by bar
N
Accuracy:
05-0.05% of full scale
10-0.1% of full scale
25-0.25% of full scale
Pressure range P/N:
See pressure range table
Pressure port type:
N-1/4NPT male
N2-1/2NPT male
B-1/4BSP male
B2-1/2BSP male
M-M20X1.5 male
AF-Autoclave F-250-C female
AM-Autoclave M-250-C male
Accessories included
AA battery (2 pcs); Manual; NIST traceable calibration certificate;
Rubber boot for Additel 680 gauge;
Additel/Land Wireless software for 680W (free download at www.
additel.com)
Optional Accessories
Model number Description
9503
9030
Additel/Log II Wireless real time data logging and graphical software for 680W
Spare wireless master device (USB dongle) for
ADT680W gauge.
Note: For oil-free applications contact Additel.
Look us up on www.additel.com or call today (1)714-998-6899
25
Application Note
Why Temperature Compensation Really Matters for Pressure Measurement
Have you ever wondered how much impact environmental temperature has on your pressure sensors? Nearly every pressure sensor has some sort of environmental temperature specification on its data sheet. This technical note explains the environmental temperature effects on pressure sensors, quantifying the impact, and ways to minimize the impact.
Why pressure sensors are impacted by environmental temperature changes
Much like anything else in the physical measurement world, pressure sensors are subject to changes in environmental conditions. Temperature effects tend to have the largest impact on pressure measurement accuracy. Temperature effects directly influence the pressure sensor and the circuitry used to measure the sensor. Digital pressure sensors use electronic circuits which provide an analog output proportional to the inlet pressure. There are three factors of a sensor's circuitry that are affected by environmental temperature changes: zero pressure output voltage, pressure sensitivity span and bridge resistance. Temperature-compensated sensors employee some techniques to correct for and minimize the impact of temperature changes on these factors.
To understand the environmental temperature effect on your sensor, it is helpful to first understand some common terms you may see on a pressure sensor specification sheet.
Operating Temperature Range: This is the temperature range over which the sensor can be used without causing damage.
Temperature Compensated Accuracy Range: This refers to the environmental temperature range over which the accuracy of the sensor is applicable.
Temperature Coefficient: An additional error that needs to be considered when used outside of the temperature compensated accuracy range. Many sensors are only tested and calibrated at laboratory temperatures. In this case, the temperature coefficient will need to be considered in the measurement accuracy when using the sensor outside of laboratory temperatures.
Quantifying the environmental temperature effect
So how much will the ambient temperature impact your measurement accuracy? Well, this will depend on the temperature compensated accuracy range and the temperature coefficient. To demonstrate this, let's consider three different gauges. As you can see from the specifications below (figure 1), they all have the same accuracy specification of 0.05% FS. However, as you consider the temperature compensated accuracy range and the temperature coefficient you'll see a fairly large variation between the three gauges.
Figure 1 Manufacturer 1 Manufacturer 2 Manufacturer 3
Accuracy
0.05% FS
Temperature Compensated Accuracy
Range
Temperature Coefficient
N/A
Add 0.003% FS/°C from 23°C
0.05% FS
15°C to 35°C
Add 0.003% FS/°C: -10°C to
15°C, 35°C to 50°C
0.05% FS
-10°C to 50°C
N/A
The graph below shows the total specified accuracy when considering the temperature effects on the pressure gauges. As you can see in one case here, the lack of temperature compensation and inclusion of the temperature coefficient specification more than triple the 0.05% FS accuracy specification
26
Look us up on www.additel.com or call today (1)714-998-6899
Temperature compensation test results
To further show temperature compensation has real effect, we placed a non-temperature compensated pressure gauge in a temperature chamber and pressure tested it from 0 to 580 psi (0 to 40 bar) and over the environmental temperature range of 0°C to 40°C. We then performed the same test on a temperature compensated gauge. As you may expect—the higher the pressure, the larger the impact from the environmental temperature. Below is a chart comparing the non-temperature compensated gauge with the temperature compensated gauge.
Minimizing environmental temperature error
The temperature effect on a pressure sensor will be negligible when used at the same laboratory temperature in which it was calibrated. This, however, is often not practical for your measurements.
With sensor technology advances, we have found a variety of ways to minimize the temperature effect on pressure sensors and with confidence define a large temperature compensated accuracy range. First, regularly zero your digital pressure gauges. By zeroing the pressure gauge, you are aligning the zero pressure output voltage to the current environmental conditions. You should only zero the pressure gauge when you do not have any inlet pressure on the gauge.
Because each sensor is unique and performs differently due to environmental temperature changes, at Additel, we pressure test every sensor in a thermal chamber at different temperatures so we understand its pressure performance relative to environmental changes. Each sensor contains a temperature-compensated circuit which we load coefficients representing the temperature testing of the gauge. This allows for you to confidently use our sensors over the range -10°C to 50°C without having to add a temperature coefficient error to the accuracy.
Look us up on www.additel.com or call today (1)714-998-6899
27
Multifunction Process Calibrators
Selection Guide
Models
Additel 209 Loop
Calibrator
Additel 210
Loop Calibrator
Additel 220
Multifunction Loop
Calibrator
Measure
Voltage(mV)
Voltage(V)
Current (mA)
Resistance(ohm)
Frequency(Hz)
Pulse
Limit Switch
Pressure
Source / Simulate
Voltage(mV)
Voltage(V)
Current (mA)
Resistance(ohm)
Frequency(Hz)
Pulse
DC 24 V
Record
Scaling
Min/Max/Avg/Tare
Hold
As found/ As left
On-demand logging
Upload data to PC
Features
24V loop supply
Ramp/ Step
Simulate Transmitter
RTD
Thermocouple
HART communication
Documenting
Warranty
NIST traceable calibration
See Page
0 to 30 V
0 to 24 mA
0 to 24 mA
3 years
•
P27
0 to 30 V
0 to 24 mA
0 to 24 mA
3 years
•
P27
±300 mV
±60 V
±30 mA
0 to 2,000 Ω
3 to 24V
-10 to 200 mV
0 to 12 V
0 to 22 mA
•
•
•
•
•
•
•
•
•
[4]
3 years
•
P29
•
•
•
•
•
•
11 types
[2]
13 types
[3]
•
3 years
•
P31
Additel 221A
Multifunction
Temperature
Calibrator
Additel 222A
Multifunction Process
Calibrator
Additel 223A
Documenting Process
Calibrator
±75 mV
±30 V
±30 mA
0 to 4,000 Ω
1 to 50,000 Hz
0 to 999,999
3 to 24V
-10 to 75 mV
0 to 12 V
0 to 22 mA
1 to 4,000 Ω
0 to 50,000 Hz
0 to 999,999
•
•
±75 mV
±30 V
±30 mA
0 to 4,000 Ω
1 to 50,000 Hz
0 to 999,999
3 to 24V
•
[1]
-10 to 75 mV
0 to 12 V
0 to 22 mA
1 to 4,000 Ω
0 to 50,000 Hz
0 to 999,999
•
•
±75 mV
±30 V
±30 mA
0 to 4,000 Ω
1 to 50,000 Hz
0 to 999,999
3 to 24V
•
[1]
-10 to 75 mV
0 to 12 V
0 to 22 mA
1 to 4,000 Ω
0 to 50,000 Hz
0 to 999,999
•
•
•
•
•
•
•
•
11 types
[2]
13 types
[3]
•
3 years
•
P31
•
•
•
•
•
•
11 types
[2]
13 types
[3]
•
•
3 years
•
P31
[1] Additel 160A External Pressure Module required
[2] RTD Includes Pt10(385), Pt100(385), Pt100(3916), Pt100(3926), Pt500(385), Pt1000(385),
Cu10(427), Cu50(428), Cu100(428), Ni100(617), Ni120(672),Ni1000 and customized
[3] Thermocouple Includes S, R, B, K, N, E, J, T, C, D, G, L, U
[4] Built-in 250Ω resistor for HART communications.
28
Look us up on www.additel.com or call today (1)714-998-6899
Additel 209 and 210 Series Loop Calibrator
Accuracy to 0.01% of reading
Small and rugged handheld design
Measure, source, or simulate loop current
Measure DC volts
Simultaneously mA and % span display
Switch functionality
Selectable ramp and step functions
Easy to read display and user interface
HART 250Ω resistor in series with 24V loop
OVERVIEW
The new Additel 209 and 210 loop calibrator series combine ease of use and functionality, making them the ideal tools to troubleshoot your process loop.
The ADT209 has an accuracy of 0.03% of reading whereas the ADT210 holds an accuracy of 0.01% of reading. If you want to source, simulate or simply measure, the Additel Loop calibrator series will fit your need. The
ADT209 and ADT210 allow for measurement of current, voltage and a switch.
You can also simulate or source mA or a process transmitter. With a push of a button, you can switch to zero and span values, auto ramp, and auto step throughout the range. Each loop calibrator has a large, easy to read screen which simultaneously displays the measurement with the % of span.
ELECTRICAL MEASURE SPECIFICATIONS
Range Resolution ADT209 Accuracy
Voltage DC
1
0 to 30 V 1 mV 0.03%RD + 2mV
Current DC
2
0 to 24 mA 1 μA 0.03%RD + 2μA
Switch test
Input resistance more than 500 MΩ
Trigger level: low level <0.3V; high level: >2V
[1] 1MΩ input resistance
[2] Loop transmitter current measure: 700Ω maximum
ADT210 Accuracy
0.01%RD + 2mV
0.01%RD + 2μA
ELECTRICAL SOURCE SPECIFICATIONS
Range Resolution ADT209 Accuracy ADT210 Accuracy
Current DC
0 to 24 mA 1 μA
Source mode
700Ω/20 mA maximum
Sink mode
0.03%RD + 2μA 0.01%RD + 2μA
External loop voltage nominal 24V, maximum 30V, minimum 12V
Look us up on www.additel.com or call today (1)714-998-6899
29
GENERAL SPECIFICATIONS
Voltage limit
Measurement Functions
Display
Loop power
Over-voltage protection
Overload current protection
Storage temperature
Working Environment
Working Altitude
Vibration/shock
Power
Battery life (typical)
Size (LxWxH)
Weight
Calibration Certification
Compliance Certification
Warranty
30V between terminals or between terminals and ground
Auto step, auto ramp, span step
VA LCD display. 2.04 x 2.04 in (52 x 52 mm)
24V
30V DC (240V AC)
33 mA DC
-20°C to 70°C
-10 to 50°C, 95%RH
<3,000 m
Random 2G 5 to 500Hz
1 meter drop
One 9V alkaline battery (ANSI/NEDA 1604A or IEC)
DC9V optional adapter available
Output mode: 18 hours (12 mA/500Ω)
Measure mode: 50 hours
163 x 83 x 41 mm
350 g
NIST-traceable certificate of calibration with data
ADT209: CSA, CE, DNV
ADT210: CSA, CE, DNV
3 years
ORDERING INFORMATION
Model Number
ADT209
ADT210
Accessories included
Test lead set
Alligator clips
User manual
9V Alkaline battery
1 set
2 pcs
1 pc
1 pc
Optional Accessories
9812 110V/220V external power adapter (DC 9V)
30
Look us up on www.additel.com or call today (1)714-998-6899
Additel 220
Multifunction Loop Calibrator
Measure and source loop current, mV, and V
Measure and source simultaneously
Loop Continuity Test capability
24V loop supply with simultaneous current measurement
3 year warranty
OVERVIEW
The 220 is a highly integrated loop calibrator featuring several patented technologies. The calibrator is an ultra-compact, rugged, and best of all, easy to use hand-held device that will source, simulate and measure loop current, mV/V, Loop
Continuity Test, and also perform switch testing. Its smart phone-like menu and interface makes it simple and easy to use. The 220 is ideal for calibrating, maintaining, and troubleshooting various loop devices in the field.
FEATURES
Measuring and sourcing loop current, mV and V
Measures loop current up to 30mA with 0.1μA resolution
Measures voltage signals up to 60 V, and mV signals up to 300 mV
Sources/sink loop current, mV and V
24V loop power supply with simultaneous current measurement
Simultaneous dual reading capability
Capture switch
Data statistics and analysis
Display max, min, peak-to-peak, average, and percentage simultaneously
Convert data to a real physical value through re-scaling function
On-demand logging
High-capacity storage with up to twenty thousand records
On-line view, index, analyze, auto-curve, and list the data
Various sources and converting mode
Support linear, flow, valve, and 25% stepping source
Auto-source of ramping and stepping
Gauge span examination
"As Cal" on-site calibration tools
Four on-site calibration tools preset: loop indicator, sensor/transmitter, signal isolator/converter, and limit alarm/switch
Support 2W transmitter connection
Multi lingual interface
English,Simplified Chinese
Convenient tools
Calculator, thermocouple converter, HOLD screen lock
Display rate
4 readings/second
Easy to use
Smartphone-like menu and interface make the operation simpler and easier
Ultra-compact, size 3.9" x 7.6" x 2.0" (100mm x
192mm x 52mm), and weight 1.6 lb (0.7 kg)
One hand operation
Snapshot
Save and manage up to 100 snapshots
Display
3.5 inch TFT color screen
4, 5, or 6 digits adjustable display
Rugged
Rugged design for harsh environments.
Passed a 1-meter drop test
Three years warranty for the 220, and one year for the battery pack
Misuse protection and Electrical isolation
Up to 30V voltage on any two sockets and up to
1A current on current sockets will not damage the calibrator. The calibrator will return to normal condition as soon as the voltage or current is removed.
Measuring, sourcing and loop power circuits are electrically isolated each other.
Rechargeable battery
Rechargeable Li-ion battery for 15 hours uninterrupted use.
Battery life will be reduced when 24V is applied.
The rechargeable battery is replaceable.
NIST Traceable Calibration with data
Firmware upgrade
Support firmware upgrade when available
Warranty: 3 years
Look us up on www.additel.com or call today (1)714-998-6899
31
Additel 220
Multifunction Loop Calibrator
APPLICATIONS
The 220 loop calibrator is a process tool for measuring, sourcing and simulating mA, mV and V, captures switch values and provides 24V loop power. It is a high performance solution for calibration, repair and maintenance of various loops devices, Loop Continuity Test, and switch capture.
32
SPECIFICATIONS
Electrical Specifications
Measurement Accuracy
Range
-300.000 to 300.000 mV
Resolution
1μV
Voltage DC
-60.0000 to 60.0000 V 0.1mV
Current DC
-30.0000 to 30.0000 mA 0.1μA
Loop
Continuity
0 to 2000.0 ohm 0.1Ω
Accuracy
0.01%RD+15μV
0.01%RD+3mV
0.01%RD+1.5μA
0.02%RD+0.2Ω
Source Accuracy
-10.00 to 200.00 mV
Voltage DC
Current DC
0 to 12.000 V
0 to 22.000 mA
DC24V
N/A
General Specifications
Environmental Specifications
Operating
Temperature
Storage Temperature
Humidity
0.01mV
1mV
1μA
N/A
-10°C to 50°C
-20°C to 60°C
<90%, non-condensing
0.02%RD+10.5μV
0.02%RD+0.6mV
0.02%RD+1.1μA
0.5V
Safety Specifications
European
Compliance
CE Mark
Mechanical Specifications
Display
Electrical Connection
RS232 Interface
Size
Weight
Power Supply
Battery
Battery Life
Battery Charge
3.5 inch TFT color screen
Ø4mm sockets and flat mini-jack thermocouple socket
Standard RS232-DB9 socket
3.9" x 7.6" x 2.0" (100mm x 192mm x 52mm)
1.6 lb (0.7 kg)
Polymer Li-ion rechargeable battery,or 10V DC adaptor
Rechargeable Li-ion battery (included)
15 hours uninterrupted use
Battery life will be reduced when 24V is applied
110V/220V external power adapter (included)
Look us up on www.additel.com or call today (1)714-998-6899
ORDERING INFORMATION
Model Number
ADT220
Accessories (included)
110V/220V external power adapter
Chargeable Li-ion battery
Test leads
Short circuit cable
Manual
NIST traceable calibration certificate
1 pc
1 pc
2 sets(4 pcs)
1 sets(2 pcs)
1 pc
1 pc
* Additel/Land software could be downloaded for free at www.additel.com
Optional Accessories
Model number
9050
9712
9816
9906
Description
USB to RS232 (DB-9 Male) Adapter
Spare chargeable Li-ion battery for multifunction calibrator
110V/220V external power adapter
Carrying case for multifunction calibrator
Additel 221A, 222A & 223A
Multifiction Documenting Process
Calibrators
Sourcing, simulating and measuring pressure, temperature and electrical signals
Smartphone-like menu and interface make the operation simple
HART Communication capability (223A)
The internal cold junction compensation sensor can be re-calibrated at ice point by user
Ultra-compact, 3.9" x 7.6" x 2.0", and 1.6 lb (0.7 kg)
OVERVIEW
This series of highly integrated multifunction calibrators feature several patented technologies. These are an ultracompact, rugged, and easy to use hand-held device for sourcing, simulating and measuring pressure, temperature, and electrical signals. Their smartphone-like menu and interface make the operation simple. Automation and documentation capabilities make the these calibrators a turnkey solution.
Additel 221A
The Additel 221A is very unique to the multifunction temperature calibrator market. Not only does it provide you with the ability to source, simulate and measure temperature and electrical functions but it also incorporates full documenting capability and many other solutions other products do not provide. As a standalone device, you can create tasks, run tests and store the results. With the use of Additel/Land Software or Additel/Cal software, all saved tasks and data can be downloaded and managed. With it's unique internal could junction compensation sensor, cold junction compensation is very simple and easy.
Additel 222A
The Additel 222A Multifunction Process Calibrator takes all the functionality of the 221A and adds the ability to measure and source pressure using the ADT160A Intelligent Pressure Modules. With calibration characteristics programmed directly into the ADT160A pressure modules you can simply connect it to the 222A and it will automatically recognize and display the module as the source or measure pressure. For ultimate convenience, one 222A allows for modules to be
"hot swapped" with a simple connection at the top of the module.
Additel 223A
The 223A has all the capability of the 221A and 222A and HART Communication in one small, easy-to-use package.
The 223A has a full HART library that allows for the reading of HART-smart devices and also the capability to write to devices. Combined with full task automation and documentation, the 223A is an ideal tool to accomplish many of your important tasks.
FEATURES
Sourcing, simulating and measuring temperature and electrical signals
Sources and measures mV, mA, ohms, RTDs, thermocouples, frequency, and pulses
Simulates and measures 13 thermocouples and 11
RTDs to calibrate transmitters
Measures and sources pressure using Additel 160A series Intelligent Digital Pressure Modules from -15 psi to 10,000 psi (-1 bar to 700 bar)
24V loop power supply
Simultaneous dual reading capability
Automatic switch test
Supports square root transmitter
Pulse frequency output for the calibration of flow totalizer
Easy to use
Smartphone-like menu and interface make the operation simpler and easier
Ultra-compact, size 3.9" x 7.6" x 2.0" (100mm x 192mm x 52mm), and weight 1.6 lb (0.7 kg)
One hand operation
Calibrated cold junction compensation (Patented)
Cold junction equivalent block in the calibrator
A calibrated PRT element with flexible leads is installed in the equivalent block for thermocouple cold junction compensation
This PRT element can be pulled out from the calibrator and re-calibrated and corrected at ice point by users
Documenting and automated procedure capability
Manage the information of the device under test.
Set up automated calibration procedures, and 223A performs the test, calculates the errors, displays and/ or stores the results in the memory, and highlights the out-of-tolerance points.
As-found and As-left functions allow recording and documenting results for quality control.
Download tasks and upload the results.
Snapshots allow you to capture and save work.
NIST Traceble Cable with data
Look us up on www.additel.com or call today (1)714-998-6899
33
34
Built-in temperature readout
CVD coefficients of a calibrated PRT can be input into the calibrator for accurate temperature measurement.
Multi lingual interface
English, German, French, Italian, Spanish, Portuguese,
Simplified Chinese
(Traditional Chinese, Japanese and Russian are available per request)
Build-in unit conversion tool
Build-in converters for pressure units, temperature units, temperature vs. resistance (RTDs), and temperature vs millivolt (thermocouples)
Warranty:3 years
SPECIFICATIONS
Electrical Specifications
Measurement Accuracy
Range Resolution Accuracy
Voltage DC
±75.0000 mV
±30.0000 V
Current DC
± 30.0000 mA
Two-wire
0 to 400.000 Ω
Three-wire 0 to 400.000 Ω
0.1μV
0.1 mV
0.1μA
1mΩ
Four-wire
0 to 400.000 Ω
Two-wire
0 to 4000.00 Ω
1mΩ
1mΩ
Resistance
Three-wire 0 to 4000.00 Ω
Four-wire
Frequency
0 to 4000.00 Ω
10mΩ
10mΩ
10mΩ
1 to 50000.0 Hz 0.1Hz
Pulse
0 to 999999 1
Limit Switch
0.01%RD + 3.75 μV
0.01%RD + 1.5 mV
0.01%RD + 1.5 μA
0.02%RD + 0.02 Ω
0.02%RD + 0.02 Ω
0.01%RD + 0.02 Ω
0.02%RD + 0.2 Ω
0.02%RD + 0.2 Ω
0.01%RD + 0.2 Ω
0.005%RD + 1 Hz
N/A
For the contact with potential, the voltage within the range 3V to 24V.
Source Accuracy
Voltage DC
Current DC
Resistance
Frequency
Pulse
DC24V
-10.000 to 75.000mV
0 to 12.0000 V
0 to 22.000 mA
1 to 400.00 Ω
1 to 4000.0 Ω
0 to 50000.0 Hz
0 to 999999
N/A
1μV
0.1mV
1μA
10mΩ
100mΩ
0.1Hz
1
N/A
0.02%RD + 4.25 μV
0.02%RD + 0.6 mV
0.02%RD + 1.1 μA
0.02%RD + 0.02 Ω
0.03%RD + 0.4 Ω
0.005%RD + 1 Hz
N/A
0.5V
General Specifications
Environmental Specifications
Operating Temperature
Storage Temperature
Humidity
-10°C to 50°C
-20°C to 60°C
<90%, non-condensing
Safety Specifications
European Compliance
CE Mark
Mechanical Specifications
Display
3.5 inch TFT color screen
Electrical Connection Ø4mm sockets and flat mini-jack thermocouple socket
RS232 Interface
Size
Standard RS232-DB9 socket
3.9" x 7.6" x 2.0" (100mm x 192mm x 52mm)
Weight
1.6 lb (0.7 kg)
Power Supply
Battery
Polymer Li-ion rechargeable battery,or 10V DC adaptor
Rechargeable Li-ion battery (included)
Battery Life
15 hours uninterrupted use
Battery life will be reduced when 24V is applied
Battery Charge
110V/220V external power adapter (included)
Pressure Specification(222A & 223A)
The 160A series Intelligent Digital Pressure Modules are available for gauge, vacuum and absolute pressure from -15 psi to 10,000 psi (-1 bar to
700 bar). Accuracy from 0.02% FS includes operation over 14°F to 122°F
(-10°C to 50°C), one year stability and calibration uncertainty. For detail specification refer to pressure modules datasheet.
Look us up on www.additel.com or call today (1)714-998-6899
HART Communication capability (223A)
Support HART
®
instrumentation
Display
3.5 inch TFT color screen
Misuse protection
Up to 30V voltage on any two sockets and up to
1A current on current sockets will not damage the calibrator. The calibrator will return to normal condition as soon as the voltage or current is removed.
Rechargeable battery
Rechargeable Li-ion battery for 15 hours uninterrupted use.
Battery life will be reduced when 24V is applied.
The rechargeable battery is replaceable.
Temperature Specification
Thermocouple Measurement and Source Accuracy
Measure and Simulate
Standard Temperature Range ( o
C)
S
R
B
K
N
E
J
T
C
D
G
L
U
IEC 584
IEC 584
IEC 584 0 to 1820
IEC 584
IEC 584
IEC 584
IEC 584
IEC 584
ASTM
E988
ASTM
E988
ASTM
E1751
-50 to
1768
-50 to
1768
-270 to
1372
-270 to
1300
-270 to
1000
-270 to
1200
-270 to
400
0 to 2315
0 to 2320
0 to 2315
-100 to 1300
-250 to -200
-200 to -100
-100 to 0
0 to 700
700 to 1000
-210 to -100
-100 to 1200
-250 to -200
-200 to 0
0 to 400
0 to 1000
1000 to 1800
1800 to 2315
0 to 100
100 to 1100
1100 to 2000
-50 to400
400 to 1000
1000 to1768
-50 to 200
200 to 500
500 to 1768
50 to 450
450 to 800
800 to 1820
-250 to -200
-200 to -100
-100 to 600
600 to 1372
-250 to -200
-200 to -100
2000 to 2320
0 to 200
200 to 400
400 to 1400
1400 to 2315
-200 to -100
-100 to 400
400 to 900
-200 to 0
0 to 600
Accuracy ( o
C)
Measure Source
0.2
0.5
0.7
1.0
0.5
0.4
0.6
0.2
0.3
0.3
0.8
0.4
0.4
0.6
0.3
0.2
0.2
0.2
0.2
0.2
0.4
0.2
0.9
2.4
0.5
0.4
0.7
0.6
1.0
0.4
0.3
0.4
1.5
0.5
1.0
0.6
0.7
1.4
0.6
0.6
3.8
0.9
0.2
0.5
0.9
1.4
0.5
0.5
0.9
0.4
0.3
0.4
0.9
0.4
0.5
0.7
0.3
0.2
0.3
0.3
0.2
0.3
0.4
0.3
1.3
2.4
0.5
0.5
1.0
0.7
1.1
0.5
0.3
0.5
1.6
0.6
1.1
0.6
0.8
1.4
0.6
0.7
3.8
0.9
SPECIFICATIONS
Measurement Accuracy
Measure and Simulate
Pt10(385)
Pt100(385)
Pt100(3916)
Pt100(3926)
Pt500(385)
Pt1000(385)
Cu10(427)
Cu50(428)
Cu100(428)
Ni120(672)
Ni100(618)
Standard
IEC 751
IEC 751
JIS 1604
IEC 751
IEC 751
-200 to 850
-200 to 850
-200 to 850
Minco Application Aid #18 -200 to 850
-200 to 850
-200 to 850
Minco Application Aid #18 -100 to 260
GOST 6651-94 -50 to 150
GOST 6651-94
Edison curve #7
DIN 43760
-50 to 150
-100 to 260
-100 to 260
Temperature Range (°C)
-100 to 200
200 to 600
600 to 850
-100 to 200
200 to 600
600 to 850
-100 to 200
200 to 600
600 to 850
-100 to 200
200 to 600
600 to 850
-100 to 200
200 to 600
600 to 850
-100 to 200
200 to 600
600 to 850
-100 to 260
-50 to 150
-50 to 150
-100 to 260
-100 to 260
ORDERING INFORMATION
Model Number
ADT221A
ADT222A
ADT223A
Accessories (included)
110V/220V external power adapter
Chargeable Li-ion battery
Test leads
Short circuit cable
9060 Pressure module connection cable
(only for 222A & 223A)
Manual
1 pc
1 pc
3 sets(6 pcs)
1 sets(2 pcs)
1 pc
1 pc
NIST traceable calibration certificate 1 pc
* Additel/Land software can be downloaded for free at www.additel.com
Measure (2W/3W)
0.65
0.82
0.96
0.15
0.26
0.34
0.26
0.33
0.20
0.32
0.15
0.26
0.33
0.15
0.40
0.1
0.2
0.27
Accuracy (°C)
Measure (4W)
0.60
0.72
0.82
0.1
0.16
0.20
0.16
0.20
0.16
0.22
0.1
0.16
0.20
0.1
0.27
0.05
0.10
0.14
0.61
0.56
0.17
0.13
0.12
0.07
0.08
0.09
0.05
0.06
Optional Accessories
Model number
9510
Description
ADT160A
(only for 222A & 223A) Intelligent Digital Pressure Modules
9060
(only for 222A & 223A) Pressure module connection cable
9050 USB to RS232 (DB-9 Male) Adapter
9080
9712
9816
9906
Cable kit (including TC plug, compensation cable, S,R,B,K,J,T,E,N)
Spare chargeable Li-ion battery for multifunction calibrator
110V/220V external power adapter for ADT22X and ADT672 calibrator
Carrying case for multifunction calibrator
Additel/Cal Task management software for multifunction calibrator
0.26
0.33
0.36
0.54
0.15
0.26
0.33
0.15
Source
0.65
0.82
0.96
0.15
0.26
0.34
0.67
0.25
0.42
0.54
0.61
0.17
0.12
0.07
0.08
Look us up on www.additel.com or call today (1)714-998-6899
35
Additel 160A
Intelligent Digital Pressure Modules
Precision accuracy to 0.005%RD + 0.005%FS
Pressure measurement accuracy of 0.02% FS
Pressure ranges to 40,000 psi (2,100 bar)
Fully temperature compensated accuracy
36
Gauge pressure Differential pressure
OVERVIEW
With advanced microprocessor technology and state-of-the-art silicon pressure sensors, the Additel 160A series
Intelligent Digital Pressure Module (IDPM) provides an accurate, reliable, and economic solution for wide range of pressure applications. It is loaded with functionality and remarkably easy to use. In order to reach the best performance, every silicon pressure sensor in the module has been specially aged, tested and screened before assembly. Designed as external pressure module for Additel 761 automated pressure calibrator and Additel 222A,
Additel 223A and Additel 780 calibrators, the Additel 160A IDPM is unmatched in performance and reliability.
FEATURES
Precision sensor measurement accuracy to 0.005%RD
+ 0.005%FS
Gauge pressure measurement accuracy of 0.02% FS
Absolute Pressure measurement accuracy of 0.1% FS
Pressure ranges to 40,000 psi (2,800 bar)
Advanced temperature compensation
NIST traceable calibration and data included
SPECIFICATIONS
Gauge types
Gauge pressure Differential Pressure
Compound pressure Absolute pressure
Pressure Ranges and Accuracy
Differential Pressure
P/N
DP1
DP2
Pressure Range
[1]
(inH
2
0) (mbar)
±1
±2
±2.5
±5.0
DP5
DP10
DP20
±5
±10
±20
DP30
DP50
±30
±50
DP150 ±150
DP300 ±300
±10
±25
±50
±75
±160
±350
±700
G
G
G
G
G
G
G
G
G
0.05
[2]
0.05
[2]
0.05
[2]
0.05
[2]
0.05
0.05
0.05
0.02
0.02
100×
100×
50×
20×
20×
20×
3×
3×
3×
Burst
Pressure
Static
Pressure
Range
±10 psi
±10 psi
±10 psi
±10 psi
±10 psi
±10 psi
±10 psi
50 psi
50 psi
[1] FS specification applies to the span of the range. Accuracy includes 1 year stability.
[2] 0.05%FS accuracy (incl 6 months stability). One year accuracy is 0.05%FS calibration accuracy combined with 0.05%FS one year stability.
Look us up on www.additel.com or call today (1)714-998-6899
Gauge Pressure
[1]
P/N
V15
GP2
GP5
GP10
GP15
GP30
GP50
GP100
GP300
GP500
GP600
GP1K
GP2K
GP3K
GP5K
GP10K 10,000
GP15K 15,000
GP20K 20,000
GP25K 25,000
GP30K 30,000
GP36K 36,000
GP40K 40,000
500
600
1,000
2,000
3,000
5,000
15
30
50
100
300
Pressure Range
(psi) (bar)
-15 -1.0
2
5
10
0.16
0.35
0.7
1.0
2.0
3.5
7.0
20
700
1,000
1,400
1,600
2,000
2,500
2,800
140
200
350
35
40
70
Media
[2]
Accuracy(%FS)
G , L
G , L
G , L
G , L
G , L
G , L
G , L
G , L
G , L
G , L
G , L
G , L
G , L
G
G
G , L
G , L
G , L
G
G
G
G
Note:
[1]. Sealed gauge pressure for above 1000 psi
[2]. G=Gas, L=Liquid
0.02
0.05
0.05
0.1
0.1
0.1
0.1
0.02
0.02
0.02
0.02
0.02
0.02
0.02
0.02
0.02
0.02
0.02
0.02
0.05
0.05
0.02
Burst
Pressure
2×
2x
1.5x
1.5x
1.5x
1.5x
1.1x
3×
3×
3×
3×
3×
3×
3×
3×
3×
3×
3×
3×
3×
3×
3×
SPECIFICATIONS
Precision Quartz Sensors
[1]
- Absolute Pressure
P/N psia
Pressure Range bar.a
AP45Q
AP100Q
AP400Q
AP500Q
AP1KQ
AP2KQ
0 to 45
0 to 100
0 to 400
0 to 500
0 to 1,000
0 to 2,000
3.0
7.0
28
35
70
140
AP3KQ
0 to 3,000 200
[1] Contact Additel for other range options.
Additel 780 with ADT160A Pressure Module
Media
G
G
G
G
G
G
G
Accuracy
0.005% rdg + 0.005% FS
0.005% rdg + 0.005% FS
0.005% rdg + 0.005% FS
0.005% rdg + 0.005% FS
0.005% rdg + 0.005% FS
0.005% rdg + 0.005% FS
0.005% rdg + 0.005% FS
CP600
CP1K
CP2K
CP3K
CP5K
CP10K
CP10
CP15
CP30
CP50
CP100
CP300
CP500
Compound Pressure
P/N psig
Pressure Range bar.g
±10
±15
-15 to 30
-15 to 50
-15 to 100
-15 to 300
-15 to 500
-15 to 600
-15 to 1,000
-15 to 2000
-15 to 3,000
-15 to 5000
-15 to 10,000
±0.7
±1.0
-1 to 2.0
-1 to 3.5
-1 to 7.0
-1 to 20
-1 to 35
-1 to 40
-1 to 70
-1 to 140
-1 to 200
-1 to 350
-1 to 700
Media
G,L
G,L
G,L
G,L
G
G
G
G
G,L
G,L
G,L
G,L
G,L
Accuracy
0.02% FS
0.02% FS
0.02% FS
0.02% FS
0.02% FS
0.02% FS
0.02% FS
0.02% FS
0.02% FS
0.02% FS
0.02% FS
0.02% FS
0.02% FS
Burst
Pressure Rating
Over Pressure
3x
3x
3x
3x
3x
3x
3x
1.2x
1.2x
1.2x
1.03x
1.1x
1.1x
1.1x
Burst
Pressure Rating
Over Pressure
3x
3x
3x
3x
3x
3x
3x
3x
3x
3x
3x
3x
2x
1.2x
1.2x
1.2x
1.2x
1.2x
1.2x
1.2x
1.2x
1.2x
1.2x
1.2x
1.2x
1.2x
Look us up on www.additel.com or call today (1)714-998-6899
37
AP5
AP10
AP15
AP30
AP50
AP100
AP300
AP500
AP1K
AP3K
AP5K
Absolute Pressure
P/N
500
1,000
3,000
5,000
Pressure Range
(psi) (bar)
5 0.35
10
15
30
50
100
300
0.7
1.0
2.0
3.5
7.0
20
35
70
200
350
Media Accuracy(%FS)
Burst
Pressure
G
G
G , L
G , L
G
G
G
G , L
G , L
G , L
G , L
0.1
0.1
0.1
0.1
0.1
0.05 (0.1)
0.05 (0.1)
0.05 (0.1)
0.05 (0.1)
0.05 (0.1)
0.05 (0.1)
3×
3×
3×
3×
3×
3×
3×
3×
3×
3×
3×
ORDERING INFORMATION
Model Number
ADT160A
Model
02
Accuracy:
01-0.005%rdg+0.005% of full scale
02-0.02% of full scale
05-0.05% of full scale
10-0.1% of full scale
Pressure range P/N:
See pressure range table
GP300 PSI
Range type:
PSI - range by psi
BAR - range by bar
Pressure port type:
N - 1/4NPT male
N2 - 1/2NPT male
B - 1/4BSP male
B2 - 1/2BSP male
M - M20 X 1.5 male
N
Additel 223A with ADT160A Pressure Module
SPECIFICATIONS
Temperature compensation
Operating temperature
Storage temperature
Relative humidity
Pressure connections
(for external use only)
Enclosure
(for external use only)
Dimensions (Dia x H)
Weight
Warranty
CPXXX
Standard Accuracy
DPXXX GPXXX
-10°C to 50°C (14°F to 122°F)
-10°C to 50°C (14°F to 122°F)
-20°C to 70°C (-4°F to 158°F)
95% RH
1/4NPT, 1/2NPT, 1/4BSP, 1/2BPS, M20x15
SS enclosure
33 mm x 123 mm (1.3” x 4.84”)
0.4 kg (0.99 lb)
1 Year
Accessories included
NIST Traceable Calibration Certificate
Optional Accessories
Model number
Description
9060 Pressure module connection cable
Picture
Precision Accuracy
AP3KQ AP1KQ AP100Q
0°C to 50°C (32°F to 122°F)
0°C to 50°C (32°F to 122°F)
-20°C to 70°C (-4°F to 158°F)
95% RH
1/4NPT, 1/2NPT, 1/4BSP, 1/2BSP, M20x15
SS enclosure
44 mm x 220mm (1.7” x 8.7”)
0.8 kg (1.8 lb)
1 Year
60 mm x 190 mm (2.4” x7.5”)
1.2 kg (2.6 lb)
1 Year
38
Look us up on www.additel.com or call today (1)714-998-6899
Pressure Test/Calibration Pumps
Selection Guide
Model Photo Type Range in psi
Additel 901 Pneumatic (-6 to 6) psi
Range in bar
(-0.4 to 0.4) bar
Media
Adjustment
Resolution
Weight
See
Page
Air 0.001 mbar 3.5 lb P40
Additel 912
Additel 914
Additel 916
Additel 917
Pneumatic (-14 to 60) psi (-0.95 to 4) bar Air 0.001 mbar 6.2 lb P41
Pneumatic (-14 to 375) psi (-0.95 to 25) bar Air 0.1 mbar 3.3 lb P42
Pneumatic (-14 to 600) psi (-0.95 to 40) bar Air 0.1 mbar 5.9 lb P43
Pneumatic (-14 to 1,000) psi (-0.95 to 70) bar Air 0.1 mbar 5.7 lb P44
HOT
Additel 918
Additel 919A
Pneumatic (-14 to 1,500) psi (-0.95 to 100) bar Air 0.1 mbar 5.7 lb P45
Pneumatic (-14 to 2,000) psi (-0.95 to 140) bar Air 0.1 mbar 14.3 lb P46
HOT
Additel 920
Additel 925
Additel 927
Additel 928
Additel 936
Additel 937
Additel 938
Pneumatic (-14 to 3,000) psi (-0.95 to 200) bar Air 0.1 mbar 14.3 lb P48
Hydraulic
Hydraulic
Hydraulic
Hydraulic
Hydraulic
Hydraulic
(-12.5 to 6,000) psi (-0.85 to 400) bar
Oil/
Water
[1]
1 mbar
(-12.5 to 10,000) psi
(-0.85 to 700) bar
Oil/
Water
[1]
1 mbar
(0 to 15,000) psi
(0 to 1,000) bar
Oil/
Water
[1]
1 mbar
(-12.5 to 15,000) psi
(-0.85 to 1,000) bar
Oil
(-12.5 to 15,000) psi
(-0.85 to 1,000) bar
Oil
[2]
1 mbar
1 mbar
(-12.5 to 15,000) psi
(-0.85 to 1,000) bar
Water 1 mbar
3.7 lb
7 lb
8.6 lb
35.2 lb
P51
35.2 lb P54
35.2 lb
P49
P52
P53
P55
Hydraulic (0 to 15,000) psi (0 to 1,000) bar Oil 1 mbar 28.7 lb P56
NEW
Additel 946
HOT
Additel 949 Hydraulic
(-12.5 to 40,000) psi
(-0.85 to 2,800) bar
Oil 1 mbar 35.2 lb P57
NEW
Additel 959 Hydraulic (0 to 40,000) psi (0 to 2,800) bar Oil 1 mbar 28.7 lb P58
[1] Oil is default media liquid. Pump with water as media to be ordered
specially.
[2] Oil, compatible to phosphoric acid fluid or skydrol oil.
Look us up on www.additel.com or call today (1)714-998-6899
39
40
Additel 901
Low Pressure Test Pump
Generate 6 psi (0.4 bar) vacuum to 6 psi (0.4 bar) pressure
Portable, only 3.5 lb
Great stability and high resolution
Minimal maintenance
Hand-tight quick connectors
OVERVIEW
The 901 Low Pressure Test Pump is a hand operated pressure pump designed to generate pressures from -6 psi (-0.4 bar) to 6 psi (0.4 bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up to 0.1 Pa (0.001 mbar). The 901 is a very stable low pressure calibrator. It makes use of an isothermal bellows chamber which is designed for reducing the possible effects of environmental temperature change. Most pumps make use of a check valve (non-returning valve) and are not well insulated which will cause large fluctuations in pressure with a change in ambient temperature or when the unit is touched. The 901 does not use a check valve and is remarkably stable. Two hand-tight connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 901 is an ideal comparison test pump for low pressure applications.
FEATURES
Portable: Only 3.5 lb (1.6 kg)
Adjustment Resolution
0.1Pa (0.001 mbar); Specially designed screw press for fine pressure adjustment.
Great Stability
Isothermal chamber: the pressure chamber is insulated to reduce the influence from environmental temperature changes.
Specially designed bellows minimize leakage to guarantee excellent stability.
Durable and Minimal Maintenance
Without non-returning valve that is usually used on troublesome hand pump.
Easy-to-use
Pressure could be set and adjusted precisely and quickly through a simple turn of the handle.
Hand-tight Quick Connectors
Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.
SPECIFICATIONS
Media: Air.
Generated Pressure Range
6 psi (0.4 bar) vacuum to 6 psi (0.4 bar) positive pressure.
Adjustment Resolution: 0.1 Pa (0.001 mbar).
Material:
Ram/adapters: SS
Body: SS, aluminum
Seals: Buna-N, PTFE, Copper Alloy
Connection
Hand-tight connectors for both test gauge and reference gauge.
1/4NPT female, 1/2NPT female, 1/4BSP female, 1/2BSP female, or M20X1.5 female
Dimensions: Height: 5.7'' (145mm)
Base: 9.65'' (245 mm) x 6.50'' (165mm)
Weight: 3.5 lb (1.6 kg).
Warranty: 1 year.
Optional Accessories
ORDERING INFORMATION
Model number Description
Model Number
ADT901 N
ADT901-X-kit
ADT901-HD
Test kit for ADT901 (barb fitting, connection hoses, and adapters).
X=connection type e.g. N-1/4NPTM, N2-1/2NPTM, B-1/4BSPM, B2-1/2BSPM,
M-M20X1.5M.
Holder for Additel 681 differential gauge or 672 differential calibrator.
Model
Pressure port type:
ADT102
Adapters and fittings, 1/4NPT male to various male and female connection (25 pcs). More information shown on page 61.
N -
1/4
NPT female
N2 - 1/2NPT female
B - 1/4BSP female
ADT103
Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.
B2 - 1/2BSP female
M-M20X1.5 female
ADT100-HTK
9901-901
Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT (1/8NPT,
1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) female hand-tight quick connector.
More information shown on page 63.
Carrying Case for one ADT901 pump and two ADT681 gauges or ADT672 calibrators
Accessories included
O-ring: 20 pcs
ADT901-MK Maintenance kit for Additel 901 pump
Manual: 1 pc
9240 DP gauge holder, rubber
Note: For O
2
-clean applications contact Additel.
Look us up on www.additel.com or call today (1)714-998-6899
Additel 912
Low Pressure Test Pump
Generate 95% vacuum to 60 psi (4 bar) pressure
Portable
Great stability and high resolution
Minimal maintenance
Hand-tight quick connectors
OVERVIEW
The 912 Pneumatic Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 60 psi (4 bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up to 0.1 Pa (0.001 mbar). The 912 is a very stable low pressure calibrator. It makes use of an isothermal bellows chamber which is designed for reducing the possible effects of environmental temperature change. Most pumps make use of a check valve (non-returning valve) and are not well insulated which will cause large fluctuations in pressure with a change in ambient temperature or when the unit is touched. The 912 does not use a check valve and is remarkably stable. Two hand-tight connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 912 is an ideal comparison test pump for low pressure application.
FEATURES
Portable: Only 6.2 lb (2.8 kg)
Adjustment Resolution
0.1Pa (0.001 mbar)
High-quality screw press for fine pressure adjustment
Great Stability
Isothermal chamber: the pressure chamber is insulated to reduce the influence from environmental temperature changes
Specially designed bellows minimize leakage to guarantee excellent stability
Shut-off valve closes the air in the isothermal chamber during calibration
Durable and Minimal Maintenance
Built-in gas-liquid isolator protects the pump from moisture and dirt
Easy-to-use
Hand-tight Quick Connectors
Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches
SPECIFICATIONS
Media: Air.
Generated Pressure Range
95% vacuum to 60 psi (4bar) positive pressure
Adjustment Resolution: 0.1 Pa (0.001 mbar).
Material: Ram/adapters: SS
Body: SS, aluminum
Seals: Buna-N, PTFE, Copper Alloy
Piston volume: 21 ml (1.3 in
Connection
3
)
Hand-tight connectors for both test gauge and reference gauge.
1/4NPT female, 1/2NPT female, 1/4BSP female, 1/2BSP female, or M20X1.5 female
Dimensions
Height: 5.51'' (140 mm)
Base: 10.75'' (273 mm) x 10.16'' (258 mm)
Weight: 6.2 lb (2.8 kg).
Warranty: 1 year
ORDERING INFORMATION
Model Number
ADT912 N
Model
Pressure port type:
N -
1/4
NPT female
N2 - 1/2NPT female
B - 1/4BSP female
B2 - 1/2BSP female
M - M20X1.5 female
Accessories included
O-ring: 20 pcs
Manual: 1 pc
Optional Accessories
Model number
ADT912-X-kit
ADT102
ADT103
ADT100-HTK
9904-912
Description
Test kit for ADT912 (barb fitting, connection hoses, and adapters).
X=connection type e.g. N-1/4NPTM, N2-1/2NPTM, B-1/4BSPM, B2-1/2BSPM,
M-M20X1.5M.
Adapters and fittings, 1/4NPT male to various male and female connection (25 pcs). More information shown on page 61.
Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.
Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT (1/8NPT,
1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) female hand-tight quick connector.
More information shown on page 63.
Carrying Case for one 912 pump and two 681 gauges or 672 calibrators.
ADT912-MK Maintenance kit for Additel 912 pump
9240 DP gauge holder, rubber
Note: For O
2
-clean applications contact Additel.
Look us up on www.additel.com or call today (1)714-998-6899
41
Additel 914
Handheld Pneumatic Pressure Test Pump
Generate 95% vacuum to 375 psi (25 bar) pressure
Portable, only 3.3 lb
Great stability and high resolution
Minimal maintenance
Hand-tight quick connectors
OVERVIEW
The 914 Pneumatic Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 375 psi (25 bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up to10 Pa (0.1 mbar). A specially designed shut-off valve makes the pressure as stable as possible during calibration. A built-in gas-liquid isolator protects the pump from moisture and dirt to reduce the need for maintenance.
Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 914 is an ideal comparison test pump for pressure instruments calibration.
FEATURES
Portable:
Only 3.3 lb (1.5 kg)
Adjustment Resolution
10 Pa (0.1 mbar)
High-quality screw press for fine pressure adjustment
Great Stability
A specially designed shut-off valve makes the pressure as stable as possible during calibration
Durable and Minimal Maintenance
Built-in gas-liquid isolator protects the pump from moisture and dirt
Easy-to-use
Hand-tight Quick Connectors
Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches
SPECIFICATIONS
Media: Air.
Generated Pressure Range: 95% vacuum to 375 psi (25 bar) positive pressure
Adjustment Resolution: 10 Pa (0.1 mbar).
Material: Ram/adapters: SS
Body: SS, aluminum
Seals: Buna-N, PTFE, Copper Alloy
Piston volume: 21 ml (1.3 in
Connection
3
)
Hand-tight connectors for both test gauge and reference gauge.
1/4NPT female, 1/2NPT female, 1/4BSP female,
1/2BSP female, or M20X1.5 female
Dimensions
Height: 5.12'' (130 mm)
Base: 9.45'' (240 mm) x 4.72'' (120 mm)
Weight: 3.3 lb (1.5 kg).
Warranty: 1 year
42
ORDERING INFORMATION
Model Number
ADT914
Model
N
Pressure port type:
N -
1/4
NPT female
N2 - 1/2NPT female
B - 1/4BSP female
B2 - 1/2BSP female
M - M20X1.5 female
Accessories included
O-ring: 20 pcs
Manual: 1 pc
Optional Accessories
Model number
ADT102
ADT103
ADT100-HTK
Description
Adapters and fittings, 1/4NPT male to various male and female connection
(25 pcs). More information shown on page 61.
Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.
Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT
(1/8NPT, 1/2NPT, 1/4BSP, 1/2 BSP, or M20X1.5) female hand-tight quick connector. More information shown on page 63.
Carrying Case for one 914 pump and two 681 gauges or 672 calibrators 9901-914
ADT914-MK Maintenance kit for Additel 914 pump
Note: For O
2
-clean applications contact Additel.
Look us up on www.additel.com or call today (1)714-998-6899
Additel 916
Pneumatic Pressure Test Pump
Generate 95% vacuum to 600 psi (40 bar) pressure
Portable, only 5.9 lb
Great stability and high resolution
Minimal maintenance
Hand-tight quick connectors
OVERVIEW
The 916 Pneumatic Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 600 psi (40 bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up to 10 Pa (0.1 mbar). A specially designed shut-off valve makes the pressure as stable as possible during calibration. A built-in gas-liquid isolator protects the pump from moisture and dirt to reduce the need for maintenance.
Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 916 is an ideal comparison test pump for pressure instruments calibration.
FEATURES
Portable
Only 5.9 lb (2.7 kg)
Adjustment Resolution
10 Pa (0.1 mbar)
High-quality screw press for fine pressure adjustment
Great Stability
A specially designed shut-off valve makes the pressure as stable as possible during calibration.
Durable and Minimal Maintenance
Built-in gas-liquid isolator protects the pump from moisture and dirt.
Easy-to-use
Hand-tight Quick Connectors
Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.
SPECIFICATIONS
Media: Air.
Generated Pressure Range
95% vacuum to 600 psi (40 bar) positive pressure
Pressure Resolution: 10 Pa (0.1 mbar).
Material
Ram/adapters: SS
Body: SS, aluminum
Seals: Buna-N, PTFE, Copper Alloy
Piston volume: 21 ml (1.3 in
Connection
3
)
Hand-tight connectors for both test gauge and reference gauge.
1/4NPT female, 1/2NPT female, 1/4BSP female, 1/2BSP female, or M20X1.5 female
Dimensions
Height: 5.5'' (140 mm)
Base: 12.4'' (315 mm) x 7.8'' (198 mm)
Weight: 5.9 lb (2.7 kg).
Warranty:1 year
ORDERING INFORMATION
Model Number
ADT916 N
Model
Pressure port type:
N -
1/4
NPT female
N2 - 1/2NPT female
B - 1/4BSP female
B2 - 1/2BSP female
M - M20X1.5 female
Accessories included
O-ring: 20 pcs
Manual: 1 pc
Optional Accessories
Model numberel Description
ADT102
ADT103
ADT100-HTK
9904-916
Adapters and fittings, 1/4NPT male to various male and female connection
(25 pcs). More information shown on page 61.
Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.
Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT
(1/8NPT, 1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) female hand-tight quick connector. More information shown on page 63.
Carrying Case for one ADT916 pump and two ADT681 gauges or ADT672 calibrators
ADT916-MK Maintenance kit for Additel 916 pump
Note: For O
2
-clean applications contact Additel.
Look us up on www.additel.com or call today (1)714-998-6899
43
Additel 917
Pneumatic Pressure Test Pump
Generate 95% vacuum to 1,000 psi (70 bar) pressure
Portable, only 5.7 lb
Great stability and high resolution
Minimal maintenance
Hand-tight quick connectors
OVERVIEW
The 917 Pneumatic Pressure Test Pump is a hand operated pressure pump designed to generate pressure from
95% vacuum to 1,000 psi (70 bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up to 10 Pa (0.1 mbar). A specially designed shut-off valve makes the pressure as stable as possible during calibration. A built-in gas-liquid isolator protects the pump from moisture and dirt to reduce the need for maintenance. The 917 can be special ordered to comply with oxygen free applications. Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for
PTFE tape or wrenches. The 917 is an ideal comparison test pump for pressure instruments calibration.
FEATURES
Portable
Only 5.7 lb (2.6 kg)
High Resolution
10 Pa (0.1 mbar)
High-quality screw press for fine pressure adjustment
Great Stability
A specially designed shut-off valve makes the pressure as stable as possible during calibration.
Durable and Minimal Maintenance
Built-in gas-liquid isolator protects the pump from moisture and dirt.
Easy-to-use
Pressurized to desired pressure by the lever directly and make fine adjustment. No high-pressurized valve needed.
Hand-tight Quick Connectors
Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.
SPECIFICATIONS
Media: Air.
Generated Pressure Range
95% vacuum to 1,000 psi (70 bar) positive pressure
Adjustment Resolution: 10 Pa (0.1 mbar).
Material: Ram/adapters: SS
Body: SS, aluminum
Seals: Buna-N, PTFE, Copper Alloy
Piston volume: 27 ml (1.6 in
3
)
Connection:
Hand-tight connectors for both test gauge and reference gauge.
1/4NPT female, 1/2NPT female, 1/4BSP female,
1/2BSP female, or M20X1.5 female
Dimensions:
Height: 5.5'' (140 mm)
Base: 12.4" (315 mm) x 7.8" (198 mm)
Weight: 5.7 lb (2.6 kg).
Warranty: 1 year
44
ORDERING INFORMATION
Model Number
ADT917 N
Model
Pressure port type:
N -
1/4
NPT female
N2 - 1/2NPT female
B - 1/4BSP female
B2 - 1/2BSP female
M - M20X1.5 female
Accessories included
O-ring: 20 pcs
Manual: 1 pc
Optional Accessories
Model number
ADT102
ADT103
ADT100-HTK
Description
Adapters and fittings, 1/4NPT male to various male and female connection
(25 pcs). More information shown on page 61.
Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.
Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT
(1/8NPT, 1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) female hand-tight quick connector. More information shown on page 63.
Carrying Case for one 917 pump and two 681 gauges or 672 calibrators 9904-917
ADT917-MK Maintenance kit for Additel 917 pump
Note: For O
2
-clean applications contact Additel.
Look us up on www.additel.com or call today (1)714-998-6899
Additel 918
Pneumatic Pressure Test Pump
Generate 95% vacuum to 1,500 psi (100 bar) pressure
Portable, only 5.7 lb
Great stability and high resolution
Minimal maintenance
Hand-tight quick connectors
OVERVIEW
The 918 Pneumatic Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 1,500 psi (100 bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up to 10 Pa (0.1 mbar). A specially designed shut-off valve makes the pressure as stable as possible during calibration. A built-in gas-liquid isolator protects the pump from moisture and dirt to reduce the need for maintenance.
The 918 can be special ordered to comply with oxygen free applications. Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The
918 is an ideal comparison test pump for pressure instruments calibration.
FEATURES
Portable
Only 5.7 lb (2.6 kg)
High Resolution
0.001psi (10 Pa , 0.1 mbar)
High-quality screw press for fine pressure adjustment
Great Stability
A specially designed shut-off valve makes the pressure as stable as possible during calibration.
Durable and Minimal Maintenance
Built-in gas-liquid isolator protects the pump from moisture and dirt.
Easy-to-use
Pressurize to desired pressure by the pump lever directly, and then make fine adjustment. No highpressure valve needed.
Hand-tight Quick Connectors
Allows easy connection and disconnection to the test pump without the need for PTFE tape or wrenches.
SPECIFICATIONS
Media: Air.
Generated Pressure Range
95% vacuum to 1,500 psi (100 bar) positive pressure
Adjustment Resolution: 0.001 psi (10 Pa , 0.1 mbar).
Material: Ram/adapters: SS
Body: SS, aluminum
Seals: Buna-N, FTM, PTFE, Copper Alloy
Piston volume: 27 ml (1.6 in 3
)
Connection: Hand-tight connectors for both test gauge and reference gauge.
1/4NPT female, 1/2NPT female, 1/4BSP female,
1/2BSP female, or M20X1.5 female
Dimensions:
Height: 5.5'' (140 mm)
Base: 12.4" (315 mm) x 7.8" (198 mm)
Weight: 5.7 lb (2.6 kg).
Warranty: 1 year
ORDERING INFORMATION
Model Number
ADT918 N
Model
Pressure port type:
N -
1/4
NPT female
N2 - 1/2NPT female
B - 1/4BSP female
B2 - 1/2BSP female
M - M20X1.5 female
Accessories included
O-ring: 20 pcs
Manual: 1 pc
Optional Accessories
Model number
ADT102
ADT103
ADT100-HTK
Description
Adapters and fittings, 1/4NPT male to various male and female connection
(25 pcs). More information shown on page 61.
Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.
Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT
(1/8NPT, 1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) female hand-tight quick connector. More information shown on page 63.
Carrying Case for one 918 pump and two 681 gauges or 672 calibrators 9904-918
ADT918-MK Maintenance kit for Additel 918 pump
Note: For O
2
-clean applications contact Additel.
Look us up on www.additel.com or call today (1)714-998-6899
45
46
Additel 919A
High Pressure Test Pump
Generate 95% vacuum to 2,000 psi (140 bar) pressure
Generate 2,000 psi (140 bar) in 30 seconds
Minimal maintenance
Hand-tight quick connectors
First one in the world
OVERVIEW
The 919A High Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 2,000 psi (140 bar). With a long lever, it just takes 30 seconds to reach 2,000 psi (140 bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up to 0.001 psi (10 Pa , 0.1 mbar).
A specially designed shut-off valve makes the pressure as stable as possible during calibration. A built-in gas-liquid isolator protects the pump from moisture and dirt to reduce the need for maintenance. The residual liquid in the pump introduced from the devices under test will be collected and then pushed out during pressure release. Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for
PTFE tape or wrenches. The 919A is an ideal comparison test pump for pressure instruments calibration.
FEATURES
High Efficiency
Generate 2,000 psi (140 bar) in 30 seconds.
Adjustment Resolution
0.001 psi (10 Pa , 0.1 mbar).
High-quality screw press for fine pressure adjustment.
Great Stability
A specially designed shut-off valve makes the pressure as stable as possible during calibration.
Durable and Minimal Maintenance
Built-in gas-liquid isolator protects the pump from moisture and dirt.
The residual liquid in the pump introduced from devices under test will be collected and then pushed out and collected during pressure release.
Anticorrosive and wear resistant material are used to improve the reliability further.
Hand-tight Quick Connectors
Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.
SPECIFICATIONS
Media: Air.
Generated Pressure Range: 95% vacuum to 2,000 psi
(140 bar) positive pressure
Adjustment Resolution: 10 Pa (0.1 mbar/0.0015 psi)
Material: Ram/adapters: SS
Body: SS, aluminum
Seals: Buna-N, PTFE, Copper Alloy
Piston volume: 60 ml (3.7 in
3
)
Connection
Hand-tight connectors for both test gauge and reference gauge.
1/4NPT female, 1/2NPT female, 1/4BSP female,
1/2BSP female, or M20X1.5 female
Dimensions:
Height: 7.00'' (178 mm);
Base: 21.26' (540 mm) x 10.63'' (270 mm).
Weight: 14.3 lb (6.5 kg).
Warranty: 1 year
ORDERING INFORMATION
Model Number
ADT919A N
Model
Pressure port type:
N -
1/4
NPT female
N2 - 1/2NPT female
B - 1/4BSP female
B2 - 1/2BSP female
M - M20X1.5 female
Accessories included
O-ring: 20 pcs
Manual: 1 pc
Optional Accessories
Model number
ADT102
ADT103
ADT100-HTK
Description
Adapters and fittings, 1/4NPT male to various male and female connection
(25 pcs). More information shown on page 61.
Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.
Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT
(1/8NPT, 1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) female hand-tight quick connector. More information shown on page 63.
Carrying Case for one 919A pump and two 681 gauges or 672 calibrators 9909-919A
ADT919A-MK Maintenance kit for Additel 919A pump
Note: For O
2
-clean applications contact Additel.
Look us up on www.additel.com or call today (1)714-998-6899
Application Note
Improved Methods for High Pressure Pneumatic Calibrations in the Field
Are you tired of dragging a nitrogen bottle and dead weight tester out to the field to perform pneumatic high pressure calibrations? Does it trouble you to use a hydraulic pump or dead weight tester for your gas gauges every time you have to go above 600 psi? This application note details the limitations to traditional methods and provides a solution to calibration of gas gauges up to 3,000 psi (200 bar) with a field-ready calibration tool.
Limitations with Traditional Methods
Traditional methods for performing high pressure gas gauge calibrations in the field require the use of a controller or comparison systems and a nitrogen bottle. This solution typically provides the performance needed to do the job but adds a considerable inconvenience in having to transport several pieces of heavy equipment to the calibration site.
Not to mention the time and effort in setting up the system. Dead weight testers and hydraulic pumps have also been used as a solution. Hydraulic pumps are problematic for this application as the liquid can damage the gas gauge you are attempting to calibrate. It is common that these hydraulic comparison pumps also lack the stability and resolution required to calibrate many gas gauges. Dead weight testers typically have the accuracy required but will require a gas supply for high pressure pneumatic applications. If the dead weight tester uses hydraulic fluid as the medium it will achieve much higher pressures but has similar drawbacks as hydraulic pumps.
A More Practical Solution
Additel developed their high pressure pneumatic pumps specifically to address high pressure gas calibrations in the field. The Additel 919A goes to 2,000 psi (140 bar) and the 920 goes to 3,000 psi (200 bar) without the use of hydraulic fluids or the need for a gas supply. Each pump can also generate to 95% of vacuum. The ADT920 will generate
3,000 psi (200 bar) in 40 seconds and the pump weighs about 14 lbs (6.5 kg) which makes it easy to take to the field.
The high pressure range, portability, and speed to pressure are not the only things that make this series of pumps unique. The Additel pneumatic pump design allows for high stability and resolution to 0.001 psi (0.1 mbar). Like many pumps on the market, the ADT919A and the ADT920 use a check valve, also referred to as a non-returning valve, to protect the pump from contaminants that could cause damage. However, we've seen with most pumps on the market that the check valve tends to lose its seal over time which causes unstable measurements. The Additel design incorporates a high-quality isolation valve and screw press which allows for you to isolate the calibration volume from the check valve and achieve very stable measurements and resolution to 0.001 psi (0.1 mbar).
The diagram below illustrates the pump construction.
The method of operation is as follows: To generate pressure, use the pump handle on top of the unit. When you've generated 70% - 80% of the desired pressure with the pump handle, then close the isolation valve (this isolates the calibration volume from the pump handle and check valve). Next, use the fine-adjust screw press to generate the remaining pressure. Each pump comes with two hand-tight, quick-connect pressure ports that do not require the use of PTFE tape or wrenches. Combine this pump with any of our digital pressure gauges and you have an accurate, portable and practical field calibration solution for gas calibrations up to 3,000 psi (200 bar).
Conclusion
Traditional solutions for high pressure gas calibrations are not convenient or practical for field applications or they require the use of hydraulic fluids which could damage the sensor being tested. The Additel 919A and 920 pneumatic pressure pumps solve many of the problems that exist with traditional solutions and provide a reliable, field-ready, accurate and affordable solution to meet your needs!
Look us up on www.additel.com or call today (1)714-998-6899
47
48
Additel 920
High Pressure Test Pump
Generate 95% vacuum to 3,000 psi (200 bar) pressure
Generate 3,000 psi (200 bar) in 40 seconds
Minimal maintenance
Hand-tight quick connectors
First one in the world
OVERVIEW
The 920 High Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 3,000 psi (200 bar). With a long lever, it just takes 40 seconds to reach 3,000 psi (200 bar). A highquality screw press is designed for fine pressure adjustment, with an adjustment resolution up to 10 Pa (0.1 mbar).
A specially designed shut-off valve makes the pressure as stable as possible during calibration. A built-in gas-liquid isolator protects the pump from moisture and dirt to reduce the need for maintenance. The residual liquid in the pump introduced from devices under test will be pushed out and collected during pressure release. Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 920 is an ideal comparison test pump for pressure instruments calibration.
FEATURES
High Efficiency
Generate 3,000 psi (200 bar) in 40 seconds.
Adjustment Resolution
0.001 psi (10 Pa, 0.1 mbar).
High-quality screw press for fine pressure adjustment.
Great Stability
A specially designed shut-off valve makes the pressure as stable as possible during calibration.
Durable and Minimal Maintenance
Built-in gas-liquid isolator protects the pump from moisture and dirt.
The residual liquid in the pump introduced from devices under test will be collected and then pushed out and collected during pressure release.
Anticorrosive and wear resistant material are used to improve the reliability further.
Hand-tight Quick Connectors
Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.
SPECIFICATIONS
Media: Air.
Generated Pressure Range
95% vacuum to 3,000 psi (200 bar) positive pressure
Adjustment Resolution: 10 Pa (0.1 mbar/0.0015 psi)
Material: Ram/adapters: SS
Body: SS, aluminum
Seals: Buna-N, F357, PTFE, Copper Alloy
Piston volume: 60 ml (3.7 in
3
)
Connection
Hand-tight connectors for both test gauge and reference gauge.
1/4NPT female, 1/2NPT female, 1/4BSP female,
1/2BSP female, or M20X1.5 female
Dimensions:
Height: 7.00'' (178 mm);
Base: 21.26' (540 mm) x 10.63'' (270 mm).
Weight: 14.3 lb (6.5kg).
Warranty:: 1 year
ORDERING INFORMATION
Model Number
ADT920 N
Model
Pressure port type:
N -
1/4
NPT female
N2 - 1/2NPT female
B - 1/4BSP female
B2 - 1/2BSP female
M - M20X1.5 female
Accessories included
O-ring: 20 pcs
Manual: 1 pc
Optional Accessories
Model number
ADT102
ADT103
ADT100-HTK
Description
Adapters and fittings, 1/4NPT male to various male and female connection
(25 pcs). More information shown on page 61.
Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.
Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT
(1/8NPT, 1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) female hand-tight quick connector. More information shown on page 63.
Carrying Case for one 920 pump and two 681 gauges or 672 calibrators 9909-920
ADT920-MK Maintenance kit for Additel 920 pump
Note: For O
2
-clean applications contact Additel.
Look us up on www.additel.com or call today (1)714-998-6899
Additel 925
Handheld Hydraulic Pressure Test Pump
Generate 85% vacuum to 6,000 psi (400 bar) pressure
Portable, only 3.7 lb
Minimal maintenance
Increase and decrease pressure smoothly
Hand-tight quick connectors
OVERVIEW
The 925 Hydraulic Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 85% vacuum to 6,000 psi (400 bar). With the patented screw press technology, the high pressure can be easily generated, as well as increased and decreased smoothly. With no check valve (non-returning valve), the 925 avoids the troublesome leakage issues that is usually experienced with most hand pumps and allows for minimal maintenance. Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for
PTFE tape or wrenches. The 925 is an ideal comparison test pump for calibrating pressure measuring instruments such as test gauges, indicators or transducers in the field or laboratory.
FEATURES
Portable
Only 3.7 lb (1.7 kg)
Durable and Minimal Maintenance
Patented screw press technology, without non-returning valve inside that is usually used on troublesome hand pumps.
Easy-to-use
The high pressure can be generated easily, as well as increased and decreased smoothly.
Extremely Low Leakage
Patented screw press technology, replaces troublesome check valves (non-returning valve) used in most hand pumps which practically eliminates leakage.
Hand-tight Quick Connectors
Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.
SPECIFICATIONS
Media: Oil or deionized water.
(Oil is default media liquid. Pump with water as media to be ordered specifically)
Reservoir capacity: 200 ml (12.2 in
Pressure Range
3
)
85% vacuum to 6,000 psi (400 bar) positive pressure.
Material: Ram/adapters: SS
Body: SS,aluminum
Seals: Buna-N, PTFE, Copper Alloy
Connection
Hand-tight connectors for both test gauge and reference gauge.
1/4NPT female, 1/2NPT female, 1/4BSP female,
1/2BSP female, or M20X1.5 female
Dimensions: Height: 4.72'' (120 mm)
Base: 9.84'' (250 mm) x 5.51'' (140 mm)
Weight: 3.7 lb (1.7 kg).
Warranty: 1 year
Piston volume
Low pressure piston: 18 ml (1.1 in
3
)
High pressure piston: 0.9 ml (0.05 in
3
)
ORDERING INFORMATION
Model Number
ADT925 N
Model Pressure port type:
N -
1/4
NPT female
N2 - 1/2NPT female
B - 1/4BSP female
B2 - 1/2BSP female
M - M20X1.5 female
Accessories included
Mineral oil,1 bottle (250 ml)*
O-ring: 20 pcs
Manual: 1 pc
* When water media is not requested
Optional Accessories
Model number
9201
ADT102
ADT103
ADT100-HTK
9901-925
ADT925-MK
Description
Oil, Diethylhexyl Sebacate, 1 liter (1 quart)
Adapters and fittings, 1/4NPT male to various male and female connection
(25 pcs). More information shown on page 61.
Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.
Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT
(1/8NPT, 1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) female hand-tight quick connector. More information shown on page 63.
Carrying Case for one 925 pump and two 681 gauges or 672 calibrators
Maintenance kit for Additel 925 pump
Look us up on www.additel.com or call today (1)714-998-6899
49
50
Application Note
Considerations for Hydraulic High Pressure Calibrations
If you are doing high pressure, hydraulic calibrations there are a few things that you'll need to consider which will make your life a little easier and help you produce stable measurements. This application note focuses on considerations for pressure calibrations using a high pressure hydraulic pump to generate the pressure.
Getting Started
To produce stable and high pressure measurements using a hydraulic calibration pump, the gas within the calibration system needs to be removed.
Hydraulic test pumps use various types of fluids to generate high pressures.
Because gas is much more compressible than liquid, purging most if not all the gas out of the system will allow for maximum pressures to be generated.
The following steps describe the procedure to purge the gas from an Additel test pump:
1. Ensure the pump, reference standard, and device under test (DUT) are securely connected to the calibration pump.
2. Close the vent valve and screw out the main screw press. You should see a vacuum being pulled on your reference and DUT
(assuming the reference and the DUT are able to be used for vacuum measurement).
3. Open the vent valve, wait for the pressure to settle to zero, and screw in the main screw press. As you do this, you may see bubbles emerge in the medium reservoir which is a good indication that gas is being pushed out of the system.
4. Close the vent valve and repeat steps 2 and 3 one or two more times.
5. Close the vent valve and unscrew the main screw press half way out. Then open the vent valve to zero the measurement.
6. Now, you are ready to close the vent valve and generate pressure.
Vent
Main screw press
Stable Measurements
As pressures are generated to the desired test point it is common to initially observe a fairly rapid decrease in pressure.
Initially, you may conclude that this is a pressure leak but what you are likely observing is called the adiabatic effect. This effect is defined as a gain or loss of heat within a system and its environment. When a gas is compressed under adiabatic conditions, its pressure increases and its temperature rises without the gain or loss of any heat. This happens when the screw press of a pump compresses the fluid volume, thus resulting in an increase in pressure but also an increase in the temperature. As the increase in pressure stops the temperature generated from the screw press dissipates. If the volume is held constant and the temperature decreases so also will the pressure decrease. So this initial degrease of pressure is in fact a result of the temperature settling from the adiabatic heating effect generated from the screw press of the pump.
Other sources of instability that also impact the pressure measurement are instabilities in room temperature and changes in volume. Because temperature is a factor of pressure as the entire pressure system changes temperature due to the room temperature changing the true pressure value will also change. The same can also be said of the pressure volume.
With an increase or decrease of pressure volume the true pressure value will see a correlated change. Volume changes with pressure systems are usually not very noticeable except at high pressures. At high pressures, the materials where the pressurized volume is contained will slightly expand causing the volume to expand and the pressure will decrease.
This is particularly evident when using flexible hoses at high pressures.
Conclusion
So we can't change the laws of physics—so what can be done? As pressures are generated, time must be given to allow for the adiabatic effects to settle. In other words, you need to let the measurement stabilize for a few minutes. As you allow this stabilization period to happen, you'll find the measurement stability of the pump to be very reliable for your calibration applications. Room temperature will also have an impact on the measurement and it is best if calibrations are performed in a controlled, stable environment. Lastly, careful consideration of hoses, manifolds, and tubing will help produce stable results at high pressures. Using metal tubing as opposed to flexible hoses will yield higher stability as metal is less likely to allow for the volume to expand when under high pressure.
Look us up on www.additel.com or call today (1)714-998-6899
Additel 927
Hydraulic Pressure Test Pump
Generate 85% vacuum to 10,000 psi (700 bar) pressure
Portable, only 7 lb
Minimal maintenance
Increase and decrease pressure smoothly
Hand-tight quick connectors
OVERVIEW
The 927 Hydraulic Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 85% vacuum to 10,000 psi (700 bar). With the patented screw press technology, high pressures can be easily generated, as well as increased and decreased smoothly. With no check valve (non-returning valve), the 927 avoids the troublesome leakage issues that is usually experienced with most hand pumps and allows for minimal maintenance. Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 927 is an ideal comparison test pump for calibrating pressure measuring instruments such as test gauges, indicators or transducers in the field or laboratory.
FEATURES
Portable
Only 7 lb
Durable and Minimal Maintenance
Patented screw press technology, without nonreturning valve inside that is usually used on troublesome hand pumps.
Easy-to-use
The high pressure can be generated easily, as well as increased and decreased smoothly.
Extremely Low Leakage
Patented screw press technology, replaces troublesome check valves (non-returning valve) used in most hand pumps which practically eliminates leakage.
Hand-tight Quick Connectors
Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.
ORDERING INFORMATION
Model Number
ADT927 N
SPECIFICATIONS
Media: Oil or deionized water.
(Oil is default media liquid. Pump with water as media to be ordered specifically)
Reservoir capacity: 245 ml (15 in
Generated Pressure Range
3
)
85% vacuum to 10,000 psi (700 bar) positive pressure.
Material: Ram/adapters: SS
Body: SS, aluminum
Seals: Buna-N, PTFE, Copper Alloy
Connection
Hand-tight connectors for both test gauge and reference gauge.
1/4NPT female, 1/2NPT female, 1/4BSP female,
1/2BSP female, or M20X1.5 female
Dimensions: Height: 5.31'' (135 mm)
Base: 11.42'' (290 mm) x 7.80'' (198 mm).
Weight: 7 lb (3.2 kg).
Warranty: 1 year
Piston volume
Low pressure piston: 19 ml (1.2 in
3
)
High pressure piston: 0.9 ml (0.05 in
3
)
Model
Pressure port type:
N -
1/4
NPT female
N2 - 1/2NPT female
B - 1/4BSP female
B2 - 1/2BSP female
M - M20X1.5 female
Accessories included
Mineral oil,1 bottle (250 ml)*
O-ring: 20 pcs
Manual: 1 pc
* When water media is not requested
Optional Accessories
Model number
9201
ADT102
ADT103
ADT100-HTK
9904-927
ADT927-MK
Description
Oil, Diethylhexyl Sebacate, 1 liter (1 quart)
Adapters and fittings, 1/4NPT male to various male and female connection
(25 pcs). More information shown on page 61.
Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.
Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT
(1/8NPT, 1/2NPT, 1/4BSP,1/2BSP, or M20X1.5) female hand-tight quick connector. More information shown on page 63.
Carrying Case for one 927 pump and two 681 gauges or 672 calibrators
Maintenance kit for Additel 927 pump
Look us up on www.additel.com or call today (1)714-998-6899
51
52
Additel 928
Hydraulic Pressure Test Pump
Pressurize large-volume workload
Generate to 15,000 psi (1,000 bar) pressure
Portable only 8.6 lbs (3.9 kg)
Increase and decrease pressure smoothly
Hand-tight quick connectors
OVERVIEW
The Additel 928 Hydraulic Pressure Test Pump is a hand operated pressure pump designed to generate pressure to
15,000 psi (1,000 bar). This pump incorporates a dual-piston system which is ideal for filling large volume workload with the hand pump and providing smooth increase and decrease of pressure with the fine adjustment. The 928 Test
Pump incorporates an isolation valve which isolates the calibration volume from the check valve associated with the hand pump. Because the check valve can often be a source of leaks and maintenance, the isolation valve provides more stable measurements and reduces potential maintenance of the pump. Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.
The Additel 928 is an ideal comparison test pump for calibrating pressure measuring instruments such as test gauges, indicators or transducers in the field or laboratory.
FEATURES
Hand pump to fill large volume systems
Portable at 8.6 lbs (3.9 kg)
Durable and minimal maintenance
Isolation valve provides stable pressures while reducing maintenance on the hand pump check valve
Easy to use
15,000 psi (1,000 bar) can be generated easily with the dual-piston system
Hand-tight quick connectors
Allows easy connection and disconnection to the test pump without the need for PTFE tape or wrenches
SPECIFICATIONS
Media: Mineral oil or deionized water.
(Oil is default media liquid. Pump with water as media to be ordered specifically)
Generated Pressure Range
0 to 15,000 psi (1,000bar) gauge pressure
Material: Ram/adapters: SS
Body: SS, aluminum
Seals: Buna-N, PTFE, Copper Alloy
Connection
Hand-tight connectors for both test gauge and reference gauge.
1/4NPT female, 1/2NPT female, 1/4BSP female,
1/2BSP female, or M20X1.5 female
Dimensions: Height: 6.38'' (162 mm)
Base: 13.58'' (345 mm) x 8.46'' (215 mm)
Weight: 8.6 lb (3.9 kg)
Warranty: 1 year
Piston Volume: Fine adjust piston: 0.9ml (0.05 in
3
)
ORDERING INFORMATION
Model Number
Optional Accessories
ADT928 N
Model number
Model Pressure port type:
N -
1/4
NPT female
N2 - 1/2NPT female
B - 1/4BSP female
B2 - 1/2BSP female
M - M20X1.5 female
9202
ADT102
ADT103
ADT100-HTK
Accessories included
9202 Mineral oil,1 bottle (250 ml)*
O-ring: 20 pcs
Manual: 1 pc
* When water media is not requested
9904-928
ADT928-MK
ADT100-928-HK
Look us up on www.additel.com or call today (1)714-998-6899
Description
Oil, Mineral oil, 1 liter (1 quart)
Adapters and fittings, 1/4NPT male to various male and female connection
(25 pcs). More information shown on page 61.
Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.
Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT
(1/8NPT, 1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) female hand-tight quick connector. More information shown on page 63.
Carrying Case for one 928 pump and two pressure test gauges
Maintenance kit for Additel 928 pump
Hose Kit, External Reservoir Expansion Hose Kit for ADT928
Additel 936
Hydraulic High Pressure Calibration Pump
Generate 85% vacuum to 15,000 psi (1,000 bar) pressure
Minimal maintenance
Increase and decrease pressure smoothly
Three pressure ports
Hand-tight quick connectors
OVERVIEW
The 936 Hydraulic High Pressure Test Pump is a hand operated pressure pump designed to generate pressure from
85% vacuum to 15,000 psi (1,000 bar). With the patented screw press technology, high pressures can be easily generated, as well as increased and decreased smoothly. A specially designed shut-off valve makes the pressure as stable as possible during calibration. With no check valve (non-returning valve), the 936 avoids the troublesome leakage issues that is usually experienced with hand pumps and allows for minimal maintenance. Three hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 936 is an ideal comparison test pump for calibrating pressure measuring instruments such as test gauges, indicators or transducers in the laboratory.
FEATURES
High Pressure
Generates pressure up to 15,000 psi (1000 bar)
Durable and Minimal Maintenance
Patented screw press technology, without nonreturning valve inside that is usually used on troublesome hand pumps.
Easy-to-use
High pressures can be generated easily, as well as increased and decreased smoothly.
Extremely Low Leakage
Patented screw press technology replaces troublesome check valves (non-returning valve) in most hand pumps which practically eliminates leakage.
Hand-tight Quick Connectors
Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.
SPECIFICATIONS
Media: Oil
Reservoir capacity: 420 ml (25.6 in
Pressure Range
3
)
85% vacuum to 15,000 psi (1,000 bar) positive.
Material
Ram/adapters: SS
Body: SS/aluminum
Seals: Buna-N, PTFE, Copper Alloy, SS
Connection
Hand-tight connectors for both test gauge and reference gauge(s).
1/4NPT female, 1/2NPT female, 1/4BSP female,
1/2BSP female, or M20X1.5 female
Dimensions
Height: 9.1'' (230 mm)
Base: 20.5'' (520 mm) x 14.2'' (360 mm)
Weight: 35.2 lb (16 kg).
Warranty: 1 year
Piston volume
Low pressure piston: 30 ml (1.8 in
3
)
High pressure piston: 2.5 ml (0.15 in
3
)
ORDERING INFORMATION
Model Number
ADT936 N
Model
Pressure port type:
N -
1/4
NPT female
N2 - 1/2NPT female
B - 1/4BSP female
B2 - 1/2BSP female
M - M20X1.5 female
Accessories included
Mineral oil,1 bottle (250 ml)
O-ring: 20 pcs Manual: 1 pc
Optional Accessories
Model number
9201
ADT102
ADT103
9908
ADT936-MK
Description
Oil, Diethylhexyl Sebacate, 1 liter (1 quart)
Adapters and fittings, 1/4NPT male to various male and female connection
(25 pcs). More information shown on page 61.
Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.
Carrying case for 936, 937, 938 or 949.
Maintenance kit for Additel 936 pump
Look us up on www.additel.com or call today (1)714-998-6899
53
54
Additel 937
Hydraulic High Pressure Calibration Pump
Generate 85% vacuum to 15,000 psi (1,000 bar) pressure
Compatible to phosphoric acid ester fluid and Skydrol Oil
Increase and decrease pressure smoothly
Three pressure ports
Hand-tight quick connectors
OVERVIEW
The 937 Hydraulic High Pressure Calibration Pump is a hand operated pressure pump designed for calibrating pressure measuring instruments with phosphoric acid ester fluid and Skydrol oil in the range from 85% vacuum to 15,000 psi (1000 bar). With the patented screw press technology, high pressures can be easily generated, increased and decreased smoothly. A specially designed shut-off valve makes the pressure as stable as possible during calibration. With no check valve (non-returning valve), the 937 avoids the troublesome leakage issues that is usually experienced with hand pumps and allows for minimal maintenance. Three hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 937 is an ideal comparison test pump for calibrating pressure measuring instruments such as test gauges, indicators or transducers in the laboratory.
FEATURES
High Pressure
Generates pressure up to 15,000 psi (1,000 bar)
Durable and Minimal Maintenance
Patented screw press technology, with no check valve (non-returning valve) inside that is usually used on troublesome hand pumps causing leakage.
Easy-to-use
High pressures can be generated easily, as well as increased and decreased smoothly.
Hand-tight Quick Connectors
Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.
SPECIFICATIONS
Media: Compatible to phosphoric acid ester fluid and Skydrol Oil (should not be used for mineral oil)
Reservoir capacity: 420 ml (25.6 in
3
Pressure Range
)
85% vacuum to 15,000 psi (1,000 bar) positive.
Material: Ram/adapters: SS
Body: SS, aluminum
Seals: EPDM, PTFE, Copper Alloy
Connection
Hand-tight connectors for both test gauge and reference gauge(s).
1/4NPT female, 1/2NPT female, 1/4BSP female,
1/2BSP female, or M20X1.5 female
Dimensions
Height: 9.1'' (230 mm)
Base: 20.5'' (520 mm) x 14.2'' (360 mm)
Weight: 35.2 lb (16 kg).
Warranty: 1 year
Piston volume
Low pressure piston: 30 ml (1.8 in
3
)
High pressure piston: 2.5 ml (0.15 in
3
)
ORDERING INFORMATION
Model Number
ADT937 N
Model Pressure port type:
N -
1/4
NPT female
N2 - 1/2NPT female
B - 1/4BSP female
B2 - 1/2BSP female
M - M20X1.5 female
Accessories included
O-ring: 20 pcs Manual: 1 pc
Look us up on www.additel.com or call today (1)714-998-6899
Optional Accessories
Model number
ADT102
ADT103
9908
ADT937-MK
Description
Adapters and fittings, 1/4NPT male to various male and female connection
(25 pcs). More information shown on page 61.
Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.
Carrying case for 936, 937, 938 or 949.
Maintenance kit for Additel 937 pump
Additel 938
Hydraulic High Pressure Calibration Pump
Generate 85% vacuum to 15,000 psi (1,000 bar) pressure
Oil-free pressure instruments
Minimal maintenance
Easy-to-use
Three pressure ports
Hand-tight quick connectors
OVERVIEW
The 938 Hydraulic High Pressure Test Pump is specially designed for calibrating oil-free pressure measuring instruments in the range of 85% vacuum to 15,000 psi (1,000 bar). All parts used in the pump have been carefully cleaned to remove oil. The pump uses water as the media. With the patented screw press technology, high pressures can be easily generated, as well as increased and decreased smoothly. A specially designed shut-off valve makes the pressure as stable as possible during calibration. With no check valve (non-returning valve), the 938 avoids the troublesome leakage issues that is usually experienced with hand pumps and allows for minimal maintenance. Three hand-tight connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 938 is an ideal comparison test pump for calibrating oil-free pressure measuring instruments such as test gauges, indicators or transducers in the laboratory.
FEATURES
High Pressure
Generates pressure up to 15,000 psi (1,000 bar)
Durable and Minimal Maintenance
Patented screw press technology, without nonreturning valve inside that is usually used on troublesome hand pumps.
Easy-to-use
With the patented screw press technology, high pressures can be generated easily, as well as increased and decreased smoothly
Extremely Low Leakage
Patented screw press technology replaces troublesome check valves (non-returning valve) in most hand pumps which practically eliminates leakage.
Hand-tight Quick Connectors
Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.
ORDERING INFORMATION
Model Number
SPECIFICATIONS
Media: Deionized water
Reservoir capacity: 420 ml (25.6 in
Pressure Range
3
)
85% vacuum to 15,000 psi (1,000 bar) positive pressure.
Material
Ram/adapters: SS
Body: SS, aluminum
Seals: Buna-N, PTFE, Copper Alloy
Reservoir capacity: 420 ml (25.6 in
3
)
Connection
Hand-tight connectors for both test gauge and reference gauge.
1/4NPT female, 1/2NPT female, 1/4BSP female,
1/2BSP female, or M20X1.5 female
Dimensions
Height: 9.1'' (230 mm)
Base: 20.5'' (520 mm) x 14.2'' (360 mm)
Weight: 35.2 lb (16 kg).
Warranty: 1 year
Piston volume
Low pressure piston: 30 ml (1.8 in
3
)
High pressure piston: 2.5 ml (0.15 in
3
)
ADT938 N
Optional Accessories
Model Pressure port type:
N -
1/4
NPT female
N2 - 1/2NPT female
B - 1/4BSP female
B2 - 1/2BSP female
M - M20X1.5 female
Accessories included
O-ring: 20 pcs
Manual: 1 pc
Model number
ADT102
ADT103
9908
ADT938-MK
Description
Adapters and fittings, 1/4NPT male to various male and female connection
(25 pcs). More information shown on page 61.
Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.
Carrying case for 936, 937, 938 or 949.
Maintenance kit for Additel 938 pump
Look us up on www.additel.com or call today (1)714-998-6899
55
56
Additel 946
Hydraulic High Pressure Calibration Pump
Pressureize large-volume worklaoad
Generate pressure to 15,000 psi (1,000 bar)
Increase and decrease pressure smoothly
Three pressure ports
Hand-tight quick connectors
OVERVIEW
The new Additel 946 Hydraulic Pressure Test Pump is a benchtop pressure pump designed to generate pressure to
15,000 psi (1,000 bar). This pump incorporates a dual-piston system which is ideal for filling large volume workload with the hand pump and providing smooth increase and decrease of pressure with the high pressure, fine adjust screw press. The 946 test pump incorporates an isolation valve which isolates the calibration volume from the check valve associated with the hand pump. Because the check valve can often be a source of leaks and maintenance, the isolation valve provides more stable measurements and reduces potential maintenance of the pump. Three hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The Additel 946 is an ideal comparison test pump for calibrating pressure measuring instruments such as test gauges, indicators or transducers.
FEATURES
Hand pump to fill large volume systems
Durable and Minimal Maintenance
Isolation valve provides stable pressures while reducing maintenance on the hand pump check valve.
Easy-to-use
15,000 psi (1,000 bar) can be generated easily with the dual-piston system.
Three hand-tight quick connectors
Allows easy connection and disconnection to the test pump without the need for PTFE tape or wrenches.
SPECIFICATIONS
Media: Mineral oil or deionized water. (Oil is default media liquid. Pump with water as media to be ordered specifically)
Generated Pressure Range
0 to 15,000 psi (1,000bar) gauge pressure
Material
Ram/adapters: SS
Body: SS, aluminum, Copper
Seals: Buna-N
Connection
Hand-tight connectors for both test gauge and reference gauge
Dimensions: Height: 6.9'' (175 mm)
Base: 17.9'' (455 mm) x 15.0'' (380 mm)
Weight: 28.7 lb (13 kg).
Warranty: 1 year
Piston volume
Fine adjust piston: 1.5ml (0.09 in
3
)
ORDERING INFORMATION
Model Number
ADT946 N
Optional Accessories
Model number
9202
Model
Pressure port type:
N -
1/4
NPT female
N2 - 1/2NPT female
B - 1/4BSP female
B2 - 1/2BSP female
M - M20X1.5 female
ADT102
ADT103
ADT-HTK
Accessories included
Mineral oil,1 bottle (250 ml)*
O-ring: 20 pcs
ADT946-MK
ADT100-946-HK
Manual: 1 pc
*When water media is not requested
Look us up on www.additel.com or call today (1)714-998-6899
Description
Oil, Mineral oil, 1 liter (1 quart)
Adapters and fittings, 1/4HP male to various male and female connectors
(25 pcs). More information shown on page 61.
Adapters and fittings, 1/4NPT (1/4BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.
Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT
(1/8NPT, 1/2NPT, 1/4BSP, or M20X1.5) female hand-tight quick connector. More information shown on page 63.
Maintenance kit for Additel 946 pump
Hose Kit, External Reservoir Expansion Hose Kit for ADT946
Additel 949
Hydraulic Ultra-high Pressure Test Pump
Generate 85% vacuum to 40,000 psi (2,800 bar) pressure
Minimal maintenance
Easy-to-use
Three pressure ports
OVERVIEW
The 949 Hydraulic Ultra-high Pressure Test Pump is a hand operated pressure pump designed to generate pressure up to 40,000 psi (2800 bar). With the patented screw press technology, high pressures can be easily generated, increased and decreased smoothly. A specially designed shut-off valve makes the pressure as stable as possible during calibration. With no non-returning valve, the 949 avoids the troublesome leakage issues that is usually experienced with hand pumps and allows for minimal maintenance. The 949 is an ideal comparison test pump for calibrating ultra-high pressure measuring instruments such as test gauges, indicators or transducers in the laboratory.
FEATURES
Generate Ultra-high Pressure
Generate pressure up to 40,000 psi (2,800 bar)
Durable and Minimal Maintenance
Patented screw press technology, without nonreturning valve inside that is usually used on troublesome hand pumps.
Easy-to-use
With the patented screw press technology, high pressures can be generated easily, as well as increased and decreased smoothly.
Extremely Low Leakage
Patented screw press technology replaces troublesome, check valves (non-returning valve) found in most hand pumps which practically eliminates leakage.
ORDERING INFORMATION
Model Number
ADT949
Model
AF
Pressure port type:
AF-Autoclave F-250-C female
B2-1/2BSP female
X-Customize
SPECIFICATIONS
Media: Oil
Pressure Range
85% vacuum to 40,000psi (2,800bar) positive pressure.
Material
Ram/adapters: SS
Body: SS, aluminum
Seals: Buna-N, PTFE, Copper Alloy
Reservoir capacity: 420 ml (25.6 in
3
)
Connection
Test Gauge Connection: Positional Autoclave
F-250-C, 9/16" - 18 UNF female
Reference Gauge Connection: Positional Autoclave
F-250-C, 9/16" - 18 UNF female
1/2BSP female and M20X1.5 female connections are available upon request.
Dimensions: Height: 9.1'' (230 mm)
Base: 20.5'' (520 mm) x 14.2'' (360 mm)
Weight: 35.2 lb (16 kg).
Warranty: 1 year
Piston volume
Low pressure piston: 30 ml (1.8 in
3
)
High pressure piston: 2.5 ml (0.15 in
3
)
Accessories included
Diethylhexyl Sebacate oil: 1 bottle (250 ml)
Manual: 1 pc
Optional Accessories
Model number
9201
ADT104
9908
ADT949-MK
Description
Oil, Diethylhexyl Sebacate, 1 liter (1 quart)
Adapters and fittings, 1/4HP male to various male and female connectors
(17 pcs). More information shown on page 63.
Carrying case for 936, 937, 938 or 949.
Maintenance kit for Additel 949 pump
Look us up on www.additel.com or call today (1)714-998-6899
57
Additel 959
Hydraulic Ultra-high Pressure Test Pump
Pressurize large-volume workload
Generate pressure to 40,000 psi (2,800 bar)
Increase and decrease pressure smoothly
Three pressure ports
58
OVERVIEW
The new Additel 959 Hydraulic Pressure Test Pump is a benchtop pressure pump designed to generate pressure to
40,000 psi (2,800 bar). This pump incorporates a dual-piston system which is ideal for filling large volume workload with the hand pump and providing smooth increase and decrease of pressure with the high pressure, fine adjust screw press. The 959 test pump incorporates an isolation valve which isolates the calibration volume from the check valve associated with the hand pump. Because the check valve can often be a source of leaks and maintenance, the isolation valve provides more stable measurements and reduces potential maintenance of the pump. The Additel 946 is an ideal comparison test pump for calibrating pressure measuring instruments such as test gauges, indicators or transducers.
FEATURES
Generate Ultra-high Pressure
Generate pressure up to 40,000 psi (2,800 bar)
Hand pump to fill large volume systems
Durable and Minimal Maintenance
Isolation valve provides stable pressures while reducing maintenance on the hand pump check valve
Easy-to-use
40,000 psi (2,800 bar) can be generated easily with the dual-piston system
SPECIFICATIONS
Media: Oil
Pressure Range
0 to 40,000psi (2,800bar) gauge pressure.
Material
Ram/adapters: SS
Body: SS, aluminum, Copper
Seals: Buna-N, PTFE, Copper Alloy, Aluminum Alloy
Reservoir capacity: 420 ml (25.6 in
3
)
Connection
Test Gauge Connection: Autoclave F-250-C, 9/16" -
18 UNF female
Reference Gauge Connection: Autoclave F-250-C,
9/16" - 18 UNF female
1/2BSP female and M20X1.5 female connections are available upon request
Dimensions: Height: 6.9'' (175 mm)
Base: 17.9'' (455 mm) x 15.0'' (380 mm)
Weight: 28.7 lb (13 kg).
Warranty: 1 year
Piston volume
Fine adjust piston: 1.5 ml (0.09 in
3
)
ORDERING INFORMATION
Model Number
ADT959 AF
Model
Pressure port type:
AF-Autoclave F-250-C female
B2-1/2BSP female
X-Customize
Accessories included
Diethylhexyl Sebacate oil: 1 bottle (250 ml)
Manual: 1 pc
Optional Accessories
Model number
9201
ADT104
ADT959-MK
ADT100-959-HK
Description
Oil, Diethylhexyl Sebacate, 1 liter (1 quart)
Adapters and fittings, 1/4HP male to various male and female connectors
(17 pcs). More information shown on page 63.
Maintenance kit for Additel 959 pump
Hose Kit, External Reservoir Expansion Hose Kit for ADT959
Look us up on www.additel.com or call today (1)714-998-6899
Pressure Manifolds
Additel 12X Series
The 12X series pressure manifolds are designed for expanding pressure test ports during pressure calibration. The
Additel 121 pressure manifold is used for pneumatic pressure calibration up to 3,000 psi (200bar), while the Additel 123 manifolds is compatible to hydraulic pressure applications up to 15,000 psi (1,000 bar). A filter is built-in with the 121 pneumatic pressure manifold to prevent contamination introduced by devices under test. There are four hand-tight quick connectors pre-installed on each manifold. Additel 12X series pressure manifolds allow you to connect without the use of wrenches or Teflon tape which increases your productivity when using calibration pumps, pressure controllers, dead weight testers, or piston gauges.
121 series Pressure Manifolds
Pneumatic, -15 psi to 3,000 psi (-1 to 200 bar)
Model Description
ADT121-N 1/4NPT male hose to four 1/4NPT female hand-tight quick connectors
ADT121-N2 1/2NPT male hose to four 1/2NPT female hand-tight quick connectors
ADT121-M M20×1.5 male hose to four M20×1.5 female hand-tight quick connectors
ADT121-B 1/4BSP male hose to four 1/4BSP female hand-tight quick connectors
ADT121-B2 1/2BSP male hose to four 1/2BSP female hand-tight quick connectors
123 series Pressure Manifolds
Hydraulic, -15 to 15,000 psi (-1 to 1,000 bar)
Model Description
ADT123-N 1/4NPT male hose to four 1/4NPT female hand-tight quick connectors
ADT123-N2 1/2NPT male hose to four 1/2NPT female hand-tight quick connectors
ADT123-M M20×1.5 male hose to four M20×1.5 female hand-tight quick connectors
ADT123-B 1/4BSP male hose to four 1/4BSP female hand-tight quick connectors
ADT123-B2 1/2BSP male hose to four 1/2BSP female hand-tight quick connectors
127 series Pressure Manifolds
Pneumatic, -15 to 3,500 psi (-1 to 250 bar)
Model Description
ADT127-N 1/4NPT male hose to three 1/4NPT female hand-tight quick connectors
ADT127-N2 1/2NPT male hose to three 1/2NPT female hand-tight quick connectors
ADT127-M M20×1.5 male hose to three M20×1.5 female hand-tight quick connectors
ADT127-B 1/4BSP male hose to three 1/4BSP female hand-tight quick connectors
ADT127-B2 1/2BSP male hose to three 1/2BSP female hand-tight quick connectors
Note: A test hose is included with every Additel 12X pressure manifold.
Look us up on www.additel.com or call today (1)714-998-6899
59
Filters
Additel 100 Series Filters
ADT100-FLT-600
600 psi (40 bar) Pneumatic Filter Specifications
Pressure range
-15 to 600 psi (-1.0 to 40 bar)
Filtering resolution
Operation temperature
Safety pressure
0.04 mm
-10°C to 50°C
Size
<720 psi (50 bar)
1.18 dia x 5 in (30 dia x 127 mm)
(size will vary based on adapters)
Outlet/Inlet port
Storage temperature
See ordering information
-20°C to 70°C
Material
304 SS
ADT100-FLT-10K
10,000 psi (700 bar) Hydraulic Filter Specifications
Pressure range
Filtering resolution
-15 to 10,00 psi (-1.0 to 700 bar)
0.07 mm
Operation temperature
-10°C to 50°C
Safety pressure
<12,000 psi (827 bar)
Size
Outlet/Inlet port
Storage temperature
Material
0.87 x 0.98 x 4 in (22 x 25 x 100 mm)
(size will vary based on adapters)
Comes with removable male and removable female adapter
-20°C to 70°C
304 SS
ORDERING INFORMATION
ADT100 600 N
Range:
600 -600 psi (40 bar)
10K-10,000 psi (700 bar)
Port type:
N-1/4NPT male and 1/4NPT female
N2-1/2NPT male and 1/2NPT female
B-1/4BSP male and 1/4BSP female
B2-1/2BSP male and 1/2BSP female
M-M20x1.5 male and M20x1.5 female
60
Look us up on www.additel.com or call today (1)714-998-6899
ADT100-FLT-10K
Inlet
Seals
Window
Seals
Drain valve
Filter
Seals
Outlet
ADT100-FLT-600
Pressure Hoses, Adapters and Fittings
Additel 102
(Designed for all pumps except Additel 949 pump)
Additel 102
ADT102
1/4NPT male to various connectors as follows (25 pcs, case included)
*1/2NPT male, 1/4BSP male, 1/2BSP male, M20X1.5 male are available per request.
Model
ADT100-NPTM4-BSPM8
ADT100-NPTM4-BSPM4
ADT100-NPTM4-BSPM2
ADT100-NPTM4-BSPM3
ADT100-NPTM4-M10M
ADT100-NPTM4-M14M
ADT100-NPTM4-M20M
ADT100-NPTM4-NPTM8
ADT100-NPTM4-NPTM4
ADT100-NPTM4-NPTM2
ADT100-NPTM4-NPTM3
ADT100-NPTM4-BSPF8
ADT100-NPTM4-BSPF4
ADT100-NPTM4-BSPF2
ADT100-NPTM4-BSPF3
ADT100-NPTM4-M10F
ADT100-NPTM4-M14F
ADT100-NPTM4-M20F
ADT100-NPTM4-NPTF8
ADT100-NPTM4-NPTF4
ADT100-NPTM4-NPTF2
ADT100-NPTM4-NPTF3
Description
Adapter, 1/4NPT male to 1/8BSP male
Adapter, 1/4NPT male to 1/4BSP male
Adapter, 1/4NPT male to 1/2BSP male
Adapter, 1/4NPT male to 3/8BSP male
Adapter, 1/4NPT male to M10X1.0 male
Adapter, 1/4NPT male to M14X1.5 male
Adapter, 1/4NPT male to M20X1.5 male
Adapter, 1/4NPT male to 1/8NPT male
Adapter, 1/4NPT male to 1/4NPT male
Adapter, 1/4NPT male to 1/2NPT male
Adapter, 1/4NPT male to 3/8NPT male
Adapter, 1/4NPT male to 1/8BSP female
Adapter, 1/4NPT male to 1/4BSP female
Adapter, 1/4NPT male to 1/2BSP female
Adapter, 1/4NPT male to 3/8BSP female
Adapter, 1/4NPT male to M10X1.0 female
Adapter, 1/4NPT male to M14X1.5 female
Adapter, 1/4NPT male to M20X1.5 female
Adapter, 1/4NPT male to 1/8NPT female
Adapter, 1/4NPT male to 1/4NPT female
Adapter, 1/4NPT male to 1/2NPT female
Adapter, 1/4NPT male to 3/8NPT female
Max Pressure
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
ADT100-HTK-NPTM4-NPTF4Q
Hose Test Kit, 5 feet flexible hose, 15,000 psi,
1/4NPT male to 1/4NPT female hand tight quick connector
15,000 psi
Picture
ADT100-NPTM4-NPTF4RQ
Adapter, 1/4NPT male to right angle 1/4NPT female hand-tight quick connector
15,000 psi
ADT100-NPTM4-BARB Adapter, 1/4NPT male to hose barb 150 psi
Don't need the entire kit? Order individual adapters with the above part numbers.
Look us up on www.additel.com or call today (1)714-998-6899
61
62
Pressure Hoses, Adapters and Fittings
Additel 103 Series
(Designed for all pumps except Additel 949 pump)
ADT103-NPT (Hand-tight quick connectors)
1/4NPT male to various hand-tight quick connectors (10pcs, case included)
Additel 103-NPT
Model Description
ADT100-NPTM4-NPTF8Q Adapters, 1/4NPT male to 1/8NPT female
ADT100-NPTM4-NPTF4Q Adapters, 1/4NPT male to 1/4NPT female
ADT100-NPTM4-NPTF2Q Adapters, 1/4NPT male to 1/2NPT female
ADT100-NPTM4-BSPF8Q Adapters, 1/4NPT male to 1/8BSP female
ADT100-NPTM4-BSPF4Q Adapters, 1/4NPT male to 1/4BSP female
ADT100-NPTM4-BSPF3Q Adapters, 1/4NPT male to 3/8BSP female
ADT100-NPTM4-BSPF2Q Adapters, 1/4NPT male to 1/2BSP female
ADT100-NPTM4-M10FQ Adapters, 1/4NPT male to M10×1.0 female
ADT100-NPTM4-M14FQ
ADT100-NPTM4-M20FQ
Adapters, 1/4NPT male to M14×1.5 female
Adapters, 1/4NPT male to M20×1.5 female
Max Pressure
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
Picture
ADT103-BSP (Hand-tight quick connectors)
1/4BSP male to various hand-tight quick connectors (10 pcs, case included)
Additel 103-BSP
Model Description
ADT100-BSPM4-NPTF8Q Adapter, 1/4BSP male to 1/8NPT female
ADT100-BSPM4-NPTF4Q Adapter, 1/4BSP male to 1/4NPT female
ADT100-BSPM4-NPTF2Q Adapter, 1/4BSP male to 1/2NPT female
ADT100-BSPM4-BSPF8Q Adapters, 1/4BSP male to 1/8BSP female
ADT100-BSPM4-BSPF4Q Adapters, 1/4BSP male to 1/4BSP female
ADT100-BSPM4-BSPF3Q Adapters, 1/4BSP male to 3/8BSP female
ADT100-BSPM4-BSPF2Q Adapters, 1/4BSP male to 1/2BSP female
ADT100-BSPM4-M10FQ
ADT100-BSPM4-M14FQ
ADT100-BSPM4-M20FQ
Adapters, 1/4BSP male to M10×1.0 female
Adapters, 1/4BSP male to M14×1.5 female
Adapters, 1/4BSP male to M20×1.5 female
Max Pressure
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
15,000 psi
Picture
ADT103-M20 (Hand-tight quick connectors)
M20
×
1.5 Male to various hand-tight quick connectors (10pcs, case included)
Additel 103-M20
Model
ADT100-M20M-NPTF8Q
ADT100-M20M-NPTF4Q
ADT100-M20M-NPTF2Q
ADT100-M20M-BSPF8Q
ADT100-M20M-BSPF4Q
ADT100-M20M-BSPF3Q
ADT100-M20M-BSPF2Q
ADT100-M20M-M10FQ
ADT100-M20M-M14FQ
ADT100-M20M-M20FQ
Description Max Pressure
Adapters, M20×1.5 Male to 1/8NPT female
Adapters, M20×1.5 Male to 1/4NPT female
Adapters, M20×1.5 Male to 1/2NPT female
Adapters, M20×1.5 Male to 1/8BSP female
15,000 psi
15,000 psi
15,000 psi
15,000 psi
Adapters, M20×1.5 Male to 1/4BSP female
Adapters, M20×1.5 Male to 3/8BSP female
15,000 psi
15,000 psi
Adapters, M20×1.5 Male to 1/2BSP female 15,000 psi
Adapters, M20×1.5 Male to M10×1.0 female 15,000 psi
Adapters, M20×1.5 Male to M14×1.5 female 15,000 psi
Adapters, M20×1.5 Male to M20×1.5 female 15,000 psi
Picture
Don't need the entire kit? Order individual adapters with the above part numbers.
Look us up on www.additel.com or call today (1)714-998-6899
Pressure Hoses, Adapters and Fittings
Additel 104 Hose Test Kits
ADT104-HP
1/4HP male (Autoclave M-250-C) to various connectors as follows (17pcs, case included);
(Designed for Additel 949 pump)
Model Description Max Pressure Picture
ADT100-HPM-M14F
ADT100-HPM-M20F
ADT100-HPM-BSPF4
ADT100-HPM-BSPF3
ADT100-HPM-BSPF2
ADT100-HPM-NPTF4
ADT100-HPM-NPTF2
ADT100-HPM-M14M
ADT100-HPM-M20M
ADT100-HPM-BSPM4
ADT100-HPM-BSPM3
ADT100-HPM-BSPM2
ADT100-HPM-NPTM4
ADT100-HPM-NPTM2
ADT100-HPM-HPM4
Adapter, 1/4HP male to M14X1.5 female
Adapter, 1/4HP male to M20X1.5 female
Adapter, 1/4HP male to 1/4BSP female
Adapter, 1/4HP male to 3/8BSP female
Adapter, 1/4HP male to 1/2BSP female
Adapter, 1/4HP male to 1/4NPT female
Adapter, 1/4HP male to 1/2NPT female
Adapter, 1/4HP male to M14X1.5 male
Adapter, 1/4HP male to M20X1.5 male
Adapter, 1/4HP male to 1/4BSP male
Adapter, 1/4HP male to 3/8BSP male
Adapter, 1/4HP male to 1/2BSP male
Adapter, 1/4HP male to 1/4NPT male
Adapter, 1/4HP male to 1/2NPT male
Adapter, 1/4HP male to 1/4HP male
40,000 psi
40,000 psi
40,000 psi
40,000 psi
40,000 psi
15,000 psi
15,000 psi
40,000 psi
40,000 psi
40,000 psi
40,000 psi
40,000 psi
15,000 psi
15,000 psi
40,000 psi
Additel 104
High Pressure Hose Test Kits
The Additel 100 series High Pressure Hose Test Kits are designed to extend your pressure calibrations to a convenient location to adapt from one pressure connection to another. Each test kit has 5 feet of flexible hose rated to 15,000 psi
(1,000 bar) which connects a male NPT, BSP, or Metric connector to a variety of female quick connectors. Additel's specially designed quick connectors allow for hand-tight connection without the need for wrenches or Teflon tape. The
Additel 100 series Hose Test Kits are a great accessory to any pressure pump or controller.
SPECIFICATIONS
Max pressure: 15,000 psi (1,000 bar)
Hose length: 5 ft (1.5 m)
Note: Custom lengths available by request.
ORDERING INFORMATION
Model Number
ADT100
HTK
NPTM4 NPTF4Q
Pressure port type:
NPTM4-1/4NPT male
NPTM2-1/2NPT male
BSPM4-1/4BSP male
BSPM2-1/2BSP male
M20M-M20x1.5 male
Pressure port type:
NPTF2Q-1/2NPT female quick connect
NPTF3Q-3/8NPT female quick connect
NPTF4Q-1/4NPT female quick connect
NPTF8Q-1/8NPT female quick connect
BSPF2Q-1/2BSP female quick connect
BSPF3Q-3/8BSP female quick connect
BSPF4Q-1/4BSP female quick connect
BSPF8Q-1/8BSP female quick connect
M20FQ-M20x1.5 female quick connect
Don't need the entire kit? Order individual adapters with the above part numbers.
Look us up on www.additel.com or call today (1)714-998-6899
63
Low Pressure Hose Test Kits
The Additel 100 series Low Pressure Hose Test Kits are designed to extend your pressure calibrations to a convenient location to adapt from one pressure connection to another. Each test kit has 5 feet of flexible hose rated to 1,000 psi (70 bar) which connects a male NPT, BSP, or Metric connector to a variety of female quick connectors. Additel's specially designed quick connectors allow for hand-tight connection without the need for wrenches or Teflon tape. The Additel
100 series Hose Test Kits are a great accessory to any pressure pump or controller.
SPECIFICATIONS
Max pressure: 1,000 psi (70 bar)
Hose length: 5 ft (1.5 m)
Connection: Each hose test kit is fitted with a female quick connect adapter on one end and a corresponding male adapter on the other.
(e.g. ADT100-HTK-1K-N has a 1/4 NPT female quick connect on one end and a 1/4 NPT male adapter on the other).
Note: Custom lengths available by request.
ORDERING INFORMATION
Model Number
ADT100
HTK
1K
Pressure port type:
N-1/4NPT male
N2-1/2NPT male
B-1/4BSP male
B2-1/2BSP male
M-M20x1.5 male
N
Don't need the entire kit? Order individual adapters with the above part numbers.
Software
Additel 95XX Series
ACal
ACal is a pressure calibration system running under network environment, it has a simple and friendly interface and supports the cooperation of Multiuser. This software assist with automated and semi automated calibrationsas well as a powerful instrument management features.
Main features
Supports multi-users and network environments
Calibration and asset management
Simple user interface
Scanning and printing of QR codes
User definable permissions and access levels
Preset test configurations
Can calibrate variety pressure instruments
Can calibrate several instruments at a time
Calibration planning and scheduling
Certificate management and creation
Certificate customization
64
Look us up on www.additel.com or call today (1)714-998-6899
9506 Additel/PCal
The Additel PCal Pressure Calibration software is used with the 681 pressure gauges, 672 calibrators, and any of the 9XX pumps.
Semi-automated calibration of pressure gauges, transmitters, transducers and other pressure devices can be performed.
Software can be used to manage reference standard instruments and devices under test, as well as generate and customize a calibration certificate.
9502 Additel/Log II & 9503 Additel/Log II Wireless
Additel/Log II is a real-time data logging and graphical software for the ADT681 series digital pressure gauges and the ADT672 series digital pressure calibrators.
Data can be recorded in real-time and for the ADT681 data logging version, recorded results can be uploaded.
After results are stored, they can be exported to a customizable report showing pressure and ambient temperature. Each real-time test can be tagged with a unique record name.
Additel/Log II Wireless is a real-time data logging and graphical software for the ADT680W series wireless digital pressure gauge. Data can be recorded in real-time and historical data in the gauge can be uploaded.
After results are stored, they can be exported to a customizable report showing pressure and ambient temperature. Each real-time test can be tagged with a unique record name.
The software lets you acquire data to your PC. You can choose to display the real-time or historical pressure measurement data in a table or in a graph.
9510 Additel/Cal
Task management software for the 22XA series multifunction process calibrators and the 761 series automated pressure calibrators.
Additel/Cal was designed specifically for task management of temperature and pressure calibration.
The main features include establishing a database of all reference and test instruments, maintaining a customer database, creating, uploading and downloading calibration tasks, generating a calibration report, and customizing the calibration certificate.
9500 Additel/Land & Additel/Land Wireless
With Additel/Land software, you may download test results stored in the internal memory of Additel calibrators to a PC, and export the results to an excel file. It is a free software package and can be downloaded at www.additel.com.
Look us up on www.additel.com or call today (1)714-998-6899
65
Precision Under Pressure
Phone: 714-998-6899 Fax: 714-998-6999 Email: [email protected]
Corporate Headquarters
2900 Saturn Street #B
Brea, CA 92821, USA
European Office
Holkebjerhvej 79
5250 Odense, Denmark
Salt Lake City Office
1364 West State Rd Suite 101
Pleasant Grove, UT, 84062, USA
Asia Office
5th Building, No. 3 Fengxiu Middle Road,
Haidian, Beijing 100094, China
advertisement
Related manuals
advertisement
Table of contents
- 5 Series Pressure Controller
- 13 Automated Pressure Calibrators
- 20 Digital Pressure Calibrators
- 23 Application notes
- 25 Digital Pressure Gauges
- 30 Application notes
- 33 Series Loop Calibrator
- 35 Multifunction Loop Calibrator
- 40 Intelligent Digital Pressure Modules
- 44 Low Pressure Test Pump
- 45 Low Pressure Test Pump
- 46 Handheld Pneumatic Pressure Test Pump
- 47 Pneumatic Pressure Test Pump
- 50 Pneumatic High Pressure Test Pump
- 51 Application notes
- 52 Pneumatic High Pressure Test Pump
- 53 Handheld Hydraulic Pressure Test Pump
- 54 Application notes
- 55 Hydraulic Pressure Test Pump
- 57 Hydraulic High Pressure Calibration Pump
- 60 Hydraulic High Pressure Calibration Pump