Pressure Calibration Equipment

Add to My manuals
70 Pages

advertisement

Pressure Calibration Equipment | Manualzz

n sstttrrru m e n nfffo @ o u o u

Precision under pressure

Pressure Calibration Equipment

Catalog 2016

Look us up on www.additel.com or call today (1)714-998-6899

1

ADDITEL CORPORATION

Additel Corporation is one of the leading worldwide providers of pressure calibration tools.

We are dedicated to designing, manufacturing, and delivering the highest quality test tools and portable calibrators for the process and calibration industries. For many years Additel has successfully developed pressure controlers, automated pressure calibrators, digital pressure test gauges, digital pressure calibrators, pressure test and calibration pumps, and multifunction process calibrators. Additel products are currently used in over 70 countries worldwide.

Product quality and customer service along with innovative engineering have been our top priorities and will continue to be our guiding principles going forward. We are committed to customer satisfaction through quality products, competitive pricing, unmatched services/ technical support and continued introduction of new and innovative products.

Phone: 714-998-6899 Fax: 714-998-6999 Email: [email protected]

Corporate Headquarters

Additel Corporation

2900 Saturn Street #B

Brea, CA 92821, USA

European Office

Additel Corporation

Holkebjerhvej 79

5250 Odense, Denmark

Salt Lake City Office

Additel Corporation

1314 West State Rd Suite 101

Pleasant Grove, UT 84062, USA

Asia Office

Additel Corporation

Bldg 5th, No. 3 Fengxiu Middle Road,

Haidian, Beijing, 100094, China

TABLE OF CONTENTS

Pressure Controllers

Additel 780 Series Pressure Controller....................................................01

Automated Pressure Calibrators

Automated Pressure Calibrators Selection Guide ................................... 08

Additel 761 Automated Pressure Calibrators...........................................09

Digital Pressure Calibrators / Gauges

Additel Digital Pressure Gauges Selection Guide ....................................14

Additel 672 Digital Pressure Calibrators.................................................. 16

Application notes......................................................................................19

Additel 681 Digital Pressure Gauges........................................................21

Additel 680 Digital Pressure Gauges........................................................24

Application notes......................................................................................26

Multifunction Process Calibrators

Multifunction Process Calibrators Selection Guide ...................................28

Additel 209 210 Series Loop Calibrator....................................................29

Additel 220 Multifunction Loop Calibrator.................................................31

Additel 221A 222A 223A Multifiction Documenting Process Calibrators..33

Digital Pressure Modules

Additel 160A Series Intelligent Digital Pressure Modules........................36

Pressure Test/Calibration Pumps

Pressure Test/Calibration Pumps Selection Guide ................................. 39

Additel 901 Low Pressure Test Pump..................................................... 40

Additel 912 Low Pressure Test Pump..................................................... 41

Additel 914 Handheld Pneumatic Pressure Test Pump.......................... 42

Additel 916 Pneumatic Pressure Test Pump........................................... 43

Additel 917 Pneumatic Pressure Test Pump........................................... 44

Additel 918 Pneumatic Pressure Test Pump........................................... 45

Additel 919A Pneumatic High Pressure Test Pump................................ 46

Application notes..................................................................................... 47

Additel 920 Pneumatic High Pressure Test Pump.................................. 48

Additel 925 Handheld Hydraulic Pressure Test Pump............................ 49

Application notes..................................................................................... 50

Additel 927 Hydraulic Pressure Test Pump............................................. 51

Additel 928 Hydraulic Pressure Test Pump............................................. 52

Additel 936 Hydraulic High Pressure Calibration Pump.......................... 53

Additel 937 Hydraulic High Pressure Calibration Pump.......................... 54

Additel 938 Hydraulic High Pressure Calibration Pump.......................... 55

Additel 946 Hydraulic High Pressure Calibration Pump...........................56

TABLE OF CONTENTS

Additel 949 Hydraulic Ultra-high Pressure Test Pump.............................57

Additel 959 Hydraulic Ultra-high Pressure Test Pump.............................58

Pressure Manifolds

....................................................................................59

Filters

.........................................................................................................60

Hoses, Adapters and Fittings

....................................................................61

Software

.................................................................................................... 64

Additel 780 Series Pressure Controller

Pressure ranges from vacuum to 3,000 psi (200 bar)

Removable interchangeable intelligent sensors

Precision accuracy of 0.005% of reading plus 0.005% of full scale

Standalone solution to 3,000 psi (200 bar), no gas bottle required when used with the Electric Pump and 3K Gas Booster

Standalone solution to 1,000 psi (70 bar), no gas bottle required when used with the Electric Pump

Standard model accuracy of 0.02% of full scale

External pressure modules to 3,000 psi (200 bar)

WiFi enabled communications

Fully temperature compensated accuracy over 0°C to 50°C

HART Communication and Profibus PA

Large 7” color touch screen display

Control stability of 0.003%FS

Built-in barometer

Easy-to-use icon based user interface

OVERVIEW

For years, we’ve provided the most durable, accurate, quality pressure calibration products for field applications. The Additel 780 series controller incorporates the same durability, accuracy, and quality into a new bench top controller packed with features and functionality that is remarkably easy to use. The Additel 780 series offers two base ranges: to 1,000 psi (70 bar) and to 3,000 psi (200 bar). The base range establishes the maximum controlling range of the controller. Each configuration includes a control sensor which is preselected to the sensor range best suited for your application. External and internal sensors can be used which allows for expanded range and accuracy capability in the future.

There are also two controller types that can be selected: the Additel 780S is the standard controller option without any measurement capability. The Additel 780 has expanded functionality including electrical measurement and HART and Profibus PA communication.

Look us up on www.additel.com or call today (1)714-998-6899

01

MODULAR DESIGN

Each unit comes with one Intelligent Pressure Module configured to the many range offerings provided. Standard accuracy sensors (ADT160A-CPXXX) are silicone pressure sensors with a 1 year accuracy of 0.02% FS. The precision quartz based sensors improve the 1 year accuracy specification to 0.005% of reading + 0.005% FS. Each sensor has been specially aged, tested and screened before assembly. After assembly each sensor is temperature compensated over the range of 0°C to 50°C. The Additel 780 series allows for one internal pressure sensor and one external pressure sensor. The modular design of this unit provides for interchangeability of both the internal and external sensors with other

Intelligent Pressure Modules.

In addition to the Intelligent Pressure Modules, the Additel 780 series has a built in barometric sensor. This allows for switching between gauge pressures to absolute pressures.

STANDALONE SOLUTION

Typical pressure controllers will require a nitrogen bottle for the gas supply which make it difficult to move the controller around without having to move or connect to another bottle.

The Additel 780 series is unique in that with the optional electric pump, you can generate pressures to 1,000 psi (70 bar) without the need of a gas bottle. Add the booster to the configuration and 3,000 psi (200 bar) is achievable with the Additel 780 controller series.

PROCESS FUNCTIONALITY (excl ADT780S versions)

The 780 Series Pressure Controller is considered to handle a very wide range of applications which may normally require a pressure calibrator. Built-in capability, includes current and voltage measurement capability, 24 volt loop power, HART

® switch measurement capability, and much more.

and Profibus PA communication,

MEASUREMENT SPECIFICATIONS

Specification

Pressure range

Control stability

Precision

(includes 1 year stability)

ADT780-1K

-14.5 to 1,000 psi (-0.95 to 70 bar)

0.003% FS (stability based on % FS of control sensor range)

See pressure range table

ADT780-3K

-14.5 to 3,000 psi (-0.95 to 200 bar)

[1]

1 Year stability

0.01% FS standard accuracy sensors

0.005% FS precision accuracy sensors

Media

Over-range indication

Resolution

Pressure type

Clean gas

103% to 120% (based on sensor)

4, 5, 6, or 7 digits (user selectable)

[2]

Gauge, Absolute

Warm up time

15 minutes

Typical pressure settling time

(within 0.003%FS)

20 seconds (10%FS pressure change assuming 50 mL test volume)

Measurement units

Pa, hPa, kPa, MPa, bar, mbar, psi, mmHg@0°C,cmHg@0°C, mHg@0°C, inHg@0°C, inH mH

2

2

O@4°C, mmH

O@20°C, kg/m

2

2

O@4°C, cmH

2

, kg/cm

2

O@4°C, mH

2

O@4°C, mmH

, mtorr, torr, atm, lb/ft

2

2

O@20°C, cmH

, tsi, user selectable

2

O@20°C,

Minimum control pressure

[3]

0.0001 psi 0.001 psi

[1] Gas booster or HP gas supply required to reach 3,000 psi (200 bar). Booster ordered separately.

[2] 7 digit resolution for precision model only.

[3] Dependent on pressure module.

02

Look us up on www.additel.com or call today (1)714-998-6899

BAROMETRIC MEASUREMENT SPECIFICATION

Sensor/Mode

ADT160-02-CPXX

Gauge

N/A

Absolute

40 Pa

[1]

ADT160-01-APXXQ 3 Pa

[2]

N/A

Barometer range (60~110)kPa, the accuracy is 40 Pa (11 Pa is optional)

[1] 40 Pa uncertainty (k=2) includes calibration uncertainty, linearity, and long term stability (<30 Pa per year). Barometer range of 60 to 120 kPa.

[2] Combined linearity, hysteresis, and repeatability. Add 3 Pa when used in gauge mode. When using the ADT160-01-APXXQ sensors with the

ADT780 controller in gauge mode, regular zeroing will realign the barometric reading to provide the most accurate result.

ELECTRICAL MEASURE SPECIFICATIONS

[1]

Specification Range Resolution Accuracy

-30 to 30 V 0.1 mV ±0.01% rdg + 1.5 mV

Volts DC

Current DC

-300 to 300 mV

-30 to 30 mA

1 μV

0.1 μA

±0.01% rdg + 15 μV

±0.01% rdg + 1.5 μA

Switch test

If the switch has detected voltage, the range is from 3 – 24 V

DC 24V output

[1] Not available in ADT780S versions

24V ± 0.24V, max 30 mA

PHYSICAL SPECIFICATIONS

Specification

Power

Pressure ports

Storage temperature

ADT780-1K & ADT780-3K

100 to 240V, 50/60 Hz

G1/8 F

-20°C to 70°C

Operating environment

0-90% RH non-condensing

Display

Weight

7 inch (17.8 cm) color, touch screen display

33 lbs (15 kg)

Dimensions (DWH)

Mounting

16.5 x 17.3 x 5.2 inch (419 x 440 x 132 mm)

Standard desktop, optional rack mount kit

Shock

Vibration

4G

1G 10Hz~500Hz

OTHER SPECIFICATIONS

WiFi specifications

Vent

Communications

Stability indicator

Typical slew rate

Operating modes

Display modes

Localization

Conformity

802.11 b, g, and n

Front panel vent and safety release button (only for 780S)

RS232,USB,LAN,WIFI

User selectable

Typically 20 seconds

Control, measure, and vent

Controller – show pressure indication and control

Calibrator – shows pressure indication, control, and electrical measurement (excl ADT780S)

English, Chinese (simplified), German, Spanish, French, Italian, Portuguese, Russian, Japanese

CE

Calibration certification

NIST-traceable certificate of calibration with data included

Warranty

1 year

Look us up on www.additel.com or call today (1)714-998-6899

03

STANDARD ACCESSORIES

ADT127-X External

Manifold

1 pc

Manifold connection cable

1 pc

Power adapter

1 pc

OPTIONAL ACCESSORIES

ADT160A

Pressure modules (see module information)

ADT121-X

External pneumatic pressure manifold, 3,000 psi (200 bar), four hand-tight quick connectors

ADT780-3K-BST

3,000 psi (200 bar) gas booster

9022 Test leads

2 sets (4 pc)

ADT780-1K-EPUMP

1,000 psi (70 bar) electrical pump

9020 Short circuit cable

1 set (2 pc)

ADT780-VACPUMP

Vacuum pump

9060 Pressure module connection cable

1 pc

9050

RS232 to USB adapter

Adapter set (adapters to fit the ADT78X port to male fittings)

1 set

(2 pcs G1/8M to G1/4M, 2 pcs

G1/8M to Festo, release valve)

CD Manual

NIST traceable certificate

O-rings

Vacuum/Vent tubing

1 pc

1 pc

3 types

2 pc

ADT100-FLT-600

Liquid trap

9912-780

Shipment case for the ADT780

Controller

9506 Additel/PCal

Manual calibration software

9530 Additel/ACal

Automated calibration software,

Task and asset management

9245-780

ADT100-780-Kit

Rack mount kit

Adapter set, total 9 pcs.

G1/8 M to 1/4NPT M (3 pcs)

G1/8 M to G1/4 M (3 pcs)

G1/8 M to M20x1.5 M (3 pcs)

ADT780 ORDERING INFORMATION

(Controller without 3K psi booster)

Model Number

ADT780 3k CP300 N HABP

04

Model 780

Model 780S

Maxmum Range:

3K-3,000 psi (200 bar)

1K-1,000 psi (70 bar)

Pressure range:

See range table

Look us up on www.additel.com or call today (1)714-998-6899

High Accuracy Barometer

Manifold port type:

N-1/4NPT male

N2-1/2NPT male

B-1/4BSP male

B2-1/2BSP male

M-M20x1.5 male

ADT160A Intelligent Digital Pressure Modules

Gauge pressure Differential pressure

SPECIFICATIONS

Pressure Range

P/N psia

Precision Quartz Sensors

[1] bar.a

Media Accuracy

Pressure Rating

Burst Over Pressure

Suggested

Controller

Compatibility

Internal/

External

Use

AP45Q

AP100Q

AP400Q

AP500Q

AP1KQ

AP2KQ

AP3KQ

0 to 45

0 to 100

0 to 400

0 to 500

0 to 1,000

0 to 2,000

0 to 3,000

Standard Pressure Sensors

3.0

7.0

28

35

70

140

200

G

G

G

G

G

G

G

0.005% rdg + 0.005% FS

0.005% rdg + 0.005% FS

0.005% rdg + 0.005% FS

0.005% rdg + 0.005% FS

0.005% rdg + 0.005% FS

0.005% rdg + 0.005% FS

0.005% rdg + 0.005% FS

3x

3x

3x

3x

3x

3x

3x

1.2x

1.2x

1.2x

1.03x

1.1x

1.1x

1.1x

ADT780-1K only

ADT780-1K only

Both

Both

Both

ADT780-3K only

ADT780-3K only

Both

Both

Both

Both

Both

Both

Both

P/N

Pressure Range psig bar.g

Media Accuracy

Pressure Rating

Burst Over Pressure

Suggested

Controller

Compatibility

ADT780-1K only

Internal/

External

Use

Both

CP10

CP15

±10

±15

±0.7

±1.0

G

G

0.02% FS

0.02% FS

3x

3x

1.2x

1.2x

ADT780-1K only Both

CP30

CP50

-15 to 30

-15 to 50

-1 to 2.0

-1 to 3.5

G

G

0.02% FS

0.02% FS

3x

3x

1.2x

1.2x

ADT780-1K only

ADT780-1K only

Both

Both

CP100

CP300

-15 to 100

-15 to 300

-1 to 7.0

-1 to 20

G,L

G,L

0.02% FS

0.02% FS

3x

3x

1.2x

1.2x

ADT780-1K only

Both

Both

Both

CP500

CP600

-15 to 500

-15 to 600

-1 to 35

-1 to 40

G,L

G,L

0.02% FS

0.02% FS

3x

3x

1.2x

1.2x

Both

Both

Both

Both

CP1K

CP2K

-15 to 1,000

-15 to 2000

-1 to 70

-1 to 140

G,L

G,L

0.02% FS

0.02% FS

3x

3x

1.2x

1.2x

Both

ADT780-3K only

Both

Both

CP3K

CP5K

-15 to 3,000

-15 to 5000

-1 to 200

-1 to 350

G,L

G,L

0.02% FS

0.02% FS

3x

3x

1.2x

1.2x

ADT780-3K only

N/A

Both

External

CP10K

-15 to 10,000 -1 to 700 G,L 0.02% FS 2x 1.2x

N/A External

[1] Contact Additel for other range options.

**Low pressure sensors (ADT160A-XX-DPX) available for low pressure and differential pressure measurement. Also available for low pressure control (gauge mode only). Ranges from ±1 inH

2

0 (2.5 mbar) to 300 inH

2

O (700 mbar).

Look us up on www.additel.com or call today (1)714-998-6899

05

SENSOR SPECIFICATIONS

Standard Accuracy

CPXXX AP3KQ AP1KQ

Precision Accuracy

AP100Q

Temperature compensation

Operating temperature

-10°C to 50°C (14°F to 122°F)

-10°C to 50°C (14°F to 122°F)

0°C to 50°C (32°F to 122°F)

0°C to 50°C (32°F to 122°F)

Storage temperature

-20°C to 70°C (-4°F to 158°F) -20°C to 70°C (-4°F to 158°F)

Relative humidity

Pressure connections

(for external use only)

Enclosure

(for external use only)

Dimensions (Dia x H)

95% RH

1/4NPT, 1/4BSP, 1/2BSP, M20x15

SS enclosure

95% RH

1/4NPT, 1/4BSP, 1/2BSP, M20x15

33 mm x 123 mm (1.3” x 4.84”) 44 mm x 220mm (1.7” x 8.7”)

Weight

0.4 kg (0.99 lb)

[1] Internal sensors used to go inside the ADT780 need to have a M20 connection and connection kit.

0.8 kg (1.8 lb)

SS enclosure

60 mm x 190 mm (2.4” x7.5”)

1.2 kg (2.6 lb)

ORDERING INFORMATION

Model Number

ADT160A 01 CP300 PSI N

Model

Range type:

PSI - range by psi

BAR - range by bar

Accuracy:

01 – 0.005% rdg + 0.005% FS

02 – 0.02% FS

Pressure range:

See range table

External pressure port type:

N - 1/4NPT male

N2 - 1/2NPT male

B - 1/4BSP male

B2 - 1/2BSP male

M - M20x1.5 male

06

Look us up on www.additel.com or call today (1)714-998-6899

Electric Pump and Booster

Additel 780-1K-EPUMP

ELECTRIC PUMP

Generates Vacuum to 1,000 psi (70 bar)

Built-in filter and liquid trap

1,000 psi (70 bar) Electric Pump Specifications

Pressure range

-13.5 to 1,080 psi (-0.95 to 75 bar)

Weight

Size(WHD)

69.6 lbs (31.6 kg)

17.3 X 9.3 X 21.7 inch (440 X 235X 550 mm)

Power

Media

100 to 240V

Air

Outlet port

Storage temperature

G1/8F

-20°C to 70°C

Operating environment

0-90% RH non-condensing

Mounting

Standard desktop, optional rack mount

Control operation

2 LED displays with pressure limit settings

Typical max pressure time

Approx 2 min with ADT780 Controller

Additel 780-3K-BST

BOOSTER

3,000 psi (200 bar) Gas Booster Specifications

Minimum inlet pressure

300 psi (20 bar)

Out pressure range

300 to 3,600 psi (250 bar)

Inlet flow rate

Size (WHD)

500ml/min

17.8 X 7.3 X 23.9 inch (451 X 185 X 607 mm)

Weight

Power

74 lbs (33.6 kg)

100 to 240V

Supply media

Nitrogen or clean gas

Look us up on www.additel.com or call today (1)714-998-6899

07

Additel 761

Automated Pressure Calibrators

Selection Guide

Model

Features

Pressure

Range

761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP

-25 to 25 mbar

(-10 to 10 inH

2

O)

-0.95 to 1 bar

(-13.5 to 15 psi)

-0.95 to 7 bar

(-13.5 to 100 psi)

0.05 to 8 bar.a

(1.2 to 115 psi.a)

-0.90 to 25 bar

(-13 to 375 psi)

0.1 to 26 bar.a

(1.7 to 390 psi.a)

-0.90 to 40 bar

(-13 to 600 psi)

0.1 to 41 bar.a

(1.7 to 615 psi.a)

100 to

1200 hPa

Pressure

Module 1

-2.5 to 2.5 mbar

(-1 to 1 inH

2

O)

-25 to 25 mbar

(-10 to 10 inH

2

O)

-0.95 to 2.5 bar

(-13.5 to 35 psi)

0.05 to 3.5 bar.a

(1.2 to 50 psi.a)

-0.9 to 2.5 bar

(-13 to 35 psi)

0.1 to 3.5 bar.a

(1.7 to 50 psi.a)

-0.9 to 2.5 bar

(-13 to 35 psi)

0.1 to 3.5 bar.a

(1.7 to 50 psi.a)

100 to

1200 hPa

Pressure

Module 2

Differential

Pressure

Gauge Pressure

Absolute

Pressure

Barometric

Pressure

Temperature

Compensated

Built-in Electrial

Pump

-25 to 25 mbar

(-10 to 10 inH

2

O)

-0.95 to 1 bar

(-13.5 to 15 psi)

Built-in Filter

Built-in Liquid

Trap

Source 0 to

22mA

Measure mA

or V

Measure external pressure module

24V Loop power

Pressure switch test

HART

Communication

Documenting

0 to 7 bar

(0 to 100 psi)

0.05 to 8 bar.a

(1.2 to 115 psi.a)

0 to 25 bar

(0 to 375 psi)

0.1 to 26 bar.a

(1.7 to 390 psi.a)

0 to 40 bar

(0 to 600 psi)

0.1 to 41 bar.a

(1.7 to 615 psi.a)

NA

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

08

Look us up on www.additel.com or call today (1)714-998-6899

Additel 761

Automated Pressure Calibrators

Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inH

2

O)

0.02%FS accuracy

Dual pressure modules

Built-in filter and liquid trap with venting system prevents contamination of the calibrator

Portable (12.4 lb)

OVERVIEW

With a built-in high performance electronic pump and precision pressure controller, the 761 series portable automated pressure calibrators provide a turnkey solution for calibration of gauges, transmitters, and switches both in the field and in the laboratory.

In a portable package, this calibrator can automatically generate pressures from 90% vacuum to 600 psi (40 bar) with 0.005% FS pressure control stability and 0.02% FS accuracy. To improve the calibrator accuracy, two pressure modules with differing ranges are built-in and integrated with the internal pump and controller.

The 761-LLP is specially designed for low pressure calibration, and pressures can be set to as low as 0.01 Pa (0.00004 inH

(0.0002 inH

2

O).

2

O) with a control stability better than 0.05 Pa

The 761-BP is designed for barometric gauge calibration. With a quartz pressure sensor, the accuracy of 761-BP can achieve 0.01%FS accuracy.

With optional external pressure modules (160A series), the 761 can measure pressures up to 10,000 psi (700 bar) with 0.02%FS accuracy. In addition to the pressure generation, control, and measurement capabilities, the 761 also features

HART communication capability, supplies 24V loop power, and reads the current or voltage produced by the pressure transducers. The 761 is a state of the art automated pressure calibrator which brings automated pressure calibration to the field.

Look us up on www.additel.com or call today (1)714-998-6899

09

FEATURES

Pressure Range

Pressure generated by built-in pump and controlled automatically from 90% vacuum to 600 psi (40 bar)

Pressure measured with external pressure modules

(160A series) to 10,000 psi (700 bar)

Accuracy (Fully temperature compensated)

0.02%FS

0.05%FS (ADT761-LLP)

0.01%FS (ADT761-BP)

Control Stability

<0.005%FS

ADT761-LLP: < 0.05 Pa (0.0002 inH

2

O)

Contamination prevention system

Built-in filter and liquid trap with venting system prevent contamination of the calibrator

Solid particles can be blocked by built-in filter

A small amount of liquid can be collected by the builtin liquid trap

Both solid particles and liquid can be blown out through the venting system

Automation and Test Program

Fully Automated pressure calibration

Task preset and auto run

Auto step

Easy to Use

User friendly interface

Intuitive icon driven menu structure

Sourcing and Measuring electrical signals

Measure mA with 0.01% RD + 1.5μA accuracy

Measure V with 0.01% RD + 1.5mV accuracy

Source/sink 0 to 22mA current

24 VDC loop power supplied to pressure transmitter during test

Automated switch test

Misuse Protection

Up to 30V misuse protection on any two sockets

Display

7" LCD color screen (800X480)

Documenting and on-demand logging

Task management capability

Internal memory stores 200 tasks

Download tasks and upload results

900 snapshots

HART Communication capability

Support HART instrumentation

Pressure output rate

2.4 liters/minute

Rechargeable battery:

Rechargeable battery with up to 8 hours operation between charges

Leak testing:

Apply leak test to an external pressure system to determine the magnitude of pressure variations due to leaks

Pipeline Protection: Special design the pipeline layout to avoid possible blockage and leakage

Portable: Only 12.4 lb

Multi Lingual Interface

English, German, French, Italian, Spanish, Portuguese,

Simplified Chinese

(Traditional Chinese, Japanese and Russian are available per request)

NIST Traceable: NIST traceable calibration with data

(included)

10

Look us up on www.additel.com or call today (1)714-998-6899

SPECIFICATIONS

Control Stability

<0.005%FS

[1]

;

ADT761-LLP: < 0.05 Pa (0.0002 inH

2

O)

Pressure Connections

Pressure connection: ADT761-L/M/H/LA/MA/HA

One ADT100-761 Hose Test Kit with quick connector

1/8 BSP Female on calibrator

Two 1/4NPT(or 1/2NPT, 1/4BSP, 1/2BSP, M20×1.5) female hand-tight connectors on the external pressure manifold

Pressure connection: ADT761-LLP/BP

Stainless steel hose barb fitting

External Pressure Module Connection

Accepts Intelligent Pressure Module

Electrical Connection

0.156 inch (Ø4mm) banana sockets

Documenting and on-demand logging

Task management capability

Internal memory stores 200 tasks

Download tasks and upload results

Display

7" LCD color screen (800×480)

Display rate: 5 readings per second

Resolution 4, 5 or 6 digit, user selectable

Pressure Units

Pa, kPa, MPa, psi, bar, mbar, inH mmH

2

O@4°C, inH

2

O@20°C, mmH inHg@0°C, mmHg@0°C, kgf/cm

2

BP)

2

O@4°C,

2

O@20°C,

, and hPa (ADT761-

Pump life: >100,000 cycles

Power

Battery: Rechargeable Li-ion Polymer battery (included)

Li-Battery working time: ~8 hours

Recharge time: ~3 hours

External Power: 110/220V Power adapter (DC 27 V)

(Included)

Environmental Specification:

Operating temperature: 32°F to 122°F (0°C to 50°C)

Compensated Temperature: 32°F to 122°F (0°C to

50°C)

Storage temperature: -20°C to 60°C (-4°F to 120°F)

Humidity: <90%, non-condensing

European Compliance: CE Marked

Communication

RS232 (DB9/F, environmentally sealed)

Baud rate: 2400, 4800, 9600, 19200, 38400, 57600,

115200

Data length: 7 Bits, 8 Bits

Stop bit: 1 Bit, 2 Bits

Address: from 1 to 121

Dimension

11.65 X 7.32 X 7.09 in (296 X186 X180 mm)

Weight: 12.4 to 16.3 lb (5.6 to 7.4 kg)

Warranty: 18 months

[1] FS specification applies to the span of the range

Task Manual

Built-in User's Manual

Pressure gauge / transmitter / switch calibration

Documenting

Look us up on www.additel.com or call today (1)714-998-6899

11

Additel 761

Automated Pressure Calibrators

SPECIFICATIONS

Pressure Ranges

Type

Low/Differential

Pressure

Gauge Pressure

Gauge/Absolute

Pressure

Model

ADT761-LLP

ADT761-D

ADT761-L

ADT761-M

ADT761-H

ADT761-LA

ADT761-MA

ADT761-HA

Pressure Range

-25 to 25 mbar

(-10 to 10 inH

2

O)

-0.95 to 1 bar

(-13.5 to 15 psi)

-0.95 to 7 bar

(-13.5 to 100 psi)

-0.90 to 25 bar

(-13 to 375 psi)

-0.90 to 40 bar

(-13 to 600 psi)

-0.95 to 7 bar

(-13.5 to 100 psi)

0.05 to 8 bar.a

(1.2 to 115 psi.a)

-0.90 to 25 bar

(-13 to 375 psi)

0.1 to 26 bar.a

(1.7 to 390 psi.a)

-0.90 to 40 bar

(-13 to 600 psi)

0.1 to 41 bar.a

(1.7 to 615 psi.a)

100 to 1,200 hPa 100 to 1,200 hPa

Pressure Module 1

Range Accuracy

[1]

-2.5 to 2.5 mbar

(-1 to 1 inH

2

O)

-25 to 25 mbar

(-10 to 10 inH

2

O)

-0.95 to 2.5 bar

(-13.5 to 35 psi)

-0.9 to 2.5 bar

(-13 to 35 psi)

-0.9 to 2.5 bar

(-13 to 35 psi)

-0.95 to 2.5 bar

(-13.5 to 35 psi)

0.05 to 3.5 bar.a

(1.2 to 50 psi.a)

-0.9 to 2.5 bar

(-13 to 35 psi)

0.1 to 3.5 bar.a

(1.7 to 50 psi.a)

-0.9 to 2.5 bar

(-13 to 35 psi)

0.1 to 3.5 bar.a

(1.7 to 50 psi.a)

0.05%FS

[2]

0.05%FS

[2]

0.02%FS

0.02%FS

0.02%FS

0.02%FS

0.03%FS

0.02%FS

0.03%FS

0.02%FS

0.03%FS

0.01%FS

Pressure Module 2

Range Accuracy

[1]

-25 to 25 mbar

(-10 to 10 inH

2

O)

-0.95 to 1 bar

(-13.5 to 15 psi)

0 to 7 bar

(0 to 100 psi)

0 to 25 bar

(0 to 375 psi)

0 to 40 bar

(0 to 600 psi)

-0.95 to 7 bar

(-13.5 to 100 psi)

0.05 to 8 bar.a

(1.2 to 115 psi.a)

-0.9 to 25 bar

(-13 to 375 psi)

0.1 to 26 bar.a

(1.7 to 390 psi.a)

-0.9 to 40 bar

(-13 to 600 psi)

0.1 to 41 bar.a

(1.7 to 615 psi.a)

0.05%FS

[2]

0.02%FS

0.02%FS

0.02%FS

0.02%FS

0.02%FS

0.025%FS

0.02%FS

0.025%FS

0.02%FS

0.025%FS

NA NA Barometric pressure ADT761-BP

[1] One year accuracy (including yearly stability). FS specification applies to the span of the module range.

[2] 0.05% FS accuracy (including months stability). One year accuracy is 0.05% FS calibration accuracy combined with 0.05% FS one year stability.

* Additel 761 calibrators support 160A series intelligent digital pressure modules that are available for gauge, vacuum and absolute pressure from -15 psi to 10,000 psi (-1 bar to 700 bar). Accuracy from 0.02%FS includes operation over 14°F to 122°F (-10°C to 50°C), one year stability and calibration uncertainty. For detailed specification refer to 160A series pressure modules datasheet.

Electrical Measurement and Source Accuracy

Voltage Measurement

Current Measurement

Current Source

Switch Test

DC 24V output

Range Resolution Accuracy

±30.0000V

±30.0000mA

0.000 to 22.000mA

0.1mV

0.1μA

1μA

±(0.01%RD + 1.5mV)

±(0.01%RD + 1.5μA)

±(0.02%RD + 2.2μA)

If the switch has detective Voltage, the range is from 3V to 24V

24V ± 0.5V, max: 50mA

12

Look us up on www.additel.com or call today (1)714-998-6899

Additel 761

Automated Pressure Calibrators

ORDERING INFORMATION

Model Number

ADT761 L N

Pressure range:

See pressure range table.

Pressure port type on External

Pressure Manifold:

N - 1/4NPT female

N2 - 1/2NPT female

B - 1/4BSP female

B2 - 1/2BSP female

M - M20X1.5 female

Accessories (included)

External Pressure

Manifold (ADT106)

(Except 761-LLP)

9818

110V/220V external

Power adapter

9722

Chargeable Li-ion battery

9022

Test Leads for calibrator

9020

Short circuit cable

9907

Carrying case for 761 calibrator and accessory

9060

Pressure module connection cable

9240

DP gauge holder, rubber

(Only for ADT761-LLP)

ADT100-761

(Except 761-LLP)

O-rings(Except 761-LLP)

1 pc

1 pc

1 pc

2 sets

(4 pcs)

1 set

(2 pcs)

1 pc

1 pc

1 pc

1 pc

Manual

20 pcs

1 pc

Allen wrench 1 set

ADT100-761Hose

(Except 761-LLP: 2 pcs)

NIST traceable calibration certificate

1 pcs

1 pc

* Additel/Land software could be downloaded for free at www.additel.com

Optional Accessories

Model Number

ADT100-761-N4

Description

Hose Test Kit, 5 feet flexible hose, 0.156"

(Ø4mm) tube to 1/4NPT hand-tight quick connector

ADT100-761-B4

ADT106-N

ADT106-B

ADT106-M

Hose Test Kit, 5 feet flexible hose, 0.156"

(Ø4mm) tube to 1/4BSP hand-tight quick connector

External Pressure

Manifold (with two

1/4NPT hand-tight quick connectors)

External Pressure

Manifold (with two

1/4BSP hand-tight quick connectors)

External Pressure

Manifold (with two

M20X1.5 hand-tight quick connectors)

ADT160A

Pressure modules

(please check Additel

160A datasheet)

9050

USB to RS232 (DB9/M)

Adapter

9060

Pressure module connection cable

9510

Additel/Cal task management software

Picture

ADT100-761Hose ADT761 hose, 5 feet

Look us up on www.additel.com or call today (1)714-998-6899

13

14

Additel Pressure Gauge

Selection Guide

Series

Feature

ADT672 Series

Digital Pressure Calibrator

ADT681 Series

Digital Pressure Gauge

ADT680 Series

Digital Pressure Gauge

Gauge Pressure

Compound Pressure

Absolute Pressure

Differential Pressure

Accuracy Classes

0.02% & 0.05%FS

15K & 20K psi: 0.05%FS

> 20K psi: 0.1%FS

0.02%, 0.05%, 0.1%, & 0.2%FS & 0.1%RD

15K & 20K psi: 0.05%, 0.1%, 0.2%FS &

0.1%RD

>20K psi: 0.1% & 0.2%FS

0.05%, 0.1%, & 0.25%FS

> 20K psi: 0.1% & 0.25%FS

Digital Display

Analog Display (Fan-Shaped

Indication)

Fully Temperature Compensation from -10°C to 50°C

Resolution

6-Digit Resolution

5-Digit Resolution

Selectable Pressure Units

Backlight

Over Pressure Indication

IS Certification (optional – not available for panel mount)

IP67 Certification

Panel Mount (optional)

Communication

Wireless

Data Logging

Min/Max

Built-in Leak Test

HART Communication

Measure mA and V

24V Loop Power

Switch Test

NIST-Traceable Certificate of

Calibration

Power

11

11

Optional

Rechargeable battery 9V battery (120/220V adapter is optional)

Series

Pressure Range

Pressure psi bar

Media

Gauge

V15

GP5

GP10

-15 to 0

0 to 5

0 to 10

-1 to 0

0 to 0.35

0 to 0.7

G

G

G

GP15

GP30

GP50

GP100

0 to 15

0 to 30

0 to 50

0 to 100

0 to 1

0 to 2

0 to 3.5

0 to 7

G, L

G, L

G, L

G, L

GP300

0 to 300 0 to 10 G, L

GP500

0 to 500 0 to 35 G, L

Look us up on www.additel.com or call today (1)714-998-6899

ADT672 Series

Digital Pressure Calibrator

ADT681 Series

Digital Pressure Gauge

19

680W only

680W only

2AA batteries

ADT680 Series

Digital Pressure Gauge

Series

Pressure

Pressure Range

Compound

CP2

CP5

CP10

CP15

CP30

CP100

CP300

Absolute

AP5

AP10

AP15

AP30

AP50

AP100

AP300

AP500

AP1K

AP3K

GP600

GP1K

GP2K

GP3K

GP5K

GP10K

GP15K

GP20K

GP25K

GP30K

GP36K

GP40K psi

0 to 600

0 to 1K

0 to 2K

0 to 3K

0 to 5K

0 to 10K

0 to 15K

0 to 20K

0 to 25K

0 to 30K

0 to 36K

0 to 40K

±2

±5

±10

±15

-15 to 30

-15 to 100

-15 to 300

5

10

15

30

50

100

300

500

1K

3K

AP5K

DP300

5K

Differential inH

2

O mbar

DP1

±1 ±2.5

DP2

±2 ±5

DP5

DP10

DP20

DP30

±5

±10

±20

±30

±10

±25

±50

±75

DP50

DP150

±50

±150

±160

±350

±300

350

±700

0.35

0.7

1

2

3.5

7

20

35

70

200

±0.16

±0.35

±0.7

±1

-1 to 2

-1 to 7

-1 to 20

bar

0 to 40

0 to 70

0 to 140

0 to 200

0 to 350

0 to 700

0 to 1K

0 to 1.4K

0 to 1.6K

0 to 2K

0 to 2.5K

0 to 2.8K

G

G

G

G

G

G, L

G, L

G, L

G, L

G, L

G, L

G

G

G

G

G

G, L

G, L

Media

G, L

G, L

G, L

G, L

G, L

G, L

G, L

G, L

G, L

G, L

G, L

G, L

G

G

G

G

G

G

G

G

G

ADT672 Series

Digital Pressure Calibrator

ADT681 Series

Digital Pressure Gauge

ADT680 Series

Digital Pressure Gauge

Look us up on www.additel.com or call today (1)714-998-6899

15

Additel 672

Digital Pressure Calibrators

Pressure ranges to 40,000 psi (2,800 bar)

HART Communication capability

Measure mA or V, and with 24V loop power

Easy-to-use, inexpensive pressure calibrator with uncertainty better than 0.02%FS

16

Gauge pressure Differential pressure

OVERVIEW

At first glance, the 672 series precision pressure calibrators look like an ordinary pressure gauge. But this series is much more than ordinary, and definitely more than just a pressure gauge—it’s a pressure calibrator! With advanced microprocessor technology and state-of-the-art silicon pressure sensors, the 672 series precision pressure calibrators provide a pressure calibration solution for gauges, transmitters, and switches over a wide pressure range. The 672 is the size of a pressure gauge but with the functionality of a calibrator: It measures pressure precisely with a builtin pressure sensor, as well as reads the current or mV produced by a transducer. It can even supply an excitation voltage to power sensors or transmitters during calibration. In order to reach 0.02%FS accuracy up to 10,000 psi

(700 bar) and 0.1%FS accuracy up to 40,000 psi (2,800 bar), every silicon pressure sensor has been specially aged, tested, and screened before assembly. The 672 series precision pressure calibrators are unmatched in performance and reliability.

FEATURES

Pressure ranges to 40,000 psi (2800 bar)

Measure mA with 0.01% RD + 1.5 μA accuracy

Measure V with 0.01% RD + 1.5 mV accuracy

Power transmitters during test using 24V loop supply

Pressure switch test

HART Communication capability

Advanced temperature compensation

Dual readout

Min/Max/Hold to capture changing measurements

Data logging

Large, easy to read display with 6-digit resolution

Backlit display

Rechargeable battery or AC adapter

NIST traceable calibration with data (Included)

SPECIFICATIONS

Accuracy

ADT672-02: 0.02% of full scale

ADT672-05: 0.05% of full scale

>20,000 (1,400 bar): 0.1% FS

Gauge Types

Gauge pressure

Compound Pressure

Absolute pressure

Differential pressure

Display

Description: Dual-line 6 full digit FSTN LCD with LED

Backlight

Display rate: 3.5 readings per second (Default setting)

Numeral display height: 16.5mm (0.65")

Pressure Units

Pa, kPa, MPa, psi, bar, mbar, inH

2

O@4°C, mmH

2

O@4°C, inHg@0°C, mmHg@0°C, kgf/cm

2

Environmental

Compensated Temperature: 14°F to 122°F (-10°C to

50°C)

Operating Temperature: 14°F to 122°F (-10°C to

50°C)

Storage Temperature: -4°F to 158°F (-20°C to 70°C)

Humidity: <95%

Look us up on www.additel.com or call today (1)714-998-6899

SPECIFICATIONS

Pressure Ranges

Gauge Pressure

[1]

P/N

V15

GP2

GP5

GP10

GP15

GP30

GP50

GP100

GP300

GP500

GP600

GP1K

GP2K

500

600

1,000

2,000

GP3K

GP5K

3,000

5,000

GP10K 10,000

GP15K 15,000

GP20K 20,000

GP25K 25,000

GP30K 30,000

GP36K 36,000

GP40K 40,000

5

10

15

30

50

100

300

Pressure Range

(psi)

-15

2

(bar)

-1.0

0.16

0.35

0.7

1.0

2.0

3.5

7.0

20

1,000

1,400

1,600

2,000

2,500

2,800

35

40

70

140

200

350

700

Media

[2]

G, L

G, L

G, L

G, L

G, L

G, L

G, L

G, L

G, L

G, L

G

G

G

G

G, L

[3]

G, L

[3]

G, L

G, L

G, L

G, L

G, L

G, L

[1] Sealed gauge pressure for above 1000 psi

[2] G=Gas, L=Liquid

[3] 0.02% FS for gas media only

Accuracy(%FS)

0.02 (0.05)

0.02 (0.05)

0.02 (0.05)

0.02 (0.05)

0.02 (0.05)

0.02 (0.05)

0.02 (0.05)

0.05 (0.1)

0.05 (0.1)

0.1

0.1

0.1

0.1

0.02 (0.05)

0.05

0.05

0.02 (0.05)

0.02 (0.05)

0.02 (0.05)

0.02 (0.05)

0.02 (0.05)

0.02 (0.05)

Burst

Pressure

1.5×

1.5×

1.5×

1.5×

1.1×

Compound Pressure

P/N

CP2

CP5

CP10

CP15

Pressure Range

(psi) (bar)

±2

±5

±10

±15

±0.16

±0.35

±0.7

±1

CP30 -15 to 30 -1 to 2

CP100 -15 to 100 -1 to 7

Media

G

G, L

CP300 -15 to 300 -1 to 20 G, L

G

G

G

G

Accuracy(%FS)

[1]

0.05

0.02 (0.05)

0.02 (0.05)

0.02 (0.05)

0.02 (0.05)

0.02 (0.05)

0.02 (0.05)

[1] FS specification applies to the span of the range

Burst

Pressure

Absolute Pressure

P/N

AP5

AP10

AP15

AP30

AP50

AP100

AP300

AP500

50

100

300

500

AP1K 1,000

AP3K 3,000

AP5K 5,000

Pressure Range

(psi)

5

(bar)

0.35

10

15

30

0.7

1.0

2.0

3.5

7.0

20

35

70

200

350

Media

G

G , L

G , L

G , L

G , L

G , L

G , L

G

G

G

G

0.1

0.1

0.1

0.1

0.1

0.05 (0.1)

0.05 (0.1)

0.05 (0.1)

0.05 (0.1)

0.05 (0.1)

0.05 (0.1)

Accuracy(%FS)

Burst

Pressure

Differential Pressure

P/N

DP1

DP2

DP5

DP10

DP20

DP30

DP50

DP150

DP300

Pressure Range

(inH

2

±1

O) (mbar)

±2.5

±2

±5

±5.0

±10

±10

±20

±30

±50

±150

±300

±25

±50

±75

±160

±350

±700

Media

G

G

G

G

G

G

G

G

G

Accuracy

(%FS)

0.05

[2]

100×

0.05

[2]

0.05

[2]

0.05

[2]

0.05

0.05

[1]

Burst

Pressure

100×

50×

20×

20×

20×

Static

Pressure

Range

±10 psi

±10 psi

±10 psi

±10 psi

±10 psi

0.05

0.02

0.02

±10 psi

±10 psi

50 psi

50 psi

[1] FS specification applies to the span of the range. Accuracy includes one year stability.

[2] 0.05%FS accuracy (incl 6 months stability). One year accuracy is

0.05%FS calibration accuracy combined with 0.05%FS one year stability.

Electrical Measurement Accuracy

Voltage DC

Current DC

DC 24V

Switch

[1]

Range Accuracy

±30.0000V

±30.0000mA

± (0.01%RD + 1.5 mV)

± (0.01%RD + 1.5 μA)

24V±0.5V max:50mA Protect at: 120mA

Status OPEN/CLOSED

[1] 1V~12V if switch has detective voltage

Look us up on www.additel.com or call today (1)714-998-6899

17

18

Additel 672

Digital Pressure Calibrators

SPECIFICATIONS

Pressure Connections

1/4NPT male, 1/2NPT male, 1/4BSP male, 1/2BSP male, M20X1.5 male (≤15,000 psi)

1/4HP female or 1/4HP male (>15,000 psi)

1/4HP female: Autoclave F-250-C, 9/16" - 18 UNF-2B

1/4HP male: Autoclave M-250-C, 9/16" - 18 UNF-2A

0.236 inch (Ø6mm) test hose (for differential pressure)

Other connections available per request

Electrical Connection

0.156 inch (Ø4mm) sockets

Over Pressure Warning: 120%

Data Logging

Storage capacity: 30 files, 40 records per file

Mode: manual and automatic

Hourly-record: record the data every hour

Interval-record: set by user

Power

Battery: Rechargeable Li-ion polymer battery

Li-Battery working time: 40 hours

Recharge time: 4 hours

External power: 110V/220V power adapter (DC10V)

Enclosure

Case material: Aluminum alloy

Wetted parts: 316L SS

Dimension: Ø120mm X 46mm depth X 184mm height

Weight: 0.7kg

European Compliance: CE marked

Communication

RS232 (DB9/F, environmentally sealed)

Baud rate: 1200,2400,4800,9600

Data length: 8 bits

Stop bit: 2 bits

Address: from 1 to 112

Warranty:1 year

ORDERING INFORMATION

Model Number

ADT672 02 GP300 PSI N

Model Range type:

PSI-range by psi

BAR-range by bar

H

2

O-range by inH

2

O

Accuracy:

02-0.02% of full scale

05-0.05% of full scale

10-0.1% of full scale

Pressure port type:

N-1/4NPT male

N2-1/2NPT male

B-1/4BSP male

B2-1/2BSP male

M-M20X1.5 male

AF-Autoclave F-250-C female

AM-Autoclave M-250-C male

Pressure range P/N:

See pressure range table

Look us up on www.additel.com or call today (1)714-998-6899

Accessories included

110V/220V external power adapter (DC 10V)

2 pieces 1.5-meter test leads

2 pieces 0.236 inch (Ø6 mm) test hose

(for differential pressure gauge only)

Additel/Land software

(free download at www.additel.com)

Manual

NIST traceable calibration certificate

Optional Accessories

Model number

9702

9816

9502

9506

Description

Spare rechargeable Li-ion polymer battery for 672

Spare 110V/220V external power adapter (DC 10V) for ADT22X and ADT672 calibrator

Additel/Log II real time data logging and graphical software for 681 and 672

Additel/PCal pressure calibration software

9050 USB to RS232 (DB9/M) Adapter

9900-672 Carrying Case for one 672 digital pressure gauge

9021 Spare 2 pieces test leads (1.5-meter) for 672

Application Note

Understanding Accuracy Specifications for Digital Pressure Sensors – Percentage of Full Scale Versus

Percentage of Reading

Specifications for digital pressure gauges can sometimes seem confusing or overwhelming, especially, if you are unfamiliar with the terminology. Some pressure sensors will specify accuracy as a percent of full scale (FS) while others provide the specification as a percent of reading. So why are there different ways of specifying the accuracy of pressure sensors and is percent of reading more accurate than percent of full scale or vise versa? This brief technical note will discuss the two differences and answer these questions.

Percentage of Reading Accuracy

psi

60

70

80

90

100

0

10

20

30

40

50

Figure 1 - Percent reading accuracy example

Full scale: 0 to 100 psi

Accuracy: 20 to 100% FS: 0.1% of reading

0 to 20% FS: 0.02% of FS

Accuracy

(psi)

0.06

0.07

0.08

0.09

0.10

0.02

0.02

0.02

0.03

0.04

0.05

0.02%FS

0.1% of

Reading

Accuracy as a percentage of reading is accomplished by multiplying the accuracy percentage by the pressure reading. Thus, the lower the pressure measurement, the better the accuracy. Instruments that have a percent reading specification are accompanied with a floor specification. The floor specification takes into account uncertainties such as resolution and measurement noise which may be negligible at higher pressures but are of much more significance at lower pressures.

For example, an accuracy specification may read 0.1% of reading for 20 to 100% of range and 0.02% of full scale below 20% of the range. The 0.02% of full scale specification is considered the floor specification. To understand the accuracy of the sensor, the user is then required to know where the floor spec is applicable and the full scale of the sensor.

This method of specification is often used because it aligns well with the typical performance of pressure gauges. Typically, the closer you measure to barometric pressure the better the performance of the gauge. Figures 1 and the graph below show an example specification for a 100 psi gauge and its accuracy in psi.

Look us up on www.additel.com or call today (1)714-998-6899

19

Percentage of Full Scale Accuracy

psi

60

70

80

90

100

0

10

20

30

40

50

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

Accuracy

(psi)

0.05%FS

Accuracy as a percentage of full scale is calculated by multiplying the accuracy percentage by the full scale pressure of the gauge. This is obviously a more simple method of specification and is most commonly used in industry because it is easy to calculate and interpret. Denoting the accuracy as percent full scale is a more conservative way of specifying the pressure sensor because typically the sensor doesn't perform the same over its full range. It usually will perform more accurately as you approach barometric pressure. This type of specification is most common for industrial gauges which make it easier to compare one gauge versus another. Figure 2 is an example specification for a 100 psi gauge and its accuracy in psi.

A Comparison of Percent of Full Scale and Percent of Reading Accuracies

psi

50

60

70

80

90

100

0

10

20

30

40

0.1% of

Reading

0.02

Accuracy

(psi)

0.05% of FS

0.05

0.02

0.02

0.03

0.04

0.05

0.06

0.07

0.08

0.09

0.10

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

So you may ask, "Which is more accurate?" The answer is that it depends on the pressure being measured. In the two examples given, the gauge specified at 0.1% of reading is more accurate as you measure lower pressures in its range. However, as you move above 50% of the range, the gauge specified at 0.05% of full scale becomes more accurate than the 0.1% of reading gauge. This can be seen clearly in the chart (left) and graph (below) where the two gauges are compared in terms of psi accuracy. To properly compare these, two gauges you should convert the accuracy to pressure units, such as psi or bar. Then they can be properly matched one against another in like units of measure.

In conclusion, one method of specification is not better than another, it is just different. Given this difference it becomes important to know how to interpret the different specifications types and be able to compare one versus another.

20

Look us up on www.additel.com or call today (1)714-998-6899

Additel 681

Digital Pressure Gauges

Pressure ranges to 40,000 psi (2,800 bar)

0.02%, 0.05%, 0.1%, 0.2% FS or 0.1%RD accuracy

% pressure indication with fan-shaped graph scale for visual reference

Now IP67 Rated!

Fully temperature compensated accuracy

Panel mount gauges are available

Intrinsically safe version (681IS)

Data logging option

IP67 rated (681IS)

Gauge pressure

OVERVIEW

Differential pressure

With advanced microprocessor technology and state-of-the-art silicon pressure sensors, the 681 series digital pressure gauges provide an accurate, reliable, and economic solution for a wide range of pressure applications.

They are loaded with functionality and remarkably easy to use. To reach the best performance, every silicon pressure sensor in our gauges is specially aged, tested and screened before assembly. At Additel, fully temperature compensated accuracy means every sensor is pressure tested at several environmental temperatures from

-10°C to 50°C. With this test data individual coefficients are generated and stored in the gauge characterizing its performance over the full temperature compensated range. And now the ADT681IS comes with an IP67 rating meaning it is dust resistant and water proof, submersible in 1 meter of water.

Designed to fit your need

Additel pressure gauges give you the widest variety of sensor choices on the market. Whether you require low inches of water measurement or very high pressure measurement, we have a gauge that will meet your need. We offer sensors which are ±1 inH

2

O (±2.5 mbar) to 40K psi (2,800 bar) and everything in between.

Do your applications require you to measure both positive and vacuum pressure? Our compound gauges do not compromise accuracy and provides you with the same high accuracy specification on both positive and vacuum pressures. We offer a wide variety up to 300 psi (20 bar). If you need a higher range, just contact us and we can likely customize one to meet your need. We also offer absolute pressure sensors to 5K psi (350 bar) and a full range of differential pressure sensors from ±1 inH

2

O (±2.5 mbar) to ±300 inH

2

O (±700 mbar). Are you looking for a pressure gauge to use in hazardous areas? Our ATEX-certified intrinsically safe models (681IS) are designed for pressure measurement in hazardous areas.

If you need to panel mount our sensors, we offer the option (see ordering information) for a back-mounted pressure port and gauge housing designed to fit in a panel. And most recently, we've added the option to do stand-alone data logging with the 681. Now you can record more than 21,000 records internal to the 681 series. Each record includes date, time, pressure and temperature readings. Download the logged data with our free Additel/Land software or you can purchase our Additel/Log II for real-time logging and data analysis. The 681 series digital pressure gauges are unmatched in performance and reliability. Best of all, they are very affordable.

FEATURES

Pressure ranges to 40,000 psi (2,800 bar)

0.02% full scale accuracy (681-02)

0.05% full scale accuracy (681-05)

0.1% full scale accuracy (681-10)

0.2% full scale accuracy (681-20)

0.1% reading scale accuracy (681-RD)

IP67 rated: Submersible in 1 meter of water(681IS)

Fully temperature compensated accuracy from

14°F to 122°F (-10°C to 50°C)

Up to eleven selectable pressure units

Large, easy to read display with 5-digit resolution

Backlit display

% pressure indication with fan-shaped graph scale for visual reference

Display flash warning when pressure over 120% of FS

Bottom mount or panel mount

ATEX certified intrinsically safe (Model 681IS)

NIST traceable calibration with data(included)

9V battery power or AC adapter (optional)

Data logging to 21,843 records (includes date, time, pressure and temperature)

Look us up on www.additel.com or call today (1)714-998-6899

21

22

SPECIFICATIONS

Model

ADT681: Regular gauge

ADT681IS: ATEX certified intrinsically safe

Accuracy

681(IS)-02 : 0.02% of full scale

681(IS)-05 : 0.05% of full scale

681(IS)-10 : 0.1% of full scale

681(IS)-20 : 0.2% of full scale

681(IS)-RD: 0% to 20% of Range: 0.02% of full scale

20% to 110% of Range: 0.1% of reading

Vacuum: 0.25% of full scale

[1][2]

[1] FS = -14.5 psi

[2] Applicable ADT681-RD-CPX

(For detailed accuracy, please see pressure range table)

Gauge Types

Gauge pressure

Compound pressure

Absolute pressure

Differential pressure

Fan-shaped Graph Scale

Similar to analog dials, including pressure swing,

% indication with fan-shaped graph scale for visual reference, low/high alarm.

Display

Description: 5 full digit FSTN LCD

Display rate: 3 readings per second (Default setting).

Adjustable from 10 readings per second to 1 reading every ten seconds

Numeral display height: 16.5mm (0.65")

Pressure Units

Pa, kPa, MPa, psi, bar, mbar, kgf/cm

2 mmH

2

, inH

O@4°C, inHg@0°C, mmHg@0°C

2

O@4°C

Environmental

Compensated Temperature: 14°F to 122°F (-10°C to

50°C)

Operating Temperature: 14°F to 122°F (-10°C to 50°C)

Storage Temperature: -4°F to 158°F (-20°C to 70°C)

Humidity: <95%

Pressure Port

1/4NPT male, 1/2NPT male, 1/4BSP male, 1/2BSP male, M20×1.5 male (≤15,000 psi)

1/4HP female or 1/4HP male(≥15,000 PSI)

*1/4HP female: Autoclave F-250-C, 9/16" - 18 UNF-2B

*1/4HP male: Autoclave M-250-C, 9/16" - 18 UNF-2A

0.236 inch (Ø6 mm) test hose (for differential pressure)

Other connections available per request

Power

Battery: One 9V alkaline battery (included)

Battery life: 300 hours (10 readings/s), 600 hours (3 reading/s), or 6000 hours (1 reading/10s)

Power auto-off: 60 minutes power auto-off. Auto-off may be disable

External power: 110/220V external power adapter

(optional)

Look us up on www.additel.com or call today (1)714-998-6899

Enclosure

Case material: Aluminum alloy

Wetted parts: 316L SS

Dimension: Ø110mm X 35mm depth X 176mm height

(panel mount gauge: Ø140mm X 86mm depth)

Weight: 0.6kg

Compliance

Protection Level: IP67(available for 681IS GP15-40K)

Vibration: 5g (20-2000 Hz)

Shock Resistance: 100g/11ms

Data Logging

Data storage: 21,843 records (each record includes date, time, pressure and temperature)

Rate: user-selectable from 1 to 99,999 second intervals

Intrinsic Safety and European Compliance

CE marked

ATEX certified intrinsically safe (ADT681IS)

II 1G EX ia IIC T4 Ga

Communication: RS232

*(Do not use the RS-232 connector in a hazardous atmosphere)

Warranty: 1 year

Pressure Ranges

Gauge Pressure

[1]

P/N

Pressure Range Media

[2]

(psi) (bar)

-15 -1.0

G

Accuracy

%FS %RD

0.02 (0.05, 0.1, 0.2) N/A V15

GP2

GP5

GP10

GP15

GP30

GP50

2

5

10

15

30

50

GP100 100

0.16

0.35

0.7

2.0

3.5

7.0

G

G

G

1.0

G, L

[3]

G, L

[3]

0.05 (0.1, 0.2)

0.05 (0.1, 0.2)

0.02 (0.05, 0.1, 0.2)

0.02 (0.05, 0.1, 0.2)

0.02 (0.05, 0.1, 0.2)

G, L 0.02 (0.05, 0.1, 0.2)

G, L 0.02 (0.05, 0.1, 0.2)

N/A

0.1

0.1

0.1

0.1

0.1

0.1

GP300 300

GP500 500

GP600 600

GP1K 1,000

20

35

40

70

G, L 0.02 (0.05, 0.1, 0.2)

G, L 0.02 (0.05, 0.1, 0.2)

G, L 0.02 (0.05, 0.1, 0.2)

G, L 0.02 (0.05, 0.1, 0.2)

GP2K 2,000

GP3K 3,000

140 G, L 0.02 (0.05, 0.1, 0.2)

200 G, L 0.02 (0.05, 0.1, 0.2)

GP5K 5,000 350 G, L 0.02 (0.05, 0.1, 0.2)

GP10K 10,000 700 G, L 0.02 (0.05, 0.1, 0.2)

GP15K 15,000 1,000 G, L 0.05 (0.1,0.2)

GP20K 20,000 1,400 G, L

GP25K 25,000 1,600 G, L

GP30K 30,000 2,000 G, L

GP36K 36,000 2,500 G, L

0.05 (0.1,0.2)

0.1 (0.2)

0.1 (0.2)

0.1 (0.2)

GP40K 40,000 2,800 G, L 0.1 (0.2)

[1] Sealed gauge pressure for above 1,000 psi

[2] G=Gas, L=Liquid

[3] 0.02% FS for gas media only

N/A

N/A

N/A

N/A

N/A

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

Burst

Pressure

1.5×

1.5×

1.5×

1.5×

1.1×

Additel 681 Digital Pressure Gauges

Absolute Pressure

P/N

AP5

AP10

AP15

AP30

AP50

AP100

AP300

AP500

AP1K 1,000

AP3K 3,000

AP5K 5,000

[1] G=Gas, L=Liquid

Pressure Range

(psi)

5

(bar)

0.35

10

15

30

50

100

300

500

7.0

20

35

0.7

1.0

2.0

3.5

70

200

350

Media

[1]

G

G

G, L

G, L

G, L

G

G

G

G, L

G, L

G, L

Accuracy(%FS)

0.1 (0.2)

0.1 (0.2)

0.1 (0.2)

0.1 (0.2)

0.1 (0.2)

0.05 (0.1, 0.2)

0.05 (0.1, 0.2)

0.05 (0.1, 0.2)

0.05 (0.1, 0.2)

0.05 (0.1, 0.2)

0.05 (0.1, 0.2)

Burst

Pressure

ORDERING INFORMATION

Model Number

ADT681 02 GP300 PSI N PB DL

DP1

DP2

DP5

DP10

DP20

DP30

DP50

DP150

DP300

Differential Pressure

P/N

Pressure Range

±2

Media

(inH

2

O) (mbar)

±1 ±2.5

G

±5.0 G

±5 ±10

±10 ±25

±20 ±50

G

G

G

±30

±50

±150

±300

±75

±160

±350

±700

G

G

G

G

Accuracy

(%FS)

[1]

0.05

[2]

100×

0.05

[2]

0.05

[2]

100×

50×

0.05

[2]

0.05

20×

20×

0.05

0.05

20×

0.02 (0.05)

0.02 (0.05)

Burst

Pressure

Static

Pressure

Range

±10 psi

±10 psi

±10 psi

±10 psi

±10 psi

±10 psi

±10 psi

50 psi

50 psi

[1] FS specification applies to the span of the range. Accuracy includes one year stability.

[2] 0.05%FS accuracy (incl 6 months stability). One year accuracy is

0.05%FS calibration accuracy combined with 0.05%FS one year stability.

Compound Pressure [1]

P/N

CP2

CP5

CP10

CP15

CP30

Pressure Range

(psi)

±2

(bar)

±0.16

Media

[2]

G

±5 ±0.35

G

Accuracy

%FS

[3]

%RD

0.05 (0.1,0.2) N/A

0.02 (0.05,0.1,0.2) 0.1

Burst

Pressure

±10

±15

±0.7

±1

-15 to 30 -1 to 2

G

G

G

0.02 (0.05,0.1,0.2)

0.02 (0.05,0.1,0.2)

0.02 (0.05,0.1,0.2)

0.1

0.1

0.1

CP100 -15 to 100 -1 to 7 G, L 0.02 (0.05,0.1,0.2) 0.1

CP300 -15 to 300

-1 to

20

G, L 0.02 (0.05,0.1,0.2)

[1] Sealed gauge pressure for above 1,000 psi.

[2] G=Gas, L=Liquid

[3] FS specification applies to the span of the range.

0.1

Model:

ADT681

ADT681IS

Accuracy:

02-0.02% of full scale

05-0.05% of full scale

10-0.1% of full scale

20-0.2% of full scale

RD-0.1% of reading

Pressure range P/N:

See pressure range table

Range type:

PSI-range by psi

BAR-range by bar

H

2

O-range by inH

2

O

Pressure port type:

N- 1/4NPT male

N2- 1/2NPT male

B-1/4BSP male

B2-1/2BSP male

M-M20X1.5 male

AF-Autoclave F-250-C female

AM-Autoclave M-250-C male

PB: Panel mount with back pressure port

DL: Data logging

Accessories included

Rubber boot (Except panel mount)

9V alkaline battery (1 pc)

Manual

NIST traceable calibration certificate

Optional Accessories

Model number

9812

9502

9506

Description

110V/220V external power adapter (DC 9V) for 681 digital pressure gauge.

Additel/Log II real time data logging and graphical software for 681 and 672.

Additel/PCal pressure calibration software

9050 USB to RS232 (DB9/M) Adapter

9900-681

9251

Carrying Case for one 681 digital pressure gauge

Rubber boot for ADT681

Note: For oil-free applications contact Additel.

Look us up on www.additel.com or call today (1)714-998-6899

23

Additel 680 Series

Digital Pressure Gauges

Pressure ranges to 40,000 psi (2,800 bar)

0.05%, 0.1% or 0.25%FS accuracy

Fully temperature compensated accuracy

IP67

Data logging and wireless (680W)

24

OVERVIEW

680 with data logging and wireless (optional)

We designed the 680 series digital pressure gauges with two main objectives in mind. First, to provide an affordable digital gauge to replace mechanical gauges. If you’re looking to move from dial gauges to a digital gauge, you’ll find the 680 standard version gauge to be of high quality and suited for your need in terms of price and performance. With advanced microprocessor technology and state-of-the-art silicon pressure sensors, the 680 series digital pressure gauges provide an accurate, reliable, and economic solution for a wide range of pressure applications. They are loaded with functionality and remarkably easy to use. To reach the best performance, every silicon pressure sensor is specially aged, tested and screened before assembly.

The second objective was to provide a high-precision pressure gauge capable of wireless communication and data logging. Our 680W series provides just this along with several accuracy and pressure range options to meet your need. This wireless unit is compatible with the Additel/Land Wireless software, which is available for a free download from our website. Data can be recorded standalone with the 680W and then downloaded wirelessly to Additel/Land

Wireless. For more advanced logging and data analysis, Additel/Log II Wireless is specially designed to communicate with the 680W. Each unit can store up to 140,000 readings which consist of date, time, pressure, and internal temperature. The 680 series digital pressure gauges are unmatched in performance and reliability. Best of all they are very affordable.

FEATURES

Pressure ranges to 40,000 psi (2,800 bar)

0.05%, 0.1% or 0.25% full scale accuracy

Fully temperature compensated accuracy from

14°F to 122°F (-10°C to 50°C)

Up to 13 selectable pressure units, 6 customized definition engineering units

Large, easy to read display with 5-digit resolution

Backlit display

Icon-based menu

Display flash warning when pressure exceeds

120% of FS

Stainless wetted surface construction

IP67 (submersible in 1 meter of water)

Drop-tested from 1 meter

2 AA alkaline batteries

CE R&TTE, FCC ID, IC ID Certificates

NIST traceable calibration with data(included)

SPECIFICATIONS

Models

ADT680: Regular version

ADT680W: Data logging and wireless version

Pressure Type: Gauge and Compound

Look us up on www.additel.com or call today (1)714-998-6899

Performance

Accuracy: 0.05%, 0.1% or 0.25%FS

Update Rate: 10 times/Sec ,3 times /Sec (default),

1 time /Sec ,1 time/15 Seconds

Operating Temperature: 14°F to 122°F (-10°C to 50°C)

Compensated Temperature: 14°F to 122°F (-10°C to

50°C), accuracy guaranteed

Storage Temperature: -4°F to 158°F (-20°C to 70°C)

Overload Pressure: 1.2X

Power Supply

Battery: 2 x AA alkaline (LR6) batteries

*Recommend: Duracell MX1500, EnergizerE91,

Panasonic LR6, or Duracell 15AU

Battery Life:

10 rdg/sec: 1500 hrs; 3 rdg/sec: 3000 hrs

1 rdg/sec: 6000 hrs; 1 rdg/15 sec: 12000 hrs.

Rated Power: 3.0VDC Imax=30mA Pmax=90mW

Material

Wetted Surface: All wetted surfaces are 316L Stainless

Steel with welded design for gauges ≤10,000 psi (no

O-ring, thread tape, epoxy, or sealant on any part of the sensor assembly), and copper O-ring design for gauges > 10,000 psi.

Case: PC+ABS

Protective Cover: Silicone Rubber

SPECIFICATIONS

P/N

V15

GP15

GP30

GP100

GP300

GP500

GP1K

GP3K

GP5K

GP10K

GP15K

GP20K

GP25K

GP30K

GP36K

GP40K

Display

LCD Specification: FSTN-LCD,Visual scope 36x61mm;

Full 5 digits,15.2mm High; 7 segment analog bar graph scaled from 0-100% of FS

Backlight: White

Wireless Communication (ADT680W only)

Wireless Frequency: 2.4G ISM Bands, 20 meter range

Number of wireless Channels : Chanel 1-15

Software: Wireless network demo software included

Read upto 20 gauges.

Data Logging (ADT680W only)

Storage Capacity: 140,000 readings(time, pressure, and temperature)

Storage Interval: Adjustable from 1-9999 Sec

Single-button-press data logging enabled

Compliances

Certificates:CE R&TTE, FCC ID, IC ID

Protection Level: IP67

Vibration: 5g(20-2000Hz)

Shock resistance: 100g/11ms

Others

Dimensions: 100mm x 40mm, total height:157mm

Weight: 500g

Fitting: 1/4NPT male, 1/2NPT male, 1/4BSP male,

1/2BSP male, M20×1.5 male (≤15,000 PSI)

1/4HP female or 1/4HP male(≥15,000 PSI)

*1/4HP female: Autoclave F-250-C, 9/16" - 18 UNF-2B

*1/4HP male: Autoclave M-250-C, 9/16" - 18 UNF-2A

Other connections available per request

Gauge Pressure

500

1,000

3,000

5,000

10,000

15,000

20,000

25,000

30,000

36,000

40,000

Pressure Range

(psi)

[1]

(bar)

-15

15

-1.0

1.0

30

100

300

2.0

7.0

20

1,400

1,600

2,000

2,500

2,800

35

70

200

350

700

1,000

Accuracy(FS%) Media

[3]

Burst

Pressure

0.05 (0.1, 0.25)

0.05 (0.1, 0.25)

0.05 (0.1, 0.25)

0.05 (0.1, 0.25)

0.05 (0.1, 0.25)

0.05 (0.1, 0.25)

0.05 (0.1, 0.25)

0.05 (0.1, 0.25)

0.05 (0.1, 0.25)

0.05 (0.1, 0.25)

0.05 (0.1, 0.25)

0.05 (0.1, 0.25)

0.1 (0.25)

0.1 (0.25)

0.1 (0.25)

0.1 (0.25)

G,L

G,L

G,L

G,L

G,L

G,L

G,L

G,L

G,L

G,L

G,L

G

G,L

G,L

G,L

G,L

1.5×

1.5×

1.5×

1.5×

1.1×

Compound Pressure

[1]

P/N

Pressure Range

(psi) (bar)

Accuracy(FS%)

[2]

CP15 ±15 ±1 0.05(0.1, 0.25)

CP30 -15 to 30 -1 to 2 0.05(0.1, 0.25)

[1] Sealed gauge pressure for above 1,000 psi.

[2] FS specification applies to the span of the range.

[3] G=Gas, L=Liquid

Media

[3]

Burst

Pressure

G,L

G,L

Auto off:

Disabled,15, 30, 45, 60, 90, or 120 Minutes.

Filtering: Averaging (3 to 10 samples) or low-pass firstorder filter.

Engineering units: Pa, kPa, MPa, bar, mba, psi, kgf/ cm

2

, mmH

2

O, mmHg, inH extend units: inH

2

2

O, inHg, ozf/in, %, °C, °F.

O(20°C), inH O(20°C), mmH

2

O(15°C), ftH

2

2

O(60°F), mmH

O(60°F), or ftH

2

O(4°C)

2

Backlight Duration:

Not auto off,15,30,45,60 seconds optional.

Max/Min data capture: Saves Max and Min data during pressure measurement.

Key Lockout: When the gauge is in auto-storing mode, the front panel buttons will be automatically locked.

Overpressure Alarm: Display will flash over 120%FS

Battery voltage Indicator: Displays the battery life remaining. When the battery voltage is too low, the gauge will power-off automatically.

Overpressure Record:

Gauge will record max pressure data when the gauge is over pressured by 120% of FS.

Leakage test:

In leak test mode, the gauge will record beginning pressure, ending pressure, and show the difference ΔP.

Factory Reset:

Resets all settings back to factory default, except the calibration parameters.

Warranty: 1 year

ORDERING INFORMATION

Model Number

ADT680

Model:

ADT680

ADT680W

25 GP300 PSI

Range type:

PSI-range by psi

BAR-range by bar

N

Accuracy:

05-0.05% of full scale

10-0.1% of full scale

25-0.25% of full scale

Pressure range P/N:

See pressure range table

Pressure port type:

N-1/4NPT male

N2-1/2NPT male

B-1/4BSP male

B2-1/2BSP male

M-M20X1.5 male

AF-Autoclave F-250-C female

AM-Autoclave M-250-C male

Accessories included

AA battery (2 pcs); Manual; NIST traceable calibration certificate;

Rubber boot for Additel 680 gauge;

Additel/Land Wireless software for 680W (free download at www.

additel.com)

Optional Accessories

Model number Description

9503

9030

Additel/Log II Wireless real time data logging and graphical software for 680W

Spare wireless master device (USB dongle) for

ADT680W gauge.

Note: For oil-free applications contact Additel.

Look us up on www.additel.com or call today (1)714-998-6899

25

Application Note

Why Temperature Compensation Really Matters for Pressure Measurement

Have you ever wondered how much impact environmental temperature has on your pressure sensors? Nearly every pressure sensor has some sort of environmental temperature specification on its data sheet. This technical note explains the environmental temperature effects on pressure sensors, quantifying the impact, and ways to minimize the impact.

Why pressure sensors are impacted by environmental temperature changes

Much like anything else in the physical measurement world, pressure sensors are subject to changes in environmental conditions. Temperature effects tend to have the largest impact on pressure measurement accuracy. Temperature effects directly influence the pressure sensor and the circuitry used to measure the sensor. Digital pressure sensors use electronic circuits which provide an analog output proportional to the inlet pressure. There are three factors of a sensor's circuitry that are affected by environmental temperature changes: zero pressure output voltage, pressure sensitivity span and bridge resistance. Temperature-compensated sensors employee some techniques to correct for and minimize the impact of temperature changes on these factors.

To understand the environmental temperature effect on your sensor, it is helpful to first understand some common terms you may see on a pressure sensor specification sheet.

Operating Temperature Range: This is the temperature range over which the sensor can be used without causing damage.

Temperature Compensated Accuracy Range: This refers to the environmental temperature range over which the accuracy of the sensor is applicable.

Temperature Coefficient: An additional error that needs to be considered when used outside of the temperature compensated accuracy range. Many sensors are only tested and calibrated at laboratory temperatures. In this case, the temperature coefficient will need to be considered in the measurement accuracy when using the sensor outside of laboratory temperatures.

Quantifying the environmental temperature effect

So how much will the ambient temperature impact your measurement accuracy? Well, this will depend on the temperature compensated accuracy range and the temperature coefficient. To demonstrate this, let's consider three different gauges. As you can see from the specifications below (figure 1), they all have the same accuracy specification of 0.05% FS. However, as you consider the temperature compensated accuracy range and the temperature coefficient you'll see a fairly large variation between the three gauges.

Figure 1 Manufacturer 1 Manufacturer 2 Manufacturer 3

Accuracy

0.05% FS

Temperature Compensated Accuracy

Range

Temperature Coefficient

N/A

Add 0.003% FS/°C from 23°C

0.05% FS

15°C to 35°C

Add 0.003% FS/°C: -10°C to

15°C, 35°C to 50°C

0.05% FS

-10°C to 50°C

N/A

The graph below shows the total specified accuracy when considering the temperature effects on the pressure gauges. As you can see in one case here, the lack of temperature compensation and inclusion of the temperature coefficient specification more than triple the 0.05% FS accuracy specification

26

Look us up on www.additel.com or call today (1)714-998-6899

Temperature compensation test results

To further show temperature compensation has real effect, we placed a non-temperature compensated pressure gauge in a temperature chamber and pressure tested it from 0 to 580 psi (0 to 40 bar) and over the environmental temperature range of 0°C to 40°C. We then performed the same test on a temperature compensated gauge. As you may expect—the higher the pressure, the larger the impact from the environmental temperature. Below is a chart comparing the non-temperature compensated gauge with the temperature compensated gauge.

Minimizing environmental temperature error

The temperature effect on a pressure sensor will be negligible when used at the same laboratory temperature in which it was calibrated. This, however, is often not practical for your measurements.

With sensor technology advances, we have found a variety of ways to minimize the temperature effect on pressure sensors and with confidence define a large temperature compensated accuracy range. First, regularly zero your digital pressure gauges. By zeroing the pressure gauge, you are aligning the zero pressure output voltage to the current environmental conditions. You should only zero the pressure gauge when you do not have any inlet pressure on the gauge.

Because each sensor is unique and performs differently due to environmental temperature changes, at Additel, we pressure test every sensor in a thermal chamber at different temperatures so we understand its pressure performance relative to environmental changes. Each sensor contains a temperature-compensated circuit which we load coefficients representing the temperature testing of the gauge. This allows for you to confidently use our sensors over the range -10°C to 50°C without having to add a temperature coefficient error to the accuracy.

Look us up on www.additel.com or call today (1)714-998-6899

27

Multifunction Process Calibrators

Selection Guide

Models

Additel 209 Loop

Calibrator

Additel 210

Loop Calibrator

Additel 220

Multifunction Loop

Calibrator

Measure

Voltage(mV)

Voltage(V)

Current (mA)

Resistance(ohm)

Frequency(Hz)

Pulse

Limit Switch

Pressure

Source / Simulate

Voltage(mV)

Voltage(V)

Current (mA)

Resistance(ohm)

Frequency(Hz)

Pulse

DC 24 V

Record

Scaling

Min/Max/Avg/Tare

Hold

As found/ As left

On-demand logging

Upload data to PC

Features

24V loop supply

Ramp/ Step

Simulate Transmitter

RTD

Thermocouple

HART communication

Documenting

Warranty

NIST traceable calibration

See Page

0 to 30 V

0 to 24 mA

0 to 24 mA

3 years

P27

0 to 30 V

0 to 24 mA

0 to 24 mA

3 years

P27

±300 mV

±60 V

±30 mA

0 to 2,000 Ω

3 to 24V

-10 to 200 mV

0 to 12 V

0 to 22 mA

[4]

3 years

P29

11 types

[2]

13 types

[3]

3 years

P31

Additel 221A

Multifunction

Temperature

Calibrator

Additel 222A

Multifunction Process

Calibrator

Additel 223A

Documenting Process

Calibrator

±75 mV

±30 V

±30 mA

0 to 4,000 Ω

1 to 50,000 Hz

0 to 999,999

3 to 24V

-10 to 75 mV

0 to 12 V

0 to 22 mA

1 to 4,000 Ω

0 to 50,000 Hz

0 to 999,999

±75 mV

±30 V

±30 mA

0 to 4,000 Ω

1 to 50,000 Hz

0 to 999,999

3 to 24V

[1]

-10 to 75 mV

0 to 12 V

0 to 22 mA

1 to 4,000 Ω

0 to 50,000 Hz

0 to 999,999

±75 mV

±30 V

±30 mA

0 to 4,000 Ω

1 to 50,000 Hz

0 to 999,999

3 to 24V

[1]

-10 to 75 mV

0 to 12 V

0 to 22 mA

1 to 4,000 Ω

0 to 50,000 Hz

0 to 999,999

11 types

[2]

13 types

[3]

3 years

P31

11 types

[2]

13 types

[3]

3 years

P31

[1] Additel 160A External Pressure Module required

[2] RTD Includes Pt10(385), Pt100(385), Pt100(3916), Pt100(3926), Pt500(385), Pt1000(385),

Cu10(427), Cu50(428), Cu100(428), Ni100(617), Ni120(672),Ni1000 and customized

[3] Thermocouple Includes S, R, B, K, N, E, J, T, C, D, G, L, U

[4] Built-in 250Ω resistor for HART communications.

28

Look us up on www.additel.com or call today (1)714-998-6899

Additel 209 and 210 Series Loop Calibrator

Accuracy to 0.01% of reading

Small and rugged handheld design

Measure, source, or simulate loop current

Measure DC volts

Simultaneously mA and % span display

Switch functionality

Selectable ramp and step functions

Easy to read display and user interface

HART 250Ω resistor in series with 24V loop

OVERVIEW

The new Additel 209 and 210 loop calibrator series combine ease of use and functionality, making them the ideal tools to troubleshoot your process loop.

The ADT209 has an accuracy of 0.03% of reading whereas the ADT210 holds an accuracy of 0.01% of reading. If you want to source, simulate or simply measure, the Additel Loop calibrator series will fit your need. The

ADT209 and ADT210 allow for measurement of current, voltage and a switch.

You can also simulate or source mA or a process transmitter. With a push of a button, you can switch to zero and span values, auto ramp, and auto step throughout the range. Each loop calibrator has a large, easy to read screen which simultaneously displays the measurement with the % of span.

ELECTRICAL MEASURE SPECIFICATIONS

Range Resolution ADT209 Accuracy

Voltage DC

1

0 to 30 V 1 mV 0.03%RD + 2mV

Current DC

2

0 to 24 mA 1 μA 0.03%RD + 2μA

Switch test

Input resistance more than 500 MΩ

Trigger level: low level <0.3V; high level: >2V

[1] 1MΩ input resistance

[2] Loop transmitter current measure: 700Ω maximum

ADT210 Accuracy

0.01%RD + 2mV

0.01%RD + 2μA

ELECTRICAL SOURCE SPECIFICATIONS

Range Resolution ADT209 Accuracy ADT210 Accuracy

Current DC

0 to 24 mA 1 μA

Source mode

700Ω/20 mA maximum

Sink mode

0.03%RD + 2μA 0.01%RD + 2μA

External loop voltage nominal 24V, maximum 30V, minimum 12V

Look us up on www.additel.com or call today (1)714-998-6899

29

GENERAL SPECIFICATIONS

Voltage limit

Measurement Functions

Display

Loop power

Over-voltage protection

Overload current protection

Storage temperature

Working Environment

Working Altitude

Vibration/shock

Power

Battery life (typical)

Size (LxWxH)

Weight

Calibration Certification

Compliance Certification

Warranty

30V between terminals or between terminals and ground

Auto step, auto ramp, span step

VA LCD display. 2.04 x 2.04 in (52 x 52 mm)

24V

30V DC (240V AC)

33 mA DC

-20°C to 70°C

-10 to 50°C, 95%RH

<3,000 m

Random 2G 5 to 500Hz

1 meter drop

One 9V alkaline battery (ANSI/NEDA 1604A or IEC)

DC9V optional adapter available

Output mode: 18 hours (12 mA/500Ω)

Measure mode: 50 hours

163 x 83 x 41 mm

350 g

NIST-traceable certificate of calibration with data

ADT209: CSA, CE, DNV

ADT210: CSA, CE, DNV

3 years

ORDERING INFORMATION

Model Number

ADT209

ADT210

Accessories included

Test lead set

Alligator clips

User manual

9V Alkaline battery

1 set

2 pcs

1 pc

1 pc

Optional Accessories

9812 110V/220V external power adapter (DC 9V)

30

Look us up on www.additel.com or call today (1)714-998-6899

Additel 220

Multifunction Loop Calibrator

Measure and source loop current, mV, and V

Measure and source simultaneously

Loop Continuity Test capability

24V loop supply with simultaneous current measurement

3 year warranty

OVERVIEW

The 220 is a highly integrated loop calibrator featuring several patented technologies. The calibrator is an ultra-compact, rugged, and best of all, easy to use hand-held device that will source, simulate and measure loop current, mV/V, Loop

Continuity Test, and also perform switch testing. Its smart phone-like menu and interface makes it simple and easy to use. The 220 is ideal for calibrating, maintaining, and troubleshooting various loop devices in the field.

FEATURES

Measuring and sourcing loop current, mV and V

Measures loop current up to 30mA with 0.1μA resolution

Measures voltage signals up to 60 V, and mV signals up to 300 mV

Sources/sink loop current, mV and V

24V loop power supply with simultaneous current measurement

Simultaneous dual reading capability

Capture switch

Data statistics and analysis

Display max, min, peak-to-peak, average, and percentage simultaneously

Convert data to a real physical value through re-scaling function

On-demand logging

High-capacity storage with up to twenty thousand records

On-line view, index, analyze, auto-curve, and list the data

Various sources and converting mode

Support linear, flow, valve, and 25% stepping source

Auto-source of ramping and stepping

Gauge span examination

"As Cal" on-site calibration tools

Four on-site calibration tools preset: loop indicator, sensor/transmitter, signal isolator/converter, and limit alarm/switch

Support 2W transmitter connection

Multi lingual interface

English,Simplified Chinese

Convenient tools

Calculator, thermocouple converter, HOLD screen lock

Display rate

4 readings/second

Easy to use

Smartphone-like menu and interface make the operation simpler and easier

Ultra-compact, size 3.9" x 7.6" x 2.0" (100mm x

192mm x 52mm), and weight 1.6 lb (0.7 kg)

One hand operation

Snapshot

Save and manage up to 100 snapshots

Display

3.5 inch TFT color screen

4, 5, or 6 digits adjustable display

Rugged

Rugged design for harsh environments.

Passed a 1-meter drop test

Three years warranty for the 220, and one year for the battery pack

Misuse protection and Electrical isolation

Up to 30V voltage on any two sockets and up to

1A current on current sockets will not damage the calibrator. The calibrator will return to normal condition as soon as the voltage or current is removed.

Measuring, sourcing and loop power circuits are electrically isolated each other.

Rechargeable battery

Rechargeable Li-ion battery for 15 hours uninterrupted use.

Battery life will be reduced when 24V is applied.

The rechargeable battery is replaceable.

NIST Traceable Calibration with data

Firmware upgrade

Support firmware upgrade when available

Warranty: 3 years

Look us up on www.additel.com or call today (1)714-998-6899

31

Additel 220

Multifunction Loop Calibrator

APPLICATIONS

The 220 loop calibrator is a process tool for measuring, sourcing and simulating mA, mV and V, captures switch values and provides 24V loop power. It is a high performance solution for calibration, repair and maintenance of various loops devices, Loop Continuity Test, and switch capture.

32

SPECIFICATIONS

Electrical Specifications

Measurement Accuracy

Range

-300.000 to 300.000 mV

Resolution

1μV

Voltage DC

-60.0000 to 60.0000 V 0.1mV

Current DC

-30.0000 to 30.0000 mA 0.1μA

Loop

Continuity

0 to 2000.0 ohm 0.1Ω

Accuracy

0.01%RD+15μV

0.01%RD+3mV

0.01%RD+1.5μA

0.02%RD+0.2Ω

Source Accuracy

-10.00 to 200.00 mV

Voltage DC

Current DC

0 to 12.000 V

0 to 22.000 mA

DC24V

N/A

General Specifications

Environmental Specifications

Operating

Temperature

Storage Temperature

Humidity

0.01mV

1mV

1μA

N/A

-10°C to 50°C

-20°C to 60°C

<90%, non-condensing

0.02%RD+10.5μV

0.02%RD+0.6mV

0.02%RD+1.1μA

0.5V

Safety Specifications

European

Compliance

CE Mark

Mechanical Specifications

Display

Electrical Connection

RS232 Interface

Size

Weight

Power Supply

Battery

Battery Life

Battery Charge

3.5 inch TFT color screen

Ø4mm sockets and flat mini-jack thermocouple socket

Standard RS232-DB9 socket

3.9" x 7.6" x 2.0" (100mm x 192mm x 52mm)

1.6 lb (0.7 kg)

Polymer Li-ion rechargeable battery,or 10V DC adaptor

Rechargeable Li-ion battery (included)

15 hours uninterrupted use

Battery life will be reduced when 24V is applied

110V/220V external power adapter (included)

Look us up on www.additel.com or call today (1)714-998-6899

ORDERING INFORMATION

Model Number

ADT220

Accessories (included)

110V/220V external power adapter

Chargeable Li-ion battery

Test leads

Short circuit cable

Manual

NIST traceable calibration certificate

1 pc

1 pc

2 sets(4 pcs)

1 sets(2 pcs)

1 pc

1 pc

* Additel/Land software could be downloaded for free at www.additel.com

Optional Accessories

Model number

9050

9712

9816

9906

Description

USB to RS232 (DB-9 Male) Adapter

Spare chargeable Li-ion battery for multifunction calibrator

110V/220V external power adapter

Carrying case for multifunction calibrator

Additel 221A, 222A & 223A

Multifiction Documenting Process

Calibrators

Sourcing, simulating and measuring pressure, temperature and electrical signals

Smartphone-like menu and interface make the operation simple

HART Communication capability (223A)

The internal cold junction compensation sensor can be re-calibrated at ice point by user

Ultra-compact, 3.9" x 7.6" x 2.0", and 1.6 lb (0.7 kg)

OVERVIEW

This series of highly integrated multifunction calibrators feature several patented technologies. These are an ultracompact, rugged, and easy to use hand-held device for sourcing, simulating and measuring pressure, temperature, and electrical signals. Their smartphone-like menu and interface make the operation simple. Automation and documentation capabilities make the these calibrators a turnkey solution.

Additel 221A

The Additel 221A is very unique to the multifunction temperature calibrator market. Not only does it provide you with the ability to source, simulate and measure temperature and electrical functions but it also incorporates full documenting capability and many other solutions other products do not provide. As a standalone device, you can create tasks, run tests and store the results. With the use of Additel/Land Software or Additel/Cal software, all saved tasks and data can be downloaded and managed. With it's unique internal could junction compensation sensor, cold junction compensation is very simple and easy.

Additel 222A

The Additel 222A Multifunction Process Calibrator takes all the functionality of the 221A and adds the ability to measure and source pressure using the ADT160A Intelligent Pressure Modules. With calibration characteristics programmed directly into the ADT160A pressure modules you can simply connect it to the 222A and it will automatically recognize and display the module as the source or measure pressure. For ultimate convenience, one 222A allows for modules to be

"hot swapped" with a simple connection at the top of the module.

Additel 223A

The 223A has all the capability of the 221A and 222A and HART Communication in one small, easy-to-use package.

The 223A has a full HART library that allows for the reading of HART-smart devices and also the capability to write to devices. Combined with full task automation and documentation, the 223A is an ideal tool to accomplish many of your important tasks.

FEATURES

Sourcing, simulating and measuring temperature and electrical signals

Sources and measures mV, mA, ohms, RTDs, thermocouples, frequency, and pulses

Simulates and measures 13 thermocouples and 11

RTDs to calibrate transmitters

Measures and sources pressure using Additel 160A series Intelligent Digital Pressure Modules from -15 psi to 10,000 psi (-1 bar to 700 bar)

24V loop power supply

Simultaneous dual reading capability

Automatic switch test

Supports square root transmitter

Pulse frequency output for the calibration of flow totalizer

Easy to use

Smartphone-like menu and interface make the operation simpler and easier

Ultra-compact, size 3.9" x 7.6" x 2.0" (100mm x 192mm x 52mm), and weight 1.6 lb (0.7 kg)

One hand operation

Calibrated cold junction compensation (Patented)

Cold junction equivalent block in the calibrator

A calibrated PRT element with flexible leads is installed in the equivalent block for thermocouple cold junction compensation

This PRT element can be pulled out from the calibrator and re-calibrated and corrected at ice point by users

Documenting and automated procedure capability

Manage the information of the device under test.

Set up automated calibration procedures, and 223A performs the test, calculates the errors, displays and/ or stores the results in the memory, and highlights the out-of-tolerance points.

As-found and As-left functions allow recording and documenting results for quality control.

Download tasks and upload the results.

Snapshots allow you to capture and save work.

NIST Traceble Cable with data

Look us up on www.additel.com or call today (1)714-998-6899

33

34

Built-in temperature readout

CVD coefficients of a calibrated PRT can be input into the calibrator for accurate temperature measurement.

Multi lingual interface

English, German, French, Italian, Spanish, Portuguese,

Simplified Chinese

(Traditional Chinese, Japanese and Russian are available per request)

Build-in unit conversion tool

Build-in converters for pressure units, temperature units, temperature vs. resistance (RTDs), and temperature vs millivolt (thermocouples)

Warranty:3 years

SPECIFICATIONS

Electrical Specifications

Measurement Accuracy

Range Resolution Accuracy

Voltage DC

±75.0000 mV

±30.0000 V

Current DC

± 30.0000 mA

Two-wire

0 to 400.000 Ω

Three-wire 0 to 400.000 Ω

0.1μV

0.1 mV

0.1μA

1mΩ

Four-wire

0 to 400.000 Ω

Two-wire

0 to 4000.00 Ω

1mΩ

1mΩ

Resistance

Three-wire 0 to 4000.00 Ω

Four-wire

Frequency

0 to 4000.00 Ω

10mΩ

10mΩ

10mΩ

1 to 50000.0 Hz 0.1Hz

Pulse

0 to 999999 1

Limit Switch

0.01%RD + 3.75 μV

0.01%RD + 1.5 mV

0.01%RD + 1.5 μA

0.02%RD + 0.02 Ω

0.02%RD + 0.02 Ω

0.01%RD + 0.02 Ω

0.02%RD + 0.2 Ω

0.02%RD + 0.2 Ω

0.01%RD + 0.2 Ω

0.005%RD + 1 Hz

N/A

For the contact with potential, the voltage within the range 3V to 24V.

Source Accuracy

Voltage DC

Current DC

Resistance

Frequency

Pulse

DC24V

-10.000 to 75.000mV

0 to 12.0000 V

0 to 22.000 mA

1 to 400.00 Ω

1 to 4000.0 Ω

0 to 50000.0 Hz

0 to 999999

N/A

1μV

0.1mV

1μA

10mΩ

100mΩ

0.1Hz

1

N/A

0.02%RD + 4.25 μV

0.02%RD + 0.6 mV

0.02%RD + 1.1 μA

0.02%RD + 0.02 Ω

0.03%RD + 0.4 Ω

0.005%RD + 1 Hz

N/A

0.5V

General Specifications

Environmental Specifications

Operating Temperature

Storage Temperature

Humidity

-10°C to 50°C

-20°C to 60°C

<90%, non-condensing

Safety Specifications

European Compliance

CE Mark

Mechanical Specifications

Display

3.5 inch TFT color screen

Electrical Connection Ø4mm sockets and flat mini-jack thermocouple socket

RS232 Interface

Size

Standard RS232-DB9 socket

3.9" x 7.6" x 2.0" (100mm x 192mm x 52mm)

Weight

1.6 lb (0.7 kg)

Power Supply

Battery

Polymer Li-ion rechargeable battery,or 10V DC adaptor

Rechargeable Li-ion battery (included)

Battery Life

15 hours uninterrupted use

Battery life will be reduced when 24V is applied

Battery Charge

110V/220V external power adapter (included)

Pressure Specification(222A & 223A)

The 160A series Intelligent Digital Pressure Modules are available for gauge, vacuum and absolute pressure from -15 psi to 10,000 psi (-1 bar to

700 bar). Accuracy from 0.02% FS includes operation over 14°F to 122°F

(-10°C to 50°C), one year stability and calibration uncertainty. For detail specification refer to pressure modules datasheet.

Look us up on www.additel.com or call today (1)714-998-6899

HART Communication capability (223A)

Support HART

®

instrumentation

Display

3.5 inch TFT color screen

Misuse protection

Up to 30V voltage on any two sockets and up to

1A current on current sockets will not damage the calibrator. The calibrator will return to normal condition as soon as the voltage or current is removed.

Rechargeable battery

Rechargeable Li-ion battery for 15 hours uninterrupted use.

Battery life will be reduced when 24V is applied.

The rechargeable battery is replaceable.

Temperature Specification

Thermocouple Measurement and Source Accuracy

Measure and Simulate

Standard Temperature Range ( o

C)

S

R

B

K

N

E

J

T

C

D

G

L

U

IEC 584

IEC 584

IEC 584 0 to 1820

IEC 584

IEC 584

IEC 584

IEC 584

IEC 584

ASTM

E988

ASTM

E988

ASTM

E1751

-50 to

1768

-50 to

1768

-270 to

1372

-270 to

1300

-270 to

1000

-270 to

1200

-270 to

400

0 to 2315

0 to 2320

0 to 2315

-100 to 1300

-250 to -200

-200 to -100

-100 to 0

0 to 700

700 to 1000

-210 to -100

-100 to 1200

-250 to -200

-200 to 0

0 to 400

0 to 1000

1000 to 1800

1800 to 2315

0 to 100

100 to 1100

1100 to 2000

-50 to400

400 to 1000

1000 to1768

-50 to 200

200 to 500

500 to 1768

50 to 450

450 to 800

800 to 1820

-250 to -200

-200 to -100

-100 to 600

600 to 1372

-250 to -200

-200 to -100

2000 to 2320

0 to 200

200 to 400

400 to 1400

1400 to 2315

-200 to -100

-100 to 400

400 to 900

-200 to 0

0 to 600

Accuracy ( o

C)

Measure Source

0.2

0.5

0.7

1.0

0.5

0.4

0.6

0.2

0.3

0.3

0.8

0.4

0.4

0.6

0.3

0.2

0.2

0.2

0.2

0.2

0.4

0.2

0.9

2.4

0.5

0.4

0.7

0.6

1.0

0.4

0.3

0.4

1.5

0.5

1.0

0.6

0.7

1.4

0.6

0.6

3.8

0.9

0.2

0.5

0.9

1.4

0.5

0.5

0.9

0.4

0.3

0.4

0.9

0.4

0.5

0.7

0.3

0.2

0.3

0.3

0.2

0.3

0.4

0.3

1.3

2.4

0.5

0.5

1.0

0.7

1.1

0.5

0.3

0.5

1.6

0.6

1.1

0.6

0.8

1.4

0.6

0.7

3.8

0.9

SPECIFICATIONS

Measurement Accuracy

Measure and Simulate

Pt10(385)

Pt100(385)

Pt100(3916)

Pt100(3926)

Pt500(385)

Pt1000(385)

Cu10(427)

Cu50(428)

Cu100(428)

Ni120(672)

Ni100(618)

Standard

IEC 751

IEC 751

JIS 1604

IEC 751

IEC 751

-200 to 850

-200 to 850

-200 to 850

Minco Application Aid #18 -200 to 850

-200 to 850

-200 to 850

Minco Application Aid #18 -100 to 260

GOST 6651-94 -50 to 150

GOST 6651-94

Edison curve #7

DIN 43760

-50 to 150

-100 to 260

-100 to 260

Temperature Range (°C)

-100 to 200

200 to 600

600 to 850

-100 to 200

200 to 600

600 to 850

-100 to 200

200 to 600

600 to 850

-100 to 200

200 to 600

600 to 850

-100 to 200

200 to 600

600 to 850

-100 to 200

200 to 600

600 to 850

-100 to 260

-50 to 150

-50 to 150

-100 to 260

-100 to 260

ORDERING INFORMATION

Model Number

ADT221A

ADT222A

ADT223A

Accessories (included)

110V/220V external power adapter

Chargeable Li-ion battery

Test leads

Short circuit cable

9060 Pressure module connection cable

(only for 222A & 223A)

Manual

1 pc

1 pc

3 sets(6 pcs)

1 sets(2 pcs)

1 pc

1 pc

NIST traceable calibration certificate 1 pc

* Additel/Land software can be downloaded for free at www.additel.com

Measure (2W/3W)

0.65

0.82

0.96

0.15

0.26

0.34

0.26

0.33

0.20

0.32

0.15

0.26

0.33

0.15

0.40

0.1

0.2

0.27

Accuracy (°C)

Measure (4W)

0.60

0.72

0.82

0.1

0.16

0.20

0.16

0.20

0.16

0.22

0.1

0.16

0.20

0.1

0.27

0.05

0.10

0.14

0.61

0.56

0.17

0.13

0.12

0.07

0.08

0.09

0.05

0.06

Optional Accessories

Model number

9510

Description

ADT160A

(only for 222A & 223A) Intelligent Digital Pressure Modules

9060

(only for 222A & 223A) Pressure module connection cable

9050 USB to RS232 (DB-9 Male) Adapter

9080

9712

9816

9906

Cable kit (including TC plug, compensation cable, S,R,B,K,J,T,E,N)

Spare chargeable Li-ion battery for multifunction calibrator

110V/220V external power adapter for ADT22X and ADT672 calibrator

Carrying case for multifunction calibrator

Additel/Cal Task management software for multifunction calibrator

0.26

0.33

0.36

0.54

0.15

0.26

0.33

0.15

Source

0.65

0.82

0.96

0.15

0.26

0.34

0.67

0.25

0.42

0.54

0.61

0.17

0.12

0.07

0.08

Look us up on www.additel.com or call today (1)714-998-6899

35

Additel 160A

Intelligent Digital Pressure Modules

Precision accuracy to 0.005%RD + 0.005%FS

Pressure measurement accuracy of 0.02% FS

Pressure ranges to 40,000 psi (2,100 bar)

Fully temperature compensated accuracy

36

Gauge pressure Differential pressure

OVERVIEW

With advanced microprocessor technology and state-of-the-art silicon pressure sensors, the Additel 160A series

Intelligent Digital Pressure Module (IDPM) provides an accurate, reliable, and economic solution for wide range of pressure applications. It is loaded with functionality and remarkably easy to use. In order to reach the best performance, every silicon pressure sensor in the module has been specially aged, tested and screened before assembly. Designed as external pressure module for Additel 761 automated pressure calibrator and Additel 222A,

Additel 223A and Additel 780 calibrators, the Additel 160A IDPM is unmatched in performance and reliability.

FEATURES

Precision sensor measurement accuracy to 0.005%RD

+ 0.005%FS

Gauge pressure measurement accuracy of 0.02% FS

Absolute Pressure measurement accuracy of 0.1% FS

Pressure ranges to 40,000 psi (2,800 bar)

Advanced temperature compensation

NIST traceable calibration and data included

SPECIFICATIONS

Gauge types

Gauge pressure Differential Pressure

Compound pressure Absolute pressure

Pressure Ranges and Accuracy

Differential Pressure

P/N

DP1

DP2

Pressure Range

[1]

(inH

2

0) (mbar)

±1

±2

±2.5

±5.0

DP5

DP10

DP20

±5

±10

±20

DP30

DP50

±30

±50

DP150 ±150

DP300 ±300

±10

±25

±50

±75

±160

±350

±700

G

G

G

G

G

G

G

G

G

0.05

[2]

0.05

[2]

0.05

[2]

0.05

[2]

0.05

0.05

0.05

0.02

0.02

100×

100×

50×

20×

20×

20×

Burst

Pressure

Static

Pressure

Range

±10 psi

±10 psi

±10 psi

±10 psi

±10 psi

±10 psi

±10 psi

50 psi

50 psi

[1] FS specification applies to the span of the range. Accuracy includes 1 year stability.

[2] 0.05%FS accuracy (incl 6 months stability). One year accuracy is 0.05%FS calibration accuracy combined with 0.05%FS one year stability.

Look us up on www.additel.com or call today (1)714-998-6899

Gauge Pressure

[1]

P/N

V15

GP2

GP5

GP10

GP15

GP30

GP50

GP100

GP300

GP500

GP600

GP1K

GP2K

GP3K

GP5K

GP10K 10,000

GP15K 15,000

GP20K 20,000

GP25K 25,000

GP30K 30,000

GP36K 36,000

GP40K 40,000

500

600

1,000

2,000

3,000

5,000

15

30

50

100

300

Pressure Range

(psi) (bar)

-15 -1.0

2

5

10

0.16

0.35

0.7

1.0

2.0

3.5

7.0

20

700

1,000

1,400

1,600

2,000

2,500

2,800

140

200

350

35

40

70

Media

[2]

Accuracy(%FS)

G , L

G , L

G , L

G , L

G , L

G , L

G , L

G , L

G , L

G , L

G , L

G , L

G , L

G

G

G , L

G , L

G , L

G

G

G

G

Note:

[1]. Sealed gauge pressure for above 1000 psi

[2]. G=Gas, L=Liquid

0.02

0.05

0.05

0.1

0.1

0.1

0.1

0.02

0.02

0.02

0.02

0.02

0.02

0.02

0.02

0.02

0.02

0.02

0.02

0.05

0.05

0.02

Burst

Pressure

2x

1.5x

1.5x

1.5x

1.5x

1.1x

SPECIFICATIONS

Precision Quartz Sensors

[1]

- Absolute Pressure

P/N psia

Pressure Range bar.a

AP45Q

AP100Q

AP400Q

AP500Q

AP1KQ

AP2KQ

0 to 45

0 to 100

0 to 400

0 to 500

0 to 1,000

0 to 2,000

3.0

7.0

28

35

70

140

AP3KQ

0 to 3,000 200

[1] Contact Additel for other range options.

Additel 780 with ADT160A Pressure Module

Media

G

G

G

G

G

G

G

Accuracy

0.005% rdg + 0.005% FS

0.005% rdg + 0.005% FS

0.005% rdg + 0.005% FS

0.005% rdg + 0.005% FS

0.005% rdg + 0.005% FS

0.005% rdg + 0.005% FS

0.005% rdg + 0.005% FS

CP600

CP1K

CP2K

CP3K

CP5K

CP10K

CP10

CP15

CP30

CP50

CP100

CP300

CP500

Compound Pressure

P/N psig

Pressure Range bar.g

±10

±15

-15 to 30

-15 to 50

-15 to 100

-15 to 300

-15 to 500

-15 to 600

-15 to 1,000

-15 to 2000

-15 to 3,000

-15 to 5000

-15 to 10,000

±0.7

±1.0

-1 to 2.0

-1 to 3.5

-1 to 7.0

-1 to 20

-1 to 35

-1 to 40

-1 to 70

-1 to 140

-1 to 200

-1 to 350

-1 to 700

Media

G,L

G,L

G,L

G,L

G

G

G

G

G,L

G,L

G,L

G,L

G,L

Accuracy

0.02% FS

0.02% FS

0.02% FS

0.02% FS

0.02% FS

0.02% FS

0.02% FS

0.02% FS

0.02% FS

0.02% FS

0.02% FS

0.02% FS

0.02% FS

Burst

Pressure Rating

Over Pressure

3x

3x

3x

3x

3x

3x

3x

1.2x

1.2x

1.2x

1.03x

1.1x

1.1x

1.1x

Burst

Pressure Rating

Over Pressure

3x

3x

3x

3x

3x

3x

3x

3x

3x

3x

3x

3x

2x

1.2x

1.2x

1.2x

1.2x

1.2x

1.2x

1.2x

1.2x

1.2x

1.2x

1.2x

1.2x

1.2x

Look us up on www.additel.com or call today (1)714-998-6899

37

AP5

AP10

AP15

AP30

AP50

AP100

AP300

AP500

AP1K

AP3K

AP5K

Absolute Pressure

P/N

500

1,000

3,000

5,000

Pressure Range

(psi) (bar)

5 0.35

10

15

30

50

100

300

0.7

1.0

2.0

3.5

7.0

20

35

70

200

350

Media Accuracy(%FS)

Burst

Pressure

G

G

G , L

G , L

G

G

G

G , L

G , L

G , L

G , L

0.1

0.1

0.1

0.1

0.1

0.05 (0.1)

0.05 (0.1)

0.05 (0.1)

0.05 (0.1)

0.05 (0.1)

0.05 (0.1)

ORDERING INFORMATION

Model Number

ADT160A

Model

02

Accuracy:

01-0.005%rdg+0.005% of full scale

02-0.02% of full scale

05-0.05% of full scale

10-0.1% of full scale

Pressure range P/N:

See pressure range table

GP300 PSI

Range type:

PSI - range by psi

BAR - range by bar

Pressure port type:

N - 1/4NPT male

N2 - 1/2NPT male

B - 1/4BSP male

B2 - 1/2BSP male

M - M20 X 1.5 male

N

Additel 223A with ADT160A Pressure Module

SPECIFICATIONS

Temperature compensation

Operating temperature

Storage temperature

Relative humidity

Pressure connections

(for external use only)

Enclosure

(for external use only)

Dimensions (Dia x H)

Weight

Warranty

CPXXX

Standard Accuracy

DPXXX GPXXX

-10°C to 50°C (14°F to 122°F)

-10°C to 50°C (14°F to 122°F)

-20°C to 70°C (-4°F to 158°F)

95% RH

1/4NPT, 1/2NPT, 1/4BSP, 1/2BPS, M20x15

SS enclosure

33 mm x 123 mm (1.3” x 4.84”)

0.4 kg (0.99 lb)

1 Year

Accessories included

NIST Traceable Calibration Certificate

Optional Accessories

Model number

Description

9060 Pressure module connection cable

Picture

Precision Accuracy

AP3KQ AP1KQ AP100Q

0°C to 50°C (32°F to 122°F)

0°C to 50°C (32°F to 122°F)

-20°C to 70°C (-4°F to 158°F)

95% RH

1/4NPT, 1/2NPT, 1/4BSP, 1/2BSP, M20x15

SS enclosure

44 mm x 220mm (1.7” x 8.7”)

0.8 kg (1.8 lb)

1 Year

60 mm x 190 mm (2.4” x7.5”)

1.2 kg (2.6 lb)

1 Year

38

Look us up on www.additel.com or call today (1)714-998-6899

Pressure Test/Calibration Pumps

Selection Guide

Model Photo Type Range in psi

Additel 901 Pneumatic (-6 to 6) psi

Range in bar

(-0.4 to 0.4) bar

Media

Adjustment

Resolution

Weight

See

Page

Air 0.001 mbar 3.5 lb P40

Additel 912

Additel 914

Additel 916

Additel 917

Pneumatic (-14 to 60) psi (-0.95 to 4) bar Air 0.001 mbar 6.2 lb P41

Pneumatic (-14 to 375) psi (-0.95 to 25) bar Air 0.1 mbar 3.3 lb P42

Pneumatic (-14 to 600) psi (-0.95 to 40) bar Air 0.1 mbar 5.9 lb P43

Pneumatic (-14 to 1,000) psi (-0.95 to 70) bar Air 0.1 mbar 5.7 lb P44

HOT

Additel 918

Additel 919A

Pneumatic (-14 to 1,500) psi (-0.95 to 100) bar Air 0.1 mbar 5.7 lb P45

Pneumatic (-14 to 2,000) psi (-0.95 to 140) bar Air 0.1 mbar 14.3 lb P46

HOT

Additel 920

Additel 925

Additel 927

Additel 928

Additel 936

Additel 937

Additel 938

Pneumatic (-14 to 3,000) psi (-0.95 to 200) bar Air 0.1 mbar 14.3 lb P48

Hydraulic

Hydraulic

Hydraulic

Hydraulic

Hydraulic

Hydraulic

(-12.5 to 6,000) psi (-0.85 to 400) bar

Oil/

Water

[1]

1 mbar

(-12.5 to 10,000) psi

(-0.85 to 700) bar

Oil/

Water

[1]

1 mbar

(0 to 15,000) psi

(0 to 1,000) bar

Oil/

Water

[1]

1 mbar

(-12.5 to 15,000) psi

(-0.85 to 1,000) bar

Oil

(-12.5 to 15,000) psi

(-0.85 to 1,000) bar

Oil

[2]

1 mbar

1 mbar

(-12.5 to 15,000) psi

(-0.85 to 1,000) bar

Water 1 mbar

3.7 lb

7 lb

8.6 lb

35.2 lb

P51

35.2 lb P54

35.2 lb

P49

P52

P53

P55

Hydraulic (0 to 15,000) psi (0 to 1,000) bar Oil 1 mbar 28.7 lb P56

NEW

Additel 946

HOT

Additel 949 Hydraulic

(-12.5 to 40,000) psi

(-0.85 to 2,800) bar

Oil 1 mbar 35.2 lb P57

NEW

Additel 959 Hydraulic (0 to 40,000) psi (0 to 2,800) bar Oil 1 mbar 28.7 lb P58

[1] Oil is default media liquid. Pump with water as media to be ordered

specially.

[2] Oil, compatible to phosphoric acid fluid or skydrol oil.

Look us up on www.additel.com or call today (1)714-998-6899

39

40

Additel 901

Low Pressure Test Pump

Generate 6 psi (0.4 bar) vacuum to 6 psi (0.4 bar) pressure

Portable, only 3.5 lb

Great stability and high resolution

Minimal maintenance

Hand-tight quick connectors

OVERVIEW

The 901 Low Pressure Test Pump is a hand operated pressure pump designed to generate pressures from -6 psi (-0.4 bar) to 6 psi (0.4 bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up to 0.1 Pa (0.001 mbar). The 901 is a very stable low pressure calibrator. It makes use of an isothermal bellows chamber which is designed for reducing the possible effects of environmental temperature change. Most pumps make use of a check valve (non-returning valve) and are not well insulated which will cause large fluctuations in pressure with a change in ambient temperature or when the unit is touched. The 901 does not use a check valve and is remarkably stable. Two hand-tight connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 901 is an ideal comparison test pump for low pressure applications.

FEATURES

Portable: Only 3.5 lb (1.6 kg)

Adjustment Resolution

0.1Pa (0.001 mbar); Specially designed screw press for fine pressure adjustment.

Great Stability

Isothermal chamber: the pressure chamber is insulated to reduce the influence from environmental temperature changes.

Specially designed bellows minimize leakage to guarantee excellent stability.

Durable and Minimal Maintenance

Without non-returning valve that is usually used on troublesome hand pump.

Easy-to-use

Pressure could be set and adjusted precisely and quickly through a simple turn of the handle.

Hand-tight Quick Connectors

Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.

SPECIFICATIONS

Media: Air.

Generated Pressure Range

6 psi (0.4 bar) vacuum to 6 psi (0.4 bar) positive pressure.

Adjustment Resolution: 0.1 Pa (0.001 mbar).

Material:

Ram/adapters: SS

Body: SS, aluminum

Seals: Buna-N, PTFE, Copper Alloy

Connection

Hand-tight connectors for both test gauge and reference gauge.

1/4NPT female, 1/2NPT female, 1/4BSP female, 1/2BSP female, or M20X1.5 female

Dimensions: Height: 5.7'' (145mm)

Base: 9.65'' (245 mm) x 6.50'' (165mm)

Weight: 3.5 lb (1.6 kg).

Warranty: 1 year.

Optional Accessories

ORDERING INFORMATION

Model number Description

Model Number

ADT901 N

ADT901-X-kit

ADT901-HD

Test kit for ADT901 (barb fitting, connection hoses, and adapters).

X=connection type e.g. N-1/4NPTM, N2-1/2NPTM, B-1/4BSPM, B2-1/2BSPM,

M-M20X1.5M.

Holder for Additel 681 differential gauge or 672 differential calibrator.

Model

Pressure port type:

ADT102

Adapters and fittings, 1/4NPT male to various male and female connection (25 pcs). More information shown on page 61.

N -

1/4

NPT female

N2 - 1/2NPT female

B - 1/4BSP female

ADT103

Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.

B2 - 1/2BSP female

M-M20X1.5 female

ADT100-HTK

9901-901

Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT (1/8NPT,

1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) female hand-tight quick connector.

More information shown on page 63.

Carrying Case for one ADT901 pump and two ADT681 gauges or ADT672 calibrators

Accessories included

O-ring: 20 pcs

ADT901-MK Maintenance kit for Additel 901 pump

Manual: 1 pc

9240 DP gauge holder, rubber

Note: For O

2

-clean applications contact Additel.

Look us up on www.additel.com or call today (1)714-998-6899

Additel 912

Low Pressure Test Pump

Generate 95% vacuum to 60 psi (4 bar) pressure

Portable

Great stability and high resolution

Minimal maintenance

Hand-tight quick connectors

OVERVIEW

The 912 Pneumatic Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 60 psi (4 bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up to 0.1 Pa (0.001 mbar). The 912 is a very stable low pressure calibrator. It makes use of an isothermal bellows chamber which is designed for reducing the possible effects of environmental temperature change. Most pumps make use of a check valve (non-returning valve) and are not well insulated which will cause large fluctuations in pressure with a change in ambient temperature or when the unit is touched. The 912 does not use a check valve and is remarkably stable. Two hand-tight connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 912 is an ideal comparison test pump for low pressure application.

FEATURES

Portable: Only 6.2 lb (2.8 kg)

Adjustment Resolution

0.1Pa (0.001 mbar)

High-quality screw press for fine pressure adjustment

Great Stability

Isothermal chamber: the pressure chamber is insulated to reduce the influence from environmental temperature changes

Specially designed bellows minimize leakage to guarantee excellent stability

Shut-off valve closes the air in the isothermal chamber during calibration

Durable and Minimal Maintenance

Built-in gas-liquid isolator protects the pump from moisture and dirt

Easy-to-use

Hand-tight Quick Connectors

Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches

SPECIFICATIONS

Media: Air.

Generated Pressure Range

95% vacuum to 60 psi (4bar) positive pressure

Adjustment Resolution: 0.1 Pa (0.001 mbar).

Material: Ram/adapters: SS

Body: SS, aluminum

Seals: Buna-N, PTFE, Copper Alloy

Piston volume: 21 ml (1.3 in

Connection

3

)

Hand-tight connectors for both test gauge and reference gauge.

1/4NPT female, 1/2NPT female, 1/4BSP female, 1/2BSP female, or M20X1.5 female

Dimensions

Height: 5.51'' (140 mm)

Base: 10.75'' (273 mm) x 10.16'' (258 mm)

Weight: 6.2 lb (2.8 kg).

Warranty: 1 year

ORDERING INFORMATION

Model Number

ADT912 N

Model

Pressure port type:

N -

1/4

NPT female

N2 - 1/2NPT female

B - 1/4BSP female

B2 - 1/2BSP female

M - M20X1.5 female

Accessories included

O-ring: 20 pcs

Manual: 1 pc

Optional Accessories

Model number

ADT912-X-kit

ADT102

ADT103

ADT100-HTK

9904-912

Description

Test kit for ADT912 (barb fitting, connection hoses, and adapters).

X=connection type e.g. N-1/4NPTM, N2-1/2NPTM, B-1/4BSPM, B2-1/2BSPM,

M-M20X1.5M.

Adapters and fittings, 1/4NPT male to various male and female connection (25 pcs). More information shown on page 61.

Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.

Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT (1/8NPT,

1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) female hand-tight quick connector.

More information shown on page 63.

Carrying Case for one 912 pump and two 681 gauges or 672 calibrators.

ADT912-MK Maintenance kit for Additel 912 pump

9240 DP gauge holder, rubber

Note: For O

2

-clean applications contact Additel.

Look us up on www.additel.com or call today (1)714-998-6899

41

Additel 914

Handheld Pneumatic Pressure Test Pump

Generate 95% vacuum to 375 psi (25 bar) pressure

Portable, only 3.3 lb

Great stability and high resolution

Minimal maintenance

Hand-tight quick connectors

OVERVIEW

The 914 Pneumatic Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 375 psi (25 bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up to10 Pa (0.1 mbar). A specially designed shut-off valve makes the pressure as stable as possible during calibration. A built-in gas-liquid isolator protects the pump from moisture and dirt to reduce the need for maintenance.

Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 914 is an ideal comparison test pump for pressure instruments calibration.

FEATURES

Portable:

Only 3.3 lb (1.5 kg)

Adjustment Resolution

10 Pa (0.1 mbar)

High-quality screw press for fine pressure adjustment

Great Stability

A specially designed shut-off valve makes the pressure as stable as possible during calibration

Durable and Minimal Maintenance

Built-in gas-liquid isolator protects the pump from moisture and dirt

Easy-to-use

Hand-tight Quick Connectors

Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches

SPECIFICATIONS

Media: Air.

Generated Pressure Range: 95% vacuum to 375 psi (25 bar) positive pressure

Adjustment Resolution: 10 Pa (0.1 mbar).

Material: Ram/adapters: SS

Body: SS, aluminum

Seals: Buna-N, PTFE, Copper Alloy

Piston volume: 21 ml (1.3 in

Connection

3

)

Hand-tight connectors for both test gauge and reference gauge.

1/4NPT female, 1/2NPT female, 1/4BSP female,

1/2BSP female, or M20X1.5 female

Dimensions

Height: 5.12'' (130 mm)

Base: 9.45'' (240 mm) x 4.72'' (120 mm)

Weight: 3.3 lb (1.5 kg).

Warranty: 1 year

42

ORDERING INFORMATION

Model Number

ADT914

Model

N

Pressure port type:

N -

1/4

NPT female

N2 - 1/2NPT female

B - 1/4BSP female

B2 - 1/2BSP female

M - M20X1.5 female

Accessories included

O-ring: 20 pcs

Manual: 1 pc

Optional Accessories

Model number

ADT102

ADT103

ADT100-HTK

Description

Adapters and fittings, 1/4NPT male to various male and female connection

(25 pcs). More information shown on page 61.

Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.

Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT

(1/8NPT, 1/2NPT, 1/4BSP, 1/2 BSP, or M20X1.5) female hand-tight quick connector. More information shown on page 63.

Carrying Case for one 914 pump and two 681 gauges or 672 calibrators 9901-914

ADT914-MK Maintenance kit for Additel 914 pump

Note: For O

2

-clean applications contact Additel.

Look us up on www.additel.com or call today (1)714-998-6899

Additel 916

Pneumatic Pressure Test Pump

Generate 95% vacuum to 600 psi (40 bar) pressure

Portable, only 5.9 lb

Great stability and high resolution

Minimal maintenance

Hand-tight quick connectors

OVERVIEW

The 916 Pneumatic Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 600 psi (40 bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up to 10 Pa (0.1 mbar). A specially designed shut-off valve makes the pressure as stable as possible during calibration. A built-in gas-liquid isolator protects the pump from moisture and dirt to reduce the need for maintenance.

Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 916 is an ideal comparison test pump for pressure instruments calibration.

FEATURES

Portable

Only 5.9 lb (2.7 kg)

Adjustment Resolution

10 Pa (0.1 mbar)

High-quality screw press for fine pressure adjustment

Great Stability

A specially designed shut-off valve makes the pressure as stable as possible during calibration.

Durable and Minimal Maintenance

Built-in gas-liquid isolator protects the pump from moisture and dirt.

Easy-to-use

Hand-tight Quick Connectors

Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.

SPECIFICATIONS

Media: Air.

Generated Pressure Range

95% vacuum to 600 psi (40 bar) positive pressure

Pressure Resolution: 10 Pa (0.1 mbar).

Material

Ram/adapters: SS

Body: SS, aluminum

Seals: Buna-N, PTFE, Copper Alloy

Piston volume: 21 ml (1.3 in

Connection

3

)

Hand-tight connectors for both test gauge and reference gauge.

1/4NPT female, 1/2NPT female, 1/4BSP female, 1/2BSP female, or M20X1.5 female

Dimensions

Height: 5.5'' (140 mm)

Base: 12.4'' (315 mm) x 7.8'' (198 mm)

Weight: 5.9 lb (2.7 kg).

Warranty:1 year

ORDERING INFORMATION

Model Number

ADT916 N

Model

Pressure port type:

N -

1/4

NPT female

N2 - 1/2NPT female

B - 1/4BSP female

B2 - 1/2BSP female

M - M20X1.5 female

Accessories included

O-ring: 20 pcs

Manual: 1 pc

Optional Accessories

Model numberel Description

ADT102

ADT103

ADT100-HTK

9904-916

Adapters and fittings, 1/4NPT male to various male and female connection

(25 pcs). More information shown on page 61.

Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.

Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT

(1/8NPT, 1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) female hand-tight quick connector. More information shown on page 63.

Carrying Case for one ADT916 pump and two ADT681 gauges or ADT672 calibrators

ADT916-MK Maintenance kit for Additel 916 pump

Note: For O

2

-clean applications contact Additel.

Look us up on www.additel.com or call today (1)714-998-6899

43

Additel 917

Pneumatic Pressure Test Pump

Generate 95% vacuum to 1,000 psi (70 bar) pressure

Portable, only 5.7 lb

Great stability and high resolution

Minimal maintenance

Hand-tight quick connectors

OVERVIEW

The 917 Pneumatic Pressure Test Pump is a hand operated pressure pump designed to generate pressure from

95% vacuum to 1,000 psi (70 bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up to 10 Pa (0.1 mbar). A specially designed shut-off valve makes the pressure as stable as possible during calibration. A built-in gas-liquid isolator protects the pump from moisture and dirt to reduce the need for maintenance. The 917 can be special ordered to comply with oxygen free applications. Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for

PTFE tape or wrenches. The 917 is an ideal comparison test pump for pressure instruments calibration.

FEATURES

Portable

Only 5.7 lb (2.6 kg)

High Resolution

10 Pa (0.1 mbar)

High-quality screw press for fine pressure adjustment

Great Stability

A specially designed shut-off valve makes the pressure as stable as possible during calibration.

Durable and Minimal Maintenance

Built-in gas-liquid isolator protects the pump from moisture and dirt.

Easy-to-use

Pressurized to desired pressure by the lever directly and make fine adjustment. No high-pressurized valve needed.

Hand-tight Quick Connectors

Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.

SPECIFICATIONS

Media: Air.

Generated Pressure Range

95% vacuum to 1,000 psi (70 bar) positive pressure

Adjustment Resolution: 10 Pa (0.1 mbar).

Material: Ram/adapters: SS

Body: SS, aluminum

Seals: Buna-N, PTFE, Copper Alloy

Piston volume: 27 ml (1.6 in

3

)

Connection:

Hand-tight connectors for both test gauge and reference gauge.

1/4NPT female, 1/2NPT female, 1/4BSP female,

1/2BSP female, or M20X1.5 female

Dimensions:

Height: 5.5'' (140 mm)

Base: 12.4" (315 mm) x 7.8" (198 mm)

Weight: 5.7 lb (2.6 kg).

Warranty: 1 year

44

ORDERING INFORMATION

Model Number

ADT917 N

Model

Pressure port type:

N -

1/4

NPT female

N2 - 1/2NPT female

B - 1/4BSP female

B2 - 1/2BSP female

M - M20X1.5 female

Accessories included

O-ring: 20 pcs

Manual: 1 pc

Optional Accessories

Model number

ADT102

ADT103

ADT100-HTK

Description

Adapters and fittings, 1/4NPT male to various male and female connection

(25 pcs). More information shown on page 61.

Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.

Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT

(1/8NPT, 1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) female hand-tight quick connector. More information shown on page 63.

Carrying Case for one 917 pump and two 681 gauges or 672 calibrators 9904-917

ADT917-MK Maintenance kit for Additel 917 pump

Note: For O

2

-clean applications contact Additel.

Look us up on www.additel.com or call today (1)714-998-6899

Additel 918

Pneumatic Pressure Test Pump

Generate 95% vacuum to 1,500 psi (100 bar) pressure

Portable, only 5.7 lb

Great stability and high resolution

Minimal maintenance

Hand-tight quick connectors

OVERVIEW

The 918 Pneumatic Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 1,500 psi (100 bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up to 10 Pa (0.1 mbar). A specially designed shut-off valve makes the pressure as stable as possible during calibration. A built-in gas-liquid isolator protects the pump from moisture and dirt to reduce the need for maintenance.

The 918 can be special ordered to comply with oxygen free applications. Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The

918 is an ideal comparison test pump for pressure instruments calibration.

FEATURES

Portable

Only 5.7 lb (2.6 kg)

High Resolution

0.001psi (10 Pa , 0.1 mbar)

High-quality screw press for fine pressure adjustment

Great Stability

A specially designed shut-off valve makes the pressure as stable as possible during calibration.

Durable and Minimal Maintenance

Built-in gas-liquid isolator protects the pump from moisture and dirt.

Easy-to-use

Pressurize to desired pressure by the pump lever directly, and then make fine adjustment. No highpressure valve needed.

Hand-tight Quick Connectors

Allows easy connection and disconnection to the test pump without the need for PTFE tape or wrenches.

SPECIFICATIONS

Media: Air.

Generated Pressure Range

95% vacuum to 1,500 psi (100 bar) positive pressure

Adjustment Resolution: 0.001 psi (10 Pa , 0.1 mbar).

Material: Ram/adapters: SS

Body: SS, aluminum

Seals: Buna-N, FTM, PTFE, Copper Alloy

Piston volume: 27 ml (1.6 in 3

)

Connection: Hand-tight connectors for both test gauge and reference gauge.

1/4NPT female, 1/2NPT female, 1/4BSP female,

1/2BSP female, or M20X1.5 female

Dimensions:

Height: 5.5'' (140 mm)

Base: 12.4" (315 mm) x 7.8" (198 mm)

Weight: 5.7 lb (2.6 kg).

Warranty: 1 year

ORDERING INFORMATION

Model Number

ADT918 N

Model

Pressure port type:

N -

1/4

NPT female

N2 - 1/2NPT female

B - 1/4BSP female

B2 - 1/2BSP female

M - M20X1.5 female

Accessories included

O-ring: 20 pcs

Manual: 1 pc

Optional Accessories

Model number

ADT102

ADT103

ADT100-HTK

Description

Adapters and fittings, 1/4NPT male to various male and female connection

(25 pcs). More information shown on page 61.

Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.

Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT

(1/8NPT, 1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) female hand-tight quick connector. More information shown on page 63.

Carrying Case for one 918 pump and two 681 gauges or 672 calibrators 9904-918

ADT918-MK Maintenance kit for Additel 918 pump

Note: For O

2

-clean applications contact Additel.

Look us up on www.additel.com or call today (1)714-998-6899

45

46

Additel 919A

High Pressure Test Pump

Generate 95% vacuum to 2,000 psi (140 bar) pressure

Generate 2,000 psi (140 bar) in 30 seconds

Minimal maintenance

Hand-tight quick connectors

First one in the world

OVERVIEW

The 919A High Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 2,000 psi (140 bar). With a long lever, it just takes 30 seconds to reach 2,000 psi (140 bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up to 0.001 psi (10 Pa , 0.1 mbar).

A specially designed shut-off valve makes the pressure as stable as possible during calibration. A built-in gas-liquid isolator protects the pump from moisture and dirt to reduce the need for maintenance. The residual liquid in the pump introduced from the devices under test will be collected and then pushed out during pressure release. Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for

PTFE tape or wrenches. The 919A is an ideal comparison test pump for pressure instruments calibration.

FEATURES

High Efficiency

Generate 2,000 psi (140 bar) in 30 seconds.

Adjustment Resolution

0.001 psi (10 Pa , 0.1 mbar).

High-quality screw press for fine pressure adjustment.

Great Stability

A specially designed shut-off valve makes the pressure as stable as possible during calibration.

Durable and Minimal Maintenance

Built-in gas-liquid isolator protects the pump from moisture and dirt.

The residual liquid in the pump introduced from devices under test will be collected and then pushed out and collected during pressure release.

Anticorrosive and wear resistant material are used to improve the reliability further.

Hand-tight Quick Connectors

Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.

SPECIFICATIONS

Media: Air.

Generated Pressure Range: 95% vacuum to 2,000 psi

(140 bar) positive pressure

Adjustment Resolution: 10 Pa (0.1 mbar/0.0015 psi)

Material: Ram/adapters: SS

Body: SS, aluminum

Seals: Buna-N, PTFE, Copper Alloy

Piston volume: 60 ml (3.7 in

3

)

Connection

Hand-tight connectors for both test gauge and reference gauge.

1/4NPT female, 1/2NPT female, 1/4BSP female,

1/2BSP female, or M20X1.5 female

Dimensions:

Height: 7.00'' (178 mm);

Base: 21.26' (540 mm) x 10.63'' (270 mm).

Weight: 14.3 lb (6.5 kg).

Warranty: 1 year

ORDERING INFORMATION

Model Number

ADT919A N

Model

Pressure port type:

N -

1/4

NPT female

N2 - 1/2NPT female

B - 1/4BSP female

B2 - 1/2BSP female

M - M20X1.5 female

Accessories included

O-ring: 20 pcs

Manual: 1 pc

Optional Accessories

Model number

ADT102

ADT103

ADT100-HTK

Description

Adapters and fittings, 1/4NPT male to various male and female connection

(25 pcs). More information shown on page 61.

Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.

Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT

(1/8NPT, 1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) female hand-tight quick connector. More information shown on page 63.

Carrying Case for one 919A pump and two 681 gauges or 672 calibrators 9909-919A

ADT919A-MK Maintenance kit for Additel 919A pump

Note: For O

2

-clean applications contact Additel.

Look us up on www.additel.com or call today (1)714-998-6899

Application Note

Improved Methods for High Pressure Pneumatic Calibrations in the Field

Are you tired of dragging a nitrogen bottle and dead weight tester out to the field to perform pneumatic high pressure calibrations? Does it trouble you to use a hydraulic pump or dead weight tester for your gas gauges every time you have to go above 600 psi? This application note details the limitations to traditional methods and provides a solution to calibration of gas gauges up to 3,000 psi (200 bar) with a field-ready calibration tool.

Limitations with Traditional Methods

Traditional methods for performing high pressure gas gauge calibrations in the field require the use of a controller or comparison systems and a nitrogen bottle. This solution typically provides the performance needed to do the job but adds a considerable inconvenience in having to transport several pieces of heavy equipment to the calibration site.

Not to mention the time and effort in setting up the system. Dead weight testers and hydraulic pumps have also been used as a solution. Hydraulic pumps are problematic for this application as the liquid can damage the gas gauge you are attempting to calibrate. It is common that these hydraulic comparison pumps also lack the stability and resolution required to calibrate many gas gauges. Dead weight testers typically have the accuracy required but will require a gas supply for high pressure pneumatic applications. If the dead weight tester uses hydraulic fluid as the medium it will achieve much higher pressures but has similar drawbacks as hydraulic pumps.

A More Practical Solution

Additel developed their high pressure pneumatic pumps specifically to address high pressure gas calibrations in the field. The Additel 919A goes to 2,000 psi (140 bar) and the 920 goes to 3,000 psi (200 bar) without the use of hydraulic fluids or the need for a gas supply. Each pump can also generate to 95% of vacuum. The ADT920 will generate

3,000 psi (200 bar) in 40 seconds and the pump weighs about 14 lbs (6.5 kg) which makes it easy to take to the field.

The high pressure range, portability, and speed to pressure are not the only things that make this series of pumps unique. The Additel pneumatic pump design allows for high stability and resolution to 0.001 psi (0.1 mbar). Like many pumps on the market, the ADT919A and the ADT920 use a check valve, also referred to as a non-returning valve, to protect the pump from contaminants that could cause damage. However, we've seen with most pumps on the market that the check valve tends to lose its seal over time which causes unstable measurements. The Additel design incorporates a high-quality isolation valve and screw press which allows for you to isolate the calibration volume from the check valve and achieve very stable measurements and resolution to 0.001 psi (0.1 mbar).

The diagram below illustrates the pump construction.

The method of operation is as follows: To generate pressure, use the pump handle on top of the unit. When you've generated 70% - 80% of the desired pressure with the pump handle, then close the isolation valve (this isolates the calibration volume from the pump handle and check valve). Next, use the fine-adjust screw press to generate the remaining pressure. Each pump comes with two hand-tight, quick-connect pressure ports that do not require the use of PTFE tape or wrenches. Combine this pump with any of our digital pressure gauges and you have an accurate, portable and practical field calibration solution for gas calibrations up to 3,000 psi (200 bar).

Conclusion

Traditional solutions for high pressure gas calibrations are not convenient or practical for field applications or they require the use of hydraulic fluids which could damage the sensor being tested. The Additel 919A and 920 pneumatic pressure pumps solve many of the problems that exist with traditional solutions and provide a reliable, field-ready, accurate and affordable solution to meet your needs!

Look us up on www.additel.com or call today (1)714-998-6899

47

48

Additel 920

High Pressure Test Pump

Generate 95% vacuum to 3,000 psi (200 bar) pressure

Generate 3,000 psi (200 bar) in 40 seconds

Minimal maintenance

Hand-tight quick connectors

First one in the world

OVERVIEW

The 920 High Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 3,000 psi (200 bar). With a long lever, it just takes 40 seconds to reach 3,000 psi (200 bar). A highquality screw press is designed for fine pressure adjustment, with an adjustment resolution up to 10 Pa (0.1 mbar).

A specially designed shut-off valve makes the pressure as stable as possible during calibration. A built-in gas-liquid isolator protects the pump from moisture and dirt to reduce the need for maintenance. The residual liquid in the pump introduced from devices under test will be pushed out and collected during pressure release. Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 920 is an ideal comparison test pump for pressure instruments calibration.

FEATURES

High Efficiency

Generate 3,000 psi (200 bar) in 40 seconds.

Adjustment Resolution

0.001 psi (10 Pa, 0.1 mbar).

High-quality screw press for fine pressure adjustment.

Great Stability

A specially designed shut-off valve makes the pressure as stable as possible during calibration.

Durable and Minimal Maintenance

Built-in gas-liquid isolator protects the pump from moisture and dirt.

The residual liquid in the pump introduced from devices under test will be collected and then pushed out and collected during pressure release.

Anticorrosive and wear resistant material are used to improve the reliability further.

Hand-tight Quick Connectors

Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.

SPECIFICATIONS

Media: Air.

Generated Pressure Range

95% vacuum to 3,000 psi (200 bar) positive pressure

Adjustment Resolution: 10 Pa (0.1 mbar/0.0015 psi)

Material: Ram/adapters: SS

Body: SS, aluminum

Seals: Buna-N, F357, PTFE, Copper Alloy

Piston volume: 60 ml (3.7 in

3

)

Connection

Hand-tight connectors for both test gauge and reference gauge.

1/4NPT female, 1/2NPT female, 1/4BSP female,

1/2BSP female, or M20X1.5 female

Dimensions:

Height: 7.00'' (178 mm);

Base: 21.26' (540 mm) x 10.63'' (270 mm).

Weight: 14.3 lb (6.5kg).

Warranty:: 1 year

ORDERING INFORMATION

Model Number

ADT920 N

Model

Pressure port type:

N -

1/4

NPT female

N2 - 1/2NPT female

B - 1/4BSP female

B2 - 1/2BSP female

M - M20X1.5 female

Accessories included

O-ring: 20 pcs

Manual: 1 pc

Optional Accessories

Model number

ADT102

ADT103

ADT100-HTK

Description

Adapters and fittings, 1/4NPT male to various male and female connection

(25 pcs). More information shown on page 61.

Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.

Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT

(1/8NPT, 1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) female hand-tight quick connector. More information shown on page 63.

Carrying Case for one 920 pump and two 681 gauges or 672 calibrators 9909-920

ADT920-MK Maintenance kit for Additel 920 pump

Note: For O

2

-clean applications contact Additel.

Look us up on www.additel.com or call today (1)714-998-6899

Additel 925

Handheld Hydraulic Pressure Test Pump

Generate 85% vacuum to 6,000 psi (400 bar) pressure

Portable, only 3.7 lb

Minimal maintenance

Increase and decrease pressure smoothly

Hand-tight quick connectors

OVERVIEW

The 925 Hydraulic Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 85% vacuum to 6,000 psi (400 bar). With the patented screw press technology, the high pressure can be easily generated, as well as increased and decreased smoothly. With no check valve (non-returning valve), the 925 avoids the troublesome leakage issues that is usually experienced with most hand pumps and allows for minimal maintenance. Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for

PTFE tape or wrenches. The 925 is an ideal comparison test pump for calibrating pressure measuring instruments such as test gauges, indicators or transducers in the field or laboratory.

FEATURES

Portable

Only 3.7 lb (1.7 kg)

Durable and Minimal Maintenance

Patented screw press technology, without non-returning valve inside that is usually used on troublesome hand pumps.

Easy-to-use

The high pressure can be generated easily, as well as increased and decreased smoothly.

Extremely Low Leakage

Patented screw press technology, replaces troublesome check valves (non-returning valve) used in most hand pumps which practically eliminates leakage.

Hand-tight Quick Connectors

Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.

SPECIFICATIONS

Media: Oil or deionized water.

(Oil is default media liquid. Pump with water as media to be ordered specifically)

Reservoir capacity: 200 ml (12.2 in

Pressure Range

3

)

85% vacuum to 6,000 psi (400 bar) positive pressure.

Material: Ram/adapters: SS

Body: SS,aluminum

Seals: Buna-N, PTFE, Copper Alloy

Connection

Hand-tight connectors for both test gauge and reference gauge.

1/4NPT female, 1/2NPT female, 1/4BSP female,

1/2BSP female, or M20X1.5 female

Dimensions: Height: 4.72'' (120 mm)

Base: 9.84'' (250 mm) x 5.51'' (140 mm)

Weight: 3.7 lb (1.7 kg).

Warranty: 1 year

Piston volume

Low pressure piston: 18 ml (1.1 in

3

)

High pressure piston: 0.9 ml (0.05 in

3

)

ORDERING INFORMATION

Model Number

ADT925 N

Model Pressure port type:

N -

1/4

NPT female

N2 - 1/2NPT female

B - 1/4BSP female

B2 - 1/2BSP female

M - M20X1.5 female

Accessories included

Mineral oil,1 bottle (250 ml)*

O-ring: 20 pcs

Manual: 1 pc

* When water media is not requested

Optional Accessories

Model number

9201

ADT102

ADT103

ADT100-HTK

9901-925

ADT925-MK

Description

Oil, Diethylhexyl Sebacate, 1 liter (1 quart)

Adapters and fittings, 1/4NPT male to various male and female connection

(25 pcs). More information shown on page 61.

Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.

Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT

(1/8NPT, 1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) female hand-tight quick connector. More information shown on page 63.

Carrying Case for one 925 pump and two 681 gauges or 672 calibrators

Maintenance kit for Additel 925 pump

Look us up on www.additel.com or call today (1)714-998-6899

49

50

Application Note

Considerations for Hydraulic High Pressure Calibrations

If you are doing high pressure, hydraulic calibrations there are a few things that you'll need to consider which will make your life a little easier and help you produce stable measurements. This application note focuses on considerations for pressure calibrations using a high pressure hydraulic pump to generate the pressure.

Getting Started

To produce stable and high pressure measurements using a hydraulic calibration pump, the gas within the calibration system needs to be removed.

Hydraulic test pumps use various types of fluids to generate high pressures.

Because gas is much more compressible than liquid, purging most if not all the gas out of the system will allow for maximum pressures to be generated.

The following steps describe the procedure to purge the gas from an Additel test pump:

1. Ensure the pump, reference standard, and device under test (DUT) are securely connected to the calibration pump.

2. Close the vent valve and screw out the main screw press. You should see a vacuum being pulled on your reference and DUT

(assuming the reference and the DUT are able to be used for vacuum measurement).

3. Open the vent valve, wait for the pressure to settle to zero, and screw in the main screw press. As you do this, you may see bubbles emerge in the medium reservoir which is a good indication that gas is being pushed out of the system.

4. Close the vent valve and repeat steps 2 and 3 one or two more times.

5. Close the vent valve and unscrew the main screw press half way out. Then open the vent valve to zero the measurement.

6. Now, you are ready to close the vent valve and generate pressure.

Vent

Main screw press

Stable Measurements

As pressures are generated to the desired test point it is common to initially observe a fairly rapid decrease in pressure.

Initially, you may conclude that this is a pressure leak but what you are likely observing is called the adiabatic effect. This effect is defined as a gain or loss of heat within a system and its environment. When a gas is compressed under adiabatic conditions, its pressure increases and its temperature rises without the gain or loss of any heat. This happens when the screw press of a pump compresses the fluid volume, thus resulting in an increase in pressure but also an increase in the temperature. As the increase in pressure stops the temperature generated from the screw press dissipates. If the volume is held constant and the temperature decreases so also will the pressure decrease. So this initial degrease of pressure is in fact a result of the temperature settling from the adiabatic heating effect generated from the screw press of the pump.

Other sources of instability that also impact the pressure measurement are instabilities in room temperature and changes in volume. Because temperature is a factor of pressure as the entire pressure system changes temperature due to the room temperature changing the true pressure value will also change. The same can also be said of the pressure volume.

With an increase or decrease of pressure volume the true pressure value will see a correlated change. Volume changes with pressure systems are usually not very noticeable except at high pressures. At high pressures, the materials where the pressurized volume is contained will slightly expand causing the volume to expand and the pressure will decrease.

This is particularly evident when using flexible hoses at high pressures.

Conclusion

So we can't change the laws of physics—so what can be done? As pressures are generated, time must be given to allow for the adiabatic effects to settle. In other words, you need to let the measurement stabilize for a few minutes. As you allow this stabilization period to happen, you'll find the measurement stability of the pump to be very reliable for your calibration applications. Room temperature will also have an impact on the measurement and it is best if calibrations are performed in a controlled, stable environment. Lastly, careful consideration of hoses, manifolds, and tubing will help produce stable results at high pressures. Using metal tubing as opposed to flexible hoses will yield higher stability as metal is less likely to allow for the volume to expand when under high pressure.

Look us up on www.additel.com or call today (1)714-998-6899

Additel 927

Hydraulic Pressure Test Pump

Generate 85% vacuum to 10,000 psi (700 bar) pressure

Portable, only 7 lb

Minimal maintenance

Increase and decrease pressure smoothly

Hand-tight quick connectors

OVERVIEW

The 927 Hydraulic Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 85% vacuum to 10,000 psi (700 bar). With the patented screw press technology, high pressures can be easily generated, as well as increased and decreased smoothly. With no check valve (non-returning valve), the 927 avoids the troublesome leakage issues that is usually experienced with most hand pumps and allows for minimal maintenance. Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 927 is an ideal comparison test pump for calibrating pressure measuring instruments such as test gauges, indicators or transducers in the field or laboratory.

FEATURES

Portable

Only 7 lb

Durable and Minimal Maintenance

Patented screw press technology, without nonreturning valve inside that is usually used on troublesome hand pumps.

Easy-to-use

The high pressure can be generated easily, as well as increased and decreased smoothly.

Extremely Low Leakage

Patented screw press technology, replaces troublesome check valves (non-returning valve) used in most hand pumps which practically eliminates leakage.

Hand-tight Quick Connectors

Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.

ORDERING INFORMATION

Model Number

ADT927 N

SPECIFICATIONS

Media: Oil or deionized water.

(Oil is default media liquid. Pump with water as media to be ordered specifically)

Reservoir capacity: 245 ml (15 in

Generated Pressure Range

3

)

85% vacuum to 10,000 psi (700 bar) positive pressure.

Material: Ram/adapters: SS

Body: SS, aluminum

Seals: Buna-N, PTFE, Copper Alloy

Connection

Hand-tight connectors for both test gauge and reference gauge.

1/4NPT female, 1/2NPT female, 1/4BSP female,

1/2BSP female, or M20X1.5 female

Dimensions: Height: 5.31'' (135 mm)

Base: 11.42'' (290 mm) x 7.80'' (198 mm).

Weight: 7 lb (3.2 kg).

Warranty: 1 year

Piston volume

Low pressure piston: 19 ml (1.2 in

3

)

High pressure piston: 0.9 ml (0.05 in

3

)

Model

Pressure port type:

N -

1/4

NPT female

N2 - 1/2NPT female

B - 1/4BSP female

B2 - 1/2BSP female

M - M20X1.5 female

Accessories included

Mineral oil,1 bottle (250 ml)*

O-ring: 20 pcs

Manual: 1 pc

* When water media is not requested

Optional Accessories

Model number

9201

ADT102

ADT103

ADT100-HTK

9904-927

ADT927-MK

Description

Oil, Diethylhexyl Sebacate, 1 liter (1 quart)

Adapters and fittings, 1/4NPT male to various male and female connection

(25 pcs). More information shown on page 61.

Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.

Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT

(1/8NPT, 1/2NPT, 1/4BSP,1/2BSP, or M20X1.5) female hand-tight quick connector. More information shown on page 63.

Carrying Case for one 927 pump and two 681 gauges or 672 calibrators

Maintenance kit for Additel 927 pump

Look us up on www.additel.com or call today (1)714-998-6899

51

52

Additel 928

Hydraulic Pressure Test Pump

Pressurize large-volume workload

Generate to 15,000 psi (1,000 bar) pressure

Portable only 8.6 lbs (3.9 kg)

Increase and decrease pressure smoothly

Hand-tight quick connectors

OVERVIEW

The Additel 928 Hydraulic Pressure Test Pump is a hand operated pressure pump designed to generate pressure to

15,000 psi (1,000 bar). This pump incorporates a dual-piston system which is ideal for filling large volume workload with the hand pump and providing smooth increase and decrease of pressure with the fine adjustment. The 928 Test

Pump incorporates an isolation valve which isolates the calibration volume from the check valve associated with the hand pump. Because the check valve can often be a source of leaks and maintenance, the isolation valve provides more stable measurements and reduces potential maintenance of the pump. Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.

The Additel 928 is an ideal comparison test pump for calibrating pressure measuring instruments such as test gauges, indicators or transducers in the field or laboratory.

FEATURES

Hand pump to fill large volume systems

Portable at 8.6 lbs (3.9 kg)

Durable and minimal maintenance

Isolation valve provides stable pressures while reducing maintenance on the hand pump check valve

Easy to use

15,000 psi (1,000 bar) can be generated easily with the dual-piston system

Hand-tight quick connectors

Allows easy connection and disconnection to the test pump without the need for PTFE tape or wrenches

SPECIFICATIONS

Media: Mineral oil or deionized water.

(Oil is default media liquid. Pump with water as media to be ordered specifically)

Generated Pressure Range

0 to 15,000 psi (1,000bar) gauge pressure

Material: Ram/adapters: SS

Body: SS, aluminum

Seals: Buna-N, PTFE, Copper Alloy

Connection

Hand-tight connectors for both test gauge and reference gauge.

1/4NPT female, 1/2NPT female, 1/4BSP female,

1/2BSP female, or M20X1.5 female

Dimensions: Height: 6.38'' (162 mm)

Base: 13.58'' (345 mm) x 8.46'' (215 mm)

Weight: 8.6 lb (3.9 kg)

Warranty: 1 year

Piston Volume: Fine adjust piston: 0.9ml (0.05 in

3

)

ORDERING INFORMATION

Model Number

Optional Accessories

ADT928 N

Model number

Model Pressure port type:

N -

1/4

NPT female

N2 - 1/2NPT female

B - 1/4BSP female

B2 - 1/2BSP female

M - M20X1.5 female

9202

ADT102

ADT103

ADT100-HTK

Accessories included

9202 Mineral oil,1 bottle (250 ml)*

O-ring: 20 pcs

Manual: 1 pc

* When water media is not requested

9904-928

ADT928-MK

ADT100-928-HK

Look us up on www.additel.com or call today (1)714-998-6899

Description

Oil, Mineral oil, 1 liter (1 quart)

Adapters and fittings, 1/4NPT male to various male and female connection

(25 pcs). More information shown on page 61.

Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.

Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT

(1/8NPT, 1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) female hand-tight quick connector. More information shown on page 63.

Carrying Case for one 928 pump and two pressure test gauges

Maintenance kit for Additel 928 pump

Hose Kit, External Reservoir Expansion Hose Kit for ADT928

Additel 936

Hydraulic High Pressure Calibration Pump

Generate 85% vacuum to 15,000 psi (1,000 bar) pressure

Minimal maintenance

Increase and decrease pressure smoothly

Three pressure ports

Hand-tight quick connectors

OVERVIEW

The 936 Hydraulic High Pressure Test Pump is a hand operated pressure pump designed to generate pressure from

85% vacuum to 15,000 psi (1,000 bar). With the patented screw press technology, high pressures can be easily generated, as well as increased and decreased smoothly. A specially designed shut-off valve makes the pressure as stable as possible during calibration. With no check valve (non-returning valve), the 936 avoids the troublesome leakage issues that is usually experienced with hand pumps and allows for minimal maintenance. Three hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 936 is an ideal comparison test pump for calibrating pressure measuring instruments such as test gauges, indicators or transducers in the laboratory.

FEATURES

High Pressure

Generates pressure up to 15,000 psi (1000 bar)

Durable and Minimal Maintenance

Patented screw press technology, without nonreturning valve inside that is usually used on troublesome hand pumps.

Easy-to-use

High pressures can be generated easily, as well as increased and decreased smoothly.

Extremely Low Leakage

Patented screw press technology replaces troublesome check valves (non-returning valve) in most hand pumps which practically eliminates leakage.

Hand-tight Quick Connectors

Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.

SPECIFICATIONS

Media: Oil

Reservoir capacity: 420 ml (25.6 in

Pressure Range

3

)

85% vacuum to 15,000 psi (1,000 bar) positive.

Material

Ram/adapters: SS

Body: SS/aluminum

Seals: Buna-N, PTFE, Copper Alloy, SS

Connection

Hand-tight connectors for both test gauge and reference gauge(s).

1/4NPT female, 1/2NPT female, 1/4BSP female,

1/2BSP female, or M20X1.5 female

Dimensions

Height: 9.1'' (230 mm)

Base: 20.5'' (520 mm) x 14.2'' (360 mm)

Weight: 35.2 lb (16 kg).

Warranty: 1 year

Piston volume

Low pressure piston: 30 ml (1.8 in

3

)

High pressure piston: 2.5 ml (0.15 in

3

)

ORDERING INFORMATION

Model Number

ADT936 N

Model

Pressure port type:

N -

1/4

NPT female

N2 - 1/2NPT female

B - 1/4BSP female

B2 - 1/2BSP female

M - M20X1.5 female

Accessories included

Mineral oil,1 bottle (250 ml)

O-ring: 20 pcs Manual: 1 pc

Optional Accessories

Model number

9201

ADT102

ADT103

9908

ADT936-MK

Description

Oil, Diethylhexyl Sebacate, 1 liter (1 quart)

Adapters and fittings, 1/4NPT male to various male and female connection

(25 pcs). More information shown on page 61.

Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.

Carrying case for 936, 937, 938 or 949.

Maintenance kit for Additel 936 pump

Look us up on www.additel.com or call today (1)714-998-6899

53

54

Additel 937

Hydraulic High Pressure Calibration Pump

Generate 85% vacuum to 15,000 psi (1,000 bar) pressure

Compatible to phosphoric acid ester fluid and Skydrol Oil

Increase and decrease pressure smoothly

Three pressure ports

Hand-tight quick connectors

OVERVIEW

The 937 Hydraulic High Pressure Calibration Pump is a hand operated pressure pump designed for calibrating pressure measuring instruments with phosphoric acid ester fluid and Skydrol oil in the range from 85% vacuum to 15,000 psi (1000 bar). With the patented screw press technology, high pressures can be easily generated, increased and decreased smoothly. A specially designed shut-off valve makes the pressure as stable as possible during calibration. With no check valve (non-returning valve), the 937 avoids the troublesome leakage issues that is usually experienced with hand pumps and allows for minimal maintenance. Three hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 937 is an ideal comparison test pump for calibrating pressure measuring instruments such as test gauges, indicators or transducers in the laboratory.

FEATURES

High Pressure

Generates pressure up to 15,000 psi (1,000 bar)

Durable and Minimal Maintenance

Patented screw press technology, with no check valve (non-returning valve) inside that is usually used on troublesome hand pumps causing leakage.

Easy-to-use

High pressures can be generated easily, as well as increased and decreased smoothly.

Hand-tight Quick Connectors

Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.

SPECIFICATIONS

Media: Compatible to phosphoric acid ester fluid and Skydrol Oil (should not be used for mineral oil)

Reservoir capacity: 420 ml (25.6 in

3

Pressure Range

)

85% vacuum to 15,000 psi (1,000 bar) positive.

Material: Ram/adapters: SS

Body: SS, aluminum

Seals: EPDM, PTFE, Copper Alloy

Connection

Hand-tight connectors for both test gauge and reference gauge(s).

1/4NPT female, 1/2NPT female, 1/4BSP female,

1/2BSP female, or M20X1.5 female

Dimensions

Height: 9.1'' (230 mm)

Base: 20.5'' (520 mm) x 14.2'' (360 mm)

Weight: 35.2 lb (16 kg).

Warranty: 1 year

Piston volume

Low pressure piston: 30 ml (1.8 in

3

)

High pressure piston: 2.5 ml (0.15 in

3

)

ORDERING INFORMATION

Model Number

ADT937 N

Model Pressure port type:

N -

1/4

NPT female

N2 - 1/2NPT female

B - 1/4BSP female

B2 - 1/2BSP female

M - M20X1.5 female

Accessories included

O-ring: 20 pcs Manual: 1 pc

Look us up on www.additel.com or call today (1)714-998-6899

Optional Accessories

Model number

ADT102

ADT103

9908

ADT937-MK

Description

Adapters and fittings, 1/4NPT male to various male and female connection

(25 pcs). More information shown on page 61.

Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.

Carrying case for 936, 937, 938 or 949.

Maintenance kit for Additel 937 pump

Additel 938

Hydraulic High Pressure Calibration Pump

Generate 85% vacuum to 15,000 psi (1,000 bar) pressure

Oil-free pressure instruments

Minimal maintenance

Easy-to-use

Three pressure ports

Hand-tight quick connectors

OVERVIEW

The 938 Hydraulic High Pressure Test Pump is specially designed for calibrating oil-free pressure measuring instruments in the range of 85% vacuum to 15,000 psi (1,000 bar). All parts used in the pump have been carefully cleaned to remove oil. The pump uses water as the media. With the patented screw press technology, high pressures can be easily generated, as well as increased and decreased smoothly. A specially designed shut-off valve makes the pressure as stable as possible during calibration. With no check valve (non-returning valve), the 938 avoids the troublesome leakage issues that is usually experienced with hand pumps and allows for minimal maintenance. Three hand-tight connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 938 is an ideal comparison test pump for calibrating oil-free pressure measuring instruments such as test gauges, indicators or transducers in the laboratory.

FEATURES

High Pressure

Generates pressure up to 15,000 psi (1,000 bar)

Durable and Minimal Maintenance

Patented screw press technology, without nonreturning valve inside that is usually used on troublesome hand pumps.

Easy-to-use

With the patented screw press technology, high pressures can be generated easily, as well as increased and decreased smoothly

Extremely Low Leakage

Patented screw press technology replaces troublesome check valves (non-returning valve) in most hand pumps which practically eliminates leakage.

Hand-tight Quick Connectors

Allows easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches.

ORDERING INFORMATION

Model Number

SPECIFICATIONS

Media: Deionized water

Reservoir capacity: 420 ml (25.6 in

Pressure Range

3

)

85% vacuum to 15,000 psi (1,000 bar) positive pressure.

Material

Ram/adapters: SS

Body: SS, aluminum

Seals: Buna-N, PTFE, Copper Alloy

Reservoir capacity: 420 ml (25.6 in

3

)

Connection

Hand-tight connectors for both test gauge and reference gauge.

1/4NPT female, 1/2NPT female, 1/4BSP female,

1/2BSP female, or M20X1.5 female

Dimensions

Height: 9.1'' (230 mm)

Base: 20.5'' (520 mm) x 14.2'' (360 mm)

Weight: 35.2 lb (16 kg).

Warranty: 1 year

Piston volume

Low pressure piston: 30 ml (1.8 in

3

)

High pressure piston: 2.5 ml (0.15 in

3

)

ADT938 N

Optional Accessories

Model Pressure port type:

N -

1/4

NPT female

N2 - 1/2NPT female

B - 1/4BSP female

B2 - 1/2BSP female

M - M20X1.5 female

Accessories included

O-ring: 20 pcs

Manual: 1 pc

Model number

ADT102

ADT103

9908

ADT938-MK

Description

Adapters and fittings, 1/4NPT male to various male and female connection

(25 pcs). More information shown on page 61.

Adapters and fittings, 1/4NPT (1/2NPT, 1/4BSP, 1/2BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.

Carrying case for 936, 937, 938 or 949.

Maintenance kit for Additel 938 pump

Look us up on www.additel.com or call today (1)714-998-6899

55

56

Additel 946

Hydraulic High Pressure Calibration Pump

Pressureize large-volume worklaoad

Generate pressure to 15,000 psi (1,000 bar)

Increase and decrease pressure smoothly

Three pressure ports

Hand-tight quick connectors

OVERVIEW

The new Additel 946 Hydraulic Pressure Test Pump is a benchtop pressure pump designed to generate pressure to

15,000 psi (1,000 bar). This pump incorporates a dual-piston system which is ideal for filling large volume workload with the hand pump and providing smooth increase and decrease of pressure with the high pressure, fine adjust screw press. The 946 test pump incorporates an isolation valve which isolates the calibration volume from the check valve associated with the hand pump. Because the check valve can often be a source of leaks and maintenance, the isolation valve provides more stable measurements and reduces potential maintenance of the pump. Three hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The Additel 946 is an ideal comparison test pump for calibrating pressure measuring instruments such as test gauges, indicators or transducers.

FEATURES

Hand pump to fill large volume systems

Durable and Minimal Maintenance

Isolation valve provides stable pressures while reducing maintenance on the hand pump check valve.

Easy-to-use

15,000 psi (1,000 bar) can be generated easily with the dual-piston system.

Three hand-tight quick connectors

Allows easy connection and disconnection to the test pump without the need for PTFE tape or wrenches.

SPECIFICATIONS

Media: Mineral oil or deionized water. (Oil is default media liquid. Pump with water as media to be ordered specifically)

Generated Pressure Range

0 to 15,000 psi (1,000bar) gauge pressure

Material

Ram/adapters: SS

Body: SS, aluminum, Copper

Seals: Buna-N

Connection

Hand-tight connectors for both test gauge and reference gauge

Dimensions: Height: 6.9'' (175 mm)

Base: 17.9'' (455 mm) x 15.0'' (380 mm)

Weight: 28.7 lb (13 kg).

Warranty: 1 year

Piston volume

Fine adjust piston: 1.5ml (0.09 in

3

)

ORDERING INFORMATION

Model Number

ADT946 N

Optional Accessories

Model number

9202

Model

Pressure port type:

N -

1/4

NPT female

N2 - 1/2NPT female

B - 1/4BSP female

B2 - 1/2BSP female

M - M20X1.5 female

ADT102

ADT103

ADT-HTK

Accessories included

Mineral oil,1 bottle (250 ml)*

O-ring: 20 pcs

ADT946-MK

ADT100-946-HK

Manual: 1 pc

*When water media is not requested

Look us up on www.additel.com or call today (1)714-998-6899

Description

Oil, Mineral oil, 1 liter (1 quart)

Adapters and fittings, 1/4HP male to various male and female connectors

(25 pcs). More information shown on page 61.

Adapters and fittings, 1/4NPT (1/4BSP, or M20X1.5) male to various female hand-tight quick connectors (10 pcs). More information shown on page 62.

Hose test kit, 5 feet flexible hose, 15,000 psi, 1/4NPT male to 1/4NPT

(1/8NPT, 1/2NPT, 1/4BSP, or M20X1.5) female hand-tight quick connector. More information shown on page 63.

Maintenance kit for Additel 946 pump

Hose Kit, External Reservoir Expansion Hose Kit for ADT946

Additel 949

Hydraulic Ultra-high Pressure Test Pump

Generate 85% vacuum to 40,000 psi (2,800 bar) pressure

Minimal maintenance

Easy-to-use

Three pressure ports

OVERVIEW

The 949 Hydraulic Ultra-high Pressure Test Pump is a hand operated pressure pump designed to generate pressure up to 40,000 psi (2800 bar). With the patented screw press technology, high pressures can be easily generated, increased and decreased smoothly. A specially designed shut-off valve makes the pressure as stable as possible during calibration. With no non-returning valve, the 949 avoids the troublesome leakage issues that is usually experienced with hand pumps and allows for minimal maintenance. The 949 is an ideal comparison test pump for calibrating ultra-high pressure measuring instruments such as test gauges, indicators or transducers in the laboratory.

FEATURES

Generate Ultra-high Pressure

Generate pressure up to 40,000 psi (2,800 bar)

Durable and Minimal Maintenance

Patented screw press technology, without nonreturning valve inside that is usually used on troublesome hand pumps.

Easy-to-use

With the patented screw press technology, high pressures can be generated easily, as well as increased and decreased smoothly.

Extremely Low Leakage

Patented screw press technology replaces troublesome, check valves (non-returning valve) found in most hand pumps which practically eliminates leakage.

ORDERING INFORMATION

Model Number

ADT949

Model

AF

Pressure port type:

AF-Autoclave F-250-C female

B2-1/2BSP female

X-Customize

SPECIFICATIONS

Media: Oil

Pressure Range

85% vacuum to 40,000psi (2,800bar) positive pressure.

Material

Ram/adapters: SS

Body: SS, aluminum

Seals: Buna-N, PTFE, Copper Alloy

Reservoir capacity: 420 ml (25.6 in

3

)

Connection

Test Gauge Connection: Positional Autoclave

F-250-C, 9/16" - 18 UNF female

Reference Gauge Connection: Positional Autoclave

F-250-C, 9/16" - 18 UNF female

1/2BSP female and M20X1.5 female connections are available upon request.

Dimensions: Height: 9.1'' (230 mm)

Base: 20.5'' (520 mm) x 14.2'' (360 mm)

Weight: 35.2 lb (16 kg).

Warranty: 1 year

Piston volume

Low pressure piston: 30 ml (1.8 in

3

)

High pressure piston: 2.5 ml (0.15 in

3

)

Accessories included

Diethylhexyl Sebacate oil: 1 bottle (250 ml)

Manual: 1 pc

Optional Accessories

Model number

9201

ADT104

9908

ADT949-MK

Description

Oil, Diethylhexyl Sebacate, 1 liter (1 quart)

Adapters and fittings, 1/4HP male to various male and female connectors

(17 pcs). More information shown on page 63.

Carrying case for 936, 937, 938 or 949.

Maintenance kit for Additel 949 pump

Look us up on www.additel.com or call today (1)714-998-6899

57

Additel 959

Hydraulic Ultra-high Pressure Test Pump

Pressurize large-volume workload

Generate pressure to 40,000 psi (2,800 bar)

Increase and decrease pressure smoothly

Three pressure ports

58

OVERVIEW

The new Additel 959 Hydraulic Pressure Test Pump is a benchtop pressure pump designed to generate pressure to

40,000 psi (2,800 bar). This pump incorporates a dual-piston system which is ideal for filling large volume workload with the hand pump and providing smooth increase and decrease of pressure with the high pressure, fine adjust screw press. The 959 test pump incorporates an isolation valve which isolates the calibration volume from the check valve associated with the hand pump. Because the check valve can often be a source of leaks and maintenance, the isolation valve provides more stable measurements and reduces potential maintenance of the pump. The Additel 946 is an ideal comparison test pump for calibrating pressure measuring instruments such as test gauges, indicators or transducers.

FEATURES

Generate Ultra-high Pressure

Generate pressure up to 40,000 psi (2,800 bar)

Hand pump to fill large volume systems

Durable and Minimal Maintenance

Isolation valve provides stable pressures while reducing maintenance on the hand pump check valve

Easy-to-use

40,000 psi (2,800 bar) can be generated easily with the dual-piston system

SPECIFICATIONS

Media: Oil

Pressure Range

0 to 40,000psi (2,800bar) gauge pressure.

Material

Ram/adapters: SS

Body: SS, aluminum, Copper

Seals: Buna-N, PTFE, Copper Alloy, Aluminum Alloy

Reservoir capacity: 420 ml (25.6 in

3

)

Connection

Test Gauge Connection: Autoclave F-250-C, 9/16" -

18 UNF female

Reference Gauge Connection: Autoclave F-250-C,

9/16" - 18 UNF female

1/2BSP female and M20X1.5 female connections are available upon request

Dimensions: Height: 6.9'' (175 mm)

Base: 17.9'' (455 mm) x 15.0'' (380 mm)

Weight: 28.7 lb (13 kg).

Warranty: 1 year

Piston volume

Fine adjust piston: 1.5 ml (0.09 in

3

)

ORDERING INFORMATION

Model Number

ADT959 AF

Model

Pressure port type:

AF-Autoclave F-250-C female

B2-1/2BSP female

X-Customize

Accessories included

Diethylhexyl Sebacate oil: 1 bottle (250 ml)

Manual: 1 pc

Optional Accessories

Model number

9201

ADT104

ADT959-MK

ADT100-959-HK

Description

Oil, Diethylhexyl Sebacate, 1 liter (1 quart)

Adapters and fittings, 1/4HP male to various male and female connectors

(17 pcs). More information shown on page 63.

Maintenance kit for Additel 959 pump

Hose Kit, External Reservoir Expansion Hose Kit for ADT959

Look us up on www.additel.com or call today (1)714-998-6899

Pressure Manifolds

Additel 12X Series

The 12X series pressure manifolds are designed for expanding pressure test ports during pressure calibration. The

Additel 121 pressure manifold is used for pneumatic pressure calibration up to 3,000 psi (200bar), while the Additel 123 manifolds is compatible to hydraulic pressure applications up to 15,000 psi (1,000 bar). A filter is built-in with the 121 pneumatic pressure manifold to prevent contamination introduced by devices under test. There are four hand-tight quick connectors pre-installed on each manifold. Additel 12X series pressure manifolds allow you to connect without the use of wrenches or Teflon tape which increases your productivity when using calibration pumps, pressure controllers, dead weight testers, or piston gauges.

121 series Pressure Manifolds

Pneumatic, -15 psi to 3,000 psi (-1 to 200 bar)

Model Description

ADT121-N 1/4NPT male hose to four 1/4NPT female hand-tight quick connectors

ADT121-N2 1/2NPT male hose to four 1/2NPT female hand-tight quick connectors

ADT121-M M20×1.5 male hose to four M20×1.5 female hand-tight quick connectors

ADT121-B 1/4BSP male hose to four 1/4BSP female hand-tight quick connectors

ADT121-B2 1/2BSP male hose to four 1/2BSP female hand-tight quick connectors

123 series Pressure Manifolds

Hydraulic, -15 to 15,000 psi (-1 to 1,000 bar)

Model Description

ADT123-N 1/4NPT male hose to four 1/4NPT female hand-tight quick connectors

ADT123-N2 1/2NPT male hose to four 1/2NPT female hand-tight quick connectors

ADT123-M M20×1.5 male hose to four M20×1.5 female hand-tight quick connectors

ADT123-B 1/4BSP male hose to four 1/4BSP female hand-tight quick connectors

ADT123-B2 1/2BSP male hose to four 1/2BSP female hand-tight quick connectors

127 series Pressure Manifolds

Pneumatic, -15 to 3,500 psi (-1 to 250 bar)

Model Description

ADT127-N 1/4NPT male hose to three 1/4NPT female hand-tight quick connectors

ADT127-N2 1/2NPT male hose to three 1/2NPT female hand-tight quick connectors

ADT127-M M20×1.5 male hose to three M20×1.5 female hand-tight quick connectors

ADT127-B 1/4BSP male hose to three 1/4BSP female hand-tight quick connectors

ADT127-B2 1/2BSP male hose to three 1/2BSP female hand-tight quick connectors

Note: A test hose is included with every Additel 12X pressure manifold.

Look us up on www.additel.com or call today (1)714-998-6899

59

Filters

Additel 100 Series Filters

ADT100-FLT-600

600 psi (40 bar) Pneumatic Filter Specifications

Pressure range

-15 to 600 psi (-1.0 to 40 bar)

Filtering resolution

Operation temperature

Safety pressure

0.04 mm

-10°C to 50°C

Size

<720 psi (50 bar)

1.18 dia x 5 in (30 dia x 127 mm)

(size will vary based on adapters)

Outlet/Inlet port

Storage temperature

See ordering information

-20°C to 70°C

Material

304 SS

ADT100-FLT-10K

10,000 psi (700 bar) Hydraulic Filter Specifications

Pressure range

Filtering resolution

-15 to 10,00 psi (-1.0 to 700 bar)

0.07 mm

Operation temperature

-10°C to 50°C

Safety pressure

<12,000 psi (827 bar)

Size

Outlet/Inlet port

Storage temperature

Material

0.87 x 0.98 x 4 in (22 x 25 x 100 mm)

(size will vary based on adapters)

Comes with removable male and removable female adapter

-20°C to 70°C

304 SS

ORDERING INFORMATION

ADT100 600 N

Range:

600 -600 psi (40 bar)

10K-10,000 psi (700 bar)

Port type:

N-1/4NPT male and 1/4NPT female

N2-1/2NPT male and 1/2NPT female

B-1/4BSP male and 1/4BSP female

B2-1/2BSP male and 1/2BSP female

M-M20x1.5 male and M20x1.5 female

60

Look us up on www.additel.com or call today (1)714-998-6899

ADT100-FLT-10K

Inlet

Seals

Window

Seals

Drain valve

Filter

Seals

Outlet

ADT100-FLT-600

Pressure Hoses, Adapters and Fittings

Additel 102

(Designed for all pumps except Additel 949 pump)

Additel 102

ADT102

1/4NPT male to various connectors as follows (25 pcs, case included)

*1/2NPT male, 1/4BSP male, 1/2BSP male, M20X1.5 male are available per request.

Model

ADT100-NPTM4-BSPM8

ADT100-NPTM4-BSPM4

ADT100-NPTM4-BSPM2

ADT100-NPTM4-BSPM3

ADT100-NPTM4-M10M

ADT100-NPTM4-M14M

ADT100-NPTM4-M20M

ADT100-NPTM4-NPTM8

ADT100-NPTM4-NPTM4

ADT100-NPTM4-NPTM2

ADT100-NPTM4-NPTM3

ADT100-NPTM4-BSPF8

ADT100-NPTM4-BSPF4

ADT100-NPTM4-BSPF2

ADT100-NPTM4-BSPF3

ADT100-NPTM4-M10F

ADT100-NPTM4-M14F

ADT100-NPTM4-M20F

ADT100-NPTM4-NPTF8

ADT100-NPTM4-NPTF4

ADT100-NPTM4-NPTF2

ADT100-NPTM4-NPTF3

Description

Adapter, 1/4NPT male to 1/8BSP male

Adapter, 1/4NPT male to 1/4BSP male

Adapter, 1/4NPT male to 1/2BSP male

Adapter, 1/4NPT male to 3/8BSP male

Adapter, 1/4NPT male to M10X1.0 male

Adapter, 1/4NPT male to M14X1.5 male

Adapter, 1/4NPT male to M20X1.5 male

Adapter, 1/4NPT male to 1/8NPT male

Adapter, 1/4NPT male to 1/4NPT male

Adapter, 1/4NPT male to 1/2NPT male

Adapter, 1/4NPT male to 3/8NPT male

Adapter, 1/4NPT male to 1/8BSP female

Adapter, 1/4NPT male to 1/4BSP female

Adapter, 1/4NPT male to 1/2BSP female

Adapter, 1/4NPT male to 3/8BSP female

Adapter, 1/4NPT male to M10X1.0 female

Adapter, 1/4NPT male to M14X1.5 female

Adapter, 1/4NPT male to M20X1.5 female

Adapter, 1/4NPT male to 1/8NPT female

Adapter, 1/4NPT male to 1/4NPT female

Adapter, 1/4NPT male to 1/2NPT female

Adapter, 1/4NPT male to 3/8NPT female

Max Pressure

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

ADT100-HTK-NPTM4-NPTF4Q

Hose Test Kit, 5 feet flexible hose, 15,000 psi,

1/4NPT male to 1/4NPT female hand tight quick connector

15,000 psi

Picture

ADT100-NPTM4-NPTF4RQ

Adapter, 1/4NPT male to right angle 1/4NPT female hand-tight quick connector

15,000 psi

ADT100-NPTM4-BARB Adapter, 1/4NPT male to hose barb 150 psi

Don't need the entire kit? Order individual adapters with the above part numbers.

Look us up on www.additel.com or call today (1)714-998-6899

61

62

Pressure Hoses, Adapters and Fittings

Additel 103 Series

(Designed for all pumps except Additel 949 pump)

ADT103-NPT (Hand-tight quick connectors)

1/4NPT male to various hand-tight quick connectors (10pcs, case included)

Additel 103-NPT

Model Description

ADT100-NPTM4-NPTF8Q Adapters, 1/4NPT male to 1/8NPT female

ADT100-NPTM4-NPTF4Q Adapters, 1/4NPT male to 1/4NPT female

ADT100-NPTM4-NPTF2Q Adapters, 1/4NPT male to 1/2NPT female

ADT100-NPTM4-BSPF8Q Adapters, 1/4NPT male to 1/8BSP female

ADT100-NPTM4-BSPF4Q Adapters, 1/4NPT male to 1/4BSP female

ADT100-NPTM4-BSPF3Q Adapters, 1/4NPT male to 3/8BSP female

ADT100-NPTM4-BSPF2Q Adapters, 1/4NPT male to 1/2BSP female

ADT100-NPTM4-M10FQ Adapters, 1/4NPT male to M10×1.0 female

ADT100-NPTM4-M14FQ

ADT100-NPTM4-M20FQ

Adapters, 1/4NPT male to M14×1.5 female

Adapters, 1/4NPT male to M20×1.5 female

Max Pressure

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

Picture

ADT103-BSP (Hand-tight quick connectors)

1/4BSP male to various hand-tight quick connectors (10 pcs, case included)

Additel 103-BSP

Model Description

ADT100-BSPM4-NPTF8Q Adapter, 1/4BSP male to 1/8NPT female

ADT100-BSPM4-NPTF4Q Adapter, 1/4BSP male to 1/4NPT female

ADT100-BSPM4-NPTF2Q Adapter, 1/4BSP male to 1/2NPT female

ADT100-BSPM4-BSPF8Q Adapters, 1/4BSP male to 1/8BSP female

ADT100-BSPM4-BSPF4Q Adapters, 1/4BSP male to 1/4BSP female

ADT100-BSPM4-BSPF3Q Adapters, 1/4BSP male to 3/8BSP female

ADT100-BSPM4-BSPF2Q Adapters, 1/4BSP male to 1/2BSP female

ADT100-BSPM4-M10FQ

ADT100-BSPM4-M14FQ

ADT100-BSPM4-M20FQ

Adapters, 1/4BSP male to M10×1.0 female

Adapters, 1/4BSP male to M14×1.5 female

Adapters, 1/4BSP male to M20×1.5 female

Max Pressure

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

15,000 psi

Picture

ADT103-M20 (Hand-tight quick connectors)

M20

×

1.5 Male to various hand-tight quick connectors (10pcs, case included)

Additel 103-M20

Model

ADT100-M20M-NPTF8Q

ADT100-M20M-NPTF4Q

ADT100-M20M-NPTF2Q

ADT100-M20M-BSPF8Q

ADT100-M20M-BSPF4Q

ADT100-M20M-BSPF3Q

ADT100-M20M-BSPF2Q

ADT100-M20M-M10FQ

ADT100-M20M-M14FQ

ADT100-M20M-M20FQ

Description Max Pressure

Adapters, M20×1.5 Male to 1/8NPT female

Adapters, M20×1.5 Male to 1/4NPT female

Adapters, M20×1.5 Male to 1/2NPT female

Adapters, M20×1.5 Male to 1/8BSP female

15,000 psi

15,000 psi

15,000 psi

15,000 psi

Adapters, M20×1.5 Male to 1/4BSP female

Adapters, M20×1.5 Male to 3/8BSP female

15,000 psi

15,000 psi

Adapters, M20×1.5 Male to 1/2BSP female 15,000 psi

Adapters, M20×1.5 Male to M10×1.0 female 15,000 psi

Adapters, M20×1.5 Male to M14×1.5 female 15,000 psi

Adapters, M20×1.5 Male to M20×1.5 female 15,000 psi

Picture

Don't need the entire kit? Order individual adapters with the above part numbers.

Look us up on www.additel.com or call today (1)714-998-6899

Pressure Hoses, Adapters and Fittings

Additel 104 Hose Test Kits

ADT104-HP

1/4HP male (Autoclave M-250-C) to various connectors as follows (17pcs, case included);

(Designed for Additel 949 pump)

Model Description Max Pressure Picture

ADT100-HPM-M14F

ADT100-HPM-M20F

ADT100-HPM-BSPF4

ADT100-HPM-BSPF3

ADT100-HPM-BSPF2

ADT100-HPM-NPTF4

ADT100-HPM-NPTF2

ADT100-HPM-M14M

ADT100-HPM-M20M

ADT100-HPM-BSPM4

ADT100-HPM-BSPM3

ADT100-HPM-BSPM2

ADT100-HPM-NPTM4

ADT100-HPM-NPTM2

ADT100-HPM-HPM4

Adapter, 1/4HP male to M14X1.5 female

Adapter, 1/4HP male to M20X1.5 female

Adapter, 1/4HP male to 1/4BSP female

Adapter, 1/4HP male to 3/8BSP female

Adapter, 1/4HP male to 1/2BSP female

Adapter, 1/4HP male to 1/4NPT female

Adapter, 1/4HP male to 1/2NPT female

Adapter, 1/4HP male to M14X1.5 male

Adapter, 1/4HP male to M20X1.5 male

Adapter, 1/4HP male to 1/4BSP male

Adapter, 1/4HP male to 3/8BSP male

Adapter, 1/4HP male to 1/2BSP male

Adapter, 1/4HP male to 1/4NPT male

Adapter, 1/4HP male to 1/2NPT male

Adapter, 1/4HP male to 1/4HP male

40,000 psi

40,000 psi

40,000 psi

40,000 psi

40,000 psi

15,000 psi

15,000 psi

40,000 psi

40,000 psi

40,000 psi

40,000 psi

40,000 psi

15,000 psi

15,000 psi

40,000 psi

Additel 104

High Pressure Hose Test Kits

The Additel 100 series High Pressure Hose Test Kits are designed to extend your pressure calibrations to a convenient location to adapt from one pressure connection to another. Each test kit has 5 feet of flexible hose rated to 15,000 psi

(1,000 bar) which connects a male NPT, BSP, or Metric connector to a variety of female quick connectors. Additel's specially designed quick connectors allow for hand-tight connection without the need for wrenches or Teflon tape. The

Additel 100 series Hose Test Kits are a great accessory to any pressure pump or controller.

SPECIFICATIONS

Max pressure: 15,000 psi (1,000 bar)

Hose length: 5 ft (1.5 m)

Note: Custom lengths available by request.

ORDERING INFORMATION

Model Number

ADT100

HTK

NPTM4 NPTF4Q

Pressure port type:

NPTM4-1/4NPT male

NPTM2-1/2NPT male

BSPM4-1/4BSP male

BSPM2-1/2BSP male

M20M-M20x1.5 male

Pressure port type:

NPTF2Q-1/2NPT female quick connect

NPTF3Q-3/8NPT female quick connect

NPTF4Q-1/4NPT female quick connect

NPTF8Q-1/8NPT female quick connect

BSPF2Q-1/2BSP female quick connect

BSPF3Q-3/8BSP female quick connect

BSPF4Q-1/4BSP female quick connect

BSPF8Q-1/8BSP female quick connect

M20FQ-M20x1.5 female quick connect

Don't need the entire kit? Order individual adapters with the above part numbers.

Look us up on www.additel.com or call today (1)714-998-6899

63

Low Pressure Hose Test Kits

The Additel 100 series Low Pressure Hose Test Kits are designed to extend your pressure calibrations to a convenient location to adapt from one pressure connection to another. Each test kit has 5 feet of flexible hose rated to 1,000 psi (70 bar) which connects a male NPT, BSP, or Metric connector to a variety of female quick connectors. Additel's specially designed quick connectors allow for hand-tight connection without the need for wrenches or Teflon tape. The Additel

100 series Hose Test Kits are a great accessory to any pressure pump or controller.

SPECIFICATIONS

Max pressure: 1,000 psi (70 bar)

Hose length: 5 ft (1.5 m)

Connection: Each hose test kit is fitted with a female quick connect adapter on one end and a corresponding male adapter on the other.

(e.g. ADT100-HTK-1K-N has a 1/4 NPT female quick connect on one end and a 1/4 NPT male adapter on the other).

Note: Custom lengths available by request.

ORDERING INFORMATION

Model Number

ADT100

HTK

1K

Pressure port type:

N-1/4NPT male

N2-1/2NPT male

B-1/4BSP male

B2-1/2BSP male

M-M20x1.5 male

N

Don't need the entire kit? Order individual adapters with the above part numbers.

Software

Additel 95XX Series

ACal

ACal is a pressure calibration system running under network environment, it has a simple and friendly interface and supports the cooperation of Multiuser. This software assist with automated and semi automated calibrationsas well as a powerful instrument management features.

Main features

Supports multi-users and network environments

Calibration and asset management

Simple user interface

Scanning and printing of QR codes

User definable permissions and access levels

Preset test configurations

Can calibrate variety pressure instruments

Can calibrate several instruments at a time

Calibration planning and scheduling

Certificate management and creation

Certificate customization

64

Look us up on www.additel.com or call today (1)714-998-6899

9506 Additel/PCal

The Additel PCal Pressure Calibration software is used with the 681 pressure gauges, 672 calibrators, and any of the 9XX pumps.

Semi-automated calibration of pressure gauges, transmitters, transducers and other pressure devices can be performed.

Software can be used to manage reference standard instruments and devices under test, as well as generate and customize a calibration certificate.

9502 Additel/Log II & 9503 Additel/Log II Wireless

Additel/Log II is a real-time data logging and graphical software for the ADT681 series digital pressure gauges and the ADT672 series digital pressure calibrators.

Data can be recorded in real-time and for the ADT681 data logging version, recorded results can be uploaded.

After results are stored, they can be exported to a customizable report showing pressure and ambient temperature. Each real-time test can be tagged with a unique record name.

Additel/Log II Wireless is a real-time data logging and graphical software for the ADT680W series wireless digital pressure gauge. Data can be recorded in real-time and historical data in the gauge can be uploaded.

After results are stored, they can be exported to a customizable report showing pressure and ambient temperature. Each real-time test can be tagged with a unique record name.

The software lets you acquire data to your PC. You can choose to display the real-time or historical pressure measurement data in a table or in a graph.

9510 Additel/Cal

Task management software for the 22XA series multifunction process calibrators and the 761 series automated pressure calibrators.

Additel/Cal was designed specifically for task management of temperature and pressure calibration.

The main features include establishing a database of all reference and test instruments, maintaining a customer database, creating, uploading and downloading calibration tasks, generating a calibration report, and customizing the calibration certificate.

9500 Additel/Land & Additel/Land Wireless

With Additel/Land software, you may download test results stored in the internal memory of Additel calibrators to a PC, and export the results to an excel file. It is a free software package and can be downloaded at www.additel.com.

Look us up on www.additel.com or call today (1)714-998-6899

65

Precision Under Pressure

Phone: 714-998-6899 Fax: 714-998-6999 Email: [email protected]

Corporate Headquarters

2900 Saturn Street #B

Brea, CA 92821, USA

European Office

Holkebjerhvej 79

5250 Odense, Denmark

Salt Lake City Office

1364 West State Rd Suite 101

Pleasant Grove, UT, 84062, USA

Asia Office

5th Building, No. 3 Fengxiu Middle Road,

Haidian, Beijing 100094, China

advertisement