ADT
T 780 Series
s Pres
ssure Contro
C
oller













Pre
essure ranges from
m vacuum
m to 200 bar (3,00
00 psi)
Rem
movable interchan
ngeable iintelligentt sensors
s
Pre
ecision acccuracy models
m
to
o 0.01% of
o reading
g
Sta
andalone solution to 70 ba
ar (1,000
0 psi), no
o gas botttle required when
use
ed with th
he electric
c pump
Sta
andard model accu
uracy of 0
0.02% of full scale
e
Extternal pre
essure mo
odules to
o 200 bar (3,000 psi)
p
WiF
Fi enable
ed commu
unicationss
Fully temperature co
ompensatted accurracy from 0°C to 5
50°C
ART comm
municatio
on and Prrofibus PA
A
HA
Larrge 7” collor touch screen d
display
Con
ntrol stab
bility of 0.003% FS
S
Buiilt-in baro
ometer
Eassy-to-use
e icon bas
sed user interface
e
Overvie
O
ew
For
F years, we have provided
p
the
e most dura
able, accurrate, quality
y pressure calibration products fo
or
field
f
applica
ations. The
e Additel 78
80 series co
ontroller inc
corporates the same ddurability, accuracy
a
an
nd
quality
q
into a new bencch top controller packe
ed with feattures and fu
unctionality that is remarkably eassy
to
t use. The
e Additel 780
7
series offers
o
two base range
es: to 70 bar
b and 2000 bar. The base rang
ge
establishes
e
the maxim
mum controlling range of the con
ntroller. Eac
ch configuraation includ
des a control
sensor
s
whicch is preselected to the
e sensor ran
nge best su
uited for you
ur applicatioon. Externall and internal
sensors
s
can
n be used which
w
allows
s an expand
ded range and
a accurac
cy capabilityy in the futu
ure.
There
T
are also two controllers
c
types that can be se
elected: Th
he Additel 780S us the
t
standarrd
controller
c
o
option witho
out any measurement capability. The Addite
el 780 has expanded functionalitty
including
i
electrical mea
asurement and HART and Profibu
us PA comm
munication.
Modula
M
ar design
Each
E
unit ccomes with one intelligent pressurre module
configured
c
any range offerings provided.
to the ma
Standard
S
a
accuracy se
ensors (AD
DT160A-CP
PXXX) are
silicone
s
pre
essure senssors with a 1 year acccuracy of
0.02%
0
FS. The precission quartz sensors im
mprove the
1 year acccuracy specification to
o 0.01% o
of reading
100% to 30% off range. Ea
from
f
ach sensor has been
specially
s
ag
ged, tested and screen
ned before a
assembly.
After
A
assem
mbly each sensor is temperature
t
e compensated over the range of 0 °C to 50 °C. Th
he
Additel
A
780
0 series can
n be equipped with o ne internal pressure sensor
s
andd one external pressurre
sensor.
s
The modular design of this unit p
provides forr interchang
geability off both the internal an
nd
external
e
se
ensors with
h other inte
elligent presssure modules. In ad
ddition to tthe Intelliga
ant Pressurre
Modules.
M
In
I addition to the Inte
elligent Pre
essure Mod
dules, the Additel
A
780
0 series haas a built in
n barometrric
sensor.
s
Thiss allows forr switching between
b
ga
auge pressu
ures to abso
olute pressuures.
Standal
S
lone solution
Typical
T
presssure contro
oller will req
quire a nitro
ogen bottle for
f the gas
supply
s
whicch makes it difficult to move
m
the co
ontroller aro
ound
without
w
havve to move or
o connect another
a
botttle.
Process
P
s functiionality (excl. ADTT780S verrsions)
The
T 780 series pressure controlle
er is conside
ered to hand
dle a very wide
w
range
of
o applications which may norm
mally require
e a pressure calibrato
or. Built-in
capability
c
in
ncludes currrent and vo
oltage meassurement ca
apability, 24
4 volt loop
power,
p
HAR
RT™ and Profibus PA communica
ation, switch
h measurem
ment capabiility and mu
uch more.
Measur
M
rement specific
s
cations
Specificatio
S
on
Pressure
P
range
Control sta
ability
Precision
(includes 1 year stabiliity)
Media
Over-range
e indication
Resolution
Pressure ty
ype
Warm up ty
ype
Typical pre
essure settling time
(within 0.00
03% FS)
Measureme
ent units
Minimum c
control press
sure[3]
ADT780-1K
ADT780-3K
K
-0
0.95 bis 70 ba
ar
-0..95 bis 200 bar
b [1]
(Vaku
uum bis 1,000 psi)
(Vakkuum bis 3,00
00 psi)
0.003
3% FS (stab
bility based on % FS of coontrol sensorr range
See pressure range tab le
Clea
an gas
103
3% to 120% (based
(
on seensor)
4, 5,, 6 or 7 digits
s (user selecttable[2]
Gauge, absolute
15 minutes
m
20 secon
nds (10% FS pressure change assum
ming 50ccm te
est volume)
Pa, hP
Pa, kPa, MPa
a, bar, mbar, psi, mmHg@
@0°C,cmHg
g@0°C,
mHg@0
0°C, inHg@0°C,inH2O@4
4°C, mmH2O
O@4°C, cmH2O@4°C,
mH2O@4
4°C, mmH2O@20°C,
O
cmH2O@20°C,, mH2O@20°°C, kg/m2,
2
kg/cm , mto
orr, torr, atm, lb/ft2, tsi, useer selectable
e
0.007 mbar (0.000
01 psi)
0.077 mbar (0.001 psi)
[1]
[ HP gas supp
ply requited to re
each 200 bar (3
3,000 psi)
[2]
[ 7 digit resolu
ution for precisio
on mode only
[3]
[ Dependent o
on pressure mod
dule
Barometric measurement specifications
Sensor
Standard Sensors
Precision Sensors
Gauge
n/a
3 Pa
Absolute
40 Pa
n/a
Barometer range (60-110)kPa, the accuracy is 40 Pa (11 Pa is optional)
[1] 40 PA uncertainty (k=2)includes calibration uncertainty, and long term stability (<30 Pa per year). Barometer range of 60 to 120 kPa.
[2] Combined linearity, hysteresis and repeatability. Add 3 Pa when used in gauge mode. When using the ADT160-01-APXXQ sensors
with the ADT780 controller in gauge mode, regular zeroing will realign the barometric reading to provide the most accurate result.
Electrical measurement specifications[1]
Specification
Volts DC
Current DC
Switch test
DC 24V output
Range
Resolution
Accuracy
±0,01% of reading
-30 to 30 V
0,1 mV
+ 1,5 mV
±0;01% of reading
-300 to 300 mV
1 µV
+ 15 μV
±0,01% of reading
-30 to 30 mA
0,1 µA
+ 1,5 μA
If the switch has detected voltage, the range is from 3 -24 V
24V ± 0,24V, max 30 mA
[1] not available in ADT780S version
Physical specifications
Specification
Power
Pressure ports
Storage temperature
Operating environment
Display
Weight
Dimensions (DWH)
Mounting
Schock
Vibration
ADT780-1K & ADT780-3K
100V - 240V, 50/60 Hz
G1/8 F
-20 °C to 70 °C
0-90% RH non-condensing
7 inch (17.8 cm) color, touch screen display
15 kg
419 x 440 x 132 mm
Standard desktop, optional rack mount
4G
1G 10Hz~500Hz
Other specifications
WiFi specifications
Vent
Communications
Stability indicator
Typical pressure control timee
Operating modes
Display modes
Localization
Conformity
Calibration certification
Warranty
802.11 b, g, and n
Front panel vent and safety release button (only for ADT 780S)
RS232, USB, LAN,WIFI
User selectable
typically 20 seconds
Control, measure, vent
Controller – shows pressure indication and control
Calibrator – shows pressure indication, control and electrical
measurement (excl. ADT780S)
English, German, Spanish, French, Italian, Portuguese, Russian,
Chinese (traditional and simplified), Japanese
CE
NIST traceable certificate of calibration with data included
DAkkS Certificate (optinal)
1 year
Standarrd accessories
s
ADT127-X external ma
anifold
1xx
Manifold cconnection cable
c
1xx
Pow
wer adapter
1xx
9022
2 test leads
2 sets (4 pieces)
9020 sho
ort circuit ca
able
1 set (2 p
pieces)
9060 pre
essure mod
dule
conne
ection cable
e
1xx
Adapter se
et (adapterss to fit
the ADT7
78X port to male
m
ffittings)
1xx
CD
D-Manual
1xx
NIST trace
eable certiifficate
1xx
O
O-rings
20xx
Vacuum
m / Vent tubing
2 pie ces
(DAkkS-Cerrtificate optional)
Optiona
O
ales Zub
behör
A
ADT160A
Pre
essure module
(see mo
mation)
odule inform
A
ADT121-X
External pneumatic pressure
manifold,, 200 bar, fo
our handtight q
quick conne
ectors
ADT780-1K-EPU
UMP
70 ba
ar electrical pump
9050
RS232
2 to USB ad
dapter
L
Liquid trap
Liquid trap
9
9907-780
Shipment case for the
e ADT780
controller
Ad
dditel/ Pcal
Acal
9
9245-780
ADT
T100-780-K
Kit
DAkkkS-Calibratiion
KK
Addite
el/ Pcal calib
bration
software
Automated
d calibration
n software,
task and asset management
Ra
ack mount kit
k
Adapter sset, X pcs, g1/8
g
M to
vario
ous connecttions
DA
AkkS-certific
cate
ADT160
A
0A intelligent digital
d
p
pressure
e modules
Specificati
S
ons
Precision Quartz Sensors
Gauge presssure Differe
ential pressurre
[1]. -
Abs
solute Pressure
e
Pressure Range
P/N
P
Pre
essure Range
Media
Accuracy
[2]
Burrst
press
sure
Overr
pressu re
Sugge
ested
Controller
Compattibility
Intternal /
Ex
xternal
Use
((psia)
(bara)
AP15R
0 to 15
0 to 1
Gas
0.01 % FS
2x
x
1.2x
ADT780-1K only
B
Both
AP30R
0 to 30
0 to 2
Gas
0.0
01 % rdg or 0.003 %
FS whichever is grreater
2x
x
1.2x
ADT780-1K only
B
Both
AP50R
0 to 50
0 to 3.5
Gas
0.0
01 % rdg or 0.003 %
FS whichever is grreater
2x
x
1.2x
ADT780-1K only
B
Both
AP1
100R
0 to 115
0 to 8
G&L
01 % rdg or 0.003 %
0.0
FS whichever is grreater
x
2x
1.2x
ADT780-1K only
B
Both
AP3
300R
0 to 315
0 to 21
G&L
0.0
01 % rdg or 0.003 %
FS whichever is grreater
2x
x
1.2x
Botth
B
Both
AP5
500R
0 to 515
0 to 36
G&L
01 % rdg or 0.003 %
0.0
FS whichever is grreater
x
2x
1.2x
Botth
B
Both
AP1KR
0 to 1,015
0 to 71
G&L
0.0
01 % rdg or 0.003 %
FS whichever is grreater
2x
x
1.2x
Botth
B
Both
AP2
2KQ
0 to 2,015
141
Gas
0.005 % rdg
S
+ 0.005 % FS
x
3x
1.1x
ADT780-3K only
B
Both
AP3
3KQ
0 to 3,015
201
Gas
0.005 % rdg
+ 0.005 % FS
S
3x
x
1.1x
ADT780-3K only
B
Both
Media
Accuracy
Sugge
ested
Controller
Compattibility
Intternal /
Ex
xternal
Use
Standard Pressure Sensors
Pressure Range
P/N
P
psi
bar g
Pre
essure Rating
Burrst
Overr
press
sure Pressu
ure
CP
P10
±10
±0.7
Gas
0,02 %FS
3x
x
1.2x
ADT780-1K only
B
Both
CP
P15
±15
±1.0
Gas
0,02 %FS
3x
x
1.2x
ADT780-1K only
B
Both
CP
P30
-15 to 30
-1 to 2.0
Gas
0,02 %FS
3x
x
1.2x
ADT780-1K only
B
Both
CP
P50
-15 to 50
-1 to 3.5
Gas
0,02 %FS
3x
x
1.2x
ADT780-1K only
B
Both
CP
P100
-15
5 to 100
-1 to 7.0
G&L
0,02 %FS
3x
x
1.2x
ADT780-1K only
B
Both
CP
P300
-15
5 to 300
-1 to 20
G&L
0,02 %FS
3x
x
1.2x
Botth
B
Both
CP
P500
-15
5 to 500
-1 to 35
G&L
0,02 %FS
3x
x
1.2x
Botth
B
Both
CP
P600
-15
5 to 600
-1 to 40
G&L
0,02 %FS
3x
x
1.2x
Botth
B
Both
CP
P1K
-15 to 1,000
-1 to 70
G&L
0,02 %FS
3x
x
1.2x
Botth
B
Both
CP
P2K
-15 to 2,000
-1 to 140
G&L
0,02 %FS
3x
x
1.2x
ADT780-3K only
B
Both
CP
P3K
-15 to 3,000
-1 to 200
G&L
0,02 %FS
3x
x
1.2x
ADT780-3K only
B
Both
CP
P5K
-15 to 5,000
-1 to 350
G&L
0,02 %FS
3x
x
1.2x
N/A
A
Exxternal
CP
P10K
-15 tto 10,000
-1 to 700
G&L
0,02 %FS
3x
x
1.2x
N/A
A
Exxternal
Note:
N
[1]. Conta
act europascal fo
or other range options.
o
[2]. Accura
acy includes ca
alibration uncerta
ainty, linearity a
and long-term sttability.
G=G
Gas / L = Liquid
**
* Low Pressure
e sensors (ADT160A-XX-DPX) availible for low
w pressure and differential pres
ssure measurem
ment. Also availible for low
pressure
p
contro
ol (gauge models only). Ranges
s ±1 inH20 (2,5 mbar) to 300 in
nH2O (700 mba
ar)
Sensor
S
spe
ecifications
s
Operating temperaturre
Storage ttemperature
e
Relative
e humidity
Pressure
P
co
onnections (for
(
externall use only)
Enclosure
E
(fo
or external use
o
only)
Dimensio
ons (Dia x H))
We
eight
Standard accuracy
CPX
XXX
-10°C to 50°C
-20°C to 70°C
95%
% RH
1/4NPT, 1/4B
BSP, 1/2BSP
P,
M20
0x15
Precission accuracy
AP3KQ AP2KQ
Q
APXXXR
A
15°C
1
to 25°C
C
10°C to 30°C
-200°C to 70°C
90% RH
1/4NPT,
1
1/4B
BSP, 1/2BSP
P, M20x15
SS en
nclosure
33 mm x 123 mm
0,4
4 kg
SS
S enclosure
44
4 mm x 220m
mm
0,8 kg
60 mm
m x 190 mm
m
0,7 kg
[1]
[ Internal senssors used to go inside the ADT780 nee d to ha
ave a M20 connection and conn
nection kit.
Electric
E
c pump
Additel
A
780
0-1K-EPUM
MP electric pump
 Gen
nerates from
m vaccum up to 70 bar
 Builtt-in filter and liquid trap
p
70
7 bar elec
ctric pump specificatiions
ra
Pressure
P
ange
-0,95 to75 bar
Weight
W
31,6 kg
Dimension
D
ns (WxHxD))
440 x 235 x 550 mm
Power
P
100 to 240V
Supply
S
Medium
clean air
Outlet
O
portt
G1/8F
tem
Storage
S
mperature
-20°C to 70
0°C
Operating
O
environme
ent
0 – 90% RH, non-cond
densing
Mounting
M
Standard desktop,
d
opttional 19” raack mountin
ng
Control
C
op
peration
2 LED disp
plays with pressure limiit settings