1 Safety instructions

Electrical equipment may only be installed and fitted by electrically skilled persons.

Failure to observe the instructions may cause damage to the device and result in fire and other hazards.

Danger of electric shock. Always disconnect before carrying out work on the devise or load. At the same time, take into account all circuit breakers that supply dangerous voltage to the device or load.

Danger of electric shock. Device is not suitable for disconnection from supply voltage.

Do not connect any electronic lamps, e.g. switchable or dimmable compact fluorescent lamps or LED lamps. Device can be damaged.

These instructions are an integral part of the product, and must remain with the end customer.

2 Device components

picture 1: Device components

(1) Dimmer

(2) Frame

(3) Central plate

(4) Adjusting knob

(5) Screw terminals

3 Function

Intended use

- Switching and dimming incandescent lamps and HV halogen lamps

- Installation in appliance box acc. to DIN 49073

- Suitable for mixed operation up to the specified output (see chapter 6.1. Technical data) i No operation with transformers.

32544943

J:0082544943

1/4 19.08.2010

Light Management

Rotary dimmer with 2-way push switch

Product characteristics

- Dimming principle, phase cut-off

- Soft locking on actuation

- Electronic short-circuit protection with permanent switch-off after 7 seconds at the latest

- Electronic over-temperature protection

- Changeover switch possible in combination with two changeover switches

- Power enhancement is only possible with the power extensions listed under Accessories i Flickering of the connected lamps due to undershoot of the specified minimum load or through centralised pulses from the power stations and soft humming due to the radio interference suppressor. These are not device faults.

4 Operation

Switch light o Press the control button.

Adjust the brightness

Light is switched on. o Turn the control button in the clockwise direction.

The light gets brighter up to maximum brightness. o Turn the control button in the anti-clockwise direction.

Light gets darker to minimum brightness.

5 Information for electrically skilled persons

5.1 Fitting and electrical connection

DANGER!

Electrical shock when live parts are touched.

Electrical shocks can be fatal.

Before working on the device, disconnect all the corresponding miniature circuit breakers. Cover up live parts in the working environment.

Connecting and mounting the dimmer picture 2: Connection diagram o Connect the dimmer (1) according to the connection diagram (picture 2).

32544943

J:0082544943

2/4 19.08.2010

Light Management

Rotary dimmer with 2-way push switch o Mount the dimmer in the accessory socket. o Mount the frame and the central plate. o Attach the adjusting knob.

Connection in changeover switch i No changeover switch possible with two dimmers. picture 3: Changeover switch

(1) Dimmer

(6) Changeover switch o Connect the dimmer (1) and the changeover switch (6) according to the connection diagram (picture 3).

6 Appendix

6.1 Technical data

Rated voltage

Mains frequency

Ambient temperature

Connected load at 25 °C

Incandescent lamps

HV halogen lamps

Power reduction per 5°C in excess of 25°C when installed in wooden or dry construction walls when installed in multiple combinations

Connection

Single stranded

AC 230 / 240 V ~

50 Hz

-5 ... +25 °C

100 ... 1000 W

100 ... 1000 W

-10 %

-15 %

-20 % max. 4 mm²

The symbols used to label the dimmer load shows the load type that can be connected to a dimmer and the electric behaviour of a load: R = ohmic

6.2 Troubleshooting

The device switches the load off and on again after some time.

Overheating protection has tripped.

Reduce the connected load.

32544943

J:0082544943

3/4 19.08.2010

Light Management

Rotary dimmer with 2-way push switch

Check the installation situation. i Automatic switch-on after cooling.

The device switches the load off and cannot be switched on again.

Short-circuit protection has tripped.

Eliminate short-circuit. i After elimination of the short circuit, automatic switch-on. Short-circuit protection is not based on a conventional fuse, no metallic separation of the operational current.

6.3 Accessories

TRONIC amplifier, built-in

Amplifier for conventional dimmers, built-in

Art.-No.: 247 EB

Art.-No.: 246 EB

6.4 Warranty

We reserve the right to make technical and formal changes to the product in the interest of technical progress.

We provide a warranty as provided for by law.

Please send the unit postage-free with a description of the defect to our central customer service office:

ALBRECHT JUNG GMBH & CO. KG

Service Center

Kupferstr. 17-19

D-44532 Lünen

Service-Line: +49 (0) 23 55 . 80 65 51

Telefax: +49 (0) 23 55 . 80 61 89 [email protected]

General equipment

Service-Line: +49 (0) 23 55 . 80 65 55

Telefax: +49 (0) 23 55 . 80 62 55 [email protected]

KNX equipment

Service-Line: +49 (0) 23 55 . 80 65 56

Telefax: +49 (0) 23 55 . 80 62 55 [email protected]

The Πsymbol is a free trade symbol, which is solely intended for the authorities and does not guarantee any properties.

ALBRECHT JUNG GMBH & CO. KG

Volmestraße 1

D-58579 Schalksmühle

Telefon: +49.23 55.8 06-0

Telefax: +49.23 55.8 06-1 89

E-mail: [email protected]

Internet: www.jung.de

www.jung-katalog.de

32544943

J:0082544943

4/4 19.08.2010

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement