Sibir (N-SR) S210GE User Manual
Sibir (N-SR) S210GE is a versatile refrigerator suitable for various settings, including homes, farms, cottages, and holiday homes. It offers convenient features like temperature regulation, ice-making capability, and defrosting functionality. You can choose to operate it on either mains electric or LP gas, providing flexibility in energy sources. Additionally, the S210GE includes adjustable storage racks, allowing you to customize the interior space to meet your needs. With its focus on practicality and convenience, this refrigerator aims to make food storage and preservation effortless.
PDF
Document
Advertisement
Advertisement
MANUAL S150 GE 822 70 57-02 S210 GE MO-M 0709 OPERATING AND INSTALLATION INSTRUCTIONS FOR REFRIGERATORS S150 GE and s210 GE INTRODUCTION CONTENTS We are pleased that you have chosen this refrigerator and hope you will derive much satisfaction from using it, but first a few well-meant words of advice: • It is important to read through these instructions carefully before using the refrigerator. • To ensure good refrigeration and economical operation, the refrigerator must be installed and used as described in these instructions. • The refrigerator is ideal for installation in homes, farms, cottages, holiday homes, and chalets or similar. OPERATING INSTRUCTIONS _ ________________ 4 CONTROLS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 STARTING THE REFRIGERATOR . . . . . . . . . . . . . . . . 4 REGULATING THE TEMPERATURE. . . . . . . . . . . . . . 4 FOOD STORAGE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 ICE-MAKING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 TRANSIT DAMAGE DEFROSTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Inspect the refrigerator for damage. Transit damage must be reported to whoever is responsible for delivery not later than seven days after the refrigerator was delivered. CLEANING THE REFRIGERATOR. . . . . . . . . . . . . . . . 5 S210GE - positioning the storage racks. . . 5 DATA PLATE TURNING OFF THE REFRIGERATOR. . . . . . . . . . . . . 5 Check the data plate, inside the refrigerator, to ensure that you have received the right model. iF THE ‘FRIDGE FAILS TO WORK . . . . . . . . . . . . . . . 5 The right gas pressure is ........................... 30 mbar The right voltage is ........................... 120 volt MAINTENANCE_____________________________ 5 SOME USEFUL HINTS. . . . . . . . . . . . . . . . . . . . . . . . . 5 The data plate contains e. g. the following details: Model designation ..................................... Product number ..................................... Serial number ..................................... TECHNICAL DATA___________________________ 6 INSTALLATION INSTRUCTIONS________________ 6 Since these details will be needed if you have to contact service personnel, it is a good idea to make a note of them here. PLACEMENT OF THE REFRIGERATOR. . . . . . . . . . . 6 LP GAS CONNECTION. . . . . . . . . . . . . . . . . . . . . . . . . 6 ELECTRICAL CONNECTION . . . . . . . . . . . . . . . . . . . . 6 OPERATING INSTRUCTIONS REGULATING THE TEMPERATURE The position number refers to fig. 1. It will take several hours for the refrigerator to reach normal operating temperature. A thermostat controls the temperature of the main compartment of the refrigerator. The thermostat knob (B) should be set at 3-5. If a lower (colder) temperature is desired set the thermostat to a higher figure. CONTROLS FOOD STORAGE • Always keep food in closed containers. Never put hot food in the refrigerator; allow it to cool first. • Never keep items in the refrigerator that might give off flammable gases. • The frozen food compartment is intended for the storage of frozen food and for making ice. It is not suitable for freezing items of food. • Never put bottles or cans of fizzy drinks in the frozen food storage compartment as they may burst when freezing. • Most kinds of frozen food can be stored in the frozen food compartment for about a month. This period of time may vary, however, and it is important to follow the instructions on the individual packets. FIG. 1 ICE-MAKING The refrigerator can be run on either mains electric or LP gas. Changing between these modes of operation is carried out by means of control buttons positioned as shown in fig. 1. Fill the ice tray just below the brim with drinking water and place it on the freezer shelf. It is possible to make ice faster by turning the control knob temporarily to its highest value but do not forget to turn it back to its regular setting afterwards as the refrigerator might otherwise become too cold. The energy selector (A) can be set at either I (= 120 V), (= LP gas) or 0. The refrigerator temperature is controlled by a thermostat (B). Please note that the thermostat has no “off” position. DEFROSTING Frost will gradually accumulate on the refrigerating surfaces. It must not be allowed to grow too thick as it acts as an insulator and adversely affects refrigerator performance. Check the formation of frost regularly every week and when it gets about 3 mm thick, defrost the refrigerator. To defrost the refrigerator, turn it off and remove the ice tray and all food items. Warning: normally the temperature of items of frozen foods would rise unduly during defrosting so they should be consumed within 24h or discarded. Do not try to accelerate defrosting by using any kind of heating appliance, as this might damage the plastic surfaces of the refrigerator. Neither should any sharp objects be used to scrape off the ice. Defrost water runs from a collector channel to a receptacle at the rear of the refrigerator where it evaporates. Defrost water in the freezer compartment should be mopped up with a cloth. When all ice has melted, wipe the refrigerator dry and restart it. Place the food items back inside but wait until the refrigerator is cold before making ice cubes. The refrigerator is fitted with a safety device that automatically shuts off the supply of gas if the flame goes out. The safety device can be opened manually by pressing the button (C). The piezoelectric igniter discharges sparks over the burner when the button (D) is pressed. In the flame viewer (E) you can see a blue light when the gas flame is lit. STARTING THE REFRIGERATOR The position numbers refer to fig. 1. LP Gas operation After initial installation, servicing, or changing gas cylinders etc., the gas pipes may contain some air, which should be allowed to escape by briefly turning on the refrigerator or other appliances. This will ensure that the flame lights immediately. 1. Make sure that all valves between the gas container and the refrigerator are open. 2. Turn the energy selector (A) to position . . Push the button (C) in until it reaches the bottom - and hold, push the button (D) for the piezo igniter several times to light the burner. . Check the flame indicator (E) to see if the flame is lit. 5. Keep the button (C) pressed for a further 10-15 seconds. 6. Release the button (C) and check that the flame is alight. To terminate gas operation, turn knob (A) to 0. Electric operation Set the energy selector (A) to position I . CLEANING THE REFRIGERATOR TURNING OFF THE REFRIGERATOR Clean the inside of the refrigerator regularly to keep it fresh and hygienic. Soak a cloth in a solution consisting of a teaspoon of bicarbonate of soda to half a litre of warm water. Wring out the cloth and use it to clean the interior of the refrigerator and its fittings. Never use detergents, scouring powder, strongly scented products or wax polish to clean the interior of the refrigerator as they may damage the surfaces and leave a strong odour. The exterior of the refrigerator should be wiped clean now and again, using a damp cloth and a small quantity of detergent. But not the door gasket, which should only be cleaned with soap and water and then thoroughly dried. The cooling unit behind the refrigerator should be cleaned with a brush from time to time, but make sure that the refrigerator is switched off when doing this. If the refrigerator is not to be used for some time: 1. Shut off any valve in the gas line to the refrigerator. 2. Set the energy selector (A) to 0. . Empty the refrigerator. Defrost and clean it as described earlier. Leave the door(s) of the refrigerator and the frozen food compartment ajar. iF THE ‘FRIDGE FAILS TO WORK Before calling a service technician, check: • That the STARTING THE REFRIGERATOR instructions have been followed. • The refrigerator is level. • If it is possible to start the refrigerator on any of the connected sources of energy. • If the refrigerator fails to work on gas, then check: • That the gas bottle is not empty. • That all LP-gas valves are open. • If the refrigerator fails to work on mains electric, then check: • That the mains electric supply is connected to the refrigerator. • That the fuse is intact. S210GE - positioning the storage racks Dismanling/mounting 1. Loosen the front and back securing brackets. If the refrigerator is not cold enough it may be because: • The ventilation of the cooling unit is inadequate; see the paragraph PLACEMENT OF THE REFRIGERATOR. • The evaporator is frosted up. • The temperature control setting is incorrect. • The gas pressure is incorrect - check the pressure regulator at the gas container. • Too much food is loaded at one time. • The door is not properly closed or the magnetic sealing strip is defective. 2. Move the storage rack to the left (1), tilt up/down (2) and remove. If the refrigerator still does not work properly, call a service technician. 1 The sealed cooling system must not be opened, since it contains corroding chemicals under high pressure. 2 MAINTENANCE Inspect the gas hose periodically for cracks or deep chafing marks. Connections can be tested for leaks using a soap solution. DO NOT USE AN OPEN FLAME! If there is any suspicion of damage, call for a service technician. We recommend that a service technician check the refrigerator once a year. . To fit the storage rack, mount in reverse order. SOME USEFUL HINTS Make sure that: • Defrosting is carried out periodically. • The refrigerator is clean and dry with the door left open when it is not to be used for some time. • Liquids or items with a strong odour are well packaged. • There is a free air circulation over the cooling unit at the rear of the refrigerator. TECHNICAL DATA LP GAS CONNECTION S150 GE The refrigerator is designed for operation on LP gas, the pressure of which must be 30 mbar for Propane. Check that this is stated on the data plate. S210 GE Overall dimensions Height 1175 1612 mm Width 592 592 mm Depth 623 623 mm Gross 146 224 litres Net 137 209 litres 15 47 litres 58 76 kg Input 120 V 195 325 watt Energy consumption/24h 2.2 3.9 kWh The refrigerator is not designed for operation on town gas or natural gas. Check that the gas supplied to the refrigerator is at the correct pressure. See the reducing valve on the LP gas container. Capacity frozen food compartment Weight (without packaging) The gas installation and servicing should only be carried out by an authorized, qualified person and must conform to all relevant national and local regulations. The gas supply system must incorporate a pressure regulator to maintain a supply pressure of not more than 30 mbar. A wall-mounted or floor-mounted shutoff valve of an approved bottled-gas type must be incorporated in the supply line in a position which is readily accessible to the user. If a hose connection is used, only hoses of the approved type must be used. The gas inlet tube should be connected at the rear to the connection provided and be well secured with hose clamps. All completed connections should be checked for leaks with soapy water. DO NOT use a flame to check for gas leaks. Electrical data LP gas data Input max 0.33 0.48 kW Energy consumption/24h 400 500 g Cooling medium Ammonia Sodium chromate is used for corrosion protection (less than 2 weight % of the coolant). ELECTRICAL CONNECTION INSTALLATION INSTRUCTIONS The electrical installation must be carried out in a proper and durable manner; taking into accounts all relevant regulations and codes of practice. This appliance must be installed by an authorised person and conform to all relevant authorities. For mains voltage operation, it is important that the circuit is effectively earthed. PLACEMENT OF THE REFRIGERATOR 120 volt connection The room should have a capacity (length x width x height) of at least 20 m3 and must be adequately ventilated as well as follow all relevant national and local regulations. Further the room should have a window (which can be opened) or a door to the outside. It is important that the refrigerator is not subject to radiation of heat from a stove etc. For best performance, also at high ambient temperatures, there must be a free air circulation over the cooling unit at the rear of the refrigerator. The refrigerator is designed for a free-standing installation and the clearance to the rear wall and to possible side walls, should be at least 25 mm. The clearance above the refrigerator should be at least 100 mm. The refrigerator must be adjusted to a vertical position in both directions. Use the feet on the refrigerator to adjust its position. From the side Check that the voltage stated on the data plate is the same as the mains voltage in use. Plug the refrigerator power cord into an easily accessible earthed wall socket. Electrical leads must be routed and secured so that they cannot come into contact with hot or sharp parts of the refrigerator. Lighting The refrigerator is provided with a battery power interior light. The battery box is at the rear of the refrigerator. Four batteries, type LR20 1,5 volts are to be used. From above Wall 25 25 Rear 25 At least 25 mm Wall Sibir International AB www.sibir.com ">
/
Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement